Table of Contents Chapter 3 Installing the Switch

Size: px
Start display at page:

Download "Table of Contents Chapter 3 Installing the Switch"

Transcription

1 Table of Contents Table of Contents Installation Flow Confirming Installation Preparation Mounting the Switch in a Rack Preparations Installing the Cable Management Bracket and Rack-Mounting Ears Mounting the Switch Verifying the Installation Installing the Switch on a Workbench Preparations Procedure Connecting the PGND Wire In a common grounding environment In other Grounding Environments Installing a PSU Installation Preparation Installation Procedure Connecting Power Cable(s) Installing a Board Installation Preparations Installation Procedure Installing PoE Power Supply Installation Procedure Installing the PoE Power Entry Module Connecting PoE Power Cables Connecting Interface Cables Cable Routing Recommendations Connecting Console Cable Connecting the AUX Cable Connecting Network Cables Connecting Fiber Verifying the Installation i

2 The S9500 series are designed for indoor applications. Warning: Do not touch any exposed wires, terminals or any parts labelled with a high-voltage hazard warning to avoid bodily injury. 3.1 Installation Flow Start Confirm installation preparation Confirm installation position Mount the switch in a rack Install the switch on a workbench Connect the PGND wire Install a PSU Install boards Install PoE power supply (optional) Connect interface cables Verify the installation Finish Figure 3-1 Installation flow 3.2 Confirming Installation Preparation Make sure that you have read Chapter 2 Preparing for the Installation carefully. 3-1

3 All requirements mentioned in Chapter 2 Preparing for the Installation have been met. 3.3 Mounting the Switch in a Rack Preparations Before installation, make sure that: The cabinet is grounded and stable. The layout inside the cabinet for switch installation has been well done and there is no obstacle inside or around the cabinet. The switch is ready for installation and has been carried to a place near the cabinet Installing the Cable Management Bracket and Rack-Mounting Ears For your convenience, a cable management bracket is shipped with the S9500 series. Take the following steps to install the cable management bracket. 1) Facing the LPU slots of the switch, insert the shipped cable management bracket into the left rack-mounting ear on which there is a recessed hole for installing the cable management bracket, and fix it with screws. (One cable management bracket for the S9505/S9508/S9508V and two for the S9512). 2) Install the rack-mounting ears onto the both sides of the switch, as shown in Figure 3-2. Figure 3-2 Install the cable management bracket and rack-mounting ears 3-2

4 3.3.3 Mounting the Switch Note: Make sure that supports have been installed in corresponding positions and the supports can bear the switch weight. 1) Two people are required to lift the switch. Put the switch on the supports and slide it into the cabinet until the rack-mounting ears touch against the front square-holed columns. 2) Fix the rack mounting ears onto the square-holed columns with screws. Figure 3-3 Install the switch into a standard 19-inch rack Verifying the Installation After installing the switch into the rack, check the items listed in Table 3-1. Table 3-1 Checklist for switch installation Item The cable management bracket is well fixed on the left rack-mounting ear. Result Yes No Remarks 3-3

5 Item The rack-mounting ears are well fixed on the switch. The installation position is right. The rack-mounting ears are well fixed on the rack Result Yes No Remarks 3.4 Installing the Switch on a Workbench When no 19-inch cabinet is available, you can place the switch on a clean and stable workbench Preparations Make sure that the workbench is sturdy enough to bear the weight of the switch and cables. Make sure that the workbench is flat and well grounded Procedure Lift the switch onto the workbench with another person. Caution: Reserve at least 15.2 cm (6.0 in.) of clearance around the switch for heat dissipation. 3.5 Connecting the PGND Wire Caution: For the safety of operators and equipment, the switch must be well grounded. The resistance reading between switch chassis and the ground must be less than 1 ohm. 3-4

6 3.5.1 In a common grounding environment Follow these steps to connect the PGND wire in a common grounding environment: 1) Remove the screw from the grounding hole in the switch chassis. 2) Wear the connector of the PGND wire accompanied with the switch on the grounding screw. 3) Insert the grounding screw into the grounding hole and screw it down. 4) Connect the other end of the PGND wire to the ground bar of the switch, as shown in Figure 3-4. Figure 3-4 Connect the PGND wire Note: Generally, the cabinets installed in equipment rooms are equipped with ground bar. In this case, you can connect the PGND wire of the switch to the ground bar for it In other Grounding Environments The following are some methods for grounding the switch in different grounding environments. 3-5

7 Note: Rather than specifying the switch model or showing the actual location of the switch power input or grounding screw, the following figures are primarily intended for illustrating the switch grounding, either via grounding screw or power input, in specific grounding environments. If a ground bar is available, attach one end of the yellow-green PGND wire of the switch to a grounding bolt of the ground bar and fasten the captive screws. Caution: Note that neither the fire hydrant nor lightning rod of a building is suitable for grounding the switch. The PGND wire of the switch should be connected to the grounding device in the equipment room. (For the S9500 series, the grounding screw is on the rear panel. Connect it as illustrated in Figure 3-5). (1) (2) (3) (4) (1) Rear panel of the switch (2) Grounding screw (3) PGND wire (4) Ground bar of the equipment room Figure 3-5 Ground the switch when a ground bar is available 3-6

8 If there is no ground bar but earth nearby and the grounding body is allowed to be buried, you can simply hammer an angle iron or steel pipe no shorter than 0.5 m into the earth. Caution: The yellow-green PGND wire should be welded with the angle iron (steel pipe) and the joint should be processed against eroding. (For the S9500 series, the grounding screw is on the rear panel. Connect it as illustrated in Figure 3-5). (1) (2) (3) (4) (5) (1) Rear panel of the switch (2) Grounding screw (3) PGND wire (4) Ground (5) Angle steel (steel pipe) Figure 3-6 Ground the switch when allowed to bury grounding body nearby If both ground bar and the conditions for burying the grounding body are not available, an AC-powered Ethernet switch can be grounded using the PE wire of the AC power supply. 3-7

9 Caution: Make sure that the PE wire of the AC power supply has been well grounded at the side of the power distribution room or AC power supply transformer. (1) (2) (3) (4) (5) (1) Front panel of the switch (2) AC power input (3) 3-core AC power cord (4) Transformer (5) Protection earth (PE) wire Figure 3-7 Ground the switch through the AC PE wire If no ground bar or condition for burying the grounding body is available, a DC-powered Ethernet switch can be grounded through the PGND strip of the power distribution frame (PDF). Caution: Make sure the RTN wire is well connected to the ground at the DC output of the PDF. 3-8

10 (1) (6) (2) (5) (3) (4) (12) (11) (7) (8) (10) (9) (1) Front panel of the (2) DC power input (3) NEG terminal switch (4) RTN terminal (5) PDF (6) -48V strip (7) RTN strip (8) PGND strip (9) Earth ground (10) PGND wire (11) Grounding screw (12) Rear panel of the switch Figure 3-8 Ground the switch through the PGND strip of the PDF 3.6 Installing a PSU Installation Preparation Wear an ESD-preventive wrist strap and verify the ESD-preventive wrist strap is properly grounded. If there is a filler panel in the position where you will install a PSU, remove the filler panel. Caution: When you move a PSU, hold its bottom with one hand. Do not move it by just holding its handle. Otherwise, the PSU may be damaged Installation Procedure I. Removing a PSU other than NEPS3500-A The following procedure applies to all NEPS PSUs except NEPS3500-A. 3-9

11 1) Clutch the air filter cover by the upper and lower edges with your index finger and the thumb, and gently remove the air filter cover from a PSU. Note: You can pull out the PSU handle only after removing the air filter cover. 2) Slide the PSU smoothly along the guide rails, until it snaps into the backplane. Figure 3-9 Install an AC PSU 3) Fasten the captive screws on both sides of the PSU with a Philips screwdriver and install the removed air filter cover onto the PSU. 4) Check that the power switch on the PSU is in the OFF position. II. Installing NEPS3500-A NEPS3500-A contains two sub-psu slots. You can configure one or two 1800 W sub-psus. Follow these steps to install NEPS3500-A: 1) Install a NEPS3500-A enclosure into the switch. 2) Install one to two 1800 W sub-psus into the NEPS3500-A enclosure. 3-10

12 Table 3-2 Procedure of installing NEPS3500-A Step Install the NEPS3500-A enclosure into the switch Install 1800 W sub-psu(s) to the NEPS3500-A enclosure Sub-step 1) Hold the handle on the enclosure with one hand and the bottom with the other hand, and gently slide the enclosure along the guide rails into the switch. 2) Fasten the captive screws on both sides of the enclosure with a Philips screwdriver. 3) Check that the power switch on the enclosure is in the OFF position. 1) Pull down the handle on the sub-psu (refer to the leftmost graph in Figure 3-10). 2) Slide the sub-psu smoothly along the guide rails, until it snaps into the backplane. 3) Push the handle upward so that the sub-psu moves further inside about 1 cm (0.39 in) until the handle locks the sub-psu in place, as shown in the rightmost graph in Figure Figure 3-10 Install a 1800 W sub-psu Connecting Power Cable(s) I. Connecting the AC power cord Caution: For lightning protection, the AC power supply should be led through an external lightning device into the switch. Make sure the power switch on the PSU is in the OFF position before connecting the AC power cord. Take the following steps to connect the AC power cord to NEPS1200-A, or NEPS2000-A: 1) Turn the clamp at the left of the PSU front panel rightwards. 2) Insert the plug at one end of the AC power cord into the socket of the PSU. 3) Turn the clamp leftwards until it grips the plug. 3-11

13 4) Insert the other end of the power cord into an external power socket. (1) Connector-retention clamp (2) Input LED (3) Output LED (4) Fail LED (5) Power switch (6) PSU handle (7) AC power cord Figure 3-11 NEPS1200-A appearance (1) Connector-retention clamp (2) Input LED (3) Output LED (4) Fail LED (5) Power switch (6) PSU handle (7) AC power cord Figure 3-12 NEPS2000-A appearance Take the following steps to connect the AC power cord to NEPS3500-A: 1) Insert the plug at one end of the AC power cord into the socket on the PSU. 3-12

14 2) Install the clamp to the socket of the PSU until it grips the plug. 3) Insert the other end of the power cord into an external power socket. (1) (1) (6) (2) (3) (4) (5) (1) Power switch (2) Input LED (3) Output LED (4) Fail LED (5) PSU handle (6) AC power cord Figure 3-13 NEPS3500-A appearance II. Connecting DC Power Cables The DC power cables are connected to the terminal block, and are fixed with screws. A plastic cover plate is installed in front of the terminal block for the sake of connection reliability. Caution: Completely power off the switch before connecting the DC power cord. Before removing or installing the DC power cables, you need to remove the plastic cover plate. Install it after installing/removing the DC power cables. Take the following steps to connect the DC power cables: 1) Remove the plastic cover plate and loosen the fixing screws on the terminal block of the DC PSU with a Philips screwdriver. 2) Connect one end of the cable with 48V OT terminals (blue) to the NEG( ) terminal on the PSU and fasten the corresponding fixing screw. 3-13

15 Connect the other end to the NEG ( ) terminal of the source power supply. 3) Connect one end of the cable with GND OT terminals (black) to the RTN (+) terminal on the PSU and fasten the corresponding fixing screw. Connect the other end to the RTN (+) terminal of the power source. 4) Connect one end of the cable with PGND OT terminals (yellow-green) to the PGND terminal on the PSU and fasten the corresponding fixing screw. Connect the other end to the ground bar of the switch. 5) Install the plastic cover plate. (1) Terminal block (2) Input LED (3) Output LED (4) Fail LED (5) Power switch (6) PSU handle Figure 3-14 NEPS1200-D appearance 3-14

16 (1) Terminal block (2) Input LED (3) Output LED (4) Fail LED (5) Power switch Figure 3-15 NEPS2000-D appearance Note: NEPS3500-D is similar to NEPS2000-D in appearance, as shown in Figure The DC PSUs shown in the above figures are not equipped with plastic cover plates. 3.7 Installing a Board The installation procedures of SRPUs, LPUs, and service boards are almost the same. The following section describes the installation procedure of LPUs Installation Preparations Wear the ESD-preventive wrist strap, making sure that it is properly grounded. Loosen the mounting screws on the blank filler panel where the SRPU is to be installed using a Phillips screwdriver and remove the blank filler panel. Prepare the LPU to be installed. 3-15

17 Note: Put the removed blank filler panel away for future use. The LPUs of the S9500 series are hot-swappable Installation Procedure Follow the procedure below to install an LPU: 1) Turn the ejector levers on the LPU outward simultaneously with both hands, insert the LPU straight into the chassis along the guide rails until it stops sliding (that is, the positioning pins on the ejector levers touch the positioning holes on the chassis). 2) Turn the ejector levers towards the front panel to drive the positioning pins into the positioning holes. Figure 3-16 Install an LPU 3) Fix the LPU by fastening the mounting screws on the LPU with a Phillips screwdriver. 3.8 Installing PoE Power Supply The S9505/S9508/S9512 uses PSE4500-A as an external PoE power supply, which is connected to the switch through the PoE power entry module at the front bottom of the switch to provide power for connected powered devices (PDs). The following introduces the installation of PoE power supply on the S

18 3.8.1 Installation Procedure Wear the ESD-preventive wrist strap, making sure that it is properly grounded. Remove blank filler panels in the power supply area if applicable Installing the PoE Power Entry Module The PoE power entry module is hot-swappable. Follow the steps below to install the PoE power entry module: 1) Unpack the PoE power entry module, which is shown in Figure Figure 3-17 PoE power entry module 2) Keep the PoE power entry module in the correct letter direction. (Do not turn it upside down. Otherwise, you will not be able to fully insert it into the chassis due to mis-plug prevention design of the module, nor can you fasten the chassis fixing screw.) Hold the bottom with one hand and the front panel with the other, and then slide it smoothly along the guide rails into the slot, until it snaps into the chassis. Make sure the plug of the PoE power entry module is fully connected with the socket inside the chassis. See Figure

19 Figure 3-18 Install the PoE power entry module 3) Fasten the screws on the top of the PoE entry module with a Philips screwdriver Connecting PoE Power Cables Note: This section only focuses on the cable connection between the external PoE power supply and the S9500 series switch. For the installation of the external PoE power supply, see the manual accompanying the power supply. I. Grounding the PoE chassis Follow these steps to ground the PoE chassis: 1) Connect the wiring terminal (with one M6 hole) of the 6 AWG cable to the grounding screw on the rear panel of the switch, as shown in Figure ) Connect the other end of the cable to the grounding bar or other grounding terminals. 3-18

20 (1) (1) Chassis grounding screw Figure 3-19 Ground the PoE chassis II. Connecting PoE power cables 1) Loosen the mounting screws on the PoE power entry module with a Phillips screwdriver. 2) Connect one 48V OT terminal of the blue DC power cable to the NEG ( ) terminal of the PoE power entry module and fasten the mounting screw; connect the other end to the NEG ( ) terminal of the external PoE power supply. 3) Connect the PGND OT terminal of the black DC power cable to the RTN (+) terminal of the PoE power entry module and fasten the mounting screw; connect the other end to the RTN (+) terminal of the external PoE power supply. Caution: Observe the polarity signs on devices and connect the cables correctly. Choose right cables based on the load. 3-19

21 (1) NEG( ) terminal of DC output (2) RTN(+) terminal of DC output (3) AC input switch (4) AC input socket Figure 3-20 Input/output of external PoE power supply 3.9 Connecting Interface Cables Cable Routing Recommendations Interface cables and power cables should be routed separately. You can bind long cables with cable ties. For specific binding requirements, refer to Appendix A Cable Binding. I. Workbench-mounted switch All interface cables are routed to the left side (the cable management bracket) of the chassis, and power cables are routed to the front of the chassis. II. Rack-Mounted switch The interface cables are bound on the cable management bracket on the left side of the chassis and are routed up or down to pass through the chassis top or the raised floor, depending on the available equipment room condition (that is, signal cables are routed into the chassis either from the cabling racks on the chassis top or from the cabling trough under the floor). All digital signal cable connectors should be put at the bottom of the cabinet. Do not put them outside the cabinet. Power cables run along the left-front of the chassis and out of the chassis either from the top or the raised floor, depending on the equipment room conditions (PDF, lightning protection box, and terminal block, etc.) in the equipment room. 3-20

22 Caution: Do not bind cables at the air exhaust vents of the switch to prevent premature cable aging. Fix cables as near the device as possible. The cables between the fixing point and device interfaces must be bound loosely. To identify cables, you can stick labels on them. For more information, refer to Appendix B Engineering Labels for Cables Connecting Console Cable I. Introduction Console cable is an 8-core shielded cable. At one end of the cable is a crimped RJ-45 connector that is to be plugged into the console port of the switch. At the other end of the cable is a DB-9 (female) connector. You can plug it into the 9-pin (male) serial port on the console terminal. The following figure illustrates the console cable. Figure 3-21 Console cable Table 3-3 Console cable pinouts RJ-45 Signal DB-9 Signal 1 RTS 8 CTS 2 DTR 6 DSR 3 TXD 2 RXD 4 CD 5 SG 5 GND 5 SG 6 RXD 3 TXD 7 DSR 4 DTR 3-21

23 RJ-45 Signal DB-9 Signal 8 CTS 7 RTS II. Connecting the console cable Take the following steps to connect the console cable, when configuring the switch on the terminal. 1) Plug the DB-9 female connector of the console cable into the serial port of the PC/terminal where the switch is to be configured. 2) Connect the RJ-45 connector of the console cable to the console port of the switch. Figure 3-22 Connect the console cable Note: The PC serial port is not hot-swappable, so you are not allowed to insert or remove the console cable into or from the PC serial port. When connecting the console cable, first connect the DB9 end to the PC serial port and then the RJ45 end to the console port of the switch. And removing the console cable is just in inverse order. When removing the console cable, first remove the RJ-45 end and then the DB9 end. 3-22

24 3.9.3 Connecting the AUX Cable You need an AUX cable when configuring the S9500 series with the remote modem dial-up approach. I. Introduction The AUX cable is an 8-core shielded cable. At one end of the cable is an RS-232-compliant RJ-45 connector that can be plugged into the AUX port of the switch. At the other end is DB-9 (male) connector. You can plug it into the DB-9 (female) port of the modem. The AUX cable is the same as the console cable. For details, refer to Figure 3-21 and Table 3-3. II. Connecting AUX cable 1) Plug the RJ-45 connector of the AUX cable into the AUX port of the switch. 2) Plug the DB-9 (male) connector at the other end into the serial port of the modem Connecting Network Cables I. Introduction to RJ-45 connector The 10/100/1000Base-T ports of the S9500 series support MDI/MDI-X auto-sensing. They are connected to category-5 shielded cables or above that are equipped with RJ-45 connectors. Figure 3-23 RJ-45 connector II. Connection procedure 1) Plug one end of the network cable into the Ethernet RJ-45 port to be connected on the switch. 2) Plug the other end of the cable into the RJ-45 port of the peer device Connecting Fiber I. Installing fiber management tray (optional) 3-23

25 Note: The installation method described below is based on an N68 cabinet. The installation procedure is only for your reference if you use a non-n68 cabinet. A fiber management tray (FMT) is installed in a cabinet for winding redundant fibers between the S9500 and other devices. 1) Preparations The installation prerequisites are as follows: The cabinet is fixed well. The device has been installed completely. The installation involves the following materials: FMT M5 10 self-tapping screws (two screws for one FMT) 2) Installation Procedure To install the fiber management tray, proceed as shown in Figure Align the fiber management tray and the installation holes on the column of the cabinet. Use a Phillips screwdriver to fix each fiber management tray with two M5 10 self-tapping screws. Figure 3-24 Install FMTs 3-24

26 II. Introduction to fiber connector Note: When selecting a fiber network facility, make sure that the type of the connector and the fiber match the adopted optical port. Before connecting the fiber, make sure that the receive-end optical power does not exceed the optical module s upper threshold of receiving optical power. Excessive receiving optical power is very likely to burn the optical module. All the megabit and gigabit optical modules available on the S9500 series are SFP modules and all interfaces on SFP modules adopt LC connectors. Fiber connectors are indispensable passive components in an optical fiber communication system. They allow the removable connection between optical channels, which makes the optical system debugging and maintenance more convenient and the transit dispatching of the system more flexible. Among various fiber connectors, only the LC connector is introduced here. Figure 3-25 LC connector III. Precautions Be sure to install the dust cover if the optical port is not connected to a fiber connector. Some invisible rays may be emitted from the optical port if the optical port is not connected to a fiber connector or the dust cover is removed. Therefore, never stare at the optical port directly. Fiber connectors must be protected under safe and reliable outer packing, and be fitted with dust caps. Fiber connectors must be installed with dust caps when they are not in use. Take care not to scratch their end face. Replace the dust cap if it loose or polluted. Before connecting a fiber, use dustfree paper and absolute alcohol to clean the end face of the fiber connector. You can brush the end face 3-25

27 only in one direction. You also need to brush the end face of the other fiber connector. Never bend or curve a fiber when connecting it. After a fiber is installed well, the bend radius must be not less than 40 mm (the minimum dynamic bend radius is 20 D, and the minimum static bend radius is 10 D. D indicates the outer diameter of fiber jackets). If the fiber has to pass through a metallic board hole, the hole must have a sleek and fully filleted surface (the filleting radius must be not less than 2 mm). When passing through a metallic board hole or bending along the acute side of mechanical parts, the fiber must wear jackets or cushions. Insert and remove a plug with care. Never exert a fierce force to the fiber or plug; otherwise the plug may be damaged or the fiber may be broken. Never pull, press or extrude the fiber fiercely. For the allowed maximum tensile load and crush load, refer to Table 3-4. Table 3-4 Allowed maximum tensile force and crush load Period of force Tensile load (N) Crush load (N/100 mm) Short period Long term IV. Connection procedure 1) Connect one end of the fiber to the SFP module of the S9500 series. 2) Connect the other end of the fiber to the peer device. 3-26

28 3.10 Verifying the Installation Warning: Make sure that you have turned off the power before checking the installation in case of bodily injury and device damage. After installing the switch, verify the installation against the following list. For the successful installation, all items must be normal. Table 3-5 Installation checklist Item Console cable PGND wire Power cables SRPUs LPUs/service boards Fan tray(s) PSUs Normal Abnormal (Description) 3-27

Installation Manual. Table of Contents

Installation Manual. Table of Contents Table of Contents Table of Contents... 4-1 4.1 Confirming the Installation Preparations... 4-1 4.2 Installation Flowchart... 4-1 4.3 Mounting the Switch to the Designated Position... 4-2 4.3.1 Mounting

More information

Table of Contents Chapter 4 Switch Installation

Table of Contents Chapter 4 Switch Installation Table of Contents Table of Contents... 4-1 4.1 Confirming Installation reparation... 4-1 4.2 Installation Flow... 4-1 4.3 Mounting the Switch in User-Supplied Cabinet... 4-2 4.3.1 Cabinet Configuration

More information

H3C S12500 Routing Switch Series

H3C S12500 Routing Switch Series H3C S12500 Routing Switch Series Quick Installation Guide Hangzhou H3C Technologies Co., Ltd. http://www.h3c.com Document version: APW201-20131030 Copyright 2013, Hangzhou H3C Technologies Co., Ltd. and

More information

Junos WebApp Secure 5.0 Hardware Guide

Junos WebApp Secure 5.0 Hardware Guide Junos WebApp Secure 5.0 Hardware Guide Junos WebApp Secure 5.0 Hardware Guide This document contains a specification for the MWS1000 hardware appliance, as well as instructions for installation into a

More information

Quick Start. This document describes how to install the Juniper Networks PTX5000 Packet Transport

Quick Start. This document describes how to install the Juniper Networks PTX5000 Packet Transport PTX5000 Packet Transport Router Quick Start September 2017 Part Number: 530-066788 Revision 01 This document describes how to install the Juniper Networks PTX5000 Packet Transport Router. Contents Quick

More information

Replacing the Power Supply

Replacing the Power Supply APPENDIX B This appendix includes information on how to replace the power supply for the Cisco AS550XM universal gateway and contains the following sections: Safety Recommendations, page B-1 Required Tools

More information

Installing Power Modules

Installing Power Modules This chapter contains the procedures for installing cards and modules into the chassis after the chassis has been installed into a rack. This chapter also describes how to connect cables to RSP, RP, alarm,

More information

HP 5820X & 5800 Switch Series

HP 5820X & 5800 Switch Series HP 5820X & 5800 Switch Series Installation Guide Abstract This document guides you through installation of HP products, including installing the device, connecting to the network, hardware management,

More information

Quick Installation Guide 4 Slot Chassis-Based Switch

Quick Installation Guide 4 Slot Chassis-Based Switch Quick Installation Guide 4 Slot Chassis-Based Switch This document will guide you through the basic installation process for your new D-Link chassisbased Switch DGS-6604 Documentation also available on

More information

Installing the Cisco ADE 2130 and 2140 Series Appliance Hardware Options

Installing the Cisco ADE 2130 and 2140 Series Appliance Hardware Options CHAPTER 4 Installing the Cisco ADE 2130 and 2140 Series Appliance Hardware Options This chapter provides instructions for installing, replacing, and removing various hardware options in your Cisco ADE

More information

Gateway Profile 4 service guide

Gateway Profile 4 service guide Gateway Profile 4 service guide Customizing Troubleshooting Contents Replacing Components in Your Gateway Profile 4.................. 1 About this guide.....................................................

More information

HP 5500 HI Switch Series

HP 5500 HI Switch Series HP 5500 HI Switch Series Installation Guide Part number: 5998-2373 Document version: 6W102-20130601 Legal and notice information Copyright 2011-2013 Hewlett-Packard Development Company, L.P. No part of

More information

Dell Networking C9010 Getting Started Guide

Dell Networking C9010 Getting Started Guide Dell Networking C9010 Getting Started Guide Regulatory Model: C9010 Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your computer. CAUTION:

More information

Installing the Cisco MDS 9020 Fabric Switch

Installing the Cisco MDS 9020 Fabric Switch CHAPTER 2 This chapter describes how to install the Cisco MDS 9020 Fabric Switch and its components, and it includes the following information: Pre-Installation, page 2-2 Installing the Switch in a Cabinet

More information

Serial ATA Hot Swap Drive Cage Upgrade Kit for: Intel Server Chassis SC5200 Intel Server Chassis SC5250-E

Serial ATA Hot Swap Drive Cage Upgrade Kit for: Intel Server Chassis SC5200 Intel Server Chassis SC5250-E Serial ATA Hot Swap Drive Cage Upgrade Kit for: Intel Server Chassis SC5200 Intel Server Chassis SC5250-E A Guide for Technically Qualified Assemblers of Intel Identified Subassemblies/Products Order Number:

More information

To connect the AC adapter:

To connect the AC adapter: Replacing the AC Adapter Replacing the AC Adapter 3 Plug the power cord into a wall outlet. The power indicator turns on. To connect the AC adapter: Connect the power cord to the AC adapter. Power indicator

More information

Cisco ASR 1004 Router Overview and Installation

Cisco ASR 1004 Router Overview and Installation Cisco ASR 004 Router Overview and Installation This chapter describes the Cisco ASR 004 Router and the procedures for installing the Cisco ASR 004 Router on an equipment shelf or tabletop or in equipment

More information

H3C S7503-S7506-S7506R Ethernet Switches Power Distribution Box Installation Guide

H3C S7503-S7506-S7506R Ethernet Switches Power Distribution Box Installation Guide H3C S7503-S7506-S7506R Ethernet Switches Power Distribution Box Installation Guide Hangzhou H3C Technologies Co., Ltd. http://www.h3c.com Manual Version: T2-08050R-20070521-C-1.01 Copyright 2006-2007,

More information

H3C S5600 Series Ethernet Switches

H3C S5600 Series Ethernet Switches Installation Manual Hangzhou H3C Technologies Co., Ltd. http://www.h3c.com Manual Version: T2-08045W-20071218-C-1.04 Copyright 2006-2007, Hangzhou H3C Technologies Co., Ltd. and its licensors All Rights

More information

Installing the ASA 5550

Installing the ASA 5550 CHAPTER 3 Installing the ASA 5550 Caution Read the safety warnings in the Regulatory Compliance and Safety Information for the Cisco ASA 5500 Series and follow proper safety procedures when performing

More information

Installing and Upgrading Memory and Virtual Private Network Modules

Installing and Upgrading Memory and Virtual Private Network Modules APPENDIX C Installing and Upgrading Memory and Virtual Private Network Modules This chapter tells how to install or upgrade memory and how to install a Virtual Private Network (VPN) module in your Cisco

More information

Installing the Cisco SFS 3504 Server Switch

Installing the Cisco SFS 3504 Server Switch CHAPTER 3 This chapter describes how to mount your Cisco SFS 3504 Server Switch on a rack, boot the Cisco SFS 3504 Server Switch, and configure basic services. For advanced configuration information, see

More information

Cisco CRS 3-Phase AC Power Distribution Unit Installation Guide 2. Cisco CRS 3-Phase AC Power Distribution Unit 2

Cisco CRS 3-Phase AC Power Distribution Unit Installation Guide 2. Cisco CRS 3-Phase AC Power Distribution Unit 2 Cisco CRS 3-Phase AC Power Distribution Unit Installation Guide Cisco CRS 3-Phase AC Power Distribution Unit Installation Guide 2 Cisco CRS 3-Phase AC Power Distribution Unit 2 Revised: November 18, 2016,

More information

Installing and Removing SDRAM and DRAM

Installing and Removing SDRAM and DRAM CHAPTER 4 This chapter explains how to remove and replace the main memory modules on the network processing engine or network services engine. For the location of the memory module you are replacing, find

More information

HPE 5820X & 5800 Switch Series

HPE 5820X & 5800 Switch Series HPE 5820X & 5800 Switch Series Installation Guide Part number: 5998-6792u Document version: 6W107-20170825 Copyright 2015, 2017 Hewlett Packard Enterprise Development LP The information contained herein

More information

Installation and Maintenance

Installation and Maintenance CHAPTER 4 Installation and Maintenance Revised: April 19, 2010, Introduction This chapter explains how to install a SCE 1000 platform in a rack or in a general tabletop or workbench installation. Additionally,

More information

Installing a Network Module

Installing a Network Module 3 CHAPTER This chapter describes how to install and connect a network module. Overview, page 3-1 in the Switch, page 3-4 SFP and SFP+ Modules, page 3-7 Finding the Network Module Serial Number, page 3-9

More information

HP 5500 EI & 5500 SI Switch Series

HP 5500 EI & 5500 SI Switch Series HP 5500 EI & 5500 SI Switch Series Installation Guide Part number: 5998-1710c Document version: 6W102-20160927 Copyright 2016 Hewlett Packard Enterprise Development LP The information contained herein

More information

Maintaining E-Series Routers

Maintaining E-Series Routers Maintaining E-Series Routers 9 This chapter lists the tools, items, and steps needed for installing and uninstalling E-series components. Other maintenance procedures must be performed by an authorized

More information

Installing the MWAM CHAPTER

Installing the MWAM CHAPTER CHAPTER This chapter provides information about installing the MWAM in a Catalyst 600/Cisco 7600 chassis and includes the following topics: Safety Recommendations, page -2, page - Verifying the Installation,

More information

QFX10008 Switch Quick Start Guide

QFX10008 Switch Quick Start Guide QFX10008 Switch Quick Start Guide January 2014 Part Number: 530-068237 Revision 01 This document describes how to install the Juniper Networks QFX10008 Switch Chassis. Contents Quick Start Description...............................................

More information

H3C S5560-EI Switch Series

H3C S5560-EI Switch Series H3C S5560-EI Switch Series Installation Guide New H3C Technologies Co., Ltd. http://www.h3c.com Document version: 6W104-20180704 Copyright 2015-2018, New H3C Technologies Co., Ltd. and its licensors All

More information

Installation Job Aid for VSP 4450GTX-HT- PWR+

Installation Job Aid for VSP 4450GTX-HT- PWR+ Installation Job Aid for VSP 4450GTX-HT- PWR+ Notices Release 6.1.0.0 NN46251-305 Issue 02.01 November 2017 Notice paragraphs alert you about issues that require your attention. The following paragraphs

More information

MX Voice Gateway Series. Installation Manual

MX Voice Gateway Series. Installation Manual MX Voice Gateway Series Installation Manual Revision Record Revision version 1.0 (2009-05-07 Author:ZNH) The first revision. Shanghai New Rock Technologies, Inc. Page 2/23 Contents 1 Installation Preparation...

More information

Removing and Replacing Chassis Components

Removing and Replacing Chassis Components This chapter provides instructions on how to remove and replace components from the Cisco NCS 4016 chassis., on page 1 Removing a Line Card This section describes how to remove a line card from the Cisco

More information

Installing the Cisco AS5400XM Universal Gateway

Installing the Cisco AS5400XM Universal Gateway CHAPTER 3 Installing the Cisco AS5400XM Universal Gateway This chapter guides you through the installation of the Cisco AS5400XM universal gateway and includes the following sections: Setting Up the Chassis,

More information

Installing a Network Module

Installing a Network Module Network Modules Overview, page 1 in the Switch, page 2 Removing a Network Module, page 10 SFP and SFP+ Modules, page 11 Finding the Network Module Serial Number, page 13 Network Modules Overview The Cisco

More information

Installing the Cisco 2524 and Cisco 2525 Routers

Installing the Cisco 2524 and Cisco 2525 Routers CHAPTER 3 Installing the Cisco 2524 and Cisco 2525 Routers This chapter guides you through the installation of the Cisco 2524 and Cisco 2525 routers and includes the following sections: Required Tools

More information

HP 5500 HI Switch Series

HP 5500 HI Switch Series HP 5500 HI Switch Series Installation Guide Part number: 5998-2373b Document version: 6W104-20160516 Legal and notice information Copyright 2011-2016 Hewlett-Packard Development Company, L.P. No part of

More information

Installation Job Aid for VSP 4850GTS

Installation Job Aid for VSP 4850GTS Installation Job Aid for VSP 4850GTS Notices Release 6.1.0.0 NN46251-308 Issue 02.01 November 2017 Notice paragraphs alert you about issues that require your attention. The following paragraphs describe

More information

Installation Job Aid for Ethernet Routing Switch 5900 Series

Installation Job Aid for Ethernet Routing Switch 5900 Series Installation Job Aid for Ethernet Routing Switch 5900 Series Notices NN47211-301 Issue 05.01 November 2017 Notice paragraphs alert you about issues that require your attention. The following paragraphs

More information

Installation Job Aid for Avaya Virtual Services Platform 8400

Installation Job Aid for Avaya Virtual Services Platform 8400 Installation Job Aid for Avaya Virtual Services Platform 8400 Support Release 4.2 NN47227-305 Issue 01.06 June 2015 Go to the Avaya Support website at http://support.avaya.com for the most up-to-date documentation,

More information

Installing a Network Module

Installing a Network Module Network Module Overview, page in the Switch, page 7 Removing a Network Module, page 3 SFP and SFP+ Modules, page 4 Finding the Network Module Serial Number, page 6 Network Module Overview Network Module

More information

Preparing to Install the VG248

Preparing to Install the VG248 CHAPTER 2 To ensure normal system operation, plan your site configuration and prepare your site before installation. Before installing the VG248, review these sections: Preparing the Installation Site,

More information

KIEN2204S Industrial Ethernet Switch Hardware Installation Manual

KIEN2204S Industrial Ethernet Switch Hardware Installation Manual KIEN2204S Industrial Ethernet Switch Hardware Installation Manual Kyland Technology Co., Ltd. Publication Date: Mar. 2013 Version: V1.0 FAX: +86-10-88796678 Website: http://www.kyland.com E-mail: support@kyland.com

More information

Installation Note for the Cisco ME 3800X and ME 3600X Switch Power Supply and Fan Modules

Installation Note for the Cisco ME 3800X and ME 3600X Switch Power Supply and Fan Modules Installation Note for the Cisco ME 3800X and ME 3600X Switch Power Supply and Fan Modules This document provides the installation and removal instructions for the AC and DC input power supply and fan modules

More information

HP A10500 Switch Series. Installation Guide. Abstract

HP A10500 Switch Series. Installation Guide. Abstract HP A10500 Switch Series Installation Guide Abstract This document guides you through installation of HP A Series products, including installing the device, connecting to the network, hardware management,

More information

HP A5120 EI & A5120 SI Switch Series. Installation Guide. Abstract

HP A5120 EI & A5120 SI Switch Series. Installation Guide. Abstract HP A5120 EI & A5120 SI Switch Series Installation Guide Abstract This document guides you through installation of HP A Series products, including installing the device, connecting to the network, hardware

More information

HPE FlexNetwork 5130 HI Switch Series

HPE FlexNetwork 5130 HI Switch Series HPE FlexNetwork 5130 HI Switch Series Installation Guide Part number: 5998-8420e Document version: 6W102-20180315 Copyright 2016, 2018 Hewlett Packard Enterprise Development LP The information contained

More information

S4112-ON Series. Setup Guide

S4112-ON Series. Setup Guide S4112-ON Series Setup Guide Notes, cautions, and warnings NOTE: A NOTE indicates important information that helps you make better use of your product. CAUTION: A CAUTION indicates either potential damage

More information

H3C S5120-HI Switch Series

H3C S5120-HI Switch Series H3C S5120-HI Switch Series Installation Guide Hangzhou H3C Technologies Co., Ltd. http://www.h3c.com Document version: 6W102-20130630 Copyright 2011-2013, Hangzhou H3C Technologies Co., Ltd. and its licensors

More information

HP 5830 Switch Series. Installation Guide. Abstract

HP 5830 Switch Series. Installation Guide. Abstract HP 5830 Switch Series Installation Guide Abstract This document guides you through installation of HP A Series products, including installing the device, connecting to the network, hardware management,

More information

Managing Individual Components

Managing Individual Components CHAPTER 3 This chapter describes how to install the Field Replaceable Units (FRUs) in the Cisco SFS 7008P system. About the Field Replaceable Units The following Field Replaceable Units (FRUs) are a part

More information

Power Supply and Fan Module Installation

Power Supply and Fan Module Installation 3 CHAPTER This chapter describes how to remove and install a new or replacement power supply or fan module in a Catalyst 3750-E or Catalyst 3560-E switch. See these sections: Installation Overview, page

More information

Dell Networking S4810 Open Networking (ON) Getting Started Guide

Dell Networking S4810 Open Networking (ON) Getting Started Guide Dell Networking S4810 Open Networking (ON) Getting Started Guide Regulatory Model: S4810 Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your

More information

Installation Manual. Mounting Instructions Mechanical Mounting. Luminato. Teleste Corporation

Installation Manual. Mounting Instructions Mechanical Mounting. Luminato. Teleste Corporation Luminato Installation Manual Teleste Corporation Mounting Instructions Mechanical Mounting Luminato Mechanical Installation, agile_59300316, rev0044 Introduction 1 Contents Introduction 4 General... 4

More information

Switch Installation. Preparing for Installation. Safety Warnings

Switch Installation. Preparing for Installation. Safety Warnings For initial switch setup, assigning the switch IP address, and powering on information, see the switch getting started guide on Cisco.com. This chapter contains these topics: Preparing for Installation,

More information

H3C S7508E-X Switch. Installation Guide. Hangzhou H3C Technologies Co., Ltd. Document version: 6PW

H3C S7508E-X Switch. Installation Guide. Hangzhou H3C Technologies Co., Ltd.   Document version: 6PW H3C S7508E-X Switch Installation Guide Hangzhou H3C Technologies Co., Ltd. http://www.h3c.com Document version: 6PW102-20110826 Copyright 2011, Hangzhou H3C Technologies Co., Ltd. and its licensors All

More information

Conventions. Preface. Technical Support & Helpline. Install Guide TNDS-9000P 9-Port Gigabit PoE Switch Series

Conventions. Preface. Technical Support & Helpline. Install Guide TNDS-9000P 9-Port Gigabit PoE Switch Series Install Guide TNDS-9000P 9-Port Gigabit PoE Switch Series 2015 TitanNetworx LTD. All rights reserved. TitanNetworx is a registered trademark legally held by TitanNetworx LTD. Other brand and product names

More information

Rack Installation Instructions

Rack Installation Instructions Rack Installation Instructions Review the documentation that comes with your rack cabinet for safety and cabling information. When installing your server in a rack cabinet, consider the following: v Two

More information

Cisco ONS CL Shelf Assembly Hardware

Cisco ONS CL Shelf Assembly Hardware CHAPTER 1 This chapter provides a description of Cisco ONS 15310-CL shelf hardware. Instructions for installing equipment are provided in the Cisco ONS 15310-CL and Cisco ONS 15310-MA Procedure Guide.

More information

Installation Guide V290 (Color) This guide provides basic information for Unitronics LCD color touchscreen models V C30B and V T40B.

Installation Guide V290 (Color) This guide provides basic information for Unitronics LCD color touchscreen models V C30B and V T40B. Vision OPLC Installation Guide V290 (Color) This guide provides basic information for Unitronics LCD color touchscreen models V290-19-C30B and V290-19-T40B. General Description Vision OPLCs are programmable

More information

Removing and Replacing Parts

Removing and Replacing Parts Removing and Replacing Parts Preparing to Work Inside the Computer Recommended Tools Screw Identification System Components Hard Drive Fixed Optical Drive Media Bay Devices Memory Modules Mini PCI Card

More information

120Ra-1 Pentium III Processor Installation Insert

120Ra-1 Pentium III Processor Installation Insert 120Ra-1 Pentium III Processor Installation Insert PN: 455-01614-000 Proprietary Notice and Liability Disclaimer The information disclosed in this document, including all designs and related materials,

More information

HP CX4 & XFP Interface Cards User Guide

HP CX4 & XFP Interface Cards User Guide HP CX4 & XFP Interface Cards User Guide Introduction to CX4&XFP interface cards Overview Table 1 CX4&XFP interface cards brief introduction Model Product Code Description LSPM1CX2P JD360B Each LSPM1CX2P

More information

Installation Job Aid for Ethernet Routing Switch 3600 Series

Installation Job Aid for Ethernet Routing Switch 3600 Series Installation Job Aid for Ethernet Routing Switch 3600 Series Notices NN47213-303 Issue 03.01 November 2017 Notice paragraphs alert you about issues that require your attention. Following are descriptions

More information

TRC-190 User s Manual

TRC-190 User s Manual User s Manual Edition 3.2, May 2017 www.moxa.com/product 2017 Moxa Inc. All rights reserved. User s Manual The software described in this manual is furnished under a license agreement and may be used only

More information

Dell Getting Started Guide for the S6100 ON System March 2016

Dell Getting Started Guide for the S6100 ON System March 2016 Dell Getting Started Guide for the S6100 ON System March 2016 Regulatory Model: S6100 Regulatory Type: S6100 Notes, cautions, and warnings NOTE: A NOTE indicates important information that helps you make

More information

Codian MSE 8000 Media Services Engine

Codian MSE 8000 Media Services Engine Codian MSE 8000 Media Services Engine Getting started Codian MSE 8000 Media Services Engine Getting started Copyright Codian 2008. All rights reserved. This Getting Started Guide may not be copied, photocopied,

More information

Module Connectors and Cable Specifications

Module Connectors and Cable Specifications Module Connectors, page 1 Cables and Adapters, page 2 Cleaning the Fiber-Optic Connectors, page 6 Module Connectors RJ-45 Connector The RJ-45 connector is used to connect a Category 3, Category 5, Category

More information

HP UPS R/T3000 G2. Overview. Precautions. Kit contents. Installation Instructions

HP UPS R/T3000 G2. Overview. Precautions. Kit contents. Installation Instructions HP UPS R/T3000 G2 Installation Instructions Overview The HP UPS R/T3000 G2 features a 2U rack-mount with convertible tower design and offers power protection for loads up to a maximum of 3300 VA/3000 W

More information

HP UPS R/T3000 ERM. Overview. Precautions. Installation Instructions

HP UPS R/T3000 ERM. Overview. Precautions. Installation Instructions HP UPS R/T3000 ERM Installation Instructions Overview The ERM consists of two battery packs in a 2U chassis. The ERM connects directly to a UPS R/T3000 or to another ERM. Up to two ERM units can be connected.

More information

Installing the Cisco Unified Videoconferencing 3545 MCU

Installing the Cisco Unified Videoconferencing 3545 MCU CHAPTER 2 Installing the Cisco Unified Videoconferencing 3545 MCU The Cisco Unified Videoconferencing 3545 MCU works together with a Cisco Unified Videoconferencing 3545 EMP Enhanced Media Processor (EMP)

More information

Maintaining the ERX System

Maintaining the ERX System 7 This chapter describes the procedures that you must perform to maintain the ERX system and its components. Other maintenance procedures must be performed by an authorized Juniper Networks technician.

More information

Maintaining the Cisco Internet Router

Maintaining the Cisco Internet Router CHAPTER 5 Maintaining the Cisco 12404 Internet Router Overview This chapter contains safety at the field replaceable unit (FRU) level, removal and replacement instructions for FRUs and procedures to troubleshoot

More information

TRC-190 User s Manual

TRC-190 User s Manual First Edition, November 2008 www.moxa.com/product 2008 Moxa Inc. All rights reserved. Reproduction without permission is prohibited. The software described in this manual is furnished under a license agreement

More information

Preparing to Install the Cisco AS5350XM Universal Gateway

Preparing to Install the Cisco AS5350XM Universal Gateway CHAPTER 2 Preparing to Install the Cisco AS5350XM Universal Gateway This chapter describes the tasks you must perform before you begin to install the Cisco AS5350XM universal gateway and includes the following

More information

Unpacking an Epica Distribution Matrix

Unpacking an Epica Distribution Matrix an Epica Distribution Matrix An Epica Distribution Matrix is shipped with one enclosure in each palleted box. Each box contains one of each of the following items (invoices are sent separately): Power

More information

HPE FlexNetwork 5510 HI Switch Series

HPE FlexNetwork 5510 HI Switch Series HPE FlexNetwork 5510 HI Switch Series Installation Guide Part number: 5200-0020b Document version: 6W101-20160930 Copyright 2016 Hewlett Packard Enterprise Development LP The information contained herein

More information

Dell Networking S4100-ON Series. Set-Up Guide

Dell Networking S4100-ON Series. Set-Up Guide Dell Networking S4100-ON Series Set-Up Guide Notes, cautions, and warnings NOTE: A NOTE indicates important information that helps you make better use of your product. CAUTION: A CAUTION indicates either

More information

ExtremeSwitching 210 and 220 Series Switches: Hardware Installation Guide

ExtremeSwitching 210 and 220 Series Switches: Hardware Installation Guide ExtremeSwitching 210 and 220 Series Switches: Hardware Installation Guide 122039-00 Published May 2017 Copyright 2017 Extreme Networks, Inc. All rights reserved. Legal Notice Extreme Networks, Inc. reserves

More information

Instructions for SVC-KIT-0020

Instructions for SVC-KIT-0020 Kaleidescape, Inc. July 22, 2010 Instructions for SVC-KIT-0020 Title Time to complete 1U Server Power Supply Replacement 1 hour Procedure to complete Locate Parts and Tools Service Kit Parts Power supply

More information

Switch Installation. Preparing. Safety Warnings CHAPTER

Switch Installation. Preparing. Safety Warnings CHAPTER 2 CHAPTER Read these topics and perform the procedures in this order: Preparing, page 2-1 Planning a Switch Stack, page 2-5 Installing the Switch, page 2-10 Connecting the FlexStack Cables, page 2-17 Installing

More information

Maintaining the ERX System

Maintaining the ERX System Maintaining the ERX System 7 This chapter describes the procedures that you must complete to maintain the ERX system and its components. Other maintenance procedures must be performed by an authorized

More information

Installation Guide V290 (Color) This guide provides basic information for Unitronics LCD color touchscreen models V C30B and V T40B.

Installation Guide V290 (Color) This guide provides basic information for Unitronics LCD color touchscreen models V C30B and V T40B. Vision OPLC Installation Guide V290 (Color) This guide provides basic information for Unitronics LCD color touchscreen models V290-19-C30B and V290-19-T40B. General Description Vision OPLCs are programmable

More information

H3C SecPath M9000-S NSQM2MPUD0 main processing unit

H3C SecPath M9000-S NSQM2MPUD0 main processing unit H3C SecPath M9000-S NSQM2MPUD0 main processing unit 1 Identifier The module identifier NSQM2MPUD0 is at the upper right corner of the front panel. 2 The NSQM2MPUD0 MPU has a console port, a USB port, a

More information

Chassis Overview. About the Cisco NCS 4016 Chassis. This chapter provides an overview of the Cisco NCS 4016 chassis and components.

Chassis Overview. About the Cisco NCS 4016 Chassis. This chapter provides an overview of the Cisco NCS 4016 chassis and components. This chapter provides an overview of the Cisco NCS 4016 chassis and components. About the Cisco NCS 4016 Chassis, page 1 Chassis Components, page 6 Chassis Cable Management, page 11 Safety Guidelines,

More information

Installing the Cisco VG224 Voice Gateway

Installing the Cisco VG224 Voice Gateway CHAPTER 3 This chapter contains the procedures for installing your Cisco VG224 voice gateway and consists of the following sections: Safety Recommendations, page 3-2 Site Log, page 3-3 Keeping Track Checklist,

More information

HD Flex Zero RU Cassette Holder and Bracket

HD Flex Zero RU Cassette Holder and Bracket HD Flex Zero RU Cassette Holder and Bracket Part Numbers: FLEX-0RUBR**, FLEX0RUCH** Panduit Corp. 2016 INSTALLATION INSTRUCTIONS The Zero RU Cassette Holder and Bracket are designed to mount on the side

More information

PIX 515/515E. PIX 515/515E Product Overview CHAPTER

PIX 515/515E. PIX 515/515E Product Overview CHAPTER CHAPTER 4 PIX 515/515E This chapter describes how to install the PIX 515/515E, and includes the following sections: PIX 515/515E Product Overview Installing a PIX 515/515E PIX 515/515E Feature Licenses

More information

Power Supply Installation

Power Supply Installation Power Supply Module Overview, on page Installation Guidelines, on page 4 Installing or Replacing an AC Power Supply, on page 6 Installing a DC Power Supply, on page 7 Finding the Power Supply Module Serial

More information

Installing the Cisco ASR 901 Mobile Wireless Router as a Satellite Shelf

Installing the Cisco ASR 901 Mobile Wireless Router as a Satellite Shelf Installing the Cisco ASR 901 Mobile Wireless Router as a Satellite Shelf The chapter describes how to install the Cisco ASR 901 router as a satellite shelf, and how to connect it to networks and external

More information

Replacing the Gateway M275 Keyboard

Replacing the Gateway M275 Keyboard Replacing the Gateway M275 Keyboard This package includes a replacement keyboard for your Gateway M275 notebook and these printed instructions. Tools you need You need a small Phillips screwdriver and

More information

Replacement Instructions

Replacement Instructions apple Xserve Memory Replacement Instructions Follow the instructions in this sheet carefully. Failure to follow these instructions could damage your equipment and void its warranty. Note: Online instructions

More information

Microsoft Azure StorSimple Appliance 8600 Hardware Installation Guide

Microsoft Azure StorSimple Appliance 8600 Hardware Installation Guide Microsoft Azure StorSimple Appliance 8600 Hardware Installation Guide Contents Unpack your device... Prerequisites... Unpacking your device... Rack-mount your device... Site preparation... Prerequisites...

More information

Keysight M8000 Series BER Test Solutions

Keysight M8000 Series BER Test Solutions Keysight M8000 Series BER Test Solutions J-BERT M8020A High-Performance BERT M8030A Multi-Channel BERT M8040A High-Performance BERT M8041A, M8051A, M8061A, M8062A, M8045A, M8046A & M8057A Tips for Preventing

More information

DLA. DMX512 Analyzer. DLA Users Manual SV2_00 B.lwp copyright ELM Video Technology, Inc.

DLA. DMX512 Analyzer. DLA Users Manual SV2_00 B.lwp copyright ELM Video Technology, Inc. DLA DMX512 Analyzer DLA DLA-HH 1 Table Of Contents IMPORTANT SAFEGUARDS... 2 DLA OVERVIEW... 3 CONNECTION... 3 OPERATION... 3 HARDWARE SETUP... 4 DLA-HH (PORTABLE) LAYOUT... 4 CHASSIS LAYOUT... 4 DLA MENU

More information

S5048F-ON. Set-up Guide

S5048F-ON. Set-up Guide S5048F-ON Set-up Guide Notes, cautions, and warnings NOTE: A NOTE indicates important information that helps you make better use of your product. CAUTION: A CAUTION indicates either potential damage to

More information

H3C S6520X-EI & S6520X-HI Switch Series

H3C S6520X-EI & S6520X-HI Switch Series H3C S6520X-EI & S6520X-HI Switch Series Installation Guide New H3C Technologies Co., Ltd. http://www.h3c.com Document version: 5W101-20180430 Copyright 2018, New H3C Technologies Co., Ltd. and its licensors

More information

Installing the Cisco XR Router

Installing the Cisco XR Router CHAPTER3 This chapter contains the procedures to install the router in a rack. The installation is presented in the following sections: Pre-Installation Considerations and Requirements, page 3-2 Installation

More information