EXCELL PRECISION CO., LTD.

Size: px
Start display at page:

Download "EXCELL PRECISION CO., LTD."

Transcription

1 Excell Precision Limited 24. All rights reserved Worldwide. The information contained herein is the property of Excell Precision Limited and is supplied without liability for errors or omissions. No part may be reproduced or used except as authorised by contract or other written permission. The copyright and the foregoing restriction on reproduction and use extend to all media in which the information may be embodied.

2

3 EXCELL PRECISION CO., LTD. TABLE OF CONTENTS SAFETY...3 CHAPTER 1 SPECIFICATIONS...4 CHAPTER 2 OPERATION GUIDE...5 CHAPTER 3 FRONT AND REAR PANEL FRONT PANEL REAR PANEL...8 CHAPTER 4 INSTALLATION LOAD CELL INDICATOR INSTALLATION AND DIMENSIONS...9 CHAPTER 5 CAPACITY CALIBRATION PARAMETER SETTING Flow Diagram Description CALIBRATION SETTING Calibration Procedure Zero Calibration Weight Calibration Linearity Calibration PASSWORD SETTING ERROR MESSAGES...19 CHAPTER 6 ANIMAL SCALE FUNCTION SETTING...2 CHAPTER 7 INTERFACES OP-1 RS-422 & RS-485 INTERFACE OP-2 PARALLEL BCD OUTPUT OP-3 ANALOGUE CURRENT / VOLTAGE OUTPUT INTERFACE OP-5 PARALLEL PRINTER OUTPUT & RS-232 & CURRENT LOOP OP-6 RS-232 & CURRENT LOOP OP-7 RS-232, CURRENT LOOP & DATA CLOCK OUTPUT OP-8 CONTROL I /O (2I /4O) INTERFACE...32 CHAPTER 8 MAINTENANCE RESET ALL PARAMETERS BACK TO DEFAULT RESET GENERAL FUNCTION PARAMETERS BACK TO DEFAULT SELF-DIAGNOSIS MODE Digit Display and LED Status Light Diagnosis Keyboard and Calibration ON / OFF Switch Diagnosis RS-232 Serial Output / Input Interface Diagnosis ( OP-6 )

4 8-3-4 BCD Parallel Output Interface Diagnosis ( OP-2 ) Analogue Current Output Interface Diagnosis ( OP-3 ) Parallel Printer Interface Diagnosis ( OP-5 ) Main Board EEPROM Memory Diagnosis OP-8 Control I /O (2I /4O) Diagnosis...38 CHAPTER 9 FUNCTION TABLE GENERAL FUNCTION OP-1, OP-6, OP-7 INTERFACE FUNCTION OP-2 BCD OUTPUT INTERFACE FUNCTION OP-3 ANALOGUE OUTPUT INTERFACE FUNCTION OP-5 PARALLEL PRINTER OUTPUT INTERFACE FUNCTION OP-8 CONTROL I /O (2I /4O) INTERFACE FUNCTION

5 rsafety! & Disconnect the main power supply before opening the indicator housing or installing / un-installing the instrument. & Keep the instrument in a cool dry place. Do not store it at high temperatures. & The operating ambient temperature range is -1 C ~ +4 C. & F.G. is the ground (electrical earth) connection. (Ground impedance < 1Ω) Avoid connecting the ground connection with other equipment. The indicator must always be connected to the electrical ground (earth) for safe operation. 3

6 CHAPTER 1 SPECIFICATIONS ANALOG DATA Input sensitivity Max. load cell input voltage Load cell excitation.12 μv/d or more -1mV 16mV DC 5V Load cell current 12mA ( 8-35Ω load cells ) Temperature coefficient Zero ppm/ ( -1 4 ) Span ppm/ ( -1 4 ) Non-linearity ±.2%FS Input noise 8nV Hz f = 1KHz Input impedance 25GΩ Internal resolution 52 Max. display resolution Conversion rate 1 times/sec (max.) DIGITAL DATA Display section Status display section 7 digits, red LED, 2mm (.8 ), 7-segment 6 character display, red LED Display frequency (times/sec) Selectable, Max 5 Display range to Min. division 1, 2, 5, 1, 2, 5 Status display Power, Zero, Motion, Gross, Net, Tare Decimal point Selectable,.,.,.,. GENERAL SPECIFICATIONS Power requirements (AC/W) AC1V 24V -15%~+1% 1W Operating temperature range Operating humidity range <85% R.H Physical dimensions 21(W) 18 (H) 27(D) Weight OPTIONS OP-1 RS422 / RS-485 OP-2-1 Parallel BCD Output ( TTL ) OP-2-2 Parallel BCD Output ( O.C. ) OP-3 Analog Output ( 4-2mA ) About 1.7 kg OP-5 Parallel Printer Output / RS232C & Current Loop OP-6 RS-232C & Current Loop OP-7 RS-232C & Current Loop & Data Clock Output OP-8 Control I / O ( 2I / 4O) 4

7 CHAPTER 2 OPERATION GUIDE FUNCTION OPERATION PROCEDURE DESCRIPTION General function setting Press and hold the then press the Fn key, Refer to Chapter 9 Functions Table to set FUNC. ~ FUNC. 7 Capacity parameter setting Calibration Self-diagnosis mode Reset all parameters back to default Switch the capacity calibration switch to ON and then press the Fn Fn Switch the capacity calibration switch to ON and then press the Turn on the indicator, press and hold CAL and the indicator starts the self-test procedure. Switch the calibration switch to ON, turn on the indicator, press and hold and while the indicator is in the self-testing sequence Turn on the indicator, Set the parameter for decimal point, max. capacity, min. division, zero tracking, unstable detection Refer to < 5-1 > Parameter Setting Calibration procedures. Refer to < 5-2 > Calibration Setting Refer to < 8-3 > Self-diagnosis Mode for details Refer to < 8-1 > Reset All Parameter Back to Default Reset general function parameter back to factory standard setting Display software version press and hold by pressing Fn, followed while the indicator is in the self-testing sequence Turn on the indicator, press and hold the CAL while the indicator is in the self-test sequence Refer to < 8-2 > Reset General Function Parameter Back to Default The main display section displays the software version, press any key to exit Function parameter setting Press and hold, followed by pressing CAL Hi, Lo, Zero Band parameter setting 5

8 4 Operation of Keys in the Setting Mode Cycles the flashing character from to 9 Shifts the flashing character to the left Cycles the flashing character from 9 to Save data Shifts the flashing character to the right Quit / Exit 6

9 CHAPTER 3 FRONT AND REAR PANEL 3-1 FRONT PANEL Racer Plus POWER ZERO MOTION GROSS NET TARE ENTERED ON 3 1 MAIN DISPLAY Displays gross weight or net weight 2 STATUS INDICATION LIGHTS POWER : Power Indication ZERO : Zero status indication MOTION : Unstable weighing indication GROSS : Main display section currently displays gross wt. NET : Main display section currently displays net wt. TARE ENTERED : Tare indication 3 KEYS 1) Standby mode ON/OFF 2) When setting the parameter or calibration, it works as quit or exit from setting Fn CAL 1) Sets weight back to zero 2) When setting the parameter or calibration, it cycles from to 9 1) Tare function 2) When setting the parameter or calibration, it cycles from 9 to 1) Switches between gross wt. / net wt. on the main display 2) When setting the parameter or calibration, it shifts the flashing character to the left 1) Manually output serial / parallel data 2) When setting the parameter or calibration, it shifts the flashing character to the right 1) Weight accumulation, sub-total function (for OP-5) 2) Sets capacity parameter 1) Weight accumulation, grand-total function (for OP-5) 2) Capacity calibration Confirmation key 7

10 4 CAPACITY PARAMETER & CALIBRATION SWITCH Loosen the black plastic screw and open the square cap on the front panel. Slide the switch to the left is ON Slide the switch to the right is OFF 3-2 REAR PANEL DATA IN / OUT 4 CONTROL IN / OUTPUT INPUT OUTPUT 2 1 C2 C LOAD CELL! WARNING Isolating the ac power before opening the covers. FUSE/.5A AC 1V~24V 3 1. AC power in terminal 2. Fuse 25V /.5A 3. Load cell connector 4. Optional interface location (if fitted) 5. Control I/O Interface location

11 CHAPTER 4 INSTALLATION 4-1 LOAD CELL Load cell cable Load cell EXC+ SEN+ SIG+ SIG- EXC- SEN- Shield Four-wire (five-wire) load cell Pin 1 & 2 short, connected to EXC+ Pin 3 & 4 short, connected to EXC- Pin 5 connected to SIG+ Pin 6 connected to SIG- Pin 7 connected to the Shield Six-wire (seven-wire) load cell Pin 1 connected to EXC+ Pin 2 connected to SEN+ Pin 3 connected to EXC- Pin 4 connected to SEN- Pin 5 connected to SIG+ Pin 6 connected to SIG- Pin 7 connected to the Shield 4-2 INDICATOR INSTALLATION AND DIMENSIONS 2 The indicator can be installed in a control panel as detailed below 9

12 CONTROL IN / OUTPUT INPUT OUT PUT AC 1V~24V! WARNING FUSE/.5A Isolating the ac power before opening the covers. LOAD CELL INDICATOR DIMENSIONS (measurement unit: mm) DATA IN / OUT C2 C1 3 1 R acer Plus POWER ZE RO MOTION GROSS NET TARE E NTE RED 1

13 CHAPTER 5 CAPACITY CALIBRATION 5-1 PARAMETER SETTING Switch the capacity calibration switch to ON and the display shows. Press the key and the display shows. then enter the setting mode. Fn Refer to 3-1 Front Panel for the key functions to set the relative parameters Flow Diagram. 1. Decimal Point.. Setup completed 2. Max. Capacity Setup completed 3. Min. Division. Setup completed Zero Tracking... Setup completed Unstable Detection. Setup completed. Using and keys to choose the desired settings Shift the flashing digit one space to left Shift the flashing digit one space to right Save the settings Exit the settings Switch the calibration switch to OFF 11

14 5-1-2 Description 1) Decimal Point Setting the weight decimal point position, with the following options:,.,.,.,.. 2) Max. Capacity Depending on the decimal point position, the max capacity can be set from to ) Min. Division Depending on the decimal point position and the max capacity, the min. division could be set as 1, 2, 5, 1, 2, 5. 4) Zero Tracking Display Division / Time... 1 D / 1 sec... 2 D / 1 sec... 3 D / 1 sec... 4 D / 1 sec... 1 D / 2 sec... 2 D / 2 sec... 3 D / 2 sec... 4 D / 2 sec.. No zero tracking 12

15 5) Unstable Detection Display Division / Time. 1 d / sec. 2 d / sec. 3 d / sec. 4 d / sec. 5 d / sec. No detection 13

16 5-2 CALIBRATION SETTING Please allow the indicator to warm up at least 15 to 3 minutes before calibration. Switch the capacity calibration switch to ON and the display shows. Press the CAL key and the display shows. then enter the setting mode Calibration Procedure Zero Calibration Zero Calibration Completed Weight Calibration Place calibrated weight Confirmation completed Switch the calibration switch to OFF Increase the number of the flashing digit Decrease the number of the flashing digit Shift the flashing digit one space to left Shift the flashing digit one space to right Save the settings Zero Calibration Exit the settings a) Make sure that there are no objects on the weighing platform and press the key, after the indicator has stabilized the display will show.. The calibration is completed after about 5 seconds. b) To skip the Zero calibration procedure, press the key Weight Calibration a) Place an accurate weight onto the platform; use the front panel keys to key in the weight value. Press the key, after the indicator is stabilized the display will show.. The calibration is completed after about 5 seconds. b) To skip the weight calibration, press the. 14

17 5-2-4 Linearity Calibration Before linearity calibration, make sure Zero calibration and Weight Calibration are properly performed. Set the calibration switch to ON position. Press CAL key Choose Press key Five point linearity calibration. Choosing from 1P ~ 5P by pressing key. No linearity calibration value at this point linearity calibration value present at this point Press to next step Press key to previous step The weight value is displayed. Press to next step Press key to previous step Enter the correct weight value Press to next step The calibrated weight value is displayed when the signal is stable Press to next step Increase the number of the flashing digit Decrease the number of the flashing digit Shift the flashing digit one space to left Shift the flashing digit one space to right Save the settings Exit the settings After finishing the first linearity calibration, choose to continue or exit the linearity mode by pressing. Refer to 5-4 Error Messages when any error message appears during the procedure. 15

18 Recall Linearity correction point Set the calibration switch to ON position. Press CAL Choose Press key key Five point linearity calibration. Choosing from 1P ~ 5P by pressing key. No linearity calibration value at this point Linearity calibration value at this point Press key The weight value is displayed. Press key After finishing the first linearity calibration, choose to continue or exit the linearity mode by pressing. Increase the number of the flashing digit Decrease the number of the flashing digit Shift the flashing digit one space to left Shift the flashing digit one space to right Save the settings Exit the settings 16

19 Clear a linearity correction point Set the calibration switch to ON position. Press C A L key Choose Press key Five point linearity calibration. Choosing from 1P ~ 5P by pressing key. No linearity calibration value at this point Linearity calibration value at this point Press key The weight value is displayed. Press key After finishing the first linearity calibration, users can choose to continue or exit the linearity mode by pressing. Increase the number of the flashing digit Decrease the number of the flashing digit Shift the flashing digit one space to left Shift the flashing digit one space to right Save the settings Exit the settings 17

20 5-3 PASSWORD SETTING Set the calibration switch to ON position. Press Press Press key key key Set the new password * Enter to skip password setting. Confirm the password (re-enter the password again) Increase the number of the flashing digit Decrease the number of the flashing digit Shift the flashing digit one space to left Shift the flashing digit one space to right Save the settings Exit the settings 4 Once the password is set, whenever users access to the calibration mode or the other function settings, the display shows and users need to enter the password. After I sec., 4 If the password is incorrect,. is displayed. 18

21 5-4 ERROR MESSAGES (1) The output voltage of load cell is < -.1mV/V or > 4mV/V (2) The weight setting value is not over the setting value of prior section. (3) The actual weight value is not over the value of prior section. (4) The setting value is. (5) Calibration resolution is less.12μv / d. (6). Incorrect password 19

22 CHAPTER 6 ANIMAL SCALE FUNCTION SETTING 2 FUNC. 8 = 1 (Animal scale function is active) is displayed, when there is no object on the weight panel: The weight of live stocks is measured and showed in the display, (2 kg in this example):. The weight value will be held until removing all the objects on the weight panel. When the weight value is below zero band and display shows, the scale is ready for another weighing operation. 2

23 CHAPTER 7 INTERFACES 7-1 OP-1 RS-422 & RS-485 INTERFACE 2 OP-1 RS-422 / RS-485 With this interface up to 1 indicators can be connected together and data transferred to a host controller. FUNC. 7 should be set to 1 2 Connector pin assignment REAR PANEL 5 DATA OUT Pin number Function 1 SDA 2 SDB 3 RDA 4 RDB 5 TRM 6 7 SG 8 9 RDB 21

24 2 Connection method RS-422 SDA SDB RDA RDB SG HOST COMPUTER SDA(1) SDB(2) RDA(3) RDB(4) SG(6.7.8) TRM(5) RDB'(9) EX-21#1 FUNC67=1 SDA(1) SDB(2) RDA(3) RDB(4) SG(6.7.8) TRM(5) RDB'(9) EX-21#2 FUNC67=2 RS-485 DA DB SG HOST COMPUTER SDA(1) SDB(2) RDA(3) RDB(4) SG(6.7.8) TRM(5) RDB'(9) EX-21#1 FUNC67=1 SDA(1) SDB(2) RDA(3) RDB(4) SG(6.7.8) TRM(5) RDB'(9) EX-21#2 FUNC67=2 SDA(1) SDB(2) RDA(3) RDB(4) SG(6.7.8) TRM(5) RDB'(9) EX-21#1 FUNC67=1 SDA(1) SDB(2) RDA(3) RDB(4) SG(6.7.8) TRM(5) RDB'(9) EX-21#1 FUNC67=1 4 Remark: When connecting the last EX-21 indicator, the fifth pin (TRM) and the ninth pin (RDB ) should be connected together, excluding the following two conditions:- The host computer has a built-in terminator. The host computer does not have signal ground (SG). 22

25 2 Refer to Chapter 9 Function Table to set FUNC. 6 ~ FUNC Transmit format S T, G S, g CR LF Header 1 Header 2 Weight Data ( 8 digits ) Units Terminators Header 1 ST : Stable / US : Unstable / OL : Over Load Header 2 GS : Gross weight / NT : Net weight / TR : Tare Weight Data ( 8 digits ) The first digit is the + / - symbol for weight value. The next seven digits include decimal point and weight value. When the weight is over loaded ( Header 1 : OL ), all digits will be transmitted blank (sp) except the + / - signal and the decimal point. Units Kg, g, t, lb or blank Terminators CR, LF is the data finish code. 2 Command mode COMMAND READ, RW ZERO, MZ TARE, MT NTGS MG MN CT FUNCTION Reads weight Back to zero Tare Switches gross / net weight Displays gross weight Displays net weight Clears tare The command string must be terminated with CR ( DH ), LF ( AH ). If a wrong command is received, the indicator will reply E + error command. If the command mode has been selected with address, (FUNC. 61 = 4) then every command must be preceded with an indicator address in the address Example: To read the weight value form indicator addressed as 1 ( 1 selected in FUNC. 67) The complete command 23

26 7-2 OP-2 PARALLEL BCD OUTPUT 2 Pin assignment REAR PENAL 25 DATA OUT 1 BCD parallel output interface uses Centronic 5 PIN connector 5 26 Pin number Function Pin number Function 1 SG 26 SG Gross/-NET ¹ ¹ ¹ 33 Stable 9 8 1¹ ² ² ² ² ³ ³ ³ ³ 42 POSITIVE DP1¹ DP1² DP1³ DP OVER Data ready Hold input 24

27 2 Refer to Chapter 9 Function Table to set FUNC. 8 ~ FUNC Output equivalent circuit TTL Output Open Collector Output +3V(max.) Signal out SG 3mA(max.) Signal out SG 2 Hold Input Hold Input +5V Signal in SG 2 Output / Input signal description A total of 33 bit outputs are provided. To set the output logic level, refer to Chapter 9 FUNC 82 and FUNC 83. If Open Collector output is selected, an external resistor is required to limit the current in the interface. The voltage should not exceed 3Vdc and current should be less than 3mA. Hold input is the only one input signal. To activate the Hold input, just connect the Hold input to SG signal. When Hold is working, all BCD outputs will be held and cannot be altered. Data output Data ready Hold 2ms 5ms 25

28 7-3 OP-3 ANALOGUE CURRENT / VOLTAGE OUTPUT INTERFACE 2 Connections DATA OUT A- A+ Interface specification Analogue current output : ~ 2 ma Load resister : ~ 55 Ω Resolution : 12 bit 2 Refer to Chapter 9 Functions Table to set FUNC 85 ~ FUNC 89 2 Voltage output J1 short if the voltage output is ~ 1V. J1 open if the current output is 4 ~ 2mA. DATA OUT J1 26

29 7-4 OP-5 PARALLEL PRINTER OUTPUT & RS-232 & CURRENT LOOP 2 Pin assignment Pin number Function Pin number Function 1 STROBE 14 NC 2 D 15 ERROR 3 D1 16 INIT 4 D2 17 NC 5 D3 18 SG 6 D4 19 SG 7 D5 2 SG 8 D6 21 SG 9 D7 22 SG 1 ACK 23 SG 11 BUSY 24 SG 12 NC 25 SG 13 NC 2 Refer to Chapter 9 Functions Table to set FUNC 9 ~ FUNC 99 2 RS-232 pin position Pin number Function Pin number Function 1 TXD 3 C. LOOP1 2 SG 4 C. LOOP2 2Refer to Chapter 9 Functions Table to set FUNC. 6, 62, 63, 64 27

30 2 Print format Format 1 ( FUNC. 9= ) FUNC. 95 Print SN value FUNC. 95 = No SN value DATE : 24/8/3 DATE : 24/8/3 TIME : 12:13:36 TIME : 12:13:36 SN. : 1 GROSS : 11.5 kg GROSS : 11.5 kg TARE : 1.5 kg TARE : 1.5 kg NET : 1. kg NET : 1. kg Format 2 ( FUNC. 9=1 ) Material : DATE : 24/8/3 SN. TIME NET(kg) 1 12:14: :14: SUB TOTAL DATE : 24/8/3 COUNT : 2 NET : 18. kg 3 12:14:57 8. SUB TOTAL DATE : 24/8/3 COUNT : 1 NET : 8. kg GRAND TOTAL DATE : 24/8/3 COUNT : 3 NET : 26. kg Format 3 ( FUNC. 9=2 ) SN. DATE TIME GROSS (kg) TARE (kg) NET (kg) 1 24/8/3 12:16: /8/3 12:16: SUB TOTAL /8/3 12:17: /8/3 12:17: GRAND TOTAL 2. 28

31 Format 4 ( FUNC. 9=3 ) EZ-2 print format FUNC. 95 Print SN value FUNC. 95 = No SN value 24/11/26 8:53:5 24/11/26 8:53:5 SN. : 1 GROSS : 5. GROSS : 5. TARE :. TARE :. NET : 5. NET : mm Label Width 2 mm Label Space 24/11/26 8:52:5 24/11/26 8:52:5 SN. : 1 GROSS : 5. GROSS : 5. TARE :. TARE :. NET : 5. NET : mm Label Width 29

32 7-5 OP-6 RS-232 & CURRENT LOOP 2 RS-232 / Current Loop RS-232C is a bi-directional output/input; Current Loop is one-way output only, and the output data format is the same as RS-232. CONNECTION FG RxD TxD SG AC - AC C.LOOP C.LOOP

33 7-6 OP-7 RS-232, CURRENT LOOP & DATA CLOCK OUTPUT 2 RS-232 / Current Loop RS-232C is a bi-directional output/input; Current Loop is one-way output only, and the output data format is the same as RS-232. CONNECTION FG RxD TxD SG AC - AC C.LOOP C.LOOP Data Clock serial output FUNC. 7 should be Inner Connection Pin Position Function 1 + 5V 2 DATA 3 CLK 4 GND DATA/CLK GND 31

34 7-7 OP-8 CONTROL I /O (2I /4O) INTERFACE 2 External input and relay output CONTROL IN / OUTPUT INPUT OUTPUT 2 1 C2 C Output Pin Function 1 : Zero Band 2 : Hi 3 : Ok 4 : Lo Input / output connectors on the rear panel 12V OUTPUT 1~4 1A 3VDC/25VAC C1 The output circuit of Relay +12V INPUT 1~2 C2 The input circuit 32

35 2 HI, OK, LO Output Procedure Start Check Weighing Mode Selected ( FUNC.53 setting) Comparison occurs at any time Y NET < LO FUNC.53 = FUNC.53 = 1 FUNC.53 = 2 Comparison occurs ( One time weighing after inputting comparison occurs after Auto external judgment receiving the external comparison signal judgment signal, including the lead time ) Y LO / UNDER Output Judgment Signal Input N Y NET > Auto transmit range (FUN1 setting) ( One time weighing comparison occurs when the weight of the object is over Zero and stable ) N N Y Y LO NET < HIGH Y OK / FINAL Output Lead time count down of inputting judgment signal (FUNC.55 setting) The weight value is stable N N NET HIGH Y HI / OVER Output Input judgment signal N Y NET < LO Y LO / UNDER Output Y N NET < LO Y LO / UNDER Output LO NET < HIGH Y OK / FINAL Output N N LO NET < HIGH Y OK / FINAL Output NET HIGH Y HI / OVER Output N NET HIGH Y HI / OVER Output 33

36 2 The Flow Chart of HI, OK, LO Setting Press and hold, followed by pressing CAL, to enter the check weighing mode. Press key Press or key to select the high value ( ), low value ( ), and zero ( ). Key in the High Limit Value by using the keys described at the right hand side. Press key to complete the setting and go to the next step Increase the number of the flashing digit Decrease the number of the flashing digit Shift the flashing digit one space to left Shift the flashing digit one space to right Save the settings Exit the settings 34

37 Hi Hi Lo Lo Zero band Zero band Zero band Zero band Lo Lo Hi Hi Func54= Func54= General Comparison General comparison Zero _ band Zero _ band Lo Lo OK Hi ok high Func54=1 Func54=1 Absolute Value Comparison Absolute value comparison Zero band Zero band Lo Lo ok OK high Hi 35

38 CHAPTER 8 MAINTENANCE 8-1 RESET ALL PARAMETERS BACK TO DEFAULT (1) Switch the capacity calibration switch to ON, press and hold keys together when the indicator is in the self-testing sequence. (2) The display shows.. (3) Press and hold the key until the display shows. Switch the calibration switch to OFF. Fn 8-2 RESET GENERAL FUNCTION PARAMETERS BACK TO DEFAULT (1) When the indicator reset back to zero, press and hold Fn keys. The indicator is in the self-testing sequence. (2) The display shows.. (3) Press and hold the key until the indicator resets. 8-3 SELF-DIAGNOSIS MODE (1) When the indicator reset back to zero, press and hold keys. The indicator is in the self-testing sequence. (2) When the display shows, it means the indicator is already in the Self-diagnosis mode. (3) Press and keys to select a diagnosis item. Press the key to enter the selected item for diagnosis and press to exit. 36

39 No. Display Diagnosis Item 1 7 digits display and LED status lights 2 Keyboard and calibration ON / OFF switch 3 OP-6 RS-232 serial output / input interface 4 OP-2 BCD parallel output interface 5 OP-3 Analogue current output interface 6 OP-5 Parallel printer interface 7 EEPROM memory on main board 8 OP-8 Control I/O interface Digit Display and LED Status Light Diagnosis 7 digit display shows ~,. And at the same time, the LED status lights turn on and off in order Keyboard and Calibration ON / OFF Switch Diagnosis Switch the calibration switch to ON, or press any keys and the corresponding digit goes from on the display RS-232 Serial Output / Input Interface Diagnosis ( OP-6 ) (1) Short circuit the 2 nd pin and 3 rd pin of the SER. OUT. D-SUB 25 pin connector. = Working properly = Malfunction (2) If connecting to a computer (The communication protocol has to be compatible), if ~ can be read, it indicates that the RS-232 is in working order BCD Parallel Output Interface Diagnosis ( OP-2 ) (1) The decimal point flashes during the diagnosis. (2) The program sends out OFF ON OFF signals from each of BCD output bit. (3) If is displayed, this indicates that no BCD interface is installed. 37

40 8-3-5 Analogue Current Output Interface Diagnosis ( OP-3 ) (1) Use and keys to select output current. (a) : 4mA (b) (c) : 12mA : 2mA (2) If is displayed, this indicates that an interface has not been installed Parallel Printer Interface Diagnosis ( OP-5 ) (1) Connect the interface to the printer. (2) Press the key and the printer will print date, time and ASCII code as 3H ~ 7AH characters or figures. (3) If is displayed, this indicates that the printer or the interface is not working properly. (4) If is displayed, the interface is not connected to the indicator Main Board EEPROM Memory Diagnosis = Working properly = Malfunction OP-8 Control I /O (2I /4O) Diagnosis _ Activate the input signal by choosing (ON) or (OFF) Press parameters ( ~ ) key to alternately select one of 38

41 CHAPTER 9 FUNCTION TABLE 9-1 GENERAL FUNCTION FUNC. NO. FUNCTION SET VALUE DEFAULT FUNC. Tare and Zero function ON when the weight is unstable 1 OFF FUNC. 1 FUNC. 2 Tare function with negative gross weight Key function ON 1 OFF corresponding ON keys from left to right are OFF FUNC. 3 FUNC. 4 FUNC. 5 FUNC. 6 Auto Zero function OFF after power on 1 ON Zero range Weighing Filter A/D sampling frequency D 9D 5 When the weight is in this range ±(Set value Min. division) it displays The larger the value the greater the amount of filtering. When set to, the filter will adjust automatically. Unlimited 1 2 times/sec 2 1 times/sec 3 5 times/sec Unlimited 1 2 times/sec FUNC. 7 Display update rate 2 1 times/sec 3 5 times/sec 4 1 times/2sec FUNC. 8 Animal scale OFF 1 ON 39

42 9-2 OP-1, OP-6, OP-7 INTERFACE FUNCTION FUNC. NO. FUNC. 6 FUNC. 61 FUNC. 62 FUNC. 63 FUNC. 64 FUNC. 65 FUNC. 66 FUNC. 67 FUNC. 68 FUNC. 69 FUNC. 7 FUNCTION SET VALUE PARAMETER DESCRIPTION As displayed 1 Gross Data type 2 Net 3 Tare Stream transmit 1 Auto-transmit 2 Press t key to transmit Transmit mode Command mode 3 (without address) Command mode 4 (with address) BAUD rate No parity bit, N, 8, 1 Parity bit 8 data bit, 1 stop bit Odd parity bit, Data bit 1 O, 7, 1 7 data bit, 1 stop bit Stop bit Even parity bit, 2 E, 7, 1 7 data bit, 1 stop bit None 1 kg Units 2 g 3 t 4 lb Unstable or Continuous output over the max. capacity 1 Stop output Positive (more than + 5D) Auto-transmit conditions Command address Output format Transmit frequency Output type 1 99 Positive / negative (more than + 5D, less than - 5D) When the FUNC. 61 is set in 4, it will use this address Standard Format 1 UMC 6 W/o limit 1 1 Time/ Sec. 2 2 Times/ Sec. 3 5 Times/ Sec. 4 1 Times/ Sec. 5 2 Times/ Sec. Close RS422/485 1 Start RS422/485 DEFAULT

43 9-3 OP-2 BCD OUTPUT INTERFACE FUNCTION FUNC. NO. FUNCTION SET VALUE PARAMETER DESCRIPTION DEFAULT As displayed FUNC. 8 Data type 1 Gross 2 Net Stream transmit 1 Auto-transmit FUNC. 81 Transmit mode 2 Press the key to transmit FUNC. 82 Output data logic Positive logic 1 Negative logic FUNC. 83 Signal logic Positive logic 1 Negative logic 9-4 OP-3 ANALOGUE OUTPUT INTERFACE FUNCTION FUNC. NO. FUNC. 85 FUNC. 86 FUNC. 87 FUNC. 88 FUNC. 89 FUNCTION Data type Low point of weight value Low point of output current value High point Weight value High point Output current value SET VALUE PARAMETER DESCRIPTION DEFAULT As displayed 1 Gross 2 Net ma 2. ma ma 2. ma When the weight value reaches the value set in Func. 86, the current output is the value set in Func. 87 When the weight value reaches the value set in Func. 88, the current output is the value set in Func ma ma 41

44 9-5 OP-5 PARALLEL PRINTER OUTPUT INTERFACE FUNCTION FUNC. NO. FUNCTION SET VALUE DEFAULT PARAMETER DESCRIPTION FUNC. 9 Data format Select print format FUNC. 91 Transmit mode Press the to transmit 1 Auto / press to transmit FUNC. 92 The size of left hand side margin ~ 8 (characters) FUNC. 92 TIME: 14:2:3 GROSS: 23.5kg FUNC. 93 FUNC. 93 The space between blocks of data ~ 8 ( LF ) TIME: 15:3:2 GROSS: 21.kg 5 FUNC. 94 Material number When printing the material number, it keeps the same value as previously set. FUNC. 95 FUNC. 96 Serial number Units When printing the serial number, it automatically increments. It resets to after restarting the indicator or after printing out the total weight. None 1 kg 2 g 3 t 4 lb 1 1 FUNC. 98 Date setting 2 yr. 299 yr. FUNC. 99 Time setting :: 23:59:59 42

45 9-6 OP-8 CONTROL I /O (2I /4O) INTERFACE FUNCTION FUNC. NO. FUNCTION PARAMETER SET VALUE DESCRIPTION DEFAULT FUNC. 5 Input 1 No capacity 1 1 Zero 2 Tare 3 Clear Tare FUNC. 51 Input 2 4 judgment_comm_flag 2 FUNC. 52 Output logic Positive logic 1111 Negative logic FUNC. 53 Hi,OK,Lo Check weighing mode Comparison occurs at any time 1 Comparison occurs after inputting external judgment signal 2 Auto comparison FUNC. 54 Comparison mode General comparison + 1 Absolute value only comparison +/- FUNC. 55 Lead time setting for activating comparison Lead time setting for inputting external judgment signal.5 43

D-500s Indicator D LED. User Instructions. English Issue September SangR. Page 2. User s manual of Sang D-500s LED

D-500s Indicator D LED. User Instructions. English Issue September SangR. Page 2. User s manual of Sang D-500s LED D-500s Indicator D - 500 LED User Instructions English 8921-004210 Issue September 2010 1 2-2 0 1 0 D 6 0 0 4 6 7 5 Page 2 D-500s Indicator Page 2 Table of Content Section 1: Introduction. 1.1 Introduction

More information

AD-8923-BCD. Remote Controller (BCD) INSTRUCTION MANUAL 1WMPD

AD-8923-BCD. Remote Controller (BCD) INSTRUCTION MANUAL 1WMPD AD-8923-BCD Remote Controller (BCD) INSTRUCTION MANUAL 1WMPD4002137 2010 A&D Company, Limited. All rights reserved. No part of this publication may be reproduced, transmitted, transcribed, or translated

More information

! User Manual Rev. 1

! User Manual Rev. 1 User Manual Rev. 1 Warnings For safety operation of the weighing indicator, please follow the following warning/ safety instructions: Calibration inspection and maintenance of the indicator are prohibited

More information

AD-4532B. Digital Indicator INSTRUCTION MANUAL 1WMPD A

AD-4532B. Digital Indicator INSTRUCTION MANUAL 1WMPD A AD-4532B Digital Indicator INSTRUCTI MANUAL 1WMPD4001683A WARNING DEFINITIS The warnings described in this manual have the following meanings: A potentially hazardous situation which, if not avoided, could

More information

This document hosted by: Extension Load Cell Cable (OP-02)

This document hosted by: Extension Load Cell Cable (OP-02) This document hosted by: www.oldwillknottscales.com 17.1. Extension Load Cell Cable (OP-02) This cable is used for installing the indicator away from the base unit. This extension load cell cable is 5

More information

Trade Approved Version NMI: S520

Trade Approved Version NMI: S520 @Weigh BW/BWS Series Trade Approved Version NMI: S520 Weighing Indicator User s guide UGBW-E1.09 Table of Contents SECTION 1 INTRODUCTION. 1 SECTION 2 SPECIFICATIONS... 2 SECTION 3 INSTALLATION.3 3. 1

More information

Excell Precision Limited All rights reserved Worldwide. The information contained herein is the property of Excell Precision Limited and is

Excell Precision Limited All rights reserved Worldwide. The information contained herein is the property of Excell Precision Limited and is User Manual Wireless Platform TM Excell Precision Limited 2017. All rights reserved Worldwide. The information contained herein is the property of Excell Precision Limited and is supplied without liability

More information

Calibration & Connectivity

Calibration & Connectivity Calibration & Connectivity TS-700 Series Digital Indicators This document supplements the User s Guide TS-700 MS TS-700 SS TS-700 WB Full Function/Advanced Function Digital Indicator www.trinerscale.com

More information

Multi-Function Smart Indicator User Manual

Multi-Function Smart Indicator User Manual Multi-Function Smart Indicator User Manual EC30006 Content 1 Notice... 2 2 Specification... 2 3 Main parameter... 3 4 How to fix... 3 5 Port... 4 6 On/Off... 4 7 Charging... 4 8 Display... 5 9 Screen keypad...

More information

This document hosted by: 10. OPTIONS

This document hosted by:  10. OPTIONS This document hosted by: www.oldwillknottscales.com 10. OPTIONS The following options are available for the FG series: OP-23 (FG-23) RS-232C serial interface OP-24 (FG-24) RS-232C serial interface and

More information

KW serial. User s guide. Bench Scales UGKW-E0302

KW serial. User s guide. Bench Scales UGKW-E0302 KW serial Bench Scales User s guide UGKW-E0302 KW serial bench scale user s manual Table of Contents SECTION 1 INTRODUCTION 1 SECTION 2 SPECIFICATIONS.. 2 SECTION 3 INSTALLATION.3 SECTION 4 KEY DESCRIPTIONS

More information

Cảm ơn các bạn đã tham khảo tài liệu cân điện tử từ CÂN ĐIỆN TỬ GIA PHÁT!

Cảm ơn các bạn đã tham khảo tài liệu cân điện tử từ CÂN ĐIỆN TỬ GIA PHÁT! Đ/c1: 534 Điện Biên Phủ, Phường 21, Quận Bình Thạnh, Tp Hồ Chí Minh Đ/c2: 42 Hùng Vương, Phường Xuân Bình, Thị xã Long Khánh, Tỉnh Đồng Nai Website: www.cangiaphat.com Email: giaphat.scale@gmail.com Zalo,

More information

1. Introduction Page 2. Specifications Page Installation Page Key Functions Page Operations Page 6. Check Weighing Page 6

1. Introduction Page 2. Specifications Page Installation Page Key Functions Page Operations Page 6. Check Weighing Page 6 Contents: 1. Introduction Page 2 Specifications Page 2 2. Installation Page 3 3. Key Functions Page 4 4. Operations Page 6 Check Weighing Page 6 Accumulation Page 7 Parts Counting Page 7 Print (RS232C)

More information

CHAPTER 1. Introduction Introduction 3

CHAPTER 1. Introduction Introduction 3 Technical & User Manual Weight Indicator: SMIT-3015 Manufactured By: Samyak Instrumentation Pvt.Ltd. F-4, Memnagar Complex, Opp.Petrol Pump, Memnagar Village, Ahmedabad, India-380052. Phone: +91-79-27495500/5600,

More information

CAUTIONS... 4 INTRODUCTION...

CAUTIONS... 4 INTRODUCTION... CONTENTS CAUTIONS... 4 INTRODUCTION... 6 FEATURES & MAIN FUNCTIONS... 6 SPECCIFICATION... 7 PART NAME & KEY FUNCTION... 8 SYSTEM MODE...11 GENERAL FUNCTION & DESCRIPTION... 16 CONVERSION MODE... 18 PRINT

More information

Technical Parameter... 4 Installation and Connection... 5

Technical Parameter... 4 Installation and Connection... 5 2 CONTENTS Technical Parameter... 4 Installation and Connection... 5 1. Indicator Diagram... 5 2. Loadcell Connection... 6 3. Serial Communication interface and Scoreboard... 7 Operation Instruction...

More information

PS-IN202 Weighing Indicator User Manual

PS-IN202 Weighing Indicator User Manual PS-IN202 Weighing Indicator User Manual Version 2015.05 Contents FRONT AND REAR VIEW OF THE INDICATOR CHAPTER 1 CONNECTIONS 1.1 WHAT'S IN THE BOX 1.2 CONNECTING TO THE WEIGH PLATFORM 1.3 CONNECTION TO

More information

UWE-1707 SERIES CONTENTS OPERATION MANUAL ELECTRONIC WEIGHING INDICATOR 1. SPECIFICATIONS 2. INSTALLATION

UWE-1707 SERIES CONTENTS OPERATION MANUAL ELECTRONIC WEIGHING INDICATOR 1. SPECIFICATIONS 2. INSTALLATION UWE-1707 SERIES CONTENTS ELECTRONIC WEIGHING INDICATOR OPERATION MANUAL 1. SPECIFICATIONS PLEASE READ THIS MANUAL VERY CAREFULLY BEFORE ATTEMPT TO OPERATE THE SCALE 2. INSTALLATION 3. ROUTINE OPERATION

More information

AD-4401 WEIGHING INDICATOR A-IE

AD-4401 WEIGHING INDICATOR A-IE AD-440 WEIGHING INDICATOR 386-2A-IE 998 A&D Company Ltd. All rights reserved. No part of this publication may be reproduced, transmitted, transcribed, or translated into any language in any form by any

More information

Table of Contents. 3-1 Specifications & Features Front Panel Display Keyboard. 3-3 Rear Panel. 3-4 Power Supply. 4.

Table of Contents. 3-1 Specifications & Features Front Panel Display Keyboard. 3-3 Rear Panel. 3-4 Power Supply. 4. Table of Contents 1. Introduction 1 2. Precaution... 1 3. Product Introduction 3-1 Specifications & Features... 3-2 Front Panel 3-2-1 Display 3-2-2 Keyboard. 3-3 Rear Panel. 3-4 Power Supply. 4. Installation

More information

TABLE OF CONTENTS. Communication Functions

TABLE OF CONTENTS. Communication Functions TABLE OF CONTENTS Chapter 1: Chapter 2: Chapter 3: Chapter 4: General Features....................................................... 1-1 Functions......................................................

More information

Table of Contents 1. Introduction Features & Main function Technical Specification Measure of Appearance...

Table of Contents 1. Introduction Features & Main function Technical Specification Measure of Appearance... 2 Table of Contents 1. Introduction... 4 2. Features & Main function... 6 3. Technical Specification... 7 4. Measure of Appearance... 9 5. Front Panel... 10 6. Rear Panel... 14 7. Installation & Connection...

More information

Vibration-Resistant Weighing Indicator

Vibration-Resistant Weighing Indicator Vibration-Resistant Weighing Indicator Powerful vibration-cancelling function (High Performance Digital Filter) High speed sampling (100 times/second)/high accuracy Circuits equipped with powerful noise

More information

M260 Load Cell Amplifiers

M260 Load Cell Amplifiers E L 4 - + 2-3 1-2 M260 Load Cell Amplifiers Description. This fast start guide shows basic installation, setup, and calibration for most applications. For more specific information contact Minsterport.

More information

AD Remote Controller INSTRUCTION MANUAL WM+PD A

AD Remote Controller INSTRUCTION MANUAL WM+PD A AD-8922 Remote Controller INSTRUCTION MANUAL WM+PD4000929A 2005 A&D Company Ltd. All rights reserved. No part of this publication may be reproduced, transmitted, transcribed, or translated into any language

More information

GS100P. Weighing Controller. Contents. Order Codes

GS100P. Weighing Controller. Contents. Order Codes GS100P Weighing Controller 1 This intelligent weighing controller comes precalibrated to suit either a 4-wire or a 6-wire strain gauge input, and has a number of advanced functions designed specifically

More information

WUNDER SA.BI.SRL EN USER MANUAL. MULTIFUNCTIONS ELECTRONIC SCALE MOD. W100 LED. User Manual

WUNDER SA.BI.SRL EN USER MANUAL.   MULTIFUNCTIONS ELECTRONIC SCALE MOD. W100 LED. User Manual www.wunder.it MULTIFUNCTIONS ELECTRONIC SCALE MOD. W100 LED User Manual Read this manual carefully before using the instrument W100 SCALE W100 INDICATOR INDICE 2. BEFORE USING PAG. 2 3. SPECIFICATIONS

More information

DWP-98 Series. Counting scale. User s Guide PLEASE READ THIS MANUAL VERY CAREFULLY BEFORE ATTEMPT TO OPERATE THE INSTRUMENT

DWP-98 Series. Counting scale. User s Guide PLEASE READ THIS MANUAL VERY CAREFULLY BEFORE ATTEMPT TO OPERATE THE INSTRUMENT c DWP-98 Series Counting scale User s Guide PLEASE READ THIS MANUAL VERY CAREFULLY BEFORE ATTEMPT TO OPERATE THE INSTRUMENT Specifications subject to change without prior notice CONTENTS 1. INSTALLATION

More information

COMPLETE MANUAL. WEIGHING INDICATOR TI-1200 and TI-1200-S TI-1200 with rechargeable battery.

COMPLETE MANUAL. WEIGHING INDICATOR TI-1200 and TI-1200-S TI-1200 with rechargeable battery. COMPLETE MANUAL WEIGHING INDICATOR TI-1200 and TI-1200-S TI-1200 with rechargeable battery. TI-1200-S without rechargeable battery and with a smaller cabinet. Note: When TI-1200 is shipped as a part of

More information

USER INSTRUCTION MANUAL FOR LOADCELL TRANSMITTER MODEL TDC/I/0550 (SOFTWARE: VER2A) INDEX

USER INSTRUCTION MANUAL FOR LOADCELL TRANSMITTER MODEL TDC/I/0550 (SOFTWARE: VER2A) INDEX USER INSTRUCTION MANUAL FOR LOADCELL TRANSMITTER MODEL TDC/I/0550 (SOFTWARE: VER2A) INDEX DOCUMENT NO: TDC 0550 MANUAL - 2 1.0) INTRODUCTION. PAGE 2 1.1) ABOUT THIS MANUAL. PAGE 2 1.2) INTRODUCTION. PAGE

More information

DCS Series. Digital Counting Scale. Setup Manual

DCS Series. Digital Counting Scale. Setup Manual DCS Series Digital Counting Scale Setup Manual Revision 1.1 February 12, 1997 1996-1997 Transcell Technology, Inc. Contents subject to change without notice. Transcell Technology, Inc. 975 Deerfield Parkway

More information

Pennsylvania Scale Company Model 400B Battery Powered Digital Indicator Operation & Calibration Manual

Pennsylvania Scale Company Model 400B Battery Powered Digital Indicator Operation & Calibration Manual Pennsylvania Scale Company Model 400B Battery Powered Digital Indicator Operation & Calibration Manual Pennsylvania Scale Company 1042 New Holland Avenue Lancaster PA 17601 For online interactive tech

More information

MI101 / MI102 / MI102S INDICATOR

MI101 / MI102 / MI102S INDICATOR MI101 / MI102 / MI102S INDICATOR USER GUIDE Preface Thank you for purchasing the MI series indicator from Millennium Mechatronics Limited, New Zealand. The MI101/MI102 Indicator is an accurate, fast and

More information

Digital Bench Scale. Revision 1.2 August 24, Contents subject to change without notice.

Digital Bench Scale. Revision 1.2 August 24, Contents subject to change without notice. Digital Bench Scale Revision 1. August 4, 000 Contents subject to change without notice. Salter Brecknell Weighing Products 1000 Armstrong Drive Fairmont, MN 56031 Tel (800) 637-059 Tel (507) 38-870 Fax

More information

Warning. Warning. Warning. Pay Attention to Static Electricity. Ask professional personnel to debug, detect. and repair controller.

Warning. Warning. Warning. Pay Attention to Static Electricity. Ask professional personnel to debug, detect. and repair controller. Warning Ask professional personnel to debug, detect and repair controller. Warning Warning Please keep good grounding of controller. In electrical connection of controller, please cut off the power supply

More information

AD-8923-CC. Remote Controller (CC-Link) INSTRUCTION MANUAL 1WMPD B

AD-8923-CC. Remote Controller (CC-Link) INSTRUCTION MANUAL 1WMPD B AD-8923-CC Remote Controller (CC-Link) INSTRUCTION MANUAL 1WMPD4002124B 2013 A&D Company, Limited. All rights reserved. No part of this publication may be reproduced, transmitted, transcribed, or translated

More information

The IQ240 panel mount load cell indicator is a precision digital indicator for load cell and strain gauge applications.

The IQ240 panel mount load cell indicator is a precision digital indicator for load cell and strain gauge applications. IQ240 Panel Mount Load Cell Indicator Data sheet English 1.01 Introduction The IQ240 panel mount load cell indicator is a precision digital indicator for load cell and strain gauge applications. The high

More information

Weighing Indicator USER S GUIDE. globalindustrial.com. globalindustrial.com. 11 Harbor Park Drive Port Washington, NY 11050

Weighing Indicator USER S GUIDE. globalindustrial.com. globalindustrial.com. 11 Harbor Park Drive Port Washington, NY 11050 Weighing Indicator USER S GUIDE 0713 11 Harbor Park Drive Port Washington, NY 11050 Table of Contents I Main Specifications.............................3 II Display and Keyboard..........................4

More information

GS125. Contents. Features. Optional. Strain Gauge Input LED Large Display

GS125. Contents. Features. Optional. Strain Gauge Input LED Large Display 1 GS125 Strain Gauge Input LED Large Display This high intensity LED display offers a flexible solution for a variety of highspeed, high accuracy weighing, batching and level measurement operations. Features

More information

USER S GUIDE. Weighing Indicator. globalindustrial.com. Use of RS232 Port Using Windows for the Printer Driver, Adjust Computer Settings as Follows:

USER S GUIDE. Weighing Indicator. globalindustrial.com. Use of RS232 Port Using Windows for the Printer Driver, Adjust Computer Settings as Follows: Use of RS232 Port Using Windows for the Printer Driver, Adjust Computer Settings as Follows: Click On Start Pick Program Weighing Indicator USER S GUIDE Pick Accessories Pick Communications Pick Hyper

More information

PCE Americas Inc. PCE Instruments UK Ltd. 711 Commerce Way Units 12/13, Southpoint Business Park Suite 8 Ensign Way Jupiter, FL 33458 Hampshire / Southampton USA United Kingdom, SO31 4RF Phone: 561-320-9162

More information

Optima OP-900-LD Score Board Indicator (with Remote Control) User Manual

Optima OP-900-LD Score Board Indicator (with Remote Control) User Manual Score Board Indicator (with Remote Control) User Manual Warnings For safety operation of the weighing indicator, please follow the following warning/ safety instructions: Calibration inspection and maintenance

More information

Please keep the following using conditions certainly

Please keep the following using conditions certainly 1 2 Thank you very much for your purchasing BGSHIN Digital Weighing Indicator of BS-7300. This Instruction Manual will lead you to use BS-7300 with top reliability, High speed, high accuracy. BS-7300 is

More information

The IQ300 wall mount load cell indicator is a precision digital indicator for load cell and strain gauge applications.

The IQ300 wall mount load cell indicator is a precision digital indicator for load cell and strain gauge applications. IQ300 Wall Mount Load Cell Indicator Data sheet English 1.01 Introduction The IQ300 wall mount load cell indicator is a precision digital indicator for load cell and strain gauge applications. The high

More information

NTS-4840 Instruction Manual

NTS-4840 Instruction Manual Digital Indicator NTS-4840 Instruction Manual - 4840 DIGITAL INDICATOR ZERO NIPPON TOKUSYU SOKKI CO.,LTD NTS NIPPON TOKUSHU SOKKI Co., LTD. F-600967 1 Introduction Thank you very much for purchasing our

More information

APEX Junior Cased Weighing Indicator/Controller

APEX Junior Cased Weighing Indicator/Controller APEX Junior Cased Weighing Indicator/Controller Non-Trade User Manual www.pcm-uk.com APPROVED DISTRIBUTORS OF: Electronic Weighing Services 1 Index Section 1: Setting Up (Terminations and time/date routines)

More information

SINGLE-CHANNEL PROCESS CONTROLLERS & TEMP. DISPLAYS D3820/D3830 Series

SINGLE-CHANNEL PROCESS CONTROLLERS & TEMP. DISPLAYS D3820/D3830 Series The Digitec Series D3800 Panel Meters offer many features and performance capabilities to suit a wide range of industrial applications. The D3820 and D3830 are available in the ranges of 4-20mA, 0-10 VDC,

More information

7561-PSD Manual Portable Battery Powered Indicator

7561-PSD Manual Portable Battery Powered Indicator 7561-PSD Manual Portable Battery Powered Indicator Lebow Products Inc. 1728 Maplelawn Drive P.O. Box 1089 Troy, Michigan 48084-1089 (800) 803-1164 Phone: (248) 643-0220 FAX: (248) 643-0259 Visit our web

More information

OCEAN WATERPROOF WEIGHING SCALE USER MANUAL

OCEAN WATERPROOF WEIGHING SCALE USER MANUAL OCEAN WATERPROOF WEIGHING SCALE USER MANUAL Excell Precision Limited 2006. All rights reserved Worldwide. The information contained herein is the property of Excell Precision Limited and is supplied without

More information

Digital Weighing Indicator SI 4630 (For both External Display and Indicator)

Digital Weighing Indicator SI 4630 (For both External Display and Indicator) (For both External Display and Indicator) Instruction Manual Version 1.03 (SEP. 2010 ) CONTENTS 1. Before Installation - - - - - - - - - - 3 2. Introduction - - - - - - - - - - 4 3. Specification - - -

More information

1. On / Off. 2. Initial reset to zero

1. On / Off. 2. Initial reset to zero EN USER MANUAL 1 Index 1. On / Off... 3 2. Initial reset to zero... 3 3. Keypad operation... 4 3.1. ON / OFF... 4 3.2. MENU... 4 3.3. TARE... 5 3.4. PRINT / SUM... 6 4. Description of LCD display... 8

More information

Rev Carbon Dioxide (CO2) Gas Sensor. TG100 User Manual

Rev Carbon Dioxide (CO2) Gas Sensor. TG100 User Manual Rev. 2.93 TG100 User Manual The TG100 measuring carbon dioxide (chemical formula CO2) is a NDIR (Non-Dispersive Infrared) gas sensor. As it is contactless, it has high accuracy and longer life than sensors

More information

BS-105 Digital Indicator

BS-105 Digital Indicator BS-105 Digital Indicator The Better Way for Weighing & Measurements 1 CONTENTS Introductions.......... 2 The Features of BS-105.. 3 Technical Specification.. Dimensions............. 6 Front Panel............

More information

Optima OP-902 User Manual

Optima OP-902 User Manual Optima OP-902 User Manual Warnings For safety operation of the weighing indicator, please follow the following warning/ safety instructions: Calibration inspection and maintenance of the indicator are

More information

Digital Weight Indicator Setup / Operation Manual

Digital Weight Indicator Setup / Operation Manual Digital Weight Indicator Setup / Operation Manual Load Cell Central follows a policy of continuous improvement and reserves the right to change specifications without notice. 2013 Load Cell Central Toll

More information

805HP. Handheld Digital Weight Indicator Operations Manual (V1612) Anyload Transducer Co. Ltd Website:

805HP. Handheld Digital Weight Indicator Operations Manual (V1612) Anyload Transducer Co. Ltd Website: 805HP Handheld Digital Weight Indicator Operations Manual (V1612) Anyload Transducer Co. Ltd Website: www.anyload.com Email: info@anyload.com TABLE OF CONTENTS 1. Introduction and Product Features 3 2.

More information

TWP series. Weighing Indicator Service Manual

TWP series. Weighing Indicator Service Manual TWP series Weighing Indicator Service Manual CONTENTS 1. SPECIFICATIONS....3 2. INSTALATION AND PRECAUTIONS..4 Load cell connection......4 Power operation..5 Battery operation.5 3. NAME AND FUNCTIONS........6

More information

Digital Bench Scale. Revision 1.2 September 14, 2000 Contents subject to change without notice.

Digital Bench Scale. Revision 1.2 September 14, 2000 Contents subject to change without notice. Digital Bench Scale Revision 1.2 September 14, 2000 Contents subject to change without notice. Salter Brecknell Weighing Products 1000 Armstrong Drive Fairmont, MN 56031 Tel (800) 637-0529 Tel (507) 238-8702

More information

Characteristics and functioning

Characteristics and functioning Characteristics and functioning 1/1 enod4-t Characteristics and functioning 216702-C_NU-eNod4T-ETH-E-0314 2/2 enod4-t Characteristics and functioning 216702-C_NU-eNod4T-ETH-E-0314 1 ENOD4 PRODUCT RANGE...

More information

TRACKER 240 SERIES. Load Cell and Weighing Indicators. A Precision Measurement Instrument with Outstanding Features

TRACKER 240 SERIES. Load Cell and Weighing Indicators. A Precision Measurement Instrument with Outstanding Features TRACKER 240 SERIES Load Cell and Weighing Indicators A Precision Measurement Instrument with Outstanding Features TRACKER 240 SERIES INDICATORS Ratiometric Measurement Tare and Auto Transducer Excitation

More information

805HP. Handheld Digital Weight Indicator Operations Manual (V1612) Anyload Transducer Co. Ltd Website:

805HP. Handheld Digital Weight Indicator Operations Manual (V1612) Anyload Transducer Co. Ltd Website: 805HP Handheld Digital Weight Indicator Operations Manual (V1612) Anyload Transducer Co. Ltd Website: www.anyload.com Email: info@anyload.com TABLE OF CONTENTS 1. Introduction and Product Features 3 2.

More information

Cautions for Your Safety

Cautions for Your Safety . 2 Cautions for Your Safety Please comply with 'Cautions for Your Safety', which will lead you to use the product safely and properly to prevent any dangerous situations. Cautions are divided into 'Warning'

More information

TWP-W. Weighing Indicator Service Manual

TWP-W. Weighing Indicator Service Manual TWP-W Weighing Indicator Service Manual CONTENTS 1. SPECIFICATIONS....3 2. INSTALATION AND PRECAUTIONS..4 Load cell connection......4 Power operation..5 Battery operation.5 3. NAME AND FUNCTIONS........6

More information

Digital Bench Scale. Revision 8.93 August 12, 1993

Digital Bench Scale. Revision 8.93 August 12, 1993 Digital Bench Scale Revision 8.93 August 12, 1993 Salter Brecknell Weighing Products 1000 Armstrong Drive Fairmont, MN 56031 Tel (800) 637-0529 Tel (507) 238-8702 Fax (507) 238-8271 E-mail: sales@salterbrecknell.com

More information

DWP-PC SERIES PRICE COMPUTING SCALE User s Guide

DWP-PC SERIES PRICE COMPUTING SCALE User s Guide DWP-PC SERIES PRICE COMPUTING SCALE User s Guide PLEASE READ THIS MANUAL VERY CAREFULLY BEFORE ATTEMPT TO OPERATE THE INSTRUMENT Specifications subject to change without prior notice CONTENTS 1. INSTALLATION

More information

SCS3MT080, SCS3MT100, SCS3MT120, SHDHS1500 & SPLS1000 User Manual

SCS3MT080, SCS3MT100, SCS3MT120, SHDHS1500 & SPLS1000 User Manual www.scintex.com.au sales@scintex.com.au SCS3MT080, SCS3MT100, SCS3MT120, SHDHS1500 & SPLS1000 User Manual Technical Data Working Temperature:-5 to 35 C Storage Temperature:-25 to 50 C Stainless Steel Casing:

More information

Weighing Indicator Service Manual V1.24X

Weighing Indicator Service Manual V1.24X Weighing Indicator Service Manual V1.24X CONTENTS 1. PRECAUTIONS.3 2. SPECIFICATIONS....4 3. INTRODUCTION....5 4. INSTALLATION..6 Unpacking 6 Installation 6 Load cell connections......7 Connect Adaptor

More information

LCI User Manual mantracourt.com

LCI User Manual mantracourt.com LCI User Manual mantracourt.com LCI Load Cell Junction Box with Fault Monitor Contents Chapter 1 Introduction to the LCI... 2 Chapter 2 Installing the LCI... 3 Chapter 3 Setting up the LCI... 4 Sequence

More information

Characteristics and functioning

Characteristics and functioning Characteristics and functioning 1/27 enod4-c Characteristics and functioning NU-eNod4C-ETH-E-1014_216706-A 1 ENOD4 PRODUCT RANGE... 4 1.1 General presentation... 4 1.2 Versions and options... 4 1.2.1 Versions...

More information

Rev Carbon Dioxide (CO2) Gas Sensor. TG100 User Manual

Rev Carbon Dioxide (CO2) Gas Sensor. TG100 User Manual Rev. 2.5 TG100 User Manual The TG100 measuring carbon dioxide (chemical formula CO2) is a NDIR (Non-Dispersive Infrared) gas sensor. As it is contactless, it has high accuracy and longer life than sensors

More information

SY021 Portable Load/Force Meter User instructions

SY021 Portable Load/Force Meter User instructions SY021 Portable Load/Force Meter User instructions Relates to firmware version 5.2 INTRODUCTION The SY021 is a portable load meter, which can indicate the load present on any attached cell. A dual channel

More information

Gateway 1400 Reference Manual

Gateway 1400 Reference Manual Profibus-DP Gateway 1400 Reference Manual Copyright All Rights Reserved. No part of this document may be copied, reproduced, republished, uploaded, posted, transmitted, distributed, stored in or introduced

More information

IPM650 Intelligent Panel-Mount Display

IPM650 Intelligent Panel-Mount Display Quick Start Guide IPM650 Intelligent Panel-Mount Display Sensor Solutions Source Load Torque Pressure Multi Component Calibration Instruments Software www.futek.com Getting Help TECHNICAL SUPPORT For more

More information

PRODIS. PD-ADC Digital Process Meter for analog Sensors. Digital Process Meters. Datasheet

PRODIS. PD-ADC Digital Process Meter for analog Sensors. Digital Process Meters. Datasheet Digital Process Meters Digital Process Meter for analog Sensors Datasheet Copyright ASM GmbH Am Bleichbach 18-24 85452 Moosinning Germany The information presented in this data sheet does not form part

More information

Mounting Dimensions / Viewing 2 Mounting Options 3. Wiring Configuration 4. Quick Set up Procedure 5. Changing Intensity 6.

Mounting Dimensions / Viewing 2 Mounting Options 3. Wiring Configuration 4. Quick Set up Procedure 5. Changing Intensity 6. Section Mounting Dimensions / Viewing 2 Mounting Options 3 Section 2 Wiring Configuration 4 Section 3 Quick Set up Procedure 5 Section 4 Changing Intensity 6 Section 5 Option Summary 7 Section 6 Option

More information

LC0 DVP

LC0 DVP 2010-09-24 5012602300-2LC0.... DVP-1071070-01 POWER RUN ERROR L.V NET ZER O MAX MOTION NET ZER O MAX MOTION CH1 CH2 SHD SHD ENGLISH Thank you for choosing Delta s DVP series PLC. Delta releases DVP02LC-SL

More information

EL731 PROFIBUS INTERFACE

EL731 PROFIBUS INTERFACE Tel: +1-800-832-3873 E-mail: techline@littelfuse.com www.littelfuse.com/el731 EL731 PROFIBUS INTERFACE Revision 0-A-032816 Copyright 2016 Littelfuse Startco All rights reserved. Document Number: PM-1011-EN

More information

UniPak UP448 Bridge Input Isolating Signal Conditioner

UniPak UP448 Bridge Input Isolating Signal Conditioner 6-wire Bridge Connection Excitation for to 350 Ω Load Cells 500 Volt (3-way) Isolation Excellent Accuracy (0.0%) DIP Switch Configuration Digital Input Tare Calibration RS85 Modbus RTU Superior Flexible

More information

The LT1300 wall mount load cell indicator is a precision digital indicator for load cell and strain gauge applications.

The LT1300 wall mount load cell indicator is a precision digital indicator for load cell and strain gauge applications. LT1300 Wall Mount Load Cell Indicator Datasheet English 1.00 Introduction The LT1300 wall mount load cell indicator is a precision digital indicator for load cell and strain gauge applications. The high

More information

600 g x 0.02 g DIGITAL BALANCE

600 g x 0.02 g DIGITAL BALANCE 600 g x 0.02 g DIGITAL BALANCE Model : GM-600P Your purchase of this DIGITAL BALANCE marks a step forward for you into the field of precision measurement. Although this DIGITAL BALANCE is a complex and

More information

CONTENTS. PRECAUTIONS Introduction Installation... 7

CONTENTS. PRECAUTIONS Introduction Installation... 7 2 CONTENTS PRECAUTIONS... 4 1. Introduction... 6 2. Installation... 7 2.1 Unpacking... 7 2.2 Illustration of the installation for plastic shied... 7 2.3 Selecting the location... 8 2.4 Leveling the scale...

More information

ioselect Z-NET Z-SG Bridge Input Isolating I/O Module

ioselect Z-NET Z-SG Bridge Input Isolating I/O Module -wire Bridge Connection Excitation for to 30 Ω Load Cells 00 Volt (3-way) Isolation Excellent Accuracy (0.0%) DIP Switch Configuration Digital Input Tare Calibration RS8 Modbus RTU Superior Flexible Power:

More information

Chapter III Operation Instruction I. Start II. Key Operation III. Weighing Operation

Chapter III Operation Instruction I. Start II. Key Operation III. Weighing Operation Table of Contents Chapter I. Technical Parameter... - 2 - Chapter II Installation and Connection... - 3 - I. Indicator Diagram... - 3 - II. Loadcell Connection... - 4 - III. Serial Communication Interface

More information

TRWS series. Waterproof indicator User s guide UGTRWS-E1.1

TRWS series. Waterproof indicator User s guide UGTRWS-E1.1 TRWS series Waterproof indicator User s guide UGTRWS-E1.1 Table of Contents SECTION 1 INTRODUCTION 1 SECTION 2 SPECIFICATIONS.. 2 SECTION 3 INSTALLATION.3 SECTION 4 KEY DESCRIPTIONS 5 SECTION 5 DISPLAYS.6

More information

EHC-WF. User/Technical Manual. Contents subject to change without notice

EHC-WF. User/Technical Manual. Contents subject to change without notice EHC-WF User/Technical Manual Contents subject to change without notice Version 1.0 7/2017 TABLE OF CONTENTS 1. INTRODUCTION... 1 General and Safety Information... 1 Specifications... 1 2. Unpacking and

More information

805HP. Handheld Digital Weight Indicator User s Manual (v1703) Anyload Transducer Co. Ltd Website:

805HP. Handheld Digital Weight Indicator User s Manual (v1703) Anyload Transducer Co. Ltd Website: 805HP Handheld Digital Weight Indicator User s Manual (v1703) Anyload Transducer Co. Ltd Website: www.anyload.com Email: info@anyload.com TABLE OF CONTENTS 1. Introductions and Features 2 2. Safety Recommendations

More information

MWP SERIES. High Precision

MWP SERIES. High Precision MWP SERIES High Precision 1. INTRODUCTION------------------------------------------------1 2. INSTALLATION---------------------------------------------------2 2.1 Unpacking---------------------------------------------------------------

More information

North American Service Manual

North American Service Manual North American Service Manual MODEL PC SERIES Version 2 March 25, 1997 Revision B1.1 April 4, 2000 Prepared by TRANSCELL TECHNOLOGY, INC. TABLE OF CONTENTS Page Chapter 1: Introduction... 1-1 Chapter 2:

More information

21e. Multi-Function Indicator. Operation Manual (Full Version) PLEASE READ THIS MANUAL VERY CAREFULLY BEFORE OPERATING THIS INSTRUMENT

21e. Multi-Function Indicator. Operation Manual (Full Version) PLEASE READ THIS MANUAL VERY CAREFULLY BEFORE OPERATING THIS INSTRUMENT 21e Multi-Function Indicator Operation Manual (Full Version) PLEASE READ THIS MANUAL VERY CAREFULLY BEFORE OPERATING THIS INSTRUMENT Specifications subject to change without prior notice V128 October 2018

More information

IST ULTRASTAB Power Supply for IT/ITN ULTRASTAB transducers

IST ULTRASTAB Power Supply for IT/ITN ULTRASTAB transducers Power Supply for IT/ITN ULTRASTAB transducers High performance 6-channel power supply for multi-channel laboratory measurement applications. Features Current output or ±10 V voltage output Six individual

More information

User Manual. Waterproof Weighing Scale. ELW Plus / ESW Plus ELW Plus Wipower

User Manual. Waterproof Weighing Scale. ELW Plus / ESW Plus ELW Plus Wipower User Manual Waterproof Weighing Scale ELW Plus / ESW Plus ELW Plus Wipower Excell Precision Limited 2016. All rights reserved Worldwide. The information contained herein is the property of Excell Precision

More information

LCM SYSTEMS. TR150 Portable Battery Powered Indicator. Instruction Manual. Software version V2.XX

LCM SYSTEMS. TR150 Portable Battery Powered Indicator. Instruction Manual. Software version V2.XX TR50 Portable Battery Powered Indicator Instruction Manual Software version V2.XX CONTENTS What is TEDS? Basic concept How it works Advantages Introduction User operation Electrical connection information

More information

Vorne Industries. 2000S Series Serial Input Alphanumeric Display User's Manual

Vorne Industries. 2000S Series Serial Input Alphanumeric Display User's Manual Vorne Industries 2000S Series Serial Input Alphanumeric Display User's Manual 1445 Industrial Drive Itasca, IL 60143-1849 Telephone (630) 875-3600 Telefax (630) 875-3609 2000S Series Serial Input Alphanumeric

More information

RTD-500 Precision RTD Simulator. Operations Manual.

RTD-500 Precision RTD Simulator. Operations Manual. RTD-500 Precision RTD Simulator Operations Manual. Page 1 of 16 Table of Content. Table of Content....1 1 Scope...3 2 Package Content....3 3 Technical Data....3 4 Preparation for use....4 4.1 Switching

More information

TR150 Digital Readout Unit SL755. Impact Test Equipment Ltd & User Guide. User Guide

TR150 Digital Readout Unit SL755. Impact Test Equipment Ltd   &   User Guide. User Guide TR150 Digital Readout Unit SL755 Impact Test Equipment Ltd www.impact-test.co.uk & www.impact-test.com User Guide User Guide Impact Test Equipment Ltd. Building 21 Stevenston Ind. Est. Stevenston Ayrshire

More information

DRAFT. Customer site gravity factor. Filtering parameters. Five points for linearity correction to ensure maximum accuracy

DRAFT. Customer site gravity factor. Filtering parameters. Five points for linearity correction to ensure maximum accuracy Avery Weigh-Tronix Technical Specification Description General This specification describes the indicator, capable of stand-alone operation, or of integration into a larger system via serial interface.

More information

Specifications Digital Indicator 1. General

Specifications Digital Indicator 1. General Digital Indicator 1. General This instrument is the digital indicator suitable for butcher scale and the platform scale system. 2. Specifications 2-1. Specifications for analog Bridge power supply Applicable

More information

IST ULTRASTAB Power Supply for high precision transducers

IST ULTRASTAB Power Supply for high precision transducers IST ULTRASTAB Power Supply for high precision transducers High performance 6-channel power supply for multi-channel laboratory measurement applications. Features Current output or ±0 V voltage output (see

More information

Digital Weight Indicator Setup / Operation Manual

Digital Weight Indicator Setup / Operation Manual Digital Weight Indicator Setup / Operation Manual Revision 1.71 February 25, 2009 TABLE OF CONTENTS Page INTRODUCTION... 1 FCC NOTE... 1 INSTALLATION... 2 PREPARATION... 2 CONNECTIONS... 2 CONNECTING THE

More information

Instruction Manual. Instrument Amplifier HE 017

Instruction Manual. Instrument Amplifier HE 017 Instruction Manual Instrument Amplifier HE 017 List of contents INSTRUCTION MANUAL: HE 017 Date: 20.4.99 Art.-No.: 320999 S General Safety Instructions.......................................... S 1 General

More information