Manual TU510A. Auto Transfer Controller HM1043ER1

Size: px
Start display at page:

Download "Manual TU510A. Auto Transfer Controller HM1043ER1"

Transcription

1 Harsen Manual TU510A Auto Transfer Controller HM1043ER1

2 History History No. Rev. Date Editor Validation Changes 1 HM1043ER P.L New Harsen I

3 Contents Contents Description The Outline Dimensional Drawings and wirings of Intelligent Controller Operation Panel Installation Guide Control and Operation Instruction Measure and Display Data Alarm Parameters Setting Communication Function Technical Parameters Troubleshooting Harsen I

4 Description Description TU510A controller is an auto transfer controller, which incorporating the functions such as measuring display, control, and three remote. This controller covers three models: TU510A-MG/MM/GG, respectively used for auto transfer control of the dual power system, such as Mains and Gen, Mains and Mains, Gen and Gen. It has following functions: Micro-computer control, complete digital technology. Select the running mode of controller by buttons on panel. LED directly displays the running status of ATS and the running mode of controller. Configure the running parameters by LED and buttons on panel. Display measuring data by LED, including voltage and frequency. By connecting RS485 communication port to PC (required for RS485/RS232 interface converter) all setting values and data can be read and wrote, and modified. This manual is only suitable for TU510A auto transfer controller; user must carefully read this manual first. The descriptions in this manual, to describe expediently and avoid repetition and redundance, are defined as following: 1. General Designation TU510A-MG TU510A-GG TU510A-MM 1# power source Mains 1# Gen 1# Mains 2# power source Gen 2# Gen 2# Mains 2. Shortened form MG model GG model MM model Models TU510A-MG TU510A-GG TU510A-MM Harsen Page 1/28

5 Outline Dimensional Drawings and wirings 1. The Outline Dimensional Drawings and wirings of Intelligent Controller The controller is closely combined by panel and powder coated steel enclosure, and the panel is die-casting by flame-retarded and high strength plastic. All connections of controller are connected by pin-like and locked up terminal, easier and more convenient to connect, move, maintain and replace the device. 1.1 Following Details: Operation Panel Install Hatch Thickness W205mm x H156mm W186mm x H138mm D60mm(unconnected) NOTE: when using, the controller must be properly grounded, well low impedance grounded can reduce the impact from the processes of surge and transient of the electric power system to the meter. Harsen Page 2/28

6 Outline Dimensional Drawings and wirings 1.2 The Connecting Terminals of MG Model: Pin No. Function Description Signal Dim A1 Mains Ph-A voltage input 0-300VAC 1mm² A2 Mains Ph-B voltage input 0-300VAC 1mm² A3 Mains Ph-C voltage input 0-300VAC 1mm² A4 Mains neutral 1mm² A5 Relay N. O. contact control outputs of transfer switch 1.5mm² A6 Relay COM at Mains side 1.5mm² 10A/250VAC A7 Relay N. C. contact 1.5mm² B8 Working power +B (optional)12v/24v(8-35vdc 1mm² B9 Working power -B continuous) 1mm² C10 Gen Ph-A voltage input 0-300VAC 1mm² C11 Gen Ph-B voltage input 0-300VAC 1mm² C12 Gen Ph-C voltage input 0-300VAC 1mm² C13 Gen neutral 1mm² C14 Relay N. O. contact control outputs of Transfer switch 1.5mm² C15 Relay COM at Gen side 1.5mm² 10A/250VAC C16 Relay N. C. contact 1.5mm² D17 Com. port for status input signal Low potential output 1mm² D18 Mains aux contact signal Low potential is active 1mm² D19 Gen aux contact signal Low potential is active 1mm² D20 reserve Low potential is active 1mm² D21 Generator failure input Low potential is active 1mm² D22 reserve Low potential is active 1mm² D23 Start output {COM} Control generator start output 1mm² D24 Start output {N/O} 5A/30VDC 1mm² D25 Reserve output {COM} Reserve output 1mm² D26 Reserve output {N/O} 5A/30VDC 1mm² D27 externally grounded 1.5mm² Harsen Page 3/28

7 Outline Dimensional Drawings and wirings 1.3 The typical wiring diagram of MG Model Gen (3P&N) L4 L5 L6 N2 F5 F6 F7 F RL F9 (2A) Genset start signal AC resource(standby) (8-35VDC) 27 Load(3P&N) L7 L8 L9 N3 F4 F1 F2 M2 M RL2 RL1 TU510a-MG M1/M2 (aux contact) Note: controller must be grounded properly F3 3 L1 L2 L3 N1 Mains (3P&N) It is used for the transfer switch of TGME or AC connector type. Harsen Page 4/28

8 Outline Dimensional Drawings and wirings Gen (3P&N) L4 L5 L6 N2 F5 F6 F7 F RL2 RL F9 (2A) Genset start signal DC resource(standby) (8-35VDC) Load(3P&N) L7 L8 L9 N3 F4 Note: F1 F2 MT MT (Storage motor) MT MN MN (no voltage) MN XF XF (close) XF MX MX (de-exciter) MX RL1 TU510a-MG M1/M2 (aux contact for transform switch) Note: controller must be grounded properly F3 3 L1 L2 L3 N1 Mains (3P&N) It is used for the transfer switch of breaker type. Harsen Page 5/28

9 Outline Dimensional Drawings and wirings 1.4 The Connecting Terminals of GG Model: Pin No. Function Description Signal Dim A1 1# Gen Ph-A voltage input 0-300VAC 1mm² A2 1# Gen Ph-B voltage input 0-300VAC 1mm² A3 1# Gen Ph-C voltage input 0-300VAC 1mm² A4 1# Gen neutral 1mm² A5 Relay N. O. contact 1.5mm² transfer switch at 1# Gen side A6 Relay COM controls output 10A/250VAC 1.5mm² A7 Relay N. C. contact 1.5mm² B8 Working power +B 12V/24V 1mm² B9 Working power -B (8-35VDC continuous) 1mm² C10 2# Gen Ph-A voltage input 0-300VAC 1mm² C11 2# Gen Ph-B voltage input 0-300VAC 1mm² C12 2# Gen Ph-C voltage input 0-300VAC 1mm² C13 2# Gen neutral 1mm² C14 Relay N. O. contact Control outputs of transfer switch 1.5mm² C15 Relay COM at 2# Gen side output 1.5mm² 10A/250VAC C16 Relay N. C. contact 1.5mm² D17 COM. port for status input signal Low potential output 1mm² D18 1# Gen aux contact signal Low potential is active 1mm² D19 2# Gen aux contact signal Low potential is active 1mm² D20 1# generator failure input Low potential is active 1mm² D21 2# generator failure input Low potential is active 1mm² D22 Remote start input Low potential is active 1mm² D23 2# start output {COM} Control 2# generator start output 1mm² D24 2# start output {N/O} 5A/30VDC 1mm² D25 1# start output {COM} Control 1# generator start output 1mm² D26 1# start output {N/O} 5A/30VDC 1mm² D27 externally grounded 1.5mm² Harsen Page 6/28

10 Outline Dimensional Drawings and wirings 1.5 The typical wiring diagram of GG Model 2# Gen (3P&N) L4 L5 L6 N2 F5 F6 F RL4 RL TO GEN.2 TO GEN.1 Genset start signal 26 Load (3P&N) L7 L8 L9 N3 F8 F4 F1 F2 M2 M RL2 RL1 TU510A-GG F9 (2A) M1/M2 (Aux for switch) 1# 2# Gen fault Gen fault DC source (8-32VDC) Note: controller must be grounded properly F3 3 L1 L2 L3 N1 1# Gen (3P&N) 22 Remote start signal (Short when nonuse) It is used for the transfer switch of TGME or AC connector type. Harsen Page 7/28

11 Outline Dimensional Drawings and wirings 2# Gen (3P&N) L4 L5 L6 N2 F5 F6 F7 F RL2 RL4 RL F9 (2A) TO GEN.2 TO GEN.1 Genset start signal Load(3P&N) L7 L8 L9 N3 Note: F4 F1 MT MT (storage motor) MT MN MN (no voltage) MN XF XF (close) XF MX MX (de-exciter) MX RL1 TU510A-GG M1/M2 1# Gen fault (aux for switch) 2# Gen fault Remote start signal (Short when nonuse) DC source (8-35VDC) Note: controller must be grounded properly F2 F3 2 3 L1 L2 L3 N1 1# Gen (3P&N) It is used for the transfer switch of breaker type. Harsen Page 8/28

12 Outline Dimensional Drawings and wirings 1.6 The Connecting Terminals of MM Model: Pin No. Function Description Signal Dim A1 1# Mains Ph-A voltage input 0-300VAC 1mm² A2 1# Mains Ph-B voltage input 0-300VAC 1mm² A3 1# Mains Ph-C voltage input 0-300VAC 1mm² A4 1# Mains neutral 1mm² A5 Relay N. O. contact 1.5mm² Control outputs of transfer switch A6 Relay COM at 1# Mains side 10A/250VAC 1.5mm² A7 Relay N. C. contact 1.5mm² B8 Working power +B (optional) 12V/24V 1mm² B9 Working power -B (8-35VDC continuous) 1mm² C10 2# Mains Ph-A voltage input 0-300VAC 1mm² C11 2# Mains Ph-B voltage input 0-300VAC 1mm² C12 2# Mains Ph-C voltage input 0-300VAC 1mm² C13 2# Mains neutral 1mm² C14 Relay N. O. contact 1.5mm² Control outputs of transfer switch C15 Relay COM at 2# Mains side 10A/250VAC 1.5mm² C16 Relay N. C. contact 1.5mm² D17 COM. port for status input signal Low potential output 1mm² D18 1# Mains aux contact signal Low potential is active 1mm² D19 2# Mains aux contact signal Low potential is active 1mm² D20 Reserve Low potential is active 1mm² D21 Reserve Low potential is active 1mm² D22 Reserve Low potential is active 1mm² D23 Aux. output {COM} 1mm² Reserve 5A/30VDC D24 Aux. output {N/O} 1mm² D25 Aux. output {COM} 1mm² Reserve 5A/30VDC D26 Aux. output {N/O} 1mm² D27 externally grounded 1.5mm² Harsen Page 9/28

13 Outline Dimensional Drawings and wirings 1.7 The typical wiring diagram of MM Model: 2# Mains (3P&N) Load (3P&N) L7 L8 L9 N3 L4 L5 L6 N2 F5 F6 F7 F8 M RL2 TU510A-MM Note: controller must be grounded properly F4 F1 F2 M RL M1/M2 (Aux for switch) F3 3 L1 L2 L3 N1 1# Mains (3P&N) It is used for the transfer switch of TGME or AC connector type. Harsen Page 10/28

14 Outline Dimensional Drawings and wirings 2# Mains (3P&N) L4 L5 L6 N2 F5 F6 F7 F8 MT MN XF MX RL2 Note: controller must be grounded properly Load(3P&N) L7 L8 L9 N3 Note: MT (Storage motor) MN (no voltage) XF (close) MX (de-exciter) TU510A-MM M1/M2 (Aux for switch) MT MN XF MX F RL1 F1 F2 F L1 L2 L3 N1 1# Mains (3P&N) It is used for the transfer switch of breaker type. Harsen Page 11/28

15 Operation panel 2. Operation panel The operation panel covers three sections: measuring parameters displayed by LED, operating buttons and running states displayed by LED. 2.1 LED display and control buttons 3-digit LED in 2 rows at the both sides respectively display one phase voltage and frequency of either power in the dual power system, and scroll page can review other phase voltage. LED combined with control buttons provide a friendly operation interface for operator to set operating parameters. Function Description Tag Enter into submenu/modify/confirm modification Scroll up menu/ value ascend Scroll down menu/ value descend Harsen Page 12/28

16 Operation panel 2.2 The Operating Buttons and LED of MG Model Function Description Tag AUTO button/led This button is used for AUTO mode setting, when controller in this mode, the LED above the button lights up. Mains is prior, when Mains is normal, power supply by Mains; when Mains failure occurs, power supply by Gen. MAN button/led This button is used for MAN mode setting. When controller in this mode, the LED above the button lights up. Controller will choose power supply by Mains or Gen by pressing TO MAINS or TO GENSET button. TEST button/led This button is used for testing mode setting. When controller in this mode, the LED above the button lights up. In this mode, controller simulates Mains failure. TO MAINS button When controller in MAN mode and Mains voltage is normal, press this button can switch to Mains supply, the LED above the button lights up. TO GENSET button When controller in MAN mode and Gen voltage is normal, press this button can switch to Gen supply, the LED above the button lights up. L. TEST button Lamp testing button, when press this button all lamps on panel should light up, otherwise, failure occurred. Note: the illuminating of LED above TO MAINS and TO GENSET buttons indicates the related closing relay action. Harsen Page 13/28

17 Operation panel 2.3 The Operating Buttons and LED of GG Model Function Description Tag GEN.1 button/ LED This button is used for 1# Gen. prior mode setting. LED above the button lights up when controller running in this mode. 1# Gen. is prior. When 1# Gen. is normal, power supply by 1# Gen.; if 1# Gen failure occurs, power supply by 2# Gen. MAN button LED This button is used for MAN mode setting. LED above the button lights up when controller is running in this mode. Controller selects power supply by 1# Gen. or 2# Gen. by pressing To GEN.1 or To GEN.2. GEN.2 button/ LED This button is used for 2# Gen. prior mode setting. LED above the button lights up when running in this mode. 2# Gen. is prior. When 2# Gen. is normal, power supply by 2# Gen.; if 2# Gen failure occurs, power supply by 1# Gen. TO GEN.1 button When controller in MAN mode and 1# Gen voltage is normal, press this button can switch to 1# Gen supply. TO GEN.2 button When controller in MAN mode and 2# Gen voltage is normal, press this button can switch to 2# Gen supply. L. TEST button Lamp testing button, when press this button all lamps on panel should light up, otherwise, failure occurred. NOTE: the illuminating of LED above TO GEN.1 and TO GEN.2 buttons indicates the related closing relay action. Harsen Page 14/28

18 Operation panel 2.4 The Operating Buttons and LED of MM Model Function Description Tag MAINS1 button/ LED This button is used for 1# MAINS prior mode setting. LED above the button lights up when controller running in this mode. 1# MAINS is prior. When 1# MAINS is normal, power supply by 1# MAINS; if 1# Gen failure occurs, power supply by 2# MAINS. MAN button LED This button is used for MAN mode. LED above the button lights up when controller is running in this mode. Controller select power supply by 1# MAINS or 2# MAINS by pressing To MAINS1 or To MAINS2. MAINS2 button/ LED This button is used for 2# MAINS prior mode setting. LED above the button lights up when controller running in this mode. 2# MAINS is prior. When 2# MAINS is normal, power supply by 2# MAINS; if 2# MAINS failure occurs, power supply by 1# MAINS. TO MAINS1 button When controller in MAN mode and 1# MAINS voltage is normal, press this button can switch to 1# MAINS supply. TO MAINS2 button When controller in MAN mode and 2# MAINS voltage is normal, press this button can switch to 2# MAINS supply. L. TEST button Lamp testing button, when press this button all lamps on panel should light up, otherwise, failure occurred. NOTE: the illuminating of LED above TO MAINS1 and TO MAINS2 buttons indicates related closing relay action. Harsen Page 15/28

19 Installation Guide 3. Installation Guide 3.1 Panel Installation The controller is fixed by 4 special screws. The shock-proof equipment must be installed, if the enclosure that installed on controller is directly installed on Genset body or other heavy vibrant device. 3.2 Please read drawing or above Typical Wiring Diagram for wiring connecting. Harsen Page 16/28

20 Control and Operation Instruction 4. Control and Operation Instruction There are three control modes for each controller: Model Mode 1 Mode 2 Mode 3 TU510A-MG Auto Man Test TU510A-GG 1# Gen prior Man 2# Gen prior TU510A-MM 1# Mains prior Man 2# Mains prior 4.1 Operation Mode Setting Operation Description MG GG MM Press AUTO / GEN.1 / MAINS1 button (continue 2s), LED above the button lights up; controller is running in the mode of Auto/1# Gen prior/1# Mains prior. Press MAN button (continue 2s), LED above the button lights up; controller is running in MAN mode. Press TEST / GEN.2 / MAINS2 button (continue 2s), LED above the button lights up; controller is running in the mode of Test/2# Gen prior/2# Mains prior. NOTE: Only 1 mode can be selected from above 3 modes. 4.2 The Control Process of AUTO transfer for MG Model (in AUTO operation mode) : Operation Description When controller is in AUTO state, Mains on delay begins counting, if Mains is normal, when time out, transfer switch closes Mains immediately, power supply by Mains, Mains supply LED lights up. Mains Va=220V F=50.0HZ Gen Va=0 V F=0.0HZ When Mains failure is confirmed after alarm delay or Mains Gen controller is in TEST state, output Genset start signal to control Genset s start. When Genset data such as voltage and frequency all reach setting values, Gen. on delay begins Va=0 V Va=220V counting. When time out, transfer switch closes Gen immediately, power supply by Gen, Gen supply LED lights up. F=0.0HZ F=50.0HZ NOTE: When controller is not switched on DC working power, the start signal stays at closing state. When switch on Mains, and the controller stays at AUTO state, the start signal will break after the setting cooling delay. If Mains failure occurs, controller stays at the state of loss power and no display. The start signal closes at the same time, it controls generator to start, the controller resumed to display when the normal voltage has been set up. Harsen Page 17/28

21 Control and Operation Instruction 4.3 The Control Process of MAN transfer for MG Model: Operation Description When controller is running in MAN state, Mains is normal, press TO MAINS button (continue 2S), transfer switch will close Mains, power supply by Mains, and LED for Mains supply lights up. When controller is running in MAN state, Gen is normal, press TO GENSET button (continue 2S), transfer switch will close Gen, power supply by Gen, and LED for Gen supply lights up. NOTE: After output the power supply transfer signal, if the transfer switch can not stay at Mains supply or Gen supply status, the transfer signal will keep on output until controller s power supply by Gen or Mains is abnormal, then it is cut off. 4.4 The Control Process of AUTO transfer for GG Model (in 1# Gen prior operation mode) : Operation When the remote start signal is active, 1# start signal closes, when 1# Gen voltage is normal, 1# Gen on delay begins counting, when time out, the switch closes, power supply by 1# Gen and its LED lights up. Description 1# Gen 2# Gen Va=220V Va=0 V F=50.0HZ F=0.0HZ When 1# generator failure input is active, output 2# start signal after confirming. when 2# Gen voltage is normal, 2# Gen on delay begins 1# Gen 2# Gen counting, when time out, transfer switch auto transfer, power supply by 2# Va=0 V Va=220V Gen and its LED lights up. LED displays the values of voltage and frequency. F=0.0HZ F=50.0HZ NOTE: For GG model, 1# or 2# prior running time can be set by TEC parameter. When remote start signal is active, if the controller has been in 1# prior mode, it will auto transfer to 2# prior mode after the TEC setting time expires, after another the TEC setting time will auto transfer back to 1# prior mode, and following the cycle. If the setting value is 0, it will not auto transfer. 4.5 The Control Process of MAN transfer for GG Model : Operation Description When controller is running in MAN state, if 1# Gen is normal, press TO GEN.1 button (continue 2S), transfer switch will close 1# Gen, power supply by 1# Gen, and LED for 1# Gen supply lights up. When controller is running in MAN state, if 2# Gen is normal, press TO GEN.2 button (continue 2S), transfer switch will close 2# Gen, power supply by 2# Gen, and LED for 2# Gen supply lights up. NOTE: After output the power supply transfer signal, if the transfer switch can not stay at 1# Gen supply or 2# Gen supply status, the transfer signal will keep on output until controller s power supply of 1# Gen or 2# Gen is abnormal, then it is cut off. Harsen Page 18/28

22 Control and Operation Instruction 4.6 The Control Process of AUTO transfer for MM Model (in 1# Mains prior operation mode) : Operation when 1# Mains voltage is normal, 1# Mains on delay begins counting, when time out, the switch closes, power supply by 1# Mains and its LED lights up. During 1# Mains supply, 1# Mains failure occurs and is confirmed after alarm delay, if 2# Mains voltage is normal then 2# Mains on delay begins counting, when time out, transfer switch auto transfer, power supply by 2# Mains and its LED lights up. LED displays: Description 1# Mains 2# Mains Va=220V Va=0 V F=50.0HZ F=0.0HZ 1# Mains 2# Mains Va=0 V Va=220V F=0.0HZ F=50.0HZ when 1# Mains voltage is normal, 1# Mains supply delay begins counting, when time out, transfer switch auto transfer, power supply by 1# Mains and its LED lights up. 4.7 The Control Process of MAN transfer for MM Model : Operation Description When controller is running in MAN state, if 1# Mains is normal, press TO MAINS1 button (continue 2S), transfer switch will close 1# Mains, power supply by 1# Mains, and LED for 1# Mains supply lights up. When controller is running in MAN state, if 2# Gen is normal, press TO MAINS.2 button (continue 2S), transfer switch will close 2# Mains, power supply by 2# Mains, and LED for 2# Mains supply lights up. NOTE: After output the power supply transfer signal, if the transfer switch can not stay at 1# Mains supply or 2# Mains supply status, the transfer signal will keep on output until controller s power supply of 1# Mains or 2# Mains is abnormal, then it is cut off. Harsen Page 19/28

23 Measure and Display Data 5. Measure and Display Data 1# power source three phase voltage V Va, Vb, Vc 1# power source frequency Hz F (Measure the frequency of L1) 2# power source three phase voltage V Va, Vb, Vc 2# power source frequency Hz F (Measure the frequency of L1) Harsen Page 20/28

24 Alarm 6. Alarm 1# Source High Voltage When any phase voltage of 1# source exceeds the 1# source high voltage alarm setting value, which is confirmed after delay, 1# source high voltage failure, making related closing relay output. 1# Source Low Voltage When any phase voltage of 1# source falls below the 1# source low voltage alarm setting value, which is confirmed after delay, 1# source low voltage failure, making related closing relay output. 1# Source High Frequency When the frequency of 1# source exceeds the 1# source high frequency alarm setting value, which is confirmed after delay, 1# source high frequency failure, making related closing relay output. 1# Source Low Frequency When the frequency of 1# source falls below the 1# source low frequency alarm setting value, which is confirmed after delay, 1# source low frequency failure, and making related closing relay output. 2# Source High Voltage When any phase voltage of 2# source exceeds the 2# source high voltage alarm setting value, which is confirmed after delay, 2# source high voltage failure, making related closing relay output. 2# Source Low Voltage When any phase voltage of 2# source falls below the 2# source low voltage alarm setting value, which is confirmed after delay, 2# source low voltage failure, making related closing relay output. 2# Source High Frequency When the frequency of 2# source exceeds the 2# source high frequency alarm setting value, which is confirmed after delay, 2# source high frequency failure, making related closing relay output. 2# Source Low Frequency When the frequency of 2# source falls below the 2# source low frequency alarm setting value, which is confirmed after delay, 2# source low frequency failure, making related closing relay output. Generator Failure When controller detects generator failure signal input, stop start signal output immediately, making related closing relay output. NOTE: All alarms of high voltage, low voltage, high frequency, and low frequency are voltage failures. Harsen Page 21/28

25 Parameters Setting 7. Parameters Setting No. Item Default Value Range 01 Address 1 1~ # source low volt alarm AC198V AC45~220V /0 not set 03 1# source high volt alarm AC253V AC110~265V/999 not set 04 1# source low freq alarm 45.0Hz 45~60HZ /0 not set 05 1# source high freq alarm 57.0Hz 50~70HZ/99.9 not set 06 1# source alarm delay 5 s 0~250 s 07 1# source on delay 5 s 0~250 s 08 1# generator cooling delay GG 300 s 0~999 s 09 2# source low volt alarm AC198V AC45~220V /0 not set 10 2# source high volt alarm AC253V AC110~265V/999 not set 11 2# source low freq alarm 45.0Hz 45~60HZ /0 not set 12 2# source high freq alarm 57.0Hz 50~70HZ/99.9 not set 13 2# source alarm delay 5 s 0~250 s 14 2# source on delay 5 s 0~250 s 15 2# generator cooling delay MG/GG 300 s 0~999 s 16 Auto transfer time GG 0 h 0.0~99.9 h 17 Transfer mode MG 0 0~2 18 Default Settings 19 Quit NOTE: NO. 08 and NO.16 are only available for GG model, other models will span this item, the same that NO.15 also only available for MG/GG, other items are common used for each model. In order to make sure above menus are active, must confirm that the working power is normal. When adopting AC working power, if voltage is abnormal, since controller can not normally display, the related alarm delay is inactive, the working power is required to change to DC supply. Auto-transfer time (TEC): TEC set the prior running time of 1# or 2#. If controller has been in 1# prior mode, after Gen running expires the TEC setting time, it will auto transfer to 2# prior mode, after anther TEC setting time it will auto transfer to 1# prior mode, and following the cycle, if the setting value is 0, it will not auto transfer. Transfer mode (TSM): There are three kinds of transfer modes applied in the MG model. Set at 0 is for auto change and auto recovery mode, which is Mains failure and start Gen. on, when Mains resume to normal transfer to Mains on. Set at 1 and 2 are for auto change without auto recovery modes, when set at 1 Gen. on after Mains failure, It will not transfer whether Mains is normal or Gen. failure, it is equal to MAN state, when set at 2 Gen. keeps on supply after Mains failure until Gen failure, if Mains resume to normal transfer to Mains on. The configuration and modification for parameters adopt gradually increase and decrease, when continuously press increase or decrease button, the unit digit changed one by one, then the tens digit changed after ten unit digit changed, follow this logic, and the hundreds digit changed after ten. Continuously press 2s can enter into setting status, use and scroll page up and down at that time. Press enter into modify, key in password (2213). Harsen Page 22/28

26 Parameters Setting For Example: (Set controller 1# source low volt alarm value at 175V) Operation Button Description Continuously press LED displays: 2s, enter into setting menu, Press once, then press once, LED displays: After pressing, it prompts to key in password: At the time can press to modify parameters, LED displays: After finishing modification, continuously press can quit setting status. 2s For Example: (Set controller 1# source on delay at 10s) Operation Button Description Continuously press LED displays: 2s, enter into setting menu, Press 6 times, then press once, LED displays: After pressing, it prompts to key in password: At the time can press to modify parameters, LED displays: After finishing modification, continuously press can quit setting status. 2s For Example: (resume all parameters of controller to factory default) Operation Button Description Continuously press LED display: 2s, enter into setting menu, Continuously press until displays DEF, press once again, LED displays: According to the prompt, key in, then press. After finishing modification, continuously press setting status. 2s can quit The setting and operation method for other parameters are similar to above method. Harsen Page 23/28

27 Communication Function 8. Communication Function (It is an optional function, user can confirm whether equip or not according to detailed condition) 8.1 Brief Introduction The controller has an RS CONNECTOR communication interface, if the interface is equipped with CI485A(CI232A)communication interface module, then controller has RS485/RS232 industrial standard COM immediately. The communication interface adopts photoelectricity seclusion design and has circuit protection function to prevent interference from common module voltage and damage result by error connection, the RS485 adopts 9600 baud rate. The controller that has communication function has following features: 100% remote signaling function, including running status and failure status. 100% telemetering data, including all measuring data of controller. 100% remote control function, covers all control functions on panel. 100% remote regulating, including all settable parameters of controller. 8.2 The Communication Connection for CI485 Controller has RS485 COM after adding CI485A accessory, following typical wiring diagram: TU510A Controller RS CONNECTOR (DB9) CI485A 8.3 The Communication Connection for CI232A Controller has RS232 COM after adding CI232A accessory, following typical wiring diagram: TU510A Controller RS CONNECTOR (DB9) CI232A CI232A Transform A B S (RS485) Can link separately MODEM PC Harsen Page 24/28

28 Communication Function 8.4 The Communication Connection for Multi Controllers The communication interface offers user a route: from which you can get more information that can not obtain from panel, the matching software can display all measured parameters and status information, and can set all parameters. The controller that has RS485 COM allows 1 communication bus can mostly connect 247 same series of controllers by wiring connection mode. Each device has only one ID NO., and only can be connected to PC or MODEM by matching with another RS485/RS232 shifter in that time. Following typical wiring diagram: CI485A CI485A A R to risistance PC B S RS CONNECTOR RS CONNECTOR RS CONNECTOR (DB9) (DB9) (DB9) TU510A Controller TU510A Controller TU510A Controller CI485A A A A RS485/232 Transformer MODEM can connect seperately B S B S B S NOTE: Communication cable used high quality shielded twisted-pair cable, and its amount length must not exceed 1000m. The anode and cathode of RS485 in each controller must be correctly connected, and the cable shield only can be grounded at one side. Harsen Page 25/28

29 Communication Function 8.5 Communication Protocol RS485 mechanism is a kind of network format of character stream signal through between computer and hardware device. When controller is working, it adopts 9600 baud rate and MODBUS-RTU communication protocol. When it is working, computer will send out a string of instruction to controller and then waiting for the return data string. NOTE: the maximum word amount of read and write, read is 16, write is 14, and write only can use continued write command 10(hex). Controller Data Cell Address Address Word Contents Unit $ Remote Control Order 01: MAN transfer to 1# source 02: MAN transfer to 2# source 05: enter into test/ 2# source prior operation mode 06: enter into MAN status 07: enter into auto/ 1# source prior operation mode 09: lamp test $ # source C phase voltage V $ # source B phase voltage V $ # source A phase voltage V $ # source frequency 0.1Hz $ # source C phase voltage V $ # source B phase voltage V $ # source A phase voltage V $ # source frequency 0.1Hz Bit0 1# source close instruction $ Bit1 2# source close instruction Bit2 1# generator failure Bit3 2# generator failure Bit4 remote start Bit8 1# close output Bit9 2# close output Bit10 1# start output Bit11 2# start output Digital input Relay output $100A 1 Serial number SN $ Communication address $ # source low V failure value V $ # source high V failure value V $ # source low Hz failure value 0.1Hz $ # source high Hz failure value 0.1Hz $ # source failure confirmation time S $ # source on delay S $ # Gen cooling delay (only at GG model is active) S $ # source low V failure value V $200A 1 2# source high V failure value V $200B 1 2# source low Hz failure value 0.1Hz 0.1Hz $200C 1 2# source high Hz failure value 0.1Hz 0.1Hz $200D 1 2# source failure confirmation time S $200E 1 2# source on delay S $200F 1 2# Gen cooling delay (only at MG/GG model is active) S Harsen Page 26/28

30 Technical Parameters 9. Technical Parameters Working voltage: AC85-265V (The internal power supply is from the A-phase of the dual power, dispenses with additional power) or 12V/24V (8-35VDC continuous) controller defaults AC supply (except GG). Max power consumption: <3W Measure AC voltage input: V (ph-n) true RMS AC measure accuracy: 0.5 level The measure range of frequency: 45-65Hz Using ambient temperature: -20 to 50 Storage ambient temperature: -40 to 80 Switch control relay output: 10A/250VAC Aux. relay output: 5A/250VAC/30VDC Harsen Page 27/28

31 Troubleshooting 10. Troubleshooting Failure Controller abnormal Eliminating method Check controller s connection, if controller adopts AC power source, check A-ph voltage and the related fuse (switch) of dual power, if controller adopts DC power source, both check the supply status and fuse of DC power source. The data displayed is not accurate Check the measured circuitry is well connected or not, the grounding wire is well contacted or not. The transfer switch fails to transfer Check the connection of the control circuit to find out if the three phase voltage is set at the range of high/low voltage and high/low frequency; check the related relay output is normal action or not; check the fuse of closing power source. The transfer switch is normal transfer, but controller cannot display close. Check the connection of the control circuit, check the aux contact of transfer switch close and the related circuit connection Can not MAN transfer under MAN mode Check the connection of the control circuit, and check the fuse of closing power source. Harsen Page 28/28

32 Service Hotline More technical support, Please browse our website:

HAT270A ATS (Automatic Transfer Switch) CONTROLLER OPERATING MANUAL Smartgen Electronics

HAT270A ATS (Automatic Transfer Switch) CONTROLLER OPERATING MANUAL Smartgen Electronics HAT270A ATS (Automatic Transfer Switch) CONTROLLER OPERATING MANUAL Smartgen Electronics CONTENT 1 SUMMARY... 4 2 FEATURES... 4 3 SPECIFICATION... 5 4 PANEL OPERATING INSTRUCTION... 6 5 PANEL OPERATION

More information

HAT162 ATS CONTROLLER USER MANUAL

HAT162 ATS CONTROLLER USER MANUAL HAT162 ATS CONTROLLER USER MANUAL SMARTGEN (ZHENGZHOU) TECHNOLOGY CO.,LTD. Chinese trademark English trademark SmartGen make your generator smart SmartGen Technology Co., Ltd. No. 28 Jinsuo Road Zhengzhou

More information

HAT600 Series HAT600/HAT600I/HAT600B/HAT600BI ATS CONTROLLER USER MANUAL

HAT600 Series HAT600/HAT600I/HAT600B/HAT600BI ATS CONTROLLER USER MANUAL HAT600 Series HAT600/HAT600I/HAT600B/HAT600BI ATS CONTROLLER USER MANUAL ZHENGZHOU SMARTGEN TECHNOLOGY CO.,LTD CONTENT 1 OVERVIEW... 5 2 PERFORMANCE AND CHARACTERISTICS... 6 3 SPECIFICATION... 8 4 OPERATING...

More information

HAT560NC SERIES (HAT560NC /HAT560NBC) ATS CONTROLLER USER MANUAL

HAT560NC SERIES (HAT560NC /HAT560NBC) ATS CONTROLLER USER MANUAL HAT560NC SERIES (HAT560NC /HAT560NBC) ATS CONTROLLER USER MANUAL SMARTGEN (ZHENGZHOU) TECHNOLOGY CO., LTD. Chinese trademark English trademark SmartGen make your generator smart SmartGen Technology Co.,

More information

ATS CONTROLLER OPERATING MANUAL

ATS CONTROLLER OPERATING MANUAL HAT600 Series HAT600/HAT600I/HAT600B/HAT600BI ATS CONTROLLER OPERATING MANUAL Smartgen Electronic CONTENT 1 SUMMARY... 4 2 PERFORMANCE AND CHARACTERISTICS... 4 3 SPECIFICATION... 5 4 OPERATING... 6 4.1

More information

HAT530 ATS CONTROLLER USER MANUAL

HAT530 ATS CONTROLLER USER MANUAL HAT530 ATS CONTROLLER USER MANUAL Software Version Version Date Note 1.0 2014-06-23 Original release. Clarification of notation used within this publication. SIGN INSTRUCTION NOTE Highlights an essential

More information

HGM9580 Bus Tie Bus Parallel Unit USER MANUAL. Smartgen Technology

HGM9580 Bus Tie Bus Parallel Unit USER MANUAL. Smartgen Technology HGM9580 Bus Tie Bus Parallel Unit USER MANUAL Smartgen Technology This manual is suitable for HGM9580 bus tie bus parallel unit only. Clarification of notation used within this publication. SIGN INSTRUCTION

More information

HAT160 ATS CONTROLLER USER MANUAL

HAT160 ATS CONTROLLER USER MANUAL HAT160 ATS CONTROLLER USER MANUAL SMARTGEN (ZHENGZHOU) TECHNOLOGY CO.,LTD. Chinese trademark English trademark SmartGen make your generator smart SmartGen Technology Co., Ltd No. 28 Jinsuo Road Zhengzhou

More information

2 Table of Contents 1. TABLE OF CONTENTS. 1. Table of Contents Introduction Wiring Diagram Terminals Review...

2 Table of Contents 1. TABLE OF CONTENTS. 1. Table of Contents Introduction Wiring Diagram Terminals Review... TPR-6 Temperature Protection Relay Instruction Manual Ver. June 1 st 2010 2 Table of Contents 1. TABLE OF CONTENTS 1. Table of Contents... 2 2. Introduction... 3 3. Wiring Diagram... 5 4. Terminals Review...

More information

DGC-2000 DIGITAL GENSET CONTROLLER

DGC-2000 DIGITAL GENSET CONTROLLER DGC-2000 DIGITAL GENSET CONTROLLER Basler Electric s Digital Genset Controller (DGC-2000) offers an integrated alternative for genset control and monitoring. Control includes engine starting and shutdown

More information

Standard Options. Model 4100 Position Indicating Meter. Three Phase Motor Control. Positran Transmitter

Standard Options. Model 4100 Position Indicating Meter. Three Phase Motor Control. Positran Transmitter Standard Options Model 4100 Position Indicating Meter A percent-of-full-travel meter is supplied with a trim potentiometer resistor, terminal block and connectors. A potentiometer is required in the actuator

More information

Quantum III. Compact DC Drive Package. Slitter DC Drive Package. Quantum III

Quantum III. Compact DC Drive Package. Slitter DC Drive Package. Quantum III Compact DC Drive Package The delivers a DC drive package that integrates the intelligence of the Mentor II with a space saving design that incorporates many accessories typically required in the North

More information

HAT72 ATS CONTROLLER USER MANUAL

HAT72 ATS CONTROLLER USER MANUAL HAT72 ATS CONTROLLER USER MANUAL Software Version Version Date Note 1.0 2007-12-01 Original release. 1.1 2015-03-11 Modify some details. 1.2 2015-04-21 Modify some details. Clarification of notation used

More information

PFC-10 Power Factor Controller

PFC-10 Power Factor Controller PFC-10 Power Factor Controller Instruction Manual Ver. 6.0 / 2002 (2-2005 update) Table of Contents Page Subject 3 Starter ion 4-5 Installation Notes 6-7 Terminals Review & Control Wiring 8 Front-panel

More information

[ ACD-S ] User s Manual. O-Sung Electric Machinery Co., Ltd. 136, Hataemal-gil, Wollong-Myeon Paju-si, Gyeonggi-do, Korea

[ ACD-S ] User s Manual. O-Sung Electric Machinery Co., Ltd. 136, Hataemal-gil, Wollong-Myeon Paju-si, Gyeonggi-do, Korea [ ACD-S ] User s Manual O-Sung Electric Machinery Co., Ltd. 136, Hataemal-gil, Wollong-Myeon Paju-si, Gyeonggi-do, Korea Tel : (031) 944-3521 / Fax : (031) 944-3525 http://www.osemco.com / ousung@chol.com

More information

High Voltage DC Meter

High Voltage DC Meter High Voltage DC Meter Javelin D PD644 0-300 VDC input NEMA 4X, IP65 front Scale in engineering units Sunlight readable LED display 4-20 ma analog output Two form C 3 A relays option RS-485 serial communications

More information

HIGH-VOLTAGE DC METER

HIGH-VOLTAGE DC METER HIGH-VOLTAGE DC METER Javelin D PD644 0-300 VDC input NEMA 4X, IP65 front Scale in engineering units Sunlight readable LED display 4-20 ma analog output Two form C 3 A relays option RS-485 serial communications

More information

Digital Speed Controller User Manual

Digital Speed Controller User Manual Diesel Engine for Generators Digital Speed Controller User Manual (DSC-1000) Ver_1.0 Doosan Infracore 페이지 1 / 36 Contents 1. Product Overview and General Specification 1.1 Product Information 1.2 Product

More information

[ ACD-NA ] User s Manual. O-Sung Electric Machinery Co., Ltd. 136, Hataemal-gil, Wollong-Myeon Paju-si, Gyeonggi-do, Korea

[ ACD-NA ] User s Manual. O-Sung Electric Machinery Co., Ltd. 136, Hataemal-gil, Wollong-Myeon Paju-si, Gyeonggi-do, Korea [ ACD-NA ] User s Manual O-Sung Electric Machinery Co., Ltd. 136, Hataemal-gil, Wollong-Myeon Paju-si, Gyeonggi-do, Korea Tel : (031) 944-3521 / Fax : (031) 944-3525 http://www.osemco.com / ousung@chol.com

More information

HAT260 ATS (Automatic Transfer Switch) Controller USER MANUAL. Smartgen Technology

HAT260 ATS (Automatic Transfer Switch) Controller USER MANUAL. Smartgen Technology HAT260 ATS (Automatic Transfer Switch) Controller USER MANUAL Smartgen Technology Chinese trademark English trademark Smartgen make your generator smart Smartgen Technology Co., Ltd No. 28 Jinsuo Road

More information

Voltage Transducer UMT516 / MT516

Voltage Transducer UMT516 / MT516 Voltage Transducer UMT516 / MT516 True RMS AC voltage measurements Voltage auto range measurements up to 600V # Wide frequency measurement range 16 400 Hz High accuracy class 0.2 (IEC-688), 0.1 on communication

More information

Features. Line Regulation. Load Regulation. Safety. Cooling. Input Connectors. Output Connectors. Overvoltage Protection. Over Temperature Protection

Features. Line Regulation. Load Regulation. Safety. Cooling. Input Connectors. Output Connectors. Overvoltage Protection. Over Temperature Protection Specifications: Input Voltage ( 3 phase ) No of Phases Input Frequency 208VAC ( 170 ~ 265 ) Code: 3P208 415VAC ( 342 ~ 460 ) Code: 3P400 Wye or Delta, 4 wire 3phase and one protective earth. 47 ~ 63Hz

More information

SDM-6RO. Expansion Module 6 relay outputs. Manufactured for

SDM-6RO. Expansion Module 6 relay outputs. Manufactured for Version 1.0 5.02.2014 Manufactured for Thank you for choosing our product. This manual will help you with proper support and proper operation of the device. The information contained in this manual have

More information

QUALITY POWER SOLUTIONS BACKED UP BY REAL-WORLD ENGINEERING EXPERIENCE

QUALITY POWER SOLUTIONS BACKED UP BY REAL-WORLD ENGINEERING EXPERIENCE QUALITY POWER SOLUTIONS BACKED UP BY REAL-WORLD ENGINEERING EXPERIENCE User s Manual SR250HL Power Supply/ Float Charger for Lead Acid Batteries STANDARD FEATURES OPTIONAL FEATURES 3 Relay Alarms-Form

More information

ATS CONTROLLER [ ACD-III ], [ ACD-III-C ] User s Manual. O-Sung Electric Machinery Co., Ltd.

ATS CONTROLLER [ ACD-III ], [ ACD-III-C ] User s Manual. O-Sung Electric Machinery Co., Ltd. ATS CONTROLLER [ ACD-III ], [ ACD-III-C ] User s Manual O-Sung Electric Machinery Co., Ltd. 136, Hataemal-gil, Wollong-Myeon Paju-si, Gyeonggi-do, Korea Tel : (031) 944-3521 / Fax : (031) 944-3525 http://www.osemco.com

More information

Simplified information where and how you want it.

Simplified information where and how you want it. ConsolIdator 4 & 8 Multi-channel controllers Simplified information where and how you want it. ConsoliDator 4 Model PD940 ConsoliDator ConsoliDator 4 Features Four 4-20 Inputs Four 4-20 Outputs ConsoliDator

More information

WSK INTELLIGENT TEMPERATURE AND HUMIDITY CONTROLLER USER MANUAL

WSK INTELLIGENT TEMPERATURE AND HUMIDITY CONTROLLER USER MANUAL WSK INTELLIGENT TEMPERATURE AND HUMIDITY CONTROLLER USER MANUAL WSK INTELLIGENT TEMPERATURE AND HUMIDITY CONTROLLER USER MANUAL v 1.0 Thanks for choosing the Intelligent temperature and humidity controller

More information

100% electricity. Automatic transfer switch controllers ATL series

100% electricity. Automatic transfer switch controllers ATL series 100% electricity Automatic transfer switch controllers ATL series Automatic transfer switch controllers Keep control around the clock General characteristics Rated auxiliary power supply: 220-230-240VAC

More information

S66 Series Electronic Fan Speed Control

S66 Series Electronic Fan Speed Control FANs 121, 125, 1628.3 Product/Technical Bulletin S66 Issue Date 0918 S66 Series Electronic Fan Speed Control The S66 Series Electronic Fan Speed Control is designed to modulate the speed of single-phase,

More information

HydroGuard 4 to 20 ma Output Module. For use with HydroGuard Water Quality Monitor and Controller

HydroGuard 4 to 20 ma Output Module. For use with HydroGuard Water Quality Monitor and Controller HydroGuard 4 to 20 ma Output Module For use with HydroGuard Water Quality Monitor and Controller Technician's Manual Installation, Operation, and Maintenance Guide Chapter 1: Preface... 3 1.1 Intended

More information

Multifunction Transducer MT440

Multifunction Transducer MT440 Multifunction Transducer MT440 Voltage and current auto range measurements up to 600V, 12.5A Universal wide auxiliary power supply range 24 300 Vdc, 40 276 Vac Power accuracy class 0.5 (EN 60 688), Up

More information

2 in 1 LAN Tester and Multimeter Model:

2 in 1 LAN Tester and Multimeter Model: 2 in 1 LAN Tester and Multimeter Model: 72-8495 1 IMPORTANT SAFETY INFORMATION Please read these instructions carefully before use and retain for future reference. This instrument is designed and manufactured

More information

Features. Conducted Emission. Radiated Emission. Line Regulation. Load Regulation. Safety. Cooling. Input Connectors.

Features. Conducted Emission. Radiated Emission. Line Regulation. Load Regulation. Safety. Cooling. Input Connectors. Specifications: Input Voltage ( 1 phase ) ( 3 phase ) No of Phases Input Frequency 230VAC ( 170 ~ 265 ) Code: 1P200 208VAC ( 170 ~ 265 ) Code: 3P208 415VAC ( 342 ~ 460 ) Code: 3P400 1phase or 3phase Wye

More information

2.) Cabinet setup and preset data shall, as standard, be fully user programmable on a per cabinet or system wide basis.

2.) Cabinet setup and preset data shall, as standard, be fully user programmable on a per cabinet or system wide basis. A21 DIMMER CABINET SPECIFICATION. GENERAL. A.) Overview. 1.) The dimmer cabinets shall be fully digital, designed specifically for architectural and entertainment lighting applications, and shall consist

More information

PLT. Breaker-based transfer switch open, closed or soft transition amps. Specification sheet

PLT. Breaker-based transfer switch open, closed or soft transition amps. Specification sheet Specification sheet PLT Breaker-based transfer switch open, closed or soft transition 800 3000 amps Description PLT breaker-based transfer switches are designed for operation and switching of electrical

More information

INSTALLATION DKM-409 NETWORK ANALYSER WITH HARMONIC MEASUREMENT AND SCOPEMETER. Before installation:

INSTALLATION DKM-409 NETWORK ANALYSER WITH HARMONIC MEASUREMENT AND SCOPEMETER. Before installation: DKM-409 NETWORK ANALYSER WITH HARMONIC MEASUREMENT AND SCOPEMETER The DKM-409 is a precision instrument designed for displaying various AC parameters in 3-phase distribution panels. Thanks to its isolated

More information

Features. Conducted. Emission. Line Regulation. Load Regulation. Safety. Cooling. Input Connectors. Overvoltage Protection. Phase Loss.

Features. Conducted. Emission. Line Regulation. Load Regulation. Safety. Cooling. Input Connectors. Overvoltage Protection. Phase Loss. Features Specifications: High Power Density 3.3KW in 2U 1 phase 240vac input 3 phase input 208VAC / 415VAC options Power Factor Correction Output voltage up to 600V, current up to 400A Built-in RS232 /

More information

Product Sheet ECO. Types ECG, AMF Technical data. product sheet eco ecg-amf - technical data gb v1.0.docx

Product Sheet ECO. Types ECG, AMF Technical data.  product sheet eco ecg-amf - technical data gb v1.0.docx ECO Types ECG, AMF Technical data Product overview ECO ECG and ECO AMF are microprocessor controlled devices for use in low voltage single genset applications for standby power generation. The front-side

More information

Mounting and Connections

Mounting and Connections Receipt of the GPU-2000R When you receive the GPU-2000R, examine it carefully for shipping damage. If any damage or loss is evident, file a claim at once with the shipping agent and promptly notify the

More information

POE084824B. PoE 54V/8x0,3A/4x7Ah PoE buffer power supply for up to 8 IP camera. v.1.1 EN* Edition: 7 from

POE084824B. PoE 54V/8x0,3A/4x7Ah PoE buffer power supply for up to 8 IP camera. v.1.1 EN* Edition: 7 from POE084824B v.1.1 PoE 54V/8x0,3A/4x7Ah PoE buffer power supply for up to 8 IP camera. EN* Edition: 7 from 15.11.2017 Supersedes the edition: 6 from 22.11.2016 GREEN POWER CCTV PoE PSU features: DC 54V uninterruptible

More information

EM132 EM132. Main Features. Multi-functional 3-Phase Transducer. Energy Meter

EM132 EM132. Main Features. Multi-functional 3-Phase Transducer. Energy Meter EM132 MULTI-FUNCTION TRANSDUCER SATEC EM132 is a Smart DIN Rail Multi-Function Transducer with a local display. It is based on SATEC s best seller PM130 PLUS with an off-the-shelf LCD display (similar

More information

www. ElectricalPartManuals. com .Basler Electric BE1-878 HIGH IMPEDANCE BUS DIFFERENTIAL RELAY ADVANTAGES ADDITIONAL INFORMATION APPLICATION Page2

www. ElectricalPartManuals. com .Basler Electric BE1-878 HIGH IMPEDANCE BUS DIFFERENTIAL RELAY ADVANTAGES ADDITIONAL INFORMATION APPLICATION Page2 The Bus Differential Relay provides economical high speed protection in a conventional package for all high impedance differential applications. ADVANTAGES Proven performance of High Impedance Differential

More information

EC700. Pulses concentrator. User instructions

EC700. Pulses concentrator. User instructions EC700 Pulses concentrator User instructions Contents Hazards and warning... 3 Initial checks... 3 Introduction... 4 Jbus/Modbus Communication... 5 Installation... 6 Configuration... 9 Use... 9 Programming...

More information

Batch Controller with numerical keypad, remote control inputs and 3 control / alarm / pulse outputs

Batch Controller with numerical keypad, remote control inputs and 3 control / alarm / pulse outputs Datasheet N410 User-friendly batch controller Reliable Batch Controller with numerical keypad, remote control inputs and 3 control / alarm / pulse outputs Advantages Save time and cost with the easy to

More information

SDM-8AO. Expansion Module 8 analog outputs. Manufactured for

SDM-8AO. Expansion Module 8 analog outputs. Manufactured for Version 1.0 16.05.2014 Manufactured for Thank you for choosing our product. This manual will help you with proper support and proper operation of the device. The information contained in this manual have

More information

Genset Controller Unit Model EMS - GC10. Installation Manual Section

Genset Controller Unit Model EMS - GC10. Installation Manual Section Genset Controller Unit Model EMS - GC10 Installation Manual 00-02-0794 Section 75 2013-01-28 In order to consistently bring you the highest quality, full featured products, we reserve the right to change

More information

DATA CONNECT ENTERPRISE

DATA CONNECT ENTERPRISE DATA CONNECT ENTERPRISE User s Manual IG202T and IGV23 Modem Document Number 520-01005-001 Rev. A DATA CONNECT Contents Contents... iii Figures... iv Chapter 1 Introduction... 5 Features...6 Applications...7

More information

Flomatic Smart Card TM Model FDHC-100 (Digital High-Resolution Controller) Configuration and Operation Manual

Flomatic Smart Card TM Model FDHC-100 (Digital High-Resolution Controller) Configuration and Operation Manual The Flomatic FDHC-100 is a high performance Digital positioner intended to control AC actuators, providing 450 points of resolution with quarter turn actuators ranging from 2 sec to 120 sec and rated for

More information

INSTRUCTION SHEET. Eaton Logic Controller ELCB Controllers

INSTRUCTION SHEET. Eaton Logic Controller ELCB Controllers 2010-12-10 5011699201-PBB1 Eaton Logic Controller ELCB Controllers INSTRUCTION SHEET [Applicable Controllers] ELCB-PB10 ELCB-PB14 ELCB-PB20 ELCB-PB30 ELCB-PB40 IL05001005E 002-1310020-02 Thank you for

More information

GRID-TIED SOLAR INVERTER 1.5KW ~ 6.0KW V.1.2

GRID-TIED SOLAR INVERTER 1.5KW ~ 6.0KW V.1.2 USER MANUAL MPI-1500/2000/3000/4000/6000 Series GRID-TIED SOLAR INVERTER 1.5KW ~ 6.0KW V.1.2 WWW.MPPSOLAR.COM WARNING: ONLY A CERTIFIED ELECTRICIAN OR TRAINED ASSEMBLING PROFESSIONAL SHOULD OPEN OR INSTALL

More information

PM174 PM174 IEEE1159 ADVANCED POWER QUALITY ANALYZER. Features

PM174 PM174 IEEE1159 ADVANCED POWER QUALITY ANALYZER. Features PM174 IEEE1159 ADVANCED POWER QUALITY ANALYZER The PM174 is a compact, multi-function, three-phase AC powermeter and power quality analyzer specially designed to meet the requirements of users ranging

More information

DIRIS Digiware D and C Communication and control power interfaces

DIRIS Digiware D and C Communication and control power interfaces Multi-circuit metering and measurement diris-dw_006_a_us_cat diris-dw_142_a The solution for > Industry > Building > Infrastructure > Data centers DIRIS D-40/D-50/D-70 Centralization and display of data

More information

Iso DIN. User Manual. 1 channel Earth Fault Monitoring

Iso DIN. User Manual. 1 channel Earth Fault Monitoring Page 1 of 5 2017 03 20 User Manual Iso DIN Iso DIN User Manual 1 channel Earth Fault Monitoring Megacon AB Ranhammarsvägen 20 S 168 67 Bromma Sweden Tel: 08 402 42 50 sales@megacon.se www.megacon.se eee

More information

Power 004=0.4kW 015=1.5kW. Delta Variable Frequency Drive

Power 004=0.4kW 015=1.5kW. Delta Variable Frequency Drive Type number key VFD 007 L 21 A Version number A= filter, NPN inputs B=Built-in filter, NPN inputs D= filter, PNP inputs E=Built-in filter, PNP inputs Input voltage 11=115VAC 21=230VAC 1φ 23=230VAC 3φ VFD-L

More information

INSTALLATION MANUAL. LC 200 Electronic Overload Guard. Software versione PW0501 R 0.3

INSTALLATION MANUAL. LC 200 Electronic Overload Guard. Software versione PW0501 R 0.3 INSTALLATION MANUAL LC 200 Electronic Overload Guard Software versione PW0501 R 0.3 CONTENTS MAIN FEATURES LC 200 TECHNICAL FEATURES Page 2 SYMBOLS Page 3 WARNINGS Page 3 IDENTIFICATION DATA PLATE Page

More information

SERIES 230 Automatic Transfer Switch C1000 Intelligent Controller User Manual

SERIES 230 Automatic Transfer Switch C1000 Intelligent Controller User Manual SERIES 230 Automatic Transfer Switch C1000 Intelligent Controller User Manual Document Version V2.3 Archive Date Jan 12 th, 2018 BOM Code 31012665 ASCO Power Technologies provides customers with technical

More information

GCI-5K INSTALLATION AND OPERATOR S MANUAL

GCI-5K INSTALLATION AND OPERATOR S MANUAL GCI-5K INSTALLATION AND OPERATOR S MANUAL Grid-tied inverter for wind Ningbo Ginlong Technologies 1 INTRODUCTION 2 SAFETY GUIDELINES AND WARNINGS 3 INSTALLATION 3.1 Selecting a location for the inverter

More information

CMM366-3G CLOUD MONITORING COMMUNICATION MODULE USER MANUAL

CMM366-3G CLOUD MONITORING COMMUNICATION MODULE USER MANUAL CMM366-3G CLOUD MONITORING COMMUNICATION MODULE USER MANUAL SMARTGEN (ZHENGZHOU) TECHNOLOGY CO., LTD. Chinese trademark English trademark SmartGen make your generator smart SmartGen Technology Co., Ltd.

More information

LAUREL. Laureate Digital Panel Meter for Load Cell & Microvolt Input ELECTRONICS, INC. Features. Description

LAUREL. Laureate Digital Panel Meter for Load Cell & Microvolt Input ELECTRONICS, INC. Features. Description Description LAUREL ELECTRONICS, INC. Features Laureate Digital Panel Meter for Load Cell & Microvolt Input 20, 50, 100, 250 & 500 mv ranges Span adjust from 0 to ±99,999, zero adjust from -99,999 to +99,999

More information

Typical Input current at 1.15A 0.65A 60 Watt 24VDC / 2.5A. 1.84A 1.0A 120 Watt 24VDC / 5.0A

Typical Input current at  1.15A 0.65A 60 Watt 24VDC / 2.5A. 1.84A 1.0A 120 Watt 24VDC / 5.0A SmartPower TM The Autotech SmartPower is a DC switching power supply with 24V output Voltage. This user friendly power supply has two 7-segment LED displays for voltage and current monitoring. This DC

More information

Dupline. Data Logger. Types G , G Product Description. Ordering Key G Type Selection. Input/Output Specifications

Dupline. Data Logger. Types G , G Product Description. Ordering Key G Type Selection. Input/Output Specifications Dupline Data Logger Types G 800 006, G 800 106 Product Description Programmable channel generator with optional built-in GSM Modem Event and time based data logging functions for digital, analog and counter

More information

EnCell Battery Cell Monitor

EnCell Battery Cell Monitor EnCell Battery Cell Monitor Instruction Manual Model RCM15S12 NERC Compliant YO R U H T PA TO Z O R E W O D N M I T E enchargepowersystems.com sales@enchargepowersystems.com (888) 407.5040 Contents 1 Warnings,

More information

GE Power Management. MMII Intelligent MCC Controller

GE Power Management. MMII Intelligent MCC Controller A concept that will offer reduced overall installed cost and production efficiency through information availability to operators and maintenance. Presentation Overview 6 Applications 6 Protection and Control

More information

DTS 310. DIN Rail Mounted, Indoor Rated Revenue Grade Electrical Sub-meter. Page 1. Measurlogic MQ A

DTS 310. DIN Rail Mounted, Indoor Rated Revenue Grade Electrical Sub-meter. Page 1. Measurlogic MQ A DTS 310 DIN Rail Mounted, Indoor Rated Revenue Grade Electrical Sub-meter Page 1 1 PRODUCT OVERVIEW... 3 1.1 SUPPLIED ITEMS... 3 1.2 DOCUMENT CONVENTIONS... 4 1.3 PRODUCT SPECIFICATION... 4 1.3.1 Current

More information

TC-9102 Series Surface Mount Temperature Controllers

TC-9102 Series Surface Mount Temperature Controllers TC-9102 Series Surface Mount Temperature Controllers General Description & Applications The TC-9102 Series Temperature Controller offers a versatile solution for a wide variety of applications that may

More information

MPCR Series DeviceNet Technical Manual TDMPCRDNTM2-0EN 01/08 Subject to change without notice

MPCR Series DeviceNet Technical Manual TDMPCRDNTM2-0EN 01/08 Subject to change without notice MPCR Series DeviceNet Technical Manual Table of Contents MPCR Series Introduction... 3 Product Overview... 3 About DeviceNet... 4 Overview... 4 MPCR DeviceNet Features... 4 Cabling and Drop Line Lengths

More information

MICROFUSION FEATURES OPTIONS CERTIFICATIONS (PENDING) THREE PHASE SCR POWER CONTROLLERS

MICROFUSION FEATURES OPTIONS CERTIFICATIONS (PENDING) THREE PHASE SCR POWER CONTROLLERS MICROFUSION THREE PHASE SCR POWER CONTROLLERS FEATURES Auto-Ranging Input Voltage 24-600 VAC, 45-65 Hz AC Output 16, 32, 50, 80 Amps (@ 50 C 6000 ft) Control Features Microprocessor-based controller /

More information

RS485 MODBUS Module 6RO

RS485 MODBUS Module 6RO Version 2.0 12/02/2013 Manufactured for Thank you for choosing our product. This manual will help you with proper support and proper operation of the device. The information contained in this manual have

More information

SCP-C Instruction and Commissioning Manual

SCP-C Instruction and Commissioning Manual SCP-C Cathodic Protection Controller 8-150A, 50V Instruction Manual Ver. 20/12/2009 2 Table of Contents SCP-C Instruction and Commissioning Manual Table of Contents 1. List of Figures...3 2. Safety & Warnings...4

More information

Overview. Features CHAPTER

Overview. Features CHAPTER CHAPTER 2 This chapter provides these topics that describe the Catalyst 2955 switch, hereafter referred to as the switch. Features, page 2-1 Front-Panel Description, page 2-3 Rear-Panel Description, page

More information

12-36 VDC/12-24 VAC Power Option 4-Digit Display, 0.56 (14.2 mm) or 1.20 (30.5 mm)

12-36 VDC/12-24 VAC Power Option 4-Digit Display, 0.56 (14.2 mm) or 1.20 (30.5 mm) 4-20 ma & Relay Output Features 4-20 ma, ± 10 V, TC & RTD Inputs 12-36 VDC/12-24 VAC Power Option 4-Digit Display, 0.56 (14.2 mm) or 1.20 (30.5 mm) 24 VDC @ 200 ma Transmitter Power Supply Options Type

More information

SORDS ELECTRIC ~ MA7200. Sensorless Vector AC Inverter.

SORDS ELECTRIC ~ MA7200. Sensorless Vector AC Inverter. www.sordselectric.com MA7200 Sensorless Vector AC Inverter Features and Benefits Sensorless Vector The MA7200 has precise speed and torque control for the most demanding system performance and simple set-up

More information

Instruction Manual. 2in1 LAN Tester & Multimeter. Model: 57314

Instruction Manual. 2in1 LAN Tester & Multimeter. Model: 57314 Instruction Manual 2in1 LAN Tester & Multimeter Model: 57314 1 Contents Introduction... Features... Safety Precautions.. Meter Description... Electrical Specification... Operation.. AutoRanging Multimeter.

More information

Operating Instructions. For. Level Control Module. Model SSR 1000

Operating Instructions. For. Level Control Module. Model SSR 1000 Operating Instructions For Level Control Module Model SSR 1000 SSR Operation Instructions Rev. 1 Jan 01 Page 1/7 1. Note Please read and take note of these operating instructions before unpacking and commissioning.

More information

Quick Start Guide TS A

Quick Start Guide TS A Quick Start Guide TS 930 125-630A DANGER HAZARD OF ELECTRICAL SHOCK, EXPLOSION, OR ARC FLASH Read and understand this quick start guide before installing and operating the transfer switch The installer

More information

M15S OPERATION MANUAL

M15S OPERATION MANUAL M15S OPERATION MANUAL minikol ITALY www.minikol.com Index 1. Operation overview and general introduction... 1 2. Operation Modes... 2 2.1. Manual mode...2 2.2. Single mode...3 2.2.1. Setting target value...3

More information

LE ELECTRONICS Pvt. Ltd.

LE ELECTRONICS Pvt. Ltd. LE ELECTRONICS Pvt. Ltd. Monitoring Relays: LVM Line Voltage Monitors LCM - Line Current Monitors VMR Voltage Monitoring Relays CMR Current Monitoring Relays VCMR Voltage Current Monitoring Relays LFM

More information

Series 230 Automatic Transfer Switch

Series 230 Automatic Transfer Switch Series 230 Automatic Transfer Switch The Recognized Leader in Power Transfer Switch Technology Offers the Most Advanced Transfer Switches in the World. Product Overview The Series 230 automatic transfer

More information

Suprex RS-485 SPX-7500 Wired Reader-Extender

Suprex RS-485 SPX-7500 Wired Reader-Extender Suprex RS-485 SPX-7500 Wired Reader-Extender Product Manual SPX-7500_MAN_181206 Cypress Integration Solutions 35 Years of Access Control Ingenuity CypressIntegration.com 2018 Cypress Computer Systems 1778

More information

MAXIMA+ Series Rotary Level Indicator

MAXIMA+ Series Rotary Level Indicator MAXIMA+ Series Rotary Level Indicator BinMaster: Division of Garner Industries 7201 N. 98th St., Lincoln, NE 68507 402-434-9102 email: info@binmaster.com www.binmaster.com OPERATING INSTRUCTIONS PLEASE

More information

Switched Mode Power Supply Operating manual PAP800

Switched Mode Power Supply Operating manual PAP800 Features: Switched mode power supply Wide output 0 144Vdc Analog control by an external 0 5Vdc Power failure alarm output Master-slave connection Powerfinn PAP series is a high power, lightweight, advanced

More information

SATEL I-LINK 100 MB I/O-converter User Guide, Version 1.1

SATEL I-LINK 100 MB I/O-converter User Guide, Version 1.1 TABLE OF CONTENTS TABLE OF CONTENTS... 1 IMPORTANT NOTICE... 2 PRODUCT CONFORMITY... 3 WARRANTY AND SAFETY INSTRUCTIONS... 4 1 GENERAL... 5 1.1 SATEL I-LINK 100 MODBUS I/O- CONVERTER... 5 2 SPECIFICATIONS...

More information

LAUREL. Laureate Pulse or Analog Input Batch Controller Automatic batch control for repetitive liquid fill operations ELECTRONICS, INC.

LAUREL. Laureate Pulse or Analog Input Batch Controller Automatic batch control for repetitive liquid fill operations ELECTRONICS, INC. Description LAUREL ELECTRONICS, INC. Laureate Pulse or Analog Input Batch Controller Automatic batch control for repetitive liquid fill operations Features Available for turbine flow meter pulse signals

More information

OVEN INDUSTRIES, INC.

OVEN INDUSTRIES, INC. OVEN INDUSTRIES, INC. OPERATING MANUAL MODEL 5C7-195 THERMOELECTRIC MODULE TEMPERATURE CONTROLLER TABLE OF CONTENTS Page Features...1 Description...2 Block Diagram...2 Mechanical Package Drawing...3 RS232

More information

ATS-16 HV USER MANUAL. Automatic Transfer Switch 16A / 230Vac V090318

ATS-16 HV USER MANUAL. Automatic Transfer Switch 16A / 230Vac V090318 ATS-16 HV Automatic Transfer Switch 16A / 230Vac USER MANUAL V090318 SAFETY Intended use The ATS-16 HV device serves as a power source selector to provide improved power supply for connected loads. ATS-16

More information

Security Management System by Diebold, Inc. LINX System Hardware Installation Guide

Security Management System by Diebold, Inc. LINX System Hardware Installation Guide Security Management System by Diebold, Inc. LINX System Hardware Installation Guide INSTALLATION GUIDE LINX Integrated Security System WSD 2000 Weatherized Status Display Table of Contents Introduction

More information

1/32-DIN TEMPERATURE CONTROLLER INSTALLATION, WIRING AND OPERATION MANUAL FORM 3882

1/32-DIN TEMPERATURE CONTROLLER INSTALLATION, WIRING AND OPERATION MANUAL FORM 3882 1/32-DIN TEMPERATURE CONTROLLER INSTALLATION, WIRING AND OPERATION MANUAL FORM 3882 This manual is intended for use in support of installation, commissioning and configuration of the 1/32-DIN Temperature

More information

GV3000/SE Operator Interface Module (OIM) User Guide Version 2.0 M/N 2RK3000

GV3000/SE Operator Interface Module (OIM) User Guide Version 2.0 M/N 2RK3000 GV3000/SE Operator Interface Module (OIM) User Guide Version 2.0 M/N 2RK3000 Instruction Manual D2-3342-2 The information in this manual is subject to change without notice. Throughout this manual, the

More information

MIC-2 MKII, Multi-instrument DATA SHEET

MIC-2 MKII, Multi-instrument DATA SHEET MIC-2 MKII, Multi-instrument DATA SHEET Measurements All 3-phase AC measurements True RMS 4-Quadrant energy Power Quality Analysis Replaces analogue meters RS-485 Modbus RTU protocol TCP/IP Modbus (optional)

More information

OPERATIONAL MANUAL FOR 85XX

OPERATIONAL MANUAL FOR 85XX TECHNICAL DETAILS OPERATIONAL MANUAL FOR 85XX Ref. No. : m83/om/402 This is a versatile microcontroller based Scanner with a very high performance to price ratio. The features offered in this product are

More information

TFX PC Power Specifications

TFX PC Power Specifications TFX PC Power Specifications Model: HK340-71FP Consumer:Huntkey File NO: 试 产 Prepared by: Rex Checked by: Zhi Wu Approved by: Zhi Wu Issue date: 2010-03-29 REV:02 Model:HK340-71FP P/N:P15-3407100R Page

More information

Enercept H8035/H8036 Modbus Energy Meter Networked kw/kwh Transducers

Enercept H8035/H8036 Modbus Energy Meter Networked kw/kwh Transducers POWER MONITORING INSTALLATION GUIDE Enercept H8035/H8036 Modbus Energy Meter Networked kw/kwh Transducers US Patent No. 6,373,238 Installer's Specifications Input Voltage 208 to 480 VAC Number of Phases

More information

Buffered Power Supply PS-30DR v1.0

Buffered Power Supply PS-30DR v1.0 Roger Access Control System Buffered Power Supply PS-30DR v1.0 Document version: Rev. C Firmware: 1.0.4 1. PRODUCT DESCRIPTION The PS-30DR is dedicated for electronic equipment which require 12VDC buffered

More information

MX200 SERIES Modbus Card 50P GE Zenith Controls. Operation and Maintenance Manual 50R-2200B 12/00

MX200 SERIES Modbus Card 50P GE Zenith Controls. Operation and Maintenance Manual 50R-2200B 12/00 g MX200 SERIES Modbus Card 50P-1105 GE Zenith Controls 50R-2200B 12/00 Operation and Maintenance Manual Table of Contents Overview...01 Page LED Indicator...02 Installation...03 Installing the Network

More information

MAXIMA + Series ROTARY LEVEL CONTROL

MAXIMA + Series ROTARY LEVEL CONTROL Price $5.00 MAXIMA + Series ROTARY LEVEL CONTROL OPERATING INSTRUCTIONS PLEASE READ CAREFULLY Division of Garner Industries 7201 North 98th Street Lincoln, NE 68507-9741 (402) 434-9102 925-0268 Rev. A

More information

OPERATING INSTRUCTIONS 7 SERIES STATIC GENERATORS

OPERATING INSTRUCTIONS 7 SERIES STATIC GENERATORS OPERATING INSTRUCTIONS 7 SERIES STATIC GENERATORS GB Contents Page 1 Introduction 4 2 Safety 5 3 Use 6 4 Checking on Delivered Equipment 6 5 General Specification and Dimensions 7 6 Positioning 10 7 Operating

More information

Uninterruptible Power Supplies

Uninterruptible Power Supplies Xi Series 1-6kVA True On-Line UPS Features Rack-Mount/Standalone Format Universal Battery Design (Optional 10 year batteries) Dual Mains Input Dual Position Backlit LCD LCD Load Segment Control 2.5kVA

More information

Installation & Operation Guide

Installation & Operation Guide Installation & Operation Guide (Shown with optional Override Board Cover) KMD-5831 Programmable Loop Controller PLC-28 Direct Digital Controller 902-019-04B 1 Introduction This section provides a brief

More information

MAXIMA + Series ROTARY LEVEL CONTROL

MAXIMA + Series ROTARY LEVEL CONTROL Price $5.00 MAXIMA + Series ROTARY LEVEL CONTROL OPERATING INSTRUCTIONS PLEASE READ CAREFULLY Division of Garner Industries 7201 North 98th Street Lincoln, NE 68507-9741 (402) 434-9102 925-0268 TABLE OF

More information

Black Body Calibration Source User Manual

Black Body Calibration Source User Manual Black Body Calibration Source Surface Plate Type Models CBB13EC CBB14AC/KC CBB15GC CBB14AC CBB15GC CBB14KC Models: CBB13EC CBB14AC CBB14KC CBB15GC WD1068 October 18, 2013 Rev C 01/12/18 CBB13EC Wahl Instruments

More information