D6030S - D6030D INSTRUCTION MANUAL. D SIL 3 Switch/Proximity Detector Repeater Relay Output. Models D6030S, D6030D

Size: px
Start display at page:

Download "D6030S - D6030D INSTRUCTION MANUAL. D SIL 3 Switch/Proximity Detector Repeater Relay Output. Models D6030S, D6030D"

Transcription

1 D600S - D600D INSTRUCTI MANUAL SIL Switch/Proximity Detector Repeater Relay, DIN Rail, Models D600S, D600D D600 - SIL Switch/Proximity Detector Repeater Relay G.M. International ISM0-

2 Characteristics General Description: The single and dual channel Switch/Proximity Detector Repeater, D600S and D600D module is a unit suitable for applications requiring SIL level (according to IEC 60:00 Ed. ) in safety related systems for high risk industries. The unit can be configured for switch or proximity detector (EN60--6, NAMUR), or NC and for NE or SPST (D600D) or SPDT (D600S) relay output contact. Each channel enables a load to be controlled by a switch, or a proximity detector. Fault detection circuit (DIP switch configurable) is available for both proximity sensor and switch equipped with end of line resistors. In case of fault, when enabled it de-energizes the corresponding output relay and turns the fault LED on; when disabled the corresponding output relay repeats the input line open or closed status as configured. D600D is programmable via dip switches as single input and two independent outputs. Out can be programmed for output duplicating Out or Fault detection Out. In case of duplication, relay actuation can be independently configured for each output. In case of fault output, relay actuation can be programmed as normally energized or normally de-energized. Mounting on standard DIN-Rail, with or without Power Bus. Functional Safety Management Certification: G.M. International is certified by TÜV to conform to IEC60:00 part clauses -6 for safety related systems up to and included SIL. FSM SIL Technical Data Supply: Vdc nom ( to 0 Vdc) reverse polarity protected, ripple within voltage limits Vpp, A time lag fuse internally protected. Current V: ma for channels D600D, ma for channel D600S with short circuit input and relay energized, typical. Power dissipation: 0. W for channels D600D, 0. W for channel D600S with V supply voltage, short circuit input and relay energized, typical. Isolation (Test Voltage): In/Out. KV; In/Supply. KV; In/ In 00 V; Out/Supply. KV; Out/Out. KV. switching current levels:. ma (. to 6. ma range),. ma (0. to. ma range), switch current.6 ma ± 0. ma hysteresis. Fault current levels: open fault 0. ma, short fault 6. ma (when enabled both faults de-energize channel relay with single channel unit D600S or de-energize channel relay with D600D used as dual channel unit or actuate the fault relay out with D600D used as fault signaling unit). equivalent source: V KΩ typical ( V no load, ma short circuit). : SPST (D600D) or SPDT (D600S) relay contact. material: Ag Alloy (Cd free), gold plated. rating: A 0 Vac 000 VA, A 0 Vdc 0 W (resistive load), limit current to 00 ma maximum for SIL applications. Min.switching current ma. DC Load breaking capacity: V (V) Resistive Load SIL Area Mechanical / Electrical life: * 0 6 / * 0 operation, typical. Operate / Release time: / ms typical. Bounce time / NC contact: / ms typical. Frequency response: 0 Hz maximum. Compatibility: CE mark compliant, conforms to Directive: 0/0/EU EMC, 0//EU LVD, 0/6/EU RoHS. Environmental conditions: Operating: temperature limits 0 to + 0 C, relative humidity %, up to C. Storage: temperature limits to + 0 C. Approvals: I (A) TÜV Certificate No. C-IS-60-0, SIL / SIL conforms to IEC60:00 Ed.. TÜV Certificate No. C-IS-6-0, SIL Functional Safety Certificate conforms to IEC60:00 Ed., for Management of Functional Safety. Mounting: T DIN-Rail according to EN00, with or without Power Bus. Weight: about 0 g D600D, 0 g D600S. Connection: by polarized plug-in disconnect screw terminal blocks to accommodate terminations up to. mm. Protection class: IP 0. Dimensions: Width. mm, Depth mm, Height 0 mm. D600 - SIL Switch/Proximity Detector Repeater Relay G.M. International ISM0-

3 Model: D600 channel S channels D Ordering Information Front Panel and Features SIL according to IEC 60:00 Ed. for Tproof / 0 years ( 0% / >0 % of total SIF), considering 00 ma max contact current. PFDavg ( year). E-0, SFF 0.06 %, with independent channel configuration. PFDavg ( year).6 E-0, SFF.6 %, with D600D used as duplicator (both channels) or as fault indicator (only st ch.). PFDavg ( year).66 E-0, SFF. %, with D600D used as fault indicator (only nd ch.). SIL according to IEC 60:00 Ed. for Tproof / 0 years ( 0% / >0 % of total SIF), considering A max contact current. PFDavg ( year). E-0, SFF. %, with independent channel configuration. PFDavg ( year). E-0, SFF.0 %, with D600D used as duplicator (both channels) or as fault indicator (only st ch.). PFDavg ( year).6 E-0, SFF.0 %, with D600D used as fault indicator (only nd ch.). Systematic capability SIL fully independent channels. High Density, channels per unit. /NC switch/proximity Detector, NE/ relay actuation mode. Field open and short circuit detection. Three port isolation, //Supply. EMC Compatibility to EN , EN , EN66-, EN66-- for safety system. In-field programmability by DIP Switch. TÜV Certification. TÜV Functional Safety Certification. Power Bus and DIN-Rail accessories: Connector JDFT0 Cover and fix MCHP6 Terminal block male M0 Terminal block female M0 Simplified installation using standard DIN-Rail and plug-in terminal blocks, with or without Power Bus. Terminal block connections Ch for Proximity or Voltage free Ch - Ch for Proximity or Voltage free Ch + Ch for Proximity or Voltage free Ch 0 - Ch for Proximity or Voltage free Ch + Power Supply Vdc 6 - Power Supply Vdc G.M. International ISM0- D600 - SIL Switch/Proximity Detector Repeater Relay

4 Function Diagram R R Proximity + - MODEL D600D D00D + Supply Vdc 6 - Out (SIL ) In R R Proximity Out (SIL ) In Resistors R - R used with contact required for line fault detection. Terminals -0 must be shorted to set module as Duplicator or Fault Out F - + Power and Fault Bus MODEL D00D D600D Duplicator or or Fault Out Relay contacts shown in de-energized position. Terminals - and - open. R R Proximity Supply Vdc 6 - Out (SIL ) In 0 Out Duplicator or Fault (SIL ) Resistors R - R used with contact required for line fault detection. F - + Power and Fault Bus Internal Dip switches programmable Relay contacts shown in de-energized position. Terminals - and - open. MODEL D600S D00S R R Proximity Supply Vdc 6 - Out (SIL ) In Out NC (SIL ) Resistors R - R used with contact required for line fault detection. F - + Power and Fault Bus Relay contact shown in de-energized position. Terminals - open, terminals - close. D600 - SIL Switch/Proximity Detector Repeater Relay G.M. International ISM0-

5 Warning D600 series must be installed, operated and maintained only by qualified personnel, in accordance to the relevant national/international installation standards. Failure to properly installation or use of the equipment may risk to damage the unit or severe personal injury. The unit cannot be repaired by the end user and must be returned to the manufacturer or his authorized representative. Any unauthorized modification must be avoided. D600 module is a unit suitable for applications requiring SIL level (according to IEC 60) in safety related systems for high risk industries. The unit can be configured for switch or proximity detector (EN60--6, NAMUR), or NC and for NE or SPST (D600D) or SPDT (D600S) relay output contact. Each channel enables a load to be controlled by a switch, or a proximity detector. Fault detection circuit (DIP switch configurable) is available for both proximity sensor and switch equipped with end of line resistors. In case of fault, when enabled it de-energizes the corresponding output relay and turns the fault LED on; when disabled the corresponding output relay repeats the input line open or closed status as configured. D600D is programmable via dip switches as single input and two independent outputs. Out can be programmed for output duplicating Out or Fault detection Out. In case of duplication, relay actuation can be independently configured for each output. In case of fault output, relay actuation can be programmed as normally energized or normally de-energized. Presence of supply power and status of output (energized or de-energized), as well as integrity or fault condition of sensor and connecting line are displayed by signaling LEDs (green for power, yellow for status and red for fault condition). Note: use of electrical contacts with fault detection enabled (control equipment) requires, near the switch at the end of the line a R KΩ typical (0 Ω to KΩ range) resistor in series and a R0 kω typical ( KΩ to KΩ range) resistor in parallel to the contacts in order to allow the fault detection circuit to distinguish between a condition of contact close/open and a line open/short circuit fault. Installation D600 series are Switch/Proximity Detector Interface housed in a plastic enclosure suitable for installation on T DIN-Rail according to EN00, with or without Power Bus. D600 unit can be mounted with any orientation over the entire ambient temperature range. Electrical connection of conductors up to. mm² are accommodated by polarized plug-in removable screw terminal blocks which can be plugged in/out into a powered unit without suffering or causing any damage. The wiring cables have to be proportionate in base to the current and the length of the cable. On the section Function Diagram and enclosure side a block diagram identifies all connections. Identify the number of channels of the specific card (e.g. D600S is a single channel model and D600D is a dual channel model), the function and location of each connection terminal using the wiring diagram on the corresponding section, as an example: Connect Vdc power supply positive at terminal and negative at terminal 6. For Model D600S connect output of channel at terminals and (for contact) or at terminals and (for NC contact). For Model D600D in addition to channel connections above, connect output of channel at terminals and. For Model D600S, in case of Proximity or Voltage free, connect the wires at terminal for positive and for negative. For Model D600D in addition to channel connections above, connect terminal for positive and 0 for negative on channel. Connect SPDT (D600S) or SPST (D600D) relay contacts checking the load rating to be within the contact maximum rating ( A 0 Vac 000 VA, A 0 Vdc 0 W resistive load, limit current to 00 ma maximum for SIL applications). If necessary, to prevent relay contacts from damaging, an external protection (fuse or similar) should be connected. A suitable protection must be chosen according to the relay breaking capacity diagram on data sheet. Units must be protected against dirt, dust, extreme mechanical (e.g. vibration, impact and shock) and thermal stress, and casual contacts. If enclosure needs to be cleaned use only a cloth lightly moistened by a mixture of detergent in water. Any penetration of cleaning liquid must be avoided to prevent damage to the unit. Any unauthorized card modification must be avoided. According to EN600, D600 series must be connected to SELV or SELV-E supplies. Relay output contact must be connected to load non exceeding category II overvoltage limits. Warning: de-energize main power source (turn off power supply voltage) and disconnect plug-in terminal blocks before opening the enclosure to avoid electrical shock when connected to live hazardous potential. Start-up Before powering the unit check that all wires are properly connected, particularly supply conductors and their polarity, input and output wires. Check conductors for exposed wires that could touch each other causing dangerous unwanted shorts. Turn on power, the power on green led must be lit, status and fault led on each channel must be in accordance with condition of the corresponding input line. If possible close and open input lines one at time checking the corresponding status and fault LEDs condition as well as output to be correct. G.M. International ISM0- D600 - SIL Switch/Proximity Detector Repeater Relay

6 D600D used as double channel A configuration DIP switch is located on component side of pcb. This switch allows the configuration of input/output relationship, fault detection functions and operating mode. WARNING: dip-switch 6-- must be set to position. Configuration Dip switch factory settings. All Switches are 6 Dip switch configuration CH 6 CH Must be set to "" position CH Setting Line fault detection (switch / proximity sensor) Enabled (proximity sensor or switch with end of line resistors, Position in fault condition IN / OUT -NE or NC- NE NC - or NC-NE NC NE CH Setting Line fault detection (switch / proximity sensor) Enabled (proximity sensor or switch with end of line resistors, Position in fault condition IN / OUT -NE or NC- NE NC or NC-NE NC NE D600 - SIL Switch/Proximity Detector Repeater Relay G.M. International ISM0-

7 Configuration D600D used as duplicator or fault output A configuration DIP switch is located on component side of pcb. This switch allows the configuration of input/output relationship, fault detection functions and operating mode. WARNING: Terminals -0 must be shorted to set module as Duplicator or Fault Out. Dip-switch must be set to position. Dip switch factory settings. All Switches are 6 Dip switch configuration 6 CH Setting Line fault detection IN / OUT (switch / proximity sensor) Enabled (proximity sensor or switch with end of line resistors, -NE or NC- NE Must be set to "" position NC Position in fault condition, De-energized in fault condition, not specified fault condition - or NC-NE NC NE Duplicator Position in fault condition 6 De-energized in fault condition if line fault detection enabled (SW ) Parallel Mode Set SW equal to SW 6 Not specified fault condition Reverse Mode Set SW opposite to SW Fault 6 Mode NE Mode No Fault No Fault NE Fault condition Fault condition G.M. International ISM0- D600 - SIL Switch/Proximity Detector Repeater Relay

8 D600S A configuration DIP switch is located on component side of pcb. This switch allows the configuration of input/output relationship, fault detection functions and operating mode. WARNING: Dip-switch - must be set to position. Configuration Dip switch factory settings. All Switches are 6 Dip switch configuration 6 - must be set to "" position --6 Not used CH Setting Line fault detection (switch / proximity sensor) Enabled (proximity sensor or switch with end of line resistors, Position in fault condition - IN / OUT -NE or NC- NE - NC - - or NC-NE - NC NE - D600 - SIL Switch/Proximity Detector Repeater Relay G.M. International ISM0-

9 Configuration DIP Switch factory settings (valid for D600S and D600D) SW SW SW SW SW SW6 SW SW D600D (used as double channel) Configuration Summary Table WARNING: dip-switch 6-- must be set to position. Channel Line fault detection SW SW SW Channel IN/OUT SW SW (switch/proximity sensor) -NE or NC- Enabled, for SIL application (proximity sensor or switch with end of line resistors, detects field open circuit and short circuit, - or NC-NE D600D (used as duplicator or fault output) Configuration Summary Table WARNING: Terminals -0 must be shorted to set module as Duplicator or Fault Out. Dip-switch must be set to position. Line fault detection SW SW IN/OUT SW (switch/proximity sensor) Enabled, for SIL application (proximity sensor or switch with end of line resistors, detects field open circuit and short circuit,, De-energized in Fault condition, Not specified Fault condition -NE or NC- - or NC-NE SW6 SW SW Mode SW Duplicator De-energized in fault condition if line fault detection enabled (SW ) Parallel (for SIL application) Set equal to SW Not specified Fault condition Reverse Set opposite to SW Fault NE (for SIL application) D600S Configuration Summary Table WARNING: Dip-switch - must be set to position. Line fault detection SW SW IN/OUT SW (switch/proximity sensor) -NE or NC- Enabled, for SIL application (proximity sensor or switch with end of line resistors, detects field open circuit and short circuit, - or NC-NE G.M. International ISM0- D600 - SIL Switch/Proximity Detector Repeater Relay

INSTRUCTION MANUAL. SIL 3 Switch/Proximity Detector Repeater Relay Output, Termination Board Models D6032S, D6032D

INSTRUCTION MANUAL. SIL 3 Switch/Proximity Detector Repeater Relay Output, Termination Board Models D6032S, D6032D D603S D603D INSTRUCTI MANUAL SIL 3 Switch/Proximity Detector Repeater Relay, Termination Board Models D603S, D603D D603 SIL 3 Switch/Proximity Detector Repeater Relay G.M. International ISM0400 General

More information

INSTRUCTION MANUAL. SIL 3 Relay Output Module DIN-Rail Models D1092S-069, D1092D-069 D1092S D1092D-069

INSTRUCTION MANUAL. SIL 3 Relay Output Module DIN-Rail Models D1092S-069, D1092D-069 D1092S D1092D-069 D09S09 D09D09 INSTRUCTION MANUAL SIL Relay Output Module DINRail Models D09S09, D09D09 D0909 SIL Relay Output Module ISM00 SIL Applications For Safety Related System and SIL, SIL Applications according

More information

D5090S INSTRUCTION MANUAL. D A SIL 3 Relay Output Module for NE Load. DIN-Rail and Termination Board, Model D5090S

D5090S INSTRUCTION MANUAL. D A SIL 3 Relay Output Module for NE Load. DIN-Rail and Termination Board, Model D5090S D5090S INSTRUCTI MANUAL 4 A Relay Output Module for NE, DIN-Rail and Termination Board, Model D5090S D5090-4 A Relay Output Module for NE G.M. International ISM09-3 Characteristics General Description:

More information

D1093S INSTRUCTION MANUAL. D SIL 3 Relay Output Module with Line and Load diagnostics. DIN-Rail Model D1093S

D1093S INSTRUCTION MANUAL. D SIL 3 Relay Output Module with Line and Load diagnostics. DIN-Rail Model D1093S D109S INSTRUCTION MANUAL SIL Relay Output Module with Line and diagnostics DINRail Model D109S D109 SIL Relay Output Module with Line and diagnostics ISM0096 SIL Applications For Safety Related System

More information

INSTRUCTION MANUAL. Universal AC Input Switching Power Supply 24 Vdc Output DIN-Rail Models PSD1000, PSD1000F PSD PSD1000F

INSTRUCTION MANUAL. Universal AC Input Switching Power Supply 24 Vdc Output DIN-Rail Models PSD1000, PSD1000F PSD PSD1000F PSD1000 - PSD1000F INSTRUCTION MANUAL Universal AC Input Switching Power Supply 24 Vdc Output DIN-Rail Models PSD1000, PSD1000F PSD1000 - Universal AC Input Switching Power Supply 24 Vdc Output ISM0089-4

More information

INSTRUCTION MANUAL. D SIL 3 Switch/Proximity Detector Repeater Relay Output. Models D5030S, D5030D D5030S - D5030D.

INSTRUCTION MANUAL. D SIL 3 Switch/Proximity Detector Repeater Relay Output. Models D5030S, D5030D D5030S - D5030D. D00S - D00D HM-0 INSTRUCTI MANUAL SIL Switch/Proximity Detector Repeater Relay, DIN Rail, Models D00S, D00D www.hemomatik.se Ordertel 0-00 0 Växel 0-0 0 Orderfax 0-6 00 Teknisk 0-0 Länna, S- 0 SKOGÅS (Stockholm)

More information

INSTRUCTION & SAFETY MANUAL

INSTRUCTION & SAFETY MANUAL D5091S INSTRUCTION & SAFETY MANUAL 5 A SIL 3 Relay Output Module for ND with ND or NE Relay condition DIN-Rail and Termination Board, Model D5091S D5091-5 A SIL 3 Relay Output Module for ND with ND or

More information

D1080D INSTRUCTION MANUAL. D Flammable Liquid Presence Detector Interface Relay Output. DIN-Rail Model D1080D

D1080D INSTRUCTION MANUAL. D Flammable Liquid Presence Detector Interface Relay Output. DIN-Rail Model D1080D D080D INSTRUCTI MANUAL Flammable Liquid Presence Detector Interface Relay Output DINRail Model D080D D080 Flammable Liquid Presence Detector Interface Relay Output ISM00559 Characteristics General Description:

More information

D1080D INSTRUCTION MANUAL. D Flammable Liquid Presence Detector Interface Relay Output. DIN-Rail Model D1080D

D1080D INSTRUCTION MANUAL. D Flammable Liquid Presence Detector Interface Relay Output. DIN-Rail Model D1080D D080D INSTRUCTI MANUAL Flammable Liquid Presence Detector Interface Relay Output DINRail Model D080D D080 Flammable Liquid Presence Detector Interface Relay Output ISM00558 Characteristics General Description:

More information

INSTRUCTION MANUAL. SIL 2 Switch / Proximity Detector Repeater, Open Collector Output DIN-Rail and Termination Board, Model D5231E

INSTRUCTION MANUAL. SIL 2 Switch / Proximity Detector Repeater, Open Collector Output DIN-Rail and Termination Board, Model D5231E D5231E INSTRUCTION MANUAL SIL 2 Switch / Proximity Detector Repeater, Open Collector put DINRail and Termination Board, Model D5231E D5231E SIL 2 Switch/Proximity Detector Repeater, O.C. put G.M. International

More information

INSTRUCTION MANUAL. Switch/Proximity Detector Repeater Relay Output DIN-Rail Models D1030S, D1030D D1030S - D1030D

INSTRUCTION MANUAL. Switch/Proximity Detector Repeater Relay Output DIN-Rail Models D1030S, D1030D D1030S - D1030D D00S D00D INSTRUCTI MANUAL Switch/Proximity Detector Repeater Relay DINRail Models D00S, D00D D00 Switch / Proximity Detector Repeater Relay ISM0000 Characteristics General Description: The Switch/Proximity

More information

INSTRUCTION & SAFETY MANUAL

INSTRUCTION & SAFETY MANUAL D5034S D5034D INSTRUCTION & SAFETY MANUAL SIL 3 Switch/ Interface DINRail and Termination Board Models D5034S, D5034D D5034 SIL 3 Switch/ Interface G.M. International ISM01137 Characteristics General Description:

More information

PI-EX-ME-2NAM/COC-120VAC

PI-EX-ME-2NAM/COC-120VAC PI-EX-ME-NAM/COC-0VAC Ex-i NAMUR Isolation Amplifier, With Intrinsically Safe Input and Relay Output, PDT, Two-Channel, 0 V AC Supply INTERFACE Data Sheet 0944_00_en PHOENIX CONTACT - 0/008 Description

More information

PI-EX-ME-2NAM/COC-24VDC

PI-EX-ME-2NAM/COC-24VDC Ex-i NAMUR Isolation Amplifier, With Intrinsically Safe Input and Relay Output, PDT, Two-Channel, 4 V DC Supply INTERFACE Data Sheet 0033_0_en PHOENIX CONTACT - /007 Description The PI-EX-ME-NAM/COC-4VDC

More information

PHOENIX CONTACT - 12/2007

PHOENIX CONTACT - 12/2007 Ex-i NAMUR Isolation Amplifier, With Intrinsically Safe Input and Active Transistor Output, Two-Channel INTERFACE Data Sheet 0943_00_en PHOENIX CONTACT - /007 Description The PI-EX-ME-NAM/TO-A is a two-channel

More information

Operating instructions Evaluation system for flow sensors VS / / 2013

Operating instructions Evaluation system for flow sensors VS / / 2013 Operating instructions Evaluation system for flow sensors VS3000 7097 / 0 07 / 203 Contents Preliminary note...2 2 Safety instructions...3 3 Function and features... Mounting.... Mounting of the sensors...

More information

INTRINSICALLY SAFE INSTRUMENTATION FOR HAZARDOUS AREAS

INTRINSICALLY SAFE INSTRUMENTATION FOR HAZARDOUS AREAS INTRINSICALLY SAFE INSTRUMENTATION FOR HAZARDOUS AREAS SHORT FORM 2002 SERIES D1000 Intrinsically Safe Galvanic Isolators SERIES D1000, for DIN Rail Mounting, provide the most simple and cost effective

More information

TURCK Process Automation IS Interface Technology. Interface Modules. IM Series Cabinet

TURCK Process Automation IS Interface Technology. Interface Modules. IM Series Cabinet Process Automation IS Interface Technology Interface Modules TURCK's IM series of Isolating Intrinsically Safe Barriers is designed to be a simple and safe way to solve the problems associated with the

More information

XPSMCMDI Input expansion module with screw term

XPSMCMDI Input expansion module with screw term Characteristics 16 Input expansion module with screw term Main Range of product Product or component type Device short name Electrical connection [Us] rated supply voltage Number of inputs Number of outputs

More information

XPSMCMDO Digital output pairs expansion modules with screw term

XPSMCMDO Digital output pairs expansion modules with screw term Characteristics 2 Digital output pairs expansion modules with screw term Main Range of product Product or component type Device short name Electrical connection [Us] rated supply voltage Number of inputs

More information

English. Operating manual. Limit switch GS125. Keep for future reference. Ventures / brands of GHM

English. Operating manual. Limit switch GS125.  Keep for future reference. Ventures / brands of GHM English Operating manual Limit switch GS125 Ventures / brands of GHM www.ghm-messtechnik.de Keep for future reference. Table of contents Page 1. Intended use (areas of application)... 3 1.1 Safety signs

More information

Operating instructions. Speed monitor D / / 2014

Operating instructions. Speed monitor D / / 2014 Operating instructions Speed monitor D200 80005257 / 00 05 / 2014 Contents 1 Preliminary note...4 1.1 Symbols used...4 1.2 Warning signs used...4 2 Safety instructions...5 2.1 General...5 2.2 Target group...5

More information

English. Operating manual. Universal transmitter UT125. Save for later reference. Companies / brands of GHM

English. Operating manual. Universal transmitter UT125.  Save for later reference. Companies / brands of GHM English Operating manual Universal transmitter UT125 Companies / brands of GHM www.ghm-messtechnik.de Save for later reference. Table of contents page 1. Intended use (areas of application)... 3 1.1 Safety

More information

Operating instructions. Switching amplifier DN0210 DN / / 2015

Operating instructions. Switching amplifier DN0210 DN / / 2015 Operating instructions Switching amplifier DN0210 DN0220 UK 80011079 / 00 01 / 2015 Contents 1 Preliminary note...4 1.1 Symbols used...4 1.2 Warning signs used...4 2 Safety instructions...5 2.1 General...5

More information

Assembly. Front view. LED yellow/red: Status output Ι/ Fault signal Function. Switch Power Rail

Assembly. Front view. LED yellow/red: Status output Ι/ Fault signal Function. Switch Power Rail Switch Amplifier KCD-SR-Ex.LB Features Assembly -channel isolated barrier V DC supply (Power Rail) Dry contact or NAMUR inputs Usable as signal splitter ( input and outputs) Relay contact output Fault

More information

MACX MCR-EX-SL-NAM-2RO(-SP)

MACX MCR-EX-SL-NAM-2RO(-SP) Intrinsically safe NAMUR isolating amplifier with two relay outputs INTERFACE Data sheet 03465_en_00 PHOENIX CONTACT - 08/008 Description The NAMUR MACX MCR-EX-SL-NAM-RO(-SP) isolating amplifier has been

More information

OPERATING INSTRUCTIONS 7 SERIES STATIC GENERATORS

OPERATING INSTRUCTIONS 7 SERIES STATIC GENERATORS OPERATING INSTRUCTIONS 7 SERIES STATIC GENERATORS GB Contents Page 1 Introduction 4 2 Safety 5 3 Use 6 4 Checking on Delivered Equipment 6 5 General Specification and Dimensions 7 6 Positioning 10 7 Operating

More information

Assembly. Front view. LED yellow: Relay output. LED red: LB/SC Power Rail

Assembly. Front view. LED yellow: Relay output. LED red: LB/SC Power Rail Switch Amplifier Features Assembly -channel isolated barrier 4 V DC supply (Power Rail) Dry contact or NAMUR inputs Relay contact output Line fault detection (LFD) Reversible mode of operation Up to SIL

More information

APPLICATION GUIDE. Interface Modules IM Series.

APPLICATION GUIDE. Interface Modules IM Series. Interface Modules IM Series APPLICATION GUIDE www.turck.com Interface Technology Interface Modules TURCK's IM series of Isolating Intrinsically Safe Barriers is designed to be a simple and safe way to

More information

MACX MCR-EX-SL-NAM-R(-SP)

MACX MCR-EX-SL-NAM-R(-SP) Intrinsically safe NAMUR isolating amplifier with relay output INTERFACE Data sheet 03463_en_00 PHOENIX CONTACT - 08/2008 Description The NAMUR MACX MCR-EX-SL-NAM-R(-SP) isolating amplifier has been designed

More information

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at Safety Instructions WARNING Follow carefully this safety and installation instructions. Improper work may lead to serious harmful for your health and also may damage seriously the IntesisBox and/or any

More information

Datasheet SRB301ST 24V (V.2)

Datasheet SRB301ST 24V (V.2) 26.10.2016 05:03:31h Datasheet SRB301ST 24V (V.2) Guard door monitors and Safety control modules for Emergency Stop applications / General Purpose safety controllers (Series PROTECT SRB) / SRB301ST Suitable

More information

XPSMCMMX inputs 2 output pairs expansion module with screw term

XPSMCMMX inputs 2 output pairs expansion module with screw term Characteristics 8 inputs 2 output pairs expansion module with screw term Main Range of product Product or component type Device short name Electrical connection [Us] rated supply voltage Number of inputs

More information

ICS Regent. Relay Output Modules. Low Power and High Power (T3446L and T3446H) PD-6017

ICS Regent. Relay Output Modules. Low Power and High Power (T3446L and T3446H) PD-6017 ICS Regent PD-6017 Relay Output Modules Low Power and High Power (T3446L and T3446H) Issue 1, March, 06 Relay output modules provide control of eight user output loads. Two types of relay output modules

More information

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at Safety Instructions WARNING Follow carefully this safety and installation instructions. Improper work may lead to serious harmful for your health and also may damage seriously the IntesisBox and/or any

More information

See instructions to download and install the latest version of LinkBoxLON and the user's manual at

See instructions to download and install the latest version of LinkBoxLON and the user's manual at Safety Instructions WARNING Follow carefully this safety and installation instructions. Improper work may lead to serious harmful for your health and also may damage seriously the IntesisBox and/or any

More information

TM7NCOM16A CANopen interface block - IP67-16 I/O - M12

TM7NCOM16A CANopen interface block - IP67-16 I/O - M12 Characteristics CANopen interface block - IP67-16 I/O - M12 Main Range of product Product or component type Range compatibility Enclosure material Bus type [Ue] rated operational voltage Input/Output number

More information

Technical data. Dimensions: see page 116. ): 4 kv Rated insulation voltage (U i Over-voltage category: Power supply. Rated operating voltage (Un):

Technical data. Dimensions: see page 116. ): 4 kv Rated insulation voltage (U i Over-voltage category: Power supply. Rated operating voltage (Un): Safety module CS AR-91, according to EN 81 Safety modules for the lift automatic floor levelling operation according to EN 81 Main functions For safety applications up to SIL 3 / PL e Choice between automatic

More information

Inductive sensor Dual sensors with extended temperature range NI4-DSU35TC-2Y1X2/S97

Inductive sensor Dual sensors with extended temperature range NI4-DSU35TC-2Y1X2/S97 ATEX category II 2 G, Ex zone 1 ATEX category II 1 D, Ex-zone 20 for temperatures up to -25 C SIL2 acc. to IEC 61508 Rectangular, housing DSU35 Plastic, PP-GF30-VO Two outputs for monitoring the position

More information

English. Operating Manual. Conductive point level switch MLR120. Retain for later reference. Companies / brands of GHM

English. Operating Manual. Conductive point level switch MLR120.  Retain for later reference. Companies / brands of GHM English Operating Manual Conductive point level switch MLR120 Companies / brands of GHM www.ghm-group.de Retain for later reference Table of contents Page 1. Proper use (application areas)... 3 Safety

More information

Datasheet - SRB 301LC/B-24V

Datasheet - SRB 301LC/B-24V 27.01.2016-00:27:16h Datasheet - SRB 301LC/B-24V Guard door monitors and Safety control modules for Emergency Stop applications / General Purpose safety controllers (Series PROTECT SRB) / SRB 301LC/B Fit

More information

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016 Operating instructions AS-i SmartLine module AC3200 AC3201 80237876/00 06/2016 Contents 1 Preliminary note...3 1.1 Symbols used...3 1.2 Warnings used...3 2 Safety instructions...3 2.1 General...3 2.2 Target

More information

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

See instructions to download and install the latest version of LinkBoxMB and the user's manual at Safety Instructions WARNING Follow carefully this safety and installation instructions. Improper work may lead to serious harmful for your health and also may damage seriously the IntesisBox and/or any

More information

RM35UB3. Product data sheet Characteristics. voltage control relay RM35-U - range V AC. Main. Complementary

RM35UB3. Product data sheet Characteristics. voltage control relay RM35-U - range V AC. Main. Complementary Characteristics voltage control relay RM35-U - range 194..528 V AC Main Range of product Product or component type Relay type Product specific application Relay name Relay monitored parameters Time delay

More information

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

See instructions to download and install the latest version of LinkBoxMB and the user's manual at Safety Instructions WARNING Follow carefully this safety and installation instructions. Improper work may lead to serious harmful for your health and also may damage seriously the IntesisBox and/or any

More information

Datasheet - SRB 402EM-24V

Datasheet - SRB 402EM-24V Print - Create PDF - Create EXCEL file 20.04.2011-18:31:35h Datasheet - SRB 402EM-24V Output expanders / SRB 402EM Expander module for contact expansion 4 safety contacts, STOP 0 2 Signalling outputs (Minor

More information

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector Characteristics expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector Main Range of product Product or component type Range compatibility Enclosure material Bus type [Ue] rated operational

More information

RM35TF V AC

RM35TF V AC Characteristics multifunction phase control relay RM35-T - range 194..528 V AC Main Range of product Product or component type Relay type Product specific application Relay name Relay monitored parameters

More information

Inductive dual sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933

Inductive dual sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933 ATEX category II 2 G, Ex zone 1 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Rectangular, housing DSU35 Plastic, PP-GF30-VO Two outputs for monitoring the position of rotary actuators Mounting

More information

Inductive sensor For rotary actuators NI4-DSU35-2Y1X2-H1140

Inductive sensor For rotary actuators NI4-DSU35-2Y1X2-H1140 ATEX category II 2 G, Ex zone 1 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

See instructions to download and install the latest version of LinkBoxMB and the user's manual at Safety Instructions WARNING Follow carefully this safety and installation instructions. Improper work may lead to serious harmful for your health and also may damage seriously the IntesisBox and/or any

More information

RM17UAS. Product datasheet Characteristics. voltage control relay RM17-U - range V DC. Main. Complementary. Price* : 70.

RM17UAS. Product datasheet Characteristics. voltage control relay RM17-U - range V DC. Main. Complementary. Price* : 70. Characteristics voltage control relay RM17-U - range 9..15 V DC Price* : 70.64 GBP Main Range of product Product or component type Relay type Product specific application Relay name Relay monitored parameters

More information

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

See instructions to download and install the latest version of LinkBoxMB and the user's manual at Safety Instructions WARNING Follow carefully this safety and installation instructions. Improper work may lead to serious harmful for your health and also may damage seriously the IntesisBox and/or any

More information

VEO. V2PF480Y/277VSY01 Art.Nr.: V2PF480Y/277VSY01P Art.Nr.: TECHNICAL DATA

VEO. V2PF480Y/277VSY01 Art.Nr.: V2PF480Y/277VSY01P Art.Nr.: TECHNICAL DATA Monitoring of phase sequence and phase loss Monitoring of asymmetry Supply voltage 208-480 V AC Supply circuit = measuring circuit 1 change-over contact Width 22,5 mm Control elements Asymmetry Status

More information

RM17UB3. Product data sheet Characteristics. voltage control relay RM17-U - range V AC. Main. Complementary

RM17UB3. Product data sheet Characteristics. voltage control relay RM17-U - range V AC. Main. Complementary Characteristics voltage control relay RM17-U - range 183..528 V AC Main Range of product Product or component type Relay type Product specific application Relay name Relay monitored parameters Time delay

More information

MINI MCR-SL-UI-2I. Configurable signal duplicator. Data sheet. 1 Description

MINI MCR-SL-UI-2I. Configurable signal duplicator. Data sheet. 1 Description Configurable signal duplicator Data sheet 102382_en_03 PHOENIX CONTACT 2012-05-02 1 Description The MINI MCR-SL-UI-2I(-SP)(-NC) configurable signal duplicator is used to electrically isolate, condition,

More information

BMX DDM Mixed Relay Input/Output module

BMX DDM Mixed Relay Input/Output module Modicon M340 Using Unity Pro BMX DDM 16025 35012474 07/2012 BMX DDM 16025 Mixed Relay Input/Output module 22 Subject of this Section This section presents the BMX DDM 16025 module, its characteristics,

More information

Operating Instructions. Intrinsically Safe Isolation Relay for Switches Model: REL manual_rel-6_0505

Operating Instructions. Intrinsically Safe Isolation Relay for Switches Model: REL manual_rel-6_0505 Operating Instructions Intrinsically Safe Isolation Relay for Switches Model: REL-6003 manual_rel-6_0505 1. Contents 1. Contents...2 2. Note...3 3. Instrument Inspection...3 4. Regulation Use...3 5. Operating

More information

Inductive sensor For rotary actuators NI4-DSU35TC-2Y1X2

Inductive sensor For rotary actuators NI4-DSU35TC-2Y1X2 ATEX category II 2 G, Ex zone 1 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

Compact Coded Magnetic Safety Interlock Switch and Control Units

Compact Coded Magnetic Safety Interlock Switch and Control Units C Conforms to EN292, EN60204-1, EN954-1, EN1088, EN60947-5-3, EN947-5-3, EN50081, EN50082, EN61000-6-2 UL and C-UL listed, TUV certified Description R US Compact Coded Magnetic Safety Interlock Switch

More information

Inductive sensor NI3-EG08K-Y1-H1341

Inductive sensor NI3-EG08K-Y1-H1341 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Threaded barrel, M8 x 1 Stainless steel, 1.4427 SO DC 2-wire, nom. 8.2 VDC Output acc. to DIN EN 60947-5-6 (NA- MUR)

More information

SIL 2/3 Relays for all applications, with or without Line & Load Diagnostics. Product presentation

SIL 2/3 Relays for all applications, with or without Line & Load Diagnostics. Product presentation SIL 2/3 for all applications, with or without Line & Load Diagnostics Product presentation Safety Safety Functions Safety Functions can be basically divided in two main groups: ETS, Energize to Safety

More information

Inductive sensor BI1.5-EG08-Y1-H1341

Inductive sensor BI1.5-EG08-Y1-H1341 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

PSR-MS60. Safety relay for emergency stop, safety door and light grid monitoring. Data sheet. 1 Description

PSR-MS60. Safety relay for emergency stop, safety door and light grid monitoring. Data sheet. 1 Description SILCL IEC 62061 Safety relay for emergency stop, safety door and light grid monitoring Data sheet 106171_en_01 PHOENIX CONTACT 2015-05-19 1 Description Intended Use The PSR-MS60 safety relay can be used

More information

Datasheet - SLB 200-C04-1R

Datasheet - SLB 200-C04-1R 14.02.2013-17:06:30h Datasheet - SLB 200-C04-1R Safety light barriers / Safety monitoring modules to monitor safety light barriers / SLB 200-C Up to 2 light barrier pairs SLB 200 can be connected 1 safety

More information

LOGIC CONTROLLER INSTALLATION MANUAL NTR 756 B /E

LOGIC CONTROLLER INSTALLATION MANUAL NTR 756 B /E LOGIC CONTROLLER INSTALLATION MANUAL NTR 756 B /E Table of contents 1. INTRODUCTION...1 2. HARDWARE DESCRIPTION...2 3. INSTALLATION...6 4. CONNECTION...8 5. USER SAFETY AND PROTECTION OF THE EQUIPMENT...11

More information

Ultra Slim Relays 24

Ultra Slim Relays 24 Ultra Slim Relays 24 Technical Data... 1 Specifications.2 Model Number Structure - Relays...3 Model Number Selection...4 Accessories...5 Safety Precautions...6 Ultra Slim Relays WERNER`s embody the latest

More information

FL MC 2000T. Fiber optic converter for 10/100Base-Tx to single- or multi-mode fiberglass with SC-duplex and ST connections. Data sheet 3379_en_B

FL MC 2000T. Fiber optic converter for 10/100Base-Tx to single- or multi-mode fiberglass with SC-duplex and ST connections. Data sheet 3379_en_B Fiber optic converter for 10/100Base-Tx to single- or multi-mode fiberglass with SC-duplex and ST connections Data sheet 3379_en_B 1 Description PHOENIX CONTACT 2015-07-14 2 Features Media converters provide

More information

RM22TG. Product data sheet Characteristics. three-phase control relay Vac, 2 C/O. Main. Complementary. Network number of phases

RM22TG. Product data sheet Characteristics. three-phase control relay Vac, 2 C/O. Main. Complementary. Network number of phases Characteristics three-phase control relay 183 528Vac, 2 C/O Main Range of product Product or component type Relay type Network number of phases Relay name Relay monitored parameters Time delay type Switching

More information

Magnetic field sensor Magnetic-inductive Proximity Sensor BIM-M12E-Y1X

Magnetic field sensor Magnetic-inductive Proximity Sensor BIM-M12E-Y1X ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Threaded barrel, M12 x 1 Chrome-plated brass Rated operating distance 90 mm with DMR31-15-5 magnet DC 2-wire, nom.

More information

INSTRUCTION & SAFETY MANUAL

INSTRUCTION & SAFETY MANUAL D231E INSTRUCTION & SAFETY MANUAL SIL 2 Switch / Proximity Detector Repeater, Open Collector put DINRail and Termination Board, Model D231E D231E SIL 2 Switch/Proximity Detector Repeater, O.C. put G.M.

More information

DESIGO RX Individual room controllers. for fan-coil systems, chilled ceilings and radiators, with LONMARK-compatible bus communications

DESIGO RX Individual room controllers. for fan-coil systems, chilled ceilings and radiators, with LONMARK-compatible bus communications 3 834 DESIO RX Individual room controllers for fan-coil systems, chilled ceilings and radiators, with MARK-compatible bus communications RXC20.1 RXC21.1 The RXC20.1 and RXC21.1 controllers are used for

More information

Safety Instructions WARNING Follow carefully this safety and installation instructions. Improper work may lead to serious harmful for your health and also may damage seriously the IntesisBox and/or any

More information

MINI MCR-SL-PT100-UI(-SP)(-NC)

MINI MCR-SL-PT100-UI(-SP)(-NC) Configurable Temperature Transducer for PT100 Data Sheet 04/2005 Functions MINI MCR-SL-PT100-UI(-SP)(-NC) is a configurable 3-way isolated temperature measuring transducer. It is suitable for the connection

More information

Inductive sensor BI1.5-EG08-Y1-H1341

Inductive sensor BI1.5-EG08-Y1-H1341 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

TM7BDM16A expansion block - TM7 - IP67-16 DI/DO - 24V DC A - M12 connector

TM7BDM16A expansion block - TM7 - IP67-16 DI/DO - 24V DC A - M12 connector Characteristics expansion block - TM7 - IP67-16 DI/DO - 24V DC - 0.5 A - M12 connector Product availability : Non-Stock - Not normally stocked in distribution facility Price* : 753.00 USD Main Range of

More information

PRODUCT SPECIFICATION. PC Board Relays. Series.

PRODUCT SPECIFICATION. PC Board Relays. Series. PRODUCT SPECIFICATION PC Board Relays 26 Series www.wernerelektrik.com Technical Data... Specifications...2 Model Number Structure - Relays...3 Model Number Selection...4 Dimensions... 5-6 Accessories...7

More information

RM35TF. Main. Product or component type. Product specific application. Relay monitored parameters 250 V AC 5 A AC

RM35TF. Main. Product or component type. Product specific application. Relay monitored parameters 250 V AC 5 A AC Characteristics multifunction phase control relay RM35-T - range 194..528 V AC Complementary Reset time Maximum switching voltage Minimum switching current Maximum switching current [Us] rated supply voltage

More information

PSR-PC50. SIL 3 coupling relay for safety-related switch on. Data sheet. 1 Description

PSR-PC50. SIL 3 coupling relay for safety-related switch on. Data sheet. 1 Description SIL 3 coupling relay for safety-related switch on Data sheet 105818_en_01 PHOENIX CONTACT 2014-08-18 1 Description The PSR-PC50 SIL coupling relay can be used for power adaptation and electrical isolation

More information

CPCI-PS24 24V-Power Supply

CPCI-PS24 24V-Power Supply 24V-Power Supply Hardware Manual to Product I.2301.21 esd electronic system design gmbh Vahrenwalder Str. 207 30165 Hannover Germany http://www.esd.eu Phone: +49 (0) 511 3 72 98-0 Fax: +49 (0) 511 3 72

More information

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at Safety Instructions WARNING Follow carefully this safety and installation instructions. Improper work may lead to serious harmful for your health and also may damage seriously the IntesisBox and/or any

More information

Inductive sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933

Inductive sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933 ATEX category II 2 G, Ex zone 1 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

SPST-NO SPDT DPST-NO DPDT

SPST-NO SPDT DPST-NO DPDT Next-generation PCB Relay Available in Various Models ROHS compliant. High sensitivity: (250mW) and high capacity (16A) models available Low profile: 15.7 mm max. in height. Conforms to EN 61810-1, UL508

More information

RM17TG. Main. Product or component type. Product specific application. Relay monitored parameters. Switching capacity in VA 250 V AC

RM17TG. Main. Product or component type. Product specific application. Relay monitored parameters. Switching capacity in VA 250 V AC Characteristics phase control relay RM17-T - range 183..484 V AC Complementary Maximum switching voltage Minimum switching current [Us] rated supply voltage Supply voltage limits Control circuit voltage

More information

MINI MCR-SL-PT100-UI-200

MINI MCR-SL-PT100-UI-200 Configurable temperature transducer for PT00 INTERFACE Data sheet 078_en_0 PHOENIX CONTACT 00-0-5 Description The MINI MCR-SL-PT00-UI-00... is a configurable -way isolated temperature transducer. It is

More information

SALES NUMBER NUMBER OF BEAMS PROTECTIVE HEIGHT

SALES NUMBER NUMBER OF BEAMS PROTECTIVE HEIGHT SECTION 21 182 Safety Light Curtains Type: SLC-F Finger (14mm) FEATURES: Resolution: 14mm Protective height: 160mm to 1040mm Type 4 according to IEC61496-1 and -2 ORDERING INFORMATION: SALES OF BEAMS PROTECTIVE

More information

GS202 Encoder Switch

GS202 Encoder Switch GS202 Encoder Switch 20:2 encoder switch 20 encoder inputs (TTL / RS422 standard) Input signals A, /A, B, /B, Z, /Z on each encoder input 2 x 6 control inputs (HTL / PNP) 2 encoder outputs (TTL / RS422

More information

02/11/2015

02/11/2015 DIN Rail Mount 35 mm HSV Part number 84874320 Control of overspeed, underspeed, operating rate, stopping Measurement via discrete sensors - 3-wire PNP or NPN, Namur, voltage 0-30V or volt-free contact

More information

PSS SIL3 Power Supply System PSS1250, 24Vdc, A, Zone 2/Div Rack for up to 6 modules PSM1250

PSS SIL3 Power Supply System PSS1250, 24Vdc, A, Zone 2/Div Rack for up to 6 modules PSM1250 Characteristics: PSS 1250 General Description: The Power Supply System type PSS1250 is an anodized aluminum 19 Rack unit (4U high) suitable to accept up to 6 plugin Power Supply Modules type and 1 Overview

More information

MINI MCR-SL-PT100-UI. Active resistance thermometer measuring transducer. Data sheet. 1 Description

MINI MCR-SL-PT100-UI. Active resistance thermometer measuring transducer. Data sheet. 1 Description Active resistance thermometer measuring transducer Data sheet 099_en_06 PHOENIX CONTACT 0-0- Description The 6. mm wide MINI MCR-SL-PT00-UI-... is a configurable, -way isolated temperature measuring transducer.

More information

Faults on the system Proximity switch connection technology:

Faults on the system Proximity switch connection technology: Speed monitor for connection to a base unit from the PNOZmulti modular safety system Approvals Unit features Monitoring of 2 independent axes Connection of 2 incremental encoders or 4 proximity switches

More information

ETD-BL-1T-OFF-CC- 10S

ETD-BL-1T-OFF-CC- 10S Timer relay with off delay (with control contact) and adjustable time Data sheet 103617_en_03 1 Description PHOENIX CONTACT - 2013-09-16 Features Compact timer relay in 6.2 mm housing for controlling time

More information

Switched Mode Power Supply Operating manual PAP800

Switched Mode Power Supply Operating manual PAP800 Features: Switched mode power supply Wide output 0 144Vdc Analog control by an external 0 5Vdc Power failure alarm output Master-slave connection Powerfinn PAP series is a high power, lightweight, advanced

More information

TM7BDM8B. Main. Enclosure material. Input/output number 8 Input/output number of splitter box

TM7BDM8B. Main. Enclosure material. Input/output number 8 Input/output number of splitter box Product datasheet Characteristics TM7BDM8B Main Range of product Product or component type Range compatibility Enclosure material Bus type System Voltage Input/output number 8 Input/output number of splitter

More information

RM4TR31 three-phase network control relay RM4-T - range V

RM4TR31 three-phase network control relay RM4-T - range V Characteristics three-phase network control relay RM4-T - range 160..220 V Complementary [Us] rated supply voltage Control threshold undervoltage Control threshold overvoltage Output contacts Main Range

More information

Inductive sensor BI5-EM18-Y1X-H1141

Inductive sensor BI5-EM18-Y1X-H1141 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

Article no. BWU2045: AS-i Safety Relay Output Module with Diagnostic Slave and 1 EDM Input 1.23 NC

Article no. BWU2045: AS-i Safety Relay Output Module with Diagnostic Slave and 1 EDM Input 1.23 NC Safety + standard I/O in one module AS-i Safety relay output with galvanically isolated contact sets, approved up to 230 V IEC 61508 SIL 3, EN ISO 13849-1/PLe Kat 4, EN 62061 SIL 3 Protection category

More information

IB IL 24/48 DOR 2/W-XC-PAC

IB IL 24/48 DOR 2/W-XC-PAC Inline digital output terminal, version for extreme conditions, 2 relay PDTs Data sheet 8463_en_01 PHOENIX CONTACT 2015-08-12 1 Description The terminal is designed for use within an Inline station. It

More information

Conductive Level Controller

Conductive Level Controller Conductive Level Controller 61F-D21T-V1 Ideal for level control for industrial facilities and equipment. Outputs can be set to self-hold at ON or OFF using self-holding circuits. Sensitivity adjustment

More information

Safety. Detection. Control. MAGNUS RFID ENG - REV

Safety. Detection. Control. MAGNUS RFID ENG - REV 03 2017 1 Next generation RFID safety sensor 03 2017 2 03 2017 3 Next generation sensors for machine safety RFID safety sensors PL e, SIL 3 The application of Magnus RFID sensors can be extremely wide

More information