Quick Start Installation Guide

Size: px
Start display at page:

Download "Quick Start Installation Guide"

Transcription

1 RM-DCM-2 Quick Start Installation Guide Version G0 Document Part Number UM-215 May 2010 OVERVIEW The RM-DCM-2 is a UL294 Listed and UL1076 Listed door control module that includes the RM-4E Reader Module (RM-4E) and enclosure. The RM-DCM-2 is designed to support up to two RM-4E modules, providing a single enclosure for doors with IN and OUT readers. The enclosure also has space for up to three I/8 and/or R/8 boards, for a total of four boards. The RM-DCM-2 supports an optional battery (12 VDC, 4A), which will be recharged by the RM-4E battery charging circuit. The RM-4E board provides the hardware interface between Magnetic signaling read heads or Wiegand signaling read heads and the apc/8x, istar, and istar Pro hardware. The RM-4E also provides inputs and outputs that communicate between door components and the apc/8x, istar, and istar Pro hardware. The I/8 module provides eight supervised inputs and the R/8 module provides eight dry contact, Form C relay outputs. The RM-DCM-2 system consists of two subassemblies: Model RM-DCM-CAN enclosure Model RM-4E board For information about the RM-4E, I/8, or R/8 modules, refer to the Quick Start guides listed in Table 13. All interconnecting products or devices must be UL Listed. 1

2 Overview Table 1 lists the RM-DCM-2 board and enclosure offered by Software House. You can install an RM-DCM-2 up to 4000 feet (1219 meters) from the apc/8x, istar or istar Pro hardware. TABLE 1. RM-DCM-2 Product Offering Product Description Enclosure RM-DCM-2 RM-4E module, with connectors, LEDs, onboard relays, and battery charger. Factory mounted in metal junction box with mountings for optional hardware available from Software House. 2

3 RM-DCM-2 Unit RM-DCM-2 UNIT Figure 1 shows the RM-DCM-2 unit with one RM-4E board, an optional battery, and LCD. UL has evaluated this configuration only. LCD Battery RM-4E FIGURE 1. RM-DCM-2 with Battery and LCD FEATURES RM-DCM-2 features include: LED status indicators display RS-485, inputs, outputs, and power status. Maglock component for use with door objects. Bypass component connects to a release switch on a door secured by a magnetic lock. On-board battery charger supplies power to an optional battery for memory retention in the event of a power failure. The on-board battery is for memory retention only. UL has not evaluated the battery for the Standby Power requirements of the UL294 Standard. 3

4 Features Optional Equipment Read Head Interfaces Optional equipment for the RM-DCM-2 includes: Backup battery kit provides the RM-4E with backup power for memory retention in the event of a power failure. The kit includes a cable assembly that connects the battery to the RM-DCM-2 battery component. LCD component displays diagnostic information and status messages for readers attached to the RM-4E. The optional LCD is attached to the J1 (LCD) connector on the RM-4E board. The RM-4E supports Wiegand signaling or Magnetic read heads. Select the interface you want by setting S5 position 1 on the RM-4E board. Set S5-1 to the On (Closed) position for Wiegand read heads Set S5-1 to the Off (Open) position for Magnetic read heads The RM-DCM-2 has been evaluated by Underwriters Laboratories Inc. (UL) for compatibility with HID Model and HID 5355 readers only. RM-DCM-2 with RM-4E, I/8, R/8, and Battery The RM-4E Reader Module (RM-4E) simplifies installation by providing clearly labeled termination points to identify functionality and device information. The RM-4E also features LEDs for output, RS-485, power, and input status to make it easier to install and service the system. The RM-4E board is installed and mounted at the top of the door. Another RM-4E board and any combination of I/8 and R/8 modules, up to a total of four boards, can be mounted on the door and within the enclosure. Figure 2 shows an RM-DCM-2 unit with one RM-4E, R/8, I/8, and battery. There could also be another RM-4E board, I/8, or R/8 mounted in the space provided within the enclosure. 4

5 Features Tamper Input (SW2) Tamper Switch FIGURE 2. RM-DCM-2 with RM-4E, R/8, I/8, and Battery Tamper Switch The RM-DCM-2 provides a tamper switch as part of the enclosure. 1. Verify or connect the normally closed tamper switch in the enclosure to the 2-pin connector labeled TAMPER (SW2) on the RM-4E board. See Figure Verify or set DIP switch SW5-4 (Tamper Override) to Off (Closed) on the RM-4E. See Figure To configure the tamper: C CURE use the Reader Configuration Advanced dialog box. C CURE use the Reader I/O tab. The switch is normally closed so that when the door is closed the tamper is secure. If the door is forced, the switch will open causing an alarm event. The tamper switch must be connected to comply with UL requirements. 5

6 RM-4E Reader Interface RM-4E READER INTERFACE You can interface read heads that supply Wiegand signaling or magnetic (ABA) signaling to the apc/8x, istar, and istar Pro using RM-4E boards. Figure 3 indicates how an RM-4E board interfaces with Wiegand and Magnetic signaling read heads. FIGURE 3. RM-4E Interface UL has not evaluated magnetic (ABA) signaling read heads. 6

7 RM-4E Reader Interface RM-4E Layout Figure 4 shows the photograph of an RM-4E board with LCD. FIGURE 4. Photograph of RM-4E Board 7

8 RM-4E Components RM-4E COMPONENTS Figure 5 shows the location of connection points, switches, and LEDs on the RM-4E board. RM-4E Board Layout FIGURE 5. RM-4E Board Layout This section lists the RM-4E components starting from the upper right corner of Figure 5 and moving in a clockwise direction. Tamper The RM-DCM-2 tamper input twisted pair wires, shown in Figure 2, are connected to the TAMPER (SW2) input pins. 8

9 RM-4E Components Power In : There are two ways to power an RM-4E: Method A - from the Power In connector using an external power supply, which also charges the battery through the BATTERY connector. Method B - from the RS 485 connector using the apc or istar power supply. Do not use both power connection methods at the same time. A UL Listed power-limited access control or burglar alarm power supply, capable of four hours standby, must be used when the unit is powered from a source other than the apc or istar. +12/24 VDC FIGURE 6. RM-4E Power Wiring - Method A Method A - via Power In Connect +12 or +24 VDC to Pin 2 of the Power IN connector. Connect the ground side of the supply to either Pin 1, 3, or 4. Because the three grounds are all tied together, you can connect the negative side of the supply to any of the three pins. Do not use +24 VDC unless all devices on the bus are RM-4Es. RM-4s, I/8s, R/8s and MRMs must be powered with +12 VDC. The battery charger only works if you power through the Power IN connector. 9

10 RM-4E Components Method B - via RS-485 (RM Bus Connector) Connect +12 VDC to Pin 1 of the RS-485 connector on the bottom right side. Connect Ground (Gnd) to Pin 4 of the RS-485 connector. The +12 VDC input on Pin 1 has a protection diode that prevents you from using the RS-485 connector as a source of +12 VDC if you power through the Power IN connector. Battery Connect the plus and minus sides of the 12 VDC battery to the Battery connector. The battery provides power for memory retention in the event of a power failure. When power is restored, the battery is charged by the power supplied through the Power In connector. LED Connector Table 2 lists LED Connector Signals and Functions on the RM-4E board. TABLE 2. LED Connector Signals and Functions Pin Signal Function 6 Gnd Ground 5 Beep Used to drive an external beeper on a reader connected to the unit. 4 Grn Green LED drive 3 Yel Yellow LED drive 2 Red Red LED drive 1 +5 VDC + 5 VDC, if required UL has not evaluated using Pin 5 to drive an external beeper. Typical LED Scenarios One wire Bi-Color - Attach the brown wire from the read head to the Yellow LED drive on the RM-4E. Two wire Red and Green - Attach the brown wire from the read head to Red LED drive. Attach the orange wire from the read head to the Green LED drive. Three wire Red, Green, Yellow - Attach each LED drive to the associated color LED. See LED Control on page 22 for information. 10

11 RM-4E Components When the wiring gauge is too small or the wiring runs are too long, the Yellow LED drive oscillation can cause cross-talk and result in misreads. RS 485 Reader Bus RS 485 is the reader bus connection to the apc or istar. It is two wire, half duplex RS 485. Connect Tx+ / Rx+ to Pin 2 and connect Tx- / Rx- to Pin 3. The pins are numbered right to left on the connector. TABLE 3. RS 485 Reader Bus Connections Pin Signal Function 4 Gnd Ground 3 D- Tx- / Rx- (usually green) 2 D+ Tx+ / Rx+ (usually white) VDC (if required) Connecting Read Heads Connect read heads to the Read Head connector. Connect either a Wiegand signaling device or a magnetic (ABA) signaling device. Wiegand signaling uses Data 1 and Data 0 lines and magnetic signaling uses Clock and Data. Wiegand Signaling For Wiegand signaling, use the following pinout; set SW5-1 to ON. TABLE 4. Wiegand Signaling Pinout Pin Signal Function 1 D1 Data 1 line (white) 2 D0 Data 0 line (green) 3 N/C No connection 4 +5 VDC +5 VDC if required 5 GND Ground VDC +12 VDC if required 11

12 RM-4E Components Magnetic (ABA) Signaling For Magnetic (ABA) signaling, use the following pinout; set SW5-1 to OFF. TABLE 5. Magnetic (ABA) Signaling Pinout Pin Signal Function 1 CRD N/A 2 STRB Strobe signal 3 DAT Data signal 4 +5 VDC +5 VDC if required 5 GND Ground VDC +12 VDC if required (not used by Software House magnetic read heads) UL has not evaluated magnetic (ABA) signaling read heads. Relay 1, Relay 2, MagLock, and Bypass The RM-4E provides lock components that facilitate connecting magnetic and electric strike locks. Relay 1 is a standard Form C, dry contact relay, identical to the relays found on the istar ACM. Relay 2, along with the MagLock and Bypass connectors have internal etch connections for wiring magnetic and electric strike locks Tie Point (TP1/TP2) connector pins are not connected to the circuitry. They are used as connection points to avoid field splices when connecting locks to Relay1. TP1-1 is tied to TP1-2, and TP2-1 is tied to TP2-2. Lock Connectors The Lock Connector pinouts are shown below. 12

13 Lock Wiring Configurations FIGURE 7. Lock Connectors LOCK WIRING CONFIGURATIONS RM-4E lock connectors support the following wiring configurations: Magnetic Lock using Relay 2 Electric Strike using Relay 2 Electric Strike using Relay 1 The following sections describe how to connect each configuration. The electric strike examples are shown as Fail-Secure. Magnetic Locks The normal state of a magnetic lock has current flowing through an electromagnet on the lock that pulls a strike plate with a force of lbs. Safety codes usually require a bypass switch for emergency egress. This is not the Request to Exit (REX) switch. Note the internal etch connections between Relay 2, Maglock, and the Bypass connector. Connecting a Magnetic Lock The following figure shows an example of connecting the power supply, magnetic lock, and bypass switch. 13

14 Lock Wiring Configurations FIGURE 8. Magnetic Lock Wiring with Jumper Options 14

15 Lock Wiring Configurations Magnetic Lock Components This section describes the components and connections for magnetic lock wiring. Power Supply The power for a magnetic lock must be filtered, regulated direct current (DC) voltage. Alternating current (AC) does not work and half wave rectified DC does not work reliably. Most magnetic locks consume about 3 watts, which is about VDC or VDC. 18 AWG wire is generally recommended. If the wire runs exceed 100 feet, use 16AWG wire instead. The power supply to a magnetic lock must be isolated. Do not connect the output of the power supply or the negative side of the lock to earth ground. The connection from the minus side of the power supply must go to Maglock pin 3. Bypass Switch Connect a normally closed (NC) emergency Bypass switch as shown. Remove the J15 Bypass jumper for normal operation. It will be necessary to connect the J15 Bypass jumper (closed) if you install an electric strike on Relay 2. Diode Protection An optional inductive kickback suppression diode is available by connecting the J13 Diode jumper (closed). Some magnetic locks have the suppression circuitry built-in so in some cases the J13 Diode jumper should be removed (open). RM-4E Power Failure When using the configuration shown, the magnetic lock remains locked if the RM-4E loses connection to the apc or istar because the normally closed (NC) connection of Relay 2 is used. The magnetic lock also remains locked if the RM-4E loses power. 15

16 Lock Wiring Configurations You have the option of wiring to the normally open (NO) connector of Relay 2 if you want to have the Magnetic lock unlock under those conditions. If you use the normally open (NO) connector then Relay 2 will have to be normally energized using the C CURE Administration application. If the power supply fails, the magnetic lock will unlock regardless of whether the normally closed (NC) or normally open (NO) is used. Electric Strikes Unlike magnetic locks, electric strike locks typically lock when not powered and unlock when powered. You must decide if you want to wire for fail-secure or fail-safe. Failsecure means that if there is a power failure, the door goes to a secure or locked state. Fail-safe (fail-open) means that the door is open if there is a failure. It is important that local codes be followed to avoid people getting trapped in an emergency situation. Usually fail-secure doors have crash bars to allow emergency egress. Using Relay 2 for an Electric Strike The same internal connections that are used for a magnetic lock can be used to wire an electric strike. Connect the plus side of the power supply to the normally open (NO) connection of Relay 2 and connect the remaining external connections the same as the magnetic lock 16

17 Lock Wiring Configurations FIGURE 9. Relay 2 Fail Secure Wiring 17

18 Lock Wiring Configurations Electric Strike Components This section describes components and connections for electric strike wiring using Relay 2. Bypass Switch Connect the J15 Bypass jumper (closed) to provide the internal connection from Maglock Pin 1 to the C contact of Relay 2. Do not connect an external bypass switch. Diode Protection An optional surge suppression diode is available by connecting the J13 Diode jumper (closed). If the electric strike has a suppression diode builtin, disconnect the J13 Diode jumper (open). Using Relay 1 for an Electric Strike Relay 1 is a standard Form-C dry contact relay. Wiring door strikes using this relay on the RM-4E is the same as wiring them to apcs, istars, R/ 8s etc. Two pair of isolated tie points have been added to minimize splices. Connect the strike and the power supply as shown. There is no internal etch to consider when using Relay 1. In the example below, a fail-secure door is shown with the normally open (NO) contact. You can add an optional external suppression diode, if desired. 18

19 Inputs FIGURE 10. Relay 1 - Fail Secure Wiring INPUTS Input 1 and Input 2 Connect inputs using the standard Software House supervision for either NO or NC. Figure 11 shows an example of wiring Normally Open (NO) and Normally Closed (NC) inputs. FIGURE 11. Input Wiring 19

20 Inputs To comply with UL requirements, use shielded, minimum 22 AWG stranded, twisted pair cable for monitor points, DSMS, and REXs. Use Belden 9462 or equivalent. LED Input Status Each input uses a Red, Yellow, or Green LED to show the input status. Only one color will be on at a time for each input. Table 6 lists the LED color and the corresponding input status. Red LED indicates alert (nominal 500 ohms or 2K ohms). Green LED indicates secure hardware state (nominal 1k ohms). Yellow LED indicates supervision error (open circuit, shorted, or line fault). The RM-4E input status LEDs show flashing status if the RM-4E is communicating with the apc or istar and at least one input or output is configured, or the reader is being used on a door. (The apc or istar needs a configured reason to communicate.) TABLE 6. LED Input Status LED Color Input Status Red Green Yellow Alert (nominal 500 ohms or 2K ohms). Secure hardware state (nominal 1k ohms). Supervision error (open circuit, shorted, or line fault) 20

21 Inputs SW 5 DIP Switch Functions The SW 5 DIP switch on the RM-4E is similar to the SW 3 DIP switch on the RM-4. TABLE 7. SW 5 DIP Switch on RM-4E and SW 3 DIP Switch on RM-4 SW 5 DIP Switch on RM-4E Function Value Equivalent DIP Switch on RM-4 SW 5-1 Reader Type Off = Magnetic (ABA) signaling, On = Wiegand signaling, SW 5-2 LED Control Off = Normal, On = One-Wire (A,B,C) SW 5-3 LED Control Off = Normal, On = External Bi-color SW 5-4 Tamper Off = Normal Tamper, On = Inhibit Tamper SW 5-5 RS-485 Termination Off = Not last in line, On = Last in line SW 3-1 SW 3-6 SW 3-3 SW 3-4 SW 3-5 SW 5-6 Input 1 and Input 2 LED Control Off = Do not display LEDs, On = Display LEDs N/A SW 5-7 Not Used Not Used N/A SW 5-8 Not Used Not Used N/A Note: On = Closed, Off = Open 21

22 LED Control LED CONTROL SW5-3 and SW5-2 control the reader LED display. SW5-3 and SW5-2 provide the same LED control that is available on the RM-4 and the istar ACM. Table 8 shows the possible settings of SW5-3 and SW5-2. TABLE 8. SW5 LED Control SW5-3 SW5-2 Function OFF OFF 3-wire (R,G,Y) ON OFF External Bi-color (Normal External Bi-color) OFF ON 1 Wire (A,B,C) ON ON Special RM-4E 1-Wire LED Control Three Wire LED Control When both SW5-3 and SW5-2 are Off, it specifies Three wire LED control. In this case, the Red, Green, and Yellow LED drives are wired to the associated LED of the same color as shown in Figure 12. FIGURE 12. Three wire LED control 22

23 LED Control RM LEDs Table 9 describes the various conditions indicated by the red, green, and yellow RM reader LEDs. TABLE 9. RM Reader LED Indications Red LED Yellow Green Indication Brief flash Brief flash Brief flash Power up Off Off Off Online (software flag enabled) Off On Off Online On Off Off Offline or reader tamper Solid for 1 sec. Off Off Access denied Fast flash for 2 sec. Off Off Access denied (Software Flag Enabled) Off Off On Access granted or door unlocked (Software Flag Enabled) Off Off Fast flash Access granted Off Off Slow flash Door unlocked Off Slow flash Off Enter second card (escorted access only) Off Fast flash Off Enter PIN Off Fast flash Off Enter floor # (systems configured for elevator control only) Flash w/ each key press Unchanged Flash w/ each key press Keypad input Slow flash Off Off Reader not configured Fast flash Fast flash Fast flash Alarm: door forced/held open On On On Error condition: Remove power to prevent damage to RM 23

24 LED Control External Bi-color LED Control When SW 5-3 is On and SW5-2 is Off, the function is External Bi-color because there are two LEDs (Red and Green) in the reader. The LEDs will appear as Yellow when both Red and Green are on, making the function essentially a Tri-color (Red, Green, Yellow). Two Wire (Red and Green) There are two cases of External Bi-color two wire and one wire. With two wire, the Red and Green LED drives are wired as shown in Figure 13 FIGURE 13. External Bi-color (2 wire) 24

25 LED Control One Wire (Yellow) With one wire, the Yellow drive is wired as shown in Figure 14. The Yellow LED drive gets inverted in the read head resulting in a Red LED when the signal is low and a Green LED when the signal is high. If the Yellow LED drive is oscillating, the Red and Green LEDs will be oscillating and will appear to the human eye that the LED is Yellow. The RM-4E will oscillate the Yellow drive at 1 KHz when a Yellow LED display is required. FIGURE 14. External Bi-color (1 wire) Special RM-4E 1-Wire LED Control Setting both SW5-3 and SW5-2 On results in a special RM-4E legacy mode that is equivalent to the 1-wire Bi-color mode on earlier versions of the RM-4E. In the standard 1-wire Yellow drive connection, the drive will oscillate, resulting in the appearance of a Yellow LED. In the special mode, the drive does not oscillate and there is no Yellow indication. 25

26 LED Control One Wire (A,B,C) LED Control When SW5-2 is On, it specifies One Wire (A,B,C) mode. In this case, a single LED drive (Red or Green or Yellow) is wired with varying results as shown in Figure 15. One wire mode is typically used for older read heads with a single LED that is either On, Off, or flashing. FIGURE 15. One Wire (A,B,C) LED control 26

27 Installation Requirements INSTALLATION REQUIREMENTS The Software House RM-DCM-2 enclosure accommodates an RM-4E board, as well as three additional Software House boards. The enclosure door is hinged, for ease of installation, and includes a tamper switch and key lock. This section describes the dimensions and installation requirements for the RM-DCM-2 enclosure and modules. Installing the Enclosure Make sure the installation location provides sufficient space for the RM- DCM-2 enclosure, and the necessary electrical conduit. Figure 16 gives the dimensions in inches for mounting the RM-DCM-2 enclosure. FIGURE 16. RM-DCM-2 Enclosure Dimensions (in Inches) 27

28 Installation Requirements Module Dimensions Figure 17 shows the dimensions of the RM-4E, R/8, and I/8 modules. Maximum component height is 0.5 inches (12.7 mm). FIGURE 17. RM-4E, R/8, and I/8 Mounting Hole Dimensions Enclosures UL has approved the RM-DCM-2 enclosure for use with R/8, and I/8 boards. Mounting the RM-4E, R/8, and I/8 Boards To mount the RM-4E, R/8, and I/8 boards in an RM-DCM-2 enclosure, use four 1/ screws and star washers to secure the boards to the mounting studs in the enclosure (see Figure 18). There are four possible mount positions for the three boards in the enclosure. 28

29 Installation Requirements The design ensures that you maintain a minimum of 1/4 spacing between adjacent electronic components, and between electronic components and the enclosure. Mounting Studs Mounting Studs Mounting Studs FIGURE 18. Mounting RM-4E, R/8, and I/8 modules in an RM-DCM-2 Power Supply and Wiring Each module (RM-4E, I/8, R/8) has a typical rating of 125mA, plus another 25mA for each active relay. The need for an external power supply is based on the electrical current available from the apc panel or istar controller power supply, the calculated draw of other boards in the system, and the voltage drop due to wiring length. A UL-Listed power-limited access control or burglar alarm power supply, capable of four hours standby, must be used when the unit is powered from a source other than the apc or istar. Wiring methods shall be in accordance with the National Electric Code (ANSI/NFPA 70), local codes, and the authorities having jurisdiction. Environment Operating temperature ranges for the RM-DCM-2 is F (0-49 C); 85% relative 86 F ± 3 (30 C ± 2 ). The RM-DCM-2 is suitable for indoor use, to be installed within the protected premises. Connect the modules (RM-4E, I/8, R/8) to an RM reader bus on an istar or apc. The modules must be within the maximum wire length range of 4000 ft. (1219 m). 29

30 RM-DCM-2 Specifications RM-DCM-2 SPECIFICATIONS This section includes physical specifications and optimal operating specifications for the RM-DCM-2. UL has evaluated the RM-DCM-2 for indoor use with a range of 0 C to 49 C (32 F to 120 F). Software and Firmware Support Current versions of C CURE 9000 and C CURE 800/8000 system software and firmware support the RM-DCM-2 components. Power Requirements and Specifications Table 10 lists the power requirements and operating specifications of the RM-4E board in the RM-DCM-2 enclosure. TABLE 10. RM-4E Power Requirements and Operating Specifications Requirement RM-4E Power requirements Maximum input (with full load) Relay contact power limits Reader LED output control Reader port output voltage Reader port output maximum current Specification +12/24 VDC 280 ma without reader and relays +12/24 VDC 550 ma maximum with reader and relays Up to 30 VAC/DC, 3.3 A maximum 4.0 VDC to 5.25 VDC, 20 ma maximum 5 VDC or 12 VDC 125 ma (at 5V or 12V) Software House recommends local power when using the battery charging circuit and when the RM-4E is used with high-power, longrange readers. See Power In on page 9 for information. 30

31 RM-DCM-2 Specifications TABLE 11. R/8 and I/8 Requirements and Operating Specifications Requirement Specification/Contact Ratings R/8 module power requirements 125mA at +12 VDC plus 25mA for each Active Relay R/8 relay contact rating - 2A at 30 VDC I/8 module power requirements 125mA at +12 VDC 31

32 Parts List Physical Specifications TABLE 12. RM-DCM-2 Physical Dimensions Requirement Enclosure dimensions Weight (without battery) Specification 14 x 12 x 3.5 in x 30.5 x 8.9 cm. 10 lbs. (4.53 kg.) PARTS LIST Table 13 lists part numbers for the RM-DCM-2 product. TABLE 13. RM-DCM-2 Parts List Description Quantity Part No. RM-DCM-2 Enclosure with RM-4E Module 1 RM-DCM-2 RM-DCM-2 Quick Start Guide 1 UM-215 RM-4E Module optional RM-4E I/8 Module optional AS I/8 Quick Start Guide optional UM-204 R/8 Module optional AS R/8 Quick Start Guide optional UM-205 Compliance The RM-DCM-2 has been tested and certified for compliance with the standards listed below: UL Listed UL 294 UL 1076 Other FCC Part 15B class A CE EN EN

33 Testing the RM-DCM-2 Testing the RM-DCM-2 Required Equipment This section describes the procedures that verify the RM-DCM-2 installation and operation. The following equipment is required. Two 1K Ω resistors An LCD display module (2 line x 16 character), Software House part number RM-LCD Three LEDs A multi-meter to measure voltage and resistance Configuration Requirements You must complete the following configuration requirements before you test the RM-DCM-2: 1. Install the RM-4E. 2. Install the LCD display module into the LCD connector on the RM-4E circuit board. 33

34 Testing the RM-DCM-2 Self-Test Mode The RM-4E has a built-in self-test mode. Perform the steps in this section to run the self-test. 1. Remove power to the RM-4E. 2. Set Rotary Switch SW4 to position To test the reader LEDs, connect three LEDs to the Reader LED port as shown in Figure 19. Connect the anode (long lead) of each LED to Pin 1 (+5v). Cover the LED wires with heat shrink to prevent short circuits. If you are using an older LED that does not have a built-in current-limiting resistor, add a 1K-ohm resistor in series. Cover LED wires with heat shrink to prevent shorting +5v Aux End LED Red Yel Grn FIGURE 19. Connecting LEDs for Self-Test Mode 4. Power up the RM-4E. When you power up the RM-4E: Relays 1 and 2 toggle every second. Reader LED lines Red, Green, and Yellow flash on and off. The LCD displays the information shown in Figure

35 Testing the RM-DCM-2 Indicates the state of supervised inputs Input 1 and Input 2: 0 = Open 1 = Secure 2 = Alarm 3 = Short T = Trouble (Line Fault) Indicates the state of the reader port connections (D1 line, D0 line, and DAT line, in that order): 0 = Closed 1 = Open I 1 = 0 I 2 = 0 W = S 5 = T = 1 K 1 = 0 Indicates the current position of switches 1, 2, and 3 on DIP switch S5: 0 = On (Closed) 1 = Off (Open) Indicates the state of the Tamper enable switch: 0 = Closed 1 = Open Indicates the state of the keypad input lines, where the number after K is the keypad input. The last change is displayed. 0 = Closed 1 = Open FIGURE 20. Self-Test LCD Display 5. To test the supervised inputs, attach a 1K Ω resistor to each input (Input 1 and Input 2) as shown in Figure 21. Prior to installing the resistors, the input state should be open (0). After installing the resistors, the input state should be secure (I1=1 and I2=1). Input 1 Input 2 1K-ohm resistors FIGURE 21. Attaching Resistors to the Supervised Inputs 6. To test each reader line, short to ground, one at a time, each of the three reader data lines (D0, D1, and DAT) on the Reader port. After shorting a data line, the display should show a 1 in the appropriate reader line position to indicate that the data line is low (for example, W=010 when you short the D1 line). After removing the short from the data line, the display should revert to 0 for that reader line. 35

36 Testing the RM-DCM-2 7. To test the tamper switch, short tamper connector SW2-2 to ground. The display should change to T=0. Remove the short. The display should revert to T=1. 8. To test SW5 positions 1, 2, and 3, set each of these DIP switches to the Off (open) position. The display should show S5=111. Set each of these DIP switches to the On (closed) position. The display should show S5= To test the keypad, short to ground each of the eight keypad connectors on port J2 one at a time. The display should indicate that a voltage level change was detected. For example, if you short keypad connector 3, the display should show K3=0, where K3 is the keypad connector number and 0 is the new state. Manual Test Procedure To manually test the RM-DCM-2: 1. Measure the supply voltage to the RM-4E. The voltage can be measured between pin 1 (ground) and pin 2 (supply) on the Power-In connector. The voltage must be +12 Volts (+/-5%) or +24 Volts (+/- 10%). 2. Check the RM-4E address setting. The RM-4E must be set to an unused address when connected to the apc or ISTAR. The LCD will display the switch setting upon power-up. Verify that the displayed reader address is correct for your installation. 3. Check the board for communications to the apc or istar. Observe LEDs DS1 and DS2 on the lower right corner of the RM-4E board. The LEDs should blink rapidly to indicate communication to and from the RM-4E. If the LEDs are not blinking, the RM-4E may not be properly configured in C CURE. 4. Check the supervised inputs. With no switches or resistors connected to the Input 1 and Input 2 lines, the C CURE Monitoring Program should report inputs as Open Loop. When you connect the 1K Ω resistor to the input terminals, the C CURE Monitoring Program should report the input as Open loop cleared. 5. Check the outputs. The outputs can be functionally tested by using the momentary activate feature in the C CURE Monitoring Program. When the outputs are momentarily activated, the relays energize for a few seconds. 36

37 CE Notice The corresponding LED (DS3 for output #1 and DS10 for output #2) will light. The multi-meter can be used to check for continuity between the C and NO pins on connectors Relay1 and Relay2. 6. Check the reader interface. The reader interface can only be tested with the reader chosen for the installation. Reading a card will cause the display to show Access Granted or Access Denied, depending upon the clearance of the card. CE NOTICE This product is in compliance with the CE EMC and Electrical Safety Directives of the European Community when used with the Software House apc or istar products. This unit must be enclosed in a box similar to the units noted in the Enclosures on page 28 in order to be in compliance. 37

38 CE Notice C CURE and Software House, are registered trademarks of Tyco International Ltd. and its Respective Cimpanies. Certain Product names mentioned herein may be trade names and/or registered trademarks of other companies. Information about other products furnished by Software House is believed to be accurate. However, no responsibility is assumed by Software House for the use of these products, or for an infringement of rights of the other companies that may result from their use. RM-DCM-2 Quick Start Installation Guide Document Number: UM-215 Revision: G0 Print Date: May 2010 This manual is proprietary information of Software House. Unauthorized reproduction of any portion of this manual is prohibited. The material in this manual is for information purposes only. It is subject to change without notice. Software House assumes no responsibility for incorrect information this manual may contain. Copyright Tyco International Ltd. All rights reserved. 38

Quick Start Installation Guide

Quick Start Installation Guide apc/l Quick Start Installation Guide Version A2 Document Part Number UM-201 May 2010 OVERVIEW The apc/l is an intelligent access control and alarm monitoring control panel which serves as a basic building

More information

Quick Start Installation Guide

Quick Start Installation Guide RM-iCLASS Series Quick Start Installation Guide Version C0 Document Part Number UM-208 June 2009 OVERVIEW The RM-iClass Quick Start Installation Guide provides a summary of installation and connection

More information

istar Pro Installation Guide

istar Pro Installation Guide istar Pro Installation Guide UM-241 Version A1 October 2010 istar Pro Installation Quick Start Guide System Components The istar Pro hardware components consist of: General Controller Module (GCM) A general

More information

Quick Start Installation Guide

Quick Start Installation Guide istar Pro Quick Start Installation Guide Version B0 Part Number UM-069 January 2005 OVERVIEW This guide defines all of the commonly used connection methods to the istar Pro. It outlines how to wire readers

More information

AC-115 Compact Networked Single-Door Controller Hardware Installation and Programming

AC-115 Compact Networked Single-Door Controller Hardware Installation and Programming AC-115 Compact Networked Single- Controller Hardware Installation and Programming Copyright 2013 by Rosslare. All rights reserved. This manual and the information contained herein are proprietary to REL,

More information

KP2000E/EM Series Style Keypad

KP2000E/EM Series Style Keypad 23852973 KP2000E/EM Series Style Keypad Installation and Programming Instructions Models KP2000EXX and KP2000EMXX Specifications Parameter Voltage Requirements Keypad Current Requirements (Max) Relay Contact

More information

SmartLock Pro INSTALLATION MANUAL

SmartLock Pro INSTALLATION MANUAL SmartLock Pro INSTALLATI MANUAL July 2010 Cutting edge simplicity Table of Contents INTRODUCTI... 3 Diodes... 3 Power Supply Notice... 3 Terminal Strips and Cable... 4 SPECIFICATIS... 5 SMARTLOCK CTROLLER

More information

SmartLock Controller INSTALLATION MANUAL

SmartLock Controller INSTALLATION MANUAL SmartLock Controller INSTALLATI MANUAL November 2015 Table of Contents INTRODUCTI... 3 Diodes... 4 Terminal Strips and Cable... 5 SPECIFICATIS... 6 SMARTLOCK CTROLLER LAYOUT... 8 LED Indicators... 9 Mounting...

More information

6222 Two Door Module Technical Operations Manual

6222 Two Door Module Technical Operations Manual 6222 Two Door Module Technical Operations Manual TABLE OF CONTENTS Specifications...3 Overview...4 Operations...5 Custom Access Mode...5 Standard Access Mode...5 Offline Access Mode...5 Offline Memory...5

More information

VertX. V100, V200 and V300. Installation Guide Barranca Parkway Irvine, CA USA. November Rev A.1

VertX. V100, V200 and V300. Installation Guide Barranca Parkway Irvine, CA USA. November Rev A.1 15370 Barranca Parkway Irvine, CA 92618 USA VertX V100, V200 and V300 Installation Guide November 2011 6080-930 Rev A.1. Contents Introduction... 3 Parts List... 3 Product Specifications... 3 Cable Specifications...

More information

Installation Instructions

Installation Instructions Alliance Arming Station AL-1111, AL-1116 1048520C September 2006 Copyright 2006, GE Security Inc. Introduction This is the GE Alliance Arming Station for models AL-1111 (four-line LCD) and AL-1116 (four-line

More information

TruPortal Dual Door Interface Module Quick Reference

TruPortal Dual Door Interface Module Quick Reference TruPortal Dual Door Interface Module Quick Reference en-us Packing List Introduction The TruPortal Dual Door Interface Module (TP-ADD-2D) can support two complete door configurations, with up to two readers

More information

CA-A480-A Elevator Controller. Reference & Installation Manual

CA-A480-A Elevator Controller. Reference & Installation Manual CA-A480-A Elevator Controller Reference & Installation Manual TABLE OF CONTENTS INTRODUCTION.................................................................. 4 Introduction.............................................................................................

More information

Suprex RS-485 SPX-7500 Wired Reader-Extender

Suprex RS-485 SPX-7500 Wired Reader-Extender Suprex RS-485 SPX-7500 Wired Reader-Extender Product Manual SPX-7500_MAN_181206 Cypress Integration Solutions 35 Years of Access Control Ingenuity CypressIntegration.com 2018 Cypress Computer Systems 1778

More information

UC-2000 Installation Manual Unicorn Computers Technology Limited

UC-2000 Installation Manual Unicorn Computers Technology Limited UC2000 Installation Manual Copyright 2003. All rights reserved. Table of Contents Specifications 2 Enclosure for the UC2000 Controller 3 Unicorn Access Control System Configuration 4 UC2000 Controller

More information

MR51e Reader Interface

MR51e Reader Interface J4 J TB6 TB5 TB4 TB3 VIN VO TB2 TB J7 2.75 [69.85] 0.2 [5.08] 2.35 [59.69] J3 MR5e Reader Interface Installation and Specifications. General: www.mercury-security.com 2355 MIRA MAR AVE. LONG BEACH, CA

More information

2000 Series e/em Style Keypad Installation and Programming Manual

2000 Series e/em Style Keypad Installation and Programming Manual 2000 Series e/em Style Keypad Installation and Programming Manual Document Number: 6054022 Revision: 0 Date: 12/21/06 Table of Contents Table of Contents Section 1: Introduction... 6 1 Product Description...6

More information

CRC220 and CRC221 INSTALLATION GUIDE. REF No.: DOC0014 ISSUE: 09

CRC220 and CRC221 INSTALLATION GUIDE. REF No.: DOC0014 ISSUE: 09 CRC220 and CRC221 INSTALLATION GUIDE REF No.: DOC0014 ISSUE: 09 30th July 2015 2 Contents CRC220 & CRC221 INSTALLATION GUIDE 1. Scope 1-1 2. Introduction 2-1 2.1 Features 2-1 2.1.1. PCB Features 2-1 2.1.2.

More information

PXL-250 Tiger Controller

PXL-250 Tiger Controller PXL-0 Tiger Controller This quick start guide is made up of specification sheets, a DO/DON T list, basic installation drawings, first time power-on instructions, and short descriptions of key terms and

More information

Two Door Controller GEN-045

Two Door Controller GEN-045 Australian Owned, Designed and Manufactured Two Door Controller GEN-045 Genesis Electronics Australia Pty Ltd www.genesiselectronics.com.au Distributed by: Genesis reserves the right to change or modify

More information

MR52 READER INTERFACE

MR52 READER INTERFACE IN IN2 IN3 IN4 INPUTS IN5 IN6 IN7 IN8 C www.mercury-security.com 2355 MIRA MAR AVE. LONG BEACH, CA 9085-755, (562)986-905 FAX (562) 986-9205 MR52 READER INTERFACE Installation and Specifications: This

More information

REX F-0-9 Standalone or Access Controller

REX F-0-9 Standalone or Access Controller REX F-0-9 Standalone or Access Controller Power supply The controller need s external power supply to operate. The Spider W40 power supply is sufficient to power two controllers and two 12V electric strikes

More information

Security Management System by Diebold, Inc. LINX System Hardware Installation Guide

Security Management System by Diebold, Inc. LINX System Hardware Installation Guide Security Management System by Diebold, Inc. LINX System Hardware Installation Guide INSTALLATION GUIDE LINX Integrated Security System WSD 2000 Weatherized Status Display Table of Contents Introduction

More information

FlexPass. ASR Long Range Reader. Installation Guide Jeronimo Road Irvine, CA July 16, 2007 Document Number K , Rev B

FlexPass. ASR Long Range Reader. Installation Guide Jeronimo Road Irvine, CA July 16, 2007 Document Number K , Rev B 9292 Jeronimo Road Irvine, CA 92618-1905 FlexPass ASR-620++ Long Range Reader Installation Guide July 16, 2007 Document Number K02021-000, Rev B FlexPass ASR-620++ Long Range Reader K02021-000 Rev. B Contents

More information

IEI emerge MicroNode Install and Setup Guide. Contents

IEI emerge MicroNode Install and Setup Guide. Contents IEI emerge MicroNode Install and Setup Guide Contents Connecting power and the network to the MicroNode... 2 Using Power over Ethernet (PoE)... 3 or... 3 Using a 12 VDC power supply... 3 Connecting and

More information

Access Control System Document Number: , Rev. D. Installation Guide. Essential Essential Plus Elite 36 Elite 64

Access Control System Document Number: , Rev. D. Installation Guide. Essential Essential Plus Elite 36 Elite 64 Essential Essential Plus Elite 36 Elite 64 Access Control System Document Number: 620-100239, Rev. D Installation Guide USA & Canada (800) 421-1587 & (800) 392-0123 (760) 438-7000 - Toll Free FAX (800)

More information

SINGLE READER EXPANSION MODULE

SINGLE READER EXPANSION MODULE SINGLE READER EXPANSION MODULE INSTALLATION GUIDE A D C - A C X 1 TR- SINGLE READER EXPANSION MODULE The ADC-ACX1 Single Reader Expansion Module provides a solution for interfacing to a one Wiegand reader

More information

INSTALLATION INSTRUCTIONS 921P EntryCheck TM

INSTALLATION INSTRUCTIONS 921P EntryCheck TM 80 Avenida Acaso, Camarillo, Ca. 90 (805) 494-06 www.sdcsecurity.com E-mail: service@sdcsecurity.com INSTALLATION INSTRUCTIONS 9P EntryCheck TM The EntryCheck 9P Indoor/Outdoor Keypad is a surface mount

More information

TAC I/NETTM 1284, 1280, Security Control Unit

TAC I/NETTM 1284, 1280, Security Control Unit TAC I/NETTM The SCU () family of modular, stand-alone controllers are basic building blocks of the I/NET Seven Security Management System, and provide a flexible mix of door control and alarm monitoring

More information

MODEL KP-100 ACCESS CONTROL DIGITAL KEYPAD OPERATING INSTRUCTIONS

MODEL KP-100 ACCESS CONTROL DIGITAL KEYPAD OPERATING INSTRUCTIONS MODEL KP-100 ACCESS CONTROL DIGITAL KEYPAD OPERATING INSTRUCTIONS Model KP-100 is a self-contained digital keypad. This keypad is suitable for residential, industrial, and commercial installations. It

More information

Suprex Fiber Optic. Reader-Extender SPX-7400 SPX Product Manual. Reader-Extender. Manual. SPX-7400 Series EXP Suprex_FiberOptic_MAN_170502

Suprex Fiber Optic. Reader-Extender SPX-7400 SPX Product Manual. Reader-Extender. Manual. SPX-7400 Series EXP Suprex_FiberOptic_MAN_170502 Suprex Fiber Optic Reader-Extender SPX-7400 SPX-7410 Product Manual Reader-Extender Manual SPX-7400 Series EXP-2000 Suprex_FiberOptic_MAN_170502 Cypress Integration Solutions 30+ Years of Access Control

More information

Digital Keypad Introduction

Digital Keypad  Introduction K2 Digital Keypad Introduction The K02 uses the latest microprocessor technology to operate door strikes and security systems that require a momentary (timed) or latching dry contact closure. All programming

More information

Access control panel U-Prox IC E (Elevator control)

Access control panel U-Prox IC E (Elevator control) 1.003 Access control panel U-Prox IC E (Elevator control) Installation and programming manual About this document http://u-prox.com This manual covers installation, adjustment and use of U-Prox IC E (hereinafter

More information

TS0867 Four-Door & TS0869 Four-Lift Controller Installation Manual

TS0867 Four-Door & TS0869 Four-Lift Controller Installation Manual TS0867 Four-Door & TS0869 Four-Lift Controller Installation Manual P/N MAINST-867/869 REV 07 ISS 26NOV13 Copyright Trademarks and patents Manufacturer ACMA compliance Contact information 2013 UTC Fire

More information

genesis TECHNICAL MANUAL Two-Door Controller GEN-045

genesis TECHNICAL MANUAL Two-Door Controller GEN-045 Two-Door Controller GEN-045 Genesis Electronics Australia Pty Ltd www.genesiselectronics.com.au info@genesiselectronics.com.au Australian Owned, Designed and Manufactured Distributed By:- Genesis reserves

More information

CA111x-series Arming Station

CA111x-series Arming Station GE Security CA111x-series Arming Station Installation and Programming Guide Contents Page Product Overview...1 Removing the Covers...2 Mounting the RAS...3 Tamper Switch...3 DIP Switch Settings...3 Connections...4

More information

GV-AS Controller. Installation Guide

GV-AS Controller. Installation Guide GV-AS Controller Installation Guide Before attempting to connect or operate this product, please read these instructions carefully and save this manual for future use. 2011 GeoVision, Inc. All rights reserved.

More information

Custom Controller Installation Instructions

Custom Controller Installation Instructions MODEL CUSTOM CONTROLLER HARDWARE CODE MAX ALLOWABLE AMBIENT TEMP: 70 C (158 F) THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES. OPERATION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS: 1) THIS DEVICE MAY

More information

SPX-7400_SPX-7410_MAN_161028

SPX-7400_SPX-7410_MAN_161028 Suprex Fiber Optic SPX-7400 & SPX-7410 Suprex Reader-Extender Data Sheet SPX-7400 Series EXP-2000 SPX-7400_SPX-7410_MAN_161028 1 Cypress Suprex SPX-7400 & SPX-7410 Overview The Suprex Fiber Optic SPX-7400

More information

EA500. Installation Instructions Transponder

EA500. Installation Instructions Transponder EA500 EN Installation Instructions Transponder EA500 Installation Instructions 1.0 Overview EN 2 1.0 Overview The EA500 Transponder is the Security Escort module that provides communications between the

More information

Installation Instructions Installation Guidelines. Product Summary. For the maximum number of bus devices and touchpads per panel see Table 1.

Installation Instructions Installation Guidelines. Product Summary. For the maximum number of bus devices and touchpads per panel see Table 1. Document Number: 466-1632 Rev. B September 2000 Product Summary The ITI SuperBus 2000 2 x 20 LCD (liquid crystal display) Alphanumeric Touchpad gives you complete on-site system programming and operation

More information

The Programmable 4-Way Relay Card is an optional peripheral unit that provides four individually programmable relay output circuits.

The Programmable 4-Way Relay Card is an optional peripheral unit that provides four individually programmable relay output circuits. Peripheral Relay The Programmable 4-Way Relay Card is an optional peripheral unit that provides four individually programmable relay output circuits. Up to 16 Cards can be connected to a multi-loop panel

More information

INSOMNIAC CIA G-600 Gateway Installation Manual P/N CIA Revision 1.0 Date Code:

INSOMNIAC CIA G-600 Gateway Installation Manual P/N CIA Revision 1.0 Date Code: INSOMNIAC CIA G-600 Gateway Installation Manual P/N CIA-675-001 Revision 1.0 Date Code: 1-1-2018 Table of Contents Table of Figures... 3 SPECIFICATIONS:... 4 INSTALLATION... 5 General:... 5 Physical Installation

More information

DG-800 Stand-Alone Proximity Reader Instruction Manual

DG-800 Stand-Alone Proximity Reader Instruction Manual DG-800 Stand-Alone Proximity Reader Instruction Manual I. Features 1. Memory volume up to 1000+10 proximity cards/tokens and PINs with the programming time up to 0.5 seconds. 2. Access modes: a. Only Proximity

More information

INSTALLATION INSTRUCTIONS 920P EntryCheck TM

INSTALLATION INSTRUCTIONS 920P EntryCheck TM 801 Avenida Acaso, Camarillo, Ca. 93012 (805) 494-0622 www.sdcsecurity.com E-mail: service@sdcsecurity.com INSTALLATION INSTRUCTIONS 920P EntryCheck TM The EntryCheck 920P Indoor/Outdoor Keypad is a surface-mount

More information

180 Series Keypad. Handbook. Revision 2.1

180 Series Keypad. Handbook. Revision 2.1 180 Series Keypad Handbook Revision 2.1 Revision History Revision 1.0 Initial release Revision 2.0 Major update with addition of 180-40 Added 180-40 to document and various headings Note regarding unique

More information

Installation Manual Rev D MiniProx Readers - Wiegand 5365B and Clock and Data 5368B

Installation Manual Rev D MiniProx Readers - Wiegand 5365B and Clock and Data 5368B Installation Manual - 5365-902 Rev D MiniProx Readers - Wiegand 5365B and Clock and Data 5368B Web page, E-mail - www.prox.com MiniProx Reader Installation Manual 5365-902 REV D 1 of 7 MiniProx Reader

More information

INSTALLATION INSTRUCTIONS Model 930 EntryCheck

INSTALLATION INSTRUCTIONS Model 930 EntryCheck SECURITY DOOR CONTROLS 3580 Willow Lane, Westlake Village, CA 91361-4921 (805) 494-0622 Fax: (805) 494-8861 www.sdcsecurity.com E-mail: service@sdcsecurity.com INSTALLATION INSTRUCTIONS Model 930 EntryCheck

More information

WRI400 WIRELESS READER INTERFACE

WRI400 WIRELESS READER INTERFACE WRI400 WIRELESS READER INTERFACE Technical Services Training for the WRI400 Launched April 2011 March 12 Technical Services Engineering Support 1 Training Overview WRI400 Description Information Installation

More information

Installation guide for PR302 v2.0 Rev. E

Installation guide for PR302 v2.0 Rev. E Installation guide for PR302 v2.0 Rev. E 2016 ROGER sp. z o.o. sp.k. All rights reserved. This document is subject to the Terms of Use in their current version published at the www.roger.pl website of

More information

PRT-RDS2 Standard 2 Reader Expander

PRT-RDS2 Standard 2 Reader Expander PRT-RDS2 Standard 2 Reader Expander Installation Manual CONTENTS Protégé System... Introduction... Reader Expander... Features... Reader Expander Specifications... Protégé System Management Suite... Protégé

More information

Connecting a Cisco Output Module

Connecting a Cisco Output Module CHAPTER 5 Overview The optional Cisco Output Module (Figure 5-1) is attached to a Cisco Physical Access Gateway or Cisco Reader Module to provide additional connections for up to 8 outputs, each of which

More information

INSTALLATION INSTRUCTIONS 920 EntryCheck TM

INSTALLATION INSTRUCTIONS 920 EntryCheck TM 801 Avenida Acaso, Camarillo, Ca. 93012 (805) 494-0622 www.sdcsecurity.com E-mail: service@sdcsecurity.com INSTALLATION INSTRUCTIONS 920 EntryCheck TM The EntryCheck 920 Indoor/Outdoor Keypad is a surface-mount

More information

Amano (itrt) Intelligent Twin Reader Terminal INSTALLATION MANUAL

Amano (itrt) Intelligent Twin Reader Terminal INSTALLATION MANUAL MODEL NUMBER: XRT910-0-0-AC-XX XRT920-0-0-AC-XX AMANO itrt Amano (itrt) Intelligent Twin Reader Terminal INSTALLATION MANUAL SPECIFICATIONS Working Environment Plastic Housing... Power Designed to work

More information

The Pyramid Series features five readers, each with its own unique characteristics, to meet virtually any requirements an end-user may have.

The Pyramid Series features five readers, each with its own unique characteristics, to meet virtually any requirements an end-user may have. Proximity Readers The Proximity line of OEM Proximity Readers can be used with virtually any manufacturer's access panel because the readers produce industry standard pass-through Wiegand (26-bit or custom

More information

Connecting a Cisco Reader Module

Connecting a Cisco Reader Module CHAPTER 3 Overview The optional Cisco Reader Module (Figure 3-1) is similar to the Cisco Physical Access Gateway, providing the same ports for Weigand readers and other input and output devices. The Cisco

More information

EP1501 Intelligent Controller

EP1501 Intelligent Controller J6 BT K K2 TB5 TB 2.35 [59.69] 2.75 [69.85] EP50 Intelligent Controller with Paired Reader Interface for One Physical Barrier Installation and Specifications: www.mercury-security.com 2355 MIRA MAR AVE.

More information

Installation & Operation Guide

Installation & Operation Guide Installation & Operation Guide (Shown with optional Override Board Cover) KMD-5831 Programmable Loop Controller PLC-28 Direct Digital Controller 902-019-04B 1 Introduction This section provides a brief

More information

WAC-IPMG200 IP Based Access Control System

WAC-IPMG200 IP Based Access Control System WAC-IPMG200 IP Based Access Control System 1. Technical Specifications 2 Door Controller Size (box) 350mm x 360mm x 85mm Temperature -5 C to +50 C Power Main Power : 220-240VAC, 50/50Hz, Power for main

More information

Installation Guide. Avigilon ACM Embedded Controller

Installation Guide. Avigilon ACM Embedded Controller Installation Guide Avigilon ACM Embedded Controller 2016, Avigilon Corporation. Portions 2003-2014 HID Global Corporation. All rights reserved. AVIGILON, the AVIGILON logo, ACCESS CONTROL MANAGER and ACM

More information

NCH-1000 (Multiple Breaker Types) Installation Instructions

NCH-1000 (Multiple Breaker Types) Installation Instructions 20M1 12345678 NCH-1000 (Multiple Breaker Types) Installation Instructions DOC. #560502100 C 7/30/04 PRINTED IN U.S.A. Regulatory Compliance Safety This device has been tested and found to be in compliance

More information

Model HM-535 Power Supply Installation and Service Instructions

Model HM-535 Power Supply Installation and Service Instructions Model HM-535 Power Supply Installation and Service Instructions 430-535 0104 2004 Heritage MedCall, Inc SENTRY INSTALLATION & SERVICE INSTRUCTIONS POWER SUPPLY UNIT Model HM-535 IMPORTANT SAFETY INSTRUCTIONS

More information

ICS Regent. Relay Output Modules. Low Power and High Power (T3446L and T3446H) PD-6017

ICS Regent. Relay Output Modules. Low Power and High Power (T3446L and T3446H) PD-6017 ICS Regent PD-6017 Relay Output Modules Low Power and High Power (T3446L and T3446H) Issue 1, March, 06 Relay output modules provide control of eight user output loads. Two types of relay output modules

More information

CDN503 HIGH DENSITY I/O ADAPTER USER GUIDE

CDN503 HIGH DENSITY I/O ADAPTER USER GUIDE CDN503 HIGH DENSITY I/O ADAPTER USER GUIDE 13050301 (c) Copyright DIP Inc., 1996 DIP Inc. P.O. Box 9550 MORENO VALLEY, CA 92303 714-924-1730 CONTENTS DN503 PRODUCT OVERVIEW 1 DN503 INSTALLATION 1 POWER

More information

Integriti 8-32 Zone LAN Expander Module Kit INSTALLATION MANUAL

Integriti 8-32 Zone LAN Expander Module Kit INSTALLATION MANUAL Revision 2.1 July. 2014 1 Integriti 8 32 Zone LAN Expander Module Kit P/N: 996005PCB&K For Rev. B PCB. INSTALLATION MANUAL Overview The Integriti 8 Zone Expander Module provides an additional 8 Zone inputs,

More information

Installation Instructions 4291 and 4292 Keypads

Installation Instructions 4291 and 4292 Keypads Installation Instructions 4291 and 4292 Keypads A6851J 02/11 Copyright 2011, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the

More information

NS1 Connection Unit Guide

NS1 Connection Unit Guide PURPOSE AND APPLICATION Connection Unit Guide The connection unit is an installation friendly device, which makes it possible to use all features from a central unit. The CU can also be used to connect

More information

4100/4120-Series and 4010ES Relay Modules Installation Instructions

4100/4120-Series and 4010ES Relay Modules Installation Instructions 4100/4120-Series and 4010ES Relay Modules Installation Instructions Introduction This publication describes the installation procedure for the relay cards listed in the following table. Model Number Description

More information

F6-Fingerprint. Access Control/Reader. User Manual. F6 - Simplified Instruction. (Master Code) # (Factory default:1234) Enter the Programming Mode

F6-Fingerprint. Access Control/Reader. User Manual. F6 - Simplified Instruction. (Master Code) # (Factory default:1234) Enter the Programming Mode -Fingerprint Access Control/Reader Function Description Enter the Programming Mode - Simplified Instruction Operation (Factory default:1234) Change the Master Code Add Fingerprint User Add Card User Add

More information

using optional EMX 190 expansion modules), and makes access decisions based on its own distributed

using optional EMX 190 expansion modules), and makes access decisions based on its own distributed Infinity ACX 700 Access Control Unit The Infinity ACX 700 is a programmable, stand-alone access controller that is a basic building block of the Infinity Security Management System. Each ACX 700 controls

More information

istar Ultra Access Controller For up to 32 Readers 1 Features Supports up to 32 Readers Network Ready 1 / 5

istar Ultra Access Controller For up to 32 Readers 1 Features Supports up to 32 Readers Network Ready 1 / 5 1 / 5 Access Controller For up to 32 Readers 1 istar Ultra is a powerful, networkready controller that supports up to 32 readers 1. The strong feature set answers the most demanding access control requirements

More information

GE Contactless Reader Models 240/245/250 Installation Guide

GE Contactless Reader Models 240/245/250 Installation Guide GE Contactless Reader Models 240/245/250 Installation Guide GE Security, Inc. 791 Park of Commerce Boulevard Suite 100 Boca Raton, Florida 33487 (561) 998-6100 Part Number: 460563001C February, 2004 This

More information

ImproX IXP20 Controller INSTALLATION MANUAL

ImproX IXP20 Controller INSTALLATION MANUAL MODEL NUMBER: ISC920-0-0-GB-XX ISC921-5-0-GB-XX IXP20 CONTROLLER SPECIFICATIONS Working Environment Plastic Housing... Power ImproX IXP20 Controller INSTALLATION MANUAL Designed to work in an indoor (dry)

More information

Pyramid Series Proximity Readers

Pyramid Series Proximity Readers The Proximity line of OEM Proximity Readers can be used with virtually any manufacturer's access panel because the readers produce industry standard pass-through Wiegand (26-bit or custom formats) or magnetic

More information

EP/2 Installation Instructions

EP/2 Installation Instructions 1 2 3 4 7 ENTER 0 5 6 8 9 CLEAR + - LOGIC ONE EP/2 EP/2 Installation Instructions DOC. #569011000 A 7/30/04 PRINTED IN U.S.A. Regulatory Compliance Safety This device has been tested and found to be in

More information

KT-300 DOOR CONTROLLER INSTALLATION MANUAL DN KANTECH SYSTEMS INC.

KT-300 DOOR CONTROLLER INSTALLATION MANUAL DN KANTECH SYSTEMS INC. KT-300 DOOR CONTROLLER INSTALLATION MANUAL NOVEMBER 1999 KT-300 - ENGLISH INSTALLATION MANUAL - INTRODUCTION Part of the DSC group, Kantech Systems Inc. embraces the group's corporate philosophy of providing

More information

emerge Essential Access Control System

emerge Essential Access Control System emerge Essential Access ontrol System Document Number: 620-100239, Rev. Installation Guide Linear LL 1950 amino Vida Roble, Suite 150 arlsbad, A 92008-6517 www.linearcorp.com Notices All rights strictly

More information

SECURITY DOOR CONTROLS 801 Avenida Acaso, Camarillo, Ca (805) Fax: (805)

SECURITY DOOR CONTROLS 801 Avenida Acaso, Camarillo, Ca (805) Fax: (805) SECURITY DOOR CONTROLS 801 Avenida Acaso, Camarillo, Ca. 93012 (805) 494-0622 Fax: (805) 494-8861 www.sdcsecurity.com E-mail: service@sdcsecurity.com INSTALLATION INSTRUCTIONS Model 931 EntryCheck The

More information

THE BRIDGE. Make any Wiegand device wireless with the Sure-fi Bridge FEATURES. Technology

THE BRIDGE. Make any Wiegand device wireless with the Sure-fi Bridge FEATURES. Technology THE BRIDGE Make any Wiegand device wireless with the Surefi Bridge *Housing options sold separately. Keep your Wiegand system connected. Fix faulty Wiegand systems quickly and easily with our wireless

More information

OPERATIONS MANUAL. n.form I/O Expander (RACK MOUNT) Document Number: Rev B

OPERATIONS MANUAL. n.form I/O Expander (RACK MOUNT) Document Number: Rev B OPERATIONS MANUAL n.form I/O Expander (RACK MOUNT) Document Number: 200-0009 Rev B table of contents INTRODUCTION FEATURES & CAPABILITIES 1 WIRING General I/O Configuring The System Using The System 4

More information

CM-110SK Standalone Keypad Installation Instructions

CM-110SK Standalone Keypad Installation Instructions CM-0SK Standalone Keypad Installation Instructions. Packing List Qty Name Remarks 2 2 Keypad User manual Screwdriver Wall plugs Self-tapping screws Torx screw 0.8 x 2.4 Φ(20 mm 60 mm) 0.24 x.2 Φ (6 mm

More information

PIB300 and PIB301 User Guide. Installation and operation instructions for Panel Interface Board

PIB300 and PIB301 User Guide. Installation and operation instructions for Panel Interface Board *P516-097* P516-097 PIB300 and PIB301 User Guide Installation and operation instructions for Panel Interface Board Para el idioma español, navegue hacia www.schlage.com/support Pour la portion française,

More information

GEM-ACM1D Access Control Accessory INSTALLATION INSTRUCTIONS

GEM-ACM1D Access Control Accessory INSTALLATION INSTRUCTIONS 333 Bayview Avenue Amityville, New York 11701 For Sales and Repairs, (800) 645-9445 For Technical Service, (800) 645-9440 R GEM-ACM1D Access Control Accessory INSTALLATION INSTRUCTIONS Napco 2004 WI1221A

More information

Expandable Power Systems

Expandable Power Systems Expandable Power Systems Installation Guide Models Include: Maximal11EV 12VDC @ 4A or 24VDC @ 3A. 12VDC @ 4A or 24VDC @ 3A. Maximal33EV 12VDC or 24VDC @ 6A. 12VDC or 24VDC @ 6A. Maximal37EV 24VDC @ 10A.

More information

PRO2200 Professional Modular Access Control Hardware

PRO2200 Professional Modular Access Control Hardware PRO2200 Access Control Hardware As a part of the WIN-PAK software controlled hardware family the PRO2200 professional modular access control hardware is an advanced access control panel capable of providing

More information

UNT1100 Series. Binary Output Jumpers AO2 AO1 AO3 AO4 AOCM AOCM AOCM AOCM AO1. AI Switches Job Information N2 Address. Ref N2+ N2- ADDR 0 = ALL OPEN

UNT1100 Series. Binary Output Jumpers AO2 AO1 AO3 AO4 AOCM AOCM AOCM AOCM AO1. AI Switches Job Information N2 Address. Ref N2+ N2- ADDR 0 = ALL OPEN 1 2 8 4 AI6 R R Installation Bulletin UNT1100 Issue Date 0309 UNT1100 Series Introduction The Unitary (UNT) controller (UNT1100 Series) is a digital controller with applications for air handling units,

More information

(1986; Rev. 1989) Molded Case Circuit Breakers and Molded Case Switches. (1985; Rev. 1988) Enclosures for Electrical Equipment (1000 Volts Maximum)

(1986; Rev. 1989) Molded Case Circuit Breakers and Molded Case Switches. (1985; Rev. 1988) Enclosures for Electrical Equipment (1000 Volts Maximum) Section 16306 50/60-HERTZ (HZ) SOLID STATE FREQUENCY CONVERTER Index PART 1 GENERAL PART 2 PRODUCTS 1.1 References 2.1 Frequency Converters 1.2 Factory Tests 2.2 Conduit and Fittings 1.3 Submittals 2.3

More information

Connecting a Cisco Input Module

Connecting a Cisco Input Module CHAPTER 4 Overview The optional Cisco Input Module (Figure 4-1) is attached to a Cisco Physical Access Gateway or Cisco Reader Module to provide additional connections for up to ten input devices. Each

More information

ROSSLARE AC-115. Hardware Installation and User s Guide DOOR MODE 10/01

ROSSLARE AC-115. Hardware Installation and User s Guide DOOR MODE 10/01 ROSSLARE MODE 1 2 DOOR 3 4 5 6 7 8 9 0 # AC-115 Hardware Installation and User s Guide 10/01 ROSSLARE Hardware Installation and User s Guide for the AC-115 Access Control System MODE 1 2 DOOR 3 4 5 6 7

More information

DORMA. Installation Manual Extension kit I/O module in the B6L 4P

DORMA. Installation Manual Extension kit I/O module in the B6L 4P DORMA Installation Manual Extension kit I/O module in the B6L 4P Contents Contents 1 General information......................... 3 1.1 Preface................................. 3 1.2 Correct use.............................

More information

ACX Series. Access Controller for Ethernet

ACX Series. Access Controller for Ethernet Access Controller for Ethernet The controllers are the industry s most powerful all-in-one access controllers designed for both critical government and private sector security applications. 0 Features

More information

ADC7520 SERIES. 1600W Battery Chargers and Power Supplies

ADC7520 SERIES. 1600W Battery Chargers and Power Supplies ADC7520 SERIES 1600W Battery Chargers and Power Supplies Wide output adjustment range 0 72VDC Analog control by external 0-5VDC voltage Temp.comp charging, sense as on option Power fail relay alarm Master-Slave

More information

DOLXFD1000B. Waterproof Access Control/Reader

DOLXFD1000B. Waterproof Access Control/Reader DOLXFD1000B Waterproof Access Control/Reader INTRODUCTION The DOLXFD1000B is a single- entry multi-function Access Controller with integrated keypad and card reader. It is designed and manufactured to

More information

Installation Guide for PR311SE and PR311SE-BK v1.0 Access Controllers Rev. B

Installation Guide for PR311SE and PR311SE-BK v1.0 Access Controllers Rev. B Installation Guide for PR311SE and PR311SE-BK v1.0 Access Controllers Rev. B Introduction This document contains minimum information that is necessary to properly install the device and to perform its

More information

Measurement Systems Datascan Installation and User Guide

Measurement Systems Datascan Installation and User Guide Measurement Systems Datascan Installation and User Guide Supplied By Contents Contents 1. INTRODUCTION... 1 1.1 GENERAL... 1 1.2 DATASCAN MODULE RANGE... 1 1.2.1 Measurement Processors... 1 1.2.2 Analog

More information

ACTpro Single Door IP Controller. Operating & Installation Instructions

ACTpro Single Door IP Controller. Operating & Installation Instructions ACTpro 1500 Single Door IP Controller Operating & Installation Instructions 18-00079 Issue 1 This manual refers to the ACTpro 1500 a TCP/IP based control unit supporting up to 32 doors. Access Control

More information

GV-Card Reader. User s Manual

GV-Card Reader. User s Manual GV-Card Reader User s Manual Before attempting to connect or operate this product, please read these instructions carefully and save this manual for future use. READER-B 2016 GeoVision, Inc. All rights

More information

PRO3200 Professional Modular Access Control Hardware

PRO3200 Professional Modular Access Control Hardware PRO3200 Access Control Hardware As a part of the WIN-PAK software controlled hardware family the PRO3200 professional modular access control hardware is an advanced access control panel capable of providing

More information

CDN502 HIGH DENSITY I/O ADAPTER USER GUIDE

CDN502 HIGH DENSITY I/O ADAPTER USER GUIDE CDN502 HIGH DENSITY I/O ADAPTER USER GUIDE 13050201 (c) Copyright DIP Inc., 1996 DIP Inc. P.O. Box 9550 MORENO VALLEY, CA 92303 714-924-1730 CONTENTS DN502 PRODUCT OVERVIEW 1 DN502 INSTALLATION 1 POWER

More information

SuperBus Hardwire Input Module (HIM) Document Number: Rev. C September 1998

SuperBus Hardwire Input Module (HIM) Document Number: Rev. C September 1998 SuperBus Hardwire Input Module (HIM) Document Number: 466-1033 Rev. C September 1998 SuperBus Hardwire Input Module for installing a magnetic reed switch* that can provide tamper protection when the switch

More information