1 Installation Notes TII Model 341 Protector (ATT-IS PEC 32918) for MERLIN Communications System In Range Out of Building (IROB) Station Installation By Trained Technician Only WARNING: Failure to follow these instructions could lead to personal injury and property damage. It will also void product warranties on all protected equipment.
2 1. General 1.01 This installation note covers the description and installation of the TII Model 341 Protector. The Model 341 is a protector designed to protect both the control unit and the station terminal of the MERLIN communications system from foreign voltages caused by lightning, power contact, or power induction. Two (2) Model 341 IROB protector units are installed whenever the station terminal is outside of the building but less than 1,000 feet from the MERLIN system control unit (Figure 1). Each Model 341 is orderable via Price Element Code (PEC) The installation must follow requirements as outlined in Article of the National Electric Code Handbook, and AT&T Standard Practice # Other AT&T Practices that describe wiring for a non-fused protector are identified in Section 6. (Section 6 also identifies how to order all of these documents.) 1.02 The Model 341 Protector contains no field-serviceable components. If the protector must be replaced, the presence of hazardous voltages must be investigated before touching any exposed metallic parts. WARNING: Hazardous voltages may be present. Figure 1 Basic IROB Configuration
3 2. Description 2.01 The Model 341 contains both primary and secondary protection (Figure 2) mounted in a plastic housing with a hinged cover. Figure 2 IROB Internal Connections 2.02 The housing includes three (3) grommets for wire penetration, a No. 10 ground stud, and an eight-position modular jack A tie wrap must be inserted through a tab on the hinged cover for security The primary protection consists of four (4) TII 356L encapsulated, maximum-duty, three-electrode gas tube protector modules The solid state secondary surge protection is assembled on a printed wiring board within the Model 341.
4 3. Installation 3.01 Two (2) Model 341 Protectors are required for each IROB station terminal. One is placed where the cable from the control unit leaves the building. The second protector is placed where the cable enters the building in which the IROB station terminal is to be located. These units are intended for mounting in indoor locations only An approved ground is required for proper operation of the IROB protector. An approved ground is an acceptable power service ground, grounded building steel, concrete encased ground, or ring ground. The Model 341 Protector must be attached to an approved ground using No. 10 AWG copper wire or equivalent. The approved ground used for the Model 341 Protector must be bonded to the ground point for the ac power service using No. 6 AWG or equivalent. The wiring and grounding must follow requirements for a non-fused protector as outlined in Article of the National Electrical Code Handbook, and AT&T Standard Practice # Other AT&T Practices that describe wiring for a non-fused protector are identified in Section 6. (Section 6 also identifies how to order all of these documents.) 3.03 Prior to operation of the MERLIN system, the integrity of the local telephone company-provided CO line protectors and grounding must be checked. Verify that the local telephone company has done the following: 1. Equipped the CO lines with protectors 2. Grounded the CO protector ground lugs to an approved ground 3. Bonded the CO protector ground to the ground point used for the ac power service Do not directly attach the Model 341 Protector to the ground lug of the protector block for the CO lines The exposed wire facility serving the station and control unit should enter the building within 10 feet of an approved ground such as the ac power ground. The National Electrical Code requires that the protector be located in, or immediately adjacent to, the structure or building served, and as close as practicable to the point at which the exposed conductors enter or attach Carefully unpack the protector, and select two or three of the five mounting holes Place the unit, with cover down, on some protected surface and remove the flashing from selected holes with the blade of a screwdriver With the door open, position the unit against the mounting surface, and mark the surface where the mounting holes are to be drilled.
5 3.08 Lay the unit carefully aside, and drill lead holes in the mounting surface as marked. If the surface is masonry, use the appropriate hardware Using No. 10 3/4" pan head screws, fasten the Model 341 Protector to the mounting surface. 4. Wiring 4.01 Before making any connections to the wire facilities, ground the protector by connecting a No. 10 AWG insulated solid copper wire to the ground post of the Model 341 Protector. This can be done by stripping off approximately one inch of insulation and wrapping the bare wire around the ground post under the washers and nut Using appropriate fasteners, run the ground wire as straight as possible to the nearest approved ground. See 3.02 for a description of the approved ground If a straight run is not possible, each bend must have a radius of at least nine inches Secure the end of the ground wire to the approved ground using a recommended ground clamp and tag The Voice 1, Voice 2, Control, and Power pairs may now be safely attached to the IROB terminals. (See Figure 2.) 4.06 Terminate the incoming pairs (22-26 AWG copper) on the type 66 quick-connect block located on the left side of the protector. The clips are arranged in descending order starting with the tip of the Voice 1 pair, followed by the ring of the Voice 1 pair, as shown in Figure 2. NOTE: If the incoming pairs are No. 20 AWG, 40 percent copper-clad fuse wire, terminate them directly on the black primary protector modules. Tip is left, and ring is right If out-of-building station cables are exposed to the possibility of power cross, there must be a fuse near the point of entrance. The fuse can be a 2-foot (minimum) length of 26 gauge wire, under a metal enclosure or part of a shielded cable. If the interbuilding wiring is a cable and the cable has a metallic shield, the shield must be bonded to the protector ground at both ends When the wiring of the Model 341 Protector is completed, the IROB station terminal modular cord or control unit modular cord may be plugged into the eight-position modular jack. Feed the modular plug and cord through the rectangular grommet at the bottom right-hand side of the unit, and insert the plug into the jack of the printed circuit board.
6 4.09 When all work is completed in the protector, close the cover by applying light pressure on the external tab until you hear the locking tabs snap shut. A security wire or tie wrap must be inserted into the oval hole. 5. Selection of an Approved Ground 5.01 The first choice for approved ground is some part of the power grounding system (Figure 3). The National Electrical Code requires that the telephone and power grounds be bonded with No. 6 AWG copper wire or equivalents and that an accessible means be provided at the electrical service for bonding other systems, such as telephone systems, to the power. The bonding point means may consist of an accessible metallic service entrance conduit, a power grounding conductor (see the note below), or a connector located on the exterior of the power service raceway or power service equipment (circuit breaker panel). NOTE: In some cases this may be a ground conductor from the interior of the circuit breaker panel which has been left accessible. The approved ground should be installed according to NEC and AT&T Practice # Figure 3 Acceptable Grounding Connections to the Power Ground
7 5.02 Do not connect grounds to the following: Gas pipe Electric service branch circuit conduit Armor of BX cable Interior of any electrical box 6. References National Electrical Code Handbook, 1984, published by the National Fire Protection Association. AT&T Standard Practices. These are available from: Support Services AT&T Information Systems 99 Jefferson Road Room 2E09 Parsippany, New Jersey Telephone Number: Fax Number: AT&T Standard Practices include the following: , Station Protection and Grounds , Electrical Protection Stations and Customer Equipment , Key Telephone system. Ground and Special Protection Requirements xx (entire section of Practices), Wiring at Terminals 462-xxx-xxx (entire division), Drop and Block Wiring
MICHIGAN DEPARTMENT OF TRANSPORTATION
MICHIGAN DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION FOR GROUNDING, BONDING, LIGHTNING PROTECTION AND SURGE PROTECTION FOR INTELLIGENT TRANSPORTATION SYSTEM EQUIPMENT ITS:CLC 1 of 5 APPR:LWB:DBP:07-31-13
More informationReplacing the Power Supply
APPENDIX B This appendix includes information on how to replace the power supply for the Cisco AS550XM universal gateway and contains the following sections: Safety Recommendations, page B-1 Required Tools
More information1993 SPECIFICATIONS CSJ , ETC. & SPECIAL SPECIFICATION ITEM 6132 ARTERIAL TRAFFIC MANAGEMENT SYSTEM
1993 SPECIFICATIONS CSJ 1685-05-068, ETC. & 1685-02-042 1.0 DESCRIPTION SPECIAL SPECIFICATION ITEM 6132 ARTERIAL TRAFFIC MANAGEMENT SYSTEM THIS ITEM DESCRIBES THE OPERATION AND INSTALLATION OF AN ARTERIAL
More informationC5C Cross-Connect System
C5C Cross-Connect System I N S T A L L A T I O N I N S T R U C T I O N High-Density Connection Blocks 1.0 General Product Information The C5C cross-connect system is comprised of a high-density connection
More informationPAR+ & MSC+ Controller. Installation Manual
PAR+ & MSC+ Controller Installation Manual Contents Introduction... 1 System Configuration...1 Parts List and Tools Required for Installation...1 Installation Checklist...1 Mount Controller Pedestal on
More informationMICHIGAN DEPARTMENT OF TRANSPORTATION
MICHIGAN DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION FOR GROUNDING, BONDING, LIGHTNING PROTECTION AND SURGE PROTECTION FOR INTELLIGENT TRANSPORTATION SYSTEM EQUIPMENT ITS:CLC 1 of 6 APPR:MDW:JVG:06-08-18
More informationGround Power Modules. And Accessories For Healthcare Facilities. Technical Bulletin NAE /
2 Ground Power Modules And Accessories For Healthcare Facilities Technical Bulletin NAE2092320 / 10.2011 Ground Power Modules Hospital grade outlet modules Introduction BENDER series GPM ground and power
More informationNavigator II INstallatIoN MaNUal For static and PaN/tIlt configurations
Navigator II Installation MANUAL For Static and Pan/Tilt Configurations Document Number: 432-0001-00-12, rev 100 FLIR Systems, Inc., 2008. All rights reserved worldwide. No parts of this manual, in whole
More informationInstalling a Power over Ethernet injector
Installing a Power over Ethernet injector AlphaEclipse StreetSmart and RoadStar signs The instructions in this document explain how to install/replace a Power over Ethernet (PoE) injector in a StreetSmart
More informationDANGER DANGER: is used in this manual to warn of high voltages capable of causing shock, burns, or death.
Installation/Operation Manual TABLE OF CONTENTS Page UNPACKING AND INSTALLATION Unpacking and Preliminary Inspection...2, 3 Model Number...9 LOCATION CONSIDERATIONS Environment, Equipment Performance,
More informationCIB 3125 (122A) Off-Premises Range Extender. Installation Instructions. Installed By Qualified Technician Only CIB
CIB 3125 (122A) Off-Premises Range Extender Installation Instructions Installed By Qualified Technician Only CIB 3125 106793441 1992 AT&T All Rights Reserved Printed in USA Issue 3 August 1992 NOTICE Every
More informationIndoor Protected Entrance Terminal 4588 Series
Indoor Protected Entrance Terminal 4588 Series Instructions Underwriters Laboratories (UL) Listed September 2003 78-8135-1209-8-A 1.0 General The 3M Indoor Protected Entrance Terminal (PET) 4588 Series
More informationPREVENTING DOWNTIME OF E911 CENTERS
P O W E R V A R White Paper # 600 PREVENTING DOWNTIME OF E911 CENTERS 1 4 5 0 L a k e s i d e D r i v e, Wa u k e g a n, I l l i n o i s 6 0 0 8 5 t e l e p h o n e : 8 4 7-5 9 6-7 0 0 0 f a x : 8 4 7-5
More informationHP UPS R/T3000 G2. Overview. Precautions. Kit contents. Installation Instructions
HP UPS R/T3000 G2 Installation Instructions Overview The HP UPS R/T3000 G2 features a 2U rack-mount with convertible tower design and offers power protection for loads up to a maximum of 3300 VA/3000 W
More informationSERVICE MANUAL MODEL WPP-331-D WEATHERPROOF TELEPHONE MODEL HOB-331-D WEATHER RESISTANT TELEPHONE. and MODEL SSP-311-D STAINLESS STEEL PANEL TELEPHONE
WPP(HOB)-331-D or SSP-311-D ATD-11 Issue 5.00 SERVICE MANUAL FOR MODEL WPP-331-D WEATHERPROOF TELEPHONE MODEL HOB-331-D WEATHER RESISTANT TELEPHONE and MODEL SSP-311-D STAINLESS STEEL PANEL TELEPHONE EQUIPPED
More informationTarget Interface / Construction Compliance Inspection Checklist
A. Targets Quantities meet DD9, applicable TC -, and CEHNC Design Guide 0-- Oriented to face firing line or firing positions/points B. Roads-Service, Lanes Number of lanes meets DD 9, applicable TC -,
More informationOffice of the Chief Information Officer Technical Note: IT-960-TN14 Effective: 05/25/2006 Last Revised: 02/17/2012 Issuing Office: OCIO
Cabling Standards Office of the Chief Information Officer Technical Note: IT-960-TN14 Effective: 05/25/2006 Last Revised: 02/17/2012 Issuing Office: OCIO 1. Purpose CABLING STANDARDS This technical note
More informationSPECIAL SPECIFICATION 1864 Pole Mounted Cabinet
1993 Specifications CSJ s 0924-06-221,etc. & 0924-06-223 SPECIAL SPECIFICATION 1864 Pole Mounted Cabinet 1. Description. This specification describes the minimum acceptable requirements for a weatherproof
More informationINSTALLATION INSTRUCTIONS
TM REPLACEMENT PARTS FOR USE WITH CX SERIES PANELS INSTALLATION INSTRUCTIONS Hubbell Control Solutions 9601 Dessau Road Building One Suite 100 Austin, TX 78754 Toll Free: 888-698-3242 Fax: 512-450-1215
More informationICS Entrance Management Sign Installation Guide. Version 1.0
ICS Entrance Management Sign Installation Guide Version 1.0 Thank you for purchasing your new ICS Entrance Management System (EMS) from Innovative Control Systems, Inc. Installation Overview This document
More informationInstruction Manual. Electrical Management System (EMS) EMS-HW30C & EMS-HW50C
Instruction Manual Electrical Management System (EMS) EMS-HW30C & EMS-HW50C EMS-HW50C EMS-HW30C! CAUTION These instructions are intended to provide assistance with the installation of this product, and
More informationPXC Compact Unitary Equipment Controller (UEC)
Document No. 553-169 PXC Compact Unitary Equipment Controller (UEC) Product Description The PXC Unitary Equipment Controller (UEC) is an MS/TP device that can be configured as a programmable, stand-alone
More information3M Indoor Protected Building Entrance Terminal 4788V-QCS Series
The Network of Networks. 3M Indoor Protected Building Entrance Terminal 4788V-QCS Series with 3M Quick Connect System (QCS) 2811 Dry Flame Retardant Block for Field-Terminated Building Cables Instructions
More informationSTATE OF NEW JERSEY BUREAUS OF ITS ENGINEERING AND SAFETY & DATA DEVELOPMENT DEPARTMENT OF TRANSPORTATION TRENTON, NEW JERSEY 08625
September 2011 STATE OF NEW JERSEY BUREAUS OF ITS ENGINEERING AND SAFETY & DATA DEVELOPMENT DEPARTMENT OF TRANSPORTATION TRENTON, NEW JERSEY 08625 MATERIAL SPECIFICATIONS FOR WEIGH-IN-MOTION SYSTEM The
More information4188, 4288, 4288-S and 4688 Protected Entrance Terminals
4188, 4288, 4288-S and 4688 Protected Entrance Terminals Instructions Underwriters Laboratories (UL) Listed January 1997 34-7041-3837-8 Revision A Contents: 1.0 General... 1 2.0 Accessories... 2 3.0 Protector
More informationCisco CRS 3-Phase AC Power Distribution Unit Installation Guide 2. Cisco CRS 3-Phase AC Power Distribution Unit 2
Cisco CRS 3-Phase AC Power Distribution Unit Installation Guide Cisco CRS 3-Phase AC Power Distribution Unit Installation Guide 2 Cisco CRS 3-Phase AC Power Distribution Unit 2 Revised: November 18, 2016,
More informationVRp Three-Phase Precision AC Voltage Regulator
VRp-22500-0338 Three-Phase Precision AC Voltage Regulator INSTALLATION INSTRUCTIONS Inspection and Unpacking Please inspect the wooden crate for obvious shipping damage. Some crates contain up to six (6)
More informationTarget Interface / Construction Compliance Inspection Checklist
A. Targets Quantities meet DD9, applicable TC -, and CEHNC Design Guide 0-- Oriented to face firing line or firing positions/points B. Roads-Service, Lanes Number of lanes meets DD 9, applicable TC -,
More informationElectrical Management System (EMS) EMS-HW30C & EMS-HW50C
Electrical Management System (EMS) EMS-HW30C & EMS-HW50C Installation & Operating Guide for: Model EMS-HW30C Rated at 120V/30A and Model EMS-HW50C Rated at 240V/50A Surgio Says Lifetime Warranty on all
More informationONEAC Total Protection Installation Handbook. For Telecom Systems
ONEAC Total Protection Installation Handbook For Telecom Systems INTRODUCTION Telecom systems have changed dramatically over the last several years, evolving into Telecomputers. Compared to past technologies,
More informationTraceTek Leak Detection Master Module Installation Instructions TOOLS REQUIRED STORAGE
TTDM-128 TraceTek Leak Detection Master Module Installation Instructions TRACETEK APPROVALS AND CERTIFICATIONS TYPE NM General Signaling Equipment 76LJ GENERAL INFORMATION Please read these instructions
More informationTarget Interface / Construction Compliance Inspection Checklist
A. Targets Quantities meet DD9, applicable TC 5-, and CEHNC Design Guide 0-- Oriented to face firing line or firing positions/points B. Roads-Service, Lanes Number of lanes meets DD 9, applicable TC 5-,
More informationOutdoor PTZ. Mounting on the Ceiling Using Pendant Mount. Installation Guide. For Models: I93, I94, I95, I96, KCM /12/03
Outdoor PTZ Mounting on the Ceiling Using Pendant Mount For Models: I93, I94, I95, I96, KCM-8211 2013/12/03 Table of Contents Mounting Solutions... 3 Straight Tube Installation Procedures... 4 Step 1:
More information3M Indoor Building Entrance Terminal (IBET) 4790V and 4790VL Series
3M Indoor Building Entrance Terminal (IBET) 4790V and 4790VL Series with 3M Quick Connect System (QCS) 2811 Dry Flame-Retardant Block and RJ-11 Test Ports Instructions Underwriters Laboratories (UL 348X)
More information3M Indoor Protected Building Entrance Terminal 4588V-QCS Series
3M Indoor Protected Building Entrance Terminal 4588V-QCS Series with 3M Quick Connect System 2811 Dry Flame Retardant Block Instructions Underwriters Laboratories (UL 348X) Listed April 2010 3 78-0013-1813-4-A
More informationService Manual For. -IP Voice over Internet Protocol -ACH** Handset cord length Inches
SSP-3-F -ISSUE 4.0 Service Manual For -IP Voice over Internet Protocol -ACH** Handset cord length Inches -M Magnetic Hookswitch -CCH Coiled cord length Feet 5, 0, or 5 -BK Braille Keypad -PBVC Pushbutton
More informationElectrical Integration of PV Systems. Ridha Hamidi, Ph.D.
Electrical Integration of PV Systems Ridha Hamidi, Ph.D. 1 Many articles in the NEC are applicable to the electrical integration of a PV system, particularly Article 690. 2 The NEC defines the various
More informationModel 2460-KIT. Screw Terminal Connector Kit. Description / September 2014 *P * 1
Keithley Instruments 28775 Aurora Road Cleveland, Ohio 44139 1-800-935-5595 http://www.keithley.com Model 2460-KIT Screw Terminal Connector Kit Description The Model 2460-KIT Screw Terminal Connector Kit
More informationOverview These instructions are presented as a guideline for installing and setting up the LX Series Breaker Control Panel.
LX Breaker Control Panels Installation and Setup Procedure Hubbell Building Automation, Inc. 9601 Dessau Road Building One Suite 100 Austin, Texas 78754 512-450-1100 512-450-1215 Fax www.hubbell-automation.com
More informationHUBBELL SPIKESHIELD Wired-In Branch Panels Surge Protective Device (SPD)
HUBBELL SPIKESHIELD Wired-In Branch Panels Surge Protective Device (SPD) Instruction Bulletin 8222-0513B Retain for future use. SPIKESHIELD Wired-In Branch Panels 8222-0513B 05/2012 Table of Contents Precautions...
More informationhp uninterruptible power system r12000 xr models installation instructions
hp uninterruptible power system r000 xr models installation instructions Overview These instructions show how to install an uninterruptible power system (UPS). For detailed information about the UPS, refer
More informationComputer Network Design Guide Existing Systems 1 / 6
COMPUTER NETWORK DESIGN GUIDELINE FOR EXISTING SYSTEMS DOCUMENT NUMBER: 16765 APPLICATION: ELEMENTARY, MIDDLE AND HIGH SCHOOL DATE OF ISSUE: 11-27-06 - First Issued NOTES: The attached guideline should
More informationSERVICE MANUAL MODEL SSC-301-F (FORMERLY 301-FS) MODEL BLC-301-F (FORMERLY 301-F)
SSC-301-F OR BLC-301-F-ISSUE4.0 SERVICE MANUAL FOR MODEL SSC-301-F (FORMERLY 301-FS) OR MODEL BLC-301-F (FORMERLY 301-F) CHARGE-A-CALL TELEPHONE Serving the Telephone Industry Since 1930 Communication
More informationPowerLogic High Density Metering System 1-Meter Enclosure
PowerLogic High Density Metering System 1-Meter Enclosure Installation Guide 63230-508-211A1 Safety information PowerLogic High Density Metering System 1-Meter Enclosure Important information Read these
More informationM215 (M215-60) Safety
M215 QUICK INSTALL GUIDE M215 (M215-60) Safety Important Safety Information This document contains important instructions to use during installation and maintenance of the Enphase M215 Microinverter. To
More informationINSTALL INSTRUCTIONS RSXMR-9886-P-48
INSTALL INSTRUCTIONS RSXMR-9886-P-48 Installation Instructions RSXMR-9886-P-48 (CEQ. 20194) INSTALL INSTRUCTIONS RSXMR-9886-P-48 Contents Section Description Page 1 Copyright 2 1.1 Disclaimer 2 1.2 Warnings
More informationTarget Interface / Construction Compliance Inspection Checklist
A. Targets Date: Quantities meet DD9, applicable TC -, and CEHNC Design Guide 0-- Oriented to face firing line or firing positions/points B. Roads-Service, Lanes Number of stations meets DD 9, applicable
More information3M Add-On Terminals 4220P (100, 200, 300 & 400 pairs)
3M Add-On Terminals 4220P (100, 200, 300 & 400 pairs) Instructions August 2011 3 78-8130-2330-1-C 1.0 General 1.1 The 3M Add-On Terminals 4220P-100, 4220P-200, 4220P-300 and 4220P-400 are designed to expand
More informationM250 (M LL) Safety
M250 SAFETY M250 (M250-60-2LL) Safety Important Safety Information This document contains important instructions to use during installation of the Enphase M250 Microinverter. To reduce the risk of electrical
More informationTECHKNOW, INC. Kiosk Order Confirmation System INSTALLATION MANUAL. Revision Date: July 11, 2012 Part # Version 3.2
document Page 1 of 18 TECHKNOW, INC Kiosk Order Confirmation System INSTALLATION MANUAL Revision Date: July 11, 2012 Part # Version 3.2 Techknow, Inc. 393 Mayfield Road Duncan, SC 29334 www.gotechknow.com
More informationType DH7091 Transient Protection Assembly
Type DH7091 Transient Protection Assembly D3P00801102 Installation Manual PN4.10:DH7091 Revision A June 1991 This manual supersedes the previous issue dated February 1990. In October 2001, company logos
More information1. Carefully unpack the um260 s shipping carton and check the contents for damage.
um260 Installation Manual um260 Installation Chapter 4 um260 MICRO MONITOR INSTALLATION This section of the um260 Micro Monitor Installation Manual describes the requirements and procedures for installing
More informationSECTION N -- ELECTROSTATIC DISCHARGE (ESD)
INSTALLATION REQUIREMENTS AT&T January, 2012 Section N, ATT-TP-76300 Revised NA SECTION N -- ELECTROSTATIC DISCHARGE (ESD) CONTENTS PAGE 1. GENERAL... N-1 1.1. Introduction... N-1 1.2. General Requirements...
More informationIP Office Technical Tip
IP Office Technical Tip Tip no: 101 Release Date: 27 October 2005 Region: GLOBAL Avaya IP Office Ground Requirements This document is a quick guide of IP Office grounding requirements, based on the IP
More informationInstallation Instructions & User Manual POWERWARE TVSS ZONESENTINEL. AC Panel Transient Voltage Surge Suppressors
Installation Instructions & User Manual POWERWARE TVSS ZONESENTINEL AC Panel Transient Voltage Surge Suppressors INTRODUCTION This document explains how to install the Powerware TVSS ZoneSentinel AC Panel
More informationInstallation NOTICE. S&C IntelliCap Automatic Capacitor Control. Table of Contents. Instruction Sheet
S&C IntelliCap Automatic Capacitor Control Installation Table of Contents Section Page Section Page Introduction Qualified Persons.... 2 Read this Instruction Sheet.... 2 Retain this Instruction Sheet...
More informationTemperature. Power requirements. Weight. Dimensions
Installing the Tracer Summit BMTX Building Control Unit Ordering numbers: BMTX001AAB000, BMTX001AAB010, BMTX001AAB001, BMTX001AAB011, BMTX001BAB000, BMTX001BAB010, BMTX001BAB001, BMTX001BAB011, BMTX001DAB000
More informationInstalling And Programming The Analog Terminal Interface On The DXP, DXP Plus, and FX Series Digital Communications Systems
R Installing And Programming The Analog Terminal Interface On The DXP, DXP Plus, and FX Series Digital Communications Systems The Analog Terminal Interface The ATI-D-1PT is a multipurpose, on-premise accessory
More informationMeter Enclosure and Equipment Standards
Meter Enclosure and Equipment Standards (a) (b) General Requirements: CITY OF OCALA UTILITY SERVICES METER ENCLOSURE AND EQUIPMENT STANDARDS: (1) To avoid the costs associated with having to replace unacceptable
More informationSERVICE MANUAL MODEL SSW-321-F MODEL BLW-321-F
SSW-321-F OR BLW-321-F-ISSUE4.0 SERVICE MANUAL FOR MODEL SSW-321-F OR MODEL BLW-321-F MINI WALL TELEPHONE Serving the Telephone Industry Since 1930 Communication Equipment 519 W South Park Street & Engineering
More information7" Touch Screen Display
7" Touch Screen Display Installation Guide Contents Minimum Requirements...1 Select a Location...1 Initial Setup...2 Unboxing...2 Installation...3 Prepare the Panel...3 Install the Mounting Plate...3 Mount
More informationThis Datasheet for the IC670GBI002 24VDC BUS INTERFACE UNIT.
This Datasheet for the IC670GBI002 24VDC BUS INTERFACE UNIT http://www.qualitrol.com/shop/p-14508-ic670gbi002.aspx Provides the wiring diagrams and installation guidelines for this GE Field Control module.
More informationPower Supply and Fan Module Installation
3 CHAPTER This chapter describes how to remove and install a new or replacement power supply or fan module in a Catalyst 3750-E or Catalyst 3560-E switch. See these sections: Installation Overview, page
More informationIntelliBrite Controller (For IntelliBrite Pool, Spa and Landscape Lighting Fixtures)
IntelliBrite Controller (For IntelliBrite Pool, Spa and Landscape Lighting Fixtures) Installation and User s Guide IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS
More informationR-LB R-LX Series Installation, Operation & Maintenance Manual
Installation, Operation & Maintenance Manual WARNINGS Safety First Hazardous Voltage & Shock Hazard Only qualified licensed electricians should install or service SPDs Hazardous voltages exist within SPDs
More informationSERVICE MANUAL MODEL SSW-321-X
SSW-321-X-ISSUE 4.0 SERVICE MANUAL FOR MODEL SSW-321-X STAINLESS STEEL WALL TELEPHONE Serving the Telephone Industry Since 1930 Communication Equipment 519 W South Park Street & Engineering Company Okeechobee,
More informationM215 Safety (M LL-S22-IG / S23-IG / S24-IG)
M215 SAFETY M215 Safety (M215-60-2LL-S22-IG / S23-IG / S24-IG) Important Safety Information This document contains important instructions to use during installation of the Enphase M215 Microinverter. To
More informationObtaining Documentation and Submitting a Service Request, page xvii Safety Warnings, page xvii Safety Guidelines, page xx
Preface Obtaining Documentation and Submitting a Service Request, page xvii Safety s, page xvii Safety Guidelines, page xx Obtaining Documentation and Submitting a Service Request For information on obtaining
More informationAL168 Series Multi-Output Power Supplies
AL168 Series Multi- Power Supplies Installation Guide Models Include: AL168CB - 16VAC @ 6A (100VA) or 18VAC @ 5.5A (100VA). AL168175CB - 16VAC @ 10A (175VA). AL168300CB - 16VAC @ 18A (350VA) or 18VAC @
More informationPower Supply, 17-inch
apple imac G5 Power Supply, 17-inch Replacement Instructions Follow the instructions in this sheet carefully. Failure to follow these instructions could damage your equipment and void its warranty. Note:
More informationSERVICE MANUAL FOR MODEL SSC-500-F (FORMERLY 501-FSZ) STAINLESS STEEL HANDS FREE CHARGE-A-CALL TELEPHONE EQUIPPED WITH LOW-POWER SPEAKER BOARD
SSC-500-F-(501-FSZ)-ISSUE4.0 SERVICE MANUAL FOR MODEL SSC-500-F (FORMERLY 501-FSZ) STAINLESS STEEL HANDS FREE CHARGE-A-CALL TELEPHONE EQUIPPED WITH LOW-POWER SPEAKER BOARD Serving the Telephone Industry
More informationIntelliBrite Controller (For IntelliBrite Pool, Spa and Landscape Lighting Fixtures) Installation and User s Guide
IntelliBrite Controller (For IntelliBrite Pool, Spa and Landscape Lighting Fixtures) Installation and User s Guide *619751* P/N 619751 - Rev B IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS
More informationOutdoor Risk and Equipment Protection
Outdoor Risk and Equipment Protection The proper use of surge suppressors, lightening arrestors, and weatherproof enclosures are critical protection measures for all outdoor wireless and IP video devices.
More informationModel DMX8DIM Installation and Operations Manual
Model DMX8DIM Installation and Operations Manual Doug Fleenor Design, Inc. 396 Corbett Canyon Road Arroyo Grande, CA 93420 (805) 481-9599 Voice and FAX Manual revision June, 2018 Product description The
More informationSYSTIMAX 360 PATCHMAX Modular Panel Instructions
Issue 1, February 2015 SYSTIMAX 360 PATCHMAX Modular Panel Instructions General The SYSTIMAX 360 PATCHMAX modular panel can be used for both EIA-T568A or EIA-T568B wiring applications and is an approved
More informationInstallation and Operation Manual
Installation and Operation Manual APC 2X Series Hardwire Products PMP2X-A PMF2X-A PMG2X-A PMH2X-A APC hardwired products are designed to provide specification-grade performance at the service entrance,
More informationELECTRO-MECH SCOREBOARD CO.
ELECTRO-MECH SCOREBOARD CO. MODEL 2150 SHOT TIMER OWNER S HANDBOOK Thank you for choosing an Electro-Mech Scoreboard for your athletic complex. We are confident that your new shot timer will give many
More informationSERVICE MANUAL MODEL SSC-303-D (FORMERLY 303-DS)
SSC-303-D(303DS)-ADI2.01-650-541-ISSUE4.0 SERVICE MANUAL FOR MODEL SSC-303-D (FORMERLY 303-DS) STAINLESS STEEL AUTOMATIC DIALING TELEPHONE EQUIPPED WITH ADI2.01 FIMWARE Serving the Telephone Industry Since
More informationInstalling And Programming The Off-Premise Extension Interface On The Digital Communications System
R Installing And Programming The Off-Premise Extension Interface On The Digital Communications System 1.0 Introducing The Off-Premise Extension Interface This publication describes the features, applications,
More informationHow to hardwire the Olympus D-370 and D-380 Digital Cameras
How to hardwire the Olympus D-370 and D-380 Digital Cameras Copyright, PixController http://www.pixcontroller.com, all rights reserved. This document covers in detail how to modify either the Olympus D-370
More informationM215-Z Safety Information (M LL-IG-ZC)
M215-Z SAFETY M215-Z Safety Information (M215-60-2LL-IG-ZC) This document contains important instructions to use during installation of the M215-Z Zep Compatible Microinverters. To reduce the risk of electrical
More informationInstruction Manual: IM E
Innovative Technology TVSS Products The I.T. Equalizer Installation Instruction Manual: IM01005011E Rev. 2 May 2009 Contents Page 1 Introduction... 1 1.1 Scope... 1 1.2 I.T. Equalizer Catalog Numbering
More informationThis Datasheet for the IC697CHS790. Rack, 9 Slots, Rear Mount.
This Datasheet for the IC697CHS790 Rack, 9 Slots, Rear Mount. http://www.cimtecautomation.com/parts/p-14771-ic697chs790.aspx Provides the wiring diagrams and installation guidelines for this GE Series
More informationSpecifications, Installation, and Operating Instructions
Specifications, Installation, and Operating Instructions Model: Power Vantage AC Panel Protector CAUTION: The installation of a surge protection device () must be done by qualified electrical personnel.
More informationTreadmill Integrated LCD Screen Option. Cardio Theater Integrated Bracket Assembly Instructions
Treadmill Integrated LCD Screen Option Cardio Theater Integrated Bracket Assembly Instructions Table of Contents 1 2 3 4 5 6 Before You Begin... 4 Obtaining Service... 4 Unpacking the Equipment... 4 Important
More informationTotal Protection Solutions Surge Protective Devices SurgeTrack Series: 080, 120, 160, 240, 300 and 400
Total Protection Solutions SurgeTrack Series: 080, 120, 160, 240, 300 and 400 Surge Protective Devices Installation, Operation and Maintenance Manual SURGETRACK INSTALLATION, OPERATION AND MAINTENANCE
More informationPARTNER Contact Closure Adjunct
Closure Installation Instructions BEFORE STARTING INSTALLATION, READ AND UNDERSTAND ALL SAFETY INSTRUCTIONS ON PAGE. The is used with a Advanced Communications System processor module (available separately)
More informationModular Terminal Blocks and Terminal Strips with CAGE CLAMP, Series 260 to 262, Side-Entry
36 Modular Terminal Blocks and Terminal Strips with CAGE CLAMP, Series 260 to 262, Side-Entry Assembly Assembly of modular terminal blocks to terminal strips Mounting of an end plate screw fixing CAGE
More informationEnphase S-Series Microinverter and Engage Cable Safety
SAFETY Enphase S-Series Microinverter and Engage Cable Safety Important Safety Information (S280-60-LL and S230-60-LL) This document contains important instructions to use during installation of the Enphase
More informationPLC Racks IC697CHS782/783
5 1 PLC Racks IC697CHS782/783 (IC697CHS782/783) datasheet Features Accepts 3rd Party VME modules which require 0.8 spacing. Accepts all IC697 PLC module types. Rear mount rack mounts in a 10 (254 mm) deep
More informationPACSystems RX7i IC698CHS009/119
January 2010 The RX7i rack can be used for all RX7i CPU and I/O configurations, Series 90-70 I/O, and VME modules. Backplane connectors are spaced on 0.8" (20.3mm) centers to accommodate single-width RX7i
More informationSuperBus 2000 Phone Interface/Voice Module Installation Instructions
SuperBus 2000 Module Installation Instructions Product summary The SuperBus 2000 (PIV) Module provides phone and voice functions for the Concord, Concord 4, and Concord Express (v4) panels. The PIV module
More informationInstalling and Setting Up the Components
Chapter 3 Installing and Setting Up the Components This section of the AKC 55 manual will explain, for each network component: (1) Description and Identification (5) Network connections (2) Mounting (6)
More informationModel HM-535 Power Supply Installation and Service Instructions
Model HM-535 Power Supply Installation and Service Instructions 430-535 0104 2004 Heritage MedCall, Inc SENTRY INSTALLATION & SERVICE INSTRUCTIONS POWER SUPPLY UNIT Model HM-535 IMPORTANT SAFETY INSTRUCTIONS
More informationHP R/T2200 UPS. Overview. Precautions. Installation Instructions. The HP UPS R/T2200 features power protection for loads up to 2200 VA/1600 W.
HP R/T2200 UPS Installation Instructions Overview The HP UPS R/T2200 features power protection for loads up to 2200 VA/1600 W. For more information about any of the topics covered in this document, see
More informationSAVE THESE INSTRUCTIONS
OUTDOOR HARDWIRE INSTALLATION INSTRUCTIONS Please read and save these instructions. Read carefully before using product. Protect yourself and others by observing all safety information, warnings and cautions.
More information4888 and 4988 Outdoor Protected Entrance Terminals
4888 and 4988 Outdoor Protected Entrance Terminals Underwriters Laboratories (UL) Listed Instructions January 1997 34-7031-7272-5 Revision C Contents: 1.0 General... 1 2.0 Accessories... 2 3.0 Protector
More informationSERVICE MANUAL MODEL SSW-521-D2-ADA
SSW-521-D2-ADA-SPK1.07UNVLr3-ADA-ISSUE4.0 SERVICE MANUAL FOR MODEL SSW-521-D2-ADA STAINLESS STEEL HANDS FREE WALL TELEPHONE WITH OPTIONAL ADA FEATURE AND OPTIONAL SECOND-NUMBER AUTO-DIAL FEATURE EQUIPPED
More informationSERVICE MANUAL MODEL SSW-520-F
SSW-520-F-ISSUE4.0 SERVICE MANUAL FOR MODEL SSW-520-F HANDS FREE STAINLESS STEEL TELEPHONE EQUIPPED WITH LOW POWER SPEAKER BOARD Serving the Telephone Industry Since 1930 Communication Equipment 519 West
More informationEmery County Senior Center Green River 06/07
SECTION 262726 - WIRING DEVICES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification Sections,
More information