Privacy Wall - Power & Data Box (Field Installed) Modular & Hardwire Versions

Size: px
Start display at page:

Download "Privacy Wall - Power & Data Box (Field Installed) Modular & Hardwire Versions"

Transcription

1 Privacy Wall - Power & Data Box (Field Installed) Modular & Hardwire Versions If you have a problem, question, or request, call your local dealer, or Steelcase Line 1 at 888.STEELCASE ( ) for immediate action by people who want to help you. (Outside the U.S.A., Canada, Mexico, Puerto Rico, and the U.S. Virgin Islands, call: ) Or visit our website: Steelcase Inc. Grand Rapids, MI U.S.A. Printed in U.S.A. NOTE: Unused modular electrical connector openings are not required to be capped. Page 1 of 15

2 Tools Table of Contents ELECTRIC SHEARS 2" WIDE MASKING TAPE Topic Determining the Opening 3 Page Removing the Skin 4-5 Removing the Acoustic Core Material 6 Installing Power 7 Installing the Modular Version 8 Mounting a Base Power Block 9 Chicago & New York City Hardwire Box and Bracket Assembly Wiring Schematics 15 RAYBO FLOOR COVERING -WET/DRY- VAC Page 2 of 15

3 1b 6-3/8" 2 Determining the Opening 1. Find the center of the panel (1a) and mark the width of the opening. Determine the height you want the opening from the bottom of the panel and mark the height of the opening (1b). Use a straight edge to connect your marks (1c). 2. The size of the opening. 28-1/2" (DESK HT.) 16-1/8" (ADA HT.) BOTTOM OF SKIN 4" C L 8" 1a C L OF PANEL 1c Page 3 of 15

4 1 2b Removing the Skin 1. Masking tape is applied to protect surrounding surface material. NOTE: Tape should not be applied to wall for more than 1 hour. 2. For fabric and/or vinyl panel, cut the perimeter out with a utility knife (2a, b & c). TIP: Place cardboard around opening to protect outside surface from getting dirt or damage while using tools. 2a 2c Page 4 of 15

5 4 Removing the Skin (cont.) 3. Drill all four (4) holes slightly offset from the corners to help provide for a sharp 90 corner. 4. Use electrical shears on all four (4) sides to remove panel covering. 3a 5. Use a utility knife on all four (4) sides to cut through the acoustical core and remove. 5 3b CAUTION: Make sure utility knife blade is not to long, to damage opposite face. Page 5 of 15

6 1 Removing the Acoustic Core Material 1. File down the edges. 2. Remove acoustical core material 3" left & right from the cut side ONLY. If installing a Chicago & New York City hardwire box, you will need to remove 5" from the bottom edge of the cut side opening also. 3" CAUTION: It is very important to remove this material slowly and thoroughly. If using a hammer to apply force to any type of chisel or spatula, make sure the force used is minimal otherwise damage to the panel surfaces may occur. 5" Chicago & New York City Only 2 3" Page 6 of 15

7 4a Installing Power 4b 1. Feed power harness through opening (1a) and send downward to base of panel (1b & 1c) or upward to ceiling channel. 1c 1a 1b Single sided block shown. Same for double sided block. 4. Secure the entire assembly to the frame with the mounting clips (4a) and screws (4b) provided. Six (6) clips required. TIP: This is a good time to install a pull string for data/communication wires. 2 3 Page 7 of 15

8 3a Installing the Modular Version 1. Remove masking tape from panel. 2. Attach the receptacles to the power block. Snap the spacer onto the junction box. Attach the appropriate communication receptacle into the spacer then snap the face plate adaptor into position. 3. Attach the receptacle faceplate over the receptacles (3a & b). 2 3b SPACER COMMUNICATION RECEPTACLE RECEPTACLES FACE PLATE ADAPTOR Page 8 of 15

9 Mounting a Base Power Block 1. Remove the top mounting tabs by bending backwards until they snap off. 2. Insert bottom tabs of power block into key slots of bottom rail. 3. Slide power block toward the smaller opening until you hear a snap sound. 2 HOLES IN TRACK WHICH TABS ON POWER BLOCK ARE INSERTED TOP MOUNTING TABS 3 1 THESE TWO TABS ARE LOCATED UNDERNEATH THE POWER BLOCK Page 9 of 15

10 2a MOUNTING TABS Chicago & New York City Hardwire Box and Bracket Assembly 1. Remove knockouts in box prior to installing in frame. 2b NOTE: Chicago & New York City power/communication to be applied to wall system prior to final installation of wall to ceiling grid for maximum flexibility. 2. Without extension covers, feed box into the hole of the frame, making sure mounting tabs are facing upward and towards you. KNOCKOUT 1 HARDWIRE BOX Page 10 of 15

11 Chicago & New York City Hardwire Box and Bracket Assembly (cont.) MOUNTING BRACKET 3. Pre bend mounting bracket at stitching (3a) with end flanges facing outwards. 3a STITCHING END FLANGES Page 11 of 15

12 Chicago & New York City Hardwire Box and Bracket Assembly (cont.) 4. Feed the bracket into the hole of the frame, with the top of bracket facing up. The hardwire box will have to be moved out of the way (downwards) while the bracket is inserted. 5. Mate hardwire box with mounting bracket. The bracket sandwiches the hardwire box (5a). Secure the box to the bracket with mounting screws (5b). 4 5b 5a Page 12 of 15

13 Chicago & New York City Hardwire Box and Bracket Assembly (cont.) 6. Attach conduit to the box. The hardwire box will have to be shifted to make your connections. For easier assembly, power in and power out the same side of the box. 7. Secure the entire assembly to the frame with the mounting clips (7a) and screws (7b) provided. Six (6) clips required. 7a 7b 6 Page 13 of 15

14 Chicago & New York City Hardwire Box and Bracket Assembly (cont.) 8. Attach receptacle extensions to hardwire egress opening. Go to page 8 to complete installation. Note: For proper fit of receptacle remove all ears on receptacle 8 9 Page 14 of 15

15 3+1 Powered by Separate Panels 3+1 Powered by Single Panel Line 1 (Black) Line 2 (Red) Line 3 (Blue) L1/L2/L3 Neutral (White) Systems Ground (Green) LINE 1 (Black) LINE 2 (Red) LINE 3 (Blue) LINE 4 (Pink) L1/L2/L3 Neutral (White) L4 Neutral (Gray) WIRING SCHEMATICS: Line 4 (Pink) L4 Neutral (Gray) Isolated Ground (Gn/Yl) Systems Ground (Green) Isolated Ground (Gn/Yl) NOTE: L-4 may be connected to P-1, P-2, or P-3. NOTE: L-4 should alternate between P-1, P-2, and P-3 to balance circuit loading. ELECTRICAL DATA: 2+2 Powered by Separate Panels 2+2 Powered by 3-Phase Single Panel 2+2 Powered by Split-Phase Panel 120 V 60 HZ 20 Amp USA & CANADA Wiring schematics must be followed to prevent overloading of the neutrals. Line 1 (Black) Line 2 (Red) L1/L2 Neutral (White) System Ground (Green) Line 1 (Black) Line 2 (Red) Line 3 (Blue) Line 4 (Pink) P-1 P-2 Line 1 (Black) Line 2 (Red) Line 3 (Blue) Line 4 (Pink) WARNING: Risk of Fire or Electric Shock: This office furnishing system may be connected to more than one source of supply. All sources must be disconnected prior to any servicing. No single circuit may be powered by more than one source. Line 3 (Blue) Line 4 (Pink) L3/L4 Neutral (Gray) Isolated Ground (Gn/Yl) NOTE: Line 3 or 4 should alternate between phases to balance circuit loading. L1/L2 Neutral (White) L3/L4 Neutral (Gray) System Ground (Green) Isolated Ground (Gn/Yl) NOTE: L-4 should alternate between P-1 and P-2 to balance circuit loading. L1/L2 Neutral (White) L3/L4 Neutral (Gray) System Ground (Green) Isolated Ground (Gn/Yl) 3 SepN Powered by Separate Panels 3 SepN Powered by Single Panel 3 SepN Powered by Split-Phase Panel Line 1 (Black) Line 2 (Red) L1 Neutral (White) L2 Neutral (Gray) Systems Ground (Green) Line 3 (Blue) L3 Neutral (White/Gray) Isolated Ground (Green/Yellow) Line 1 (Black) Line 2 (Red) Line 3 (Blue) L1 Neutral (White) L2 Neutral (Gray) L3 Neutral (White/Gray) Systems Ground (Green) Isolated Ground (Gn/Yl) P-1 P-2 Line 1 (Black) Line 2 (Red) Line 3 (Blue) L1 Neutral (White) L2 Neutral (Gray) L3 Neutral (White/Gray) Systems Ground (Green) Isolated Ground (Gn/Yl) Page 15 of 15

Answer Modular Power. Page 1 of Rev V. Power Kits. Change of Height Harness. Receptical Covers

Answer Modular Power. Page 1 of Rev V. Power Kits. Change of Height Harness. Receptical Covers Answer Modular Power Change of Height Harness Power Kits Receptical Covers NOTE: Unused modular electrical connector openings are not required to be capped. NOTE: The electrician can cut conduit and wire

More information

Avenir & kick Powerway

Avenir & kick Powerway Avenir & kick Powerway System Flag Color -3-Circuit, Shared Neutral and System Ground (SHN) -4-Circuit, 3 with Shared Neutral and System Ground and 1- Isolated Circuit and Ground (3+D) (18" & 24" ONLY)

More information

V.I.A. - Monitor Shroud

V.I.A. - Monitor Shroud V.I.A. - Monitor Shroud NOTE: Installing slatwall above a monitor shroud requires modification of the upper horizontal rail. See V.I.A. Slatwall assembly direction 939502328 for installation process. V.I.A.

More information

Modular Table Power System Installation for Runner Non-folding Plug and Play Tables

Modular Table Power System Installation for Runner Non-folding Plug and Play Tables Modular Table Power System Installation for Runner Non-folding Plug and Play Tables Topic General Safety Warnings Ganging Hardware Electrical Circuits Table of Contents Page End-to-End (Page 4) End-and-Back

More information

B Y R N E 8 - T R A C O V E R V I E W. 1) Introduction. 2) Universally Recognized. 3) Circuitry/Keying

B Y R N E 8 - T R A C O V E R V I E W. 1) Introduction. 2) Universally Recognized. 3) Circuitry/Keying Page 1 of 6 B Y R N E 8 - T R A C O V E R V I E W 1) Introduction Byrne Electrical Specialists, Inc. provides quality, cost effective, innovative power/data distribution solutions. From initial concept

More information

Installing Simplex and Duplex Receptacles into: Series 9000 Structural Panel Series 9000 Energy Management Panel and Worksurface Avenir Power Panel

Installing Simplex and Duplex Receptacles into: Series 9000 Structural Panel Series 9000 Energy Management Panel and Worksurface Avenir Power Panel If you have a problem, question, or request, call your local dealer, or Steelcase Line 1 at 888.STEELCASE (888.783.322) for immediate action by people who want to help you. (Outside the U.S.A., Canada,

More information

Power/Data Instructions. Genius. Movable Walls. September

Power/Data Instructions. Genius. Movable Walls. September Power/Data Genius Movable Walls September 2011 Genius Movable Walls Power and Data in Shell Level 1 Conventional Boxes in Panel (conventional box and conduit) Choose 2x4 box or 4x4 box (shown). Separate

More information

Virtual PUCK for media:scape Kiosk and Answer

Virtual PUCK for media:scape Kiosk and Answer Virtual PUCK for media:scape Kiosk and Answer Note: For VP for media:scape on Kiosk, see page. For VP for media:scape on Answer, see page. # PHILLIPS /6" HEX DRIVE /6", /8" (all tables) plus 5/" (attached

More information

electrics PRODUCT MAP / TABLE OF CONTENTS ELECTRICS & COMMUNICATIONS OVERVIEW POWER ENTRY BASICS PANEL-MOUNTED WORKSTATIONS..

electrics PRODUCT MAP / TABLE OF CONTENTS ELECTRICS & COMMUNICATIONS OVERVIEW POWER ENTRY BASICS PANEL-MOUNTED WORKSTATIONS.. PRODUCT MAP / TABLE OF CONTENTS.................. ELECTRICS & COMMUNICATIONS OVERVIEW............. POWER ENTRY BASICS PANEL-MOUNTED WORKSTATIONS.. POWER & COMMUNICATIONS BASICS PANEL-MOUNTED WORKSTATIONS.....................

More information

DESCRIPTION PRODUCT CODE LIST PRICE DIMENSIONS/INCHES H L D

DESCRIPTION PRODUCT CODE LIST PRICE DIMENSIONS/INCHES H L D EVE8PD - POWER DISTRIBUTION HOUSING Power housing is specified per beam size (e.g. EVE8PD36 is for use in a 36 beam). 8 wire, 4 circuits (2+2 configuration). Accommodates two duplex receptacles per panel

More information

Morrison, Currents and Reff Raceways Morrison, Currents and Reff Raceways

Morrison, Currents and Reff Raceways Morrison, Currents and Reff Raceways 2+2 3+3 Morrison, Currents and Reff Raceways 1 Morrison, Currents and Reff Raceways. More. Better. pioneered 2+2, the office systems raceway with the right balance of convenience power and protected power

More information

KI WIREWORKS WIRE ELECTRICAL SYSTEM INTRODUCTION INFORMATION

KI WIREWORKS WIRE ELECTRICAL SYSTEM INTRODUCTION INFORMATION KI WIREWORKS 810 10-WIRE ELECTRICAL SYSTEM INTRODUCTION INFORMATION 11/1/2005 810 10-WIRE ELECTRICAL SYSTEM COMMONLY ASKED QUESTIONS 11/1/05 1. Q. Is this electrical system a handed/directional system?

More information

Ratchet-Pro Slide Cover

Ratchet-Pro Slide Cover Wiremold/Legrand electrical systems conform to and should be properly grounded in compliance with requirements of the current National Electrical Code or codes administered by local authorities. Ratchet-Pro

More information

lighting, electrics & communications

lighting, electrics & communications lighting, electrics & communications P RO D U C T M A P / TA B L E C O N T E N T S.....................4 L I G H T I N G, E L E C T R I C S & C O M M U N I C AT I O N S O V E RV I E W....4 4 L I G H T

More information

lighting, electrics & communications

lighting, electrics & communications lighting, electrics & communications PRODUCT MAP / TABLE OF CONTENTS.................. LIGHTING, ELECTRICS & COMMUNICATIONS OVERVIEW.... LIGHTING BASICS................................. MODULAR DESK APPLICATIONS:

More information

lighting, electrics & communications

lighting, electrics & communications lighting, electrics & communications ELECTRICS & COMMUNICATIONS OVERVIEW............. LIGHTING BASICS................................. 205 POWER POLE BASICS............................... POWER ENTRY FROM

More information

Phase Loss Protection Upgrade. Phase Loss Protection Upgrade. In this bulletin:

Phase Loss Protection Upgrade. Phase Loss Protection Upgrade. In this bulletin: Phase Loss Protection Upgrade In this bulletin: Introduction... 2 Purpose... 2 General... 2 Applicability... 2 HD3070 Phase Loss Protection Upgrade Kit Parts... 2 Preparation... 4 Install the Phase Loss

More information

Installation/Operating Instructions 220V VCB Silhouette/Series E Electric Video Conferencing Background by Draper

Installation/Operating Instructions 220V VCB Silhouette/Series E Electric Video Conferencing Background by Draper Installation/Operating Instructions 220V VCB Silhouette/Series E Electric Video Conferencing Background by Draper Caution 1 Read instructions through completely before proceeding; keep them for future

More information

Gateway Profile 4 service guide

Gateway Profile 4 service guide Gateway Profile 4 service guide Customizing Troubleshooting Contents Replacing Components in Your Gateway Profile 4.................. 1 About this guide.....................................................

More information

lighting, electrics & communications

lighting, electrics & communications lighting, electrics & communications P RO D U C T M A P...................................2 9 0 289 L I G H T I N G, E L E C T R I C S & C O M M U N I C AT I O N S O V E RV I E W....2 9 4 L I G H T I N

More information

lighting, electrics & communications

lighting, electrics & communications lighting, electrics & communications P RO D U C T M A P................................... 3 1 6 L I G H T I N G, E L E C T R I C S & C O M M U N I C AT I O N S B A S I C S...... 3 1 9 L I G H T I N G

More information

SURFACE CONTROLTrack INSTALLATION INSTRUCTIONS

SURFACE CONTROLTrack INSTALLATION INSTRUCTIONS SURFACE CONTROLTrack INSTALLATION INSTRUCTIONS IMPORTANT SAFETY INSTRUCTIONS - For use with CONTROLTrack System Only When installing or using this track system, basic safety precautions should always be

More information

To connect the AC adapter:

To connect the AC adapter: Replacing the AC Adapter Replacing the AC Adapter 3 Plug the power cord into a wall outlet. The power indicator turns on. To connect the AC adapter: Connect the power cord to the AC adapter. Power indicator

More information

Configurable Output Distribution. 120V / 208V / 240V 60Hz. User Manual English

Configurable Output Distribution. 120V / 208V / 240V 60Hz. User Manual English Configurable Output Distribution 120V / 208V / 240V 60Hz User Manual English TABLE OF CONTENTS IMPORTANT SAFETY INSTRUCTIONS.......................... 1 GLOSSARY OF SYMBOLS....................................

More information

A-dec 570L Dental Light on a DCS System INSTALLATION GUIDE

A-dec 570L Dental Light on a DCS System INSTALLATION GUIDE A-dec 570L Dental Light on a DCS System INSTALLATION GUIDE C ONTENTS Choose an Installation Guide...... Before You Begin.............. 3 Disconnect the Light Cable........ 3 Cut the Light Cable............

More information

Cisco CRS 3-Phase AC Power Distribution Unit Installation Guide 2. Cisco CRS 3-Phase AC Power Distribution Unit 2

Cisco CRS 3-Phase AC Power Distribution Unit Installation Guide 2. Cisco CRS 3-Phase AC Power Distribution Unit 2 Cisco CRS 3-Phase AC Power Distribution Unit Installation Guide Cisco CRS 3-Phase AC Power Distribution Unit Installation Guide 2 Cisco CRS 3-Phase AC Power Distribution Unit 2 Revised: November 18, 2016,

More information

USBCNC USB Disk Key reader for CNC Controls Machine Mount instructions

USBCNC USB Disk Key reader for CNC Controls Machine Mount instructions USBCNC USB Disk Key reader for CNC Controls Machine Mount instructions 2008-2015 Calmotion LLC, All rights reserved Calmotion LLC 21720 Marilla St. Chatsworth, CA 91311 www.calmotion.com Introduction This

More information

Rack Installation Instructions

Rack Installation Instructions Rack Installation Instructions For System Storage EXP2512 and EXP2524 Express Storage Enclosures Use the instructions in this document to install an IBM System Storage EXP2512 Express Storage Enclosure

More information

Removing and Replacing Parts

Removing and Replacing Parts Removing and Replacing Parts Preparing to Work Inside the Computer Recommended Tools Screw Identification System Components Hard Drive Fixed Optical Drive Media Bay Devices Memory Modules Mini PCI Card

More information

USBCNC-SW USB Disk Key reader for CNC Controls Machine Mount instructions for Universal Switcher Version

USBCNC-SW USB Disk Key reader for CNC Controls Machine Mount instructions for Universal Switcher Version USBCNC-SW USB Disk Key reader for CNC Controls Machine Mount instructions for Universal Switcher Version 2015 Calmotion LLC, All rights reserved Calmotion LLC 21720 Marilla Street Chatsworth, CA 91311

More information

System Storage EXP3000 Rack Installation Instructions

System Storage EXP3000 Rack Installation Instructions System Storage EXP3000 Rack Installation Instructions Review the documentation that comes with your rack cabinet for safety and cabling information. When you install the IBM System Storage EXP3000 in a

More information

If technical support is required, please contact Advent Technical Support at

If technical support is required, please contact Advent Technical Support at Document 128-9011 Created 11/21/11 Kit Contents: Item # Qty. Component Description 1 2 Monitor Assembly 2 2 Remote Control 3 1 Cables # 3 4 1 Metal Wire Puller 5 1 Power Cord # 9 6 1 Owners Manual 7 2

More information

ipod Classic Headphone Jack & Hold Switch Replacement

ipod Classic Headphone Jack & Hold Switch Replacement ipod Classic Headphone Jack & Hold Switch Replacement Replace Headphone Jack & Hold Switch to fix no audio and/or no unlock Written By: irobot ifixit CC BY-NC-SA www.ifixit.com Page 1 of 22 INTRODUCTION

More information

WINSTA. Full Line Catalog 2008/2009

WINSTA. Full Line Catalog 2008/2009 WINSTA Full Line Catalog 2008/2009 5 Contents FULL LINE CATALOG W4, Volume 1 Rail-Mounted Terminal Block Systems FULL LINE CATALOG W4 Rail-Mounted Terminal Blocks Volume 1 X-COM -SYSTEM Terminal Strips

More information

Electrical Accessories

Electrical Accessories 2017 Price List and Specifications Brodart Co. Contract Furniture - Made in USA 280 North Road, Clinton County Industrial Park McElhattan, PA 17748 Toll-Free: 888-521-1884 E-Mail: furniture@brodart.com

More information

AP-120 Series AP Mounting Kit

AP-120 Series AP Mounting Kit AP-120 Series AP Mounting Kit Installation Guide The AP-120 series mounting kit provides additional mounting options for the AP-120 series wireless access points. The mounting kit includes the following

More information

User s Guide. Includes Mounting, Installation, and Product Registration nd Avenue NE Arlington, WA USA (+1)

User s Guide. Includes Mounting, Installation, and Product Registration nd Avenue NE Arlington, WA USA (+1) User s Guide Includes Mounting, Installation, and Product Registration 500 19009 62nd Avenue NE Arlington, WA USA (+1) 360-435-6030 European Sales Office Barcelona, España (+34) 600-843-845 www.outbackpower.com

More information

ATTENTION: OBSERVE PRECAUTIONS FOR HANDLING ESD-SENSITIVE DEVICES

ATTENTION: OBSERVE PRECAUTIONS FOR HANDLING ESD-SENSITIVE DEVICES Hard Drive Removal IMPORTANT NOTE: If you are replacing a PATA hard drive with a SATA hard drive, please see PATA to SATA Hard Drive Conversion. Hard Drive Identification: To determine whether your hard

More information

Service & Maintenance

Service & Maintenance Service & Maintenance Internal Amplifier External (Peavey) Amplifier Core & HDD Monitor UPS Dollar Bill Acceptor Coin Mechanism Cleaning Fans & Filter G1-1 Internal Amplifier Amplifier Removal 1. Disconnect

More information

SAVE THESE INSTRUCTIONS

SAVE THESE INSTRUCTIONS READ AND FOLLOW ALL SAFETY INSTRUCTIONS! SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION IMPORTANT SAFEGUARDS! When using electrical equipment, basic safety precautions should always be

More information

A-dec 584 Monitor Mount on a Central Cabinet

A-dec 584 Monitor Mount on a Central Cabinet Installation Guide A-dec 584 Monitor Mount on a Central Cabinet Before You Begin This procedure applies to the A-dec Inspire TM 592 Central Console and the standard and tall Preference cabinet central

More information

E1135C PDU and Pod Upgrade Procedure

E1135C PDU and Pod Upgrade Procedure E4030-90010 Rev. B 12/2003 In this Document... Tools Needed, 2 Contents of the Upgrade Kits, 2 Installation Procedures, 4 Verifying the Power Option of the New PDU, 4 Removing the PDU from the Support

More information

ILC LightLEEDer MicroLite 1000P Retrofit Installation

ILC LightLEEDer MicroLite 1000P Retrofit Installation ILC LightLEEDer MicroLite 1000P Retrofit Installation Congratulations on the purchase of your new ILC LightLEEDer Retrofit System. The ILC LightLEEDer MicroLite Retrofit System is designed for the replacement

More information

Installing 6 Indexer: PRS Standard Tools

Installing 6 Indexer: PRS Standard Tools 888-680-4466 ShopBotTools.com Installing 6 Indexer: PRS Standard Tools Copyright 2016 ShopBot Tools, Inc. page 1 Copyright 2016 ShopBot Tools, Inc. page 2 Table of Contents Overview...5 Installing the

More information

Lighting PowerPincher Installation Instructions

Lighting PowerPincher Installation Instructions PowerPincher Installation Instructions Lighting PowerPincher Installation Instructions Description The PowerPincher is an advanced energy saving control system, designed for general office use. It combines

More information

Trig Planning Guide. December 2012

Trig Planning Guide. December 2012 Trig Planning Guide December 2012 Table of Contents Statement of Line Trig Applications - Conventional and Integration Specification Information Statement of Line Desks and Work Surfaces Support Options

More information

Rack Mount Power Supplies

Rack Mount Power Supplies Rack Mount Power Supplies Installation Guide Models Include: VertiLine33D - 12VDC @ 8A - Sixteen (16) PTC protected outputs VertiLine33TD - 12VDC @ 16A - Sixteen (16) PTC protected outputs VertiLine63D

More information

Home Automation, Inc. Model 53A00-1. OmniTouch 5.7 Touchscreen with Video

Home Automation, Inc. Model 53A00-1. OmniTouch 5.7 Touchscreen with Video Home Automation, Inc. Model 53A00-1 OmniTouch 5.7 Touchscreen with Video Installation Manual Document Number 53I00-1 Rev A June, 2007 FCC NOTICE This device complies with FCC Rules Part 15. Operation is

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS CONSOLE CONNECTOR KIT 7830 FOR USE WITH: LESLIE Speaker Model 130 Various single and double channel organs INSTALLATION INSTRUCTIONS KIT CONTENT Console Connector 137283 Switch Assembly, Cable Assembly,

More information

STC7D. Digital Time Clock for TRC500 & TRC800. Installation, Operation, and Maintenance Manual

STC7D. Digital Time Clock for TRC500 & TRC800. Installation, Operation, and Maintenance Manual STC7D Digital Time Clock for TRC500 & TRC800 Installation, Operation, and Maintenance Manual READ AND SAVE THESE INSTRUCTIONS The purpose of this manual is to aid in the proper installation and operation

More information

PIX 515/515E. PIX 515/515E Product Overview CHAPTER

PIX 515/515E. PIX 515/515E Product Overview CHAPTER CHAPTER 4 PIX 515/515E This chapter describes how to install the PIX 515/515E, and includes the following sections: PIX 515/515E Product Overview Installing a PIX 515/515E PIX 515/515E Feature Licenses

More information

PXC Compact Unitary Equipment Controller (UEC)

PXC Compact Unitary Equipment Controller (UEC) Document No. 553-169 PXC Compact Unitary Equipment Controller (UEC) Product Description The PXC Unitary Equipment Controller (UEC) is an MS/TP device that can be configured as a programmable, stand-alone

More information

Cone Beam Volumetric Tomography and Panoramic Dental Imaging System

Cone Beam Volumetric Tomography and Panoramic Dental Imaging System Installation Manual Installation Manual Installation Manual Installation Manual Installation Manual Cone Beam Volumetric Tomography and Panoramic Dental Imaging System Gendex CB-500 Installation Manual

More information

ON-FLOOR WIREWAY PRICELIST AUGUST 1, 2017

ON-FLOOR WIREWAY PRICELIST AUGUST 1, 2017 PRICELIST AUGUST 1, 2017 POWER AND TELECOM SOLUTION FOR TOP-OF-FLOORING INSTALLATION The new Trac On-Floor Wireway systems install directly on top of any type of flooring. They are the industry s newest

More information

Connector System for Fluorescent Lighting Fixtures. Connectors for In-Line Mounting of Fluorescent Lighting Fixtures. Fully Polarized Connectors

Connector System for Fluorescent Lighting Fixtures. Connectors for In-Line Mounting of Fluorescent Lighting Fixtures. Fully Polarized Connectors Connector System for Fluorescent Lighting Fixtures Connectors for In-Line Mounting of Fluorescent Lighting Fixtures Fully Polarized Connectors Luminaire Disconnect Connectors Pluggable Lighting Connectors

More information

Emerald Cubicle System. Spec Sheet. Emerald 39,52, 65 H. skutchi.com cubicles.cc. Vol DESIGNS. inc.

Emerald Cubicle System. Spec Sheet. Emerald 39,52, 65 H. skutchi.com cubicles.cc. Vol DESIGNS. inc. Emerald Cubicle System Spec Sheet 2018 Emerald 39,52, 65 H skutchi.com cubicles.cc Vol. 1 2018 Emerald Cubicles The diverse Emerald System has endless solutions for your office. Whether you are looking

More information

Topic: TB No.: Date: Aug/2017. Model UC4, UC10 & UC45 twin pump variants Regulated 24V Pump Power supply upgrade OVERVIEW

Topic: TB No.: Date: Aug/2017. Model UC4, UC10 & UC45 twin pump variants Regulated 24V Pump Power supply upgrade OVERVIEW Topic: TB No.: 10041 Date: Aug/2017 Affected Machines: UC4/UC10 &45 variants Priority: Medium Created By: Gareth Fitzpatrick From Serial No.:

More information

Assembly Instructions for #5630 Medication PalWOW

Assembly Instructions for #5630 Medication PalWOW Assembly Instructions for #5630 Medication PalWOW Before assembling, please familiarize yourself with all the parts and check to make sure you have all the parts as listed below. A B A & B - The box in

More information

Electrical Management System (EMS) EMS-HW30C & EMS-HW50C

Electrical Management System (EMS) EMS-HW30C & EMS-HW50C Electrical Management System (EMS) EMS-HW30C & EMS-HW50C Installation & Operating Guide for: Model EMS-HW30C Rated at 120V/30A and Model EMS-HW50C Rated at 240V/50A Surgio Says Lifetime Warranty on all

More information

The power behind competitiveness. Delta Infrasuite Power Management. Power Distribution Unit. User Manual.

The power behind competitiveness. Delta Infrasuite Power Management. Power Distribution Unit. User Manual. The power behind competitiveness Delta Infrasuite Power Management Power Distribution Unit User Manual www.deltapowersolutions.com Save This Manual This manual contains important instructions and warnings

More information

OnePlus 5 Screen and Digitizer Assembly Replacement

OnePlus 5 Screen and Digitizer Assembly Replacement OnePlus 5 Screen and Digitizer Assembly Replacement Follow this guide to replace the screen and digitizer for the OnePlus 5. This replaces the screen as well as the frame it is attached to. Written By:

More information

lighting, electrics & communications

lighting, electrics & communications lighting, electrics & communications LIGHTING, ELECTRICS & COMMUNICATIONS OVERVIEW.... 209 LIGHTING BASICS................................. 210 207 MODULAR DESKS APPLICATIONS: 207 POWER & DATA DISTRIBUTION.......................

More information

3M Indoor Protected Building Entrance Terminal 4788V-QCS Series

3M Indoor Protected Building Entrance Terminal 4788V-QCS Series The Network of Networks. 3M Indoor Protected Building Entrance Terminal 4788V-QCS Series with 3M Quick Connect System (QCS) 2811 Dry Flame Retardant Block for Field-Terminated Building Cables Instructions

More information

Basketball Shot Clock Set LX2180 Manual

Basketball Shot Clock Set LX2180 Manual Basketball Shot Clock Set LX2180 Manual 72 Industrial Boulevard Wrightsville, GA 31096 Phone: (800) 445-7843 Fax: (800) 864-0212 www.electro-mech.com LX2180 Revision 5 February 8, 2013 Table of Contents

More information

Temperature. Power requirements. Weight. Dimensions

Temperature. Power requirements. Weight. Dimensions Installing the Tracer Summit BMTX Building Control Unit Ordering numbers: BMTX001AAB000, BMTX001AAB010, BMTX001AAB001, BMTX001AAB011, BMTX001BAB000, BMTX001BAB010, BMTX001BAB001, BMTX001BAB011, BMTX001DAB000

More information

Installation Guide. Retrofit Kit for USB Ready Intraoral Systems

Installation Guide. Retrofit Kit for USB Ready Intraoral Systems Installation Guide Retrofit Kit for USB Ready Intraoral Systems Table of Contents Wall-Mount Retrofit Kit... 2 Introduction... 2 Connecting the Articulating and Horizontal Arm Cables... 2 Installing the

More information

PM Series Power Meter

PM Series Power Meter PM Series Power Meter Quick Setup Guide - PMC-1000, PMC- 1001, PMM-1000, PMB-1960 Safety Information DANGER! HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Follow safe electrical work practices. See

More information

Signal Adapter. Signal Output. Power Input. Modell-Zug Elektronix Signal Adapter U.S.A. Momentary. Auxillary. Switch. Outputs

Signal Adapter. Signal Output. Power Input. Modell-Zug Elektronix Signal Adapter U.S.A. Momentary. Auxillary. Switch. Outputs Adapter 1. Introduction Thank you for purchasing this product. The Adapter was specially designed to provide universal operation of the new generation of Märklin color light signals 74371, 74380, and 74391.

More information

4888 and 4988 Outdoor Protected Entrance Terminals

4888 and 4988 Outdoor Protected Entrance Terminals 4888 and 4988 Outdoor Protected Entrance Terminals Underwriters Laboratories (UL) Listed Instructions January 1997 34-7031-7272-5 Revision C Contents: 1.0 General... 1 2.0 Accessories... 2 3.0 Protector

More information

With its tamper-resistant design, the

With its tamper-resistant design, the Dual-Channel 40N2 Series Nonmetallic Raceway Systems CableSmart Series Nonmetallic Raceway With its tamper-resistant design, the CableSmart 40N2 Series Raceway is ideal for schools or office settings,

More information

Flat Screen Garage. Table System Planning Guide WORKING FOR YOU

Flat Screen Garage. Table System Planning Guide WORKING FOR YOU Flat Screen Garage Table System Planning Guide ORKING FOR YOU Introduction Bring a new level of performance to any room with KI s Flat Screen Garage. This versatile system does double duty to make the

More information

1. Mount the echo and tremolo control switches under the keyboard shelf, in a position convenient for the organist.

1. Mount the echo and tremolo control switches under the keyboard shelf, in a position convenient for the organist. CONSOLE CONNECTOR KIT 8101 INSTALLATION INSTRUCTIONS FOR USE WITH: HAMMOND Organ Models A-100, D-100, RT2, RT3 LESLIE Speaker Models 122, 122RV KIT CONTENT Console Connector Assembly 047357 Echo Control

More information

Mac Mini Mid 2011 SSD Dual Drive Installation

Mac Mini Mid 2011 SSD Dual Drive Installation Mac Mini Mid 2011 SSD Dual Drive Installation Install a second hard drive in your mid 2011 Mac Mini. Written By: Dozuki System 2017 guides.crucial.com Page 1 of 19 INTRODUCTION Use this guide to install

More information

READ COMPLETELY BEFORE INSTALLING!!!

READ COMPLETELY BEFORE INSTALLING!!! DOWNSHOT ECONOMIZER INSTALL INSTALLATION INSTRUCTIONS FOR 3-12.5 TON YORK PREDATOR GEN 7 OR NEWER ECONOMIZER DOWNSHOT CONFIGURATION CAS PART NUMBER 1023535 READ COMPLETELY BEFORE INSTALLING!!! IS NOT RESPONSIBLE

More information

QUICK SETUP GUIDE PMC-1000, PMC-1001, PMM-1000, PMB PM Series Power Meter. Safety Information. Equipment Maintenance and Service.

QUICK SETUP GUIDE PMC-1000, PMC-1001, PMM-1000, PMB PM Series Power Meter. Safety Information. Equipment Maintenance and Service. PM Series Power Meter QUICK SETUP GUIDE PMC-1000, PMC-1001, PMM-1000, PMB-1960 Safety Information DANGER! HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Follow safe electrical work practices. See NFPA

More information

Haworth Power Technical Sheets January 2018

Haworth Power Technical Sheets January 2018 Haworth Power Technical Sheets January 2018 Includes Accessories This page intentionally left blank. Table of Contents Desk Top Port Power Tap Cord Power Tap Conduit Enchanced Power Module Flip Top Unit

More information

U-SERIES SPECIFICATION GUIDE

U-SERIES SPECIFICATION GUIDE U-SERIES SPECIFICATION GUIDE Connectivity with flexibility For more product information visit connectrac.com, call us at 877-480 - 5637 or email us at info@connectrac.com ADA COMPLIANT - U.L. TESTED AND

More information

Smartspace Benching System

Smartspace Benching System SIN 711-2 Smartspace Benching System With the increase in office collaboration, comes an easy-to-install benching solution. Now that's smart thinking. Easily integrate power trough allows every workstation

More information

PAR+ & MSC+ Controller. Installation Manual

PAR+ & MSC+ Controller. Installation Manual PAR+ & MSC+ Controller Installation Manual Contents Introduction... 1 System Configuration...1 Parts List and Tools Required for Installation...1 Installation Checklist...1 Mount Controller Pedestal on

More information

AB-2D AB-2D SPEAKER A,B OR A+B SELECTOR INSTALLATION & OPERATION GUIDE

AB-2D AB-2D SPEAKER A,B OR A+B SELECTOR INSTALLATION & OPERATION GUIDE M O D E L AB-2D AB-2D SPEAKER A,B OR A+B SELECTOR INSTALLATION & OPERATION GUIDE AB-2D Speaker/Amplifier Selector TABLE OF CONTENTS Introduction 1 Features and Benefits 1 Installation Considerations 3

More information

SM (SURFACE MOUNTED) WIREWAY: I SERIES

SM (SURFACE MOUNTED) WIREWAY: I SERIES SM (SURFACE MOUNTED) WIREWAY: I SERIES DUPLEX POWER AND AV / TELECOM ANYWHERE The new Connectrac SM (Surface Mounted) Wireway installs directly onto any type of flooring. It s the industry s newest alternative

More information

EcoFlex LED Neon Manual

EcoFlex LED Neon Manual Manual Part number: LN-ECO-XXXX-10m from Environmental Lights is one of the most flexible and cost-effective members of our line of LED Neon products. It allows you to achieve the creative potential of

More information

Navigation interface for Jeep GC 5 RA2 NTV-KIT581

Navigation interface for Jeep GC 5 RA2 NTV-KIT581 3950 NW 120 th Ave, Coral Springs, FL 33065 TEL 561-955-9770 FAX 561-955-9760 NNG-Jeep GC Navigation interface for Jeep GC 5 RA2 NTV-KIT581 NNG-JEEP GC Kit Content 5 1 6 4 7 2 3 1. 2. 3. 4. 5. 6. 7. 8.

More information

CableSmart Series Nonmetallic Raceway

CableSmart Series Nonmetallic Raceway CableSmart Series Nonmetallic Raceway Dual-Channel 40N2 Series Nonmetallic Raceway System FIBER OPTIC CAT5 Wiremold CableSmart 40N2 Series Raceway is a large capacity nonmetallic raceway system that offers

More information

ibook G3 14" Top Shield Replacement

ibook G3 14 Top Shield Replacement Written By: irobot ifixit CC BY-NC-SA www.ifixit.com Page 1 of 18 INTRODUCTION The metallic top shield protects the logic board from electromagnetic interference. TOOLS: Coin (1) Paper Clip (1) Phillips

More information

- ELV OVERVIEW. InstallationGuide SUPPLIED PARTS RELATED PARTS. Brackets Fixtures. Other. 1 of 9 IG-STR9-ELV

- ELV OVERVIEW. InstallationGuide SUPPLIED PARTS RELATED PARTS. Brackets Fixtures. Other. 1 of 9 IG-STR9-ELV OVERVIEW The STR9 ELV is a long run, low power, linear surface mount LED lighting system designed for exterior architectural lighting applications. This guide contains important information on planning

More information

for a perfect electrical installation. The range of rail-mounted terminal blocks

for a perfect electrical installation. The range of rail-mounted terminal blocks The range of rail-mounted terminal blocks for a perfect electrical installation. The range of rail-mounted terminal blocks for a perfect electrical installation. The new standard for rail-mounted terminal

More information

Secured Series: Hub Plus Kit Single Door Controller Package Installation Manual

Secured Series: Hub Plus Kit Single Door Controller Package Installation Manual Secured Series: Hub Plus Kit Single Door Controller Package Installation Manual This package is designed to simplify the connections to our Secured Series Hub Plus Controller. This will translate into

More information

RECOMMENDED TOOLS PERSONAL & VEHICLE PROTECTION MASKING TAPE

RECOMMENDED TOOLS PERSONAL & VEHICLE PROTECTION MASKING TAPE GUIDE PART NUMBER: 250-7616 GM SOFT TOUCH NAVIGATION SYSTEM GENERAL APPLICABILITY 2013- RAV4 KIT CONTENTS ITEM QTY DESCRIPTION 1 1 NAVIGATION INTERFACE MODULE 2 1 VEHICLE INTERFACE T-HARNESS 3 1 LCD/GPS

More information

Upgrading LVDS Cables Instruction Sheet

Upgrading LVDS Cables Instruction Sheet Upgrading LVDS Cables Instruction Sheet INTRODUCTION Use the following instructions to replace the LVDS cables in CP2000-M/MR projectors. The new cables are slightly longer in length and allow for better

More information

4188, 4288, 4288-S and 4688 Protected Entrance Terminals

4188, 4288, 4288-S and 4688 Protected Entrance Terminals 4188, 4288, 4288-S and 4688 Protected Entrance Terminals Instructions Underwriters Laboratories (UL) Listed January 1997 34-7041-3837-8 Revision A Contents: 1.0 General... 1 2.0 Accessories... 2 3.0 Protector

More information

nls Product List 1st February, 2014 Tel: Fax: Coombes Drive, Penrith, NSW, 2750 Australia

nls Product List 1st February, 2014 Tel: Fax: Coombes Drive, Penrith, NSW, 2750 Australia 15 Coombes Drive, Penrith, NSW, 2750 Australia 15 Coombes Drive Penrith NSW 2750 Tel: 02-4732 5444 Fax: 02-4732 6600 Email: sales@nlslight.com.au Product list for Electrical Accessories Code Item Inner

More information

CHANNEL LETTER LIGHTING UNIQUE LIGHTING SOLUTIONS RETROFIT INSTALLATION GUIDE

CHANNEL LETTER LIGHTING UNIQUE LIGHTING SOLUTIONS RETROFIT INSTALLATION GUIDE UNIQUE LIGHTING SOLUTIONS LIGHTING WARNING -Installation must only be performed by a licensed electrician. -To prevent death, injury or damage to property this product must be installed in accordance to

More information

DOCKING STATION SPECIFICATIONS

DOCKING STATION SPECIFICATIONS ONE PERSON STATION Power Outlets Data Jack Plate Mouse Brackets Front Covers Cable Holes Cable Holes Overview: The Docking Station distributes power, data, and laptop storage to each user. It also offers

More information

ipod Classic Click Wheel Replacement Written By: irobot ifixit CC BY-NC-SA Page 1 of 25

ipod Classic Click Wheel Replacement Written By: irobot ifixit CC BY-NC-SA   Page 1 of 25 ipod Classic Click Wheel Replacement Written By: irobot ifixit CC BY-NC-SA www.ifixit.com Page 1 of 25 INTRODUCTION The click wheel receives the feedback of your fingers and transmits it to the logic board.

More information

Installing the PSU for the S50 and S50N

Installing the PSU for the S50 and S50N Installing the PSU for the S50 and S50N Caution: Use only the power cords supplied with the power supply. Do not supply power to your S50 or S50N system until the power supply and modules have been installed.

More information

MCG Surge Protection

MCG Surge Protection 299-700-33B 299-700-33A MCG Surge Protection Installation/Operating Instructions for MCG 500 Series Important Warranty Information MCG surge protectors are designed to work at specific voltages and configurations,

More information

Power Base AI. Power Base AI. Technical Sheets

Power Base AI. Power Base AI. Technical Sheets Power Base AI Power Base AI Technical Sheets odular Electrical System System Overview Haworth s Power Base AI modular electrical system provides a flexible, reconfigurable power distribution infrastructure

More information

Instruction Manual. Electrical Management System (EMS) EMS-HW30C & EMS-HW50C

Instruction Manual. Electrical Management System (EMS) EMS-HW30C & EMS-HW50C Instruction Manual Electrical Management System (EMS) EMS-HW30C & EMS-HW50C EMS-HW50C EMS-HW30C! CAUTION These instructions are intended to provide assistance with the installation of this product, and

More information

Operation and Maintenance Manual

Operation and Maintenance Manual VM Series Operation and Maintenance Manual VM - Voltage Monitor VM-100-24 V VM-100-48 V VM-100-125 V VM-100-250 V EAGLE EYE POWER SOLUTIONS All Rights Reserved. 1 The Voltage Monitor series reads battery

More information