Manual Motor Protectors

Size: px
Start display at page:

Download "Manual Motor Protectors"

Transcription

1 94 MOTOR CONTROLS Manual Motor Protectors 30 IMM16 Frame IMM32 Frame IMM65 Frame E E High interrupt capacity up to 100kA (with optional current limiter) Din rail mounting Lockable handle (OFF position) IP20 finger safe terminals Class 10 thermal overload protection Trip test feature Phase loss protection Complies with IEC and IEC , UL508 Listed (Manual motor controller) UL508 Listed (Combination motor controller starter) CSA C.22.2/14 1 year warranty 35 1 YR 1 UP TO 10HP YR 1 UP TO 2 YR WARRANTY WARRANTY WARRANTY 114 UP TO 60HP E UL HP Ratings Thermal Short Circuit Current Part Number Price Single Phase Three Phase Adjustable Rating (SCCR) 115V 230V 200V 230V 460V 575V Range (A) 480V 600V 16 Amp Frame, Pushbutton Operator IMM16-P16A to kA 10kA IMM16-P25A to kA 10kA IMM16-P40A to kA 10kA IMM16-P63A to kA 10kA IMM16-1P0A / to kA 10kA IMM16-1P6A 30-1/ /4 3/4 1.0 to kA 10kA IMM16-2P5A 30-1/6 1/2 1/ /2 1.6 to kA 10kA IMM16-4P0A 30 1/8 1/3 3/4 3/ to kA 10kA IMM16-6P3A 30 1/4 1/ / to kA 10kA IMM16-010A 32 1/2 1-1/ /2 6.3 to 10 50kA 5kA IMM16-016A to 16 30kA 5kA 32 Amp Frame, Rotary Operator IMM32-P16A to kA 25kA IMM32-P25A to kA 25kA IMM32-P40A to kA 25kA IMM32-P63A / to kA 25kA IMM32-1P0A /2 1/ to kA 25kA IMM32-1P6A 38-1/10 1/4 1/3 3/ to kA 25kA IMM32-2P5A 38-1/6 1/2 1/2 1-1/2 1-1/2 1.6 to kA 25kA IMM32-4P0A 40 1/8 1/3 3/ to kA 25kA IMM32-6P3A 40 1/4 3/4 1-1/2 1-1/ to kA 25kA IMM32-010A 40 1/2 1-1/ / to 10 50kA 25kA IMM32-016A to 16 50kA 25kA IMM32-020A / / to 20 50kA 25kA IMM32-025A /2 7-1/ to 25 50kA 25kA IMM32-032A to 32 42kA 25kA 65 Amp Frame, Rotary Operator IMM65-040A / to 40 35kA 10kA IMM65-050A to 50 35kA 10kA IMM65-065A to 65 35kA 10kA To Order Call or Visit factorymation.com

2 Manual Motor Protectors (cont d) 95 IMA-TDH Through-the-door Handle UL Type 1/IP55 & UL Type 4X/IP65 Padlockable & Defeatable Rotary Handle Adjustable shafts Shows IMM position I (ON) or O (OFF) Available in Gray/Black or Red/Yellow Shown attached to Manual Motor Starter (sold separately) TYPE 1 / IP55 & TYPE 4X / IP65 PROTECTION IMA-TDH E Part Number Price Handle Color IMA-TDH B1 18 Gray/Black IMA-TDH Y1 18 Red/Yellow IMA-TDH B4X 24 Gray/Black IMA-TDH Y4X 24 Red/Yellow IMA-TDH B1 19 Gray/Black IMA-TDH Y1 19 Red/Yellow IMA-TDH B4X 26 Gray/Black IMA-TDH Y4X 26 Red/Yellow IMA-TDH B4X 24 Gray/Black IMA-TDH Y4X 24 Red/Yellow IMA-TDH B4X 26 Gray/Black IMA-TDH Y4X 26 Red/Yellow Environmental Rating TYPE 1 / IP55 TYPE 4X / IP65 TYPE 1 / IP55 TYPE 4X / IP65 TYPE 4X / IP65 TYPE 4X / IP65 Shaft Length " ( mm) " ( mm) " ( mm) " ( mm) Applicable MMP IMM32 IMM32 IMM65 MOTOR CONTROLS IMM Bus Bars For parallel connection with IMM to contactor power terminals Simplifies wiring and reduces wiring space Multiple bus bars can be combined providing total current rating Total maximum current rating 690VAC Link Adapters For electrical and mechanical direct connection between IMM and contactor Simplifies wiring and reduces wiring space Part Number Price Description IMA-LNKADP-16F-16MC 7 For IMM16 + IMCxxx-07S to IMCxxx-16S IMA-LNKADP-16F-25MC 7 For IMM16 + IMCxxx-25S IMA-LNKADP-32F-16MC 7 For IMM32 + IMCxxx-07S to IMCxxx-16S IMA-LNKADP-32F-25C 7 For IMM32 + ICxxx-09S to ICxxx-25S (IC contactor AC Coils Only) IMA-LNKADP-32F-40C 7 For IMM32 + ICxxx-32S to ICxxx-40S (IC contactor AC Coils Only) IMA-ENCL-16FY IMA-LNKADP-32F IMA-ENCL-32xx IMA-BBS32F-54-4 IMA-BBLST IMA-BBSHROUD Enclosed Disconnect Stations Conveniently house manual motor protector in sealed enclosure Two cable entry knockouts top and bottom Includes neutral and ground terminals Wide model available to accommodate side mounting accessories Part Number Price Description IMA-ENCL-16FY 16 Standard Disconnect Station with translucent membrane for IMM16, Red/Yellow, IP66 IMA-ENCL-32FB 18 Standard Disconnect Station for IMM32, Black, IP55 IMA-ENCL-32FY 18 Standard Disconnect Station for IMM32, Red/Yellow, IP55 IMA-ENCL-32FWB 20 Wide Disconnect Station for IMM32, Black, IP55 IMA-ENCL-32FWY 20 Wide Disconnect Station for IMM32, Red/Yellow, IP55 IMA-BBS32F Part Number Price Description IMA-BBS32F mm for 2 IMM16 or IMM32., 63A max. total IMA-BBS32F mm for 3 IMM16 or IMM32., 63A max. total IMA-BBS32F mm for 4 IMM16 or IMM32., 63A max. total IMA-BBS32F mm for 5 IMM16 or IMM32., 63A max. total IMA-BBS32F mm for 2 IMM16 or IMM32 w/ side mount aux., 63A max. total IMA-BBS32F mm for 3 IMM16 or IMM32 w/ side mount aux., 63A max. total IMA-BBS32F mm for 4 IMM16 or IMM32 w/ side mount aux., 63A max. total IMA-BBS32F mm for 5 IMM16 or IMM32 w/ side mount aux., 63A max. total IMA-BBS32F mm for 2 IMM16 or IMM32 with 2 side mounting aux contacts IMA-BBS32F mm for 3 IMM16 or IMM32 with 2 side mounting aux contacts IMA-BBS32F mm for 4 IMM16 or IMM32 with 2 side mounting aux contacts IMA-BBS32F mm for 5 IMM16 or IMM32 with 2 side mounting aux contacts IMA-BBSHROUD 3 Busbar Shroud for unused IMA-BBS32F & IMA-BBS54F terminals IMA-BBLST 9 Accessories Part Number Price Description Auxiliary Contacts IMA-AUX-F11 8 Front mount, 1 N.O./1 N.C., 250V max IMA-AUX-S02 10 Left side mount, 2 N.C., 600V max IMA-AUX-S11 10 Left side mount, 1 N.O./1 N.C., 600V max IMA-AUX-S20 10 Left side mount, 2 N.O., 600V max Alarm & Trip Signaling Switch IMA-ALARM-S02 12 Left side mount, 1 N.O./1 N.C. for short-circuit signaling and 1 N.O./1 N.C. for overload signaling Shunt Release IMA-SHR-AC24 17 Right side mount, 20-24V, 50/60Hz IMA-SHR-AC Right side mount, 110V-127V, 50/60Hz IMA-SHR-AC Right side mount, V, 50/60Hz Undervoltage Release IMA-UVR-AC24 17 Right side mount, 24V, 50Hz/60Hz IMA-UVR-AC Right side mount, 110V-120V, 50/60Hz IMA-UVR-AC Right side mount, /127V, 50/60Hz IMA-UVR-AC Right side mount, 208V, 60Hz IMA-UVR-AC Right side mount, 240V, 60Hz IMA-UVR-AC Right side mount, 2 N.O. Contacts, /480V, 50/60Hz Current Limiter IMA-CURLIM-32F 31 Provides enhanced short-circuit interrupt rating: 100kA@480V for Mounting Adapters IMA-MBDOL-32F 13 For DOL Starters, 45mm, use w/ IMM32 + IMCxxx-07S to IMCxxx- 25S or ICxxx-09S to ICxxx-25S IMA-MBREV-32F 17 For Reversing Starters, 90mm, use w/ IMM32 + (2) IMCxxx-07S to -25S or (2) ICxxx-09S to -25S IMA-MBYDEL-32F 26 For Star-Delta Motor Starters, 90mm, use w/ IMM32 + (2) IMCxxx- 07S to -25S or (2) ICxxx-09S to -25S IMA-MNTTAB 1 Mounting tabs for (1) IMM16, IMM32 & IMM65 direct mount to any surface using screws, 2pc/pkg Scale Protection Cover IMA-SDPC 3 For IMM16, IMM32 & IMM65 adjustment dial Incoming Power Terminals IMA-TYPEE-32F 13 For IMM32 IMA-TYPEE-65F 25 For IMM65 Incoming Power Terminal for Bus Bar System, 3-pole, IMM16 & IMM32 IMA-AUX-F11 IMA-ALARM-S02 IMA-CURLIM-32F ONLINE ORDERS FREESHIPPING SMALL PACKAGES MIN. 29 LTL FREIGHT MIN. SEE INSIDE BACK COVER FOR MORE DETAILS

3 96 Manual Motor Protectors (cont d) MOTOR CONTROLS General Specifications General Specifications IMM16 IMM32 IMM65 Standards IMM Terminal Specifications 16 Amp Frame 32 Amp Frame 65 Amp Frame IEC / , EN / EN , UL508, CSA C.22.2/14 Rated Insulation (Ui) & Operating (Ue) Voltage [V] UL/CSA: 600V, IEC : 690V Rated Impulse Voltage Acc. IEC [kv] 6 Rated Operating Frequency [Hz] 50/60 Overvoltage Category Phase Failure Sensitivity Protection Overload Protection Characteristics (x lu) [A] 0.61 to 1 Magnetic Release (x lu) [A] 13 Overload Trip Class 10 Total Power Loss Pv At Rated Load Operating Temp [W] 6 6 (1.6A to 16A) / 8 (20A to 32A) 25 Utilization Category Lifespan Degree of Protection Resistance IEC (Motor Protector) IEC (Motor Starter) III Yes A AC-3 Mechanical: 100,000 ops., Electrical (le max.): 100,000 ops., Switching Rate (motor start) AC-3: 15 ops/hr IP20 Shock resistance: 15g/11ms, Vibration resistance: 10g/5-150Hz Screw Driver Philips #2 Philips #2 Allen #4 Terminal Capacity Environmental Conditions Solid - Stranded 1 or 2 conductors (18 to 12 AWG) (see IMM Terminal Specs) (see IMM Terminal Specs) Tightening Torque [lb-in] 11 to 16 lb-in (1.2 to 1.7 Nm) 18 to 22 lb-in (2.0 to 2.5 Nm) 55 lb-in (6.2 Nm) Ambient Temperature Storage: -58 to 176 F (-50 to 80 C), Operating: -4 to 140 F (-20 to 60 C) Climatic Proofing IEC / IEC Altitude (Up to 6,600ft) Altitude (Up to 6,600ft): Nominal values, Pollution degree: 3, Mounting position: Any Weight [lb] Warranty Drawing (mm 2 ) (AWG) 10 Terminal Capacity IMM16/IMM32 1 or 2 x (1 to 2.5) 1 or 2 x (2.5 to 6) or 2 x (14 to 10) 1 x (8) 1 or 2 x (1 to 2.5) 1 or 2 x (2.5 to 6) 1 or 2 x (14 to 10) 1 x (10) Terminal Capacity IMM65 Solid Ferrule Stranded Tightening Torque 1 Conductor on Lower Part Only 12 to 2 AWG 12 to 2 AWG A A 2 Conductors, 1 on Upper Part (A) and 1 on Lower Part (B) 16 to 2 AWG 16 to 2 AWG 12 to 2 AWG 16 to 2 AWG 16 to 2 AWG 12 to 2 AWG 8 to 2 AWG 14 to 2 AWG 14 to 2 AWG 8 to 2 AWG 55 lb-in (6.2 Nm) B B 1 year Trip Characteristics Extended Rotary Handle Dimensions in(mm) Manual Motor Protector Dimensions in(mm) B A A C D Average Curves Curve 1: 3 pole Curve 2: Bipolar with phase loss sensitivity Tripping time as function of the current at cold condition. For warm condition (after submitted to the rated operational current - Ie ), the tripping times reduce to approximately 25%. E-Handle Type A Min Max Inches (mm) MMS Type IMA-THD32 (TYPE 1) ( ) IMM32 IMA-TDH32 (TYPE 4X) ( ) IMM32 IMA-TDH65 (TYPE 4X) ( ) IMM65 in (mm) Dimensions A B C D IMM (76) 1.77 (45) 3.94 (100) 1.77 (45) IMM (98) 1.77 (45) 3.82 (97) 1.77 (45 IMM (157) 2.13 (54) 4.92 (125) 4.50 (114) The characteristics of the magnetic trip are based on the upper value of the setting range for IMM16, IMM32 & IMM65. To Order Call or Visit factorymation.com

4 Miniature Contactors & Overloads 97 1 YR WARRANTY 16A Frame 1/ 1 E E / to 1 Surface or DIN rail mountable UL508 Listed 50/60Hz AC and DC coil versions available Direct-mounting overloads RoHS compliant Auxiliary contacts standard (16A Frame) IEC year warranty Optional Accessories Include: Additional auxiliary contact blocks Reverse mounting kits and interlocks Surge suppressors Direct mount to Manual Motor Starter (with optional adapter) Miniature Thermal Overload Relays IMCA-LCHBLK-16F 3-pole Contactors 3-pole Overloads 2-pole Overloads Price Current Range Applicable Contactor IMOL-16S-P40 IMOLS-16S-P A IMOL-16S-P63 IMOLS-16S-P A IMCxxx-07S IMOL-16S-P80 IMOLS-16S-P A IMCxxx-09S IMOL-16S-1P2 IMOLS-16S-1P A IMCxxx-12S IMOL-16S-1P8 IMOLS-16S-1P A IMCxxx-16S IMOL-16S-2P8 IMOLS-16S-2P A IMOL-16S-4P0 IMOLS-16S-4P A IMOL-16S-6P3 IMOLS-16S-6P A IMOL-16S-8P0 IMOLS-16S-8P A IMCxxx-07S IMCxxx-09S IMOL-16S-010 IMOLS-16S A IMCxxx-12S IMOL-16S-012 IMOLS-16S A IMCxxx-16S IMOL-16S-015 IMOLS-16S A IMOL-16S-017 IMOLS-16S A IMOL-25S-023 IMOLS-25S A IMOL-25S-032 IMOLS-25S A IMCxxx-25S IMHA-SMB-25F 4 FMX Separate Mounting Bracket for IMOL-16S to IMOL-25S, screw or DIN-rail mountable IMOL-16S A Part Number UL HP Ratings (AC3 Motor Load) Optional Price Coil Voltage Single Phase Three Phase Overload 1 N.O. Aux Contact 1 N.C. Aux Contact 115V 230V 230V 460V 575V Relay 16A Frame Size IMC330-07S-10-AC24 IMC330-07S-01-AC VAC (60Hz) IMC330-07S-10-AC120 IMC330-07S-01-AC /120VAC (50/60Hz) IMC330-07S-10-AC240 IMC330-07S-01-AC VAC (60Hz) 1/ 3/4HP 1-1/2HP IMC330-07S-10-AC480 IMC330-07S-01-AC /480VAC (7.2A) (9A) (7A) (7A) (9A) IMOL-16S IMC330-07S-10-DC VDC IMC330-07S-10-DC24 IMC330-07S-01-DC VDC IMC330-09S-10-AC VAC (60Hz) IMC330-09S-10-AC /120VAC (50/60Hz) IMC330-09S-10-AC VAC (60Hz) IMC330-09S-10-AC /480VAC (50/60Hz) IMC330-09S-10-DC VDC IMC330-09S-10-DC VDC IMC330-12S-10-AC VAC (60Hz) IMC330-12S-10-AC /120VAC (50/60Hz) IMC330-12S-10-AC VAC (60Hz) IMC330-12S-10-AC /480VAC (50/60Hz) IMC330-12S-10-DC VDC IMC330-12S-10-DC VDC IMC330-16S-10-AC24 IMC330-16S-01-AC VAC (60Hz) IMC330-16S-10-AC120 IMC330-16S-01-AC /120VAC (50/60Hz) IMC330-16S-10-AC240 IMC330-16S-01-AC VAC (60Hz) IMC330-16S-10-AC480 IMC330-16S-01-AC /480VAC (50/60Hz) IMC330-16S-10-DC VDC IMC330-16S-10-DC24 IMC330-16S-01-DC VDC IMC330-16S-10-DC VDC 25A Frame Size (Aux contacts sold separately) IMC330-25S-00-AC VAC (60Hz) IMC330-25S-00-AC /120VAC (50/60Hz) IMC330-25S-00-AC VAC (60Hz) IMC330-25S-00-AC /480VAC (50/60Hz) IMCA-AUX-316-F11 IMCA-MECINT-16F Mini Series Accessories 1/3 HP (9.8A) 1/ (12.8A) 1HP (16A) 1-1/2HP (22A) 1HP (12A) 2HP (16A) 2HP (17A) (25A) Part Number Price Description Auxiliary Contacts IMCA-AUX-316-F02 4 Front mount, 2 N.C., IMCxxx-07S to -16S Contactors IMCA-AUX-316-F04 7 Front mount, 4 N.C., IMCxxx-07S to -16S Contactors IMCA-AUX-316-F11 4 Front mount, 1 N.O./1 N.C., IMCxxx-07S to -16S Contactors IMCA-AUX-316-F20 4 Front mount, 2 N.O., IMCxxx-07S to -16S Contactors IMCA-AUX-316-F22 7 Front mount, 2 N.O./ 2 N.C., IMCxxx-07S to -16S Contactors IMCA-AUX-316-F40 7 Front mount, 4 N.O., IMCxxx-07S to -16S Contactors IMCA-AUX-325-F02 4 Front mount, 2 N.C., IMCxxx-25S Contactors IMCA-AUX-325-F11 4 Front mount, 1 N.O./1 N.C., IMCxxx-25S Contactors IMCA-AUX-325-F20 4 Front mount, 2 N.O., IMCxxx-25S Contactors Latch Block IMCA-LCHBLK-16F 3 For IMCxxx-07S to -16S Contactors Mechanical Interlock Block for Reversing Configuration IMCA-MECINT-16F 3 For IMCxxx-07S to -16S, front mount Reverse Wire Kit for Reversing Starters IMCA-REVKIT-16F 9 For IMCxxx-07S-01 to -16S-01 (N.C. aux. contactors only). Assemble IMOL-16S to -25S and IMM16 to 32 Surge Suppressors IMCA-DIODE-16F-DC600 3 Diode, Front Mount, VDC IMCA-RCSURG-25F-AC127 3 RC, Front Mount, VAC, 50/60Hz IMCA-RCSURG-25F-AC24 3 RC, Front Mount, 12-24VAC, 50/60Hz IMCA-RCSURG-25F-AC250 3 RC, Front Mount, VAC, 50/60Hz IMCA-RCSURG-25F-AC510 3 RC, Front Mount, VAC, 50/60Hz IMCA-VARSURG-25F-AD127 3 Varistor, Front Mount, VAC / VDC IMCA-VARSURG-25F-AD275 3 Varistor, Front Mount, VAC / VDC IMCA-VARSURG-25F-AD380 3 Varistor, Front Mount, VAC / VDC IMCA-VARSURG-25F-AD48 3 Varistor, Front Mount, 12-48VAC / 12-60VDC IMCA-VARSURG-25F-AD510 3 Varistor, Front Mount, VAC 50-60Hz Link Adapters IMA-LNKADP-16F-16MC 7 For IMM16 + IMCxxx-07S to IMCxxx-16S IMA-LNKADP-16F-25MC 7 For IMM16 + IMCxxx-25S (9A) (12A) (16A) 7-1/2HP (22A) (9A) IMA-LNKADP-32F-16MC 7 For IMM32 + IMCxxx-07S to IMCxxx-16S 7-1/2HP (11A) IMOL-16S 7-1/2HP 7-1/2HP IMOL-16S (12A) (17A) 10HP (16A) 1 (22A) 10HP (17A) 1 (27A) IMOL-16S IMOL-25S MOTOR CONTROLS IMCA-REVKIT-16F IMCA-RCSURG-25F-AC127 IMA-LNKADP-16F-16MC ONLINE ORDERS FREESHIPPING SMALL PACKAGES MIN. 29 LTL FREIGHT MIN. SEE INSIDE BACK COVER FOR MORE DETAILS

5 2.77(70) 98 Miniature Contactors & Overloads (cont d) MOTOR CONTROLS 1 YR WARRANTY 1/ 10HP E E / to 10HP Surface or DIN rail mountable UL508 Listed 50/60Hz AC and DC coil versions available IEC year warranty Optional Accessories Include: Additional auxiliary contact blocks Reverse mounting kits and interlocks Surge suppressors Dimensions in(mm) 16A Frame IMCxxx-07S to -16S 3.4(86) 2.0(51) A 4-pole Contactors 2 NO Power Poles 2 NC Power Poles Price 4 NO Power Poles Price Coil Voltage 16A Frame Size IMC422-07S-00-AC24 13 IMC440-07S-00-AC VAC (60Hz) IMC422-07S-00-AC IMC440-07S-00-AC /120VAC (50/60Hz) IMC422-07S-00-AC IMC440-07S-00-AC VAC (60Hz) IMC422-07S-00-AC IMC440-07S-00-AC /480VAC IMC422-07S-00-DC12 16 IMC440-07S-00-DC VDC IMC422-07S-00-DC24 16 IMC440-07S-00-DC VDC IMC422-07S-00-DC IMC440-07S-00-DC VDC IMC422-09S-00-AC24 14 IMC440-09S-00-AC VAC (60Hz) IMC422-09S-00-AC IMC440-09S-00-AC /120VAC (50/60Hz) IMC422-09S-00-AC IMC440-09S-00-AC VAC (60Hz) IMC422-09S-00-AC IMC440-09S-00-AC /480VAC IMC422-09S-00-DC12 17 IMC440-09S-00-DC VDC IMC422-09S-00-DC24 17 IMC440-09S-00-DC VDC IMC422-09S-00-DC IMC440-09S-00-DC VDC IMC422-12S-00-AC24 14 IMC440-12S-00-AC VAC (60Hz) IMC422-12S-00-AC IMC440-12S-00-AC /120VAC (50/60Hz) IMC422-12S-00-AC IMC440-12S-00-AC VAC (60Hz) IMC422-12S-00-AC IMC440-12S-00-AC /480VAC IMC422-12S-00-DC12 19 IMC440-12S-00-DC VDC IMC422-12S-00-DC24 19 IMC440-12S-00-DC VDC IMC422-12S-00-DC IMC440-12S-00-DC VDC IMC422-16S-00-AC24 19 IMC440-16S-00-AC VAC (60Hz) IMC422-16S-00-AC IMC440-16S-00-AC /120VAC (50/60Hz) IMC422-16S-00-AC IMC440-16S-00-AC VAC (60Hz) IMC422-16S-00-AC IMC440-16S-00-AC /480VAC IMC422-16S-00-DC12 21 IMC440-16S-00-DC VDC IMC422-16S-00-DC24 21 IMC440-16S-00-DC VDC IMC422-16S-00-DC IMC440-16S-00-DC VDC Screw Mount 1.5(38) 3.3(84) 2.2 (56) 1.8(46) UL HP Ratings (AC3 Motor Load) Single Phase Three Phase 115V 230V 230V 460V 575V 1/ (7.2A) 1/3 HP (9.8A) 1/ (12.8A) 1HP (16A) 3/4HP (9A) 1HP (12A) 2HP (16A) 2HP (17A) 1-1/2HP (7A) (9A) (12A) (16A) (7A) (9A) (9A) 7-1/2HP (11A) 7-1/2HP 7-1/2HP (12A) (17A) 10HP (16A) 10HP (17A) 2.3(58) IMC IMCA-AUX IMCA-LCHBLK-16F or IMCA-MECINT-16F 2.0(51) 2.3(58) 4.5(114) IMC IMOL IMOL-16S / -25S 1.77(45) IMCxxx-25S 3.3(84) 2.2(56) 2.3(58) IMC IMCA-AUX 3.26(83) To Order Call or Visit factorymation.com

6 Miniature Contactors & Overloads (cont d) 99 Miniature Contactor Specifications General Specifications IMCxxx-07S IMCxxx-09S IMCxxx-12S IMCxxx-16S IMCxxx-25S General Purpose Rating (A) Rated Operational Voltage (V) 12 to 690 Rated Insulation Voltage (V) UL/CSA: 600, IEC/VDE 0660: 690 Rated Impulse Voltage IEC (V) 4000 Rated Operating Frequency (Hz) 25 to 400 Degree of Protection Vibration Resistance (5 to 200Hz) Contactor Open (g) 2 Contactor Closed at Coil (g) 4 Mechanical Endurance (Million ops) 10 (AC Coil) / 12 (DC Coil) 3 (AC Coil) Electrical Endurance (Million ops) Shock Resistance (1/2 Sin Wave = 11ms) Contactor Open (g) Contactor Closed at Coil (g) Terminal Capacity Main Contacts (AWG) 1 or 2 x (18 to 12) 1 or 2 x (18 to 12) 1 or 2 x (18 to 12) 1 or 2 x (18 to 12) 1 or 2 x (18 to 10) Screw Driver Phillips #2 Phillips #2 Phillips #2 Phillips #2 Phillips #2 Tightening Torque (lb-in) Environmental Conditions Ambient Temperature IP20 Storage: -67 to 176 F (-55 to 80 C), Operating: -4 to 140 F (-20 to 60 C) Climatic Withstand According to IEC Pollution Degree 3 Mounting 35mm DIN-rail Acc. DIN EN Weight (lb) Control Circuit Ratings (AC/DC COIL) Standard Voltages Coil Operating Limits Coil Consumption (Single coils) Power Factor Operating Time Miniature Overload Specifications General Specifications 12 to 660 (60Hz) Monofrequency Coils (NO LOAD) (V) 0.85 to 1.1 Pick-up (V) 0.40 to 0.76 (AC-60Hz) / 0.40 to 0.70 (DC) Drop-out (V) 0.25 to 0.65 (AC-60Hz) / 0.15 to 0.40 (DC) Sealed (VA) 2.5 to to to to to 13.2 Inrush (VA) Closed Cos Φ Opened Cos Φ Coil Energization - N.O. (ms) 8 to 20 (AC-60Hz) / 10 to 20 (DC) 13 to 16 (AC-60Hz) Coil De-energization - N.O. (ms) 5 to 15 (AC-60Hz) / 2 to 8 (DC) 13.5 to 17 (AC-60Hz) Standards IEC / , UL 508; CSA C.22.2/14; VDE 0660/102 Number of Poles 3 Rated Operation & Insulation Voltage [V] UL/CSA: 600, IEC : 690 Rated Impulse Voltage, Uimp [kv] 6 Tripping Class 10 Phase Failure Sensitivity Current Direct Alternating [Hz] Up to 400 Shock Resistance (IEC ; 1/2 sine wave) [g/ms] 10/11 Power Terminals IP Rating Main Terminals Capacity IMOL Yes Yes IP10 Cross/Slotted Combination Stranded / Solid (UL/CSA) [AWG] 14-6 Tightening Torque [lb-in] 20 Environmental Conditions Ambient Temperature Storage: -58 to 176 F (-50 to 80 C), Operating: -4 to 158 C (-20 to 70 C) Pollution Degree 3 Higher Value of Setting Range 3 Weight [lb] 0.33 Auxiliary Contacts Specifications Front Auxiliary Contact Rated Auxiliary Contacts AC-14/15 DC-13/14 UL/CSA 1 NO / 1 NC 24V:4A, 60V:3.5A, 125V:3A, 230V:2A, 400V:1.5A, V:0.5A, 690V:0.3A 24V:1A, 60V:0.5A, 110V:0.25A, 220V:0.1A Rated Thermal Current [A] 6 Short Circuit Protection (Time-delay Fuse ) [A] 6 C600 ; R300 Auxiliary Terminals Capacity [AWG] Tightening Torque [lb-in] 13.3 MOTOR CONTROLS ONLINE ORDERS FREESHIPPING SMALL PACKAGES MIN. 29 LTL FREIGHT MIN. SEE INSIDE BACK COVER FOR MORE DETAILS

7 100 Standard Contactors & Overloads MOTOR CONTROLS 1 YR WARRANTY 25A Frame Size A 18A Frame Size E /4HP to 7 DIN rail mountable up to 105A frame UL508 Listed UL and CE Certified IEC year warranty Optional Accessories Include: Additional auxiliary contact blocks Replacement coils Mechanical interlock blocks Link adapters for MMS Coil surge suppression Electronic modules 40A Frame Size 80A Frame Size 105A Frame Size /4HP 7 Contactors Part Number Price Coil Voltage Aux. Contacts 18A Frame Size IC330-09S-10-AC VAC (60Hz) 1 N.O. IC330-09S-10-AC /120VAC (50/60Hz) 1 N.O. IC330-09S-10-AC VAC (60Hz) 1 N.O. IC330-09S-10-AC /480VAC (50/60Hz) 1 N.O. IC330-09S-10-AC /600VAC (50/60Hz) 1 N.O. IC330-09S-10-DC VDC 1 N.O. IC330-09S-01-DC VDC 1 N.C. IC330-12S-10-AC VAC (60Hz) 1 N.O. IC330-12S-10-AC /120VAC (50/60Hz) 1 N.O. IC330-12S-10-AC VAC (60Hz) 1 N.O. IC330-12S-10-AC /480VAC (50/60Hz) 1 N.O. IC330-12S-10-AC /600VAC (50/60Hz) 1 N.O. IC330-12S-10-DC VDC 1 N.O. IC330-12S-01-DC VDC 1 N.C. IC330-18S-10-AC VAC (60Hz) 1 N.O. IC330-18S-10-AC /120VAC (50/60Hz) 1 N.O. IC330-18S-10-AC VAC (60Hz) 1 N.O. IC330-18S-10-AC /480VAC (50/60Hz) 1 N.O. IC330-18S-10-AC /600VAC (50/60Hz) 1 N.O. IC330-18S-10-DC VDC 1 N.O. IC330-18S-01-DC VDC 1 N.C. 25A Frame Size IC330-25S-00-AC VAC (60Hz) - IC330-25S-00-AC /120VAC (50/60Hz) - IC330-25S-00-AC VAC (60Hz) - IC330-25S-00-AC /480VAC (50/60Hz) - IC330-25S-00-DC VDC - 40A Frame Size IC330-32S-00-AC VAC (60Hz) - IC330-32S-00-AC /120VAC (50/60Hz) - IC330-32S-00-AC VAC (60Hz) - IC330-32S-00-AC /480VAC (50/60Hz) - IC330-32S-00-DC VDC - IC330-40S-00-AC VAC (60Hz) - IC330-40S-00-AC /120VAC (50/60Hz) - IC330-40S-00-AC VAC (60Hz) - IC330-40S-00-AC /480VAC (50/60Hz) - IC330-40S-00-DC VDC - 80A Frame Size IC330-50S-00-AC VAC (60Hz) - IC330-50S-00-AC /120VAC (50/60Hz) - IC330-50S-00-AC VAC (60Hz) - IC330-50S-00-AC /480VAC (50/60Hz) - IC330-50S-00-DC VDC - IC330-65S-00-AC VAC (60Hz) - IC330-65S-00-AC /120VAC (50/60Hz) - IC330-65S-00-AC VAC (60Hz) - IC330-65S-00-AC /480VAC (50/60Hz) - IC330-65S-00-DC VDC - IC330-80S-00-AC VAC (60Hz) - IC330-80S-00-AC /120VAC (50/60Hz) - IC330-80S-00-AC VAC (60Hz) - IC330-80S-00-AC /480VAC (50/60Hz) - IC330-80S-00-DC VDC - 105A Frame Size IC330-95S-00-AC VAC (60Hz) - IC330-95S-00-AC /120VAC (50/60Hz) - IC330-95S-00-AC VAC (60Hz) - IC330-95S-00-AC /480VAC (50/60Hz) - IC330-95S-00-DC VDC - IC S-00-AC VAC (60Hz) - IC S-00-AC /120VAC (50/60Hz) - IC S-00-AC VAC (60Hz) - IC S-00-AC /480VAC (50/60Hz) - IC S-00-DC VDC - UL HP Ratings (AC3 Motor Load) Optional Single Phase Three Phase Overload 115V 230V 200V 230V 460V 575V Relay (9.8A) (10A) 0.7 (13.8A) 1HP (16A) 2HP (24A) (34A) (34A) (56A) (56A) 7. (80A) 7. (80A) 2HP (12A) (17A) (28A) (28A) 7. (40A) 7. (40A) 10HP (50A) 1 (68A) 1 (68A) 10HP 20HP (100A) (88A) (11A) (11A) (9.6A) (9.6A) (17.5A) (15.2A) 7. (25A) 7. (22A) 10HP 10HP (32.2A) (28A) 10HP 1 (32.2A) (42A) 1 1 (48.3A) (42A) 20HP 20HP (62.1A) (54A) 20HP 2 (62.1A) (68A) 2 30HP (78.2A) (80A) 30HP (92A) (7.6A) 7. (11A) 10HP (14A) 1 (21A) 20HP (27A) 30HP (40A) 40HP (52A) 50HP (65A) 50HP (65A) 60HP (77A) 40HP 7 (104A) (96A) 7. (9A) 10HP (11A) 1 (17A) 1 (17A) 2 (27A) 2 (27A) 40HP (41A) 50HP (52A) 60HP (62A) 7 (77A) 7 (77A) IOL-25S IOL-25S IOL-25S IOL-25S IOL-25S IOL-40S IOL-25S IOL-40S IOL-80S IOL-80S IOL-80S IOL- 105S IOL- 105S To Order Call or Visit factorymation.com

8 Standard Contactors & Overloads (cont d) YR WARRANTY IC L Up to 350HP UL508 Listed UL and CE Certified IEC year warranty Optional Accessories Include: Auxiliary contact blocks Replacement coils A UP TO 350HP 150 to 300A E Part Number Price Coil Voltage Aux. Contacts 150A Frame Size IC L-22-AD VAC/DC 2 N.O./2 N.C. IC L-22-AD VAC/DC 2 N.O./2 N.C. IC L-22-AD VAC/DC 2 N.O./2 N.C. IC L-22-AD VAC/DC 2 N.O./2 N.C. IC L-22-AD VAC/DC 2 N.O./2 N.C. IC L-22-AD VAC/DC 2 N.O./2 N.C. IC L-22-AD VAC/DC 2 N.O./2 N.C. IC L-22-AD VAC/DC 2 N.O./2 N.C. 180A Frame Size IC L-22-AD VAC/DC 2 N.O./2 N.C. IC L-22-AD VAC/DC 2 N.O./2 N.C. IC L-22-AD VAC/DC 2 N.O./2 N.C. IC L-22-AD VAC/DC 2 N.O./2 N.C. 300A Frame Size IC L-22-AD VAC/DC 2 N.O./2 N.C. IC L-22-AD VAC/DC 2 N.O./2 N.C. IC L-22-AD VAC/DC 2 N.O./2 N.C. IC L-22-AD VAC/DC 2 N.O./2 N.C. IC L-22-AD VAC/DC 2 N.O./2 N.C. IC L-22-AD VAC/DC 2 N.O./2 N.C. IC L-22-AD VAC/DC 2 N.O./2 N.C. IC L-22-AD VAC/DC 2 N.O./2 N.C. UL HP Ratings (AC3 Motor Load) Single Phase Three Phase 115V 230V 200V 230V 460V 575V HP (120A) 50HP (150A) 60HP (177A) Optional Overload Relay 50HP 100HP 100HP IOL-150L (130A) (124A) (99A) 60HP HP IOL-150L (154A) (156A) (144A) 7 150HP 200HP IOL-180L (192A) (180A) (192A) 7 100HP 200HP 250HP IOL-300L (221A) (248A) (240A) (242A) 100HP HP 350HP IOL-300L (285A) (312A) (302A) (336A) MOTOR CONTROLS Contactor Accessories Part Number Price Description Auxiliary Contacts ICA-AUX-F10 3 Front Mount, 1NO, for ICxxx-09S to -105S contactors ICA-AUX-F01 3 Front Mount, 1NC, for ICxxx-09S to -105S contactors ICA-AUX-S11 6 Side Mount, 1NO/1NC for ICxxx-09S to ICxxx-300L contactors ICA-AUX-S20 6 Side Mount, 2NO, for ICxxx-09S to ICxxx-300L contactors ICA-AUX-S11X 6 Side Mount, 2nd Block, 1NO/1NC, for ICxxx-09S to ICxxx-300L contactors ICA-AUX-S20X 6 Side Mount, 2nd Block, 2NO, for ICxxx-09S to ICxxx-300L contactors Mechanical Interlock Blocks ICA-MECINT02-105F 11 Side mount between two ICxxx-09S to ICxxx-105S contactors Side mount between two ICxxx-112L to ICxxx-300L contactors w/ ICA-MECINT00-300F 22 the same frame size Link Adapters (Electrical and Mechanical Direct Connection) IMA-LNKADP-32F-25C 7 For IMM32 + ICxxx-09S to ICxxx-25S (IC contactor AC Coils Only) IMA-LNKADP-32F-40C 7 For IMM32 + ICxxx-32S to ICxxx-40S (IC contactor AC Coils Only) Lug Terminals ICA-LUGS-150F FMX Lugs for ICxxx-112L to ICxxx-150L, 300 MCM to 6 AWG wire 22 size, 3 pack ICA-LUGS-180F 26 FMX Lugs for ICxxx-180L, 300 MCM to 6 AWG wire size, 3 pack ICA-LUGS-300F FMX Lugs for ICxxx-250S to ICxxx-300L, 300 MCM to 6 AWG wire 46 size, 3 pack Surge Suppressors ICA-VARSURG-105F-AC510 6 Varistor, ICxxx-09S to ICxxx-105S, 400 to 510VAC ICA-RCSURG-40F-AC48 8 RC, ICxxx-09S to ICxxx-40S, 24 to 48VAC ICA-RCSURG-40F-AC127 8 RC, ICxxx-09S to ICxxx-40S, 50 to 127VAC ICA-RCSURG-40F-AC250 8 RC, ICxxx-09S to ICxxx-40S, 130 to 250VAC ICA-RCSURG-105F-AC48 8 RC, ICxxx-50S to ICxxx-105S, 24 to 48VAC ICA-RCSURG-105F-AC127 8 RC, ICxxx-50S to ICxxx-105S, 50 to 127VAC ICA-RCSURG-105F-AC250 8 RC, ICxxx-50S to ICxxx-105S, 130 to 250VAC ICA-RCSURG-250F-AC48 8 RC, ICxxx-112L to ICxxx-250L, 24 to 48VAC ICA-RCSURG-250F-AC250 8 RC, ICxxx-112L to ICxxx-250L, 50 to 250VAC ICA-DIODE-25F-DC600 8 Diode, ICxxx-09S to ICxxx-25S, 12 to 600VDC Part Number Price Description Replacement Contactor Coils ICR-COIL-25F-AC24 9 ICxxx-09 to ICxxx-25, 24VAC, 60Hz ICR-COIL-25F-AC120 9 ICxxx-09 to ICxxx-25, 110/120VAC, 50/60Hz ICR-COIL-25F-AC240 9 ICxxx-09 to ICxxx-25, VAC, 60Hz ICR-COIL-25F-AC480 9 ICxxx-09 to ICxxx-25, /480VAC, 50/60Hz ICR-COIL-25F-AC600 9 ICxxx-09 to ICxxx-25, /600VAC, 50/60Hz ICR-COIL-25F-DC24 14 ICxxx-09 to ICxxx-25, 24VDC ICR-COIL-40F-AC24 10 ICxxx-32 to ICxxx-40, 24VAC, 60Hz ICR-COIL-40F-AC ICxxx-32 to ICxxx-40, 110/120VAC, 50/60Hz ICR-COIL-40F-AC ICxxx-32 to ICxxx-40, VAC, 60Hz ICR-COIL-40F-AC ICxxx-32 to ICxxx-40, /480VAC, 50/60Hz ICR-COIL-40F-AC ICxxx-32 to ICxxx-40, /600VAC, 50/60Hz ICR-COIL-40F-DC24 16 ICxxx-32 to ICxxx-40, 24VDC ICR-COIL-40F-DF ICxxx-32 to ICxxx-40, 208/240VAC, 50/60Hz ICR-COIL-105F-AC ICxxx-50 to ICxxx-105, 110/120VAC, 50/60Hz ICR-COIL-105F-AC ICxxx-50 to ICxxx-105, VAC, 60Hz ICR-COIL-105F-AC ICxxx-50 to ICxxx-105, /480VAC, 50/60Hz ICR-COIL-105F-AC ICxxx-50 to ICxxx-105, /600VAC, 50/60Hz ICR-COIL-105F-DC24 21 ICxxx-50 to ICxxx-105, 24VDC Replacement Contactor Coils A Frame ICR-COIL-150F-AD28* 20 ICxxx-112 to ICxxx-150, 24-28VAC/DC*Use w/icr-emod-300f-ad28* ICR-COIL-150F-AD130* 20 ICxxx-112 to ICxxx-150, VAC/DC*Use w/icr-emod-300f-ad130* ICR-COIL-150F-AD250* 20 ICxxx-112 to ICxxx-150, VAC/DC*Use w/icr-emod-300f-ad250* ICR-COIL-150F-AD* 20 ICxxx-112 to ICxxx-150, 430-VAC/DC*Use w/icr-emod-300f-ad* ICR-COIL-180F-AD28* 26 ICxxx-180L, 24-28VAC/DC*Use w/icr-emod-300f-ad28* ICR-COIL-180F-AD130* 26 ICxxx-180L, VAC/DC*Use w/icr-emod-300f-ad130* ICR-COIL-180F-AD250* 26 ICxxx-180L, VAC/DC*Use w/icr-emod-300f-ad250* ICR-COIL-180F-AD* 26 ICxxx-180L, 430-VAC/DC*Use w/icr-emod-300f-ad* ICR-COIL-300F-AD28* 33 ICxxx-250 to ICxxx-300, 24-28VAC/DC*Use w/icr-emod-300f-ad28* ICR-COIL-300F-AD130* 33 ICxxx-250 to ICxxx-300, VAC/DC*Use w/icr-emod-300f-ad130* ICR-COIL-300F-AD250* 33 ICxxx-250 to ICxxx-300, VAC/DC*Use w/icr-emod-300f-ad250* ICR-COIL-300F-AD* 33 ICxxx-250 to ICxxx-300, 430-VAC/DC*Use w/icr-emod-300f-ad* Replacement Electronic Modules ICR-EMOD-300F-AD28* 71 ICxxx-112 to ICxxx-300, 24-28VAC/DC*Use w/ ICR-COIL-xxxx-AD28* ICR-EMOD-300F-AD130* 71 ICxxx-112 to ICxxx-300, VAC/DC*Use w/ ICR-COIL-xxxx-AD130* ICR-EMOD-300F-AD250* 71 ICxxx-112 to ICxxx-300, VAC/DC*Use w/ ICR-COIL-xxxx-AD250* ICR-EMOD-300F-AD* 71 ICxxx-112 to ICxxx-300, 430-VAC/DC*Use w/ ICR-COIL-xxxx-AD* *Replacement Coils 112A and above must be paired with an Electronic Module ICA-AUX-F10 ICA-AUX-S11 IMA-LNKADP-32F Lug Terminals Surge Suppressor ONLINE ORDERS FREESHIPPING SMALL PACKAGES MIN. 29 LTL FREIGHT MIN. SEE INSIDE BACK COVER FOR MORE DETAILS

9 102 Standard Contactors & Overloads (cont d) 18 Thermal Overload Relays 3-pole Overloads 2-pole Overloads Price Aux Contacts Current Range Applicable Contactor MOTOR CONTROLS 1 YR WARRANTY IOL-25S Trip ranges from 0.28A to 420A Separate mount adapter available (through IOL-105S) Ambient compensated -4 to 140 F (-20 to 60 C) Selectable RESET button (auto or manual) Differential current / phase loss protection Isolated 1N.O. & 1 N.C. auxiliary contacts Trip class 10 UL and CE Certified UL508 / IEC year warranty IOL-80S IOL-105S IOL-40S A E IOL-25S-P40 IOLS-25S-P N.O. / 1N.C A IOL-25S-P63 IOLS-25S-P N.O. / 1N.C A IOL-25S-P80 IOLS-25S-P N.O. / 1N.C A IOL-25S-1P2 IOLS-25S-1P N.O. / 1N.C A IOL-25S-1P8 IOLS-25S-1P N.O. / 1N.C A IOL-25S-2P8 IOLS-25S-2P N.O. / 1N.C A IOL-25S-4P0 IOLS-25S-4P N.O. / 1N.C A IOL-25S-6P3 IOLS-25S-6P N.O. / 1N.C A IOL-25S-8P0 IOLS-25S-8P N.O. / 1N.C A IOL-25S-010 IOLS-25S N.O. / 1N.C 7-10A IOL-25S-012 IOLS-25S N.O. / 1N.C A IOL-25S-015 IOLS-25S N.O. / 1N.C 10-15A IOL-25S-017 IOLS-25S N.O. / 1N.C A IOL-25S-023 IOLS-25S N.O. / 1N.C A IOL-25S-032 IOLS-25S N.O. / 1N.C 22-32A ICxxx-09S ICxxx-12S ICxxx-18S ICxxx-25S ICxxx-09S ICxxx-12S ICxxx-18S ICxxx-25S ICxxx-32S ICxxx-40S IOL-40S-040 IOLS-40S N.O. / 1N.C A ICxxx-32S IOL-40S-050 IOLS-40S N.O. / 1N.C 32-50A ICxxx-40S IOL-80S-040 IOLS-80S N.O. / 1N.C 25-40A IOL-80S-050 IOLS-80S N.O. / 1N.C A IOL-80S-057 IOLS-80S N.O. / 1N.C 40-57A IOL-80S-063 IOLS-80S N.O. / 1N.C A IOL-80S-070 IOLS-80S N.O. / 1N.C A IOL-80S-080 IOLS-80S N.O. / 1N.C A IOL-105S N.O. / 1N.C 63-80A IOL-105S N.O. / 1N.C A IOL-105S N.O. / 1N.C A IOL-150L-097-LK N.O. / 1N.C 75-97A IOL-150L-112-LK N.O. / 1N.C A IOL-150L-150-LK N.O. / 1N.C A IOL-150L-215-LK N.O. / 1N.C A IOL-180L-150-LK N.O. / 1N.C A IOL-180L-215-LK N.O. / 1N.C A IOL-300L-150-LK N.O. / 1N.C A IOL-300L-215-LK N.O. / 1N.C A IOL-300L-310-LK N.O. / 1N.C A IOL-300L-420-LK N.O. / 1N.C A Overload Accessories Part Number Price Description Separate Mount Block IHA-SMB-32F 6 For IOL-25S & IOLS-25S IHA-SMB-50F 8 For IOL-40S & IOLS-40S IHA-SMB-80F 8 For IOL-80S & IOLS-80S IHA-SMB-105F 10 For IOL-105L Lug Terminals IHA-LUGS For IOL-300L-150 & IOL-300L-215, 3 pack IHA-LUGS For IOL-300L-310 & IOL-300L-420, 3 pack IHA-LUGSPCR 4 Spacers for IHA-LUGS-215 & IHA-LUGS-420 (required for UL) ICxxx-50S ICxxx-65S ICxxx-80S ICxxx-95S ICxxx-105S ICxxx-112L ICxxx-150L ICxxx-180L ICxxx-250L ICxxx-300L 130 separate mount block Lug Terminals IOL-150L To Order Call or Visit factorymation.com

10 Standard Contactors & Overloads (cont d) 103 Contactor Dimension Legend in(mm) Overload Dimension Legend in(mm) W H D D H MOTOR CONTROLS Contactor Dimensions Contactor Frame Size Contactor Specifications Contactor ICxxx-09S ICxxx-12S ICxxx-18S ICxxx-25S ICxxx-32S ICxxx-40S ICxxx-50S ICxxx-65S ICxxx-80S ICxxx-95S ICxxx-105S Rated Insulation Voltage (V) UL/CSA: 600, IEC/VDE 0660: 1000 Rated Impulse Voltage IEC (kv) Rated Operating Frequency (Hz) 25 to to to to to to to to to to to 400 Degree of Protection Vibration Resistance (5 to 200Hz) Mechanical Endurance Electrical Endurance Shock Resistance: 1/2 Sin Wave = 11ms Main Terminals IP20 IP20 IP20 IP10 IP10 IP10 IP10 IP10 IP10 IP10 IP10 Coil Terminals IP20 IP20 IP20 IP20 IP20 IP20 IP20 IP20 IP20 IP20 IP20 Auxiliary Terminals IP20 IP20 IP20 IP20 IP20 IP20 IP20 IP20 IP20 IP20 IP20 Contactor Open (g) Contactor Closed at (g) AC Coil (Million ops) AC-3 (Million ops) Contactor Open Contactor Closed at Coil Stranded/Solid 1 or 2 1 or 2 1 or 2 1 or 2 Terminal Capacity (AWG) /0 14-1/0 14-1/0 14-1/0 14-1/0 (UL/CSA) (14-10) (14-10) (14-10) (14-8) Screw Driver Philips #2 Philips #2 Philips #2 Philips #2 Philips #2 Philips #2 5/32 5/32 5/32 5/32 5/32 Tightening Torque (lb-in) Environmental Conditions Ambient Temperature Storage: -67 to 176 F (-55 to 80 C), Operating (IEC) -13 to 131 F (-25 to 55 C) Climatic Withstand According to IEC Pollution Degree 3 Mounting 35mm DIN-rail Acc. DIN EN Weight (lbs) Warranty Control Circuit Ratings (AC/DC COIL) Standard Voltages 24 to 600VAC / 24 to VDC 24 to 600 (AC) / 24 to to 600 (AC) / 24 to 240 (DC) Coil Operating Limits Coil Consumption (Single Coils) Monofrequency Coils (V) 0.85 to 1.1 (AC) 0.85 to 1.1 (AC) 0.85 to 1.1 (AC) Pick-up (V) 0.4 to 0.76 (AC/DC) 0.5 to 0.8 (AC/DC) 0.5 to 0.8 (AC) / 0.7 to 0.8 (DC) Drop-out (V) 0.25 to 0.65 (AC) / 0.15 to 0.4 (DC) 0.2 to 0.6 (AC) / 0.4 to to 0.6 (AC) / 0.4 to 0.6 (DC) Sealed (VA) 4.0 to 7.2 (AC) / 3.8 to 7.5 (DC) 9.2 to 12.5 (AC) / 6.0 (DC) 16.5 to 25 (AC) / 6.5 (DC) Inrush (VA) 70.0 (AC) / 3.8 to 7.5 (DC) 115 (AC) / 240 (DC) 295 (AC) / 340 (DC) Heat Loss (W) Power Factor Operating Time H W D in mm in mm in mm 18A (AC) A (DC) A (AC) A (DC) A (AC) A (DC) A (AC/DC) A (AC/DC) A (AC/DC) A (AC/DC) A (AC/DC) Overload Dimensions Overload H W D in mm in mm in mm IOL-25S IOL-40S/-80S IOL-105S IOL-150L-097-LK IOL-150L-112-LK IOL-150L-150-LK IOL-150L-215-LK IOL-180L IOL-300L Closed Cos Φ Opened Cos Φ Coil Energization-N.O. (ms) 35 to 45 (DC) 50 to 60 (DC) 50 to 60 (DC) Coil De-energization-N.O. (ms) 7 to 12 (DC) 55 to 60 (DC) 55 to 60 (DC) 1 year ONLINE ORDERS FREESHIPPING SMALL PACKAGES MIN. 29 LTL FREIGHT MIN. SEE INSIDE BACK COVER FOR MORE DETAILS

11 104 Standard Contactors & Overloads (cont d) MOTOR CONTROLS Contactor Specifications (cont d) Contactor ICxxx-112L ICxxx-150L ICxxx-180L ICxxx-250L ICxxx-300L Rated Insulation Voltage (V) UL/CSA: 600, IEC/VDE 0660: 1000 Rated Impulse Voltage IEC (kv) Rated Operating Frequency (Hz) 25 to to to to to 400 Degree of Protection Vibration Resistance (5 to 200Hz) Overload IOL-25S IOL-40S/80S IOL-105S/150L IOL-300L Number of Poles 3 Rated Operation & Insulation Voltage IEC [V] UL; CSA [V] 600 Rated Impulse Voltage [kv] 6 8 Tripping Class 10 Phase Failure Sensitivity Current Ambient Temperature Main Terminals IP00 IP00 IP00 IP00 IP00 Coil Terminals IP20 IP20 IP20 IP20 IP20 Auxiliary Terminals IP20 IP20 IP20 IP20 IP20 Contactor Open (g) Contactor Closed at Coil (g) Mechanical Endurance AC Coil (Million ops) Electrical Endurance AC-3 (Million ops) Shock Resistance (1/2 Sin Wave = 11ms) Terminal Capacity Contactor Open Contactor Closed at Coil Wires w/end Sleeve (AWG) 1 x 300 or 2 x x 300 or 2 x x 300 or 2 x x or 2 x x or 2 x 300 Fine - Stranded w/sleeve (mm2) 2 x (25-70) 2 x (25-70) 2 x (50-120) 2 x (50-150) 2 x (50-150) Busbars (mm) 2 x (15x3) 2 x (15x3) 2 x (20x3) 2 x (30x5) 2 x (30x5) Screw Driver Philips #2 Philips #2 Philips #2 Philips #2 Philips #2 Tightening Torque (lb-in) Environmental Conditions Ambient Temperature Direct YES NO Alternating [Hz] Up to /60 Storage Operating Storage: -67 to 176 F (-55 to 80 C), Operating (IEC) -13 to 131 F (-25 to 55 C) Climatic Withstand According to IEC 68-2 Pollution Degree 3 Mounting Screw to panel Weight (lbs) Warranty Electronic Control Module Control Circuit Ratings (AC/DC COIL) Standard Voltages (V) UL/CSA: 600, IEC/VDE 0660: 1000 Coil Operating Limits Coil Consumption (Single Coils) YES -58 to 176 F (-50 to 80 C) -4 to 158 F (-20 to 70 C) Pollution Degree 3 Current Heat Loss [W] Weight [lb] / Shock Resistance (IEC ; 1/2 Sine Wave) [g/ms] 10/11 Standards IEC / , UL 508; CSA C.22.2/14; VDE 0660/102 Power Terminals IP Rating IP10 IP00 Main Terminals Capacity Cross/Slotted Combination Allen Head Slide Bar Stranded / Solid (UL/CSA) 75 C, Cu Only [AWG] /0 8-1/0 Tightening Torque [lb-in] ( A) 230 ( A) 1 year Monofrequency Coils (V) 24 to Pick-up (V) 0.65 to 1.1 Drop-out (V) 0.70 to 0.85 Sealed (VA) 0.40 to 0.60 Inrush (VA) 40 to 85 Heat Loss (W) 50 to 75 Coil Consumption Sealed (VA/W) 14.8 (AC) / 2.4 (DC) 14.8 (AC) / 2.4 (DC) 14.1 (AC) / 2.4 (DC) 14.1 (AC) / 2.5 (DC) 14.1 (AC) / 2.5 (DC) Inrush (VA/W) 213 (AC) / 166 (DC) 213 (AC) / 166 (DC) 214 (AC) / 154 (DC) 229 (AC) / 171 (DC) 229 (AC) / 171 (DC) Heat Loss (W) 3.9 (AC) 2.4 (DC) 3.9 (AC) 2.4 (DC) 3.8 (AC) /2.4 (DC) 3.7 (AC) /2.5 (DC) 3.7 (AC) /2.5 (DC) Overload Specifications To Order Call or Visit factorymation.com

12 Manual Motor Starters 105 Formerly LG Industrial Systems E C US A HIGH SCCR SERIES High interrupt capacity Din rail and surface mounting Lockable handle (OFF position) IP20 finger safe terminals Class 10 thermal overload protection Trip test feature Part Number Price Single Phase UL HP Ratings Three Phase Phase loss protection Complies with IEC and IEC UL508 (Manual motor controller) UL508 (Combination motor controller starter) CSA C22.2 NO.14 GB14048 Thermal Adjustable Range (A) Short Circuit Current Rating (SCCR) 115V 230V 200V 230V 460V 575V 240V 480V 600V MOTOR CONTROLS MMS-32H Frame 32 Amp Frame MMS-32H-0.16A A 100kA 65kA 25kA MMS-32H-0.25A A 100kA 65kA 25kA MMS-32H-0.4A A 100kA 65kA 25kA MMS-32H-0.63A A 100kA 65kA 25kA MMS-32H-1A 42 1/ A 100kA 65kA 25kA MMS-32H-1.6A 47 1/10 3/4 3/ A 100kA 65kA 25kA MMS-32H-2.5A 47 1/6 1/2 1/ / A 100kA 65kA 25kA MMS-32H-4A 50 1/8 1/3 3/4 3/ A 100kA 65kA 25kA 45mm MMS-63H Frame MMS-32H-6A 50 1/4 1/ / A 100kA 65kA 25kA MMS-32H-8A 50 1/ A 100kA 65kA 25kA MMS-32H-10A 50 1/2 1-1/ /2 6-10A 100kA 65kA 25kA MMS-32H-13A 50 1/ / A 100kA 65kA 25kA MMS-32H-17A A 100kA 30kA 10kA MMS-32H-22A / / A 100kA 30kA 10kA MMS-32H-26A /2 7-1/ A 100kA 30kA 10kA MMS-32H-32A / A 100kA 30kA 10kA MMS-32H-40A / A 100kA 30kA 10kA 63 Amp Frame MMS-63H-17A A 100kA 50kA 10kA MMS-63H-22A / / A 100kA 50kA 10kA MMS-63H-26A /2 7-1/ A 100kA 50kA 10kA 55mm MMS-63H-32A / A 100kA 50kA 10kA MMS-63H-40A / A 100kA 50kA 10kA MMS-100H Frame MMS-63H-50A A 100kA 50kA 10kA MMS-63H-63A A 100kA 50kA 10kA 100 Amp Frame MMS-100H-75A A 100kA 50kA 10kA MMS-100H-90A / A 100kA 50kA 10kA MMS-100H-100A A 100kA 50kA 10kA 70mm ONLINE ORDERS FREESHIPPING SMALL PACKAGES MIN. 29 LTL FREIGHT MIN. SEE INSIDE BACK COVER FOR MORE DETAILS

13 106 Manual Motor Starter Accessories Extended Rotary Handle Formerly LG Industrial Systems MOTOR CONTROLS Shown attached to Manual Motor Starter (sold separately) UL Type 12, IP65 rating Available with 4.53 (115mm) or 12.4 (315mm) shaft lengths MMS Bus Bars For parallel connection with MMS power terminals Simplifies wiring and reduces wiring space Multiple bus bars can be combined providing total current rating is not exceeded MMS Auxiliary Contact Blocks Front mount auxiliary blocks Side mount auxiliary, alarm, undervoltage, and shunt trip contact blocks Front Mount TYPE 12 / IP65 PROTECTION E Part Number Price Description MMS-FX-11 9 Auxiliary Contacts, front mounting, 1 N.O., 1 N.C. MMS-FX-20 9 Auxiliary Contacts, front mounting, 2 N.O. MMS-FX-02 9 Auxiliary Contacts, front mounting, 2 N.C. MMS-LX Auxiliary Contacts, side mounting, 1 N.O., 1N.C. MMS-LX Auxiliary Contacts, side mounting, 2 N.O. MMS-LX Auxiliary Contacts, side mounting, 2 N.C. MMS-LA 14 Trip Alarm Switch, signals all faults, side mounting, 1N.O., 1N.C. for MMS-32H MMS-LA Trip Alarm Switch, side mounting, 1N.O., 1N.C. for use with MMS63H & MMS100H MMS-LAM 15 Magnetic Trip Alarm Switch, signals magnetic trip only, side mounting, 1N.O., 1N.C. contact MMS-RS Shunt Release, side mounting, 24V/50Hz, 28V/60Hz MMS-RS Shunt Release, side mounting, 110V/50Hz, 120V/60Hz MMS-RS Shunt Release, side mounting, 200V/50Hz, V/60Hz MMS-RS Shunt Release, side mounting, V/50Hz, V/60Hz MMS-RU Undervoltage Release, side mounting, 24V/50Hz, 28V/60Hz MMS-RU Undervoltage Release, side mounting, 110V/50Hz, 120V/60Hz MMS-RU Undervoltage Release, side mounting, 200V/50Hz, V/60Hz MMS-RU Undervoltage Release, side mounting, V/50Hz, V/60Hz MMS-RUX Undervoltage Release with Switch, side mounting, 2 N.O. Contacts, 24V/50Hz, 28V/60Hz MMS-RUX Undervoltage Release with Switch, side mounting, 2 N.O. Contacts, 110V/50Hz, 120V/60Hz MMS-RUX Undervoltage Release with Switch, side mounting, 2 N.O. Contacts, V/50Hz, V/60Hz MMS-MEH32-115R 21 Extended Rotary Handle and shaft, for use with MMS-32H, UL Type 3R/IP65, 4.53" (115mm) shaft length MMS-MEH32-315R 23 Extended Rotary Handle and shaft, for use with MMS-32H, UL Type 3R/IP65, 12.4 (315mm) shaft length MMS-MEH63-115R 21 Extended Rotary Handle and shaft, for use with MMS-63H, UL Type 12/IP65, 4.53" (115mm) shaft length MMS-MEH63-315R 23 Extended Rotary Handle and shaft, for use with MMS-63H, UL Type 12/IP65, 12.4 (315mm) shaft length MMS-MEH R 21 Extended Rotary Handle and shaft, for use with MMS-100H, UL Type 12/IP65, 4.53" (115mm) shaft length MMS-MEH R 23 Extended Rotary Handle and shaft, for use with MMS-100H, UL Type12/IP65, 12.4 (315mm) shaft length MMS-PB Phase Bus Bar for 32 Amp Frame, 63 amp maximum current, connects two MMS s MMS-PB Phase Bus Bar for 32 Amp Frame, 63 amp maximum current, connects three MMS s MMS-PB Phase Bus Bar for 63 Amp Frame, 108 amp maximum current, connects two MMS s MMS-PB Phase Bus Bar for 63 Amp Frame, 108 amp maximum current, connects three MMS s MMS-EPH32-65S 21 Plastic Enclosure w/ rotary handle, compatible with MMS-32H, UL Type 1/IP65, UL and CE certified, suitable for surface mounting CG-M M20x1.5, Cord Grip (IP68), 5-pack, cable size: " (10-14 mm) CG-M M20x1.5, Cord Grip (IP68), 5-pack, cable size: " (6-12 mm) Plastic MMS Enclosure TYPE 1 / IP65 PROTECTION Dimensions in(mm) 6.38 (162) 5.91 (150) 4.21 (107) E Left Side Position 2 Left Side Position 1 MMS-FX-xx Right Side MMS-EPH32-65S UL Type 1, IP65 rating Rotary handle with lockout provision UL and CE certified Available for 32 amp frame only M20/M25 knockouts 4.13 (105) 1.81 (46) MMS-LX-xx MMS-LX-xx or MMS-LA or MMS-LAM MMS-RS-xxx or MMS-RU-xxx or MMS-RUX-xxx To Order Call or Visit factorymation.com

14 107 Formerly LG Industrial Systems MMS Terminal Specifications General Specifications 32 Amp Frame 63 Amp Frame 100 Amp Frame Wire Type Conductors MMS-32H MMS-63H MMS-100H AWG 18-2 AWG 12-2/0 AWG Solid AWG 18-4 AWG 12-1/ 0 AWG AWG 18-2 AWG 12-2/0 AWG Stranded AWG 18-4 AWG 12-1/ 0 AWG AWG 18-4 AWG 12-1/0 AWG Flexible AWG 18-6 AWG 10-2 AWG Torque 7-22 lb-in lb-in lb-in Trip Characteristics MMS-32 MMS-63, 100 Standards Rated Operational Voltage (Ue) Rated Frequency Manual Motor Starter Dimensions in(mm) B A Underwriters Laboratories - UL 508, File # E252942; CSA C22.2, IEC & IEC Compliance Up to 690V 50/60Hz Rated Insulation Voltage (Ui) 32AF: 690V; 63AF - 100AF: 1,000V Rated Impulse Voltage (Uimp) Utilization Category 32AF: 6kV; 63AF - 100AF: 8kV IEC (Breaker): Cat. A; IEC (Motor starter) AC 3 Mechanical Endurance (Ops) 32AF: 100,000; 63AF - 100AF: 50,000 Electrical Endurance (Ops) 32AF: 100,000; 63AF - 100AF: 25,000 Max Operating Frequency Storage Temperature Operating Temperature Phase Loss Protection Degree of Protection Resistance to Shock Resistance to Vibration Terminal Capacity Tightening Torque Manual Motor Starter 25 operations/hour -58 to 176 F (-50 to 80 C) -4 to 140 F (-20 to 60 C) Yes IP20 25g 5-150Hz 32AF: 1 or 2 x (18-10 AWG); 63AF: 1 x (18-2 AWG) or 2 x (18-4 AWG); 100AF: 1 x (12-2/0 AWG) or 2 x (12-1/0 AWG) 32AF: Nm (7-22lb-in); 63AF: Nm (26-39lb-in); 100AF: 4-6 Nm (35-53lb-in) Inches (mm) A B C MMS-32H 1.8 (45) 3.7 (94) 3.9 (99.6) MMS-63H 2.2 (55) 5.5 (140) 5.7 (144.6) MMS-100H 2.8 (70) 6.5 (165) 6.7 (171) C MOTOR CONTROLS Extended Rotary Handle Dimensions in(mm) A E-Handle Type A Min Max Inches (mm) MEH32-115R ( ) MEH32-315R ( ) MEH ( ) MEH ( ) MEH ( ) MEH ( ) MMS Type MMS-32H MMS-63H MMS-100H ONLINE ORDERS FREESHIPPING SMALL PACKAGES MIN. 29 LTL FREIGHT MIN. SEE INSIDE BACK COVER FOR MORE DETAILS

15 108 Mini Contactors & Overloads MOTOR CONTROLS GMC-12M Surface or DIN rail mountable UL508 compliant 1/2HP to 7-1/2HP 50/60Hz AC and DC versions available Direct-mounting overloads RoHS compliant Auxiliary contacts standard (1 N.0.) UL and CE certified IEC Optional Accessories Include: Additional auxiliary contact blocks Reverse mounting kits and interlocks Time delay units Surge suppressors Direct mount to Manual Motor Starter (with optional adapter) Full Featured Contactor and Overload Top Mount Aux Contact Position Identification Labels Dial Trip Setting Finger Safe Terminals A E Aux Contacts (1 N.O.) Side Mount Aux Contact Position Reset Button Selector Trip Indicator Built-in Aux Contacts (1 N.O., 1 N.C.) MetaMec Mini Contactors (6-12A) Part Number Price Coil Voltage 6 Amp, Screw Terminals GMC-6M VAC (50/60Hz AC) GMC-6M VAC (50/60Hz AC) GMC-6M VAC (50/60Hz GMC-6M VAC (50/60Hz GMC-6M VAC (50/60Hz AC) GMD-6M VDC GMD-6M VDC 9 Amp, Screw Terminals GMC-9M VAC (50/60Hz AC) GMC-9M VAC (50/60Hz AC) GMC-9M VAC (50/60Hz GMC-9M VAC (50/60Hz GMC-9M VAC (50/60Hz AC) GMD-9M VDC GMD-9M VDC 12 Amp, Screw Terminals GMC-12M VAC (50/60Hz AC) GMC-12M VAC (50/60Hz AC) GMC-12M VAC (50/60Hz GMC-12M VAC (50/60Hz GMC-12M VAC (50/60Hz AC) GMD-12M VDC GMD-12M VDC GTK-12M A Aux. Contacts Direct Mounting to Meta-Mec Mini Contactors UL508 compliant Screw terminals Differential current UL and CE certified RoHS compliant Built-in auxiliary contacts (1 N.0., 1 N.C.) Resistive Load (AC1) 1 N.O. 20A 1 N.O. 20A 1 N.O. 20A 1 N.O. 20A 1 N.O. 20A 1 N.O. 20A Formerly LG Industrial Systems UL HP Ratings (AC3 Motor Load) Single Phase Three Phase 115V 230V 230V 460V 575V 0. (9.8A) 0. (9.8A) 0. (9.8A) 0. (9.8A) 1HP (16A) 1HP (16A) 1HP (8A) 1HP (8A) 1. (10A) 1. (10A) 2HP (12A) 2HP (12A) 1. (6A) 1. (6A) (9.6A) (9.6A) (9.6A) (9.6A) (4.8A) (4.8A) (7.6A) (7.6A) 7. (11A) 7. (11A) Mini Thermal Overload Relays Part Number Price Current Range GTK-12M-0.16A A GTK-12M-0.25A A GTK-12M-0.4A A GTK-12M-0.63A A GTK-12M-1.0A A GTK-12M-1.6A A GTK-12M-2.5A A GTK-12M-4A A GTK-12M-6A A GTK-12M-8A A GTK-12M-9A A GTK-12M-10A A GTK-12M-13A A GTK-12M-16A A (3.9A) (3.9A) (6.1A) (6.1A) 7. (9A) 7. (9A) Optional Overload Relay GTK-12M GTK-12M GTK-12M GTK-12M GTK-12M GTK-12M Applicable Contactor GMC-6M GMC-9M GMC-12M GMD-6M GMD-9M GMD-12M To Order Call or Visit factorymation.com

16 Mini Contactors & Overloads (cont d) 109 Formerly LG Industrial Systems Mini Series Accessories Part Number Price Description Auxiliary Contacts AU-1M-10 4 Side-mount, 1 N.O., GMC-6 to GMC-12 AU-1M-01 4 Side-mount, 1N.C., GMC-6 to GMC-12 AU-2M-02 6 Top-mount, 2 N.C., GMC-6 to GMC-12 AU-2M-11 6 Top-mount, 1 N.O. / 1 N.C., GMC-6 to GMC-12 AU-2M-20 6 Top-mount, 2 N.O., GMC-6 to GMC-12 AU-4M-40 7 Top-mount, 4 N.O., GMC-6 to GMC-12 AU-4M-22 7 Top-mount, 2 N.O. / 2 N.C., GMC-6 to GMC-12 AU-4M-04 7 Top-mount, 4 N.C., GMC-6 to GMC-12 Direct Adapters for Manual Motor Starter + Contactor DA-16HA 5 MMS-32H + GMC-xM (AC coil version) DA-16HD 5 MMS-32H + GMD-xM (DC coil version) Mechanical Interlocks and Reversing Kits for GMC-6 to GMC-12 AR-12M 4 Mechanical Interlock for Reversing Configuration AR-12MW 5 Mechanical Interlock and Reversing Wire Kit Contactor Plug-in Coil Surge Suppressors AS-12M-1 4 GMC-6 to GMC-12, 24-48VAC, Varistor AS-12M-2 4 GMC-6 to GMC-12, VAC, Varistor AS-12M-3 4 GMC-6 to GMC-12, VAC, Varistor AS-12M-4 4 GMD-6 to GMD-12, 12-24VDC, Varistor ON Delay and OFF Delay Timer Units AT-12M-1N 52 Timer Unit, ON Delay, s, 24 to 48V AC/DC AT-12M-1F 52 Timer Unit, OFF Delay, s, 24 to 48V AC/DC AT-12M-2N 52 Timer Unit, ON Delay, s, 100 to 220V AC/DC AT-12M-2F 52 Timer Unit, OFF Delay, s, 100 to 220V AC/DC Overload Separate Mount Units AZ-12MH 5 Separate Mount Unit for GTK12M Overloads Auxiliary Contacts AU-2M Mini Contactor and Overload Specifications Contactor Number of Poles Rated insulation voltage, Ui Short Circuit Max Current Mini Contactor Dimensions GMC-6M GMD-6M GMC-9M GMD-9M 3 pole 690V 5kA GMC-12M GMD-12M Breaking Capacity 60A 90A 120A Maximum Operations Per Hour (AC3) 1800 Mechanical Durability Electrical Durability Auxiliary Contacts (Standard) Thermal Magnetic Overload Rated Insulation Voltage, Ui 12 million operations 1 million operations 1 N.O. GTK-12M 690V Trip Class Class 10 Protection Type Auxiliary Contacts (Standard) Standards GMC, GMD, & GTK Standards Coil Current Consumption for Mini Contactors Part Number AC Coil Differential, Phase Loss, Over Current 1 N.O. / 1 N.C. UL508 File # , cul, CE DC Coil GMC-6M GMC-9M GMC-12M GMD-6M GMD-9M GMD-12M Standard Voltages 50/60Hz/ V 12-24V Operating Voltage Limits Coil Consumption Pick-up % % Drop-out 30-40% 10-30% Inrush 32VA 32VA 32VA 3W 3W 3W Sealed 6VA 6VA 6VA 3W 3W 3W Thermal Dissipation Watts Contactor A B C D E F G GMC-xM 1.77 (45mm) Dimensions in(mm) 2.51 (63.7mm) A 2.28 (58mm) 4.57 (116.1mm) B 1.77 (45mm) 6.52 (165.7mm) 3.92 (99.6mm) MOTOR CONTROLS AU-1M C Reversing Kit Time Delay Unit D Contactor & Overload AR-12MW AT-12M E G Separate Mount Unit Direct Mount Adapter F AZ-12MH (Shown attached to GTK12M overload) DA-16HA (Direct Adapter connects Mini Contactor and Manual Motor Starter, MMS-32H) Contactor & Manual Motor Starter ONLINE ORDERS FREESHIPPING SMALL PACKAGES MIN. 29 LTL FREIGHT MIN. SEE INSIDE BACK COVER FOR MORE DETAILS

17 110 Contactors & Overloads Formerly LG Industrial Systems MOTOR CONTROLS E DIN rail mountable (through 150A) UL508 Compliant 0. to 600HP Direct-Mounting Overload Relays RoHS Compliant Auxiliary Contacts Standard UL and CE Certified IEC Optional Accessories Include: Additional Auxiliary Contact Blocks Replacement Coils Reverse Wiring Kits and Interlocks Direct Wiring Adapters for MMS Coil Surge Suppression Remote Reset REMOVEABLE AUX CONTACTS A 40A Frame Size HP Metasol Contactors (9-800A) 16 Part Number Price Coil Voltage 22 Amp Frame, Screw Clamp Terminals MC-9B-11-AC VAC (50/60Hz) MC-9B-11-AC VAC (50/60Hz) MC-9B-11-AC VAC (60Hz) MC-9B-11-AC VAC (50/60Hz) MC-9B-11-AC VAC (60Hz) MC-9B-11-DC VDC MC-12B-11-AC VAC (50/60Hz) MC-12B-11-AC VAC (50/60Hz) MC-12B-11-AC VAC (60Hz) MC-12B-11-AC VAC (50/60Hz) MC-12B-11-AC VAC (60Hz) MC-12B-11-DC VDC MC-18B-11-AC VAC (50/60Hz) MC-18B-11-AC VAC (50/60Hz) MC-18B-11-AC VAC (60Hz) MC-18B-11-AC VAC (50/60Hz) MC-18B-11-AC VAC (60Hz) MC-18B-11-DC VDC MC-22B-11-AC VAC (50/60Hz) MC-22B-11-AC VAC (50/60Hz) MC-22B-11-AC VAC (60Hz) MC-22B-11-AC VAC (50/60Hz) MC-22B-11-AC VAC (60Hz) MC-22B-11-DC VDC 40 Amp Frame, Screw Clamp Terminals MC-32A-22-AC VAC (50/60Hz) MC-32A-22-AC VAC (50/60Hz) MC-32A-22-AC VAC (60Hz) MC-32A-22-AC VAC (50/60Hz) MC-32A-22-AC VAC (60Hz) MC-32A-22-DC VDC MC-40A-22-AC VAC (50/60Hz) MC-40A-22-AC VAC (50/60Hz) MC-40A-22-AC VAC (60Hz) MC-40A-22-AC VAC (50/60Hz) MC-40A-22-AC VAC (60Hz) MC-40A-22-DC VDC 65 Amp Frame, Box Lug Terminals MC-50A-22-AC VAC (50/60Hz) MC-50A-22-AC VAC (50/60Hz) MC-50A-22-AC VAC (60Hz) MC-50A-22-AC VAC (50/60Hz) MC-50A-22-AC VAC (60Hz) MC-50A-22-DC VDC MC-65A-22-AC VAC (50/60Hz) MC-65A-22-AC VAC (50/60Hz) MC-65A-22-AC VAC (60Hz) MC-65A-22-AC VAC (50/60Hz) MC-65A-22-AC VAC (60Hz) MC-65A-22-DC VDC Resistive Aux. Load Contacts (AC1) 1 N.O. 1 N.C. 1 N.O. 1 N.C. 1 N.O. 1 N.C. 1 N.O. 1 N.C. 2 N.O. 2 N.C. 2 N.O. 2 N.C. 2 N.O. 2 N.C. 2 N.O. 2 N.C UL HP Ratings (AC3 Motor Load) Single Phase Three Phase 115V 230V 200V 230V 460V 575V 0. (9.8A) 0.7 (13.8A) 1HP (16A) 2HP (24A) 2HP (24A) (34A) (34A) (65A) 1. (10A) 2HP (12A) (17A) (17A) (28A) 7. (40A) 10HP (50A) 1 (85A) 2HP (7.5A) (10.6A) (16.7A) 7. (24.2A) 7. (24.2A) 1 (46.2A) 20HP (59.4A) 2 (74.8A) (9.6A) (15.2A) 7. (22A) 10HP (28A) 10HP (28A) 1 (54A) 2 (68A) 30HP (65A) (7.6A) 7. (11A) 10HP (14A) 1 (21A) 20HP (27A) 30HP (40A) 40HP (52A) 50HP (65A) 7. (9A) 10HP (11A) 1 (17A) 20HP (22A) 2 (27A) 30HP (41A) 50HP (52A) 60HP (65A) Optional Overload Relay MT-32 MT-32 MT-32 MT-32 MT-32 MT-32 MT-63 MT-63 REMOVEABLE AUX CONTACTS 65A Frame Size To Order Call or Visit factorymation.com

18 Contactors & Overloads (cont d) 111 REMOVEABLE AUX CONTACTS REMOVEABLE AUX CONTACTS 225A Frame Size 800A Frame Size 100A Frame Size 150A Frame Size Metasol Contactors (9-800A) Part Number Price Coil Voltage 100 Amp Frame, Box Lug Terminals MC-75A-22-AC VAC (50/60Hz) MC-75A-22-AC VAC (50/60Hz) MC-75A-22-AC VAC (60Hz) MC-75A-22-AC VAC (50/60Hz) MC-75A-22-AC VAC (60Hz) MC-75A-22-DC VDC MC-85A-22-AC VAC (50/60Hz) MC-85A-22-AC VAC (50/60Hz) MC-85A-22-AC VAC (60Hz) MC-85A-22-AC VAC (50/60Hz) MC-85A-22-AC VAC (60Hz) MC-85A-22-DC VDC MC-100A-22-AC VAC (50/60Hz) MC-100A-22-AC VAC (50/60Hz) MC-100A-22-AC VAC (60Hz) MC-100A-22-AC VAC (50/60Hz) MC-100A-22-AC VAC (60Hz) MC-100A-22-DC VDC 150 Amp Frame, Box Lug Terminals MC-130A-22-AC VAC (50/60Hz) MC-130A-22-AC VAC (50/60Hz) MC-130A-22-AC VAC (50/60Hz) MC-130A-22-AC VAC (50/60Hz) MC-130A-22-DC VDC MC-150A-22-AC VAC (50/60Hz) MC-150A-22-AC VAC (50/60Hz) MC-150A-22-AC VAC (50/60Hz) MC-150A-22-AC VAC (50/60Hz) MC-150A-22-DC VDC 225 Amp Frame, Screw Terminals MC-185A-22-AC/DC VAC/24VDC MC-185A-22-AC/DC VAC/ VDC MC-185A-22-AC VAC MC-225A-22-AC/DC VAC/24VDC MC-225A-22-AC/DC VAC/ VDC MC-225A-22-AC VAC 400 Amp Frame, Screw Terminals Resistive Aux. Load Contacts (AC1) 2 N.O. 2 N.C. 2 N.O. 2 N.C. 2 N.O. 2 N.C. 2 N.O. 2 N.C. 2 N.O. 2 N.C. 2 N.O. 2 N.C. 2 N.O. 2 N.C. MC-265A-22-AC/DC VAC/ VDC 2 N.O. MC-265A-22-AC VAC 2 N.C. MC-330A-22-AC/DC VAC/ VDC 2 N.O. MC-330A-22-AC VAC 2 N.C. MC-400A-22-AC/DC VAC/ VDC 2 N.O. MC-400A-22-AC VAC 2 N.C. 800 Amp Frame, Screw Terminals MC-A-22-AC/DC100 1, VAC/ VDC MC-A-22-AC/DC200 1, VAC/ VDC MC-A-22-AC 1, VAC MC-630A-22-AC/DC100 1, VAC/ VDC MC-630A-22-AC/DC200 1, VAC/ VDC MC-630A-22-AC 1, VAC MC-800A-22-AC/DC100 1, VAC/ VDC MC-800A-22-AC/DC200 1, VAC/ VDC MC-800A-22-AC 1, VAC 2 N.O. 2 N.C. 2 N.O. 2 N.C. 2 N.O. 2 N.C UL HP Ratings (AC3 Motor Load) Single Phase Three Phase 115V 230V 200V 230V 460V 575V (56A) 7. (80A) 10HP (100A) 10HP (100A) 1 (135A) 1 (135A) 1 (135A) 1 (68A) 1 (68A) 20HP (56A) 20HP (88A) 2 (110A) 30HP (136A) 40HP (176A) 300 N/A N/A 350 N/A N/A 450 N/A N/A 580 N/A N/A 660 N/A N/A 900 N/A N/A Formerly LG Industrial Systems 2 (78A) 30HP (88A) 30HP (88A) 40HP (120A) 40HP (120A) 60HP (177A) 60HP (177A) 7 (221A) 100HP (285A) 12 (359A) 150HP (414A) 200HP (552A) 200HP (552A) 30HP (80A) 40HP (104A) 40HP (104A) 40HP (104A) 50HP (130A) 60HP (154A) 7 (192A) 100HP (248A) 12 (312A) 150HP (360A) 200HP (480A) 250HP (602A) 50HP (65A) 60HP (77A) 7 (96A) 7 (96A) 100HP (124A) 12 (156A) 150HP (180A) 200HP (240A) 250HP (302A) 300HP (361A) 400HP (477A) HP (590A) 60HP (62A) 7 (77A) 7 (77A) 7 (77A) 7 (77A) 12 (125A) 150HP (144A) 200HP (192A) 250HP (242A) 300HP (289A) 400HP (382A) HP (472A) Optional Overload Relay MT-95 MT-95 MT-95 MT-150 MT-150 MT-225 MT-225 MT-400 MT-400 MT-400 MT-800 MT HP 600HP 600HP MT-800 MOTOR CONTROLS ONLINE ORDERS FREESHIPPING SMALL PACKAGES MIN. 29 LTL FREIGHT MIN. SEE INSIDE BACK COVER FOR MORE DETAILS

19 112 Thermal Overload Relays Formerly LG Industrial Systems MOTOR CONTROLS MT-32 Thermal Overload Relay Features Dial Trip Setting Dial Cover Finger Safe Terminals A E Trip ranges from 0.1A to 800A Direct mounting to Metasol contactors Separate mount adapter available (through MT-150) Optional lug terminals for screw terminal versions, ordered separately Ambient Compensated 23 to 104 F (-5 to 40 C) Manual / Automatic Reset Differential Current / Phase Loss Protection Auxiliary contacts Included Trip Class 10 UL and CE Certified IEC Identification Label Stop/Test Button Trip Indicator Reset Button Selector Aux Contacts Part Number Price Aux Contacts Current Range MT-32S-0.16A 27 1 N.O. / 1N.C A MT-32S-0.25A 27 1 N.O. / 1N.C A MT-32S-0.4A 27 1 N.O. / 1N.C A MT-32S-0.63A 27 1 N.O. / 1N.C A MT-32S-1A 27 1 N.O. / 1N.C A MT-32S-1.6A 27 1 N.O. / 1N.C 1-1.6A MT-32S-2.5A 27 1 N.O. / 1N.C A MT-32S-4A 27 1 N.O. / 1N.C 2.5-4A MT-32S-6A 27 1 N.O. / 1N.C. 4-6A MT-32S-8A 27 1 N.O. / 1N.C 5-8A MT-32S-9A 27 1 N.O. / 1N.C. 6-9A MT-32S-10A 27 1 N.O. / 1N.C 7-10A MT-32S-13A 27 1 N.O. / 1N.C. 9-13A MT-32S-18A 27 1 N.O. / 1N.C A MT-32S-22A 27 1 N.O. / 1N.C 16-22A MT-32S-25A 27 1 N.O. / 1N.C A MT-32S-32A 35 1 N.O. / 1N.C 22-32A MT-32S-40A 35 1 N.O. / 1N.C 28-40A MT-63L-36A 48 1 N.O. / 1N.C A MT-63L-40A 48 1 N.O. / 1N.C 28-40A MT-63L-50A 48 1 N.O. / 1N.C A MT-63L-65A 48 1 N.O. / 1N.C A MT-95L-65A 62 1 N.O. / 1N.C A MT-95L-75A 62 1 N.O. / 1N.C 54-75A MT-95L-85A 62 1 N.O. / 1N.C A MT-95L-95A 62 1 N.O. / 1N.C 70-95A MT-95L-100A 75 1 N.O. / 1N.C A MT A N.O. / 1N.C A MT A N.O. / 1N.C A MT A N.O. / 1N.C A MT A N.O. / 1N.C A MT A N.O. / 1N.C A MT A N.O. / 1N.C A MT A N.O. / 1N.C A MT A N.O. / 1N.C A MT A N.O. / 1N.C A MT A N.O. / 1N.C A MT A N.O. / 1N.C A MT A N.O. / 1N.C A Applicable Contactor MC-9B MC-12B MC-18B MC-22B MC-32A MC-40A MC-50A MC-65A MC-75A MC-85A MC-100A MC-130A MC-150A MC-185A MC-225A MC-265A MC-330A MC-400A MC-A MC-630A MC-800A Direct Mounting MT-63 MT-225 MT-95 MT-400 MT-800 MC-40 & MT-32 MC-400 & MT-400 MT-150 To Order Call or Visit factorymation.com

20 Thermal Overload Relays (cont d) 113 Formerly LG Industrial Systems Contactor & Overload Accessories Auxiliary Contact UA-1-11 MMS Direct Adapter DA-95A MMS + Contactor Mounting Unit MU-45 Mechanical Interlock with Aux Contact UR-02 Part Number Price Description Auxiliary Contacts UA Side-mount, 1 N.O. / 1N.C., MC-9 to MC-150 UA Top-mount, 1 N.O. / 1 N.C., MC-9 to MC-150 UA Top-mount, 2 N.O. / 2 N.C., MC-9 to MC-150 UA Top-mount, 4 N.O., MC-9 to MC-150 UA Top-mount, 4 N.C., MC-9 to MC-150 AU Side-mount, 1 N.O. / 1 N.C., MC-185 to MC-800 AU-100E-11 9 Side-mount, 1 N.O. / 1 N.C., MC-185 to MC-800 MMS + Contactor Direct Adapters DA-22HA 8 MMS-32H + MC-9B-22B AC DA-22HD 8 MMS-32H + MC-9B-22B DC DA-32HA 9 MMS-32H + MC-32A-40A AC DA-32HD 9 MMS-32H + MC-32A-40A DC DA-63A 9 MMS-63H + MC-50A to MC-65A AC DA-63D 9 MMS-63H + MC-50A to MC-65A DC DA-95A 10 MMS-100H + MC-75A to MC-100A AC DA-95D 10 MMS-100H + MC-75A to MC-100A DC MMS + Contactor Mounting Unit / Base Plate MU-45 8 MMS-32H + MC-9 to MC-40 (45mm) MU MMS-63H + MC-50 to MC-65 (55mm) MU MMS100H + MC-75 to MC-100 (70mm) Contactor Coil Surge Suppressors US-1 9 MC-9 to MC-150, AC24-48V, Varistor + RC US-2 9 MC-9 to MC-150, AC V, Varistor + RC US-3 9 MC-9 to MC-150, AC V, Varistor + RC US-4 9 MC-9 to MC-150, DC24-48V, Varistor + RC US-5 9 MC-9 to MC-150, DC V, Varistor + RC US-6 9 MC-9 to MC-150, DC V, Varistor + RC US-11 7 MC-9 to MC-150, ACDC24-48V, Varistor US-12 7 MC-9 to MC-150, ACDC V, Varistor US-13 7 MC-9 to MC-150, ACDC V, Varistor US-14 7 MC-9 to MC-150, ACDC V, Varistor US-22 7 MC-9 to MC-150, AC V, RC Overload Remote Reset Kits UM-4R mm cable, MT-12 to MT-95 UM-5R 48 mm cable, MT-12 to MT-95 UM-6R mm cable, MT-12 to MT-95 Overload Separate Mount Units UZ-32S 6 for MT-32S Overload UZ-63L 8 for MT-63L Overload UZ-95L 10 for MT-95L Overload Part Number Price Description Terminal Covers AP Terminal cover (2 pcs), MC-185A to MC-225A (input and output) AP Terminal cover (2 pcs), MC-265A to MC-400A (input and output) AP Terminal cover (2 pcs), MC-A to MC-800A (input and output) APT Terminal cover assembly, MT-225 APT Terminal cover assembly, MT-400 APT Terminal cover assembly, MT-800 Reversing Kits UW Reversing Wire Kit for MC-9 to MC-22 UW Reversing Wire Kit for MC-32 to MC-40 UW Reversing Wire Kit for MC-50 to MC-65 UW Reversing Wire Kit for MC-75 to MC-100 Mechanical Interlocks UR Mechanical Interlock, 2 N.C., MC-9 to MC-150 AR Mechanical Interlock, MC-180A to MC-400A AR Mechanical Interlock, MC-A to MC-800A Reversing Base Plates RBP-180/ Reversing Base Plate Interlock, MC-185A to MC-225A RBP-300/ Reversing Base Plate Interlock, MC-265A to MC-400A Insulation Barriers AI Insulation Barrier (4pcs.), MC-185A to MC-400A AI Insulation Barrier (4pcs.), MC-A to MC-800A Lug Terminals AJ Lug Terminals for MC-185A to MC-225A (3 pcs) AJ Lug Terminals for MC-265A to MC-400A (3 pcs) AJ Lug Terminals for MC-A to MC-800A (3 pcs) Terminal Cover AP-220 Installing Auxiliary Contacts UA-1 UA-2,4 Lug Terminals AJ-220 MOTOR CONTROLS UZ-150S 13 for MT-150 Overload Surge Suppressor US-2 Remote Reset Cable UM-4R O/L Separate Mount UZ-32S (Shown with O/L) To install side-mounting aux contacts remove the indicated part in the circle first. Then fit each part as shown. To separate push forward and pull. To install top-mounting aux contacts position on top of contactor and push down. To separate, pull the lever of the contact block and push upward. ONLINE ORDERS FREESHIPPING SMALL PACKAGES MIN. 29 LTL FREIGHT MIN. SEE INSIDE BACK COVER FOR MORE DETAILS

21 114 Formerly LG Industrial Systems MOTOR CONTROLS Metasol Contactor and Overload Specifications Contactor MC-9B MC-75A MC-A MC-32A MC-50A MC-130A MC-185A MC-265A MC-12B MC-22B MC-85L MC-40A MC-65A MC-150A MC-225A MC-330A MC-400A MC-630A MC-18B MC-100L MC-800A Number of Poles 3 3 pole Rated Operational Voltage, Ue 690V Rated Insulation Voltage, Ui 690V 1000V 1000V 1000V Rated Frequency 60Hz Rated Impulse Withstand Voltage, Uimp 6kV 8kV 8kV 8kV Maximum Operations Per Hour (AC3) Mechanical Durability (Million Operations) Electrical Durability (Million Operations) Auxiliary Contacts (Standard) 1 N.O. / 1 N.C. 2 N.O. / 2 N.C. 2 N.O. / 2 N.C. 2 N.O. / 2 N.C. 2 N.O. / 2 N.C. 2 N.O. / 2 N.C. 2 N.O. / 2 N.C. 2 N.O. / 2 N.C. Thermal Magnetic Overload MT-12 MT-32 MT-32 MT-63 MT-95 MT-150 MT-225 MT-400 MT-800 Rated Operational Voltage, Ue 690V Rated Insulation Voltage, Ui 690V Rated Impulse Withstand Voltage, Uimp 6kV Trip Class 10 Setting Range A A A 4-65A 7-100A A A A A Standards UL File # E / E Coil Current Consumption Part Number AC Coil Control Voltage Voltage Limit Coil 20 C (220V, 60Hz) DC Coil MC-9B to MC-22B MC-32A MC-40A MC-50A MC-65A MC-75A MC-85A MC-100A MC-130A MC-150A 50Hz 24, 120, , 120, 230, 60Hz 24, 120, 208, 230, 480 MC-185A MC-225A 24, , MC-265A MC-400A , , MC-A MC-800A In240, Operational % % % % % % % % Drop-out 30-60% 30-60% 30-60% 30-60% 30-60% 30-60% 30-60% 30-60% Inrush (VA) ,000 Sealed (VA) Control Voltage DC 12, 24 12, 24 12, 24 12, 24 N/A N/A N/A N/A Voltage Limit Current Consumption Dimensions in(mm) D A1 A2 * Mounting plate dimension Operational % % % % N/A N/A N/A N/A Drop-out 10-30% 10-30% 10-30% 10-30% N/A N/A N/A N/A Inrush (W) N/A N/A N/A N/A Sealed (W) N/A N/A N/A N/A B C Metasol Contactor and Overload Dimensions Contactor A1 A2 B C D AC Contactors MC-9 AC MC-18 AC (45mm) 3.44 (87.4mm) 2.89 (73.5mm) 5.11 (129.9mm) MC-22 AC (45mm) 3.39 (86mm) 2.89 (73.5mm) 5.11 (129.9mm) MC-32 AC MC-40 AC 2.72 (69mm) 1.77 (45mm) 3.54 (90mm) 3.27 (83mm) 5.49 (139.4mm) MC-50 AC MC-65 AC 3.11 (79mm) 2.17 (55mm) 4.69 (119mm) 4.17 (106mm) 6.45 (163.8mm) MC-75 AC MC-100 AC 3.70 (94mm) 2.76 (70mm) 5.35 (135.8mm) 5.51 (140mm) 8.32 (211.4mm) MC-130 AC MC-150 AC 4.69"(119mm) 3.74 (95mm*) 5.13 (130.3mm) 6.22 (158mm) 9.30 (236.2mm) MC-185 AC/DC MC-225 AC/DC 6.38 (162mm*) 5.43 (138mm) 7.29"(185.1mm) 7.99 (203mm) (306.5mm*) MC-265 AC/DC MC-400 AC/DC 7.36 (187mm*) 6.42 (163mm) 8.05 (204.4mm) 9.57 (243mm) (380mm*) MC- AC/DC MC-800 AC/DC (360mm*) 11.22(285mm) 9.66 (245.3mm) (312mm) (530mm*) DC Contactors MC-9 DC MC-18 DC (45mm) 4.63 (117.7mm) 2.89 (73.5mm) 5.11 (129.9mm) MC-22 DC (45mm) 4.63 (117.7mm) 2.89 (73.5mm) 5.11 (129.9mm) MC-32 DC MC-40 DC 2.72 (69mm) 1.77 (45mm) 4.73 (120.1mm) 3.27 (83mm) 5.49 (139.4mm) MC-50 DC MC-65 DC 3.11 (79mm) 2.17 (55mm) 5.87 (149.2mm) 4.17 (106mm) 6.45 (163.8mm) MC-75 DC MC-100 DC 3.70 (94mm) 2.76 (70mm) 6.84 (173.8mm) 5.51 (140mm) 8.32 (211.4mm) MC-130 DC MC-150 DC (95mm*) 5.13 (130.3mm) 6.22 (158mm) 9.30 (236.2mm) Optional Auxiliary Contact Specifications Part Number UA-1-11 UA-2-11 UA-2-20 UA-4-22 UA-4-40 AU-100 AU-100E Rated Thermal Current (Ith) AC: 10A AC: 16A AC: 1A AC-15, A600 DC-13, P300 Mechanical Endurance Conductor Size 120V: 6A, 240V: 3A, 380V: 1.9A 480V: 1.5A, V: 1.4A, 600V: 1.2A 125V: 1.1A, 250V:.055A, 400V: 0.31A, V: 0.27A, 600V: 0.2A,000 operations 18AWG - 10AWG AC 24V 0.1A AC 50V 0.01A DC 24V 0.1A DC 50V 0.01A To Order Call or Visit factorymation.com

22 INDUSTRIAL MOTOR CONTROL PANELS 115 CERTIFIED PANEL BUILDER FactoryMation Panel Shop Advantages The FactoryMation Panel Shop can design and fabricate an extensive variety of control panels ranging from small motor starter panels to advanced motor control centers. Our engineers can assist in the development of designs based on customer requirements and/or customer supplied drawings. In-stock components mean even custom panels are completed with industry leading build times. Expert design and component selection Thousands of projects completed per year In-stock components Detailed schematic drawings and component/wire labeling for ease of maintenance and troubleshooting CNC precision cut-outs completed in-house for fast assembly and quick turn-around Quality inspection of each control panel prior to shipment Prompt delivery most standard control panels are assembled and shipped within 3 business days Free technical support and one year parts warranty MOTOR CONTROLS SELECTING A MOTOR STARTER Follow this step-by-step guide to select your custom motor starter: (1) Non-reversing or Reversing Non-reversing motor starters have a single contactor and are designed to run the motor in one direction only. Reversing motor starters use two mechanically interlocked contactors. The use of two contactors makes it possible to run the motor in two directions, forward or reverse, and the interlock prevents energizing both contactors at the same time. (2) Horsepower and FLA Ratings Check your motor nameplate to identify your motor s horsepower and full-load amp (FLA) ratings. Be sure the FLA rating of the motor does not exceed the FLA rating of the motor starter. The thermal overload device should be set to match the motor nameplate amps, not to exceed the FLA rating of the motor starter. If you have questions regarding selection of the motor starter that best fits your application, contact FactoryMation Technical Support. (3) Circuit Protection All of our combination motor starters have a through-the-door disconnect handle with safety lock-out provisions. (4) Input Voltage Select the input voltage of the motor starter. The input voltage should match the voltage used to power the motor. (5) Enclosure Rating Several enclosure options are available to closely match the requirements of your application. The following UL Type environmental ratings are available: ONLINE ORDERS FREESHIPPING SMALL PACKAGES MIN. 29 UL Type 1 - Indoor use primarily to provide a degree of protection against limited amounts of falling dirt. UL Type 12 - Indoor use primarily to provide a degree of protection against circulating dust, falling dirt, and dripping non-corrosive liquids. UL Type 3R - Outdoor use primarily to provide a degree of protection against rain, sleet, and damage from external ice formation. UL Type 4 - Indoor or outdoor use primarily to provide a degree of protection against windblown dust and rain, splashing water, hose-directed water and damage from external ice formation. UL Type 4X - Indoor or outdoor use primarily to provide a degree of protection against corrosion, windblown dust and rain, splashing water, hose-directed water, and damage from external ice formation. (6) Motor Starter Options Control Transformer Select a control transformer when it is desirable to reduce your control voltage for operator devices, pilot lights, and remote control components. Transformer primaries are wired for the same voltage as the motor starter input power. Transformers are available with a 120VAC secondary. Operators Optional operator devices can be selected to offer control from the front panel of the LTL FREIGHT MIN. SEE INSIDE BACK COVER FOR MORE DETAILS motor starter. Operator device control voltage will be equivalent to the input voltage of the starter or the secondary voltage of the optional control transformer. If operators are excluded, the contactor coil can be specified to allow for remote operation of the motor starter. Operator options include: Non-Reversing - Start/Stop Pushbuttons - Hand-Off-Auto Selector Switch Reversing - Forward-Stop-Reverse Pushbuttons - Forward-Off-Reverse Selector Switch No Operators, remote control desired - No operators, 24VAC/60Hz contactor coil - No operators, 120VAC/60Hz contactor coil - No operators, 208VAC/60Hz contactor coil - No operators, 230VAC/60Hz contactor coil - No operators, 480VAC/60Hz contactor coil Pilot Lights Non-Reversing - Pilot Light, ON indication, RED color Reversing - Pilot Lights, 1-FWD and 1-REV indicator, RED color

23 116 PREDESIGNED MOTOR CONTROL PANELS MOTOR CONTROLS Standard motor control panels have predesigned layouts and prebuilt chassis systems. All components used to complete the panel assemblies are stocked in-house. Final assembly is completed in days, not weeks! Pushbutton Stations Combination Motor Starters (1/2-200 hp) Enclosed DOL Motor Starters (1/6-75 hp) MODIFIED/CUSTOM MOTOR CONTROL PANELS FactoryMation is capable of providing modifications to standard control panel designs as well as complete custom design/build control panels. A vast selection of industrial enclosures and controls are in-stock allowing for industry-leading build and delivery times even on custom control panels! Variable Speed AC Drive Panels Pump Controllers Reduced Voltage Starters Bypass Panels Operator Consoles and Panels Enclosed Contactors Fused and Non-Fused Disconnect Switches Circuit Breaker Disconnect Switches Junction/Terminal Boxes SHIPS IN 3 DAYS!* Combination Soft Starter Panels ( hp) *Most standard models can ship within three business days. VIEW IN THE FOLLOWING SECTION! GET A QUOTE RIGHT NOW! PHONE SUPPORT@FACTORYMATION.COM To Order Call or Visit factorymation.com

24 Economy Enclosed DOL Motor Starters Full Voltage Magnetic Motor Starter 117 Dimensional information is available on the last page of this section. Note: Most standard configurations are in stock for same day shipping. 79 TYPE 4X PROTECTION UL Type 4X polymeric enclosure with standard size knockouts START/STOP models pre-wired for 3-wire control with through the cover overload RESET Class 10 overload relays - Class 10 direct heated bimetallic elements Adjustable trip current Ambient temperature compensation Phase-loss protection Selectable manual or automatic reset Electrically isolated N.O./N.C. auxiliary contacts UL508 Listed Assembly Build Your Part Number: Single-Phase Three-Phase Economy Direct-On-Line Motor Starter Non-Reversing Horsepower Motor Voltage EDOLPS - xxxhp - xxxv - N4P - xxxx - xxxx EDOLP - xxxhp - xxxv - N4P - xxxx - xxxx UL Type 4X, Plastic Control Voltage Operator Devices Single-phase Max. UL Ratings Part Number -RSET Operator Devices Reset Only Start/Stop Starter FLA 1 Current Trip Range 2 DIM EDOLPS- HP -RSET -STSR 120V 1/ A 0P2HP-120V-N4P EP / A 0P-120V-N4P EP / A 0P-120V-N4P EP / A OP5HH-120V-N4P EP / A 0P7HP-120V-N4P EP HP-120V-N4P EP / A 1P-120V-N4P EP A* O02HP-120V-N4P EP A V-N4P EP V 1/ A 0P1HP-230V-N4P EP / A 0P-230V-N4P EP / A 0P-230V-N4P EP A 001HP-230V-N4P EP / A 1P-230V-N4P EP A O02HP-230V-N4P EP HH-230V-N4P EP A O0-230V-N4P EP HH-230V-N4P EP A* V-N4P EP / A 007HP-230V-N4P EP STSR MOTOR CONTROLS Control Voltage Options Control/Coil Voltage -LINE 0 Motor Voltage and Control/Coil Voltages are internally connected -X024 0 Externally supplied 24VAC Control/Coil Voltage -X120 0 Externally supplied 120VAC Control/Coil Voltage -X240 0 Externally supplied VAC Control/Coil Voltage -X460 0 Externally supplied 460VAC Control/Coil Voltage Note 1: The actual FLA motor amps may vary from the HP values listed. Motor FLA found on the nameplate must be less than or equal to Starter FLA for proper motor protection. Motor FLA Starter FLA Note 2: Adjustable Overload range exceeds Starter FLA rating. Do not adjust overload setting to exceed starter FLA rating. ONLINE ORDERS FREESHIPPING SMALL PACKAGES MIN. 29 LTL FREIGHT MIN. SEE INSIDE BACK COVER FOR MORE DETAILS

25 118 Economy Enclosed DOL Motor Starters (cont d) Full Voltage Magnetic Motor Starter MOTOR CONTROLS Dimensional information is available on the last page of this section. Build Your Part Number: Single-Phase Three-Phase Economy Direct-On-Line Motor Starter Non-Reversing Horsepower Motor Voltage EDOLPS - xxxhp - xxxv - N4P - xxxx - xxxx EDOLP - xxxhp - xxxv - N4P - xxxx - xxxx UL Type 4X, Plastic Control Voltage Operator Devices Control Voltage Options Control/Coil Voltage -LINE 0 Motor Voltage and Control/Coil Voltages are internally connected -X024 0 Externally supplied 24VAC Control/Coil Voltage -X120 0 Externally supplied 120VAC Control/Coil Voltage -X240 0 Externally supplied VAC Control/Coil Voltage -X460 0 Externally supplied 460VAC Control/Coil Voltage 79 TYPE 4X PROTECTION UL Type 4X polymeric enclosure with standard size knockouts START/STOP models pre-wired for 3-wire control with through the cover overload RESET Class 10 overload relays - Class 10 direct heated bimetallic elements Adjustable trip current Ambient temperature compensation Phase-loss protection Selectable manual or automatic reset Electrically isolated N.O./N.C. auxiliary contacts UL508 Listed Assembly Note: Most standard configurations are in stock for same day shipping. Note 1: The actual FLA motor amps may vary from the HP values listed. Motor FLA found on the nameplate must be less than or equal to Starter FLA for proper motor protection. Motor FLA Starter FLA Note 2: Adjustable Overload range exceeds Starter FLA rating. Do not adjust overload setting to exceed starter FLA rating. Three-phase Max. UL Ratings Part Number -RSET -STSR Operator Devices Reset Only Start/Stop Starter Current FLA 1 Trip Range 2 DIM EDOLP- HP -RSET -STSR 208V 1/ A 0P-208V-N4P EP / A 0P7HP-208V-N4P EP A 001HP-208V-N4P EP A 002HP-208V-N4P EP A 002HH-208V-N4P EP A O0-208V-N4P EP A 003HH-208V-N4P EP A O0-208V-N4P EP A 005HH-208V-N4P EP / A* O07HP-208V-N4P EP A 010HP-208V-N4P EP A V-N4P EP A 015HH-208V-N4P EP A* 020HP-208V-N4P EP A V-N4P EP A* 030HP-208V-N4P EP V 1/ A 0P-230V-N4P EP / A 0P7HP-230V-N4P EP A 001HP-230V-N4P EP A 002HP-230V-N4P EP A O0-230V-N4P EP A 003HH-230V-N4P EP A O0-230V-N4P EP A 005HH-230V-N4P EP / A* O07HP-230V-N4P EP A 010HP-230V-N4P EP A V-N4P EP A 020HP-230V-N4P EP A 020HH-230V-N4P EP A* V-N4P EP A 030HP-230V-N4P EP A 030HH-230V-N4P EP A* 040HP-230V-N4P EP V 1/ A 0P-460V-N4P EP / A 0P7HP-460V-N4P EP A 001HP-460V-N4P EP A 002HP-460V-N4P EP A O0-460V-N4P EP A O0-460V-N4P EP A 005HH-460V-N4P EP / A O07HP-460V-N4P EP A 010HP-460V-N4P EP A 010HH-460V-N4P EP A* V-N4P EP A 020HP-460V-N4P EP A 030HP-460V-N4P EP A 040HP-460V-N4P EP A 040HH-460V-N4P EP A* 050HP-460V-N4P EP A* 060HP-460V-N4P EP A* V-N4P EP To Order Call or Visit factorymation.com

26 Economy Enclosed DOL Motor Starters (cont d) UL Type 1, Non-reversing Product shown in picture includes optional items. Dimensional information is available on the last page of this section. DOL Motor Starters include contactor and thermal overload Single-phase 120V and 230V input voltage models available, 1/ to 10HP Three-phase 208V, 230V, and 460V input voltage models available, 1/2HP to 50HP UL Type 1 listed enclosure Mechanical reset standard All components UL/CUL certified *Most standard models can ship within three business days. Build Your Part Number: Single-Phase Three-Phase Economy Direct-On-Line Motor Starter Non-Reversing Horsepower UL Type Rating Control Voltage Operator Devices Motor Voltage EDOLNRS - xxxhp - xxxv - N01 - xxxx - xxxx EDOLNR - xxxhp - xxxv - N01 - xxxx - xxxx Options (select one of each) Control/Coil Voltage -LINE 0 Motor Voltage and Control/Coil Voltages are internally connected -X024 0 Externally supplied 24VAC Control/Coil Voltage -X120 0 Externally supplied 120VAC Control/Coil Voltage -X208 0 Externally supplied 208VAC Control/Coil Voltage -X230 0 Externally supplied 230VAC Control/Coil Voltage -X460 0 Externally supplied 460VAC Control/Coil Voltage Operator Devices -RSET 0 Reset Pushbutton Only -SSTR 25 Start/Stop and Reset Pushbuttons -HOAP 25 -STHR UP TO 50HP SHIPS IN 3 DAYS!* Hand-Off-Auto Selector Switch and Reset Pushbutton Start/Stop, Hand-Off-Auto Selector Switch, and Reset Pushbutton Single-phase 120V 1/ A 0P-120V ED / A 0P-120V ED / A 0P7HP-120V ED A O01HP-120V ED / A 1P-120V ED A O02HP-120V ED A O0-120V ED V 1/ A 0P-230V ED / A 0P7HP-230V ED A O01HP-230V ED / A 1P-230V ED A O02HP-230V ED A O0-230V ED A O0-230V ED / A O07HP-230V ED A 010HP-230V ED2 334 Three-phase Part Number UL Type 1 Max. UL Ratings Current -N01 Trip Range EDOLNRS- HP FLA DIM Price Part Number UL Type 1 Max. UL Ratings Current -N01 Trip Range EDOLNR- HP FLA DIM Price 208V 1/ A 0P-208V ED A 001HP-208V ED / A 1P-208V ED A 002HP-208V ED A O0-208V ED A O0-208V ED / A O07HP-208V ED A 010HP-208V ED A V ED A 020HP-208V ED A V ED A 030HP-208V ED V 3/ A 0P7HP-230V ED A 001HP-230V ED / A 1P-230V ED A 002HP-230V ED A O0-230V ED A O0-230V ED / A O07HP-230V ED A 010HP-230V ED A V ED A 020HP-230V ED A V ED A 030HP-230V ED A 040HP-230V ED V 1/ A 0P-460V ED A 001HP-460V ED / A 1P-460V ED A 002HP-460V ED A O0-460V ED A O0-460V ED / A O07HP-460V ED A 010HP-460V ED A V ED A 020HP-460V ED A 030HP-460V ED A 040HP-460V ED A 050HP-460V ED A 060HP-460V ED A V ED MOTOR CONTROLS -SSTR -HOAP -STHR ONLINE ORDERS FREESHIPPING SMALL PACKAGES MIN. 29 LTL FREIGHT MIN. SEE INSIDE BACK COVER FOR MORE DETAILS

27 120 Enclosed DOL Motor Starters MOTOR CONTROLS Direct-On-Line, Non-reversing Product shown in picture includes optional items. Dimensional information is available on the last page of this section. DOL Motor Starters include contactor and thermal overload Single-phase 120V and 230V input voltage models available, 1/6HP to 10HP Hinged, UL Type rated enclosure Mechanical reset standard All components UL/CUL certified *Most standard models can ship within three business days. Build Your Part Number: Direct-On-Line Motor Starter Non-Reversing Horsepower DOLNRS - xxxhp - xxxv - Nxx - xxxx - xxxx UL Type Rating Control Voltage Operator Devices Options (select one of each) -LINE 0 Motor Voltage Control/Coil Voltage Motor Voltage and Control/Coil Voltages are internally connected -X024 0 Externally supplied 24VAC Control/Coil Voltage -X120 0 Externally supplied 120VAC Control/Coil Voltage Operator Devices -RSET 0 Reset Pushbutton Only -STSR 50 Start-Stop/Reset Pushbuttons -HOAS 50 Hand-Off-Auto Selector Switch and Reset Pushbutton 207 UP TO 10HP SHIPS IN 3 DAYS!* 120V, Single-phase Max. UL Ratings Current Trip Range 230V, Single-phase Part Number UL Type 4/12 UL Type 4X UL Type 4XSS 1/ A 0P1HP-120V EN1 207 PC1 218 SS / A 0P2HP-120V EN1 207 PC1 218 SS / A 0P-120V EN1 207 PC1 218 SS / A 0P-120V EN1 207 PC1 218 SS / A 0P7HP-120V EN1 228 PC1 239 SS A 001HP-120V EN1 228 PC1 239 SS / A 1P-120V EN1 228 PC1 239 SS A 002HP-120V EN2 311 PC1 322 SS A V EN2 311 PC1 322 SS A V EN2 311 PC1 322 SS V, Single-phase -N04 -N4P -NSS DOLNRS- HP FLA DIM Price DIM Price DIM Price Max. UL Current Part Number UL Type 4/12 UL Type 4X UL Type 4XSS Ratings Trip -N04 -N4P -NSS Range DOLNRS- HP FLA DIM Price DIM Price DIM Price 1/ A 0P1HP-208V EN1 207 PC1 218 SS / A 0P2HP-208V EN1 207 PC1 218 SS / A 0P-208V EN1 207 PC1 218 SS / A 0P-208V EN1 207 PC1 218 SS / A 0P7HP-208V EN1 207 PC1 218 SS A 001HP-208V EN1 228 PC1 239 SS / A 1P-208V EN1 228 PC1 239 SS A 002HP-208V EN1 311 PC1 322 SS A V EN1 311 PC1 322 SS A V EN2 311 PC1 322 SS / A 007HP-208V EN2 311 PC1 322 SS A 010HP-208V EN2 415 PC1 436 SS2 603 Max. UL Ratings Current Trip Range Part Number UL Type 4/12 UL Type 4X UL Type 4XSS -N04 -N4P -NSS DOLNRS- HP FLA DIM Price DIM Price DIM Price 1/ A 0P1HP-230V EN1 207 PC1 218 SS / A 0P2HP-230V EN1 207 PC1 218 SS / A 0P-230V EN1 207 PC1 218 SS / A 0P-230V EN1 207 PC1 218 SS / A 0P7HP-230V EN1 207 PC1 218 SS A 001HP-230V EN1 228 PC1 239 SS / A 1P-230V EN1 228 PC1 239 SS A 002HP-230V EN1 311 PC1 322 SS A V EN1 311 PC1 322 SS A V EN2 311 PC1 322 SS / A 007HP-230V EN2 311 PC1 322 SS A 010HP-230V EN2 415 PC1 436 SS2 603 Selection QueStionS? Our motor starters are custom-built to customer specifications. If you need assistance selecting a motor starter, contact FactoryMation Technical To Order Call or Visit factorymation.com

28 Enclosed DOL Motor Starters (cont d) Direct-On-Line, Non-reversing Product shown in picture includes optional items. Dimensional information is available on the last page of this section. DOL Motor Starters include contactor and thermal overload Three-phase 208V, 230V, and 460V input voltage models available, 1/2HP to 7 Hinged, UL Type-rated enclosure Mechanical reset standard All components UL/CUL certified *Most standard models can ship within three business days. Build Your Part Number: Direct-On-Line Motor Starter Non-Reversing Horsepower Motor Voltage DOLNR - xxxhp - xxxv - Nxx - xxxx - xxxx UL Type Rating Control Voltage Operator Devices Options (select one of each) Control/Coil Voltage -LINE 0 Motor Voltage and Control/Coil Voltages are internally connected -X024 0 Externally supplied 24VAC Control/Coil Voltage -X120 0 Externally supplied 120VAC Control/Coil Voltage -X208 0 Externally supplied 208VAC Control/Coil Voltage -X230 0 Externally supplied 230VAC Control/Coil Voltage Operator Devices -RSET 0 Reset Pushbutton Only -STSR 50 Start-Stop/Reset Pushbuttons -HOAS 50 Hand-Off-Auto Selector Switch and Reset Pushbutton 207 UP TO 7 SHIPS IN 3 DAYS!* 208V, Three-phase 230V, Three-phase 460V, Three-phase Max. UL Part Number UL Type 4/12 UL Type 4X UL Type 4XSS Ratings Current -N04 -N4P -NSS Trip Range DOLNR- HP FLA DIM Price DIM Price DIM Price 1/ A 0P-208V EN1 207 PC1 218 SS / A 0P7HP-208V EN1 207 PC1 218 SS A 001HP-208V EN1 207 PC1 218 SS / A 1P-208V EN1 207 PC1 218 SS A 002HP-208V EN1 207 PC1 218 SS A V EN1 207 PC1 218 SS A V EN1 228 PC1 239 SS / A 007HP-208V EN1 228 PC1 239 SS A 010HP-208V EN2 311 PC1 322 SS A V EN2 311 PC1 322 SS A 020HP-208V EN2 311 PC1 322 SS A V EN3 415 PC1 322 SS A 030HP-208V EN3 415 PC2 436 SS3 603 Max. UL Part Number UL Type 4/12 UL Type 4X UL Type 4XSS Ratings Current -N04 -N4P -NSS Trip Range DOLNR- HP FLA DIM Price DIM Price DIM Price 1/ A 0P-230V EN1 207 PC1 218 SS / A 0P7HP-230V EN1 207 PC1 218 SS A 001HP-230V EN1 207 PC1 218 SS / A 1P-230V EN1 207 PC1 218 SS A 002HP-230V EN1 207 PC1 218 SS A V EN1 207 PC1 218 SS A V EN1 228 PC1 239 SS / A 007HP-230V EN1 228 PC1 239 SS A 010HP-230V EN2 311 PC1 322 SS A V EN2 311 PC1 322 SS A 020HP-230V EN2 311 PC1 322 SS A V EN3 415 PC1 322 SS A 030HP-230V EN3 415 PC2 436 SS3 603 Max. UL Part Number UL Type 4/12 UL Type 4X UL Type 4XSS Ratings Current -N04 -N4P -NSS Trip Range DOLNR- HP FLA DIM Price DIM Price DIM Price 1/ A 0P-460V EN1 207 PC1 218 SS / A 0P7HP-460V EN1 207 PC1 218 SS A 001HP-460V EN1 207 PC1 218 SS / A 1P-460V EN1 207 PC1 218 SS A 002HP-460V EN1 207 PC1 218 SS A V EN1 207 PC1 218 SS A V EN1 207 PC1 218 SS / A 007HP-460V EN1 207 PC1 218 SS A 010HP-460V EN1 228 PC1 239 SS A V EN1 228 PC1 239 SS A 020HP-460V EN1 228 PC1 239 SS A V EN2 311 PC1 322 SS A 030HP-460V EN2 311 PC1 322 SS A 040HP-460V EN2 311 PC1 322 SS A 050HP-460V EN2 311 PC1 322 SS A 060HP-460V EN3 415 PC2 436 SS A V EN3 415 PC2 436 SS MOTOR CONTROLS ONLINE ORDERS FREESHIPPING SMALL PACKAGES MIN. 29 LTL FREIGHT MIN. SEE INSIDE BACK COVER FOR MORE DETAILS

29 122 MOTOR CONTROLS Economy Combination Motor Starters Non-reversing Dimensional information is available on the last page of this section. Manual Motor Starter with disconnect handle: power disconnect + circuit protection 208V, 230V, and 460V input voltage models up to 7 Enclosure choices that meet your application requirements *Most standard models can ship within three business days. Build Your Part Number: Economy Combination Motor Starter Non-Reversing Horsepower Disconnect Type ECMSNR - xxxhp - MP - xxxv - N4P xxxx - 00 UL Type Rating Control Transformer Operator Devices Pilot Light Options (select one of each) None Control Transformer Operator Devices -STSP 50 Start-Stop Pushbuttons -HOAS 50 Hand-Off-Auto Selector Switch Motor Voltage -N024 0 No operators, 24VAC/60Hz Coil for remote op -N120 0 No operators, 120VAC/60Hz Coil for remote op -N208 0 No operators, 208VAC/60Hz Coil for remote op -N230 0 No operators, 230VAC/60Hz Coil for remote op -N460 0 No operators, 480VAC/60Hz Coil for remote op None Pilot Lights 311 UP TO 7 SHIPS IN 3 DAYS!* 208V, Three-phase 230V, Three-phase 460V, Three-phase Part Number UL Type 4X Max. UL Ratings Current -N4P Trip Range ECMSNR- HP FLA DIM Price 1/ A 0P-MP-208V PC / A 0P7HP-MP-208V PC A 001HP-MP-208V PC / A 1P-MP-208V PC A 002HP-MP-208V PC A 00-MP-208V PC A 00-MP-208V PC / A 007HP-MP-208V PC A 010HP-MP-208V PC A 01-MP-208V PC A 020HP-MP-208V PC A 02-MP-208V PC A 030HP-MP-208V PC3 675 Part Number UL Type 4X Max. UL Ratings Current -N4P Trip Range ECMSNR- HP FLA DIM Price 1/ A 0P-MP-230V PC / A 0P7HP-MP-230V PC A 001HP-MP-230V PC / A 1P-MP-230V PC A 002HP-MP-230V PC A 00-MP-230V PC A 00-MP-230V PC / A 007HP-MP-230V PC A 010HP-MP-230V PC A 01-MP-230V PC A 020HP-MP-230V PC A 02-MP-230V PC A 030HP-MP-230V PC3 675 Part Number UL Type 4X Max. UL Ratings Current -N4P Trip Range ECMSNR- HP FLA DIM Price 1/ A 0P-MP-460V PC A 001HP-MP-460V PC / A 1P-MP-460V PC A 002HP-MP-460V PC A 00-MP-460V PC A 00-MP-460V PC / A 007HP-MP-460V PC A 010HP-MP-460V PC A 01-MP-460V PC A 020HP-MP-460V PC A 02-MP-460V PC A 030HP-MP-460V PC A 040HP-MP-460V PC A 050HP-MP-460V PC A 060HP-MP-460V PC A 07-MP-460V PC3 675 To Order Call or Visit factorymation.com

30 Economy Combination Motor Starters (cont d) Reversing Dimensional information is available on the last page of this section. Manual Motor Starter with disconnect handle: power disconnect + circuit protection 208V, 230V, and 460V input voltage models up to 7 Enclosure choices that meet your application requirements *Most standard models can ship within three business days. Build Your Part Number: Economy Combination Motor Starter Reversing Options (select one of each) None Control Transformer Operator Devices Pilot Lights -FSRV 75 Forward-Stop-Reverse Pushbuttons -FORV 75 Forward-Off-Reverse Selector Switch -N024 0 No operators, 24VAC/60Hz Coil for remote op -N120 0 No operators, 120VAC/60Hz Coil for remote op -N208 0 No operators, 208VAC/60Hz Coil for remote op -N230 0 No operators, 230VAC/60Hz Coil for remote op -N460 0 No operators, 480VAC/60Hz Coil for remote op None Pilot Lights 415 UP TO 7 SHIPS IN 3 DAYS!* 208V, Three-phase 1/ A 0P-MP-208V PC / A 0P7HP-MP-208V PC A 001HP-MP-208V PC / A 1P-MP-208V PC A 002HP-MP-208V PC A 00-MP-208V PC A 00-MP-208V PC / A 007HP-MP-208V PC A 010HP-MP-208V PC A 01-MP-208V PC A 020HP-MP-208V PC A 02-MP-208V PC A 030HP-MP-208V PC V, Three-phase 1/ A 0P-MP-230V PC / A 0P7HP-MP-230V PC A 001HP-MP-230V PC / A 1P-MP-230V PC A 002HP-MP-230V PC A 00-MP-230V PC A 00-MP-230V PC / A 007HP-MP-230V PC A 010HP-MP-230V PC A 01-MP-230V PC A 020HP-MP-230V PC A 02-MP-230V PC A 030HP-MP-230V PC V, Three-phase Part Number UL Type 4X Max. UL Ratings Current -N4P Trip Range ECMSRV- HP FLA DIM Price Part Number UL Type 4X Max. UL Ratings Current -N4P Trip Range ECMSRV- HP FLA DIM Price Part Number UL Type 4X Max. UL Ratings Current -N4P Trip Range ECMSRV- HP FLA DIM Price 1/ A 0P-MP-460V PC A 001HP-MP-460V PC / A 1P-MP-460V PC A 002HP-MP-460V PC A 00-MP-460V PC A 00-MP-460V PC / A 007HP-MP-460V PC A 010HP-MP-460V PC A 01-MP-460V PC A 020HP-MP-460V PC A 02-MP-460V PC A 030HP-MP-460V PC A 040HP-MP-460V PC A 050HP-MP-460V PC A 060HP-MP-460V PC A 07-MP-460V PC MOTOR CONTROLS ONLINE ORDERS FREESHIPPING SMALL PACKAGES MIN. 29 LTL FREIGHT MIN. SEE INSIDE BACK COVER FOR MORE DETAILS

31 124 MOTOR CONTROLS Combination Motor Starters Non-reversing Dimensional information is available on the last page of this section. Manual Motor Starter with disconnect handle: power disconnect + circuit protection 208V, 230V, and 460V input voltage models up to 7 Enclosure choices that meet your application requirements *Most standard models can ship within three business days. Build Your Part Number: Combination Motor Starter Non-Reversing Horsepower Disconnect Type CMSNR - xxxhp - MP - xxxv- Nxx - 120XF - xxxx - PL UL Type Rating Control Transformer Operator Devices Pilot Light Options (select one of each) Control Transformer Motor Voltage -120XF 0 Primary same as input voltage, 120V Secondary Operator Devices -STSP 0 Start-Stop Pushbuttons -HOAS 0 Hand-Off-Auto Selector Switch Pilot Lights -PL 0 Pilot light, RED, indicates when starter is ON 519 UP TO 7 SHIPS IN 3 DAYS!* 208V, Three-phase Max. UL Part Number UL Type 4/12 UL Type 4X UL Type 3R UL Type 4XSS Ratings Current -N04 -N4X -N3R -NSS Trip Range CMSNR- HP FLA DIM Price DIM Price DIM Price DIM Price Max. UL Part Number UL Type 4/12 UL Type 4X UL Type 3R UL Type 4XSS Ratings Current -N04 -N4X -N3R -NSS Trip Range CMSNR- HP FLA DIM Price DIM Price DIM Price DIM Price 1/ A 0P-MP-208V EL1 519 U1 571 R1 519 S / A 0P7HP-MP-208V EL1 519 U1 571 R1 519 S A 001HP-MP-208V EL1 519 U1 571 R1 519 S / A 1P-MP-208V EL1 519 U1 571 R1 519 S A 002HP-MP-208V EL1 519 U1 571 R1 519 S A 00-MP-208V EL1 519 U1 571 R1 519 S A 00-MP-208V EL1 519 U1 571 R1 519 S / A 007HP-MP-208V EL1 519 U1 571 R1 519 S A 010HP-MP-208V EL1 675 U1 779 R1 675 S1 1, A 01-MP-208V EL2 675 U2 779 R2 675 S2 1, A 020HP-MP-208V EL2 675 U2 779 R2 675 S2 1, A 02-MP-208V EL3 883 U3 1,091 R3 883 S3 1, A 030HP-MP-208V EL3 883 U3 1,091 R3 883 S3 1, V, Three-phase 1/ A 0P-MP-230V EL1 519 U1 571 R1 519 S / A 0P7HP-MP-230V EL1 519 U1 571 R1 519 S A 001HP-MP-230V EL1 519 U1 571 R1 519 S / A 1P-MP-230V EL1 519 U1 571 R1 519 S A 002HP-MP-230V EL1 519 U1 571 R1 519 S A 00-MP-230V EL1 519 U1 571 R1 519 S A 00-MP-230V EL1 519 U1 571 R1 519 S / A 007HP-MP-230V EL1 519 U1 571 R1 519 S A 010HP-MP-230V EL1 519 U1 571 R1 519 S A 01-MP-230V EL2 675 U2 779 R2 675 S2 1, A 020HP-MP-230V EL2 675 U2 779 R2 675 S2 1, A 02-MP-230V EL3 883 U3 1,091 R3 883 S3 1, A 030HP-MP-230V EL3 883 U3 1,091 R3 883 S3 1, V, Three-phase Max. UL Part Number UL Type 4/12 UL Type 4X UL Type 3R UL Type 4XSS Ratings Current -N04 -N4X -N3R -NSS Trip Range CMSNR- HP FLA DIM Price DIM Price DIM Price DIM Price 1/ A 0P-MP-460V EL1 519 U1 571 R1 519 S A 001HP-MP-460V EL1 519 U1 571 R1 519 S / A 1P-MP-460V EL1 519 U1 571 R1 519 S A 002HP-MP-460V EL1 519 U1 571 R1 519 S A 00-MP-460V EL1 519 U1 571 R1 519 S A 00-MP-460V EL1 519 U1 571 R1 519 S / A 007HP-MP-460V EL1 519 U1 571 R1 519 S A 010HP-MP-460V EL1 519 U1 571 R1 519 S A 01-MP-460V EL1 519 U1 571 R1 519 S A 020HP-MP-460V EL1 519 U1 571 R1 519 S A 02-MP-460V EL2 675 U2 779 R2 675 S2 1, A 030HP-MP-460V EL2 675 U2 779 R2 675 S2 1, A 040HP-MP-460V EL2 675 U2 779 R2 675 S2 1, A 050HP-MP-460V EL3 883 U3 1,091 R3 883 S3 1, A 060HP-MP-460V EL3 883 U3 1,091 R3 883 S3 1, A 07-MP-460V EL3 883 U3 1,091 R3 883 S3 1,351 To Order Call or Visit factorymation.com

32 Combination Motor Starters (cont d) Reversing Dimensional information is available on the last page of this section. Manual Motor Starter with disconnect handle: power disconnect + circuit protection 208V, 230V, and 460V input voltage models up to 7 Enclosure choices that meet your application requirements *Most standard models can ship within three business days. Build Your Part Number: Combination Motor Starter Reversing Horsepower Disconnect Type CMSRV - xxxhp - MP - xxxv- Nxx - 120XF- xxxx - PL2 UL Type Rating Control Transformer Operator Devices Pilot Lights Options (select one of each) Control Transformer Motor Voltage -120XF 0 Primary same as input voltage, 120V Secondary Operator Devices -FSRV 0 Forward-Stop-Reverse Pushbuttons -FORV 0 Forward-Off-Reverse Selector Switch Pilot Lights -PL2 0 Pilot lights, 1-FWD, 1-REV 623 UP TO 7 SHIPS IN 3 DAYS!* 208V, Three-phase 1/ A 0P-MP-208V EL1 623 U1 675 R1 623 S / A 0P7HP-MP-208V EL1 623 U1 675 R1 623 S A 001HP-MP-208V EL1 623 U1 675 R1 623 S / A 1P-MP-208V EL1 623 U1 675 R1 623 S A 002HP-MP-208V EL1 623 U1 675 R1 623 S A 00-MP-208V EL1 623 U1 675 R1 623 S A 00-MP-208V EL1 623 U1 675 R1 623 S / A 007HP-MP-208V EL1 623 U1 675 R1 623 S A 010HP-MP-208V EL1 831 U1 935 R1 831 S1 1, A 01-MP-208V EL2 831 U2 935 R2 831 S2 1, A 020HP-MP-208V EL2 831 U2 935 R2 831 S2 1, A 02-MP-208V EL3 1,039 U4 1,247 R3 1,039 S3 1, A 030HP-MP-208V EL3 1,039 U4 1,247 R3 1,039 S3 1, V, Three-phase 1/ A 0P-MP-230V EL1 623 U1 675 R1 623 S / A 0P7HP-MP-230V EL1 623 U1 675 R1 623 S A 001HP-MP-230V EL1 623 U1 675 R1 623 S / A 1P-MP-230V EL1 623 U1 675 R1 623 S A 002HP-MP-230V EL1 623 U1 675 R1 623 S A 00-MP-230V EL1 623 U1 675 R1 623 S A 00-MP-230V EL1 623 U1 675 R1 623 S / A 007HP-MP-230V EL1 623 U1 675 R1 623 S A 010HP-MP-230V EL1 623 U1 675 R1 623 S A 01-MP-230V EL2 831 U2 935 R2 831 S2 1, A 020HP-MP-230V EL2 831 U2 935 R2 831 S2 1, A 02-MP-230V EL3 1,039 U4 1,247 R3 1,039 S3 1, A 030HP-MP-230V EL3 1,039 U4 1,247 R3 1,039 S3 1, V, Three-phase Max. UL Part Number UL Type 4/12 UL Type 4X UL Type 3R UL Type 4XSS Ratings Current -N04 -N4X -N3R -NSS Trip Range CMSRV- HP FLA DIM Price DIM Price DIM Price DIM Price Max. UL Part Number UL Type 4/12 UL Type 4X UL Type 3R UL Type 4XSS Ratings Current -N04 -N4X -N3R -NSS Trip Range CMSRV- HP FLA DIM Price DIM Price DIM Price DIM Price Max. UL Part Number UL Type 4/12 UL Type 4X UL Type 3R UL Type 4XSS Ratings Current -N04 -N4X -N3R -NSS Trip Range CMSRV- HP FLA DIM Price DIM Price DIM Price DIM Price 1/ A 0P-MP-460V EL1 623 U1 675 R1 623 S A 001HP-MP-460V EL1 623 U1 675 R1 623 S / A 1P-MP-460V EL1 623 U1 675 R1 623 S A 002HP-MP-460V EL1 623 U1 675 R1 623 S A 00-MP-460V EL1 623 U1 675 R1 623 S A 00-MP-460V EL1 623 U1 675 R1 623 S / A 007HP-MP-460V EL1 623 U1 675 R1 623 S A 010HP-MP-460V EL1 623 U1 675 R1 623 S A 01-MP-460V EL1 623 U1 675 R1 623 S A 020HP-MP-460V EL1 623 U1 675 R1 623 S A 02-MP-460V EL1 831 U1 935 R1 831 S1 1, A 030HP-MP-460V EL2 831 U2 935 R2 831 S2 1, A 040HP-MP-460V EL2 831 U2 935 R2 831 S2 1, A 050HP-MP-460V EL3 1,039 U4 1,247 R3 1,039 S3 1, A 060HP-MP-460V EL3 1,039 U4 1,247 R3 1,039 S3 1, A 07-MP-460V EL3 1,039 U4 1,247 R3 1,039 S3 1, MOTOR CONTROLS ONLINE ORDERS FREESHIPPING SMALL PACKAGES MIN. 29 LTL FREIGHT MIN. SEE INSIDE BACK COVER FOR MORE DETAILS

33 126 Combination Motor Starters (cont d) QUICKLY LINK TO OUR PRODUCTS ONLINE MOTOR CONTROLS Combination Starter with Thermal Magnetic Circuit Breaker cmsnr-cb Combination Starter with Fusible Disconnect 671 UP TO 200HP SHIPS IN 3 DAYS!* MCCB with disconnect handle: power disconnect + circuit protection 208V, 230V, and 460V input voltage models up to 200HP Enclosure choices that meet your application requirements *Built to order. Most standard models can ship within three business days. 578 UP TO 200HP SHIPS IN 3 DAYS!* Fusible disconnect: power disconnect + circuit protection Disconnects accept J-type fuses (power fuses not provided) 208V, 230V, and 460V input voltage models up to 200HP Enclosure choices that meet your application requirements *Built to order. Most standard models can ship within three business days. Dimensional information is available on the last page of this section. Reversing Combination Starter with Thermal Magnetic Circuit Breaker cmsrv-cb 848 UP TO 200HP Reversing Combination Starter with Fusible Disconnect 723 UP TO 200HP SHIPS IN 3 DAYS!* MCCB with disconnect handle: power disconnect + circuit protection 208V, 230V, and 460V input voltage models up to 200HP Enclosure choices that meet your application requirements *Built to order. Most standard models can ship within three business days. SHIPS IN 3 DAYS!* Fusible disconnect: power disconnect + circuit protection Disconnects accept J-type fuses (power fuses not provided) 208V, 230V, and 460V input voltage models up to 200HP Enclosure choices that meet your application requirements *Built to order. Most standard models can ship within three business days. cmsnr-fd cmsrv-fd Combination Soft Starter Modified/Custom Motor Control Panels 1,534 UP TO 1200HP 5 to 1200 HP 230 or 460VAC UL Type 1/12, 3R, 4 (optional rain shield) Multiple configuration options available Features Variable Speed AC Drive Panels Pump Controllers Reduced Voltage Starters And More! cssw custom-control-panels To Order Call or Visit factorymation.com

29 $ Manual Motor Starters FREESHIPPING. MOTOR CONTROLS 25. Features: MMS-32H Frame. MMS-63H Frame.

29 $ Manual Motor Starters FREESHIPPING.  MOTOR CONTROLS 25. Features: MMS-32H Frame. MMS-63H Frame. www.factorymation.com/motorcontrols MOTOR CONTROLS 25 Manual Motor Starters High interrupt capacity Din rail and surface mounting Lockable handle (OFF position) IP20 finger safe terminals Class 10 thermal

More information

Mini Contactors & Overloads

Mini Contactors & Overloads 108 Mini s & Overloads GMC-12M Surface or DIN rail mountable UL508 compliant 1/ to 7-1/ 50/60Hz AC and DC versions available Direct-mounting overloads RoHS compliant Auxiliary contacts standard (1 N.0.)

More information

WEG Contactors - CWM and CWME Series

WEG Contactors - CWM and CWME Series Inside (877) 789 Fax () 87 WEG Contactors CWM and CWME Series International () 07 The CWM generalpurpose contactor line has been designed taking into consideration industrial duty and reliability in mind.

More information

J7MN. Ordering Information. Motor Protection Circuit Breaker. Model Number Legend. MPCB system. Options. Motor Protection Circuit Breaker J7MN I-1

J7MN. Ordering Information. Motor Protection Circuit Breaker. Model Number Legend. MPCB system. Options. Motor Protection Circuit Breaker J7MN I-1 Motor Protection Circuit Breaker J7MN ) MPCB system Rotary and switch types Rated operational current 32 A, 63 A and 00 A Switching capacity up to 00 ka/400 V Fixed short-circuit release = 3 x I u Overload

More information

1492-SP Supplementary Protectors

1492-SP Supplementary Protectors Dual terminals provide wiring/bus bar flexibility and clamp from both sides to improve connection reliability Approval marks are easily visible on dome Terminal design helps prevent wiring misses Scratch-

More information

OVERLOAD RELAYS POWER & ACTUATION PROVEN. series

OVERLOAD RELAYS POWER & ACTUATION PROVEN. series POWER & ACTUATION OVERLOAD RELAYS series Need reliable, accurate overload and phase-loss protection for your motors? c3controls Series Bimetallic Overload Relays provide unmatched protection and can be

More information

CS8 Industrial Control Relays

CS8 Industrial Control Relays CS8 Industrial Control Relays Despite increasing complexity, control systems and installations must become increasingly compact. And the CS8 Miniature Relay System packs maximum performance into minimum

More information

TeSys IEC Contactors and Overload Relays

TeSys IEC Contactors and Overload Relays TeSys IEC Contactors and Overload Relays Making High-Fault Short-Circuit Current Ratings Simple Schneider Electric is an industry leader in IEC contactors and overload relays, and is recognized as the

More information

FAZ Supplementary Protectors, FAZ Miniature Circuit Breakers, P2 Disconnect Switches Overview

FAZ Supplementary Protectors, FAZ Miniature Circuit Breakers, P2 Disconnect Switches Overview FAZ Supplementary Protectors, FAZ Miniature Circuit Breakers, P2 Disconnect Switches Overview Supplementary Protectors / Miniature Circuit Breakers Page System overview 10/003 10/001 Supplementary protectors

More information

Circuit Breakers, Type CTI 25M, CTI 45MB, CTI 100

Circuit Breakers, Type CTI 25M, CTI 45MB, CTI 100 MAKING MODERN LIVING POSSIBLE Data sheet Circuit Breakers, Type CTI 25M, CTI 45MB, CTI 100 Circuit breakers for short circuit and overload protection of motor applications cover together with the circuit

More information

Approved Standards. Motor Protection Circuit Breaker (MPCB) J7MN. MPCB system (motor protection CLASS 10) Auxiliary contact modules.

Approved Standards. Motor Protection Circuit Breaker (MPCB) J7MN. MPCB system (motor protection CLASS 10) Auxiliary contact modules. Motor Protection Circuit Breaker (MPCB) J7MN MPCB system (motor protection CLSS 0) Rotary and switch types Rated operational current = 2, 25, 50 and 00 Switching capacity up to 2.5 = 00 k/400 V Fixed short-circuit

More information

Issued February DATA SHEET 5SX2 MCB. Based on Siemens Industrial Control Catalog

Issued February DATA SHEET 5SX2 MCB. Based on Siemens Industrial Control Catalog Issued February 2011 DATA SHEET 5SX2 MCB Based on Siemens Industrial Control Catalog General Data Trip characteristics Tripping characteristics acc. to EN 60 898 Tripping characteristic A, -5 Type A characteristic

More information

Circuit Breakers Type CTI 25M, CTI 45MB

Circuit Breakers Type CTI 25M, CTI 45MB Data sheet Circuit Breakers Type CTI 25M, CTI 45MB Circuit breakers for short circuit and overload protection of motor applications cover the current range 0.1 45 A (AC-3 rating). The product range is

More information

Micro Contactor MA Series

Micro Contactor MA Series Relay-sized contactor, making it the world s smallest >3mm contact clearance acc. to IEC 60335-1 for Safety Applications Reversing contactor with mechanical interlock 3 Pole and 1 Aux. Contact NO or NC

More information

Protection Equipment

Protection Equipment Protection Equipment Price groups 41B, 41E, 41F, 41G, 41H, 41J, 42F, 42J, 143, 401 /2 Introduction Motor starter protectors/ circuit breakers SIRIUS 3RV2 motor starter protectors up to 40 A / General data

More information

Mini Contactors. Mini Contactor Relays 4-pole 20 Auxiliary Contact Blocks. Interface Contactor Relays. Mini Contactors 22 Auxiliary Contact Blocks

Mini Contactors. Mini Contactor Relays 4-pole 20 Auxiliary Contact Blocks. Interface Contactor Relays. Mini Contactors 22 Auxiliary Contact Blocks Mini Contactors Mini Contactor Relays 4-pole 20 Auxiliary Contact Blocks Interface Contactor Relays Mini Contactors 22 Auxiliary Contact Blocks Mini Contactors With Fast On Tab Connectors 24 Mini Contactors

More information

Motor protection circuit breakers

Motor protection circuit breakers Wide adjustment range 0. to 00A IEC breaking capacity Icu 50kA (400V) up to 00A Suitable for isolation Comprehensive line of accessories Magnetic-only version Automatic trip indicators High reliability

More information

Motor protection relays

Motor protection relays Thermal overload relays for currents between 0.09 and 420A Electronic thermal overload relays for currents between 0.4 and A Electronic thermal overload relays with selectable tripping class: 5--20-30

More information

3 Pole Contactors with AC operating coils

3 Pole Contactors with AC operating coils 1 3 Pole Contactors with AC operating coils Characteristics General Characteristics Switching Current 9A ~ Rated insulation voltage (Ui) (Conforming to IEC 158-1) V 750 IEC 60947-4 V 1000 Conforming to

More information

ST 200 M data sheet System pro M compact miniature circuit breakers for supplementary protection acc. to UL 1077

ST 200 M data sheet System pro M compact miniature circuit breakers for supplementary protection acc. to UL 1077 MINIATURE CIRCUIT BREAKERS ST 200 M data sheet System pro M compact miniature circuit breakers for supplementary protection acc. to UL 1077 The ST 200 M miniature circuit breaker provides supplementary

More information

MG24434 Supplementary Protector SUPPLEMENTARY PROTECTOR, 240VAC, 16A, CIRCUIT BREAKER TYPE: STANDARD

MG24434 Supplementary Protector SUPPLEMENTARY PROTECTOR, 240VAC, 16A, CIRCUIT BREAKER TYPE: STANDARD United States MG24434 Supplementary Protector SUPPLEMENTARY PROTECTOR, 240VAC, 16A, CIRCUIT BREAKER TYPE: STANDARD Product Information Features and Specifications For Use With: OEM Panels Approvals: UL

More information

1.3. Miniature Circuit Breakers and Supplementary Protectors. Contents. WMZS Circuit Breaker. UL 1077 DIN Rail Supplementary Protectors

1.3. Miniature Circuit Breakers and Supplementary Protectors. Contents. WMZS Circuit Breaker. UL 1077 DIN Rail Supplementary Protectors . Miniature Circuit Breakers and Supplementary Protectors UL 077 DIN Rail Supplementary Protectors WMZS Circuit Breakers Contents Description WMZS Circuit Breaker Standards and Certifications................

More information

MOTOR & CIRCUIT PROTECTION

MOTOR & CIRCUIT PROTECTION 2 MOTOR & CIRCUIT PROTECTION Motor Protection Circuit Breakers p2-1 Motor Protection Relays p2-13 Thermistor Protection Relay p2-18 Fuse Holders p2-20 Miniature Circuit Breakers p2-23 Residual Current

More information

NF44E-.. / NFZ44E-.. Contactor Relays AC / DC Operated - with Screw Terminals

NF44E-.. / NFZ44E-.. Contactor Relays AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC1010D0201 28/03/11 NFE-.. / NFZE-.. Contactor Relays AC / DC Operated - with Screw Terminals NF(Z) contactor relays are used for switching auxiliary and control circuits. NF(Z)

More information

Approved Standards. Motor Protection Circuit Breaker (MPCB) J7MN. MPCB system (motor protection CLASS 10) Auxiliary contact modules.

Approved Standards. Motor Protection Circuit Breaker (MPCB) J7MN. MPCB system (motor protection CLASS 10) Auxiliary contact modules. Motor Protection Circuit Breaker (MPCB) J7MN MPCB system (motor protection CLSS 0) Rotary and switch types Rated operational current = 2, 25, 50 and 00 Switching capacity up to 2.5 = 00 k/400 V Fixed short-circuit

More information

Description Basic devices with positive operation contacts. Standards IEC/EN 60947, EN , VDE 0660, UL, CSA

Description Basic devices with positive operation contacts. Standards IEC/EN 60947, EN , VDE 0660, UL, CSA Delivery program Contactor relay, 3N/O+1N/C, DC current Part no. DILA-31(24VDC) Catalog No. 276379 Eaton Catalog No. XTRE10B31TD EL-Nummer 4130206 (Norway) Product range DILA relays Application Contactor

More information

Disconnect Switches. Safe Switching and Disconnecting

Disconnect Switches. Safe Switching and Disconnecting IB105-UK_U1_U4_Pfade.indd 2-3 14.04.2005, 16:51:30 Disconnect Switches Safe Switching and Disconnecting Disconnect Switches from Salzer are hand-operated switchgear for main circuits and are offered as

More information

3RM1 Hybrid Starters 6SIRIUS. contents. Industrial Controls Product Catalog 2017

3RM1 Hybrid Starters 6SIRIUS. contents. Industrial Controls Product Catalog 2017 3RM1 Hybrid Starters Industrial Controls Product Catalog 2017 Section contents 3RM1 Compact - Hybrid Starters Overview /2 General Data /3 Selection and ordering data /4 Accessories /5 - /9 Technical Data

More information

CI-TI Contactors and Motor Starters Circuit Breakers CTI 25M, CTI 45MB, CTI 100

CI-TI Contactors and Motor Starters Circuit Breakers CTI 25M, CTI 45MB, CTI 100 MKING MODERN LIVING POSSIBLE Technical brochure CI-TI Contactors and Motor Starters Circuit Breakers CTI 25M, CTI 45MB, CTI 100 Circuit breakers for short circuit- and overload protection of motor applications

More information

MULTI 9 System Catalog UL Recognized C60N Supplementary Protectors

MULTI 9 System Catalog UL Recognized C60N Supplementary Protectors UL Recognized C60N Supplementary Protectors B Curve C60N Supplementary Protectors 1 MG24110 MG24125 MG24140 MG24155 15 MG17406 MG17436 MG17461 1.2 MG17402 MG17432 16 MG24118 MG24133 MG24148 MG24163 1.5

More information

IMS Control & EPR, We keep your motors running ABB s new control & protection devices up to 18.5 kw / 20 hp

IMS Control & EPR, We keep your motors running ABB s new control & protection devices up to 18.5 kw / 20 hp IMS Control & EPR, 2010 01 29 We keep your motors running ABB s new control & protection devices up to 18.5 kw / 20 hp October 27, 2010 1SBC101089D0201 ABB s new control and protection devices Up to 18.5

More information

low voltage GLOBAL CATALOGUE RANGE Motor Control Contactors - Thermal Overload Relay s - Manual Motor Starters

low voltage GLOBAL CATALOGUE RANGE Motor Control Contactors - Thermal Overload Relay s - Manual Motor Starters CTLOGUE GLOBL RNGE 2. Motor Control Contactors - Thermal Overload Relay s - Manual Motor Starters 2. 2. Product Overview. 2.2 Overload Relay Setting Range 2. - 2.8 Product Specifications 2.9-2. Contactor

More information

IEC Type Industrial Control Relays; TeSys D-Line, K-Line, and SK-Line K-Line Ordering Informaiton

IEC Type Industrial Control Relays; TeSys D-Line, K-Line, and SK-Line K-Line Ordering Informaiton K-Line Ordering Informaiton K-Line Ordering Information Control Relays - Mounting on 35 mm DIN3 track or 4 screw direct mounting. - Screws in open ready-to-tighten position. Control Circuit Contact Configuration

More information

UL 489 DIN Rail Miniature Circuit Breakers

UL 489 DIN Rail Miniature Circuit Breakers UL 489 DIN Rail Miniature Circuit Breakers Product Overview................................................ 2 Product Selection................................................ 4 Accessories.....................................................

More information

Allen-Bradley 700-K40E-DJ

Allen-Bradley 700-K40E-DJ Bulletin Overview/Product Selection Bulletin Miniature Control Relays IEC compact industrial relay IPX Finger Protection Bifurcated contacts for low-level signals Optional integrated coil protection diode

More information

TeSys contactors From 115 to 2750 A

TeSys contactors From 115 to 2750 A Selection guide From to 0 A Applications Control of all types of motor for standard or severe duty applications Control of resistive, inductive and capacitive circuits: heating, lighting, cos j rectification,

More information

UL 489 DIN Rail Miniature Circuit Breakers

UL 489 DIN Rail Miniature Circuit Breakers UL 9 DIN Rail Miniature Circuit Breakers Product Overview................................................ Product Selection................................................ Accessories.....................................................

More information

Motor Controllers AC Semiconductor Motor Controller Type RSHR MIDI

Motor Controllers AC Semiconductor Motor Controller Type RSHR MIDI otor Controllers AC Semiconductor otor Controller Type RSHR IDI Soft starting and stopping of 3-phase induction squirrel cage motors 2-phase control with integral bypassing of semiconductors Low inrush

More information

MAKING MODERN LIVING POSSIBLE. CI-TI Contactors and Motor Starters Circuit Breakers CTI 25M Technical brochure

MAKING MODERN LIVING POSSIBLE. CI-TI Contactors and Motor Starters Circuit Breakers CTI 25M Technical brochure MKING MODERN LIVING POSSIBLE CI-TI Contactors and Motor Starters Circuit Breakers CTI 25M - 100 Technical brochure 2 IC.PD.C00.5.02-520B3595 Danfoss /S (R-MC/mr) 08-2009 Contents Page Circuit Breakers/

More information

RM17UAS. Product datasheet Characteristics. voltage control relay RM17-U - range V DC. Main. Complementary. Price* : 70.

RM17UAS. Product datasheet Characteristics. voltage control relay RM17-U - range V DC. Main. Complementary. Price* : 70. Characteristics voltage control relay RM17-U - range 9..15 V DC Price* : 70.64 GBP Main Range of product Product or component type Relay type Product specific application Relay name Relay monitored parameters

More information

RM17UB3. Product data sheet Characteristics. voltage control relay RM17-U - range V AC. Main. Complementary

RM17UB3. Product data sheet Characteristics. voltage control relay RM17-U - range V AC. Main. Complementary Characteristics voltage control relay RM17-U - range 183..528 V AC Main Range of product Product or component type Relay type Product specific application Relay name Relay monitored parameters Time delay

More information

Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protectors Specifications Bulletin Number 1492, 1692

Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protectors Specifications Bulletin Number 1492, 1692 Technical Data Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protectors Specifications Bulletin Number 1492, 1692 Topic Page 1489-M Miniature Circuit Breakers 1 1492-SP Supplementary Protectors

More information

Motor-protective circuit-breaker, 3p, Ir=16-25A, screw connection. Product range PKZM4 motor protective circuit-breakers up to 65 A

Motor-protective circuit-breaker, 3p, Ir=16-25A, screw connection. Product range PKZM4 motor protective circuit-breakers up to 65 A DATASHEET - PKZM4-25 Delivery program Motor-protective circuit-breaker, 3p, Ir=16-25A, screw connection Part no. PKZM4-25 Catalog No. 222352 Eaton Catalog No. XTPR025DC1NL EL-Nummer 0004355158 (Norway)

More information

Rated operational Control Voltage Uc Supply Voltage Connection Rated operational current 40 C voltage Ue Us 25A AC-53a 32A AC-53a

Rated operational Control Voltage Uc Supply Voltage Connection Rated operational current 40 C voltage Ue Us 25A AC-53a 32A AC-53a otor Controllers AC Semiconductor otor Controller Type RSHR 3-Phase Soft starting and stopping of 3-phase squirrel cage motors Control of all 3 phases In Line or In Delta motor connection Low inrush and

More information

Ordering Key. Type Rated Operational Rated operational Control Voltage Uc Options

Ordering Key. Type Rated Operational Rated operational Control Voltage Uc Options otor Controllers AC Semiconductor otor Controller Type RSHR 3-Phase Soft starting and stopping of 3-phase squirrel cage motors Control of all 3 phases In Line or In Delta motor connection Low inrush and

More information

Section 4 Ground-Fault Protection Devices

Section 4 Ground-Fault Protection Devices Multi 9 System Catalog Section 4Ground-Fault Protection Devices Section 4Ground-Fault Protection Devices Selection Table The Multi 9 System includes one UL Listed and three IEC rated product families that

More information

MULTI 9 System Catalog UL Recognized NC100H Supplementary Protectors

MULTI 9 System Catalog UL Recognized NC100H Supplementary Protectors B Curve NC100H Supplementary Protectors Rating 1P 2P 3P 4P 80 MG27164 MG27175 MG27186 MG27197 MULTI 9 System Catalog UL Recognized NC100H Supplementary Protectors C Curve NC100H Supplementary Protectors

More information

Close Protection from Moeller. miniature branch circuit breakers miniature supplementary protectors

Close Protection from Moeller. miniature branch circuit breakers miniature supplementary protectors Close Protection from Moeller miniature branch circuit breakers miniature supplementary protectors FAZ branch circuit breakers General Information... Selection Tables Trip Characteristic C - Box terminals...

More information

RM35UB3. Product data sheet Characteristics. voltage control relay RM35-U - range V AC. Main. Complementary

RM35UB3. Product data sheet Characteristics. voltage control relay RM35-U - range V AC. Main. Complementary Characteristics voltage control relay RM35-U - range 194..528 V AC Main Range of product Product or component type Relay type Product specific application Relay name Relay monitored parameters Time delay

More information

Motor Controllers AC Semiconductor Motor Controller Type RSHR MIDI

Motor Controllers AC Semiconductor Motor Controller Type RSHR MIDI otor Controllers AC Semiconductor otor Controller Type RSHR IDI Soft starting and stopping of 3-phase induction squirrel cage motors 2-phase control with integral bypassing of semiconductors Low inrush

More information

Selection Guide. Control Circuit and Load Protection. Allen-Bradley 1489-M2C020

Selection Guide. Control Circuit and Load Protection. Allen-Bradley 1489-M2C020 Selection Guide Control Circuit and Load Protection Circuit Protection Portfolio 1489-M Circuit Breakers Approved for branch circuit protection in the United States and Canada, and certified as Miniature

More information

24973 Circuit Breaker MINIATURE CIRCUIT BREAKER, 440VAC, 10A, CIRCUIT BREAKER TYPE: STANDARD

24973 Circuit Breaker MINIATURE CIRCUIT BREAKER, 440VAC, 10A, CIRCUIT BREAKER TYPE: STANDARD United States 24973 Circuit Breaker MINIATURE CIRCUIT BREAKER, 440VAC, 10A, CIRCUIT BREAKER TYPE: STANDARD Image not available Product Information Features and Specifications Approvals: IEC 60947-2 Rated

More information

Electronic timer CT-ERS.21

Electronic timer CT-ERS.21 2CDC 251 057 F0t07 Features Rated control supply voltage 24 240 V AC/DC Single function ON delay timer One device includes 10 time ranges (0.05 s 300 h) 2 c/o contacts 2 LEDs for status indication Width

More information

CS7 Industrial Control Relays

CS7 Industrial Control Relays CS7 Industrial Control Relays Reliable, general purpose relays for heavy duty applications The base four pole CS7 relay can be expanded up to twelve poles with the addition of front and side mount auxiliaries

More information

1.2. Miniature Circuit Breakers and Supplementary Protectors. Contents. WMZ Circuit Breaker. UL 489 DIN Rail Miniature Circuit Breakers

1.2. Miniature Circuit Breakers and Supplementary Protectors. Contents. WMZ Circuit Breaker. UL 489 DIN Rail Miniature Circuit Breakers .2 WMZ Circuit Breakers Contents Description WMZ Circuit Breaker Standards and Certifications.............. Selection................ Product Selection....................... Accessories...........................

More information

Electronic timer CT-ARS.11

Electronic timer CT-ARS.11 2CDC 251 088 F0t07 Features Rated control supply voltage 24 240 V AC/DC Single function OFF delay timer without auxiliary voltage One device includes 7 time ranges (0.05 s 10 min) 1 c/o (SPDT) contact

More information

Allen-Bradley 1492-RCDA4A40

Allen-Bradley 1492-RCDA4A40 Dual terminals provide wiring/bus bar flexibility and clamp from both sides to improve connection reliability Suitable for DIN Rail mounting Approval marks are easily visible on dome Terminal design helps

More information

MOTOR PROTECTION CIRCUIT BREAKERS

MOTOR PROTECTION CIRCUIT BREAKERS MOTOR PROTECTION CIRCUIT BREAKERS PAGE -2 PAGE -2 SMA Thermal trip adjustment ranges 9-32A (5 choices) Breaking capacity Icu at 400V: 50kA Suitable for mounting in consumer switchboards with minimum 58mm

More information

60103 Circuit Breaker

60103 Circuit Breaker 6003 Circuit Breaker United States MINIATURE CIRCUIT BREAKER, 20/240VAC, 2A, CIRCUIT BREAKER TYPE: STANDARD Image not available Product Information Features and Specifications Circuit Breaker Type: Standard

More information

Miniature Circuit Breakers and Supplementary Protectors. Contents

Miniature Circuit Breakers and Supplementary Protectors. Contents . Optimum and Efficient Protection for Every Application Product Overview Features Optimum product quality, tested reliability and safety stand for best protection of personnel, installations and plant.

More information

RM35TF V AC

RM35TF V AC Characteristics multifunction phase control relay RM35-T - range 194..528 V AC Main Range of product Product or component type Relay type Product specific application Relay name Relay monitored parameters

More information

Motors Automation Energy Transmission & Distribution Coatings. DWB Molded Case Circuit Breakers DWB

Motors Automation Energy Transmission & Distribution Coatings. DWB Molded Case Circuit Breakers DWB Motors Automation Energy Transmission & Distribution Coatings DWB Molded Case Circuit Breakers DWB Molded Case Circuit Breakers Molded Case Circuit Breakers DWB Summary Presentation 0 General Characteristics

More information

UL 489 Cable-In / Cable-Out Branch Circuit Breaker

UL 489 Cable-In / Cable-Out Branch Circuit Breaker Product Overview UL 9 Cable-In / Cable-Out Branch Circuit Breaker PRODUCT OVERVIEW Optimum and Efficient Protection Features Complete range of UL 9 listed DIN rail mounted miniature circuit breakers up

More information

Selection Guide. Control Circuit and Load Protection

Selection Guide. Control Circuit and Load Protection Selection Guide Control Circuit and Load Protection Circuit Protection Portfolio 1489-M Circuit Breakers Approved for branch circuit protection in the United States and Canada, and certified as Miniature

More information

Technical data. Safety parameters: see page 333. DC maximum residual ripple: 10% Supply voltage tolerance: DC consumption: Control circuit

Technical data. Safety parameters: see page 333. DC maximum residual ripple: 10% Supply voltage tolerance: DC consumption: Control circuit Safety module CS DM-01 Technical data Housing PA 6.6 polyamide housing, self-extinguishing, V0 acc. to UL 94 Protection degree IP40 (housing), IP20 (terminal strip) Dimensions see page 283, design A Two-hand

More information

Bulletin 817 Thermistor Protection Relay

Bulletin 817 Thermistor Protection Relay 6 Bulletin 817 Accurate Temperature Monitoring for Critical Applications Automatic, Manual and Remote Reset Status Indicating LEDs DIN Rail or Panel Mounting Guarded Terminals IP20 1 N.O. and 1 N.C. Output

More information

Control Circuit and Load Protection Products

Control Circuit and Load Protection Products Selection Guide Control Circuit and Load Protection Products Bulletin Numbers 188, 1489, 1492, 1692 Circuit Protection Portfolio 1489-M Circuit Breakers Approved for branch circuit protection in the United

More information

Supplementary Circuit Protectors Type GSB63

Supplementary Circuit Protectors Type GSB63 Supplementary Circuit Protectors Type GSB63 l Protection of circuits against short circuit and overload currents l UL1077 supplementary protection l 1,, 3 and 4 pole arrangements l 13 amperage sizes up

More information

Product Guide. UL 1077 DIN Rail Supplementary Protectors

Product Guide. UL 1077 DIN Rail Supplementary Protectors Product Guide UL 0 DIN Rail Supplementary Protectors UL 0 DIN Rail Supplementary Protectors Product Overview... Product Selection WMZS B Curve ( X I n Current Rating)..............................................

More information

Allen-Bradley Bulletin 100 Contactors

Allen-Bradley Bulletin 100 Contactors Allen-Bradley Bulletin 100 Contactors An integrated portfolio of IEC Contactors that save panel-space and energy Features and Benefits: Direct-on-line and reversing contactors Built-in surge suppression

More information

Electronic timer CT-ERD.12

Electronic timer CT-ERD.12 2CDC 251 092 F0t06 a Rotary switch for the preselection of the time range b Potentiometer with direct reading scale for the fine adjustment of the time delay c U: green LED V control supply voltage applied

More information

Selection Guide. Control Circuit and Load Protection

Selection Guide. Control Circuit and Load Protection Selection Guide Control Circuit and Load Protection Circuit Protection Portfolio 1489-M Circuit Breakers Approved for branch circuit protection in the United States and Canada, and certified as Miniature

More information

VEO. V2PF480Y/277VSY01 Art.Nr.: V2PF480Y/277VSY01P Art.Nr.: TECHNICAL DATA

VEO. V2PF480Y/277VSY01 Art.Nr.: V2PF480Y/277VSY01P Art.Nr.: TECHNICAL DATA Monitoring of phase sequence and phase loss Monitoring of asymmetry Supply voltage 208-480 V AC Supply circuit = measuring circuit 1 change-over contact Width 22,5 mm Control elements Asymmetry Status

More information

1.1. Contactors and Starters... Contents Description Relays and Timers... Miniature Controls... Manual Motor Protectors. XT IEC Power Control

1.1. Contactors and Starters... Contents Description Relays and Timers... Miniature Controls... Manual Motor Protectors. XT IEC Power Control . Contents Description Relays and Timers......................... Miniature Controls......................... Contactors and Starters.................... Thermal Overload Relays.................... C440/XT

More information

K-Line Mini - Contactors, Overload Relays and Accessories

K-Line Mini - Contactors, Overload Relays and Accessories K-Line Mini - Contactors, Overload Relays and Accessories Class 8502 CONTENTS Description...................................................... Page General Information...............................................

More information

VEO. V2ZS V AC/DC Art.Nr.: V2ZS20P V AC/DC Art.Nr.: TECHNICAL DATA

VEO. V2ZS V AC/DC Art.Nr.: V2ZS20P V AC/DC Art.Nr.: TECHNICAL DATA 4 time ranges 4 transition times Supply voltage 12-240V AC/DC 2 normally open contacts Width 22,5 mm Control elements Fine adjustment star contactor Setting of time range star contactor Transit time Status

More information

Electronic timer CT-ERS.12 ON-delayed with 1 c/o contact Data sheet

Electronic timer CT-ERS.12 ON-delayed with 1 c/o contact Data sheet 2CDC 251 056 F0t07 Features Rated control supply voltage 24-48 V DC, 24-240 V AC Single-function ON-delay timer One device includes 10 time ranges (0.05 s - 300 h) 1 c/o contact 2 LEDs for status indication

More information

Complete UL/CSA Disconnect Switch Kits

Complete UL/CSA Disconnect Switch Kits Product Selection Complete UL/CSA Disconnect Switch Kits Includes disconnect switch, operating handle with defeater mechanism and operating shaft, NFPA handle, auxiliary contacts, and padlock attachment.

More information

BNS SERIES - COMPATIBLE SERIES AES SAFETY CONTROLLERS SELECTION CHART AVAILABLE STANDARD MODELS

BNS SERIES - COMPATIBLE SERIES AES SAFETY CONTROLLERS SELECTION CHART AVAILABLE STANDARD MODELS BNS SERIES - COMPATIBLE SERIES AES SAFETY CONTROLLERS SELECTION CHART AVAILABLE STANDARD MODELS Safety Controller Suitable for use with Coded-Magnet Sensor Part Numbers below BNS250... BNS33... BNS303...

More information

Electronic timer CT-AHD.22

Electronic timer CT-AHD.22 2CDC 251 093 F0t06 a Rotary switch for the preselection of the time range b Potentiometer with direct reading scale for the fine adjustment of the time delay c U: green LED V control supply voltage applied

More information

IDE Load break switches for machine control Remotely trippable switch from 32 to 160 A

IDE Load break switches for machine control Remotely trippable switch from 32 to 160 A The solution for Load break switches > Industry. > Non critical buildings. > Public Access Sites. > High Rise Buildings. ide_021_a_1_cat ide_022_a_1_cat IDE 4x40 A External operation IDE 4x40 A Direct

More information

Contact protection relay

Contact protection relay Contact protection relay Ordering details SVR 450 08 F0000 The protects sensitive control contacts from excessive load. It can be used with latching function or without. Bounce time of control contacts

More information

Jtec 10kA Miniature Circuit Breaker

Jtec 10kA Miniature Circuit Breaker Jtec 0kA Miniature Circuit Breaker EN 60898 The Jtec range has been enthusiastically adopted by a diverse range of customers seeking a cost effective 0kA performance. Jtec MCBs are available in a wide

More information

Safety relay emergency stop/protective door, 24VDC/AC, 4 enabling paths

Safety relay emergency stop/protective door, 24VDC/AC, 4 enabling paths DATASHEET - ESR5-NO-41-24VAC-DC Safety relay emergency stop/protective door, 24VDC/AC, 4 enabling paths Part no. ESR5-NO-41-24VAC-DC Catalog No. 118701 EL-Nummer (Norway) 0004133317 Delivery program Product

More information

Application Switchgear for industrial and advanced commercial applications. U e V AC 240/ (per pole) I cs 7,5 ka

Application Switchgear for industrial and advanced commercial applications. U e V AC 240/ (per pole) I cs 7,5 ka DATASHEET - FAZ-C16/1 Miniature circuit breaker (MCB), 16A, 1p, C-Char, AC Part no. FAZ-C16/1 Catalog No. 278561 Eaton Catalog No. FAZ-C16/1 EL-Nummer 0001695154 (Norway) Similar to illustration Delivery

More information

Miniature Circuit Breakers for Railway Applications

Miniature Circuit Breakers for Railway Applications Siemens AG 00 for Railway Applications BETA Low-Voltage Circuit Protection The miniature circuit breakers are used in fixed railway systems and rolling stock for protecting system components against overcurrent

More information

Overloads. RW Series Catalog Number Sequence. RW Series - Bi-Metallic Thermal Overload Relays. Standard Features 3 - RW 27-1D

Overloads. RW Series Catalog Number Sequence. RW Series - Bi-Metallic Thermal Overload Relays. Standard Features 3 - RW 27-1D Circuit Protection Disconnect Switches Thermal Overload Relays n extended operational service life is one of the main features you can find in RW overload relays. WEG s RW Thermal Overload Relays are designed

More information

Load Feeders and Motor Starters for Use in the Control Cabinet

Load Feeders and Motor Starters for Use in the Control Cabinet Load Feeders and Motor Starters for Use in the Control Cabinet Price groups 12W, 14O, 230, 241, 250, 260, 41B, 41D, 41E, 41L, 42C, 42D, 42F, 471, 4N1, 5K1, 5K2, 5N2, 764, 15, 16 /2 Introduction SIRIUS

More information

FUSERBLOC UL Fusible disconnect switches UL and CSA from 30 to 800 A

FUSERBLOC UL Fusible disconnect switches UL and CSA from 30 to 800 A Fuse protection The solution for > Motor on-load disconnect > Protection of industrial cabinet > Electrical distribution ul_004_a Strong points fuser-ul_006_a Function FUSERBLOC UL fusible disconnect switches

More information

78 Series Electromechanical Relay Selection Guide

78 Series Electromechanical Relay Selection Guide 78 Series Electromechanical Relay Selection Guide Specification 781 Series 782 Series 783 Series 784 Series Coil Voltages Configuration SPDT DPDT 3PDT 4PDT Contact Rating 15A 15A 15A 15A Base Socket 5

More information

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous Safety relay for monitoring E-STOP pushbuttons. Approvals Unit features Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous 1 auxiliary contact (N/C), instantaneous Safe separation of

More information

IEC Power Control Overload Relays

IEC Power Control Overload Relays IEC Power Control Overload Relays Contents Contents Thermal overload relays Solid state overload relays 3RU21 overload relays up to 100 A with screw connection, CLASS 10 Page Selection and ordering data

More information

Motor protection circuit breakers

Motor protection circuit breakers R Motor protection circuit breakers Motor protection circuit breakers are used for start-up and protection of electric motors (industry, small machines, external use, agricultural machines, compressors,

More information

Application Switchgear for industrial and advanced commercial applications. U e V AC 277/480 Y V DC 60

Application Switchgear for industrial and advanced commercial applications. U e V AC 277/480 Y V DC 60 DATASHEET - FAZ-C5/2-RT Miniature circuit breaker (MCB), 5A, 2p, C-Char, AC Part no. FAZ-C5/2-RT Catalog No. 102203 Eaton Catalog No. FAZ-C5/2-RT EL-Nummer 1691799 (Norway) Similar to illustration Delivery

More information

RM22TG. Product data sheet Characteristics. three-phase control relay Vac, 2 C/O. Main. Complementary. Network number of phases

RM22TG. Product data sheet Characteristics. three-phase control relay Vac, 2 C/O. Main. Complementary. Network number of phases Characteristics three-phase control relay 183 528Vac, 2 C/O Main Range of product Product or component type Relay type Network number of phases Relay name Relay monitored parameters Time delay type Switching

More information

Electronic timer CT-SDD.22 Star-delta change-over with 2 n/o contacts

Electronic timer CT-SDD.22 Star-delta change-over with 2 n/o contacts Data sheet Electronic timer CT-SDD. Star-delta change-over with n/o contacts The CT-SDD. is an electronic time relay with star-delta change-over. It is from the CT-D range. With their MDRC profile and

More information

Switching relay CT-IRS with 1, 2 or 3 c/o contacts Data sheet

Switching relay CT-IRS with 1, 2 or 3 c/o contacts Data sheet 1SVR 430 221 F7300 2 1 3 Characteristics Switching relay ON-delay approx. 10 ms 1, 2 or 3 c/o contacts Switching relay with gold-plated contacts Width 22.5 mm Approvals e f GOST CCC CT-IRS 1 U/R: green

More information

VEO. V2UF230V10 Art.Nr.: TECHNICAL DATA

VEO. V2UF230V10 Art.Nr.: TECHNICAL DATA Continous voltage monitoring Mains fluctuation detection Detects voltage drop / short interruptions of at least 10ms Prevents undefined states in switching and control systems Generates reset pulse after

More information

CS7 Industrial Control Relays

CS7 Industrial Control Relays CS7 Industrial Control Relays Reliable, general purpose relays for heavy duty applications The base four pole CS7 relay can be expanded up to twelve poles with the addition of front and side mount auxiliaries

More information

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors Safety relay for monitoring E-STOP pushbuttons, safety gates and light barriers. Approvals Block diagram Unit features Positive-guided relay outputs: 6 safety contacts (N/O), instantaneous 4 auxiliary

More information