1 Instruction manual of the controller unit PCS ph-redox-chlorine-temp PCS ph-oxygen-temp PCS ph-redox-temp

2 SPIS TREŚCI GENERAL INFORMATIONS... 3 Main Functions... 3 Unit Specification... 3 Unit Dimensions INSTALATION... 5 Wall Mounting... 5 Instalation In Circulation Systemss... 5 Internet Connection Requirement OPERATIONS... 5 Readings Menu... 6 ph Menu... 9 Chlorine Menu Redox Menu Temperature Menu Main Pump Menu Reports Menu Configuration Menu INSTRUCTION MANUAL FOR PCS ph/oxygen/temp CONTROLLER INSTRUCTION MANUAL FOR PCS ph/redox/temp CONTROLLER Redox Menu

3 GENERAL INFORMATIONS The PCS controller is an automated water control system based on microprocessor. Easy to read menu thanks to clear LCD display. All options and settings are easily accessible through an logically structured, intuitive menu system and can be navigated using a touch screen display. All probes and sensors are connected to one central control unit which gives us the ability to monitor all parameters. In addition there are programmable alarms available that can be set in case of any malfunctions or hardware damage. MAIN FUNCTIONS ph Control and dosing REDOX Control Chlorine Control and dosing Temperature monitoring Measuring cell flow control Managing working time of the filtration pump Constant Internet connection Automatic saving of data history Additional functions Water level control with level sensors and solenoid valve Chemical substances containers level control Temperature control Wireless internet connection UNIT SPECIFICATION Display LCD 7 WITH TOUCH SCREEN INTERFACE ORP electrode mv WITH Ag/AgCl CORE AND Pt TIP ph electrode 0-14 with basic correction, built from Ag/AgCl core with silicon oxide covered glass tip Chlorine electrode 0-10mg/l Cl2 depolarization galvanic cell with swirling glass spheres with platinum(pt) and copper(cu) electrodes Temperature -10 do 85 C, ability to control the electric heating element, CO exchanger and solar system Steering method manual and automatic Memory automatic parameter history saving Remote control unit control and archival data access through internet service Dimensions 320x 522x129 mm Main power supply connection 230V AC Weight 12kg Warranty 2 years for electronic components 3

4 UNIT DIMENSIONS 4

5 INSTALATION WALL MOUNTING PCS CONTROLLER has to be securely mounted on the wall. The area has to be clean and dry to guarantee correct functioning of the controller. The controller should be mounted close to the water inlet and shielded from heat and sun. The controller should be mounted in safe place: - easily accessible to personnel - if possible, in separate well ventilated room, away from corrosive chemical solutions. - in safe distance from mains transformers, pump engines and high voltage lines - guarded from unauthorized access. INSTALATION IN CIRCULATION SYSTEMS All installation work has to be done carefully according to all health and safety rules. The monitoring-adjusting station and all others electric devices like electric heating or circulation pump has to be separated from the main electric circuit. All installation instructions of electrical devices have to be upheld. INTERNET CONNECTION REQUIREMENT In order for the unit to be remotely monitored and controlled it has to be connected to the internet network. The internet provider or internal network configuration is not important. There is an additional option of wireless Internet connection under condition that there is a Three phase electrical socket where the controller is going to be installed. The alternative is a radio Internet connection but only if the connection signal is very strong In the room where the controller is going to be installed. OPERATIONS the LCD Monitor is a high resolution touch screen display unit. The touch screen is very sensitive so only a light touch is needed to operate. The screen is quite resilient and robust but the user has to make sure not to scratch it and keep it away from liquids(like chlorine, ph+/- etc.) The display can be cleaned with gentle cleaning agent and soft cloth and then rinsed using clean damp cloth. The display is divided In to two parts: On the left side there is menu with selection of options: readings, ph, Chlorine, Redox Temperature, Main pump, Reports, Configuration The right side displays information about set parameters with adjustment options Next we are going to explain all the menu options in chronologic order. 5

6 READINGS MENU This menu includes information about current controller work and shows water parameters in the pool. Figure 1 1. This section displays current parameters like ph, Chlorine, Redox, Temperature and flow status. When the minimal or maximal level is exceeded the field lights up in red. 2. Squares indicating dosing of ph and Chlorine - gray color no dosing - green color dosing active When squares 2 are green counters displaying time in seconds are showing. 3. Counter indicating when the measurements are taken used to calculate the dosing times. In default it s set to 100 seconds (1:40) after that time the controller checks the chemical parameters of the water, analyze them and sets the duration of dosing of the chemical components. The counting process runs in cycles if: a. Filtration pump is running b. There are no alarms active c. The dosing delay time is not programmed d. ph and Chlorine dosing set to automatic 4. Pump working status indication, possible working modes (manual, automatic) a. Green color indicates that pump is working b. Grey color, the pump is off Detailed description of turning on and switching the pump can be found in MAIN PUMP MENU 5. These buttons allow switching between automatic and manual ph dosing mode green color indicates chosen mode. 6. These buttons allow switching between automatic and manual Chlorine dosing mode green color indicates chosen mode. 6

7 Changing the dosing mode to manual (pressing the Manual button) for both ph and Chlorine causes two additional buttons to show up on screen which can be seen on Figure2 as 5a and 6a allowing manual dosing to be turn on. 7. Expansion tank level. 8. Current time. Figure 2 7

8 After pressing the 5a button Figure2 the screen changes to: Figure 3 The ph dosing status button Has turned Green and ph dosing time counter is running on picture it Has value 6 sec. This is analogical for button 7a concerning chlorine dosing. These Buttons are used for Turing manual dosing on as well as off. 8

9 PH MENU Allows to enter the ph set point of water In the pool, the maximal and minimal value of ph when the alarm is going to be activated. It also Allows to calibrate the ph probe. In addition it also displays the information about the aggregate ph dosing time from the time when the device is switched on or the counter is reset. Figure 4 1. Shows current ph value of the water in pool 2. Fields showing set values: - set point optimal pool water ph value - high alarm value when reached or exceeded the alarm will appear - low alarm value when reached or exceeded the alarm will appear 3. 3a allows the set point to be changed. 3b allows the high alarm value to be changed. 3c allows the low alarm value to be changed. 4. Calibration button (Figure4) after pressing which the ph calibration is possible calibration screen Figure6 5. Button (Figure4) cancels all changes to ph parameters and returns to readings screen 6. Button (Figure4) confirms the changes to ph parameters and returns to readings screen 9

10 After pressing the 3a, 3b or 3c button a window should pop up that allows to type in wanted values, as on Figure5 below Figure 5 10

11 Figure 6 1. Field shows current ph value 2. Button allows editing the real ph value read from buffer solution or photometer 3. Button cancels the calibration process. 4. Button confirms the calibration 11

12 CHLORINE MENU Allows to edit the chlorine set point of water in pool, as well as the high and low alarm value when the alarm is going to start, it also allows to calibrate the chlorine probe. In addition it also displays the information about the aggregate chlorine dosing time from the time when the device is switched on or the counter is reset. Figure 7 1. Shows current chlorine value of the water in pool 2. Fields showing set values: - set point optimal pool water chlorine value - high alarm value when reached or exceeded the alarm will appear - low alarm value when reached or exceeded the alarm will appear 3. 3a allows the set point to be changed. 3b allows the high alarm value to be changed. 3c allows the low alarm value to be changed. After pressing the 3a, 3b or 3c button a window should pop up that allows to type in wanted values, as on picture below 4. Calibration button after pressing which the chlorine probe calibration is possible calibration screen (Figure8) 5. Button cancels all changes to chlorine parameters and returns to readings screen 6. Button confirms the changes to chlorine parameters and returns to readings screen 12

13 Figure 8 1. Field shows current chlorine value 2. Button allows typing in the real chlorine value read from photometer analogical to ph value 3. Button cancels the calibration process 4. Button confirms the calibration 13

14 REDOX MENU Allows to type in the REDOX maximal and minimal value when the alarm is going to start, it also allows to calibrate the REDOX probe. Figure 9 1. Field shows the current REDOX 2. Field shows the top and bottom alarm value 3. Buttons 3a and 3b allow to change the top button 3a and bottom button 3b alarm values as in other values 4. Calibration button after pressing which the REDOX probe calibration is possible calibration screen Figure10 below. 14

15 Figure Field shows current REDOX value 2. Button allows typing in the real REDOX value read from benchmark buffer for REDOX 3. Button cancels the calibration process. 4. Button confirms the calibration 15

16 TEMPERATURE MENU Allows to set the water temperaturee as well as calibrate the temperature sensor Figure Field shows the current water temperature 2. Field indicates the wanted temperature of water in the pool (the value can be changed by pressing the button 3) 3. Button allows to enter temperature value 4. Button after pressing whichh the temperature sensor calibration is possible calibration screen (Figure12) 5. Button cancels all changes to temperature parameters and returns to readings screen 6. Button confirms the changes to temperature parameters and returns to readings screen 16

17 Figure Field shows current temperature value 2. Button allows typing in the real temperature value read from an external accurate thermometer 3. Button cancels the calibration process. 4. Button confirms the calibration 17

18 MAIN PUMP MENU Allows to set the pump working periods in automatic mode, also turning it off or on in manual mode. Figure This button switches on the manual mode 2. This button switches on the automatic mode 3. Yellow frame indicates the pump working mode (manual or automatic) 4. Buttons allowing to set the pump work time periods in automatic mode for each day of the week 5. Button allowing to copy the pump work time periods set on Monday to all other days of the week 6. Fields displaying the pump work time periods in automatic mode on each day of the week 7. Button confirming pump settings 18

19 Manual mode press button1 Figure14 for manual mode switches the pump in to manual mode following options shows up on screen Figure Button the yellow frame indicates that manual mode is on 2. Buttons allows switching the main pump on or off, yellow marker indicates which option is active 19

20 Automatic mode press button2 Figure14 for automatic mode, switches the pump in to automatic mode following options shows up on screen Figure 15 button4 allows to enter the pump work time periods on given day of the week, see Figure16 Figure 16 20

21 1. Field1 Figure16 displays the work period starting time in HH:MM format, editing is done using button 1a Figure16 after pressing which following screen shows up Figure Field Figure16 displays the work period ending time, editing is done using button 2a Figure17 analogical to starting time 3. Button Figure16 allows cancelling entering for each periods 4. Button Figure16 allows editing next period press to activate analogical buttons for the next period 21

22 Figure 18 Press the button4 Figure16 again to activate the third period Figure 19 Button5 Figure16 confirms entered below settings and returns to the main pump menu, which now should look as 22

23 Figure 20 Now by using buttons 4 for each day it is possible to enter each pump work time periods or by pressing button 5 to copy identical settings from Monday to all others day of the week. If we would like to change pump work time periods on Saturdays then all we need to do is press button 4 Saturday and change the settings as described above, e.g. Period 2 is set to 15:00 16:30 Figure 21 23

24 Caution! Every settings change in automatic mode has to be confirmed by pressing the confirm button. In other case entered settings will not be saved. REPORTS MENU Allows to view archival data and pool work analysis. We can check what alarms have been triggered, if all set parameters have been reached and in what time. Figure Alarms button displays alarms data date (Day and time), alarm type and value. 2. Archival Data button displays data about pool water parameters ph Reading, chlorine Reading, redox and temperature. 3. Event Viewer displays In formations about events that took place date (Day and time), type of event e.g. Pump stopping, pump switching to manual mode, alarm reset, All events that took place while the device was running. Bellow there are some examples shown after pressing each button 24

25 Button 1 Alarms Figure22 after pressing which following screen will show up sorted by date starting from the latest Figure 23 column 1 displays date and time column 2 displays alarm type column 3 alarm value Last 100 alarms can be viewed on screen. 25

26 Button 2 Archival Data Figure22 screen looks as follows Figure 24 Button 4 Event Viewer Figure22 screen looks as follows Figure 25 26

27 CONFIGURATION MENU Allows to change the device configuration according to pool specification. This menu should be used Only by a qualified personnel. Figure 26 Menu includes 5 Buttons see Figure26 above we are going to explain each one In chronological order starting form Administration. Administration Button Figure26 after pressing which the screen will show up asking for password 27

28 After entering the password following screen will show: Figure 27 After pressing Buttons 1-6 we will have the opportunity to enter or change set value Button 8 cancels entered changes. Button 9 confirms entered changes. Button 7 causes switching to next screen allowing to Edit different parameters Figure 28 28

29 Buttons work analogical to Buttons 1-6 from Figure30 Button 14 switches on or off the chemicals tanks level Reading Button 15 main pump control ticked box means on Button 16 switches on or off the current transducers control option Button 17 returns to previous screen Button 18 exit without saving Button 19 exit and save changes. Default configuration button Figure26 returns to default settings Figure button displays informationn about default settings Figure30 2. button causes ph, Redox and temperature settings to return to default values and exits to configuration menu 29

30 Figure 30 Service Information button Figure26 displays Basic device information needed for service. 30

31 INSTRUCTION MANUAL FOR PCS PH/OXYGEN/TEMP CONTROLLER When servicing PCS ph-oxygen controller the full PCS ph Redox-Cl instruction manual should be used. The differences are explained below. On the main screen Readings the OXYGEN field ( field 2. ) based on calculations shows the daily dose in mg per Day, considering the number of days chosen for weekly dosage. Shown above is the active oxygen dosage configuration screen, each field is described below: 31

32 Step 1: 1. enter the pool capacity In m enter the weekly dosage In ml/ 1m 3. e.g.: according to instructions placed on Bayrosoft containers the weekly dosage should be 0,5L to 10m 3 of water field B is filled by default according to Bayrosoft instruction. In case of using deferent manufacturer product the field Has to be modified accordingly. 3. shows efficiency the dosing pumps originally installed In PCS ph-tlen controller. In case when different pumps are used the settings should be changed accordingly. 4. after All above Fields are complete Press the calculate button, the chemical agent dosage will be calculated In minutes per week. Pressing the calculate button does not confirm configuration changes, it is only the first step needed to calculate the active oxygen dosage. Step 2: 5. used for choosing days of the week when the dosing takes place. By pressing the days buttons we can mark or unmark each day. Buttons that are greyed out- inactive (see picture above Thursday, Saturday, Sunday) indicate days when the main filtration pump is switched off. Please read the filtration pump configuration In attached instruction. Inactive buttons eliminatee the possibility of setting the dosing on day when the filtration pump is switched off. After choosing the dosing days the weekly dosage is divided between the chosen days in equal measures. e.g.: pool capacity 20m 3 weekly dosage 50ml/m 3 calculated dosage 20 x 50ml = 1000ml = 1 liter per week When we choose 3 days for dosing, then each day the device will dose 333ml When we choose 4 days for dosing, then each day the controller will dose 250ml. 6. the OK. button confirms All changes entered on the oxygen panel. After pressing the OK. button the controller will calculate the daily dosage, then show the main controller page ( Readings ) and update the daily dose. Controller will also calculate the period of time the dosing pumps have to work to administer given dose to the pool. 32

33 INSTRUCTION MANUAL FOR PCS PH/REDOX/TEMP CONTROLLER When servicing PCS ph/redox/temp controller the full PCS ph Redox-Cl instruction manual should be used. The differences are explained below. On the main screen Readings there is a REDOX button which activates chlorine dosing to the pool, there is no free chlorine reading. REDOX MENU Allows to type in the REDOX set point, maximal and minimal value when the alarm is going to start, it also allows to calibrate the REDOX probe. ( see page 14.) 33

34 34

35 35

36 36

Control and automatic dosing

Control and automatic dosing Control and automatic dosing For public and residential pools Control Basic and Control Basic Plus Control Basic Next Optima and Optima Next dosing pumps Panels for the galvanic and amperometric control

More information

1 PoolManager 5 Software Releases Overview

1 PoolManager 5 Software Releases Overview PoolManager 5 - Software Releases Overview - Status as at 20.08.2013 1 1 PoolManager 5 Software Releases Overview Advice: The current installed software version on a PoolManager controller can be displayed

More information

PM5 Software Versions Version EN

PM5 Software Versions Version EN PM5 Software Versions Version 7.4.2 EN Overview of all Software Versions Analyt / PoolManager / PoolManager PRO (5 th generation PoolManager 5 / PM5 ) Valid for Analyt PoolManager PoolManager PRO 1 Overview

More information

Please enter the identity code of your device here!

Please enter the identity code of your device here! Operating Instructions DULCOMETER D2C Part 2: Adjustment and Operation, Measured Variables ph/orp ProMinent D2C2-001-pH/ORP-GB ph/orp 7.20 ph 750 mv DULCOMETER STOP START ph/orp 7.20 ph 750 mv DULCOMETER

More information

BL121 Pool & Spa Controller. ph/orp Swimming Pool Controller with Built-In Chemical Feed Pumps

BL121 Pool & Spa Controller. ph/orp Swimming Pool Controller with Built-In Chemical Feed Pumps BL121 Pool & Spa Controller ph/orp Swimming Pool Controller with Built-In Chemical Feed Pumps Introduction The BL121 is an all-in-one solution for automatic control of ph and chlorine levels in swimming

More information

M-Module Please enter the identcode of your module!

M-Module Please enter the identcode of your module! Supplementary Instructions DULCOMARIN II, M Module (Measurement module for, redox/orp, temperature) DXMaM: Operation M-Module 7.12 Cover page_dxca DXMa Please enter the identcode of your module! This Operating

More information

GENERAL SAFETY GUIDELINES

GENERAL SAFETY GUIDELINES This manual contains important safety information about installation and use of this equipment. Ignoring this information could result in injuries or damages. It is strictly forbidden to use this equipment

More information

HydroGuard 4 to 20 ma Output Module. For use with HydroGuard Water Quality Monitor and Controller

HydroGuard 4 to 20 ma Output Module. For use with HydroGuard Water Quality Monitor and Controller HydroGuard 4 to 20 ma Output Module For use with HydroGuard Water Quality Monitor and Controller Technician's Manual Installation, Operation, and Maintenance Guide Chapter 1: Preface... 3 1.1 Intended

More information

JUMO ecotrans ph 03 Microprocessor transmitter/ switching device for ph/redox voltage and temperature

JUMO ecotrans ph 03 Microprocessor transmitter/ switching device for ph/redox voltage and temperature Page 1/7 JUMO ecotrans 03 Microprocessor transmitter/ switching device for /Redox voltage and temperature with a 2-line LCD for mounting on a 35 mm DIN rail Brief description Depending on the configuration,

More information

LDCL DIGITAL CONTROLLER OPERATING MANUAL

LDCL DIGITAL CONTROLLER OPERATING MANUAL This manual contains important safety informations about installation and use of this equipment. Ignoring this informations could result in injuries or damages. It is strictly forbidden to use this equipment

More information

HydroGuard Expert Pool Manual

HydroGuard Expert Pool Manual HydroGuard Expert Pool Manual Draft 09 May 2006 Swimming Pool Quality Communication and Monitoring Preface Intended Use This manual is for qualified and trained pool service technicians who will install

More information

Nitrite photometer. mono. Operating Instructions

Nitrite photometer. mono. Operating Instructions Nitrite photometer mono Operating Instructions Contents 1. Important Safety Information 1.1 Notes and symbols used in these instructions 1.2 Intended use 1.3 Staff qualifications 1.4 Warning notices in

More information

Please enter the identity code of your device here!

Please enter the identity code of your device here! Operating Instructions DULCOMETER D2C Part 2: Adjustment and Operation, Measured Variables ph/ ProMinent D2C2-001-pH/-GB ph/cl 2 7.00 ph 0.45 ppm DULCOMETER STOP START ph/cl 2 7.00 ph 0.45 ppm DULCOMETER

More information

WATERGUARD WG-602 FREE CHLORINE ANALYZER. User Manual

WATERGUARD WG-602 FREE CHLORINE ANALYZER. User Manual WATERGUARD WG-602 FREE CHLORINE ANALYZER User Manual V5.15US January 2018 1 Table of Contents 1 General Safety Precautions... 4 2 Preface... 5 2.1 Intended Use... 5 2.2 Safety Precautions... 5 3 Overview...

More information

Neon pr. ph/ ORP measurement. Applications. Description

Neon pr. ph/ ORP measurement. Applications. Description Easy handling by graphical menue Fitting for your application by modular setup Simple firmware update and configuration using SD-card Applications Process Water Drinking Water / Beverages Waste Water Treatment

More information

Electronic Dosing Systems Ltd

Electronic Dosing Systems Ltd Electronic Dosing Systems Ltd Telephone 01299 825 656 Email info@electronicdosingsystems.co.uk Cooling Tower Systems Touch Series Controllers TOUCH series multifunction parameter systems with touch screen

More information

Microprocessor ph/orp Controller

Microprocessor ph/orp Controller PC3030A/PC-3050 Microprocessor ph/orp Controller Operating Manual CONTENTS 1 Specifications... 2 Assembly and installation... 2.1 Precautions for installation.. 2.2 Install the controller on the wall mount

More information

USER MANUAL REFEREE WATCH AR022

USER MANUAL REFEREE WATCH AR022 USER MANUAL REFEREE WATCH AR022 INTRODUCTION Congratulations on your new referee watch! This watch is a user-friendly tool to keep track of your time in multiple ways in various situations. To develop

More information

Resolution 1 F (1 C) single point; degrees C or Calibration single or dual point Calibration F

Resolution 1 F (1 C) single point; degrees C or Calibration single or dual point Calibration F RMS Rainwater Harvesting Series 100 Controller Specifications Measurement Performance Contacting Conductivity ph Range 0-10,000 µs/cm Range -2 to 16 ph units Resolution 1 µs/cm Resolution 0.01 ph units

More information

Introduction: Features:

Introduction: Features: Index Features:... 3 Specifications:... 4 Accessories:... 5 Functions of Keyboard:... 7 Preparation:... 8 ... 8 ... 8 Calibration:... 8 ... 8 ... 9 ...

More information

Control instruments GUARDIAN 2 - GUARDIAN 3

Control instruments GUARDIAN 2 - GUARDIAN 3 Control instruments GUARDIAN 2 - GUARDIAN 3 Table of contents 1. General informations... 3 2. Technical data... 3 3. GUARDIAN 2 connection diagram...4 3.1. TTL connection diagram for GUARDIAN 2 instrument...5

More information

Manual. Dimmer DMD-12-2

Manual. Dimmer DMD-12-2 Manual Dimmer DMD-12-2 Table of contents 1. Safety instructions... 3 1.1. For safe and efficient operation... 3 2. Overview... 5 2.1. Front view... 5 2.2. Rear view... 6 2.3. Termination... 6 3. Operating

More information

LCD LCDS LCDRI CONTROLLER OPERATING MANUAL

LCD LCDS LCDRI CONTROLLER OPERATING MANUAL This manual contains important safety information about installation and use of this equipment. Ignoring this information could result in injuries or damages. It is strictly forbidden to use this equipment

More information

SYCLOPE INDIG O controller for semi publics swimming pools (Part 2) Programming instructions. References : CEN0000, CEN0001 and CEN0005 Rev : 3

SYCLOPE INDIG O controller for semi publics swimming pools (Part 2) Programming instructions. References : CEN0000, CEN0001 and CEN0005 Rev : 3 SYCLOPE INDIG O controller for semi publics swimming pools (Part 2) Programming instructions References : CEN0000, CEN0001 and CEN0005 Rev : 3 Generals information Page 2/28 Part 1 : Installation and starting

More information

16 pools with just one central unit with ProMinent The new swimming pool controller DULCOMARIN II

16 pools with just one central unit with ProMinent The new swimming pool controller DULCOMARIN II 16 pools with just one central unit with ProMinent The new swimming pool controller DULCOMARIN II Printed in Germany / PT DC 002 10/04 GB The DULCOMARIN II and the DULCO -Net technology are revolutionising

More information

Stage Fog Machine User Manual

Stage Fog Machine User Manual M-4 Stage Fog Machine User Manual English 2014 Antari Lighting and Effects Ltd. 1 2 Safety Information Please read the following safety information carefully before operating the machine. Information includes

More information

INSTRUCTION MANUAL HBPH DIFFERENTIAL 2-WIRE (4-20 ma) ph Sensor

INSTRUCTION MANUAL HBPH DIFFERENTIAL 2-WIRE (4-20 ma) ph Sensor INSTRUCTION MANUAL HBPH DIFFERENTIAL 2-WIRE (4-20 ma) ph Sensor TABLE OF CONTENTS 1. GENERAL INFORMATION 2 2. SPECIFICATIONS 2 3. INSTALLATION 3 3.1. General Instructions 3 3.2. HBPH 4-20 ma Sensor 3 4.

More information

ph, ORP, and TDS ORP Continuous Monitor OPERATING INSTRUCTIONS 8. Warranty 9. Return of Goods

ph, ORP, and TDS ORP Continuous Monitor OPERATING INSTRUCTIONS 8. Warranty 9. Return of Goods ENTER 8. Warranty Oakton Instruments warrants this product to be free from significant deviations in material and workmanship for a period of three year from the date of purchase (excludes electrode).

More information

PoolManager Version 2.5

PoolManager Version 2.5 PoolManager Version 2.5 GB User Manual for the Measuring, Control, and Dosing System for Swimming Pools PoolManager Chlorine PoolManager Bromine PoolManager Oxygen PoolManager PRO Content Content Part

More information

MTD75 Comprehensive cooling tower controller with all the functions required for dosing and control of cooling water

MTD75 Comprehensive cooling tower controller with all the functions required for dosing and control of cooling water MTD75 Comprehensive cooling tower controller with all the functions required for dosing and control of cooling water Features Real time clock for accurate timed dosing Water meter input for volumetric/proportional

More information

Main Screen. Individual Alerts & Dosing Recommendations. Water Temperature. Menu Bar. Battery Level Signal Connection.

Main Screen. Individual Alerts & Dosing Recommendations. Water Temperature. Menu Bar. Battery Level Signal Connection. Main Screen Individual Alerts & Dosing Recommendations Water Temperature Menu Bar Setup/Status Tabs Reminders Area Battery Level Signal Connection No Connection Icon Last Data Packet Received Estimated

More information

Operating Instructions

Operating Instructions Operating Instructions DULCOMARIN II Pool Controller DXCa Part 2: Operation DXCa_Titel These operating instructions apply only in conjunction with the Operating Instructions DULCOMARIN II Pool Controller,

More information

Temperature control unit

Temperature control unit Temperature control unit 5739 18/19 Installation manual Part. U3582A - 12/08-01 PC Contents 1 - Introduction 5 1.1 - Warnings and tips 5 1.2 - Contents of package 5 2 - Description of the Control unit

More information

W-715 Fog Jet USER MANUAL English 2013 Antari Lighting and Effects Ltd.

W-715 Fog Jet USER MANUAL English 2013 Antari Lighting and Effects Ltd. W-715 Fog Jet USER MANUAL English 2013 Antari Lighting and Effects Ltd. 1 2 Safety Information Please read the following safety information carefully before operating the machine. Information includes

More information

MULTI-FUNCTION DISPLAYS A3416: 8 INCH / A3417: 13.3 INCH

MULTI-FUNCTION DISPLAYS A3416: 8 INCH / A3417: 13.3 INCH Multi-Function Displays (A3416 & A3417) - Overview, Configuration MULTI-FUNCTION DISPLAYS A3416: 8 INCH / A3417: 13.3 INCH The OctoPlex A3416/A3417, Multi-Function Displays allow for the users to control

More information

Robe X1 FT PRO USER MANUAL. Version: 1.1. ROBE Lighting s.r.o. Czech Republic

Robe X1 FT PRO USER MANUAL. Version: 1.1. ROBE Lighting s.r.o. Czech Republic Robe X1 FT PRO USER MANUAL Version: 1.1 ROBE Lighting s.r.o. Czech Republic www.robe.cz Robe X1 FT PRO Table of contents 1. Introduction... 4 2. Safety information... 4 3. Unpacking and Inspection...

More information

MULTIPOWER MANUAL. Designed and Manufactured by ITEC Tontechnik und Industrieelektronik GesmbH 8200 Laßnitzthal 300 Austria / Europe

MULTIPOWER MANUAL. Designed and Manufactured by ITEC Tontechnik und Industrieelektronik GesmbH 8200 Laßnitzthal 300 Austria / Europe MANUAL Designed and Manufactured by ITEC Tontechnik und Industrieelektronik GesmbH 8200 Laßnitzthal 300 Austria / Europe Dear Customer! The power output stages of the product line ITEC MULTIPOWER are well-known

More information

Device technology. Supply Bus voltage V DC. Current consumption via bus. Accuracy in the range 300 1,000 ppm 1,000 2,000 ppm 2,000 5,000 ppm

Device technology. Supply Bus voltage V DC. Current consumption via bus. Accuracy in the range 300 1,000 ppm 1,000 2,000 ppm 2,000 5,000 ppm 2 2.1 Air Quality Sensor LGS/A 1.1 The ABB i-bus KNX Air Quality Sensor 1.1 is a combined sensor for CO 2, temperature and humidity measurement (relative humidity). Three independent thresholds can be

More information

User's Guide. Online Meters. PH / ORP / TDS / Conductivity.

User's Guide. Online Meters. PH / ORP / TDS / Conductivity. User's Guide Online Meters PH / ORP / TDS / Conductivity www.rakiro.net Introduction Continuous monitoring of PH / ORP is commonly required in a wide variety of industries ranging from water, chemical,

More information

AirTouch 2 Zone Control System

AirTouch 2 Zone Control System AirTouch 2 Zone Control System User Manual www.polyaire.com.au 2016 Polyaire Pty Ltd Liability Please read the instructions before installing this Zonemaster Zoning Control System. Polyaire Pty Ltd does

More information

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016 Operating instructions AS-i SmartLine module AC3200 AC3201 80237876/00 06/2016 Contents 1 Preliminary note...3 1.1 Symbols used...3 1.2 Warnings used...3 2 Safety instructions...3 2.1 General...3 2.2 Target

More information

SD1. Differential Controller. Operating and Installation Instructions F2 72.3

SD1. Differential Controller. Operating and Installation Instructions F2 72.3 SD1 Differential Controller Operating and Installation Instructions F2 72.3 i Please follow the safety information and read these Instructions carefully before putting the system into operation. Safety

More information

4801P ph/orp controller

4801P ph/orp controller 4801P ph/orp controller Introduction: Thank you for choosing this ph/orp controller. This 1/16 DIN controller offers dual backlight LCD display, high accuracy, LED indicators, two control relays, and automatic

More information

Dimmer DPX terminal

Dimmer DPX terminal Manual Dimmer DPX-620-3 terminal Table of contents 1. Safety instructions... 3 1.1. FOR SAFE AND EFFICIENT OPERATION... 3 2. Overview... 5 2.1. Front view... 5 2.2. Rear view... 6 2.3. Wiring Diagram...

More information

BMR Operating Instructions

BMR Operating Instructions BMR Operating Instructions BMR Operating Instructions 1. BMR Introduction 2. Device Description 3. BMR Introduction 1. - 2 1. BMR Introduction 1. BMR Introduction... 2 1.1. General Information... 3 1.2.

More information

SOLARIMMERSION IV Advanced Installation Manual v1.9

SOLARIMMERSION IV Advanced Installation Manual v1.9 SOLARIMMERSION IV Advanced Installation Manual v1.9 1 Contents 1. Overview 2. Technical Specifications 3. Installation Mounting Electrical Installation Clamp Installation Wiring Diagrams 4. Installation

More information

INSTRUCTION MANUAL ORP-METER MODEL COR-01

INSTRUCTION MANUAL ORP-METER MODEL COR-01 INSTRUCTION MANUAL ORP-METER MODEL COR-01 EL-221, MIDC Electronic Zone, Mhape, Navi Mumbai-400701. Tel: 022-61944000 CHAPTER 1 INTRODUCTION CONTECH ORP meter measures ph and mv, can used for Oxidation

More information

Quick Start Installation and User Manual

Quick Start Installation and User Manual 1 Quick Start Installation and User Manual Contents 1. Overview 2. Technical Specifications 3. Installation Mounting Electrical Installation Clamp Installation Wiring Diagrams 4. Installation Settings

More information

INSTRUCTION MANUAL. ph/mv CONTROLLER/RECORDER

INSTRUCTION MANUAL. ph/mv CONTROLLER/RECORDER INSTRUCTION MANUAL ph/mv CONTROLLER/RECORDER LIMITED ONE YEAR WARRANTY Manufacturer warranties all instruments (excluding batteries, damage caused by batteries, probes, standards, buffers) against defects

More information

MXD70 SERIES. Instrumentation to meet your Process Requirements. Features.

MXD70 SERIES. Instrumentation to meet your Process Requirements. Features. MXD70 SERIES Instrumentation to meet your Process Requirements Features The innovative MXD70 series of process instruments brings a new dimension to analytical process measurements with the modular design

More information

T80 Universal Transmitter S80 Intelligent Sensors

T80 Universal Transmitter S80 Intelligent Sensors T80 Universal Transmitter S80 Intelligent Sensors Presented by: January 2012 ELECTRO-CHEMICAL DEVICES T80 Universal Transmitter One Transmitter for Multiple Measurements ph ORP Dissolved Oxygen All Specific

More information

Fully Automated Formalin Mixing and Dispensing Station

Fully Automated Formalin Mixing and Dispensing Station Fully Automated Formalin Mixing and Dispensing Station Type: AFMDS-100 Content 1 Warnings... 3 1.1 General Warnings... 3 1.2 Safety Instructions... 3 2 Overview... 3 3 Device Features... 5 4 Menu... 5

More information

Operation Manual MODEL 2TX. 2-wire Isolated ph/orp Transmitter

Operation Manual MODEL 2TX. 2-wire Isolated ph/orp Transmitter Operation Manual MODEL 2TX 2-wire Isolated ph/orp Transmitter 0 2TX CONTENTS INITIAL INSPECTION.....2 INTRODUCTION......2 ASSEMBLY...3 PREPARATION....4 CONNECTING THE ELECTRODE...4 CONNECTING THE TEMPERATURE

More information

BIC 100 BERMAD Irrigation Control System

BIC 100 BERMAD Irrigation Control System BIC 100 BERMAD Irrigation Control System BIC 100 PROGRAMA 1234567 1 2 1 2 13:47 H:M MV M Operation Manual BERMAD Water Control Solutions Contents Page 1. General Description 03 2. Normal Mode Defining

More information

Advidia A-15 & A-35 Installation Manual

Advidia A-15 & A-35 Installation Manual Advidia A-15 & A-35 Installation Manual Thank you for purchasing our product. If there are any questions, or requests, please do not hesitate to contact the dealer. This manual may contain inaccuracies

More information

Please carefully read these operating instructions before use! Do not discard! Damages due to improper operation will invalidate the warranty!

Please carefully read these operating instructions before use! Do not discard! Damages due to improper operation will invalidate the warranty! Preliminary Operating Instructions DULCOMARIN II Pool Controller DXCa Part 2: Operation DXCa_Titel These operating instructions apply only in conjunction with the Operating Instructions DULCOMARIN II Pool

More information

User Manual Digi-Sense 12-Channel Benchtop Data Logging Thermocouple Thermometer

User Manual Digi-Sense 12-Channel Benchtop Data Logging Thermocouple Thermometer User Manual Digi-Sense 12-Channel Benchtop Data Logging Thermocouple Thermometer Model: 92000-01 THE STANDARD IN PRECISION MEASUREMENT Table of Contents Introduction... 3 Unpacking... 3 Initial Setup...3

More information

Operating Instructions COROS OP7 GB

Operating Instructions COROS OP7 GB Operating Instructions COROS OP7 GB Table of Contents Page 1 Display OP7 - Main Functions... 3 1.1 Description of Softkey, Function and System Buttons... 3 1.2 Displaying Text Variables... 5 2 Switching

More information

User Guide IM/AX4PH Rev. N. AX416, AX436, AX460, AX466 & AX468 Single and dual input analyzers for ph/redox (ORP)

User Guide IM/AX4PH Rev. N. AX416, AX436, AX460, AX466 & AX468 Single and dual input analyzers for ph/redox (ORP) User Guide IM/AX4PH Rev. N Single and dual input analyzers for ph/redox (ORP) The Company We are an established world force in the design and manufacture of measurement products for industrial process

More information

Manual ph Meter PCE-228

Manual ph Meter PCE-228 PCE Americas Inc. 711 Commerce Way Suite 8 Jupiter FL-33458 USA From outside US: +1 Tel: (561) 320-9162 Fax: (561) 320-9176 info@pce-americas.com PCE Instruments UK Ltd. Units 12/13 Southpoint Business

More information

Mini Agg 1-10 (DC/AC)

Mini Agg 1-10 (DC/AC) TALGIL Computing & Control Ltd. ISRAEL TALGIL COMPUTING & CONTROL LTD. NAAMAN CENTER, HAIFA - ACCO ROAD 7000 P.O.BOX 775 KIRYAT MOTZKIN 26119, ISRAEL TEL: 972-4-8775947; 972-4-8775948 FAX: 972-4-8775949

More information

Installation instruction and user manual. KT-2 Spatial corrector

Installation instruction and user manual. KT-2 Spatial corrector Installation instruction and user manual KT-2 Spatial corrector The manual has to be handed over to the end user after installation. ID.: 17-16-13-2960-03 1.2017 EN Installation instruction and user manual

More information

Manual. NanoTron Dual Timer. Installation Maintenance Repair Manual

Manual. NanoTron Dual Timer. Installation Maintenance Repair Manual Manual NanoTron Dual Timer Installation Maintenance Repair Manual Advantage Controls P.O. Box 1472 Muskogee, OK 74402 Phone: 800-743-7431 Fax: 888-686-6212 www.advantagecontrols.com email: support@advantagecontrols.com

More information

CONGRATULATIONS ON YOUR CHOICE

CONGRATULATIONS ON YOUR CHOICE USER GUIDE CONGRATULATIONS ON YOUR CHOICE We are pleased to offer you the finest technology in grain quality control. Your moisture meter was submitted through an extensive quality control process to ensure

More information

Content. Ⅰ General information 1. Ⅱ Product description 2. Ⅲ System description 3. Ⅳ Fault message 5

Content. Ⅰ General information 1. Ⅱ Product description 2. Ⅲ System description 3. Ⅳ Fault message 5 Content Ⅰ General information 1 Ⅱ Product description 2 Ⅲ System description 3 Ⅳ Fault message 5 Ⅴ Packing list 5 Ⅰ General information Intelligent controller series for solar water heating control system

More information

GRYF. Measuring Instruments. For Fisheries. Practice and research

GRYF. Measuring Instruments. For Fisheries. Practice and research Manufacturer of measuring systems For Fisheries Practice and research www.gryf.eu HB, spol. s r. o., Cechova 314, 580 01 Havlickuv Brod, Telefon: 569 425 024 XBase XBP XBase XBP The XBase XBP measuring

More information

AK2100 PROGRAMMABLE CONTROLLER

AK2100 PROGRAMMABLE CONTROLLER AK2100 PROGRAMMABLE CONTROLLER 370 N. Wabasha St. St. Paul, MN 55102 PROGRAMMING GUIDE Phone 1-800-352-5326 (1-800-35-CLEAN) Guide No. 1 Vs.B 6/15/01 32150/0400/0601 CONTENTS INTRODUCTION... 3 window NAVIGATion...

More information

User Manual. Item no.: Otto Graf GmbH Carl-Zeiss-Str. 2-6 Tel.: +49(0) Kunststofferzeugnisse D Teningen Fax: +49(0)

User Manual. Item no.: Otto Graf GmbH Carl-Zeiss-Str. 2-6 Tel.: +49(0) Kunststofferzeugnisse D Teningen Fax: +49(0) User Manual AquaControl + Rainwater System Controller Item no.: 351027 Otto Graf GmbH Carl-Zeiss-Str. 2-6 Tel.: +49(0)7641-5890 Kunststofferzeugnisse D-79 331 Teningen Fax: +49(0)7641-58950 Page 1 Figure

More information

WK7200. Water Quality Test Kit USER S MANUAL

WK7200. Water Quality Test Kit USER S MANUAL WK7200 USER S MANUAL Water Quality Test Kit INTRODUCTION: Thank you for selecting model WK7200 microprocessor-based waterproof Water Quality Test Kit. It is used to measure a wide range of ph, ORP, Conductivity,

More information

Operating Manual LF1-LF4 i

Operating Manual LF1-LF4 i Operating Manual Oct. 2005 Fillerkampsweg 1 5 31832 Springe OT Eldagsen Tel.: 05044/887-0 (Fax: -99) E-Mail: info@iotronic.de Internet: http://www.iotronic.de Page 3 Contents 1.0 General Guidelines for

More information

MultiTherm Shaker. Operations Manual Item: H5000-H and H5000-HC

MultiTherm Shaker. Operations Manual Item: H5000-H and H5000-HC MultiTherm Shaker Operations Manual Item: H5000-H and H5000-HC Foreword Thank you for purchasing a MultiTherm Shaker. This operations manual contains instructions for the care of this Instrument. In order

More information

Assembly and operating instructions DULCOMARIN II, P-Module (Power Supply Module with Relay) DXMaP

Assembly and operating instructions DULCOMARIN II, P-Module (Power Supply Module with Relay) DXMaP Assembly and operating instructions DULCOMARIN II, P-Module (Power Supply Module with Relay) DXMaP A0479 Please enter the identity code of your device here! DXMa _ Please carefully read these operating

More information

ST-292 User s manual. User manual ST-292 v1-3

ST-292 User s manual. User manual ST-292 v1-3 ST-292 User s manual User manual ST-292 v1-3 1 TECH I. Safety Before using the device for the first time the user should read the following regulations carefully. Not obeying the rules included in this

More information

BS 287 DUAL CHANNEL POWER SUPPLY. User Manual. January 2017 V1.0

BS 287 DUAL CHANNEL POWER SUPPLY. User Manual. January 2017 V1.0 BS 287 DUAL CHANNEL POWER SUPPLY User Manual January 2017 V1.0 Table of contents 1.0 SAFETY INSTRUCTIONS... 3 2.0 GENERAL DESCRIPTION PS 289... 4 3.0 MECHANICAL INSTALLATION... 5 4.0 MAINS POWER & SAFETY

More information

Operating manual Solareg II BASIC DC

Operating manual Solareg II BASIC DC Operating manual Solareg II BASIC DC Microcontroller-controlled temperature difference controller for solar thermal systems Explanation of the graphic symbols Attention! Symbol indicates possible dangers

More information

AerMonitor AM Aer Monitor User's Manual. Version-0.1

AerMonitor AM Aer Monitor User's Manual. Version-0.1 AerMonitor AM-1015 Aer Monitor User's Manual Version-0.1 AerMonitor AM-1015 Copyright Notice This document is copyrighted, 2013. All rights are reserved. Firich Enterprise Co., Ltd reserves the right to

More information

ZEPHYR Compact Haze Machine

ZEPHYR Compact Haze Machine ZEPHYR Compact Haze Machine Item ref: 160.464UK User Manual Version 1.0 Caution: Please read this manual carefully before operating Damage caused by misuse is not covered by the warranty Introduction Thank

More information

*suitable both for membrane sensors or chlorine open cell

*suitable both for membrane sensors or chlorine open cell CTRL POOL THE SIMPLE, RELIABLE, COST EFFECTIVE SYSTEMS FOR SMALL POOLS CTRL POOL is a compact system, with single or dual controller and peristaltic dispensers all in one enclosure. CTRL POOL is extremely

More information

CONTROLLERS. Chemical Injection skids. Water Quality Monitoring Systems cum dosing (WQMSD) Mobile Disinfection/Dosing systems

CONTROLLERS. Chemical Injection skids. Water Quality Monitoring Systems cum dosing (WQMSD) Mobile Disinfection/Dosing systems Chemical Injection skids CONTROLLERS Water Quality Monitoring Systems cum dosing (WQMSD) Mobile Disinfection/Dosing systems Containarised Water Treatment systems CONTROLLERS AND MEASUREMENTS TOUCH controller

More information

Always there to help you. Register your product and get support at CVR600. Question? Contact Philips.

Always there to help you. Register your product and get support at   CVR600. Question? Contact Philips. Always there to help you Register your product and get support at www.philips.com/support Question? Contact Philips CVR600 User manual Contents 1 Safety 2 2 Your car driving recorder 3 Introduction 3

More information

DDS-12DW Benchtop Conductivity Meter. Instruction Manual BANTE INSTRUMENTS CO., LTD

DDS-12DW Benchtop Conductivity Meter. Instruction Manual BANTE INSTRUMENTS CO., LTD DDS-12DW Benchtop Conductivity Meter Instruction Manual BANTE INSTRUMENTS CO., LTD DDS-12DW Benchtop Conductivity Meter 1 Introduction Thank you for selecting the DDS-12DW benchtop conductivity meter.

More information

Type MS04. Redox potential sensor cube. Operating Instructions

Type MS04. Redox potential sensor cube. Operating Instructions Redox potential sensor cube Operating Instructions We reserve the right to make technical changes without notice. Technische Änderungen vorbehalten. Sous réserve de modifications techniques. Bürkert SAS,

More information

CH142: Instructions for the Vernier LabPro

CH142: Instructions for the Vernier LabPro 1 CH142: Instructions for the Vernier LabPro INTRODUCTION: The Vernier LabPro is a versatile data collection interface that can be used in combination with more than 45 sensors, and with a computer, TI

More information

Recorder DMX DR-Pro Rack

Recorder DMX DR-Pro Rack Manual Recorder DMX DR-Pro Rack Inhaltsverzeichnis 1. Safety instructions... 3 1.1. FOR SAFE AND EFFICIENT OPERATION... 3 2. Overview... 5 2.1. Front view... 5 2.2. Rear view... 6 3. Control... 7 3.1.

More information

Model P4470 Save A Watt Operation Manual

Model P4470 Save A Watt Operation Manual Model P4470 Save A Watt Operation Manual Thank you for purchasing the P4470 Save A Watt. This operating manual will provide an overview of the product, safety instructions, a quick guide to operation,

More information

ProMinent DDC Analyzers

ProMinent DDC Analyzers Overview: DDC pk_5_045 The Multi-channel Measuring and Control System DULCOMARIN II has the following features: 5.7", 1/4 VGA color display for ease of operation Integrated data logger with screen recorder:

More information

SIGNET 5700 ph/orp Monitor - ORP Instructions

SIGNET 5700 ph/orp Monitor - ORP Instructions SIGNET 5700 ph/orp Monitor ORP Instructions ENGLISH 35700.0901 H (6/01) English CAUTION! Refer to instruction manual for more details. Remove power to unit before wiring input and output connections. Follow

More information

Dryer. M720 Programming and Operation Manual. July 15, 2015 Revision 1.51

Dryer. M720 Programming and Operation Manual. July 15, 2015 Revision 1.51 Dryer M720 Programming and Operation Manual July 15, 2015 Revision 1.51 Contents 1 Important Safety Information 1 1.1 FOR YOUR SAFETY - CAUTION!............................. 1 2 Control Overview 2 2.1

More information

Zone Remote Controller PAC-ZC40L/40H/80L/80H-E

Zone Remote Controller PAC-ZC40L/40H/80L/80H-E Zone Remote Controller PAC-ZC40L/40H/80L/80H-E Instruction Book Prior to use, thoroughly read the instructions in this manual to use the product correctly. Retain this manual for future reference. Make

More information

Please read and retain these instructions for future reference v002: 14/03/17. Cradle, Charger, Instruction manual, Lithium-ion Battery 3.7 V d.c.

Please read and retain these instructions for future reference v002: 14/03/17. Cradle, Charger, Instruction manual, Lithium-ion Battery 3.7 V d.c. Power Details: AC Charger Input voltage: 100-240V ~ 50/60Hz, 200mA Cradle Input Voltage: DC 5V, 500mA Cradle Output Voltage: DC 5V, 500mA Accessories: Cradle, Charger, Instruction manual, Lithium-ion Battery

More information

Pillbox Timer with Pulsemeter Model: PMP238 User Manual

Pillbox Timer with Pulsemeter Model: PMP238 User Manual Pillbox Timer with Pulsemeter Model: PMP238 User Manual 1/10 PILLBOX TIMER WITH PULSEMETER MODEL: PMP238 INSTRUCTION MANUAL INTRODUCTION Congratulations on your purchase of the easy-to-use Pillbox timer

More information

LevCon. Liquid Level Indicator / Controller DIAL-SJE ( )

LevCon. Liquid Level Indicator / Controller DIAL-SJE ( ) LevCon Liquid Level Indicator / Controller 1-888-DIAL-SJE (1-888-342-5753) www.sjerhombus.com LEVCON CONTROLLER INTRODUCTION The LevCon set point level controller is a self-contained microprocessor controlled

More information

X4 Plus Dosing Pump User Manual (V1.0)

X4 Plus Dosing Pump User Manual (V1.0) X4 Plus Dosing Pump User Manual (V1.0) Kamoer Fluid Tech (Shanghai) Co.,Ltd. www.kamoer.com 1 Contents CONTENTS... 2 WARRANTY... 3 NOTICE... 4 1. INTRODUCTION... 5 1.1 ABOUT... 5 1.2 UNPACKING... 6 1.3

More information

F4 Dosing Pump User Manual (V1.0)

F4 Dosing Pump User Manual (V1.0) F4 Dosing Pump User Manual (V1.0) Kamoer Fluid Tech (Shanghai) Co.,Ltd. www.kamoer.com Contents WARRANTY... 2 NOTICE... 3 1. INTRODUCTION... 4 1.1 ABOUT... 4 1.2 UNPACKING... 5 1.3 STRUCTURE DIAGRAM...

More information

X-MG-51. DMX Merger User Manual

X-MG-51. DMX Merger User Manual X-MG-51 Merger User Manual X-MG-51 Merger User Manual Issue 1 (-7-2) Copyright SWISSON AG No part of this documentation may be reproduced or transmitted in any form or by any means, electronic or mechanical,

More information

Z-380 Fazer Machine User Manual English

Z-380 Fazer Machine User Manual English Z-380 Fazer Machine User Manual English 2015 Antari Lighting and Effects Ltd. User Manual Safety Information Please read the following safety information carefully before operating the machine. Information

More information

MXD70 SERIES. Multi-parameter Monitor. ph / Redox Setup and Operating Guide

MXD70 SERIES. Multi-parameter Monitor. ph / Redox Setup and Operating Guide MXD70 SERIES Multi-parameter Monitor ph / Redox Setup and Operating Guide Preface Preface Product warranty The MXD70 ph/redox Input Card has a warranty against defects in materials and workmanship for

More information

MANUAL PELITT MINI 1

MANUAL PELITT MINI 1 MANUAL PELITT MINI 1 TABLE OF CONTENTS 1. Warnings 3 2. Getting Started 3 3. Your Phone 4 4. File Manager 4 5. Phone book 4 6. Fun&Games 4 7. Call center 4 8. Messaging 4 9. Multimedia 5 10. Organizer

More information

Please enter the identcode of your module!

Please enter the identcode of your module! Supplementary Instructions DULCOMARIN II, Sensor Module (ph, redox/orp, temperature) DXMaM DXMa Please enter the identcode of your module! These supplementary instructions apply only in conjunction with

More information

Weekday / weekend room temperature controller

Weekday / weekend room temperature controller s 2 203 Weekday / weekend room temperature controller Heating applications REV17.. Mains-independent, battery-operated room temperature controller featuring user-friendly operation, easy-to-read display

More information