1 Product Type: Name: Manufacturer: PSEN PSENcode, PNOZsigma Pilz GmbH & Co. KG, Safe Automation Document Release Number: 02 Release Date: 8 May 2012 Application Note - No _EN_02

2 Document Revision History Release Date Changes Chapter Creation all Correction Exclusion of liability We have taken great care in compiling our application note. It contains information about our company and our products. All statements are made in accordance with the current status of technology and to the best of our know-ledge and belief. However, we cannot accept liability for the accuracy and entirety of the information provided, except in the case of gross negligence. In particular it should be noted that statements do not have the legal quality of assurances or assured properties. We are grateful for any feedback on the contents. May 2012 All rights to this publication are reserved by Pilz GmbH & Co. KG. We reserve the right to amend specifications without prior notice. Copies may be made for the user s internal purposes. The names of products, goods and technologies used in this manual are trademarks of the respective companies. Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, Ostfildern, Germany 2/25

3 Support Technical help round the clock! Technical support is available from Pilz round the clock. This service is provided free of charge beyond standard business hours. Americas Brazil Mexico USA (toll free) PILZUSA ( ) Asia China Japan Korea Australia Australia You can reach our international hotline on: Europe Austria Belgium, Luxembourg England France Germany Ireland Italy Scandinavia Spain Switzerland The Netherlands Turkey or mailto:support@pilz.com Pilz GmbH & Co. KG Safe Automation Felix-Wankel-Straße Ostfildern, Germany Telephone: Telefax: pilz.gmbh@pilz.de Internet: Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, Ostfildern, Germany 3/25

4 Contents 1. Useful documentation Documentation from Pilz GmbH & Co. KG Documentation from other sources of information Hardware configuration Pilz products Hardware configuration Application Task Description Monitoring safety gate Series connection PSEN Maximum number of sensors in series Calculation of off-delay time Safety assessment Functional safety Safety-related characteristics in accordance with EN ISO Safety-related characteristics in accordance with EN Circuit diagram of the application Circuit diagram 1/ Circuit diagram 2/ Special features of series connection using PSEN Parallel connection of the solenoids of PSENsgate Increasing of the input voltage for increase the maximum cable length Table of figures Abbreviations PSEN Pilz Sensor PNOZ Pilz E-STOP Positive-guided (DE: Pilz NOT-AUS-Zwangsgeführt) OSSD Output Signal Switching Device Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, Ostfildern, Germany 4/25

5 1. Useful documentation Reading the documentation listed below is necessary for understanding this application note. The availability of the indicated tools and safe handling are also presupposed with the user Documentation from Pilz GmbH & Co. KG No. Description Item No. 1 Pilz international homepage, download section 2 Operating instructions PSEN cs1.1p FR-xx 3 Operating instructions PNOZ s FR-xx 4 Operating instructions PSEN sg1c FR-xx 5 Data sheet PSEN Y junction EN 6 Data sheet PSEN T junction EN 1.2. Documentation from other sources of information No. Description Item No. 1 2 Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, Ostfildern, Germany 5/25

6 2. Hardware configuration 2.1. Pilz products No. Description Order number Version Number 1 PSEN cs1.1p PNOZ s PSEN Y junction PSEN T junction Hardware configuration Fig. 1: Hardware configuration Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, Ostfildern, Germany 6/25

7 3. Application Task 3.1. Description The following example shows the combination of PSENcode as a series connection. In a production line, there are three machine units combined in series with a conveyor belt. The safety gates of the units will be monitored by a PSENcode (S1, S2, S3) respectively and they are evaluated by a PNOZ s4 (A1). At opening of one of the units, the drive (M1) of the conveyor belt is cut off Fig. 2: Application safety gate series connection The process is divided into the following functions: Monitoring Safety Gate 1 Monitoring Safety Gate 2 Monitoring Safety Gate 3 Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, Ostfildern, Germany 7/25

8 Monitoring safety gate The PNOZ s4 (A1) monitors the function of the series connected safety switches PSEN cs1.1p (S1, S2, S3). If at least one of the safety gates is open, the safety contacts from A1 do open, contactors KM1 and KM2 de-energise and the motor (M1) is cut off. Reset The safety relay PNOZ s4 (A1) can be started if the reset button S4 was closed and then released again (monitored reset) and if following conditions are fulfilled. safety gate 1 is closed and safety gate 2 is closed and safety gate 3 is closed and the actuator of safety gate switch S1 is within the response range of S1 and the actuator of safety gate switch S2 is within the response range of S2 and the actuator of safety gate switch S3 is within the response range of S3 and contactors KM1 and KM2 are de-energised. Feedback loop monitoring function The positive-guided N/C contacts of contactors KM1 and KM2 are monitored by the feedback loop S12-S34 of the safety relay (A1). Settings The terminator on the PNOZ s4 must be connected. The operating mode selector switch (mode) on the safety relay PNOZ s4 must be set to "Monitored reset, falling edge without detection of shorts across contacts (In2+)". Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, Ostfildern, Germany 8/25

9 Series connection PSEN For safety series connection, sensors are needed with the ability for series connection. All safety switches PSENini, PSENcode, PSENslock and PSENsgate with two safety inputs can be used. The sensors can be connected directly to an approved evaluation device. The connected sensors act all on the same cut off path. By the safe inputs, the OSSD outputs and the thereby involved self-monitoring of the series connectable PSEN, the masking of errors resulting from the series connection can be excluded. The detection of an error occurs directly in the sensor. The sensor cuts off it s outputs immediately and disables the enable signal for the next sensors and the evaluation device. In order to simplify the wiring of the sensors, for the series circuit the cable separator PSEN Y junction and to evaluate the diagnostic connector PSEN T junction are available. INFO The sensors PSENcode (S1-S3) are approved in accordance with IP67. When using the cable separator PSEN Y junction and suitable connecting cables, the entire sensor part of the series connection will be classified as IP67. In the following some characteristics about handling the PSEN series connection are explained in more detail. Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, Ostfildern, Germany 9/25

10 Maximum number of sensors in series Limitation of the maximum number of sensors in series is defined by three values: The PFHd-value of the safety functions. The maximum acceptable value for off-delay time. The voltage drop of the supply voltage over the input lead. PFHd The PFHd-value of each element in the safety function is added to a total PFHd-value (PFHd total ). Fig. 3: Calculation PFHd PFHd total = PFHd S3 + PFHd S2 + PFHd S1 + PFHd A1 + PFHd Actuator This value (PFHd total ) must not exceed the permissible range of each required safety level (PL/SIL), because the safety classification otherwise falls on a smaller level. Ascending of the first sensor (S1) each individual safety function can be calculated and the number of sensors until the PFHd limit value of the selected safety level can be determined. The detailed description of the calculations for the functional safety is shown in chapter 3.2. Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, Ostfildern, Germany 10/25

11 Off-delay time The off-delay time of the components is a part of the entire admissible turn off time of a safety function (from the actuation of the sensing function till the termination of the hazardous machine function). The admissible turn off time is defined by the machine manufacturer according to the requirements of the machine (risk assessment etc.). The turn-off time is made up from the off-delay time of the complete sensor evaluation and the rundown-time of the machine. Fig. 4: Off-delay time Maximum admissible off-delay time = admissible turn off time rundown-time of the machine The maximum off-delay time is dividing out in the off-delay times of each individual device and sensors of the serial connection. The maximum number of sensors can be determined as one the off-delay times of the actuator, the evaluation device and the sensors sums until the maximum off-delay time computed before is reached. The detailed description of the calculations for the off-delay time is shown in chapter Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, Ostfildern, Germany 11/25

12 Voltage drop of supply voltage over the input lead For considering the fall of voltage, several factors are important: The power supply device for the sensors must be able to provide the necessary power to supply the connected devices. Length, diameter and material of the used connection conductor. General Technical Data for the calculation of the example Condition: Power supply 24V/4A, Connecting cable 0.25mm 2, Sensor cable 0.25mm 2 From Technical Data PSEN cs2.1p: U B: 24V, Power consumption at U B: 2W, Tolerable voltage tolerance -20%/+20% From Technical Data PSEN Y junction: Current rating 2A at 40 C General calculations Current consumption at PSEN (I Sen ) = 2W / 24V = A ~ 84mA The current rating of PSEN Y junction is noted with 2A. Therefore, the entire available current (I avail ) will limit to this value. Max. voltage drop (U fall_max ) up to the sensor = Tolerable negative voltage tolerance at PSEN = 20% (24V) = 24V * 0.2 = 4.8V INFO To increase the maximum cable length, the input voltage can also permanently be increased till the positive voltage tolerance (An example of increasing the input voltage is shown in chapter 4.2). This will not be used in this example. Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, Ostfildern, Germany 12/25

13 Guidelines for calculating the voltage drop on various cable types: Cable type PSS SB BUSCABLE LC 0.1V Sensorkabel 0.25 mm² 0.15V Sensorkabel 0.34 mm² 0.11V Sensorkabel 0.5 mm² 0.07V Voltage drop per 10 m (Cable up-and-down included) and per 100mA Calculation of voltage drop at conductor Length of the sensor lines L1 and L2 is assumed as 5m each. Length of the sensor line L3 is assumed as 20m. Length of the connection line L4 is assumed as 10m. Length of the connection line L5 is assumed as 50m. Fig. 5: Calculation of voltage drop The current in the conductor L1 - L3 is the same as the current of the sensors S1 S3. It is therefore 84mA each line. L3 Factor for the voltage drop = 0.15V (per 10m and 100mA) Factor of the cable length (L3) = 2 = 20m / 10m Factor from the current = 0.84 = 84mA / 100mA Voltage drop over the conductor resistance (U L3 ) = Factor from the current * Factor of the cable length * Factor voltage drop U L3 = 0.84 * 2 * 0.15V = 0.252V ~ 0.26V L1 L2 Factor for the voltage drop = 0.15V Factor of the cable length (L1/L2) = 0.5 = 5m / 10m Factor from the current = 0.84 = 84mA / 100mA U L1/L2 = 0.84 * 0.5 * 0.15V = 0.063V ~ 0.07V Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, Ostfildern, Germany 13/25

14 L4 The summation of the currents I L3 and I L2 results in current of line L4 = 168mA. Factor for the voltage drop = 0.15V Factor of the cable length (L4) = 1 = 10m / 10m Factor from the current = 1.68 = 168mA / 100mA U L4 = 1.68 * 1 * 0.15V = 0,252V ~ 0.26V L5 The summation of the currents I L4 and I L1 results in current of line L5 = 252mA. Factor for the voltage drop = 0.15V Factor of the cable length (L5) = 5 = 50m / 10m Factor from the current = 2.52 = 252mA / 100mA U L5 = 2.52 * 5 * 0.15V = 1.89V ~ 1.89V I L5 < I avail Entire voltage drop The summation of the voltage for the highest total voltage drop (U fall_total ) applies to the farthest connected sensor (S3). U fall_total = U L3 + U L4 + U L5 = 2.41V U fall_total < U fall_max Result: The voltage drop in the example (2.41V) is smaller than the maximum admissible voltage drop up to the sensor of 4.8V. Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, Ostfildern, Germany 14/25

15 Calculation of off-delay time In series connection of multiple devices, the off-delay time is added by the number of intermediary safety switches. Fig. 6: Off-delay times on series connection The calculation values can be taken from the respective Pilz operating manuals. The calculation values (t O_Actuator ) of the motor contactors (Actuator) can be taken from the technical data of the respective manufacturer. In the following examples maximum values are used for the calculation of off-delay time. Example: Actuation S3 Sensor Off-delay time (max) Activator Selection Inputs Actuator of time PSENcode (S3) 20ms 260ms Actuator 260ms 260ms PSENcode (S2) 20ms 260ms Input 20ms 280ms PSENcode (S1) 20ms 260ms Input 20ms 300ms PNOZ s4 (A1) 20ms - Input 20ms 320ms Entire off-delay time (max) at actuation of sensor S3 = 320ms + t O_Actuator Example: Actuation S2 Sensor Off-delay time (max) Activator Selection Inputs Actuator of time PSENcode (S3) 20ms 260ms PSENcode (S2) 20ms 260ms Actuator 260ms 260ms PSENcode (S1) 20ms 260ms Input 20ms 280ms PNOZ s4 (A1) 20ms - Input 20ms 300ms Entire off-delay time (max) at actuation of sensor S2 = 300ms + t O_Actuator. Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, Ostfildern, Germany 15/25 Time accumulated Time accumulated

16 Safety assessment The circuit of PNOZ s4 (A1) is redundant with built-in self-monitoring. The safety function A1 remains effective in the case of a component failure. The correct opening and closing of the safety function relays of A1 is tested automatically in each on-off cycle. The PNOZ s4 has an electronic fuse. With a monitored reset, short circuits in the reset circuit on A1 are detected. Shorts are detected by the OSSD outputs from each PSENcode (S1, S2, S3). The safety relay PNOZ s4 (A1) and contactors KM1 and KM2 must be installed in a single mounting area (control cabinet) in order to exclude a short across the output. The safety relay A1 should be installed in a control cabinet with a protection type of at least IP54. The terminator on the PNOZ s4 must be connected. The distance between two transponder systems PSENcode (S1, S2, S3) must be at least 40 cm. Caution When connecting several units in series, the off-delay time increases in direct proportion to the number of interconnected safety switches. Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, Ostfildern, Germany 16/25

17 3.2. Functional safety Safety-related characteristics in accordance with EN ISO No. Safety function Achieved 1 Machine shut down when a safety gate (S3) is opened. 2 Machine shut down when a safety gate (S2) is opened. 3 Machine shut down when a safety gate (S1) is opened. Prerequisites: Performance Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, Ostfildern, Germany 17/25 Level Safety-related parts of the control system PL e Sensor (PSEN cs 1.1p S3) Sensor (PSEN cs 1.1p S2) Sensor (PSEN cs 1.1p S1) Logic (PNOZ s4 A1) Actuator (contactors KM1, KM2) PL e Sensor (PSEN cs 1.1p S2) Sensor (PSEN cs 1.1p S1) Logic (PNOZ s4 A1) Actuator (contactors KM1, KM2) PL e Sensor (PSEN cs 1.1p S1) Logic (PNOZ s4 A1) No. Description Identification Actuator (contactors KM1, KM2) 1 Common cause failure (CCF): Requirements are considered to be met 2 Mission time: 20 years 3 Operating interval (electromechanical components): Actuator KM1/2 4 Characteristic data of contactors KM1/KM2: B10d 2,000,000 (must be tested on implementation) 3 operations per hour Please note the further requirements of EN ISO , e.g. requirements for avoiding systematic faults.

18 Safety-related characteristics in accordance with EN No. Safety-related control function (SRCF): Achieved Safety 1 Machine shut down when a safety gate (S3) is opened. 2 Machine shut down when a safety gate (S2) is opened. 3 Machine shut down when a safety gate (S1) is opened. Integrity Level Subsystems SIL 3 Sensor (PSEN cs 1.1p S3) Sensor (PSEN cs 1.1p S2) Sensor (PSEN cs 1.1p S1) Logic (PNOZ s4 A1) Actuator (contactors KM1, KM2) SIL 3 Sensor (PSEN cs 1.1p S2) Sensor (PSEN cs 1.1p S1) Logic (PNOZ s4 A1) Actuator (contactors KM1, KM2) SIL 3 Sensor (PSEN cs 1.1p S1) Logic (PNOZ s4 A1) Prerequisites: No. Description Identification Actuator (contactors KM1, KM2) 1 Common cause failure (CCF): ß = 2 % (must be tested on implementation) 2 Proof test interval: 20 years 3 Operating interval (electromechanical components): Actuator KM1/2 5 Characteristic data of contactors KM1/KM2: B10d 2,000,000 Dangerous failure 3 operations per hour Please note the further requirements of EN 62061, e.g. requirements for systematic safety integrity. Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, Ostfildern, Germany 18/25 rate 65 %

19

20

21 4. Special features of series connection using PSEN In this chapter some characteristics of the series connection of PSEN are considered in detail and generally and independently of the previous example Parallel connection of the solenoids of PSENsgate Please note that in the series connection of the safety switches the maximum solenoid current and the permitted switching capability of the evaluation device. If necessary, the solenoids must be operated individually. Calculation of the maximum solenoid current of two parallel connected PSEN sg1c On a parallel connection, all partial currents are added to a total current (I mag_total ). Fig. 7: Calculation of max. solenoid current I mag_total = I mags1 + I mags2 Extract from technical details of PSEN sg1c Max. magnet current t <150 ms = 1,5A I mag_total = 1.5A + 1.5A = 3.0A The total current of the solenoids from two PSEN sg1c sums up to = 3.0A Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, Ostfildern, Germany 21/25

22 Example 1: Controlled by a dual-pole semiconductor output PSSu E F DI OZ 2 Extract from technical details of PSSu E F DI OZ 2: Typ. output current at 1 signal and rated voltage of semiconductor output 2.0A The permitted switching capability of an dual-pole output from a PSSu E F DI OZ 2 amounts = 2.0A Total current > permitted switching capability Result: The total current in the example exceeds the permitted dual-pole output switching capability. The solenoid must not be controlled together, but there have to be used separate outputs according to the permitted switching capacity. Example 2: Controlled by PNOZ m1p relay outputs Extract from technical details of PNOZ m1p: Relay outputs Utilisation category in accordance with EN Safety contacts: DC13 at 24 V (6 cycles/min) 3.0A, 72W The permitted switching capability of PMOZ m1p relay output in accordance with the utilisation category (Control of DC electromagnetics) amounts =3.0A Total current = permitted switching capability Result: The total current in the example relate to the permitted switching capability of the relay output. The solenoids can be controlled together. Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, Ostfildern, Germany 22/25

23 4.2. Increasing of the input voltage for increase the maximum cable length To increase the maximum cable length, the input voltage can permanently be increased by the voltage tolerance. This will be illustrated in the following example. Example: 9 PSEN cs1.1p to be connected in series This must depend on the expected number of sensors and cable lengths of the supply line, the voltage drop of each line are calculated. Used cable: 0,25mm 2 x 20m. Fig. 8: Comparison of different input voltages Case 1: U B : 24V (blue) The sensors are supplied with U B : 24V. The voltage drop across the line is too large. After only two sensors, the tolerance lower limit of the following sensors is exceeded. Case 2: Increasing the input voltage - U B : 24V (green) To increase the maximum cable length, the input voltage U B can be increased to a value which allows the first sensor (PSEN 1) to operate on the upper tolerance limit. The increased supply voltage is outcome of: Tolerance upper limit sensor + voltage drop over the line L1 (U Fall_L1 ) to sensor 1 Fig. 9: Increasing the input voltage Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, Ostfildern, Germany 23/25

24 5. Table of figures Fig. 1: Hardware configuration... 6 Fig. 2: Application safety gate series connection... 7 Fig. 3: Calculation PFHd Fig. 4: Off-delay time Fig. 5: Calculation of voltage drop Fig. 6: Off-delay times on series connection Fig. 7: Calculation of max. solenoid current Fig. 8: Comparison of different input voltages Fig. 9: Increasing the input voltage Recommended printer settings Adobe Acrobat Reader ( ) PDF-XChange Viewer ( ) Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, Ostfildern, Germany 24/25

25 Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, Ostfildern, Germany 25/25

PAScal V } Software. Readme EN-27

PAScal V } Software. Readme EN-27 V1.9.0 } Software Readme- Preface This document is a translation of the original document. All rights to this documentation are reserved by Pilz GmbH & Co. KG. Copies may be made for internal purposes.

More information

PNOZ s2. Safety relays. Operating Manual EN-07

PNOZ s2. Safety relays. Operating Manual EN-07 Safety relays Operating Manual- Preface This document is the original document. All rights to this documentation are reserved by Pilz GmbH & Co. KG. Copies may be made for internal purposes. Suggestions

More information

PNOZ s1. Safety relays. Operating Manual EN-07

PNOZ s1. Safety relays. Operating Manual EN-07 Safety relays Operating Manual- Preface This document is the original document. All rights to this documentation are reserved by Pilz GmbH & Co. KG. Copies may be made for internal purposes. Suggestions

More information

Safety relays PNOZsigma

Safety relays PNOZsigma Safety relays PNOZsigma Configuration guide, safety relays PNOZsigma Technical catalogue 3.2 November 2008 edition Why does Pilz offer more? Because the integrality of our business activities is what sets

More information

PNOZ s9. Safety relays. Operating Manual EN-08

PNOZ s9. Safety relays. Operating Manual EN-08 Safety relays Operating Manual- Preface This document is the original document. All rights to this documentation are reserved by Pilz GmbH & Co. KG. Copies may be made for internal purposes. Suggestions

More information

PSEN 4.2a/b/p/M12. PSEN sensor technology. Operating Manual EN-02

PSEN 4.2a/b/p/M12. PSEN sensor technology. Operating Manual EN-02 PSEN sensor technology Operating Manual- Preface This document is a translation of the original document. All rights to this documentation are reserved by Pilz GmbH & Co. KG. Copies may be made for internal

More information

PNOZ X2.1. } Safety relays. Operating Manual EN-05

PNOZ X2.1. } Safety relays. Operating Manual EN-05 } Safety relays Operating Manual Preface This document is a translation of the original document. All rights to this documentation are reserved by Pilz GmbH & Co. KG. Copies may be made for internal purposes.

More information

Safety relays PNOZsigma

Safety relays PNOZsigma Safety relays PNOZsigma Application examples for project configuration safety relays PNOZsigma Application Manual July 2009 edition Why does Pilz offer more? Because the integrality of our business activities

More information

PASvisu V Readme EN-04

PASvisu V Readme EN-04 V1.2.0 Readme Preface This document is a translation of the original document. All rights to this documentation are reserved by Pilz GmbH & Co. KG. Copies may be made for internal purposes. Suggestions

More information

PNOZ X1. } Safety relays. Operating Manual EN-08

PNOZ X1. } Safety relays. Operating Manual EN-08 } Safety relays Operating Manual Preface This document is a translation of the original document. All rights to this documentation are reserved by Pilz GmbH & Co. KG. Copies may be made for internal purposes.

More information

PNOZ m EF Multi Link. } Configurable control systems PNOZmulti 2. Operating Manual EN-04

PNOZ m EF Multi Link. } Configurable control systems PNOZmulti 2. Operating Manual EN-04 PNOZ m EF Multi Link } Configurable control systems PNOZmulti 2 Operating Manual Preface This document is a translation of the original document. All rights to this documentation are reserved by Pilz GmbH

More information

PNOZ m EF PDP Link. Configurable Control System PNOZmulti. Operating Manual EN 02

PNOZ m EF PDP Link. Configurable Control System PNOZmulti. Operating Manual EN 02 PNOZ m EF PDP Link Configurable Control System PNOZmulti Operating Manual Preface This document is a translation of the original document. All rights to this documentation are reserved by Pilz GmbH & Co.

More information

PNOZ m EF 8DI4DO. Configurable Control System PNOZmulti. Operating Manual EN 02

PNOZ m EF 8DI4DO. Configurable Control System PNOZmulti. Operating Manual EN 02 PNOZ m EF 8DI4DO Configurable Control System PNOZmulti Operating Manual Preface This document is a translation of the original document. All rights to this documentation are reserved by Pilz GmbH & Co.

More information

Unit description. Function description. If the actuator is within the response range, the magnets switch the reed

Unit description. Function description. If the actuator is within the response range, the magnets switch the reed PSEN.p-0 Unit features The actuator PSEN,-0 belongs to the safety switch reed contacts (N/O) Assured operating distance: 8 mm Assured release distance: 6 mm Round design Works magnetically Switching voltage

More information

E-STOP relay, safety gate monitor

E-STOP relay, safety gate monitor Safety relay for monitoring E-STOP pushbuttons, safety gates and light barriers. Approvals Unit features Positive-guided relay outputs: 2 safety contacts (N/O), instantaneous 1 semiconductor output Connection

More information

System expansion. Configurable Control System PNOZmulti. Operating Manual EN 08

System expansion. Configurable Control System PNOZmulti. Operating Manual EN 08 System expansion Configurable Control System PNOZmulti Operating Manual Preface This document is a translation of the original document. All rights to this documentation are reserved by Pilz GmbH & Co.

More information

PNOZ mc4p. } Configurable safety systems PNOZmulti. Operating Manual EN-05

PNOZ mc4p. } Configurable safety systems PNOZmulti. Operating Manual EN-05 PNOZ mc4p } Configurable safety systems PNOZmulti Operating Manual Preface This document is a translation of the original document. All rights to this documentation are reserved by Pilz GmbH & Co. KG.

More information

Operating Manual PDP67 F 8DI ION. Operating Manual PDP67 F 8DI ION PDP67 F 8DI ION. Decentralised periphery. Operating Manual No.

Operating Manual PDP67 F 8DI ION. Operating Manual PDP67 F 8DI ION PDP67 F 8DI ION. Decentralised periphery. Operating Manual No. Operating Manual PDP67 F 8DI ION Operating Manual PDP67 F 8DI ION PDP67 F 8DI ION Decentralised periphery Operating Manual No. 1001643-EN-06 Preface This document is a translation of the original document.

More information

PNOZ ms1p. Configurable Control System PNOZmulti. Operating Manual EN 11

PNOZ ms1p. Configurable Control System PNOZmulti. Operating Manual EN 11 PNOZ ms1p Configurable Control System PNOZmulti Operating Manual Preface This document is the original document. All rights to this documentation are reserved by Pilz GmbH & Co. KG. Copies may be made

More information

PNOZ m ES EtherCAT. Configurable Control System PNOZmulti. Operating Manual EN 02

PNOZ m ES EtherCAT. Configurable Control System PNOZmulti. Operating Manual EN 02 PNOZ m ES EtherCAT Configurable Control System PNOZmulti Operating Manual Preface This document is a translation of the original document. All rights to this documentation are reserved by Pilz GmbH & Co.

More information

Safe timer relay/contact expansion modules

Safe timer relay/contact expansion modules Contact expander module for increasing the number of available contacts, Pulse-on timer relay for step-by-step control of movement sequences, Delay-on energisation timer for unlocking an interlock with

More information

PNOZ m ES RS232. Configurable Control System PNOZmulti. Operating Manual EN-01

PNOZ m ES RS232. Configurable Control System PNOZmulti. Operating Manual EN-01 PNOZ m ES RS232 Configurable Control System PNOZmulti Operating Manual-1002701-EN-01 This document is the original document. All rights to this documentation are reserved by Pilz GmbH & Co. KG. Copies

More information

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous Two-hand control unit for press controllers and safety circuits Approvals Unit features Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous 1 auxiliary contact (N/C), instantaneous 1

More information

PNOZ m ES Profinet. Configurable Control System PNOZmulti. Operating Manual EN 02

PNOZ m ES Profinet. Configurable Control System PNOZmulti. Operating Manual EN 02 PNOZ m ES Profinet Configurable Control System PNOZmulti Operating Manual Preface This document is the original document. All rights to this documentation are reserved by Pilz GmbH & Co. KG. Copies may

More information

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous Gertebild Bildunterschrift Two-hand control device for safety circuits Approvals Zulassungen Unit features Gertemerkmale Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous 1 auxiliary

More information

Drive Technology \ Drive Automation \ System Integration \ Services. Manual. Control Cabinet Inverter MOVITRAC B Functional Safety

Drive Technology \ Drive Automation \ System Integration \ Services. Manual. Control Cabinet Inverter MOVITRAC B Functional Safety Drive Technology \ Drive Automation \ System Integration \ Services Manual Control Cabinet Inverter MOVITRAC B Functional Safety Edition 05/2009 16811216 / EN SEW-EURODRIVE Driving the world Content Content

More information

Original operating instructions Safety relay with relay outputs G1501S / / 2016

Original operating instructions Safety relay with relay outputs G1501S / / 2016 Original operating instructions Safety relay with relay outputs G50S UK 8023637 / 00 02 / 206 Contents Preliminary note...4. Symbols used...4 2 Safety instructions...5 3 Items supplied...6 4 Functions

More information

Original operating instructions Safety relay with relay outputs with and without delay G1502S / / 2016

Original operating instructions Safety relay with relay outputs with and without delay G1502S / / 2016 Original operating instructions Safety relay with relay outputs with and without delay UK G50S 803638 / 00 0 / 06 Contents Preliminary note...4. Symbols used...4 Safety instructions...5 3 Items supplied...6

More information

SIRIUS Safety Integrated. Modular safety system 3RK3

SIRIUS Safety Integrated. Modular safety system 3RK3 Functional Example CD-FE-I-048-V10-EN SIRIUS Safety Integrated Modular safety system 3RK3 Emergency Stop with monitored Start and Protective Door with automatic start according to category 4 in EN 954-1.

More information

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors Unit features Safety features Gertebild ][Bildunterschrift_NOT_Sch.tuer_Licht Safety relay for monitoring E-STOP pushbuttons, safety gates and light beam devices Approvals Gertemerkmale Positive-guided

More information

SNO 4003 K plus. Areas of application for the unit. Connection circuit diagrams. Intended use. Competent persons. Equipment and functional description

SNO 4003 K plus. Areas of application for the unit. Connection circuit diagrams. Intended use. Competent persons. Equipment and functional description SNO 4003 K plus Safety relay for emergency stop and guard door applications SILCL2 in accordance with EN 62061 PL d, Category 3 in accordance with EN ISO 13849-1 Stop category 0 in accordance with DIN

More information

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors Safety relay for monitoring E-STOP pushbuttons, safety gates and light barriers. Approvals Unit features Positive-guided relay outputs: 7 safety contacts (N/O), instantaneous 2 auxiliary contacts (N/C),

More information

PSEN 1.1p-20. } PSEN sensor technology. Operating Manual EN-10

PSEN 1.1p-20. } PSEN sensor technology. Operating Manual EN-10 } PSEN sensor technology Operating Manual- Preface This document is a translation of the original document. All rights to this documentation are reserved by Pilz GmbH & Co. KG. Copies may be made for internal

More information

E-STOP relay, safety gate monitor

E-STOP relay, safety gate monitor Safety relay for monitoring E-STOP pushbuttons and safety gates. Approvals Unit features Positive-guided relay outputs: 2 safety contacts (N/O), instantaneous 1 semiconductor output Connection options

More information

Control unit SG-EFS 104/2W. EN Operating instructions. Innovative by tradition. Version SG-EFS 104/2W 24 V=/~

Control unit SG-EFS 104/2W. EN Operating instructions. Innovative by tradition. Version SG-EFS 104/2W 24 V=/~ Innovative by tradition. Control unit SG-EFS 104/2W EN Operating instructions Version 0.9 1005196 SG-EFS 104/2W 24 V=/~ Original instructions Mayser GmbH & Co. KG Örlinger Straße 1 3 89073 Ulm GERMANY

More information

Safe monitoring relays

Safe monitoring relays monitor for safe standstill monitoring Approvals Block diagram Unit features Positive-guided relay outputs: 2 safety contacts (N/O), instantaneous 1 auxiliary contact (N/C), instantaneous LED indicator

More information

PSEN cs5.1n. PSEN sensor technology. Operating Manual EN 01

PSEN cs5.1n. PSEN sensor technology. Operating Manual EN 01 PSEN sensor technology Operating Manual Preface This document is the original document. All rights to this documentation are reserved by Pilz GmbH & Co. KG. Copies may be made for internal purposes. Suggestions

More information

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors Safety relay for monitoring E-STOP pushbuttons, safety gates and light barriers. Approvals Block diagram Unit features Positive-guided relay outputs: 6 safety contacts (N/O), instantaneous 4 auxiliary

More information

Control unit SG-EFS 104/4L. EN Operating instructions. Innovative by tradition. Version SG-EFS 104/4L AC/DC 24 V

Control unit SG-EFS 104/4L. EN Operating instructions. Innovative by tradition. Version SG-EFS 104/4L AC/DC 24 V Innovative by tradition. Control unit SG-EFS 104/4L EN Operating instructions Version 2 1004128 SG-EFS 104/4L AC/DC 24 V Original instructions Mayser GmbH & Co. KG Örlinger Straße 1 3 89073 Ulm GERMANY

More information

Positive-guided relay outputs: 4 safety contacts (N/O), instantaneous

Positive-guided relay outputs: 4 safety contacts (N/O), instantaneous Contact expander module for increasing the number of available contacts Approvals Unit features Positive-guided relay outputs: 4 safety contacts (N/O), instantaneous LED indicator for: Switch status channel

More information

PNOZ m ES EtherNet/IP. } Configurable control systems PNOZmulti 2. Operating Manual EN-04

PNOZ m ES EtherNet/IP. } Configurable control systems PNOZmulti 2. Operating Manual EN-04 PNOZ m ES EtherNet/IP } Configurable control systems PNOZmulti 2 Operating Manual- Preface This document is a translation of the original document. All rights to this documentation are reserved by Pilz

More information

PNOZ m ES EtherNet/IP. Configurable Control System PNOZmulti. Operating Manual EN 02

PNOZ m ES EtherNet/IP. Configurable Control System PNOZmulti. Operating Manual EN 02 PNOZ m ES EtherNet/IP Configurable Control System PNOZmulti Operating Manual Preface This document is the original document. All rights to this documentation are reserved by Pilz GmbH & Co. KG. Copies

More information

PNOZ m ES ETH. Configurable Control System PNOZmulti. Operating Manual EN 04

PNOZ m ES ETH. Configurable Control System PNOZmulti. Operating Manual EN 04 PNOZ m ES ETH Configurable Control System PNOZmulti Operating Manual Preface This document is a translation of the original document. All rights to this documentation are reserved by Pilz GmbH & Co. KG.

More information

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors Safety relay for monitoring E-STOP pushbuttons and safety gates. Approvals Unit features Positive-guided relay outputs: 5 safety contacts (N/O), instantaneous 1 auxiliary contact (N/C), instantaneous Connection

More information

PNOZ m B0. Configurable Control System PNOZmulti. Operating Manual EN 04

PNOZ m B0. Configurable Control System PNOZmulti. Operating Manual EN 04 PNOZ m B0 Configurable Control System PNOZmulti Operating Manual Preface This document is the original document. All rights to this documentation are reserved by Pilz GmbH & Co. KG. Copies may be made

More information

Positive-guided relay outputs: 4 safety contacts (N/O), instantaneous

Positive-guided relay outputs: 4 safety contacts (N/O), instantaneous ohne Abbildung Contact expansion module for increasing the number of available contacts Approvals PZE X4.1P with universal power supply Unit features Positive-guided relay outputs: 4 safety contacts (N/O),

More information

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors Unit features Safety features Gertebild ][Bildunterschrift Safety relay for monitoring E-STOP pushbuttons and safety gates. Approvals Kein Gerätebild vorhanden Gertemerkmale Positive-guided relay outputs:

More information

Safe monitoring relays

Safe monitoring relays Unit features Unit description Gertebild ][Bildunterschrift_Stillstandswchter Standstill monitor for safe standstill monitoring Approvals Zulassungen Gertemerkmale Positive-guided relay outputs: 2 safety

More information

PSEN cs5.11 M12/8. PSEN sensor technology. Operating Manual EN 01

PSEN cs5.11 M12/8. PSEN sensor technology. Operating Manual EN 01 PSEN sensor technology Operating Manual Preface This document is the original document. All rights to this documentation are reserved by Pilz GmbH & Co. KG. Copies may be made for internal purposes. Suggestions

More information

PSEN cs5.1 M12/8. PSEN sensor technology. Operating Manual EN 01

PSEN cs5.1 M12/8. PSEN sensor technology. Operating Manual EN 01 PSEN sensor technology Operating Manual Preface This document is the original document. All rights to this documentation are reserved by Pilz GmbH & Co. KG. Copies may be made for internal purposes. Suggestions

More information

PNOZ m B0. } Configurable control systems PNOZmulti 2. Operating Manual EN-05

PNOZ m B0. } Configurable control systems PNOZmulti 2. Operating Manual EN-05 PNOZ m B0 } Configurable control systems PNOZmulti 2 Operating Manual Preface This document is a translation of the original document. All rights to this documentation are reserved by Pilz GmbH & Co. KG.

More information

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment FAST SHIPPING AND DELIVERY TENS OF THOUSANDS OF IN-STOCK ITEMS EQUIPMENT DEMOS HUNDREDS OF MANUFACTURERS SUPPORTED

More information

Polymer Electric. Operating Instructions. Control Unit SG-EFS 1X4 ZK2/1 8k2. Version 3

Polymer Electric. Operating Instructions. Control Unit SG-EFS 1X4 ZK2/1 8k2. Version 3 Operating Instructions Control Unit SG-EFS 1X4 ZK2/1 8k2 Version 3 1003100 SG-EFS 104 ZK2/1 8k2 24 V=/~ 7500354 SG-EFS 134 ZK2/1 8k2 230 V~ Original instructions GmbH & Co. KG Polymer Electric Örlinger

More information

Contact expander modules

Contact expander modules Gertebild ][Bildunterschrift Kontakterweiterungen Contact expansion module for increasing the number of available contacts Approvals Zulassungen Unit features Gertemerkmale Positive-guided relay outputs:

More information

ISO INTERNATIONAL STANDARD. Safety of machinery Safety-related parts of control systems Part 1: General principles for design

ISO INTERNATIONAL STANDARD. Safety of machinery Safety-related parts of control systems Part 1: General principles for design INTERNATIONAL STANDARD ISO 13849-1 Second edition 2006-11-01 Safety of machinery Safety-related parts of control systems Part 1: General principles for design Sécurité des machines Parties des systèmes

More information

_Name_Bookmark2_. _Name_Bookmark2_. PNOZmulti Modbus/TCP. PNOZmulti Modular Safety System. Operating Manual No EN-01

_Name_Bookmark2_. _Name_Bookmark2_. PNOZmulti Modbus/TCP. PNOZmulti Modular Safety System. Operating Manual No EN-01 _Name_Bookmark2 Name_Bookmark2_ PNOZmulti Modbus/TCP PNOZmulti Modular Safety System Operating Manual No. 1002104-EN-01 _Name_Bookmark2_ This document is a translation of the original document. All rights

More information

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous Gertebild ][Bildunterschrift Kontakterweiterungen Contact for increasing the number of available contacts Approvals Unit features Gertemerkmale Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous

More information

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors Safety relay for monitoring E-STOP pushbuttons and safety gates. Approvals Unit features Positive-guided relay outputs: 2 safety contacts (N/O), instantaneous 2 safety contacts (N/O), delay-on de-energisation

More information

PSEN cs3.1n. } PSEN sensor technology. Operating Manual EN-03

PSEN cs3.1n. } PSEN sensor technology. Operating Manual EN-03 } PSEN sensor technology Operating Manual Preface This document is a translation of the original document. All rights to this documentation are reserved by Pilz GmbH & Co. KG. Copies may be made for internal

More information

Technical Catalogue PSENmag and PSENcode

Technical Catalogue PSENmag and PSENcode Technical Catalogue PSENmag and PSENcode Non-contact, magnetic and coded safety switches Edition 005-0 Safe utomation from Pilz Exclusion of liability Family business that s close to its customers Pilz

More information

PSEN cs3.1p/m12. } PSEN sensor technology. Operating Manual EN-04

PSEN cs3.1p/m12. } PSEN sensor technology. Operating Manual EN-04 } PSEN sensor technology Operating Manual Preface This document is a translation of the original document. All rights to this documentation are reserved by Pilz GmbH & Co. KG. Copies may be made for internal

More information

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors Safety relay for monitoring E-STOP pushbuttons and safety gates. Approvals Unit features Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous 2 safety contacts (N/O), delay-on de-energisation

More information

E-STOP relay, safety gate monitor

E-STOP relay, safety gate monitor Unit features Safety features Gertebild ][Bildunterschrift Safety relay for monitoring E-STOP pushbuttons and safety gates. Approvals Gertemerkmale Positive-guided relay outputs: 7 safety contacts (N/O),

More information

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors Unit features Safety features Gertebild ][Bildunterschrift_NOT_Sch.tuer_Licht Safety relay for monitoring E-STOP pushbuttons, safety gates and light beam devices Gertemerkmale Positive-guided relay outputs:

More information

Options for ABB drives. User s manual Emergency stop, stop category 0 (option +Q951) for ACS880-07/17/37 drives

Options for ABB drives. User s manual Emergency stop, stop category 0 (option +Q951) for ACS880-07/17/37 drives Options for ABB drives User s manual Emergency stop, stop category 0 (option +Q951) for ACS880-07/17/37 drives List of related manuals Drive hardware manuals and guides ACS880-07 drives (560 to 2800 kw)

More information

Original operating instructions Fail-safe inductive sensor GF711S / / 2013

Original operating instructions Fail-safe inductive sensor GF711S / / 2013 Original operating instructions Fail-safe inductive sensor GF7S 8528 / 5 / 23 Contents Preliminary note...3. Explanation of symbols...3 2 Safety instructions...4 2. Safety-related requirements regarding

More information

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors Gertebild ][Bildunterschrift Safety relay for monitoring E-STOP pushbuttons and safety gates. Approvals Unit features Gertemerkmale Relay outputs: 2 safety contacts (N/O), instantaneous 1 semiconductor

More information

Two-hand control unit

Two-hand control unit Unit features Safety features Gertebild ][Bildunterschrift_Zweihand Two-hand control unit for press controllers and safety circuits Approvals Gertemerkmale Positive-guided relay outputs: 3 safety contacts

More information

Safety-related controls SIRIUS Safety Integrated

Safety-related controls SIRIUS Safety Integrated Functional Example CD-FE-I-018-V30-EN Safety-related controls SIRIUS Safety Integrated with monitored start up to SIL 1 acc. to IEC 62061 and PL c acc. to ISO 13849-1 with a SIRIUS safety relay 3TK28 with

More information

Drive Technology \ Drive Automation \ System Integration \ Services. Manual. MOVITRAC MC07B Functional Safety

Drive Technology \ Drive Automation \ System Integration \ Services. Manual. MOVITRAC MC07B Functional Safety Drive Technology \ Drive Automation \ System Integration \ Services Manual MOVITRAC Functional Safety Edition 12/2011 19396414 / EN SEW-EURODRIVE Driving the world Contents Contents 1 General Information...

More information

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors Unit features Safety features Gertebild ][Bildunterschrift_nur_Not-Halt Safety relay for monitoring E-STOP pushbuttons Approvals Gertemerkmale Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous

More information

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors Unit features Safety gates Gertebild ][Bildunterschrift_NOT_Sch.tuer_Licht Safety relay for monitoring E-STOP pushbuttons, safety gates and light beam devices Approvals Gertemerkmale Positive-guided relay

More information

Drive Technology \ Drive Automation \ System Integration \ Services. Manual. Electronic Motor DRC Functional Safety

Drive Technology \ Drive Automation \ System Integration \ Services. Manual. Electronic Motor DRC Functional Safety Drive Technology \ Drive Automation \ System Integration \ Services Manual Electronic Motor DRC Functional Safety Edition 02/2012 19376812 / EN SEW-EURODRIVE Driving the world Contents Contents 1 General

More information

Programmable Safety Systems PSS-Range

Programmable Safety Systems PSS-Range Programmable Safety Systems PSS-Range PSS Standard Function Blocks MBS Sensor Signal Evaluation Version 1.0 Item No. 21 149-01 The spirit of safety. All rights to this manual are reserved by Pilz GmbH

More information

Technical Catalogue PNOZmulti Product Range

Technical Catalogue PNOZmulti Product Range Technical Catalogue PNOZmulti Product Range System configuration manual PNOZmulti modular safety system March 004 edition Safe Automation from Pilz Pilz, the company Pilz offers more than automation technology

More information

Online data sheet. TR4-SDM03P TR4 Direct NON-CONTACT SAFETY SWITCHES

Online data sheet. TR4-SDM03P TR4 Direct NON-CONTACT SAFETY SWITCHES Online data sheet TR4-SDM03P TR4 Direct A B C D E F H I J K L M N O P Q R S T Detailed technical data Features System part Sensor principle Ordering information Other models and accessories Number of safe

More information

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors Unit features Safety features Gertebild ][Bildunterschrift_nur_Not-Halt Safety relay for monitoring E-STOP pushbuttons Approvals Gertemerkmale Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous

More information

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous Safety relay for monitoring E-STOP pushbuttons. Approvals Unit features Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous 1 auxiliary contact (N/C), instantaneous Safe separation of

More information

Two-hand control unit

Two-hand control unit Unit features Safety features Gertebild Bildunterschrift_gertespezifisch Two-hand control device for safety circuits Approvals Gertemerkmale Positive-guided relay outputs: 2 safety contacts (N/O), instantaneous

More information

PNOZ ml1p. PNOZmulti Modular Safety System. Operating Manual No EN-05

PNOZ ml1p. PNOZmulti Modular Safety System. Operating Manual No EN-05 PNOZ ml1p PNOZmulti Modular Safety System Operating Manual No. 21575-EN-05 This document is a translation of the original document. All rights to this documentation are reserved by Pilz GmbH & Co. KG.

More information

Drive Technology \ Drive Automation \ System Integration \ Services. Manual. MOVITRAC MC07B Functional Safety

Drive Technology \ Drive Automation \ System Integration \ Services. Manual. MOVITRAC MC07B Functional Safety Drive Technology \ Drive Automation \ System Integration \ Services Manual MOVITRAC MC07B Functional Safety Edition 12/2011 19396414 / EN SEW-EURODRIVE Driving the world Contents Contents 1 General Information...

More information

Application Technique. Safety Function: Safety Camera with E-stop

Application Technique. Safety Function: Safety Camera with E-stop Application Technique Safety Function: Safety Camera with E-stop Products: Guardmaster Dual-input Safety Relay, Guardmaster SC300 Safety Camera Safety Rating: PLd, Cat. 3 to EN ISO 13849-1: 2008 2 Safety

More information

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors Unit features Safety features Gertebild ][Bildunterschrift Safety relay for monitoring E-STOP pushbuttons and safety gates. Approvals Gertemerkmale Positive-guided relay outputs: 3 safety contacts (N/O),

More information

PSR-MS60. Safety relay for emergency stop, safety door and light grid monitoring. Data sheet. 1 Description

PSR-MS60. Safety relay for emergency stop, safety door and light grid monitoring. Data sheet. 1 Description SILCL IEC 62061 Safety relay for emergency stop, safety door and light grid monitoring Data sheet 106171_en_01 PHOENIX CONTACT 2015-05-19 1 Description Intended Use The PSR-MS60 safety relay can be used

More information

Datasheet - SRB 301LC/B-24V

Datasheet - SRB 301LC/B-24V 27.01.2016-00:27:16h Datasheet - SRB 301LC/B-24V Guard door monitors and Safety control modules for Emergency Stop applications / General Purpose safety controllers (Series PROTECT SRB) / SRB 301LC/B Fit

More information

SITOP power supply. Selectivity modules. Overview. Safety notes. Description, device design, dimension drawing. Mounting/removal 3

SITOP power supply. Selectivity modules. Overview. Safety notes. Description, device design, dimension drawing. Mounting/removal 3 Overview Safety notes 1 SITOP power supply Manual Description, device design, dimension drawing 2 Mounting/removal 3 Mounting position, mounting clearances 4 Installation 5 Technical data 6 Safety, approvals,

More information

Connection of CET3-AR to Pilz PDP67

Connection of CET3-AR to Pilz PDP67 Connection of CET3-AR to Pilz PDP67 Content Guard locking spring applied power on released according to EN ISO 14119 (closed-circuit current principle)... 2 Components/modules used... 2 EUCHNER... 2 Other...

More information

FSO Webnair FSO Safety Functions Module. ABB Group February 11, 2015 Slide 1

FSO Webnair FSO Safety Functions Module. ABB Group February 11, 2015 Slide 1 FSO Webnair FSO Safety Functions Module February 11, 2015 Slide 1 Competence Requirements for ABB Commissioner / Service Engineer of ACS880 Drives with FSO The integrated Safety Function Module (FSO; option

More information

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors Unit features Positive-guided relay outputs: 2 safety contacts (/O), instantaneous Connection options for: E-STOP pushbutton Reset button LED indicator for: Switch status channel 1/2 Supply voltage See

More information

GuardLogix: Safety Gate Application with SensaGuard Switch

GuardLogix: Safety Gate Application with SensaGuard Switch Safety Application Example GuardLogix: Safety Gate Application with SensaGuard Switch Safety Rating: PLe, Cat. 4 to EN ISO 13849.1 2008 Introduction...2 Important User Information...2 General Safety Information...3

More information

Selection guide Accessories: Cable

Selection guide Accessories: Cable Selection guide Sensor technology accessories Selection guide Accessories: Cable Cable with socket for PSENmag Features Quantity Cable, M8, 4-pin Kabel/cable Cable, M8, 8-pin Straight, screw-on Angled,

More information

Technical Catalogue PSEN non-contact, magnetic safety gate switches

Technical Catalogue PSEN non-contact, magnetic safety gate switches Technical Catalogue PSEN non-contact, magnetic safety gate switches Safe sensors for position and safety gate monitoring November 003 edition Safe utomation from Pilz Pilz, the company Pilz offers more

More information

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors Unit features Safety features Gertebild ][Bildunterschrift_NOT_Sch.tuer_Licht Safety relay for monitoring E-STOP pushbuttons, safety gates and light beam devices Gertemerkmale Positive-guided relay outputs:

More information

Agilent 66000A 1200 W DC Modular Power System, GPIB

Agilent 66000A 1200 W DC Modular Power System, GPIB Agilent 66000A 1200 W DC Modular Power System, GPIB Data Sheet Speed and accuracy for test optimization 8-slot mainframe accepts up to 8 DC power modules 1200 W total DC power output, up to 150 W per module

More information

Technical Catalogue PNOZmulti Product Range

Technical Catalogue PNOZmulti Product Range Technical Catalogue PNOZmulti Product Range System configuration manual PNOZmulti modular safety system March 004 edition Commissioning PNOZmulti modular safety system Requirements Please note the following

More information

Options for ABB drives. User s manual Prevention of unexpected start-up (option +Q957) for ACS880-07/17/37 drives

Options for ABB drives. User s manual Prevention of unexpected start-up (option +Q957) for ACS880-07/17/37 drives Options for ABB drives User s manual Prevention of unexpected start-up (option +Q957) for ACS880-07/17/37 drives List of related manuals Drive hardware manuals and guides ACS880-07 drives (560 to 2800

More information

PSR-SCP- 24DC/SDC4/2X1/B PSR-SPP- 24DC/SDC4/2X1/B

PSR-SCP- 24DC/SDC4/2X1/B PSR-SPP- 24DC/SDC4/2X1/B PSR-SCP- 24DC/SDC4/2X1/B PSR-SPP- 24DC/SDC4/2X1/B Safety Relay for Emergency Stop and Safety Door Circuits INTERFACE Data Sheet 102858_02_en PHOENIX CONTACT - 12/2006 Description The PSR-...- 24DC/SDC4/2X1/B

More information

Connection of CET3-AR to Pilz PDP67

Connection of CET3-AR to Pilz PDP67 Connection of CET3-AR to Pilz PDP67 Content Guard locking spring applied power on released according to EN ISO 14119 (closed-circuit current principle)... 2 Components/modules used... 2 EUCHNER... 2 Other...

More information

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors Unit features Safety features Gertebild ][Bildunterschrift Safety relay for monitoring E-STOP pushbuttons and safety gates. Approvals Gertemerkmale Positive-guided relay outputs: 2 safety contacts (N/O),

More information

Safety relays PNOZsigma

Safety relays PNOZsigma 000001 1.0 000001 1.0 PNOZ s30 Power In 1 In 2 Out 1 Out 2 Fault 750330 000001 1.0 000001 1.0 000001 1.0 Product range Safety relays PNOZsigma Safety relays PNOZsigma The compact safety relays PNOZsigma

More information