GRUNDFOS DATA BOOKLET. Conex DIS-C. Measuring amplifiers and controllers. For conductivity measurement (conductive, inductive)
|
|
- Kory Barber
- 5 years ago
- Views:
Transcription
1 GRUNDFOS DATA BOOKLET Measuring amplifiers and controllers For conductivity measurement (conductive, inductive)
2 Table of contents 1. Product features 3 Conex DIS 3 Conex DIS-C 3 2. Identification 4 Type key, Conex DIS-C, controller 4 Type key, Conex DIS-C, prepacked 4 3. Technical data 5 Conex DIS-C, controller 5 Conductive measuring cells for conductivity measurement 6 Inductive measuring cells for conductivity measurement 6 4. Product selection 7 Conex DIS-C, controller for conductive measurement 7 Conex DIS-C, controller for inductive measurement 7 Conex DIS-C, prepacked systems for conductive measurement 8 Conex DIS-C, systems for inductive measurement 8 5. Accessories 9 Electrode holders for conductive measuring cells 9 Armatures for inductive measuring cells 9 6. Further product documentation 11 WebCAPS 11 WinCAPS 12 2
3 1 1. Product features Conex DIS Conex DIS (Dosing Instrumentation Standard) are simple, cost-efficient units for amplifying and control. Fitted with a powerful 16-bit microprocessor system and offering a choice of settings, Conex DIS models ensure high water quality while reducing the volumes of chemicals dosed. Simplicity and efficiency are combined. Product features Conex DIS-C Measuring amplifier and controller for conductivity measurement Conex DIS-C measures conductivity in a range of applications from bottle-washing to harsh desalination. Conex DIS-C is available with a choice of conductive or inductive measuring cells. The maximum operating temperature and pressure depend on the measuring cells used. Measuring cell Max. pressure [bar] Max. temperature [ C] Conductive 16 (at 25 C) 135 Inductive 10 (at 20 C) 90 Conex DIS-C models with inductive measuring cells are ideal for aggressive media, because the measuring coils do not come into contact with the sample water. Display languages: German, English and French. Monitoring and control parameters Conductivity (using either conductive or inductive measuring cells). TM Fig. 1 Conex DIS-C In the following chapters, the Conex DIS-C measuring amplifiers and controllers are simply referred to as "controllers". 3
4 2 Identification 2. Identification Type key, Conex DIS-C, controller Example: DIS-C 1-CC W-G Example: DIS-C 1-CC W -G Measuring amplifier and controller DIS-C Dosing Instrumentation Standard for conductivity measurement Input parameter 1 CC Conductivity, conductive CI Conductivity, inductive Mounting W Wall-mounted P Panel-mounted Voltage G 1 x 230 V, 50/60 Hz H 1 x 120 V, 50/60 Hz Type key, Conex DIS-C, prepacked Example: DIS-C-P, CC-R1-F-PVC, P-G Example: DIS-C -P CC -R1 -F -PVC P -G Model DIS-C Dosing Instrumentation Standard for conductivity measurement Mounting options P Prepacked Sensor CC Conductivity, conductive CI Conductivity, inductive Measuring range R µs/cm (conductive measurement only) R µs/cm (conductive measurement only) R µs/cm (conductive measurement only) Armature type F Flow-type armature I Immersion armature (inductive measurement only) X No armature Armature material PVC Polyvinyl chloride PP Polypropylene Controller mounting option W Wall-mounted P Panel-mounted Voltage G 1 x 230/240 V, 50/60 Hz H 1 x 115/120 V, 50/60 Hz 4
5 3 3. Technical data Conex DIS-C, controller Dimensions Technical data General data TM Fig. 2 Ø Conex DIS-C, wall-mounted TM Electronics Display Display mode Operation Languages Password Compensation Measuring range Cell constant Inputs/outputs Analog output (0-20 ma or 4-20 ma) Digital input Enclosure class Permissible temperature range Permissible relative air humidity Mains voltage Weight Microcontroller-operated Two-line, alphanumeric LCD measured values as physical variables temperature indication operational and status messages five membrane keys code menu English, German, French Operational protection with code Temperature compensation Automatic internal selection of: measuring range measuring frequency measuring tension Adjustable Galvanic separation Galvanic separation, can be used for measured value or continuous controller Controller stop input Wall-mounted: IP65 Panel-mounted: IP54 (only conductive) Operation: 0 to +50 C Storage: -20 to +65 C Max. 90 % (non-condensing) 230 V - 10 %/+ 6 % or 130 V - 10 %/+ 6 % Approx. 0.8 kg 96 x 96 Fig. 3 ca. 129 ca. 137 Conex DIS-C, panel-mounted 90 x 90 TM Control functions Operation modes Relays Manual or automatic Alarm relay Control relays 1 + 2: Limit-value controller Pulse-pause controller Pulse-frequency controller Continuous controller (analog output: 4-20 ma) Limit values Adjustable to physical variable within the measuring range Setpoint selection 0 to 100 % of the measuring range Proportional band X p 0.1 to 3000 % Reset time T N 1 to 3000 s, resolution 1 s Control direction Upward or downward control, with the corresponding controller types Alarm relay delay 0 to 999 seconds 5
6 3 Technical data Conductive measuring cells for conductivity measurement PVDF body with inserts made of PVDF and FKM Two coaxial stainless-steel electrodes Integrated platinum resistance thermometer Screw-in thread, 3/4" Long service life. Inductive measuring cells for conductivity measurement Internal ring-shaped measuring coils Integrated temperature sensor Particularly suitable for aggressive liquids High chemical resistance, resistent to dirt Sensor not in contact with liquid Gasket and lock nut are included in a standard delivery. TM Fig. 4 Conductive measuring cell Fig. 6 Inductive measuring cell Technical data Temperature range 0 to 135 C Maximum operating pressure 16 bar (at 25 C) Connecting cable max. 50 metres Material of cell body PVDF Material of electrode Stainless steel Temperature sensor Pt100 Thread 3/4" Dimensions Technical data Dimensions G 3/4 100 TM Material PP Max. temperature 90 C Max. pressure at 20 C 10 bar Max. pressure at 60 C 6 bar Accuracy ± 2 % Integrated temperature sensor NTC Max. cable length between sensor and amplifier 16 metres (with extension cable) Connection cable 6 metres Thread 1/2" Measuring range ms/cm ms/cm 0-20 ms/cm 0-2 ms/cm Fig. 5 Ø20 Conductive measuring cell TM ±0.2 Ø TM Order data Fig. 7 Inductive measuring cell Description Conductive measuring cell Measuring range Cell constant Product No µs/cm c = µs/cm c = µs/cm c = Order data Description Inductive measuring cell for conductivity measurement, including 6 metres of permanently connected cable Product No
7 4 4. Product selection Conex DIS-C, controller for conductive measurement Controller Conex DIS-C 230/240 V Voltage 115/120 V Controller mounting Panel-mounted Wall-mounted Enclosure material Polystyrene Noryl Enclosure class IP65 IP54 Input parameter 1 Conductivity conductive measurement Conductivity inductive measurement Type key Product number DIS-C, 1-CC, P-G DIS-C, 1-CC, W-G DIS-C, 1-CC, P-H DIS-C, 1-CC, W-H Product selection Conex DIS-C, controller for inductive measurement Voltage Controller mounting Enclosure material Enclosure class Input parameter 1 Controller Conex DIS-C 230/240 V 115/120 V Panel-mounted Wall-mounted Polystyrene Noryl IP65 IP54 Conductivity conductive measurement Conductivity inductive measurement Type key Product number DIS-C, 1-CI, W-G DIS-C, 1-CI, W-H
8 4 Product selection Conex DIS-C, prepacked systems for conductive measurement 230/240V / 50/60Hz Voltage 115/120V / 50/60Hz Controller mounting options Panel mounted Wall mounted Enclosure material ABS Noryl Enclosure class IP65 IP54 Measuring principle Conductivity, conductive Conductivity, inductive Included Cell included Not included µs/cm Measuring range µs/cm µs/cm ms/cm (in 4 ranges) Flow Armature type Immersion No armature included Armature material PP PVC Type key Product number DIS-C-P, CC-R1-F-PVC. P-G DIS-C-P, CC-R1-X. P-G DIS-C-P, CC-R2-F-PVC. P-G DIS-C-P, CC-R2-X. P-G DIS-C-P, CC-R3-F-PVC. P-G DIS-C-P, CC-R3-X. P-G DIS-C-P, CC-R1-F-PVC. W-G DIS-C-P, CC-R2-F-PVC. W-G DIS-C-P, CC-R2-X. W-G DIS-C-P, CC-R3-F-PVC. W-G DIS-C-P, CC-R1-F-PVC. P-H DIS-C-P, CC-R1-X. P-H DIS-C-P, CC-R2-F-PVC. P-H DIS-C-P, CC-R2-X. P-H DIS-C-P, CC-R3-F-PVC. P-H DIS-C-P, CC-R3-X. P-H DIS-C-P, CC-R1-F-PVC. W-H DIS-C-P, CC-R1-X. W-H DIS-C-P, CC-R2-F-PVC. W-H DIS-C-P, CC-R2-X. W-H DIS-C-P, CC-R3-F-PVC. W-H DIS-C-P, CC-R3-X. W-H Conex DIS-C, prepacked systems for inductive measurement Easy product selection: Choose a controller: 115 or 230 V, wall-mounted (not available for panel-mounting); There is only one measuring cell version; Choose a type of armature: immersion (PP) or flow (PP or PVC); If you need more than 6 metres of cable, choose the extension cable for additional 10 metres. 8
9 5 5. Accessories Armatures for conductive measuring cells Easy installation and commissioning Reliable measurement Quick dismantling of the measuring cell for cleaning or maintenance. Dimensions 204 Armatures for inductive measuring cells Easy installation and commissioning Reliable measurement Quick dismantling of the measuring cell for cleaning or maintenance. Flow armature Technical data Accessories DN 25 TM Material PP or PVC Max. temperature 90 C (PP), 40 C (PVC) Nominal width DN 50 Length 102 mm Dimensions PP PVC Fig. 8 Flow armature for conductive measuring cells Order data Description Flow armature, PVC, DN 25 Cable Max. temperature [ C] Max. pressure [bar] Product No Description Length [m] Product No Standard cable, single-screening, 4- wire, for conductive measuring cell (maximum length 50 m) Fig. 9 Flow armature for inductive measuring cells Order data Description Product No Flow armature, PP Flow armature, PVC TM
10 5 Accessories Immersion armature Technical data Material PP Max. temperature 90 C Diameter 25 mm Immersion depth max. 900 mm Length 1000 mm Dimensions TM Ø25 Ø37 Ø59 Fig. 10 Immersion armature with inductive measuring cell Order data Description Product No Immersion armature, PP Cable Description Extension cable, 4-wire, individually screened, type CAT B 23290, top line P22, 10 metres Product No
11 6 6. Further product documentation WebCAPS WebCAPS is a Web-based Computer Aided Product Selection program available on WebCAPS contains detailed information on more than 220,000 Grundfos products in more than 30 languages. Information in WebCAPS is divided into six sections: Catalogue Literature Service Sizing Replacement CAD drawings. Further product documentation Catalogue Based on fields of application and pump types, this section contains the following: technical data curves (QH, Eta, P1, P2, etc.) which can be adapted to the density and viscosity of the pumped liquid and show the number of pumps in operation product photos dimensional drawings wiring diagrams quotation texts, etc. Literature This section contains all the latest documents of a given pump, such as data booklets installation and operating instructions service documentation, such as Service kit catalogue and Service kit instructions quick guides product brochures. Service This section contains an easy-to-use interactive service catalogue. Here you can find and identify service parts of both existing and discontinued Grundfos pumps. Furthermore, the section contains service videos showing you how to replace service parts. 11
12 0 1 6 Further product documentation Sizing This section is based on different fields of application and installation examples and gives easy step-by-step instructions in how to size a product: Select the most suitable and efficient pump for your installation. Carry out advanced calculations based on energy, consumption, payback periods, load profiles, life cycle costs, etc. Analyse your selected pump via the built-in life cycle cost tool. Determine the flow velocity in wastewater applications, etc. Replacement In this section you find a guide to selecting and comparing replacement data of an installed pump in order to replace the pump with a more efficient Grundfos pump. The section contains replacement data of a wide range of pumps produced by other manufacturers than Grundfos. Based on an easy step-by-step guide, you can compare Grundfos pumps with the one you have installed on your site. When you have specified the installed pump, the guide will suggest a number of Grundfos pumps which can improve both comfort and efficiency. CAD drawings In this section, it is possible to download 2-dimensional (2D) and 3-dimensional (3D) CAD drawings of most Grundfos pumps. These formats are available in WebCAPS: 2-dimensional drawings:.dxf, wireframe drawings.dwg, wireframe drawings. 3-dimensional drawings:.dwg, wireframe drawings (without surfaces).stp, solid drawings (with surfaces).eprt, E-drawings. WinCAPS WinCAPS is a Windows-based Computer Aided Product Selection program containing detailed information on more than 220,000 Grundfos products in more than 30 languages. The program contains the same features and functions as WebCAPS, but is an ideal solution if no internet connection is available. WinCAPS is available on DVD and updated once a year. Fig. 11 WinCAPS DVD Subject to alterations. 12
13 13
14 14
15 15
16 Being responsible is our foundation Thinking ahead makes it possible Innovation is the essence ECM: The name Grundfos, the Grundfos logo, and the payoff be think innovate are registered trademarks owned by Grundfos Holding A/S or Grundfos A/S, Denmark. All rights reserved worldwide. GRUNDFOS A/S. DK-8850 Bjerringbro. Denmark Telephone:
GRUNDFOS ALLDOS DATA BOOKLET. Conex DIS-C. Measuring amplifiers and controllers for conductivity measurement 50/60 Hz
GRUNDFOS ALLDOS DATA BOOKLET Measuring amplifiers and controllers for conductivity measurement 50/60 Hz TM042232 if Contents Product features Conex DIS 3 3 Identification Type key,, controller 4 Type key,,
More informationGRUNDFOS ALLDOS DATA BOOKLET. DME and DMS DIGITAL DOSING
GRUNDFOS ALLDOS DATA BOOKLET DIGITAL DOSING s Wiring diagram, -A (0-8 l/h) See pages 6 and 8 for input/output data. "NO" black "NC" blue (culus: white) "COM" brown (culus: green) Control cable : m cable:
More informationCR, CRN high pressure
GRUNDFOS DATA BOOKLET CR, CRN high pressure Vertical multistage centrifugal pumps 5/6 Hz Contents Product Data Performance range 3 Product range 4 Applications 4 CRNE 1 and 3 HS 5 CRN 5, 1, 15, SF 6 x
More informationSMART Digital DDA DDC DDE Modular. Simple. Intelligent.
DDA DDC DDE Modular. Simple. Intelligent. GRUNDFOS ALLDOS Digital DOSING SINCE 1999 GRUNDFOS ALLDOS Digital Dosing SINCE 1999 GRUNDFOS ALLDOS Digital DOSING SINCE 1999 FROM THE INVENTOR OF DIGITAL TM DOSING
More informationGRUNDFOS DATA BOOKLET. Dewatering pumps 50 Hz
GRUNDFOS DATA BOOKLET Dewatering pumps 50 Hz Table of contents 1. Introduction 3 Applications 3 Pumped liquids 3 Constructional features 3 2. Identification 5 Type key 5 3. Selection of pump Ordering a
More informationGRUNDFOS DATA BOOKLET. Dedicated Controls. 50/60 Hz
GRUNDFOS DATA BOOKLET 50/60 Hz Contents 1. General description Introduction 3 Data communication 4 2. Features and benefits Features and benefits 5 3. Type key Control cabinet 7 4. Product description
More informationHow to build a Conductivity Measurement System
How to build a Measurement System F B E C D A A Immersion system in open basin B Flow-through system C 1/2 pipe mounted system D 3/4 pipe mounted system E Side-entry system in vessel F Top-entry system
More informationLenntech GRUNDFOS DATA BOOKLET. CME 10. Horizontal, multistage centrifugal pumps 50/60 Hz
Lenntech info@lenntech.com www.lenntech.com GRUNDFOS DATA BOOKLET CME 1 Horizontal, multistage centrifugal pumps 5/6 Hz General description CME Stainless-steel version Fig. 2 Grundfos CME pumps Cast-iron
More informationGRUNDFOS DATA BOOKLET. Grundfos small pumping stations
GRUNDFOS DATA BOOKLET Grundfos small pumping stations Grundfos small pumping stations Table of contents 1. Introduction 3 Introduction 3 2. Pumped liquids 5 Pumped liquids 5 3. Identification 6 4. Selection
More informationSM ART Digital DDA DDC DDE Modular. Simple. Intelligent.
SM ART Digital DDA DDC DDE Modular. Simple. Intelligent. GRUNDFOS ALLDOS Digital DOSING SINCE 1999 GRUNDFOS ALLDOS Digital Dosing SINCE 1999 GRUNDFOS ALLDOS Digital DOSING SINCE 1999 FROM THE INVENTOR
More informationDigital O.R.P. Transmitter Type 8206
Advantages / Benefits Design Compact O.R.P. Transmitter Type 8206 The O.R.P. transmitter compactly combines an O.R.P. sensor and an electronic with display in splash-proof plastic NEMA 4 (IP 65) enclosure.
More informationEchotouch, EchoSpan & EchoSwitch Ultrasonic Liquid
Echotouch, EchoSpan & EchoSwitch Ultrasonic Liquid The Echotouch, EchoSpan and EchoSwitch are innovative ultrasonic liquid level sensor families that replace float, conductance and pressure sensors that
More informationDigital ph-transmitter. Type Advantages / Benefits. Design. Application
Advantages / Benefits Easy System integration by Easy LINK provides low cost of ownership Programmable ph-transmitter functions for easy ph-measuring system solutions Compact version with integrated ph-electrodes
More informationGRUNDFOS MAGNA1 MODEL C THE NEW MAGNA1 A SIMPLE AND EFFICIENT SOLUTION FULL RANGE OF CIRCULATOR PUMPS TO GET THE SIMPLE JOBS DONE
GRUNDFOS MAGNA1 MODEL C THE NEW MAGNA1 A SIMPLE AND EFFICIENT SOLUTION FULL RANGE OF CIRCULATOR PUMPS TO GET THE SIMPLE JOBS DONE 2 GRUNDFOS MAGNA1 MODEL C SIMPLICITY AT ITS MOST EFFICIENT Looking for
More informationLevel Measurement Continuous level measurement - Ultrasonic transmitters
Overview Configuration is a short-range integrated ultrasonic level transmitter. This general purpose, 2-wire, to 20 ma loop powered transmitter is ideal for liquids, slurries, and bulk materials in open
More informationLevel sensor for monitoring the level of liquid media
Level sensor MG Level sensor for monitoring the level of liquid media Characteristics Level sensor output 4 20mA or Resistance output in three-wire potentiometer circuit Temperature range: -30 C to 150
More informationDigital ph-controller
Advantages / Benefits Design Compact ph-controller The ph-controller compactly combines a ph-sensor and a PID-controller with display in a splash-proof plastic NEMA 4 enclosure. The sensor component consists
More informationDISSOLVED OXYGEN MEASUREMENT
DISSOLVED OXYGEN MEASUREMENT ACTEON 2030 TRANSMITTER Potentiometric measurement technology Robust, watertight, easy to install, Widescreen graphic display: instant measurements, trend line, relay state,
More informationEasy Flow Indicator Magnetisch-Induktiver Durchflussmesser. Type 8024 For Insertion Fittings. Analog Flow Rate Indicator, 1/2"-16"; P=87 PSI
Analog Flow Rate Indicator, 1/2"-16"; P=87 PSI Advantages / Benefits Reduced costs of ownership up to 6% Economic integration in pipe systems without any additional piping Shows flow rate with a clear,
More informationPHYSICS Digital Measuring Devices
PHYSICS Digital Measuring Devices For precise measurements in meteorology, chemical, pharmaceutical and food industries, biotechnology, water analytics, science and research as well as industrial quality
More informationResolution 1 F (1 C) single point; degrees C or Calibration single or dual point Calibration F
RMS Rainwater Harvesting Series 100 Controller Specifications Measurement Performance Contacting Conductivity ph Range 0-10,000 µs/cm Range -2 to 16 ph units Resolution 1 µs/cm Resolution 0.01 ph units
More informationBXD17 Series. Features. Analytical instrumentation for your measurement applications.
BXD17 Series Analytical instrumentation for your measurement applications. Features Single parameter instrument with temperature measurement capabilities Custom IP66 NEMA 4X (144 x 144mm) enclosure Versatile
More informationPrecision digital measuring device PHYSICS 51
Precision digital measuring device PHYSICS 51 Digital measuring device for thermocouples, NTC resistance thermometers, infrared temperature probes, capacitive humidity probes. Technical data PHYSICS 51
More informationLevel Measurement Continuous level measurement - Ultrasonic transmitters
Overview Configuration is a short-range integrated ultrasonic level transmitter. It is intrinsically safe (ATEX, CSA, FM, IECEx, NEPSI), 2 wire, to 20 ma loop powered, ideal for liquids, slurries, and
More informationProduct data sheet accessories control and regulation Accessories AIRWIN
Product data sheet accessories control and regulation BO-CT1 Continuous controller Item no. 6100101 Control of humidification performance BO-CT1 Option board 2 binary inputs Item no. 002212 Setpoint switching,
More informationLDCL DIGITAL CONTROLLER OPERATING MANUAL
This manual contains important safety informations about installation and use of this equipment. Ignoring this informations could result in injuries or damages. It is strictly forbidden to use this equipment
More informationConductivity Transmitters
Conductivity Transmitters CDTX-90 Series Starts at $ 576 Electronics Only Display in µs, ms, kω, MΩ, ppm (TDS) Simulate Function Programmable Temperature Compensation Relay Options Dual Output Option Allows
More informationModel KMF 720 Constant climate chambers with expanded temperature / humidity range
Model KMF 720 Constant climate chambers with expanded temperature / humidity range The BINDER KMF ensures absolutely constant test conditions throughout the testing area. A big advantage of this constant
More informationSITRANS F C. Transmitter MASS 6000 Ex d compact/remote 3/195
Overview MASS 6000 is based on the latest developments within digital signal processing technology engineered for high performance, fast flow step response, fast batching applications, high immunity against
More informationOperating Instruction
Level and Pressure Operating Instruction VEGASWING 71 A Contents Contents Safety information... 2 1 Product description 1.1 Function and configuration... 3 1.2 Functional principle... 3 1.3 Technical data...
More informationS M ART D ig ital DDA DDC DDE Modular. Simple. Intelligent.
CALL TOLL FREE 877-742-2878 FOR SALES AND SUPPORT. GRUNDFOS DOSING AND DISINFECTION CLICK HERE TO RETURN TO WEBSITE. G OSIN LD TA GRU N FROM THE INVENTOR OF DF OS G OSIN LD TA GI DI DIGITAL DOSING SINCE
More informationTHE SMART DIGITAL RANGE
GRUNDFOS DOSING AND DISINFECTION FLEIBILITY Digital dosing since 2000 SAFETY RELIABILITY THE SMART DIGITAL RANGE Accurate digital diaphragm dosing pumps A SOLUTION FOR ALL DOSING APPLICATIONS Whether your
More informationJUMO CTI-500. Inductive Conductivity/Concentration and Temperature Transmitter with switch contacts. Type Brief description.
Page 1/17 JUMO CTI-500 Inductive Conductivity/Concentration and Temperature Transmitter with switch contacts Type 202755 Brief description The device is used for the measurement/control of conductivity
More informationPrecision Hand-held Thermometer
Precision Hand-held Thermometer measuring monitoring analysing Measuring range from -220 C... +1768 C Measuring accuracy starting with ±0.03% MV Large selection of temperature probes PT 100 or thermocouple
More informationOperating Manual LF1-LF4 i
Operating Manual Oct. 2005 Fillerkampsweg 1 5 31832 Springe OT Eldagsen Tel.: 05044/887-0 (Fax: -99) E-Mail: info@iotronic.de Internet: http://www.iotronic.de Page 3 Contents 1.0 General Guidelines for
More informationJUMO ecotrans ph 03 Microprocessor transmitter/ switching device for ph/redox voltage and temperature
Page 1/7 JUMO ecotrans 03 Microprocessor transmitter/ switching device for /Redox voltage and temperature with a 2-line LCD for mounting on a 35 mm DIN rail Brief description Depending on the configuration,
More informationEchotouch, EchoSpan & EchoSwitch Ultrasonic Liquid
Echotouch, EchoSpan & EchoSwitch Ultrasonic Liquid The Echotouch, EchoSpan and EchoSwitch are innovative ultrasonic liquid level sensor families that replace float, conductance and pressure sensors that
More informationConductivity-Panelmeter LF 9648 Conductivity measurement with 2-and 4-electrode cells
Conductivity-Panelmeter LF 9648 Conductivity measurement with 2-and 4-electrode cells Features M LED-Display 14.2 mm red M Indicating range 2000(0) Digit M Measuring ranges programmable from 0... 2.000
More information200CRS Single-Channel Conductivity/Resistivity Measurement System THORNTON. Leading Pure Water Analytics
THORNTON Leading Pure Water Analytics - NIST Traceable Calibration - Two Analog Outputs Standard - Three-Wire Temperature Measurement - Wide Range of Sensor and Cable Selections 200CRS Single-Channel Conductivity/Resistivity
More informationJUMO PINOS L01. Calorimetric flow sensor. Brief description. Special features. Customer benefits. Data Sheet
sales@jumo.co.uk info.us@jumo.net Page 1/9 JUMO PINOS L01 Calorimetric flow sensor Brief description The JUMO PINOS L01 flow sensor serves the measuring and monitoring of flow velocities of water and aqueous
More informationSonoSelect 10 and SonoSafe 10 energy meters
SonoSelect 10 and SonoSafe 10 energy meters Description The Danfoss SonoSelect 10 and SonoSafe 10 are ultrasonic compact energy meters intended for measuring energy consumption in heating applications
More informationHMT330 Series Humidity and Temperature Transmitters for Industrial Applications
HMT330 Series Humidity and Temperature Transmitters for Industrial Applications The HMT330 transmitter family has the solution for demanding industrial humidity measurements. Six models for demanding industrial
More informationRange. Body Material. Max. Press ms K=0, C 4 bar Glass Graphite 13.5 PG Full integrated 5-meter cable
Conductivity Range Conductivity 0 20 μs; 0 200 μs; 0 2.000 μs; 0 20.000 μs; 0 200.000 μs Resolution 0,01 μs; 0,1 μs; 1 μs; μs Avaiable versions with double parameter 4238-22 [ph/orp - Conductivity] 4293-22
More informationFloat Flow Meter. Flow measurement for translucent liquids and gases DN10 to DN65 mm. Technical data Orifice DN 10 to 65
Float Flow Meter Flow measurement for translucent liquids and gases DN10 to DN65 mm If a medium sufficient flow rate flows from bottom to top through a vertically inserted measuring tube, then the floated
More informationHand-Held Thermometer Model CTH 6200
Testing and Calibration Technology Hand-Held Thermometer Model CTH 6200 WIKA Data Sheet CT 51.01 Applications Service industry Measurement and and control laboratories Industry (laboratory, workshop and
More information703 Laboratory Conductivity Meter
703 Laboratory Conductivity Meter Sensoface Sensoface monitors the sensor and measuring equipment and provides information on sensor selection and handling. It reports clock memory loss and requests regular
More informationHI 9828 Multiparameter Water Quality Meter...
HI 9828 Multiparameter Water Quality Meter... Backlit LCD can display up to 12 Measurements at a time Feature Highlights Display up to 12 parameters Graphic LCD with backlight Meter features IP67 and probe
More informationFloat Switches with Permanent Magnet For Vertical Installation Model RSM
Level Measurement Float Switches with Permanent Magnet For Vertical Installation Model RSM WIKA Data Sheet LM 30.01 Applications Level measurement for almost all liquid media Pump/level control and monitoring
More informationSonoSelect and SonoSafe energy meters
SonoSelect and SonoSafe energy meters Description The Danfoss SonoSelect and SonoSafe are ultrasonic compact energy meters intended for measuring energy consumption in heating applications for billing
More informationThe Model 703 offers a wide range of practical features to meet the numerous requirements of everyday measuring tasks.
Laboratory Meters The requirements for lab measurements become stricter every day. Quality assurance and measurement documentation in accordance with GLP are a must in many areas. 703 Laboratory Conductivity
More informationHI 9828 Multiparameter Water Quality Meter...
HI 9828 Multiparameter Water Quality Meter... Backlit LCD can display up to 12 Measurements at a time Feature Highlights Display up to 12 parameters Graphic LCD with backlight Meter features IP67 and probe
More informationfor measuring ph values and redox potential, conductivity and dissolved oxygen Content
for measuring ph values and redox potential, conductivity and dissolved oxygen Content Portable ph meters with GLP functions handylab ph 11 and handylab ph 12 Page 32 Technical data handylab LF 11, handylab
More informationLevel Transmitter. Table of dimensions see page 4. Total length B Installation length A SW55 Ø 55 Ø 75
Level Transmitter Construction The GEMÜ level transmitter has an immersion tube with reed contacts and a chain of resistors which are triggered by a float with an integrated permanent magnet. A threaded
More informationDewatering pumps for raw water pumping GRUNDFOS DW RANGE. Dewatering pump kw
Dewatering pumps for raw water pumping GRUNDFOS DW RANGE Dewatering pump 0.7-20 kw efficient state-of-art dewatering pumps Unique user benefits The Grundfos DW pumps form part of a complete range of wastewater
More informationInCos-P Pressure sensor 20 Pa Pa
InCos-P Pressure sensor 20 Pa... 7.500 Pa Electrical pressure / differential pressure sensors 24 VAC/DC supply voltage, 0...10 V / (0) analogue Compact. Easy installation. Universal. Cost effective. Safe.
More informationElectrochemistry Meters. Series SD (IP 67 waterproof) Electrochemistry Meters
Electrochemistry Meters Series SD (IP 67 waterproof) 82 The new AQUALYTIC SD series comprises a range of compact, easy-to-use, hand-held instruments for the accurate measurement of ph, ORP, Con, TDS or
More informationTABLE OF CONTENTS INTRODUCTION. 3. Analog Input Analog Output Digital Input Digital Output OPERATIONAL DESCRIPITON.. 7 PROGRAMMING AND INITIAL SETUP.
DIVERSIFIED HEAT TRANSFER SERIES 700 STEAM GENERATOR CONTROLLER INSTRUCTION MANUAL VISIT OUR WEBSITE AT SIGMACONTROLS.COM SERIES 700 DHT STEAM GENERATOR MANUAL 042514 2 TABLE OF CONTENTS INTRODUCTION.
More informationAutomation System TROVIS 5400 District Heating Controller TROVIS 5475
Automation System TROVIS 5400 District Heating Controller TROVIS 5475 On-off or three-step controller designed for wall or panel mounting (Front frame dimensions: 144 mm x 96 mm) Application Controller
More informationLenntech BMP GRUNDFOS DATA BOOKLET. High-pressure piston pumps 50/60 Hz
Lenntech GRUNDFOS DATA BOOKLET BMP High-pressure piston pumps 50/60 Hz Contents Product data Introduction Page 3 Features and benefits Page 3 Applications Page 3 Pumped liquids Page 3 key Page 4 Motor
More informationNeon pr. ph/ ORP measurement. Applications. Description
Easy handling by graphical menue Fitting for your application by modular setup Simple firmware update and configuration using SD-card Applications Process Water Drinking Water / Beverages Waste Water Treatment
More informationAnalog outputs Output 1 + 2: 0(4) 20 ma or 0 10 V. Configurable as - analog process value output - continuous controller output (PID action)
Page 1/10 JUMO AQUIS 500 ph Transmitter/Controller for ph, ORP, NH 3 (ammonia) concentration and temperature Brief description The instrument is used for measuring/controlling the ph, ORP or NH 3 (ammonia)
More informationCR, CRN high pressure
GRUNDFOS PRODUCT GUIDE CR, CRN high pressure Vertical multistage centrifugal pumps 6 z Contents Mission 3 Product overview Performance range Product range 5 Applications 6 CRNE 1 and 3 S 7 CRN 5, 1, 15,
More informationCapacitive Sensors. Capacitive sensors for object detection
sensors for object detection Balluff capacitive sensors BCS are used for object and level detection. They measure all materials even non-conductive ones such as liquids, granules and powders in direct
More informationMMT330 Series Moisture and Temperature Transmitters for Oil
MMT330 Series Moisture and Temperature Transmitters for Oil Features Continuous online measurement of moisture in oil Ball-valve installation no need to shut down the process or drain the oil Proven Vaisala
More informationCONTROLLERS. Chemical Injection skids. Water Quality Monitoring Systems cum dosing (WQMSD) Mobile Disinfection/Dosing systems
Chemical Injection skids CONTROLLERS Water Quality Monitoring Systems cum dosing (WQMSD) Mobile Disinfection/Dosing systems Containarised Water Treatment systems CONTROLLERS AND MEASUREMENTS TOUCH controller
More informationGRUNDFOS INSTRUCTIONS. PC Tool LC 22x. LC 220 and LC 221 controllers. Installation and operating instructions
GRUNDFOS INSTRUCTIONS PC Tool LC 22x LC 220 and LC 221 controllers Installation and operating instructions English (GB) English (GB) Installation and operating instructions Original installation and operating
More information*suitable both for membrane sensors or chlorine open cell
CTRL POOL THE SIMPLE, RELIABLE, COST EFFECTIVE SYSTEMS FOR SMALL POOLS CTRL POOL is a compact system, with single or dual controller and peristaltic dispensers all in one enclosure. CTRL POOL is extremely
More informationFlow Measurement SITRANS F C
Overview MASS 6 is based on digital signal processing technology engineered for high performance, fast flow step response, fast batching applications, high immunity against process noise, easy to install,
More informationA Guide To Using. > WebCAPS. Grundfos International Version
A Guide To Using > WebCAPS Grundfos International Version Introduction... 4 General... 4 Who should use this program?... 4 Disclaimer... 5 What's new... 6 New Products... 6 What s new in WebCAPS 2010.01?...
More informationLAKEWOOD INSTRUMENTS MODEL 1575e WATER TREATMENT CONTROLLER
LAKEWOOD INSTRUMENTS MODEL 1575e WATER TREATMENT CONTROLLER The Model 1575e uses the latest in microprocessor capability, giving the user a high level of application flexibility. A large illuminated graphics
More informationUltrasonic Flow Meter Brochure
Ultrasonic Meter Brochure Rev. 2011/06/10 www.sitelab.us.com Descriptions SL1168 Ultrasonic meter uses the latest digital technology and low-voltage broadband pulse transmission. The instrument is tolerant
More informationEL300. Multi-Channel Water Controller. Specialist Of UV Spectroscopy
EL300 Multi-Channel Water Controller Specialist Of UV Spectroscopy Crédits photos : Tethys Instruments Couverture : Sonchai Jongmeesuk / agence 123rf Page intérieur : Bagiuiani / agence 123rf > EL300 Multi-Channel
More informationControl and automatic dosing
Control and automatic dosing For public and residential pools Control Basic and Control Basic Plus Control Basic Next Optima and Optima Next dosing pumps Panels for the galvanic and amperometric control
More informationGrundfos MAGNA, GENI Module
GRUNDFOS INSTRUCTIONS Grundfos MAGNA, GENI Module Installation and operating instructions 2 Grundfos MAGNA, GENI Module Installation and operating instructions 4 3 LIMITED WARRANTY Products manufactured
More informationCapacitance level switches LS 210 LS 220
KROHNE 03/2001 7.02374.31.00 GR/PRINTO Capacitance level switches Compact switches for liquids, solids, slurry, foam and interface; outstanding performance for a low price Easy to install, no moving parts,
More informationCATALOGUE CAPACITIVE SENSORS KXS
CATALOGUE CAPACITIVE SENSORS KXS 2 For all transactions the newest version of "General Conditions of Sale and Delivery for Products and Services of the Electrical Industry ZVEI" shall apply, with the supplementary
More informationDMT345 and DMT346 Dewpoint Transmitters
DMT345 and DMT346 Dewpoint Transmitters for High Temperature Applications Features DMT345 measures humidity at temperatures up to 180 C (356 F) DMT346 measures humidity at temperatures up to 350 C (+662
More informationGRUNDFOS INSTRUCTIONS. Control MPC. Installation and operating instructions
GRUNDFOS INSTRUCTIONS Control MPC Installation and operating instructions English (GB) English (GB) Installation and operating instructions Original installation and operating instructions CONTENTS Page
More informationMPI-DN, MPI-D MULTICHANNEL ELECTRONIC RECORDER for HART or RS-485/ MODBUS RTU SENSORS
MPI-DN, MPI-D MULTICHANNEL ELECTRONIC RECORDER for HART or RS-485/ MODBUS RTU SENSORS 18 channels for HART / Modbus RTU sensors 2 digital channels 16 math channels 4 relay outputs for alarm or control
More informationTHE TECHNOLOGY BEHIND THE MEASUREMENT
THE TECHNOLOGY BEHIND THE MEASUREMENT The USCX series non-invasive flowmeters work on the transit time ultrasonic principle. This involves sending and receiving ultrasonic pulses from a pair of sensors
More informationContinuous level measurement Ultrasonic transducers
Siemens G 2013 Overview transducers use ultrasonic technology to measure level in a wide range of liquids and solids. Benefits Integral temperature compensation Low ringing effect reduces blanking distance
More informationMicroprocessor Resistivity & Conductivity Monitor/Controller EC410 / EC430. Operation Manual
Microprocessor Resistivity & Conductivity Monitor/Controller EC410 / EC430 Operation Manual INDEX 1 Specifications 2 Assembly and installation 2.1 Precautions for installation 2.2 Installation of controller
More informationHumidity transmitter for critical climate applications
Humidity transmitter for critical climate applications testo 6651 Optimum adjustment concept thanks to adjustability of the entire signal chain incl. analog adjustment Ethernet, relay and analog outputs
More informationKRAL Electronics BEM 300 and BEM 500.
KRAL Electronics BEM 300 and BEM 500. KRAL Electronics BEM 300 and BEM 500 Electronic units that are coordinated to KRAL flowmeters and their diverse applications. Coordinated to the flowmeters and their
More informationDTB-1. Digital Thermometer Battery Powered
Digital Thermometer Battery Powered Battery powered 100mm stainless steel case (IP65) Direct mount, panel mount, or surface mount Clear 6 digit alphanumeric LCD display Configured C or F High accuracy
More informationSITRANS L Level instruments
Overview Technical specifications Mode of Operation Measuring principle Ultrasonic level measurement Measuring range 0.3 to 1 m (1 to 0 ft), transducer dependent Measuring points 1 or 2 Input Analog 0
More informationClear Benefits of the KRAL Electronic.
Clear Benefits of the KRAL Electronic. Coordinated to the flowmeters and their applications. Users of conventional universal display units often cannot make use of their device s options. There is often
More informationPS-AULDP Series. Overview. Applications. Features & Benefits. Datasheet. Ultra Low Air Differential Pressure Transmitters
PS-AULDP Series Datasheet Ultra Low Air Differential Pressure Transmitters Overview The PS-AULDP Series are ultra-low-pressure transmitters. These devices can be used to measure differential pressure between
More informationFLS M9.06. ph/orp MONITOR
FLS M9.06 /ORP MONITOR Safety Instructions General Statements Do not install and service the product without following the Instruction Manual. This item is designed to be connected to other instruments
More informationFLS M9.06 PH/ORP MONITOR. safety instructions. packing List
FLS M9.06 PH/ORP MONITOR safety instructions General Statements Do not install and service the product without following the Instruction Manual. This item is designed to be connected to other instruments
More informationSignet 2552 Metal Magmeter Flow Sensors
Signet 2552 Metal Magmeter Flow s Features Test certificate included Award winning hot-tap magnetic flow sensor up to DN2550 (102 in.) Patented Magmeter technology* Operating range 0.05 to 10 m/s (0.15
More informationTransmitter / Controller Series J dtrans ph 01, Rd 01, Lf 01, Rw 01, Az 01
Transmitter / Controller Series J dtrans ph 01, Rd 01, Lf 01, Rw 01, Az 01 with C-UL-US approval PR 20004 GB ph mv ms/cm µs/cm M xcm Transmitter / Controller Series J dtrans ph 01, Rd 01, Lf 01, Rw 01,
More informationVane wheel probe BFA25 for flow measurement of gases and liquids with integrated, configurable transducer UFA in Ex-d housing
Vane wheel probe BFA25 for flow measurement of gases and liquids with egrated, configurable transducer UFA in Ex-d housing Drawing 5 Vane wheel flow probe BFA25 (Dimensions see Page 3) Measurable variables
More informationCapacitive Sensors. For Sales and Support, Contact Walker EMD Toll-free: (800) Tel: (203) Fax: (203)
Capacitive Sensors Overview cylindrical designs product family CFAM 12 CFAM 18 CFBM 20 CFAM 30 CFAK 12 CFAK 18 CFAK 30 shielded n n n n n n n Overview 4 mm 8 mm 10 mm 15 mm 4 mm 8 mm 15 mm housing length
More informationFusion of electronic pressure sensor and analogue display.
Fusion of electronic pressure sensor and analogue display. Pressure sensors www.ifm.com/gb/pg fluid sensors and diagnostic systems position sensors and object recognition bus, identification and control
More informationIKA Crushing 76 Dispersers (batch operation)
76 Dispersers (batch operation) Dispersers (batch operation) 77 T 18 basic ULTRA-TURRAX Competitively priced dispersing instrument for volumes of 1 to 1.500 ml (H2O). A wide speed range allows you to work
More informationSono-Trak Transit Time Clamp-on Ultrasonic Flow Meter
A trademark of Spirax Sarco, Inc. Sono-Trak Transit Time Clamp-on Ultrasonic Flow Meter Description Engineered for performance excellence, the Sono-Trak Transit Time ultrasonic meter combines non-invasive,
More informationECHOMAX XPS-10 ULTRASONIC TRANSDUCER
Datasheet ECHOMX XPS-10 ULTRSONIC TRNSDUCER Supplied by.com Call us on + (0)118 916 920 Email info@27able.com Overview transducers use ultrasonic technology to measure level in a wide range of liquids
More informationPlug & Play Analytical Solutions Making Basic Measurements Easy
easy Line easy Line Plug & Play analytics Complete solution package Easy commissioning & installation Plug & Play Analytical Solutions Making Basic Measurements Easy easy Line A Complete Solution Package
More informationTemperature sensors and accessories for heat and cooling measurement points
Temperature sensors and accessories for heat and cooling measurement points Applications Temperature sensors are metrological components for heat or cold measuring points. They are used in pairs and measure
More information