IPS INTELLIGENT PUMP STARTER
|
|
- Melvyn Griffith
- 5 years ago
- Views:
Transcription
1 IPS INTELLIGENT PUMP STARTER The IPS Intelligent Pump Starter features SMARTSTART motor protection, integrated electronic pump protection overload, and power metering and data logging options. Ø & Ø, 0/60 Hz, 20~AC, /2~00 hp INTEGRATED TRU-POWER ELECTRONIC PROTECTION Eliminates need for costly pump protection relays Dry pump detection using power (nuisance trip-free); time-based automatic restart and well recovery mode Features a wide-range, adjustable, class -0 electronic overload Provides superior motor protection from the following conditions: Over/Under power (dry-run) Over/Under voltage protection Voltage phase loss Voltage and current phase unbalance Stalled/locked rotor Cycle fault Ground fault (UL 0 certified) Voltage phase reversal BUILT-IN POWER MONITORING AND FAULT LOGGING View voltage, current, power factor, and more through an intuitive display Quickly identify common power problems such as phase imbalance, voltage drop, and over/under current conditions to ensure proper pump operation Built-in fault log, counter and parameter change log: records last fault types with power condition values, stores how many times each fault type has occurred (up to 2 count), and logs changes to parameter settings (e.g. FLA, OV/UV, under power) TRU-POWER SENSING Tru-power sensing protects pumps from dry-run, dead head, run-out, and jammed impeller conditions - keeping you online and preventing costly premature pump failure. Along with superior protection, measuring underload using power allows for a more flexible trip range, as opposed to measuring by current, which requires a more precise set point. The end result is the elimination of nuisance trips. POWER NO LOAD FULL LOAD CURRENT NO LOAD NOTE: Power is linear for superior load monitoring FULL LOAD 2
2 IPS INTELLIGENT PUMP STARTER EASY TO SET-UP AND USE Inside, the display shows an easy to use menu for setting a wealth of parameters. Adjust any protective or control setting in seconds. For example, choose how long to allow for dry well recovery, set run time periods, and on/off delays. All this with just a few intuitive keystrokes. The IPS ships with factory default settings pre-programmed for optimal submersible pump protection. INDUSTRIAL GRADE CONSTRUCTION Door mounted heavy-duty HOA switch Housed in an outdoor rated, gasketed, NEMA R enclosure Multi-tap control power transformer with integrated secondary protection accommodates common motor voltages. No fuses required! Includes 20 VAC control power for field devices NEMA/IEC rated magnetic contactors feature 2. million electrical cycles at full rated current ADVANCED PROGRAMMABLE PUMP CONTROL Automatic fault reset Backspin delay - Prevents start-up while system is draining On and off delay settings Well recovery mode (up to 8 hours) Minimum run time based on last input 2-20 V input for remote start/stop Dry contact input for remote start/stop The internal keypad and LCD make the IPS intuitive and versatile. Parameters are easily changed and faults are clearly displayed. Standard control features include a 2-20 V auto run input (irrigation control system, etc.), shutdown terminal for applications such as a low level float switch, and more. The multi-tap power transformer accepts inputs of 200 V, 20 V, and 60 V STANDARD CIRCUIT BREAKER DISCONNECT* UL 89 circuit breaker provides branch and short circuit protection No fuses required saves time and money Lockable handle for safety *Service entrance rated. OPTIONAL ETHERNET CARD Download and display up to 00 faults and alarms, including operational mode and values of operation at the time of fault All power condition values are stored by phase for voltage, current, and power factor per fault Data is easily displayed and saved on any web browser using an Ethernet connection. The IPS incorporates internal web-server. No additional software required Time- and date-stamped for utility documentation
3 IPS INTELLIGENT PUMP STARTER - ORDERING & SIZING INFORMATION IPS (20~60 VAC) - & -Phase, 0/60 Hz, 20~60 VAC, NEMA Type R Enclosed - Combination Starter. Includes Service Entrance Circuit Breaker Disconnect. 200 V - 60 V -PHASE SFA RANGE** (A) -PHASE HP (UL) / MA. FLA** -PHASE HP (UL) / MA. SFA** 20 V 200 V 20 V 60 V HP SFA HP SFA HP SFA HP SFA HP SFA IPSR-S-J-G 6~ IPSR-S-J-G20 8~ IPSR-S-J-G0 ~ IPSR-S-J-G0 6~ IPSR-SP-J-G0 20~ IPSR-SP-J-G60 2~ IPSR-S2-J-G80 2~ IPSR-S-J-G00 0~ IPSR-S-J-G2 0~ IPSR-SP-J-G0 60~ IPSR-S-J-G200 80~ IPSR-S-J-G20 00~DPV* IPSR-S-J-G00 20~ IPSR-S-J-G00 60~ IPSR-S-J-G00 20~ IPSR-SP-J-G600 20~ IPSR-SP-J-G800 20~DPV* *DPV = Differs per voltage **Use SFA Range or Max. SFA when sizing for submersible motor applications. If an amperage value for SFA is not published on the motor nameplate, consider SFA range to be FLA range. IPS W/ ETHERNET FAULT LOGGING (20~60 VAC) - & -Phase, 0/60 Hz, 20~60 VAC, NEMA Type R Enclosed - Combination Starter. Includes Service Entrance Circuit Breaker Disconnect. -PHASE HP (UL) / 200 V - 60 V MA. FLA** -PHASE HP (UL) / MA. SFA** -PHASE SFA 20 V 200 V 20 V 60 V RANGE** (A) HP SFA HP SFA HP SFA HP SFA HP SFA IPSR-S-J-G-E 6~ IPSR-S-J-G20-E 8~ IPSR-S-J-G0-E ~ IPSR-S-J-G0-E 6~ IPSR-SP-J-G0-E 20~ IPSR-SP-J-G60-E 2~ IPSR-S2-J-G80-E 2~ IPSR-S-J-G00-E 0~ IPSR-S-J-G2-E 0~ IPSR-SP-J-G0-E 60~ IPSR-S-J-G200-E 80~ IPSR-S-J-G20-E 00~DPV* IPSR-S-J-G00-E 20~ IPSR-S-J-G00-E 60~ IPSR-S-J-G00-E 20~ IPSR-SP-J-G600-E 20~ IPSR-SP-J-G800-E 20~DPV* *DPV = Differs per voltage **Use SFA Range or Max. SFA when sizing for submersible motor applications. If an amperage value for SFA is not published on the motor nameplate, consider SFA range to be FLA range. +
4 IPS INTELLIGENT PUMP STARTER - ORDERING & SIZING INFORMATION IPS (AC) -Phase, 0/60 Hz, AC, NEMA Type R Enclosed - Combination Starter. Includes Service Entrance Circuit Breaker Disconnect. -PHASE HP (UL) / MA. SFA** -PHASE SFA RANGE** (A) HP SFA IPSR-S-6J-G 6~8 8 IPSR-S-6J-G20 8~ 0 IPSR-S-6J-G0 ~7 7 IPSR-S-6J-G0 6~ IPSR-S-6J-G0 20~ IPSR-S2-6J-G60 IPSR-S2-6J-G80 2~ 2~ IPSR-S-6J-G00 0~7 0 7 IPSR-S-6J-G2 0~ IPSR-S-6J-G0 60~ IPSR-S-6J-G200 IPSR-S-6J-G20 80~ 00~ IPSR-S-6J-G00 IPSR-S-6J-G00 20~70 60~ IPSR-SP-6J-G00 IPSR-SP-6J-G600 20~28 20~ ** Use SFA Range or Max. SFA when sizing for submersible motor applications. If an amperage value for SFA is not published on the motor nameplate, consider SFA range to be FLA range. IPS W/ ETHERNET FAULT LOGGING (AC) -Phase, 0/60 Hz, AC, NEMA Type R Enclosed - Combination Starter. Includes Service Entrance Circuit Breaker Disconnect. -PHASE HP (UL) / MA. SFA** -PHASE SFA RANGE** (A) HP SFA IPSR-S-6J-G 6~8 8 IPSR-S-6J-G20 8~ 0 IPSR-S-6J-G0 ~7 7 IPSR-S-6J-G0 6~ IPSR-S6J-G0 20~ IPSR-S2-6J-G60 IPSR-S2-6J-G80 2~ 2~ IPSR-S-6J-G00 0~7 0 7 IPSR-S-6J-G2 0~ IPSR-S-6J-G0 60~ IPSR-S-6J-G200 80~ 00 IPSR-S-6J-G20 00~2 2 2 IPSR-S-6J-G00 IPSR-S-6J-G00 20~70 60~ IPSR-SP-6J-G00 IPSR-SP-6J-G ~28 20~ ** Use SFA Range or Max. SFA when sizing for submersible motor applications. If an amperage value for SFA is not published on the motor nameplate, consider SFA range to be FLA range. OPTIONS (FACTORY INSTALLABLE) DESCRIPTION IPS--PH WIRING FOR SINGLE-PHASE MOTOR (REQUIRED FOR Ø, NO COST) IPS-MODBUS* MODBUS RTU COMMUNICATIONS CARD IPS-SRG20 SURGE SUPPRESSOR, 200/20 V IPS-SRG80 SURGE SUPPRESSOR, 60 V IPS-SRG600 SURGE SUPPRESSOR, IPS-RPL RUN PILOT LIGHT, GREEN IPS-FPL FAULT PILOT LIGHT, RED IPS-SPB START PUSH BUTTON CONTROL IPS-STSP START/STOP PUSH BUTTON CONTROL (IN LIEU OF HAND/OFF/AUTO SWITCH) IPS-2 2 VAC CONTROL CIRCUIT (IN LIEU OF 20 VAC CONTROL CIRCUIT) *Cannot be installed on IPS with ethernet fault logging
5 IPS INTELLIGENT PUMP STARTER - DIMENSIONS & WIRING DIAGRAM DIMENSIONS STARTER H W D IPSR-S-J-G IPSR-SP-J-G IPSR-S2-J-G IPSR-S-J-G 22 0 IPSR-SP-J-G IPSR-S-J-G IPSR-S-J-G IPSR-SP-J-G 62 2 NOTE: All dimensions in inches W H D WIRING DIAGRAM IPS PCB A CAT Input CON A2 COIL PWR Dry Inputs Relay Outputs Voltage Inputs Actuator Control Common D Hand D2 Auto D Status O2 Common O Fault O V Auto Run V V2 Shut Down V Motor A2 Limit Switch A Common A 2-20VAC/DC Input 20VAC, 0.2A Output JDS N.O. Input See Table DM L L2 L MCCB H H A B C OL GND CAT Output SURGE SUPPRESOR TABLE STANDARD - HOA SWITCH Common OFF H A Hand Auto IPS-SPB OFF H A Common CPT 20V To V/V Auto Run N *See Notes & JAR V 2-20VAC/DC Auto Run Input V Auto Run CON L T T L2 T2 T2 L T T 2 Hand Auto IPS-STSP STOP Common START 208V 20V 80V H2 M Hand START TRANSFORMER PRIMARY CIRCUIT BREAKER SIZING PH Auto H H VA V 208/ VA N/A N/A 00VA A A NOTES: Standard wiring schematic shown. Actual product wiring may vary depending on options selected. Dashed lines indicate field wiring. Checked boxes indicate factory installed options. Remove jumper JDS to wire limit switch. When jumper jar is present, terminals V & H2 act as connections for a normally open, dry contact, auto run input. Remove jumper jar to use V & V terminals as a voltage, auto run input. Apply 2~20 VAC/DC to energize. 6
6 IPS INTELLIGENT PUMP STARTER - SPECIFICATIONS SPECIFICATIONS Inputs Outputs Operational Settings Adjustments Hand/Off/Auto Voltage Auto Dry Contact Auto Shutdown Actuator Position Switch Status Relay Fault Relay Actuator Power Overload Type Power Fail Modes On/Off Time Delay Fault Reset Ambient Operating Temp Ambient Storage Temp Relative Humidity STARTER TYPE Combination - Service rated, suitable for use as a service disconnect NEMA Type R Enclosed USER INTERFACE Internal Door mounted -position switch STANDARD CONTROL OPERATIONS Accepts 2-0 VAC/DC. Applying voltage will send a run command to the starter when in auto mode. Normally open dry contact. When closed, the starter will be commanded to run when in auto mode. Accepts 2-0 VAC/DC. Applying voltage will open the contactor and the starter will not accept a run command Hand/Off/Auto LEDs will flash. Normally open dry contact. To be used in series with customer provided actuator contacts which disable the motor starter until the actuator is in position. (i.e. The contactor will not close unless this contact is closed) Normally open relay contact, 2 VAC, 2 VAC Normally open relay contact, 2 VAC, 2 VAC 20 VAC, 0.2A max. Electronic, I2T trip curve Restart in last mode (Hand/Off/Auto) with no delay (default) Restart in off mode Restart in off mode if power failure lasts longer than 2 seconds. Restart in last mode if power failure is less than 2 seconds. On/Off, adjustable: seconds Adjustable: Manual or automatic (default differs per motor protection feature) ENVIRONMENTAL - F to 0 F (-20 C to 60 C) - F to 8 F (-20 C to 8 C) % to 9% non-condensing MOTOR PROTECTION ADJUSTMENT / DESCRIPTION DEFAULT SETTING Overload Current Setting Range Differs per model Per SFA Overload Trip Class Adjustable: -0 0 Overload Service Factor Adjustable: Under Power On/Off, adjustable: 0-99% of measured electrical input On / 60% Over Power On/Off, adjustable: 0-200% of measured electrical input On / 20% Over/Under Voltage On/Off, adjustable: +-2% over/under the nominal voltage setting On / 0% Voltage Phase Unbalance On/Off, adjustable: -20% voltage phase deviation On / % Voltage Phase Loss Always on, adjustable: -0% voltage phase deviation 0% Voltage Phase Sequence Reversal On/Off, trips within 0. seconds upon voltage phase reversal detection On Ground Fault (UL 0 Certified) On/Off, adjustable:.0-9.9a On / A Cycle Fault On/Off, adjustable: Trip if cycle rate exceeds 20 starts/minute On Warm Start Provision On/Off, delays motor restart based on calculated motor temperature On SMARTSTART PROTECTION ADJUSTMENT / DESCRIPTION DEFAULT SETTING Current Phase Unbalance On/Off, adjustable: -0% current phase unbalance On / % Locked Rotor / Stall On/Off, trips within 0. seconds On Out of Calibration On/Off, trips after 0 seconds if the FLA dial setting is incorrect (set above calculated FLA range), i.e. start current is outside of an acceptable range (FLA setting * < in-rush < FLA setting * ). On Max Time to Start On/Off, regardless of FLA or I2T curve, always trip at start if starting current is outside of an acceptable range (in-rush / ) and still decreasing after 0 seconds. On 7
EMS 1Ø, 120 ~ 230V, 1/10-25HP 3Ø, 200 ~ 600V, 1/2-300HP
ES, 120 ~ 230V, 1/10-25HP, 200 ~ 600V, 1/2-300HP ENERGY ANAGEENT STARTER T Smartstart THE OST INTELLIGENT STARTER YET Power metering, optional BACnet or odbus communications, and an intuitive interface
More informationENERGY MANAGEMENT SOFT-STARTER THE MOST INTELLIGENT SOFT-STARTER YET
ES-RV 3Ø, 208 ~ 480V, 2-250HP ENERGY ANAGEENT SOFT-STARTER THE OST INTELLIGENT SOFT-STARTER YET Retaining the incredible features from the original ES such as Power metering & odbus RTU communications,
More informationSmartstart Control Module
Smartstart TECHNOLOGY What is Smartstart? The patented Smartstart control module is an integrated, seamless solution that incorporates operator control, superior motor protection, and automation system
More informationSMARTSTART MOTOR STARTERS
SMARTSTART MOTOR STARTERS MCG WWW.MCG-USA.COM 1 AT A GLANCE Covers all line voltages from 200-600V AC, single or three phase Transformer supplies a 24V AC coil voltage, no matter the line voltage 12V AC/DC
More informationFRANKLIN CONTROL SYSTEMS HVAC SMART STARTERS
FRANKLIN CONTROL SYSTES HVAC SART STARTERS BUD CLARK COONS Location: Portland, OR FCS Product: ES Starters YOU LL FIND FCS STARTERS IN THE WORLD S SARTEST PROJECTS. Project Spotlight: Bud Clark Commons
More informationPump Data Sheet - Patterson HVAC Pumps Company: Intermountain Hydron Name: Cache County Mountain Crest Date: 09/24/2018
Pump Data Sheet - Patterson HVAC Pumps Company: Intermountain Hydron Name: Cache County Mountain Crest Date: 09/24/2018 Tags: P-8 1800RPM Premium Efficient Motor 460/3/60 Pump and Motor Weight: 183lbs
More informationSECTION SOLID-STATE REDUCED VOLTAGE STARTERS
SECTION 26 29 13.16 PART 1 - GENERAL 1.1 THE REQUIREMENT A. General: The CONTRACTOR shall provide solid-state reduced voltage motor starters, complete and operable, in accordance with the Contract Documents.
More informationMODELS DPDT DPDT DPDT-60MS DPDT-60MS
INSTALLATION INSTRUCTIONS Revision B1 Rapid City, SD, USA, 03/2010 MODELS 201-100-DPDT 201-200-DPDT 201-100-DPDT-60MS 201-200-DPDT-60MS II_201-XXX-DPDT_B1 II-201-DPDT-B BE SURE POWER IS DISCONNECTED PRIOR
More informationSP SP-T-9
INSTALLATION INSTRUCTIONS Revision B1 Rapid City, SD, USA, 04/2010 MODELS 201-100-SP 201-200-SP 201-200-SP-T-9 II_201-SP_B1 2880 North Plaza Drive, Rapid City, South Dakota 57702 (800) 843-8848 (605) 348-5580
More informationSED2 Variable Frequency Drives with Electronic (E) Bypass Options
SED2 Variable Frequency Drives with Electronic (E) Options Description The E- Options are companion packages for the family of SED2 Variable Frequency Drives (s). For information on the family of SED2
More informationBT300 HVAC Drives Electronic Bypass (E-Bypass) Options
BT300 HVAC Drives Electronic Bypass (E-Bypass) Options Description The BT300 Electronic Bypass (E-Bypass) Options are companion packages for the family of BT300 Variable Frequency Drives (VFDs). For information
More informationSED2 Variable Frequency Drives Conventional Bypass (C-Bypass) Options
Submittal Sheet SED2 Variable Frequency Drives Conventional Bypass (C-Bypass) Options Description The Bypass Options are companion packages for the family of SED2 Variable Frequency Drives. For information
More informationPowerFlex 400 AC Drive Guide Specification
PowerFlex 400 AC Drive Guide Specification Adjustable Frequency Drives with Bypass 3.0 50HP @ 208V AC 3.0 350HP @ 480V AC PART 1 GENERAL 1.01 Quality Assurance A. The manufacturer shall have minimum 5
More informationS.W. Version SubMonitor Connect Installation & Operation Manual
S.W. Version 7.003 SubMonitor Connect Installation & Operation Manual Safety Instructions As with all electrical products, read the manual thoroughly before operating. Only qualified personnel should
More informationQ-LINK SMART BYPASS. SIZING INFORMATION TABLE Q-Link Variable Frequency Drive - 3-Phase 208 VAC 230 VAC VAC HP FLA HP FLA HP FLA TECHNOLOGIES
Q-LINK SMRT BYPSS 1 28, 208 480VC, 3Ø UL Type 1 Enclosure The is an integrated solution for critical applications without compromising for communications and motor protection. Unlike traditional bypasses,
More information4/8/ nd Annual OTCO WW Workshop W/WW Product Overview ACQ550. ABB Slide 1
4/8/2015 52 nd Annual OTCO WW Workshop W/WW Product Overview ACQ550 Slide 1 Drive Basics Why Use Adjustable Speed Drives? Reduced Energy Consumption Improved Process Control / Efficiency Increased Product
More informationOVERLOAD RELAYS POWER & ACTUATION PROVEN. series
POWER & ACTUATION OVERLOAD RELAYS series Need reliable, accurate overload and phase-loss protection for your motors? c3controls Series Bimetallic Overload Relays provide unmatched protection and can be
More informationCurrentWatch Current Sensors. EGF Series Ground Fault Sensors. Ground Fault Sensors with Solid-State or Mechanical Relay Outputs.
CurrentWatch Current Sensors Ground Fault Sensors with Solid-State or Mechanical Relay s 1 Contents Overview.................... 1 Model Selection, Switches...... 2 Model Selection, Accessories... 3 Wiring
More informationBE SURE POWER IS DISCONNECTED PRIOR TO INSTALLATION! FOLLOW NATIONAL, STATE AND LOCAL CODES! READ THESE INSTRUCTIONS ENTIRELY BEFORE INSTALLATION.
INSTALLATION INSTRUCTIONS FOR SYMCOM S MODEL 777-ACCUPOWER w/4-20ma POWER MONITOR MOTOR PROTECTION RELAY OVERLOAD RELAY BE SURE POWER IS DISCONNECTED PRIOR TO INSTALLATION! FOLLOW NATIONAL, STATE AND LOCAL
More informationStandard Options. Model 4100 Position Indicating Meter. Three Phase Motor Control. Positran Transmitter
Standard Options Model 4100 Position Indicating Meter A percent-of-full-travel meter is supplied with a trim potentiometer resistor, terminal block and connectors. A potentiometer is required in the actuator
More informationMetering Devices, Protective Relays, Software and Connectivity. Pre-Wired Control Power, Voltage and CT Inputs
.3 Features and Benefits Saves installation time and cost One part number to order; no need to worry that any part has been left out Pick the meter or meters you need as it is designed to fit various Eaton
More informationSED2 VFD NEMA Type 3R Bypass/Air Conditioner
SED2 VFD NEMA Type 3R Bypass/Air Conditioner Description The NEMA Type 3R Bypass with Air Conditioner allows SED2 to be employed in a harsh environment. The SED2 is designed specifically for HVAC applications
More informationINSTALLATION INSTRUCTIONS. Revision C1 Rapid City, SD, USA, 02/2010 MODEL ALT-XXX-3-SW
INSTALLATION INSTRUCTIONS Revision C1 Rapid City, SD, USA, 02/2010 MODEL ALT-XXX-3-SW II-ALT-XXX-3-SW-B BE SURE POWER IS DISCONNECTED PRIOR TO INSTALLATION! FOLLOW NATIONAL, STATE AND LOCAL CODES. READ
More informationPHASE MONITOR RELAYS Product Summary
Product Summary Phase Monitor Relays provide protection against premature equipment failure caused by voltage faults on 3 Phase systems. All Macromatic Phase Monitor Relays are designed to be compatible
More informationE1 Plus Electronic Overload Relay
ROCKWELL AUTOMATION PROCUREMENT SPECIFICATION PROCUREMENT SPECIFICATION E1 Plus NOTICE: The specification guidelines in this document are intended to aid in the specification of products. Specific installations
More informationMSR Level Control Relay Module Operating Instructions for Level Control Relay Module Model: MSR
Operating Instructions for Level Control Relay Module Model: MSR MSR Operation Instructions Rev. Apr 07 Page 1/8 1. Note Please read and take note of these operating instructions before unpacking and commissioning.
More informationLM10 to MM200 Retrofit
Grid Solutions LM10 to MM200 Retrofit Replace old LM10 Motor Controller relays with the Multilin TM MM200 Motor Management System The LM10 Motor Controller (discontinued in 2013) has been replaced by new
More informationPowered to Perform. Everyday Reliability. Exceptional Value. Expertise and Support
A decentralized solution. Many drive applications utilize control panels with complex wiring taking up large amounts of space. These control panels are often mounted away from the application requiring
More informationFTA750 LIMITED SERVICE FIRE PUMP CONTROLLERS STANDARD SUBMITTAL PACKAGE
FTA750 LIMITED SERVICE FIRE PUMP CONTROLLERS STANDARD SUBMITTAL PACKAGE SBP750-51(B) FTA750 Full Voltage Starting Limited Service Electric Fire Pump Controllers Product Description Description Firetrol
More informationFire Pump Controllers Jockey Pump Controllers
Fire Pump Controllers Jockey Pump Controllers Jockey Pump Controllers 1.7 Jockey Pump Controllers XTJP Jockey Pump Controllers - Feature Sheet... XTJP Dimension Drawings... XTJP Wiring Diagrams - 3 Phase...
More informationBaltimore Aircoil Company
Baltimore Aircoil Company VFD Startup Guide TABLE OF CONTENTS: A. Verifying Power and Control Wiring...1 B. Setting the VFD Parameters...2 C. Reentering Startup Wizard After Initial Setup...5 D. Starting
More informationCompact Coded Magnetic Safety Interlock Switch and Control Units
C Conforms to EN292, EN60204-1, EN954-1, EN1088, EN60947-5-3, EN947-5-3, EN50081, EN50082, EN61000-6-2 UL and C-UL listed, TUV certified Description R US Compact Coded Magnetic Safety Interlock Switch
More informationTrident and Trident X2 Digital Process and Temperature Panel Meter
Sign In New User ISO 9001:2008 Certified Quality System Home Products Online Tools Videos Downloads About Us Store Contact Policies Trident and Trident X2 Digital Process and Temperature Panel Meter Products
More informationLOW HARMONIC DRIVE U1000
DRIVES LOW HARMONIC DRIVE U1000 INTELLIGENT PUMP CONTROL U1000 iqpump THE NEW U1000 iqpump Intelligent. Efficient. Compact. We ve combined our award-winning Matrix low harmonic power structure with the
More informationQuantum III. Compact DC Drive Package. Slitter DC Drive Package. Quantum III
Compact DC Drive Package The delivers a DC drive package that integrates the intelligence of the Mentor II with a space saving design that incorporates many accessories typically required in the North
More informationStandard SureVolt Power Conditioner / Voltage Regulator
Utility Systems Technologies, Inc. P.O. Box 110 Latham, NY 12110 Standard SureVolt Power Conditioner / Voltage Regulator Introduction The SureVolt electronic voltage regulator / power conditioner provides
More informationSECTION ( ) LIGHTING CONTROL PANELBOARD
(26 24 16.02) LIGHTING CONTROL PANELBOARD PART 1 GENERAL 1.01 SCOPE A. The Contractor shall furnish and install Lighting Control Panelboards as specified and as shown on the contract drawings. B. The Lighting
More informationSECTION SWITCHBOARDS
SECTION 26 24 13 PART 1 - GENERAL 1.1 SUMMARY A. Work Included: 1. Switchboards 2. Commercial Metering Switchboards 3. Non-Utility Power Meters (Microprocessor-Based Metering Equipment) PART 2 - PRODUCTS
More informationQuick Start Guide TS A
Quick Start Guide TS 930 125-630A DANGER HAZARD OF ELECTRICAL SHOCK, EXPLOSION, OR ARC FLASH Read and understand this quick start guide before installing and operating the transfer switch The installer
More informationFLÄKTGROUP OFFERS A WIDE RANGE OF PER- MANENT MAGNET MOTORS (PM) AND FREQUENCY CONVERTERS FOR PLUG FANS. POWER RANGE IS FROM 0,8 KW TO 15 KW.
CENTRIFLOW PUR 3D (A, PLUG B, C, D) FAN GMPM FC101 AND SLIDE IN FREQUENCY ROTOR CASSETTE CONVERTER QUICK GUIDE FLÄKTGROUP OFFERS A WIDE RANGE OF PER- MANENT MAGNET MOTORS (PM) AND FREQUENCY CONVERTERS
More informationSTANDARD SUBMITTAL PACKAGE
STANDARD SUBMITTAL PACKAGE SBP1000-51( ) FTA1000 Full Voltage Starting Electric Fire Pump Controllers Product Description Description Firetrol FTA1000 Full Voltage Fire Pump Controllers are intended for
More informationPump-Down Controller MODEL mA Input Scalable 4-20mA Output Duplex Pump Alternation Hand-Off-Auto Controls Dual Run-time Meters
DESCRIPTION Pump-Down Controller Input Scalable Output Duplex Pump Alternation Hand-Off-Auto Controls Dual Run-time Meters The Model 4052 Pump-Down Controller provides total control for duplex pumping
More informationVLT 2800 DRIVE SPECIFICATIONS
VLT 2800 DRIVE SPECIFICATIONS Drive Input Power Input voltage 3 phase... 200 through 240, or 380 through 460; 3-phase all ratings 200 through 240, 1-phase through 2 HP Input voltage range for full output...
More informationQCPort Cover Control Trouble Shooting Guide
QCPort Cover Control Trouble Shooting Guide Technical Document Feb. 2006 Page 1 of 14 QCPort Cover Control Description Door Defeater Address/Options Bucket Latch Breaker Actuator Hasp Lock Keypad Overlay
More informationJK Series POWER DISTRIBUTION. Solid State Starters Medium Voltage A
POWER DISTRIBUTION JK Series Solid State Starters Medium Voltage 200-400-600-720A SOLID STATE STARTER JKSSS4+ Series The JKSSS Series of motor starter is the result of extensive research and development.
More informationSED2 Variable Frequency Drives
Building Technologies SED2 Variable Frequency Drives More standard features Means better control of HVAC applications The global leader in Heating, Ventilation and Air Conditioning (HVAC) products and
More informationFor normal duty, design the VFD voltage level at 480 Volt, 3 Phase, 60 Hertz. (In Canada, 600 Volt, 3 Phase, 60 Hertz.)
Introduction The Variable Frequency Drive Design Guidelines provides design criteria and specifications used in the procurement and application of variable frequency drives (VFDs). Table of Contents 1.
More informationPART 1: GENERAL PART 2: PRODUCT. Effective: 12/29/10 Page 1 of 6 FECA-TE-104D
Specification Number: 23 09 33 Product Name: FRENIC-Eco AC Drives for Variable Torque Fan & Pump Applications (1-125Hp at 208/230V and 1-900Hp at 460V) PART 1: GENERAL 1.01 SUMMARY A. This specification
More information9/7/2010. Chapter , The McGraw-Hill Companies, Inc. MOTOR SYMBOLS. 2010, The McGraw-Hill Companies, Inc.
Chapter 2 MOTOR SYMBOLS 1 Symbols are used to represent the different components of a motor control system. Symbols sometimes look nothing like the real thing, so we have to learn what the symbols mean.
More information12-36 VDC/12-24 VAC Power Option 4-Digit Display, 0.56 (14.2 mm) or 1.20 (30.5 mm)
4-20 ma & Relay Output Features 4-20 ma, ± 10 V, TC & RTD Inputs 12-36 VDC/12-24 VAC Power Option 4-Digit Display, 0.56 (14.2 mm) or 1.20 (30.5 mm) 24 VDC @ 200 ma Transmitter Power Supply Options Type
More informationEnclosed DOL Motor Starter Type 4x, Plastic, 3-Phase
Enclosed DOL Starter Type x, Plastic, Phase C US LISTED ENCLOSED INDUSTRIAL CONTROL PANEL WIRING SPECIFICATIONS CONTROL/COIL VOLTAGE: LINE (LINE) START/STOP (STSR) START STOP //8 //8 Customer Supplied
More informationWiring Diagrams UNITS WITH STARTING SERIAL NUMBER 3507Q
AQUASNAP 30RB060-390 Air-Cooled Liquid Chillers with COMFORTLINK Controls 60 Hz Wiring Diagrams UNITS WITH STARTING SERIAL NUMBER 3507Q INDEX* POWER SCHEMATICS 30RB Unit Size Voltage Figure Number Label
More informationFor full product information, visit Use the SpeedSpec code or scan the QR Code for quick access to the specific web page.
R Safety Monitoring Relays For full product information, visit www.sti.com. Use the SpeedSpec code or scan the QR Code for quick access to the specific web page. Dual-Channel Safety Monitoring Relay Power
More informationEnclosed Non-Reversing Combination Controller, AC Operation - Type 1/12K/IP66 ➏➐. Non-Metallic Type 1/12K/IP66 Enclosure (KS7-C0C4R)
KWIKstarter/CX7 CX7 Non-Reversing Combination Controller, AC Enclosed Non-Reversing Combination Controller, AC Operation - Type 1/12K/IP66 ➏➐ Catalog Number ➍➏➑➒ ~ ~ ~ ~ 0.10 0.16 2.1 1 CX7-9-10- -AS0.16A-A10-PG
More informationA drive dedicated to variable speed control for HVAC applications
A drive dedicated to variable speed control for HVAC applications Designed for easy installation in mechanical fan and pump systems with reliable connectivity to building automation networks. VTAC 9 Drive
More informationINTEGRATED AUTOMATION ACTUATORS AND OPERATORS
25 34 13.13 - PART 1 - GENERAL 1.1 THE REQUIREMENT A. The CONTRACTOR shall provide complete Valve Actuators and Operators as shown on the drawings, control diagrams, herein, or in other Sections of the
More informationSECTION DISCONNECT SWITCHES
SECTION 16440 DISCONNECT SWITCHES PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and other Division 01 Specification
More informationMAJOR VA Power Inverter
MAJOR500-500 VA Power Inverter The Major500 is a highly reliable, telecom quality, DC to AC power inverter. The Major500 features full electronic protection, high efficiency and low output noise. The built-in
More information(1986; Rev. 1989) Molded Case Circuit Breakers and Molded Case Switches. (1985; Rev. 1988) Enclosures for Electrical Equipment (1000 Volts Maximum)
Section 16306 50/60-HERTZ (HZ) SOLID STATE FREQUENCY CONVERTER Index PART 1 GENERAL PART 2 PRODUCTS 1.1 References 2.1 Frequency Converters 1.2 Factory Tests 2.2 Conduit and Fittings 1.3 Submittals 2.3
More informationSED2 Variable Frequency Drives
SED2 Variable Frequency Drives Startup Procedure and Checklist Document No. 155-718 Table of Contents Prerequisites...1 Preparing for SED2 VFD Startup...1 HVAC Startup Procedure for SED2 with Bypass Option...4
More informationAIR COOLED MODULAR RECTIFIER
CONTROLLED POWER COMPANY SPECIFICATIONS AIR COOLED MODULAR RECTIFIER Spc1800a1 5JAN1999 SPECIFICATION S-1800-A MODULAR (REMOVABLE AND NON-REMOVABLE MODULES) AIR COOLED RECTIFIER Standard output power range:
More informationAND OPTIONAL ACCESSORIES
USER S GUIDE Revision A Rapid City, SD, USA, 11/2010 MODEL 777-KW/HP-P2-DEMO AND OPTIONAL ACCESSORIES POWER MONITOR II_KW/HP-P2-DEMO_A 2880 North Plaza Drive, Rapid City, South Dakota 57702 8242 Loop Rd.
More informationJockey Pump Controllers
BR081001EN Microprocessor Based with Color Touchscreen Product Description ACROSS THE LINE Controllers operate across-the-line. Full voltage is applied to the motor for starting by the use of a single
More informationOperating Instructions. For. Level Control Module. Model SSR 1000
Operating Instructions For Level Control Module Model SSR 1000 SSR Operation Instructions Rev. 1 Jan 01 Page 1/7 1. Note Please read and take note of these operating instructions before unpacking and commissioning.
More informationControls Enclosed Non-Combination Starters - PESW Series
NEMA 4/4X Non Metallic Enclosure Product Features WEG offers non-reversing and non-combination NEMA-4X magnetic starter up to 75HP at 460V. Featuring components that meet IEC design standards and UL horsepower
More informationGS1 and GS2 Series AC Drives
GS1 and GS2 Series AC Drives Single Phase In 3 Phase Out Simple communications Each drive has a built-in Modbus RTU RS-485 communications port (RS-232/485 configurable on the GS2 series). An optional Ethernet
More informationSpecification Sheet For electronically commutated motors
SC-VAV-N Specification Sheet For electronically commutated motors Used in constant pressure applications The SC-EFC is designed to control exhaust air in various building applications. The system includes
More informationGE Power Management. MMII Intelligent MCC Controller
A concept that will offer reduced overall installed cost and production efficiency through information availability to operators and maintenance. Presentation Overview 6 Applications 6 Protection and Control
More informationSupplementary operating instructions for your air curtain system Controller TMC 500
Supplementary operating instructions for your air curtain system Controller TMC 500 (Translation of the original) Serial number: Year: Please quote this number when contacting customer service! Date 08.04.2016
More informationLine A. Inverse parallel scrs. Load a FUSION. Line B SCR POWER. O delta CONTROLLERS. Line c. inverse parallel scrs. Load C. FUSION Brochure Rev 3.
Line A Inverse parallel scrs Load a Line B FUSION SCR POWER O delta CONTROLLERS Line c inverse parallel scrs Load C FEATURES Auto-Ranging Input Voltage 24-600 VAC, 45-65 Hz AC or DC Output AC Models: 50-1200
More informationSECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS
SECTION 262816 - ENCLOSED SWITCHES AND CIRCUIT BREAKERS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division
More informationETM MD100 Drive System 1/2HP (370W) User Manual. Table of Contents. Drive Features
Table of Contents Drive Features... 1 Drive Specifications... 2 Certifications... 3 Installation - Drive Dimensions... 3 Motor Dimensions (mm)... 4 Drive Mounting... 4 Wiring... 5 I/O Terminals... 9 Menu...
More informationAPPLICATION CONTROL GUIDELINES. IntelliROL Power Supply PN Revision Date: March 15, 2017
APPLICATION CONTROL GUIDELINES IntelliROL Power Supply PN 1176718 Revision Date: March 15, 2017 Table of Contents List of Tables...3 TGW Safety Recommendation...4 Warnings and Safety Instructions...5 Introduction...6
More informationPC-200-LLC-GM INSTALLATION INSTRUCTIONS. Revision A1 Rapid City, SD, USA, 10/2009 II_PC-XXX-LLC-GM_A1
INSTALLATION INSTRUCTIONS Revision A1 Rapid City, SD, USA, 10/2009 MODELS PC-100-LLC-GM PC-200-LLC-GM II_PC-XXX-LLC-GM_A1 2880 North Plaza Drive, Rapid City, South Dakota 57702 (800) 843-8848 (605) 348-5580
More informationMicroVersaTrip Plus & MicroVersaTrip PM Conversion Kits for Allis Chalmers Power Circuit Breakers
MicroVersaTrip Plus & MicroVersaTrip PM Conversion Kits for Allis Chalmers Power Circuit Breakers Easily replace electro-mechanical trip units with the latest electronic, digital trip unit technology Ensure
More informationINSTRUCTIONS FOR MODEL 1000 DIGITAL PROCESS INDICATOR AND ALARM
INSTRUCTIONS FOR MODEL 1000 DIGITAL PROCESS INDICATOR AND ALARM LOVE CONTROLS DIVISION Dwyer Instruments, Incorporated PO Box 338 Michigan City, IN 46361-0338 (800) 828-4588 (219) 879-8000 FAX (219) 872-9057
More informationINSTALLATION DKM-409 NETWORK ANALYSER WITH HARMONIC MEASUREMENT AND SCOPEMETER. Before installation:
DKM-409 NETWORK ANALYSER WITH HARMONIC MEASUREMENT AND SCOPEMETER The DKM-409 is a precision instrument designed for displaying various AC parameters in 3-phase distribution panels. Thanks to its isolated
More informationRX Series. MotorProtection/OverloadRelay ,000VAC,1through2000A ADVANCEDINSTALLATION,OPERATION COPYRIGHT2016 ALLRIGHTSRESERVED,MOTORTRONICSINC.
MOTORTRONICSTM SolidStateACMotorControl RX Series MotorProtection/OverloadRelay 200-15,000VAC,1through2000A ADVANCEDINSTALLATION,OPERATION &PROGRAMMING MANUAL COPYRIGHT2016 ALLRIGHTSRESERVED,MOTORTRONICSINC.
More informationPLT. Breaker-based transfer switch open, closed or soft transition amps. Specification sheet
Specification sheet PLT Breaker-based transfer switch open, closed or soft transition 800 3000 amps Description PLT breaker-based transfer switches are designed for operation and switching of electrical
More informationMETERING/DISPLAY MANUAL
METERING/DISPLAY MANUAL 175W - 750W SINGLE PHASE Series LV EMERGENCY LIGHTING CENTRAL INVERTER Myers Power Products, Inc. 44 South Commerce Way, Bethlehem, PA 18017 1-800-526-5088 (610) 868-3500 Fax: (610)
More informationInstallation, Operation and Maintenance Manual
Document 481200 VGD-100 Vari-Green Drive Installation, Operation and Maintenance Manual Please read and save these instructions for future reference. Read carefully before attempting to assemble, install,
More informationSoft Starter Remote Operator. Section 1.0 Introduction 1.1 Important user information General Manual description...2.
Section 1.0 Introduction 1.1 Important user information... 2 1.2 General... 2 1.3 Manual description...2 Contents Section 2.0 Specification 2.1 General technical data...3 2.2 Dimensions...3 Section 3.0
More informationJockey Pump Controllers
BR081001EN Microprocessor Based with Color Touchscreen Product Description ACROSS THE LINE Controllers operate across-the-line. Full voltage is applied to the motor for starting by the use of a single
More informationMulti-Point Gas Detection and Control System
Multi-Point Gas Detection and Control System DESCRIPTION Wall mounted, microprocessor-based, multi-point, analog electronic control system for various gas, temperature and humidity detection, control and
More informationNew Solutions. for AC Motor Starters
ADAPTABILITY RELIABILITY CREATIVITY New Solutions for AC Motor Starters Featuring : Electronic Centrifugal Switches for Capacitor Start (Capacitor Run) Motors / Digital Motor Starters for Three Phase Bidirectional
More information160 AA02SF1 AF DS-D17
Ordering Instructions The Standard Packaged Drive Program allows users to create drive packages based on their specific needs. A complete drive package may be specified by assembling a single catalog number
More informationPG Softstarter Installation Manual for 5A, 9A and 16A Controllers
PG Softstarter Installation Manual for 5A, 9A and 16A Controllers Important User Information The examples and diagrams in this manual are included solely for illustrative purposes. Because of the many
More informationInstallation Manual for D244X Series 24-volt Power Supplies
Installation Manual for D244X Series 24-volt Power Supplies D2441-B D2441-C D2443-B D2443-C D2445-B D2445-C D2400 Series 1A 24 volts 1A 24 volts 3A 24 volts 3A 24 volts 5A 24 volts 5A 24 volts Dycon Power
More informationEnclosed Non-Reversing Combination Controller, AC Operation - Type 1/12K/IP66 ➏➐ (KS7-C0C4R) Discount Schedule F-1
KWIKstarter/CX7 CX7 Non-Reversing Combination Controller, AC Enclosed Non-Reversing Combination Controller, AC Operation - Type 1/12K/IP66 ➏➐ ~ ~ ~ ~ 0.10 0.16 2.1 1 CX7-9-10- -AS0.16A-A10-PG 551 Q4 ~
More informationSSW06. Soft Starters. Applications. Standard Features. Pumps Fans Blowers Compressors Crushers Saws Grinders Mixers.
General Information CFW10 CFW100 CFW08 CFW500 CFW700 CFW701 CFW11 EDP11 CFW11M SSW05 SSW07 GPH2 TPH2 The is WEG s third generation Soft Starter line. The keypad, with dual display, has red LED digits which
More informationInstallation Manual Updated May 2017
Code No. LIT-12012114 Installation Manual Updated May 2017 JC-VSD Factory Packaged (FP) Series II drive frames 4 8, Type 1 and 3R Johnson Controls variable speed drives Disclaimer of warranties and limitation
More informationHigh Voltage DC Meter
High Voltage DC Meter Javelin D PD644 0-300 VDC input NEMA 4X, IP65 front Scale in engineering units Sunlight readable LED display 4-20 ma analog output Two form C 3 A relays option RS-485 serial communications
More informationMicroVersaTrip Plus & MicroVersaTrip PM Conversion Kits for Westinghouse Power Circuit Breakers
MicroVersaTrip Plus & MicroVersaTrip PM Conversion Kits for Westinghouse Power Circuit Breakers Easily replace electro-mechanical trip units with the latest electronic, digital trip unit technology Ensure
More informationPowerFlex 40 Sample Specification
PowerFlex 40 Sample Specification GENERAL REFERENCES REGULATORY REQUIREMENTS Designed to meet the following specifications: NFPA 70 - US National Electrical Code NEMA ICS 3.1 - Safety standards for Construction
More informationIMS Control & EPR, We keep your motors running ABB s new control & protection devices up to 18.5 kw / 20 hp
IMS Control & EPR, 2010 01 29 We keep your motors running ABB s new control & protection devices up to 18.5 kw / 20 hp October 27, 2010 1SBC101089D0201 ABB s new control and protection devices Up to 18.5
More informationTECHNICAL BROCHURE BCPNEMAST R0. NEMA Rated Three-Phase Starters BY EATON
TECHNICAL BROCHURE BCPNEMAST R0 NEMA Rated Three-Phase Starters BY EATON STANDARD FEATURES Series ECN - NEMA Rated Three-Phase Starters Adjustable Electronic Overloads C440 Series - Adjustable Class, Bi-metallic,
More informationFUSION COMPACT. Load a. Line A. Inverse parallel scrs. Line B. Line c. inverse parallel scrs. Load C SCR POWER. O delta CONTROLLERS
Line A Inverse parallel scrs Load a Line B COMPACT SCR POWER CONTROLLERS O delta Line c inverse parallel scrs Load C 1 Compact Brochure Rev 3.51 www.ccipower.com 1-800-765-2799 FEATURES Auto-Ranging Input
More informationQ9 ASD LOW VOLTAGE DRIVE
ASD LOW VOLTAGE DRIVE HVAC-MINDED, SYSTEM FRIENDLY RELIABLE Toshiba has manufactured pulse-width modulated drives since 1981 and is one of the few companies that manufactures both motors and drives in
More informationProduct Description. Table of Contents
Product Providing users with easy installation in mechanical fan and pump systems, the Allen-Bradley PowerFlex 400 AC drive offers a wide range of built-in features allowing for seamless building system
More informationSSW06. Soft Starters.
The is WEG s third generation Soft Starter line. The keypad, with dual display, has red LED digits which provide visibility and make programming easier. Integral bypass contacts eliminate heat dissipation
More information