Industrial Control Panels Tested product combinations to meet NEC Article 409 and UL 508A Standard

Size: px
Start display at page:

Download "Industrial Control Panels Tested product combinations to meet NEC Article 409 and UL 508A Standard"

Transcription

1 Industrial Control Panels Tested product combinations to meet NEC Article 409 and UL 508A Standard

2 Short circuit current ratings and the new NEC Article 409 The 2005 Edition of the National Electrical Code, NFPA 70 contains a new Article 409 entitled Industrial Control Panels. This article provides installer and enforcement authorities with the minimum requirements to facilitate the safe installation and inspection of industrial control panels. The requirement is that the components of the electrical power circuit meet a defined Short Circuit Current Rating (SCCR) for the application and that the panel is marked with the appropriate SCCR. A device marked with an interrupt rating or withstanding rating is considered to be the SCCR rating for the device. On April 25, 2006, Underwriters Laboratories Inc. began enforcing the Supplement SB of the Standard for Industrial Control Panels, UL 508A. This new addition to the standard is the only approved method for determining the SCCR of an industrial control panel. How do I obtain the needed SCCR? You have three options for determining the SCCR for the industrial control panel: 1. Test each panel construction and record the construction in the follow-up procedure. With the multitude of possible product combinations within a panel, this option can require a lot of testing and maintenance. Thirdparty testing and certification may also be required. 2. Purchase previously tested constructions (tested combinations) from a major supplier of equipment that can be tabulated in the control or machine panel builder s procedure. Once you have all the component ratings, either utilize an outside service or UL 508A, Supplement SB. 3. Utilize method described by Underwriters Laboratories Inc. in their UL 508A, Supplement SB. What are tested combinations? Tested combinations from Schneider Electric offer control panel builders, machine panel builders and end customers, such as facility engineers and managers, the ability to simplify this process significantly. Typical branch circuits as tested combinations Multiple products become one component as a tested combination (shown with 480V SCCR) Higher level SCCRs can be achieved through the use of UL-approved product combinations. This can represent several types of components used in a power circuit of an industrial control panel. This combination has been previously tested for a short circuit rating and can be applied to obtain the highest rating possible for a control panel s branch circuit versus individual component ratings. Common examples would be motor circuit protection and motor control devices. Schneider Electric posts its approved tested combinations along with the UL identification number on our website, *Note: See page 5 for details on drive SCCRs IEC NEMA DRIVE* 2

3 Advantages of tested combinations Tested combinations provide the opportunity to achieve higher level SCCR than individual component ratings. Schneider Electric products are submitted to UL for testing as a standard part of our rating application. Combined as a unit or group, the results are not calculated or derived; they are physically tested to ensure that they meet the SCCR that is approved. One of the challenges facing panel builders or facility engineers is that in the past, intermixing of power circuit components has been commonplace. Under the new NEC Article 409 requirement, this practice is discouraged it is impossible to obtain higher level short circuit ratings as these products have never been laboratory tested in combination before. The end result is that the power circuit SCCR will be much lower than desired as the application of UL 508A, Supplement SB will reveal that the weakest link, such as a terminal block, may drag down the system rating. Intermixing power circuit components from various brands can also create lower SCCR values. Schneider Electric s tested and UL-approved ratings offer a quicker solution to achieving the ratings goal you seek. Manufacturer-provided tested combinations allow panel and machine builders to obtain higher SCCRs for branch circuits. Combined with the UL ID or identification number, the results are validated by UL to support your SCCR rating helping to mitigate issues that may surface during design phases or a later inspection during installation. The ID reference for each branch circuit makes inspection and listing easy. How do you obtain high fault rated branch circuit SCCRs? Circuit Breaker Contactor Overload Relay Historically, industrial control panels mix many types of components with various SCCR ratings inside the panel. The SCCR requirements in the 2005 NEC Article 409 and Supplement SB of UL 508A place stringent requirements on the ratings of each component inside the panel s power circuit. From an application perspective, the branch circuit has undergone a number of changes with the new code and standard. As you can see in the diagram, the area outlined in green is an example tested combination as a part of a motor control branch circuit. The SCCR is approved by UL and has a stand alone rating allowing for branch protection with starters, contactors and motor controllers along with high fault levels. Understanding what affects your SCCR evaluations There are a number of factors that can affect how your SCCR rating is derived. The following components are typically found in the power circuit of a control panel and should be included in your SCCR evaluation. Circuit Breakers Contactors Drives Fuses IEC Contactors Lighting Contactors Manual Motor Controllers Meter Sockets NEMA Contactors Receptacles Switch Units Terminal Blocks Transformers Devices used downstream of a control transformer tapped from the feeder circuit are not included in the calculation of the control panel SCCR. Do not include in your evaluation the following equipment as these devices are not typically found in your power circuits: Automation Devices Indicator Lights Limit Switches Push Buttons Relays Timers Unless otherwise modified by Supplement SB SB4.3, your panel is required to use the lowest level component SCCR in your power circuit. The table on page four from the UL 508A Supplement SB lists the ratings of common unmarked components and their default SCCR rating unless you have an alternative, such as a tested combination from Schneider Electric. 3

4 How to maintain high SCCRs using distribution and terminal blocks Power distribution and terminal blocks have default values of 10kA in the new UL 508A Standard, Supplement SB, Table SB4.1. Some manufacturers have now tested their products for various ratings and received approvals. Check with the specific supplier for details. Another alternative is to eliminate the need for a distribution block in a feeder circuit. This can be accomplished by directly connecting to our circuit breakers using our power distribution lugs that are approved for the short circuit rating of the breaker. This also helps to eliminate a component from the design. To maintain high SCCR levels, we recommend elimination of terminal blocks and utilize direct connections where possible to motors and other key circuits. This helps to avoid the standard default values in the UL 508A, Supplement SB, until such time as the manufacturers of these products obtain higher ratings for power circuit usage. Be wary of fuse performance claims vs. circuit breakers and tested combinations Some fuse manufacturers are claiming that you should replace circuit protection devices such as a circuit breaker with a fuse in order to comply with SCCR requirements. This is an incorrect statement. We offer a variety of tested and UL-approved combinations to meet and exceed most requirements in control panels. Another key fact to remember is that fuses cannot be used as a part of a tested combination unless they are tested as such, and individually listed with the manufacturer and UL. Direct substitution is not recommended. Fuses cannot provide the convenience and reset capability that you can obtain by using Schneider Electric s circuit protection components. Also, for added safety, there is no need to replace a breaker when it trips, further enhancing the safety of the employee in a powered equipment environment. The table below is extracted from the UL 508A Supplement SB, Table SB4.1 and is meant to be used as a guide only. Please refer to the UL website to view the most up-to-date Table SB4.1 information. Extract of Data from UL 508A Table SB4.1 Assumed maximum short circuit current rating for unmarked components (Eff. April 25, 2006) Component SCCR, ka Bus bars 10 Circuit breakers (including GFCI type) 5 Current meters * Fuseholder 10 Industrial control equipment a. Auxiliary devices (overload relay) 5 b. Switches (other than mercury tube type) 5 c. Mercury tube switches - Rated over 60 amperes or over 250V 5 - Rated 250 volts or less, 60 amperes or less, and over 2 kva Rated 250 volts or less and 2 kva or less 1 Motor controller, rated in horsepower (kw)*** a (0-37.3) 5*** b (38-149) 10*** c ( ) 18*** d ( ) 30*** e ( ) 42*** f ( ) 85*** Meter socket base 10 Miniature or miscellaneous fuse 10** Receptacle (GFCI type) 2 Receptacle (other than GFCI type) 10 Supplementary protector 0.2 Switch unit 5 Terminal block or power distribution block 10 * A short circuit current rating is not required when connected via a current transformer or current shunt. A directly connected current meter shall have a marked short circuit current rating ** The use of a miniature fuse is limited to 125-volt circuits *** Standard fault current rating for motor controller rated within specified horsepower range With the permission of Underwriters Laboratories Inc., material is reproduced from UL Standard 508A, Standard For Industrial Control Panels, which is copyrighted by Underwriters Laboratories, Inc., 333 Pfingsten Road, Northbrook Illinois UL shall not be responsible to anyone for the use of or reliance upon a UL Standard by anyone. UL shall not incur any obligation or liability for damages, including consequential damages, arising out of or in connection with the use, interpretation of, or reliance upon a UL Standard. UL s Standards for Safety are copyrighted by UL. Neither a printed copy of a Standard, nor the file for an electronic version of a Standard may copied, reproduced, and/or altered in any way. All of UL s Standards and all copyrights, ownerships, and rights regarding those Standards shall remain the sole and exclusive property of UL. Revisions of UL Standards for Safety are issued from time to time. A UL Standard for Safety is current only if it incorporates the most recently adopted revisions. Copies of the current edition of UL (Standard Number) may be purchased from: comm Brook Drive Downers Grove, IL USA in U.S. and Canada outside the U.S. and Canada Fax: in U.S. and Canada Fax: outside the U.S. and Canada 4

5 Current limiting provision in the UL 508A Standard Within the Supplement SB, you can modify a panel rating using approved current limiting feeder components. What this means is that transformers, circuit breakers and fuses can help you obtain high SCCRs when lower fault components are specified in the design. As stated below, circuit breakers can provide this capability. According to the UL 508A SB4.3.2 For branch circuits supplied by a listed circuit breaker marked current limiting in the feeder circuit, the short circuit current rating on the line side of the circuit breaker shall be one of the following: a) The short circuit current rating of the feeder circuit breaker, when all of the components in the branch circuit have a short circuit current rating not less than the published peak let-through current of the circuit breaker, see Figure SB4.1, and the short circuit current rating of all branch circuit protective devices on the load side are not less than the short circuit current rating of the feeder circuit breaker; b) The smallest short circuit current rating of any branch circuit protective device on the load side of the feeder circuit breaker, when the conditions of SB4.3.2(a) exist except the short circuit current rating of the branch circuit protective devices on the load side are less than the short circuit current rating of the feeder circuit breaker; c) The smallest short circuit current rating of any branch circuit on the load side of the feeder circuit breaker, when the conditions of SB4.3.2(a) or SB4.3.2(b) are not met. As you can see above, current limiting breakers from Schneider Electric can supplant the need for a current limiting fuse. In order to utilize the current limiting approach, your application design must meet the specifics of SB4.3.2 or SB As highlighted above in bold print, simply inserting current limiting provisions will not elevate your panel s overall SCCR value. In order to do that, you must insure that your branch overcurrent protective devices or tested combination have an SCCR that is equal to or greater than the current limiting device employed in the feeder circuit. Otherwise, you will be limited to the lowest SCCR of your branch devices. Short circuit ratings and options for motor circuits The following table can help you select the appropriate mix of product combinations to meet your control panel requirements. As you can see, the variety of breakers, starters and relays offered by Schneider Electric can meet most SCCR application demands. Breaker + MC + OLR Manual Starter and Protector U-Line Circuit Protection Powerpact MCP Powerpact UL 489 Powerpact MCP GV2/3 Group Mount GV2P GV3M GV7 Self-protected Contactor NEMA 1 to 5 NEMA 1 to 5 IEC D-Line D-Line D-Line U-line Overload Relay NEMA NEMA IEC Included Included Included Included Max Hp 10 Hp 40 Hp 10 Hp 7.5 Hp* 20 Hp 10 Hp Hp Range Hp 40 Hp 60 Hp 10 Hp 7.5 Hp* 20 Hp 75 Hp 10 Hp Hp 75 Hp 125 Hp 20 Hp 15 Hp* 40 Hp 150 Hp 20 Hp Hp 100 Hp 125 Hp 30 Hp 60 Hp 200 Hp 25 Hp SCCR 25kA-100kA 14kA-100kA 25kA-100kA 10kA-50kA 10kA-100kA 10kA-22kA 25kA-65kA 42kA-130kA Strength NEMA design Robust design High SCCR Lowest cost for Low cost Low cost Low cost Small size High SCCRs Precise motor multiple motor loads Low Hp Moderte Hp High Hp Precise control Flexible Flexible protection * 480/277V Variable Frequency Drives and Softstarts Underwriters Laboratories does not currently have a UL 508A category that recognizes a tested product combination that includes a variable frequency drive and a branch circuit protective device. While both have SCCR ratings as stand alone products, there is currently no category for a tested combination with either a circuit breaker or fuse device. If your installation requires the use of these products you must use the VFD manual to determine the overcurrent protective device required and its associated SCCR. 5

6 Motor circuit protectors and high short circuit current ratings If you need high fault levels up to 100 ka when using either IEC or NEMA style starters, the Square D Powerpact Motor Circuit Protector (MCP) from Schneider Electric may be your solution. It is the ultimate solution for flexibility, code compliance and performance for protecting motor circuits. The new Powerpact MCP offers simple solutions that deliver more reliable start-ups, better protection for your equipment, and complete adjustment range for your motor starters. Key features and attributes include: Settings for standard or energy efficient motors More reliable start-ups of your equipment Easier installations High SCCR ratings Better equipment protection and safety Lower life cycle costs To learn more about this unique product and design, visit our website at Schneider Electric tested combination solutions and UL approval Schneider Electric has been working with Underwriters Laboratories to obtain tested combinations that are more than manufacturer endorsed, but physically tested and proven to work in the environment in which we recommend. Our UL-approved tested combinations have their own UL record number to provide you with the data required to support your panel and any subsequent inspection. You can find these approved and tested combinations on our website at as you search our database. Don t be fooled with claims that combination SCCRs are not validated or approved by UL. The field approval of your panel may be jeopardized by taking shortcuts with untested product mixes. You can be sure that Schneider Electric has you covered with our tested combination testing program. Key attributes to note when using tested combinations When you use a tested combination within your control panel, it is important to note a few key database attributes in both the design and labeling phases. First, on the UL and SCCR databases, you ll note several key conditions of use in the SCCR report. The first is the Enclosure Volume value. This is a minimum volume as determined through the physical testing process. Choosing an overall enclosure volume smaller than this cubic foot rating would put you in violation of the UL category as this dimension minimum is required to assure a safe operation should there be any type of fault current incident. UL 508A, Supplement SB does not specifically address other key control panel attributes, such as latch types, NEMA vs. IEC enclosures, environmental concerns, etc. as those specifics are presented within other areas of UL 508A and other UL Standards, such as UL 50. Please consult with UL s guidelines via their website for more specifics. Another key attribute to note is the UL identification or UL ID number. This number should be placed on the final drawings and SCCR label, if possible, as a reference to the inspector as to where they can find specific information on this tested combination of products from Schneider Electric. In our online SCCR database, each tested combination has a unique UL ID number. This could be for something as minor as a voltage or horsepower rating variance from another similar combination. Please make sure to cite this UL ID number on your finished documentation and label. 6

7 Using the Schneider Electric Internet Databases for SCCR searches Schneider Electric has created a special website to help customers understand the significant impact the changes in the 2005 National Electrical Code and Underwriters Laboratories product standards will have on their business. Whether you are an industrial control manufacturer, panel or machine builder or an individual business looking to modify existing panels or learn what you need to know before buying a new one, the code and standards changes may affect your installation. This website hosts a number of education and product search tools. Some of the key pieces of information on our site include: General code and standard information NEC adoption map that is interactive so you can search a state s code requirements Steps on how to establish a short circuit current rating Schneider Electric Square D, Telemecanique and Merlin Gerin brand product SCCRs are available in searchable online databases as both individual products and in tested combinations Online training Extensive FAQs, updates, literature and much more Visit website to obtain more information on our SCCR data. Additional assistance for product combinations not listed in SCCR databases If you are unable to locate through our website or the UL database approved Schneider Electric tested combinations for our Square D, Telemecanique and Merlin Gerin brand products, please contact us via our website at and select the Contact Us option to us your questions or you may call directly during our extended Customer Service contact hours of 7 AM - 8 PM (Eastern Time) at Our tested combination database is a living environment where periodic updates and speciality combinations are being uploaded regularly. However, our product development teams can assist you in determining how to help meet your special need if our tested product combinations do not. 7

8 Schneider Electric North America Operating Division 1415 S. Roselle Road Palatine, IL Tel: Fax: BR Schneider Electric All rights reserved jc

Understanding SCCR. THE BEST ELECTRICAL CONTROLS BUSINESS ON THE PLANET! Unmatched Service Superior Product Quality Advantage Pricing

Understanding SCCR. THE BEST ELECTRICAL CONTROLS BUSINESS ON THE PLANET! Unmatched Service Superior Product Quality Advantage Pricing Understanding SCCR What is SCCR? When it comes to industrial machinery, it s critical to ensure that electrical panels are designed and built with the proper SCCR to maintain the system, eliminate downtime

More information

UL 508 A standard-compliant design of industrial control panel

UL 508 A standard-compliant design of industrial control panel UL 508 A standard-compliant design of industrial control panel Axel Jöhnke System Architecture Expert 14-15 SEPTEMBER 2011, MUNICH Agenda www.infoplc.net Origin and Comprehension Organizations Certificates

More information

UL 508A Industrial Control Panels Eaton. All Rights Reserved.

UL 508A Industrial Control Panels Eaton. All Rights Reserved. UL 508A Industrial Control Panels Objectives Who is UL? UL508A Origin Current emphasis on UL508A What is the UL 508A Standard? Implementation of the Standard Component Selection Short Circuit Current Ratings

More information

NEMA Standards Publication AB Establishing Levels of Selective Coordination for Low Voltage Circuit Breakers

NEMA Standards Publication AB Establishing Levels of Selective Coordination for Low Voltage Circuit Breakers NEMA Standards Publication AB 5-2011 Establishing Levels of Selective Coordination for Low Voltage Circuit Breakers Published by: National Electrical Manufacturers Association 1300 North 17th Street, Suite

More information

UL508Afor Panel Builders Getting Started

UL508Afor Panel Builders Getting Started UL508Afor Panel Builders Getting Started Restricted Siemens AG 2016 siemens.tld/keyword Exclusion of Liability The typical circuit diagrams and interpretations of the standard are not binding and do not

More information

Applying branch circuit breakers and supplementary protectors in North America

Applying branch circuit breakers and supplementary protectors in North America Product Application AP01102005E WMZT WMZS Applying branch circuit breakers and supplementary protectors in North America Introduction Eaton offers two types of miniature circuit breakers for use in North

More information

Equipment Short-Circuit Current Rating and Available Fault Current

Equipment Short-Circuit Current Rating and Available Fault Current Equipment Short-Circuit Current Rating and Available Fault Current Dan Neeser Field Application Engineer Eaton s Bussmann Business Dan.Neeser@CooperIndustries.com Agenda Interrupting Rating & Series Rating

More information

SECTION (16410) - ENCLOSED SWITCHES AND CIRCUIT BREAKERS

SECTION (16410) - ENCLOSED SWITCHES AND CIRCUIT BREAKERS SECTION 26 28 16 (16410) - ENCLOSED SWITCHES AND CIRCUIT BREAKERS PART 1 GENERAL 1.01 SUMMARY A. Section Includes: 1. Individually Mounted Switches and Circuit Breakers Used for the following: a. Service

More information

Requirements for machine approval in North America under the new NEC 2017

Requirements for machine approval in North America under the new NEC 2017 Requirements for machine approval in North America under the new NEC 2017 2 Rittal NEC 2017 The NEC 2017 introduces increased requirements for SCCR Rittal has long been prepared Rittal always responds

More information

Applying branch circuit breakers and supplementary protectors in North America

Applying branch circuit breakers and supplementary protectors in North America Supersedes June 2017 FAZ-NA-L FAZ-NA FAZ Applying branch circuit breakers and supplementary protectors in North America Introduction Eaton offers three types of miniature circuit breakers for use in North

More information

Short Circuit Current Ratings and AC Drives

Short Circuit Current Ratings and AC Drives Short Circuit Current Ratings and AC Drives Ivan Spronk, Product Marketing AC Drives Schneider Electric Industry NOW Express Goal of this session Understand Importance of proper SCCRs Hot button points

More information

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS SECTION 262816 - ENCLOSED SWITCHES AND CIRCUIT BREAKERS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division

More information

1510 MOTOR CONTROLLERS

1510 MOTOR CONTROLLERS SECTION 262913- MOTOR CONTROLLERS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of contract, including general and supplementary conditions and Division 1 specification section,

More information

OVERLOAD RELAYS POWER & ACTUATION PROVEN. series

OVERLOAD RELAYS POWER & ACTUATION PROVEN. series POWER & ACTUATION OVERLOAD RELAYS series Need reliable, accurate overload and phase-loss protection for your motors? c3controls Series Bimetallic Overload Relays provide unmatched protection and can be

More information

DIVISION 16 SECTION Surge Protective Device Submittal (SPD)

DIVISION 16 SECTION Surge Protective Device Submittal (SPD) DIVISION 16 SECTION 16289 Surge Protective Device Submittal (SPD) PART 1 -GENERAL 1.1 RELATED DOCUMENTS A. General: Drawings and general provisions of the Contract, including General and Supplementary

More information

.2 Section General Commissioning (Cx) Requirements. .3 Section Common Work Requirements - Electrical

.2 Section General Commissioning (Cx) Requirements. .3 Section Common Work Requirements - Electrical Issued for Review Section 26 28 16.01 Air Circuit Breakers Page 1 of 7 PART 1 GENERAL 1.1 GENERAL.1 This specification serves to define requirements for a replacement of low voltage circuit breaker of

More information

PowerFlex 400 AC Drive Guide Specification

PowerFlex 400 AC Drive Guide Specification PowerFlex 400 AC Drive Guide Specification Adjustable Frequency Drives with Bypass 3.0 50HP @ 208V AC 3.0 350HP @ 480V AC PART 1 GENERAL 1.01 Quality Assurance A. The manufacturer shall have minimum 5

More information

24973 Circuit Breaker MINIATURE CIRCUIT BREAKER, 440VAC, 10A, CIRCUIT BREAKER TYPE: STANDARD

24973 Circuit Breaker MINIATURE CIRCUIT BREAKER, 440VAC, 10A, CIRCUIT BREAKER TYPE: STANDARD United States 24973 Circuit Breaker MINIATURE CIRCUIT BREAKER, 440VAC, 10A, CIRCUIT BREAKER TYPE: STANDARD Image not available Product Information Features and Specifications Approvals: IEC 60947-2 Rated

More information

C. New or replacement products installed in existing facilities shall be consistent with existing equipment.

C. New or replacement products installed in existing facilities shall be consistent with existing equipment. September 2012, rev 00 26 2923 Variable Frequency Controllers PART 1. GENERAL 1.01 Description A. This specification is to cover a complete Variable Frequency motor Drive (VFD) consisting of a pulse width

More information

Free Standing Emergency Department DGL Project No SECTION OVERCURRENT PROTECTIVE DEVICE COORDINATION STUDY PART 1 - GENERAL

Free Standing Emergency Department DGL Project No SECTION OVERCURRENT PROTECTIVE DEVICE COORDINATION STUDY PART 1 - GENERAL SECTION 26 05 73 1.1 SUMMARY OVERCURRENT PROTECTIVE DEVICE COORDINATION STUDY PART 1 - GENERAL A. This Section includes the following: 1. Requirements for computer-based, fault-current and overcurrent

More information

Eaton s Innovative Technology Surge Suppression Guideform Specification Low Exposure DIVISION 16 SECTION 16289

Eaton s Innovative Technology Surge Suppression Guideform Specification Low Exposure DIVISION 16 SECTION 16289 PART 1 - GENERAL DIVISION 16 SECTION 16289 TRANSIENT VOLTAGE SURGE SUPPRESSION (TVSS) 1.1 RELATED DOCUMENTS General: Drawings and general provisions of the Contract, including General and Supplementary

More information

UL 489 DIN rail branch circuit breakers

UL 489 DIN rail branch circuit breakers UL 9 DI rail branch circuit breakers FAZ-A circuit breakers Product Overview UL 9 DI rail branch circuit breakers FAZ-A circuit breakers PRODUCT OVERVIEW Optimum and efficient protection Optimum product

More information

Eaton s Innovative Technology Surge Suppression Guideform Specification High Exposure DIVISION 16 SECTION 16289

Eaton s Innovative Technology Surge Suppression Guideform Specification High Exposure DIVISION 16 SECTION 16289 PART 1 - GENERAL DIVISION 16 SECTION 16289 TRANSIENT VOLTAGE SURGE SUPPRESSION (TVSS) 1 RELATED DOCUMENTS General: Drawings and general provisions of the Contract, including General and Supplementary Conditions

More information

SECTION OVERCURRENT PROTECTIVE DEVICE COORDINATION STUDY

SECTION OVERCURRENT PROTECTIVE DEVICE COORDINATION STUDY SECTION 26 05 73 OVERCURRENT PROTECTIVE DEVICE PART 1 - GENERAL 1.1 SUMMARY A. Section includes computer-based, fault-current and overcurrent protective device coordination studies. Protective devices

More information

FTA750 LIMITED SERVICE FIRE PUMP CONTROLLERS STANDARD SUBMITTAL PACKAGE

FTA750 LIMITED SERVICE FIRE PUMP CONTROLLERS STANDARD SUBMITTAL PACKAGE FTA750 LIMITED SERVICE FIRE PUMP CONTROLLERS STANDARD SUBMITTAL PACKAGE SBP750-51(B) FTA750 Full Voltage Starting Limited Service Electric Fire Pump Controllers Product Description Description Firetrol

More information

1. Coordination of series-rated devices is permitted where indicated on Drawings.

1. Coordination of series-rated devices is permitted where indicated on Drawings. SECTION 16055 - OVERCURRENT PROTECTIVE DEVICE COORDINATION PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and

More information

60103 Circuit Breaker

60103 Circuit Breaker 6003 Circuit Breaker United States MINIATURE CIRCUIT BREAKER, 20/240VAC, 2A, CIRCUIT BREAKER TYPE: STANDARD Image not available Product Information Features and Specifications Circuit Breaker Type: Standard

More information

Circuit Protection Methods

Circuit Protection Methods Circuit Protection Methods Differentiating between Supplementary Protection, Branch Circuit Protection, and Self-Protected Devices Introduction Modern electrical equipment continues to increase in complexity

More information

The City of Winnipeg Dry Type Transformers up to 600 V Primary Section Bid Opportunity No Page 1 of 2

The City of Winnipeg Dry Type Transformers up to 600 V Primary Section Bid Opportunity No Page 1 of 2 The City of Winnipeg Dry Type Transformers up to 600 V Primary Section 26121601 Bid Opportunity No. 1196-2014 Page 1 of 2 Part 1 General 1.1 RELATED REQUIREMENTS.1 Section 26 05 01 - Common Work Results

More information

Selection Guide. Control Circuit and Load Protection. Allen-Bradley 1489-M2C020

Selection Guide. Control Circuit and Load Protection. Allen-Bradley 1489-M2C020 Selection Guide Control Circuit and Load Protection Circuit Protection Portfolio 1489-M Circuit Breakers Approved for branch circuit protection in the United States and Canada, and certified as Miniature

More information

1.1. Contactors and Starters... Contents Description Relays and Timers... Miniature Controls... Manual Motor Protectors. XT IEC Power Control

1.1. Contactors and Starters... Contents Description Relays and Timers... Miniature Controls... Manual Motor Protectors. XT IEC Power Control . Contents Description Relays and Timers......................... Miniature Controls......................... Contactors and Starters.................... Thermal Overload Relays.................... C440/XT

More information

SERIES RATED COMBINATIONS

SERIES RATED COMBINATIONS October 15, 2012 ELECTRICAL SECTION SERIES RATED COMBINATIONS The following information has been compiled from various equipment manufacture literature and the 22nd Edition of the BCEC for educational

More information

SECTION PANELBOARDS

SECTION PANELBOARDS SECTION 16450 PART 1 - GENERAL 1.01 DESCRIPTION A. Section includes requirements for panelboards providing fault interrupting capability and overcurrent protective devices. 1.02 REFERENCE STANDARDS A.

More information

I-Line Panelboards. Innovative design, smart bus technology, and simple installation

I-Line Panelboards. Innovative design, smart bus technology, and simple installation I-Line Panelboards Innovative design, smart bus technology, and simple installation TM Smart: designed for efficient installation Simple: Efficient Installation Process I-Line Breakers Main Lugs: Fixed-mounted

More information

Document C0. Use for:

Document C0. Use for: Date: July 27, 2015 Document C0 Use for: Connection of Electric Generation that will operate with an Open Transition (Category 1) between the Ameren System and the Generator or operate with a Synchronized

More information

MULTI 9 System Catalog UL Recognized NC100H Supplementary Protectors

MULTI 9 System Catalog UL Recognized NC100H Supplementary Protectors B Curve NC100H Supplementary Protectors Rating 1P 2P 3P 4P 80 MG27164 MG27175 MG27186 MG27197 MULTI 9 System Catalog UL Recognized NC100H Supplementary Protectors C Curve NC100H Supplementary Protectors

More information

Liebert AccuVar (ACV Series) Surge Protective Device (SPD) (With Noise Filtering) GUIDE SPECIFICATIONS for a Parallel Surge Suppression System

Liebert AccuVar (ACV Series) Surge Protective Device (SPD) (With Noise Filtering) GUIDE SPECIFICATIONS for a Parallel Surge Suppression System Liebert AccuVar (ACV Series) Surge Protective Device (SPD) (With Noise Filtering) GUIDE SPECIFICATIONS for a Parallel Surge Suppression System Part 1 General 1.01 Summary A. These specifications describe

More information

SECTION DISCONNECT SWITCHES

SECTION DISCONNECT SWITCHES SECTION 16440 DISCONNECT SWITCHES PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and other Division 01 Specification

More information

Electrical Service Change-Tn Neenah

Electrical Service Change-Tn Neenah Electrical Service Change-Tn Neenah Permit # Owners name Project address Contractors name Contractors address Fax #: Type of occupancy Job description New construction Main panel Single phase Additional

More information

MG24434 Supplementary Protector SUPPLEMENTARY PROTECTOR, 240VAC, 16A, CIRCUIT BREAKER TYPE: STANDARD

MG24434 Supplementary Protector SUPPLEMENTARY PROTECTOR, 240VAC, 16A, CIRCUIT BREAKER TYPE: STANDARD United States MG24434 Supplementary Protector SUPPLEMENTARY PROTECTOR, 240VAC, 16A, CIRCUIT BREAKER TYPE: STANDARD Product Information Features and Specifications For Use With: OEM Panels Approvals: UL

More information

Having communication issues? Model 6 intelligent Motor Control Centers communicate on all platforms. Make the most of your energy SM

Having communication issues? Model 6 intelligent Motor Control Centers communicate on all platforms. Make the most of your energy SM Having communication issues? Model 6 intelligent Motor Control Centers communicate on all platforms. Make the most of your energy SM Model 6 intelligent Motor Control Centers An intelligent solution. Intelligence.

More information

Jockey Pump Controllers

Jockey Pump Controllers BR081001EN Microprocessor Based with Color Touchscreen Product Description ACROSS THE LINE Controllers operate across-the-line. Full voltage is applied to the motor for starting by the use of a single

More information

TeSys IEC Contactors and Overload Relays

TeSys IEC Contactors and Overload Relays TeSys IEC Contactors and Overload Relays Making High-Fault Short-Circuit Current Ratings Simple Schneider Electric is an industry leader in IEC contactors and overload relays, and is recognized as the

More information

UL 489 or UL 1077 in control panels and equipment a quick guide

UL 489 or UL 1077 in control panels and equipment a quick guide UL 489 or UL 1077 in control panels and equipment a quick guide A common question that comes up with OEM machine builders and control panel builders is How do I know when to use UL 1077 or UL 489 breakers

More information

SECTION ELECTRIC METERING

SECTION ELECTRIC METERING SECTION 26 27 13 ELECTRIC METERING SPEC WRITER NOTES: Use this section only for NCA projects Delete between //----// if not applicable to project. Also delete any other item or paragraph not applicable

More information

JK Series POWER DISTRIBUTION. Solid State Starters Medium Voltage A

JK Series POWER DISTRIBUTION. Solid State Starters Medium Voltage A POWER DISTRIBUTION JK Series Solid State Starters Medium Voltage 200-400-600-720A SOLID STATE STARTER JKSSS4+ Series The JKSSS Series of motor starter is the result of extensive research and development.

More information

Spacing Requirements for Power Distribution and Terminal Blocks

Spacing Requirements for Power Distribution and Terminal Blocks Spacing Requirements for Power Distribution and Terminal Blocks New requirements in the 2005 NEC for a marked short-circuit current rating on industrial control panels, industrial machinery, and commercial/industrial

More information

Designing with Thermally Protected TCMOV Varistors for Type 1 and Type 2 UL1449 3rd Edition Applications

Designing with Thermally Protected TCMOV Varistors for Type 1 and Type 2 UL1449 3rd Edition Applications TCMOV Varistors for Type 1 and Type What is UL 1449? Underwriters Laboratories standard UL 1449 has become the primary safety standard for surge protective devices (SPDs). It describes the materials and

More information

MULTI 9 System Catalog

MULTI 9 System Catalog MULTI 9 System Catalog Class 80 CONTENTS Page Schneider Electric Brands Section Introduction... Section UL Rated Protection Devices... Section IEC 097- Rated Protection Devices... Section IEC Rated Ground-fault

More information

SECTION VARIABLE FREQUENCY MOTOR CONTROLLERS (VFD)

SECTION VARIABLE FREQUENCY MOTOR CONTROLLERS (VFD) SECTION 26 29 23 VARIABLE FREQUENCY MOTOR CONTROLLERS (VFD) PART 1 -GENERAL 1.1 SYSTEM DESCRIPTION A. Definitions: The Variable Speed AC Motor Drive (hereafter referred to as "VFD") shall be designed to

More information

MULTI 9 System Catalog UL Recognized C60N Supplementary Protectors

MULTI 9 System Catalog UL Recognized C60N Supplementary Protectors UL Recognized C60N Supplementary Protectors B Curve C60N Supplementary Protectors 1 MG24110 MG24125 MG24140 MG24155 15 MG17406 MG17436 MG17461 1.2 MG17402 MG17432 16 MG24118 MG24133 MG24148 MG24163 1.5

More information

Jockey Pump Controllers

Jockey Pump Controllers BR081001EN Microprocessor Based with Color Touchscreen Product Description ACROSS THE LINE Controllers operate across-the-line. Full voltage is applied to the motor for starting by the use of a single

More information

Page 1 of 149 First Revision No. 50-NFPA 79-2012 [ Global Input ] Delete the parenthetical terms used to describe IEC terms that follow terms used in NFPA 79 such as "protective bonding". Add information

More information

E1 Plus Electronic Overload Relay

E1 Plus Electronic Overload Relay ROCKWELL AUTOMATION PROCUREMENT SPECIFICATION PROCUREMENT SPECIFICATION E1 Plus NOTICE: The specification guidelines in this document are intended to aid in the specification of products. Specific installations

More information

Bulletin 1489 Circuit Breakers. Selection Guide

Bulletin 1489 Circuit Breakers. Selection Guide Bulletin 1489 s Selection Guide Overview/Description Bulletin 1489-A s Energy-limiting design protects downstream components better than conventional breakers during short circuits Field-mountable options

More information

STANDARD SUBMITTAL PACKAGE

STANDARD SUBMITTAL PACKAGE STANDARD SUBMITTAL PACKAGE SBP1000-51( ) FTA1000 Full Voltage Starting Electric Fire Pump Controllers Product Description Description Firetrol FTA1000 Full Voltage Fire Pump Controllers are intended for

More information

Variable Frequency Drive Design Guidelines

Variable Frequency Drive Design Guidelines Variable Frequency Drive Design Guidelines The Variable Frequency Drive Design Standard provides design criteria and specifications used in the procurement and application of variable frequency drives

More information

Explosion-Protected Arc-Fault Protection ExAFCI Arc-Fault Circuit Interrupter

Explosion-Protected Arc-Fault Protection ExAFCI Arc-Fault Circuit Interrupter Installation, Operation & Maintenance Sheet Explosion-Protected Arc-Fault Protection ExAFCI Arc-Fault Circuit Interrupter > Contents 1 Contents 1 Contents...2 2 General Information...2 2.1 Manufacturer...2

More information

For normal duty, design the VFD voltage level at 480 Volt, 3 Phase, 60 Hertz. (In Canada, 600 Volt, 3 Phase, 60 Hertz.)

For normal duty, design the VFD voltage level at 480 Volt, 3 Phase, 60 Hertz. (In Canada, 600 Volt, 3 Phase, 60 Hertz.) Introduction The Variable Frequency Drive Design Guidelines provides design criteria and specifications used in the procurement and application of variable frequency drives (VFDs). Table of Contents 1.

More information

SCCR Overall Panel Short Circuit Current Rating. per NEC and UL standards. Technical Paper Dipl-Ing. Wolfgang Esser.

SCCR Overall Panel Short Circuit Current Rating. per NEC and UL standards. Technical Paper Dipl-Ing. Wolfgang Esser. VER0211-959_D_GB 27.02.2007 13:15 Uhr Seite U4 www.moeller.net SCCR Overall Panel Short Circuit Current Rating Moeller addresses worldwide: www.moeller.net/address E-Mail: info@moeller.net per NEC and

More information

Stalking the Elusive and Somewhat Strange PV System

Stalking the Elusive and Somewhat Strange PV System A series of articles on photovoltaic (PV) power systems and the National Electrical Code by John Wiles PERSPECTIVES ON PV Stalking the Elusive and Somewhat Strange PV System Photo 1. Framed PV modules

More information

TRI-SERVICE ELECTRICAL WORKING GROUP (TSEWG) 07/16/08 TSEWG TP-3: SURGE PROTECTOR PERFORMANCE AND EVALUATION CRITERIA

TRI-SERVICE ELECTRICAL WORKING GROUP (TSEWG) 07/16/08 TSEWG TP-3: SURGE PROTECTOR PERFORMANCE AND EVALUATION CRITERIA TSEWG TP-3: SURGE PROTECTOR PERFORMANCE AND EVALUATION CRITERIA SURGE PROTECTION DESIGN. Parallel Versus Series Protection. Surge protectors within the scope of this UFC should normally be of the parallel

More information

Enhancing Reliability of Legacy Systems with New Generation Low-Voltage Circuit Breaker Upgrades

Enhancing Reliability of Legacy Systems with New Generation Low-Voltage Circuit Breaker Upgrades Enhancing Reliability of Legacy Systems with New Generation Low-Voltage Circuit Breaker Upgrades May 2012 / 1910DB1202 by Hal Theobald, Product Manager, Schneider Electric Services and Reza Tajali, P.E.,

More information

Electrical Plan Review

Electrical Plan Review Electrical Plan Review Overcurrent Protection and Devices, Short-Circuit Calculations, Component Protection, Selective Coordination, and Other Considerations Table of Contents Part I: Overcurrent Protection

More information

WMS SUPPLEMENTARY PROTECTORS

WMS SUPPLEMENTARY PROTECTORS WMS Supplementary Protectors Overview WMS SUPPLEMENTARY PROTECTORS Product Specification The WMS Supplementary Protector is a dual-rated product for both AC and DC supplies, in accordance with UL 1077

More information

SECTION SOLID-STATE REDUCED VOLTAGE STARTERS

SECTION SOLID-STATE REDUCED VOLTAGE STARTERS SECTION 26 29 13.16 PART 1 - GENERAL 1.1 THE REQUIREMENT A. General: The CONTRACTOR shall provide solid-state reduced voltage motor starters, complete and operable, in accordance with the Contract Documents.

More information

Miniature Circuit Breakers and Supplementary Protectors. Contents

Miniature Circuit Breakers and Supplementary Protectors. Contents . Optimum and Efficient Protection for Every Application Product Overview Features Optimum product quality, tested reliability and safety stand for best protection of personnel, installations and plant.

More information

Siemens AG I IA CE CP R&D-VI 4 WERNER-VON-SIEMENS-STRASSE AMBERG, GERMANY

Siemens AG I IA CE CP R&D-VI 4 WERNER-VON-SIEMENS-STRASSE AMBERG, GERMANY Issued to: Siemens AG I IA CE CP R&D-VI 4 WERNER-VON-SIEMENS-STRASSE 48 92220 AMBERG, GERMANY This is to certify that Auxiliary Devices representative samples of 3UF70 followed by 0 or 1 followed by 0

More information

Power System Protection Training

Power System Protection Training Power System Protection Training Contact us Today for a FREE quotation to deliver this course at your company?s location. https://www.electricityforum.com/onsite-training-rfq Refresh your knowledge of

More information

Great Western Painting Assured Equipment Grounding Conductor Program OR Ground Fault Circuit Interrupter (GFCI)

Great Western Painting Assured Equipment Grounding Conductor Program OR Ground Fault Circuit Interrupter (GFCI) Assured Equipment Grounding Conductor Program OR Ground Fault Circuit Interrupter (GFCI) GROUND FAULT CIRCUIT INTERRUPTERS Wiring design and protection. - 1926.404 Our company uses ground fault circuit

More information

WN U-60 Original Sheet No. 152

WN U-60 Original Sheet No. 152 WN U-60 Original Sheet No. 152 Table of Contents INTERCONNECTION WITH ELECTRIC GENERATORS 1) Introduction Sheet 152-A 2) Attachments Sheet 152-A 3) Definitions Sheet 152-B 4) Applicability Sheet 152-H

More information

Mitigating Arc Flash Hazards

Mitigating Arc Flash Hazards 1910DB1402 / March, 2015 by Antony Parsons, Ph.D., P.E. and Reza Tajali, P.E. Schneider Electric Engineering Services Make the most of your energy SM Contents 1.0 Introduction... 3 2.0 What is Arc Flash

More information

Gateway Module Programmable in C

Gateway Module Programmable in C User Manual for the HE660CGMx24 Gateway Module Programmable in C Second Edition 09 August 2000 MAN0025-02 MAN0025-02 09 AUG 2000 PAGE 3 PREFACE This manual explains how to use the Horner APG Gateway Module

More information

PanelFAST. Setting a new standard for immediate product availability with Square D Ready to Install (RTI) Panelboards

PanelFAST. Setting a new standard for immediate product availability with Square D Ready to Install (RTI) Panelboards PanelFAST Setting a new standard for immediate product availability with Square D Ready to Install (RTI) Panelboards Whether you planned ahead or have an unexpected project, why wait? You should expect

More information

SURGE PROTECTION USER MANUAL. Surge Protection Device PORTABLE POWER DISTRIBUTION SURGE PROTECTION DEVICE (SPD) B

SURGE PROTECTION USER MANUAL. Surge Protection Device PORTABLE POWER DISTRIBUTION SURGE PROTECTION DEVICE (SPD) B SURGE PROTECTION PORTABLE POWER DISTRIBUTION SURGE PROTECTION DEVICE (SPD) USER MANUAL Surge Protection Device B 01 156 9000 This Surge Protection Device is intended for professional use only Read this

More information

White Paper October 2009

White Paper October 2009 ANSI /UL1449 Third Edition Safety Standard (New UL and NEC standards means new performance levels, test procedures and markings to products and manufacturers) White Paper October 2009 The past two years

More information

FORM FOR PROPOSAL FOR 2014 NATIONAL ELECTRICAL CODE

FORM FOR PROPOSAL FOR 2014 NATIONAL ELECTRICAL CODE FORM FOR PROPOSAL FOR 2014 NATIONAL ELECTRICAL CODE INSTRUCTIONS PLEASE READ CAREFULLY Type or print legibly in black ink. Use a separate copy for each proposal. Limit each proposal to a SINGLE section.

More information

BSPD Surge Protective Devices

BSPD Surge Protective Devices BUSSMANN Supersedes December 2016 SERIES BSPD Surge Protective Devices High capacity Type 1 and Type 2 SPDs for overvoltage protection on Contents Description Page Introduction 2 Applications 2 Features

More information

Title Power Supply Units for Signalling Equipment - DC (Regulated & Filtered) Units. Reference Number SPS 30 - (RIC Standard: SC SP)

Title Power Supply Units for Signalling Equipment - DC (Regulated & Filtered) Units. Reference Number SPS 30 - (RIC Standard: SC SP) Discipline Engineering Standard - NSW Category Signalling Title Power Supply Units for Signalling Equipment - DC (Regulated & Filtered) Units Reference Number SPS 30 - (RIC Standard: SC 09 10 07 00 SP)

More information

SECTION 16450: NON-AUTOMATIC TRANSFER SWITCH / QUICK CONNECT GENERATOR SWITCHBOARD <S> <OM>

SECTION 16450: NON-AUTOMATIC TRANSFER SWITCH / QUICK CONNECT GENERATOR SWITCHBOARD <S> <OM> SECTION 16450: NON-AUTOMATIC TRANSFER SWITCH / QUICK CONNECT GENERATOR SWITCHBOARD PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General

More information

Allen-Bradley Bulletin 100 Contactors

Allen-Bradley Bulletin 100 Contactors Allen-Bradley Bulletin 100 Contactors An integrated portfolio of IEC Contactors that save panel-space and energy Features and Benefits: Direct-on-line and reversing contactors Built-in surge suppression

More information

Switchgear Design Impacts the Reliability of Backup Power Systems

Switchgear Design Impacts the Reliability of Backup Power Systems Switchgear Design Impacts the Reliability of Backup Power Systems December 2010/AT307 by Reza Tajali, P.E. Square D Power Systems Engineering Make the most of your energy SM Revision #1 12/10 When a cascaded

More information

SECTION SURGE PROTECTIVE DEVICES

SECTION SURGE PROTECTIVE DEVICES SECTION 16289 PART 1 GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification Sections, apply to this

More information

User s Guide. POWERVAR Single Phase Power Conditioners

User s Guide. POWERVAR Single Phase Power Conditioners POWERVAR Single Phase Power Conditioners User s Guide Industrial Conditioners GPI Series B Conditioners GPI Series 1 Conditioners 2-15 kva Single Phase Conditioners GPI Series 1 Conditioners RoHS Compliant

More information

Installation Instructions for Eaton Surge Protective Device XXCFXXX10-DIN and XXCFXXX10-DIN2

Installation Instructions for Eaton Surge Protective Device XXCFXXX10-DIN and XXCFXXX10-DIN2 Supersedes 6/2015 Surge Protective Device XXCFXXX10-DIN and XXCFXXX10-DIN2 XXCFXXX10-DIN Contents Description Page 1.0 Setup...2 1.1 Before Installation...2 1.2 Installation...3 For AC Applications...3

More information

Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protectors Specifications Bulletin Number 1492, 1692

Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protectors Specifications Bulletin Number 1492, 1692 Technical Data Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protectors Specifications Bulletin Number 1492, 1692 Topic Page 1489-M Miniature Circuit Breakers 1 1492-SP Supplementary Protectors

More information

Installation, Testing, and Operating Procedures 30 AMP PORTABLE AND PERMANENT SERIES GFCI SINGLE and MULTIPHASE

Installation, Testing, and Operating Procedures 30 AMP PORTABLE AND PERMANENT SERIES GFCI SINGLE and MULTIPHASE IMPORTANT! Please read all the information on this sheet. SAVE THESE INSTRUCTIONS! NOTICE BEFORE USING READ INSTRUCTIONS COMPLETELY. TO BE INSTALLED BY A QUALIFIED ELECTRICIAN IN ACCORDANCE WITH NATIONAL

More information

Line reactors SINAMICS. SINAMICS G120P Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation 4

Line reactors SINAMICS. SINAMICS G120P Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation 4 Safety information 1 General 2 SINAMICS SINAMICS G120P Mechanical installation 3 Electrical installation 4 Technical specifications 5 Operating Instructions Control version V4.6 11/2013 A5E32845290B AA

More information

Ground Fault Current Protection Devices Prevent Costly Production Shutdowns

Ground Fault Current Protection Devices Prevent Costly Production Shutdowns Ground Fault Current Protection Devices Prevent Costly Production Shutdowns Figure.1 Altech s three new series deliver multiple capabilities. In all three series, ground fault sensitivity levels range

More information

The Leviton Load Center THE FUTURE MADE CURRENT

The Leviton Load Center THE FUTURE MADE CURRENT The Leviton Load Center THE FUTURE MADE CURRENT Raising the Bar Again For over 110 years, Leviton has cultivated a rich tradition of safety and innovation, developing electrical products that set the

More information

Supplement to Instruction Manual

Supplement to Instruction Manual Supplement to Instruction Manual Compact Inverter 0 V series: FRN0001 to 00C2S-2U 400 V series: FRN0002 to 0011C2S-4U Single-phase 0 V series: FRN0001 to 0012C2S-7U Thank you for purchasing our FRENIC-Mini

More information

SENTRON. Protective devices Selectivity for 3VA molded case circuit breakers. Introduction. Selectivity - terms and definitions

SENTRON. Protective devices Selectivity for 3VA molded case circuit breakers. Introduction. Selectivity - terms and definitions Introduction 1 Selectivity - terms and definitions 2 SENTRON Methods of implementing selectivity using circuit breakers 3 Protective devices Selectivity for 3VA molded case circuit breakers Configuration

More information

Bulletin 1492-MC 1492-MCGA, -MCEA 1492-SP

Bulletin 1492-MC 1492-MCGA, -MCEA 1492-SP Bulletin Control Circuit and Load Protection Product Overview Bulletin -MC -MCGA, -MCEA -SP Type Branch Ground Fault Detection Features /V, V & Y/V rating A interrupt / in. per pole wide... A @ UL Circuit

More information

2008 Code Changes for Power Distribution

2008 Code Changes for Power Distribution 2008 Schaedler Yesco Expo 2008 Code Changes for Power Distribution April 17, 2008 / Version 1.0 For internal use only / Copyright Siemens AG 2007. 2008. All rights reserved. Contact Consulting Account

More information

PLT. Breaker-based transfer switch open, closed or soft transition amps. Specification sheet

PLT. Breaker-based transfer switch open, closed or soft transition amps. Specification sheet Specification sheet PLT Breaker-based transfer switch open, closed or soft transition 800 3000 amps Description PLT breaker-based transfer switches are designed for operation and switching of electrical

More information

SECTION ( ) LIGHTING CONTROL PANELBOARD

SECTION ( ) LIGHTING CONTROL PANELBOARD (26 24 16.02) LIGHTING CONTROL PANELBOARD PART 1 GENERAL 1.01 SCOPE A. The Contractor shall furnish and install Lighting Control Panelboards as specified and as shown on the contract drawings. B. The Lighting

More information

UL ISBN Low-Voltage Fuses Part 10: Class L Fuses

UL ISBN Low-Voltage Fuses Part 10: Class L Fuses UL 248-10 ISBN 0-7629-0560-3 Low-Voltage Fuses Part 10: Class L Fuses AUGUST 1, 2000 UL 248-10 tr1 Underwriters Laboratories Inc. (UL) 333 Pfingsten Road Northbrook, IL 60062-2096 UL Standard for Safety

More information

Spring Test 9 due 05/11/2013

Spring Test 9 due 05/11/2013 Spring Test 9 due 05/11/2013 Multiple Choice Identify the choice that best completes the statement or answers the question. 1. A grounding electrode is. a. a solid conductor b. a circuit conductor that

More information

FAZ Supplementary Protectors, FAZ Miniature Circuit Breakers, P2 Disconnect Switches Overview

FAZ Supplementary Protectors, FAZ Miniature Circuit Breakers, P2 Disconnect Switches Overview FAZ Supplementary Protectors, FAZ Miniature Circuit Breakers, P2 Disconnect Switches Overview Supplementary Protectors / Miniature Circuit Breakers Page System overview 10/003 10/001 Supplementary protectors

More information

Broadband Automatic Disconnect Switch. User Manual

Broadband Automatic Disconnect Switch. User Manual Reset/Test Primary/ Primary Broadband Automatic Disconnect Switch User Manual Local Power Remote Pwer Local 63V Fault Secondary Select Secondary 220V Normal 990-1929 09/2004 Introduction Introduction

More information