VectorStar ME7838A4 Multiport Broadband/Banded Millimeter-Wave System

Size: px
Start display at page:

Download "VectorStar ME7838A4 Multiport Broadband/Banded Millimeter-Wave System"

Transcription

1 Quick Start Guide VectorStar ME7A4 Multiport Broadband/Banded Millimeter-Wave System High Performance Modular Broadband/Banded Millimeter-Wave Vector Network Analyzer (VNA) Multiport Measurement System ME7A4, 70 khz to 0 () GHz Anritsu Company 490 Jarvis Drive Morgan Hill, CA USA Part Number: Revision: A Published: March 0 Copyright 0 Anritsu Company

2 . ME7A4 Main Components High Performance Modular Broadband/Banded Millimeter-Wave Vector Network Analyzer (VNA) Measurement System, 70 khz to GHz This guide provides quick setup instructions for the ME7A4 Multiport Broadband/Banded mm-wave VNA System assembly. For additional safety and compliance information, and for more details about the assembly, configuration, setup, and initial testing of the equipment, refer to the VectorStar ME7A4 Series Multiport Broadband Vector Network Analyzers Installation Guide This and all other documentation that supports the ME7A4 is available on the VectorStar User Documentation Disc Calibration, Verification, and System Performance Verification documents are included on a separate disc included with each calibration/verification kit.. ME7A4 Main Components ME7A4 Broadband Systems The ME7A4 Multiport Broadband system consists of the following components: MS447A or MS447B VNA with Option 007 (Receiver Offset) and Option 0x (Modular Broadband Connection Capability) MN497C Multiport Test Set 7B Broadband Test Set 79C Broadband Test Set Four 74A Millimeter-Wave Modules Front and rear panel cables ME7A4 Banded Systems The ME7A4 Multiport Banded system consists of the following components: MS44xA/B VNA with Option 0x MN494C Multiport Test Set 7B Broadband Test Set 79C Broadband Test Set Four 744A-EE, 744A-EW, or four OML/VDI Millimeter-Wave Modules Front and rear panel cables Caution A MS44xA/B VNA unit is heavy. To avoid personal injury, it must be lifted and maneuvered by at least two people during installation. If mounting on a workbench surface, first position the 79C Broadband Test Set with access to its front and rear panels. Stack the remaining test sets on top of one another, then finally the VNA. If mounting into rack or console, make sure the Test Sets have been installed, and that the rack/console is carefully positioned on a flat and level surface. If equipped, make sure any casters are locked. Use two people to lift the VNA unit and two to guide it into its shelf rails. The test loops on the front and rear panels of the VNA are delicate. Be careful not to bump or bend the test loops. QSG- PN: Rev. A VectorStar ME7A4 QSG

3 . Rear Panel Connections Between System Components (MS44xA VNA). Rear Panel Connections Between System Components (MS44xA VNA) In this section, connect the cables between the VNA and the Test Sets as shown in Figure and Table MS44xA VNA MN49xC Test Set B Test Set 4 Ext Alc Out Ext Analog In IF Outputs a b a b External I/O Module Interface Cable Length WARNING No operator serviceable parts inside. Refer servicing to qualified personnel. CAUTION Do not operate with power cord ungrounded. ~ LINE INPUT 47- Hz -40 VAC 0 VA Max Fuse 0V A T CAUTION 79C Test Set Standard Extended For continued fire protection replace only with specified type and rated fuse. Figure ME7A4 Rear Panel Cable Connections (MS44xA VNA) VectorStar ME7A4 QSG PN: Rev. A QSG-

4 . Rear Panel Connections Between System Components (MS44xA VNA) Table. ME7A4 Multiport Rear Panel Cable Connections ( of ) Index Part Number Cable Description Connection From Connection To -0- BNC (male-male), 4 in -0- BNC (male-male), 4 in -0- BNC (male-male), 4 in 4-0- BNC (male-male), 4 in a ( cable bundle) -074 a ( cable bundle) DB- DB GPIB, m SMA male-male flexible: SMA male-male flexible: a SMA male-male -0 a SMA male-male - a SMA male-male 4-0 a SMA male-male - a SMA male-male -0 a SMA male-male 7 - a SMA male-male MS44xA port Ext Analog Out MS44xA port Ext ALC 7B port (To Test Set) EXT ANALOG OUT 7B port (To Test Set) EXT ALC IN 7B port TO TEST SET EXTERNAL I/O 7B ports (IF INPUTS) a b a b MS44xA ports (Inputs/Outputs) a IF b IF a IF b IF MS44xA port External I/O MS44xA port Dedicated GPIB MS44xA port b loop out MS44xA port b loop in MS44xA port P source loop out MS44xA port P source loop in MS44xA port b loop out MS44xA port b loop in MS44xA port P source loop out 7B port EXT ANALOG IN 7B port EXT ALC OUT 79C port EXT ANALOG IN 79C port EXT ALC OUT 79C port EXTERNAL I/O 79C ports (IF OUTPUTS) a b a b 7B ports (IF OUTPUTS) a IF b IF a IF b IF 7B port TO VNA EXTERNAL I/O MN49xC port IEEE 4. GPIB MN49xC port TO VNA b OUTPUT MN49xC port TO VNA b INPUT MN49xC port TO VNA Port Src OUTPUT MN49xC port TO VNA Port Src INPUT MN49xC port TO VNA b OUTPUT MN49xC port TO VNA b INPUT MN49xC port TO VNA Port Src OUTPUT QSG-4 PN: Rev. A VectorStar ME7A4 QSG

5 . Rear Panel Connections Between System Components (MS44xA VNA) Table. ME7A4 Multiport Rear Panel Cable Connections ( of ) Index Part Number Cable Description Connection From Connection To -0 a SMA male-male 9 MS44xA VNA 0 MN49xC Test Set 7B Test Set 79C Test Set MS44xA port P source loop in a. Tighten each cable in this group using an mm (/ in) torque end wrench set to 0.9 N m ( lbf in). MN49xC port TO VNA Port Src INPUT VectorStar ME7A4 QSG PN: Rev. A QSG-

6 . Rear Panel Connections Between Components (MS44xB VNA). Rear Panel Connections Between Components (MS44xB VNA) In this section, connect the cables between the VNA and the Test Sets as shown in Figure or Figure, and Table. Cable Connections (Systems with Option 0 Dual Source Architecture) Ext In ALC and Ext In ALC (With Option 0) 9 MS44xB VNA MN49xC Test Set Ext ALC (With Option 0) B Test Set Ext ALC (With Option 0) 4 Ext Alc Out Ext Analog In IF Outputs a b a b External I/O Module Interface Cable Length Standard Extended WARNING No operator serviceable parts inside. Refer servicing to qualified personnel. CAUTION Do not operate with power cord ungrounded. ~ LINE INPUT 47- Hz -40 VAC 0 VA Max Fuse 0V A T CAUTION For continued fire protection replace only with specified type and rated fuse. 79C Test Set Figure ME7A4 Multiport BB/mmW VNA System Rear Panel Cables (With Option 0) QSG- PN: Rev. A VectorStar ME7A4 QSG

7 Cable Connections (Systems without Option 0). Rear Panel Connections Between Components (MS44xB VNA) MS44xB VNA MN49xC Test Set B Test Set 4 Ext Alc Out Ext Analog In IF Outputs a b a b External I/O Module Interface Cable Length WARNING No operator serviceable parts inside. Refer servicing to qualified personnel. CAUTION Do not operate with power cord ungrounded. ~ LINE INPUT 47- Hz -40 VAC 0 VA Max Fuse 0V A T CAUTION 79C Test Set Standard Extended For continued fire protection replace only with specified type and rated fuse. Figure ME7A4 Multiport BB/mmW VNA System Rear Panel Cables (No Option 0) VectorStar ME7A4 QSG PN: Rev. A QSG-7

8 . Rear Panel Connections Between Components (MS44xB VNA) Table. ME7A4 Multiport Rear Panel Cable Connections (MS44xB) ( of ) Index Part Number Cable Description Connection From Connection To -0- BNC (male-male), 4 in -0- BNC (male-male), 4 in -0- BNC (male-male), 4 in -0- BNC (male-male), 4 in -0- BNC (male-male), 4 in 4-0- BNC (male-male), 4 in a ( cable bundle) -074 a ( cable bundle) DB- DB GPIB, m SMA male-male flexible: SMA male-male flexible: a SMA male-male -0 a SMA male-male - a SMA male-male MS44xB port Ext Analog Out Ext In ALC (No Option 0) (Figure ) Ext In ALC (With Option 0) (Figure ) Ext In ALC (With Option 0) (Figure ) 7B port (To Test Set) EXT ANALOG OUT 7B port (To Test Set) EXT ALC IN (Figure ) (Not used with Option 0) 7B port TO TEST SET EXTERNAL I/O 7B ports (IF INPUTS) a b a b MS44xB ports (Inputs/Outputs) a IF b IF a IF b IF MS44xB port External I/O MS44xB port Dedicated GPIB MS44xB port b loop out MS44xB port b loop in MS44xB port P source loop out 7B port EXT ANALOG IN 7B port EXT ALC OUT 79C port EXT ALC OUT 7B port EXT ALC OUT 79C port EXT ANALOG IN 79C port EXT ALC OUT 79C port EXTERNAL I/O 79C ports (IF OUTPUTS) a b a b 7B ports (IF OUTPUTS) a IF b IF a IF b IF 7B port TO VNA EXTERNAL I/O MN49xC port IEEE 4. GPIB MN49xC port TO VNA b OUTPUT MN49xC port TO VNA b INPUT MN49xC port TO VNA Port Src OUTPUT QSG- PN: Rev. A VectorStar ME7A4 QSG

9 . Rear Panel Connections Between Components (MS44xB VNA) Table. ME7A4 Multiport Rear Panel Cable Connections (MS44xB) ( of ) Index Part Number Cable Description Connection From Connection To 4-0 a SMA male-male - a SMA male-male -0 a SMA male-male 7 - a SMA male-male -0 a SMA male-male 9 MS44xB VNA 0 MN49xC Test Set 7B Test Set 79C Test Set MS44xB port P source loop in MS44xB port b loop out MS44xB port b loop in MS44xB port P source loop out MS44xB port P source loop in MN49xC port TO VNA Port Src INPUT MN49xC port TO VNA b OUTPUT MN49xC port TO VNA b INPUT a. Tighten each cable in this group using an mm (/ in) torque end wrench set to 0.9 N m ( lbf in). MN49xC port TO VNA Port Src OUTPUT MN49xC port TO VNA Port Src INPUT VectorStar ME7A4 QSG PN: Rev. A QSG-9

10 4. Semi-rigid Cable Connections Between System Components 4. Semi-rigid Cable Connections Between System Components Make the cable connections as shown in Figure 4 or Figure, and in Table. If your system has Option 0 Dual Source Architecture (MS44xB only), use Figure 4. If your system does not have Option 0, use Figure. Frequency Calibration Power Measurement Sweep Application Channel Avg System Response 7 Trace Display File Help Scale Marker Preset Standby Operate ALL PORTS: CAUTION +7 dbm MAX AVOID STATIC DISCHARGE 4 RF LO Out In In Out 9 Install Termination Removed from VNA RF or RF 0 Figure 4 ME7A4 Multiport Semi-rigid Cable Connections (with Option 0 Dual Source Architecture) QSG-0 PN: Rev. A VectorStar ME7A4 QSG

11 4. Semi-rigid Cable Connections Between System Components Frequency Calibration Power Measurement Sweep Application Channel Avg System Response File 7 Trace Display Scale Help Marker Preset Standby Operate ALL PORTS: CAUTION +7 dbm MAX AVOID STATIC DISCHARGE RF LO Out In In Out Figure ME7A4 Multiport Cable Connections (No Option 0) VectorStar ME7A4 QSG PN: Rev. A QSG-

12 4. Semi-rigid Cable Connections Between System Components Table. ME7A4 Multiport Cable Interconnect Part Numbers and Locations ( of ) Index Part Numbers Description/Torque Connection From Connection To V (m-m) (MN497C) -77- K (m-m) (MN494C) (With Option 0) 77- (No Option 0) 77-9 Front Panel RF Cable (4 each) V or K male-male Tighten using an mm (/ in) torque end wrench set to 0.9 N m ( lbf in). Front Panel RF Cable K male-male Tighten using an mm (/ in) torque end wrench set to 0.9 N m ( lbf in). Front Panel LO Cable ( each) K male-male Tighten using an mm (/ in) torque end wrench set to 0.9 N m ( lbf in). Front Panel RF Cable K male-male Tighten using an mm (/ in) torque end wrench set to 0.9 N m ( lbf in). Front Panel LO Cable ( each) K male-male Tighten using an mm (/ in) torque end wrench set to 0.9 N m ( lbf in). b (In) b (Out) Port Source (In) Port Source (Out) Port Source (In) Port Source (Out) b (In) b (Out) RF (Figure 4) (With Option 0) RF (Figure ) (No Option 0) LO LO RF (Figure 4) (With Option 0) 7B Test Set port RF Out (Figure ) (No Option 0) 7B Test Set port LO Out 7B Test Set port LO Out MN49xC port b (In) MN49xC port b (Out) MN49xC port Port Source (In) MN49xC port Port Source (Out) MN49xC port Port Source (In) MN49xC port Port Source (Out) MN49xC port b (In) MN49xC port b (Out) 7B Test Set port RF In 7B Test Set port RF In 7B Test Set port LO In 7B Test Set port LO In 79C Test Set port RF 79C Test Set port RF 79C Test Set port LO 79C Test Set port LO QSG- PN: Rev. A VectorStar ME7A4 QSG

13 4. Semi-rigid Cable Connections Between System Components Table. ME7A4 Multiport Cable Interconnect Part Numbers and Locations ( of ) Index Part Numbers Description/Torque Connection From Connection To V0 7 MS44xA VNA MS44xB VNA MS447A VNA MS447B VNA MN494C Test Set MN497C Test Set 9 7B Test Set 0 79C Test Set Termination (With Option 0) Tighten using an mm (/ in) torque end wrench set to 0.9 N m ( lbf in). Option 0, 0, or 0, and 0x (Banded) Option 0, 0, or 0, and 0x (Banded) Option 0, 0, or 0, and 0x (Broadband) Option 0, 0, or 0, and 0x (Broadband) (Banded) (Broadband) Remove from VNA port RF or RF (With Option 0) Add to 7B Test Set port RF Out VectorStar ME7A4 QSG PN: Rev. A QSG-

14 . Front Panel Cable Connections. Front Panel Cable Connections Make the cable connections as shown in Figure and in Table 4. 9 ALL PORTS: CAUTION +7 dbm MAX AVOID STATIC DISCHARGE 0 4 RF LO Out In Port 7 In Out Port 4 Port Port Port Module Port Module Test Port to Module SRC (74A only) Test Port to Module SRC (74A only) Port Module 7 Port 4 Module Test Port to Module SRC (74A only) 4 Test Port 4 to Module SRC (74A only) Figure Front Panel to mm-wave Module Connections QSG-4 PN: Rev. A VectorStar ME7A4 QSG

15 . Front Panel Cable Connections Note The cables for Test Port through Test Port 4 to Module SRC are not used with mm-wave modules 744A-EE, 744A-EW, or 744A-Rx. Table 4. ME7A4 Cable Interconnect Part Numbers and Locations ( of ) Index Part Number Description Connection From Connection To a,b Coaxial Phase Stable Cable (4 each) V male-female flexible, in Used with 74A Broadband Modules only Tighten at Test Set using an mm (/ in) torque end wrench set to 0.9 N m ( lbf in). MN49xC port Port Port Port Port 4 74A port (Port Module) SRC (Port Module) SRC (Port Module) SRC (Port 4 Module) SRC 7 7- a mm-wave Module Interface Cables (for 74A, 744A-EE, 744A-EW modules) Group of cables for each port Tighten at Test Set using an mm (/ in) torque end wrench set to 0.9 N m ( lbf in). 79C Test Set: Port, Port RF, LO, Test, Ref, Power/Signal 7B Test Set Port, Port (Port, Port 4) RF, LO, Test, Ref, Power/Signal mm-wave Modules: Port, Port Modules RF, LO, Test, Ref, Power/Signal mm-wave Modules Port, Port 4 Modules RF, LO, Test, Ref, Power/Signal OML Module Interface Cables Group of 4 cables for each port 79C Test Set Port, Port RF, LO, Test, Ref OML Modules Port, Port Modules RF, LO, Test IF, Ref IF 7 7- a Tighten at Test Set using an mm (/ in) torque end wrench set to 0.9 N m ( lbf in). VDI Module Interface Cables Group of 4 cables for each port Tighten at Test Set using an mm (/ in) torque end wrench set to 0.9 N m ( lbf in). 7B Test Set Port, Port (Port, Port 4) RF, LO, Test, Ref 79C Test Set Port, Port RF, LO, Test, Ref 7B Test Set Port, Port (Port, Port 4) RF, LO, Test, Ref OML Modules Port, Port 4 Modules RF, LO, Test IF, Ref IF VDI Modules Port, Port Modules RF Input, LO Input, Meas. IF, Ref IF VDI Modules Port, Port 4 Modules RF Input, LO Input, Meas. IF, Ref IF 7 7- a mm-wave Module Interface Cables (for 744A-Rx modules) Group of cables for each port Tighten at Test Set using an mm (/ in) torque end wrench set to 0.9 N m ( lbf in). 79C Test Set Port, Port LO, Test, Power/Signal 7B Test Set Port, Port (Port, Port 4) LO, Test, Power/Signal Rx Modules Port, Port Modules LO, Test, Power/Signal Rx Modules Port, Port 4 Modules LO, Test, Power/Signal VectorStar ME7A4 QSG PN: Rev. A QSG-

16 . Front Panel Cable Connections Table 4. ME7A4 Cable Interconnect Part Numbers and Locations ( of ) Index Part Number Description Connection From Connection To 9 MS44xA VNA - Option 0, 0, or 0, and 0x (Banded) MS44xB VNA - Option 0, 0, or 0, and 0x (Banded) MS447A VNA - Option 0, 0, or 0, and 0x (Broadband) MS447B VNA - Option 0, 0, or 0, and 0x (Broadband) 0 MN494C Test Set (Banded) MN497C Test Set (Broadband) 7B Test Set 79C Test Set a. Do not yet connect the cable ends to the Millimeter-Wave modules. Module connection instructions follow this section. b. Cable 0-09 Coaxial Phase Stable Cable is not included or required when using the 744A-EE, 744A-EW mm-wave modules, or the 744A-Rx Receiver Module. QSG- PN: Rev. A VectorStar ME7A4 QSG

17 . Front Panel to Millimeter-Wave Module Connections. Front Panel to Millimeter-Wave Module Connections Connect the 7B and 79C Broadband Test Set test port cables to the 74A, 744A-EE, 744A-EW, or 744A-Rx Modules as shown below, observing the correct torque limits for each connector. See Figure 7 and Table. Route the cable assemblies through the module cable restraint. Note It is easier to first connect the cables to the module and then mount the module in its bracket. Observe torque instructions where indicated. Each module (except the 744A-Rx) is characterized for a specific VNA Serial Number and VNA Test Port as designated on the module port assignment label. Ensure the module matches the correct VNA and Test Set port. For more detailed information on the modules including DUT Waveguide (WG) connection alignment and custom bracket mounting, refer to VectorStar Broadband/Banded Millimeter-Wave Modules Reference Manual. Inverting a Module If necessary, a module can be turned over in the bracket to change the elevation of the W connector. To turn the module over:. Remove the six knurled head thumbscrews from the module.. Turn the module over.. Install the six thumbscrews. TEST 4 REF Power/Signal LO 7 9 RF SRC 74A LO SRC (Not used) RF 74A 0 TEST TEST REF (Not used) Power/Signal Power/Signal REF 744A-EE, 744A-EW LO 744A-Rx (Not used) RF SRC (Not used) Figure 7 Millimeter-Wave Module Connections VectorStar ME7A4 QSG PN: Rev. A QSG-7

18 . Front Panel to Millimeter-Wave Module Connections Table. Millimeter-Wave Module Connections Index Cable P/N Description N/A Millimeter-Wave Module in bracket N/A W - mm Connector (74A, 744A-Rx modules) Tighten using a torque end wrench and a plain end wrench mm Torque End Wrench set to 0.4 N m (4 lbf in). Recommended is Anritsu mm / 7 mm Open End Wrench. Recommended is Anritsu 0-0. WR-0 or WR- Adapter - mm connector (744A-EE, 744A-EW modules) Use Waveguide Adapter Toolkits (7494-, 7494-, or ). Tighten using a torque end wrench and a plain end wrench. mm Torque End Wrench set to 0.4 N m (4 lbf in). Recommended is Anritsu mm / 7 mm Open End Wrench. Recommended is Anritsu 0-0. TEST - SSMC Connector (74A, 744A-EE, 744A-EW, and 744A-Rx modules) Tighten using a 4 mm (/ in) torque end wrench set to less than 0. N m ( lbf in). Recommended is Anritsu 0- torque wrench. 7- a REF - SSMC Connector (74A, 744A-EE, and 744A-EW modules) 4 Tighten using a 4 mm (/ in) torque end wrench set to less than 0. N m ( lbf in). or Recommended is Anritsu 0- torque wrench. 7- b,c Power/Signal Bi-Lobe Connector (74A, 744A-EE, 744A-EW, 744A-Rx) LO - K Connector (74A, 744A-EE, 744A-EW, and 744A-Rx modules) Tighten using an mm (/ in) torque end wrench set to 0.9 N m ( lbf in). Recommended is Anritsu Module Power and I/O Cable Restraint 0-09 d Tighten using an mm (/ in) torque end wrench set to 0.9 N m ( lbf in). SRC - V Connector (74A module only) Recommended is Anritsu a Tighten using an mm (/ in) torque end wrench set to 0.9 N m ( lbf in). RF - V Connector (74A, 744A-EE, and 744A-EW modules) Recommended is Anritsu N/A Factory Calibrated Port Assignment Label N/A Module Serial Number Label a. 74A, 744A-EE, and 744A-EW modules use cable assembly 7-. b. The REF cable is not used in the 7- cable assembly. c. 744A-Rx module uses cable assembly 7-. d. Cable 0-09 Coaxial Phase Stable Cable is used only with the 74A modules. Millimeter-Wave Module Operating Environment The following notes should be observed when operating the 74A and 744A-xx mm-wave Modules: Thermal heat sinking similar to the supplied mounting brackets of the Millimeter-Wave Module should be considered in custom mounting applications. Each 74A Module consumes a maximum of watts. Each 744A-EE and 744A-EW Module consumes a maximum of watts. Each 744A-Rx Module consumes a maximum of 7 watts. The primary heat sink paths for the module is the two side mounting surfaces of the mounting bracket. With the attached cable mounting brackets, the case temperature rise is approximately C to 0 C above ambient. A three () Year warranty is valid for all versions of 744A and 74A modules, with or without mounting brackets attached. QSG- PN: Rev. A VectorStar ME7A4 QSG

19 7. Front Panel to OML/VDI Module Connections 7. Front Panel to OML/VDI Module Connections Connect the front panel cables between the 7B and 79C Test Sets, and the OML or VDI frequency extension modules as shown in Figure, Figure 9, and Figure 0, and as described in Table, Table 7, and Table. Caution To avoid connector damage, observe torque requirements where indicated. ALL PORTS: CAUTION +7 dbm MAX AVOID STATIC DISCHARGE RF LO Out In In Out Port Port 4 7 Port Port Port Module Port Module Port RF, LO, Test, Ref to OML/VDI Module Port RF, LO, Test, Ref to OML/VDI Module Port Module 4 Port 4 Module Port RF, LO, Test, Ref to OML/VDI Module Port 4 RF, LO, Test, Ref to OML/VDI Module Figure Cable Connections between 7B, 79C Test Sets, and OML or VDI Frequency Extension Modules VectorStar ME7A4 QSG PN: Rev. A QSG-9

20 7. Front Panel to OML/VDI Module Connections Table. ME7A4 OML/VDI Cable Interconnect Part Numbers and Locations Index Part Number Description Connection From Connection To 4 7- ( each) 7- ( each) MN49xC Test Set 7B Test Set 7 79C Test Set OML Module Interface Cable Assembly Group of 4 cables for each port OML Module Interface Cable Assembly Group of 4 cables for each port VDI Module Interface Cables Assembly Group of 4 cables for each port VDI Module Interface Cables Assembly Group of 4 cables for each port 79C Test Set Port, Port Ref RF LO Test 7B Test Set Port, Port (Port, Port 4) Ref RF LO Test 79C Test Set Port, Port RF Ref Test LO 7B Test Set Port, Port (Port, Port 4) RF Ref Test LO OML Modules: Port, Port Modules Ref IF RF Input LO Input Test IF OML Modules: Port, Port 4 Modules Ref IF RF Input LO Input Test IF VDI Modules: Port, Port Modules RF Input Ref. IF Meas. IF LO Input VDI Modules: Port, Port 4 Modules RF Input Ref. IF Meas. IF LO Input QSG-0 PN: Rev. A VectorStar ME7A4 QSG

21 7. Front Panel to OML/VDI Module Connections From ME7-79C Test Set Port, Port From ME7-7B Test Set Port, Port 4 Ref RF 4 LO Test OML Frequency Extension Modules (Typical) Ref RF LO Test Ref IF RF Input DC Power LO Input Test IF Ref IF RF Input DC Power LO Input Test IF OML Power Supply OML Power Supply Figure 9 VNA/ Test Set Cable Connections to OML Modules Table 7. OML Module Connections Index Cable P/N Description N/A OML Module 4 7- Ref IF - SMA Connector Tighten using an mm (/ in) torque end wrench set to 0.9 N m ( lbf in). Recommended is Anritsu 0-0. RF Input - SMA Connector Tighten using an mm (/ in) torque end wrench set to 0.9 N m ( lbf in). Recommended is Anritsu 0-0. LO Input - SMA Connector Tighten using an mm (/ in) torque end wrench set to 0.9 N m ( lbf in). Recommended is Anritsu 0-0. Test IF - SMA Connector Tighten using an mm (/ in) torque end wrench set to 0.9 N m ( lbf in). Recommended is Anritsu 0-0. N/A OML Module Power Supply Connector VectorStar ME7A4 QSG PN: Rev. A QSG-

22 7. Front Panel to OML/VDI Module Connections From ME7-79C Test Set Port, Port From ME7-7B Test Set Port, Port 4 RF Ref Test 4 LO VDI VNA Extender Modules (Typical) RF Ref Test LO RF Input Ref. IF Power Meas. IF LO Input RF Input Ref. IF Power Meas. IF LO Input VDI Power Supply VDI Power Supply Figure 0 VNA/ Test Set Cable Connections to VDI Modules Table. VDI Module Connections Index Cable P/N Description N/A VDI Module 4 a 7- RF Input - K (.9 mm) Connector Tighten using an mm (/ in) torque end wrench set to 0.9 N m ( lbf in). Recommended is Anritsu 0-0. Ref. IF - SMA Connector Tighten using an mm (/ in) torque end wrench set to 0.9 N m ( lbf in). Recommended is Anritsu 0-0. Meas. IF - SMA Connector Tighten using an mm (/ in) torque end wrench set to 0.9 N m ( lbf in). Recommended is Anritsu 0-0. LO Input- K (.9 mm) Connector Tighten using an mm (/ in) torque end wrench set to 0.9 N m ( lbf in). Recommended is Anritsu 0-0. VDI Module Power Supply Connector a.the VDI module connectors may differ slightly than on the illustration shown above. For example, depending on the model and date built, the power supply connector may be round instead of rectangular. QSG- PN: Rev. A VectorStar ME7A4 QSG

23

24 Anritsu utilizes recycled paper and environmentally conscious inks and toner. Anritsu Company 490 Jarvis Drive Morgan Hill, CA USA

VectorStar ME7838A Broadband/Banded Millimeter-Wave System

VectorStar ME7838A Broadband/Banded Millimeter-Wave System Established 1981 Advanced Test Equipment Rentals www.atecorp.com 800-404-ATEC (2832) Installation Guide VectorStar ME7838A Broadband/Banded Millimeter-Wave System High Performance Modular Broadband/Banded

More information

VectorStar Broadband/Banded Millimeter-Wave Modules

VectorStar Broadband/Banded Millimeter-Wave Modules Reference Manual VectorStar Broadband/Banded Millimeter-Wave Modules MA253A Broadband Millimeter-Wave Module 3743A Broadband Millimeter-Wave Module 3743E Broadband Millimeter-Wave Module 3744A-EE Banded

More information

VectorStar ME7828A Series Broadband/Millimeter Wave System

VectorStar ME7828A Series Broadband/Millimeter Wave System Installation Guide VectorStar ME7828A Series Broadband/Millimeter Wave System High Performance Vector Network Analysis Measurement System from 10 MHz to 110 GHz Anritsu Company 490 Jarvis Drive Morgan

More information

R System Verification Software (SVS)

R System Verification Software (SVS) Quick Start Guide 2300-533-R System Verification Software (SVS) MS2026B and MS2028B VNA Master MS2026C, MS2027C, MS2028C, MS2036C, MS2037C, MS2038C VNA Master SC7858 Verification Kit, N Connectors SC7859

More information

Direct Connection of OML Frequency Extenders to Keysight s PNA-C (E836xC) VNA for 1-Path 2-Port S-Parameter Measurements

Direct Connection of OML Frequency Extenders to Keysight s PNA-C (E836xC) VNA for 1-Path 2-Port S-Parameter Measurements Direct Connection of OML Frequency Extenders to Keysight s PNA-C (E836xC) VNA for 1-Path 2-Port S-Parameter Measurements Introduction For full two-port S-parameter measurements to extend PNA-C vector network

More information

Agilent PNA Series Microwave Network Analyzers

Agilent PNA Series Microwave Network Analyzers Agilent PNA Series Microwave Network Analyzers Configuration Guide PNA-L N5230A PNA-L N5230A PNA E8362B PNA E8363B PNA E8364B PNA E8361A PNA N5250A 300 khz to 6, 13.5, or 20 GHz 10 MHz to 20, 40, or 50

More information

Agilent ENA-L RF Network Analyzers

Agilent ENA-L RF Network Analyzers Agilent ENA-L RF Network Analyzers Configuration Guide E5061A E5062A 300 khz to 1.5 GHz 300 khz to 3 GHz This configuration guide describes standard configurations, options, accessories and peripherals

More information

Keysight N9030A Signal Analyzer Option BBA Analog Baseband IQ Inputs Retrofit Kit

Keysight N9030A Signal Analyzer Option BBA Analog Baseband IQ Inputs Retrofit Kit Keysight N9030A Signal Analyzer Option BBA Analog Baseband IQ Inputs Retrofit Kit Notice: This document contains references to Agilent. Please note that Agilent s Test and Measurement business has become

More information

Agilent PNA Series Microwave Network Analyzers

Agilent PNA Series Microwave Network Analyzers Agilent PNA Series Microwave Network Analyzers Configuration Guide PNA-L N5230A PNA-L N5230A PNA-X N5242A PNA E8362B PNA E8363B PNA E8364B PNA E8361A PNA N5250A 300 khz to 6, 13.5, or 20 GHz 10 MHz to

More information

Installation Note. Agilent Technologies 85105A Option 50 Installation Instructions for RF Switch Replacement Kit

Installation Note. Agilent Technologies 85105A Option 50 Installation Instructions for RF Switch Replacement Kit Installation Note Agilent Technologies 85105A Option 50 Installation Instructions for RF Switch Replacement Kit 85105-60047 Part Number 85105-90023 Printed in USA August 2002 Notice. The information contained

More information

Keysight Technologies PNA Series Microwave Network Analyzers

Keysight Technologies PNA Series Microwave Network Analyzers Keysight Technologies PNA Series Microwave Network Analyzers Configuration Guide PNA-L N5230A PNA-L N5230A PNA-X N5242A PNA E8362B PNA E8363B PNA E8364B PNA E8361A PNA N5250A 300 khz to 6, 13.5, or 20

More information

Installation Note. IF Access Upgrade Kit. For PNA Series Microwave Network Analyzers. Network Analyzer Model Number. Upgrade Kit Part Number

Installation Note. IF Access Upgrade Kit. For PNA Series Microwave Network Analyzers. Network Analyzer Model Number. Upgrade Kit Part Number Installation Note IF Access Upgrade Kit For PNA Series Microwave Network Analyzers Network Analyzer Model Number E8361A/C, E8362B/C, E8363B/C, E8364B/C Upgrade Kit Part Number E8362-60116 Agilent Part

More information

Agilent Upgrade Guide for the 8510 Vector Network Analyzer Product Note

Agilent Upgrade Guide for the 8510 Vector Network Analyzer Product Note Agilent Upgrade Guide for the 8510 Vector Network Analyzer Product Note Discontinued Product Information For Support Reference Only Information herein, may refer to products/services no longer supported.

More information

Cisco CRS 3-Phase AC Power Distribution Unit Installation Guide 2. Cisco CRS 3-Phase AC Power Distribution Unit 2

Cisco CRS 3-Phase AC Power Distribution Unit Installation Guide 2. Cisco CRS 3-Phase AC Power Distribution Unit 2 Cisco CRS 3-Phase AC Power Distribution Unit Installation Guide Cisco CRS 3-Phase AC Power Distribution Unit Installation Guide 2 Cisco CRS 3-Phase AC Power Distribution Unit 2 Revised: November 18, 2016,

More information

Keysight Technologies Millimeter Wave Network Analyzers (N5290A/N5291A) Configuration Guide

Keysight Technologies Millimeter Wave Network Analyzers (N5290A/N5291A) Configuration Guide Keysight Technologies Millimeter Wave Network Analyzers (N5290A/N5291A) Configuration Guide 02 Keysight Millimeter Wave Network Analyzers (N5290A/N5291A) - Cofiguration Guide Table of Contents Introduction...

More information

Extended Frequency Range Upgrade Kit (50 GHz to 67 GHz)

Extended Frequency Range Upgrade Kit (50 GHz to 67 GHz) Installation Note Extended Frequency Range Upgrade Kit (50 GHz to 67 GHz) Upgrade Kit Number: E8364-60105 For E8364B/C Microwave Network Analyzers WITHOUT the Configurable Test Set Option (Option 014)

More information

Agilent 85130C NMD 3.5 mm to Type-N Adapter Kit

Agilent 85130C NMD 3.5 mm to Type-N Adapter Kit Agilent 85130C NMD 3.5 mm to Type-N Adapter Kit Operating and Service Manual Agilent Technologies Notices Agilent Technologies, Inc. 1987, 2004, 2008 No part of this manual may be reproduced in any form

More information

Installation Note. Source Attenuators and Bias Tees Upgrade Kit. For E8362B/C PNA Series Microwave Network Analyzers. Network Analyzer Model Number

Installation Note. Source Attenuators and Bias Tees Upgrade Kit. For E8362B/C PNA Series Microwave Network Analyzers. Network Analyzer Model Number Installation Note Source Attenuators and Bias Tees Upgrade Kit For E8362B/C PNA Series Microwave Network Analyzers Network Analyzer Model Number Upgrade Kit Part Number E8362B/C E8362-60115 Agilent Part

More information

PXI Vector Network Analyzer

PXI Vector Network Analyzer CONFIGURATION GUIDE PXI Vector Network Analyzer M9370A 300 khz to 4 GHz M9371A 300 khz to 6.5 GHz M9372A 300 khz to 9 GHz M9373A 300 khz to 14 GHz M9374A 300 khz to 20 GHz M9375A 300 khz to 26.5 GHz Drive

More information

Software User s Guide

Software User s Guide Model 360X/372XXA Vector Network Analyzer Performance Verification Software Software User s Guide Software Revision 1.03 This manual applies to the WILTRON 360X/372XXA Vector Network Analyzer Performance

More information

Keysight 85130F NMD 2.4 mm to 3.5 mm Adapter Kit

Keysight 85130F NMD 2.4 mm to 3.5 mm Adapter Kit Keysight 85130F NMD 2.4 mm to 3.5 mm Adapter Kit Operating and Service Manual Notices Keysight Technologies 1988-2015 No part of this manual may be reproduced in any form or by any means (including electronic

More information

Lightning 37xxxE Series Vector Network Analyzer

Lightning 37xxxE Series Vector Network Analyzer Maintenance Manual Lightning 37xxxE Series Vector Network Analyzer Lightning 37247E VNA, K Connectors, 40.0 MHz to 20.0 GHz, Passive Measurements Lightning 37347E VNA, K Connectors, 40.0 MHz to 20.0 GHz,

More information

Installation Note. Enhanced Memory Upgrade Kit (Option B72) for Agilent ESA-E Series and ESA-L Series Spectrum Analyzers

Installation Note. Enhanced Memory Upgrade Kit (Option B72) for Agilent ESA-E Series and ESA-L Series Spectrum Analyzers Installation Note Enhanced Memory Upgrade Kit (Option B72) for Agilent ESA-E Series and ESA-L Series Spectrum Analyzers Part Number E4401-90498 Supersedes: E4401-90332 Printed in USA July 2005 Notice.

More information

Model 4200-CVU-PWR. Parts Package. Introduction. PA-977 Rev. C / September 2016 *PPA-977C* 1

Model 4200-CVU-PWR. Parts Package. Introduction. PA-977 Rev. C / September 2016 *PPA-977C* 1 Keithley Instruments 28775 Aurora Road Cleveland, Ohio 44139 1-800-935-5595 http://www.tek.com/keithley Model 4200-CVU-PWR Parts Package Introduction The Model 4200-CVU-PWR C-V Power Package for both the

More information

Keysight 85130D NMD 3.5 mm to 3.5 mm Adapter Kit

Keysight 85130D NMD 3.5 mm to 3.5 mm Adapter Kit Keysight 85130D NMD 3.5 mm to 3.5 mm Adapter Kit Operating and Service Manual Notices Keysight Technologies 1987-2015 No part of this manual may be reproduced in any form or by any means (including electronic

More information

Agilent RF Network Analyzers PNA Series

Agilent RF Network Analyzers PNA Series Agilent RF Network Analyzers PNA Series Configuration Guide E8356A E8357A E8358A 300 khz to 3 GHz 300 khz to 6 GHz 300 khz to 9 GHz System Configuration Summary This summary lists the main components required

More information

Keysight Second Source, Combiner, and Mechanical Switches Upgrade Kit

Keysight Second Source, Combiner, and Mechanical Switches Upgrade Kit Keysight Second Source, Combiner, and Mechanical Switches Upgrade Kit To Upgrade PNA-X N5241A, N5242A, or N5249A Option 419 to Option 423 Upgrade Kit Order Number: N5241AU- 927, N5242AU- 927, and N5249AU-

More information

Quick Start. This document describes how to install the Juniper Networks PTX5000 Packet Transport

Quick Start. This document describes how to install the Juniper Networks PTX5000 Packet Transport PTX5000 Packet Transport Router Quick Start September 2017 Part Number: 530-066788 Revision 01 This document describes how to install the Juniper Networks PTX5000 Packet Transport Router. Contents Quick

More information

ATEC (2832) Models 8757A, 85027A/B/C, 85020A/B

ATEC (2832) Models 8757A, 85027A/B/C, 85020A/B Established 1981 Advanced Test NETWORK Equipment ANALYZERS Rentals 8757/8756 System Accessories wwwatecorpcom 800-404-ATEC (2832) Models 8757A, 85027A/B/C, 85020A/B UP]] HP 8757A Specifications Amplitude

More information

Series 8900 LAN. Operation Manual. Part Number (example configuration) Part Number (example configuration)

Series 8900 LAN. Operation Manual. Part Number (example configuration) Part Number (example configuration) Series 8900 LAN Part Number 90570300 (example configuration) Part Number 90570300-001 (example configuration) Operation Manual Operation Manual, Part Number 07508900-001, Rev. B, February 26, 2013 All

More information

NV1000 Terminal Equipment Operations Manual Introduction. Manual Part No. MI February, 1996

NV1000 Terminal Equipment Operations Manual Introduction. Manual Part No. MI February, 1996 Nvision@ NV1000 Terminal Equipment Operations Manual Introduction CONTENTS 1. MANUAL DESCRIPTION 2. OVERVIEW 3. POWER AND THERMAL CONSIDERATIONS 4. INSTALLATION Manual Part No. MI1000-01 February, 1996

More information

Model 2657A-LIM-3 LO Interconnect Module

Model 2657A-LIM-3 LO Interconnect Module Keithley Instruments, Inc. 28775 Aurora Road Cleveland, Ohio 44139 1-888-KEITHLEY http://www.keithley.com Model 2657A-LIM-3 LO Interconnect Module User's Guide Description The Model 2657A-LIM-3 LO Interconnect

More information

Keysight Second Source, Combiner, and Mechanical Switches Upgrade Kit

Keysight Second Source, Combiner, and Mechanical Switches Upgrade Kit Keysight Second Source, Combiner, and Mechanical Switches Upgrade Kit To Upgrade PNA-X N5241A or N5242A Option 219 to Option 224 For Analyzers with Serial Numbers Prefixed MY/SG/ US5201 and Above Upgrade

More information

Keysight Technologies N9020B MXA Signal Analyzer

Keysight Technologies N9020B MXA Signal Analyzer Keysight Technologies N9020B MXA Signal Analyzer Analog Baseband IQ Inputs (Option BBA) Upgrade Kit Notice: This document contains references to Agilent. Please note that Agilent s Test and Measurement

More information

Installation Note. Configurable Test Set Upgrade Kit. For PNA Series RF Network Analyzers (E8801A, E8802A, and E8803A) Network Analyzer Model Number

Installation Note. Configurable Test Set Upgrade Kit. For PNA Series RF Network Analyzers (E8801A, E8802A, and E8803A) Network Analyzer Model Number Installation Note Configurable Test Set Upgrade Kit For PNA Series RF Network Analyzers (E8801A, E8802A, and E8803A) Network Analyzer Model Number Upgrade Kit Part Number E8801A, E8802A, E8803A E8801-60103

More information

Agilent ENA RF Network Analyzer

Agilent ENA RF Network Analyzer Agilent ENA RF Network Analyzer Configuration Guide E5071C E5091A 9 khz to 4.5 GHz 100 khz to 4.5 GHz (with bias tees) 9 khz to 8.5 GHz 100 khz to 8.5 GHz (with bias tees) Multiport test set This configuration

More information

S-Band Redundant LNA Systems

S-Band Redundant LNA Systems S-Band Redundant LNA Systems LRS-1000 Series Introduction Redundant LNA systems minimize system downtime due to LNA failure by providing a spare LNA and an automatic means of switching to the spare upon

More information

RF Characterization Report

RF Characterization Report RF058 Series Cable Assemblies RF058-01BJ1-01BJ1-0150 RF058-01SB1-01SB1-0150 RF058-01SP1-01SP1-0150 Description: RF Cable Assembly, 50Ohm, RG058 Coaxial Cable Samtec Inc. WWW.SAMTEC.COM Phone: 812-944-6733

More information

Model GHz 50 Ohm RF Module

Model GHz 50 Ohm RF Module Keithley Instruments 28775 Aurora Road Cleveland, Ohio 44139 1-800-935-5595 tek.com/keithley Model 7711 2 GHz 50 Ohm RF Module Instructions for use with DAQ6510 Introduction The 7711 plug-in module provides

More information

Keithley Instruments Customer Documentation Series 2600A UL Safety Supplement

Keithley Instruments Customer Documentation Series 2600A UL Safety Supplement Keithley Instruments, Inc. 28775 Aurora Road Cleveland, Ohio 44139 1-888-KEITHLEY www.keithley.com Keithley Instruments Customer Documentation Series 2600A UL Safety Supplement 1. Introduction The Keithley

More information

Ku-Band Solid-State Power Amplifier

Ku-Band Solid-State Power Amplifier PKM14S200R Ku-Band Solid-State Power Amplifier This high power solid-state amplifier offers an output power of 200 watts across the standard 14.0 to 14.5 GHz satellite uplink band. Built for reliable,

More information

LevelOne. KVM-0115/KVM / 17-inch LCD KVM Rack Console. User Manual. Version

LevelOne. KVM-0115/KVM / 17-inch LCD KVM Rack Console. User Manual. Version LevelOne KVM-0115/KVM-0117 15 / 17-inch LCD KVM Rack Console User Manual Version 1.0-1305 1 SAFETY INSTRUCTIONS 1. Please read these safety instructions carefully. 2. Please keep this User Manual for later

More information

SERIES MS462XX VECTOR NETWORK MEASUREMENT SYSTEM VERIFICATION KITS OPERATION AND MAINTENANCE MANUAL

SERIES MS462XX VECTOR NETWORK MEASUREMENT SYSTEM VERIFICATION KITS OPERATION AND MAINTENANCE MANUAL SERIES MS462XX VECTOR NETWORK MEASUREMENT SYSTEM VERIFICATION KITS OPERATION AND MAINTENANCE MANUAL 490 JARVIS DRIVE l MORGAN HILL, CA 95037-2809 P/N: 10100-00036 REVISION: A PRINTED: MAY 1999 COPYRIGHT

More information

Agilent. E5092A Configurable Multiport Test Set. Configuration Guide

Agilent. E5092A Configurable Multiport Test Set. Configuration Guide Agilent E5071C Network Analyzer 9 khz to 4.5 GHz 100 khz to 4.5 GHz (with bias tees) 9 khz to 8.5 GHz 100 khz to 8.5 GHz (with bias tees) 300 khz to 20 GHz (with bias tees) E5092A Configurable Multiport

More information

5 Performance Verification

5 Performance Verification 5 Performance Verification Performance Verification TEST EQUIPMENT REQUIRED This procedure can be used to verify the warranted characteristics of the CP015 Current Probe. The recommended calibration interval

More information

Instruction Manual Model Block Translator

Instruction Manual Model Block Translator Instruction Manual Model 2083-1010 Block Translator May 2018, Rev. 0 1250>1200 G=-10.0 REF = AUTO - I MENU MODEL 2083 TRANSLATOR CROSS TECHNOLOGIES INC. REMOTE POWER ALARM EXECUTE Data, drawings, and other

More information

LASER PLUS OPERATING INSTRUCTIONS

LASER PLUS OPERATING INSTRUCTIONS LASER PLUS OPERATING INSTRUCTIONS Phone: (209) 586-1022 (800) 545-1022 Fax: (209) 586-1026 E-Mail: salessupport@olsontech.com 025-370403 REV X9 www.olsontech.com 12/16/03 TABLE OF CONTENTS SYSTEM OVERVIEW

More information

Precision N Coaxial Calibration Kit

Precision N Coaxial Calibration Kit User Guide Precision N Coaxial Calibration Kit DC to 18 GHz Models: 8850CK10/11 8850CK20/21 8850-511 (A) 3/15 User Guide Precision N Coaxial Calibration Kit DC to 18 GHz Models: 8850CK10/11 8850CK20/21

More information

C-Band Solid-State Power Amplifiers

C-Band Solid-State Power Amplifiers PCD6S350R, PCD6S400R C-Band Solid-State Power Amplifiers These high power solid-state amplifiers offer output powers of 350 or 400 watts across the standard 5.850 to 6.425 GHz satellite uplink band. Built

More information

Installing the Cisco 2524 and Cisco 2525 Routers

Installing the Cisco 2524 and Cisco 2525 Routers CHAPTER 3 Installing the Cisco 2524 and Cisco 2525 Routers This chapter guides you through the installation of the Cisco 2524 and Cisco 2525 routers and includes the following sections: Required Tools

More information

User Manual VX4234 Digital Multimeter Module

User Manual VX4234 Digital Multimeter Module User Manual VX4234 Digital Multimeter Module 070-9139-02 This document applies for firmware version 1.00 and above. General Safety Summary Review the following safety precautions to avoid injury and

More information

EMSwitch RF Switch Plug-In Card

EMSwitch RF Switch Plug-In Card EMSwitch RF Switch Plug-In Card User Manual Model 7001-001 Model 7001-003 Model 7001-002 (not all models shown; Model 7001-004 External Switch Box not shown) ETS-Lindgren Inc. reserves the right to make

More information

Series 8000 RF Signal Switch Solution

Series 8000 RF Signal Switch Solution RF Signal Switch Solution Operation Manual Operation Manual, Part Number 07508000 006, Rev. B, Oct 7, 2014 All technical data and specifications in this publication are subject to change without prior

More information

Series 8000 RF Signal Switch Solution

Series 8000 RF Signal Switch Solution RF Signal Switch Solution Operation Manual Operation Manual, Part Number 07508000-006, Rev. A, May 17, 2013 All technical data and specifications in this publication are subject to change without prior

More information

Modular Block Converter Systems

Modular Block Converter Systems SATCOM Technologies Modular Block Converter Systems C-Band Hot-swappable, plug-in upconverter and downconverter modules Dual, redundant, hot-swappable power supplies Excellent frequency stability over

More information

Agilent. E5071C Network Analyzer 9 khz to 4.5/6.5/8.5 GHz 100 khz to 4.5/6.5/8.5 GHz (with bias tees) 300 khz to 14/20 GHz (with bias tees)

Agilent. E5071C Network Analyzer 9 khz to 4.5/6.5/8.5 GHz 100 khz to 4.5/6.5/8.5 GHz (with bias tees) 300 khz to 14/20 GHz (with bias tees) Agilent E5071C Network Analyzer 9 khz to 4.5/6.5/8.5 GHz 100 khz to 4.5/6.5/8.5 GHz (with bias tees) 300 khz to 14/20 GHz (with bias tees) E5092A Configurable Multiport Test Set Configuration Guide This

More information

Installation Job Aid for VSP 4850GTS

Installation Job Aid for VSP 4850GTS Installation Job Aid for VSP 4850GTS Notices Release 6.1.0.0 NN46251-308 Issue 02.01 November 2017 Notice paragraphs alert you about issues that require your attention. The following paragraphs describe

More information

Agilent Technologies U3020AY03

Agilent Technologies U3020AY03 Agilent Technologies U3020AY03 User s Guide Use this manual with the following documents: U3020AY04 User s Guide (U3020-90009) PNA Series Network Analyzer On-line Help System Manufacturing Part Number:

More information

User Manual LKS-CD17SR 17 LCD Single Rail Console Drawer with Modular KVM Switch

User Manual  LKS-CD17SR 17 LCD Single Rail Console Drawer with Modular KVM Switch User Manual LKS-CD17SR 17 LCD Single Rail Console Drawer with Modular KVM Switch LKS-CD19SR 19 LCD Single Rail Console Drawer with Modular KVM Switch Rev 2.0 Packing List ServerLink LKS-CD17SR / CD19SR

More information

Installation Job Aid for VSP 4450GTX-HT- PWR+

Installation Job Aid for VSP 4450GTX-HT- PWR+ Installation Job Aid for VSP 4450GTX-HT- PWR+ Notices Release 6.1.0.0 NN46251-305 Issue 02.01 November 2017 Notice paragraphs alert you about issues that require your attention. The following paragraphs

More information

Compact Redundancy Switch 2:1 RSCC-2

Compact Redundancy Switch 2:1 RSCC-2 Compact Redundancy Switch 2:1 RSCC-2 The WORK Microwave Redundancy Switch RSCC-2 is compact solution for a 2:1 Redundancy System. It can be used for upconverters, downconverters, modulators and modulator-upconverters.

More information

Installation Job Aid for Ethernet Routing Switch 3600 Series

Installation Job Aid for Ethernet Routing Switch 3600 Series Installation Job Aid for Ethernet Routing Switch 3600 Series Notices NN47213-303 Issue 03.01 November 2017 Notice paragraphs alert you about issues that require your attention. Following are descriptions

More information

Installing the IPS 4345 and IPS 4360

Installing the IPS 4345 and IPS 4360 CHAPTER 4 Installing the IPS 4345 and IPS 4360 Contents This chapter describes the Cisco IPS 4345 and the IPS 4360, and includes the following sections: Installation Notes and Caveats, page 4-1 Product

More information

HP 8714B Calibration

HP 8714B Calibration Wireless Circuits and Systems Laboratory Procedure #7 Calibrating the HP 8714 Network Analyzer This procedure describes the different types of calibrations that are available with the HP 8714 vector network

More information

MONITORING INTELLIRACK USER MANUAL

MONITORING INTELLIRACK USER MANUAL MONITORING INTELLIRACK USER MANUAL TABLE OF CONTENTS 1.0 INTRODUCTION..........................................................1 1.1 Overview...................................................................

More information

RFS Ferrocom Isolators/Circulators

RFS Ferrocom Isolators/Circulators RFS Ferrocom Isolators/Circulators A broad range of ferrite devices which are unequaled in performance, quality and reliability. Coaxial Isodapters Drop-in Waveguide Ferrocom Ferrite Division TABLE OF

More information

The power behind competitiveness. Delta Infrasuite Power Management. Power Distribution Unit. User Manual.

The power behind competitiveness. Delta Infrasuite Power Management. Power Distribution Unit. User Manual. The power behind competitiveness Delta Infrasuite Power Management Power Distribution Unit User Manual www.deltapowersolutions.com Save This Manual This manual contains important instructions and warnings

More information

Infiniium Q- Series Oscilloscopes

Infiniium Q- Series Oscilloscopes Service Guide Publication Number 54932-97006 October 2013 Agilent Technologies, Inc. 2012-2013 Infiniium 90000 Q- Series Oscilloscopes The Agilent Technologies Infiniium 90000 Oscilloscope at a Glance

More information

Application Note FOR SMA Calibration Kit for VNA. LCAL06A A female calibration kit and used for DC ~ 6.0 GHz VNA test cable with male end connector.

Application Note FOR SMA Calibration Kit for VNA. LCAL06A A female calibration kit and used for DC ~ 6.0 GHz VNA test cable with male end connector. Application Note FOR SMA Calibration Kit for VNA LCAL06A, LCAL06B, LCAL06C and LCAL09A are precision SMA calibration kits which provide accurate and reliable Short-Open-Load-Thru (SOLT) or Load-Reflect-Match

More information

RF switch network. RFB 2000, RFC 2010 or 2020

RF switch network. RFB 2000, RFC 2010 or 2020 RFB 000, RFC 010 or 00 The can be configured to switch RF signals in a wide range of automatic test systems. Various switch configurations are available, connecting one input to either two or six outputs.

More information

14.5U 4X SDR/DDR InfiniBand Switch Platform User s Manual. Rev 0.10

14.5U 4X SDR/DDR InfiniBand Switch Platform User s Manual. Rev 0.10 14.5U 4X SDR/DDR InfiniBand Switch Platform User s Manual 2 Copyright 2007. International and its licensors. All rights reserved. 14.5U 4X SDR/DDR InfiniBand Switch Platform User s Manual 3 Contents Contents

More information

Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual

Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual Omnitron Systems Technology, Inc. 1 iconverter 19-Module Managed Power Chassis User s Manual 27 Mauchly, #201, Irvine, CA 92618 Phone: (949) 250-6510; Fax: (949) 250-6514 2 Omnitron Systems Technology,

More information

TRC-190 User s Manual

TRC-190 User s Manual User s Manual Edition 3.2, May 2017 www.moxa.com/product 2017 Moxa Inc. All rights reserved. User s Manual The software described in this manual is furnished under a license agreement and may be used only

More information

M250 (M LL) Safety

M250 (M LL) Safety M250 SAFETY M250 (M250-60-2LL) Safety Important Safety Information This document contains important instructions to use during installation of the Enphase M250 Microinverter. To reduce the risk of electrical

More information

Agilent 84904, 6, 7K/L Programmable Step Attenuators

Agilent 84904, 6, 7K/L Programmable Step Attenuators Agilent 84904, 6, 7K/L Programmable Step Attenuators Data Sheet High Accuracy,Excellent Reliability, Long Life Features and description DC to 26.5 GHz, DC to 40 GHz frequency coverage Optional calibration

More information

System Storage EXP3000 Rack Installation Instructions

System Storage EXP3000 Rack Installation Instructions System Storage EXP3000 Rack Installation Instructions Review the documentation that comes with your rack cabinet for safety and cabling information. When you install the IBM System Storage EXP3000 in a

More information

M215 (M215-60) Safety

M215 (M215-60) Safety M215 QUICK INSTALL GUIDE M215 (M215-60) Safety Important Safety Information This document contains important instructions to use during installation and maintenance of the Enphase M215 Microinverter. To

More information

PicoVNA. USB vector network analyzer. Quick Start Guide

PicoVNA. USB vector network analyzer. Quick Start Guide PicoVNA USB vector network analyzer Quick Start Guide CONTENTS 1. Introduction... 1 2. Safety information... 1 2.1 Symbols... 2 2.2 Maximum input and output ranges... 2 2.3 Grounding... 3 2.4 External

More information

Keysight Technologies E5071C Network Analyzer

Keysight Technologies E5071C Network Analyzer Keysight Technologies E5071C Network Analyzer 9 khz to 4.5/6.5/8.5 GHz 100 khz to 4.5/6.5/8.5 GHz (with bias tees) 300 khz to 14/20 GHz (with bias tees) E5092A Configurable Multiport Test Set Configuration

More information

High Voltage Power Supplies

High Voltage Power Supplies Source voltages up to 5kV and 10kV 1µA current measurement resolution Multi-channel programmable DC power supplies Low noise for precision sourcing and sensitive measurements; selectable filters reduce

More information

Replacing the Power Supply

Replacing the Power Supply APPENDIX B This appendix includes information on how to replace the power supply for the Cisco AS550XM universal gateway and contains the following sections: Safety Recommendations, page B-1 Required Tools

More information

Keysight MOI for USB Type-C Cable Assemblies Compliance Tests Using Keysight M937XA Multiport PXIe VNA

Keysight MOI for USB Type-C Cable Assemblies Compliance Tests Using Keysight M937XA Multiport PXIe VNA Revision 1.01 Feb-24, 2017 Universal Serial Bus Type-C TM Specification Revision 1.1 Keysight Method of Implementation (MOI) for USB Type-C TM Cables Assemblies Compliance Tests Using Keysight For Type-C

More information

120Ra-1 Pentium III Processor Installation Insert

120Ra-1 Pentium III Processor Installation Insert 120Ra-1 Pentium III Processor Installation Insert PN: 455-01614-000 Proprietary Notice and Liability Disclaimer The information disclosed in this document, including all designs and related materials,

More information

Keysight 11636B APC-3.5 mm Power Divider DC to 26.5 GHz

Keysight 11636B APC-3.5 mm Power Divider DC to 26.5 GHz Keysight 11636B APC-3.5 mm Power Divider DC to 26.5 GHz Operating and Service Manual Notices Keysight Technologies 1985, 2013, 2014 No part of this manual may be reproduced in any form or by any means

More information

Advanced Test Equipment Rentals ATEC (2832)

Advanced Test Equipment Rentals ATEC (2832) Established 1981 Advanced Test Equipment Rentals www.atecorp.com 800-404-ATEC (2832) OPERATION AND MAINTENANCE MANUAL FOR SWR AUTOTESTERS AND BRIDGES 1. INTRODUCTION This manual provides product descriptions

More information

EDGES Receiver Calibration Steps Tom Mozdzen

EDGES Receiver Calibration Steps Tom Mozdzen EDGES Receiver Calibration Steps Tom Mozdzen January 23, 2018 This document provides a description of the steps required to calibrate an EDGES receiver. Detailed pictures and instrument settings as well

More information

Application Note. Use of Palm Switches with QuadTech Hipot Testers

Application Note. Use of Palm Switches with QuadTech Hipot Testers Application Note Use of Palm Switches with QuadTech Hipot Testers Operator safety is an important aspect to consider when dealing with high voltage devices and instruments such as hipot testers. To improve

More information

Installation Note. Removable Hard Disk Drive Upgrade Kit. For All PNA Series RF Network Analyzers. Network Analyzer Model Number

Installation Note. Removable Hard Disk Drive Upgrade Kit. For All PNA Series RF Network Analyzers. Network Analyzer Model Number Installation Note Removable Hard Disk Drive Upgrade Kit For All PNA Series RF Network Analyzers Network Analyzer Model Number E8356A, E8357A, E8358A E8801A, E8802A, E8803A N3381A, N3382A, N3383A Upgrade

More information

TABLE OF CONTENTS 1. OVERVIEW... 1

TABLE OF CONTENTS 1. OVERVIEW... 1 TABLE OF CONTENTS 1. OVERVIEW... 1 1.1. SPECIFICATIONS... 1 1.1.1. Electrical... 1 1.1.2. Compliance... 2 1.1.3. Physical... 2 1.2. COOLING... 2 1.2.1. Fan Exhaust... 2 1.3. MOUNTING... 3 1.4. POWER...

More information

Racal Instruments 1257A. Scalable RF Interface Unit. Product Information. The Racal Instruments 1257A is a Commercial-Off-The

Racal Instruments 1257A. Scalable RF Interface Unit. Product Information. The Racal Instruments 1257A is a Commercial-Off-The Racal Instruments 1257A Scalable RF Interface Unit The is a sixth-generation RFIU design with four Commercial Off-The-Shelf (COTS) options from 1U to 4U. It comes with a new easy-to-use LXI Core 2011-compliant

More information

Service Manual. P GHz Active Probe

Service Manual. P GHz Active Probe Service Manual P7240 4 GHz Active Probe 071-1056-00 Warning The servicing instructions are for use by qualified personnel only. To avoid personal injury, do not perform any servicing unless you are qualified

More information

DANTE BRIDGE. Operation Manual

DANTE BRIDGE. Operation Manual DANTE BRIDGE Operation Manual Important Safety Instructions Important safety instructions Please carefully read following instructions and safety information and retain for future reference. Heed all warnings

More information

MODULUS 21 Power Distribution Unit (PDU) Replacement. Overview A. Introduction

MODULUS 21 Power Distribution Unit (PDU) Replacement. Overview A. Introduction Page 1 of 16 MODULUS 21 Power Distribution Unit (PDU) Replacement Overview Introduction This notice explains how to replace the AC Power Distribution Unit (PDU), also known as a Power Distribution Assembly

More information

Warning - Read the entire VDI User guide for this product prior to operation.

Warning - Read the entire VDI User guide for this product prior to operation. VDI USER GUIDE Product: 1900 GHz Amplifier Multiplier Chain Serial Number(s): VDI-AMC-S186B (upgrade) Amplifier: Spacek Labs A286-2XWB-33 SN 8M18 Components: VDI 52R1X2 1-17, VDI 110R1X2 1-14, VDI 200R2X2

More information

Adapter 2.92 mm-f to 2.92 mm-m

Adapter 2.92 mm-f to 2.92 mm-m Coaxial Adapter 2.92 mm-f to 2.92 mm-m 50Ω DC to 40 GHz The Big Deal Ultra-wideband, DC-40 GHz Flat response Low insertion loss, 0.09 db Excellent, 1.04:1 CASE STYLE: DJ1861 Product Overview Mini-Circuits

More information

Keysight Combiner and Mechanical Switches Upgrade Kit

Keysight Combiner and Mechanical Switches Upgrade Kit Keysight Combiner and Mechanical Switches Upgrade Kit To Upgrade PNA-X N5247A/B Option 419 to Option 423 Upgrade Kit Order Number: N5247AU-927 and N5247BU-423 Keysight Kit Number: N5247-60104 Installation

More information

Dell MD1280 Storage Enclosure Getting Started Guide

Dell MD1280 Storage Enclosure Getting Started Guide Dell MD1280 Storage Enclosure Getting Started Guide Regulatory Model: SP-2584, E11J Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your computer.

More information

MPI TS150-AIT 150 mm Manual Probe System

MPI TS150-AIT 150 mm Manual Probe System MPI TS150-AIT 150 mm Manual Probe System Industry s first explicitly designed 150 mm probe system providing accurate tests for mm-wave, THz, and automated impedance tuner applications FEATURES / BENEFITS

More information

Model 2380 Rack-Mount Kit

Model 2380 Rack-Mount Kit Keithley Instruments 28775 Aurora Road Cleveland, Ohio 44139 1-800-935-5595 http://www.tek.com/keithley Model 2380 Rack-Mount Kit Installation Instructions Introduction The Model 2380 Fixed Rack-Mount

More information

200 VA bis VA 10 V bis 80 V 2 A bis 320 A. Source-Sink NL

200 VA bis VA 10 V bis 80 V 2 A bis 320 A. Source-Sink NL 200 VA bis 3.120 VA 10 V bis 80 V 2 A bis 320 A NL AC, NL Series Interface overview RS-232 X USB X GPIB O LAN O System bus O Analog X Analog isolated O X Standard O Option / not available NL1V20C40 2-quadrant

More information