INSTRUCTION MANUAL. Card Revision: Software 2.1 Card Revision: Hardware B(2.0) DOCUMENT SES-KS-2422-E REV. 3

Size: px
Start display at page:

Download "INSTRUCTION MANUAL. Card Revision: Software 2.1 Card Revision: Hardware B(2.0) DOCUMENT SES-KS-2422-E REV. 3"

Transcription

1 2422 DIGITAL OUTPUT CARD 16 CHANNELS INSTRUCTION MANUAL Card Revision: Software 2.1 Card Revision: Hardware B(2.0) DOCUMENT SES-KS-2422-E REV. 3

2 2422 DIGITAL OUTPUTS CARD 16 CHANNELS SES-ASA ENGINEERING INSTRUCTION MANUAL Information and relevant technical data contained in this manual are Copyrighted and property of SES ASA ENGINEERING SRL. This manual and relevant drawings cannot be used for purpose of manufacturing anything represented, nor disclosed to third parties without written approval of SES ASA ENGINEERING SRL. SES ASA ENGINEERING SRL will protect its own rights with legal means. SES ASA ENGINEERING SRL reserves the right to modify specifications and drawings without notice. WARRANTY SES ASA ENGINEERING SRL guarantees all of its products are free from manufacturing defects for a period specified in each data sheet or agreed upon with the customer. SES ASA ENGINEERING SRL will repair or replace at its workshop, free of charge, every instrument found to be defective during the warranty period. Technical personnel of SES ASA ENGINEERING SRL will determine the cause of damage. In any case the warranty is restricted to the cost of the instrument supplied by SES ASA ENGINEERING SRL. The customer will take the responsibility for any improper use of the instrument carried out by own or authorized personnel. page 2 of INSTRUCTION MANUAL - SES-KS-2422-E Rev. 3

3 SES-ASA ENGINEERING 2422 DIGITAL OUTPUTS CARD 16 CHANNELS TABLE OF CONTENTS 1. INTRODUCTION GENERAL BLOCK DIAGRAM SPECIFICATIONS SPECIFICATIONS OF BOARD MECHANICAL SPECIFICATIONS BOARD RACK ELECTRICAL SPECIFICATIONS BOARD POWER REQUIREMENTS O.C. OUTPUT AUXILIARY SIGNALS 0,1A MAX), FOR EACH CHANNEL: RELAY OUTPUT SIGNALS OPERATING CONDITIONS INSTALLATION HANDLING AND SHIPPING INSTALLATION OPERATIVE INSTRUCTIONS OPERATION CONNECTOR CONNECTIONS TO THE FIELD SETTING AND OPERATION OF OPEN COLLECTORS AUXILIARY OUTPUTS FRONT KEYBOARD PROCEDURES EXECUTABLE FROM THE FRONT PANEL FLOW DIAGRAM OF FRONT KEYBOARD OPERATING MODES USE OF HAND-HELD MONITOR TEST UNIT DIGITAL OUTPUTS CHECK AND TEST READING OF CHANNEL STATUS (ENABLED / DISABLED) READING OF CHANNEL STATUS (FLASH / NO FLASH) BOARD CONFIGURATION SWITCH SETTING TABLE JUMPER SETTING TABLE TYPICAL CONNECTIONS MAINTENANCE GENERAL STORAGE DIAGNOSTICS BOARD DIAGNOSTICS DIAGNOSTICS OF POWER SUPPLIES AND MICROPROCESSOR TROUBLESHOOTING CARD LAYOUT INSTRUCTION MANUAL - SES-KS-2422-E Rev. 3 page 3 of 24

4 2422 DIGITAL OUTPUTS CARD 16 CHANNELS SES-ASA ENGINEERING 1. INTRODUCTION 1.1. General Control unit 2422, a component of the F&G/ESD 2000 series, is designed for management and control of 16 digital output lines (24V dc negative logic, 0.1 Amp for each output line). The output card is designed to have negative logic characteristic in that it sinks current from the load to the user common power bus. The output devices are connected between the positive power bus (24V dc I/O) and the card outputs on the I/O connector. The output characteristics are compatible with a wide range of user-supplied field devices, such as: relays, LED s, lamps, etc. The single-chip microprocessor present on the 2422 card and in the entire 2400 series receives output command signals (On or OFF value) from the main processor mod Facility Module which execute the dedicated logic output (Application Program) and places the updated values in the output table of the 2422 card via a serial line command. The output table of this card is regularly updated over the serial line by the Facility module, using proprietary communication software through high speed RS 485 serial line. When a logic fault is detected the 2422 microprocessor communicates a fault status message to the Facility module, which immediately performs a fault table update reading and initiates the fault status commands. On the front card panel are placed double LED s which provide the ON/OFF status of each output point, serial line LED s which displays the communication condition and LED s which displays the watch-dog card condition and push-buttons which permits the execution of local commands. The board also allows management of 8 Open Collector auxiliary outputs for additional activation, which can be configured for flashing or not flashing operating mode. To increase the operating safety of the control unit the logical section (including microprocessor, serial interfaces and internal power supplies) is galvanicly isolated from the input/output circuits to/from the field. A complete self-diagnostics, made possible by a microprocessor, allows supervision and check of all the functionality of on-board components and correct operation of internal power supplies. In case of failure the corresponding Watchdog output will be deactivated. The board is fitted with a 32-pin DIN I/O connector. page 4 of INSTRUCTION MANUAL - SES-KS-2422-E Rev. 3

5 SES-ASA ENGINEERING 2422 DIGITAL OUTPUTS CARD 16 CHANNELS 1.2. Block Diagram 2422 INSTRUCTION MANUAL - SES-KS-2422-E Rev. 3 page 5 of 24

6 2422 DIGITAL OUTPUTS CARD 16 CHANNELS SES-ASA ENGINEERING 2. SPECIFICATIONS 2.1. Specifications of Board 2422 Application: activation of relays, lamps, LED s, etc., with a maximum load of 30Vdc per channel. N. of Channels: 16 Open Collectors Digital Outputs 8 Open Collectors Auxiliary Outputs Operating Environment: Warranty: Safe area 2 years of uninterrupted operation Mechanical Specifications Board Size: Double Euro elongated 6 HE std. 19 Front Width: Weight: Height: Length: 5 TE 420 g 233 mm 220 mm Rack Size: Weight: Standard 19 6 HE 2600 g Width: 482,6 mm - 19 Height: 266 mm - 10,47 Depth: 283 mm - 11,14 page 6 of INSTRUCTION MANUAL - SES-KS-2422-E Rev. 3

7 SES-ASA ENGINEERING 2422 DIGITAL OUTPUTS CARD 16 CHANNELS 2.3. Electrical Specifications Power Supply: 24Vdc Nominal (20 30Vdc) Fuse: 24Vdc ISO line: 500mA, retarded 24Vdc I/O line: 500mA, retarded Board Power Requirements Internal absorption: 24 V dc ISO line: Quiescent: 35 ma Alarmed: 66 ma Total max consumption: 1,6W max 24 V dc I/O line: Quiescent: 0 ma Alarmed: 35 ma + field adsorption Total max consumption: 0,9W max + field absorption O.C. Output Auxiliary Signals 0,1A Max), for each channel: Eight generic signals manageable from Facility 2401 through internal serial line (AUX O.C.1 AUX O.C.8) Relay Output Signals Common and N.O. contacts for watchdog signal with capacity for resistive loads: - 0,3 125/250 Vac - 0,3 125 Vdc Vdc Note: the relay is normally energised Operating Conditions Operating Temperature: Storage Temperature: Environment Humidity: 0 C + 70 C (+32 F +158 F) -40 C + 85 C (-40 F +185 F) 0 95% not condensing. 2.5 Front Panel Indications For each channel: Common: Redundant LED (red) for activation indication (OUT) Redundant LED (red) for serial line transmission (TX) Redundant LED (red) for serial line reception (RX) Redundant LED (yellow) for Watch Dog (WD) active 2422 INSTRUCTION MANUAL - SES-KS-2422-E Rev. 3 page 7 of 24

8 2422 DIGITAL OUTPUTS CARD 16 CHANNELS SES-ASA ENGINEERING 3. INSTALLATION 3.1. Handling and Shipping Every piece of equipment supplied by SES ASA ENGINEERING SRL is packed in order to prevent physical damage. Carefully check the contents of any package when received. Any noticed inconsistency should be communicated to SES ASA ENGINEERING SRL within ten days from material reception. SES ASA ENGINEERING SRL will not be liable for any damage if this communication is not forwarded within the indicated terms. Any claims for any damage will be communicated in written form also to the carrier. Any written communication must include product model and serial number Installation Although 2400 modules are built to be free from electromagnetic interference s, they should be installed in a place away from EMR sources such as motors, RF equipment, etc. Connection cables must be totally shielded and have a drain wire. The shield should be connected only to the safety panel end. If the modules are installed in enclosed places (cabinets), the maximum heat sink in accordance with available space should be considered, in order to avoid excessive overheating. A suitable ventilation system may have to be considered. SES ASA ENGINEERING SRL is at your complete disposal in supplying qualified experienced staff with the knowledge to review the plant feasibility. page 8 of INSTRUCTION MANUAL - SES-KS-2422-E Rev. 3

9 SES-ASA ENGINEERING 2422 DIGITAL OUTPUTS CARD 16 CHANNELS 4. OPERATIVE INSTRUCTIONS 4.1. Operation At start up of board 2422 the microprocessor inhibits outputs and displays on front panels so that the undetermined logical status s present at start up does not force any undesired activation or signal. Then the card address settings of dipswitch is read. After a waiting time of 5, the board enters its operating status accomplishing these functions: - Interfacing with the field - Display of field activation - Activation (in accordance with the programmed logic) of digital and auxiliary (if enabled) outputs; enabling front panel signals relative to active channels and Watchdog. To set these operating modes, please refer to section INSTRUCTION MANUAL - SES-KS-2422-E Rev. 3 page 9 of 24

10 2422 DIGITAL OUTPUTS CARD 16 CHANNELS SES-ASA ENGINEERING Connector Connections to the Field Note: the watchdog relay is normally energised; so, during normal operation, this contact will be closed (open in case of internal fault). page 10 of INSTRUCTION MANUAL - SES-KS-2422-E Rev. 3

11 SES-ASA ENGINEERING 2422 DIGITAL OUTPUTS CARD 16 CHANNELS 4.2. Setting and Operation of Open Collectors Auxiliary Outputs The Open Collector auxiliary outputs available on connector are 8 and can be activated in two different operating modes, depending on controlled devices: FLASHING AND NO FLASHING. The deactivation of these outputs will be executed when the cause of their activation disappears and by RESET command (on the Facility 2401 card front side) ending the ISA procedure. Operating modes, FLASHING and NO FLASHING, are managed by program software resident on the 2401 CPU Facility card memory INSTRUCTION MANUAL - SES-KS-2422-E Rev. 3 page 11 of 24

12 2422 DIGITAL OUTPUTS CARD 16 CHANNELS SES-ASA ENGINEERING 4.3. Front Keyboard page 12 of INSTRUCTION MANUAL - SES-KS-2422-E Rev. 3

13 SES-ASA ENGINEERING 2422 DIGITAL OUTPUTS CARD 16 CHANNELS Procedures Executable from the Front Panel These procedures can be activated through the front panel pushbuttons: 1. Channel shutdown (permanent inhibition) 2. Test. Channel shutdown (permanent inhibition) a) Press button SEL (SELection); the LED OUT of selected channel will flash. Press and release button SEL until the LED s of the channel to inhibit are flashing. b) Press button INH (INHibit); fast flashing of LED (about 5,4Hz) indicates the actual inhibition. Restore of Inhibited Channel a) PRESSES SEL button until the LED OUT of the channel to be restored are flashing asynchronously. b) Press INH button; the LED of that channel will flash slowly, indicating that the same channel is operating again. Note: If the channel selection procedure is not completed within 20 seconds from depression of the last button, the system automatically sets to NORMAL operation. Card inhibition will remain active till the card is powered on. After a power shutdown, the channels will be active at system powering on. Test Pressing TEST button all of front panel LED s (TX, RX, WD excluded) will flash for about 5 seconds, in order to check their state INSTRUCTION MANUAL - SES-KS-2422-E Rev. 3 page 13 of 24

14 2422 DIGITAL OUTPUTS CARD 16 CHANNELS SES-ASA ENGINEERING Flow Diagram of Front Keyboard Operating Modes Note: To select channel CHi presses i times button SEL. page 14 of INSTRUCTION MANUAL - SES-KS-2422-E Rev. 3

15 SES-ASA ENGINEERING 2422 DIGITAL OUTPUTS CARD 16 CHANNELS 4.4. Use of Hand-Held Monitor Test Unit 2490 Test unit 2490 allows access to some special operating modes not manageable from the board front controls. This device, powered and controlled by the board, is automatically configured when the 25-pin connector is inserted in the special receptacle on the front panel. After connecting the Hand-Held Monitor the initialisation message is displayed: SES-ASA 2422 r 2.2 (resident software revision number) Card Address 000 (board addressing number from 000 to 254) HAND HELD MONITOR OUT DIS FLSH and these functions are available: Card address check Digital outputs check and test Reading of channel status (enabled-disabled) and reading of flashing output status Digital outputs check and test 1. From the main menu, press function key F1. The display will show this message: MODIFICATION Chn: Out: * * Aux: * * ννννννν indicating the condition of the 16 digital output channels and of the 8 auxiliary channels. 2. If the channel has been activated, supervision bit should be *. If the output channel has not been activated (no field activation), supervision bit should be blank. The same procedure is valid for the auxiliary outputs. It is also possible to modify each status to force output activation. 3. Select moving the cursor ( _ ) with arrows and the bit corresponding to the output channel status, which can be modified using keys yes and no. Keys and are used for row selection. It s possible to activate or deactivate each output (OUT or AUX) just typing the number of the relative channel (two digits, e.g. 04 ). If the changed data is not compatible with the selected output, the HHM will show ERROR message. 4. Press Enter to return to the main menu. The menu will automatically return to main menu after 30 of inactivity INSTRUCTION MANUAL - SES-KS-2422-E Rev. 3 page 15 of 24

16 2422 DIGITAL OUTPUTS CARD 16 CHANNELS SES-ASA ENGINEERING Reading of channel status (Enabled / Disabled) 1. From the main menu, press function key F2. The display will show this message: DISABLE Chn: Out: * * Aux: * * ννννννν Each bit represents the status of each channel. If the bit is set to * the state is DISABLED, if it s blank the state is ENABLED. This function is only for channel status visualisation; the modification of the status is possible only with the programming software or, temporary, using the front panel pushbutton. This solution lasts only till the card is powered on. 2. Press Enter to return to the main menu. The menu will automatically return to main menu after 30 of inactivity Reading of channel status (Flash / No Flash) 1. From the main menu, press function key F3. The display will show this message: FLASH Chn: Out: * * Aux: * * ννννννν Each bit represents the status of each channel. If the bit is set to * the state is FLASH (when the channel is activated, it will switch from ON and OFF status with a frequency of 1 Hz). If the bit is blank the state is NO FLASH (the activated channel will be steady ON). This function is only for channel status visualisation; the modification of the status is possible only with the programming software Press Enter to return to the main menu. The menu will automatically return to main menu after 30 of inactivity. page 16 of INSTRUCTION MANUAL - SES-KS-2422-E Rev. 3

17 SES-ASA ENGINEERING 2422 DIGITAL OUTPUTS CARD 16 CHANNELS 4.5. Board Configuration Switch Setting Table SW1 ACK influence on outputs ON OFF DP1 digital channels 1 8 not influenced by digital channels 1 8 in steady mode ACK command after ACK command DP2 digital channels 9 16 not influenced by digital channels 9 16 in steady ACK command mode after ACK command DP3 auxiliary channels 1 8 not influenced auxiliary channels 1 8 in steady by ACK command mode after ACK command DP4 not used must be on OFF position DP5 not used must be on OFF position DP6 not used must be on OFF position DP7 not used must be on OFF position DP8 ON: serial baud OFF: serial baud Note: This table is valid only if digital/auxiliary outputs are set as FLASHING (see 4.4.4) DP8 has to be left in OFF position. ON Its use is reserved for factory card test. SW2 Board address setting ( ) DP1.on Address with weight 1 DP2.on Address with weight 2 DP3.on Address with weight 4 DP4.on Address with weight 8 DP5.on Address with weight 16 DP6.on Address with weight 32 DP7.on Address with weight 64 DP8.on Address with weight 128 Note: it is not possible to configure more than one board with the same address Jumper Setting Table The card 2422 has the following jumpers: - JP1:...used to activate RESET signal - JP2:...used to power the serial bus 2480 JP1 Close: forced RESET - Open: non forced RESET JP2 Close: the board feeds the amplification circuit of the serial bus 2480 Open: the board does not feed the amplification circuit of the serial bus 2480 Factory setting must not be altered 2422 INSTRUCTION MANUAL - SES-KS-2422-E Rev. 3 page 17 of 24

18 2422 DIGITAL OUTPUTS CARD 16 CHANNELS SES-ASA ENGINEERING 4.6. Typical Connections page 18 of INSTRUCTION MANUAL - SES-KS-2422-E Rev. 3

19 SES-ASA ENGINEERING 2422 DIGITAL OUTPUTS CARD 16 CHANNELS 5. MAINTENANCE 5.1. General Module 2422, part of the F&G/ESD 2000 system should be installed following the specifications supplied, to ensure correct operation The entire system (sensors and electronics) should be tested at least once a year. Checking of module 2422 will include these steps: a) Check that cables and connections are integral and in good condition. b) Check that the system response is fully in accordance with the cause-effect table Storage a) The electronic modules should be stored in a dry room and at temperatures within the values indicated in section 2. b) If the modules are to be transported or stored for a long time, they should be contained in antistatic envelopes and packed with protective material INSTRUCTION MANUAL - SES-KS-2422-E Rev. 3 page 19 of 24

20 2422 DIGITAL OUTPUTS CARD 16 CHANNELS SES-ASA ENGINEERING 6. DIAGNOSTICS Board 2422, designed for management and control of 16 digital and 8 auxiliary output channels. For each digital channel the board gives indication of each channel status and allows enabling or disabling of the same when it is necessary (to avoid field actuation or when the channel is not used). For the auxiliary channels the enabling/disabling is possible only with the programming software. Board 2422 checks the logical section for correct feed voltage and operation. In case of a failure compromising microprocessor and logical section functionality, the Watchdog output is deactivated and the relevant front panel indication is activated 6.1. Board Diagnostics Board 2420 has two logically separated circuits: one is aimed to operating design function, the other verifies the circuitry so that it is always possible to detect and recognise any fault. The diagnostics is carried out on two levels: - power supply - operation of the microprocessor Diagnostics of Power Supplies and Microprocessor Board 2422, powered by one 24 V dc source named ISO is provided with a DC/DC converter dedicated to power supply of all of its sections. The following diagram shows the circuit used to diagnose the power supply and microprocessor functionality together with the watchdog circuit. page 20 of INSTRUCTION MANUAL - SES-KS-2422-E Rev. 3

21 SES-ASA ENGINEERING 2422 DIGITAL OUTPUTS CARD 16 CHANNELS 6.2. Troubleshooting This information is given as a guide to detect some of the most common operating problems. In case of failure, personnel authorised by SES ASA ENGINEERING SRL must carry out any repair. Any repair or tampering made by unauthorised personnel will invalidate the warranty. FAULT: Low feed voltage in I/O section. Possible Cause: Unsuitable, undersized or defective power supply. Too high resistance of supply line. Remedy: Give a power supply suitable to the system power requirements. Use power cables with suitable cross-area. FAULT: Activation indicated on the board but not made on the field. Possible Cause: The channel is in FAULT status (yellow LED is on). Output section fault. Remedy: Verify the output connections to the field. Replace the card. FAULT: Pushbuttons on front panel not operating. Possible Cause: The front panel buttons can be used only if previously enabled by the CPU Facility through relative command. Remedy: Enable the buttons through the Facility 2401 front panel buttons FAULT: Board not operating (Watchdog LED on front panel off). Possible Cause: Fault in electronics (microprocessor, internal power supply, etc.). Remedy: Check the protection fuses and/or replace the board. The indications and explanations above should be considered as a suggestion in case of failure or malfunction. Whenever the problem cannot be solved even after following the above instructions, or it is not listed, please contact SES ASA ENGINEERING SRL or their representative INSTRUCTION MANUAL - SES-KS-2422-E Rev. 3 page 21 of 24

22 2422 DIGITAL OUTPUTS CARD 16 CHANNELS SES-ASA ENGINEERING 7. CARD LAYOUT page 22 of INSTRUCTION MANUAL - SES-KS-2422-E Rev. 3

23 SES ASA ENGINEERING SRL Via Carolina Romani 8/ BRESSO (MI) ITALY Declare Under Proper Responsibility That PRODUCT : 2400 SERIES MODEL : 2422 Digital Outputs Card Is In Accordance With Following Directives: EMC 89/336CEE e 92/31/CEE EN CEI110-6 EN EN EN IEC IEC IEC801-2 e IEC In Legal Representation of Manufacturer SES ASA ENGINEERING SRL

24 SES-ASA ENGINEERING S.r.L. ENGINEERING & MANUFACTURING FIRE & GAS PROTECTION & AUTOMATION - Via C. Romani 8 / Bresso (MI) Italy - WEB: sesasa.it@gmb-group.com

Operating instructions. Speed monitor D / / 2014

Operating instructions. Speed monitor D / / 2014 Operating instructions Speed monitor D200 80005257 / 00 05 / 2014 Contents 1 Preliminary note...4 1.1 Symbols used...4 1.2 Warning signs used...4 2 Safety instructions...5 2.1 General...5 2.2 Target group...5

More information

Polymer Electric. Operating Instructions. Control Unit SG-EFS 1X4 ZK2/1 8k2. Version 3

Polymer Electric. Operating Instructions. Control Unit SG-EFS 1X4 ZK2/1 8k2. Version 3 Operating Instructions Control Unit SG-EFS 1X4 ZK2/1 8k2 Version 3 1003100 SG-EFS 104 ZK2/1 8k2 24 V=/~ 7500354 SG-EFS 134 ZK2/1 8k2 230 V~ Original instructions GmbH & Co. KG Polymer Electric Örlinger

More information

MR52 READER INTERFACE

MR52 READER INTERFACE IN IN2 IN3 IN4 INPUTS IN5 IN6 IN7 IN8 C www.mercury-security.com 2355 MIRA MAR AVE. LONG BEACH, CA 9085-755, (562)986-905 FAX (562) 986-9205 MR52 READER INTERFACE Installation and Specifications: This

More information

Operating instructions. Switching amplifier DN0210 DN / / 2015

Operating instructions. Switching amplifier DN0210 DN / / 2015 Operating instructions Switching amplifier DN0210 DN0220 UK 80011079 / 00 01 / 2015 Contents 1 Preliminary note...4 1.1 Symbols used...4 1.2 Warning signs used...4 2 Safety instructions...5 2.1 General...5

More information

D115 The Fast Optimal Servo Amplifier For Brush, Brushless, Voice Coil Servo Motors

D115 The Fast Optimal Servo Amplifier For Brush, Brushless, Voice Coil Servo Motors D115 The Fast Optimal Servo Amplifier For Brush, Brushless, Voice Coil Servo Motors Ron Boe 5/15/2014 This user guide details the servo drives capabilities and physical interfaces. Users will be able to

More information

Operating Instructions

Operating Instructions Innovative by tradition. Operating Instructions Control Unit SG-RSV 239 Version 1 1003986 SG-RSV 239/24 24 V= 1005372 SG-RSV 239/36 36 V= 1003271 SG-RSV 239 50-150 V= Mayser GmbH & Co. KG Örlinger Straße

More information

ICS Regent. Relay Output Modules. Low Power and High Power (T3446L and T3446H) PD-6017

ICS Regent. Relay Output Modules. Low Power and High Power (T3446L and T3446H) PD-6017 ICS Regent PD-6017 Relay Output Modules Low Power and High Power (T3446L and T3446H) Issue 1, March, 06 Relay output modules provide control of eight user output loads. Two types of relay output modules

More information

Polymer Electric. Operating Instructions. Control Unit SG-RST 153. Version 0.3

Polymer Electric. Operating Instructions. Control Unit SG-RST 153. Version 0.3 Operating Instructions Control Unit SGRST 153 Version 0.3 1004931 SGRST 153 Original instructions GmbH & Co. KG Örlinger Straße 1 3 89073 Ulm GERMANY Tel.: +49 731 20610 Fax: +49 731 2061222 EMail: info.ulm@mayser.com

More information

INSTALLATION MANUAL. LC 200 Electronic Overload Guard. Software versione PW0501 R 0.3

INSTALLATION MANUAL. LC 200 Electronic Overload Guard. Software versione PW0501 R 0.3 INSTALLATION MANUAL LC 200 Electronic Overload Guard Software versione PW0501 R 0.3 CONTENTS MAIN FEATURES LC 200 TECHNICAL FEATURES Page 2 SYMBOLS Page 3 WARNINGS Page 3 IDENTIFICATION DATA PLATE Page

More information

Operating instructions Evaluation system for flow sensors VS / / 2013

Operating instructions Evaluation system for flow sensors VS / / 2013 Operating instructions Evaluation system for flow sensors VS3000 7097 / 0 07 / 203 Contents Preliminary note...2 2 Safety instructions...3 3 Function and features... Mounting.... Mounting of the sensors...

More information

SIU-218 and SIU-2218

SIU-218 and SIU-2218 SIU-218 and SIU-2218 Serial Interface Unit THIS MANUAL CONTAINS TECHNICAL INFORMATION FOR THE SIU-218 AND SIU-2218 SERIES SERIAL INTERFACE UNIT REVISION: OCTOBER 2013 pn 888-0218-001 THE SIU-218 AND SIU-2218

More information

Channel Switch CS. General Operating, Maintenance and Installation Manual

Channel Switch CS. General Operating, Maintenance and Installation Manual Channel Switch CS General Operating, Maintenance and Installation Manual D-91056 Erlangen Phone: +49 9131 7677 47 Fax: +49 9131 7677 74 Internet: http://www.ipcomm.de Email: info@ipcomm.de Edition September

More information

Control unit SG-EFS 104/2W. EN Operating instructions. Innovative by tradition. Version SG-EFS 104/2W 24 V=/~

Control unit SG-EFS 104/2W. EN Operating instructions. Innovative by tradition. Version SG-EFS 104/2W 24 V=/~ Innovative by tradition. Control unit SG-EFS 104/2W EN Operating instructions Version 0.9 1005196 SG-EFS 104/2W 24 V=/~ Original instructions Mayser GmbH & Co. KG Örlinger Straße 1 3 89073 Ulm GERMANY

More information

LCI User Manual mantracourt.com

LCI User Manual mantracourt.com LCI User Manual mantracourt.com LCI Load Cell Junction Box with Fault Monitor Contents Chapter 1 Introduction to the LCI... 2 Chapter 2 Installing the LCI... 3 Chapter 3 Setting up the LCI... 4 Sequence

More information

AS-i Safety Relay Output Module with Diagnostic Slave

AS-i Safety Relay Output Module with Diagnostic Slave AS-i Safety Relay Output Module with Diagnostic Slave User Manual...supports the requirements for AS-i Safety up to SIL3 Revision date: 2016-03-9 Subject to modifications without notice. Generally, this

More information

Sigma Si. Extinguishant Status Unit (K , K , K , K , K , K , K , K )

Sigma Si. Extinguishant Status Unit (K , K , K , K , K , K , K , K ) Sigma Si Extinguishant Status Unit (K91100055, K91100056, K91110055, K91110056, K91111055, K91111056, K91111355, K91111356) Operation and Maintenance Manual Man1089 Issue 07 June 2013 Index Section Page

More information

Model HM-535 Power Supply Installation and Service Instructions

Model HM-535 Power Supply Installation and Service Instructions Model HM-535 Power Supply Installation and Service Instructions 430-535 0104 2004 Heritage MedCall, Inc SENTRY INSTALLATION & SERVICE INSTRUCTIONS POWER SUPPLY UNIT Model HM-535 IMPORTANT SAFETY INSTRUCTIONS

More information

AI-917-A0. Analogue Input Module (4x 0-20 ma)

AI-917-A0. Analogue Input Module (4x 0-20 ma) General Specifications GS48D17A00-00E-N AI-917-A0 Analogue Input Module (4x 0-20 ma) GENERAL Figure 1 This module has four analogue inputs and four logic pulse outputs. AI-917-A0 Analogue Input Module

More information

Technical data. Safety notes. Product features

Technical data. Safety notes. Product features Technical data sheet BKN230-MOD 11-00002.F Communication and power supply unit for motorised fire dampers Communication via RTU (RS-48) AC 230 V supply via Euro plug Power is supplied to the actuators

More information

OVEN INDUSTRIES, INC.

OVEN INDUSTRIES, INC. OVEN INDUSTRIES, INC. OPERATING MANUAL MODEL 5C7-195 THERMOELECTRIC MODULE TEMPERATURE CONTROLLER TABLE OF CONTENTS Page Features...1 Description...2 Block Diagram...2 Mechanical Package Drawing...3 RS232

More information

MC 11 EB-2 Power supply cabinet with external bus, AC version

MC 11 EB-2 Power supply cabinet with external bus, AC version MC 11 EB-2 Power supply cabinet with external bus, AC version USER/MAINTENANCE MANUAL 1 SLOT 0 SLOT 1 SLOT 2 SLOT 3 SLOT 4 SLOT 5 SLOT 6 SLOT 7 SLOT 8 SLOT 9 SLOT 10 SLOT 11 EB-2 (a) MC11 (b) (c) Figures

More information

LVX Control Unit. Features:

LVX Control Unit. Features: Date 2013-02-28 Control Unit Features: Most parameters can be defined as required for your interfaces. You decide which information is output and how. Fast cycle times, just a few µs/beam. Maximum beam-count

More information

Original operating instructions Safety relay with relay outputs G1501S / / 2016

Original operating instructions Safety relay with relay outputs G1501S / / 2016 Original operating instructions Safety relay with relay outputs G50S UK 8023637 / 00 02 / 206 Contents Preliminary note...4. Symbols used...4 2 Safety instructions...5 3 Items supplied...6 4 Functions

More information

RXTH DUAL ROOM SENSOR / SWITCH

RXTH DUAL ROOM SENSOR / SWITCH DUAL ROOM SENSOR / SWITCH FOR TEMPERATURE AND RELATIVE HUMIDITY Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE

More information

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016 Operating instructions AS-i SmartLine module AC3200 AC3201 80237876/00 06/2016 Contents 1 Preliminary note...3 1.1 Symbols used...3 1.2 Warnings used...3 2 Safety instructions...3 2.1 General...3 2.2 Target

More information

ATS-16 HV USER MANUAL. Automatic Transfer Switch 16A / 230Vac V090318

ATS-16 HV USER MANUAL. Automatic Transfer Switch 16A / 230Vac V090318 ATS-16 HV Automatic Transfer Switch 16A / 230Vac USER MANUAL V090318 SAFETY Intended use The ATS-16 HV device serves as a power source selector to provide improved power supply for connected loads. ATS-16

More information

Operating Manual UMB ISO Converter ISOCON Order Number: 8160.UISO

Operating Manual UMB ISO Converter ISOCON Order Number: 8160.UISO Order Number: 8160.UISO Status: V3; 17.09.2010c G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany 1 TABLE OF CONTENTS PLEASE READ BEFORE USE... 3 DESCRIPTION... 5 UMB ISO CONVERTER ISOCON... 6 CONFIGURATION...

More information

RST ROOM TEMPERATURE TRANSMITTER. Mounting and operating instructions

RST ROOM TEMPERATURE TRANSMITTER. Mounting and operating instructions Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE 4 TECHNICAL DATA 4 STANDARDS 4 OPERATIONAL DIAGRAM 5 WIRING AND

More information

AV24-MFT AV24-MFT2 AV24-MFT2-C105. Power consumption In operation For wire sizing N 1700 N Control Control signal Y Operating range

AV24-MFT AV24-MFT2 AV24-MFT2-C105. Power consumption In operation For wire sizing N 1700 N Control Control signal Y Operating range echnical data sheet AV4-MF()(-C105) Multi-functional linear actuators for -way and 3-way globe valves Actuating force 500 N Nominal voltage AC/DC 4 V Control: modulating DC 0 10 V Position feedback DC

More information

LCI Load Cell Junction Box with Fault Monitor

LCI Load Cell Junction Box with Fault Monitor LCI Load Cell Junction Box with Fault Monitor User Manual www.mantracourt.co.uk The LCI Load Cell Failure Alarm Manual Chapter 1 Introduction to the LCI...2 Chapter 2 Installing the LCI...3 Figure 2.1

More information

NMID. Remote control. SAPIM I/O number. SAPIM I/O number NBRN (RS485) ZM100. Relay, 24 VDC - + UO07 UI11 UI10 UI09 UI08 UI07 UI06 UI05 UI04 UI03 UI02

NMID. Remote control. SAPIM I/O number. SAPIM I/O number NBRN (RS485) ZM100. Relay, 24 VDC - + UO07 UI11 UI10 UI09 UI08 UI07 UI06 UI05 UI04 UI03 UI02 1/8 NRK16/A, NRK16-B/A, (NRK16-T /A, NRK14-T /A, NRK16-WEB/A) Control and interlock devices with pre-programmed system-specific application modules The controllers may be used as stand-alone control and

More information

Operating instructions AC010S Compact AS-i E-STOP safety module

Operating instructions AC010S Compact AS-i E-STOP safety module Operating instructions AC010S Compact AS-i E-STOP safety module Sachnr. 7390636_/00 05/2007 Contents Safety instructions............................. 3 Installation / Setup............................

More information

Sigma-XT-ECU-LCS Extinguishant Control Unit Local Control Station Operation and Maintenance Manual

Sigma-XT-ECU-LCS Extinguishant Control Unit Local Control Station Operation and Maintenance Manual SigmaXTECULCS Extinguishant Control Unit Local Control Station Operation and Maintenance Manual SigmaXTECULCS Issue 1 October 2011 Index Section Page 1 Introduction... 3 2 Safety and mounting... 3 2.1

More information

Product Information. Release 3 4 SIMATIC S7-300

Product Information. Release 3 4 SIMATIC S7-300 Product Information SIMATIC S7-300 Relay Output Module SM 322; DO 8 x REL AC230V/5A X 2 Release 3 4 New Relay Output Module Available The S7-300 Relay Output Module SM 322; DO 8 REL AC230V/5A has been

More information

Manual Control Unit GFC 32

Manual Control Unit GFC 32 Manual Control Unit 1400004_EN/05.2017 Index 1. Main features 3 2. Technical features 3 3. Installation guidelines 4 4. Preliminary checks 5 5. Electrical connections 5 6. Settings 6 7. Remote control

More information

MCR 808LX RELAY MANAGEMENT MODULE

MCR 808LX RELAY MANAGEMENT MODULE RELAY MANAGEMENT MODULE This installation manual has been written by the manufacturer and it is considered integrating part of this product. The information included are intended for the expert technicians

More information

M82xxD Fiber Optic RS-232 MicroModem Technical Manual

M82xxD Fiber Optic RS-232 MicroModem Technical Manual M82xxD Fiber Optic RS-232 MicroModem Technical Manual Revision C August 2016 VERSITRON, Inc. 83 Albe Drive / Suite C Newark, DE 19702 www.versitron.com Safeguarding Communications Since 1958 PROPRIETARY

More information

RXTP ROOM TEMPERATURE

RXTP ROOM TEMPERATURE ROOM TEMPERATURE CONTROLLER WITH PI CONTROL Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE 4 TECHNICAL DATA 4

More information

DXTH DUCT SENSOR / SWITCH FOR TEMPERATURE AND HUMIDITY. Mounting and operating instructions

DXTH DUCT SENSOR / SWITCH FOR TEMPERATURE AND HUMIDITY. Mounting and operating instructions DUAL DUCT SENSOR / SWITCH FOR TEMPERATURE AND HUMIDITY Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE 4 TECHNICAL

More information

AS-i Safety Relay Output Module with Diagnostic Slave

AS-i Safety Relay Output Module with Diagnostic Slave AS-i Safety Relay Output Module with Diagnostic Slave User Manual Revision date: 2013-01-30...supports the requirements for AS-i Safety up to SIL3 Subject to modifications without notice. Generally, this

More information

Iso DIN. User Manual. 1 channel Earth Fault Monitoring

Iso DIN. User Manual. 1 channel Earth Fault Monitoring Page 1 of 5 2017 03 20 User Manual Iso DIN Iso DIN User Manual 1 channel Earth Fault Monitoring Megacon AB Ranhammarsvägen 20 S 168 67 Bromma Sweden Tel: 08 402 42 50 sales@megacon.se www.megacon.se eee

More information

Original operating instructions Safety relay with relay outputs with and without delay G1502S / / 2016

Original operating instructions Safety relay with relay outputs with and without delay G1502S / / 2016 Original operating instructions Safety relay with relay outputs with and without delay UK G50S 803638 / 00 0 / 06 Contents Preliminary note...4. Symbols used...4 Safety instructions...5 3 Items supplied...6

More information

Control unit SG-EFS 104/4L. EN Operating instructions. Innovative by tradition. Version SG-EFS 104/4L AC/DC 24 V

Control unit SG-EFS 104/4L. EN Operating instructions. Innovative by tradition. Version SG-EFS 104/4L AC/DC 24 V Innovative by tradition. Control unit SG-EFS 104/4L EN Operating instructions Version 2 1004128 SG-EFS 104/4L AC/DC 24 V Original instructions Mayser GmbH & Co. KG Örlinger Straße 1 3 89073 Ulm GERMANY

More information

CRM Control Panel and Weather Detection System CRM3 for DC actuators (part # 40821J) CRM4 for AC actuators (part # 40822K)

CRM Control Panel and Weather Detection System CRM3 for DC actuators (part # 40821J) CRM4 for AC actuators (part # 40822K) CRM Control Panel and Weather Detection System CRM3 for DC actuators (part # 40821J) CRM4 for AC actuators (part # 40822K) CRM Applications CRM includes a control relay box and a power supply; additional

More information

Sigma Si Weatherproof Extinguishant Status Unit (W911000W8, W911100W8, W911110W8, W911113W8)

Sigma Si Weatherproof Extinguishant Status Unit (W911000W8, W911100W8, W911110W8, W911113W8) Sigma Si Weatherproof Extinguishant Status Unit (W911000W8, W911100W8, W911110W8, W911113W8) Operation and Maintenance Manual Man1097 Issue 02 October 2009 Index Page 1. Introduction... 3 2. Safety and

More information

GT- IRDM-9603 Product description Rev. 2 17/06/2014

GT- IRDM-9603 Product description Rev. 2 17/06/2014 GT- IRDM-9603 Product description Rev. 2 17/06/2014 1 1. Overview The GT- IRDM- 9603 is a complete Satellite Terminal solution for Satellite applications. Based on IRIDIUM 9603 module. 2. Hardware Interface

More information

RТTH DUAL ROOM SWITCH

RТTH DUAL ROOM SWITCH DUAL ROOM SWITCH FOR TEMPERATURE AND RELATIVE HUMIDITY Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS PRODUCT DESCRIPTION ARTICLE CODES INTENDED AREA OF USE TECHNICAL DATA

More information

IO-INTERFACE. Procon. INSTALLATION MANUAL Version 1.01 MITSUBISHI ELECTRIC FOR INSTALLERS

IO-INTERFACE. Procon. INSTALLATION MANUAL Version 1.01 MITSUBISHI ELECTRIC FOR INSTALLERS Procon IO-INTERFACE FOR INSTALLERS INSTALLATION MANUAL Version 1.01 For safe and correct use, please read this installation manual thoroughly before installing the PROCON IO-INTERFACE. MITSUBISHI ELECTRIC

More information

Quick Start Installation Guide

Quick Start Installation Guide apc/l Quick Start Installation Guide Version A2 Document Part Number UM-201 May 2010 OVERVIEW The apc/l is an intelligent access control and alarm monitoring control panel which serves as a basic building

More information

AS-i Safety Relay Output Module with Diagnostic Slave, 1 EDM, 1 x 2 channel Safe Input

AS-i Safety Relay Output Module with Diagnostic Slave, 1 EDM, 1 x 2 channel Safe Input ext. in ext. in AS-i Safety Relay Output Module with Safety + standard I/O in one module Safety relay output with galvanically isolated contact sets, approved up to 230 V Additionally 1 EDM input, 1 x

More information

LM24A-MOD. Cable 1 m, 6 x 0.75 mm 2 RJ12 socket

LM24A-MOD. Cable 1 m, 6 x 0.75 mm 2 RJ12 socket echnical data sheet Damper actuator for Modbus for adjusting air dampers in ventilation and air conditioning systems in buildings orque 5 Nm Nominal voltage AC/DC 4V Communication via Modbus RU (RS-485)

More information

OPERATION MANUAL SMARTLAB USB 8 CHANNELS RELAY OUTPUT 8 CHANNELS PHOTO ISOLATOR INPUT BOARD

OPERATION MANUAL SMARTLAB USB 8 CHANNELS RELAY OUTPUT 8 CHANNELS PHOTO ISOLATOR INPUT BOARD SMARTLAB USB 8 CHANNELS RELAY OUTPUT 8 CHANNELS PHOTO ISOLATOR INPUT BOARD OPERATION MANUAL CHAPTERS 1. Introduction.. 1 2. Hardware Configuration..... 5 3. Diagnostic under Windows/XP 12 4. Programming

More information

180 Series Keypad. Handbook. Revision 2.1

180 Series Keypad. Handbook. Revision 2.1 180 Series Keypad Handbook Revision 2.1 Revision History Revision 1.0 Initial release Revision 2.0 Major update with addition of 180-40 Added 180-40 to document and various headings Note regarding unique

More information

E1 Plus Electronic Overload Relay

E1 Plus Electronic Overload Relay ROCKWELL AUTOMATION PROCUREMENT SPECIFICATION PROCUREMENT SPECIFICATION E1 Plus NOTICE: The specification guidelines in this document are intended to aid in the specification of products. Specific installations

More information

AS-i Safety Relay Output Module with Diagnostic Slave and 1 EDM Input

AS-i Safety Relay Output Module with Diagnostic Slave and 1 EDM Input Safety + standard I/O in one module Safety relay output with galvanically isolated contact sets, approved up to 230 V IEC 61508 SIL 3, EN ISO 13849-1/PLe Kat 4, EN 62061 SIL 3 Protection category IP20

More information

ICS Regent. Multiplexed I/O Modules PD-6035 (T3491)

ICS Regent. Multiplexed I/O Modules PD-6035 (T3491) ICS Regent Multiplexed I/O Modules (T3491) Issue 1, March, 06 Multiplexed I/O modules provide two RS-422 serial port interfaces between the Regent system and ICS s remote multiplexed I/O Unit (MIU) equipment,

More information

Model NM512. TS1 Conflict Monitor Standard 12 Channel Unit. Naztec Operations Manual. For. Published by

Model NM512. TS1 Conflict Monitor Standard 12 Channel Unit. Naztec Operations Manual. For. Published by Naztec Operations Manual For Model NM512 TS1 Conflict Monitor Standard 12 Channel Unit Published by Naztec, Inc. 820 Park Two Dr. Sugar Land, Texas 77478 Phone: (281) 2407233 Fax: (281) 240-7238 Copyright

More information

Product and functional description

Product and functional description Product and functional description Connection example The universal dimmer main module N 528/31 is an installation device for DIN-rail mounting, with N-system dimensions. It is designed for lighting control,

More information

AirTest Model CN9000 Series Sensor Controller

AirTest Model CN9000 Series Sensor Controller AirTest Model CN9000 Series Sensor Controller AirTest Model CN9000 Series Sensor Controller THEORY OF OPERATION A basic CN9000 configuration consists of Input/Process/Display combination modules, a 3 relay

More information

MAINTENANCE MANUAL. EDACS REDUNDANT POWER SUPPLY SYSTEM 350A1441P1 and P2 POWER MODULE CHASSIS 350A1441P3, P4, AND P5 POWER MODULES TABLE OF CONTENTS

MAINTENANCE MANUAL. EDACS REDUNDANT POWER SUPPLY SYSTEM 350A1441P1 and P2 POWER MODULE CHASSIS 350A1441P3, P4, AND P5 POWER MODULES TABLE OF CONTENTS MAINTENANCE MANUAL EDACS REDUNDANT POWER SUPPLY SYSTEM 350A1441P1 and P2 POWER MODULE CHASSIS 350A1441P3, P4, AND P5 POWER MODULES TABLE OF CONTENTS SPECIFICATIONS*... 2 INTRODUCTION... 3 DESCRIPTION...

More information

NSI DIGITAL DIMMING SYSTEM DDS 5300 / 5600 DIMMER PACK

NSI DIGITAL DIMMING SYSTEM DDS 5300 / 5600 DIMMER PACK INTRODUCTION NSI DIGITAL DIMMING SYSTEM INSTALLATION AND OPERATION GUIDE The NSI DDS 5300 and DDS 5600 dimmers represent a key part of a state of the art, integrated lighting control system. These dimmers

More information

ACOPOSinverter P74. User's Manual. Version: 2.20 (August 2016) Model no.: Original instruction

ACOPOSinverter P74. User's Manual. Version: 2.20 (August 2016) Model no.: Original instruction ACOPOSinverter P74 User's Manual Version: 2.20 (August 2016) Model no.: MAACPIP74-ENG Original instruction All information contained in this manual is current as of its creation/publication. We reserve

More information

PCLD-8751 PCLD User Manual

PCLD-8751 PCLD User Manual PCLD-8751 48-Channel Opto-isolated D/I Board PCLD-8761 24-Channel Opto-isolated D/I and 24-Channel Relay Board User Manual Copyright The documentation and the software included with this product are copyrighted

More information

Original operating instructions Fail-safe inductive sensor GF711S / / 2013

Original operating instructions Fail-safe inductive sensor GF711S / / 2013 Original operating instructions Fail-safe inductive sensor GF7S 8528 / 5 / 23 Contents Preliminary note...3. Explanation of symbols...3 2 Safety instructions...4 2. Safety-related requirements regarding

More information

HydroLynx Systems, Inc. Model 50386D Decoder Instruction Manual

HydroLynx Systems, Inc. Model 50386D Decoder Instruction Manual HydroLynx Systems, Inc. Model 50386D Decoder Instruction Manual Document No: WD102681-1 Document Revision Date: April, 2011 HydroLynx Systems, Inc. Model 50386D Decoder Receiving and Unpacking Carefully

More information

Installation & Operation Guide

Installation & Operation Guide Installation & Operation Guide (Shown with optional Override Board Cover) KMD-5831 Programmable Loop Controller PLC-28 Direct Digital Controller 902-019-04B 1 Introduction This section provides a brief

More information

EPS Power Supply

EPS Power Supply EPS - 600 Power Supply Installation and Operation Manual Version 1.0 *This instrument is intended for laboratory use only Index A. Important Notice ----------------------------------------------------------------

More information

Operating and installation instructions Differential pressure monitor

Operating and installation instructions Differential pressure monitor Operating and installation instructions Differential pressure monitor RM-DPC Micro SensorLine Table of contents 1 Safety instructions...3 2 Equipment specification...3 3 Assembly...4 4 Step-by-step installation...4

More information

OPERATOR MANUAL OSD157 FIBER OPTIC RS422/RS232 MODEM/MULTIPLEXER

OPERATOR MANUAL OSD157 FIBER OPTIC RS422/RS232 MODEM/MULTIPLEXER / OPERATOR MANUAL OSD157 FIBER OPTIC RS422/RS232 MODEM/MULTIPLEXER PAGE 2 OF 17 INDEX 1 1. TECHNICAL SUMMARY... 4 1.1 BRIEF DESCRIPTION... 4 1.1.1 OVERVIEW... 4 1.1.2 APPLICATIONS... 4 1.1.3 FEATURES AND

More information

TABLE OF CONTENTS INTRODUCTION. 3. Analog Input Analog Output Digital Input Digital Output OPERATIONAL DESCRIPITON.. 7 PROGRAMMING AND INITIAL SETUP.

TABLE OF CONTENTS INTRODUCTION. 3. Analog Input Analog Output Digital Input Digital Output OPERATIONAL DESCRIPITON.. 7 PROGRAMMING AND INITIAL SETUP. DIVERSIFIED HEAT TRANSFER SERIES 700 STEAM GENERATOR CONTROLLER INSTRUCTION MANUAL VISIT OUR WEBSITE AT SIGMACONTROLS.COM SERIES 700 DHT STEAM GENERATOR MANUAL 042514 2 TABLE OF CONTENTS INTRODUCTION.

More information

Strain Gauge Converter

Strain Gauge Converter EN Z-SG General Description Module Z-SG is a strain gauge signal converter. Measurements taken using the 6-wires or 4-wires technique are available through Modbus-RTU serial protocol or the analog output.

More information

GRASSO SYSTEM CONTROL

GRASSO SYSTEM CONTROL Control device for Packages and Chillers with screw compressors Product information 09.2002/ 2 638630_pi gsc gbr.doc Copyright GmbH Refrigeration Technology The contents of this documentation and the enclosed

More information

RTT2 ROOM TEMPERATURE SWITCH. Mounting and operating instructions

RTT2 ROOM TEMPERATURE SWITCH. Mounting and operating instructions Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS PRODUCT DESCRIPTION ARTICLE CODES INTENDED AREA OF USE TECHNICAL DATA STANDARDS OPERATIONAL DIAGRAMS WIRING AND CONNECTIONS

More information

SEQUENCER FOR DEDUSTING PLANTS

SEQUENCER FOR DEDUSTING PLANTS BB SEQUENCER FOR DEDUSTING PLANTS PLEASE READ THE WHOLE USER MANUAL CAREFULLY BEFORE INSTALLING THE EQUIPMENT 1. ENTER DATAS IN SET MODE 1. Press key C to have access to the function menu F01 F13. 2. Press

More information

Series 8000 RF Signal Switch Solution

Series 8000 RF Signal Switch Solution RF Signal Switch Solution Operation Manual Operation Manual, Part Number 07508000-006, Rev. A, May 17, 2013 All technical data and specifications in this publication are subject to change without prior

More information

I/O SIGNAL CONDITIONER

I/O SIGNAL CONDITIONER Technical Data Sheet No. TD9809M Rev. F Date of Issue: December 9, 2009 OPERATING MANUAL I/O SIGNAL CONDITIONER CAUTION: THIS PRODUCT DOES NOT PROVIDE GALVANIC ISOLATION. DO NOT ATTEMPT USE OF THIS PRODUCT

More information

Users Manual. TABLE OF CONTENTS 1 WORKING PRINCIPLE Operating limits Applications... 2

Users Manual. TABLE OF CONTENTS 1 WORKING PRINCIPLE Operating limits Applications... 2 instrumentación para fluidos Digital frequency divider DFD-2 E Users Manual TABLE OF CONTENTS 1 WORKING PRINCIPLE... 2 1.1 Operating limits... 2 1.2 Applications... 2 2 INSTALLATION... 2 2.1 Mains connection...

More information

Manual Simatek Control Unit GFC 32

Manual Simatek Control Unit GFC 32 Manual Simatek Control Unit GFC 32 Original instructions 1400004_GB Ver. 2014.01.09 Index 1. Main features 3 2. Technical features 3 3. Installation guidelines 4 4. Preliminary checks 5 5. Electrical connections

More information

Dolphin DXE410 Expansion Chassis

Dolphin DXE410 Expansion Chassis Dolphin DXE410 Expansion Chassis User Guide Revision Information: Revision 2.0 Dolphin Interconnect Solutions, 225 Cedar Hill Street, Marlborough, MA 01752 www.dolphinics.com September 2008 Dolphin Interconnect

More information

Emerson Network Power provides customers with technical support. Users may contact the nearest Emerson local sales office or service center.

Emerson Network Power provides customers with technical support. Users may contact the nearest Emerson local sales office or service center. Liebert PSA iton User Manual Version: V2.8 Revision date: November 14, 2005 Emerson Network Power provides customers with technical support. Users may contact the nearest Emerson local sales office or

More information

ICTD-100CP / ICTD-101CP ICTD-102CP / ICTD-103CP

ICTD-100CP / ICTD-101CP ICTD-102CP / ICTD-103CP PATENT PENDING ICTD-100CP / ICTD-101CP ICTD-102CP / ICTD-103CP Capacitor Trip Devices with Contact Protect Technology TM Operation Manual and Data sheet 2015 Intermountain Electronics, Inc. Important Notice

More information

32-Channel Analogue Input Module Differential Input

32-Channel Analogue Input Module Differential Input MAI32*AD 32-Channel Analogue Input Module Differential Input (MAI32*AD) Issue 4 October 2005 INTRODUCTION PURPOSE The Analogue Input Module provides up to 32, low voltage or current analogue input signals.

More information

MAXIMA+ Series Rotary Level Indicator

MAXIMA+ Series Rotary Level Indicator MAXIMA+ Series Rotary Level Indicator BinMaster: Division of Garner Industries 7201 N. 98th St., Lincoln, NE 68507 402-434-9102 email: info@binmaster.com www.binmaster.com OPERATING INSTRUCTIONS PLEASE

More information

DS BAS /99 UNC 596 BUILDING AUTOMATION SYSTEM UNIVERSAL NETWORK CONTROLLER FEATURES

DS BAS /99 UNC 596 BUILDING AUTOMATION SYSTEM UNIVERSAL NETWORK CONTROLLER FEATURES DS 13.321 BAS 2800+ 06/99 UNC 596 BUILDING AUTOMATION SYSTEM UNIVERSAL NETWORK CONTROLLER Specification no. 579-1-904 The Universal Network Controller (UNC 596) is fully intelligent and incorporates its

More information

The accessories described in this manual are of the highest quality, carefully designed and built in order to ensure excellent performance.

The accessories described in this manual are of the highest quality, carefully designed and built in order to ensure excellent performance. INTRODUCTION Thank you for choosing our product. The accessories described in this manual are of the highest quality, carefully designed and built in order to ensure excellent performance. This manual

More information

16-Channel Digital Output Module 120Vac/dc

16-Channel Digital Output Module 120Vac/dc Triguard SC300E MDO16FNS 16-Channel Digital Output Module 120Vac/dc (MDO16FNS) Issue 4 October 2005 INTRODUCTION PURPOSE The 120Vac/dc Digital Output Module MDO16FNS provides the output control interface

More information

CA-A480-A Elevator Controller. Reference & Installation Manual

CA-A480-A Elevator Controller. Reference & Installation Manual CA-A480-A Elevator Controller Reference & Installation Manual TABLE OF CONTENTS INTRODUCTION.................................................................. 4 Introduction.............................................................................................

More information

DORMA. Installation Manual Extension kit I/O module in the B6L 4P

DORMA. Installation Manual Extension kit I/O module in the B6L 4P DORMA Installation Manual Extension kit I/O module in the B6L 4P Contents Contents 1 General information......................... 3 1.1 Preface................................. 3 1.2 Correct use.............................

More information

Description of the amplifier s functions.

Description of the amplifier s functions. USERS MANUAL User manual purpose This user manual is dedicated to the use of the bass amplifier GR 700+. The manual includes the following information: General information (technical data and packaging);

More information

Sigma XT Ancillary Board (K588)

Sigma XT Ancillary Board (K588) Sigma XT Ancillary Board (K588) Operation and Maintenance Manual Man-1095 Issue 04 October 2009 Index Section Page 1. Introduction... 3 2. Safety and mounting... 3 3. Technical specification... 4 4. Connecting

More information

Contents. HP E1586A Rack Mount Terminal Panel User s Manual

Contents. HP E1586A Rack Mount Terminal Panel User s Manual Contents HP E1586A Rack Mount Terminal Panel User s Manual Description... 5 Connecting to VXIbus Instruments... 5 Interconnect Cables... 5 Terminal Block Connections... 6 Using the Terminal Panel for Reference

More information

Answers to Chapter 2 Review Questions. 2. To convert controller signals into external signals that are used to control the machine or process

Answers to Chapter 2 Review Questions. 2. To convert controller signals into external signals that are used to control the machine or process Answers to Chapter 2 Review Questions 1. To accept signals from the machine or process devices and to convert them into signals that can be used by the controller 2. To convert controller signals into

More information

Operating instructions Memory plug E /02 11/2011

Operating instructions Memory plug E /02 11/2011 Operating instructions Memory plug E30398 UK 704930/02 11/2011 Contents 1 Preliminary note...3 1.1 Symbols used...3 1.2 Terms used...3 2 Safety instructions...4 3 Factory setting...4 4 Functions and features...5

More information

KNX is a European Standard Protocol used for household and industrial Buliding Management System (BMS).

KNX is a European Standard Protocol used for household and industrial Buliding Management System (BMS). PRODUCT NEWS Products News: New HC-A16KNX PAGE 1 / 8 Summary 1. This advanced product news introduces the new product HC-A16KNX. 2. The details are indicated in the description. Description 1. Applicable

More information

Original operating instructions. Fail-safe SmartPLC with Profinet slave interface AC402S /00 06/2016

Original operating instructions. Fail-safe SmartPLC with Profinet slave interface AC402S /00 06/2016 Original operating instructions Fail-safe SmartPLC with Profinet slave interface AC402S UK 80237419/00 06/2016 Contents 1 Preliminary note...4 1.1 Notes on this document...4 1.2 Symbols used...4 2 Safety

More information

2-Way Wireless I/O Expander Installation Guide

2-Way Wireless I/O Expander Installation Guide 2-Way Wireless I/O Expander Installation Guide For more detailed information please refer to the iconnect Installer Manual provided on our website: www.electronics-line.com Table of Contents 1. Introduction...

More information

Installation and commissioning guide SmartLink PSD Power Supply Module (DC)

Installation and commissioning guide SmartLink PSD Power Supply Module (DC) Installation and commissioning guide SmartLink PSD Power Supply Module (DC) Rev. 1 September 2012 Part No. 4417551 Enraf B.V. P.O. Box 812 2600 AV Delft Netherlands Tel. : +31 15 2701 100 Fax : +31 15

More information

SDM-6RO. Expansion Module 6 relay outputs. Manufactured for

SDM-6RO. Expansion Module 6 relay outputs. Manufactured for Version 1.0 5.02.2014 Manufactured for Thank you for choosing our product. This manual will help you with proper support and proper operation of the device. The information contained in this manual have

More information

MAXIMA + Series ROTARY LEVEL CONTROL

MAXIMA + Series ROTARY LEVEL CONTROL Price $5.00 MAXIMA + Series ROTARY LEVEL CONTROL OPERATING INSTRUCTIONS PLEASE READ CAREFULLY Division of Garner Industries 7201 North 98th Street Lincoln, NE 68507-9741 (402) 434-9102 925-0268 Rev. A

More information

Operation Manual. Concorde 600 Power Supply. *This instrument is intended for laboratory use only.

Operation Manual. Concorde 600 Power Supply. *This instrument is intended for laboratory use only. Concorde 600 Power Supply Operation Manual Cat.no. R10-1001011 *This instrument is intended for laboratory use only http://www.recenttec.com E-mail : support@recenttec.com Version 1.1 Packing List x 1

More information