User friendly and easy to program

Size: px
Start display at page:

Download "User friendly and easy to program"

Transcription

1 New Product Digital Panel Meter WPMZ User friendly and easy to program μm m/min mm rpm m/min ton Universal design! New Digital Panel Meter Specification is subject to change without notice Watanabe Electric Industry Co., Ltd. Mail : support@watanabe-electric.co.jp Headquarters & Overseas Sales Office: Jingumae, Shibuya-ku, Tokyo , Japan Tel: , Fax: K-T m3/h Leading company of measuring instruments L/min

2 シリーズ Front Panel Description There are following several problems with previous digital panel meters. 1) The more functions are added, the setting operation became more complicated. 2) Hard to read characters in a 7-segment LED 3) Causes individual differences in the operation including time, such as holding buttons. Watanabe Electric Industry selected a TFT full dot color LCD and cross keys to solve these problems. Also, we developed a totally new digital panel meter with new usage ideas utilizing the full dot LCD to the maximum, while considering people and the environment. Main Features High precision measurements and various measurement menus with a 32-bit MCU. Easy to read by 2.4 inch TFT full-color LCD. The display "values," "bar graphs" and "trend graphs" can be selected according to the measurement application. A display rotation function which can select mounting direction User friendly settings menu and language selection (English and Japanese) Standard 1 channel input type and 2 channel input type which enables special measurements. 1ch Input Type Vertical Display Rotation Function WPMZ Icon List The icons are displayed on the top or bottom of the display. Icons displayed on operation display Displays during the comparator reset function of external control is ON Displays during the max value hold function of external control is ON Icons displayed in settings display (1st layer display) Settings display Comparator output (AL1 to AL4) setting Measurement display setting BCD output setting Icons displayed on settings display (Key operation icons) MENU key Displayed during a key lock Pulse input setting Communication (Modbus, ) setting ENTER key Displays the pattern number currently used Analog input setting setting FUNC key 2ch Input Type (Single phase 2 channel display and calculation, 90 phase input) Display Rotation Function Displayed when the measurement prohibition function of external control is ON Displayed when the current value hold function of external control is ON Displayed when the maximum/minimum value hold function of external control is ON Displayed when the minimum value hold function of external control is ON Displayed in the integrated value over count portion of WPMZ-6 Two input calculation setting External control setting Level display setting Trend display setting Pulse output setting System function setting I/O diagnostics display (Excluding 1st layer level) Displayed while setting protection is ON Cross key (Right) Cross key (Left) Cross keys Cross keys (Up/Down) 1 Digital Panel Meter WPMZ Digital Panel Meter WPMZ 2

3 Innovative The display can be changed to three different methods according to the measurement purpose. Can be identified reliably by any user. WPMZ can select background color (Green/Red/ Yellow) when alarm is ON, which can identify easily by users who have difficulty identifying colors. You can check the status of WPMZ by screen color and icons. Simple Normally displays values, and the unit display can also be selected. The two channel input model consisting of two lines of an Ach and Bch includes a calculation function as standard equipment. Also, calculation formula is displayed. Easy to Use The ratio of the measured value for the entire amount can be seen by the bar graph, and the accurate measurement value can be checked from the numerical display. This function is ideal for the measurement of water levels in tanks. Settings can be performed easily according to the application. Since the measurement trend can be checked in the line graph, the trend of the measurement object can be understood. For example, simple estimation of the life span is possible by understanding the abnormalities of the bearings of rotating objects, and irregular cycles of rotation. Standardly equipped with a function to rotate the panel 90. Horizontal mounting or vertical mounting can be freely selected. For example, the selection of potential mounting spaces will expand even when adding a digital panel which was unexpected during the development of a system. The setting menu can be selected quickly. Simple settings by cross-key operations. The target setting menu can be selected properly, as the settings menu of the WPMZ is displayed in the desired language. This differs greatly from the character information by the conventional 7-segment LED, which eliminates mistakes during the confirmation of the Instructions Manual. Reliable export of systems The WPMZ has language select function.the language can be changed easily between English and Japanese by selecting the language setting menu. Assign a shortcut Restoring setting values Delaying start time Shortcut key of external control function can be assigned to the cross key using "FUNC" key. By holding the cross key down, you can use the external control easily. Environment friendly In addition to the initialize function, WPMZ also can restore the settings to the memorized "set value" set by the customer. Settings can be performed in consideration of the environment. Suppressing power consumption When operation is not performed for a certain period of time, the display can be turned OFF to suppress power consumption. This function can be used as an environmentally friendly function of a system in which the panel is mounted. The start time of a system can be intentionally delayed. For example, sequence errors of overall systems can be prevented by intentionally delaying the time setting in consideration of the warm up of a system where the panel is to be mounted, or the alarm output of the WPMZ which affects the initial activation of a system. Adjusting display brightness The brightness of the WPMZ can be adjusted in five steps (bright to dark). For example, when using at night, unnecessary reflection on windows and peripheral equipment can be prevented. Reliable Prevents accidents. Supports various environments. The power supply can be selected according to the sensor to be connected. Safety can be checked before starting The WPMZ has a built-in self-diagnostics function to prevent accidents with equipment to be connected to the WPMZ. Pre-operation checks can be performed by checking the status of each terminal at once, and outputting a simulated analog output to the connected equipment. Sensor power supply selection Accidents caused by careless operation can be prevented The safety measures of the WPMZ are perfect for careless key operation. Disable the operation of each buttons by pressing the DISP button and the ENTER button at the same time. Various output functions can be selected from RS485 (Modbus), RS232C, Analog, and BCD in the WPMZ. Designated Hazardous- Substance-Free Product 66 Dustproof & Water Resistant Structure IP66 Front bezel 3 Digital Panel Meter WPMZ Digital Panel Meter WPMZ 4

4 Rotation and Speed Measurement -5 Rotation and Speed Measurement -5 WPMZ-5--- Input Ach Input Bch Output Comparator output Rotation and Speed Measurement Note 1 : In case of two input type, the combination of pulse input and line driver input cannot be selected together. Test report Suffix Code voltage: 100 to 240VAC voltage: 12VDC voltage: 24 to 48VDC Pulse input Line driver input N/A Pulse input (Note 1) Line driver input (Note 1) Display only (External control) BCD output (Open collector NPN) BCD output (Open collector PNP) RS-485 (Modbus RTU) Open collector output (NPN) (AL1~AL4) Open collector output (PNP) (AL1~AL4) Without test report With test report Standard Description Pulse input specifications Measurement types: Input frequency range: Input signal: Input level: Input pulse width: Measurement method: Rotation and speed measurement 10mHz to 500kHz * 250kHz for 2 channel input Open collector (NPN/PNP), voltage pulse, totem pole output, AC pulse, proximity sensor Open collector Pull up to 12V or 24V Logic L level: 1.0V or less H level: 3.9 to 30V (Max. allowable voltage ±50V) Zero-crossing 60mV to 40Vac (Max. Allowable voltage 70V) 0.9µs or more (Both L level and H level) *1.8µs or more in case of 2 channel input Cyclic calculation method ±(20ppm reading +1digit) at 23±5 C Open collector output: Output rated NPN sync / PNP source current 50mA max, applied voltage 30Vmax, output saturation voltage 1.2V or less at 50mA Control system: Microcomputer calculation method Judgment value setting range: ± Hysteresis: Can be set within a range from 1 to digits for each judgment value Comparison conditions: Comparison conditions can be set for AL1 to AL4 individually Alarm turns ON when the set value is exceeded (Alarms when value exceeded) Alarm turns ON when the value becomes below the set value (Alarms when value becomes below) specifications Conversion method: D/A conversion method Resolution: 13bit equivalent Scaling: Digital scaling Response speed: 25ms or less (0 90% response) Specifications by types: See below * 4 to 20mA ripple when load resistance is at 250Ω, at 20mA output BCD output specifications Output type: Measurement data: Polarity signal: Print command signal: Transistor capacity: Enable: Open collector output, NPN/PNP type Negative logic; Transistor ON when logic is "1" Transistor ON when negative display Transistor ON for fixed period when data conversion Voltage 30V max, current 10mA max Output transistor turns OFF when the enable terminal is shorted with D.COM RS-485 communication specifications Communication protocol: Modbus RTU Synchronous system: Asynchronous mode Communication method: 2-wire half duplex Communication speed: 9600bps, 19200bps, 38400bps Data length: 8bit Stop bit: 1bit, 2bit Parity bit: N/A, odd number, even number Signal name: Non inverting (+), inverting (-) No. of connectable units: 31 units Line length: 1.2km max (Total) communication specifications Communication protocol: Original protocol Communication method: Full duplex Data length: 7bit, 8bit Character code: ASCII Transmission control procedure: Non-procedura Signal name: TXD, RXD, SGl Line length: 15m Lower terminal (External control, comparator output, power supply) Comparator output, external control * (5), (6), and (7) are connected inside the product. Input (Ach, Bch) Ach pulse input Upper terminal (Input) Bch pulse input External control 1 External control 2 External control 3 External control 4 External control 5 Middle terminal (Optional output) * Select either Ach, Bch or calculation results to be output. RS-485 Ach line driver input P3 P2 P1 Bch line driver input Line Driver Input Specification Measurement types: Input frequency range: Input signal: IInput level: Input pulse width: Rotation and speed measurement 10mHz to 500kHz * 250kHz for 2 channel input Differential input, input resistance () : 330Ω *Can be connected one-to-one with RS-422 compliant line driver device Line driver signal ±1V or more (Differential voltage) 0.9µs or more (Both L level and H level) *1.8µs or more in case of 2 channel input ±(20ppm reading +1digit) at 23±5 C- BCD Compatible wire: AWG#28 flat cable (7/0.127mm) 5 Digital Panel Meter WPMZ Digital Panel Meter WPMZ 6

5 Instantaneous and integrated flow rate -6 Instantaneous and integrated flow rate -6 WPMZ-6--- Input Ach Input Bch Output Comparator output Instantaneous and integrated flow rate Note 1 : In case of two input type, the combination of pulse input and line driver input cannot be selected together. Test report Suffix Code voltage: 100 to 240VAC voltage: 12VDC voltage: 24 to 48VDC Pulse input Analog input N/A Pulse input (Note 1) Analog input (Note 1) Display only (External control) BCD output (Open collector NPN) BCD output (Open collector PNP) RS-485 (Modbus RTU) Open collector output (NPN) (AL1~AL4) Open collector output (PNP) (AL1~AL4) Without test report With test report Standard Description Pulse input (Instantaneous integration) Measurement types: Input frequency range: Input signal: Input level: Input pulse width: Measurement method: Instantaneous integrated measurement 10mHz to 500kHz * 250kHz for 2 channel input Open collector (NPN/PNP), voltage pulse, totem pole output, AC pulse, proximity sensor * In the case of two pulse input, a 2-phase (90º phase) pulse input is available Open collector Pull up to 12V or 24V Logic L level: 1.0V or less H level: 3.9 to 30V (Max. allowable voltage ±50V) Zero-crossing 60mV to 40Vac (Max. Allowable voltage 70V) 0.9µs or more (Both L level and H level) *1.8µs or more in case of 2 channel input Cyclic calculation method Analog input (Instantaneous integration) Conversion method: Input circuit: Sampling rate: Σ conversion method Single-ended type 100 times/second max Open collector output: Output rated NPN sync / PNP source current 50mA max, applied voltage 30Vmax, output saturation voltage 1.2V or less at 50mA Control system: Microcomputer calculation method Judgment value setting range: ± Hysteresis: Can be set within a range from 1 to digits for each judgment value Comparison conditions: Comparison conditions can be set for AL1 to AL4 individually Alarm turns ON when the set value is exceeded (Alarms when value exceeded) Alarm turns ON when the value becomes below the set value (Alarms when value becomes below) specifications Conversion method: D/A conversion method Resolution: 13bit equivalent Scaling: Digital scaling Response speed: 25ms or less (0 90% response) Specifications by types: See below * 4 to 20mA ripple when load resistance is at 250Ω, at 20mA output BCD output specifications Output type: Measurement data: Polarity signal: Print command signal: Transistor capacity: Enable: Open collector output, NPN/PNP type Negative logic; Transistor ON when logic is "1" Transistor ON when negative display Transistor ON for fixed period when data conversion Voltage 30V max, current 10mA max Output transistor turns OFF when the enable terminal is shorted with D.COM RS-485 communication specifications Communication protocol: Modbus RTU Synchronous system: Asynchronous mode Communication method: 2-wire half duplex Communication speed: 9600bps, 19200bps, 38400bps Data length: 8bit Stop bit: 1bit, 2bit Parity bit: N/A, odd number, even number Signal name: Non inverting (+), inverting (-) No. of connectable units: 31 units Line length: 1.2km max (Total) communication specifications Communication protocol: Original protocol Communication method: Full duplex Data length: 7bit, 8bit Character code: ASCII Transmission control procedure: Non-procedura Signal name: TXD, RXD, SGl Line length: 15m Lower terminal (External control, comparator output, power supply) Comparator output, external control * (5), (6), and (7) are connected inside the product. Input (Ach, Bch) Ach pulse input Upper terminal (Input) Bch pulse input External control 1 External control 2 External control 3 P3 P2 P1 External control 4 External control 5 Middle terminal (Optional output) * Select either Ach, Bch or calculation results to be output. RS-485 Ach analog input Bch analog input (Instantaneous display) (Integrated display) Integrated value reset: Pulse output: ±(20ppm reading +1digit) at 23±5 C ±0 (When scaling is "1") Clears integrated value by external control NPN open collector pulse output 30VDC 20mA max BCD Compatible wire: AWG#28 flat cable (7/0.127mm) 7 Digital Panel Meter WPMZ Digital Panel Meter WPMZ 8

6 WPMZ Common Specifications WPMZ List Common specifications Measurement channel: Display: Display range: Zero display: Decimal point: Over range warning: exceeded Operating temp & humidity range: -5 to 50, 35 to 85% RH (No condensation) Storage temp & humidity range: -10 to 70, 60% RH or less : Power consumption: Sensor power supply: Dimensions: Weight: Withstand voltage: Insulation resistance: 1 channel or 2 channels (Based on model selection) 2.4 inch TFT LCD 1ch input: Measurement results of Ach input 2 ch input: Either measurement results of Ach input, measurement results of Bch input, or calculation results Measurement results of Ach and Bch input Measurement results and calculation results of Ach or Bch input ± Leading zero suppression Arbitrary setting possible OVER or -Over when input range and display range are 100 to 240VAC ±10% 50/60 Hz 12VDC ±10% 24 to 48VDC ±10% 10VA max. at 100VAC 14VA max. at 240VAC 6W max. at 12VDC 6W max. at 24VDC 6.5W max. at 48VDC 12VDC ±10% 100mA max; 24VDC ±10% 50mA max *When 2 channel input, allowable current of Ach and Bch together will be above current. *1.2W max. when the combination of 12VDC and 24VDC (For example: Ach is 12V and Bch is 24V) (Line driver input) 5VDC ±10% 200mA max. *When 2 channel input, allowable current of Ach and Bch together will be above current. 96mm(W) x 48mm(H) x 145mm(D), 1/8 DIN size Approx. 350g AC power supply 3000VAC for 1 minute: Between the power supply terminal - input / external control / comparator output / option output DC power supply 1500VAC for 1 minute: Between the power supply terminal - input / external control / comparator output / option output AC/DC power supply 1500VAC for 1 minute: Between the input terminal - external control / comparator output / option output 500VDC 100MΩ or more between the above terminals Vibration resistance: Protection: Installation location: Rated altitude: Overvoltage: Measurement category: Contamination level: Applicable EN standard: Case material / color: External control 10 to 55Hz; 0.15mm single amplitude in X, Y and Z directions for 30 minutes IP66 (Front bezel) Indoors 2000m or less Comparator reset: Shorted with COM terminal, turns OFF comparator output monitor and comparator output Measurement prohibited: Shorted with COM terminal, prohibits measurement and integration Measurement prohibited A: Valid for Ach; Measurement prohibited B: Valid for Bch Measurement prohibited A & B: Valid for Ach and Bch simultaneously Current value hold: Shorted with COM terminal, holds the display value Current value hold A: Valid for Ach; Current value hold B: Valid for Bch Current value hold A & B: Valid for Ach and Bch simultaneously Max value hold: Shorted with COM terminal, holds the max value Max value hold A: Valid for Ach; Max value hold B: Valid for Bch Max value hold A & B: Effective for Ach and Bch simultaneously Min value hold: Shorted with COM terminal, holds the min value Min value hold A: Valid for Ach; Min value hold B: Valid for Bch Min value hold A & B: Effective for Ach and Bch simultaneously Display change: Shorted with COM terminal, changes the measurement display Pattern change 1 to 3: Shorted with COM terminal, changes the pattern used for measurement Trend hold: Shorted with COM terminal, holds the trend display Integrated value reset: Shorted with COM terminal, reset the integrated value The model can be selected from a 1 channel or 2 channel input specification for this digital panel meter, equipped with a comparator and various calculation functions. In the 2 channel specification model, the measured value and calculated value including the Ach + Bch, etc. can be displayed for the Ach (1 channel) and Bch (2 channels) respectively This unit compares the display value, and the comparison results can be output by the open collector (NPN, PNP). Optional analog output, RS-485,, and BCD are also available. Dimensions (1/8 DIN size) Digital Panel Meter WPMZ Digital Panel Meter WPMZ 10

DIGITAL INDICATING CONTROLLER

DIGITAL INDICATING CONTROLLER DB1000 SERIES DIGITAL INDICATING CONTROLLER The DB1000 series is a 96 96mm digital indicating controller with the indicating accuracy of ±0.1% and the control cycle of approximately 0.1 seconds. Various

More information

LAUREL. Laureate Rate Meter & Totalizer with Functions A+B, A-B, AxB, A/B, A/B-1 ELECTRONICS, INC. Features. Description

LAUREL. Laureate Rate Meter & Totalizer with Functions A+B, A-B, AxB, A/B, A/B-1 ELECTRONICS, INC. Features. Description Description LAUREL ELECTRONICS, INC. Features Laureate Rate Meter & Totalizer with Functions A+B, A-B, AxB, A/B, A/B-1 Arithmetic functions A+B, A-B, AxB, A/B, A/B-1 applied to rate or total for channels

More information

Process displays For current and voltage

Process displays For current and voltage Features Voltage input TRMS-AC/DC up to 600 V Current input AC/DC 1 A, 5 A and shunt (precision resistor) 60 or 100 mv With 2 or 4 limits Display range can be linearised Min, Max, Hold functions 4 20 ma

More information

LAUREL. Laureate Pulse or Analog Input Batch Controller Automatic batch control for repetitive liquid fill operations ELECTRONICS, INC.

LAUREL. Laureate Pulse or Analog Input Batch Controller Automatic batch control for repetitive liquid fill operations ELECTRONICS, INC. Description LAUREL ELECTRONICS, INC. Laureate Pulse or Analog Input Batch Controller Automatic batch control for repetitive liquid fill operations Features Available for turbine flow meter pulse signals

More information

Programmable Relay ZEN V2 Units

Programmable Relay ZEN V2 Units Programmable Relay ZEN V2 Units Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Refer to Warranty

More information

LAUREL. Laureate Dual-Channel Pulse Input Totalizer With Two Independently Scalable Input Channels & Presets ELECTRONICS, INC. Features.

LAUREL. Laureate Dual-Channel Pulse Input Totalizer With Two Independently Scalable Input Channels & Presets ELECTRONICS, INC. Features. Description LAUREL ELECTRONICS, INC. Laureate Dual-Channel Pulse Input Totalizer With Two Independently Scalable Input Channels & Presets Features Frequencies up to 1 MHz Totals stored in non-volatile

More information

E4PA. Ultrasonic Displacement Sensor. Ordering Information

E4PA. Ultrasonic Displacement Sensor. Ordering Information Ultrasonic Displacement Sensor Ideal for controlling liquid level. Long sensing distance and high-resolution analog output. High-precision detection with a wide range of measurements Four types of Sensors

More information

Amplifiers, Counters, Timers & Controls

Amplifiers, Counters, Timers & Controls Amplifiers, Counters, Timers & Controls Panel Meter 814 Counter/Timer/Rate Indicator 815-817 Speed Monitor 818-819 Signal Converter 820-822 Power Supplies/Amplifier 823-824 813 Panel Meter Panel Meter

More information

LAUREL ELECTRONICS, INC.

LAUREL ELECTRONICS, INC. Description LAUREL ELECTRONICS, INC. Laureate Pulse or Analog Input Batch Controller Automatic batch control for repetitive liquid fill operations Features Available for turbine flow meter pulse signals

More information

Batch Controller with numerical keypad, remote control inputs and 3 control / alarm / pulse outputs

Batch Controller with numerical keypad, remote control inputs and 3 control / alarm / pulse outputs Datasheet N410 User-friendly batch controller Reliable Batch Controller with numerical keypad, remote control inputs and 3 control / alarm / pulse outputs Advantages Save time and cost with the easy to

More information

Y800 Plus Frequency, Rate & Period Meter With dual, independently field-scalable channels

Y800 Plus Frequency, Rate & Period Meter With dual, independently field-scalable channels Y800 Plus Frequency, Rate & Period Meter With dual, independently field-scalable channels Description Features Frequencies from 0.005 Hz to 1 MHz 6-digit resolution at update rates up to 25/s Selectable

More information

LASER. Laser Displacement Transducer. Series LAH-G1. Key-Features:

LASER. Laser Displacement Transducer. Series LAH-G1. Key-Features: LASER Laser Displacement Transducer Series LAH-G1 Key-Features: Content: Technical Data...2 Technical Drawing...3 Electrical Connection...4 Order Code...5 ranges up to 300 mm Resolution up to 0.5 μm Protection

More information

H3CA-8H-AC/100/110/120

H3CA-8H-AC/100/110/120 Solid-State Timer 1/16 DIN, Digital-Set Timer with 0.1 Second to 9,990 Hours Range 8 field-selectable operation modes Universal AC/DC supply voltage timers available Operations include ON-delay, Repeat

More information

Paperless Recorder VGR-B100. Series

Paperless Recorder VGR-B100. Series Paperless Recorder VGR-B100 Series CE marking RoHS compliant Easy-to-Use! Paperless Recorder with Touch Screen VGR-B100 Easy Operation! Touch Screen Operation User friendly interface through a 5.7 inch

More information

Multifunction Transducer MT440

Multifunction Transducer MT440 Multifunction Transducer MT440 Voltage and current auto range measurements up to 600V, 12.5A Universal wide auxiliary power supply range 24 300 Vdc, 40 276 Vac Power accuracy class 0.5 (EN 60 688), Up

More information

MODEL: 40DN. Digital Panel Meters 40 Series

MODEL: 40DN. Digital Panel Meters 40 Series Digital Panel Meters 40 Series LOOP POWERED DIGITAL PANEL METER (4 digits, process meter) Functions & Features 4 digit (±9999) loop powered panel meter No external power source needed Scaling function

More information

Features and Benefits. Certifications

Features and Benefits. Certifications iologik R1200 Series RS-485 remote I/O Features and Benefits Dual RS-485 remote I/O with built-in repeater Supports the installation of multidrop communications parameters Install communications parameters

More information

Energy Management Modular DC Energy analyzer Type VMU-E and VMU-X

Energy Management Modular DC Energy analyzer Type VMU-E and VMU-X Energy Management Modular DC Energy analyzer Type VMU-E and VMU-X Modular solution based on the combination of two units: VMU-E analysis unit and VMU-X universal power supply and RS485 communication unit.

More information

Digital Indicator Solutions

Digital Indicator Solutions Digital Indicator Solutions Loop-Powered Attachable Compact Attachable Loop-Powered Smart Compact System Loop-Powered Compact Smart System Intelligent Smart System "Intelligent" Options Dual & Display

More information

Temperature/Process Meter

Temperature/Process Meter Temperature/Process Meter High-Performance Temperature Meter Accepts Temperature/Analog Inputs Multi-range capability: a single processor connects 14 types of sensors with varying current/voltage Programmable

More information

KRAL Electronics BEM 300 and BEM 500.

KRAL Electronics BEM 300 and BEM 500. KRAL Electronics BEM 300 and BEM 500. KRAL Electronics BEM 300 and BEM 500 Electronic units that are coordinated to KRAL flowmeters and their diverse applications. Coordinated to the flowmeters and their

More information

LAUREL. MAGNA Series Large Digit Displays for Counter / Totalizer Pulse Input ELECTRONICS, INC. Features. Description

LAUREL. MAGNA Series Large Digit Displays for Counter / Totalizer Pulse Input ELECTRONICS, INC. Features. Description LAUREL ELECTRONICS, INC. MAGNA Series Large Digit Displays for Counter / Totalizer Pulse Input Features Choice of 2-1/4", 4", 6" or 8" digit heights Choice of 4 or 6 digits with decimal points Choice of

More information

Electronic Preset Counter with 2 Presets and Print interface. NE213 Prog Features

Electronic Preset Counter with 2 Presets and Print interface. NE213 Prog Features Electronic Preset Counter with 2 Presets and Print interface NE21 Prog. 09 Features Order designation Order no. Interface RS22 Models Connection Functions LED-preset counter with 2 presets Batch counter

More information

DINALOG A 144 x 36 A1400 Light-Strip Indicator

DINALOG A 144 x 36 A1400 Light-Strip Indicator DINALOG A x 6 A00 Light-Strip Indicator -9-0-0 /.00 Front panel dimensions: x 6 mm Light-strip indicator with 7 high-contrast LEDs Red LED display color Digital display range for portrait format: 999 to

More information

LBVR1718. Description. Features channel paperless recorder

LBVR1718. Description. Features channel paperless recorder LBVR1718 18 - channel paperless recorder Description It is the world first paperless recorder of the same size in highest resolution 640x480 pixels VGA TFT display, infrared detector, maximum 18 channels,

More information

Ferrous metal (The sensing distance decreases with non-ferrous metal.) Power supply voltage (operating voltage range)

Ferrous metal (The sensing distance decreases with non-ferrous metal.) Power supply voltage (operating voltage range) Description The sensors provide excellent results even with difficult-to-detect objects, e.g. small or thin parts, wires or bright metals. A variety of types cover a wide range of individual requirements

More information

Remote I/O Modules EH-RIO2 Series

Remote I/O Modules EH-RIO2 Series Remote I/O Modules EH-RIO2 Series Fieldbus adapter: ProfiNET, EtherCAT, Modubus TCP / RTU, Profibus-DP, DeviceNet Separation of electronics module and terminal block for easy installation and maintenance

More information

OTB1S0DM9LP I/O distributed module OTB - Modbus non isolated serial link m

OTB1S0DM9LP I/O distributed module OTB - Modbus non isolated serial link m Characteristics I/O distributed module OTB - Modbus non isolated serial link - 0..10 m Complementary Topology Bus length Main Number of devices per segment 0...32 Data format Parity Discrete input voltage

More information

1.6. Counters, Panel Meters, Tachometers and Timers. Contents Description Fusion Integrated Machine Control Standards and Certifications...

1.6. Counters, Panel Meters, Tachometers and Timers. Contents Description Fusion Integrated Machine Control Standards and Certifications... .6 Contents Standards and Certifications............... Product Selection....................... Technical Data and Specifications........... Dimensions............................ Learn Online Page V3-T-04

More information

Tachometers TC-4B-V TC-6A-V Electronic cam-operated switching devices FC-21-V... 50

Tachometers TC-4B-V TC-6A-V Electronic cam-operated switching devices FC-21-V... 50 List of content page Counters and indicators DA5-IU-C... 10 DA5-IU-2K-C... 12 DA5-IU-2K-V... 12 KCM-51-C... 14 KCM-51-V... 14 KCM-70-C... 16 KCM-70-V... 16 KCM-70A-C... 18 KCM-70A-V... 18 KCT-6S-C... 20

More information

Model Number Structure

Model Number Structure Total Counter/Time Counter (DIN 8 x ) CSM DS_E DIN 8 x -mm Total Counter/Time Counter with Easy-to-read Displays and Water and Oil Resistance Equivalent to IP66 High-visibility, negative transmissive LCD

More information

AD-8923-BCD. Remote Controller (BCD) INSTRUCTION MANUAL 1WMPD

AD-8923-BCD. Remote Controller (BCD) INSTRUCTION MANUAL 1WMPD AD-8923-BCD Remote Controller (BCD) INSTRUCTION MANUAL 1WMPD4002137 2010 A&D Company, Limited. All rights reserved. No part of this publication may be reproduced, transmitted, transcribed, or translated

More information

RS-485 I/O Modules: ADAM-4000

RS-485 I/O Modules: ADAM-4000 RS-485 I/O Modules: ADAM-4000 23 ADAM-4000 Series Overview ADAM-4000 Series Remote Data Acquisition and Control Modules Overview 23-2 and Controller Module Selection Guide 23-4 I/O Module Selection Guide

More information

H7BX CSM_H7BX_DS_E_4_4

H7BX CSM_H7BX_DS_E_4_4 Multifunction Counter (DIN 72 72) H7BX CSM_H7BX_DS_E_4_4 DIN 72 72 mm Multifunction Counter with a Bright, Easy-to-view, Negative Transmissive LCD. Highly visible display with backlit transmissive LCD.

More information

SX 6000 Paperless Recorder

SX 6000 Paperless Recorder SILVER AUTOMATION INSTRUMENTS HTTP://WWW.SILVERINSTRUMENTS.COM RUNYI GROUP SX 6000 Paperless Recorder Product Overview SX6000 Paperless Recorder color-screen paperless recorder has 16-channel universal

More information

Programmable Relay ZEN V2 Units

Programmable Relay ZEN V2 Units Programmable Relay ZEN V2 Units Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Refer to Warranty

More information

Cylindrical Proximity Sensor

Cylindrical Proximity Sensor Cylindrical Proximity Sensor A New Series of Easy-to-use and Tough Models with a Yellow Indicator New series of TL-X2C1-GE models with improved performance over the previous TL-X-E models. Also, in addition

More information

3-step setting 2. 2-Color Display High-Precision Digital Pressure Switch. ZSE30A(F)/ISE30A Series. Added vacuum range.

3-step setting 2. 2-Color Display High-Precision Digital Pressure Switch. ZSE30A(F)/ISE30A Series. Added vacuum range. 2-Color Display High-Precision Digital Pressure Switch ZSE3A(F)/E3A Series RoHS Can copy to up to 1 switches simultaneously. setting labor Minimizing ZSE3 E3 ZSE4 E4 The settings of the master sensor can

More information

Clear Benefits of the KRAL Electronic.

Clear Benefits of the KRAL Electronic. Clear Benefits of the KRAL Electronic. Coordinated to the flowmeters and their applications. Users of conventional universal display units often cannot make use of their device s options. There is often

More information

Display and Monitoing Units

Display and Monitoing Units Display and Monitoing Units DISPLAY AND MONITOrING UNITS 13 The universal display unit HDA 5500 provides the means of visualizing and further processing the signals from our sensors. The unit is designed

More information

E3S-A. Built-in Amplifier Photoelectric Sensor (Medium Size) Ordering Information. Built-in Amplifier Photoelectric Sensors. Horizontal. 7 m.

E3S-A. Built-in Amplifier Photoelectric Sensor (Medium Size) Ordering Information. Built-in Amplifier Photoelectric Sensors. Horizontal. 7 m. Built-in Amplifier (Medium Size) ES-A Be sure to read Safety Precautions on page 0. Ordering Information Built-in Amplifier s Red light Infrared light Sensing method Appearance Connection method Sensing

More information

TRACKER 240 SERIES. Load Cell and Weighing Indicators. A Precision Measurement Instrument with Outstanding Features

TRACKER 240 SERIES. Load Cell and Weighing Indicators. A Precision Measurement Instrument with Outstanding Features TRACKER 240 SERIES Load Cell and Weighing Indicators A Precision Measurement Instrument with Outstanding Features TRACKER 240 SERIES INDICATORS Ratiometric Measurement Tare and Auto Transducer Excitation

More information

Data Sheet T 6493 EN. TROVIS 6400 Automation System TROVIS 6493 Compact Controller. For panel mounting (front frame 48 x 96 mm/1.89 x 3.

Data Sheet T 6493 EN. TROVIS 6400 Automation System TROVIS 6493 Compact Controller. For panel mounting (front frame 48 x 96 mm/1.89 x 3. Data Sheet T 6493 EN TROVIS 6400 Automation System TROVIS 6493 Compact Controller For panel mounting (front frame 48 x 96 mm/1.89 x 3.78 inch) Application Digital controller to automate industrial and

More information

Monitoring Relays can be used to monitor 3-phase power supplies with 3 or 4 wires simply by changing DIP switch settings.

Monitoring Relays can be used to monitor 3-phase power supplies with 3 or 4 wires simply by changing DIP switch settings. Authorised Distributors:- Intech Systems Chennai Pvt. Ltd, Chennai-600 032 Ph: +91 44 4353 8888 Fax: 044 4353 7888 E-mail: info@intechchennai.com Website: www.intechchennai.com Three-phase Voltage Relay

More information

V E1B Snap-in I/O Module

V E1B Snap-in I/O Module V200-18-E1B Snap-in I/O Module The V200-18-E1B plugs directly into the back of compatible Unitronics OPLCs, creating a selfcontained PLC unit with a local I/O configuration. Features 16 isolated digital

More information

Power Supply Input voltage 20.4VDC to 28.8VDC with less than 10% ripple Max. current consumption See Note 1

Power Supply Input voltage 20.4VDC to 28.8VDC with less than 10% ripple Max. current consumption See Note 1 Vision OPLC V350-35-TRA22 Technical Specifications The Unitronics V350-35-TRA22 offers the following onboard I/Os: 12 Digital Inputs, configurable via wiring to include 2 Analog, 2 PT100/TC and 1 HSC/Shaftencoder

More information

MIC-2 MKII, Multi-instrument DATA SHEET

MIC-2 MKII, Multi-instrument DATA SHEET MIC-2 MKII, Multi-instrument DATA SHEET Measurements All 3-phase AC measurements True RMS 4-Quadrant energy Power Quality Analysis Replaces analogue meters RS-485 Modbus RTU protocol TCP/IP Modbus (optional)

More information

Making Hazardous Operations Safe and Productive

Making Hazardous Operations Safe and Productive NEW Safety Guard Switching Unit G9SX-GS Making Hazardous Operations Safe and Productive Making Hazardous Operations Safe and Productive This new addition to the model of Flexible Safety Unit G9SX series

More information

2. Actuator B: Ball type P: Pin type F: Flat type

2. Actuator B: Ball type P: Pin type F: Flat type Contact Displacement Sensor Built-in Amplifier Ensures Ease of Use and Saves Wiring Effort. Sensor Operates with a Low Force in a Wide Range of Applications. H Works with a low operating force (30 gf)

More information

Note: Each relay to be mounted must incorporate a coil that has proper specifications within the maximum rated voltage range.

Note: Each relay to be mounted must incorporate a coil that has proper specifications within the maximum rated voltage range. I/O Block Base G7A Reduces Wiring while Providing I/O Flexibility Mount I/O relays and I/O SSRs freely. Electric-shock preventive (finger-touch protection) terminal block incorporated conforming to VDE

More information

Installation Instructions for the ISSUE 3 RDS-DIN1 Series Single Channel Interface Module PK 80103

Installation Instructions for the ISSUE 3 RDS-DIN1 Series Single Channel Interface Module PK 80103 Installation Instructions for the ISSUE 3 RDS-DIN1 Series Single Channel Interface Module PK 80103 PERSONAL INJURY DO NOT USE in applications where product failure could result in personal injury or death.

More information

Samba PLC+HMI SM35-J-RA22

Samba PLC+HMI SM35-J-RA22 Samba PLC+HMI SM35-J-RA22 SM43-J-RA22 Technical Specifications Ordering Information Item SM35-J-RA22 PLC with Flat panel, Color touch display 3.5 SM43-J-RA22 PLC with Flat panel, Color touch display 4.3

More information

PRODIS. PD-ADC Digital Process Meter for analog Sensors. Digital Process Meters. Datasheet

PRODIS. PD-ADC Digital Process Meter for analog Sensors. Digital Process Meters. Datasheet Digital Process Meters Digital Process Meter for analog Sensors Datasheet Copyright ASM GmbH Am Bleichbach 18-24 85452 Moosinning Germany The information presented in this data sheet does not form part

More information

MODEL: R1M-A1. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)

MODEL: R1M-A1. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.) PC Recorders R1M Series PC RECORDER (contact input, 32 points) Functions & Features Industrial recorder on PC 32-point dry contact inputs Easy system expansion via Modbus RTU Recorded data exportable to

More information

OTB1S0DM9LP I/O distributed module OTB - Modbus non isolated serial link m

OTB1S0DM9LP I/O distributed module OTB - Modbus non isolated serial link m Characteristics I/O distributed module OTB - Modbus non isolated serial link - 0..10 m Product availability : Stock - Normally stocked in distribution facility Price* : 494.00 USD Main Range of product

More information

Inductive Proximity Sensor

Inductive Proximity Sensor Inductive Proximity Sensor Miniature, Slim-styled Proximity Sensor Space-saving Sensor ideal for timing cam and dog detection. Four mounting holes provided: two each mounting from side or rear of the housing.

More information

WSK INTELLIGENT TEMPERATURE AND HUMIDITY CONTROLLER USER MANUAL

WSK INTELLIGENT TEMPERATURE AND HUMIDITY CONTROLLER USER MANUAL WSK INTELLIGENT TEMPERATURE AND HUMIDITY CONTROLLER USER MANUAL WSK INTELLIGENT TEMPERATURE AND HUMIDITY CONTROLLER USER MANUAL v 1.0 Thanks for choosing the Intelligent temperature and humidity controller

More information

02/11/2015

02/11/2015 DIN Rail Mount 35 mm HSV Part number 84874320 Control of overspeed, underspeed, operating rate, stopping Measurement via discrete sensors - 3-wire PNP or NPN, Namur, voltage 0-30V or volt-free contact

More information

RS 485 Mini Modbus 1AO

RS 485 Mini Modbus 1AO RS 485 Mini Modbus 1AO Version 1.0 14/08/2014 Manufactured for Thank you for choosing our product. This manual will help you with proper support and proper operation of the device. The information contained

More information

MODEL: R1M-P4. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)

MODEL: R1M-P4. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.) PC Recorders Series PC RECORDER (4 totalized counter inputs, 8 contact inputs and outputs) Functions & Features Industrial recorder on PC Totalized counter inputs Counts stored in E 2 PROM Easy system

More information

Dupline. Data Logger. Types G , G Product Description. Ordering Key G Type Selection. Input/Output Specifications

Dupline. Data Logger. Types G , G Product Description. Ordering Key G Type Selection. Input/Output Specifications Dupline Data Logger Types G 800 006, G 800 106 Product Description Programmable channel generator with optional built-in GSM Modem Event and time based data logging functions for digital, analog and counter

More information

R1M-GH THERMOCOUPLE & DC INPUT MODULE MODEL. Remote I/O R1M Series. (16 points)

R1M-GH THERMOCOUPLE & DC INPUT MODULE MODEL. Remote I/O R1M Series. (16 points) Remote I/O R1M Series THERMOCOUPLE & DC INPUT MODULE (16 points) MODEL MODEL & SUFFIX CODE SELECTION R1MGH2T MODEL Modbus protocol I/O TYPE GH2 : Thermocouple or DC input, 16 points FIELD TERMINAL TYPE

More information

Item SM35-J-TA22 SM43-J-TA22 SM70-J-TA22

Item SM35-J-TA22 SM43-J-TA22 SM70-J-TA22 Samba PLC+HMI SM35-J-TA22 SM43-J-TA22 SM70-J-TA22 Technical Specifications Ordering Information Item SM35-J- TA22 PLC with Flat panel, Color touch display 3.5 SM43-J- TA22 PLC with Flat panel, Color touch

More information

V E2B Snap-in I/O Module

V E2B Snap-in I/O Module V200-18-E2B Snap-in I/O Module The V200-18-E2B plugs directly into the back of compatible Unitronics OPLCs, creating a selfcontained PLC unit with a local I/O configuration. Features 16 isolated digital

More information

General Specifications

General Specifications General Model I/O Module (for N-IO) GS 32P06K30-01EN GENERAL This General (GS) provides the hardware specifications of I/O module (for N-IO) that can be mounted on the Base Plate for N-IO I/O (S2BN1D,

More information

Oil-resistive, Long-range Photoelectric Sensor with Metal Housing

Oil-resistive, Long-range Photoelectric Sensor with Metal Housing Oil-resistive, Long-range with Metal Housing ES-C Water- and Oil-resistive with Metal Housing Used for Long-range Sensing Satisfies the water- and oil-resistive requirements and safe enough for use in

More information

Universal counter UZ 9648 Counting - length measurement - metering - positioning

Universal counter UZ 9648 Counting - length measurement - metering - positioning +49-(0)40-670 73-0 Fax +49-(0)40-670 73-288 info@martens-elektronik.de www.ghm-messtechnik.de Universal counter UZ 9648 Counting - length measurement - metering - positioning Features M LED-Display 14.2mm

More information

Energy Management Modular DC Energy analyzer Type VIM-E and VIM-X

Energy Management Modular DC Energy analyzer Type VIM-E and VIM-X Energy Management Modular DC Energy analyzer Type VIM-E and VIM-X Modular solution based on the combination of two units: VIM-E analysis unit and VIM-X universal power supply and RS485 communication unit.

More information

User safety and equipment protection guidelines

User safety and equipment protection guidelines Snap-in I/O Module The V200-18-E1 plugs directly into the back of compatible Unitronics OPLCs, creating a selfcontained PLC unit with a local I/O configuration. The module offers: 3 analog inputs 16 digital

More information

10 DIGITAL MICRO-PROCESS TOTALIZER METER with ALARMS / ANALOG OUTPUT / PULSE OUTPUT / RS-485. T Total Alarm x 1 + FRONT PANEL & KEY FUNCTIONS

10 DIGITAL MICRO-PROCESS TOTALIZER METER with ALARMS / ANALOG OUTPUT / PULSE OUTPUT / RS-485. T Total Alarm x 1 + FRONT PANEL & KEY FUNCTIONS 0 DIGITAL MICRO-PROCESS TOTALIZER METER with ALARMS / ANALOG OUTPUT / PULSE OUTPUT / RS-85 + FEATURES! Accuracy: + - 0.00% F.S. High brightness 0." LED; Rate of display range: 0~99999 Rate / Total decimal

More information

D1000M SERIES FOR MODBUS SENSOR TO COMPUTER INTERFACE MODULES

D1000M SERIES FOR MODBUS SENSOR TO COMPUTER INTERFACE MODULES D1000M SERIES FOR MODBUS SENSOR TO COMPUTER INTERFACE MODULES D1000 FEATURES Complete sensor to RS-232/RS-485 interface. 500V rms analog input isolation. 15 bit measurement resolution. Continuous self-calibration;

More information

Energy Management Modular Universal Utility Meter and Power Analyzer Type WM24-96

Energy Management Modular Universal Utility Meter and Power Analyzer Type WM24-96 Energy Management Modular Universal Utility Meter and Power Analyzer Type WM24-96 Class 1 (active energy) Class 2 (reactive energy) Accuracy 0.5% RDG (current/voltage) Universal utility meter and power

More information

KTC. Preset Counter/ Timer. Programmable Type. Model Number Legend SALIENT FEATURES. Sensing. Digital Panel Meters

KTC. Preset Counter/ Timer. Programmable Type. Model Number Legend SALIENT FEATURES. Sensing. Digital Panel Meters Preset Counter/ Timer Programmable Type Model Number Legend SALIENT FEATURES 6 Digits PV, SV Universal Input Dual alarm output MODBUS via RS-485 High Speed - 10 KCPS Multiple output modes Batch Counting,

More information

Displays Transducers. Displays and transducers

Displays Transducers. Displays and transducers JJ Displays JJ Transducers Displays and transducers DS_Displays_and_transducers 06/2016 225 Displays and transducers Our electronic devices for flow and volume measurement are suitable for all SIKA flow

More information

DIGITAL DISPLAY. for Industry Applications. Series WAY-SSI. Key-Features:

DIGITAL DISPLAY. for Industry Applications. Series WAY-SSI. Key-Features: DIGITAL DISPLAY for Industry Applications Series WAY-SSI Key-Features: Content: Technical Data.2 Technical Drawing...2 Electrical Connection...3 Description...4 Order Code & Accessories...6 - WAY-SSI-S:

More information

PROGRAMMABLE CONTROLLER. FP0 A/D Converter Unit. Technical Manual ARCT1F321E

PROGRAMMABLE CONTROLLER. FP0 A/D Converter Unit. Technical Manual ARCT1F321E PROGRAMMABLE CONTROLLER Technical Manual ARCT1F321E-2 2008.11 Safety Precautions Observe the following notices to ensure personal safety or to prevent accidents. To ensure that you use this product correctly,

More information

EtherCAT Remote I/O Terminal GX series

EtherCAT Remote I/O Terminal GX series EtherCAT Remote I/O Terminal GX series Digital I/O Terminal 2-tier Terminal Block Type Digital I/O Terminal 3-tier Terminal Block Type Digital I/O Terminal e-con Connector Type Analog I/O Terminal 2-tier

More information

Inductive Proximity Sensor

Inductive Proximity Sensor Inductive Proximity Sensor Subminiature Sensor with Cable Amplifier Offers Greater Mounting Flexibility Programmable Controller-compatible Subminiature, shielded sensing head (3 or 8 dia.) allows the Sensor

More information

Self-Powered Counters H7EC

Self-Powered Counters H7EC Self-Powered Counters Subminiature Count Totalizers Require No External Power Supply Subminiature 8 x mm (1.89 x.9 in) Improved noise immunity Screw terminal and wire-wrap types available AC, DC, and no-voltage

More information

Panel Indicators. NEW 4~20mA Panel Display. Process Indicators INTECH INSTRUMENTS.

Panel Indicators. NEW 4~20mA Panel Display. Process Indicators INTECH INSTRUMENTS. The LPI-LCD-6-4~20mA panel display is ideal for displaying a variety of process variables, and is easy to scale to your required engineering units. LPI-LCD-6 4~20mA Panel Display. Loop powered. Loop powered

More information

MPI-DN, MPI-D MULTICHANNEL ELECTRONIC RECORDER for HART or RS-485/ MODBUS RTU SENSORS

MPI-DN, MPI-D MULTICHANNEL ELECTRONIC RECORDER for HART or RS-485/ MODBUS RTU SENSORS MPI-DN, MPI-D MULTICHANNEL ELECTRONIC RECORDER for HART or RS-485/ MODBUS RTU SENSORS 18 channels for HART / Modbus RTU sensors 2 digital channels 16 math channels 4 relay outputs for alarm or control

More information

Optimum sensing capability for LCD manufacturing

Optimum sensing capability for LCD manufacturing SENSORS FOR Glass Substrate Detection Sensor Amplifier-separated FX-301-F FT-F9 FD-F7 EX-F70/F60 HD-T1 M FD-L3 Reliable detection of glass substrates Its unique optical system enables detection of transparent

More information

1 open / 1 close, 240 V ac / 2 A. < 70 ma < 65 ma ac 20 Hz 13 Hz dc 72 Hz 25 Hz

1 open / 1 close, 240 V ac / 2 A. < 70 ma < 65 ma ac 20 Hz 13 Hz dc 72 Hz 25 Hz Description Operation mode and max sensing range: Diffuse proximity: 0-5 m Background suppression: 0- m Compact rectangular housing (x mm) Cable or rotatable plug connection via potentiometer Switch selectable

More information

All Analog Outputs, voltage/current 10mA 35mA 5mA 48mA/30mA* *If the analog outputs are not configured, then subtract the higher value.

All Analog Outputs, voltage/current 10mA 35mA 5mA 48mA/30mA* *If the analog outputs are not configured, then subtract the higher value. Vision OPLC V350-35-TRA22/V350-J-TRA22 Technical Specifications The Unitronics V350-35-TRA22/V350-J-TRA22 offers the following onboard I/Os: 12 Digital Inputs, configurable via wiring to include 2 Analog,

More information

Measuring and Monitoring Relays

Measuring and Monitoring Relays Measuring and Monitoring Relays K8AB Series/61F-D21T Industry First! Two SPDT Outputs Available in New Models DIN Sized at 22.5 mm Seven slim models featuring a variety of innovative new functions. Single-phase

More information

GL200A midi Logger. Wide Sample Interval Selections Sample intervals can be programmed to be one of sixteen values ranging from 100 ms to one hour.

GL200A midi Logger. Wide Sample Interval Selections Sample intervals can be programmed to be one of sixteen values ranging from 100 ms to one hour. GL200A midi Logger Built-in 3.5" TFT LCD Color Display Stand-alone or PCconnected operation 10 Analog Channels Input-to-output & channel-to-channel Isolation USB PC Interface With its color monitor and

More information

E3X-NA. Adjuster type standard that is the culmination of true ease and simplicity. Super Manual Fiber Amplifier. Features

E3X-NA. Adjuster type standard that is the culmination of true ease and simplicity. Super Manual Fiber Amplifier. Features Super Manual Fiber Amplifier Adjuster type standard that is the culmination of true ease and simplicity Features Self-explanatory LED bar displays of light levels The previous manual type used the stability

More information

UNIVERSAL CURRENT CONVERTER

UNIVERSAL CURRENT CONVERTER UNIVERSAL CURRENT / VOLTAGE CONVERTER AC/DC Current / Voltage Analyzer The is the first CURRENT / VOLTAGE CONVERTER & ANALYZER ALL IN ONE - of the market. It allow you to connect all isolated current sensors.

More information

Modbus Digital Remote I/O. ARM Series. Modbus Sensor Connector Type Digital Remote I/O. Features. User Manual For Communication. Ordering Information

Modbus Digital Remote I/O. ARM Series. Modbus Sensor Connector Type Digital Remote I/O. Features. User Manual For Communication. Ordering Information RM Series Modbus Digital Remote I/O Modbus Connector Type Digital Remote I/O Features Modbus RTU standard protocol Connects with sensor connector, e-con: saves wiring work (sensor connector, CNE Series,

More information

Safety: UL508 EMC: CE IEC , IEC Vibration: IEC (2 g s during operation) Warranty

Safety: UL508 EMC: CE IEC , IEC Vibration: IEC (2 g s during operation) Warranty NA-4020/4021 RS-485 or RS-232 network adaptors ioogik 4000 Modbus RS-485 NA-4020 SYS TxD RxD I/O Field Power CH0 24V 0V SG SG System Power (0 VDC) System Power (24 VDC) Shielding Ground Non-isolation Switching

More information

Product Discontinuation Notices. Discontinuation Notice of Compact proximity sensor TL-M series (for china area only)

Product Discontinuation Notices. Discontinuation Notice of Compact proximity sensor TL-M series (for china area only) PRODUCT NEWS Product Discontinuation Notices August 1, 2011 Proximity Sensors No. 2011248E-2 Discontinuation Notice of Compact proximity sensor (for china area only) Product Discontinuation Recommended

More information

SORDS ELECTRIC ~ MA7200. Sensorless Vector AC Inverter.

SORDS ELECTRIC ~ MA7200. Sensorless Vector AC Inverter. www.sordselectric.com MA7200 Sensorless Vector AC Inverter Features and Benefits Sensorless Vector The MA7200 has precise speed and torque control for the most demanding system performance and simple set-up

More information

PM174 PM174 IEEE1159 ADVANCED POWER QUALITY ANALYZER. Features

PM174 PM174 IEEE1159 ADVANCED POWER QUALITY ANALYZER. Features PM174 IEEE1159 ADVANCED POWER QUALITY ANALYZER The PM174 is a compact, multi-function, three-phase AC powermeter and power quality analyzer specially designed to meet the requirements of users ranging

More information

Item E2CD-C1C3A E2CD-C1R5C3A E2CD-X2R5C3A E2CD-X5C3A 12 to 24 VDC (10 to 30 VDC), ripple (p-p): 10% max.

Item E2CD-C1C3A E2CD-C1R5C3A E2CD-X2R5C3A E2CD-X5C3A 12 to 24 VDC (10 to 30 VDC), ripple (p-p): 10% max. Sensing distance 1.0 mm 1.5 mm 2.5 mm 5.0 mm High-precision Proximity Sensor Supply voltage 12 to 24 VDC Output 100 ma max., 2 outputs Ideal for Positioning and Discriminating Objects Assures minimal temperature

More information

SALES NUMBER NUMBER OF BEAMS PROTECTIVE HEIGHT

SALES NUMBER NUMBER OF BEAMS PROTECTIVE HEIGHT SECTION 21 182 Safety Light Curtains Type: SLC-F Finger (14mm) FEATURES: Resolution: 14mm Protective height: 160mm to 1040mm Type 4 according to IEC61496-1 and -2 ORDERING INFORMATION: SALES OF BEAMS PROTECTIVE

More information

LH-50. High-precision measurement using safe LED beam LED TYPE OPTICAL DISPLACEMENT SENSOR. LH01caE0(00/6/28) 01.2.

LH-50. High-precision measurement using safe LED beam LED TYPE OPTICAL DISPLACEMENT SENSOR. LH01caE0(00/6/28) 01.2. LH01caE0(00/6/28) 01.2.14 9:19 PM Page H1 LED TYPE OPTICAL DISPLACEMENT SENSOR High-precision measurement using safe LED beam Conforming to EMC Directive LH01caE0(00/6/28) 01.2.14 9:19 PM Page 1 Minute

More information

Model Number Structure

Model Number Structure Solid State Relays with Failure Detection Function G3PC CSM_G3PC_DS_E_1_1 Refer to Safety Precautions for All Solid State Relays. Detects failures in SSR used for heater temperature control and simultaneously

More information

ICP DAS. ICP DAS 2015 M2M WLAN Wireless Solutions

ICP DAS. ICP DAS 2015 M2M WLAN Wireless Solutions ICP DAS 2015 M2M WLAN Wireless Solutions Industrial Computer Industrial Product Data Computer Acquisition Product System Data Acquisition System PAC WLAN Wireless Solutions Wi-Fi Products WLAN Converter

More information

Light ON 5m. * Light ON. 2.5m (3m) Light ON. (5m)

Light ON 5m. * Light ON. 2.5m (3m) Light ON. (5m) All voltage photoelectric sensors Built-in amplifier accepts wide supply voltage range. Slim, space-saving construction measures only x x 7.4 mm. s with long life expectancy and high switching capacity

More information

Transistor drive 2c/4c 5A slim power relays

Transistor drive 2c/4c 5A slim power relays Transistor drive c/c 5A slim power relays NC RELAYS NC Flat type () NC (Plug-in type) RoHS compliant NC Flat type () NC () FEATURES 1. Compact, slim design Use of high-performance flat electromagnetic

More information