VectorStar ME7838A4 Multiport Broadband/Banded Millimeter-Wave System
|
|
- Dennis Merritt
- 5 years ago
- Views:
Transcription
1 Quick Start Guide VectorStar ME7A4 Multiport Broadband/Banded Millimeter-Wave System High Performance Modular Broadband/Banded Millimeter-Wave Vector Network Analyzer (VNA) Multiport Measurement System ME7A4, 70 khz to 0 () GHz Anritsu Company 490 Jarvis Drive Morgan Hill, CA USA Part Number: Revision: A Published: March 0 Copyright 0 Anritsu Company
2 . ME7A4 Main Components High Performance Modular Broadband/Banded Millimeter-Wave Vector Network Analyzer (VNA) Measurement System, 70 khz to GHz This guide provides quick setup instructions for the ME7A4 Multiport Broadband/Banded mm-wave VNA System assembly. For additional safety and compliance information, and for more details about the assembly, configuration, setup, and initial testing of the equipment, refer to the VectorStar ME7A4 Series Multiport Broadband Vector Network Analyzers Installation Guide This and all other documentation that supports the ME7A4 is available on the VectorStar User Documentation Disc Calibration, Verification, and System Performance Verification documents are included on a separate disc included with each calibration/verification kit.. ME7A4 Main Components ME7A4 Broadband Systems The ME7A4 Multiport Broadband system consists of the following components: MS447A or MS447B VNA with Option 007 (Receiver Offset) and Option 0x (Modular Broadband Connection Capability) MN497C Multiport Test Set 7B Broadband Test Set 79C Broadband Test Set Four 74A Millimeter-Wave Modules Front and rear panel cables ME7A4 Banded Systems The ME7A4 Multiport Banded system consists of the following components: MS44xA/B VNA with Option 0x MN494C Multiport Test Set 7B Broadband Test Set 79C Broadband Test Set Four 744A-EE, 744A-EW, or four OML/VDI Millimeter-Wave Modules Front and rear panel cables Caution A MS44xA/B VNA unit is heavy. To avoid personal injury, it must be lifted and maneuvered by at least two people during installation. If mounting on a workbench surface, first position the 79C Broadband Test Set with access to its front and rear panels. Stack the remaining test sets on top of one another, then finally the VNA. If mounting into rack or console, make sure the Test Sets have been installed, and that the rack/console is carefully positioned on a flat and level surface. If equipped, make sure any casters are locked. Use two people to lift the VNA unit and two to guide it into its shelf rails. The test loops on the front and rear panels of the VNA are delicate. Be careful not to bump or bend the test loops. QSG- PN: Rev. A VectorStar ME7A4 QSG
3 . Rear Panel Connections Between System Components (MS44xA VNA). Rear Panel Connections Between System Components (MS44xA VNA) In this section, connect the cables between the VNA and the Test Sets as shown in Figure and Table MS44xA VNA MN49xC Test Set B Test Set 4 Ext Alc Out Ext Analog In IF Outputs a b a b External I/O Module Interface Cable Length WARNING No operator serviceable parts inside. Refer servicing to qualified personnel. CAUTION Do not operate with power cord ungrounded. ~ LINE INPUT 47- Hz -40 VAC 0 VA Max Fuse 0V A T CAUTION 79C Test Set Standard Extended For continued fire protection replace only with specified type and rated fuse. Figure ME7A4 Rear Panel Cable Connections (MS44xA VNA) VectorStar ME7A4 QSG PN: Rev. A QSG-
4 . Rear Panel Connections Between System Components (MS44xA VNA) Table. ME7A4 Multiport Rear Panel Cable Connections ( of ) Index Part Number Cable Description Connection From Connection To -0- BNC (male-male), 4 in -0- BNC (male-male), 4 in -0- BNC (male-male), 4 in 4-0- BNC (male-male), 4 in a ( cable bundle) -074 a ( cable bundle) DB- DB GPIB, m SMA male-male flexible: SMA male-male flexible: a SMA male-male -0 a SMA male-male - a SMA male-male 4-0 a SMA male-male - a SMA male-male -0 a SMA male-male 7 - a SMA male-male MS44xA port Ext Analog Out MS44xA port Ext ALC 7B port (To Test Set) EXT ANALOG OUT 7B port (To Test Set) EXT ALC IN 7B port TO TEST SET EXTERNAL I/O 7B ports (IF INPUTS) a b a b MS44xA ports (Inputs/Outputs) a IF b IF a IF b IF MS44xA port External I/O MS44xA port Dedicated GPIB MS44xA port b loop out MS44xA port b loop in MS44xA port P source loop out MS44xA port P source loop in MS44xA port b loop out MS44xA port b loop in MS44xA port P source loop out 7B port EXT ANALOG IN 7B port EXT ALC OUT 79C port EXT ANALOG IN 79C port EXT ALC OUT 79C port EXTERNAL I/O 79C ports (IF OUTPUTS) a b a b 7B ports (IF OUTPUTS) a IF b IF a IF b IF 7B port TO VNA EXTERNAL I/O MN49xC port IEEE 4. GPIB MN49xC port TO VNA b OUTPUT MN49xC port TO VNA b INPUT MN49xC port TO VNA Port Src OUTPUT MN49xC port TO VNA Port Src INPUT MN49xC port TO VNA b OUTPUT MN49xC port TO VNA b INPUT MN49xC port TO VNA Port Src OUTPUT QSG-4 PN: Rev. A VectorStar ME7A4 QSG
5 . Rear Panel Connections Between System Components (MS44xA VNA) Table. ME7A4 Multiport Rear Panel Cable Connections ( of ) Index Part Number Cable Description Connection From Connection To -0 a SMA male-male 9 MS44xA VNA 0 MN49xC Test Set 7B Test Set 79C Test Set MS44xA port P source loop in a. Tighten each cable in this group using an mm (/ in) torque end wrench set to 0.9 N m ( lbf in). MN49xC port TO VNA Port Src INPUT VectorStar ME7A4 QSG PN: Rev. A QSG-
6 . Rear Panel Connections Between Components (MS44xB VNA). Rear Panel Connections Between Components (MS44xB VNA) In this section, connect the cables between the VNA and the Test Sets as shown in Figure or Figure, and Table. Cable Connections (Systems with Option 0 Dual Source Architecture) Ext In ALC and Ext In ALC (With Option 0) 9 MS44xB VNA MN49xC Test Set Ext ALC (With Option 0) B Test Set Ext ALC (With Option 0) 4 Ext Alc Out Ext Analog In IF Outputs a b a b External I/O Module Interface Cable Length Standard Extended WARNING No operator serviceable parts inside. Refer servicing to qualified personnel. CAUTION Do not operate with power cord ungrounded. ~ LINE INPUT 47- Hz -40 VAC 0 VA Max Fuse 0V A T CAUTION For continued fire protection replace only with specified type and rated fuse. 79C Test Set Figure ME7A4 Multiport BB/mmW VNA System Rear Panel Cables (With Option 0) QSG- PN: Rev. A VectorStar ME7A4 QSG
7 Cable Connections (Systems without Option 0). Rear Panel Connections Between Components (MS44xB VNA) MS44xB VNA MN49xC Test Set B Test Set 4 Ext Alc Out Ext Analog In IF Outputs a b a b External I/O Module Interface Cable Length WARNING No operator serviceable parts inside. Refer servicing to qualified personnel. CAUTION Do not operate with power cord ungrounded. ~ LINE INPUT 47- Hz -40 VAC 0 VA Max Fuse 0V A T CAUTION 79C Test Set Standard Extended For continued fire protection replace only with specified type and rated fuse. Figure ME7A4 Multiport BB/mmW VNA System Rear Panel Cables (No Option 0) VectorStar ME7A4 QSG PN: Rev. A QSG-7
8 . Rear Panel Connections Between Components (MS44xB VNA) Table. ME7A4 Multiport Rear Panel Cable Connections (MS44xB) ( of ) Index Part Number Cable Description Connection From Connection To -0- BNC (male-male), 4 in -0- BNC (male-male), 4 in -0- BNC (male-male), 4 in -0- BNC (male-male), 4 in -0- BNC (male-male), 4 in 4-0- BNC (male-male), 4 in a ( cable bundle) -074 a ( cable bundle) DB- DB GPIB, m SMA male-male flexible: SMA male-male flexible: a SMA male-male -0 a SMA male-male - a SMA male-male MS44xB port Ext Analog Out Ext In ALC (No Option 0) (Figure ) Ext In ALC (With Option 0) (Figure ) Ext In ALC (With Option 0) (Figure ) 7B port (To Test Set) EXT ANALOG OUT 7B port (To Test Set) EXT ALC IN (Figure ) (Not used with Option 0) 7B port TO TEST SET EXTERNAL I/O 7B ports (IF INPUTS) a b a b MS44xB ports (Inputs/Outputs) a IF b IF a IF b IF MS44xB port External I/O MS44xB port Dedicated GPIB MS44xB port b loop out MS44xB port b loop in MS44xB port P source loop out 7B port EXT ANALOG IN 7B port EXT ALC OUT 79C port EXT ALC OUT 7B port EXT ALC OUT 79C port EXT ANALOG IN 79C port EXT ALC OUT 79C port EXTERNAL I/O 79C ports (IF OUTPUTS) a b a b 7B ports (IF OUTPUTS) a IF b IF a IF b IF 7B port TO VNA EXTERNAL I/O MN49xC port IEEE 4. GPIB MN49xC port TO VNA b OUTPUT MN49xC port TO VNA b INPUT MN49xC port TO VNA Port Src OUTPUT QSG- PN: Rev. A VectorStar ME7A4 QSG
9 . Rear Panel Connections Between Components (MS44xB VNA) Table. ME7A4 Multiport Rear Panel Cable Connections (MS44xB) ( of ) Index Part Number Cable Description Connection From Connection To 4-0 a SMA male-male - a SMA male-male -0 a SMA male-male 7 - a SMA male-male -0 a SMA male-male 9 MS44xB VNA 0 MN49xC Test Set 7B Test Set 79C Test Set MS44xB port P source loop in MS44xB port b loop out MS44xB port b loop in MS44xB port P source loop out MS44xB port P source loop in MN49xC port TO VNA Port Src INPUT MN49xC port TO VNA b OUTPUT MN49xC port TO VNA b INPUT a. Tighten each cable in this group using an mm (/ in) torque end wrench set to 0.9 N m ( lbf in). MN49xC port TO VNA Port Src OUTPUT MN49xC port TO VNA Port Src INPUT VectorStar ME7A4 QSG PN: Rev. A QSG-9
10 4. Semi-rigid Cable Connections Between System Components 4. Semi-rigid Cable Connections Between System Components Make the cable connections as shown in Figure 4 or Figure, and in Table. If your system has Option 0 Dual Source Architecture (MS44xB only), use Figure 4. If your system does not have Option 0, use Figure. Frequency Calibration Power Measurement Sweep Application Channel Avg System Response 7 Trace Display File Help Scale Marker Preset Standby Operate ALL PORTS: CAUTION +7 dbm MAX AVOID STATIC DISCHARGE 4 RF LO Out In In Out 9 Install Termination Removed from VNA RF or RF 0 Figure 4 ME7A4 Multiport Semi-rigid Cable Connections (with Option 0 Dual Source Architecture) QSG-0 PN: Rev. A VectorStar ME7A4 QSG
11 4. Semi-rigid Cable Connections Between System Components Frequency Calibration Power Measurement Sweep Application Channel Avg System Response File 7 Trace Display Scale Help Marker Preset Standby Operate ALL PORTS: CAUTION +7 dbm MAX AVOID STATIC DISCHARGE RF LO Out In In Out Figure ME7A4 Multiport Cable Connections (No Option 0) VectorStar ME7A4 QSG PN: Rev. A QSG-
12 4. Semi-rigid Cable Connections Between System Components Table. ME7A4 Multiport Cable Interconnect Part Numbers and Locations ( of ) Index Part Numbers Description/Torque Connection From Connection To V (m-m) (MN497C) -77- K (m-m) (MN494C) (With Option 0) 77- (No Option 0) 77-9 Front Panel RF Cable (4 each) V or K male-male Tighten using an mm (/ in) torque end wrench set to 0.9 N m ( lbf in). Front Panel RF Cable K male-male Tighten using an mm (/ in) torque end wrench set to 0.9 N m ( lbf in). Front Panel LO Cable ( each) K male-male Tighten using an mm (/ in) torque end wrench set to 0.9 N m ( lbf in). Front Panel RF Cable K male-male Tighten using an mm (/ in) torque end wrench set to 0.9 N m ( lbf in). Front Panel LO Cable ( each) K male-male Tighten using an mm (/ in) torque end wrench set to 0.9 N m ( lbf in). b (In) b (Out) Port Source (In) Port Source (Out) Port Source (In) Port Source (Out) b (In) b (Out) RF (Figure 4) (With Option 0) RF (Figure ) (No Option 0) LO LO RF (Figure 4) (With Option 0) 7B Test Set port RF Out (Figure ) (No Option 0) 7B Test Set port LO Out 7B Test Set port LO Out MN49xC port b (In) MN49xC port b (Out) MN49xC port Port Source (In) MN49xC port Port Source (Out) MN49xC port Port Source (In) MN49xC port Port Source (Out) MN49xC port b (In) MN49xC port b (Out) 7B Test Set port RF In 7B Test Set port RF In 7B Test Set port LO In 7B Test Set port LO In 79C Test Set port RF 79C Test Set port RF 79C Test Set port LO 79C Test Set port LO QSG- PN: Rev. A VectorStar ME7A4 QSG
13 4. Semi-rigid Cable Connections Between System Components Table. ME7A4 Multiport Cable Interconnect Part Numbers and Locations ( of ) Index Part Numbers Description/Torque Connection From Connection To V0 7 MS44xA VNA MS44xB VNA MS447A VNA MS447B VNA MN494C Test Set MN497C Test Set 9 7B Test Set 0 79C Test Set Termination (With Option 0) Tighten using an mm (/ in) torque end wrench set to 0.9 N m ( lbf in). Option 0, 0, or 0, and 0x (Banded) Option 0, 0, or 0, and 0x (Banded) Option 0, 0, or 0, and 0x (Broadband) Option 0, 0, or 0, and 0x (Broadband) (Banded) (Broadband) Remove from VNA port RF or RF (With Option 0) Add to 7B Test Set port RF Out VectorStar ME7A4 QSG PN: Rev. A QSG-
14 . Front Panel Cable Connections. Front Panel Cable Connections Make the cable connections as shown in Figure and in Table 4. 9 ALL PORTS: CAUTION +7 dbm MAX AVOID STATIC DISCHARGE 0 4 RF LO Out In Port 7 In Out Port 4 Port Port Port Module Port Module Test Port to Module SRC (74A only) Test Port to Module SRC (74A only) Port Module 7 Port 4 Module Test Port to Module SRC (74A only) 4 Test Port 4 to Module SRC (74A only) Figure Front Panel to mm-wave Module Connections QSG-4 PN: Rev. A VectorStar ME7A4 QSG
15 . Front Panel Cable Connections Note The cables for Test Port through Test Port 4 to Module SRC are not used with mm-wave modules 744A-EE, 744A-EW, or 744A-Rx. Table 4. ME7A4 Cable Interconnect Part Numbers and Locations ( of ) Index Part Number Description Connection From Connection To a,b Coaxial Phase Stable Cable (4 each) V male-female flexible, in Used with 74A Broadband Modules only Tighten at Test Set using an mm (/ in) torque end wrench set to 0.9 N m ( lbf in). MN49xC port Port Port Port Port 4 74A port (Port Module) SRC (Port Module) SRC (Port Module) SRC (Port 4 Module) SRC 7 7- a mm-wave Module Interface Cables (for 74A, 744A-EE, 744A-EW modules) Group of cables for each port Tighten at Test Set using an mm (/ in) torque end wrench set to 0.9 N m ( lbf in). 79C Test Set: Port, Port RF, LO, Test, Ref, Power/Signal 7B Test Set Port, Port (Port, Port 4) RF, LO, Test, Ref, Power/Signal mm-wave Modules: Port, Port Modules RF, LO, Test, Ref, Power/Signal mm-wave Modules Port, Port 4 Modules RF, LO, Test, Ref, Power/Signal OML Module Interface Cables Group of 4 cables for each port 79C Test Set Port, Port RF, LO, Test, Ref OML Modules Port, Port Modules RF, LO, Test IF, Ref IF 7 7- a Tighten at Test Set using an mm (/ in) torque end wrench set to 0.9 N m ( lbf in). VDI Module Interface Cables Group of 4 cables for each port Tighten at Test Set using an mm (/ in) torque end wrench set to 0.9 N m ( lbf in). 7B Test Set Port, Port (Port, Port 4) RF, LO, Test, Ref 79C Test Set Port, Port RF, LO, Test, Ref 7B Test Set Port, Port (Port, Port 4) RF, LO, Test, Ref OML Modules Port, Port 4 Modules RF, LO, Test IF, Ref IF VDI Modules Port, Port Modules RF Input, LO Input, Meas. IF, Ref IF VDI Modules Port, Port 4 Modules RF Input, LO Input, Meas. IF, Ref IF 7 7- a mm-wave Module Interface Cables (for 744A-Rx modules) Group of cables for each port Tighten at Test Set using an mm (/ in) torque end wrench set to 0.9 N m ( lbf in). 79C Test Set Port, Port LO, Test, Power/Signal 7B Test Set Port, Port (Port, Port 4) LO, Test, Power/Signal Rx Modules Port, Port Modules LO, Test, Power/Signal Rx Modules Port, Port 4 Modules LO, Test, Power/Signal VectorStar ME7A4 QSG PN: Rev. A QSG-
16 . Front Panel Cable Connections Table 4. ME7A4 Cable Interconnect Part Numbers and Locations ( of ) Index Part Number Description Connection From Connection To 9 MS44xA VNA - Option 0, 0, or 0, and 0x (Banded) MS44xB VNA - Option 0, 0, or 0, and 0x (Banded) MS447A VNA - Option 0, 0, or 0, and 0x (Broadband) MS447B VNA - Option 0, 0, or 0, and 0x (Broadband) 0 MN494C Test Set (Banded) MN497C Test Set (Broadband) 7B Test Set 79C Test Set a. Do not yet connect the cable ends to the Millimeter-Wave modules. Module connection instructions follow this section. b. Cable 0-09 Coaxial Phase Stable Cable is not included or required when using the 744A-EE, 744A-EW mm-wave modules, or the 744A-Rx Receiver Module. QSG- PN: Rev. A VectorStar ME7A4 QSG
17 . Front Panel to Millimeter-Wave Module Connections. Front Panel to Millimeter-Wave Module Connections Connect the 7B and 79C Broadband Test Set test port cables to the 74A, 744A-EE, 744A-EW, or 744A-Rx Modules as shown below, observing the correct torque limits for each connector. See Figure 7 and Table. Route the cable assemblies through the module cable restraint. Note It is easier to first connect the cables to the module and then mount the module in its bracket. Observe torque instructions where indicated. Each module (except the 744A-Rx) is characterized for a specific VNA Serial Number and VNA Test Port as designated on the module port assignment label. Ensure the module matches the correct VNA and Test Set port. For more detailed information on the modules including DUT Waveguide (WG) connection alignment and custom bracket mounting, refer to VectorStar Broadband/Banded Millimeter-Wave Modules Reference Manual. Inverting a Module If necessary, a module can be turned over in the bracket to change the elevation of the W connector. To turn the module over:. Remove the six knurled head thumbscrews from the module.. Turn the module over.. Install the six thumbscrews. TEST 4 REF Power/Signal LO 7 9 RF SRC 74A LO SRC (Not used) RF 74A 0 TEST TEST REF (Not used) Power/Signal Power/Signal REF 744A-EE, 744A-EW LO 744A-Rx (Not used) RF SRC (Not used) Figure 7 Millimeter-Wave Module Connections VectorStar ME7A4 QSG PN: Rev. A QSG-7
18 . Front Panel to Millimeter-Wave Module Connections Table. Millimeter-Wave Module Connections Index Cable P/N Description N/A Millimeter-Wave Module in bracket N/A W - mm Connector (74A, 744A-Rx modules) Tighten using a torque end wrench and a plain end wrench mm Torque End Wrench set to 0.4 N m (4 lbf in). Recommended is Anritsu mm / 7 mm Open End Wrench. Recommended is Anritsu 0-0. WR-0 or WR- Adapter - mm connector (744A-EE, 744A-EW modules) Use Waveguide Adapter Toolkits (7494-, 7494-, or ). Tighten using a torque end wrench and a plain end wrench. mm Torque End Wrench set to 0.4 N m (4 lbf in). Recommended is Anritsu mm / 7 mm Open End Wrench. Recommended is Anritsu 0-0. TEST - SSMC Connector (74A, 744A-EE, 744A-EW, and 744A-Rx modules) Tighten using a 4 mm (/ in) torque end wrench set to less than 0. N m ( lbf in). Recommended is Anritsu 0- torque wrench. 7- a REF - SSMC Connector (74A, 744A-EE, and 744A-EW modules) 4 Tighten using a 4 mm (/ in) torque end wrench set to less than 0. N m ( lbf in). or Recommended is Anritsu 0- torque wrench. 7- b,c Power/Signal Bi-Lobe Connector (74A, 744A-EE, 744A-EW, 744A-Rx) LO - K Connector (74A, 744A-EE, 744A-EW, and 744A-Rx modules) Tighten using an mm (/ in) torque end wrench set to 0.9 N m ( lbf in). Recommended is Anritsu Module Power and I/O Cable Restraint 0-09 d Tighten using an mm (/ in) torque end wrench set to 0.9 N m ( lbf in). SRC - V Connector (74A module only) Recommended is Anritsu a Tighten using an mm (/ in) torque end wrench set to 0.9 N m ( lbf in). RF - V Connector (74A, 744A-EE, and 744A-EW modules) Recommended is Anritsu N/A Factory Calibrated Port Assignment Label N/A Module Serial Number Label a. 74A, 744A-EE, and 744A-EW modules use cable assembly 7-. b. The REF cable is not used in the 7- cable assembly. c. 744A-Rx module uses cable assembly 7-. d. Cable 0-09 Coaxial Phase Stable Cable is used only with the 74A modules. Millimeter-Wave Module Operating Environment The following notes should be observed when operating the 74A and 744A-xx mm-wave Modules: Thermal heat sinking similar to the supplied mounting brackets of the Millimeter-Wave Module should be considered in custom mounting applications. Each 74A Module consumes a maximum of watts. Each 744A-EE and 744A-EW Module consumes a maximum of watts. Each 744A-Rx Module consumes a maximum of 7 watts. The primary heat sink paths for the module is the two side mounting surfaces of the mounting bracket. With the attached cable mounting brackets, the case temperature rise is approximately C to 0 C above ambient. A three () Year warranty is valid for all versions of 744A and 74A modules, with or without mounting brackets attached. QSG- PN: Rev. A VectorStar ME7A4 QSG
19 7. Front Panel to OML/VDI Module Connections 7. Front Panel to OML/VDI Module Connections Connect the front panel cables between the 7B and 79C Test Sets, and the OML or VDI frequency extension modules as shown in Figure, Figure 9, and Figure 0, and as described in Table, Table 7, and Table. Caution To avoid connector damage, observe torque requirements where indicated. ALL PORTS: CAUTION +7 dbm MAX AVOID STATIC DISCHARGE RF LO Out In In Out Port Port 4 7 Port Port Port Module Port Module Port RF, LO, Test, Ref to OML/VDI Module Port RF, LO, Test, Ref to OML/VDI Module Port Module 4 Port 4 Module Port RF, LO, Test, Ref to OML/VDI Module Port 4 RF, LO, Test, Ref to OML/VDI Module Figure Cable Connections between 7B, 79C Test Sets, and OML or VDI Frequency Extension Modules VectorStar ME7A4 QSG PN: Rev. A QSG-9
20 7. Front Panel to OML/VDI Module Connections Table. ME7A4 OML/VDI Cable Interconnect Part Numbers and Locations Index Part Number Description Connection From Connection To 4 7- ( each) 7- ( each) MN49xC Test Set 7B Test Set 7 79C Test Set OML Module Interface Cable Assembly Group of 4 cables for each port OML Module Interface Cable Assembly Group of 4 cables for each port VDI Module Interface Cables Assembly Group of 4 cables for each port VDI Module Interface Cables Assembly Group of 4 cables for each port 79C Test Set Port, Port Ref RF LO Test 7B Test Set Port, Port (Port, Port 4) Ref RF LO Test 79C Test Set Port, Port RF Ref Test LO 7B Test Set Port, Port (Port, Port 4) RF Ref Test LO OML Modules: Port, Port Modules Ref IF RF Input LO Input Test IF OML Modules: Port, Port 4 Modules Ref IF RF Input LO Input Test IF VDI Modules: Port, Port Modules RF Input Ref. IF Meas. IF LO Input VDI Modules: Port, Port 4 Modules RF Input Ref. IF Meas. IF LO Input QSG-0 PN: Rev. A VectorStar ME7A4 QSG
21 7. Front Panel to OML/VDI Module Connections From ME7-79C Test Set Port, Port From ME7-7B Test Set Port, Port 4 Ref RF 4 LO Test OML Frequency Extension Modules (Typical) Ref RF LO Test Ref IF RF Input DC Power LO Input Test IF Ref IF RF Input DC Power LO Input Test IF OML Power Supply OML Power Supply Figure 9 VNA/ Test Set Cable Connections to OML Modules Table 7. OML Module Connections Index Cable P/N Description N/A OML Module 4 7- Ref IF - SMA Connector Tighten using an mm (/ in) torque end wrench set to 0.9 N m ( lbf in). Recommended is Anritsu 0-0. RF Input - SMA Connector Tighten using an mm (/ in) torque end wrench set to 0.9 N m ( lbf in). Recommended is Anritsu 0-0. LO Input - SMA Connector Tighten using an mm (/ in) torque end wrench set to 0.9 N m ( lbf in). Recommended is Anritsu 0-0. Test IF - SMA Connector Tighten using an mm (/ in) torque end wrench set to 0.9 N m ( lbf in). Recommended is Anritsu 0-0. N/A OML Module Power Supply Connector VectorStar ME7A4 QSG PN: Rev. A QSG-
22 7. Front Panel to OML/VDI Module Connections From ME7-79C Test Set Port, Port From ME7-7B Test Set Port, Port 4 RF Ref Test 4 LO VDI VNA Extender Modules (Typical) RF Ref Test LO RF Input Ref. IF Power Meas. IF LO Input RF Input Ref. IF Power Meas. IF LO Input VDI Power Supply VDI Power Supply Figure 0 VNA/ Test Set Cable Connections to VDI Modules Table. VDI Module Connections Index Cable P/N Description N/A VDI Module 4 a 7- RF Input - K (.9 mm) Connector Tighten using an mm (/ in) torque end wrench set to 0.9 N m ( lbf in). Recommended is Anritsu 0-0. Ref. IF - SMA Connector Tighten using an mm (/ in) torque end wrench set to 0.9 N m ( lbf in). Recommended is Anritsu 0-0. Meas. IF - SMA Connector Tighten using an mm (/ in) torque end wrench set to 0.9 N m ( lbf in). Recommended is Anritsu 0-0. LO Input- K (.9 mm) Connector Tighten using an mm (/ in) torque end wrench set to 0.9 N m ( lbf in). Recommended is Anritsu 0-0. VDI Module Power Supply Connector a.the VDI module connectors may differ slightly than on the illustration shown above. For example, depending on the model and date built, the power supply connector may be round instead of rectangular. QSG- PN: Rev. A VectorStar ME7A4 QSG
23
24 Anritsu utilizes recycled paper and environmentally conscious inks and toner. Anritsu Company 490 Jarvis Drive Morgan Hill, CA USA
VectorStar ME7838A Broadband/Banded Millimeter-Wave System
Established 1981 Advanced Test Equipment Rentals www.atecorp.com 800-404-ATEC (2832) Installation Guide VectorStar ME7838A Broadband/Banded Millimeter-Wave System High Performance Modular Broadband/Banded
More informationVectorStar Broadband/Banded Millimeter-Wave Modules
Reference Manual VectorStar Broadband/Banded Millimeter-Wave Modules MA253A Broadband Millimeter-Wave Module 3743A Broadband Millimeter-Wave Module 3743E Broadband Millimeter-Wave Module 3744A-EE Banded
More informationVectorStar ME7828A Series Broadband/Millimeter Wave System
Installation Guide VectorStar ME7828A Series Broadband/Millimeter Wave System High Performance Vector Network Analysis Measurement System from 10 MHz to 110 GHz Anritsu Company 490 Jarvis Drive Morgan
More informationR System Verification Software (SVS)
Quick Start Guide 2300-533-R System Verification Software (SVS) MS2026B and MS2028B VNA Master MS2026C, MS2027C, MS2028C, MS2036C, MS2037C, MS2038C VNA Master SC7858 Verification Kit, N Connectors SC7859
More informationDirect Connection of OML Frequency Extenders to Keysight s PNA-C (E836xC) VNA for 1-Path 2-Port S-Parameter Measurements
Direct Connection of OML Frequency Extenders to Keysight s PNA-C (E836xC) VNA for 1-Path 2-Port S-Parameter Measurements Introduction For full two-port S-parameter measurements to extend PNA-C vector network
More informationAgilent PNA Series Microwave Network Analyzers
Agilent PNA Series Microwave Network Analyzers Configuration Guide PNA-L N5230A PNA-L N5230A PNA E8362B PNA E8363B PNA E8364B PNA E8361A PNA N5250A 300 khz to 6, 13.5, or 20 GHz 10 MHz to 20, 40, or 50
More informationAgilent ENA-L RF Network Analyzers
Agilent ENA-L RF Network Analyzers Configuration Guide E5061A E5062A 300 khz to 1.5 GHz 300 khz to 3 GHz This configuration guide describes standard configurations, options, accessories and peripherals
More informationKeysight N9030A Signal Analyzer Option BBA Analog Baseband IQ Inputs Retrofit Kit
Keysight N9030A Signal Analyzer Option BBA Analog Baseband IQ Inputs Retrofit Kit Notice: This document contains references to Agilent. Please note that Agilent s Test and Measurement business has become
More informationAgilent PNA Series Microwave Network Analyzers
Agilent PNA Series Microwave Network Analyzers Configuration Guide PNA-L N5230A PNA-L N5230A PNA-X N5242A PNA E8362B PNA E8363B PNA E8364B PNA E8361A PNA N5250A 300 khz to 6, 13.5, or 20 GHz 10 MHz to
More informationInstallation Note. Agilent Technologies 85105A Option 50 Installation Instructions for RF Switch Replacement Kit
Installation Note Agilent Technologies 85105A Option 50 Installation Instructions for RF Switch Replacement Kit 85105-60047 Part Number 85105-90023 Printed in USA August 2002 Notice. The information contained
More informationKeysight Technologies PNA Series Microwave Network Analyzers
Keysight Technologies PNA Series Microwave Network Analyzers Configuration Guide PNA-L N5230A PNA-L N5230A PNA-X N5242A PNA E8362B PNA E8363B PNA E8364B PNA E8361A PNA N5250A 300 khz to 6, 13.5, or 20
More informationInstallation Note. IF Access Upgrade Kit. For PNA Series Microwave Network Analyzers. Network Analyzer Model Number. Upgrade Kit Part Number
Installation Note IF Access Upgrade Kit For PNA Series Microwave Network Analyzers Network Analyzer Model Number E8361A/C, E8362B/C, E8363B/C, E8364B/C Upgrade Kit Part Number E8362-60116 Agilent Part
More informationAgilent Upgrade Guide for the 8510 Vector Network Analyzer Product Note
Agilent Upgrade Guide for the 8510 Vector Network Analyzer Product Note Discontinued Product Information For Support Reference Only Information herein, may refer to products/services no longer supported.
More informationCisco CRS 3-Phase AC Power Distribution Unit Installation Guide 2. Cisco CRS 3-Phase AC Power Distribution Unit 2
Cisco CRS 3-Phase AC Power Distribution Unit Installation Guide Cisco CRS 3-Phase AC Power Distribution Unit Installation Guide 2 Cisco CRS 3-Phase AC Power Distribution Unit 2 Revised: November 18, 2016,
More informationKeysight Technologies Millimeter Wave Network Analyzers (N5290A/N5291A) Configuration Guide
Keysight Technologies Millimeter Wave Network Analyzers (N5290A/N5291A) Configuration Guide 02 Keysight Millimeter Wave Network Analyzers (N5290A/N5291A) - Cofiguration Guide Table of Contents Introduction...
More informationExtended Frequency Range Upgrade Kit (50 GHz to 67 GHz)
Installation Note Extended Frequency Range Upgrade Kit (50 GHz to 67 GHz) Upgrade Kit Number: E8364-60105 For E8364B/C Microwave Network Analyzers WITHOUT the Configurable Test Set Option (Option 014)
More informationAgilent 85130C NMD 3.5 mm to Type-N Adapter Kit
Agilent 85130C NMD 3.5 mm to Type-N Adapter Kit Operating and Service Manual Agilent Technologies Notices Agilent Technologies, Inc. 1987, 2004, 2008 No part of this manual may be reproduced in any form
More informationInstallation Note. Source Attenuators and Bias Tees Upgrade Kit. For E8362B/C PNA Series Microwave Network Analyzers. Network Analyzer Model Number
Installation Note Source Attenuators and Bias Tees Upgrade Kit For E8362B/C PNA Series Microwave Network Analyzers Network Analyzer Model Number Upgrade Kit Part Number E8362B/C E8362-60115 Agilent Part
More informationPXI Vector Network Analyzer
CONFIGURATION GUIDE PXI Vector Network Analyzer M9370A 300 khz to 4 GHz M9371A 300 khz to 6.5 GHz M9372A 300 khz to 9 GHz M9373A 300 khz to 14 GHz M9374A 300 khz to 20 GHz M9375A 300 khz to 26.5 GHz Drive
More informationSoftware User s Guide
Model 360X/372XXA Vector Network Analyzer Performance Verification Software Software User s Guide Software Revision 1.03 This manual applies to the WILTRON 360X/372XXA Vector Network Analyzer Performance
More informationKeysight 85130F NMD 2.4 mm to 3.5 mm Adapter Kit
Keysight 85130F NMD 2.4 mm to 3.5 mm Adapter Kit Operating and Service Manual Notices Keysight Technologies 1988-2015 No part of this manual may be reproduced in any form or by any means (including electronic
More informationLightning 37xxxE Series Vector Network Analyzer
Maintenance Manual Lightning 37xxxE Series Vector Network Analyzer Lightning 37247E VNA, K Connectors, 40.0 MHz to 20.0 GHz, Passive Measurements Lightning 37347E VNA, K Connectors, 40.0 MHz to 20.0 GHz,
More informationInstallation Note. Enhanced Memory Upgrade Kit (Option B72) for Agilent ESA-E Series and ESA-L Series Spectrum Analyzers
Installation Note Enhanced Memory Upgrade Kit (Option B72) for Agilent ESA-E Series and ESA-L Series Spectrum Analyzers Part Number E4401-90498 Supersedes: E4401-90332 Printed in USA July 2005 Notice.
More informationModel 4200-CVU-PWR. Parts Package. Introduction. PA-977 Rev. C / September 2016 *PPA-977C* 1
Keithley Instruments 28775 Aurora Road Cleveland, Ohio 44139 1-800-935-5595 http://www.tek.com/keithley Model 4200-CVU-PWR Parts Package Introduction The Model 4200-CVU-PWR C-V Power Package for both the
More informationKeysight 85130D NMD 3.5 mm to 3.5 mm Adapter Kit
Keysight 85130D NMD 3.5 mm to 3.5 mm Adapter Kit Operating and Service Manual Notices Keysight Technologies 1987-2015 No part of this manual may be reproduced in any form or by any means (including electronic
More informationAgilent RF Network Analyzers PNA Series
Agilent RF Network Analyzers PNA Series Configuration Guide E8356A E8357A E8358A 300 khz to 3 GHz 300 khz to 6 GHz 300 khz to 9 GHz System Configuration Summary This summary lists the main components required
More informationKeysight Second Source, Combiner, and Mechanical Switches Upgrade Kit
Keysight Second Source, Combiner, and Mechanical Switches Upgrade Kit To Upgrade PNA-X N5241A, N5242A, or N5249A Option 419 to Option 423 Upgrade Kit Order Number: N5241AU- 927, N5242AU- 927, and N5249AU-
More informationQuick Start. This document describes how to install the Juniper Networks PTX5000 Packet Transport
PTX5000 Packet Transport Router Quick Start September 2017 Part Number: 530-066788 Revision 01 This document describes how to install the Juniper Networks PTX5000 Packet Transport Router. Contents Quick
More informationATEC (2832) Models 8757A, 85027A/B/C, 85020A/B
Established 1981 Advanced Test NETWORK Equipment ANALYZERS Rentals 8757/8756 System Accessories wwwatecorpcom 800-404-ATEC (2832) Models 8757A, 85027A/B/C, 85020A/B UP]] HP 8757A Specifications Amplitude
More informationSeries 8900 LAN. Operation Manual. Part Number (example configuration) Part Number (example configuration)
Series 8900 LAN Part Number 90570300 (example configuration) Part Number 90570300-001 (example configuration) Operation Manual Operation Manual, Part Number 07508900-001, Rev. B, February 26, 2013 All
More informationNV1000 Terminal Equipment Operations Manual Introduction. Manual Part No. MI February, 1996
Nvision@ NV1000 Terminal Equipment Operations Manual Introduction CONTENTS 1. MANUAL DESCRIPTION 2. OVERVIEW 3. POWER AND THERMAL CONSIDERATIONS 4. INSTALLATION Manual Part No. MI1000-01 February, 1996
More informationModel 2657A-LIM-3 LO Interconnect Module
Keithley Instruments, Inc. 28775 Aurora Road Cleveland, Ohio 44139 1-888-KEITHLEY http://www.keithley.com Model 2657A-LIM-3 LO Interconnect Module User's Guide Description The Model 2657A-LIM-3 LO Interconnect
More informationKeysight Second Source, Combiner, and Mechanical Switches Upgrade Kit
Keysight Second Source, Combiner, and Mechanical Switches Upgrade Kit To Upgrade PNA-X N5241A or N5242A Option 219 to Option 224 For Analyzers with Serial Numbers Prefixed MY/SG/ US5201 and Above Upgrade
More informationKeysight Technologies N9020B MXA Signal Analyzer
Keysight Technologies N9020B MXA Signal Analyzer Analog Baseband IQ Inputs (Option BBA) Upgrade Kit Notice: This document contains references to Agilent. Please note that Agilent s Test and Measurement
More informationInstallation Note. Configurable Test Set Upgrade Kit. For PNA Series RF Network Analyzers (E8801A, E8802A, and E8803A) Network Analyzer Model Number
Installation Note Configurable Test Set Upgrade Kit For PNA Series RF Network Analyzers (E8801A, E8802A, and E8803A) Network Analyzer Model Number Upgrade Kit Part Number E8801A, E8802A, E8803A E8801-60103
More informationAgilent ENA RF Network Analyzer
Agilent ENA RF Network Analyzer Configuration Guide E5071C E5091A 9 khz to 4.5 GHz 100 khz to 4.5 GHz (with bias tees) 9 khz to 8.5 GHz 100 khz to 8.5 GHz (with bias tees) Multiport test set This configuration
More informationS-Band Redundant LNA Systems
S-Band Redundant LNA Systems LRS-1000 Series Introduction Redundant LNA systems minimize system downtime due to LNA failure by providing a spare LNA and an automatic means of switching to the spare upon
More informationRF Characterization Report
RF058 Series Cable Assemblies RF058-01BJ1-01BJ1-0150 RF058-01SB1-01SB1-0150 RF058-01SP1-01SP1-0150 Description: RF Cable Assembly, 50Ohm, RG058 Coaxial Cable Samtec Inc. WWW.SAMTEC.COM Phone: 812-944-6733
More informationModel GHz 50 Ohm RF Module
Keithley Instruments 28775 Aurora Road Cleveland, Ohio 44139 1-800-935-5595 tek.com/keithley Model 7711 2 GHz 50 Ohm RF Module Instructions for use with DAQ6510 Introduction The 7711 plug-in module provides
More informationKeithley Instruments Customer Documentation Series 2600A UL Safety Supplement
Keithley Instruments, Inc. 28775 Aurora Road Cleveland, Ohio 44139 1-888-KEITHLEY www.keithley.com Keithley Instruments Customer Documentation Series 2600A UL Safety Supplement 1. Introduction The Keithley
More informationKu-Band Solid-State Power Amplifier
PKM14S200R Ku-Band Solid-State Power Amplifier This high power solid-state amplifier offers an output power of 200 watts across the standard 14.0 to 14.5 GHz satellite uplink band. Built for reliable,
More informationLevelOne. KVM-0115/KVM / 17-inch LCD KVM Rack Console. User Manual. Version
LevelOne KVM-0115/KVM-0117 15 / 17-inch LCD KVM Rack Console User Manual Version 1.0-1305 1 SAFETY INSTRUCTIONS 1. Please read these safety instructions carefully. 2. Please keep this User Manual for later
More informationSERIES MS462XX VECTOR NETWORK MEASUREMENT SYSTEM VERIFICATION KITS OPERATION AND MAINTENANCE MANUAL
SERIES MS462XX VECTOR NETWORK MEASUREMENT SYSTEM VERIFICATION KITS OPERATION AND MAINTENANCE MANUAL 490 JARVIS DRIVE l MORGAN HILL, CA 95037-2809 P/N: 10100-00036 REVISION: A PRINTED: MAY 1999 COPYRIGHT
More informationAgilent. E5092A Configurable Multiport Test Set. Configuration Guide
Agilent E5071C Network Analyzer 9 khz to 4.5 GHz 100 khz to 4.5 GHz (with bias tees) 9 khz to 8.5 GHz 100 khz to 8.5 GHz (with bias tees) 300 khz to 20 GHz (with bias tees) E5092A Configurable Multiport
More information5 Performance Verification
5 Performance Verification Performance Verification TEST EQUIPMENT REQUIRED This procedure can be used to verify the warranted characteristics of the CP015 Current Probe. The recommended calibration interval
More informationInstruction Manual Model Block Translator
Instruction Manual Model 2083-1010 Block Translator May 2018, Rev. 0 1250>1200 G=-10.0 REF = AUTO - I MENU MODEL 2083 TRANSLATOR CROSS TECHNOLOGIES INC. REMOTE POWER ALARM EXECUTE Data, drawings, and other
More informationLASER PLUS OPERATING INSTRUCTIONS
LASER PLUS OPERATING INSTRUCTIONS Phone: (209) 586-1022 (800) 545-1022 Fax: (209) 586-1026 E-Mail: salessupport@olsontech.com 025-370403 REV X9 www.olsontech.com 12/16/03 TABLE OF CONTENTS SYSTEM OVERVIEW
More informationPrecision N Coaxial Calibration Kit
User Guide Precision N Coaxial Calibration Kit DC to 18 GHz Models: 8850CK10/11 8850CK20/21 8850-511 (A) 3/15 User Guide Precision N Coaxial Calibration Kit DC to 18 GHz Models: 8850CK10/11 8850CK20/21
More informationC-Band Solid-State Power Amplifiers
PCD6S350R, PCD6S400R C-Band Solid-State Power Amplifiers These high power solid-state amplifiers offer output powers of 350 or 400 watts across the standard 5.850 to 6.425 GHz satellite uplink band. Built
More informationInstalling the Cisco 2524 and Cisco 2525 Routers
CHAPTER 3 Installing the Cisco 2524 and Cisco 2525 Routers This chapter guides you through the installation of the Cisco 2524 and Cisco 2525 routers and includes the following sections: Required Tools
More informationUser Manual VX4234 Digital Multimeter Module
User Manual VX4234 Digital Multimeter Module 070-9139-02 This document applies for firmware version 1.00 and above. General Safety Summary Review the following safety precautions to avoid injury and
More informationEMSwitch RF Switch Plug-In Card
EMSwitch RF Switch Plug-In Card User Manual Model 7001-001 Model 7001-003 Model 7001-002 (not all models shown; Model 7001-004 External Switch Box not shown) ETS-Lindgren Inc. reserves the right to make
More informationSeries 8000 RF Signal Switch Solution
RF Signal Switch Solution Operation Manual Operation Manual, Part Number 07508000 006, Rev. B, Oct 7, 2014 All technical data and specifications in this publication are subject to change without prior
More informationSeries 8000 RF Signal Switch Solution
RF Signal Switch Solution Operation Manual Operation Manual, Part Number 07508000-006, Rev. A, May 17, 2013 All technical data and specifications in this publication are subject to change without prior
More informationModular Block Converter Systems
SATCOM Technologies Modular Block Converter Systems C-Band Hot-swappable, plug-in upconverter and downconverter modules Dual, redundant, hot-swappable power supplies Excellent frequency stability over
More informationAgilent. E5071C Network Analyzer 9 khz to 4.5/6.5/8.5 GHz 100 khz to 4.5/6.5/8.5 GHz (with bias tees) 300 khz to 14/20 GHz (with bias tees)
Agilent E5071C Network Analyzer 9 khz to 4.5/6.5/8.5 GHz 100 khz to 4.5/6.5/8.5 GHz (with bias tees) 300 khz to 14/20 GHz (with bias tees) E5092A Configurable Multiport Test Set Configuration Guide This
More informationInstallation Job Aid for VSP 4850GTS
Installation Job Aid for VSP 4850GTS Notices Release 6.1.0.0 NN46251-308 Issue 02.01 November 2017 Notice paragraphs alert you about issues that require your attention. The following paragraphs describe
More informationAgilent Technologies U3020AY03
Agilent Technologies U3020AY03 User s Guide Use this manual with the following documents: U3020AY04 User s Guide (U3020-90009) PNA Series Network Analyzer On-line Help System Manufacturing Part Number:
More informationUser Manual LKS-CD17SR 17 LCD Single Rail Console Drawer with Modular KVM Switch
User Manual LKS-CD17SR 17 LCD Single Rail Console Drawer with Modular KVM Switch LKS-CD19SR 19 LCD Single Rail Console Drawer with Modular KVM Switch Rev 2.0 Packing List ServerLink LKS-CD17SR / CD19SR
More informationInstallation Job Aid for VSP 4450GTX-HT- PWR+
Installation Job Aid for VSP 4450GTX-HT- PWR+ Notices Release 6.1.0.0 NN46251-305 Issue 02.01 November 2017 Notice paragraphs alert you about issues that require your attention. The following paragraphs
More informationCompact Redundancy Switch 2:1 RSCC-2
Compact Redundancy Switch 2:1 RSCC-2 The WORK Microwave Redundancy Switch RSCC-2 is compact solution for a 2:1 Redundancy System. It can be used for upconverters, downconverters, modulators and modulator-upconverters.
More informationInstallation Job Aid for Ethernet Routing Switch 3600 Series
Installation Job Aid for Ethernet Routing Switch 3600 Series Notices NN47213-303 Issue 03.01 November 2017 Notice paragraphs alert you about issues that require your attention. Following are descriptions
More informationInstalling the IPS 4345 and IPS 4360
CHAPTER 4 Installing the IPS 4345 and IPS 4360 Contents This chapter describes the Cisco IPS 4345 and the IPS 4360, and includes the following sections: Installation Notes and Caveats, page 4-1 Product
More informationHP 8714B Calibration
Wireless Circuits and Systems Laboratory Procedure #7 Calibrating the HP 8714 Network Analyzer This procedure describes the different types of calibrations that are available with the HP 8714 vector network
More informationMONITORING INTELLIRACK USER MANUAL
MONITORING INTELLIRACK USER MANUAL TABLE OF CONTENTS 1.0 INTRODUCTION..........................................................1 1.1 Overview...................................................................
More informationRFS Ferrocom Isolators/Circulators
RFS Ferrocom Isolators/Circulators A broad range of ferrite devices which are unequaled in performance, quality and reliability. Coaxial Isodapters Drop-in Waveguide Ferrocom Ferrite Division TABLE OF
More informationThe power behind competitiveness. Delta Infrasuite Power Management. Power Distribution Unit. User Manual.
The power behind competitiveness Delta Infrasuite Power Management Power Distribution Unit User Manual www.deltapowersolutions.com Save This Manual This manual contains important instructions and warnings
More informationInfiniium Q- Series Oscilloscopes
Service Guide Publication Number 54932-97006 October 2013 Agilent Technologies, Inc. 2012-2013 Infiniium 90000 Q- Series Oscilloscopes The Agilent Technologies Infiniium 90000 Oscilloscope at a Glance
More informationApplication Note FOR SMA Calibration Kit for VNA. LCAL06A A female calibration kit and used for DC ~ 6.0 GHz VNA test cable with male end connector.
Application Note FOR SMA Calibration Kit for VNA LCAL06A, LCAL06B, LCAL06C and LCAL09A are precision SMA calibration kits which provide accurate and reliable Short-Open-Load-Thru (SOLT) or Load-Reflect-Match
More informationRF switch network. RFB 2000, RFC 2010 or 2020
RFB 000, RFC 010 or 00 The can be configured to switch RF signals in a wide range of automatic test systems. Various switch configurations are available, connecting one input to either two or six outputs.
More information14.5U 4X SDR/DDR InfiniBand Switch Platform User s Manual. Rev 0.10
14.5U 4X SDR/DDR InfiniBand Switch Platform User s Manual 2 Copyright 2007. International and its licensors. All rights reserved. 14.5U 4X SDR/DDR InfiniBand Switch Platform User s Manual 3 Contents Contents
More informationOmnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual
Omnitron Systems Technology, Inc. 1 iconverter 19-Module Managed Power Chassis User s Manual 27 Mauchly, #201, Irvine, CA 92618 Phone: (949) 250-6510; Fax: (949) 250-6514 2 Omnitron Systems Technology,
More informationTRC-190 User s Manual
User s Manual Edition 3.2, May 2017 www.moxa.com/product 2017 Moxa Inc. All rights reserved. User s Manual The software described in this manual is furnished under a license agreement and may be used only
More informationM250 (M LL) Safety
M250 SAFETY M250 (M250-60-2LL) Safety Important Safety Information This document contains important instructions to use during installation of the Enphase M250 Microinverter. To reduce the risk of electrical
More informationAgilent 84904, 6, 7K/L Programmable Step Attenuators
Agilent 84904, 6, 7K/L Programmable Step Attenuators Data Sheet High Accuracy,Excellent Reliability, Long Life Features and description DC to 26.5 GHz, DC to 40 GHz frequency coverage Optional calibration
More informationSystem Storage EXP3000 Rack Installation Instructions
System Storage EXP3000 Rack Installation Instructions Review the documentation that comes with your rack cabinet for safety and cabling information. When you install the IBM System Storage EXP3000 in a
More informationM215 (M215-60) Safety
M215 QUICK INSTALL GUIDE M215 (M215-60) Safety Important Safety Information This document contains important instructions to use during installation and maintenance of the Enphase M215 Microinverter. To
More informationPicoVNA. USB vector network analyzer. Quick Start Guide
PicoVNA USB vector network analyzer Quick Start Guide CONTENTS 1. Introduction... 1 2. Safety information... 1 2.1 Symbols... 2 2.2 Maximum input and output ranges... 2 2.3 Grounding... 3 2.4 External
More informationKeysight Technologies E5071C Network Analyzer
Keysight Technologies E5071C Network Analyzer 9 khz to 4.5/6.5/8.5 GHz 100 khz to 4.5/6.5/8.5 GHz (with bias tees) 300 khz to 14/20 GHz (with bias tees) E5092A Configurable Multiport Test Set Configuration
More informationHigh Voltage Power Supplies
Source voltages up to 5kV and 10kV 1µA current measurement resolution Multi-channel programmable DC power supplies Low noise for precision sourcing and sensitive measurements; selectable filters reduce
More informationReplacing the Power Supply
APPENDIX B This appendix includes information on how to replace the power supply for the Cisco AS550XM universal gateway and contains the following sections: Safety Recommendations, page B-1 Required Tools
More informationKeysight MOI for USB Type-C Cable Assemblies Compliance Tests Using Keysight M937XA Multiport PXIe VNA
Revision 1.01 Feb-24, 2017 Universal Serial Bus Type-C TM Specification Revision 1.1 Keysight Method of Implementation (MOI) for USB Type-C TM Cables Assemblies Compliance Tests Using Keysight For Type-C
More information120Ra-1 Pentium III Processor Installation Insert
120Ra-1 Pentium III Processor Installation Insert PN: 455-01614-000 Proprietary Notice and Liability Disclaimer The information disclosed in this document, including all designs and related materials,
More informationKeysight 11636B APC-3.5 mm Power Divider DC to 26.5 GHz
Keysight 11636B APC-3.5 mm Power Divider DC to 26.5 GHz Operating and Service Manual Notices Keysight Technologies 1985, 2013, 2014 No part of this manual may be reproduced in any form or by any means
More informationAdvanced Test Equipment Rentals ATEC (2832)
Established 1981 Advanced Test Equipment Rentals www.atecorp.com 800-404-ATEC (2832) OPERATION AND MAINTENANCE MANUAL FOR SWR AUTOTESTERS AND BRIDGES 1. INTRODUCTION This manual provides product descriptions
More informationEDGES Receiver Calibration Steps Tom Mozdzen
EDGES Receiver Calibration Steps Tom Mozdzen January 23, 2018 This document provides a description of the steps required to calibrate an EDGES receiver. Detailed pictures and instrument settings as well
More informationApplication Note. Use of Palm Switches with QuadTech Hipot Testers
Application Note Use of Palm Switches with QuadTech Hipot Testers Operator safety is an important aspect to consider when dealing with high voltage devices and instruments such as hipot testers. To improve
More informationInstallation Note. Removable Hard Disk Drive Upgrade Kit. For All PNA Series RF Network Analyzers. Network Analyzer Model Number
Installation Note Removable Hard Disk Drive Upgrade Kit For All PNA Series RF Network Analyzers Network Analyzer Model Number E8356A, E8357A, E8358A E8801A, E8802A, E8803A N3381A, N3382A, N3383A Upgrade
More informationTABLE OF CONTENTS 1. OVERVIEW... 1
TABLE OF CONTENTS 1. OVERVIEW... 1 1.1. SPECIFICATIONS... 1 1.1.1. Electrical... 1 1.1.2. Compliance... 2 1.1.3. Physical... 2 1.2. COOLING... 2 1.2.1. Fan Exhaust... 2 1.3. MOUNTING... 3 1.4. POWER...
More informationRacal Instruments 1257A. Scalable RF Interface Unit. Product Information. The Racal Instruments 1257A is a Commercial-Off-The
Racal Instruments 1257A Scalable RF Interface Unit The is a sixth-generation RFIU design with four Commercial Off-The-Shelf (COTS) options from 1U to 4U. It comes with a new easy-to-use LXI Core 2011-compliant
More informationService Manual. P GHz Active Probe
Service Manual P7240 4 GHz Active Probe 071-1056-00 Warning The servicing instructions are for use by qualified personnel only. To avoid personal injury, do not perform any servicing unless you are qualified
More informationDANTE BRIDGE. Operation Manual
DANTE BRIDGE Operation Manual Important Safety Instructions Important safety instructions Please carefully read following instructions and safety information and retain for future reference. Heed all warnings
More informationMODULUS 21 Power Distribution Unit (PDU) Replacement. Overview A. Introduction
Page 1 of 16 MODULUS 21 Power Distribution Unit (PDU) Replacement Overview Introduction This notice explains how to replace the AC Power Distribution Unit (PDU), also known as a Power Distribution Assembly
More informationWarning - Read the entire VDI User guide for this product prior to operation.
VDI USER GUIDE Product: 1900 GHz Amplifier Multiplier Chain Serial Number(s): VDI-AMC-S186B (upgrade) Amplifier: Spacek Labs A286-2XWB-33 SN 8M18 Components: VDI 52R1X2 1-17, VDI 110R1X2 1-14, VDI 200R2X2
More informationAdapter 2.92 mm-f to 2.92 mm-m
Coaxial Adapter 2.92 mm-f to 2.92 mm-m 50Ω DC to 40 GHz The Big Deal Ultra-wideband, DC-40 GHz Flat response Low insertion loss, 0.09 db Excellent, 1.04:1 CASE STYLE: DJ1861 Product Overview Mini-Circuits
More informationKeysight Combiner and Mechanical Switches Upgrade Kit
Keysight Combiner and Mechanical Switches Upgrade Kit To Upgrade PNA-X N5247A/B Option 419 to Option 423 Upgrade Kit Order Number: N5247AU-927 and N5247BU-423 Keysight Kit Number: N5247-60104 Installation
More informationDell MD1280 Storage Enclosure Getting Started Guide
Dell MD1280 Storage Enclosure Getting Started Guide Regulatory Model: SP-2584, E11J Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your computer.
More informationMPI TS150-AIT 150 mm Manual Probe System
MPI TS150-AIT 150 mm Manual Probe System Industry s first explicitly designed 150 mm probe system providing accurate tests for mm-wave, THz, and automated impedance tuner applications FEATURES / BENEFITS
More informationModel 2380 Rack-Mount Kit
Keithley Instruments 28775 Aurora Road Cleveland, Ohio 44139 1-800-935-5595 http://www.tek.com/keithley Model 2380 Rack-Mount Kit Installation Instructions Introduction The Model 2380 Fixed Rack-Mount
More information200 VA bis VA 10 V bis 80 V 2 A bis 320 A. Source-Sink NL
200 VA bis 3.120 VA 10 V bis 80 V 2 A bis 320 A NL AC, NL Series Interface overview RS-232 X USB X GPIB O LAN O System bus O Analog X Analog isolated O X Standard O Option / not available NL1V20C40 2-quadrant
More information