DSTHM-2 COMBINED T AND RH DUCT TRANSMITTER. Mounting and operating instructions
|
|
- Merry McDaniel
- 5 years ago
- Views:
Transcription
1 Mounting and operating instructions
2 Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE 4 TECHNICAL DATA 4 STANDARDS 4 OPERATIONAL DIAGRAMS 5 WIRING AND CONNECTIONS 5 MOUNTING & OPERATING INSTRUCTIONS IN STEPS 5 OPERATING INSTRUCTIONS 8 VERIFICATION OF INSTALLATION INSTRUCTIONS 9 MODBUS REGISTER MAPS 9 TRANSPORT AND STOCK KEEPING INFORMATION 10 WARRANTY AND RESTRICTIONS 10 MAINTENANCE 10 MIW--EN / 05 /
3 SAFETY AND PRECAUTIONS Read all the information, the datasheet, mounting and operating instructions and study the wiring and connection diagram before working with the product. For personal and equipment safety, and for optimum product performance, make sure you entirely understand the contents before installing, using, or maintaining this product. For safety and licensing (CE) reasons, unauthorised conversion and / or modifications of the product are inadmissible. The product should not be exposed to abnormal conditions, such as: extreme temperatures, direct sunlight or vibrations. Long-term exposure to chemical vapours in high concentration can affect the product performance. Make sure the work environment is as dry as possible; avoid condensation. All installations shall comply with local health and safety regulations and local electrical standards and approved codes. This product can only be installed by an engineer or a technician who has expert knowledge of the product and safety precautions. Avoid contacts with energised electrical parts; always treat the product as if it is live. Always disconnect the power supply before connecting, servicing or repairing the product. Always verify that you apply appropriate power supply to the product and use appropriate wire size and characteristics. Make sure that all the screws and nuts are well tightened and fuses (if any) are fitted well. Recycling of equipment and packaging should be taken into consideration and these should be disposed of in accordance with local and national legislation / regulations. In case there are any questions that are not answered, please contact your technical support or consult a professional. MIW--EN / 05 /
4 PRODUCT DESCRIPTION The series are combined duct transmitters which measure temperature and relative humidity. They are Power over Modbus supplied and all parameters are accessible via Modbus RTU. ARTICLE CODES Code Supply Connection Power over Modbus, 24 VDC RJ45 INTENDED AREA OF USE Monitoring duct temperature and relative humidity in HVAC applications TECHNICAL DATA Selectable temperature and relative humidity ranges Selectable temperature range: 0 50 C Selectable relative humidity range: 5 85 % Accuracy: ±0,4 C (0 50 C); ±3 % rh (5 85 % rh), depending on the selected parameter Option for uploading a new firmware via Modbus RTU Minimum airflow velocity required: 1 m/s Enclosure and probe material: ASA, grey (RAL9002) Protection standard: Enclosure: IP54, Probe: IP20 Operating ambient conditions: temperature: 0 50 C rel. humidity: 5 85 % rh, (non-condensing) Storage temperature: C STANDARDS EMC Directive 2014/30/EC: EN :2013 Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 1: General requirements EN :2013 Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-3: Particular requirements - Test configuration, operational conditions and performance criteria for transducers with integrated or remote signal conditioning WEEE Directive 2012/19/EC RoHs Directive 2011/65/EC MIW--EN / 05 /
5 OPERATIONAL DIAGRAMS Input register 1 [%] 100 Input register 2 [%] Min. range Max. range 50 T [ C] 0 5 Min. range Max. range 85 rh [%] WIRING AND CONNECTIONS Pins 1 & 2 Pins 3 & 4 Pins 5 & 6 Pins 7 & 8 24 VDC A /B GND Supply voltage (24 VDC) RS485, Modbus RTU communication, signal A RS485, Modbus RTU communication, signal /B Supply voltage, ground 24 VDC 8 mm A /B GND 8 mm 8 mm 8 mm RJ MOUNTING & OPERATING INSTRUCTIONS IN STEPS Before you start mounting the duct transmitter, read carefully Safety and Precautions. 1. When preparing to mount the, bear in mind that the unit itself must be installed onto the outer surface of the duct both via fixing the flexible flange or directly the unit enclosure, while the probe must be inserted inside the duct, see Fig. 1 and Fig. 2 below. MIW--EN / 05 /
6 Fig. 1 Mounting dimensions With flange Without flange 50 Ø 12 2x Ø , ,3 86, x Ø 4, ,5 Fig. 2 Mounting position Correct Incorrect AIR FLOW AIR FLOW 2. Having selected the appropriate mounting location, proceed with the following steps: 2.1 Drill a Ø 13 mm hole into the duct and insert the probe. Apply an air-tight sealing between probe and duct. 2.2 Fix the flange onto the duct outer surface using the self-drilling screws delivered with the unit. If you do not intend to use the flange, insert the tube and fix the enclosure onto the duct. Mind the airflow direction (see Fig. 2 and Fig. 3). MIW--EN / 05 /
7 Fig. 3 Mounting requirements 7,5*D (1) 3,5*D (1) D = Duct diameter ATTENTION Installation requirements: The must not be installed in turbulent air zones. Ensure sufficiently long settling zones upstream and downstream of the tapping point. A settling zone consists of a straight section of pipe or duct with no obstructions. Avoid installation near filters, cooling coils, fans, etc. The sensor will achieve the optimal result when the measurement is taken at least 7,5 duct diameters downstream and at least 3 duct diameters upstream from any turns or flow obstructions. ATTENTION Installation of the unit near high EMI-emitting devices may lead to faulty measurements. Use shielded wiring in areas with high EMI. ATTENTION Keep at least 15 cm distance between the sensor lines and the 230 VAC power lines. 2.3 Install the tube at the desired depth and, in case you use the flange, fix it via the plastic white screw in the flexible flange. 2.4 Unscrew the cover of the unit to remove it and insert the connecting cable through the cable gland of the unit. 2.5 Crimp the RJ45 cable and plug it into the socket, see Fig. 4 and section Wiring and connections above. Fig. 4 Wiring and connections 3. Customise the factory settings to the desired ones via the 3SModbus software or Sensistant (if necessary). For the default factory setting see Table Modbus register maps. MIW--EN / 05 /
8 Optional settings If your unit is the first or the last unit on the Modbus RTU network (see Example 1 and Example 2), enable the NBT resistor via 3SModbus or Sensistant (Holding Register 30). If your device is not an end device, leave the NBT disabled (default Modbus setting). Example 1 Example 2 Slave 1 NBT NBT RX ТX Master NBT RX ТX NBT Slave 2 Master NBT Slave n Slave 1 Slave 2 Slave n 4. Close the enclosure and fix the cover. 5. Switch on the power supply. CAUTION Do not expose to direct sunlight! OPERATING INSTRUCTIONS Calibration procedure: Both the relative humidity and temperature sensor elements are factory calibrated. Recalibration is not necessary. Bootloader Thanks to the bootloader functionality, the sensor firmware can be updated via Modbus RTU communication. To enter Boot mode, put a jumper onto pins 3 and 4 of the P1 header and restart the power supply (see Fig. 5). Once Boot mode is activated, the firmware can be updated via SM Boot application (part of 3SModbus software suite) or Sensistant. Fig. 5 P1 header Put a jumper onto pins 1 and 2 and wait for at least 5 seconds to reset the Modbus communication parameters Put a jumper onto pins 3 and 4 and restart the supply to enter bootloader mode MIW--EN / 05 /
9 VERIFICATION OF INSTALLATION INSTRUCTIONS If your unit does not function as expected, please check the connections. MODBUS REGISTER MAPS INPUT REGISTERS Data type Description Data Values 1 Temperature signed int. Actual temperature level ,0 C 2 Relative humidity Actual relative humidity level ,0 % rh 3 Dew point signed int. Calculated dew point ,0 C 4 10 Reserved, return 0 11 Output value 1 (T) Output value - temperature Output value 1 (rh) Output value - relative humidity Reserved, returns 0 14 Temperature alert flag 15 Relative humidity alert flag 16 Reserved, returns Temperature range limit flag Relative humidity range limit flag 19 Reserved, returns 0 20 Humidity / temperature sensor fault HOLDING REGISTERS Flag indicates that measured temperature is outside set alert values. Set to 1 when the measured value is outside the temperature alert values defined by holding registers 20 and 21. Flag indicates that measured relative humidity is outside set alert values. Set to 1 when the measured value is outside the relative humidity alert values defined by holding registers 22 and 23 Flag indicates that measured temperature is outside set range limit values. Set to 1 when the measured value is outside the temperature range limit values defined by holding registers 14 and 15 Flag indicates that measured relative humidity is outside set range limit values. Set to 1 when the measured value is outside the relative humidity limit range values defined by holding registers 16 and 17 Flag indicates if the communication with the temperature and humidity sensor is lost Data type Description Data Default Values 1 Device slave address Modbus device address Modbus baud rate Modbus communication baud rate Modbus parity mode Parity check mode Device type Device type (Read only) = % 100 % 0 % 100 % Measured temperature is OK Measured temperature is too high/ low Measured rh is OK Measured rh is too high/ low Temperature range is OK Temperature range is too high/ low rh range is OK rh range is too high/ low 5 HW version Hardware version of the device (Read only) XXXX 0x010 HW version FW version Firmware version of the device (Read only) XXXX 0x010 FW version Reserved, return Minimum temperature range Maximum temperature range Minimum relative humidity range Maximum relative humidity range Reserved, return Minimum temperature alert Maximum temperature alert Minimum relative humidity alert Maximum relative humidity alert Minimum value of the temperature range; cannot be set higher than max. temperature range minus 5ºC Maximum value of temperature range; cannot be set lower than min. temperature rang e plus 5ºC Minimum value of the rh range; cannot be set higher than max. rh range minus 5% Maximum value of rh range; cannot be set lower than min. rh range plus 5% Minimum temperature alarm value Maximum temperature alarm value Minimum relative humidity alarm value Maximum relative humidity alarm value Reserved, return 0 30 Modbus network resistor termination (NBT) 2 = 3 = 4 = 5 = 6 = 2 = No Yes N1 8E1 8O1 0 (Max. range - 50) ,0 C (Min. range + 50) ,0 C 50 (Max. range 50) ,0 % rh (Min. range + 50) = 85,0 % rh Min. temperature range Max. temperature alarm Min. temperature alarm Max. temperature range Min. relative humidity range Max. relative humidity alarm Min. relative humidity alarm Max. relative humidity range Set device as ending the line or not by connecting NBT Reserved, returns Modbus registers reset Reserved, return 0. Resets Modbus Holding registers to default values. When finished this register is automatically reset to 0 If you want to find out more about Modbus over serial line, please visit: ,0 ºC ,0 ºC ,0 % rh ,0 % rh NBT disconnected NBT connected Idle Reset Modbus registers MIW--EN / 05 /
10 TRANSPORT AND STOCK KEEPING INFORMATION Avoid shocks and extreme conditions; store in original packing. WARRANTY AND RESTRICTIONS Two years from the delivery date against defects in manufacturing. Any modifications or alterations to the product after the date of publication relieve the manufacturer of any responsibilities. The manufacturer bears no responsibility for any misprints or mistakes in this data. MAINTENANCE In normal conditions this product is maintenance-free. If soiled, clean with a dry or damp cloth. In case of heavy pollution, clean with a non aggressive product. In these circumstances the unit should be disconnected from the supply. Pay attention that no fluids enter the unit. Only reconnect it to the supply when it is completely dry. MIW--EN / 05 /
DXTH DUCT SENSOR / SWITCH FOR TEMPERATURE AND HUMIDITY. Mounting and operating instructions
DUAL DUCT SENSOR / SWITCH FOR TEMPERATURE AND HUMIDITY Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE 4 TECHNICAL
More informationHPS-M -2 DIFFERENTIAL PRESSURE TRANSMITTER. Mounting and operating instructions
DIFFERENTIAL PRESSURE Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE 4 TECHNICAL DATA 4 STANDARDS 5 OPERATIONAL
More informationRST ROOM TEMPERATURE TRANSMITTER. Mounting and operating instructions
Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE 4 TECHNICAL DATA 4 STANDARDS 4 OPERATIONAL DIAGRAM 5 WIRING AND
More informationRXTH DUAL ROOM SENSOR / SWITCH
DUAL ROOM SENSOR / SWITCH FOR TEMPERATURE AND RELATIVE HUMIDITY Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE
More informationRXTP ROOM TEMPERATURE
ROOM TEMPERATURE CONTROLLER WITH PI CONTROL Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE 4 TECHNICAL DATA 4
More informationCNVT-USB-RS485 MODBUS TO USB CONVERTER. Operating instructions
USB CONVERTER Operating instructions Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 INTENDED AREA OF USE 4 TECHNICAL DATA 4 STANDARDS 4 WIRING AND CONNECTIONS 5 OPERATING INSTRUCTIONS
More informationMVS RAIL ELECTRONIC FAN SPEED CONTROLLER. Mounting and operating instructions
DIN RAIL ELECTRONIC FAN SPEED Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE 4 TECHNICAL DATA 4 STANDARDS 5 WIRING
More informationRTT2 ROOM TEMPERATURE SWITCH. Mounting and operating instructions
Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS PRODUCT DESCRIPTION ARTICLE CODES INTENDED AREA OF USE TECHNICAL DATA STANDARDS OPERATIONAL DIAGRAMS WIRING AND CONNECTIONS
More informationRТTH DUAL ROOM SWITCH
DUAL ROOM SWITCH FOR TEMPERATURE AND RELATIVE HUMIDITY Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS PRODUCT DESCRIPTION ARTICLE CODES INTENDED AREA OF USE TECHNICAL DATA
More informationSTR-3 STANDARD 3-PHASE 230 VAC TRANSFORMER CONTROLLER. Mounting and operating instructions
STANDARD 3-PHASE 230 VAC TRANSFORMER CONTROLLER Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE 4 TECHNICAL DATA
More informationDPOM8-24/20 DIN RAIL POWER OVER MODBUS MODULE. Mounting and operating instructions
Mounting and operating instructions Table of contents SFETY ND PRECUTIONS 3 PRODUCT DESCRIPTION 4 RTICLE CODES 4 INTENDED RE OF USE 4 TECHNICL DT 4 STNDRDS 4 WIRING ND CONNECTIONS 5 MOUNTING INSTRUCTIONS
More informationDWYER INSTRUMENTS, INC. Series AVUL Air Velocity Transmitter. Specifications - Installation and Operating Instructions.
Series AVUL Air Velocity Transmitter Specifications - Installation and Operating Instructions Bulletin P-AVUL 3-49/64 [95.71] 2-43/64 [67.92] 1/2 NPS 3-3/16 [80.81] 1-19/32 [40.59] 31/32 24.58 3-33/64
More informationInstruction Manual. T3110 T3110L T3110Ex
www.cometsystem.cz Instruction Manual T3110 T3110L T3110Ex Programmable transmitter of temperature, relative humidity and other calculated humidity values with 4-20 ma outputs Copyright: COMET System,
More informationDuct humidity and temperature sensor for all HVAC duct applications. Designed for control and monitoring applications.
FTK RS485 Modbus Duct sensor for relative humidity and temperature Data Sheet Subject to technical alteration Issue date: 18052015 Application Duct humidity and temperature sensor for all HVAC duct applications
More informationApplication. Types Available. Duct sensor for air quality, temperature and humidity (optional) Datasheet
LK+ CO2+VOC Duct sensor for air quality, temperature and humidity (optional) Datasheet Subject to technical alteration Issue date: 04.04.2018 A002 Application Duct air quality sensor for detection of CO2,
More informationOutput Signal. 22DTM-16 BACnet DC V, DC V. Electrical data Power Supply DC V, ±10%, 0.3 W
Duct Sensor CO₂ / Humidity / Temperature Duct air quality sensor for combined detection of CO₂, relative humidity and temperature. Designed for control and monitoring applications. Type Overview Type Output
More informationOutput Signal Active Note DC V. Electrical Data Power Supply DC V, ±10%, 1.4 W
Differential Pressure Sensor (Air) Differential pressure transmitter with 8 selectable ranges 0 to 5/10 V, 4 to 20 ma outputs and Modbus functionality. NEMA 4X / IP65 rated enclosure. For monitoring the
More informationGREISINGER electronic GmbH D Regenstauf, Hans-Sachs-Straße 26
H20.0.24.6C1-07 EASYBus-Sensor module for humidity temperature with option: selectable humidity display from version V3.2 Operating Manual EBHT 2R / UNI Content 1 INTENDED USE 2 2 GENERAL ADVICE 2 3 SAFETY
More informationCarbon Monoxide Sensor - ModBus
Introduction The CO Sensor uses an electrochemical sensor to monitor CO level in a range of 0 to 500 ppm and communicates via an RS-485 network configured for ModBus protocol. Before Installation Read
More informationDIFFERENTIAL PRESSURE TRANSMITTER with MODBUS interface Optional Input module
DIFFERENTIAL RESSURE TRANSMITTER with MODBUS interface Optional Input module DT-MOD (-IN) Summary Each device is individually temperature compensated. Type name (-IN for Input module) (-AZ for autozero)
More informationRHT-WM-485-LCD Transmitter and RHT-DM-485-LCD Transmitter
RHT-WM-485-LCD Transmitter and RHT-DM-485-LCD Transmitter TEMPERATURE AND HUMIDITY TRANSMITTER INSTRUCTIONS MANUAL V1.0x A 1 INTRODUCTION The RHT-WM-485-LCD and RHT-DM-485-LCD transmitters include high
More informationOutput Signal. Temperature 22DTH-56M BACnet DC V, DC V. Electrical Data Power Supply DC V, ±10%, 0.7 W
Duct Sensor Humidity / Temperature For measuring the relative or absolute humidity and temperature in duct applications. The measured values and absolute humidity, dewpoint and enthalpy are transmitted
More informationTRANSDUCER T4311, T4411
TRANSDUCER T4311, T4411 Programmable temperature transducer for RTD Pt1000 sensor with serial output RS232 and RS485 Instruction manual Instruction Manual for use of transducer: T4311 (RS232), T4411 (RS485)
More informationRoom unit with PPS2 interface
1 626 Room unit with PPS2 interface for use with: controllers with a PPS2 interface QAA88.3 Room temperature measurement Key buttons for adjustment of the room temperature setpoint Key buttons for operating
More informationOutput signal. 22DTM-16 BACnet DC V, DC V. Electrical data Power supply DC V, ±10%, 0.3 W
Duct Sensor CO₂ / Humidity / Temperature For combined measurement of CO₂, relative humidity and temperature in the duct. Dual channel CO₂ technology. The measured values are output via BACnet. NEMA 4X
More informationCDD4 Duct Carbon Dioxide Transmitter
Drill or punch a 1-1/8 or 1-1/4 hole in the duct at the preferred location and insert the probe into the hole to mark the enclosure mounting holes. Remove the unit and drill the four mounting holes. Clean
More informationPlease Read Instruction Carefully Before Installation! Figure 1: A/CO2-DUCT
Installation and Operation Instructions A/CO2-DUCT Series Please Read Instruction Carefully Before Installation! Figure 1: A/CO2-DUCT PRECAUTIONS REMOVE POWER BEFORE WIRING. NEVER CONNECT OR DISCONNECT
More informationMU110-6U. Analog output module 6 channel. User guide
MU110-6U Analog output module 6 channel User guide MU110-6U_2016.12_0221_EN All rights reserved Subject to technical changes and misprints akytec GmbH Vahrenwalder Str. 269 A 30179 Hannover Тел.: +49 (0)
More informationLED PANEL. User Manual Please read the instructions carefully before use LED-7TC. Innovation, Quality, Performance 15-
LED PANEL LED-7TC Innovation, Quality, Performance User Manual Please read the instructions carefully before use 15- 9. Fixture Cleaning TABLE OF CONTENTS 1. Safety Instructions 2. Technical Specifications
More informationPage 1 MRK-D-0011, V2.0 Aeroqual SM50 User Guide
Page 1 Table of Contents User Guide Revision History... 3 Description... 4 1. Operating Instructions... 4 1.1. Power... 4 1.2. Warm Up... 4 1.3. Standard Inputs and Outputs... 4 1.4. Using the Relay Output...
More informationData sheet GCM MOD GMM EC.1 Communications module Modbus for GMM EC
Data sheet GCM MOD GMM EC.1 Communications module Modbus for GMM EC ERP no.: 5206415 GCM MOD GMM EC.1 www.guentner.de Page 2 / 15 Contents 1 GCM MOD GMM EC.1...3 1.1 Functional description...3 1.2 Connections...
More informationDuct Sensors. Building Technologies HVAC Products. Symaro. for relative humidity and temperature with calibration certificates
1 883 1883P01 1883P02 QFM4160 AQF4150 Symaro Duct Sensors for relative humidity and temperature with calibration certificates QFM41 Operating voltage AC 24 V / DC 1353 Signal output DC 010 V / 420 ma for
More informationTransmitters RHT-WM-485-LCD, RHT-DM-485-LCD and RHT-P LCD
Transmitters RHT-WM-485-LCD, RHT-DM-485-LCD and RHT-P10-485-LCD TEMPERATURE AND HUMIDITY TRANSMITTER INSTRUCTIONS MANUAL V1.0x D 1 INTRODUCTION The RHT-WM-485-LCD, RHT-DM-485-LCD and RHT-P10-485-LCD transmitters
More informationGREISINGER electronic GmbH D Regenstauf, Hans-Sachs-Straße 26
H20.0.34.6C-05 EASYBus-Sensor module for temperature from version V3.2 Operating Manual EBT 2R Content 1 INTENDED USE 2 2 GENERAL ADVICE 2 3 SAFETY INSTRUCTIONS 2 4 DISPOSAL NOTES 2 5 ASSIGNMENT 3 6 DIMENSION
More informationDPA+ LCD. Application. Types Available. Differential Pressure Transmitter. Datasheet
DPA+ LCD Differential Pressure Transmitter 703420 Datasheet Subject to technical alteration Issue date: 07.03.2018 A002 Application Differential pressure and volume flow transducer for monitoring differential
More informationPage 1 MRK-D-0011, V1.1 Aeroqual SM50 User Guide
Page 1 Table of Contents 1. Description... 3 2. Operating Instructions... 3 2.1. Power... 3 2.2. Warm Up... 3 2.3. Input and Output signals... 3 2.3.1. ZERO CAL... 4 2.3.2. RESET... 4 2.3.3. SPAN... 4
More informationInBin-P Pressure switches from 5 Pa Pa
InBin-P Pressure switches from 5 Pa...100 Pa Electrical, binary pressure or differential pressure switches with adjustable switch activation delay 24 VAC/DC supply voltage, potential free switching contact
More informationON/OFF HUMIDIFIER CONTROL (ROOM 0R DUCT SENSOR) WITH OUTDOOR TEMPERATURE RESET OVERVIEW WALL CONTROLLER INSTALLATION (TCY-BH-T-U)
(ROOM 0R DUCT SENSOR) WITH OUTDOOR TEMPERATURE RESET TCY-BH-T-U Wall controller with sensor TDC-BH-T-U Duct controller with sensor SOA-Tn10 Outdoor temperature sensor (Optional) OVERVIEW For wall applications
More informationTEMPERATURE AND HUMIDITY TRANSDUCER P18 TYPE USER S MANUAL
TEMPERATURE AND HUMIDITY TRANSDUCER P18 TYPE USER S MANUAL 1 2 CONTENTS 1. APPLICATION... 5 2. BASIC REQUIREMENTS, OPERATIONAL SAFETY... 5 3. INSTALLATION... 5 3.1. Assembly...5 3.2. Electrical Connections...7
More informationasense m III in industrial wall mounted housing / CO sensor with built-in general purpose controller
Manual for Installation CO 2 asense m III in industrial wall mounted housing / CO sensor with built-in general purpose controller 9 10 2 1 6 10 8 3 4 5 7 Fig. 1 1 Wall plate 2 PCB (Factory supplied mounted
More informationUSER GUIDE PEL 8K / PEL 8K-M
V2.0.0 (24.10.2014) 1 (7) COMMISSIONING Mounting - The transmitter should be installed above the measuring point to avoid condensation problems. - The duct overpressure is detected by connecting the measuring
More informationB63/ NS MS. EtherNet/IP LINK
3 609 929 B63/ IMenip 2008-09 NS MS EtherNet/IP LINK 3 609 929 B63/2008-09 IMenip Bosch Rexroth AG 15/76 Table of Contents About this document................. 16 General safety instructions............
More informationenglish S-5EC Potentiometer 5-step Operating Instructions Keep for reference! L-BAL-E265-GB 1608 Index 002
S-5EC english Potentiometer 5-step Operating Instructions Keep for reference! Content 1 General notes............................................ 3 1.1 Structure of the operating instructions....................
More informationUSER GUIDE PEL / PEL-M
V2.0.0 (05.09.2014) 1 (6) COMMISSIONING Mounting - The transmitter should be installed above the measuring point to avoid condensation problems. - The duct overpressure is detected by connecting the measuring
More informationLED PANEL. User Manual Please read the instructions carefully before use LED-212RGB TABLE OF CONTENTS. 1. Safety Instructions
TABLE OF CONTENTS LED PANEL 1. Safety Instructions 2. Technical Specifications 3. Installation 4. How to set the unit 5. How to control the fixture 6. DMX512 Configuration 7. DMX512 Connections 8. Troubleshooting
More informationExpansion module EM-BAC-MOD-01. Installation manual
Installation manual GB/en Expansion module EM-BAC-MOD-01 BACnet MS/TP or Modbus RTU interface card for EASYLAB controller TCU3 and adapter module TAM Firmware from 4.0 TROX GmbH Heinrich-Trox-Platz 47504
More informationOZONE SWITCH Model OS-6. OS-6 Features
USER MANUAL OZONE SWITCH Model OS-6 OS-6 Features The OS-6 is an industrial grade ozone controller and monitor. The OS-6 design is optimized for accuracy and ease of installation, setup and operation.
More informationSee instructions to download and install the latest version of LinkBoxMB and the user's manual at
Safety Instructions WARNING Follow carefully this safety and installation instructions. Improper work may lead to serious harmful for your health and also may damage seriously the IntesisBox and/or any
More informationProgrammable temperature transducer from Pt1000 sensor to current loop 4-20 ma Instruction Manual
T4111 TRANSDUCER Programmable temperature transducer from Pt1000 sensor to current loop 4-20 ma Instruction Manual Instruction manual for use of T4111 transducer Transducer is designed for temperature
More informationSee instructions to download and install the latest version of LinkBoxMB and the user's manual at
Safety Instructions WARNING Follow carefully this safety and installation instructions. Improper work may lead to serious harmful for your health and also may damage seriously the IntesisBox and/or any
More informationEE160 - Humidity and Temperature Transmitter for HVAC Applications
USER S GUIDE EE160 - Humidity and Temperature Transmitter for HVAC Applications GENERAL The EE160 transmitter, available for wall or duct mounting, is designed for the measurement of humidity and temperature
More informationSee instructions to download and install the latest version of LinkBoxMB and the user's manual at
Safety Instructions WARNING Follow carefully this safety and installation instructions. Improper work may lead to serious harmful for your health and also may damage seriously the IntesisBox and/or any
More informationEE671 - Miniature Air Flow Transmitter
USER s guide EE671 - Miniature Air Flow Transmitter GENERAL The EE671 air velocity transmitter operates on the hot-film anemometer principle and features an innovative, very robust E+E sensing element
More informationRoom sensors QFA4160 QFA41 D AQF4150 AQF3153. Symaro. for relative humidity and temperature with calibration certificates
1 859 1859P01 1859P02 1859P04 QFA4160 QFA41 D AQF4150 AQF3153 Symaro Room sensors for relative humidity and temperature with calibration certificates QFA41 Operating voltage AC 24 V / DC 13.5...3 Signal
More informationTraceTek Leak Detection Master Module Installation Instructions TOOLS REQUIRED STORAGE
TTDM-128 TraceTek Leak Detection Master Module Installation Instructions TRACETEK APPROVALS AND CERTIFICATIONS TYPE NM General Signaling Equipment 76LJ GENERAL INFORMATION Please read these instructions
More informationSee instructions to download and install the latest version of LinkBoxMB and the user's manual at
Safety Instructions WARNING Follow carefully this safety and installation instructions. Improper work may lead to serious harmful for your health and also may damage seriously the IntesisBox and/or any
More informationInstallation manual for for Schleifenbauer DPM3
Installation manual for for Schleifenbauer DPM3 Installatie handleiding voor Schleifenbauer DPM3 Installationsanleitung für Schleifenbauer DPM3 Guide d installation du Schleifenbauer DPM3 Installation
More informationOPERATION AND MAINTENANCE MANUAL
OPERATION AND MAINTENANCE MANUAL WA-1 MINI Product code: 304-01-01 *Explanatory figure Table of Contents 1. Manufacturer... 3 2. Specifications... 3 3. Transport and storage... 3 4. Device construction...
More informationETM-2050/ETM-2051 Service Manual
Introduction Novar s Electronic Thermostat Modules (ETMs) are intelligent control modules that provide local, direct digital control of unitary, packaged, staged HVAC systems. This document: Describes
More informationTemperature and humidity regulator H3020 H3021 H3023 H3027. Instruction Manual
Temperature and humidity regulator H3020 H3021 H3023 H3027 Instruction Manual Table of content 1. GENERAL SAFETY RULES... 3 2. GENERAL DESCRIPTION... 4 3. REGULATOR MOUNTING AND CONNECTION... 4 4. DESCRIPTION
More informationINSTALLATION DKM-409 NETWORK ANALYSER WITH HARMONIC MEASUREMENT AND SCOPEMETER. Before installation:
DKM-409 NETWORK ANALYSER WITH HARMONIC MEASUREMENT AND SCOPEMETER The DKM-409 is a precision instrument designed for displaying various AC parameters in 3-phase distribution panels. Thanks to its isolated
More informationthanos RS485 Modbus Application Functions Multifunction Room Operating Unit Datasheet
thanos RS485 Modbus Multifunction Room Operating Unit Datasheet Subject to technical alteration Issue date: 16.09.2015 603591 Application The thanos touch screen room operating unit has integrated temperature
More informationSAMURAI SCAN 50 LED-SC50D. User Guide. Innovation, Quality, Performance. Professional Entertainment Technology 19-
SAMURAI SCAN 50 LED-SC50D Innovation, Quality, Performance User Guide Professional Entertainment Technology 19- EC Declaration of Conformity We declare that our products (lighting equipments) comply with
More informationSoft Starter Remote Operator. Section 1.0 Introduction 1.1 Important user information General Manual description...2.
Section 1.0 Introduction 1.1 Important user information... 2 1.2 General... 2 1.3 Manual description...2 Contents Section 2.0 Specification 2.1 General technical data...3 2.2 Dimensions...3 Section 3.0
More informationADC7520 SERIES. 1600W Battery Chargers and Power Supplies
ADC7520 SERIES 1600W Battery Chargers and Power Supplies Wide output adjustment range 0 72VDC Analog control by external 0-5VDC voltage Temp.comp charging, sense as on option Power fail relay alarm Master-Slave
More informationL Series Humidity/-temperature sensors for use in heating, ventilation and air conditioning Technical data Humidity
Galltec Mess- und Regeltechnik GmbH MELA Sensortechnik GmbH Boschstr. 4 Raasdorfer Str. 18 71145 Bondorf. Germany 07987 Mohlsdorf-Teichwolframsdorf. Germany Tel. +49 (0)7457-9453-0 Tel. +49(0)3661-62704-0
More informationChameleon Stand-alone
Quick Installation Guide Installation and Commissioning Chameleon Stand-alone Power Supply Module, 48 VDC, 650W, HE, IP65 Low Power Outdoor Applications 356849.03 Introduction Warnings..., page 3 Tools
More informationIGLOO IGLOO EASY INSTRUCTION MANUAL
ENGLISH EASY C695 C698 INSTRUCTION MANUAL PRELIMINARY Congratulations on choosing a Clay Paky product! We thank you for your custom. Please note that this product, as all the others in the rich Clay Paky
More informationPMCG - MANUAL PMCG ORIGINAL INSTRUCTIONS. Preservatech Europe sp z o.o. Równa 1, Bydgoszcz, Poland
PMCG ORIGINAL INSTRUCTIONS Manufactured: Designed: Preservatech Europe sp z o.o. Równa 1, 85-846 Bydgoszcz, Poland info@preservatech.eu Preservatech Inc Toronto, Canada info@preservatech.com 1 www.preservatech.com
More informationUSER S GUIDE. EE210 - Humidity and Temperature Transmitter for demanding Climate Control Applications GENERAL
USER S GUIDE EE210 - Humidity and Temperature Transmitter for demanding Climate Control Applications GENERAL The EE210 transmitter, available for wall or duct mounting, is designed for the highly accurate
More informationSolConeX extra-low voltage flange socket
SolConeX extra-low voltage flange socket Operating instructions Additional languages www.stahl-ex.com Contents 1 General Information...3 1.1 Manufacturer...3 1.2 Information regarding the operating instructions...3
More informationInstallation manual plugs and connectors with screw connection (16/32 A)
EN Installation manual plugs and connectors with screw connection (16/32 60003213 Issue 04.2016 2016-04-01 Table of contents 1 About this manual 3 1.1 Structure of the warnings 3 1.2 Symbols used 4 1.3
More informationLED W RGBA User Manual
LED- 245-1W RGBA User Manual Please read the instructions carefully before use CONTENTS 1. Safety Instructions...2 2. Technical Specifications...3 3. How To Set The Unit...4 3.1 Control Panel...4 3.2 Main
More informationHygroClip M22 Series. 2-wire loop powered humidity temperature transmitters INSTRUCTION MANUAL
HygroClip M22 Series 2-wire loop powered humidity temperature transmitters INSTRUCTION MANUAL 20060329 CONTENTS Overview... 3 Operation... 5 Power supply... 5 HygroClip S digital probe... 5 Temperature
More information1. Safety Precautions
2 Contents 1. Safety Precautions... 4 2. General Information... 5 3. Getting started... 6 4. Operation... 7 5. Specifications... 8 6. Maintenance... 9 7. Warranty and Claims... 10 8. EU Declaration of
More informationSee instructions to download and install the latest version of LinkBoxEIB and the user's manual at
Safety Instructions WARNING Follow carefully this safety and installation instructions. Improper work may lead to serious harmful for your health and also may damage seriously the IntesisBox and/or any
More informationRTD-NET Installation Instructions
LED3 SW1 LED4 RTD-NET Installation Instructions 0V +V POWER 15-24VDC English RTD-NET Installation Instructions 100.00 RTD-NET Control Interface realtime Control Systems REMC P1 P2 RS485 D-BUS DB DA GND
More informationT2214. Instruction Manual
Programmable atmospheric pressure transmitter T2214 with 0 to 10 V output Instruction Manual Instruction manual for use of T2214 device Device is designed for measurement of atmospheric pressure at hpa,
More informationUltrasound Controller DP36 Level Switch PSF Manual
Ultrasound Controller DP36 Level Switch PSF Manual AQ M-Tech AB 2 Ultrasound Controller DP36 Level Switch PSF Manual Manual Rev 2.2 DP36 Rev G Gsd file DP360E68.gsd Rev 1.1 Software Version 2.4 January
More informationINSTALLATION MANUAL. LC 200 Electronic Overload Guard. Software versione PW0501 R 0.3
INSTALLATION MANUAL LC 200 Electronic Overload Guard Software versione PW0501 R 0.3 CONTENTS MAIN FEATURES LC 200 TECHNICAL FEATURES Page 2 SYMBOLS Page 3 WARNINGS Page 3 IDENTIFICATION DATA PLATE Page
More informationBW-108. Building Wash BW-108. User Guide. Advanced LED Technology
Building Wash User Guide Advanced LED Technology TABLE OF CONTENTS 1. Safety Instruction 2. Technical Specification 3. Change Beam Angle 4. Main Function 5. How To Control The Unit 6. Troubleshooting 7.
More informationT2314, T2414. Instruction Manual
Atmospheric pressure transmitter T2314, T2414 with RS232 / RS485 serial output Instruction Manual Instruction Manual Device type Pressure Output Galvanic isolated output T2314 RS232 - T2414 RS485 Device
More informationPlease read the instructions carefully before use LED PYRAMID LED-904D. Innovation, Quality, Performance 15-
Innovation, Quality, Performance 15- LED PYRAMID LED-904D User Manual Please read the instructions carefully before use Innovation, Quality, Performance 15- LED PYRAMID LED-904D User Manual Please read
More informationLZR - U920/-U921. LASER MEASUREMENT DEVICE with bidirectional bus communication. User s Guide for product version 0500 and more
EN LZR - U920/-U92 LASER MEASUREMENT DEVICE with bidirectional bus communication User s Guide for product version 0500 and more 2 LASER MEASUREMENT DEVICE Other use of the device is outside the permitted
More informationProcon A1M. INSTALLATION MANUAL Version MITSUBISHI ELECTRIC FOR INSTALLERS
Procon A1M FOR INSTALLERS INSTALLATION MANUAL Version 1.1.1 For safe and correct use, please read this installation manual thoroughly before installing the PROCON A1M. MITSUBISHI ELECTRIC Preface Safety
More informationSee instructions to download and install the latest version of LinkBoxEIB and the user's manual at
Safety Instructions WARNING Follow carefully this safety and installation instructions. Improper work may lead to serious harmful for your health and also may damage seriously the IntesisBox and/or any
More informationModel HU-224/225. Technical Information TI.224/ Humidity Transduce r FOR ADDITIONAL INFORMATION SEE HU-224/225 DATA SHEET
Model /225 FOR ADDITIONAL INFORMATION SEE /225 DATA SHEET SPECIFICATIONS Accuracy*: ± 2% / ± 3% RH Range: 0-100% RH Hysteresis: ± 1% Supply Voltage:12-40 VDC 12-35 VAC (VDC output units only) Supply Current:
More informationVC3000 Series Line Voltage Switching Relay Pack Controllers Installation Guide
Beyond Comfort VC3000 Series Line Voltage Switching Relay Pack Controllers Installation Guide August 10 th, 2010 (For Commercial and Lodging HVAC Fan Coil Applications) 028-0296-R1-LIT-VC3000-E01 Index
More informationLCD LCDS LCDRI CONTROLLER OPERATING MANUAL
This manual contains important safety information about installation and use of this equipment. Ignoring this information could result in injuries or damages. It is strictly forbidden to use this equipment
More informationRoom unit with PPS2 interface
1 642 Desigo RX Room unit with PPS2 interface for use with: QAX33.1 devices of the ranges Desigo RXC, RXB, RXL, and RXA (PPS2) Desigo PX Automation stations 1) devices with a PPS2 interface Room temperature
More informationConfigurable Network Paging Console. Product Instructions. Model: X-NPMI
Configurable Network Paging Console Product Instructions Model: X-NPMI Safety Guidelines Danger This sign reminds users of dangerous voltage on the product. Caution This sign reminds users of important
More informationRXM39.1. PL-Link IO Block. Desigo TRA. Use with PXC3 series room automation station
s 3 836 3836P01 Desigo TRA PL-Link IO Block Use with PXC3 series room automation station RXM39.1 The PL-Link IO Block contains the inputs and outputs controlled by a room automation station via PL-Link.
More informationPolymer Electric. Operating Instructions. Control Unit SG-TRS 3X8. Version 1
Operating Instructions Control Unit SGTRS 3X8 Version 1 100597 SGTRS 318 110 V= 100596 SGTRS 38 4 V= Original instructions GmbH & Co KG Örlinger Straße 1 3 89073 Ulm GERMANY Tel: +49 731 0610 Fax: +49
More informationAGROWtEK Technology to Help You Grow
Specifications Input Power Digital Intelligent Dry-Contact Relay 12-24Vdc Max Switching Current 10A per point Max Switching Voltage 120Vac Independent Contacts 8x Normally Open Status Indicators Red LEDs
More informationDP2500 DP0250. Differential Pressure Transmitter. Product Bulletin
DP2500 DP0250 Differential Pressure Transmitter Product Bulletin The DP Low Differential Pressure Transmitter series is an accurate and cost competitive solution for measuring low pressures of air and
More informationEE80 Series. HVAC Room Transmitter and Switches for CO 2, Relative Humidity and Temperature EE80. Applications. Typical
EE80 Series HVAC Room Transmitter and Switches for, Relative Humidity and Temperature EE80 series set new standards in measurements for HVAC. The transmitters resp. switches combine, relative humidity
More informationSapling Converter Box
Installation Manual Sapling Converter Box SCB-100-000-1 Version Number 1.2 Current as of March 15, 2015 The Sapling Company, Inc. (+1) 215.322.6063 P. (+1) 215.322.8498 F. 2-Wire Converter Box (SCB-100-000-1)
More information60W Power over Ethernet Waterproof Adapter PoE IEEE BT Single Port Injector for Outdoor Application
WWW.PHIHONG.COM 60W Power over Ethernet Waterproof Adapter PoE IEEE BT Single Port Injector for Outdoor Application Features Compliant with the IEEE802.3bt Standard Non-Vented Case with Mounting Bracket
More informationProduct manual plug, sockets and coupler 16 A.- Z0251
Product manual plug, sockets and coupler 16 A.- Z0251 INDEX ELEKTRO BV Harregatplein 15 3214 VP Zuidland Netherlands T. +31(0)181 452120 http/www.indexelektro.nl email info@indexelektro.nl Purpose of these
More informationAir Quality Solutions
Air Quality Solutions Installation & Maintenance Manual Model: DPT-IQ Flow Meter with Backlit Display II-DPT-IQ-1218/Replaces II-DPT-IQ-818 ALL STATED SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT PRIOR
More information