SERIES VAC PANEL MOUNT

Size: px
Start display at page:

Download "SERIES VAC PANEL MOUNT"

Transcription

1 SERIES VAC PANEL MOUNT Features Ratings from A to VAC SCR output for heavy industrial loads Zero voltage or instantaneous turn-on outputs UL/CSA/VDE Approved, CE Compliant to EN69- Improved SEMS screw and washer Redesigned housing with anti-rotation barriers AC or DC control Direct bond copper substrate EMC compliant to Level Direct power lead frame Epoxy free design PRODUCT SELECTION Control Voltage - VDC 9-8 VAC 8-6 VAC A A A 7A 9A A A D A AE D A AE D A AE D7 A7 A7E D9 A9 A9E D A AE D A AE ORDERING OPTIONS A E K P G S H - Control Voltage A: 9-8 VAC D: - VDC AxxxxE: 8-6 VAC Operating Voltage : VAC Rated Load Current : Amps : Amps : Amps 7: 7 Amps 9: 9 Amps : Amps : Amps Termination Blank: Screw F: Quick Connect (Up to Amps only) () K: Hex standoffs () Overvoltage Protection P: Included () Input Status LED G: Included Snubber S: Included Thermal Pad H: Included Switching Type Blank: Zero Voltage Turn-On -: Instantaneous Turn-On () Required for valid part number For options only and not required for valid part number Note: Not all part number combinations are available. Contact Crydom Technical support for information on the availability of a specific part number. Page

2 SPECIFICATIONS () Description Operating Voltage (7-Hz) [Vrms] (6) Transient Overvoltage [Vpk] Maximum Off-State Leakage Rated Voltage [marms] (7) Minimum Off-State Maximum Rated Voltage [V/µsec] Maximum Load Current [Arms] ()(8) Minimum Load Current [marms] Maximum Cycle Surge Current (/6Hz) [Apk] Maximum On-State Voltage Rated Current [Vrms] Thermal Resistance Junction to Case (Rjc) [ C/W] Maximum / Cycle I² t for Fusing (/6Hz) [A² sec] Minimum Power Factor (at Maximum Load) () A A A 7A 9A A A /.. 66/6 9/..8 8/9 97/6.. 77/6 7 9/.. / 9 /..7 66/976 /.. 9/98 67/7.. 9/79 SPECIFICATIONS () Description Dxx Control Voltage Range Maximum Reverse Voltage Minimum Turn-On Voltage Must Turn-Off Voltage Minimum Input Current [ma] Maximum Input Current [ma] Nominal Input Impedance [Ohms] Maximum Turn-On Time [msec] Maximum Turn-Off Time [msec] - VDC - VDC. VDC (9). VDC 7 / Cycle () / Cycle Axx AxxE 9-8 Vrms 9 Vrms Vrms Current Regulated 8-6 Vrms 8 Vrms Vrms 6 GENERAL SPECIFICATIONS () Description Parameters Dielectric Strength, Input/Output/Base (/6Hz) Minimum Insulation Resistance (@ VDC) Vrms 9 Ohm 8 pf - to 8 C - to C.6 oz (7.9g) UL 9 V- Aluminum - / / /.-. w/ K option 8- /.9-. #6- UNC / #8- UNC 9% non-condensing w/ G option (green),6, hours (,8 years) 7,,76 hours (8 years) Maximum Capacitance, Input/Output Ambient Operating Temperature Range Ambient Storage Temperature Range Weight (typical) Housing Material Baseplate Material Input Terminal Screw Torque Range (in-lb/nm) Load Terminal Screw Torque Range (in-lb/nm) SSR Screw Torque Range (in-lb/nm) Input/Load Terminal Screw Torque Range (in-lb/nm) () Input/Output Terminal Screw Thread Size Humidity per IEC LED Input Status Indicator MTBF (Mean Time Between Failures) at C ambient temperature () MTBF (Mean Time Between Failures) at 6 C ambient temperature () WIRING DIAGRAM AC ( ) Terminals Input Output Wire Size (Solid / Stranded) Wire Pull-Out Strength (lb)[n] AWG (. mm) /. [minimum] [.] x AWG (. mm) /. [maximum] 9 [] AWG ( mm) / 8 [minimum] [] mm) [9] x AWG (. /. x 8 AWG (8. mm) / 8. [maximum] 9 [] Input Current (ma) Load () ( ) Input Current vs Input Voltage Standard Regulated DC Input Recommended Wire Sizes V DC Input Voltage ( / ) (+ / ) Page

3 EQUIVALENT CIRCUIT BLOCK DIAGRAMS Diagram: Series AC control Diagram: Series DC control AC AC AC/DC Converter Current Limiter -DC AC () () () Trigger Circuit Trigger Circuit () () AC AC +DC () AC Current Limiter MECHANICAL SPECIFICATIONS () Tolerances: ±. in / mm All dimensions are in: inches [millimeters] Hex Standoff Termination ( K Option) () Screw Termination. [7.9].9 [.].88 [7.6]. [7.9].9 [.].89 [.6].9 [.9]. [7.].7 [.].88 [7.6].8 [.].9 [.].88 [7.6] Faston Terminal(6). x.. [.6].7 [.] ( places). [.] Quick Connect Termination ( F Option) - Up to Amp (). [.].88 [7.6] ( places).9 [.]. [.6].7 [.]. [.8]. [.]. [.] Faston Terminal(6).87 x. ( places) ( places). [7.].7 [.] Faston Terminal(6). x..8 [.].6 [6.].9 [.9] ( places).9 [.6] ( places) Quick Connect Termination ( F Option) - Up to Amp ().9 [.9].7 [.].7 [.]. [7.].7 [.]. [.]. [.]. [6.].9 [.9]. [7.].7 [.] Faston Terminal(6).87 x. ( places). [.8] Page

4 SURGE CURRENT INFORMATION A A A.. 9 A A A A Non repetitive peak surge current at Tj initial ºC. Page

5 THERMAL DERATE INFORMATION A ºC/W A ºC/W.ºC/W No Heatsink A.7ºC/W ºC/W.ºC/W ºC/W ºC/W 8 A 9 A ºC/W.ºC/W 8 ºC/W ºC/W.ºC/W.7ºC/W ºC/W.ºC/W ºC/W ºC/W 8.7ºC/W ºC/W A ºC/W A ºC/W.7ºC/W ºC/W Page

6 AGENCY APPROVALS AND CERTIFICATIONS EN69 : Meets the requirements of sections.:,7:.9:...:.:.:.7: Designed in accordance with the requirements of IEC 6 IEC -- : Electrostatic Discharge Level IEC -- : Electrically Fast Transients Level IEC -- : Electrical Surges Level IEC : Vibration.mm and.7 mm Amplitude over - Hz IEC : Shock Resistance g/ms E699 LR8689 UG ACCESORIES New Accessories! Recommended Accessories Protective Cover & Hardware Kits Protective Cover Part number: KS Clear plastic cover compatible with all new S designs. Safety covers provide added protection from electric shock when installing or checking equipment. Cover Hardware Kit KS HK HSDR. TRM HSP- HK HS / HSDR. TRM6 HSP- HS. HS / HSDR. HS / HSDR. HS7.7 HS / HSDR. HS / HSDR. HS / HSDR. HS. HS7.7 HS7.7 Hardware Kit Part number: HK Bag with square brass accessories and screw 8- x /8 for output. Used to mount TMR lug terminals. Heat Sink Part No. Thermal Resistance Lug Terminal Thermal Pad [ºC/W] HS HS.6 HS. GENERAL NOTES () Single pair (up to A) Double pair* (up to A). *Caution: User must connect both pairs. () Option K is designed and tested for use with printed circuit boards or ring/fork terminals having a thickness between. and.9 inches (.79 to.6 mm), and loads rated up to Amps. For higher load currents, the K standoff temperature must not exceed C. For additional application assistance please contact Crydom Technical Support. () Output will self trigger between -Vpk, Min. power factor.7 or higher, not suitable for capacitive loads. () Instantaneous turn-on version is not recomended for capacitive loads. Use zero turn-on only. () All parameters at C unless otherwise specified. (6) For S option, operating voltage frequency is 7-6Hz. (7) For parts with option S maximum leakage current is ma. (8) Heat sinking required, see derating curves. (9) Increase minimum voltage by V for operations from - to - C. () Turn-on time for instantaneous turn-on versions is. msec (DC control Models). () All parameters at % power rating and % duty cycle (contact Crydom tech support for detailed report). () Load can be wired to either SSR output terminal or. () Elective Input Status LED, G option () Elective Overvoltage Protection, P option. () Elective Internal Snubber, S option. (6) Mechanical dimensions vary from G models. For additional information or specific questions, contact Crydom Technical Support. Page 6

7 WARNINGS RISK OF MATERIAL DAMAGE AND HOT ENCLOSURE The product s side panels may be hot, allow the product to cool before touching Follow proper mounting instructions including torque values Do not allow liquids or foreign objects to enter this product Failure to follow these instructions can result in serious injury, or equipment damage. HAZARD OF ELECTRIC SHOCK, EXPLOSION OR ARCH FLASH Disconnect all power before installing or working with this equipment Verify all connections and replace all covers before turning on power Failure to follow these instructions will result in death or serious injury Page 7 Sensata Technologies, Inc. ( Sensata ) data sheets are solely intended to assist designers ( Buyers ) who are developing systems that incorporate Sensata products (also referred to herein as components ). Buyer understands and agrees that Buyer remains responsible for using its independent analysis, evaluation and judgment in designing Buyer s systems and products. Sensata data sheets have been created using standard laboratory conditions and engineering practices. Sensata has not conducted any testing other than that specifically described in the published documentation for a particular data sheet. Sensata may make corrections, enhancements, improvements and other changes to its data sheets or components without notice. Buyers are authorized to use Sensata data sheets with the Sensata component(s) identified in each particular data sheet. HOWEVER, NO OTHER LICENSE, EXPRESS OR IMPLIED, BY ESTOPPEL OR OTHERWISE TO ANY OTHER SENSATA INTELLECTUAL PROPERTY RIGHT, AND NO LICENSE TO ANY THIRD PARTY TECHNOLOGY OR INTELLECTUAL PROPERTY RIGHT, IS GRANTED HEREIN. SENSATA DATA SHEETS ARE PROVIDED AS IS. SENSATA MAKES NO WARRANTIES OR REPRESENTATIONS WITH REGARD TO THE DATA SHEETS OR USE OF THE DATA SHEETS, EXPRESS, IMPLIED OR STATUTORY, INCLUDING ACCURACY OR COMPLETENESS. SENSATA DISCLAIMS ANY WARRANTY OF TITLE AND ANY IMPLIED WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, QUIET ENJOYMENT, QUIET POSSESSION, AND NON-INFRINGEMENT OF ANY THIRD PARTY INTELLECTUAL PROPERTY RIGHTS WITH REGARD TO SENSATA DATA SHEETS OR USE THEREOF. All products are sold subject to Sensata s terms and conditions of sale supplied at SENSATA ASSUMES NO LIABILITY FOR APPLICATIONS ASSISTANCE OR THE DESIGN OF BUYERS PRODUCTS. BUYER ACKNOWLEDGES AND AGREES THAT IT IS SOLELY RESPONSIBLE FOR COMPLIANCE WITH ALL LEGAL, REGULATORY AND SAFETY-RELATED REQUIREMENTS CONCERNING ITS PRODUCTS, AND ANY USE OF SENSATA COMPONENTS IN ITS APPLICATIONS, NOTWITHSTANDING ANY APPLICATIONS-RELATED INFORMATION OR SUPPORT THAT MAY BE PROVIDED BY SENSATA. Mailing Address: Sensata Technologies, Inc., 9 Pleasant Street, Attleboro, MA 7, USA. Rev. //8 ECN 9 FDE-7- Rev. B CONTACT US Americas + (877) Option sales.crydom@sensata.com Europe, Middle East & Africa + () 67 ssr-info.eu@sensata.com Asia Pacific sales.isasia@list.sensata.com China +86 () 6 Japan +8 () Korea +8 () 6 India +9 (8) Rest of Asia +886 () 766 ext 88

1-DC SERIES PANEL MOUNT

1-DC SERIES PANEL MOUNT 1DC SERIES PANEL MOUNT Features Ratings from 6 A to 1 A @ 1 DC Mosfet Output UL Approved, CE Compliant to EN6951 Improved SEMS screw and washer Redesigned housing with antirotation barriers DC control

More information

PMP SERIES PROPORTIONAL CONTROL SOLID STATE RELAYS Introduction

PMP SERIES PROPORTIONAL CONTROL SOLID STATE RELAYS Introduction PMP SERIES PROPORTIONAL CONTROL SOLID STATE RELAYS Introduction The PMP Series of micro-controller based Single-Phase Proportional Control SSRs are designed to offer precise control of the power delivered

More information

Introduction. Features. Applications DR45 SERIES AC SINGLE PHASE OUTPUT DIN RAIL MOUNT SSRS PRODUCT SELECTION

Introduction. Features. Applications DR45 SERIES AC SINGLE PHASE OUTPUT DIN RAIL MOUNT SSRS PRODUCT SELECTION DR45 SERIES AC SINGLE PHASE OUTPUT DIN RAIL MOUNT SSRS Introduction The DR45 is a powerful and compact solid state relay in a DIN rail 45mm wide package with an output rating up to 6 Amps @ 4 C offering

More information

MODEL NUMBERS OUTPUT SPECIFICATIONS 1 Zero Voltage and Random Turn-On Switching Panel Mount 600V Transient Capability Internal Snubber 110 & 125A Mode

MODEL NUMBERS OUTPUT SPECIFICATIONS 1 Zero Voltage and Random Turn-On Switching Panel Mount 600V Transient Capability Internal Snubber 110 & 125A Mode MODEL NUMBERS OUTPUT SPECIFICATIONS 1 Zero Voltage and Random Turn-On Switching Panel Mount 600V Transient Capability Internal Snubber 110 & 125A Models Available Integrated Overvoltage Protection by Automatic

More information

MHK5 SERIES PROFINET ABSOLUTE MULTI -TURN ENCODER

MHK5 SERIES PROFINET ABSOLUTE MULTI -TURN ENCODER MHK5 SERIES PROFINET ABSOLUTE MULTI -TURN ENCODER Features Robust and compact design Blind shaft version. 15mm standard ID with options down to 6mm ID Precision ball bearings with sealing flange High temperature

More information

Zelio Relay - Solid State Relays

Zelio Relay - Solid State Relays Selection guide Applications Panel mounted PF--Q Contact type N/O SPST contact Control voltage ranges a V c SCR output : V Mosfet output :. V Operating voltages a V, V, V c V Type of switching a Zero voltage

More information

DRMS SERIES DIN RAIL MOUNT HYBRID MOTOR STARTERS

DRMS SERIES DIN RAIL MOUNT HYBRID MOTOR STARTERS DRMS SERIES DIN RAIL MOUNT HYBRID MOTOR STARTERS DRMS Series Hybrid Motor Starters are intelligent and convenient solutions for controlling 3-phase asynchronous motors. These compact devices can provide

More information

G3NE. Model Number Structure. Solid State Relays. Model Number Legend. Compact, Low-cost, SSR Switching 5 to 20 A

G3NE. Model Number Structure. Solid State Relays. Model Number Legend. Compact, Low-cost, SSR Switching 5 to 20 A Solid State Relays CSM DS_E_4_1 Compact, Low-cost, SSR Switching 5 to 20 A Wide load voltage range: 75 to 264 VAC. Both 100-V and 200-V loads can be handled with the same model. Dedicated, compact aluminum

More information

717 SERIES SOCKET FOR QFN/LGA PACKAGES

717 SERIES SOCKET FOR QFN/LGA PACKAGES 717 SERIES SOCKET FOR QFN/LGA PACKAGES Features Clamshell design, compression surface mount Spring and probe contact Pointed probe maintains continuous contact to PCB Spring loaded pressure pad and locater

More information

ACW4 SSI SSI ABSOLUTE SINGLE TURN MODULAR

ACW4 SSI SSI ABSOLUTE SINGLE TURN MODULAR ACW4 SSI SSI ABSOLUTE SINGLE TURN MODULAR Features With its two-part design, the ACW4 absolute single-turn offers maximum flexibility for installation Rugged and excellent resistance to shock and vibration

More information

Relays & Sockets. RSC Series. RSC Series Solid State Relays. Part Number Selection Specifications

Relays & Sockets. RSC Series. RSC Series Solid State Relays. Part Number Selection Specifications RSC Series RSC Series Solid State Relays Key features of the RSC series include: Slim design allows for DIN rail or panel mounting Built-in heat sink maximizes current output capability Epoxy-free design

More information

Model Number Structure

Model Number Structure Solid State Relays CSM DS_E_3_1 Compact, Low-cost, SSR Switching 5 to 20 A Wide load voltage range: 75 to 264 VAC. Both 100-V and 200-V loads can be handled with the same model. Dedicated, compact aluminum

More information

HS35 ABSOLUTE ENCODER

HS35 ABSOLUTE ENCODER HS35 ABSOLUTE ENCODER Product Description Built on the same rugged design as the incremental model, the HS35 Absolute Encoder is available with various output options including Gray Code and Natural Binary.

More information

Series LS. 30A to 600 Vac SIP Package DC control LS 24 D 16 C. Figure 1 LS relays; dimensions in inches (mm) (See Figure 12 for LS with HS1)

Series LS. 30A to 600 Vac SIP Package DC control LS 24 D 16 C. Figure 1 LS relays; dimensions in inches (mm) (See Figure 12 for LS with HS1) 3A to 6 Vac SIP Package DC control Part Number LSD16C LSD1C LS6DC LSD7C LS6D7C LS6D3C Description 16A, Vac 1A, Vac A, 6 Vac 7A, Vac 7A, 6 Vac 3A, 6 Vac Part Number Explanation LS D 16 C NOTES 1) Line Voltage

More information

NEW Series SSH Output to 75A, 510 Vac with Diagnostics High Industrial Performance (HIPpak) Solid-State Relays

NEW Series SSH Output to 75A, 510 Vac with Diagnostics High Industrial Performance (HIPpak) Solid-State Relays FEATURES/BENEFITS Zero-cross models with system diagnostics Very low zero-cross turn-on voltage Input and output protection and control LED standard IP20 protection by flaps on terminals With double removable

More information

DSM5H & DSO5H MODELS SIL3 PLe INCREMENTAL ENCODERS

DSM5H & DSO5H MODELS SIL3 PLe INCREMENTAL ENCODERS & MODELS SIL3 PLe INCREMENTAL ENCODERS Features Usable up to SIL3 and Cat.4 / PLe according to IEC 61508 / EN ISO 13849 Suitable for safe motor feedback according to IEC 61800-5-2 Robustness and excellent

More information

G3B/G3BD. Model Number Structure. Ordering Information. Solid State Relays Model Number Legend. List of Models

G3B/G3BD. Model Number Structure. Ordering Information. Solid State Relays Model Number Legend. List of Models Solid State Relays G3@-VD CSM_G3B_G3BD_DS_E_5_1 International Standards for G3B Series, Same Profile as MK Power Relays Shape-compatible with mechanical relays. Certified by UL, CSA, and VDE (models numbers

More information

Solid State Relays with Failure Detection Function

Solid State Relays with Failure Detection Function Solid State Relays with Failure Detection Function CSM DS_E_2_1 Refer to Safety Precautions for All Solid State Relays. Detects failures in SSR used for heater temperature control and simultaneously outputs

More information

Model Number Structure

Model Number Structure Solid State Relays CSM DS_E_2_1 I/O SSRs That Mount to OMRON s G7TC I/O Block Input and output modules are available in wide variety. Snaps easily into P7TF I/O Terminals and can be used together with

More information

Series SD. Series Switch Type 2 Feature 3 Line Voltage 1 Output Current - Amps. Dual Output to 50A 600 Vac DC Control Solid-State Relay

Series SD. Series Switch Type 2 Feature 3 Line Voltage 1 Output Current - Amps. Dual Output to 50A 600 Vac DC Control Solid-State Relay Dual Output to 5A Vac FEATURES/BENEFITS The Series SD dual-phase relays are designed for all types of loads. The design incorporates two relays in a single package. The relays utilize optical isolation

More information

SM320A~SM3200A SCHOTTKY DIODE REVERSE VOLTAGE 20 TO 200V FORWARD CURRENT 3.0A

SM320A~SM3200A SCHOTTKY DIODE REVERSE VOLTAGE 20 TO 200V FORWARD CURRENT 3.0A 320A~3200A DESCRIPTION The 320A~3200A are available in A Package. ORDERING INFORMATION Package Type Part Number 320A 340A 360A 380A A 3100A 3120A 3150A 3200A Note 5,000pcs/Reel AiT provides all RoHS Compliant

More information

(75 to 264 VAC) 12 VDC 24 VDC No 5 VDC G3MC-202PL 12 VDC 24 VDC

(75 to 264 VAC) 12 VDC 24 VDC No 5 VDC G3MC-202PL 12 VDC 24 VDC Solid State Relay G3MC Compact, Thin-profile, Low-cost SSR with Reinforced Insulation Small bottom surface area (approx. 80% of the conventional G3MB s), ideal for close PCB mounting. DC input and AC output

More information

MVAD040 Series 40W 2" x 4" AC-DC Power Supply Converter

MVAD040 Series 40W 2 x 4 AC-DC Power Supply Converter www.murata-ps.com MVAD040 Series DESCRIPTION The MVAD040 series switching power supplies utilize advanced component and circuit technologies to deliver high effi ciency. Designed for Medical, Telecom,

More information

Series AMEPR60C-AZ up to 5A AC-DC / DC-DC LED Driver / Converter

Series AMEPR60C-AZ up to 5A AC-DC / DC-DC LED Driver / Converter Click on Series name for product info on aimtec.com Series AMEPRC-AZ Models Single output Model Max Output Power (W) 1 FEATURES: Output Voltage Range (V) 3 Output Current 3 AMEPRC-120AZ 36-0 - 1.20 AMEPRC-361AZ

More information

Power Supply. Users Guide PRODUCT MANUAL. WESTELL.COM Westell Technologies MNL rd

Power Supply. Users Guide PRODUCT MANUAL. WESTELL.COM Westell Technologies MNL rd PRODUCT MANUAL Power Supply Westell Technologies. 960-1152-MNL rd DISCLAIMER All information and statements contained herein are accurate to the best of Westell Technologies knowledge. Westell Technologies

More information

G3PC. Model Number Structure. Solid State Relays with Failure Detection Function. Model Number Legend

G3PC. Model Number Structure. Solid State Relays with Failure Detection Function. Model Number Legend Solid State Relays with Failure Detection Function G3PC Refer to Warranty and Application Considerations (page 1), Safety Precautions (page 4), and Technical and Safety Information (page 6). Detects failures

More information

Series AMER120-AZ up to 5A AC-DC / DC-DC LED Driver / Converter

Series AMER120-AZ up to 5A AC-DC / DC-DC LED Driver / Converter Click on Series name for product info on aimtec.com Series AMER120-AZ FEATURES: AC-DC Constant Current or Constant Over Current Protection Voltage LED Driver Short Circuit Protection Input range 90-305VAC/47-440Hz

More information

209/219/229/249/279 SERIES HYDRAULIC MAGNETIC CIRCUIT PROTECTORS

209/219/229/249/279 SERIES HYDRAULIC MAGNETIC CIRCUIT PROTECTORS 209/219/229/249/279 SERIES HYDRAULIC MAGNETIC CIRCUIT PROTECTORS Introduction The 209, E-Frame circuit breaker combines power switching with accurate, reliable circuit protection in a compact single or

More information

These power supplies are ideal for telecom, datacom, industrial equipment and other applications.

These power supplies are ideal for telecom, datacom, industrial equipment and other applications. The ABC60 Series of AC-DC open-frame power supplies, with its wide universal 90-264 VAC input range and high power density, is available at 60 W of output power and a variety of single and multiple output

More information

G3NE. Ordering Information. Solid State Relay. Compact, Low-cost, SSR Switching 5to20A J ACCESSORIES (ORDER SEPARATELY) Solid State Relay G3NE

G3NE. Ordering Information. Solid State Relay. Compact, Low-cost, SSR Switching 5to20A J ACCESSORIES (ORDER SEPARATELY) Solid State Relay G3NE Solid State Relay G3NE Compact, Low-cost, SSR Switching 5to20A D Wide load voltage range: 75 to 264 VAC. D Dedicated, compact aluminum PCB and power elements used. D Built-in varistor effectively absorbs

More information

Model Number Structure

Model Number Structure Solid State Relays with Failure Detection Function G3PC CSM_G3PC_DS_E_1_1 Refer to Safety Precautions for All Solid State Relays. Detects failures in SSR used for heater temperature control and simultaneously

More information

Model Number Structure

Model Number Structure Solid State Relays with Failure Detection Function Refer to Safety Precautions for All Solid State Relays. Detects failures in SSR used for heater temperature control and simultaneously outputs alarm signal.

More information

Model Number Structure

Model Number Structure Solid State Relays G3@-VD CSM_G3F_G3FD_DS_E_4_2 International Standards for G3F Series, Same Profile as MY Power Relays Shape-compatible with mechanical relays. Certified by UL, CSA, and VDE (model numbers

More information

Switch Mode Power Supply S8VT 120/240/480/960 W Models

Switch Mode Power Supply S8VT 120/240/480/960 W Models Switch Mode Power Supply 120/240/480/960 W Models Natural Cooling Three-phase Power Supply Range from 5A up to 40A with Output Voltage of 24VDC 3 phase 400 to 500 VAC 5, 10, 20 and 40 A; 24 VDC output

More information

4 x 2 x 0.75 Inches Form factor. 180 Watts with Forced Air Cooling. Approved to EN/IEC Efficiencies up to 92% Standby Power < 0.

4 x 2 x 0.75 Inches Form factor. 180 Watts with Forced Air Cooling. Approved to EN/IEC Efficiencies up to 92% Standby Power < 0. The MBC180 Series of ultra low open frame medical power supplies feature a wide universal AC input range of 85 V 264 VAC, offering output power 180 W with 13 CFM of forced air cooling or up to 120 W with

More information

DC-DC CONVERTERS SINGLE OUTPUT, 60 WATTS EXTREMELY WIDE 12:1 INPUT VOLTAGE RANGE: 9-75VDC, VDC RAILWAY APPLICATIONS

DC-DC CONVERTERS SINGLE OUTPUT, 60 WATTS EXTREMELY WIDE 12:1 INPUT VOLTAGE RANGE: 9-75VDC, VDC RAILWAY APPLICATIONS DC-DC CONVERTERS SINGLE OUTPUT, 60 WATTS EXTREMELY WIDE 12:1 INPUT VOLTAGE RANGE: 9-75VDC, 14-160VDC RAILWAY APPLICATIONS FEATURES 60 Watt Output Power Extremely Wide 12:1 Input range: 9-75, 14-160 Output

More information

Model Number Structure

Model Number Structure Solid State Relays with Failure Detection Function G3PC Detects failures in SSR used for heater temperature control and simultaneously outputs alarm signal. This SSR supports the safe design of heater

More information

TEP 100WIR Series, 100 Watt

TEP 100WIR Series, 100 Watt TEP 100WIR Series, 100 Watt Features Compact metal package Ultra wide 4:1 input voltage ranges 8.5 36, 16.5 75, 43 160 VDC EN 50155 approval for railway applications Very high efficiency up to 92% No minimum

More information

Voltage Current Front-mounting bracket

Voltage Current Front-mounting bracket Switching Power Supply S8PS Compact DIN-Rail Mounting Industrial Power Supplies with Capacities Up to 600 W Models range from 0 W to 600 W. Universal input: voltage range 0 to 240 VAC. Power Factor Correction

More information

G3H/G3HD. Model Number Structure. Solid State Relays Model Number Legend

G3H/G3HD. Model Number Structure. Solid State Relays Model Number Legend Solid State Relays G@-VD CSM_GH_GHD_DS_E_6_ New Models with International Standards Added to GH Series (-VD in model number). Same Profile as LY and LY Bi-power Relays Certified by UL, CSA, and VDE (models

More information

Ordering Information. I/O Relay G7T. Model Number Legend Slim-styled I/O Relay Saves Space in Panel

Ordering Information. I/O Relay G7T. Model Number Legend Slim-styled I/O Relay Saves Space in Panel I/O Relay CSM DS_E_4_4 Slim-styled I/O Relay Saves Space in Panel SPST-NO, SPST-NC, and SPDT contact forms available for output (SPST-NO only for input). Ultra-slim housing measuring 29 (W) x 0 (D) x 2

More information

Solid State Relays Industrial, 1-Phase ZS (IO) w. LED Types RAM1A, RAM1B

Solid State Relays Industrial, 1-Phase ZS (IO) w. LED Types RAM1A, RAM1B Solid State Relays Industrial, 1-Phase ZS (IO) w. LED Types RAM1A, RAM1B Zero switching (RAM1A) or instant-on switching (RAM1B) AC Solid State Relay Direct copper bonding (DCB) technology LED indication

More information

G3F/G3FD. Model Number Structure. Solid State Relays Model Number Legend

G3F/G3FD. Model Number Structure. Solid State Relays Model Number Legend Solid State Relays G3@-VD CSM_G3F_G3FD_DS_E_5_3 International Standards for G3F Series, Same Profile as MY Power Relays Reduces wiring work by 60% when combined with the PFY-08- PU Push-In Plus Socket

More information

ABL1RPM24100 regulated SMPS - single phase V input - 24 V output W

ABL1RPM24100 regulated SMPS - single phase V input - 24 V output W Characteristics regulated SMPS - single phase - 100..240 V input - 24 V output - 240 W Complementary Input voltage limits Network frequency limits Inrush current Main Range of product Product or component

More information

General Specifications. P2-8AD4DA-2 Analog Input/Output

General Specifications. P2-8AD4DA-2 Analog Input/Output General Specifications Operating Temperature Storage Temperature Humidity Environmental Air Vibration Shock Field to Logic Side Isolation Insulation Resistance Heat Dissipation 1.95W º to 6ºC (32º to 14ºF)

More information

RE7RB13MW adjustable off-delay timing relay s V AC DC - 2OC

RE7RB13MW adjustable off-delay timing relay s V AC DC - 2OC Characteristics adjustable off-delay timing relay - 0.05..1 s - 240 V AC DC - 2OC Main Range of product Product or component type Contacts type and composition Component name Time delay type Time delay

More information

P2-04AD Analog Input. Removable Terminal Block Specifications

P2-04AD Analog Input. Removable Terminal Block Specifications WARNING: To minimize the risk of potential safety problems, you should follow all applicable local and national codes that regulate the installation and operation of your equipment. These codes vary from

More information

Series AME25-JZ 25 Watt AC-DC / DC-DC Converter

Series AME25-JZ 25 Watt AC-DC / DC-DC Converter FEATURES: Click on Series name for product info on aimtec.com Series AME-JZ I/O Isolation 000VAC Low Ripple and Noise Operating Temp: -0 C to +70 C Over Voltage Protection Over current Protection Up to

More information

ABL1REM24100 regulated SMPS - single phase V input - 24 V output W

ABL1REM24100 regulated SMPS - single phase V input - 24 V output W Characteristics regulated SMPS - single phase - 100..240 V input - 24 V output - 240 W Complementary Input voltage limits Network frequency limits Inrush current Main Range of product Product or component

More information

Series AMEL10-MJZ 10 Watt AC-DC / DC-DC Converter

Series AMEL10-MJZ 10 Watt AC-DC / DC-DC Converter Click on Series name for product info on aimtec.com Models Single output Model Input Voltage (VAC/Hz) FEATURES: Input Voltage (VDC) Max Output wattage (W) Output Voltage (V) Output Current max (A) Maximum

More information

Rhino Buffer Module PSM24-BFM600S. Operating Instructions

Rhino Buffer Module PSM24-BFM600S. Operating Instructions Rhino Buffer Module PSM24-BFM600S Operating Instructions RHINO BUFFER MODULE PSM24-BFM600S Description The PSM24-BFM600S Buffer Module will hold the output voltage of a 24 VDC power supply after brownouts

More information

Ordering Information. I/O Relay G7T. Model Number Legend Slim-styled I/O Relay Saves Space in Panel

Ordering Information. I/O Relay G7T. Model Number Legend Slim-styled I/O Relay Saves Space in Panel I/O Relay CSM DS_E_2_ Slim-styled I/O Relay Saves Space in Panel SPST-NO, SPST-NC, and SPDT contact forms available for output (SPST-NO only for input). Ultra-slim housing measuring 29 (W) x 0 (D) x 2

More information

Ordering Information. Three-phase Input Switch Mode Power Supply S8VT S8VT. Model Number Legend

Ordering Information. Three-phase Input Switch Mode Power Supply S8VT S8VT. Model Number Legend Three-phase Input Switch Mode Power Supply S8VT DIN-rail mounting, Power Supply with a range of 5 A to 40 A output current 3 phase 400 to 500 VAC 5, 10, 20 and 40 A; 24 VDC output Higher stability, lower

More information

P2-04DA Analog Output. Removable Terminal Block Specifications

P2-04DA Analog Output. Removable Terminal Block Specifications WARNING: To minimize the risk of potential safety problems, you should follow all applicable local and national codes that regulate the installation and operation of your equipment. These codes vary from

More information

Solid State Relay KSI240 Series 1-Phase AC Output

Solid State Relay KSI240 Series 1-Phase AC Output Solid State Relay KSI24 1-Phase AC Output Zero switching or instant-on Ratings from 1A to 1A @ 48-28VAC SCR output for heavy industrial loads AC or DC input DBC substrate for superior thermal performance

More information

BMX DDM Mixed Relay Input/Output module

BMX DDM Mixed Relay Input/Output module Modicon M340 Using Unity Pro BMX DDM 16025 35012474 07/2012 BMX DDM 16025 Mixed Relay Input/Output module 22 Subject of this Section This section presents the BMX DDM 16025 module, its characteristics,

More information

E2EY. A Proximity Sensor for Aluminum, Brass and Other Non-ferrous Metals. Iron Is Not Detected. Aluminum-detecting Proximity Sensor

E2EY. A Proximity Sensor for Aluminum, Brass and Other Non-ferrous Metals. Iron Is Not Detected. Aluminum-detecting Proximity Sensor Aluminum-detecting Proximity Sensor EEY CSM_EEY_DS_E_5_1 A Proximity Sensor for Aluminum, Brass and Other Non-ferrous Metals. Iron Is Not Detected. Non-ferrous metals, such as aluminum and brass, are detected.

More information

TEP160-WIRCM SERIES 160 Watt High Density Brick DC-DC Converter Measures: 2.40 x 2.28 x 0.50

TEP160-WIRCM SERIES 160 Watt High Density Brick DC-DC Converter Measures: 2.40 x 2.28 x 0.50 Features Compact metal package Ultra wide 4:1 input voltage ranges 8.5 36, 16.5 75, 43 160 VDC EN 50155 approval for railway applications Very high efficiency up to 91% No minimum load Soft start Ajustable

More information

TEP 75WI Series, 75 Watt

TEP 75WI Series, 75 Watt TEP 75WI Series, 75 Watt Features UL 60950-1 Rugged, compact metal case Screw terminal adaptor available for easy connection EN 50155 approval for railway applications Optional DIN-rail mounting kit Ultra

More information

S8VE (60/90/120/180/240-W Models)

S8VE (60/90/120/180/240-W Models) Switch Mode Power Supply S8VE (60/90/120/180/240-W Models) CSM_S8VE_DS_E_1_1 60/90/120/180/240-W Models Improved Versions of Standard-type Power Supplies without Indication Monitor. Safety standards: UL508/60950-1,

More information

Mini Digital Multimeter

Mini Digital Multimeter User's Guide Mini Digital Multimeter Model MN15 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Back to the Extech MN15/MN16 Series

More information

ABL1REM Main. Rated power in W. Power supply output current V. <= 100 Aat 230 V AC. 2.5 Aat 240 V

ABL1REM Main. Rated power in W. Power supply output current V. <= 100 Aat 230 V AC. 2.5 Aat 240 V Product datasheet Characteristics ABL1REM24062 Complementary Input voltage limits Network frequency Inrush current Main Cos phi 0.65 Range of product Product or component type Power supply type Rated power

More information

S82S (3/7.5-W Models)

S82S (3/7.5-W Models) Switch Mode Power Supply (3/7.5-W Models) CSM DS_E_4_3 Miniature DIN Rail Mounting DC-DC Power Supplies 65 mm depth enables mounting onto control panels with 100 mm depth. Inputs: 10.2 to 27.6 VDC (DC

More information

ABL1REM24025 regulated SMPS - single phase V input - 24 V output - 60 W

ABL1REM24025 regulated SMPS - single phase V input - 24 V output - 60 W Characteristics regulated SMPS - single phase - 100..240 V input - 24 V output - 60 W Main Range of product Product or component type Power supply type Rated power in W Input voltage Output voltage Power

More information

G3FM. Model Number Structure. Ordering Information. Solid State Relays. Model Number Legend. List of Models

G3FM. Model Number Structure. Ordering Information. Solid State Relays. Model Number Legend. List of Models Solid State Relays CSM DS_E_5_3 100-μA-max. Leakage Current, No Bleeder Resistor Required Reduces wiring work by 60% when combined with the PFY-08- PU Push-In Plus Socket (according to actual OMRON measurements).

More information

RE7YA12BU time delay relay for star-delta starter s - 24 V AC DC - 2OC

RE7YA12BU time delay relay for star-delta starter s - 24 V AC DC - 2OC Characteristics time delay relay for star-delta starter - 0.05..1 s - 24 V AC DC - 2OC Main Range of product Product or component type Contacts type and composition Component name Time delay type Time

More information

P2-04DAL-2 Analog Output. Removable Terminal Block Specifications

P2-04DAL-2 Analog Output. Removable Terminal Block Specifications WARNING: To minimize the risk of potential safety problems, you should follow all applicable local and national codes that regulate the installation and operation of your equipment. These codes vary from

More information

TRC-190 User s Manual

TRC-190 User s Manual User s Manual Edition 3.2, May 2017 www.moxa.com/product 2017 Moxa Inc. All rights reserved. User s Manual The software described in this manual is furnished under a license agreement and may be used only

More information

NJ-Series Power Supply Unit NJ-PA/PD

NJ-Series Power Supply Unit NJ-PA/PD NJ-Series Power Supply Unit CSM_NJ-PA_PD_DS_E_1_2 Powerful power supply unit to supply stable power to the NJ-series controller. Stable power supply is available from the NJ-series CPU Unit to each I/O

More information

MINI-PS AC/10-15DC/8

MINI-PS AC/10-15DC/8 Primary-Switched Power Supply, Narrow Design Data Sheet 08/2004 MINI POWER provides: An extra narrow design, with widths of 22.5 mm, 45 mm, and 67.5 mm (0.886, 1.772, and 2.657 in.) Global use due to a

More information

RM35LM33MW liquid level control relay RM35-L V AC/DC

RM35LM33MW liquid level control relay RM35-L V AC/DC Characteristics liquid level control relay RM35-L - 24..240 V AC/DC Complementary reset time maximum switching voltage Main range of product product or component type relay type relay name relay monitored

More information

Conductive Level Controller

Conductive Level Controller Conductive Level Controller 61F-D21T-V1 Ideal for level control for industrial facilities and equipment. Outputs can be set to self-hold at ON or OFF using self-holding circuits. Sensitivity adjustment

More information

LFWLP350 SERIES 350 Watt Open Frame Power Supply Measures: 5.00 x 3.00 x 1.00

LFWLP350 SERIES 350 Watt Open Frame Power Supply Measures: 5.00 x 3.00 x 1.00 Features 5 x 3 x 1 Inches Form factor 350 Watts with Forced Air Cooling & 200 Watts Convection Cooling Efficiencies upto 94% -40 to 70 degree operating temperature* 12V / 0.5A Fan Output, Thermal Shut-Down

More information

Series AME10-VZ 10 Watt AC-DC / DC-DC Converter

Series AME10-VZ 10 Watt AC-DC / DC-DC Converter Click on Series name for product info on aimtec.com FEATURES: Picture Coming Soon I/O Isolation 000VAC Continuous Short circuit protection Operating Temp: -0 C to + C Energy Star compliant Input: -VAC,

More information

Functional configuration Rated input voltage Power ratings Output voltage Output current Part number Non-PFC

Functional configuration Rated input voltage Power ratings Output voltage Output current Part number Non-PFC Switching Power Supply DIN-Rail Mount Power Supply With Capacity Up to 240 W for General or Industrial Applications Wide power range: 15 to 240 W 15 W and PFC Models with Universal voltage of 100 to 230

More information

The Complete System Solution!

The Complete System Solution! dvantages of the Class 6 Solid State Relay The Complete System Solution! Optional Heat Sink (SSR-HS-1) Section 3 p. Optional Thermal Pad (SSR-TP-1) Section 3 p.21 We at Magnecraft strive to be your one-stop-shop

More information

Electrical Specification for: efo Wide range AC/DC Single 12V Output 400W Power Supply Telkoor Part Number: CUSTOMER SIZE CAGE CO

Electrical Specification for: efo Wide range AC/DC Single 12V Output 400W Power Supply Telkoor Part Number: CUSTOMER SIZE CAGE CO Electrical Specification for: efo400-112 Wide range AC/DC Single 12V Output 400W Power Supply Telkoor Part Number: 900-4136-0000 GENERAL SCALE RELEASE DATE PRELIMINARY SHEET 1 OF 5 REVISION HISTORY Rev

More information

5 x 8.5 x 1.61 Inch Form Factor. Convection Cooling Rated. Approved to EN Dual Fusing. Current Sharing. Open Frame. Peak Power Capability

5 x 8.5 x 1.61 Inch Form Factor. Convection Cooling Rated. Approved to EN Dual Fusing. Current Sharing. Open Frame. Peak Power Capability The MCC600 Series of open-frame medical power supplies, with its wide universal 85-264 VAC input range, is available at 600 W of output power and a variety of single output voltages. The MCC series is

More information

RM22LA32MR Level control relay RM22-L V AC/DC - 2 C/O

RM22LA32MR Level control relay RM22-L V AC/DC - 2 C/O Product datasheet Characteristics RM22LA32MR Level control relay RM22-L - 24..240 V AC/DC - 2 C/O Main Range of product Product or component type Relay type Relay name Relay monitored parameters Time delay

More information

User Manual. 400Amp AC Clamp Meter + NCV. Model MA430. Additional User Manual Translations available at

User Manual. 400Amp AC Clamp Meter + NCV. Model MA430. Additional User Manual Translations available at User Manual 400Amp AC Clamp Meter + NCV Model MA430 Additional User Manual Translations available at www.extech.com Introduction Congratulations on your purchase of this Extech MA430 Clamp Meter. This

More information

Mini Digital Multimeter

Mini Digital Multimeter User Manual Mini Digital Multimeter Model MN15A Additional User Manual Translations available at www.extech.com Introduction Congratulations on your purchase of the Extech MN15A MultiMeter. The MN15A offers

More information

E2K-F. Flat Capacitive Sensor with a Thickness of Only 10 mm. Flat Proximity Sensor. Ordering Information. Sensors [Refer to Dimensions on page 4.

E2K-F. Flat Capacitive Sensor with a Thickness of Only 10 mm. Flat Proximity Sensor. Ordering Information. Sensors [Refer to Dimensions on page 4. Flat Proximity Sensor EK-F CSM_EK-F_DS_E Flat Capacitive Sensor with a Thickness of Only mm Flat Sensor with excellent space efficiency. (Model with built-in Amplifier is only mm thick.) Direct mounting

More information

User's Guide. MiniTec TM Series Model MN25 MultiMeter

User's Guide. MiniTec TM Series Model MN25 MultiMeter User's Guide MiniTec TM Series Model MN25 MultiMeter Warranty EXTECH INSTRUMENTS CORPORATION warrants this instrument to be free of defects in parts and workmanship for one year from date of shipment (a

More information

E2K-X4ME1 2M E2K-X4ME2 2M

E2K-X4ME1 2M E2K-X4ME2 2M Cylindrical Proximity Sensor EK- CSM_EK-_DS_E 1 General-purpose Threaded Sensor That Detects Metals and Non-metals Alike Detects both metallic and nonmetallic objects (water, oil, glass, plastic, etc.).

More information

Electrical Specifications. Input Current 115 VAC: 1 A max. 230 VAC: 0.5 A max.

Electrical Specifications. Input Current 115 VAC: 1 A max. 230 VAC: 0.5 A max. MLP75 Medical Features 3 x 2 x 1 Inches Form factor 75 Watts Convection Approval to EN60601 3 rd Edition Efficiencies upto 93% -40 to 70 degree operating temperature Dual fusing Thermal Shut-Down feature

More information

Aluminum Capacitors Power Printed Wiring Style

Aluminum Capacitors Power Printed Wiring Style Aluminum Capacitors Power Printed Wiring Style FEATURES Very long useful life: 12 000 h at +85 C High ripple current capability High resistance to shock and vibration Polarized aluminum electrolytic capacitors,

More information

CVN300-96P01A SERIES. Five Output. Special Features

CVN300-96P01A SERIES. Five Output. Special Features CVN300-96P01A SERIES Embedded Power for Business-Critical Continuity CVN300-96P01A SERIES 1 of 8 Total Power: W Input Voltage: VDC # of Outputs: 5 Special Features Server Systems Infrastructure (SSI) entry-level

More information

Features. Case Material: Molded Plastic, Green Molding Compound. Computers and Peripheral

Features. Case Material: Molded Plastic, Green Molding Compound. Computers and Peripheral LOW CAPACITANCE BIDIRECTIONAL TVS DIODE Product Summary V BR (Min) I PP (Max) C T (Typ) 15V 9A 2pF Description This new generation TVS is designed to protect sensitive electronics from the damage due to

More information

SMP75. Trisil for telecom equipment protection. Features. Description. Applications. Benefits

SMP75. Trisil for telecom equipment protection. Features. Description. Applications. Benefits Trisil for telecom equipment protection Features bidirectional crowbar protection voltage: 8 V low leakage current: I R = 2 µa max holding current: I H = 15 ma min repetitive peak pulse current: I PP =

More information

G3S4-A 5 VDC 12 VDC 24 VDC 0.6 A at 75 to 264 VAC (See note 1.) G3S4-A1 5 VDC 12 VDC 24 VDC Yes G3SD-Z01P-PD 1 A at 3 to 26 VDC (See note 2.

G3S4-A 5 VDC 12 VDC 24 VDC 0.6 A at 75 to 264 VAC (See note 1.) G3S4-A1 5 VDC 12 VDC 24 VDC Yes G3SD-Z01P-PD 1 A at 3 to 26 VDC (See note 2. Terminal SSR G3S CSM_G3S_DS_E_7_ Compact Terminal SSR with Outputs Easy-to-use SSR block that combines four compact G3S SSRs, sockets, and heat sink in one unit. Easy wiring with separate I/O terminal

More information

40 & 60 Watt Models. Low Leakage Current. EN61000 Compliant. Single & Multiple Outputs. Cover Kits Available

40 & 60 Watt Models. Low Leakage Current. EN61000 Compliant. Single & Multiple Outputs. Cover Kits Available ECM40-60 40 & 60 Watt Models Small Size 2.0 x 4.0 x 1.2 Low Leakage Current Industrial & Medical Approvals Full Load Available Convection Cooled Wide Operating Temperature 0 C to +70 C Level B Conducted

More information

Features, Benefits and Functions

Features, Benefits and Functions .5-44 September 2011 Sheet 084 PSG Series DC Power Supplies PSG Series General Description Eaton s PSG Series of power supplies is designed to be a high-performance, high-quality line of products covering

More information

LFWLP225 SERIES 225 Watt Open Frame Power Supply Measures: 4.00 x 2.00 x 1.00

LFWLP225 SERIES 225 Watt Open Frame Power Supply Measures: 4.00 x 2.00 x 1.00 Features 4 x 2 x 1 Inches Form factor 225 Watts with Forced Air Cooling Efficiencies upto 94% -40 to 70 degree operating temperature* 12V / 0.5A Fan Output, Thermal Shut-Down feature 3.37m Hours, Telcordia

More information

Bulletin 700-SH Solid-State Relays. Overview/Product Selection. Bulletin 700-SH. Product Selection

Bulletin 700-SH Solid-State Relays. Overview/Product Selection. Bulletin 700-SH. Product Selection Overview/Product Selection Bulletin 700-SH 40 A (resistive) Max. Continuous (Output) Current with Heat Sink 264V AC or 528V AC Max. Voltage Range Options 5 24V DC, 100 120V AC, 200 240V AC Control Input

More information

E2KQ-X. Fluororesin-coated Capacitive Sensor with Sensitivity Adjuster. Chemical-resistant Proximity Sensor. Ordering Information

E2KQ-X. Fluororesin-coated Capacitive Sensor with Sensitivity Adjuster. Chemical-resistant Proximity Sensor. Ordering Information Chemical-resistant Proximity Sensor E2KQ-X CSM_E2KQ-X_DS_E_4_3 Fluororesin-coated Capacitive Sensor with Sensitivity Adjuster Excellent resistance against chemicals and oil with fluororesincoated case.

More information

Series AM20EW-NZ 20 Watt DC-DC Converter

Series AM20EW-NZ 20 Watt DC-DC Converter FEATURES:0 Series AM0EW-NZ Models Single output Model Input Voltage (V) Efficiency up to 90% On/Off Remote Control Ultra-wide : Input range Over Voltage Protection No-load consumption 0.W I/Output Isolation

More information

PHOENIX CONTACT - 08/2009. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

PHOENIX CONTACT - 08/2009. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area. Primary-switched power supply for building automation INTERFACE Data sheet 103505_en_02 1 Description PHOENIX CONTACT - 08/2009 Features STEP POWER power supply units for building automation The new STEP

More information

Gelo LED Driver 100W, Single output RGLD100-24

Gelo LED Driver 100W, Single output RGLD100-24 Features Gelo LED power supplies are designed specifically for use in refrigeration, retail display and sign applications. The industry standard footprint and very low profile design provide great benefits

More information

Maximun Ratings and Electrical Characteristics at 25 C

Maximun Ratings and Electrical Characteristics at 25 C , FB25, FB35,, Power - Power L Voltage Current 50 to 1000 V 15-25-35-40-50 A FEATURES High case dielectric strength High forward surge current capability UL recognition file number E320541, Vol. 2. Universal

More information

Output Voltage* (nom.)(adjustable)

Output Voltage* (nom.)(adjustable) Industrial Power Supplies TBLC Series, 6 90 W Low profile case, module depth only 55 mm Suitable for mounting in domestic installation panels Very high efficiency and low standby power -> compliance to

More information