1 PowerWAVE 5000/TP (10 50 kva) Technical Specification 13
2 DOCUMENT CONTROL PDF ISSUE DATE REVISION SUMMARY TS_657_00 20/06/15 Initial published copy TS_657_01 20/0/17 Output current specification error corrected TS_657_02 19/02/19 Kohler rebranding Useful Contacts Kohler Uninterruptible Power Ltd. web site Service department booking service, fault reporting etc. Technical queries Hardware sales Extended warranty agreements etc All product, product specifications and data are subject to change without notice to improve reliability, function, design or otherwise. Kohler Uninterruptible Power Ltd. has taken every precaution to produce an accurate, complete and easy to understand specification document and will assume no responsibility nor liability for direct, indirect or accidental personal or material damage due to any misinterpretation of, or accidental errors, in this manual Kohler Uninterruptible Power Ltd. This manual may not be copied or reproduced without written permission of Kohler Uninterruptible Power Ltd.
3 POWERWAVE 5000/TP SYSTEM DESCRIPTION The availability of protected and continuous power is essential in today s dynamic IT and process-related environments, where demands can change rapidly through the introduction of new server technologies, migration and centralisation. In environments such as these, not only must the power protecting equipment be reliable but it must also be resilient and easily adaptable to suit changing load requirements attributes that are readily apparent in the PowerWAVE 5000/TP series Uninterruptible Power Supply (UPS). The PowerWAVE 5000/TP represents a completely new generation of mid-range, 3 phase UPS systems, incorporating the latest technological developments in power engineering. Its advanced double conversion, Voltage and Frequency Independent (VFI), topology fully satisfies the highest availability and environmentally-friendly requirements compliant with IEC (VFI-SS-111) standards. High reliability, upgrade ability, low operating costs and excellent electrical performance are just some of the highlights of this innovative UPS solution. The PowerWAVE 5000/TP is designed to respond to the most stringent safety, EMC and other important UPS standards. PowerWAVE 5000/TP is a stand-alone UPS module available in seven power ranges: 10, 15, 20, 25, 30, 40 & 50 kva. Each PowerWAVE 5000/TP module can operate as a stand-alone UPS, or up to 20 units can be connected in parallel to operate as a multi-module UPS system. A parallel system configuration is generally chosen either to increase the system s total output power capacity, or to provide module redundancy to enhance the overall system reliability. When operating in a parallel system, each UPS module can assume the paralleling control leadership role which avoids a single point of failure in the parallel chain and ensures the highest level of reliability. Note: Although the UPS single/multi configuration can be modified in the field it is generally specified on ordering so that the module can be configured and fully tested in the factory prior to despatch. The most demanding IT infrastructures begin with low power requirements which gradually increases as it builds up to full capacity. To avoid putting the load at risk, it is essential to be able to increase the amount of available power as the infrastructure grows. The modular design of the PowerWAVE 5000/TP system allows the parallel configuration to be expanded to cater for increasing load demands without interrupting the load or temporarily transferring it to an unprotected bypass supply. This Technical Specification provides detailed technical information on the mechanical, electrical and environmental performance of the PowerWAVE 5000/TP that can support and give answers to tender and end user requirements. KEY FEATURES Best-in-class efficiency Compact size, small foot print Blade-server-friendly power; full power from 0.9 lead to 0.73 lag Very low input current harmonic distortion THDi = load Input Power Factor near unity Energy-Operational cost savings (TCO) Expensive floor space savings No de-rating required with leading PF loads Gen-set power and installation cost savings Cost savings during installation and the entire life cycle (TCO) TS_ PW5000/TP Technical Specification 19/2/19 1
4 GENERAL SPECIFICATIONS MECHANICAL CHARACTERISTICS UPS CABINET A (without battery enclosure) Dimensions (WxHxD) mm 345 x 720 x 710 Weight without battery kg Weight with 4x7/9Ah battery kg Weight with standard packaging kg +4 Colour Black (RAL 9005) UPS CABINET B (without battery enclosure) Dimensions (WxHxD) mm 345 x 1045 x 710 Weight without battery kg Weight with 96x7/9Ah battery kg Weight with standard packaging kg +5 Colour Black (RAL 9005) UPS CABINET C (without battery enclosure) Dimensions (WxHxD) mm 440 x 1420 x 910 Weight (7/9Ah cab without battery) kg Weight (2Ah cab without battery) kg Weight with 144x7/9Ah battery kg Weight with 4x2Ah battery kg Weight with standard packaging kg +5 Colour Black (RAL 9005) INPUT CHARACTERISTICS Input Voltage V 3x30/220V+N, 00V/230V+N, 15/240V+N Input Voltage Tolerance (ref to 00/230V) for Loads in %: V (-23%/+15%) 3x30/177 V to 60/264 V for <100% load (-30%/+15%) 3x20/161 V to 60/264 V for < 0% load (-40%/+15%) 3x240/13 V to 60/264 V for < 60% load Input Frequency Hz Input Power Factor 100% load Inrush Current A max. In Input Distortion THDi Sine-wave THDi = 100% load Max. Input Power with rated output power and charged battery (output pf = 0.9) Max. Input Current with rated output power and charged battery (output pf = 0.9) kw A TS_ PW5000/TP Technical Specification 19/2/19
5 Max. Input Power with rated output power and discharged battery (output pf = 0.9) Max. Input Current with rated output power and discharged battery (output pf = 0.9) kw A OUTPUT CHARACTERISTICS Output Rated Power kva Output rated kva (400 V) A Output Rated Power KW Output rated kw (400 V) A Output Rated Voltage V 3x30/220V or 00/230V or 15/240V Output Voltage Stability % Static: < ±1% Dynamic (Step load 0%-100% or 100%-0%) < ±4% Output Voltage Distortion % With Linear Load < 2% With Non-linear Load (EN :2001) < 4% Output Frequency Hz 50 Hz or 60 Hz Output Frequency Tolerance Bypass operation Deg. Synchronized with mains < ±2% (selectable for bypass operation) or < ±4% Free running ±0.1% At input voltage of 00 V ±15%, or 196 V to 264 V ph-n Permissible Unbalanced Load (All 3 phases regulated independently) % 100% Phase Angle Tolerance (With 100% Unbalanced load) Deg. ±0 deg. Overload Capability on 0. p.f. % 125% load 10 min. 150% load 1 min. Overload Capability on 0.9 p.f. % 110% load 10 min. 130% load 1 min. Output short capability (RMS) A Inverter: up to 3 x In during 40 ms Bypass: 10 x In during 10 ms Crest - Factor 3: 1 HEAT DISSIPATION (Non-linear Loads) Heat Dissipation with 100% Non-linear Load per range (EN ) Heat Dissipation with 100% Non-linear Load per range (EN ) Airflow (25 C - 30 C) with 100% Nonlinear Load per range (EN ) W BTU/h m³/h Heat Dissipation without load W TS_ PW5000/TP Technical Specification 19/2/19 3
6 BATTERY CHARACTERISTICS Cabinet Type A B A B A B B C C C C Maximum Battery Charger Current 4A 6A Battery Charging Curve Ripple free; IU (DIN 41773) Temperature compensation ready Battery Test Battery Type Standard (temp. sensor optional) Automatic and periodically (adjustable) Maintenance free VRLA or NiCd Min/Max Number of 12V Battery Blocks per string 22-50* 32-50* 32-50* 40-50* 24-50* 32-50* 40-50* * Depending on the effective load in kw used by the system (numbers shown are for pf only) Description 10kVA 15kVA Cabinet Type A B A B Maximum Power [kw] Minimum number of battery blocks per string Maximum No. 7/9Ah battery blocks in cabinet Description 20kVA 25kVA Cabinet Type A B B C Maximum Power [kw] Minimum number of battery blocks per string Maximum No. 7/9Ah battery blocks in cabinet Maximum No. 2Ah battery blocks in cabinet N/A N/A N/A Description 30kVA 40kVA 50kVA Cabinet Type C C C Maximum Power [kw] Minimum number of battery blocks per string Maximum No. 7/9Ah battery blocks in cabinet Maximum No. 2Ah battery blocks in cabinet 4 TS_ PW5000/TP Technical Specification 19/2/19
7 COMMUNICATION OPTIONS STANDARD ITEMS Power Management Display (PMD) LCD display and mimic diagram showing UPS operational status JD1 RS232 on Sub-D9 port For monitoring and integration in network management X1 Customer Interfaces: Inputs (DRY PORTS) 1 Remote Shut down [EMERGENCY OFF (Normally closed)] 1 GEN-ON (Normally open) 1 Programmable Customer's Inputs (Normally open) 1 Battery Temperature Sensor for enhanced battery charging control 1 12Vdc source (max. 250mA) to supply remote monitor JR1 RJ45 port For multidrop purpose (optional) OPTIONAL ITEMS Relay card +USB Including: X2 Customer Interfaces: Outputs (DRY PORTS) RS232 on USB Port SNMP Card (slot already included) Common Alarm Load on Bypass Battery Low Load on Inverter Mains Failure For remote signalling and automatic computer shutdown For monitoring and integration into network management ENVIRONMENTAL Audible Noise with 100% / 50% Load dba 55/49 55/49 57/49 57/49 5/50 59/50 59/50 Operating temperature C 0-40 Battery temperature C 20 Battery Storage Time Max. 6 months Max. altitude (above sea level) m 1000m (3300ft) without de-rating De-rating factor for use at altitudes above 1000m sea level according (IEC ) ALL MODULES Metres above sea level (m / ft) De-Rating Factor for Power 1500 / / / / Relative Air-humidity Positional Clearances Accessibility (Operator) Max. 95% (non-condensing) Front: A minimum of 900mm should be allowed for free passage. Side: 600mm left and right side access is required for service. Rear: A minimum of 200mm is required for cooling air circulation and the unit should be cabled such that it can be pulled forward to allow 600mm rear clearance for service/maintenance. 10kVA 25kVA in type A or B cabinets require front/rear access 25kVA 50kVA in type C cabinets require front access only TS_ PW5000/TP Technical Specification 19/2/19 5
8 ENVIRONMENTAL Input and Output Power Cabling Efficiency AC-AC up to (at pf=1.0) (depending on UPS power) 10kVA 25kVA in type A or B cabinets are cabled at the rear 25kVA 50kVA in type C cabinets are cabled at the front Load: 100% 75% 50% 25% Efficiency: 95.5% 95.5% 95% 94.5% ECO Mode efficiency at 100% load % 9% STANDARDS Safety Electromagnetic Compatibility IEC/EN :2003, IEC/EN :2001/A11:2004 IEC/EN :2005, IEC/EN :2000, IEC/EN :2001, EMC Classes C2 domestic or industrial In < 16A C3 industrial In >16A Performance Product certification C2 IEC/EN :2001 CE C3 Degree of protection IP 20 6 TS_ PW5000/TP Technical Specification 19/2/19
9 COMMUNICATION OPTION DETAILS Power management display (PMD) Mimic LED Indicators Power Management Display (PMD) Mimic LED Indicators Alarm & Reset The user-friendly Power Management Display provides access to all monitoring information and operator controls. Mimic Diagram The mimic diagram contains multi-coloured LEDs that change between Green, Red and Off to indicate the UPS operation and power flow status. LEDs LINE 1 and LINE 2 indicate the availability of the input mains and bypass mains power supplies respectively, and are both Green during normal operation. The INVERTER and BYPASS LEDs indicate which of the two power sources is providing the critical load supply. These LEDs illuminate Green to indicate which is the active supply source. The BATTERY LED indicator is a solid Green when the battery is being charged and flashes when the battery is discharging e.g. when it is providing the load power following a mains failure. The ALARM LED, located at the lower-centre area of the PMD, is a visual indication of any monitored internal or external alarm condition. When activated, it is accompanied by an audible alarm that can be cancelled by pressing the RESET button. LCD Display Panel The 2 x 20 character multi-function LCD Display is menu-driven using the UP, DOWN and ENTER keys. It provides a simple communications interface that enables the operator to monitor important UPS operating parameters and alarm warnings, and effect various control operations such transferring the load between the inverter and bypass. LCD Display Panel summary: Displays the input and output voltage, current, frequency and power Displays an Event register which stores a date/time stamped history of the 99 most recent alarms Enables battery run time monitoring Enables selection of commands such as UPS Start-up and Shut-down, Load transfer from inverter to bypass and vice-versa Provides diagnostic facilities (service mode only) In conjunction with the operator keys, provides UPS adjustments and testing facilities (service mode only) JD1 Smart Port Serial RS 232 and USB Port Menu Navigation & Selection Buttons Module ON/OFF Control Buttons JD1is a standard D-Type, 9-pin, female socket, and the USB is a standard USB port. The SMART PORT is an intelligent RS 232 serial port that allows the UPS to be connected to a computer. When used in conjunction with the optional SMART PORT software, WAVEMON, it enables the computer to continuously monitor the mains voltage and UPS-status, and display a message in the event of any UPS system changes. TS_ PW5000/TP Technical Specification 19/2/19 7
10 X1 Dry Port (volt-free contacts) All the input and output interface connections to X1 are made to Phoenix terminals (cable 0.5mm²) Connection of Remote Shut down facilities, Generator Operation, Customers specials. Terminal Contact Signal Function X1/1 In +12Vdc GENERATOR OPERATION X1/2 Gnd Gnd (NC = Generator ON) X1/3 In +12Vdc Customer IN 1 X1/4 Gnd Gnd (Function on request, to be defined) X1/5 In +3.3Vdc BATTERY TEMPERATURE X1/6 Gnd Gnd If connected, the battery charger current is temperature dependent X1/7 In +12Vdc REMOTE SHUTDOWN X1/ Gnd Gnd Do not remove the factory mounted bridge until an external remote shut down is connected X1/9 In +12Vdc 12Vdc SOURCE X1/10 Gnd Gnd Max 200mA load (e.g. used to power remote indicator panels) JR1 RS45 Interface for multidrop The Computer Interface JR1 is an intelligent RS45 serial port that allows system information to be gained from all modules that are connected in parallel using the Multidrop connection kit. The connector JR1 is a standard RJ45 socket. X2 Dry Port Optional output interfaces terminal block (X2) All the input and output interface connections to X2 are made to Phoenix terminals (cable 0.5mm²) X2 provides status and alarm signal outputs that can be used to initiate orderly shutdown of servers, AS400 or automated building management systems. All signals are provided via voltage free contacts are rated 60 VAC / 500 ma maximum. Pin Contact Signal Function 1 NO Alarm MAINS_OK Mains Present 2 NC Mains Not Present 3 Com Common 4 NO Message LOAD_ON_INV Load On Inverter 5 NC Load Not On Inverter 6 Com Common 7 NO Alarm BATT_LOW Battery Low NC Battery OK 9 Com Common 10 NO Message LOAD_ON_MAINS Load On Mains 11 NC Load Not On Mains 12 Com Common 13 NO Alarm COMMON_ALARM Common Alarm 14 NC No Alarm Condition 15 Com Common TS_ PW5000/TP Technical Specification 19/2/19
11 Modem/Ethernet card / PowerREPORTER management software UPS systems Optional Interface Card MODEM SSL INTERNET Communication Interface (PLC s) 1.10 Management Station Alarm Situation Problem in the System Call back Modem GSM Modem Network interface (ethernet) MODEM Co mmunication Interface (PLC s) INTERNET PowerREPORTER PowerREPORTER is a remote monitoring and management service which is a part of the premium power protection concept. Two solution cards are available to enable connection between the UPS and the outside world: Modem/ Ethernet or Modem/GSM. PowerREPORTER : Provides affordable, continuous monitoring over mission-critical facilities and offers peace-of-mind by detecting and warning of any potential system problems before they become a crisis: Acquires key performance parameters and productivity information in real-time to enable you to better understand machine performance and faster troubleshoot downtime events. Gives total transparent information concerning all actions performed on the system, such as all critical status changes, coordination of equipment service, reporting of all alarms with priorities. Key Features Redundant and secure communication Alarm acknowledgment Priority driven Management (with escalation) Comprehensive Management System Reception and management of alarm calls from UPS Storage of UPS Data in a database exportable in a CSV-format for easy handling in Excel Unlimited number of UPS that can be managed User administration with passwords and permission-level Administration of Log file Data logging with statistical analysis and diagnostics, report Visualization of the UPS data Current status ( single and parallel operation) Measured values for single or three phase Recording function including graphs with zooming capabilities for selected measured values Display of event log file Display of UPS Parameters Web Server functionality, for data access from any Web Browser TS_ PW5000/TP Technical Specification 19/2/19 9
12 SNMP card/adaptor for network management/remote monitoring UPS External SNMP Adapter Ethernet Internal SNMP Card The Simple Network Management Protocol (SNMP) is a world-wide standardised communication-protocol that is used to monitor any device in a network via a simple control language. The UPS-Management Software (WAVEMON) provides data in this SNMP format with its internal software agent and can be used with any SNMP compatible operating system. We offer our software with SNMP functionality together with NetWare, OS/2, all Windows NT systems on INTEL and ALPHA. There are two types of SNMP-Adaptors available: External SNMP-Adaptor and Internal SNMP-Card (both have the same functionality). Both can manage a parallel system (N modules) and return either global values which are consistent for the whole parallel system or specific values from the individual modules. The SNMP adaptor requires a PC with terminal connections, and for normal operation at least one network connection (Ethernet) is also required. 10 TS_ PW5000/TP Technical Specification 19/2/19
13 INSTALLATION PLANNING The following guidelines should be taken into account when planning a suitable UPS location and environment. Location considerations summary The equipment must be installed and transported in a upright position The floor at the installed location and en-route from the off-loading point must be able to safely take the weight of the UPS and battery equipment The floor material where the UPS is to be located should be non-flammable Local fire protection standards must be respected Ensure that appropriate power supplies are available and that UPS cabling can be performed easily The location must be vibration free If the UPS is to be installed in bayed enclosures, partition walls must be installed. Environmental considerations summary Avoid high ambient temperature, moisture and humidity. Humidity (< 90% non-condensing) and temperature (+15 C / +25 C) are within prescribed limits A temperature of 20 C is recommended to achieve a long battery life. Any prescribed air cooling flow must be available. Ensure the air conditioning system can provide a sufficient amount of air cooling to keep the room at, or below, the maximum desired temperature. Ensure no dust or corrosive/explosive gases are present CLEARANCES X Y* V Y* X BATTERY CABINET (option) UPS Front Front Access Space V 600 mm X 600 mm Z Z Y* 200 mm Z 900 mm The above diagram illustrates the recommended clearances to be provided around the UPS and optional Battery Cabinet. Please read the following notes for clarification. Notes 1. The minimum 200mm space shown at the rear of the UPS [Y] is required to allow adequate cooling air flow; however, A and B UPS cabinets are cabled from the rear and the UPS power switches and fuses are located on the back panel. When installing A and B UPS cabinets you should allow sufficient slack in the cabling to pull the UPS cabinet forward or otherwise install the UPS with sufficient rear clearance to allow cable and switch access. 2. The above diagram shows 600mm clearance [V] between the UPS and optional Battery Cabinet. This is necessary to gain side access to the UPS for service repair. In the case of a type A or B UPS cabinet, if the cabling is sufficient to allow the cabinet to be pulled forward clear of the Battery Cabinet (see note 1 above) then it is not necessary to observe clearance [V], and the UPS and Battery Cabinets can be located immediately adjacent to each other. TS_ PW5000/TP Technical Specification 19/2/19 11
14 UPS POWER CABLING Cabinets A & B (10-25kVA) All power cables are connected to terminals on the bottom of the UPS Power Board accessed through a removable panel on the lower back of the UPS. Ex. Batt. Earth Input Mains Bypass Mains UPS Output Earth + N PE 1L2 1N 2L2 2N 3L2 3N PE PE 1L1 1L3 2L1 2L3 3L1 3L3 PE Cabinet C (25-50kVA) All power cables are connected to terminal blocks mounted on a DIN rail located in the lower front of the UPS. + N 1L1 1L2 1L3 1N PE 3L1 3L3 PE PE 2L1 2L2 2L3 2N 3N 3L2 PE Terminal Connections Battery (+ / N / - / PE) Input Bypass (3 + N) Input Mains (3+N+PE) Output Load (3+N+PE) Max Cable Section Tightening Torque Cabinets A & B (10-25kVA) 4 x 16mm² 5 x 16mm² 16mm² 1.5 Nm Cabinet C (25-50kVA) 4 x 35mm² 5 x 35mm² 16mm² 3.5 Nm The UPS input/bypass terminals should be connected to the input mains/bypass supply through a LV-Distribution board and protected by a circuit breaker or fuse. This provides overload protection and also a means of isolating the UPS from the mains supply when required. Similarly, the UPS output terminals should be connected to the load equipment via a suitably fused load distribution panel. Note: It is the customer s responsibility to provide all external fuses, isolators and cables used to connect the UPS input and output power supplies. The UPS can be wired with a single feed input (standard), whereby the UPS input supply is internally connected to the UPS bypass circuit, or it can be wired with a dual feed input (shown above) where the UPS bypass circuit is connected to a dedicated bypass supply. Where a single feed is used, the Input Mains and Bypass terminals are linked together on the UPS power connector blocks. The following diagram identifies the UPS input/output cabling requirements and provides information regarding the necessary fuse and cable ratings, and cable sizing. 12 TS_ PW5000/TP Technical Specification 19/2/19
15 Fuses & Cables Quick Reference SINGLE INPUT FEED (standard) Fuse A Mains (3x30/220V, 00/230V, 15/240V) DUAL INPUT FEED Fuse B Fuse C Cable A Cable B Cable C FA1 FA2 FA1 FA2 FA3 (F1) Rectifier FA3 (F1) Rectifier FA4 Inverter FA4 Inverter EXTERNAL BATTERY CABINET (option) Internal Batts. Static Switch Output Switch IA2 Maint. Bypass IA1 EXTERNAL BATTERY CABINET (option) Internal Batts. Static Switch Output Switch IA2 Maint. Bypass IA1 Single input feed Load Cable D Load Cable D Power (kva) Fuse A (Agl/CB) (A) Cable A (mm²) Cable D (mm²) 10 3 x 20 5 x x x 32 5 x x x 40 5 x x x 40 5 x x x 63 5 x 10 5 x x 0 5 x 25 5 x x 0 5 x 25 5 x 25 Dual input feed Power (kva) Fuse B (Agl/CB)(A) Cable B (mm²) Fuse C (Agl/CB)(A) Cable C (mm²) Cable D (mm²) 10 3 x 20 5 x x 20 5 x x x 32 5 x x 32 5 x x x 40 5 x x 40 5 x x x 40 5 x x 40 5 x x x 63 5 x 10 3 x 63 5 x 10 5 x x 0 5 x 25 3 x 0 5 x 25 5 x x 0 5 x 25 3 x 0 5 x 25 5 x The fuse and cable rating details in the above tables are a recommendation only. 2. The UPS must be installed to prescribed IEC or local regulations (e.g. BS7671:200). 3. External DC Cables and Battery fuses are bespoke to the installation. TS_ PW5000/TP Technical Specification 19/2/19 13
DPA UPSCALE TM RI kw Technical Specifications
DPA UPSCALE TM RI 10-80 kw Technical Specifications Edition 18.06.2012 Copyright 2015 ABB, All rights reserved. TABLE OF CONTENTS 10.1 DPA UPScale RI SYSTEM DESCRIPTION... 3 10.2 TECHNICAL CHARACTERISTICS
More informationConceptpower DPA TM S kva Technical Specifications
Conceptpower DPA TM S2 30-250 kva Technical Specifications Copyright 2015 ABB, All rights reserved. Section-10 TABLE OF CONTENTS 10.1 CONCEPTPOWER DPA SYSTEM DESCRIPTION... 3 10.2 TECHNICAL CHARACTERISTICS...
More informationConceptpower DPA TM Technical Specifications
Conceptpower TM Technical Specifications Conceptpower TM highlights at a glance with Safe-Swap Modules (SSM) For premium power protection availability Low total Cost of Ownership (TCO) Cost saving during
More informationTechnical Specification Minipower Plus
Technical Specification Minipower Plus Pioneering solutions for total power protection MINIpowerUPS SYSTEM DESCRIPTION Using a unique modular construction, the MINIpowerUPS model range represents a completely
More informationPowerWAVE 6000 Series kva Technical Specification
PowerWAVE 6000 Series 3 60-120 kva Technical Specification INTRODUCTION Continuous power availability is essential in today s dynamic IT and process-related work environments. It is equally important that
More informationTechnical Data Sheets Uninterruptible Power Supply LP11 Series UPS kva
GE Critical Power Technical Data Sheets Uninterruptible Power Supply LP11 Series UPS 3 5 6 8 10 kva GE Consumer & Industrial SA General Electric Company CH 6595 Riazzino (Locarno) Switzerland T +41 (0)91
More informationUPS TRIFASE kVA Rev. 8 Serie TPH IGBT
RS232, RS485, USB, remote panel LCD, with SNMP software. series represents the latest generation of UPS in three-phase high-power transformer (VFI-SS-111) designed to protect a wide area of critical applications.
More information1PH RACK 19 SINGLE PHASE UPS Rev. 11 SR 6kVA 10kVA
The SR series on line double conversion UPS with full time Digital Signal Processor control technology is the perfect solution for mission critical users who demand high reliability, availability and performance
More informationEst ComPower Mini. Compact UPS kva
Est.1968 ComPower Mini Compact UPS 7.5 40 kva Cabinet A: Up to 15kVA with 10 min. Cabinet B: Up to 40kVA with 10 min. Cabinet C: Up to 40kVA with 20 min. ComPower Mini The Beauty of Power Protection Simplicity
More informationTHOR Modular. Modular UPS system. Online double-conversion Scalable Decentralized Parallel. Modular. 10, 20, 30, 40kVA modules kVA systems
Power Supplies Modular THOR Modular Modular UPS system Online double-conversion Scalable Decentralized Parallel Modular 10, 20, 30, 40kVA modules 10-520kVA systems Power factor 1.0 at 10/20kVA/kW modules
More informationthe Centric 300 An advanced modular UPS up to 1800kVA/kW
the Centric 300 An advanced modular UPS up to 1800kVA/kW 1 Gamatronic, Israel s Leading Power Electronics Company True to the exceptional reputation earned by Israeli technology companies, Gamatronic has
More informationEst FlexiPower Maxi. Modular UPS kw
Est.1968 FlexiPower Maxi Modular UPS 8 200 kw Modular Parallel Architecture for missioncritical applications The rapid growth of data centers with mission critical applications that are fundamentally immune
More informationSingle phase UPS. Applications. Highlights. 1ph from 450 VA to 10 kva. Home Office Computers and peripherals Networks and servers Small data centers
Single phase UPS 1ph from 450 VA to 10 kva Applications Home Office Computers and peripherals Networks and servers Small data centers Highlights User-friendly and Plug and Play Compact and noiseless Intuitive
More informationPowerWAVE (6-10kVA) Technical Specification
PowerWAVE 1000 (6-10kVA) Technical Specification Document Control PDF ISSUE DATE REVISION SUMMARY TS_651_00A 01/08/2017 Draft copy A TS_651_00B 07/08/2017 Draft copy B TS_651_00C 11/08/2017 Draft copy
More informationUPS. centric Hot scalable modular 3-phase UPS Delivers 25 up to 200 kva/kw INFINITE POWER. Mission Critical Applications
INFINITE POWER Mission Critical Applications UPS UNINTERRUPTIBLE POWER SUPPLY centric Hot scalable modular 3-phase UPS Delivers 25 up to 200 kva/kw Rack-mountable modules designed for blades, data-center,
More informationTel: AC Power for Business-Critical Continuity TM
Tel: +852-2690-4118 AC Power for Business-Critical Continuity TM Anticipating Technology Changes Through Adaptive Architecture Today, you need a power infrastructure that can work across your enterprise
More informationLEVELUPS T3. SERIES kva ONLINE UPS 3:3 PHASE VFI TYPE. Highest Reliability and Robust Protection for Industrial Loads
LEVELUPS T SERIES DATA CENTER MEDICAL TRANSPORT INDUSTRY EMERGENCY VFI TYPE PF= 0.9 Service UPS ONLINE TOWER POWER FACTOR SERVICE HIGHLIGHTS Built In Inverter Transformer for DC-AC Galvanic Protection
More informationR E C T I F I E R I N V E R T E R C O N V E R T E R MP7
Uninterruptible Power Supply Product Specifications Description The industrial UPS provides your critical equipment with uninterruptible 3 phase AC power. Using high frequency dual conversion technology,
More informationKeor HPE UPS THREE-PHASE UPS. from 60 to 200 kw GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES
Keor HPE UPS THREE-PHASE UPS from 60 to 200 kw GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES LEGRAND UPS SERVICE continuity ENERGY efficiency SUPERIOR PERFORMANCES Legrand, world
More informationDistributed by. Keor T UPS THREE-PHASE UPS. from 10 to 120 kva GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES
Distributed by Keor T UPS THREE-PHASE UPS from 10 to 120 kva GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES T THREE-PHASE UPS T has been designed with advanced technologies and the
More informationPowerWAVE 9250DPA. ( N+1 kva/kw) Parallelable up to 1.5 MVA/MW
PowerWAVE 9250DPA (50 250 N+1 kva/kw) Parallelable up to 1.5 MVA/MW True modular UPS for medium power applications in critical, high-density computing environments such as small to medium-sized data centres,
More information10 kva 3/1 15 kva 3/1 20 kva 3/1 10 kva 3/3 15 kva 3/3 20 kva 3/3 30 kva 3/3 40 kva 3/3 UOUS SERV WARRANTY
OF CONTINUOUS SERVICE YEARS WARRANTY B8000 FXS 10-40kVA BORRI B8000 FXS With disturbances to the electrical supply being one of the major causes of IT downtime, the UPS system is regarded as the most critical
More informationGalaxy VM. 160/200 kva Parallel capable up to 800 kva. Three-phase power protection. Galaxy VM trusted partner for your business continuity
Galaxy VM 160/200 kva Parallel capable up to 800 kva Three-phase power protection Galaxy VM trusted partner for your business continuity Highly efficient, easy-to-deploy, three-phase power protection that
More informationMP7. Uninterruptible Power Supply
Uninterruptible Power Supply PRODUCT SPECIFICATIONS Description The industrial UPS provides your critical equipment with uninterruptible 3 phase AC power. Using high frequency dual conversion technology,
More informationUPS Sentry MPS. SENTRY MPS is also compatible with different battery technologies: openvase lead acid and AGM and Gel VRLA, NiCd.
Quality Power Supply SENTRY MPS is an on-line double conversion (VFI SS 111 in accordance with IEC EN 620406-3) with a transformer isolated inverter. With a compact footprint and high power quality output,
More informationKeor HPE UPS. THREE-PHASE UPS from 60 to 300 kw GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES
Keor HPE UPS THREE-PHASE UPS from 60 to 300 kw GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES LEGRAND UPS SERVICE continuity ENERGY efficiency SUPERIOR PERFORMANCES Legrand, world
More informationSmartOnline SVTX Series 3-Phase 380/400/415V 30kVA 27kW On-Line Double-Conversion UPS, Tower, Extended Run, SNMP Option
SmartOnline SVTX Series 3-Phase 380/400/415V 30kVA 27kW On-Line Double-Conversion UPS, Tower, Extended Run, SNMP Option MODEL NUMBER: SVT30KX Highlights On-line double-conversion topology, VFI operation
More informationModular three-phase UPS system. Conceptpower DPA kva True modular UPS system for critical applications
Modular three-phase UPS system Conceptpower DPA 10 250 kva True modular UPS system for critical applications A UPS designed to meet the needs of today and tomorrow The Conceptpower DPA is a high-power,
More informationEst FlexiPower Maxi UPS FPX Maxi kVA
Est.1968 FlexiPower Maxi UPS FPX Maxi 50 250kVA True modular UPS system for critical applications Designed and Published by Thycon. A UPS DESIGNED TO MEET THE NEEDS OF TODAY AND TOMORROW The FlexiPower
More informationPostfach 2327, Offenburg * Helmholtzstr. 13, Offenburg. Technical Data. Model protecto ER
On-line UPS-system according to DIN EN 62040-3 (VFI-SS-111) with sinus soidal output voltage in each operation mode, RS232 interface and Shutdown-Software for Windows NT/2000/XP/2003/Vista, Novell and
More informationLiebert NXr Series 30kVA to 160kVA. AC Power for Business-Critical Continuity TM
Liebert NXr Series 30kVA to 160kVA AC Power for Business-Critical Continuity TM Anticipating Technology Changes Through Adaptive Architecture Today, you need a power infrastructure that can work across
More informationGAMATRONIC, A SolarEdge Division.
GAMATRONIC, A SolarEdge Division. 17 Hartum Street, POB 45029, Jerusalem 9777517,Israel Tel: +972-2-5888222 Fax: +972-2-5828875 e-mail: info@gamatronic.com www.gamatronic.com The Power+ Premium 60 is
More informationGalaxy VX. From 500 to 1500 kw N+1 Parallel solutions up to 4000 kw 380V / 400V / 415V / 440V. schneider-electric.com/ups
Galaxy VX Highly efficient, scalable, three-phase power protection with flexible operating modes and ECOnversion for large facilities, data centers, and business-critical applications. From 500 to 1500
More informationLiebert GXT MT kva
Liebert GXT MT+ 10-20 kva Liebert GXT MT+ UPS, 10 kva - 20 kva Intelligent, Reliable UPS Protection Liebert GXT MT+ is a true on-line UPS that delivers continuous, high-quality AC power to connected equipment
More informationPOWERVAR SECURITY PLUS SERIES DETAILED UPS SPECIFICATION (8kVA 10kVA)
POWERVAR SECURITY PLUS SERIES DETAILED UPS SPECIFICATION (8kVA 10kVA) A55-00017 SEC PLUS 8-10 KVA MAREKTING SPECS REV. A 9/10 8kVA, 10kVA POWERVAR Isolated On-Line UPS Specifications Index 1.0 General
More informationLEVELUPS T3 3 UPS. SERIES kva ONLINE UPS 3:3 PHASE VFI TYPE. Highest Reliability with Embedded Isolation Transformer
LEVELUPS T SERIES DATA CENTER MEDICAL TRANSPORT INDUSTRY EMERGENCY Three LEVEL UPS VFI TYPE PF=.0 Service UPS ONLINE TOWER POWER FACTOR SERVICE HIGHLIGHTS True Three Level Rectifier and Inverter Technology
More informationLiebert NX - Next Generation UPS for protecting your Business Critical Systems. AC Power Systems for Business-Critical Continuity
- Next Generation UPS for protecting your Business Critical Systems AC Power Systems for Business-Critical Continuity Advanced UPS Technology Protects Modern IT Equipment Today s advanced digital computing,
More informationALL PSU Ltd ROTATION+ 6kVA - 10kVA PARALLEL ON LINE DOUBLE CONVERSION
ALL PSU Ltd Unit D6 Laser Quay, Culpeper Close Medway City Estate, Rochester, Kent, ME2 4HU Phone: 01634-725527 Fax: 01634-739111 E-mail: sales@allpsu.co.uk Web: www.allpsu.co.uk ROTATION+ 6kVA - 10kVA
More informationEaton 9EHD Industrial UPS
Power Quality Solution Eaton 9EHD Industrial UPS Effective power management for every harsh environment Innovation design for the most demanding applications Eaton s rugged products, innovative designs
More informationUninterruptible Power Supplies
Xi Series 1-6kVA True On-Line UPS Features Rack-Mount/Standalone Format Universal Battery Design (Optional 10 year batteries) Dual Mains Input Dual Position Backlit LCD LCD Load Segment Control 2.5kVA
More informationCritical Power 2017 Catalogue
Critical Power 2017 Catalogue UPS for process and service industry UPS for data centers, networks and servers UPS for home and office computers and peripherals Who we are 2 UPS 450-2000 VA Line-interactive
More informationThe Power of Modularity
Protectplus M600 The Power of Modularity to protect critical applications Protectplus M600 Flexible, scalable and smart It s our business to make your power security easy UPS systems from AEG Power Solutions
More informationMODULAR UPS SYSTEM KVA
MODULAR UPS SYSTEM 10-100 KVA True Modularity True Rightsizing True Green Power True On Line GAMATRONIC, A SolarEdge Division 47505 Seabridge Drive, Fremont, CA, 94538 USA Tel: 1-800-277-5496 SalesNA.Gama@solaredge.com
More informationSMARTONLINE E3 UPS SYSTEMS
SMARTONLINE E3 UPS SYSTEMS Extremely efficient protection for your most important equipment IDEAL OUTPUT POWER PROTECTS CRITICAL SYSTEMS On-line, double conversion operation continuously delivers precision-regulated,
More informationSR Plus series. on-line. SR20 Plus SR20T Plus. SR60 Plus LOCAL AREA NETWORKS (LAN) SERVERS DATA CENTERS. Industrial PLCS
SR20 Plus SR20T Plus SR60 Plus SR Plus series on-line UPS 10, 15, 20, 30, 40, 60, 90, 120 kva three phase/three phase LOCAL AREA NETWORKS (LAN) SERVERS DATA CENTERS Cash Registers Telecomunication Devices
More informationIntelligent On-Line UPS
Intelligent On-Line UPS Intelligent On-Line UPS Unity Input Power Factor Single-Chip Microprocessor Control Wide Input Voltage Range Pure Sinewave Output Smart RS-232 Communication Interface External Battery
More informationProduct Specifications
Product Specifications Models: USC-10001, USC-10002 USC-20001, USC-20002 USC-30001, USC-30002 Guide Specification for UniStar C Series Rack/Universal 1, 2, 3Kva Single-Phase, On-Line Double Conversoin
More informationMulti Power x 42 kw up to 1 MW + redundancy 3:3 VFI TYPE. Utmost Availability Ultimate Scalability Unmatching Power Density
DATACENTRE TRANSPORT Multi Power VFI TYPE ONLINE 3:3 Modular 1-28 x 42 kw up to 1 MW + redundancy 6 USB plug SmartGrid ready HIGHLIGHTS Utmost Availability Ultimate Scalability Unmatching Power Density
More informationGalaxy VM. Three-phase power protection. Galaxy VM trusted partner for your business continuity
Galaxy VM Three-phase power protection Galaxy VM trusted partner for your business continuity Highly efficient, easy-to-deploy, three-phase power protection that seamlessly integrates into the electrical,
More informationChloride. FP-60z 5 160kVA 1ph / 3ph Industrial AC UPS System
Chloride FP-60z 5 160kVA 1ph / 3ph Industrial AC UPS System Chloride FP-60z The Chloride FP-60z is a true industrial UPS system offering a full-igbt innovative design and embedding all the latest technologies
More informationMUST900 Modular UPS. Datacenter & servers. Internet centers. Local Area Networks (LAN) Telecommunication devices. Emergency application
MUST900 Modular UPS 30-300 kva modular UPS - up to 900 Datacenter & servers Internet centers Local Area Networks (LAN) Telecommunication devices Emergency application Smart Energy Solutions HOT SWAP 0.9
More informationSmartOnline 10kVA On-Line, Double-Conversion UPS, 6U Rack/Tower, 3-Phase input, 1-Phase output
SmartOnline 10kVA On-Line, Double-Conversion UPS, 6U Rack/Tower, 3-Phase input, 1-Phase output MODEL NUMBER: SU10KRT3/1X Highlights 10,000VA (10kVA) SmartOnline 6U rack/tower UPS 3 phase, 4-Wire + Ground,
More informationLP 33 Series UPS. Digital Energy. GE Digital Energy
GE Digital Energy Digital Energy LP 33 Series UPS 40/60/80/100/120 kva three phase 400 Vac Active IGBT Rectifier & Active IGBT Rectifier Clean Input Module Uninterruptible Power Supply (UPS) imagination
More informationBusiness continuity made easy
Business continuity made easy Schneider Electric Easy UPS 3 Series Easy UPS 3S: 220/230/240/380/400/415V Easy UPS 3M: 380/400/415V schneider-electric.com/ups Business continuity made easy The Schneider
More informationSmartOnline SVX Series 120kVA Modular, Scalable 3-Phase, On-line Double-Conversion 400/230V 50/60Hz UPS System
SmartOnline SVX Series 120kVA Modular, Scalable 3-Phase, On-line Double-Conversion 400/230V 50/60Hz UPS System MODEL NUMBER: SVX120KL Highlights 120kVA / 120kW modular, scalable, 3-phase, Large-Frame tower
More informationZP120N Online UPS. High Power Intensity. Flexibility. High efficiency with low heat dissipation. Smart Energy Solutions
Online UPS 1,2,3,6,10,20 kva single/single-phase and three/single-phase High Power Intensity STRONGEST PERFORMANCE Flexibility High efficiency with low heat dissipation EXTENDABLE AUTONOMY Smart Energy
More informationSATURN DATACENTER & SERVERS TELECOMMUNICATION DEVICE INDUSTRIAL APPLICATION TRANSPORTS. Smart Energy Solutions
10-20 kva single phase/single phase and three phases/single phase 10-200 kva three phases/three phases DATENTER & SERVERS TELECOMMUNICATION DEVICE INDUSTRIAL APPLICATION TRANSPORTS Smart Energy Solutions
More informationATS-16 HV USER MANUAL. Automatic Transfer Switch 16A / 230Vac V090318
ATS-16 HV Automatic Transfer Switch 16A / 230Vac USER MANUAL V090318 SAFETY Intended use The ATS-16 HV device serves as a power source selector to provide improved power supply for connected loads. ATS-16
More informationMAJOR VA Power Inverter
MAJOR500-500 VA Power Inverter The Major500 is a highly reliable, telecom quality, DC to AC power inverter. The Major500 features full electronic protection, high efficiency and low output noise. The built-in
More informationLiebert. APM from 30 to 300 kw. The Compact Row Based UPS With FlexPower Technology
Liebert APM from 30 to 300 kw The Compact Row Based UPS With FlexPower Technology LIEBERT APM from 30 to 300 kw Vertiv Vertiv designs, builds and services mission critical technologies that enable the
More informationARCHIMOD HE 240/480 HIGH POWER MODULAR UPS THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURE
ARCHIMOD HE 240/480 HIGH POWER MODULAR THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURE superior performance continuity of service energy efficiency 2 Legrand, world leader in the
More informationSchneider Electric Easy UPS 3S
Schneider Electric Easy UPS 3S Business continuity made easy 10 40 kva 380/400/415 V schneider-electric.com/ups Schneider Electric Easy UPS 3S The Schneider Electric Easy UPS 3S is an easy-to-install,
More informationMasterNOVA. MasterNOVA (3/1) MasterNOVA 250i - 600i (3/3) MasterNOVA Pro /3)
MasterNOVA MasterNOVA 30-100 (3/1) MasterNOVA 250i - 600i (3/3) MasterNOVA Pro 250-800 3/3) MasterNOVA The MasterNOVA UPS is one of the best performing and reliable UPS from GTEC, providing power protection
More informationMASTERELITE MULTITEC MRM/MRT MRM 10-20kVA single/single phase or three/single phase MRT 10-30kVA three/three phase
MASTERELITE MULTITEC MRM/MRT MRM 10-20kVA single/single phase or three/single phase MRT 10-30kVA three/three phase The MasterElite MultiTec range uses advanced digital online (VFI) technology to support
More informationUPS. ARCHIMOD UPS MODULAR THREE-PHASE from 20 to 120kVA THE GLOBAL SPECIALIST IN ELECTRAL AND DIGITAL BUILDING INFRASTRUCTURES
UPS ARCHIMOD UPS MODULAR THREE-PHASE from 20 to 120kVA THE GLOBAL SPECIALIST IN ELECTRAL AND DIGITAL BUILDING INFRASTRUCTURES Efficiency up to 95% when in ON LINE MODE ARCHIMOD modular three-phase Standard
More informationSmartOnline V 10kVA 7kW Online, Double-Conversion UPS, 6U Rack/Tower, Extended Run, Pre-installed SNMP port, RS232, 3 Phase in-single Phase out
SmartOnline 200-240V 10kVA 7kW Online, Double-Conversion UPS, 6U Rack/Tower, Extended Run, Pre-installed SNMP port, RS232, 3 Phase in-single Phase out MODEL NUMBER: SU10KRT3/1X Highlights 10,000VA (10kVA)
More informationModular UPS S KVA
Scalable 3 - phase, double conversion UPS system with hot-plug design up to 220 KVA (n + 1). The modular design with 20 KVA modules makes any system up or downgrade flexible and avoids high inv estment
More informationPRODUCT BROCHURE. Conceptpower DPA V UL Modular UPS 20kW 600kW
PRODUCT BROCHURE Conceptpower DPA 120 208V UL Modular UPS 20kW 600kW 2 CONCEPTPOWER DPA 120 280V MODULAR UPS Today s data centers require continuous uptime. That target is why ABB s Conceptpower DPA 120
More informationPRODUCT BROCHURE. Conceptpower DPA V UL Modular UPS 100kW 3MW
PRODUCT BROCHURE Conceptpower DPA 500 480V UL Modular UPS 100kW 3MW 2 C O N C E P T P O W E R D PA 5 0 0 4 8 0 V M O D U L A R U P S Today s data centers require continuous uptime. That target is why ABB
More informationLiebert GXT3 5kVA-10kVA UPS Compact UPS Systems For High Power Network Rack Applications. AC Power For Business-Critical Continuity
Liebert GXT3 5kVA-10kVA UPS Compact UPS Systems For High Power Network Rack Applications AC Power For Business-Critical Continuity Liebert GXT3, 5kVA-10kVA UPS Systems: Big Protection, Small Package Today
More informationMODULYS GP Unique, fully modular and redundant solution Green Power 2.0 range from 25 to 600 kva/kw
Unique, fully modular and redundant solution The solution for > Computer rooms > Data centres > Banks > Healthcare facilities > Insurance > Telecom Advantages > Ensures absolute business continuity > Aligns
More informationAPMTM UPS 30kW - 300kW The Compact Row-Based UPS With Flexpower Technology
APM UPS 30kW - 300kW The Compact Row-Based UPS With Flexpower Technology T M LIEBERT APM UPS Anticipating Technology Changes Through Adaptive Architecture Today, you need a power infrastructure that can
More informationHigher Availability: Self-diagnostics. Automatically tests unit electronics and batteries. Designed to simplify maintenance and troubleshooting.
UPS operation and display panel can rotate 90 degrees, which provides upright viewing for users. Liebert GXT3 UPS Includes These Outstanding Features: Flexibility: Rack/tower configuration. The versatile
More informationSmartOnline 240/208/120V 8kVA 5.6kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 4U Rack/Tower, Split-Phase input, Bypass Switch
SmartOnline 240/208/120V 8kVA 5.6kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 4U Rack/Tower, Split-Phase input, Bypass Switch MODEL NUMBER: SU8000RT4U Description Tripp Lite 8kVA SmartOnline
More informationTSP-BCM48, TSP-BCM48A. Operating Instruction Manual. Page 1 of 13
Battery Controller Module TSP-BCM24, TSP-BCM24A TSP-BCM48, TSP-BCM48A Operating Instruction Manual http://www.tracopower.com Page 1 of 13 Dimensions drawings: TSP-BCM24 & TSP-BCM48 Weight: 0.816lb Gewicht:
More informationProduct brochure. Conceptpower DPA Modular UPS DPA 120 UL 208V: 20kW 600kW
Product brochure Conceptpower DPA Modular UPS DPA 120 UL 208V: 20kW 600kW 2 Product brochure Conceptpower DPA 120 UL UPS Conceptpower DPA 120 The modular UPS for small and medium-sized data centers UPS
More informationEaton 9EHD Industrial UPS
Eaton 9EHD Industrial UPS Effective power management for every harsh environment Power Quality Solution poweronaustralia.com.au 1300 662 435 Innovative design for the most demanding applications Eaton
More informationSentinel Dual High Power
VFI TYPE SOHO DAtACeNteR e-medical ONline Sentinel Dual High Power INDUStRY transport emergency 1:1 3:1 3,3-10 kva 6 USB plug Hot swap battery energy share HigHligHtS Simplified installation operating
More informationPowerWAVE 9500DPA 500 kw Modular UPS User Manual
PowerWAVE 9500DPA 500 kw Modular UPS User Manual Document Control ISSUE DATE REVISION SUMMARY Issue 1.0 01-05-14 Initial issue. UPS740-01-00 PowerWave PW9500DPA User Manual - Issue 1.0 (Dated 01-05-14)
More informationCPS kVA TRIFASE EN50171
PRINCIPLES OF WORKING The loads can be divided into two types: 1) Users always powered (SA). the users are always fed both in the presence and absence of the mains. 2) Users powered emergency service only
More informationMGE Galaxy /30/40/60/80/100/120 kva. The recommended power protection for all critical applications.
MGE Galaxy 5000 20/30/40/60/80/100/120 kva The recommended power protection for all critical applications. 20 120 kva state-of-the-art, threephase power protection designed to meet a wide range of requirements
More informationRT4F-48V/50A-WAC RECTIFIER
The RT4F-48V/50A-WAC is a switched mode rectifier (SMR) module designed to provide up to 58A of output current into a 48V nominal system, over a wide range of AC input voltage. This rectifier has been
More informationg GE Power Quality Digital Energy GT Series On-Line, Double Conversion Uninterruptible Power Supply 1000, 1500, 2200, 3000 VA UL-version
GE Power Quality Product Description On-Line, Double Conversion Uninterruptible Power Supply 1000, 1500, 2200, 3000 VA UL-version Manufactured by: GE Digital Energy General Electric Company Telephone 800-637-1738
More informationMasterNOVA. MasterNOVA (3/1) MasterNOVA 250i - 600i (3/3) MasterNOVA Pro /3)
MasterNOVA MasterNOVA 30-100 (3/1) MasterNOVA 250i - 600i (3/3) MasterNOVA Pro 250-800 3/3) MasterNOVA The MasterNOVA UPS is one of the best performing and reliable UPS from GTEC, providing power protection
More informationSirius series. on-line
U.T.E. Electronic GmbH & Co. KG - Friedrich-Ebert-Str. 112a - 58454 Witten Tel.: 02302-282830 - Email: info@ute.de - Internet: www.ute.de Sirius series on-line UPS 10 20 kva single/single phase and three/single-phase
More informationMODULYS GP Unique, fully modular and redundant solution Green Power 2.0 range from 25 to 600 kva/kw
Unique, fully modular and redundant solution The solution for > Computer rooms > Data centres > Banks > Healthcare facilities > Insurance > Telecom Advantages > Ensures absolute business continuity > Aligns
More informationLiebert NX Series. 30kVA to 200kVA. AC Power for Business-Critical Continuity TM
Liebert NX Series 30kVA to 200kVA AC Power for Business-Critical Continuity TM Anticipating Technology Changes Through Adaptive Architecture Today, you need a power infrastructure that can work across
More informationSmartOnline SVX Series 90kVA 400/230V 50/60Hz Modular Scalable 3-Phase On-Line Double- Conversion Medium-Frame UPS System, 5 Battery Modules
SmartOnline SVX Series 90kVA 400/230V 50/60Hz Modular Scalable 3-Phase On-Line Double- Conversion Medium-Frame UPS System, 5 Battery Modules MODEL NUMBER: SVX90KM3P5B Highlights 90kVA/90kW Modular, Scalable,
More informationMUST 900 UPS. Finally the benefits of Modular ups are for all. 3 Phase Modular. Hot swappable, scalable 30kVA to 900kVA
MUST 900 3 Phase Modular UPS Hot swappable, scalable 30kVA to 900kVA Finally the benefits of Modular ups are for all MUST 900 The MUST 900 series is an uninteruptible power supply, three phase input/output,
More informationGE Consumer & Industrial Power Protection. Digital Energy LP Series UPS. Uninterruptible Power Supply 3-30 kva
GE Consumer & Industrial Power Protection Digital Energy LP Series UPS Uninterruptible Power Supply 3-30 kva GE imagination at work For more than a century, GE has led the way with innovative technologies
More informationRT4F-110V/25A RECTIFIER
The RT4F-110V/25A is a hot-pluggable switched mode rectifier (SMR) module designed to provide up to 25A of output current into a 110V nominal system. Examples of such systems are 60 cells lead acid (136V
More informationun I Jet ИБП ABB Conceptpower DPA S2 ( ква) - руководство по эксплуатации. Юниджет
--------- l -' un I Jet, ИБП ABB Conceptpower DPA S2 (30-250 ква) - руководство по эксплуатации. Юниджет Постоянная ссылка на страницу: https://www.uni-jet.com/catalog/istochnikibesperebojnogo-pitaniya/on-line-ibp-100-kva/abb-conceptpower-dpa-series.html
More informationMGE Galaxy /50/60/80/100/130 kva. The recommended power protection for all critical applications
MGE Galaxy 5000 40/50/60/80/100/130 kva The recommended power protection for all critical applications 40 130 kva state-of-the-art three-phase power protection designed to meet a wide range of requirements
More informationSmartOnline SV Series 20kVA Small-Frame Modular Scalable 3-Phase On-Line Double- Conversion 208/120V 50/60 Hz UPS System, No SVBM Battery Module
SmartOnline SV Series 20kVA Small-Frame Modular Scalable 3-Phase On-Line Double- Conversion 208/120V 50/60 Hz UPS System, No SVBM Battery Module MODEL NUMBER: SV20KS1P0B Highlights Scalable capacity up
More informationMGE Galaxy 5000 for emergency lighting and power equipment
MGE Galaxy 5000 for emergency lighting and power equipment UL 924 listed UPS and battery systems schneider-electric.com 2 schneider-electric.com State-of-the-art three-phase power protection designed to
More informationTME Modular Series UPS System kva/kw - 208/220 VAC
GE TME Modular Series UPS System 15-90 kva/kw - 208/220 VAC TME Modular Series UPS 15-90 kva/kw Highest Technology with Modular Design GE s TME Series UPS is one of the most reliable three-phase UL UPS
More informationAIS 3000 APC AIS kVA 400V w/3 Batt. Modules Exp. To 4, Start-Up 5X8, Internal Maintenance Bypass
AIS 3000 APC AIS 3000 10kVA 400V w/3 Batt. Modules Exp. To 4, Start-Up 5X8, Internal Maintenance Bypass APC AIS 3000, 8000 Watts / 10 kva,input 400V 3PH / Output 400V 3PH, Interface Port DB-9 RS-232, Smart-Slot,
More informationHYBRID PV INVERTERS HySpirit Series. 4kW-10kW. Hybrid Inverter with Battery Backup Smart Energy for Smart Home
HYBRID PV INVERTERS HySpirit Series Hybrid Inverter with Battery Backup Smart Energy for Smart Home 4kW-10kW FSP HySpirit series Offers a more intelligent power solution for our customers to reduce the
More informationSchneider Electric Easy UPS 3S
Schneider Electric Easy UPS 3S Business continuity made easy 10 40 kva 380/400/415 V schneider-electric.com/ups Business continuity made easy The Schneider Electric Easy UPS 3S is an easy-to-install, easy-to-use,
More informationZP 120 N. UPS 1,2,3,6,10,20 kva. online LOCAL AREA NETWORKS (LAN) SERVERS DATA CENTERS
online UPS 1,2,3,6,10,20 kva LOCAL AREA NETWORKS (LAN) SERVERS DATA CENTERS INTERNET CENTERS (ISP/ASP/POP) INDUSTRIAL PLCS EMERGENCY DEVICES (LIGHTS, ALARM) ELECTROMEDICAL DEVICES TELECOMMUNICATION DEVICES
More information