1993 SPECIFICATIONS CSJ , ETC. & SPECIAL SPECIFICATION ITEM 6132 ARTERIAL TRAFFIC MANAGEMENT SYSTEM

Size: px
Start display at page:

Download "1993 SPECIFICATIONS CSJ , ETC. & SPECIAL SPECIFICATION ITEM 6132 ARTERIAL TRAFFIC MANAGEMENT SYSTEM"

Transcription

1 1993 SPECIFICATIONS CSJ , ETC. & DESCRIPTION SPECIAL SPECIFICATION ITEM 6132 ARTERIAL TRAFFIC MANAGEMENT SYSTEM THIS ITEM DESCRIBES THE OPERATION AND INSTALLATION OF AN ARTERIAL TRAFFIC MANAGEMENT SYSTEM (ATMS). 2.0 ATMS OPERATION ATMS IS A NONPROPRIETARY, DISTRIBUTED PROCESSING TRAFFIC SIGNAL SYSTEM. THE LOCAL CONTROL UNIT (LCU) IS HOUSED IN A CABINET WITH THE NEMA TRAFFIC SIGNAL CONTROLLER. THROUGH THE COMMON BACKPANEL CONNECTION, THE LCU SETS THE CYCLE LENGTH, SPLITS, PHASE SEQUENCE, AND OFFSET FOR THE INTERSECTION. THE SYSTEM CONTROL UNIT (SCU) POLLS THE LCUS FOR STATUS AND DETECTOR DATA, SELECTS THE APPROPRIATE TIMING PLAN, AND DIRECTS THE LCUS TO IMPLEMENT THE TIMING PLAN. THE MANAGER CONTROL UNIT (MCU) PROVIDES THE USER INTERFACE FOR THE ATMS. ALL SOFTWARE FOR THE LCU, SCU, AND MCU HAS BEEN DEVELOPED BY THE DEPARTMENT. 3.0 ATMS INSTALLATION AFTER ALL EQUIPMENT HAS BEEN INSTALLED IN THE FIELD AND HAS PASSED ALL CONTRACTOR CONDUCTED TESTS, THE DEPARTMENT WILL INSTALL THE DATA COMMUNICATIONS TEST SOFTWARE IN THE SCUS AND LCUS AND WILL CONDUCT THE DATA COMMUNICATIONS TESTS AS SPECIFIED ON THE PLANS. AFTER COMPLETION OF THE DATA COMMUNICATIONS TESTS, THE DEPARTMENT WILL INSTALL THE ATMS SOFTWARE IN THE MCUS, SCUS AND LCUS. 4.0 MISCELLANEOUS ITEMS THE FOLLOWING ITEMS SHALL BE FURNISHED: 4.1 LOCAL CONTROL UNIT POWER CABLES DESCRIPTION THE LCU POWER CABLE MATES WITH AN AMP RECEPTACLE LOADED WITH FIVE (5) OUT OF NINE (9) POSSIBLE AMP PIN CONTACTS. THE LCU POWER CABLE SHALL CONSIST OF AN AMP PLUG, WITH MATCHING CABLE CLAMP, AND PARTIALLY LOADED WITH FIVE (5) AMP SOCKET CONTACTS ATTACHED TO 18 AWG STRANDED WIRE. EACH INDIVIDUAL WIRE SHALL HAVE COLOR CODED INSULATION AS INDICATED BELOW

2 PIN INSULATION NUMBER COLOR SIGNAL 1 BLACK 120 V AC 2 WHITE 120 V AC COMMON 3 GREEN 120 V AC EARTH GROUND 7 RED 24 V DC 8 BLUE 24 V DC GROUND INSTALLATION ONE LCU POWER CABLE SHALL BE FURNISHED AND INSTALLED IN EACH SIGNAL CONTROLLER CABINET AS SHOWN ON THE PLANS. THE WIRES SHALL BE TERMINATED TO BUS BARS OR TO TERMINALS ON THE FRONT OF THE BACKPANEL AS APPROPRIATE. THE CONNECTIONS SHALL BE WITH FORKED SPADE LUGS OR OTHERWISE AS NEEDED. EACH INDIVIDUAL WIRE SHALL BE CUT TO THE LENGTH REQUIRED TO REACH THE POINT AT WHICH IT IS TO BE CONNECTED. THERE SHALL BE A MINIMUM OF SIX (6) FEET OF CABLE FROM THE MOUNTING POINT ON THE BACKPANEL TO THE CONNECTOR. AFTER ALL WIRES HAVE BEEN CONNECTED, THE LCU POWER CABLE SHALL BE NEATLY BUNDLED. SEE THE ATMS LCU CABINET INTERCONNECTIONS PLAN SHEET FOR WIRING DETAILS ADDITIONAL TESTS ADDITIONAL LCU POWER CABLES SHALL BE PROVIDED IF CALLED FOR IN THE PLANS DOCUMENTATION FIVE WIRING DIAGRAMS AND PARTS LISTS FOR THE LCU POWER CABLES SHALL BE PROVIDED. 4.2 LOCAL CONTROL UNIT SIGNAL CABLES DESCRIPTION THE LCU SIGNAL CABLE MATES WITH AN AMP RECEPTACLE LOADED WITH AMP SOCKET CONTACTS. THE LCU SIGNAL CABLE SHALL CONSIST OF AN AMP PLUG, WITH MATCHING CABLE CLAMP, FULLY LOADED WITH FIFTY-SEVEN (57) AMP PIN CONTACTS ATTACHED TO 22 AWG STRANDED WIRE INSTALLATION FOUR LCU SIGNAL CABLES SHALL BE FURNISHED AND INSTALLED IN EACH SIGNAL CONTROLLER CABINET AS SHOWN ON THE PLANS. THE CABLES SHALL BE TERMINATED ON THE FRONT OF THE SIGNAL CONTROLLER CABINET BACKPANEL USING FORKED SPADE LUG TERMINALS. EACH INDIVIDUAL WIRE THAT IS TERMINATED ON THE BACKPANEL SHALL BE CUT TO THE LENGTH REQUIRED TO REACH THE SPECIFIC TERMINAL TO WHICH IT IS TO BE CONNECTED. THERE SHALL BE A MINIMUM OF SIX (6) FEET OF CABLE FROM THE MOUNTING POINT ON THE BACKPANEL TO THE CONNECTOR. THE CONNECTED WIRES SHALL BE NEATLY BUNDLED. WIRES WHICH ARE NOT TERMINATED SHALL BE LABELED WITH PIN NUMBERS, BE A MINIMUM OF TEN (10) FEET IN LENGTH AND NEATLY BUNDLED. EACH CABLE BUNDLE SHALL BE LABELED WITH THE NAME OF THE SIGNAL CABLE TO WHICH IT BELONGS. SEE THE ATMS LCU CABINET INTERCONNECTIONS PLAN SHEET FOR WIRING

3 DETAILS. NOTE THAT THE PIN CORRESPONDING TO THE KEYING PLUG MUST BE REMOVED ON EACH CABLE. CABLES SHOULD BE NUMBERED ONE THROUGH FOUR AT THE CONNECTOR END ADDITIONAL CABLES ADDITIONAL LCU SIGNAL CABLES SHALL BE PROVIDED IF CALLED FOR IN THE PLANS DOCUMENTATION FIVE WIRING DIAGRAMS AND PARTS LISTS FOR THE LCU SIGNAL CABLES SHALL BE PROVIDED. 4.3 SCU COMMUNICATIONS INTERFACE PANEL DESCRIPTION THE SCU COMMUNICATIONS INTERFACE PANEL SHALL CONSIST OF AN ENCLOSURE CONTAINING INDIVIDUALLY REPLACEABLE LIGHTNING PROTECTION MODULES FOR EACH PAIR OF WIRES IN A 50 PAIR CABLE. THE ENCLOSURE SHALL PROVIDE A 66M TYPE TERMINATION PANEL FOR FIELD TERMINATION, TWO (2) RJ21 CONNECTORS FOR CONNECTION TO THE SCU, AND A REMOVABLE OR HINGED COVER. INSERTION OF A PROTECTION MODULE SHALL AUTOMATICALLY PROVIDE A GROUND CONNECTION AND ESTABLISH CONTINUITY BETWEEN THE FIELD WIRING AND THE CORRESPONDING RJ21 PINS. EACH PROTECTION CIRCUIT SHALL MEET THE FOLLOWING REQUIREMENTS: 1. A GAS DISCHARGE TUBE SHALL BE PROVIDED FOR PRIMARY SURGE PROTECTION. 2. SECONDARY PROTECTION SHALL BE PROVIDED BY EITHER HEAT COILS OR SILICON TRANSIENT PROTECTION DEVICES. 3. EACH CIRCUIT SHALL OPERATE WITH ANALOG LINE VOLTAGES BETWEEN -12 AND + 12 VOLTS, AND LESS THAN 0.5 DB INSERTION LOSS AT DATA TRANSMISSION RATES UP TO 19,200 BITS PER SECOND. 4. EACH CIRCUIT SHALL PROTECT AGAINST SURGE TRANSIENTS NOT EXCEEDING 10 KV AND 2.5 KA. 5. CLAMPING OR ARCING VOLTAGE LEVELS SHALL BE AT 24 VOLTS INSTALLATION A SCU COMMUNICATIONS INTERFACE PANEL SHALL BE FURNISHED AND INSTALLED AT EACH SCU CONSOLE. THE COMMUNICATIONS CABLE SHALL BE TERMINATED ON THIS PANEL AS SHOWN ON THE PLANS. TWO (2) 30 FOOT CABLES SHALL BE PROVIDED WITH RJ21 CONNECTORS MATING TO THE SCU CONSOLE REAR COMMUNICATIONS CONNECTOR PANEL AND TO THE SCU COMMUNICATIONS INTERFACE PANEL DOCUMENTATION A WIRING DIAGRAM AND PARTS LIST SHALL BE PROVIDED FOR EACH SCU COMMUNICATIONS INTERFACE PANEL

4 4.4 LOCAL LIGHTNING PROTECTION MODULE DESCRIPTION THE LOCAL LIGHTNING PROTECTION MODULE SHALL CONSIST OF A SEALED UNIT CONTAINING EIGHT PROTECTION CIRCUITS, EACH TERMINATED BY A PAIR OF NO. 6 SCREW TERMINALS ON OPPOSITE ENDS OF THE MODULE. AN ADDITIONAL NO. 6 SCREW TERMINAL SHALL BE PROVIDED ON EACH END FOR CONNECTION TO AN EARTH GROUND TERMINAL. EACH PROTECTION CIRCUIT SHALL MEET THE FOLLOWING REQUIREMENTS: 1. A GAS DISCHARGE TUBE SHALL BE PROVIDED FOR PRIMARY SURGE PROTECTION. 2. A SILICON TRANSIENT PROTECTOR SHALL BE USED TO ESTABLISH A LOW LEVEL CLAMPING VOLTAGE. 3. EACH CIRCUIT SHALL OPERATE WITH ANALOG LINE VOLTAGES BETWEEN -12 AND + 12 VOLTS, AND LESS THAN 0.5 DB INSERTION LOSS AT DATA TRANSMISSION RATES UP TO 19,200 BITS PER SECOND. 4. EACH CIRCUIT SHALL PROTECT AGAINST SURGE TRANSIENTS NOT EXCEEDING 10 KV AND 2.5 KA. 5. EACH CIRCUIT SHALL BE CLAMPED AT 24 VOLTS, LINE-TO-GROUND. 6. THE ANALOG LINE VOLTAGE SHALL NOT EXCEED THE CLAMPING VOLTAGE FOR MORE THAN 10 NANOSECONDS DOCUMENTATION FIVE COPIES OF THE WIRING DIAGRAM AND PARTS LIST FOR THE LOCAL LIGHTNING PROTECTION MODULE SHALL BE PROVIDED CABLE LOCAL COMMUNICATIONS INTERFACE PANEL DESCRIPTION THE 2 CABLE LOCAL COMMUNICATIONS INTERFACE PANEL PROVIDES INTERCONNECTION POINTS FOR TWO 50 PAIR OR TWO 25 PAIR COMMUNICATIONS CABLES, AND LIGHTNING PROTECTION FOR THE FIELD EQUIPMENT. THE 2 CABLE LOCAL COMMUNICATIONS INTERFACE PANEL SHALL MEET THE FOLLOWING REQUIREMENTS: 1. THE PANEL SHALL BE CONSTRUCTED OF 1/8" ALUMINUM, AND SHALL NOT EXCEED 12" IN ANY DIMENSION. 2. THE PANEL SHALL CONTAIN A 66M BLOCK WITH 50 PAIRS OF DOUBLE CLIPS, TYPE SIEMON 842 OR EQUIVALENT, UNWIRED. 3. THE PANEL SHALL CONTAIN A LOCAL LIGHTNING PROTECTION MODULE (LPM). 4. THE PANEL SHALL CONTAIN A STANDARD TWO CONDUCTOR, QUARTER INCH, PHONE JACK THAT SHALL MATE WITH THE VOICE POWERED HEADSET PLUG. THE JACK SHALL BE ELECTRICALLY INSULATED FROM THE PANEL. 5. THE PANEL SHALL CONTAIN A THREE INCH HORIZONAL SLOT IN EACH CORNER TO ACCOMMODATE 0.25 INCH MOUNTING BOLTS

5 6. THE PANEL SHALL PROVIDE SPACE ON EACH SIDE OF THE 66M BLOCK FOR A 50 PAIR CABLE. A CLAMP OR STRAP SHALL BE PROVIDED TO SECURELY HOLD EACH CABLE IN PLACE ON THE PANEL INSTALLATION ONE 2 CABLE LOCAL COMMUNICATIONS INTERFACE PANEL SHALL BE FURNISHED AND INSTALLED IN EACH SIGNAL CONTROLLER CABINET AS SHOWN IN THE PLANS. THE FOLLOWING STEPS SHALL BE FOLLOWED IN INSTALLING THE 2 CABLE LOCAL COMMUNICATIONS INTERFACE PANEL. 1. A TWO (2) PAIR 66M CLIP TO RJ11 ADAPTER SHALL BE INSTALLED ON THE 66M BLOCK IN THE CORRESPONDING POSITION FOR THE CABINET PAIR ASSIGNMENT AS SHOWN IN THE PLANS. A MODULAR FOUR WIRE CABLE SHALL CONNECT THIS ADAPTER TO THE LPM. THE LENGTH OF THE CABLE SHALL PERMIT THE ADAPTER TO BE MOVED TO ANY POSITION ON THE 66M BLOCK. EACH INDIVIDUAL WIRE OF THE CABLE SHALL HAVE COLOR CODED INSULATION AND SHALL BE CONNECTED AS INDICATED BELOW. 2 PAIR 66M INPUT TO LPM CLIP TO RJ11 RJ11 PIN INSULATION TERMINAL ADAPTER SLOT NUMBER COLOR NUMBER 1 2 BLACK RED GREEN YELLOW 4 2. A ONE (1) PAIR 66M CLIP TO RJ11 ADAPTER SHALL BE INSTALLED ON THE 66M BLOCK IN THE CORRESPONDING POSITION FOR THE VOICE PAIR ASSIGNMENT AS SHOWN ON THE PLANS. A MODULAR CABLE SHALL CONNECT THIS ADAPTER TO THE LPM. THE LENGTH OF THE CABLE SHALL PERMIT THE ADAPTER TO BE MOVED TO ANY POSITION ON THE 66M BLOCK. EACH INDIVIDUAL WIRE OF THE CABLE SHALL HAVE COLOR CODED INSULATION AND SHALL BE CONNECTED AS INDICATED BELOW. 1 PAIR 66M INPUT TO LPM CLIP TO RJ11 RJ11 PIN INSULATION TERMINAL ADAPTER SLOT NUMBER COLOR NUMBER 1 3 RED GREEN 6 3. A FOUR (4) WIRE CABLE, SEVEN (7) FEET IN LENGTH, SHALL BE INSTALLED ON THE LPM TO CONNECT THE TWO PAIR 66M CLIP TO RJ11 ADAPTER TO THE LOCAL LIMITED DISTANCE MODEM. THE FREE END SHALL HAVE TERMINATIONS APPROPRIATE FOR THE MODEM'S ANALOG INTERFACE CONNECTORS. EACH INDIVIDUAL WIRE OF THE CABLE SHALL HAVE COLOR CODED INSULATION AND SHALL BE CONNECTED AS INDICATED BELOW. INSULATION OUTPUT FROM LPM MODEM COLOR TERMINAL NUMBER CONNECTION BLACK 1 LCU RECEIVED DATA RED 2 LCU RECEIVED DATA GREEN 3 LCU TRANSMIT DATA YELLOW 4 LCU TRANSMIT DATA

6 4. A MODULAR CABLE SHALL BE INSTALLED ON THE LPM TO CONNECT THE ONE PAIR 66M CLIP TO RJ11 ADAPTER TO THE VOICE JACK. EACH INDIVIDUAL WIRE OF THE CABLE SHALL HAVE COLOR CODED INSULATION AND SHALL BE CONNECTED AS INDICATED BELOW. INSULATION OUTPUT FROM LPM COLOR TERMINAL NUMBER CONNECTION RED 5 VOICE JACK GREEN 6 VOICE JACK 5. THE PANEL SHALL BE ELECTRICALLY CONNECTED TO THE LPM GROUND TERMINAL. A NO. 10 AWG BARE SOLID COPPER WIRE OF APPROPRIATE LENGTH SHALL BE SECURED TO EITHER THE LPM GROUND TERMINAL OR TO THE PANEL ITSELF, AND TO THE AC GROUND BUS BAR IN THE CABINET. 6. PAIRS 1 THROUGH 25 OF THE COMMUNICATIONS CABLE INCOMING FROM THE DIRECTION OF THE SYSTEM CONTROL UNIT LOCATION SHALL BE SECURED ON THIS PANEL ON THE LEFT SIDE OF THE 66M BLOCK AND TERMINATED ON THE FIRST COLUMN OF PINS, COUNTING FROM LEFT TO RIGHT. PAIRS 26 THROUGH 50, IF THEY EXIST, OF THE INCOMIMG COMMUNICATIONS CABLE SHALL BE SECURED ON THE LEFT SIDE OF THE 66M BLOCK AND TERMINATED ON THE THIRD COLUMN OF PINS. PAIRS 1 THROUGH 25 OF THE OUTGOING COMMUNICATIONS CABLE, IF ONE EXISTS, SHALL BE SECURED ON THIS PANEL ON THE RIGHT SIDE OF THE 66M BLOCK AND TERIMINATED ON THE SECOND COLUMN OF PINS. PAIRS 26 THROUGH 50, IF THEY EXIST, OF THE OUTGOING COMMUNICATIONS CABLE SHALL BE SECURED ON THIS PANEL ON THE RIGHT SIDE OF THE 66M BLOCK AND TERMINATED ON THE FOURTH COLUMN OF PINS. 7. EACH COMMUNICATIONS CABLE SHALL BE PERMANENTLY LABELLED NEAR THE TERMINATION POINT ON THIS PANEL WITH THE NAME OF THE INTERSECTION AT WHICH THE OTHER END OF THE COMMUNICATIONS CABLE IS TERMINATED ADDITIONAL PANELS ADDITIONAL 2 CABLE LOCAL COMMUNICATIONS INTERFACE PANELS SHALL BE PROVIDED IF CALLED FOR IN THE PLANS DOCUMENTATION FIVE WIRING DIAGRAMS AND PARTS LISTS FOR THE 2 CABLE LOCAL COMMUNICATIONS INTERFACE PANELS SHALL BE PROVIDED CABLE LOCAL COMMUNICATIONS INTERFACE PANEL DESCRIPTION THE 3 CABLE LOCAL COMMUNICATIONS INTERFACE PANEL PROVIDES INTERCONNECTION POINTS FOR THREE 25 PAIR COMMUNICATIONS CABLES, AND LIGHTNING PROTECTION FOR THE FIELD EQUIPMENT. THE 3 CABLE LOCAL COMMUNICATIONS INTERFACE PANEL SHALL MEET THE FOLLOWING REQUIREMENTS: 1. THE PANEL SHALL BE CONSTRUCTED OF 1/8" ALUMINUM, AND SHALL NOT EXCEED 12" IN ANY DIMENSION. 2. THE PANEL SHALL CONTAIN A 66M BLOCK WITH 25 PAIRS OF QUADRUPLE CLIPS, TYPE SIEMON 569 OR EQUIVALENT, UNWIRED

7 3. THE PANEL SHALL CONTAIN A LOCAL LIGHTNING PROTECTION MODULE (LPM). 4. THE PANEL SHALL CONTAIN A STANDARD TWO CONDUCTOR, QUARTER INCH, PHONE JACK THAT SHALL MATE WITH THE VOICE POWERED HEADSET PLUG. THE JACK SHALL BE ELECTRICALLY INSULATED FROM THE PANEL. 5. THE PANEL SHALL CONTAIN A THREE INCH HORIZONAL SLOT IN EACH CORNER TO ACCOMMODATE 0.25 INCH MOUNTING BOLTS. 6. THE PANEL SHALL PROVIDE SPACE ON EACH SIDE OF THE 66M BLOCK FOR A 50 PAIR CABLE. A CLAMP OR STRAP SHALL BE PROVIDED TO SECURELY HOLD EACH CABLE IN PLACE ON THE PANEL INSTALLATION ONE 3 CABLE LOCAL COMMUNICATIONS INTERFACE PANEL SHALL BE FURNISHED AND INSTALLED IN EACH SIGNAL CONTROLLER CABINET AS SHOWN IN THE PLANS. THE FOLLOWING STEPS SHALL BE FOLLOWED IN INSTALLING THE 3 CABLE LOCAL COMMUNICATIONS INTERFACE PANEL. 1. A TWO (2) PAIR 66M CLIP TO RJ11 ADAPTER SHALL BE INSTALLED ON THE 66M BLOCK IN THE CORRESPONDING POSITION FOR THE CABINET PAIR ASSIGNMENT AS SHOWN IN THE PLANS. A MODULAR FOUR WIRE CABLE SHALL CONNECT THIS ADAPTER TO THE LPM. THE LENGTH OF THE CABLE SHALL PERMIT THE ADAPTER TO BE MOVED TO ANY POSITION ON THE 66M BLOCK. EACH INDIVIDUAL WIRE OF THE CABLE SHALL HAVE COLOR CODED INSULATION AND SHALL BE CONNECTED AS INDICATED BELOW. 2 PAIR 66M INPUT TO LPM CLIP TO RJ11 RJ11 PIN INSULATION TERMINAL ADAPTER SLOT NUMBER COLOR NUMBER 1 2 BLACK RED GREEN YELLOW 4 2. A ONE (1) PAIR 66M CLIP TO RJ11 ADAPTER SHALL BE INSTALLED ON THE 66M BLOCK IN THE CORRESPONDING POSITION FOR THE VOICE PAIR ASSIGNMENT AS SHOWN ON THE PLANS. A MODULAR CABLE SHALL CONNECT THIS ADAPTER TO THE LPM. THE LENGTH OF THE CABLE SHALL PERMIT THE ADAPTER TO BE MOVED TO ANY POSITION ON THE 66M BLOCK. EACH INDIVIDUAL WIRE OF THE CABLE SHALL HAVE COLOR CODED INSULATION AND SHALL BE CONNECTED AS INDICATED BELOW. 1 PAIR 66M INPUT TO LPM CLIP TO RJ11 RJ11 PIN INSULATION TERMINAL ADAPTER SLOT NUMBER COLOR NUMBER 1 3 RED GREEN 6 3. A FOUR (4) WIRE CABLE, SEVEN (7) FEET IN LENGTH, SHALL BE INSTALLED ON THE LPM TO CONNECT THE TWO PAIR 66M CLIP TO RJ11 ADAPTER TO THE LOCAL LIMITED DISTANCE MODEM. THE FREE END SHALL HAVE TERMINATIONS APPROPRIATE FOR THE MODEM'S ANALOG INTERFACE CONNECTORS. EACH INDIVIDUAL WIRE OF THE CABLE SHALL HAVE COLOR CODED INSULATION AND SHALL BE CONNECTED AS INDICATED BELOW

8 INSULATION OUTPUT FROM LPM MODEM COLOR TERMINAL NUMBER CONNECTION BLACK 1 LCU RECEIVED DATA RED 2 LCU RECEIVED DATA GREEN 3 LCU TRANSMIT DATA YELLOW 4 LCU TRANSMIT DATA 4. A MODULAR CABLE SHALL BE INSTALLED ON THE LPM TO CONNECT THE ONE PAIR 66M CLIP TO RJ11 ADAPTER TO THE VOICE JACK. EACH INDIVIDUAL WIRE OF THE CABLE SHALL HAVE COLOR CODED INSULATION AND SHALL BE CONNECTED AS INDICATED BELOW. INSULATION OUTPUT FROM LPM COLOR TERMINAL NUMBER CONNECTION RED 5 VOICE JACK GREEN 6 VOICE JACK 5. THE PANEL SHALL BE ELECTRICALLY CONNECTED TO THE LPM GROUND TERMINAL. A NO. 10 AWG BARE SOLID COPPER WIRE OF APPROPRIATE LENGTH SHALL BE SECURED TO EITHER THE LPM GROUND TERMINAL OR TO THE PANEL ITSELF, AND TO THE AC GROUND BUS BAR IN THE CABINET. 6. PAIRS 1 THROUGH 25 OF THE COMMUNICATIONS CABLE INCOMING FROM THE DIRECTION OF THE SYSTEM CONTROL UNIT LOCATION SHALL BE SECURED ON THIS PANEL ON THE LEFT SIDE OF THE 66M BLOCK AND TERMINATED ON THE FIRST COLUMN OF PINS, COUNTING FROM LEFT TO RIGHT. PAIRS 1 THROUGH 25 OF THE FIRST OUTGOING COMMUNICATIONS CABLE SHALL BE SECURED ON THIS PANEL ON THE RIGHT SIDE OF THE 66M BLOCK AND TERIMINATED ON THE SECOND COLUMN OF PINS. PAIRS 1 THROUGH 25 OF THE SECOND OUTGOING COMMUNICATIONS CABLE SHALL BE SECURED ON THIS PANEL ON THE RIGHT SIDE OF THE 66M BLOCK AND TERMINATED ON THE THIRD COLUMN OF PINS. 7. EACH COMMUNICATIONS CABLE SHALL BE PERMANENTLY LABELLED NEAR THE TERMINATION POINT ON THIS PANEL WITH THE NAME OF THE INTERSECTION AT WHICH THE OTHER END OF THE COMMUNICATIONS CABLE IS TERMINATED ADDITIONAL PANELS ADDITIONAL 3 CABLE LOCAL COMMUNICATIONS INTERFACE PANELS SHALL BE PROVIDED IF CALLED FOR ON THE PLANS DOCUMENTATION FIVE WIRING DIAGRAMS AND PARTS LISTS FOR THE 3 CABLE LOCAL COMMUNICATIONS INTERFACE PANELS SHALL BE PROVIDED. 4.7 VOICE POWERED COMMUNICATIONS HEADSET DESCRIPTION THE VOICE POWERED COMMUNICATIONS HEADSET SHALL FIT OVER A PERSON'S HEAD AND INCLUDE ACOUSTIC BOOM AND AN EXTENSION CORD. THE HEADSET SHALL MEET THE FOLLOWING REQUIREMENTS: 1. THE HEADSET SHALL ALLOW HANDS-FREE OPERATION

9 2. THE HEADSET SHALL ALLOW THE BOOM TO BE WORN ON EITHER SIDE OF THE HEAD. 3. THE HEAD CORD AND EXTENSION SHALL BE A MINIMUM OF TEN (10) FEET IN LENGTH. 4. THE HEADSET SHALL TERMINATE INTO A STANDARD TWO CONDUCTOR, QUARTER INCH, PHONE PLUG THAT WILL MATE WITH THE CORRESPONDING VOICE POWERED HEADSET JACK ON THE LOCAL COMMUNICATIONS INTERFACE PANEL IN EACH CABINET. 5. CLEAR COMMUNICATIONS SHALL BE POSSIBLE WITH ENVIRONMENTAL NOISE LEVELS UP TO 100 DBA, AND THE HEADSET SHALL HAVE A NOISE REDUCTION RATING (NRR) OF AT LEAST 16 DB INSTALLATION THE NUMBER OF HEADSETS PROVIDED SHALL BE AS SHOWN ON THE PLANS. 4.8 EIA RS-232C SERIAL CABLES DESCRIPTION THE EIA RS-232C SERIAL CABLES SHALL MEET THE FOLLOWING REQUIREMENTS: 1. THE CABLE SHALL BE TEN (10) FEET IN LENGTH. 2. THE CABLE SHALL BE CONSTRUCTED WITH 24 AWG CONDUCTOR SURROUNDED BY AN ALUMINUM FOIL SHIELD, JACKETED IN PVC AND TERMINATED WITH DIE CAST ZINC HOODS AND APPROPRIATE STRAIN RELIEFS. 3. THE CABLE SHALL BE TESTED FOR CONTINUITY AND SHIELDING EFFECTIVENESS. 4. THE CABLE SHALL HAVE MALE DB25 CONNECTORS ON EACH END AND SHALL BE CONFIGURED TO PROVIDE A MALE-TO-MALE, STRAIGHT THROUGH CONNECTION FOR EACH PIN OF THE RS-232C SIGNAL. 5. THE CABLE SHALL BE COMPATIBLE WITH COMPUTER AND COMMUNICATIONS EQUIPMENT. 6. BOTH CONNECTORS SHALL HAVE CAPTIVE JACK SCREWS WITH NO THREADS INSTALLATION THE NUMBER OF CABLES PROVIDED SHALL BE AS SHOWN ON THE PLANS. 4.9 SHIELDED NULL MODEMS DESCRIPTION THE SHIELDED NULL MODEM SHALL MEET THE FOLLOWING REQUIREMENTS: 1. THE MODEM SHALL MAINTAIN THE INTEGRITY OF THE EIA RS-232C CABLES. 2. THE MODEM SHALL BE OF PC BOARD CONSTRUCTION AND SURROUNDED BY A METAL SHELL AND A PVC MOLDED CASE

10 3. THE MODEM SHALL HAVE A MALE AND FEMALE DB25 CONNECTOR. 4. THE MODEM SHALL ADHERE TO THE FOLLOWING WIRING CONFIGURATION: INSTALLATION DEC TYPE CONTACT NO. TO CONTACT NO THE NUMBER OF SHIELDED NULL MODEMS PROVIDED SHALL BE AS SHOWN ON THE PLANS SYSTEM DETECTOR PANEL GENERAL REQUIREMENTS THE SYSTEM DETECTOR PANEL SHALL PROVIDE ALL CONNECTIONS BETWEEN THE DETECTOR LOOPS AND THE DETECTOR AMPLIFIERS, PEDESTRIAN CALL ISOLATION, AND DETECTOR TEST SWITCHES. IT SHALL ALSO PROVIDE FOR ALL CONNECTIONS BETWEEN THE DETECTOR AMPLIFIERS AND EXTERNAL CONTROL UNITS. THE SYSTEM DETECTOR PANEL SHALL MEET THE FOLLOWING REQUIREMENTS: 1. THE PANEL SHALL BE CONSTRUCTED OF 1/8" ALUMINUM. 2. THE PANEL SHALL CONTAIN A THREE INCH HORIZONTAL SLOT IN EACH CORNER TO ACCOMMODATE 0.25 INCH MOUNTING BOLTS. 3. INPUTS FROM THE LOOPS SHALL BE BROUGHT THROUGH POSTED X 5/16 INCH BINDER SCREW TERMINALS. 4. EACH LOOP PAIR SHALL BE PROTECTED BY LIGHTING SURGE SUPPRESSORS PREQUAILFIED FOR USE ON LOOP DETECTOR INPUTS BY THE DEPARTMENTS' TRAFFIC OPERATIONS DIVISION. THE SUPPRESSORS MAY BE MOUNTED EITHER ON THE FRONT OR BEHIND THE PANEL. 5. THE OUTPUTS FROM THE DETECTOR AMPLIFIERS TO EXTERNAL CONTROL UNITS SHALL BE BROUGHT THROUGH POSTED 6-32 X 1/4 INCH BINDER HEAD SCREW TERMINALS WITH REMOVABLE SHORTING BARS INSTALLED. 6. THE PANEL SHALL PROVIDE THE FOLLOWING CONNECTION POINTS AS A MINIMUM FOR SIXTEEN (16) DETECTORS:

11 CONNECTION POINT NO. OF CONNECTION POINTS LOOP OUTPUTS 16, 1 FOR EACH DETECTOR (COLLECTORS) LOOP OUTPUTS 16, 1 FOR EACH DETECTOR (EMITTERS) DATA TRANSMIT 1 DATA RECEIVE 1 RESET 1 EXTERNAL 24V 1 POWER SUPPLY LOOP INPUTS 32, 2 FOR EACH DETECTOR LOGIC GROUND 6 SPARES 6 DELAY INHIBIT 16, 1 FOR EACH DETECTOR CHASSIS GROUND 1 BUS BUS 7. THE LOOP OUTPUTS (EMITTERS) SHALL BE BUSSED TOGETHER WITH INDIVIDUAL CLIPS ON THE FRONT OF THE PANEL. THE EMITTERS SHALL BE STRAPPED ON THE FRONT OF THE PANEL TO A LOGIC GROUND TERMINAL. 8. THE LOGIC GROUND TERMINALS SHALL BE BUSSED ON THE BACK OF THE PANEL WITH A BUS BAR. 9. A CHASSIS GROUND BUS BAR SHALL BE PROVIDED ON THE PANEL AND CONNECTED TO THE CABINET BY AN INSULATED BRAIDED COPPER GROUND STRAP. THE STRAP SHALL BE BONDED TO THE CABINET. 10. AN ON-OFF-MOMENTARY TOGGLE SWITCH SHALL BE PROVIDED FOR EACH DETECTOR CIRCUIT AND PEDESTRIAN PHASE IF APPLICABLE TO PERMIT THE USER TO DISCONNECT THE DETECTOR INPUT FROM THE CONTROL UNIT, OR PERMIT THE USER TO PLACE A CALL TO THE CONTROL UNIT. THE MOMENTARY POSITION SHALL PLACE A CALL TO THE CONTROL UNIT. THE ON POSITION SHALL CONNECT THE DETECTOR TO THE CONTROL UNIT. THE CENTER OFF POSITION SHALL DISCONNECT THE DETECTOR FROM THE CONTROL UNIT. 11. PEDESTRIAN CALLS FROM PUSHBUTTONS SHALL BE OPTICALLY ISOLATED FROM THE CONTROLLER INPUTS USING EXTERNAL SOLID STATE CIRCUITRY MOUNTED ON A PEDESTRIAN ISOLATION CARD INSTALLATION ONE SYSTEM DETECTOR PANEL SHALL BE FURNISHED AND INSTALLED IN THE SIGNAL CONTROLLER CABINETS AS SHOWN ON THE PLANS DOOR SWITCH DESCRIPTION THE DOOR SWITCH SHALL MEET THE FOLLOWING REQUIREMENTS: 1. THE SWITCH SHALL BE A MOMENTARY, PIN-TYPE DOOR SWITCH. 2. THE SWITCH SHALL BE INSTALLED IN THE CABINET OR ON THE DOOR. 3. THE SWITCH SHALL BE CONNECTED TO A TERMINAL SO THAT THE LOCAL CONTROL UNIT DOOR OPEN CONFIRM INPUT IS CONNECTED TO LOGIC GROUND WHEN THE CABINET DOOR IS OPEN

12 INSTALLATION ONE DOOR SWITCH SHALL BE FURNISHED AND INSTALLED IN EACH SIGNAL CONTROLLER CABINET AS SHOWN ON THE PLANS. 5.0 MEASUREMENT AND PAYMENT NO DIRECT MEASUREMENT OR PAYMENT WILL BE MADE FOR THE WORK TO BE DONE OR THE EQUIPMENT TO BE FURNISHED UNDER THIS ITEM, BUT IT WILL BE CONSIDERED SUBSIDIARY TO THE PARTICULAR ITEMS REQUIRED BY THE PLANS AND THE CONTRACT

SPECIAL SPECIFICATION 1864 Pole Mounted Cabinet

SPECIAL SPECIFICATION 1864 Pole Mounted Cabinet 1993 Specifications CSJ s 0924-06-221,etc. & 0924-06-223 SPECIAL SPECIFICATION 1864 Pole Mounted Cabinet 1. Description. This specification describes the minimum acceptable requirements for a weatherproof

More information

STATE OF NEW JERSEY BUREAUS OF ITS ENGINEERING AND SAFETY & DATA DEVELOPMENT DEPARTMENT OF TRANSPORTATION TRENTON, NEW JERSEY 08625

STATE OF NEW JERSEY BUREAUS OF ITS ENGINEERING AND SAFETY & DATA DEVELOPMENT DEPARTMENT OF TRANSPORTATION TRENTON, NEW JERSEY 08625 September 2011 STATE OF NEW JERSEY BUREAUS OF ITS ENGINEERING AND SAFETY & DATA DEVELOPMENT DEPARTMENT OF TRANSPORTATION TRENTON, NEW JERSEY 08625 MATERIAL SPECIFICATIONS FOR WEIGH-IN-MOTION SYSTEM The

More information

Installation Notes TII Model 341 Protector

Installation Notes TII Model 341 Protector Installation Notes TII Model 341 Protector (ATT-IS PEC 32918) for MERLIN Communications System In Range Out of Building (IROB) Station Installation By Trained Technician Only WARNING: Failure to follow

More information

Installing the Cisco AS5400XM Universal Gateway

Installing the Cisco AS5400XM Universal Gateway CHAPTER 3 Installing the Cisco AS5400XM Universal Gateway This chapter guides you through the installation of the Cisco AS5400XM universal gateway and includes the following sections: Setting Up the Chassis,

More information

SPECIAL SPECIFICATION 1252 System Control Unit Console

SPECIAL SPECIFICATION 1252 System Control Unit Console 1993 Specifications CSJ 0924-06-147, etc. SPECIAL SPECIFICATION 1252 System Control Unit Console 1. Description. This Item shall govern for the furnishing and installation of system control unit (SCU)

More information

SPECIAL SPECIFICATION 6717 Local Control Unit

SPECIAL SPECIFICATION 6717 Local Control Unit 1995 Metric CSJ 0038-01-033, Etc. SPECIAL SPECIFICATION 6717 Local Control Unit 1. Description. This item shall govern for the furnishing and installation of local control units in designated field locations

More information

1993 Specifications CSJ SPECIAL SPECIFICATION ITEM Transportation Management Console

1993 Specifications CSJ SPECIAL SPECIFICATION ITEM Transportation Management Console 1993 Specifications CSJ 0598-01-057 1.0 Description SPECIAL SPECIFICATION ITEM 6398 Transportation Management Console This Item shall govern for the furnishing and installation of Transportation Management

More information

ELECTRO-MECH SCOREBOARD CO.

ELECTRO-MECH SCOREBOARD CO. ELECTRO-MECH SCOREBOARD CO. MODEL 2150 SHOT TIMER OWNER S HANDBOOK Thank you for choosing an Electro-Mech Scoreboard for your athletic complex. We are confident that your new shot timer will give many

More information

This Datasheet is for the IC693CBL300. I/O Bus Expansion Cables.

This Datasheet is for the IC693CBL300. I/O Bus Expansion Cables. This Datasheet is for the IC6CBL00 I/O Bus Expansion Cables http://www.qualitrol.com/shop/p-45-ic6cbl00.aspx Provides the wiring diagrams and installation guidelines for this GE Series 0-0 module. For

More information

SECTION PANEL WORK

SECTION PANEL WORK SECTION 13430 PANEL WORK PART 1 GENERAL 1.01 DESCRIPTION A. This section covers requirements for panel work. B. The contract item Panel Work includes, but is not limited to, the following electrical equipment

More information

Target Interface / Construction Compliance Inspection Checklist

Target Interface / Construction Compliance Inspection Checklist A. Targets Quantities meet DD9, applicable TC 5-, and CEHNC Design Guide 0-- Oriented to face firing line or firing positions/points B. Roads-Service, Lanes Number of lanes meets DD 9, applicable TC 5-,

More information

SECTION SURGE PROTECTION DEVICES. A. Section includes Surge Protection Devices for low-voltage power, control, and communication equipment.

SECTION SURGE PROTECTION DEVICES. A. Section includes Surge Protection Devices for low-voltage power, control, and communication equipment. SECTION 26 43 00 SURGE PROTECTION DEVICES PART 1 - GENERAL 1.1 SUMMARY A. Section includes Surge Protection Devices for low-voltage power, control, and communication equipment. 1.2 DEFINITIONS A. ATS:

More information

Target Interface / Construction Compliance Inspection Checklist

Target Interface / Construction Compliance Inspection Checklist A. Targets Quantities meet DD9, applicable TC -, and CEHNC Design Guide 0-- Oriented to face firing line or firing positions/points B. Roads-Service, Lanes Number of lanes meets DD 9, applicable TC -,

More information

Telephony Multi-Taps. 9000T-TP Series

Telephony Multi-Taps. 9000T-TP Series 9000T-TP Series The 9000T-TP series 1 GHz twisted-pair power multi-tap taps off part of its input RF and AC, but lets the rest pass through. It divides the tapped-off signal and power into multiple outputs,

More information

DIN Molded Cable Assemblies

DIN Molded Cable Assemblies DIN 43650 Telephone (973) 586-500 FAX (973) 596-590 DIN 43650 8mm For Solenoid Valve Applications Black PVC Cable & Connector DUAL JUMPED GROUND PINS Molded cable assemblies can be mounted with cable exiting

More information

Data Cable for GSP-2900 Fixed Satellite Phone. Installation Instructions. Revised July 2004

Data Cable for GSP-2900 Fixed Satellite Phone. Installation Instructions. Revised July 2004 Data Cable for GSP-2900 Fixed Satellite Phone Installation Instructions Revised July 2004 1 This document provides step-by-step instructions enabling the user to install the GSP- 2900 Data Cable Kit. 1.

More information

HyperLink Brand Weatherproof PTZ Camera Lightning and Surge Protector Model: AL-VDP Series

HyperLink Brand Weatherproof PTZ Camera Lightning and Surge Protector Model: AL-VDP Series HyperLink Brand Weatherproof PTZ Camera Lightning and Surge Protector Model: AL-VDP Series Applications Pan-Tilt-Zoom (PTZ) analog video cameras Features Individual protection circuits for analog video

More information

Target Interface / Construction Compliance Inspection Checklist

Target Interface / Construction Compliance Inspection Checklist A. Targets Quantities meet DD9, applicable TC -, and CEHNC Design Guide 0-- Oriented to face firing line or firing positions/points B. Roads-Service, Lanes Number of lanes meets DD 9, applicable TC -,

More information

Connector and Cable Specifications

Connector and Cable Specifications APPENDIX B This appendix describes the pinouts and cabling requirements for the interfaces and cables used on the Cisco ubr925 cable access router. All connectors for these interfaces are on the rear-panel,

More information

Appendix D. EMC Installation Guidelines. Safety Considerations. Ferrite Absorbers and P-Clips. General Product Philosophy

Appendix D. EMC Installation Guidelines. Safety Considerations. Ferrite Absorbers and P-Clips. General Product Philosophy Appendix D EMC Installation Guidelines General Product Philosophy The ZETA6xxx was not designed originally for EMC compliance. Therefore, it will require specific measures to be taken during installation.

More information

1. Mount the echo and tremolo control switches under the keyboard shelf, in a position convenient for the organist.

1. Mount the echo and tremolo control switches under the keyboard shelf, in a position convenient for the organist. CONSOLE CONNECTOR KIT 8101 INSTALLATION INSTRUCTIONS FOR USE WITH: HAMMOND Organ Models A-100, D-100, RT2, RT3 LESLIE Speaker Models 122, 122RV KIT CONTENT Console Connector Assembly 047357 Echo Control

More information

USER MANUAL MODEL 2017P MODEL 2017P60. RS-232 to 20mA and. RS-232 to 60mA Current Loop Converters

USER MANUAL MODEL 2017P MODEL 2017P60. RS-232 to 20mA and. RS-232 to 60mA Current Loop Converters USER MANUAL MODEL 2017P RS-232 to 20mA and MODEL 2017P60 RS-232 to 60mA Current Loop Converters 07M2017P-E Doc# 073051UE Revised 5/7/96 SALES OFFICE (301) 975-1000 TECHNICAL SUPPORT (301) 975-1007 1.0

More information

MICHIGAN DEPARTMENT OF TRANSPORTATION

MICHIGAN DEPARTMENT OF TRANSPORTATION MICHIGAN DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION FOR GROUNDING, BONDING, LIGHTNING PROTECTION AND SURGE PROTECTION FOR INTELLIGENT TRANSPORTATION SYSTEM EQUIPMENT ITS:CLC 1 of 5 APPR:LWB:DBP:07-31-13

More information

MICHIGAN DEPARTMENT OF TRANSPORTATION

MICHIGAN DEPARTMENT OF TRANSPORTATION MICHIGAN DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION FOR GROUNDING, BONDING, LIGHTNING PROTECTION AND SURGE PROTECTION FOR INTELLIGENT TRANSPORTATION SYSTEM EQUIPMENT ITS:CLC 1 of 6 APPR:MDW:JVG:06-08-18

More information

SPECIAL SPECIFICATION 1606 ISDN Compressed Video Equipment

SPECIAL SPECIFICATION 1606 ISDN Compressed Video Equipment 1993 Specifications CSJ 0043-09-104, etc. SPECIAL SPECIFICATION 1606 ISDN Compressed Video Equipment 1. Description. This Item shall govern for the furnishing and installation of Integrated Services Digital

More information

This Datasheet for the IC697CHS790. Rack, 9 Slots, Rear Mount.

This Datasheet for the IC697CHS790. Rack, 9 Slots, Rear Mount. This Datasheet for the IC697CHS790 Rack, 9 Slots, Rear Mount. http://www.cimtecautomation.com/parts/p-14771-ic697chs790.aspx Provides the wiring diagrams and installation guidelines for this GE Series

More information

SPECIAL SPECIFICATION 1861 Premium Subrate Data Multiplexer and Distribution Panel

SPECIAL SPECIFICATION 1861 Premium Subrate Data Multiplexer and Distribution Panel 1993 Specifications CSJ s 0924-06-221, etc. & 0924-06-223 SPECIAL SPECIFICATION 1861 Premium Subrate Data Multiplexer and Distribution Panel 1. Description. This Item shall govern for the furnishing and

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS CONSOLE CONNECTOR KIT 7830 FOR USE WITH: LESLIE Speaker Model 130 Various single and double channel organs INSTALLATION INSTRUCTIONS KIT CONTENT Console Connector 137283 Switch Assembly, Cable Assembly,

More information

Meter Enclosure and Equipment Standards

Meter Enclosure and Equipment Standards Meter Enclosure and Equipment Standards (a) (b) General Requirements: CITY OF OCALA UTILITY SERVICES METER ENCLOSURE AND EQUIPMENT STANDARDS: (1) To avoid the costs associated with having to replace unacceptable

More information

SPECIAL SPECIFICATION 6230 Fiber Optic RS-232 Data Modem

SPECIAL SPECIFICATION 6230 Fiber Optic RS-232 Data Modem 2004 Specifications CSJ 0924-06-258 SPECIAL SPECIFICATION 6230 Fiber Optic RS-232 Data Modem 1. Description. This Item shall govern for the furnishing and installation of Fiber Optic RS- 232 Data Modem

More information

ELECTRO-MECH SCOREBOARD CO.

ELECTRO-MECH SCOREBOARD CO. ELECTRO-MECH SCOREBOARD CO. MODEL 2350 BASKETBALL SCOREBOARD OWNER S HANDBOOK Thank you for choosing an Electro-Mech Scoreboard for your athletic complex. We are confident that your new scoreboard will

More information

SPECIAL SPECIFICATION 6146 Fiber Optic RS-232 Data Modem

SPECIAL SPECIFICATION 6146 Fiber Optic RS-232 Data Modem 2004 Specifications CSJ s 0508-07-027, 0177-06-064, 0271-04-067, 0389-13-049 SPECIAL SPECIFICATION 6146 Fiber Optic RS-232 Data Modem 1. Description. Furnish and install Fiber Optic RS-232 Data Modem (FO-MODEM)

More information

1993 Specifications CSJ SPECIAL SPECIFICATION ITEM Cabinet

1993 Specifications CSJ SPECIAL SPECIFICATION ITEM Cabinet 1993 Specifications CSJ 2552-03-023 1.0 Description. SPECIAL SPECIFICATION ITEM 6387 Cabinet This Item shall govern for the furnishing and installation of Type 3, Type 5 and Type P cabinets as shown on

More information

Secured Series: Hub Plus Kit Single Door Controller Package Installation Manual

Secured Series: Hub Plus Kit Single Door Controller Package Installation Manual Secured Series: Hub Plus Kit Single Door Controller Package Installation Manual This package is designed to simplify the connections to our Secured Series Hub Plus Controller. This will translate into

More information

Model 160. Model 186. Model 247. Surge Protective Devices. Installation & Operation Manual. Model 160. Model 186. Model 247 (EDCO RM-CX06-16R)

Model 160. Model 186. Model 247. Surge Protective Devices. Installation & Operation Manual. Model 160. Model 186. Model 247 (EDCO RM-CX06-16R) Surge Protective Devices Installation & Operation Manual Model 160 (16-Channel Coaxial) Model 186 (16 or 48 Channel Hi Speed Data Line Protector) Model 247 (120VAC Active Tracking Filter) Model 160 (EDCO

More information

SPECIAL SPECIFICATION 6322 Digital Video Encoder/Decoder (Ethernet) System

SPECIAL SPECIFICATION 6322 Digital Video Encoder/Decoder (Ethernet) System 2004 Specifications CSJ 0902-48-433 SPECIAL SPECIFICATION 6322 Digital Video Encoder/Decoder (Ethernet) System 1. Description. Furnish and install Digital Video Encoder/Decoder (Ethernet) System (DVE/DES)

More information

SECTION TRANSIENT VOLTAGE SUPPRESSION FOR LOW-VOLTAGE ELECTRICAL POWER CIRCUITS

SECTION TRANSIENT VOLTAGE SUPPRESSION FOR LOW-VOLTAGE ELECTRICAL POWER CIRCUITS SECTION 264313 - TRANSIENT VOLTAGE SUPPRESSION FOR LOW-VOLTAGE ELECTRICAL POWER CIRCUITS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and

More information

ELECTRO-MECH SCOREBOARD CO.

ELECTRO-MECH SCOREBOARD CO. ELECTRO-MECH SCOREBOARD CO. MODEL 2570 BASKETBALL SCOREBOARD OWNER S HANDBOOK Thank you for choosing an Electro-Mech Scoreboard for your athletic complex. We are confident that your new scoreboard will

More information

ELECTRO-MECH SCOREBOARD CO.

ELECTRO-MECH SCOREBOARD CO. ELECTRO-MECH SCOREBOARD CO. MP-320 DELAY OF GAME TIMER SCOREBOARD OWNER S HANDBOOK Thank you for choosing an Electro-Mech Scoreboard for your athletic complex. We are confident that your new scoreboard

More information

7011-C, 7012-C, 7013-C, 7015-C, 7018-C, 7021, MTC-2 Mass Terminated Assembly Twisted pair (45) 96-pin female 96-pin female 2 6.

7011-C, 7012-C, 7013-C, 7015-C, 7018-C, 7021, MTC-2 Mass Terminated Assembly Twisted pair (45) 96-pin female 96-pin female 2 6. TERMINATIONS LENGTH MODEL DESCRIPTION TYPE FROM TO m ft USE WITH: 236-ILC-3 Safety Interlock Shielded twisted pair 3-pin round 3-pin round 3 10 236, 237, 238, 8007, 8008 237-ALG-2 Low Noise Input Triax

More information

SPECIAL SPECIFICATION 1672 ISDN Compressed Video Equipment

SPECIAL SPECIFICATION 1672 ISDN Compressed Video Equipment 1993 Specifications CSJ s 0912-34-101 & 0027-08-108, etc. SPECIAL SPECIFICATION 1672 ISDN Compressed Video Equipment 1. Description. Furnish and install Integrated Services Digital Network (ISDN) Compressed

More information

CONSOLE CONNECTOR KIT 9501 INSTALLATION INSTRUCTIONS

CONSOLE CONNECTOR KIT 9501 INSTALLATION INSTRUCTIONS CONSOLE CONNECTOR KIT 9501 INSTALLATION INSTRUCTIONS FOR USE WITH: HAMMOND Organ Models L-100, M-100 Series, M-l, M-2, M-3 LESLIE Speaker Models 760, 770, 825 KIT CONTENT Console Connector Assembly 043075

More information

3a. IEM Indoor Metal Clad Medium Voltage Switchgear 25KV a. Section INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std.

3a. IEM Indoor Metal Clad Medium Voltage Switchgear 25KV a. Section INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std. 3a. IEM Indoor Metal Clad Medium Voltage Switchgear 25KV 16346-1 3a. Section 16346 INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std. Relays) Part 1 General 1.1 CONDITIONS AND REQUIREMENTS: A. Refer to

More information

Installing Power Modules

Installing Power Modules This chapter contains the procedures for installing cards and modules into the chassis after the chassis has been installed into a rack. This chapter also describes how to connect cables to RSP, RP, alarm,

More information

This network (Figure 5) has a Panel-Version Facilitator, Operator Terminal, five controllers, and a repeater.

This network (Figure 5) has a Panel-Version Facilitator, Operator Terminal, five controllers, and a repeater. This network (Figure 5) has a Panel-Version Facilitator, Operator Terminal, five controllers, and a repeater. Facilitator Panel Operator Terminal RS- Panel = EOL In W = across and W = across and DX900

More information

MODEL 8000MP LEVEL SENSOR

MODEL 8000MP LEVEL SENSOR 1 MODEL 8000MP LEVEL SENSOR INSTRUCTIONS FOR INSTALLATION, OPERATION & MAINTENANCE VISIT OUR WEBSITE SIGMACONTROLS.COM 2 SERIES 8000MP LEVEL SENSOR 1. DESCRIPTION The Model 8000MP Submersible Level Sensor

More information

An ISO-9001 Certified Company

An ISO-9001 Certified Company USER MANUAL MODEL 1002 and 1002S Asynchronous 2-Wire / Coax Short Range Modem An ISO-9001 Certified Company Part #07M1002-C Doc. #050011UC Revised 4/28/98 SALES OFFICE (301) 975-1000 TECHNICAL SUPPORT

More information

Modular plugs, accessories and tooling

Modular plugs, accessories and tooling Modular plugs, accessories and tooling Introducing the new Cat 6A/6 modular plugs, slim-line boots and color clips CommScope modular plug portfolio CommScope offers a vast portfolio of Modular Plugs for

More information

TOWN OF MANCHESTER GENERAL SERVICES DEPARTMENT 494 MAIN STREET P.O. BOX 191 MANCHESTER, CONNECTICUT

TOWN OF MANCHESTER GENERAL SERVICES DEPARTMENT 494 MAIN STREET P.O. BOX 191 MANCHESTER, CONNECTICUT TOWN OF MANCHESTER GENERAL SERVICES DEPARTMENT 494 MAIN STREET P.O. BOX 191 MANCHESTER, CONNECTICUT 06045-0191 TRAFFIC SIGNAL INSTALLATIONS MIDDLE TURNPIKE EAST AT SUMMIT STREET MIDDLE TURNPIKE EAST AT

More information

RICHMOND SIGNAL SYSTEM - JAHNKE AND FOREST VIEW SCHOOL DRIVE SPECIAL PROVISIONS FOR THERMAL VEHICLE DETECTION

RICHMOND SIGNAL SYSTEM - JAHNKE AND FOREST VIEW SCHOOL DRIVE SPECIAL PROVISIONS FOR THERMAL VEHICLE DETECTION RICHMOND SIGNAL SYSTEM - JAHNKE AND FOREST VIEW SCHOOL DRIVE SPECIAL PROVISIONS FOR THERMAL VEHICLE DETECTION I. Description September 9, 2018 This work shall consist of furnishing and installing a Thermal

More information

ELECTRICAL CONNECTORS ALL PRODUCTS

ELECTRICAL CONNECTORS ALL PRODUCTS ELECTRICAL CONNECTORS ALL PRODUCTS RENEWAL PARTS Supersedes: NOTHING Form 50.20-RP1 (103) LD08685 TABLE OF CONTENTS PAGE Single Line Micropanel...3 Optiview Panels...4 VSD's and Solid State Starters...5

More information

Release Notes. Electrostatic Discharge and Grounding Guide for Cisco NCS 2000 Series. Prerequisites. Preparing Your Location

Release Notes. Electrostatic Discharge and Grounding Guide for Cisco NCS 2000 Series. Prerequisites. Preparing Your Location First Published: 2017-01-31 Text Part Number: Electrostatic Discharge and Grounding Guide for Cisco NCS 2000 Series Prerequisites This document uses illustrations to explain the workflow that we recommend

More information

EMC Installation Guide

EMC Installation Guide A P P E N D I X B EMC Installation Guide General Product Philosophy Meeting requirements for electromagnetic compatibility (EMC) compliance will require specific measures to be taken during installation

More information

Special Specification 6016 ITS Field Equipment Cabinet

Special Specification 6016 ITS Field Equipment Cabinet 2004 Specifications Special Specification 6016 ITS Field Equipment Cabinet 1. Description. Furnish, install, and test equipment cabinets. 2. Materials. Furnish new, corrosion resistant materials. Furnish,

More information

Site Preparation CHAPTER

Site Preparation CHAPTER CHAPTER 3 Site Preparation This chapter describes the steps to take and the considerations you should keep in mind prior to installing the modules in an open rack. It also contains information that applies

More information

The SilverNugget is a servo controller/driver for NEMA 17 & 23 frame microstep motors.

The SilverNugget is a servo controller/driver for NEMA 17 & 23 frame microstep motors. Date: 5 November 2008 www.quicksilvercontrols.com SilverNugget N2 M-Grade The SilverNugget is a servo controller/driver for NEMA 17 & 23 frame microstep motors. Property of Page 1 of 13 This document is

More information

ELECTRO-MECH SCOREBOARD CO.

ELECTRO-MECH SCOREBOARD CO. ELECTRO-MECH SCOREBOARD CO. MP-259/220, MP-259/220V, MP-259/220W, MP-269/220, MP-269/220V, MP-269/220W BASKETBALL SCOREBOARDS OWNER S HANDBOOK Thank you for choosing an Electro-Mech Scoreboard for your

More information

M12 Field Wireable Connectors. M12 CAT.6A Field Wireable Connectors. M12 Field Wireable Connectors for PROFINET

M12 Field Wireable Connectors. M12 CAT.6A Field Wireable Connectors. M12 Field Wireable Connectors for PROFINET M12 Connectors Application Advantage Shielded design ETHERLINE Ethernet Cable, Connectors & Tools M12 Field Wireable Connectors Male Female Temperature Range: Max. 85 C Nominal Voltage: Nominal Current:

More information

PHOENIX CONTACT Pin. SUBCON-PLUS M ARCNET, MULTI/MININET (B&R), SYSTEM 2003 (B&R), P-NET SUCONET K1, K2 (EATON/Moeller),

PHOENIX CONTACT Pin. SUBCON-PLUS M ARCNET, MULTI/MININET (B&R), SYSTEM 2003 (B&R), P-NET SUCONET K1, K2 (EATON/Moeller), Fast connector with screw terminal block connection for fieldbus systems Data sheet 00287_en_02 PHOENIX CONTACT 207-04-2 Description The SUBCON-PLUS/... D-SUB series is specifically designed for use in

More information

5.1. Motor Protection and Monitoring. Contents. Product Overview. Monitoring Relays. D64R Series Digital Ground Fault Relays...

5.1. Motor Protection and Monitoring. Contents. Product Overview. Monitoring Relays. D64R Series Digital Ground Fault Relays... .1 Ground Fault Relays and Monitors Contents Description Current.................. Phase................... Voltage.................. Ground Fault Relays and Monitors D64R Series Digital Ground Fault Relays....

More information

Han-Brid. Contents Han-Brid Features Han-Brid Data interfaces Han-Brid Overview Han-Brid Cu

Han-Brid. Contents Han-Brid Features Han-Brid Data interfaces Han-Brid Overview Han-Brid Cu Contents Page Features... 19.02 Data interfaces... 19.03 Overview... 19.04 Cu... 19.06 F.O.... 19.08 Quintax 3 A... 19.10 RJ45 C... 19.12 USB / FireWire... 19.14 Han 4 A SC... 19.16 Hoods/Housings... 19.18

More information

NI PXIe-1062Q Power Supply Shuttle

NI PXIe-1062Q Power Supply Shuttle USER GUIDE NI PXIe-1062Q Power Supply Shuttle The NI PXIe-1062Q power supply shuttle is a replacement part for the NI PXIe-1062Q chassis. Caution This power supply is not compatible with any other National

More information

Modular Connectors 75

Modular Connectors 75 75 Plug/Jack Compliant to Enhanced Category 5 standards Connector type Size Series Name Page plug connectors compliant to enhanced category 5 standards 8 TM21P 77 jack connectors for high-speed LAN transmission

More information

CONEC Industrial Ethernet Circular Sealed RJ45 Connector System consists of a RJ45 Plug Kit, a Receptacle Kit and a Protective Cover Assembly.

CONEC Industrial Ethernet Circular Sealed RJ45 Connector System consists of a RJ45 Plug Kit, a Receptacle Kit and a Protective Cover Assembly. Revised Sept-28-2009 Sealed Industrial Ethernet Circular IP67 Cat. 5e RJ45 Connector System Instructions CONEC Industrial Ethernet Circular Sealed RJ45 Connector System consists of a RJ45 Plug Kit, a Kit

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS www.altroniccontrols.com INSTALLATION INSTRUCTIONS EXACTA 21 MONITORING AND CONTROL SYSTEM CAUTION: The EXACTA 21 CONTROL SYSTEM is CSA CERTIFIED FOR use in Class I, GROUPS C & D, Division 2 hazardous

More information

Operating Bulletin. Model BB3-232 and BB3-I-232 USB Multi-Drop Box. The Fastest Flow Controller Company in the World!

Operating Bulletin. Model BB3-232 and BB3-I-232 USB Multi-Drop Box. The Fastest Flow Controller Company in the World! Operating Bulletin Model BB3-232 and BB3-I-232 USB Multi-Drop Box The Fastest Flow Controller Company in the World! 1 10/16/2017 Rev.1 DOC-BB3232MAN 2 Introduction Alicat BB3-232 Multi-Drop Box Operating

More information

Special Specification 6017 Communications Hub Building

Special Specification 6017 Communications Hub Building Special Specification Communications Hub Building 1. DESCRIPTION Furnish and install Communications Hub Buildings as shown on the plans, as detailed in this Special Specification and as directed by the

More information

Posi-Lok Plugs and Panels

Posi-Lok Plugs and Panels THE SAFEST ELECTRICAL SYSTEM FOR HIGH AMPERAGE CONNECTIONS, POSI-LOK IS PART OF THE CAM-LOK FAMILY OF CONNECTORS. THE GROUND ALWAYS MAKES FIRST AND BREAKS LAST ALL POSI-LOK SYSTEMS ARE UL LISTED AND CSA

More information

920 Remote Control (RC) Switches

920 Remote Control (RC) Switches 920 Remote Control (RC) Switches ASCO is the global leader in power switching and controls ASCO 920 PRODUCT SPECIFICATIONS SWITCH ONLY (PANELBOARD MOUNTING) 1,2,3 () DIMENSIONS, IN.(MM) WIDTH HEIGHT DEPTH

More information

VCM Systems Vehicle Control Module Systems

VCM Systems Vehicle Control Module Systems VCM Systems Vehicle Control Module Systems Technical Manual VCMS-SC (Standard Configuration) Switch Panel System The Model VCMS-SC Switch Panel System is a standard configuration of the VCMS product family

More information

Wiring Best Practices

Wiring Best Practices Form Number F-2825 Issue Date Jan 3, 2018 Revision Date Jun 5, 2018 Wiring Best Practices Selecting, planning, and routing wires. Waterous Company 125 Hardman Avenue South South Saint Paul, MN 55075 (651)

More information

Meridian 1 Fiber Remote Multi-IPE Interface Description, installation, and maintenance

Meridian 1 Fiber Remote Multi-IPE Interface Description, installation, and maintenance Meridian 1 Description, installation, and maintenance Document Number: 553-3001-022 Document Release: Standard 3.00 Date: April 2000 Year Publish FCC TM Copyright 1996-2000 Nortel Networks All Rights Reserved

More information

Copyright Black Box Corporation. All rights reserved.

Copyright Black Box Corporation. All rights reserved. Copyright 2000. Black Box Corporation. All rights reserved. 1000 Park Drive Lawrence, PA 15055-1018 724-746-5500 Fax 724-746-0746 JUNE 2000 SP141A SP501A SP508A SP515A-R2 SP523A-R2 SP604A SP350A-R2 SP502A

More information

Model 2460-KIT. Screw Terminal Connector Kit. Description / September 2014 *P * 1

Model 2460-KIT. Screw Terminal Connector Kit. Description / September 2014 *P * 1 Keithley Instruments 28775 Aurora Road Cleveland, Ohio 44139 1-800-935-5595 http://www.keithley.com Model 2460-KIT Screw Terminal Connector Kit Description The Model 2460-KIT Screw Terminal Connector Kit

More information

Elastimold Molded Vacuum Recloser - MVR

Elastimold Molded Vacuum Recloser - MVR Subject: Elastimold Recloser Technical Specification Date: 4/24/12 File: MVR-RS-0412 Page: 1 of 6 1.0 SCOPE Elastimold Molded Vacuum Recloser - MVR 1.1 This specification covers electrical and mechanical

More information

USER MANUAL. MODEL 1225 ParaLink TM Parallel Short Range Modem. SALES OFFICE (301) TECHNICAL SUPPORT (301)

USER MANUAL. MODEL 1225 ParaLink TM Parallel Short Range Modem. SALES OFFICE (301) TECHNICAL SUPPORT (301) USER MANUAL MODEL 1225 ParaLink TM Parallel Short Range Modem C E R T I F I E D An ISO-9001 Certified Company Part #07M1225-B Doc. #104011UB Revised 9/12/97 SALES OFFICE (301) 975-1000 TECHNICAL SUPPORT

More information

STATE OF NEW JERSEY DEPARTMENT OF TRANSPORTATION TRENTON, NEW JERSEY SPECIFICATIONS FOR EIGHT PHASE TRAFFIC SIGNAL CONTROLLER ASSEMBLY

STATE OF NEW JERSEY DEPARTMENT OF TRANSPORTATION TRENTON, NEW JERSEY SPECIFICATIONS FOR EIGHT PHASE TRAFFIC SIGNAL CONTROLLER ASSEMBLY STATE OF NEW JERSEY DEPARTMENT OF TRANSPORTATION TRENTON, NEW JERSEY 08625 SPECIFICATIONS FOR EIGHT PHASE TRAFFIC SIGNAL CONTROLLER ASSEMBLY N. J. Specification No. Effective Date: July 1, 2001 New Jersey

More information

Model HM-535 Power Supply Installation and Service Instructions

Model HM-535 Power Supply Installation and Service Instructions Model HM-535 Power Supply Installation and Service Instructions 430-535 0104 2004 Heritage MedCall, Inc SENTRY INSTALLATION & SERVICE INSTRUCTIONS POWER SUPPLY UNIT Model HM-535 IMPORTANT SAFETY INSTRUCTIONS

More information

IST ULTRASTAB Power Supply for high precision transducers

IST ULTRASTAB Power Supply for high precision transducers IST ULTRASTAB Power Supply for high precision transducers High performance 6-channel power supply for multi-channel laboratory measurement applications. Features Current output or ±0 V voltage output (see

More information

Liebert AccuVar (ACV Series) Surge Protective Device (SPD) (With Noise Filtering) GUIDE SPECIFICATIONS for a Parallel Surge Suppression System

Liebert AccuVar (ACV Series) Surge Protective Device (SPD) (With Noise Filtering) GUIDE SPECIFICATIONS for a Parallel Surge Suppression System Liebert AccuVar (ACV Series) Surge Protective Device (SPD) (With Noise Filtering) GUIDE SPECIFICATIONS for a Parallel Surge Suppression System Part 1 General 1.01 Summary A. These specifications describe

More information

ME778C-RJ45 MAIN MODULE (FRONT CARD) MAIN MODULE. Line: RJ-45. Line: RJ-45 INTERFACE MODULE (REAR CARD) Serial: 10-Pin RJ.

ME778C-RJ45 MAIN MODULE (FRONT CARD) MAIN MODULE. Line: RJ-45. Line: RJ-45 INTERFACE MODULE (REAR CARD) Serial: 10-Pin RJ. ME778C-RJ45 Line: RJ-45 MAIN MODULE Mini Driver MP Card ME778C-RJ45 Power Line: RJ-45 Unit A -TD -RD -CD -TD Serial: 10-Pin RJ INTERFACE MODULE (REAR CARD) Unit B -RD -CD Serial: 10-Pin RJ LO Z A HI Z

More information

SPECIAL SPECIFICATION 6027 Lane Control Signal Equipment

SPECIAL SPECIFICATION 6027 Lane Control Signal Equipment 2004 Specifications SPECIAL SPECIFICATION 6027 Lane Control Signal Equipment 1. Description. Furnish and install Lane Control Signal (LCS) equipment. 2. Material. Provide new, corrosion resistant materials

More information

NOTE: Read the instructions completely through before beginning actual installation.

NOTE: Read the instructions completely through before beginning actual installation. CONSOLE CONNECTOR KIT 7850 INSTALLATION INSTRUCTIONS FOR USE WITH: Various Two-channel Organs LESLIE Speaker Models 705, 705C, 720 KIT CONTENT Console Connector 138488 Switch Assembly, Cable Assembly,

More information

Quick Start. This document describes how to install the Juniper Networks PTX5000 Packet Transport

Quick Start. This document describes how to install the Juniper Networks PTX5000 Packet Transport PTX5000 Packet Transport Router Quick Start September 2017 Part Number: 530-066788 Revision 01 This document describes how to install the Juniper Networks PTX5000 Packet Transport Router. Contents Quick

More information

ASCO 920 Remote Control (RC) Switches

ASCO 920 Remote Control (RC) Switches Maximum reliability and excellent value ASCO 920 Remote Control (RC) Switches ASCO 920 Remote Control Switch in Type Enclosure The ASCO 920 is designed as a feeder disconnect switch for load capacities

More information

SPOS (Station Point of Sale) 200. SFTP (Station Fare Transaction Processor) 35. CQD (Card Query Device) 35. HCR (Handheld Card Reader) Cradles 120

SPOS (Station Point of Sale) 200. SFTP (Station Fare Transaction Processor) 35. CQD (Card Query Device) 35. HCR (Handheld Card Reader) Cradles 120 DESIGN GUIDELINES PRESTO INSTALLATION & CONNECTIVITY PAGE 1 of 4 ELECTRICAL CONNECTIVITY AND WIRING Communications Conduits Conduits designated for Presto equipment data wiring shall be clearly identified

More information

USER MANUAL. MODEL 1018 High Speed Short Range Modem w/ Extra Controls SALES OFFICE (301) TECHNICAL SUPPORT (301)

USER MANUAL. MODEL 1018 High Speed Short Range Modem w/ Extra Controls SALES OFFICE (301) TECHNICAL SUPPORT (301) USER MANUAL MODEL 1018 High Speed Short Range Modem w/ Extra Controls Part# 07M1018-B Doc# 013021UB Revised 11/3/95 SALES OFFICE (301) 975-1000 TECHNICAL SUPPORT (301) 975-1007 1.0 WARRANTY INFORMATION

More information

ELECTRO-MECH SCOREBOARD CO.

ELECTRO-MECH SCOREBOARD CO. ELECTRO-MECH SCOREBOARD CO. MODEL 8850 HOCKEY SCOREBOARD OWNER S HANDBOOK Thank you for choosing an Electro-Mech Scoreboard for your athletic complex. We are confident that your new scoreboard will give

More information

Basketball Shot Clock Set LX2180 Manual

Basketball Shot Clock Set LX2180 Manual Basketball Shot Clock Set LX2180 Manual 72 Industrial Boulevard Wrightsville, GA 31096 Phone: (800) 445-7843 Fax: (800) 864-0212 www.electro-mech.com LX2180 Revision 5 February 8, 2013 Table of Contents

More information

Allen-Bradley PLCs. 100 Programmable Controller Processor Unit -Catalog Nos LPI01, -LP102, -LP103, -LP104 SLC TM. The Unit

Allen-Bradley PLCs. 100 Programmable Controller Processor Unit -Catalog Nos LPI01, -LP102, -LP103, -LP104 SLC TM. The Unit PRODUCT DATA SLC TM 100 Programmable Controller Processor Unit -Catalog Nos. 1745-LPI01, -LP102, -LP103, -LP104 The SLC 100 programmab/e Contro"er The SLC 100 Programmable Controller is easy to program,

More information

2U Congestion Alert Rack Insert for UK

2U Congestion Alert Rack Insert for UK 2U Congestion Alert Rack Insert for UK 2U Congestion Alert Rack Insert for UK The 2U congestion alert rack insert comes fully assembled, wired and ready to be installed in a rack. The rack provides communications,

More information

USP-070-B08 USP-104-B10, USP-104-M10 USP-156-B10

USP-070-B08 USP-104-B10, USP-104-M10 USP-156-B10 UniStream HMI Panel Installation Guide USP-070-B10, USP-070-B08 USP-104-B10, USP-104-M10 USP-156-B10 Unitronics UniStream platform comprises control devices that provide robust, flexible solutions for

More information

SLC Expansion Units Catalog Nos EI01, -El02,-El03, -El04, - IUS,-El06, -E107

SLC Expansion Units Catalog Nos EI01, -El02,-El03, -El04, - IUS,-El06, -E107 PRODUCT DA TA I YY J SLC 700 110 Expansion Units Catalog Nos. 1745-EI01, -El02,-El03, -El04, - IUS,-El06, -E107 e nit SLC 100 expansion units can be used with either the SLC 100 processor unit or SLC 150

More information

CO-485USB USB to RS-485 CONVERTER TECHNICAL REFERENCE

CO-485USB USB to RS-485 CONVERTER TECHNICAL REFERENCE TABLE OF CONTENTS CO-485USB USB to CONVERTER TECHNICAL REFERENCE Specifications, Description and Technical Support... page 1 Connection Diagram... page 2 Set-Up & Testing... page 3 & 4 Power Supply Shunts...

More information

Installing the Cisco 2524 and Cisco 2525 Routers

Installing the Cisco 2524 and Cisco 2525 Routers CHAPTER 3 Installing the Cisco 2524 and Cisco 2525 Routers This chapter guides you through the installation of the Cisco 2524 and Cisco 2525 routers and includes the following sections: Required Tools

More information

DATA CONNECT ENTERPRISE

DATA CONNECT ENTERPRISE DATA CONNECT ENTERPRISE User s Manual IG202T and IGV23 Modem Document Number 520-01005-001 Rev. A DATA CONNECT Contents Contents... iii Figures... iv Chapter 1 Introduction... 5 Features...6 Applications...7

More information

Research Concepts RC2500 Antenna Interface Unit (AIU) Board Set

Research Concepts RC2500 Antenna Interface Unit (AIU) Board Set Research Concepts RC2500 Antenna Interface Unit (AIU) Board Set A board set has been developed that can be incorporated into an AIU for an RC2500 antenna controller. This board set is the basis of RC2500

More information

Application Techniques CENTERLINE 2100 Motor Control Centers

Application Techniques CENTERLINE 2100 Motor Control Centers POWER SYSTEM CONSIDERATIONS FOR PRODUCT SELECTION Application Techniques CENTERLINE 2100 Motor Control Centers Power System Considerations for Product Selection i Power System Considerations for Product

More information

1. Carefully unpack the um260 s shipping carton and check the contents for damage.

1. Carefully unpack the um260 s shipping carton and check the contents for damage. um260 Installation Manual um260 Installation Chapter 4 um260 MICRO MONITOR INSTALLATION This section of the um260 Micro Monitor Installation Manual describes the requirements and procedures for installing

More information

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment FAST SHIPPING AND DELIVERY TENS OF THOUSANDS OF IN-STOCK ITEMS EQUIPMENT DEMOS HUNDREDS OF MANUFACTURERS SUPPORTED

More information