Main contacts Auxiliary contact Number of input channels Rated voltage Model Category 24 VAC/VDC 3PST-NO SPST-NC 1 channel or 2 channels possible

Size: px
Start display at page:

Download "Main contacts Auxiliary contact Number of input channels Rated voltage Model Category 24 VAC/VDC 3PST-NO SPST-NC 1 channel or 2 channels possible"

Transcription

1 Safety Relay Unit Four kinds of -mm wide Units are available: A -safety contact model, a -safety contact model, and models with safety contacts and OFF-delay safety contacts. Also available are 7.-mm wide Expansion Units with safety contacts and OFF-delay safety contacts. Two hand controller (type III C, EN 7) Simple expansion connection. OFF-delay models have -step OFFdelay settings. Conforms to EN standards. (BG approval) Approved by UL and CSA. Both DIN track mounting and screw mounting are possible. Suitable for PNP OSSD outputs of safety sensors, FSN, FSH, FS-B, FS-TGR, FSL The Series Offers a Complete Line-up of Compact Units. Ordering Information Emergency-stop Units Main contacts Auxiliary contact Number of input channels Rated voltage Model Category VAC/VDC PST-NO SPST-NC channel or channels possible to 0 VAC VAC/VDC PST-NO SPST-NC channel or channels possible to 0 VAC Emergency-stop OFF-delay Units Main contacts OFF-delay contacts Auxiliary contact PST-NO DPST-NO SPST-NC Number of input channels channel or channels possible Note: The following -step OFF-delay time settings are available: T07: 0.,,.,,.,,.,,.,,.,,., 7, and 7. s T:,,,,,, 7, 8, 9, 0,,,,, and s T0:,,, 8, 0,,,, 8, 0,,,, 8, and 0 s Two-hand ler OFF-delay time 7. s s 0 s Rated voltage Model Category VAC/VDC 00 to 0 VAC VAC/VDC 00 to 0 VAC VAC/VDC 00 to 0 VAC --T07 --T --T0 Main contacts: OFF-delay contacts: Main contacts Auxiliary contact Number of input channels Rated voltage Model Category PST-NO SPST-NC channels VAC/VDC 00 to 0 VAC -TH0 (IIIc, EN7) Expansion Unit The Expansion Unit connects to a -0, -0, -, or -TH0. Main contacts Auxiliary contact Model Category PST-NO SPST-NC -EX0 G-09

2 Expansion Units with OFF-delay Outputs The Expansion Unit connects to a -0, -0, -, or -TH0. Main contact form Auxiliary contact OFF-delay time Model Category PST-NO SPST-NC Note: The following -step OFF-delay time settings are available: T07: 0.,,.,,.,,.,,.,,.,,., 7, and 7. s T:,,,,,, 7, 8, 9, 0,,,,, and s T0:,,, 8, 0,,,, 8, 0,,,, 8, and 0 s 7. s -EX0-T07 s -EX0-T 0 s -EX0-T0 Model Number Legend -######-####. Function None: Emergency stop EX: Expansion Unit TH: Two-hand ler. Contact Configuration (Safety Output) 0: None : PST-NO : PST-NO. Contact Configuration (OFF-delay Output) 0: None : DPST-NO : PST-NO. Contact Configuration (Auxiliary Output) 0: None : SPST-NC. Input Configuration (for -0/0/) None: -channel or -channel input possible. OFF-delay Time (Max. setting time) None: No OFF-delay T07: 7. seconds T: seconds T0: 0 seconds G-0 Safety Sensors / Components

3 Specifications Ratings Power Input Power supply voltage Note: When an Expansion Unit is connected, the power consumption is increased by VA/ W max. Inputs Note: When an Expansion Unit is connected, the input current is increased by 0 ma max. Contacts Item -0/TH0-0 --T# Operating voltage range Power consumption (See note.) VAC/VDC: VAC, 0/0 Hz, or VDC 00 to 0 VAC:00 to 0 VAC, 0/0 Hz 8% to 0% of rated power supply voltage VAC/VDC:.8 VA/.7 W max. 00 to 0 VAC: 9 VA max. VAC/VDC:.8 VA/. W max. 00 to 0 VAC: VA max. Item -0/-T#/TH0-0 Input current (See note.) 0 ma max. 0 ma max. VAC/VDC:. VA/. W max. 00 to 0 VAC:. VA max. Rated load Item Rated carry current -0/0/-T#/TH0/EX0/EX0-T# Resistive load (cos φ =) 0 VAC, A A Characteristics Item -0/TH0-0/-T# -EX0/EX0-T# Contact resistance (see note ) Operating time Response time (see note ) 00 mω 0 ms max. (not including bounce time) 0 ms max. (not including bounce time) Insulation resistance (see note ) 00 MΩ min. (at 00 VDC) Between different outputs Between inputs and outputs Dielectric Between power inputs and outputs strength,00 VAC, 0/0 Hz for min Between power inputs and other inputs (only for 00 to 0-V models) Vibration resistance 0 to Hz, 0.7-mm double amplitude Shock Destruction 00 m/s resistance Malfunction 00 m/s Durability Mechanical,000,000 operations min. (at approx. 7,00 operations/hr) Electrical 00,000 operations min. (at approx.,800 operations/hr) Minimum permissible load (reference value) VDC, ma Ambient temperature Operating:- C to C (with no icing or condensation) Storage:- C to 8 C (with no icing or condensation) Ambient humidity Operating:% to 8% Storage:% to 8% Terminal tightening torque 0.98 N m Weight (see note ) Approx. 0 g Approx. 70 g Approx. 0 g Approved standards EN9-, EN00-, EN7 (-TH0), UL08, CSA C. No. EMC EMI: EN0 group class A EMS: EN008- group Note:. The contact resistance was measured with A at VDC using the voltage-drop method.. The response time is the time it takes for the main contact to open after the input is turned OFF.. The insulation resistance was measured with 00 VDC at the same places that the dielectric strength was checked.. Weight shown is for -VAC/VDC type. For 00 to 0-VAC type, add approximately 0 g. G-

4 Application Examples -0 ( VAC/VDC) with -channel Limit Switch Input/Auto-reset Limit switches S and S S: Safety Limit Switch with direct opening mechanism (DN or DB) S: Limit switch : Magnetic Contactor M: -phase motor Note: This achieves EN9- Safety Category. -0 ( VAC/VDC) with -channel Limit Switch Input/Manual-reset Limit switches S and S Reset switch S PC input PC output KM S: Safety Limit Switch with direct opening mechanism (DN or DB) S: Limit switch S: Reset switch : Magnetic Contactor KM: Solid-state Contactor M: -phase motor Note: This achieves EN9- Safety Category. G- Safety Sensors / Components

5 -0 (00 to 0 VAC) with -channel Limit Switch Input/Auto-reset Limit switches S and S S: Safety Limit Switch with direct opening mechanism (DN or DB) S: Limit switch : Magnetic Contactor M: -phase motor Note: This achieves EN9- Safety Category. -0 ( VAC/VDC) with -channel Emergency Stop Switch Input/Manual-reset Emergency stop switch S Reset switch S PC input PC output KM S: Emergency stop switch with direct opening mechanism (AE or AE) S: Reset switch : Magnetic Contactor KM: Solid-state Contactor M: -phase motor Note: This achieves EN9- Safety Category. G-

6 --T# ( VAC/VDC) with -channel Limit Switch Input/Manual-reset Off delay timer S: Safety Limit Switch with direct opening mechanism (DN or DB) S: Limit switch S: Reset switch : Magnetic Contactor M: -phase motor Operation instruction Motor controller Limit switches S and S Reset switch S K and K K and K Operation instruction Motor rotation OFF-delay time Note: This achieves EN9- Safety Category. The OFF-delay output, however, achieves EN9- Safety Category. G- Safety Sensors / Components

7 --T# ( VAC/VDC) + -EX0-T# with -channel Limit Switch Input/Manual-reset Off delay timer Off delay timer S: Safety Limit Switch with direct opening mechanism (DN or DB) S: Limit switch S: Reset switch KM, KM, KM, and KM: Magnetic Contactor M, M: -phase motor Limit switches S and S Reset switch S --T# --T# --T# K and K --T# K and K Operation instruction Motor M rotation -EX0 -EX-0 KM and KM KM and KM Operation instruction Motor M rotation OFF-delay time OFF-delay time Operation instruction Motor controller Operation instruction Note: This achieves EN9- Safety Category. The OFF-delay output, however, achieves EN9- Safety Category. Motor controller G-

8 -0 ( VAC/VDC) with -channel Safety Area Sensor/Manual-reset Emitter Receiver FSN-A Incident Interrupted Reset switch S FSN-A FSH-A PC input PC output RS-8(A) (Gray) KM Shield 0V (Blue) (Red) Test input (Green) Reset input (Yellow) Interlock selection input (White) +V (Brown) RS-8(B) (Pink) +V (Brown) EDM input (Red) Auxiliary (Yellow) OSSD (Green) OSSD (White) 0V (Blue) Shield FSN-A: Safety area sensor S: Reset switch : Magnetic Contactor KM: Solid-state Contactor M: -phase motor E: -VDC Power Supply Note: This achieves EN9- Safety Category. KM E G- Safety Sensors / Components

9 -TH0 ( VDC) with -hand Inputs/Auto-reset (See note.) S S S S 0. s max. Input time difference operates only when the difference is 0. s max. S, S: Two-hand pushbutton switches : Magnetic Contactor Note:. Use a NC+NO switch for S and S.. This achieves EN9- Safety Category. Typ III C (EN 7) G-7

10 -0 ( VAC/VDC) and -EX0 with -channel Limit Switch Input/Manual-reset S: Safety Limit Switch with direct opening mechanism (DN or DB) S: Limit switch S: Reset switch : Magnetic Contactor M: -phase motor Limit switches S and S Reset switch S -0,, K and K -0,, K, and K -EX0 -EX0 Note: This achieves EN9- Safety Category. G-8 Safety Sensors / Components

11 Dimensions Note: All units are in millimeters unless otherwise indicated. The diagrams are drawn in perspective T# -TH0-0 Terminal Arrangement -0 --T# -TH0 OFFdelay time setting switch (see note) C D. dia. -0: Twenty, M -0: Twenty-four, M --T#: Twenty-four, M -TH0: Twenty-one, M Mounting Holes Two,. dia. or M 7 max. OFF-delay time setting switch (see note) Connector cover Note: The OFF-delay time setting switch is found on the --T# only. max. max. -EX0 -EX0-T# Mounting Holes Two,. dia. or M Terminal Arrangement -EX0 -EX0-T# Eight, M OFF-delay time setting switch (see note). dia. 7 max. OFF-delay time setting switch (see note) Note: The OFF-delay time setting switch is found on the -EX0-T# only. 7. max. max. G-9

12 Installation Internal Connections -0 ( VAC/VDC) A A T T T T a b a b JP -0 (00 to 0 VAC) PE T T T AB (See note.) (See note.) (See note.)(see note.) -0 ( VAC/VDC) -0 (00 to 0 VAC) A A T T T T a K K b a b K K JP A A T PE T T T T (See note.) (See note.) --T# ( VAC/VDC) A B T T (See note.)(see note.) --T# (00 to 0 VAC) a b K K Off delay timer a b K K JP Off delay timer PE T T T A B (See note.) (See note.) (See note.) (See note.) -TH0 ( VAC/VDC) -TH0 (00 to 0 VAC) A A T T T T T JP PE T T T C D -EX0 -EX0-T# Off delay timer (See note.) (See note.) Note:. Use terminals A and B to switch reset mode. A to B open: Manual reset A to B closed: Auto-reset. Use terminals C and D to switch input conditions. C to D open: DPDT input. C to D closed: DPST-NC input. (Make sure T and T are open.). Use terminal T with + common -channel input. When using T, make sure that T and T are open. For -channel input, make sure T and T are closed.. With 00 to 0-VAC type, be sure to connect PE to a protective ground. With -VAC/VDC type, if the power supply is not connected to a protective ground, be sure to connect PE to a protective ground.. With -VAC/VDC type, the power supply terminals A and A have polarities. A is the negative pole. G-0 Safety Sensors / Components

13 Precautions Do not touch the terminal area of the Relays or the socket terminal area (charged area) while power is ON. Electric shock will result. Wiring Turn OFF the before wiring the. Do not touch the terminals of the while the power is turned ON, because the terminals are charged and may cause an electric shock. Use the following to wire the. Stranded wire: 0.7 to. mm Solid wire:.0 to. mm Tighten each screw to a torque of 0.78 to.8 N m, or the may malfunction or generate heat. External inputs connected to T and T or T and T of the -0 must be no-voltage contact inputs. PE is a ground terminal. When a machine is grounded at the positive, the PE terminal should not be grounded. Mounting Expansion Units Turn OFF the before connecting the Expansion Unit. When an Expansion Unit is being used, remove the connector cover from the Safety Relay Unit (-0, -0, - #, or -TH0) and insert the connector of the Expansion Unit s connector cable. Applicable Safety Category (EN9-) -series Relays meet the requirements of Safety Category of the EN9- standards when they are used as shown in the examples provided by OMRON. The Relays may not meet the standards in some operating conditions. The OFF-delay output of models --T# and EX0-T#, however, conform to Safety Category. The applicable safety category is determined from the whole safety control system. Make sure that the whole safety control system meets EN9- requirements. Mounting Multiple Units When mounting multiple Units close to each other, the rated current will be A. Do not apply a current higher than A. Connecting Inputs If using multiple models, inputs cannot be made using the same switch. This is also true for other input terminals. Earth Short A positive thermistor is built into the s, so you can detect earth short breakdowns and breakdown shorts between channel and channel. If the short breakdown is canceled, reset is automatic. G-

14 ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by To convert grams into ounces, multiply by Cat. No. J-E-0A-X In the interest of product improvement, specifications are subject to change without notice. G- Safety Sensors / Components

G9SA. Ordering Information. Safety Relay Unit. The G9SA Series Offers a Complete Line of Compact Units. H Several types of 45-mm wide Units are

G9SA. Ordering Information. Safety Relay Unit. The G9SA Series Offers a Complete Line of Compact Units. H Several types of 45-mm wide Units are Safety Relay Unit The G9SA Series Offers a Complete Line of Compact Units H Several types of -mm wide Units are available: a -pole model, a -pole model, models with poles and OFF-delay poles H 7.-mm wide

More information

DPST-NO None 2 channels Auto-reset Inverse (+/-) 24 VAC/VDC 4 G9SB-2002-A 1 channel or 2

DPST-NO None 2 channels Auto-reset Inverse (+/-) 24 VAC/VDC 4 G9SB-2002-A 1 channel or 2 Safety Relay Unit Ultra Slim Safety Relay Unit 17.5 mm wide models available with 2 or 3 poles. 22.5 mm wide 3 pole models also available EN Standards (TÜV approval) DIN-track mounting possible Ordering

More information

G9SA. Safety Relay Unit. The G9SA Series Offers a Complete Line-up of Compact Units. Model Number Structure

G9SA. Safety Relay Unit. The G9SA Series Offers a Complete Line-up of Compact Units. Model Number Structure Safety Relay Unit G9 CSM_G9_DS_E The G9 Series Offers a Complete Line-up of Compact Units. Four kinds of -mm wide Units are available: A -pole model, a -pole model, and models with poles and OFF-delay

More information

Safety Monitoring Relays

Safety Monitoring Relays Safety Monitoring Relays G9SA G9SA Safety Relay Unit Four kinds of 45-mm wide units are available: A 3-pole model, a 5-pole model, and models with 3 poles and 2 OFF-delay poles, as well as a two-hand controller.

More information

Tecnología en Electrónica y Control SRL Ficha Técnica

Tecnología en Electrónica y Control SRL Ficha Técnica Tecnología en Electrónica y Control SRL Ficha Técnica Relé de seguridad Tecnología en Electrónica y Control SRL Oficina Central Wüthrich 949 San Carlos Centro (S3013DES) / Santa Fe / Argentina Tel./Fax/Líneas

More information

Safety Relay Unit (I/O Unit Type)

Safety Relay Unit (I/O Unit Type) Safety Relay Unit (I/O Unit Type) CQM1-SF200/ CS1W-SF200 Same Dimensions as I/O Unit Less Installation Space and Wiring Required Safety Relay Unit that can be used as an I/O Unit for OMRON s CQM1H and

More information

Safety Monitoring Relays

Safety Monitoring Relays Safety Monitoring Relays Contents Selection Guide I-2 Safety Monitoring Relays G9SA I-6 SR101A I-12 SR103AM I-13 SR104P I-17 SR105E I-17 SR106ED I-21 SR108AD & SR109AD I-18 SR120MP I-21 SR125SMS45 I-22

More information

Number of input channels

Number of input channels Safety Relay Unit (Sensor Connector Type) CSM DS_E_3_1 Less Wiring Required with Safety Light Curtain Sensor connector allows direct connection to OMRON 3SJ Safety Light Curtains with PNP outputs. Reduces

More information

Model Number Structure

Model Number Structure Solid State Relays with Failure Detection Function G3PC CSM_G3PC_DS_E_1_1 Refer to Safety Precautions for All Solid State Relays. Detects failures in SSR used for heater temperature control and simultaneously

More information

Solid-state Timer. Ordering Information. Specifications. Miniature Timer Compatible with the MY Relay. Accessories. Time Ranges

Solid-state Timer. Ordering Information. Specifications. Miniature Timer Compatible with the MY Relay. Accessories. Time Ranges Solid-state Timer Miniature Timer Compatible with the MY Relay Large transparent time-setting knob facilitates time setting. Flat-blade and Phillips screwdrivers can also be used for time setting. Approved

More information

SPST-NO SPDT DPST-NO DPDT

SPST-NO SPDT DPST-NO DPDT Next-generation PCB Relay Available in Various Models ROHS compliant. High sensitivity: (250mW) and high capacity (16A) models available Low profile: 15.7 mm max. in height. Conforms to EN 61810-1, UL508

More information

Model Number Structure

Model Number Structure Solid State Relays with Failure Detection Function G3PC Detects failures in SSR used for heater temperature control and simultaneously outputs alarm signal. This SSR supports the safe design of heater

More information

G3PC. Model Number Structure. Solid State Relays with Failure Detection Function. Model Number Legend

G3PC. Model Number Structure. Solid State Relays with Failure Detection Function. Model Number Legend Solid State Relays with Failure Detection Function G3PC Refer to Warranty and Application Considerations (page 1), Safety Precautions (page 4), and Technical and Safety Information (page 6). Detects failures

More information

D2D. Door Interlock Switch. Ordering Information. Power Switch with Minimum Contact Gap of 3 mm. Model Number Legend.

D2D. Door Interlock Switch. Ordering Information. Power Switch with Minimum Contact Gap of 3 mm. Model Number Legend. Door Interlock Switch Power Switch with Minimum Contact Gap of 3 mm Offers the minimum contact gap of 3 mm required for power switches as standard equipment. Highly reliable design conforms to European

More information

Solid-state Timer. Ordering Information. Miniature Timer with Multiple Time Ranges and Multiple Operating Modes H3YN- - Accessories (Order Separately)

Solid-state Timer. Ordering Information. Miniature Timer with Multiple Time Ranges and Multiple Operating Modes H3YN- - Accessories (Order Separately) Solid-state Timer Miniature Timer with Multiple Time Ranges and Multiple Operating Modes Minimizes stock. Pin configuration compatible with MY Power Relay. Standard multiple operating modes and multiple

More information

Solid-state Timer. Ordering Information. Ultra-slim Timer for G2R Relay Socket. H3RN-jj. Accessories (Order Separately) Connecting Socket

Solid-state Timer. Ordering Information. Ultra-slim Timer for G2R Relay Socket. H3RN-jj. Accessories (Order Separately) Connecting Socket Solid-state Timer Ultra-slim Timer for G2R Relay Socket Pin configuration compatible with G2R Relay and mounts to the P2R/P2RF Socket. Standard multiple time ranges and multiple operating modes. Conforms

More information

Solid-state Timer H3YN

Solid-state Timer H3YN Solid-state Timer H3YN Miniature Timer with Multiple Time Ranges and Multiple Operating Modes Minimizes stock. Pin configuration compatible with MY Power Relay. Standard multiple operating modes and multiple

More information

Model Number Structure

Model Number Structure Solid State Relays CSM DS_E_3_1 Compact, Low-cost, SSR Switching 5 to 20 A Wide load voltage range: 75 to 264 VAC. Both 100-V and 200-V loads can be handled with the same model. Dedicated, compact aluminum

More information

Slim Relay G2RV. Model Number Structure. Ordering Information. Model Number Legend. List of Models. Relay and Socket Combinations

Slim Relay G2RV. Model Number Structure. Ordering Information. Model Number Legend. List of Models. Relay and Socket Combinations Slim Relay G2RV The World's First Industrial Slim Relay Large plug-in terminals for reliable connection. LED indicator and mechanical flag to check operation. Transparent housing enables checking relay

More information

G9SX-GS. Safety Guard Switching Unit. A Safety Measure for Hazardous Operations That Does Not Lower Productivity. Auto Switching Function

G9SX-GS. Safety Guard Switching Unit. A Safety Measure for Hazardous Operations That Does Not Lower Productivity. Auto Switching Function Safety Guard Switching Unit CSM DS_E_6_1 A Safety Measure for Hazardous Operations That Does Not Lower Productivity Two functions support two types of application: Auto switching: For applications where

More information

Setting method Indication Control Output Model method mode Thermocouple (with sensor burnout detection circuit)

Setting method Indication Control Output Model method mode Thermocouple (with sensor burnout detection circuit) Temperature Controller DIN-sized (48 x 48 mm) Temperature Controller With Digital Setting Compact, low-cost Temperature Controller Incorporates proportional adjustment and reset adjustment function. Incorporates

More information

Thread length (overall length) material

Thread length (overall length) material Cylindrical Proximity Sensor for Mobile Usage Designed and tested to keep your machines moving IP69k tested and certified for highest water resistance e1 type approval (according to automotive directive

More information

Making Hazardous Operations Safe and Productive

Making Hazardous Operations Safe and Productive NEW Safety Guard Switching Unit G9SX-GS Making Hazardous Operations Safe and Productive Making Hazardous Operations Safe and Productive This new addition to the model of Flexible Safety Unit G9SX series

More information

(Applicable output load) to 264 (see note 2) (see note 1) (2Aat75to264VAC) G3R-202SLN-US PCB Yes 2 A at 100 to 120 VDC. (2 A at 75 to 132 VDC)

(Applicable output load) to 264 (see note 2) (see note 1) (2Aat75to264VAC) G3R-202SLN-US PCB Yes 2 A at 100 to 120 VDC. (2 A at 75 to 132 VDC) Solid-state Relay Compact SSRs Ideal for Built-in Applications Vertical, compact SSRs with an operation indicator offered in versatile variations. Can be mounted side by side with an electromagnetic relay

More information

Inductive Proximity Sensor

Inductive Proximity Sensor Inductive Proximity Sensor Miniature, Slim-styled Proximity Sensor Space-saving Sensor ideal for timing cam and dog detection. Four mounting holes provided: two each mounting from side or rear of the housing.

More information

must Operate Voltage (V)

must Operate Voltage (V) force-guided relays g7sa G7SA compact, Slim relays conforming to en Standards Relays with forcibly guided contacts (EN50205 Class A, certifi ed by VDE) Supports the CE marking of machinery (Machinery Directive)

More information

Classification Enclosure rating Input voltage Type of

Classification Enclosure rating Input voltage Type of Slim Relay G2RV The World's First Industrial Slim Relay Large plug-in terminals for reliable connection. LED indicator and mechanical flag to check operation. Special input type with gold plated contacts.

More information

Expansion Unit G9SX-EX Safety 2 Instantaneous safety outputs

Expansion Unit G9SX-EX Safety 2 Instantaneous safety outputs Flexible Safety Unit / Safety Guard Switching Unit G9SX/G9SX-GS CSM_G9SX_G9SX-GS_DS_E_8_1 Logical Function Adds Flexibility to Various Safety Circuits Be sure to read the Safety Precautions on page 45.

More information

Model Number Structure

Model Number Structure Analogue Temperature Controller E5C2 DIN-sized (48 x 48 mm) Temperature Controller with Analog Setting Compact, low-cost Temperature Controller. Incorporates proportional control and reset adjustment function.

More information

Model Number Structure

Model Number Structure Thumbwheel Switch Refer to Warranty and Application Considerations (page 1) and Safety Precautions (page 3). General-purpose Thumbwheel Switches A wide range of output codes are available. Use the back-mounting

More information

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment FAST SHIPPING AND DELIVERY TENS OF THOUSANDS OF IN-STOCK ITEMS EQUIPMENT DEMOS HUNDREDS OF MANUFACTURERS SUPPORTED

More information

Special-purpose Basic Switch

Special-purpose Basic Switch Special-purpose Basic Switch DPDT Basic Switch for Two Independent Circuit Control Incorporates two completely independent built-in switches. Ideal for switching the circuits operating on two different

More information

D2D. Door Interlock Switch. Ordering Information. Power Switch with Minimum Contact Gap of 3 mm. Model Number Legend.

D2D. Door Interlock Switch. Ordering Information. Power Switch with Minimum Contact Gap of 3 mm. Model Number Legend. Door Interlock Switch Power Switch with Minimum Contact Gap of 3 mm Offers the minimum contact gap of 3 mm required for power switches as standard equipment. Highly reliable design conforms to European

More information

Light ON 5m. * Light ON. 2.5m (3m) Light ON. (5m)

Light ON 5m. * Light ON. 2.5m (3m) Light ON. (5m) All voltage photoelectric sensors Built-in amplifier accepts wide supply voltage range. Slim, space-saving construction measures only x x 7.4 mm. s with long life expectancy and high switching capacity

More information

A16. Separate Construction with Cylindrical 16-dia. Body. Pushbutton Switch (Detachable) (Lighted/Non-Lighted) (Cylindrical 16-dia.

A16. Separate Construction with Cylindrical 16-dia. Body. Pushbutton Switch (Detachable) (Lighted/Non-Lighted) (Cylindrical 16-dia. Pushbutton Switch (Detachable) (Lighted/Non-Lighted) (Cylindrical 16-dia.) Separate Construction with Cylindrical 16-dia. Body Miniature design of 28.5 mm, the smallest class in the industry. Detachable

More information

Inductive Proximity Sensor

Inductive Proximity Sensor Inductive Proximity Sensor Subminiature Sensor with Cable Amplifier Offers Greater Mounting Flexibility Programmable Controller-compatible Subminiature, shielded sensing head (3 or 8 dia.) allows the Sensor

More information

E2A. Ordering Information. Cylindrical Proximity Sensor. Safe Mounting with Greater Sensing Distance. E2A Cylindrical Proximity Sensor 1

E2A. Ordering Information. Cylindrical Proximity Sensor. Safe Mounting with Greater Sensing Distance. E2A Cylindrical Proximity Sensor 1 Cylindrical Proximity Sensor E2A Safe Mounting with Greater Sensing Distance Ensures a sensing distance approximately 1. to 2 times larger than that of any conventional OMRON Sensor. Problems such as the

More information

7. Approved Standards US: UL, CSA UL: FILE No.E CSA: FILE No.LR31928) 8. Special Function None : Standard U : For ultrasonically cleanable

7. Approved Standards US: UL, CSA UL: FILE No.E CSA: FILE No.LR31928) 8. Special Function None : Standard U : For ultrasonically cleanable Subminiature, Sensitive SPDT Signal Switching Relay High sensitivity: 98-mW (Rated power consumption: mw) pickup coil power. Impulse withstand of 1,V ( 1 μs) meets FCC requirements. Stick packing employed

More information

Ordering Information. I/O Relay G7T. Model Number Legend Slim-styled I/O Relay Saves Space in Panel

Ordering Information. I/O Relay G7T. Model Number Legend Slim-styled I/O Relay Saves Space in Panel I/O Relay CSM DS_E_2_ Slim-styled I/O Relay Saves Space in Panel SPST-NO, SPST-NC, and SPDT contact forms available for output (SPST-NO only for input). Ultra-slim housing measuring 29 (W) x 0 (D) x 2

More information

Compact Magnetic Non-contact Safety Switches. Model Number Structure

Compact Magnetic Non-contact Safety Switches. Model Number Structure Compact Non-contact Safety Switches FS-TGR-N@C Coded Non-contact switches are designed to interlock hinge, sliding or removal guard doors. All coded Non-contact switches have a LED for easy diagnosis.

More information

Appearance Size (mm) Power supply voltage Model (W H D) 100 to 240 VAC K3SC to 240 VAC

Appearance Size (mm) Power supply voltage Model (W H D) 100 to 240 VAC K3SC to 240 VAC Interface Converter A compact converter that allows communications between RS-C/USB and RS-/8 devices. Ideal for industrial applications. Allows communications between RS-C/USB (Universal Serial Bus) and

More information

D2VW. Sealed Miniature Basic Switch. Ordering Information Model Number Legend D2VW- -

D2VW. Sealed Miniature Basic Switch. Ordering Information Model Number Legend D2VW- - Sealed Miniature Basic Switch Sealed Miniature Basic Switch Conforms to IP67 (Molded Lead Wire Type Only) Use of epoxy resin assures stable sealing, making this switch ideal for places subject to water

More information

A K - J 3ML - 2

A K - J 3ML - 2 Key-type Selector Switch A165K Mounting Aperture of 16 mm Modular construction Oil-resistant IP65 models UL and cul approved. Conforms to EN60947-5-1, IEC947-5-1 Short mounting depth, less than 28.5 mm

More information

Installation Sensing distance Connection Output configuration Operation mode NO Operation mode NC

Installation Sensing distance Connection Output configuration Operation mode NO Operation mode NC Standard (thin shape) Inductive Proximity Sensor Thin shape for space saving surface mounting Direct side wall mounting for bracket-less installation Ordering Information DC 3-wire Models Installation

More information

Ordering Information. I/O Relay G7T. Model Number Legend Slim-styled I/O Relay Saves Space in Panel

Ordering Information. I/O Relay G7T. Model Number Legend Slim-styled I/O Relay Saves Space in Panel I/O Relay CSM DS_E_4_4 Slim-styled I/O Relay Saves Space in Panel SPST-NO, SPST-NC, and SPDT contact forms available for output (SPST-NO only for input). Ultra-slim housing measuring 29 (W) x 0 (D) x 2

More information

Time-limit operation/ self-resetting DPDT --- H3M H3M with Y92F-40 adapter SPDT SPDT H3M-H H3M-H with Y92F-40 adapter

Time-limit operation/ self-resetting DPDT --- H3M H3M with Y92F-40 adapter SPDT SPDT H3M-H H3M-H with Y92F-40 adapter Solid-state Timer Solid-state Timer with Variable Time Ranges Four time ranges are selectable per timer unit. Wide timing range of 0.05 second to 30 hours can be covered by a combination of five timer

More information

Long-time range model (0.1 min to 10 h) 24 VAC; SPDT H3RN-1 H3RN-11 12, 24 VDC DPST-NO H3RN-2 H3RN-21

Long-time range model (0.1 min to 10 h) 24 VAC; SPDT H3RN-1 H3RN-11 12, 24 VDC DPST-NO H3RN-2 H3RN-21 Solid-state timer CSM DS_E_3_2 Ultra-slim Timer for G2R Relay Socket Pin configuration compatible with G2R Relay and mounts to the P2R/P2RF Socket. Standard multiple time ranges and multiple operating

More information

NPN output PNP output Cord connection Cord length: 2 m Through-beam 7 m Light-ON. 2 m. (selectable by wiring) Diffuse reflective 0.

NPN output PNP output Cord connection Cord length: 2 m Through-beam 7 m Light-ON. 2 m. (selectable by wiring) Diffuse reflective 0. Built-in Amplifier Photoelectric Sensor E3V3 Easy-to-use, Low-cost Photoelectric Sensor Incorporating s that can be clearly seen from a distance. A series of models with an M8 metal junction connector

More information

Compact Magnetic Non-contact Safety Switches. Model Number Structure

Compact Magnetic Non-contact Safety Switches. Model Number Structure Compact Non-contact Safety Switches Coded Non-contact switches are designed to interlock hinge, sliding or removal guard doors. All coded Non-contact switches have a LED for easy diagnosis. Coded actuator

More information

Thread length. 27 (40) mm. 27 (44) mm. 27 (40) mm. 34 (50) mm. 34 (49) mm. 39 (60) mm. 39 (54) mm. 44 (65) mm. 44 (59) mm

Thread length. 27 (40) mm. 27 (44) mm. 27 (40) mm. 34 (50) mm. 34 (49) mm. 39 (60) mm. 39 (54) mm. 44 (65) mm. 44 (59) mm Long Distance Cylindrical. Extra long for increased protection and sensing performance triple proximity sensors for flush mounting requirements. designed and tested for extra long life. Ordering Information

More information

G3NE. Model Number Structure. Solid State Relays. Model Number Legend. Compact, Low-cost, SSR Switching 5 to 20 A

G3NE. Model Number Structure. Solid State Relays. Model Number Legend. Compact, Low-cost, SSR Switching 5 to 20 A Solid State Relays CSM DS_E_4_1 Compact, Low-cost, SSR Switching 5 to 20 A Wide load voltage range: 75 to 264 VAC. Both 100-V and 200-V loads can be handled with the same model. Dedicated, compact aluminum

More information

Solid-state Timer H3FA. Model Number Structure. DIP Model Timer for PC Board Use Provides Contact and Solid-state Output

Solid-state Timer H3FA. Model Number Structure. DIP Model Timer for PC Board Use Provides Contact and Solid-state Output Solid-state Timer H3FA Please read and understand this catalog before purchasing the products. Please consult OMRON representative if you have any questions or comments. Refer to Warranty and Application

More information

SRT2-ROC08, SRT2-ROC16

SRT2-ROC08, SRT2-ROC16 Ultra-miniature 8-point and 16-point Relaymounted Terminals Ultra-compact (8-point models: 101 x 51 x 51 mm (W x H x D); 16-point models: 156 x 51 x 51 mm (W x H x D)) MOS FET Relay and Relay models. DIN

More information

Miniature Basic Switch

Miniature Basic Switch Miniature Basic Switch Reliable and Safe Basic Switch Self-cleaning contacts. Best-seller Switches with switching currents of 10 to 21 A. Can be used for shutting down current in doors. Widely used for

More information

H3CR-F H3CR-F8 H3CR-F-300 H3CR-F8-300

H3CR-F H3CR-F8 H3CR-F-300 H3CR-F8-300 R Solid-State Repeat-Cycle Timer 1/1 DIN Solid-State Repeat-Cycle Timer Wide power supply ranges of 100 to 240 VAC 24 VAC/VDC, 12VDC Combinations of independent long or short / time settings are possible

More information

Switching Power Supply

Switching Power Supply Switching Power Supply Miniature, Thin Power Supply to Be Built into Equipment Half the size of OMRON s conventional power supply. PCB-type and connector-type models available. UL, CSA approved. Conforming

More information

Contact form. Operating Force. SPDT 25g Unsealed Solder / 187 Quick Connect. SPDT 50g Unsealed Solder / 187 Quick Connect

Contact form. Operating Force. SPDT 25g Unsealed Solder / 187 Quick Connect. SPDT 50g Unsealed Solder / 187 Quick Connect VX Miniature Snap Action Switch Compact snap action switch with low force operation Internal mechanism assures outstanding contact reliability Models available for micro load up through 5 Amps ROHS Compliant

More information

Solid State Relays with Failure Detection Function

Solid State Relays with Failure Detection Function Solid State Relays with Failure Detection Function CSM DS_E_2_1 Refer to Safety Precautions for All Solid State Relays. Detects failures in SSR used for heater temperature control and simultaneously outputs

More information

4 mm. 8 mm. Proximity Sensor. Sensing head Sensing distance Output configuration Part Number M18 Shielded 4 mm DC 3-wire PNP-NO E2EZ-X4B1 M30

4 mm. 8 mm. Proximity Sensor. Sensing head Sensing distance Output configuration Part Number M18 Shielded 4 mm DC 3-wire PNP-NO E2EZ-X4B1 M30 Sensing distance Supply voltage Output 4 mm 8 mm 12 to 24 VDC 100 to 220 VAC 200 ma max. 100 ma max. Proximity Sensor Detects Objects without Being Influenced by Aluminum and Cast Iron Cut Chips Sense

More information

Switching Power Supply

Switching Power Supply Switching Power Supply Highly Reliable and Full-functioned 1-year Life Expectancy, 12, 1, or 24 V output voltages, and 30, 60, 0, or 10 W power ratings. 8 to 132 VAC or 170 to 264 VAC switchable input

More information

D2SW-3L1HS D2SW-01L1HS

D2SW-3L1HS D2SW-01L1HS Sealed Snap Action Switch D2SW Watertight Miniature Snap Action Switch High-quality watertight miniature Snap Action switch. Switch Body meets IP67 (IEC 529) requirements Monoblock construction assures

More information

Cylindrical Proximity Sensor

Cylindrical Proximity Sensor Cylindrical Proximity Sensor A New Series of Easy-to-use and Tough Models with a Yellow Indicator New series of TL-X2C1-GE models with improved performance over the previous TL-X-E models. Also, in addition

More information

G9SX-LM. Low-speed Monitoring Unit. Low-speed Monitoring Function Ensures Safety for Maintenance Work. Model Number Structure.

G9SX-LM. Low-speed Monitoring Unit. Low-speed Monitoring Function Ensures Safety for Maintenance Work. Model Number Structure. Low-speed Monitoring Unit G9SX-LM Low-speed Monitoring Function Ensures Safety for Maintenance Work Motor rotation speed detected by Proximity Sensor. Monitors and confirms that speed does not exceed the

More information

Switching Power Supply S8E1. Ordering Information. Compact and Economical Switching Power Supply

Switching Power Supply S8E1. Ordering Information. Compact and Economical Switching Power Supply Switching Power Supply Compact and Economical Switching Power Supply Models range from 10 to 50 W Open-frame and covered types Wide range of output voltage: 5-, 12-, 15- and 24-V models UL, CSA approved

More information

Ordering Information. Door Interlock Switch D2D. Power Switch with Minimum Contact Gap up to 3 mm. D2D - 0. Model Number Legend

Ordering Information. Door Interlock Switch D2D. Power Switch with Minimum Contact Gap up to 3 mm. D2D - 0. Model Number Legend Door Interlock Switch D2D Power Switch with Minimum Contact Gap up to 3 mm. Minimum contact gap of 3 mm (standard models), needed in general power switches, is provided. Mechanism with double return spring

More information

Note: Each relay to be mounted must incorporate a coil that has proper specifications within the maximum rated voltage range.

Note: Each relay to be mounted must incorporate a coil that has proper specifications within the maximum rated voltage range. I/O Block Base G7A Reduces Wiring while Providing I/O Flexibility Mount I/O relays and I/O SSRs freely. Electric-shock preventive (finger-touch protection) terminal block incorporated conforming to VDE

More information

S8VE (60/90/120/180/240-W Models)

S8VE (60/90/120/180/240-W Models) Switch Mode Power Supply S8VE (60/90/120/180/240-W Models) CSM_S8VE_DS_E_1_1 60/90/120/180/240-W Models Improved Versions of Standard-type Power Supplies without Indication Monitor. Safety standards: UL508/60950-1,

More information

Time-limit contact Time ranges Supply voltage Mounting s to 3 h 24, 100 to 120, 200 to 230 VAC (50/60 Hz); 12, 24, 48, 125, 100 to 110 VDC

Time-limit contact Time ranges Supply voltage Mounting s to 3 h 24, 100 to 120, 200 to 230 VAC (50/60 Hz); 12, 24, 48, 125, 100 to 110 VDC Solid-state Timer CSM DS_E_4_1 Miniature Timer Compatible with the MY Relay Semi-multi power supply voltage. Large transparent time setting knob facilitates time setting. A flat-blade and Phillips screwdriver

More information

16 g SS-01GL-FD SS-01GL-F SS-01GL-FT 50 g SS-01GLD SS-01GLD1 SS-01GLD2 SS-01GL SS-01GLT Simulated roller lever

16 g SS-01GL-FD SS-01GL-F SS-01GL-FT 50 g SS-01GLD SS-01GLD1 SS-01GLD2 SS-01GL SS-01GLT Simulated roller lever Snap Action Switch SS Subminiature Snap Action Switch Economical, subminiature snap action switch offers long service life (30 million operations minimum) All models are free from overtravel restrictions,

More information

G3NE. Ordering Information. Solid State Relay. Compact, Low-cost, SSR Switching 5to20A J ACCESSORIES (ORDER SEPARATELY) Solid State Relay G3NE

G3NE. Ordering Information. Solid State Relay. Compact, Low-cost, SSR Switching 5to20A J ACCESSORIES (ORDER SEPARATELY) Solid State Relay G3NE Solid State Relay G3NE Compact, Low-cost, SSR Switching 5to20A D Wide load voltage range: 75 to 264 VAC. D Dedicated, compact aluminum PCB and power elements used. D Built-in varistor effectively absorbs

More information

E3S-A. Built-in Amplifier Photoelectric Sensor (Medium Size) Ordering Information. Built-in Amplifier Photoelectric Sensors. Horizontal. 7 m.

E3S-A. Built-in Amplifier Photoelectric Sensor (Medium Size) Ordering Information. Built-in Amplifier Photoelectric Sensors. Horizontal. 7 m. Built-in Amplifier (Medium Size) ES-A Be sure to read Safety Precautions on page 0. Ordering Information Built-in Amplifier s Red light Infrared light Sensing method Appearance Connection method Sensing

More information

Snap Action Switch. General- Low force 25 g D2F-FL D2F-FL-T D2F-FL-D D2F-FL-A D2F-FL-A1

Snap Action Switch. General- Low force 25 g D2F-FL D2F-FL-T D2F-FL-D D2F-FL-A D2F-FL-A1 Snap Action Switch Subminiature Snap Action Switch Super compact, ideal for PCB mounting Switches 3 A loads (general-purpose), 1 A loads (low force general-purpose) and 0.1 A loads (microvoltage/microcurrent)

More information

Pin plunger D2JW-011 D2JW-011-MD. Short hinge lever D2JW-01K1A1 D2JW-01K1A1-MD. Hinge lever D2JW-01K11 D2JW-01K11-MD

Pin plunger D2JW-011 D2JW-011-MD. Short hinge lever D2JW-01K1A1 D2JW-01K1A1-MD. Hinge lever D2JW-01K11 D2JW-01K11-MD Sealed Snap ction Switch DJW Immersion-Proof Subminiature Snap ction Switch Ultra-small and highly sealed Water-tight housing conforming to IEC IP67 Wide range of operating temperature from -40 to 85 C

More information

PRODUCT SPECIFICATION. PC Board Relays. Series.

PRODUCT SPECIFICATION. PC Board Relays. Series. PRODUCT SPECIFICATION PC Board Relays 26 Series www.wernerelektrik.com Technical Data... Specifications...2 Model Number Structure - Relays...3 Model Number Selection...4 Dimensions... 5-6 Accessories...7

More information

Model Number Structure

Model Number Structure Temperature Controllers ECS CSM_ECS_DS_E Simple Functions in DIN mm-size Plug-in Temperature Controllers Easy setting using DIP switch. Models with two alarms added to Series, ideal for applications requiring

More information

Model Number Structure

Model Number Structure ASH & ALAIN INDIA PVT LTD S-100, F.I.E.E., Okhla Industrial Area, Phase-ii, New Delhi-110020(India) Tel : 011-43797575 Fax : 011-43797574 E-mail : sales@ashalain.com Solid State Relays G3 @-VD CSM_G3F_G3FD_DS_E_2_1

More information

Terminals Solder terminals Quick-connect. PCB terminals terminals (#110) 3 A Pin plunger SS-3GP SS-3GPT SS-3GPD SS-3GPB

Terminals Solder terminals Quick-connect. PCB terminals terminals (#110) 3 A Pin plunger SS-3GP SS-3GPT SS-3GPD SS-3GPB Subminiature Basic Switch SS-P SS Series Compatible Mounting with a Simple Construction and Easy-to-Use Design Concept Insert molded base and improved case-to-base seal provides enhanced resistance to

More information

Basic Switch. Pin plunger Short hinge Hinge lever Long hinge lever Simulated hinge Short hinge Hinge roller lever lever roller lever lever

Basic Switch. Pin plunger Short hinge Hinge lever Long hinge lever Simulated hinge Short hinge Hinge roller lever lever roller lever lever Basic Switch MINIATURE Watertight Miniature Basic Switch High-quality watertight, high-precision miniature basic switch meets IP67 requirements IEC 529 (lead wire type) Monoblock construction assures high

More information

Contact form. Operating Force. Plunger SPDT 204g Dust- Proof (in closed position) Plunger SPST-NC 204g Dust- Proof (in closed position)

Contact form. Operating Force. Plunger SPDT 204g Dust- Proof (in closed position) Plunger SPST-NC 204g Dust- Proof (in closed position) D3D Miniature Door Switch Appliance industry standard plunger and lever actuator styles High contact reliability ensured using gold alloy crossbar contacts Drip/spill sealing in free position (plunger

More information

Solid-state Timer. Mounting system contact t contact. t Surface mounting/ track mounting

Solid-state Timer. Mounting system contact t contact. t Surface mounting/ track mounting Solid-state Timer DIN-sized (48 x 48, 45 x 75 mm) Timer with Digital Setting and LCD Display Dual power supplies for free AC/DC. Eight operation modes selectable with one unit. Any desired time can be

More information

Ordering Information. Snap Action Switch V. Model Number Legend V General Purpose Snap Action Switch. Snap Action Switch V 121

Ordering Information. Snap Action Switch V. Model Number Legend V General Purpose Snap Action Switch. Snap Action Switch V 121 Snap ction Switch V General Purpose Snap ction Switch Industry standard design with switching currents of 10 to 21 Widely used for applications where long life expectancy and high reliability is required.

More information

E3X-NA. Adjuster type standard that is the culmination of true ease and simplicity. Super Manual Fiber Amplifier. Features

E3X-NA. Adjuster type standard that is the culmination of true ease and simplicity. Super Manual Fiber Amplifier. Features Super Manual Fiber Amplifier Adjuster type standard that is the culmination of true ease and simplicity Features Self-explanatory LED bar displays of light levels The previous manual type used the stability

More information

Combine Relays and P7TF Block Bases to match your application requirements. Use the table below to configure Relay Blocks.

Combine Relays and P7TF Block Bases to match your application requirements. Use the table below to configure Relay Blocks. 9 Relay I/O Block Reduces Wiring within the Control Panel and Reduces Installation Time 1 Compact 16-pt models: 182 W l 85 D l 68 H mm; 8-pt block width is 102 mm 1 Can be connected to the PLC with a connecting

More information

SS Series Compatible Mounting with a Simple Construction and Easy-to-Use Design Concept

SS Series Compatible Mounting with a Simple Construction and Easy-to-Use Design Concept Subminiature Basic Switch SS Series Compatible Mounting with a Simple Construction and Easy-to-Use Design Concept One-piece terminal construction to keep out flux. A single leaf movable spring construction.

More information

Voltage Current Front-mounting bracket

Voltage Current Front-mounting bracket Switching Power Supply S8PS Compact DIN-Rail Mounting Industrial Power Supplies with Capacities Up to 600 W Models range from 0 W to 600 W. Universal input: voltage range 0 to 240 VAC. Power Factor Correction

More information

Conductive Level Controller

Conductive Level Controller Conductive Level Controller 61F-D21T-V1 Ideal for level control for industrial facilities and equipment. Outputs can be set to self-hold at ON or OFF using self-holding circuits. Sensitivity adjustment

More information

Photoelectric Sensor. Threaded Cylindrical Photoelectric Sensors with Built-in Amplifier for Use as an Optical Proximity Sensor

Photoelectric Sensor. Threaded Cylindrical Photoelectric Sensors with Built-in Amplifier for Use as an Optical Proximity Sensor Photoelectric Sensor Threaded Cylindrical Photoelectric Sensors with Built-in Amplifier for Use as an Optical Proximity Sensor M1 DIN-sized cylindrical housing Housing materials: plastic, nickel-brass,

More information

masterelectronics.com onlinecomponents.com

masterelectronics.com onlinecomponents.com Basic Switch MINIATURE Watertight Miniature Basic Switch High-quality watertight, high-precision miniature basic switch meets IP67 requirements (IEC 529) Monoblock construction assures high sealing capability

More information

Ordering Information. Three-phase Input Switch Mode Power Supply S8VT S8VT. Model Number Legend

Ordering Information. Three-phase Input Switch Mode Power Supply S8VT S8VT. Model Number Legend Three-phase Input Switch Mode Power Supply S8VT DIN-rail mounting, Power Supply with a range of 5 A to 40 A output current 3 phase 400 to 500 VAC 5, 10, 20 and 40 A; 24 VDC output Higher stability, lower

More information

Conforms to VDE0435/2021 C/250, VDE0110, VDE0106/P100 Conforms to EN , pren

Conforms to VDE0435/2021 C/250, VDE0110, VDE0106/P100 Conforms to EN , pren Solid-state Power OFF-delay Timer II DIN 22.5-mm Solid-state Power OFF-delay Timer High immunity to invertor noise. Long power OFF-delay times; S-series: up to 12 seconds, L-series: up to 120 seconds.

More information

Sensing method Appearance Connection method Sensing distance Part number NPN output PNP output Through-beam Prewired (2 m) E3Z-T61A E3Z-T81A 10 m

Sensing method Appearance Connection method Sensing distance Part number NPN output PNP output Through-beam Prewired (2 m) E3Z-T61A E3Z-T81A 10 m Through-Beam Sensor with Visible Red LED Visible Beam Allows Visual Confirmation of the Detection Spot, for Easy Installation and Maintenance Built-in amplifier Mutual interference protection filter included

More information

Ordering Information. Smart Sensors (Inductive Displacement Type) ZX Series. Sensors

Ordering Information. Smart Sensors (Inductive Displacement Type) ZX Series. Sensors Smart Sensors (Inductive Displacement Type) ZX Series Smart Sensors that use the eddy current method are now available. Develop new applications with sub-micron sensing technology.. Ordering Information

More information

Model Number Structure

Model Number Structure Temperature Controllers Easy Setting Using DIP Switch and Simple Functions in DIN mm-size Temperature Controllers Easy setting using DIP switch. Models with two alarms added to Series, ideal for temperature

More information

Terminal Relay types. Common note. Terminal Relay/Terminal SSR Mounted relays. Compact Terminal Relays/Terminal SSRs with four outputs

Terminal Relay types. Common note. Terminal Relay/Terminal SSR Mounted relays. Compact Terminal Relays/Terminal SSRs with four outputs Terminal Relay/Terminal SSR G6B-@@ND/G3S CSM_G6B- ND_G3S_DS_E Compact Terminal Relays/Terminal SSRs with four outputs Easy wiring with separated input/output terminals. LED operation indicator. Mounts

More information

Thread length (overall length)

Thread length (overall length) Cylindrical Proximity Sensor E2A Safe Mounting with Greater Sensing Distance Ensures a sensing distance approximately 1. to 2 times larger than that of any conventional OMRON Sensor. Problems such as the

More information

Model Number Structure

Model Number Structure Solid State Relays with Failure Detection Function Refer to Safety Precautions for All Solid State Relays. Detects failures in SSR used for heater temperature control and simultaneously outputs alarm signal.

More information

Switch Mode Power Supply S8VT 120/240/480/960 W Models

Switch Mode Power Supply S8VT 120/240/480/960 W Models Switch Mode Power Supply 120/240/480/960 W Models Natural Cooling Three-phase Power Supply Range from 5A up to 40A with Output Voltage of 24VDC 3 phase 400 to 500 VAC 5, 10, 20 and 40 A; 24 VDC output

More information

E4PA. Ultrasonic Displacement Sensor. Ordering Information

E4PA. Ultrasonic Displacement Sensor. Ordering Information Ultrasonic Displacement Sensor Ideal for controlling liquid level. Long sensing distance and high-resolution analog output. High-precision detection with a wide range of measurements Four types of Sensors

More information

NE1A/DST1. DeviceNet Safety System

NE1A/DST1. DeviceNet Safety System System Omron now offers a DeviceNet compatible Safety System, that can be used 3-ways: as a Standalone controller, as a Safety network expandable with remote I/O blocks, or combined with DeviceNet to form

More information

Programmable Relay ZEN V2 Units

Programmable Relay ZEN V2 Units Programmable Relay ZEN V2 Units Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Refer to Warranty

More information