System-based switching, protecting, starting. SIRIUS Modular System. sirius
|
|
- Gervais Goodman
- 5 years ago
- Views:
Transcription
1 System-based switching, protecting, starting. Modular System. sirius
2 Everything for the electrical cabinet: Modular System. Contents S00 structure S00 selection and ordering data: Circuit breakers, contactors, soft starters, overload relays Press Shop Master control room S0 structure S0 selection and ordering data: Circuit breakers, contactors, soft starters, overload relays S structure S selection and ordering data: Circuit breakers, contactors, soft starters, overload relays S structure Power distribution Body Shop Paint Shop Final Assembly Powertrain/ Assembly S selection and ordering data: Circuit breakers, contactors, soft starters, overload relays S, S0, S structure S, S0, S selection and ordering data: Contactors, overload relays, soft starters Fuseless load feeders Infeed system Pressing, equipping, transporting. These functions run in many automated production environments. You ll find everything that you need to switch, protect and start motors with the extensive portfolio of the modular system. Everything. Quite simple. With. Reversing combinations up to kw Star-delta combinations up to kw Safety-related load feeders Accessories
3 Everything. System-based. Modular System. When configuring electrical cabinets everything must proceed quickly, simply, flexibly using minimum space. How can all of this be done? With our unique modular system. This offers you everything that you need to switch, protect and start motors and plants. This means a modular range of standard components up to 0 kw/00 V in just sizes. All of the components are optimally harmonized with one another and can be combined easily. They also use the same range of accessories. Industrial controls really can be this simple! Ongoing development and continuous innovation ensure that our customers today and tomorrow are best equipped with, and profit from costeffective solutions. All of the components of the modular system distinguish themselves due to their space-saving design and high degree of flexibility. Engineering, mounting & installation, wiring and maintenance can be simply implemented and in a time-saving fashion. It doesn t make any difference if you wish to configure your load feeders with circuit breakers or overload relays, contactors or soft starters always has the optimum product for your particular application. The advantages of the modular system at a glance Load feeders Modular design Versions and sizes Accessories Design Communication Service/maintenance Approvals Mounting Cage-Clamp terminals Service Environmental issues Design Up to 0 kw/00 V can be simply realized using standard device Everything fits together and can be combined as necessary Cost-effective and flexible with compact sizes Optimum degree of variance using standard accessories for all devices Fast commissioning, short equipping times, simple wiring Can be connected to AS-Interface and PROFIBUS DP Extremely long service life, reliable and low maintenance Approved and certified worldwide e.g. IEC, UL, CSA, CCC, marine engineering Screwed or snapped-on for permanent, safe and reliable mounting Fast, safe reliable connection, vibration-proof and maintenance-free Short delivery times include spare parts due to the global logistical network Environmentally-compatible production and materials, can be recycled, low power loss Clear, ergonomic and has received the if Product Design Award
4 An overview of the Modular System. Circuit breakers SENTRON VL Contactors Overload relays Soft starters S00 S0 S S S S0 S
5 Switching. Protecting. Starting. The components of the Modular System. Far more than ON/OFF: RV circuit breakers RV circuit breakers (MSP) are compact, current-limiting circuit breakers. They guarantee safe reliable shutdown when short circuits occur and protect loads and plants against overload. Furthermore, they are suitable for operationally switching load feeders with a low operating frequency and safely disconnecting the plant or system from the line supply when service is been carried out or changes are being made. SENTRON VL circuit breakers are suitable for applications above 00 A. As infeed and load feeder breaker, they protect plants and motors against short circuit and overload. Rugged and reliable: RT contactors Due to their extremely high ruggedness and optimum contact reliability, our contactors switch with supreme confidence. Furthermore, compact electrical cabinets can be configured with high packing densities. The reason for this is that the auxiliary switch blocks and solenoid protective circuitry are located within the envelope contours of the contactors. This makes it easier to expand the system and saves considerable space in the electrical cabinet. Tripping when things get tough: RU and RB overload relays The overload relays of the family, available as either thermal or electronic versions, protect loads connected to the main circuit, as a function of the current, and also protect other switching and protective devices in the particular load feeder. The electronic RB overload relays guarantee seamless motor and plant protection from 0. A to 0 A. Due to the wide setting ranges, the current range is covered with a minimum number of versions. Soft starting and stopping: RW soft starters RW soft starters offer a seamless range that covers all standard and high-feature motor starting applications. Today, it can be used in the widest range of applications to provide the advantages of soft starting and stopping and for simple, cost-effective implementation of machine concepts. Fast, reliable and user-friendly: spring-loaded technology You will have a completely new experience with state-of-the-art spring-loaded technology as it relates to simplicity and speed. These screwless terminals reduce connection times by up to %, and eliminate wiring mistakes. They can stand up to the toughest conditions due to the vibration and shockproof design. And they are virtually maintenance-free. It is no surprise that we are already using innovative spring-loaded technology for most of the modular system.
6 More about the Modular System. Straight ahead: The RA direct starter Phases interchanged: The RA reversing starter Two stages one start: The RA star-delta combination Ready for immediate use: Pre-wired load feeders Load feeders start loads using a combination of protective and switching functions. Generally, a multiple number of components is required to implement every type of starter. In order to reduce time and costs and especially to minimize downtimes we offer you a wide range of pre-wired starter solutions: Direct starters up to kw the optimum starter combination for all motors Reversing starters up to kw the matching combination for reversing motors Star-delta combinations up to kw the solution for running-up motors in stages Soft starters when soft starting and stopping is required Safe RA load feeders pre-mounted, wired and certified for the highest safety categories. Real stars that reduce time and wiring mistakes
7 User-friendly power infeed and distribution: infeed system The infeed system allows power to be fed in and distributed to a group of several circuit breakers or complete load feeders in a user-friendly fashion. These devices are available for power ratings up to. kw at 00 V AC within the modular system. For higher power ratings circuit breakers and load feeders, size S0 with screw terminals can be integrated into the system. The system can be expanded up to loads of kw. Additional //-pole components can be integrated next to the circuit breakers using a terminal block. At a glance: The highlights of the infeed system Can be configured and expanded in a modular fashion as required Maximum current capacity of 0 A Infeed, either from the right or left with max. mm for an increased degree of flexibility in the electrical cabinet Additional //-pole components can be integrated using a terminal block Simple plug-in connection system saves time when mounting and installing Space-saving configuration thanks to the extremely compact design Maintenance-free connection as a result of the high immunity to vibration More detailed information on the design of the infeed system is provided in the Chapter Infeed system.
8 S00 design Direct start Reversing start Assembly kit for busbar mounting 0 mm: RA9 -C 0 mm: RA9 -D comprising: wiring kit busbar adapter controlgear support link wedges Version Version Size S00 circuit breaker Size S00 circuit breaker Link module AC RA9 -AA00 Connector RA9 -AA00 Size S00 contactor, Size S00 contactors For busbar mounting (alternative) Busbar adapter 0 mm US0 -DM0 0 mm US -DM0 Wiring kit: RA9 -A upper link module, lower link module, connecting clips, mechanical interlock (these can be eliminated) For rail mounting (diagram) For busbar mounting (diagram) Directly snapped onto a mounting rail without adapter Controlgear support 0 mm US0 0-AM00 0 mm US 0-AM00 Busbar adapter 0 mm US0 -DM0 0 mm US -DM0 Link wedges ( = 00 wedges) US9 9-AA00 For rail mounting (alternative) Directly snapped onto mounting rails without adapter
9 S00 selection and ordering data -phase motor AC-/00 V [kw] Circuit breakers (MSP) Contactors Soft starters Overload relays Setting range CLASS RV0-0AA RV0-0BA RV0-0CA RV0-0DA RV0-0EA RV0-0FA RV0-0GA RV0-0HA0 0. RV0-0JA RV0-0KA0.. RV0 -AA0. RV0 -BA0.. RV0 -CA0.. RV0 -DA0. RV0 -EA0. RV0 -FA0.. RV0 -GA0. RV0 -HA0 0 RV0 -JA0 9 RV0 -KA0 Control Aux- supply iliary voltage switches AC 0 V, 0/0 Hz NC RT0 -AP0 NO RT0 -AP0 DC V NC RT0 -BB NO RT0 -BB AC 0 V, 0/0 Hz NC RT0 -AP0 NO RT0 -AP0 DC V NC RT0 -BB NO RT0 -BB AC 0 V, 0/0 Hz NC RT0 -AP0 NO RT0 -AP0 DC V NC RT0 -BB NO RT0 -BB Control supply voltage Rated operating current ) le AC/DC 0 0 V RW0 -CB AC/DC DC V RW0 -CB0 AC/DC 0 0 V 9 RW0 -CB AC/DC V 9 RW0 -CB0 Setting range CLASS 0 Thermal RU -0AB RU -0BB RU -0CB RU -0DB RU -0EB RU -0FB RU -0GB RU -0HB0 0. RU -0JB RU -0KB0.. RU -AB0. RU -BB0.. RU -CB0.. RU -DB0. RU -EB0. RU -FB0.. RU -GB0. RU -HB0 0 RU -JB0 9 RU -KB0 ) For rated device operating voltage Ve: 00 0 V (Ve: 0 V refer to Catalog) ) When using tripping class CLASS 0 refer to the information in the engineering support Engineering fuseless load feeders and also in the Catalog Setting range Electronic RB0 - RB0 0.. RB0 - NB0. RB0 - PB0 RB0 - SB0 Class 0 Class 0 ) S00
10 S0 design Direct start Reversing start Assembly kit for busbar mounting 0 mm: RA9 -C 0 mm: RA9 -D comprising: wiring kit busbar adapter controlgear support link wedges Assembly kit for rail mounting RA9 -B comprising: wiring kit rail adapter side modules link wedges Version Size S0 circuit breaker Version Size S0 circuit breaker Link module AC RA9 -AA00 DC RA9 -BA00 Size S0 contactor, Size S0 connectors Mechanical interlock RA9 -B Link module AC RA9 -AA00 DC RA9 -BA00 Wiring kit: RA9 -A upper link module, lower link module For busbar mounting (alternative) For busbar mounting (diagram) Busbar adapter 0 mm US0 -DM0 0 mm US -DM0 For rail mounting (diagram) Controlgear support 0 mm US0 0-AM00 0 mm US 0-AM00 Busbar adapter 0 mm US0 -DM0 0 mm US -DM0 Directly snapped onto a mounting rail without adapter Link wedges ( = 00 wedges) US9 9-AA00 For rail mounting (alternative) Rail adapter RA9 -AA00 Side module ( = 00 modules) RA9 0-B Link wedges ( = 00 wedges) US9 9-AA00
11 S0 selection and ordering data ) For rated device operating voltage Ve: 00 0 V (Ve: 0 V refer to Catalog) ) When using tripping class CLASS 0 refer to the information in the engineering support Engineering fuseless load feeders and also in the Catalog ) Fan available as accessory -phase motor AC-/00 V [kw].. Circuit breakers (MSP) Contactors Soft starters Overload relays Setting range CLASS 0 9. RV0 -KA0 Control Aux- supply iliary voltage contacts AC 0 V, 0/0 Hz RT0 -AL0 DC V RT0 -BB0 Control Rated- supply operating voltage current ) le AC/DC 0 0 V ). RW0 -AB Setting Thermal range CLASS 0 9. RU -KB0 Setting range Electronic.... RV0 -AA0 0 RV0 -BA0 AC 0 V, 0/0 Hz RT0 -AL0 DC V RT0 -BB0 AC/DC V ). RW0 -AB0 AC/DC 0 0 V ) RW0 -AB AC/DC V ) RW0 -AB0 RU -AB0 0 RU -BB0 RB0 - QB0 RV0 -CA0 AC 0 V, 0/0 Hz RT0 -AL0 DC V RT0 -BB0 AC/DC 0 0 V ) RW0 -AB RU -CB0 Class 0 Class 0 ) AC/DC V ) RW0 -AB0 0 RV0 -DA0 0 RU -DB0 S0
12 S design Direct start Reversing start gsße Hutschie adapter RA9 Leistungsschalter Baugröße S Assembly kit for busbar mounting 0 mm: RA9 -C 0 mm: RA9 -D comprising: wiring kit busbar adapter a 9 controlgear support side module 9 link wedges ungs- -AA00 Assembly kit for rail mounting -BA00 RA9 -B comprising: wiring kit e b Verdrahtungsbausatz RA9 -A a oberer Verdrahtungsbaustein b unterer Verdrahtungsbaustein rail adapter side modules link wedges Version Version Size S circuit breaker Size S circuit breaker Link module AC RA9 -AA00 DC RA9 -BA00 Size S contactor For busbar mounting (alternative) Busbar adapter 0 mm US0 -FP0 0 mm US -FP0, Size S connectors Mechanical interlock RA9 -B Link module AC RA9 -AA00 DC RA9 -BA00 Wiring kit: RA9 -A upper link module, lower link module For busbar mounting (diagram) For rail mounting (diagram) Rail adapter RA9 -AA00 Controlgear support 0 mm US0 0-AP00 0 mm US 0-AP00 Busbar adapter 0 mm US0 -FP0 0 mm US -FP0 Link wedges ( = 00 wedges) US9 9-AA00 9 Side module US9 9-MB00 For rail mounting (alternative) Rail adapter Link wedges ( = 00 wedges) RA9 -AA00 US9 9-AA00
13 S selection and ordering data ) For rated device operating voltage Ve: 00 0 V (Ve: 0 V refer to Catalog) ) When using tripping class CLASS 0 refer to the information in the engineering support Engineering fuseless load feeders and also in the Catalog ) Fan available as accessory -phase motor AC-/00 V [kw] Circuit breakers (MSP) Contactors Soft starters Overload relays Setting range CLASS 0 Control Aux- supply iliary voltage contacts Control Rated supply operating voltage current ) le Setting range CLASS 0 Thermal Setting range Electronic 9 RV0 -EA0 AC 0 V, 0/0 Hz RT0 -AL0 DC V RT0 -BB0 AC/DC 0 0 V ) RW0 -AB RU -EB0. 0 RV0 -FA0 RV0 -GA0 0 0 RV0 -HA0 AC 0 V, 0/0 Hz RT0 -AL0 DC V RT0 -BB0 AC 0 V, 0/0 Hz RT0 -AL0 DC V RT0 -BB0 AC/DC V ) RW0 -AB0 AC/DC 0 0 V ) RW0 -AB AC/DC V ) RW0 -AB0 AC/DC 0 0 V ) RW0 -AB 0 RU -FB0 RU -GB0 0 0 RU -HB0 0 RB0 - UB0 Class 0 Class 0 ) AC/DC V ) RW0 -AB0 S
14 S design Direct start Reversing start Assembly kit for rail mounting RA9 -B comprising: wiring kit rail adapter side modules link wedges Version Version Size S circuit breaker Size S circuit breaker Link module AC RA9 -AA00 DC RA9 -BA00 Size S contactor Rail adapter RA9 -A, Size S connectors Mechanical interlock RA9 -B Link module AC RA9 -AA00 DC RA9 -BA00 Rail adapter RA9 -AA00 Side modules for rail adapters RA9 0-B ( = 0 adapters) Link wedge ( = 00 wedges) US9 9-AA00 Wiring kit: RA9 -A upper link module, lower link module
15 S selection and ordering data ) For rated device operating voltage Ve: 00 0 V (Ve: 0 V refer to Catalog) ) When using tripping class CLASS 0 refer to the information in the engineering support Engineering fuseless load feeders and also in the Catalog ) Fan available as accessory -phase motor AC-/00 V [kw] Circuit breakers (MSP) Contactors Soft starters Overload relays Setting range CLASS 0 Control Aux- supply iliary voltage switches Control supply voltage Rated operating current ) le Setting range CLASS 0 Thermal Setting range Electronic 0 RV0 -JA0 AC 0 V, 0/0 Hz RT0 -AL0 DC V RT0 -BB0 AC/DC 0 0 V ) RW0 -AB RU -JB0 0 0 RV0 -KA RV0 -LA RV0 -MA0 AC 0 V, 0/0 Hz RT0 -AL0 DC V RT0 -BB0 AC 0 V, 0/0 Hz RT0 -AL0 DC V RT0 -BB0 AC/DC V ) RW0 -AB0 AC/DC 0 0 V ) RW0 -AB AC/DC V ) RW0 -AB0 AC/DC 0 0 V ) 00 RW0 -AB RU -KB RU -LB RU -MB0 00 RB0 - EB0 Class 0 Class 0 ) AC/DC V ) 00 RW0 -AB0 S
16 S, S0, S selection and ordering data S Contactors Overload relays Soft starters -phase motor AC-/00 V [kw] Electromagnetic Control Auxiliary Contactor Vacuum operating supply switches contactor mechanism voltage [AC/DC V] Setting Electronic Version range CLASS 0 Control supply voltage Rated operating current ) le Conventional 0 0 NO + NC RT0-AP Electronic for V DC PLC output 00 NO + NC RT0-NP for V DC PLC output w/ RLT ) 00 NO + NC RT0-PP with AS-i interface and RLT ) 00 NO + NC RT0-QP 0 Conventional 0 0 NO + NC RT0-AP Electronic for V DC PLC output 00 NO + NC RT0-NP for V DC PLC output w/ RLT ) 00 NO + NC RT0-PP with AS-i interface and RLT ) 00 NO + NC RT0-QP 0 00 RB0 - FW0 with straightthrough transformer 0 00 RB0 - FG0 with busbar connection AC 0 V RW0 -BB AC V RW0 -BB AC 0 V RW0 -BB 90 Conventional 0 0 NO + NC RT0-AP Electronic for V DC PLC output 00 NO + NC RT0-NP for V DC PLC output w/ RLT ) 00 NO + NC RT0-PP with AS-i interface and RLT ) 00 NO + NC RT0-QP Class 0 Class 0 ) AC V RW0 -BB
17 S0 0 Conventional 0 0 NO + NC RT0-AP RT-AP Electronic for V DC PLC output 00 NO + NC RT0-NP RT-NP for V DC PLC output w/ RLT ) 00 NO + NC RT0-PP with AS-i interface and RLT ) 00 NO + NC RT0-QP 0 RB0- GG0 with busbar connection AC 0 V 0 RW0 -BB 0 00 Conventional 0 0 NO + NC RT0-AP RT-AP Electronic for V DC PLC output 00 NO + NC RT0-NP RT-NP for V DC PLC output w/ RLT ) 00 NO + NC RT0-PP with AS-i interface and RLT ) 00 NO + NC RT0-QP Conventional 0 0 NO + NC RT0-AP RT-AP Electronic for V DC PLC output 00 NO + NC RT0-NP RT-NP for V DC PLC output w/ RLT ) 00 NO + NC RT0-PP with AS-i interface and RLT ) 00 NO + NC RT0-QP 00 0 RB0- KG0 with busbar connection AC V 0 RW0 -BB AC 0 V 0 RW0 -BB AC V 0 RW0 -BB S Conventional 0 0 NO + NC RT0-AP RT-AP Electronic for V DC PLC output 00 NO + NC RT0-NP RT-NP for V DC PLC output w/ RLT ) 00 NO + NCRT0-PP with AS-i interface and RLT ) 00 NO + NC RT0-QP Conventional 0 0 NO + NC RT0-AP RT-AP Electronic for V DC PLC output 00 NO + NC RT0-NP RT-NP for V DC PLC output w/ RLT ) 00 NO + NC RT0-PP with AS-i interface and RLT ) 00 NO + NC RT0-QP 00 0 RB0- KG0 with busbar connection Class 0 Class 0 ) AC 0 V RW0 -BB AC V RW0 -BB AC 0 V RW0 -BB AC V RW0 -BB For applications above 00 A, contactors can be combined with SENTRON VL circuit breakers. For more detailed information please refer to the engineering brochure Engineering fuseless load feeders. ) For rated device operating voltage Ve: 00 0 V (Ve: V refer to Catalog) ) When using tripping class CLASS 0 refer to the information in the engineering document Engineering fuseless load feeders and as well as in the Catalog ) RLT: Remaining lifetime SENTRON VL circuit breakers are suitable for fuseless short circuit and overload protection for soft starters from Size S. For more detailed information, please refer to the Catalog. S, S0, S
18 Completely mounted/assembled load feeders Fuseless load feeders -phase motor AC-/00 V [kw] Setting range, thermal overload release RA coordination type 0 V AC direct RA coordination type 0 V AC reversing Size RA coordination type 0 V AC direct RA coordination type 0 V AC reversing Size RA 0-0BA-AP0 RA 0-0CA-AP0 RA 0-0DA-AP0 RA 0-0EA-AP0 RA 0-0FA- AP0 RA 0-0GA-AP0 RA 0-0HA-AP0 RA 0-0JA -AP0 RA 0-0KA-AP0 RA 0-AA-AP0 RA 0-BA-AP0 RA 0-0BA-0AP0 RA 0-0CA-0AP0 RA 0-0DA-0AP0 RA 0-0EA-0AP0 RA 0-0FA- 0AP0 RA 0-0GA-0AP0 RA 0-0HA-0AP0 RA 0-0JA- 0AP0 RA 0-0KA-0AP0 RA 0-AA-0AP0 RA 0-BA-0AP0 S00 Coordination type also fulfills coordination type Coordination type also fulfills coordination type S RA 0-CA-0AP0 RA 0-DA-0AP0 RA 0-EA-0AP0 RA 0-FA -0AP0 RA 0-GA-0AP0 RA 0-HA-0AP0 RA 0-JA -0AP0 RA 0-KA-0AP0 RA 0-AA-0AP0 RA 0-BA-0AP0 RA 0-CA-0AP0 RA 0-DB-0AP0 RA 0-EB -0AP0 RA 0-FB -0AP0 RA 0-GB-0AP0 RA 0-HB-0AP0 RA 0-CB- 0AP0 RA 0-DB-0AP0 RA 0-EB- 0AP0 RA 0-FB- 0AP0 RA 0-GB-0AP0 RA 0-HB-0AP0 RA 0-JB- 0AP0 RA 0-KB-0AP0 RA 0-AB-0AP0 RA 0-BB- 0AP0 RA 0-CB- 0AP0 S0 S RA 0-CA-AP0 RA 0-DA-AP0 RA 0-EA-AP0 RA 0-FA- AP0 RA 0-GA-AP0 RA 0-HA-AP0 RA 0-JA- AP0 RA 0-KA-AP0 RA 0-AA-0AP0 RA 0-BA-0AP0 RA 0-CA-0AP0 RA 0-DA-0AP0 RA 0-CA-0AP0 RA 0-DA-0AP0 RA 0-EA-0AP0 RA 0-FA- 0AP0 RA 0-GA-0AP0 RA 0-HA-0AP0 RA 0-JA- 0AP0 RA 0-KA-0AP0 RA 0-AB-0AP0 RA 0-BB- 0AP0 RA 0-CA-0AP0 RA 0-DB-0AP0 S00 S0 S0 S
19 Infeed system Version -phase busbars -phase busbars to expand the system incl. RV9 -BA00 expansion connector for switches RV9 -A -phase busbars to expand the system incl. RV9 -BA00 expansion connector for switches RV9 -B -phase busbars with infeed left incl. RV9 -A end cover for switches RV9 -A -phase busbars with infeed right incl. RV9 -A end cover for switches RV9 -E Connector Connector to connect to the circuit breaker S00, Cage clamp unit RV9 -AA00 0 units RV9 -A to connect to the circuit breaker S0, screw unit RV9 -AA00 0 units RV9 -A Accessories Contactor base to configure direct or reversing starters unit RV9 -AA00 0 units RV9 -A Terminal block to integrate, or -pole components RV9 -D -phase busbar to expand the system -phase busbar with infeed Connector Contactor base for load feeders Terminal block Rail Expansion connector End cover Mounting rail to integrate other devices into the system, e.g. SY cable protection circuit breakers RV9 -B Spare parts Expansion connector as spare part RV9 -BA00 End cover as spare part RV9 -A Fuseless load feeders, infeed system
20 Reversing combinations and Star-delta combinations Reversing combinations up to kw Star-delta combinations up to kw S00 S00 Reversing combinations -phase motor Size Pre-wired and AC-/00 V tested for 0 V AC, 0/0 Hz [kw]. S00 RA -XB0-AP0 S0 RA -XB0-AL. 9 S00 RA -XB0-AP0 S0 RA -XB0-AL S00 RA -XB0-AP0 S0 RA -XB0-AL S RA -XB0-AL. 0 S RA -XB0-AL 0 S RA -XB0-AL 0 S RA -XB0-AL S RA -XB0-AL 9 S RA -XB0-AL Contactors combinations -phase motor Size Pre-wired and AC-/00 V tested for 0 V AC, 0/0 Hz [kw]. S00-S00-S00 RA -XB-AP0. S00-S00-S00 RA -XB-AP0 S0-S0-S0 RA -XC-AL /. /0 S0-S0-S0 RA -XC-AL /0 0/ S-S-S0 RA -XC-AL 0 S-S-S RA -XC-AL S-S-S RA -XC-AL S-S-S RA -XC-AL 0 S-S-S RA -XC-AL
21 Completely assembled load feeders Safety-related load feeders -phase motor AC-/00 V [kw] Setting range, thermal overload release Coordination type 0 V AC Category according to EN 9- Coordination type V DC Size RA 0-0AA-0AL RA 0-0BA-0AL RA 0-0BA-0AL RA 0-0DA-0AL RA 0-0EA-0AL RA 0-0FA-0AL RA 0-0GA-0AL RA 0-0HA-0AL RA 0-0JA-0AL RA 0-0KA-0AL RA 0-AA-0AL RA 0-BA-0AL RA -0AA-0AB RA -0BA-0AB RA -0BA-0AB RA -0DA-0AB RA -0EA-0AB RA -0FA-0AB RA -0GA-0AB RA -0HA-0AB RA -0JA-0AB RA -0KA-0AB RA -AA-0AB RA -BA-0AB S RA 0-CA-0AL RA 0-DA-0AL RA 0-EA-0AL RA 0-FA-0AL RA 0-GA-0AL RA 0-HA-0AL RA 0-JA-0AL RA 0-KA-0AL RA 0-AA-0AL RA 0-BA-0AL RA 0-CA-0AL RA RA RA RA RA RA RA RA RA RA RA -CA-0AB -DA-0AB -EA-0AB -FA-0AB -GA-0AB -HA-0AB -JA-0AB -KA-0AB -AA-0AB -BA-0AB -CA-0AB S0 S00 without RA 00-AA-0AL RA 0-AA-0AB Circuit breaker (contactor-safety combination) 0 Safety electronics as basic unit up to Category Safety electronics as basic unit up to Category Safety electronics as expansion unit Safety electronics as expansion unit, time delay 0.0 s Safety electronics as expansion unit, time delay s Star-delta combination, reversing combination, safety-related load feeders
22 Accessories oor Circuit -coupling breakers r otary oper ating mecha ni sm s Version For Size Insulated -phase busbar systems -phase busbars, modular spacing mm for switches S00, S0 RV9 -AB for switches RV9 -BB for switches RV9 -CB for switches RV9 -DB Connector from S0 to S00 S00, S0 RV9 -DB -phase busbars, modular spacing mm for switches S RV9 -A for switches RV9 -B for switches RV9 -C Version For Size NSB0000a -phase line-side terminal, connection from the top S00 RV9 -A S0 RV9 -AB S RV9 -A Door-coupling rotary operating mechanisms Black Extension shaft 0 mm S0, S, S RV9-0B Extension shaft 0 mm RV9-0K with support bracket Transverse auxiliary CO S00, S0, S, S RV9 0-D switch NO + NC RV9 0-E NO RV9 0-F Transverse auxiliary NO + NC S00, S0, S, S RV9 0-A switch with contacts NO RV9 0-B NC RV9 0-C Transverse auxiliary NO + NC S00, S0, S, S RV9 0-J switch with contacts Shunt 0 V AC S00, S0, S, S RV9 0-DP0 release Undervoltage release 0 V AC S00, S0, S, S RV9 0-AP0 Undervoltage release 0 V AC S00 RV9 -CP0 with leading S0, S, S RV9 -CP0 auxiliary switches Signaling switch S0, S, S RV9 -M Isolator module S0 RV9 -A S RV9 -A Moulded-plastic enclosure for wall mounting With actuator diaphragm width mm S00 RV9 -CA00 (e.g. switch + transverse auxiliary switch) width mm S00 RV9 -DA00 (e.g. switch + transverse auxiliary switch + auxiliary release) With rotary operating mechanism width mm S0 RV9 -CA00 (e.g. switch + transverse auxiliary switch) width mm S0 RV9 -DA00 (e.g. switch + transverse auxiliary switch + auxiliary release)
23 Accessories Contactors S00 Version Contactor (example) kw/00 V, NO RT0 -AP0 control supply voltage 0 V, 0/0 Hz Solid-state time-delay block 0. 0 s RT9 -CH ON delay Solid-state time-delay block 0. 0 s RT9 -DH OFF delay Auxiliary switch block, solid-state time-delay ON delay 0. 0 s RT9 -ED OFF delay 0. 0 s RT9 -FL -pole auxiliary switch block, NO RH9 -AA0 cable entry from above NC RH9 -AA0 9 -pole auxiliary switch block, NO + NC RH9 -LA cable entry from above -pole auxiliary switch block, NO RH9 -BA0 cable entry from below NC RH9 -BA0 -pole auxiliary switch block, NO + NC RH9 -MA cable entry from below -pole auxiliary switch block, NO + NC RH9 -HA (terminal designations acc. to DIN EN 0 0) 0 -pole auxiliary switch block, NO + NC RH9 -NF solid-state compatible design (acc. to DIN EN 0 00) Solder pin adapter for for contactors RT9 -KA the basic unit (package) Surge suppressor 0 V AC RT9 -JL00 with LED (varistor) V DC RT9 -JJ00 Surge suppressor 0 V AC RT9 -BD00 without LED (varistor) 0 V DC RT9 -BB00 Link for paralleling, RT9 -BA (star jumper), -pole, without terminal Link for paralleling, RT9 -BB -pole, with terminal Link for paralleling, RT9 -BB -pole, with terminal nd Koppelschütze e S00 mit Zubehör schütz nischer Zeitrelaisblock, ansprechverzögert für Schütze für Schütze und Koppelschütze (Interface Accessories
24 Accessories Contactors S0 S 9 Version For Size Contactor, size S0 (example). kw/00 V RT0 -AP00 control supply voltage 0 V, 0 Hz For sizes S0 to S: Solid-state time-delay block, ON delay 0. 0 s RT9 -CH Solid-state time-delay block, OFF delay 0. 0 s RT9 -DH Auxiliary switch block, solid-state time-delay ON delay 0. 0 s RT9 -ED OFF delay 0. 0 s RT9 -FL -pole auxiliary switch block, cable entry from above NO + NC RH9 -LA -pole auxiliary switch block, cable entry from below NO + NC RH9 -MA -pole auxiliary switch block (terminal designations acc. to DIN EN 0 0) NO + NC RH9 -HA Link for paralleling (star jumper), -pole, S0 RT9 -BA without terminal S RT9 -BA S RT9 -BA Link for paralleling, -pole, with terminal S0 RT9 -BB S RT9 -BB S RT9 -BB -pole auxiliary switch block, can be laterally mounted (left or right) NO + NC S0 S RH9 -DA (terminal designations acc. to DIN EN 00) Single-pole auxiliary switch block (up to can be snapped on) NO S0 S RH9 -CA0 NC S0 S RH9 -CA0 Mechanical interlock, can be laterally mounted S0 S RA9 -B Mechanical interlock, can be mounted at the front S0 S RA9 -A Wiring connectors at the top and bottom S0 RA9 -A (reversing operation) plugging S RA9 -A S RA9 -A Surge suppressor (varistors), S0 S RT9 -BD00 can be mounted at the top or bottom Interface for mounting directly onto the contactor coil S0 S RT9 -AB LED module to indicate contactor operation S0 S RT9 -QT00 Mechanical latching AC/DC S0, S RT9 -AB 0 AC/DC S0, S RT9 -AF 0 AC/DC S0, S RT9 -AP
25 Accessories Contactors S S Operating mechanism types RT0 and RT air contactors, Sizes S, S0 and S RT vacuum contactor, Sizes S0 and S Withdrawable coils for contactors with conventional operating mechanism RT -.A.. Withdrawable coils for contactors with electronic operating mechanism RT -.N.. Withdrawable coils and laterally mounted module (can be plugged in) for contactors with electronic operating mechanism and remaining lifetime signal RT -.P.. and RT -.Q Version -pole auxiliary switch block, can be laterally mounted nd block (left/right), DIN EN 0 0 NO + NC RH9 -JA nd block (left/right), DIN EN 0 00 NO + NC RH9 -KA NO RH9 -KA0 -pole auxiliary switch block, can be mounted at the front with classification No., DIN EN 0 0 NO + NC RH9 -XA-0MA0 with classification No., DIN EN 0 0 NO + NC RH9 -HA Single-pole auxiliary switch block, NO RH9 -CA0 can be mounted at the front NC RH9 -CA0 -pole auxiliary switch block, NO + NC RH9 -LA can be mounted at the front cable entry from above, DIN EN pole auxiliary switch block, NO + NC RH9 -MA can be mounted at the front cable entry from below, DIN EN 0 00 Auxiliary switch block, solid-state time-delay NO + NC ON delay, 00 0 V AC 0. 0 s RH9 -ED OFF delay, 00 0 V AC 0. 0 s RH9 -FL Version RC element, 0 V AC Connection cover for S RT9 -CD00 RT9 -EA for busbar connection for S0/S RT9 -EA 9 Connection cover for S RT9 -EA for box terminals for S0/S RT9 -EA 0 Box terminal block for S to 0 mm RT9 -G to 0 mm RT9 -G for S0/S to 0 mm RT9 -G Link for paralleling for S RT9 -BA for S0/S RT9 -BA Mechanical interlock Wiring connectors, top for S RA9 -A RA9 -A and bottom (reversing operation) for S0 RA9 -A plugging for S RA9 -A Size -phase Contactor Withdrawable coil for operating mechanism motor without coil conventional electronic AC-/00 V control supply voltage 0 0 V AC/DC 00 V AC/DC kw S RT0 -LA0 RT9 -AP RT9 -NP RT0 -LA0 90 RT0 -LA0 S0 0 RT0 -LA0 RT9 -AP RT9 -NP RT0 -LA0 0 RT0 -LA0 S 00 RT0 -LA0 RT9 -AP RT9 -NP 0 RT0 -LA0 Accessories
26 Accessories Accessories for RU thermal overload relays and RB0 electronic overload relays Version For Size Adapter for single mounting to separately mount the overload relay, S00 RU9 -AA0 screw and snapping onto mm rails, S0 RU9 -AA0 Size S also for mm rail S RU9 -AA0 S RU9 -AA0 Version For Size Sealable cover, transparent to cover the setting elements for RB0 S00 to S0/S RB9 00-B Mechanical RESET comprising: Resetting plunger, holder and former S00 to S0/S RU9 00-A Matching push button IP, mm diameter S00 to S0/S SB0 00-0EA Extension plunger S00 to S0/S SX Terminal covers Cover for cable lug S RT9 -EA and busbar connection S RT9 -EA S0/S RT9 -EA Cover for box terminals S RT9 -EA S RT9 -EA S RT9 -EA S0/S RT9 -EA Cover for the screw connection S RT9 -EA between the contactor and S0/S RT9 -EA overload relay without box terminals (x is required for each combination) Block for electrical remote RESET with operating range 0. to. x V s Power drain 0 VA AC 0 W DC and switch-on duration 0. to s operating frequency, 0/h to 0 V AC/DC S00 to S0/S RU9 00-AB 0 to V AC/DC S00 to S0/S RU9 00-AF 0 to 0 V AC/DC S00 to S0/S RU9 00-AM Cable release with holder for RESET for holes. mm diameter length 00 mm S00 to S0/S RU9 00-B in the panel; length 00 mm S00 to S0/S RU9 00-C max. panel thickness, mm Box terminal block for round and ribbon cables to 0 mm S RT9 -G to 0 mm S RT9 -G S0/S RT9 -G
27 Enclosures for motor starters -phase motor Enclosure for Size Components required Qty. AC-/00 V direct starters [kw]. Moulded-plastic enclosure S00 RE9-CB Contactor with integrated RT for wall mounting auxiliary switch NO IP degree of protection with actuator elements Thermal or electronic RU resp. overload relay RB0 Moulded-plastic enclosure S0 RE9-CB Contactor RT0 for wall mounting IP degree of protection Thermal or electronic RU resp. with actuator elements overload relay RB0 Lateral auxiliary switch RH9 -DA NO/NC Moulded-plastic enclosure S RE9-CB Contactor RT0 for wall mounting IP degree of protection Thermal or electronic RU resp. with actuator elements overload relay RB0 Lateral auxiliary switch RH9 -DA NO/NC -phase motor Enclosure for Size Components required Qty. AC-/00 V reversing starters [kw]. Moulded-plastic enclosure S00/S0 RE9-CB Contactor RT0 for wall mounting IP degree of protection Wiring kit for reversing RH9 -A with actuator elements combination Thermal or electronic RU resp. overload relay RB0 Auxiliary switch NO at the front RH9 -BA0 Moulded-plastic enclosure S00/S0 RE9-CB Contactor RT0 for wall mounting IP degree of protection Wiring kit for reversing RH9 -A with actuator elements combination Direct and reversing starters in enclosures are also available pre-configured. These include all of the necessary components and are pre-wired with the exception of the overload relay. The overload relay should be selected corresponding to the application and must be separately ordered. For more detailed information, please refer to the Catalog. Mechanical interlock RH9 -B Thermal or electronic RU resp. overload relay RB0 Auxiliary switch NO at the front RH9 -CA0 Accessories
28 Ordering by fax +9/9/9- CD/Z SWITCHING PROTECTING STARTING Please send me the selected information to the following address: Siemens AG Industrial Controls Switching Protecting Starting Soft starters Automation and Drives Low-Voltage Switchgear P.O. Box, 90 Nuremberg Name Street, Postal Code/City Telephone/Fax Solid-state industrial controls Infeed system Engineering load feeders MONITORING AND CONTROLLING DETECTING COMMANDING AND SIGNALING SUPPLYING ENGINEERING AND MORE Relays Detecting Commanding and signaling Supplying Switch ES Motorstarter The engineering tool for high-feature motor starters Modular System Cage Clamp terminals Motor Management SIMOCODE pro TK safety relays Standard position switches Safe detection devices SIDAC & SIVENT Solutions for Individual Applications Safety Integrated ECOFAST AS-Interface The information provided in this brochure contains merely general descriptions or characteristics of performance which in actual case of use do not always apply as described or which may change as a result of further development of the products. An obligation to provide the respective characteristics shall only exist if expressly agreed in the terms of contract. Subject to change without prior notice 0/0 I E000-A0-P0-X-00 I Dispo 0 I C MK.CD.SG.SGSR...0 PA 00.0 I Printed in Germany I Siemens AG 00
sirius Switching. Protecting. Starting. SIRIUS Product Overview
sirius Switching. Protecting. Starting. SIRIUS Product Overview S00 Design Direct-on-line starting Reversing duty Assembly kit for busbar mounting 0 mm: RA9 -C 0 mm: RA9 -D Consisting of: wiring kit busbar
More informationSystem-based switching, protecting, starting. SIRIUS Modular System. sirius
System-based switching, protecting, starting. Modular System. sirius Everything for the electrical cabinet: Modular System. Contents S00 structure S00 selection and ordering data: Circuit breakers, contactors,
More informationSiemens AG Highly flexible system-based switching, protecting and starting. SIRIUS Modular System. Answers for industry.
Siemens AG 00 Highly flexible system-based switching, protecting and starting. SIRIUS Modular System SIRIUS Answers for industry. Everything for the electrical cabinet: SIRIUS Modular System. Press Shop
More informationClick 'n' Go: SIRIUS Modular System SIRIUS. Highly flexible system-based switching, protecting and starting. Answers for industry.
Click 'n' Go: SIRIUS Modular System SIRIUS Highly flexible system-based switching, protecting and starting. Answers for industry. s Everything for the electrical cabinet: SIRIUS Modular System. Contents
More informationSIGUARD Safety Combinations and Safe Load Feeders. safety INTEGRATED
SIGUARD Safety Combinations and Safe Load Feeders safety INTEGRATED EMERGENCY Topmost priority protection of man, machine and the environment The topmost priority is to protect man, machine and the environment
More informationSIRIUS Modular System
SIRIUS Modular System Highly flexible system-based switching, protecting and starting siemens.com/sirius Answers for industry. Everything for the electrical cabinet: SIRIUS Modular System. Contents SIRIUS
More informationSIRIUS modular system
SIRIUS modular system Switching, protecting, starting and monitoring with the highly flexible modular system siemens.com/sirius Everything for the control cabinet: the SIRIUS modular system. Press shop
More informationSIRIUS modular system
SIRIUS modular system Switching, protecting, starting and monitoring with the highly flexible modular system siemens.com/sirius Everything for the control cabinet: the SIRIUS modular system. Press shop
More informationSwitching, protecting, starting and monitoring with the highly flexible modular system usa.siemens.com/controls
SIRIUS Modular System. The perfect combination Switching, protecting, starting and monitoring with the highly flexible modular system usa.siemens.com/controls Everything for the control cabinet: the SIRIUS
More informationContactors and Contactor Assemblies
SIRIUS Contactors and Contactor Assemblies Application WYE-delta starting can only be used either if the motor normally operates in a d (delta) connection or starts softly or if the load torque during
More information3RA13, 3RA14 Contactor Assemblies
RA1, RA Contactor Assemblies RA1 complete units,... kw Overview The RA1 reversing contactor assemblies can be ordered as follows: Sizes S00 to S Fully wired and tested, with mechanical and electrical interlock
More information3RT, 3TB, 3TF Contactors for Switching Motors
RT, TB, TF Contactors for Switching Motors Overview RT contactors and coupling relays Size S00 with mountable accessories The SIRIUS generation of controls is a complete, modular system family, logically
More informationIEC Contactors. Auxiliary Contact Blocks GENERAL
IEC Contactors Auxiliary Contact Blocks GENERAL Description 3RH19 Auxiliary contact blocks The 3RH19 auxiliary contact blocks are available in 1, 2, 3 and 4-pole front mount versions and 2-pole side mount
More informationContactors and Contactor Assemblies
RT contactors, size S00 The product range at a glance The new generation is a complete, modular system family, logically designed right down to the last detail, from the basic units to the accessories.
More informationLoad Feeders and Motor Starters for Use in the Control Cabinet
Load Feeders and Motor Starters for Use in the Control Cabinet Price groups 12W, 14O, 230, 241, 250, 260, 41B, 41D, 41E, 41L, 42C, 42D, 42F, 471, 4N1, 5K1, 5K2, 5N2, 764, 15, 16 /2 Introduction SIRIUS
More informationFor Efficiency and Reliability in the Control Cabinet. The SIRIUS 3RA6 Compact Starter SIRIUS. Answers for industry.
For Efficiency and Reliability in the Control Cabinet The SIRIUS 3RA6 Compact Starter SIRIUS Answers for industry. Highlights Space savings in the control cabinet, thanks to compact design Minimized engineering,
More informationSimply on. Simply off. Day and Night. sirius SWITCHING
Simply on. Simply off. Day and Night. sirius SWITCHING SIRIUS-Funktionen im Überblick Switching Protecting Starting Monitoring and controlling Detecting Commanding and signaling Supplying Engineering SIRIUS
More informationLoad Feeders and Motor Starters for Use in the Control Cabinet
Load Feeders and Starters for Use in the Control Cabinet rice groups G W, 4O, 30, 4, 50, 60, 4B, 4D, 4E, 4L, 4C, 4D, 4F, 47, 4N, 5K, 5K, 5N, 764, 5, 6 / Introduction SIRIUS 3RA load feeders /4 General
More informationContactors and Contactor Assemblies
Contactor Industrial Controls Product Catalog 07 Section c o n t e n t s Section Overview / - /5 Product Overview /6 - /7 Contactors 3RT0, 3-pole to 95 /8 3RT0, 3-pole to 500 /9 3RT, 3-pole Vacuum to 500
More informationCombinable for All Applications
Combinable for All Applications 3SE5 Position Switches www.siemens.com/sirius-detecting The Clever Answer to Information Diversity in the Field The Comprehensive Range of Position Switches 3SE5 position
More informationSIEMENS AG For Efficiency and Reliability in the Control Cabinet. The SIRIUS 3RA6 Compact Starter SIRIUS. Answers for industry.
For Efficiency and Reliability in the Control Cabinet The SIRIUS 3RA6 Compact Starter SIRIUS Answers for industry. Highlights Space savings in the control cabinet, thanks to compact design Minimized engineering,
More informationThe complete universe of Industrial Controls. You have it at your fingertips. sirius
The complete universe of Industrial Controls. You have it at your fingertips. sirius Control room Bodyshop Powertrain Assembly Paintshop Equipping, handling, transporting basic functions such as these
More informationIEC Power Control Contactors and Contactor Assemblies
IEC Power Control Contactors and Contactor ssemblies Contents Pages Contents Pages Section Overview......................... / - /5 Product Overview......................... /6 - /7 Contactors 3RT0 / 3RT0,
More informationSiemens AG RA6 Fuseless Compact Starters. Catalog News LV 1 N April 2008 SIRIUS.
3RA Fuseless Compact Starters Catalog News LV 1 N April 2008 SIRIUS www.siemens.com/lowvoltage 3RA Fuseless Compact Starters General data Overview 3RA fuseless compact starters and infeed system for 3RA
More informationLoad Feeders, Motor Starters and Soft Starters
Load Feeders, Motor Starters and Soft Starters Catalog Technical Information 3RA Fuseless Compact Starters /2 General data /2 - Overview /3 - Benefits 3RA1, 3RA2 Compact Starters /4 3RA1 direct-on-line
More informationProtection Equipment
Protection Equipment Price groups 41B, 41E, 41F, 41G, 41H, 41J, 42F, 42J, 143, 401 /2 Introduction Motor starter protectors/ circuit breakers SIRIUS 3RV2 motor starter protectors up to 40 A / General data
More informationSolid-State Switching Devices
Controls Solid-State Switching Devices /2 Introduction Solid-State Switching Devices /3 General data Solid-State Switching Devices for Resistive Loads /5 General data Solid-State Relays /7 General data
More information3RV1 Circuit-Breakers
SIRIUS 3R Description Mountable accessories 3RV1 Circuit- Breakers Circuit-breaker S00 with mountable accessories 3 2 1 5.1 NSK-7715a 4 Circuit-breaker S0 with mountable accessories 1 7 3 5.2 2 6 NSK-7716a
More informationEasy, efficient and always up to date the SIRIUS modular system
Easy, efficient and always up to date the SIRIUS modular system siemens.com/sirius Easy, efficient and always up to date, that s how industrial controls can be! Switching Protecting Starting Monitoring
More informationIndustrial Controls Product Catalog RA64 / 3RA65 up to 32 A for mounting rail, surface,
Combination Starters Industrial Controls Product Catalog 2017 Section c o n t e n t s Self Protected Motor Starters per UL 508 Type E 3RA6 3RA61 / 3RA62 up to 32 A for mounting rail, surface, comb busbar,
More informationSIRIUS Monitoring and Controlling. Overview of safety relays. Safety Integrated. Answers for industry.
SIRIUS Monitoring and Controlling Overview of safety relays Safety Integrated Answers for industry. Simpler, faster and more cost-effective to implement a seamless safety chain Today, one of the key success
More information4 COMBINATION SIRIUS. SIRIUS 3RA6 Compact Starters 4/2. General data
Combination Starters Industrial Controls Product Catalog 2019 Section contents Self Protected Motor Starters per UL 508 Type E RA6 RA61 / RA62 up to 2 A for mounting rail, surface, comb busbar, infeed
More informationSafety is a SIRIUS business
SIRIUS 3SK Safety Relays Safety is a SIRIUS business Safety Relays for compact safety applications usa.siemens.com/safety-relays Safety is a SIRIUS business Machines can be dangerous. Personnel need to
More informationSiemens.com/industrial-controls
SIRIUS Industrial Controls List 2018 Siemens.com/industrial-controls List of Contents Motor Control and Protection Soft Starters Motor Management - Simocode Monitoring Relays Commanding and Signaling Devices
More informationHow Can Control Panels Be Assembled Faster?
How Can Control Panels Be Assembled Faster? With the SIRIUS Innovations, Everything is Matched: Click n Go. Answers for industry. How Can Control Panels Be Assembled Faster? Systematic advancement SIRIUS
More informationSwitches 6/1. 6/4 Introduction. 6/5 5TE8 control switches. 6/7 5TE4 8 pushbuttons. 6/9 5TE8 On/Off switches. 6/11 5TE1 switch disconnectors
6/4 Introduction 6/5 5TE8 control switches 6/7 5TE4 8 pushbuttons 6/9 5TE8 On/Off switches 4 6/11 5TE1 switch disconnectors 6 6/1 Switch to manual? Wherever electrical systems need to be switched on or
More informationSIMATIC S plus TIA Portal
Product range overview SIMATIC S7-1500 plus TIA Portal Power + Efficiency The ultimate plus in automation Intuitive, efficient, proven TIA Portal redefines engineering Answers for industry. Your plus of
More informationIMS Control & EPR, We keep your motors running ABB s new control & protection devices up to 18.5 kw / 20 hp
IMS Control & EPR, 2010 01 29 We keep your motors running ABB s new control & protection devices up to 18.5 kw / 20 hp October 27, 2010 1SBC101089D0201 ABB s new control and protection devices Up to 18.5
More informationStandards and approvals
2 SIRIUS controls contactors and contactor assemblies 4 SIRIUS controls solid-state switching devices 4 SIRIUS protective devices 8 SIRIUS load feeders and compact starter 12 SIRIUS Circuit Breaker 12
More informationSIRIUS 3RB24 Solid-State Overload Relays with Complete Starter Functionality via IO-Link
SIRIUS 3RB24 Solid-State Overload Relays with Complete Starter Functionality via IO-Link Integrated Motor Protection for High-Feature Applications siemens.com/sirius Answers for industry. SIRIUS 3RB24
More information3RM1 Hybrid Starters 6SIRIUS. contents. Industrial Controls Product Catalog 2017
3RM1 Hybrid Starters Industrial Controls Product Catalog 2017 Section contents 3RM1 Compact - Hybrid Starters Overview /2 General Data /3 Selection and ordering data /4 Accessories /5 - /9 Technical Data
More informationSIRIUS Overload Relays. SIRIUS 3RB24 Solid-State Overload Relays with Complete Starter Functionality via IO-Link
Integrated Motor Protection for High-Feature Applications SIRIUS 3RB24 Solid-State Overload Relays with Complete Starter Functionality via IO-Link SIRIUS Overload Relays www.siemens.com/sirius SIRIUS 3RB24
More informationFast Bus Busbar System
Busbar System Industrial Controls Product Catalog 2017 Section c o n t e n t s Fast Bus busbar adapter system mm system Page Selection and ordering data Busbar holders /9 Fast Bus adapter shoes /11 Incoming
More informationFast Bus Fast Bus Busbar System
Fast Bus Busbar System Contents Fast Bus busbar adapter system mm system Page Selection and ordering data Busbar holders /9 Fast Bus adapter shoes /11 Incoming supply terminals /6 Copper busbar /6 Busbar
More informationSENTRON 3VL Molded Case Circuit Breakers
Siemens AG SENTRON VL Molded Case Circuit Breakers Switching, Protection, Measuring and Monitoring Devices For the operating range from A to 00 A, the molded case circuit breaker ensures the optimum overload
More informationSIRIUS 3RB2 Solid-State Overload Relays
SIRIUS 3RB2 Solid-State 3RB20, 3RB21 for standard applications Overview 1 2 2 $ Connection for mounting onto contactors: Optimally adapted in electrical, mechanical and design terms to the contactors and
More informationSentron 3VT circuit breakers Simply Smart: First choice for power distribution
s Sentron 3VT circuit breakers Simply Smart: First choice for power distribution www.siemens.com/industry Sentron 3VT Molded Case Circuit-Breakers - 10-1600Amperes With the standard line of 3VT molded-case
More informationSolid-State Contactors
Solid-state contactors for switching motors The solid-state contactors for switching motors are intended for frequently switching on and off three-phase current operating mechanisms up to 7.5 kw and reversing
More informationSiemens AG SENTRON 3NJ4, 3NJ5 In-Line Fuse Switch Disconnectors up to 2000 A
Switch Disconnectors Introduction Overview All key product features at a glance Compliant with IEC/EN 60439-1, IEC/EN 6094-3 Voltage levels up to 690 V AC Rated operational current from 160 A to 2000 A
More informationOverload Relays. 3RB2 Solid-State Overload Relays. 3RB20, 3RB21 for standard applications. 5/48 Siemens LV Overview
Overload Relays Siemens AG 2009 Overview 1 2 2 (1)Connection for mounting onto contactors: Optimally adapted in electrical, mechanical and design terms to the contactors and soft starters, these connecting
More informationIssued February DATA SHEET 5SX2 MCB. Based on Siemens Industrial Control Catalog
Issued February 2011 DATA SHEET 5SX2 MCB Based on Siemens Industrial Control Catalog General Data Trip characteristics Tripping characteristics acc. to EN 60 898 Tripping characteristic A, -5 Type A characteristic
More informationC E R T I F I C A T E O F C O M P L I A N C E
Issued to: SIEMENS AG I IA CE CP R&D-VI 4 WERNER-VON-SIEMENS-STRASSE 48 92220 AMBERG GERMANY This is to certify that representative samples of Motor Controllers, Magnetic (See following pages for additional
More informationControls Contactors and Contactor Assemblies
Dimensional drawings RT10 contactors, -pole RT10 1 contactors, size S00 with surge suppressor, auxiliary switch block and mounted overload relay 4, 8,6 67 99 106 9 ) Lateral distance to grounded components
More information29 $ Manual Motor Starters FREESHIPPING. MOTOR CONTROLS 25. Features: MMS-32H Frame. MMS-63H Frame.
www.factorymation.com/motorcontrols MOTOR CONTROLS 25 Manual Motor Starters High interrupt capacity Din rail and surface mounting Lockable handle (OFF position) IP20 finger safe terminals Class 10 thermal
More informationIndustrial Controls Product Catalog 2017
Industrial Controls Product Catalog 2017 SIRIUS Section c o n t e n t s Thermal overload relays Solid state overload relays OVERLOAD RU21 overload relays up to 100 A with screw connection, CLASS 10 Page
More information3RA6 Fuseless Compact Starters
3RA Fuseless Compact Starters Catalog News LV 1 N January 2008 www.siemens.com/compactstarter Kataloge rund um SIRIUS SENTRON SIVACON Ausgabe 2008 Siemens AG 2008 Related catalogs Contents Low-Voltage
More informationMiniature circuit breakers for all applications
Miniature circuit breakers for all applications BETA Low-Voltage Circuit Protection Answers for infrastructure. BETA Low-Voltage Circuit Protection: Circuits under Control, Wherever, Whenever. Whether
More informationAllen-Bradley Bulletin 100 Contactors
Allen-Bradley Bulletin 100 Contactors An integrated portfolio of IEC Contactors that save panel-space and energy Features and Benefits: Direct-on-line and reversing contactors Built-in surge suppression
More informationThe complete universe of Industrial Controls. You have it at your fingertips. sirius. Everything. Easy. SIRIUS.
The complete universe of Industrial Controls. You have it at your fingertips. sirius Everything. Easy. SIRIUS. Control room Bodyshop Powertrain Assembly Paintshop Equipping, handling, transporting basic
More informationApproved Standards. Motor Protection Circuit Breaker (MPCB) J7MN. MPCB system (motor protection CLASS 10) Auxiliary contact modules.
Motor Protection Circuit Breaker (MPCB) J7MN MPCB system (motor protection CLSS 0) Rotary and switch types Rated operational current = 2, 25, 50 and 00 Switching capacity up to 2.5 = 00 k/400 V Fixed short-circuit
More informationSolid-State Switching Devices
Overview 3RF21 3RF20 3RF22 3RF23 SIRIUS 3RF2 solid-state switching devices Solid-state switching devices for resistive loads Solid-state relays Solid-state contactors Function modules Solid-state switching
More informationIEC Power Control Overload Relays
IEC Power Control Overload Relays Contents Contents Thermal overload relays Solid state overload relays 3RU21 overload relays up to 100 A with screw connection, CLASS 10 Page Selection and ordering data
More informationInnovations in the Sirius Modular System for greater efficiency in Industrial Controls and in control cabinet construction
Eckard Eberle, Head of the Control Components Business Segment Siemens AG, Nuremberg International Trade Press Conference held on 24 November 2009 in Nuremberg Innovations in the Sirius Modular System
More informationLoad Feeders. Communication-capable load feeders
Load Feeders /2 Introduction Communication-capable load feeders ET 200S /4 ET 200S motor starters /8 Power modules for ET 200S motor starters /9 SIGUARD safety systems for ET 200S motor starters /10 ET
More informationIEC Power Control Overload Relays
IEC Power Control Overload Relays Contents Contents Thermal overload relays Solid state overload relays 3RU11 / 3RU1 overload relays up to 100 A with screw connection, CLASS 10 Page 3RB4 overload relays
More information8WH5 Combination Plug-In Terminals
8WH Combination Plug-In Terminals /2 Introduction / 8WH through-type terminals 1) /7 8WH hybrid through-type terminals with ipo connection /8 8WH9 plugs 1) 1) Also available as a PE version More technical
More informationSITOP in the SIMATIC Design
Siemens AG 2017 /2 Introduction /3 1-phase, 24 V DC (for S7-300 and ET 200M) /9 1-phase, 24 V DC (for S7-1200) /11 1-phase, 24 V DC (for S7-1500 and ET 200MP) /14 3-phase, 24 V DC (ET 200pro) Siemens KT
More informationComponents for Distribution Systems
Components for Distribution Systems /2 Introduction Busbar adapter systems /4 General data /7 40 mm system / 60 mm system /12 Accessories /14 Project planning aids Door-coupling rotary mechanisms /23 General
More informationSiemens AG I IA CE CP R&D-VI 4 WERNER-VON-SIEMENS-STRASSE AMBERG, GERMANY
Issued to: Siemens AG I IA CE CP R&D-VI 4 WERNER-VON-SIEMENS-STRASSE 48 92220 AMBERG, GERMANY This is to certify that Auxiliary Devices representative samples of 3UF70 followed by 0 or 1 followed by 0
More informationMOTOR PROTECTION CIRCUIT BREAKERS
MOTOR PROTECTION CIRCUIT BREAKERS PAGE -2 PAGE -2 SMA Thermal trip adjustment ranges 9-32A (5 choices) Breaking capacity Icu at 400V: 50kA Suitable for mounting in consumer switchboards with minimum 58mm
More informationLarge Frame IEC Contactors
Large Frame IEC Contactors Bulletin 100-E PUBLIC Copyright 2017 Rockwell Automation, Inc. All Rights Reserved. 1 Changing Applications for Contactors There are fewer and fewer traditional large motor starting
More informationSIRIUS - SIRIUS 3RA28
Industrial Controls Switching Devices SIRIUS - SIRIUS 3RA28 Function modules for mounting on 3RT2 contactors Gerätehandbuch Manual Edition 09/2016 siemens.com SIRIUS - SIRIUS 3RA28 function modules for
More informationSIRIUS Motor Management and Control Devices
Overview is a flexible, modular motor management system for motors with constant speeds in the low-voltage performance range. It optimizes the connection between the control system and motor starter, increases
More informationExcerpt from the full range of SIRIUS ACT Push Buttons and Indicator Lights siemens.com/sirius-act
SIRIUS ACT Core spectrum selection guide Excerpt from the full range of SIRIUS ACT Push Buttons and Indicator Lights siemens.com/sirius-act SIRIUS ACT commanding and signaling SIRIUS ACT modern, high-performance
More informationAir Circuit Breakers. 1/2 Introduction
/2 Introduction 3WL air circuit breakers/ non-automatic air circuit breakers /5 Introduction Up to 6300 A (AC), IEC /6 Introduction /9 General data /6 3-pole, fixed-mounted versions /23 3-pole, withdrawable
More informationIndustrial Controls. Protection Devices. Gerätehandbuch. Answers for industry. Edition 09/2014
Industrial Controls Protection Devices SIRIUS Innovations - Thermal Overload Relays SIRIUS 3RU2 / Solid-State Overload Relays SIRIUS 3RB3 Gerätehandbuch Manual Edition 09/2014 Answers for industry. SIRIUS
More informationIndustrial Controls. Motor management and control devices SIMOCODE pro - Application examples. Introduction 1. Application example
Introduction 1 Application example 2 Industrial Controls Motor management and control devices SIMOCODE pro - Application examples Application Manual Example circuits control functions 3 Further application
More informationCLIPLINE complete. The modular terminal block system for all applications
CLIPLINE complete The modular terminal block system for all applications CLIPLINE complete All connection technologies, one system With CLIPLINE complete, the unique modular terminal block system from
More informationSiemens AG KD Switch Disconnectors SENTRON. Edition December Answers for infrastructure and cities.
KD Switch Disconnectors SENTRON Edition December 01 Answers for infrastructure and cities. Related catalogs Low-Voltage Power Distribution and LV 10 Electrical Installation Technology SENTRON SIVACON ALPHA
More informationSIMOCODE 3UF Motor Management and Control Devices
Technical specifications General data applicable to the basic units, current measuring modules, current/voltage measuring modules, expansion modules, decoupling module and operator panel Permissible ambient
More informationOverload Relays 3RU Thermal Overload Relays 3RB Solid State Overload Relays 3UF SIMOCODE pro Intelligent Motor Protection
IEC Power Control Product Overview Alphabetical Product and Catalog Number Index MSPs 3RV20 Motor Starter Protectors 3RV27 & 3RV28 Circuit Breakers 3RA19/29 & 3RV19/29 Accessories 1 Contactors 3RT, 3TF,
More informationSwitch Disconnectors, Main and EMERGENCY-STOP Switches
General data Overview Siemens G 2010 1 2 3 NSE0_01931b 4 5 6 7 1 uxiliary switch (3SB for 3K; 3KX for 3KE) 2 IP20 terminal cover (Operator side) 3 3K switch disconnector 4 rcing contacts (only for 3KE)
More informationOVERLOAD RELAYS POWER & ACTUATION PROVEN. series
POWER & ACTUATION OVERLOAD RELAYS series Need reliable, accurate overload and phase-loss protection for your motors? c3controls Series Bimetallic Overload Relays provide unmatched protection and can be
More informationXT IEC Power Control Contactors, Starters and Overload Relays
May 00 Product Family Overview 9 Contents Features and Benefits Description Page Contactors and Starters Catalog Number Selection................. Non-reversing Contactors.... Reversing Contactors........
More informationSINAMICS DCM Cabinet. DC drive converter cabinets for fast and simple system integration. siemens.com/sinamics. Answers for industry.
DC drive converter cabinets for fast and simple system integration siemens.com/sinamics Answers for industry. Highest performance and integrated intelligence SINAMICS DC MASTER Cabinet is the drive cabinet
More informationTeSys IEC Contactors and Overload Relays
TeSys IEC Contactors and Overload Relays Making High-Fault Short-Circuit Current Ratings Simple Schneider Electric is an industry leader in IEC contactors and overload relays, and is recognized as the
More informationControls Solid-State Switching Devices
Siemens AG 27 Controls Solid-State Switching Devices /2 Introduction Solid-State Switching Devices /3 General data Solid-State Relays /6 General data /7 3RF21 solid-state relays, single-phase, 22.5 mm
More information194E FA 32 E P11 P11 6
Bulletin E IEC Load Switches, A Product Selection/Catalog Number Explanation Bulletin E Enclosed Disconnect Load Switches with R Handles (with Defeater, suitable for padlocks) E-FA Painted Steel Enclosure
More informationSiemens AG Reliable solid-state switching devices. for frequent switching of resistive or motor loads SIRIUS. Answers for industry.
Reliable solid-state switching devices for frequent switching of resistive or motor loads Answers for industry. High switching frequencies, long service life: Solid-State Switching Devices with Added Value
More informationMiniature Circuit Breakers for Railway Applications
Siemens AG 00 for Railway Applications BETA Low-Voltage Circuit Protection The miniature circuit breakers are used in fixed railway systems and rolling stock for protecting system components against overcurrent
More informationC E R T I F I C A T E O F C O M P L I A N C E
Issued to: This is to certify that representative samples of SIEMENS AG DF CP R&D VC 2 WERNER-VON-SIEMENS-STRASSE 48 92224 AMBERG, GERMANY MOTOR CONTROLLERS, MANUAL (See following page for additional information.)
More informationMini Contactors & Overloads
108 Mini s & Overloads GMC-12M Surface or DIN rail mountable UL508 compliant 1/ to 7-1/ 50/60Hz AC and DC versions available Direct-mounting overloads RoHS compliant Auxiliary contacts standard (1 N.0.)
More informationPower Management System. Measuring Devices for Power Distribution
Power Management System Measuring Devices for Power Distribution Power Management System System overview /2 - Overview /2 - More information SENTRON Power Monitoring Devices General data /3 - Overview
More informationJ7MN. Ordering Information. Motor Protection Circuit Breaker. Model Number Legend. MPCB system. Options. Motor Protection Circuit Breaker J7MN I-1
Motor Protection Circuit Breaker J7MN ) MPCB system Rotary and switch types Rated operational current 32 A, 63 A and 00 A Switching capacity up to 00 ka/400 V Fixed short-circuit release = 3 x I u Overload
More informationMotor protection circuit breakers
Wide adjustment range 0. to 00A IEC breaking capacity Icu 50kA (400V) up to 00A Suitable for isolation Comprehensive line of accessories Magnetic-only version Automatic trip indicators High reliability
More informationCS7 Industrial Control Relays
CS7 Industrial Control Relays Reliable, general purpose relays for heavy duty applications The base four pole CS7 relay can be expanded up to twelve poles with the addition of front and side mount auxiliaries
More informationApproved Standards. Motor Protection Circuit Breaker (MPCB) J7MN. MPCB system (motor protection CLASS 10) Auxiliary contact modules.
Motor Protection Circuit Breaker (MPCB) J7MN MPCB system (motor protection CLSS 0) Rotary and switch types Rated operational current = 2, 25, 50 and 00 Switching capacity up to 2.5 = 00 k/400 V Fixed short-circuit
More informationBusbar Systems. 10/2 Introduction. 10/3 General data. 40 mm Busbar Systems 10/6 Introduction 10/7 Base assemblies up to 400 A
Siemens AG 20 Busbar Systems /2 Introduction /3 General data 40 mm Busbar Systems /6 Introduction /7 Base assemblies up to 400 A mm Busbar Systems /8 Introduction /9 Base assemblies up to 630 A /13 Base
More informationMotor Control Products Selection Guide
MKING MODERN LIVING POSSIBLE Motor Control Products Selection Guide Contactors, Relays, and Circuit Breakers www.danfoss.com/ia c o n t e n t s Minicontactors CI 5 Thermal Overload Relays TI 9C for Minicontactors
More informationUS Catalog July 2016 SMISSLINE TP
US Catalog July 2016 SMISSLINE TP SMISSLINE TP modular bus system Table of contents Description 2 Building a SMISSLINE TP assembly for UL 489 and UL 508 based solutions Overview and ordering information
More information