VariTrans P Standard-Signal Isolators
|
|
- Pierce Kennedy
- 5 years ago
- Views:
Transcription
1 VariTrans Standard-Signal Isolators Warranty Defects occurring within 5 years from delivery date shall be remedied free of charge at our works (carriage and insurance paid by sender). The professional standardsignal isolator. With calibrated range selection and broad-range mains selection. The task Guaranteeing reliable and safe system operation requires galvanic isolation between the measuring signal sensors and the control (e.g. PCS, SPC etc.). The problems Difficulties are often caused by a lack of space to install the isolators. In large systems in particular measuring signals are sent across long distances and providing a loadable and isolated signal is essential. The innovation Calibrated selection of the input and output ranges with DIP switches allows the new VariTrans professional standardsignal isolators from Knick to be used universally without tiresome readjustment. The broad-range mains adapter for all normal supply voltages from 20 to 253 V AC/DC is an unrivalled feature for isolators in such a compact modular case. The housing The new modular case which is only 12.5 mm wide and has plug-in screw clamp terminals now allows simple and fast assembly or even prewiring of the control cabinet. Housings with fixed screw clamp terminals are also available for extremely high mechanical loading. Adjusting the isolator has been simplified as the housing is easy to open. The function principle The analog signal transfer with transformer isolation and the new digitally controlled range selection system guarantee almost perfect signal transfer: Amplification error only 0.08 % Excellent pulse waveshape Extremely low residual ripple Maximum long-term stability and reliability The technology A microcontroller monitors the control element settings and controls the calibrated range selection. Signal transmission interference caused for example by contact resistances at the range selectors is therefore ruled out. The Vari mains adapter allows the units to be used in any country with practically any power supply. The extremely low power consumption and the resulting minimum self-heating significantly increase the reliability. This is why we give a 5-year warranty
2 VariTrans Flexible and precise Calibrated signal switch-over, easy selection of input and output range without tedious readjustment. Vari 20 to 253 V AC/DC broad range mains adapter Universally applicable for all common supply voltages Extremely compact design 12.5 mm modular case; up to 80 active isolators per meter top-hat rail 3-port isolation Protects against erroneous measurements or damage due to parasitic voltages High accuracy No distortion of measured signal Protective separation to VDE 0100 Part 410 Protects service personnel and downstream devices against impermissibly high voltages Maximum reliability Omits repair effort and the related costs Quick and easy configuring Housing can easily be opened. A pull-out lock on the electronics section prevents disengagement of the pcb. Pluggable screw-clamp terminals Easy and time-saving mounting and prewiring of control cabinets Individual test certificate Based on EN , for example for QM documentation
3 Product line Instruments Ref. No. Ref. No. Pluggable screw Fixed screw clamp Input Output clamp terminals terminals input and output H1 F1 adjustable to calibrated ranges with permanent 0 to 20 ma 0 to 20 ma P H1 P F1 settings 0 to 20 ma 4 to 20 ma P H1 P F1 0 to 20 ma P H1 P F1 4 to 20 ma 0 to 20 ma P H1 P F1 4 to 20 ma 4 to 20 ma P H1 P F1 4 to 20 ma P H1 P F1 0 to 20 ma P H1 P F1 4 to 20 ma P H1 P F1 P H1 P F1 Specifications Input data Inputs 0 to 20 ma terminal/switch selectable (factory setting 0 to 20 ma) 4 to 20 ma or with permanent settings (see Product line) Input resistance Current input voltage drop approx. 250 mv at 20 ma Voltage input approx. 1 M½ Input capacitance Approx. 1 nf Overload Current input ²300 ma Voltage input V limiting by suppressor diode to 30 V, max. permissible permanent current 30 ma Output data Output 0 to 20 ma selectable (factory setting 0 to 20 ma) 4 to 20 ma or with fixed setting (see Product line) (negative signals are transmitted up to approx. 5 % full scale) Load For output current ²12 V (600 ½ at 20 ma) For output voltage ²10 ma (1 k½ at 10 V) 1) Offset 20 µa / 10 mv Residual ripple <10 mv rms 1) Higher load at voltage output on request
4 VariTrans Specifications Further data Gain error <0.08 % meas. value Temperature coefficient 2) <50 ppm/k of final value Bandwidth > 10 khz; F1/H1 switchable to < 10 Hz Test voltage 4 kv~ input against output against power supply Working voltage 600 V AC/DC for overvoltage category II and pollution degree 2 to EN (basic insulation) For applications with high working voltages, take measures to prevent accidental contact and make sure that there is sufficient distance to adjacent devices or sufficient insulation between them. Protection against Reinforced insulation to EN and protective separation to VDE 0100 Part 410 as electrical shock defined in VDE 0106 Part 101 up to 300 V AC/DC between input and output and power supply for overvoltage category II and pollution degree 2. For applications with high working voltages, take measures to prevent accidental contact and make sure that there is sufficient distance to adjacent devices or sufficient insulation between them. EMC 3) 89/336/EEC EN , EN EN , EN Surge withstand 5 kv, 1.2/50 ms, to IEC Ambient temperature Operation 10 to +70 ºC Transport and storage 40 to +85 ºC supply 20 to 253 V AC/DC AC 48 to 62 Hz, approx. 2 VA DC approx. 0.9 W Construction Modular case, For dimensions see dimension drawings Type H1 with pluggable screw clamp terminals Type F1 with fixed screw clamp terminals Protection IP 20 Weight approx. 150 g 2) Average TC in specified operating temperature range 10 C to +70 C 3) Minor deviations possible during interference
5 Typical applications Potential isolation for safe coupling of the measuring signals to the evaluating electronics Transmitter e.g. C, bar 0/4 to 20 ma e.g. SPC, PCS Signal conversion e.g. for converting voltage into current signals for interference-free signal transmission over large distances Voltage output 0 to10 V 4 to 20 ma e..g. indicators, SPC, PCS Load increase e.g. for measuring signals with low loadability Current output e.g. C, bar 0 to 20 ma max. load 50 W, e.g.spc R I = 12,5 W 0 to 20 ma max. load 600 W Subject to change!
6 VariTrans Typical applications Signal multiplication e.g. for safe evaluation of measuring signals in different instruments Current output Voltage output 0/4 to 20 ma indicators indicators indicators indicator 2-wire application for easy implementation of 2-wire loops 2-wire transmitter e.g. C, bar 4 to 20 ma 0/4 to 20 ma or 24 V DC Mains adapter supply Block diagram + Voltage input Current input + C 1 nf Z 30 V C 1 nf C 1 nf + Z 18 V Output Subject to change! supply 20 to 253 V AC/DC
7 Dimension drawings and terminal assignments Case with pluggable screw clamp terminals 12.5 [0.49] 111 [4.37] Pluggable screw clamp terminals 99 [3.90] Metal lock for fastening on top-hat rail Case with fixed screw clamp terminals 12.5 [0.49] 111 [4.37] Fixed screw clamp terminals 99 [3.90] Terminal assignments 1 Input + current 2 Input current 3 Input + voltage 4 Input voltage 5 Output + 6 Output 7 supply ~ 8 supply ~ Metal lock for fastening on top-hat rail Wire cross-section max. 2.5 mm 2 Multi-wire connection max. 1 mm 2 (two wires with same cross-section) Note: All dimensions in mm [inches]. Subject to change!
VariTrans A The specialist for ±10 V and ±20 ma. With calibrated range selection and broad-range power supply.
Universal Isolation Amplifiers The specialist for ±10 V and ±20 ma. With calibrated range selection and broad-range power supply. The Housing At a width of just 12.5 mm, the modular housing with pluggable
More informationVariTrans P The Problem The variety of tasks results in a large number of different devices.
Universal Isolation Amplifiers The Multimeter among the isolation amplifiers. With 480 switchable calibrated ranges and broad-range power supply. The broad-range power supply for all common supply voltages
More informationWG 20. The WG 20 achieves an extraordinarily. accuracy for hazardous-area. applications.
Modular Housings for Hazardous Areas For transmission of 0(4)... 20-mA signals from hazardous areas or supply of intrinsically safe 2-wire transmitters. The Task The power supply/isolator is used to supply
More informationStandard-Signal Isolation Amplifiers. VariTrans A 21000
Standard-Signal Isolation Amplifiers The first standard-signal isolation amplifier with protective separation and broad-range power supply in the 6-mm class. The Task Isolation and conversion of 0... 20
More informationVariTrans B The world s first 3-port standard signal isolator in a 6-mm modular housing.
Standard-Signal Isolation Amplifiers The world s first 3-port standard signal isolator in a 6-mm modular housing. The Task Isolation and, if required, conversion of 0... 20 ma, 4... 20 ma, and 0... 10
More informationHigh-Voltage Isolation Amplifiers / Shunt Isolators. VariTrans P 42000
Universal high-voltage isolator. Input voltages up to Vin = ±3600 V. The Task In high-voltage systems, unipolar or bipolar voltage signals ranging from 100 V to 3600 V must be galvanically isolated and
More informationSignal Doublers. VariTrans A 20300
ProLine Interface Technology Signal Doublers Signal doublers with two switchable calibrated outputs in a 6 mm housing, also for applications with high output loads. The Task Isolation and transmission
More informationAlarm Unit DG 3200 Control And Monitor Standard Signals
Alarm Unit DG 3200 Control And Monitor Standard Signals With the Alarm Unit DG 3200 DRAGO is extending its offer on high-functional and high-reliable components of the interface technique. The Alarm Unit
More informationSensoTrans DMS A 20220
ProLine Interface Technology Strain Gauge Transmitters The transmitter for strain gauge full bridges in a 6 mm housing. The Task In many different industrial applications strain gauges are used to continuously
More informationSensoTrans DMS P 32200
ProLine Interface Technology Strain Gauge Transmitters The transmitters for strain gauge full bridges in a 6 mm housing with infrared interface and SIL approval. The Task In many different industrial applications
More informationContact protection relay
Contact protection relay Ordering details SVR 450 08 F0000 The protects sensitive control contacts from excessive load. It can be used with latching function or without. Bounce time of control contacts
More informationDT1102 V (PS) Fully Configurable Galvanic Isolator. Operating Instructions
(PS) Fully Configurable Galvanic Isolator Operating Instructions Contents 1. About this document...4 1.1. Function... 4 1.2. Target group... 4 1.3. Symbolism used... 4 2. For your safety...5 2.1. Authorized
More informationIndicators. Hazardous-Area Indicators. 830 X R Loop-Powered 16 Process Indicator. 830 X S1 Loop-Powered 16 Process Indicator
Hazardous-Area 830 X R Loop-Powered 16 830 X S1 Loop-Powered 16 830 X S2 Loop-Powered 16 15 Loop-Powered Digital 830 X Loop-Powered 830 X R 830 X S1 830 X S2 The 830 X loop-powered digital indicators are
More informationPSR-SCP- 24DC/SSM/2X1 PSR-SPP- 24DC/SSM/2X1
PSR-SCP- DC/SSM/2X1 PSR-SPP- DC/SSM/2X1 Safety Relay With Downtime Monitoring INTERFACE Data Sheet PHOENIX CONTACT - 05/2006 Description The PSR-...- DC/SSM/2X1 safety relay can be used in safety circuits
More informationUser's Guide. MiniTec TM Series Model MN25 MultiMeter
User's Guide MiniTec TM Series Model MN25 MultiMeter Warranty EXTECH INSTRUMENTS CORPORATION warrants this instrument to be free of defects in parts and workmanship for one year from date of shipment (a
More informationS-14 S-14. Compact Digital Multimeter. Compact Digital Multimeter
S-14 Compact Digital Multimeter S-14 Compact Digital Multimeter SAFETY INFORMATION The following safety information must be observed to insure maximum personal safety during the operation at this meter
More informationOPERATING INSTRUCTION
OPERATING INSTRUCTION AUTORANGING MULTIMETER MAX Ω F C 10A MAX every 15 min. COM V SAFETY INFORMATION The following safety information must be observed to insure maximum personal safety during the operation
More informationUser s Guide. 600A AC Clamp Meter. Model 38387
User s Guide 600A AC Clamp Meter Model 38387 Safety International Safety Symbols This symbol, adjacent to another symbol or terminal, indicates the user must refer to the manual for further information.
More informationDM-918 OPERATIONS MANUAL AUTORANGING MULTIMETER
DM-918 OPERATIONS MANUAL AUTORANGING MULTIMETER SAFETY INFORMATION The following safety information must be observed to ensure maximum personal safety during the operation of this meter: This meter is
More informationMINI MCR-SL-UI-2I(-SP)(-NC)
Data Sheet 03/2005 Product Description Features Configurable signal duplicator MINI MCR-SL-UI-2I(-SP)(-NC) is used to electrically isolate, condition, amplify, and filter analog standard signals. On the
More informationTransducers for Pt-100/1000, Resistors
Transducers for Pt-100/1000, Resistors Microprocessor-based technology General Description Isolating transducers with digital programming of ranges, for DIN-rails or for printed circuit boards. Modules
More informationPHOENIX CONTACT - 01/2010. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.
Uninterruptible power supply with integrated power supply unit INTERFACE Data sheet 104211_en_00 1 Description PHOENIX CONTACT - 01/2010 Features The MINI-DC-UPS provide an uninterruptible DC voltage both
More informationUser's Guide. Extech AM A AC Analog Clamp Meter
User's Guide Extech AM300 300A AC Analog Clamp Meter Introduction Congratulations on your purchase of the Extech AM300 Analog Clamp Meter. This device measure AC Voltage and Current, DC Voltage, and Resistance.
More informationNI REM Remote I/O Overview DATASHEET. Analog Output Module for Remote I/O
DATASHEET NI REM-11115 Analog Output Module for Remote I/O Four voltage output ranges to choose from (0 V to 10V, ±10V, 0 V to 5 V, and ±5V) Two current output ranges to choose from (0 ma to 20mA, 4 ma
More informationRM35LM33MW liquid level control relay RM35-L V AC/DC
Characteristics liquid level control relay RM35-L - 24..240 V AC/DC Complementary reset time maximum switching voltage Main range of product product or component type relay type relay name relay monitored
More informationRE7YA12BU time delay relay for star-delta starter s - 24 V AC DC - 2OC
Characteristics time delay relay for star-delta starter - 0.05..1 s - 24 V AC DC - 2OC Main Range of product Product or component type Contacts type and composition Component name Time delay type Time
More informationData Sheet T 6493 EN. TROVIS 6400 Automation System TROVIS 6493 Compact Controller. For panel mounting (front frame 48 x 96 mm/1.89 x 3.
Data Sheet T 6493 EN TROVIS 6400 Automation System TROVIS 6493 Compact Controller For panel mounting (front frame 48 x 96 mm/1.89 x 3.78 inch) Application Digital controller to automate industrial and
More informationPHOENIX CONTACT - 08/2009. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.
Primary-switched power supply for building automation INTERFACE Data sheet 103505_en_02 1 Description PHOENIX CONTACT - 08/2009 Features STEP POWER power supply units for building automation The new STEP
More informationMODEL 9250 Preliminary data sheet
Delivery: ex stock Warranty: 24 months Universal Instrumentation Amplifier for strain gage, potentiometric, DC/DC and incremental sensors MODEL 9250 Preliminary data sheet NEW burster TEDS Highlights Ultra-fast
More information703 Laboratory Conductivity Meter
703 Laboratory Conductivity Meter Sensoface Sensoface monitors the sensor and measuring equipment and provides information on sensor selection and handling. It reports clock memory loss and requests regular
More informationProduct and Applications Description. Note. Example of Operation. Installation Instructions. Application Programs WARNING
Product and Applications Description Note If the application program is not loaded completely by the ETS, you had better interrupt the 24 V voltage supply of the I/O-module during the loading interval.
More informationMINI-DC-UPS/12DC/4. Extract from the online catalog. Order No.:
Extract from the online catalog MINI-DC-UPS/12DC/4 Order No.: 2866598 Uninterruptible power supply with integrated power supply unit, 4 A, in combination with MINI-BAT/12/DC 1.6 Ah or 2.6 Ah Commercial
More informationQUINT-PS/1AC/24DC/10. Extract from the online catalog. Order No.:
Extract from the online catalog QUINT-PS/1AC/24DC/10 Order No.: 2866763 DIN rail power supply unit 24 V DC/10 A, primary-switched mode, 1- phase. The SFB technology (Selective Fusebreaking Technology)
More informationLED Driver Linear / area dimming
Driver LC 75W 100 400mA 1-10V lp EXC EXCITE series Product description Built-in constant current LED Driver Dimmable via 1... 10 V interface Dimming range 10 100 % (Depending on load, for details refer
More informationitemp TMT180 Technical information
Technical information itemp TMT180 Temperature head transmitter For resistance thermometers Pt100, settable using a PC, for installation in a sensor head Form B Application PC programmable (PCP) Temperature
More informationPHOENIX CONTACT - 05/2008. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.
Primary switched power supply, 1-phase, output current: 5 A ITERFACE Data Sheet 102777_en_03 1 Description PHOEIX COTACT - 05/2008 Features TRIO POWER is the DI-rail-mountable power supply unit with basic
More information7032 Digital-Analog Multimeter
7032 Digital-Analog Multimeter OPERATOR S MANUAL CONTENTS: 1. Safety precautions and procedures 1 1.1. Preliminary 1 1.2. During Use 2 1.3. After Use.. 2 2. General Description. 3 3. Preparation for Use..
More informationPSR-SCP- 24DC/URM4/4X1/2X2/B PSR-SPP- 24DC/URM4/4X1/2X2/B
Safety Relay as a Contact Extension Block INTERFACE Data Sheet PHOENIX CONTACT - 05/2006 Description The PSR-...- 24DC/URM4/4X1/2X2/B safety relay can be used as a contact extension block in safety circuits
More informationRM4TR31 three-phase network control relay RM4-T - range V
Characteristics three-phase network control relay RM4-T - range 160..220 V Complementary [Us] rated supply voltage Control threshold undervoltage Control threshold overvoltage Output contacts Main Range
More informationRE7RM11BU off-delay timing relay with control contact s - 24 V AC DC - 1OC
Characteristics off-delay timing relay with control contact - 0.05..1 s - 24 V AC DC - 1OC Main Range of product Product or component type Component name Time delay type Time delay range [Us] rated supply
More informationPHOENIX CONTACT - 06/2007. DANGER OF EXPLOSION! Remove an item only when it is not connected to power or if it is located in the non-explosive area.
Primary switched power supply, 3-phase, output current: 40 A INTERFACE Data Sheet 102782_01_en PHOENIX CONTACT - 06/2007 Description TRIO POWER is the rail mountable 24 V power supply unit with basic functions.
More informationIndustriefunkuhren. Technical Manual. Signal Converter. for DIN Rail Mounting Series 4800xx-yy ENGLISH
Industriefunkuhren Technical Manual Signal Converter for DIN Rail Mounting Series 4800xx-yy ENGLISH Version: 01.01-19.07.2007 2 / 23 Signal Converter 4800 - V01.01 INPORTANT NOTES Downloading Technical
More informationDEIF A/S. TAS-331DG Selectable AC transducer G (UK) Installation and start up instructions. Watt or var transducer
Installation and start up instructions TAS-331DG Selectable AC transducer 4189300008G (UK) Watt or var transducer Supply and measuring voltage up to 690V DEIF A/S Configuration via PC-interface possible
More informationRMCN22BD Analog Converter ma - for Zelio Analog
Characteristics Analog Converter - 4..20 ma - for Zelio Analog Main Commercial Status Range of product Product or component type Analogue input type Analogue output type Commercialised Zelio Analog Voltage/Current
More informationLED Driver Linear / area dimming
Driver LC 75W 100 400mA 1-10V lp EXC EXCITE series Product description Built-in constant current LED Driver Dimmable via 1... 10 V interface Dimming range 10 100 % (Depending on load. For details refer
More informationRM35LM33MW liquid level control relay RM35-L V AC/DC
Characteristics liquid level control relay RM35-L - 24..240 V AC/DC Complementary Reset time Maximum switching voltage [Un] rated nominal voltage Supply voltage limits Operating voltage tolerance Power
More informationMODEL AAMA - UNIVERSAL SIGNAL CONDITIONING MODULE
Bulletin No. AAMA-G Drawing No. LP0368 Released 05/13 Tel +1 (717) 767-6511 Fax +1 (717) 764-0839 www.redlion.net MODEL AAMA - UNIVERSAL SIGNAL CONDITIONING MODULE 3-WAY ISOLATION OF ANALOG SIGNALS UNIVERSAL
More informationPHOENIX CONTACT - 07/2006
Buffer module with maintenance-free capacitor-based power storage device INTERFACE Data sheet 102035_03_en PHOENIX CONTACT - 07/2006 Description Short-term mains interruptions are bridged by QUINT BUFFER,
More informationPHOENIX CONTACT - 05/2008. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.
Primary switched power supply, 1-phase, output current: 5 A ITERFACE Data Sheet 103349_en_00 1 Description PHOEIX COTACT - 05/2008 Features TRIO POWER is the DI-rail-mountable power supply unit with basic
More informationZelio Control-modular measurement and control relays 1
Presentation, description 1 106439 RM35 TM111MW Presentation Motor temperature measurement and 50MW and RM35 TM250MW monitor the following, on 3-phase supplies: correct sequencing of phases L1, L2 and
More informationCompact Inductive Proximity Sensor
SERIES Compact Inductive Proximity Sensor Amplifier Built-in High functionality together with robust housing and flexible cable Miniature is an amplifier built-in inductive proximity sensor having a diameter
More informationSTEP-PS/1AC/24DC/1.75
Primary-switched power supply, 1 AC, output current 1.75 A INTERFACE Data Sheet 103506_en_00 1 Description PHOENIX CONTACT - 05/2008 Features STEP POWER power supply units for building automation The new
More informationLED Driver Linear / area fixed output
Driver C 57W 8-5mA flexc lp ACED series Product description Built-in constant current ED Driver ew version DC operating with E marking Adjustable output current between 8 and,5 ma Max. output power 57
More informationQUINT-PS AC/24DC/10
Extract from the online catalog QUINT-PS-100-240AC/24DC/10 Order No.: 2938604 DIN rail power supply unit 24 V DC/10 A, primary switched-mode, 1- phase Commercial data EAN 4017918890537 Pack 1 Pcs. Customs
More information96x48. gal/h. Digital panel meter 4½-digit DV4. Without setpoints. Sensor supply
gal/h Digital panel meter 4½digit DV4 Without setpoints Sensor supply status 22/05/06 panelmeteranalog_gb.doc page 9 Digital panel meter Direct voltage Direct current gal/h Direct voltage, direct current
More informationData sheet ACT20P ACT20P-CMT-10-AO-RC-S. Phone: Fax: Web: - [!
-CMT-10-AO-RC-S [!-] General ordering data Type -CMT-10-AO-RC-S Order No. 1510470000 Version Current-measuring transducer GTIN (EAN) 4050118319583 Qty. 1 pc(s). -CMT-10-AO-RC-S Technical data Dimensions
More informationABL1REM24100 regulated SMPS - single phase V input - 24 V output W
Characteristics regulated SMPS - single phase - 100..240 V input - 24 V output - 240 W Complementary Input voltage limits Network frequency limits Inrush current Main Range of product Product or component
More informationMulti-range pressure and differential pressure transmitter
Page 1/6 Multi-range pressure and differential pressure transmitter Type 402005 Applications Ventilation Air conditioning Clean-room technology Flue draft mechanisms Filter monitoring Brief description
More informationPower supply CP-C 24/5.0
2CDC 271 064 F0004 Features Supply voltage ranges: 85-264 V AC, 100-350 V DC Output voltage adjustable from 22-28 V DC, default setting 24 V DC 0,5 % 5 A output current Open-circuit, overload and continous
More informationRTU500 series Data Sheet Power Supply CP-E 24/2.5
Data Sheet Power Supply CP-E 24/2.5 Power Supply CP-E 24/2.5 Application The primary switch mode power supply offers two voltage input ranges. This enables the supply with AC or DC. Furthermore it is equipped
More informationOperating instructions. Standstill monitor A / / 2011
Operating instructions Standstill monitor A300 UK 1 2 3 4 5 6 7 8 7390337 / 01 02 / 2011 1 2 3 4 5 6 7 8 switchpoint min max pulse/min power Made in Germany ifm electronic gmbh D 45127 Essen func. I II
More informationLED Driver Linear / area fixed output
Driver LC 50W 100 400mA flexc lp EXC EXCITE series Product description Built-in constant current LED Driver Dimmable via ready2mains Gateway Dimming range 13 100 % (Depending on load. For details refer
More informationLED Driver Linear / area fixed output
Driver LC 75W 900 1800mA flexc lp EXC EXCITE series Product description Built-in constant current LED Driver Dimmable via ready2mains Gateway Dimming range 10 100 % (Depending on load. For details refer
More informationPHOENIX CONTACT - 01/2007
Uninterruptible power supply INTERFACE Data Sheet 103123_00_en PHOENIX CONTACT - 01/2007 Description Especially compact and easy-to-use, the new MINI-DC-UPS/ 24 DC/2 is a combination of the power supply
More informationMINI MCR-SL-PT100-UI-200
Configurable temperature transducer for PT00 INTERFACE Data sheet 078_en_0 PHOENIX CONTACT 00-0-5 Description The MINI MCR-SL-PT00-UI-00... is a configurable -way isolated temperature transducer. It is
More informationOperating Instructions VEGAMET 381
Operating Instructions VEGAMET 381 in out Contents Contents 1 About this document... 4 1.1 Function... 4 1.2 Target group... 4 1.3 Symbolism used... 4 2 For your safety... 6 2.1 Authorised personnel...
More informationQUINT-PS/ 1AC/24DC/ 5
Extract from the online catalog QUINT-PS/ 1AC/24DC/ 5 Order No.: 2866750 DIN rail power supply unit 24 V DC/5 A, primary switched-mode, 1- phase. The SFB technology (Selective Fuse Breaking Technology)
More informationLED Driver Linear / area fixed output
Driver LC 69W 35-5mA flexc lp ANCED series Product description Built-in constant current LED Driver New version DC operating with EL marking Adjustable output current between 35 and 5 ma Max. output power
More informationLED Driver Linear / area fixed output
Driver LC 7W 5-35mA flexc lp ANCED series Product description Built-in constant current LED Driver New version DC operating with EL marking Adjustable output current between 5 and 35 ma Max. output power
More informationSwitching relay CT-IRS with 1, 2 or 3 c/o contacts Data sheet
1SVR 430 221 F7300 2 1 3 Characteristics Switching relay ON-delay approx. 10 ms 1, 2 or 3 c/o contacts Switching relay with gold-plated contacts Width 22.5 mm Approvals e f GOST CCC CT-IRS 1 U/R: green
More informationBargraph for quick range overview The digital indicators provide a bargraph in addition to the digital display. This gives you all information
Loop-Powered Digital Indicators 830 Loop-Powered Process Indicator The 830 loop-powered digital indicators are universally applicable. The range (either 0 to 20 ma or 4 to 20 ma) is simply selected via
More informationTest devices and Multifunction timer relay
Test devices and Multifunction timer relay VARIOTEST ROTATEST CSG420 Test devices Industries VARIOTEST The Condor-VARIOTEST is a universal test instrument featuring acoustic signals for: P. 145 Testing
More informationProfi le PF. Contents. PF General data 106 Analog interface 108 IO-Link V Floating magnet 112 Captive magnet 114
Contents PF 106 Analog interface 108 IO-Link V1.1 110 Floating 112 Captive 114 www.balluff.com 105 Low-profile The robust design, high degree of protection and simple installation of Balluff Micropulse
More informationUser s Guide. 600A True RMS AC/DC Clamp Meter. Model 38389
User s Guide 600A True RMS AC/DC Clamp Meter Model 38389 Safety International Safety Symbols This symbol, adjacent to another symbol or terminal, indicates the user must refer to the manual for further
More informationElectronic timer CT-AHS OFF-delayed with 2 c/o contacts Data sheet
2CDC 251 113 F0004 CT-AHS 1 7 2 6 5 4 8 3 1 10 selectable time ranges, from 0.05 s to 300 h 2 Potentiometer with direct reading scale for the fine adjustment of the time delay 3 Sliding switch to set the
More informationLED Driver Compact fixed output
Driver LC 100W 1100 2100mA flexc C EXC EXCITE series Product description Constant current LED Driver Dimmable via ready2mains Gateway Dimming range 15 100 % (Depending on load. For details refer to chapter
More informationSR2A201BD compact smart relay Zelio Logic - 20 I O - 24 V DC - no clock - display
Characteristics compact smart relay Zelio Logic - 20 I O - 24 V DC - no clock - display Main Range of product Product or component type Complementary Local display Number or control scheme lines Cycle
More informationRM4TA32 three-phase network control relay RM4-T - range V
Characteristics three-phase network control relay RM4-T - range 380..500 V Complementary [Us] rated supply voltage Output contacts Main Range of product Product or component type Relay type Product specific
More informationRM4JA01F current measurement relay RM4-J - range ma V AC
Characteristics current measurement relay RM4-J - range 3..1000 ma - 110..130 V AC Main Range of product Product or component type Relay type Relay name Relay monitored parameters Power consumption in
More informationTM3AI4 module TM3-4 analog inputs
Characteristics module TM3-4 analog inputs Main Range of product Product or component type Range compatibility Analogue input number 4 Analogue input type Complementary Analogue input resolution Permissible
More informationLED Driver Linear / area fixed output
Driver C 38W 5-7mA flexc lp ACED series Product description Built-in constant current ED Driver Adjustable output current between 5 and 7 ma Max. output power 38 W Up to 85 % efficiency ominal life-time
More informationElectronic timer CT-EAS ON-delayed and OFF-delayed with 1 c/o contact Data sheet
2CDC 251 116 F0004 1 5 2 4 3 6 Characteristics Single-function ON-delay and OFF-delay timer One device includes 10 time ranges, from 0.05 s to 300 h, for the adjustment of the time delay Remote potentiometer
More informationDINALOG A 96 x 24. Programmable quasi-analogue bar graph meters. Technical characteristics DINALOG A 96 x 24
Bar graph displays For process control, automation, and laboratory applications Current, voltage, resistance, frequency and temperature Up to 0.5% resolution DINALOG A 96 x 24 Programmable quasi-analogue
More informationAutoranging True RMS Multimeter User Manual
Autoranging True RMS Multimeter User Manual Please read this manual before switching the unit on. Important safety information inside. Contents Page 1. Safety Information... 4 2. Safety Symbols... 5 3.
More informationEM2020 Selectable AC transducer A (UK)
Installation and start up instructions EM2020 Selectable AC transducer 4189300016A (UK) Watt or var transducer Supply and measuring voltage up to 690V Configuration via PC-interface possible FAGET 35 mm
More informationMeasuring transducers MI4x0 series Programmable transducers for RTD sensors MI450
Measuring transducers MI4x0 series Programmable transducers for RTD sensors MI450 o Measuring of resistance of RTD sensors (Pt100, Pt1000, Ni100, Cu10,...) o Accuracy class up to: 0.5 o Programmable input
More informationDS5000-IBFS. 5kA rms - 8kA DC Fluxgate current transducer. Features. Description. Application. Precision Innovation /
5kA rms - 8kA DC Fluxgate current transducer Features DC 8000A AC 5000A rms Maximum gain error DC to 1kHz - 0.1% Transducer core optimized for high level of immunity against external magnetic fields Operating
More informationPSM-ME-RS232/TTY-P Interface converter for RS-232 to TTY transmission systems
Interface converter for RS- to transmission systems. Short Description The rail-mountable and compact interface converters have been designed especially for industrial use in the switch cabinet or switch
More informationVEO. V2ZR V AC/DC Art.Nr.: V2ZR10P V AC/DC Art.Nr.: TECHNICAL DATA
Off-Delay 10 time ranges Supply voltage 24-240V AC/DC 1 change-over contact Width 22,5 mm Control elements Fine adjustment Setting of time range Status indication LED U/t: Supply voltage LED R: Relay status
More informationDisplays Transducers. Displays and transducers
JJ Displays JJ Transducers Displays and transducers DS_Displays_and_transducers 06/2016 225 Displays and transducers Our electronic devices for flow and volume measurement are suitable for all SIKA flow
More informationRE17LAMW on-delay timing relay - 1 s..100 h V AC/DC - solid state output
Characteristics on-delay timing relay - 1 s..100 h - 24..240 V AC/DC - solid state output Complementary Control type Voltage range Main Range of product Product or component type Discrete output type Width
More informationRE48ATM12MW on-delay timing relay s..300 h V AC - 2 OC
Characteristics on-delay timing relay - 0.02 s..300 h - 24..240 V AC - 2 OC Complementary Product front plate size Control type Housing material Main Range of product Product or component type Electrical
More informationMINI-PS AC/10-15DC/8
Primary-Switched Power Supply, Narrow Design Data Sheet 08/2004 MINI POWER provides: An extra narrow design, with widths of 22.5 mm, 45 mm, and 67.5 mm (0.886, 1.772, and 2.657 in.) Global use due to a
More informationModel A Mini AC/DC Clamp Meter. User's Guide
Model 380950 80A Mini AC/DC Clamp Meter User's Guide Introduction Congratulations on your purchase of the Extech 80A Mini AC/DC Clamp Meter. The Model 380950 measures AC/DC Current, AC/DC Voltage, Resistance,
More informationRM35UB3. Product data sheet Characteristics. voltage control relay RM35-U - range V AC. Main. Complementary
Characteristics voltage control relay RM35-U - range 194..528 V AC Main Range of product Product or component type Relay type Product specific application Relay name Relay monitored parameters Time delay
More informationSR2B121BD compact smart relay Zelio Logic - 12 I O - 24 V DC - clock - display
Characteristics compact smart relay Zelio Logic - 12 I O - 24 V DC - clock - display Main Range of product Product or component type Zelio Logic Compact smart relay Complementary Local display Number or
More informationRE7YA12BU. Main. Contacts type and composition Component name Time delay type. 24 V AC/DC at 50/60 Hz V AC/DCat 50/60 Hz
Product datasheet Characteristics RE7YA12BU Main Range of product Product or component type Contacts type and composition Component name Time delay type Time delay range Zelio Time Industrial timing relay
More informationSUBJECT TO CHANGE WITHOUT NOTICE
Transducers & Isolators www.sifamtinsley.co.uk Multifunction Meters Transducers & Isolators Temperature Controllers Converters & Recorders Digital Panel Meters Current Transformers Analogue Panel Meters
More informationGX SERIES. Cylindrical Compact Inductive Proximity Sensor Amplifier Built-in. Robust enclosure and flexible cable types are also available
8 Cylindrical Compact Inductive Proximity SERIES Related Information General terms and conditions... F-7 Glossary of terms... P.86~ selection guide... P.757~ General precautions... P.05 PHOTO PHOTO Conforming
More informationTM3TM3 module TM3-2 temperature inputs and 1 analog output
Characteristics module TM3-2 temperature inputs and 1 analog output Main Range of product Product or component type Range compatibility Analogue input number 2 Analogue input type Analogue output number
More information