Easy Networking for Power Monitoring. network based MONITORING SOLUTIONS

Size: px
Start display at page:

Download "Easy Networking for Power Monitoring. network based MONITORING SOLUTIONS"

Transcription

1 Easy Networking for Power Monitoring network based MONITORING SOLUTIONS

2 Monitoring Real-Time Power Information with Internet Explorer The ability to network an electrical distribution system is an overlooked asset in the design of electrical systems. With today s technology, however, many of the cost adders and most of the complexity have disappeared. The Siemens 9510 and 9610 power quality meters come with standard functionality which enables them to be used as local displays, data loggers, and as web servers allowing remote users to access electrical system data with only their internet browser. At the center of this system is the meter s ability to be a Modbus Master Device. This means the power meter requests data from any Modbus serial device, like the Siemens 9200 Power Meter or WL Power Circuit Breakers. The Central Display and Remote Monitoring functionality is provided in the Siemens devices and once the meters and other devices are installed and interconnected in the distribution equipment, customers then only need to provide a static IP address to program into the 9510/9610 power meter. Inputting the IP address can be done from the front display panel without any configuration software. Your system is now ready for use. Standard Ethernet Network RS 485 Modbus 9510/9610 Power Meter and Web Based Local Display Cat. 5e or Fiber Digital Inputs Qty 16 (optional) To Breaker aux. contacts for OPEN/CLOSE and TRIP Status 9510/9610 Power Meter with local display and web server capabilities WL Breaker Trip Unit Types ETU 745, 748, 755, or 776 with Modbus communication and metering capabilities 9200 Power Meter with full metering capabilities and individual display 9200 Power Meter with full metering capabilities and no display (information displayed at the main meter) 9510/9610 has 16 digital inputs which are available for circuit breaker open/close and trip status, or transfer switch status, transformer alarms, or any other equipment status the customer may require (serial cabling by factory) Option A WL Breaker ETU 745 ETU 748 ETU 755 ETU 776 WL Breakers with Electronic Trip Units Option B 9200 Meters 9200 Power Meters with Display 9200 Power Meters without Display Option C 9200 Tran Meters * Any combination of the above

3 Option A When using the LV switchgear design, by utilizing the ETU 7 series with the metering plus module and Modbus communications, the following values are available to be displayed at the power meter and over the web from the meter s web pages. Parameters Per Phase and Average Current Values Current Demand Per Phase and Average Voltage Values KVA Total KW and KW Demand KVAR Total Frequency Energy, Kwhr delivered and received Power Factor Total Harmonic Distortion Neutral and Ground Currents Current and Voltage Unbalance Spring Charge Status Breaker Status (OPEN/CLOSE) RTC Flag Status (Ready to Close) Trip Indication (Tripped/Not Tripped) Option B When using switchboard design, there are two options for metering the feeder breakers. If an individual display is required for each of the feeders, then the 9200 meter with display can be used on each feeder. Option C If the main 9510/9610 meter is going to be used as the local display, then there is the option to use the 9200 meter without display. In each case, Option B or C, the following parameters are available at the branch device. Parameters Per Phase and Average Current Values Current Demand Per Phase and Average Voltage Values KVA Total KW and KW Demand KVAR Total Frequency Energy, Kwhr delivered and received Power Factor Total Harmonic Distortion System Overview Figures 1.1 through 1.4 on following page show four standard screens for the power meters, real-time, revenue measurements, set-up, and network set-up, respectively. Figures 1.5 and 1.6 are custom web pages created within the 9510 or 9610, based on customer requirements and project specific information for both the WL breakers and the 9200 power meters. This customization is done at the time of commissioning and does not require additional software.

4 9510 or 9610 Real-time Web Screen Internet Explorer allows you to view real-time power system information from the 9510 or 9610 power meters. Your internet browser automatically polls the selected device(s) and updates the displayed measurements in your browser window. It runs entirely on the client side so you don t need to install anything special on your PC or 9610 Revenue Measurements/Energy Web Screen The Revenue Measurements page is pre-configured to display important data such as real, reactive, and apparent power. Figure or 9610 Basic Set-up Screen Figure or 9610 Network Set-up Page, Password Protected The Setup screen allows the user to easily configure the basic meter settings without any additional software. Figure 1.3 Custom Web Pages The 9510/9610 meter has the ability to poll data from downstream devices, like WL breakers on feeders or 9200 power meters on feeder breakers and then display this data in custom web pages. WL breaker data displayed remotely using the 9510 or 9610 as a web server. Figure Real-time Data Displayed Remotely Using the 9510 or 9610 as a Web Server Figure 1.5 Figure 1.6

5 Typical 9510/9610 Local Display Examples 9200 meter data at a 9510/9610 meter, twenty parameter screen Submeter 05/30/ :35:14 VIn avg VII avg I avg I dmd Freq PF sign tot V1 THD 0.00 V2 THD 0.00 V3 THD 0.00 Figure 2.1 kw tot kvar tot kva total kw pk dmd kvar pk d kva pk dm kwh del kvarh kvah TOU Dmd1 TOU Dmd STIII CP STIII CP 9200 feeder monitoring individual current values on an eight parameter display, including sliding window demand (SWD) and the maximum values. ATS 3 01/22/ :33:33 lavg SWD Amps A Amps B Amps C Current Avg Brk Pos Figure Closed lavg SWD Max lavg max TOU Dmd1 TOU Dmd2 PCC ATS 3 DPPS1A 9200 feeder monitoring individual current values and displaying 4 parameters and their minimum values and their maximum values by the arrows FDR 1 05/30/ :59:19 la lb lc l avg Figure 2.3 FDR It is possible to connect up to twenty 9200 power meters or twenty WL breakers or a combination of both to one meter s Modbus master port. Figures 2.1, 2.2 and 2.3 show various display configurations when applying the main meter s local display capabilities. The actual number of devices and parameters to be displayed is dependent upon the number of parameters to be displayed per device. The sample topology shown on the previous page depicts the connections to either 9200 meters or to WL breakers. All wiring and configuration is done at the factory, leaving only the IP address programming to be completed in the field. Siemens Performance Specification Feeder circuits shall include communications and shall be factory wired to the Ethergate port (Ethernet comm. card) of the 9510 / 9610 Power Quality meter. The meter shall be factory configured to log, display, and make available via HTML web pages real time data, power quality information, and revenue data from each of the feeder breakers, without requiring any separate windows based operating software. Display the parameters on one screen per feeder at the meter and on one web page per meter remotely at the client s computer using only Internet Explorer. Exact screen layouts will depend on parameter configuration done at commissioning.

6 Additional Capabilities Water, Air, Gas, and Steam Monitoring The digital inputs supplied with the 9510 or 9610 power meters can be configured for pulse counting applications where full utility monitoring is required. Now, gas, water, air, and steam pulses can be collected in one unit, logged and displayed. Up to 16 digital inputs can be configured. Wages: Water and Ga 01/22/ :49:58 Water Flow GPH WaterSWinDemand CFH GasSWinDemand Analog V Memory STIII 9200 Wages MeterM@il Meters equipped with an Ethernet port can automatically alarm notifications or scheduled system-status updates. MeterM@il messages can be received like any message, at a workstation, cellphone, pager or PDA. Data logs can also be sent on an event-driven or scheduled basis via , while conveniently accommodating firewall restrictions. XML Compatibility The units can also exchange information using industry-standard XML format. It s simple machine readable-format supports easy integration with custom reporting, spreadsheet, database, and other applications. XML Alarm Real Time Siemens Energy & Automation, Inc Old Milton Parkway Alpharetta, GA info.sea@siemens.com Siemens Energy & Automation, Inc. All Rights Reserved. Siemens is a registered trademark of Siemens AG. Product names mentioned may be trademarks or registered trademarks of their respective companies. Specifications are subject to change without notice. PMBR-NBM-0906 New 5M0906B&A Printed in USA

PowerLogic ION7300 Series

PowerLogic ION7300 Series PowerLogic ION7300 Series Power & Energy Meter User Guide October 2007 Notices Danger Caution This symbol indicates the presence of dangerous voltage within and outside the product enclosure that may

More information

Product Overview. Power Distribution Solutions. Answers for industry.

Product Overview. Power Distribution Solutions. Answers for industry. Product Overview Power Distribution Solutions Answers for industry. WinPM.Net Power Monitoring and Control Software Siemens web-enabled, open and flexible, reporting analysis tool for electrical engineers,

More information

Equipment Operation & Maintenance

Equipment Operation & Maintenance Equipment Operation & Maintenance Many Facilities have: Very complex distribution systems. Many inter-locked backup power systems. Maintaining and troubleshooting the complex distribution system requires

More information

DNP3 Communications Protocol

DNP3 Communications Protocol Powermeter and Power Quality Analyzer PM174 DNP3 Communications Protocol Reference Guide BG0413 Rev. A3 Every effort has been made to ensure that the material herein is complete and accurate. However,

More information

Usage of the digital inputs of SENTRON PACs

Usage of the digital inputs of SENTRON PACs 1 QUESTION Where and how can I use the digital inputs of the SENTRON PAC meters? What are the guidelines and restrictions? 2 ANSWER The digital inputs (DIs) of the SENTRON PACs can be separated into Dry

More information

PowerLogic ION7550 / ION7650

PowerLogic ION7550 / ION7650 PowerLogic ION7550 / ION7650 Energy & Power Quality Meter User Guide 12/2007 Notices Danger Caution This symbol indicates the presence of dangerous voltage within and outside the product enclosure that

More information

The PowerLogic range. Gain energy insight and control

The PowerLogic range. Gain energy insight and control The PowerLogic range Gain energy insight and control The PowerLogic advantage PowerLogic is the world's largest and most advanced range of software and metering products for managing energy, giving suppliers

More information

Technical data sheet. PowerLogic power-monitoring units EM3500 series DIN Rail meter

Technical data sheet. PowerLogic power-monitoring units EM3500 series DIN Rail meter Technical data sheet PowerLogic power-monitoring units series DIN Rail meter The Series DIN Rail Meter combines exceptional performance and easy installation to deliver a cost-effective solution for power

More information

AcuRev Multi-Circuit Power and Energy Meter. Shop for Accuenergy products online at:

AcuRev Multi-Circuit Power and Energy Meter.   Shop for Accuenergy products online at: AcuRev 2000 Multi-Circuit Power and Energy Meter ISO9001 Certified Comply to IEC 62053-21 Measurement Standard Support up to 18 Individual Channels for Energy Measurement Multifunction Power Metering,

More information

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017 SECTION 26 2713 ELECTRICITY METERING PART 1 - GENERAL 1.1 SUMMARY A. Section includes equipment for metering of the electrical power system. B. Related Sections: 1. Section 26 2300 for metering installed

More information

Specification for Smart Panels : Energy management system to monitor, control and maintain building installations

Specification for Smart Panels : Energy management system to monitor, control and maintain building installations Specification for : Energy management system to monitor, control and maintain building installations The specification describes functionalities and technical features of an Energy management system for

More information

EM-1000 /EM-2000/ EM-3000 Series Multifunction Power and Energy Meters

EM-1000 /EM-2000/ EM-3000 Series Multifunction Power and Energy Meters Power and Energy Meters Code No. LIT-1900845 Issued December 4, 2013 EM-1000 /EM-2000/ EM-3000 Series Multifunction Power and Energy Meters EM-1000 Series Meter Description The EM-1000 Series monitor is

More information

EMS_ _Measure_MonoPh_R_2P_ModbusTable_LG_EN_v1.01.xlsx

EMS_ _Measure_MonoPh_R_2P_ModbusTable_LG_EN_v1.01.xlsx EMS_ 19 19_Measure_MonoPh_R_2P_ModbusTable_LG_EN_v1.01.xlsx GENERAL MODBUS TABLE ORGANIZATION Starting of the Group Starting of the Group System Version System Version Group Name (Text) Group Code Group

More information

9700 Power Meter. User s Guide

9700 Power Meter. User s Guide 9700 Power Meter User s Guide Electrical equipment contains hazardous Voltages and high speed moving parts. Can cause death, serious personal injury, or equipment damage. Always de-energize and ground

More information

PowerLogic series meter

PowerLogic series meter PowerLogic series meter A cost-effective, entry-range power and energy meter Erez domani 23/5/2011 1 A PowerLogic system can help you Improve energy efficiency and lower emissions Maximize the use of power

More information

AcuRev 2000 Multi-Circuits Networked Multifunction Power and Energy Meter

AcuRev 2000 Multi-Circuits Networked Multifunction Power and Energy Meter AcuRev 2000 Multi-Circuits Networked Multifunction Power and Energy Meter AcuRev 2000 Multi-Circuits Networked Multifunction Power and Energy Meter IEC and ANSI Revenue Grade Accuracy Measurement Standard

More information

EM300 Series. ET300 Series

EM300 Series. ET300 Series EM300 Series and ET300 Series COMMUNICATION PROTOCOL Version 2 Revision 11 Index 1.1 Introduction... 3 1.2 MODBUS functions... 3 1.2.1 Function 03h (Read Holding Registers)... 3 1.2.2 Function 04h (Read

More information

DIN Rail Smart Meter for Single and Three Phase Electrical Systems

DIN Rail Smart Meter for Single and Three Phase Electrical Systems SDM630-Modbus V2 DIN Rail Smart Meter for Single and Three Phase Electrical Systems Measures kwh Kvarh, KW, Kvar, KVA, P, F, PF, Hz, dmd, V, A, etc. Bi-directional measurement IMP & EXP Two pulse outputs

More information

Acuvim II Series Power Meter SNMP Protocol User's Manual

Acuvim II Series Power Meter SNMP Protocol User's Manual Acuvim II Series Power Meter SNMP Protocol User's Manual Copyright 2018 V2.00 This manual may not be altered or reproduced in whole or in part by any means without the expressed written consent of Accuenergy.

More information

AcquiSuite Ally 48 Advanced Branch Circuit Monitor

AcquiSuite Ally 48 Advanced Branch Circuit Monitor AcquiSuite Ally 48 Advanced Branch Circuit Monitor AMC48-MD AMC48-ED Split Core CT Split Core CT Ally Rogowski Rope CT DESCRIPTION The AcquiSuite Ally 48 is the perfect companion to the data acquisition

More information

Electronic Submeter with Advanced WiFi Ethernet Capability

Electronic Submeter with Advanced WiFi Ethernet Capability SH RK 100S Electronic Submeter with Advanced WiFi Ethernet Capability AGGRESSIVE TECHNOLOGY W NEIndustry Leading Technology High Performance Metering Technology 0.2% Accuracy Class Revenue Certifiable

More information

Digital Multifunction Meters. Digital Multifunction Meters

Digital Multifunction Meters. Digital Multifunction Meters Digital Multifunction Meters Digital Multifunction Meters DIGITAL MULTIFUNCTIOL METERS SECTION INDEX 1. MFM 3410 3420 3430 3440 6100 & 2000 - Multifunctional Instrument Series 2. EM 3490, 3490SS, 3490DS

More information

ABB SACE A division of ABB S.p.A. L.V. Breakers Via Pescaria 5, Bergamo - Italy Phone: Fax:

ABB SACE A division of ABB S.p.A. L.V. Breakers Via Pescaria 5, Bergamo - Italy Phone: Fax: ABB SACE A division of ABB S.p.A. L.V. Breakers Via Pescaria 5, 24123 Bergamo - Italy Phone: +39 035 395.111 Fax: +39 035 395.306-433 abb.com/lowvoltage Copyright 2017 ABB. All rights reserved. Specifications

More information

MODULAR CIRCUIT MONITORING SYSTEM

MODULAR CIRCUIT MONITORING SYSTEM MODULAR CIRCUIT MONITORING SYSTEM Contact Anord Mardix (USA) Inc. 3930 Technology Court Sandston, VA 23150 Email: us.sales@anordmardix.com Call: +1 800 228 4689 www.linkedin.com/company/anordmardix www.twitter.com/anordmardix

More information

GNM3D Series COMMUNICATION PROTOCOL. Version 1 Revision 0

GNM3D Series COMMUNICATION PROTOCOL. Version 1 Revision 0 GNM3D Series COMMUNICATION PROTOCOL Version 1 Revision 0 Index 1.1 1.2 Introduction... 3 MODBUS functions... 3 1.2.1 Function 03h (Read Holding Registers)... 3 1.2.2 Function 04h (Read Input Registers)...

More information

SDM630M CT USER MANUAL 2016 V4.7. DIN Rail Energy Meter for Single and Three Phase Electrical Systems

SDM630M CT USER MANUAL 2016 V4.7. DIN Rail Energy Meter for Single and Three Phase Electrical Systems SDM630M CT DIN Rail Energy Meter for Single and Three Phase Electrical Systems Measures kwh Kvarh, KW, Kvar, KVA, P, F, PF, Hz, dmd, V, A, THD,etc. Bi-directional measurement IMP & EXP Two pulse outputs

More information

URC Utility Relay Company

URC Utility Relay Company communications i-comm modbus / rs-485 AC-PRO Communicating Trip Units instruction manual ZERO-Hertz Communicating Trip Units URC Utility Relay Company Chagrin Falls, OH 44023 Phone: 888.289.2864 www.utilityrelay.com

More information

SCC Inc. TS Series. Technical Instructions Document No. TS-1050 March 10, TS Serial Communication Kits for use with LMV3, LMV5, and RWF Controls

SCC Inc. TS Series. Technical Instructions Document No. TS-1050 March 10, TS Serial Communication Kits for use with LMV3, LMV5, and RWF Controls SCC Inc. TS Serial Communication Kits for use with LMV3, LMV5, and RWF Controls Technical Instructions March 10, 2017 Description A TS series serial communication kit connects a Siemens LMV linkageless

More information

PM130 PLUS Powermeter Series PM130P/PM130E/PM130EH

PM130 PLUS Powermeter Series PM130P/PM130E/PM130EH PM130 PLUS Powermeter Series PM130P/PM130E/PM130EH Installation and Operation Manual BG0425 Rev. A11 LIMITED WARRANTY The manufacturer offers the customer a 24-month functional warranty on the instrument

More information

SERIES PM172EH POWERMETERS COMMUNICATIONS REFERENCE GUIDE

SERIES PM172EH POWERMETERS COMMUNICATIONS REFERENCE GUIDE SERIES PM172EH POWERMETERS COMMUNICATIONS Modbus Communications Protocol REFERENCE GUIDE Every effort has been made to ensure that the material herein is complete and accurate. However, the manufacturer

More information

BFM-II BFM-II BRANCH FEEDER MONITOR. Highlights

BFM-II BFM-II BRANCH FEEDER MONITOR. Highlights BRANCH FEEDER MONITOR SATEC s is the second generation of Branch Feeder Monitor, providing energy management for multi-point power solutions. Ideal for both new and retrofit projects, the automatically

More information

USER MANUAL 2012 V1.1

USER MANUAL 2012 V1.1 SMART MINI POWER SDM630 USER MANUAL 2012 V1.1-1 - Installation and Operation Instructions Important Safety Information is contained in the Maintenance section. Familiarise yourself with this information

More information

ACUREV 2000 Multi-Circuits Networked Multifunction Power Energy Meter

ACUREV 2000 Multi-Circuits Networked Multifunction Power Energy Meter ACUREV 2000 Multi-Circuits Networked Multifunction Power Energy Meter ISO9001 Certified AcuRev 2000 Multi-Circuits Networked Multifunction Power and Energy Meter IEC and ANSI Revenue Grade Accuracy Measurement

More information

HMI software. gems 3100 Multi-Channel Power Meter

HMI software. gems 3100 Multi-Channel Power Meter HMI software gems 3100 Multi-Channel Power Meter gems 3100 installed in local distribution panels as well as a main electric distribution panel has the features to manage facilities by metering and monitoring

More information

i-meter EM Series & i-meter MF Series Installation and User Manual

i-meter EM Series & i-meter MF Series Installation and User Manual i-meter EM Series & i-meter MF Series Installation and User Manual 1125 Squires Beach Road, Pickering, Ontario L1W 3T9 ph.905-839-9199 f. 905-839-9198 service@intellimeter.on.ca www.intellimeter Rev 1.0

More information

MONITORING AND CONTROL REQUIREMENTS FOR DISTRIBUTED GENERATION FACILITIES

MONITORING AND CONTROL REQUIREMENTS FOR DISTRIBUTED GENERATION FACILITIES MONITORING AND CONTROL REQUIREMENTS FOR DISTRIBUTED GENERATION FACILITIES 1. Introduction Real time monitoring and control is necessary to ensure public and employee safety and to protect the integrity

More information

UMG 511. Class A EN UMG 511 Class A power quality analyzer. according to EN50160, IEEE 519, ITIC, IEC Areas of application

UMG 511. Class A EN UMG 511 Class A power quality analyzer. according to EN50160, IEEE 519, ITIC, IEC Areas of application UMG 511 Class A EN 50160 UMG 511 Class A power quality analyzer according to EN50160, IEEE 519, ITIC, IEC 61000-4-30 The UMG 511 power quality analyzer is particularly suitable for monitoring power quality

More information

9200 Power Meter. Installation & Operation Guide

9200 Power Meter. Installation & Operation Guide 9200 Power Meter Installation & Operation Guide Notices Danger This symbol indicates the presence of dangerous voltage within and outside the product enclosure that may constitute a risk of electric shock,

More information

PMC 530 Series Advanced Multifunction Meter

PMC 530 Series Advanced Multifunction Meter IEC 62053 22 Class 0.5S WF Capture @ 128 samples/cycle WF and Data Recording Harmonics & Transient Monitoring I residual Monitoring Setpoint Alarms, SOE Log RS 485 and I/O Capabilities Large, Bright, Backlit

More information

SDM530-Modbus USER MANUAL 2015 V1.5. Three Phase Multi-function DIN rail meter. Eastron SDM530-Modbus User Manual

SDM530-Modbus USER MANUAL 2015 V1.5. Three Phase Multi-function DIN rail meter. Eastron SDM530-Modbus User Manual SDM530-Modbus Three Phase Multi-function DIN rail meter Measures kwh Kvarh, KW, Kvar, KVA, P, F, PF, Hz, dmd, V, A, etc. Bi-directional measurement IMP & EXP Two pulse outputs RS485 Modbus Din rail mounting

More information

PM135 Powermeter Series PM135P/PM135E/PM135EH

PM135 Powermeter Series PM135P/PM135E/PM135EH PM135 Powermeter Series PM135P/PM135E/PM135EH Installation and Operation Manual BG0518 Rev. A3 LIMITED WARRANTY The manufacturer offers the customer a 24-month functional warranty on the instrument for

More information

SERIES PM172 POWERMETERS COMMUNICATIONS REFERENCE GUIDE

SERIES PM172 POWERMETERS COMMUNICATIONS REFERENCE GUIDE SERIES PM172 POWERMETERS COMMUNICATIONS Modbus Communications Protocol REFERENCE GUIDE Every effort has been made to ensure that the material herein is complete and accurate. However, the manufacturer

More information

NEW Industry Leading Technology. Includes Modbus and DNP 3.0 A G G R E S S I V E T E C H N O L O G Y. High End Meter Performance

NEW Industry Leading Technology. Includes Modbus and DNP 3.0 A G G R E S S I V E T E C H N O L O G Y. High End Meter Performance Includes Modbus and DNP 3.0 Shark 100T Transducer Only NEW Industry Leading Technology High End Meter Performance Low End Economical Pricing Our Easiest to Use Meter Ever! Shark 100 Meter/Transducer A

More information

Three-Phase Power Quality Analyzer PowerPad Model 3945

Three-Phase Power Quality Analyzer PowerPad Model 3945 Three-Phase Power Quality Analyzer PowerPad Model 3945 Wouldn t it be nice if you could look inside your electrical system and see what s going on? Troubleshooting would be so much easier if you could

More information

NEW ERA METER. Installation & Operation Guide NE METER

NEW ERA METER. Installation & Operation Guide NE METER NEW ERA METER Installation & Operation Guide NE METER Autoranging Power Supply Installation Diagnostics Per Phase Voltage & Current kwh, Demand and TOU 0.2% Accuracy -40 C to +85 C Watertight Enclosure

More information

DEIF A/S. MIC Multi-instrument G. Data sheet. Features. Accuracy. Measurements. Installation. Intelligent. Display. Communication DEIF A/S

DEIF A/S. MIC Multi-instrument G. Data sheet. Features. Accuracy. Measurements. Installation. Intelligent. Display. Communication DEIF A/S Multi-instrument 4921210107G Features Measurements All 3-phase AC measurements True RMS Replaces analogue meters Intelligent Suitable for all 3-phase network topologies Replaces transducers Accuracy U,

More information

USER S MANUAL. XPERT Electrical Power Meter. Trinity Energy Systems Pvt. Ltd. TRINITY. Xpert Operational Manual

USER S MANUAL. XPERT Electrical Power Meter. Trinity Energy Systems Pvt. Ltd. TRINITY. Xpert Operational Manual USER S MANUAL XPERT Electrical Power Meter This document contains the latest technical information about Xpert which is a microcontroller based Electrical Power Meter. The product Xpert is sophisticated

More information

PowerLogic ION7300 Profibus DP. Serial Communications Protocol October 2006

PowerLogic ION7300 Profibus DP. Serial Communications Protocol October 2006 PowerLogic ION7300 Profibus DP Serial Communications Protocol October 2006 The information contained in this document is believed to be accurate at the time of its publication; however, assumes no responsibility

More information

NEW MODERNSTE TECHNOLOGIE. Elektronische Messgeräte mit hoher WiFi Ethernet Leistungsfähigkeit. Führende Technologie in der Industrie

NEW MODERNSTE TECHNOLOGIE. Elektronische Messgeräte mit hoher WiFi Ethernet Leistungsfähigkeit. Führende Technologie in der Industrie SH RK 100S Elektronische Messgeräte mit hoher WiFi Ethernet Leistungsfähigkeit NEW MODERNSTE TECHNOLOGIE Führende Technologie in der Industrie Sehr anspruchsvolle Messtechnik Genauigkeitsklasse 0.2% Synchronisierimpuls

More information

SECTION ELECTRIC METERING

SECTION ELECTRIC METERING SECTION 26 27 13 ELECTRIC METERING SPEC WRITER NOTES: Use this section only for NCA projects Delete between //----// if not applicable to project. Also delete any other item or paragraph not applicable

More information

ISGS. Intelligent SwitchGear System The Flexible Solution

ISGS. Intelligent SwitchGear System The Flexible Solution TM ISGS Intelligent SwitchGear System The Flexible Solution Multi-Function Flexibility At The Touch Of A Key Siemens introduces the ISGS Intelligent SwitchGear System a remarkable new development in switchgear

More information

MPQ2000. Portable Power Quality Analyzer. IEC Class A compliance. Powered off of phase A voltage ac/dc Vac and 1000 Vdc range

MPQ2000. Portable Power Quality Analyzer. IEC Class A compliance. Powered off of phase A voltage ac/dc Vac and 1000 Vdc range MPQ2000 IEC61000-4-30 Class A compliance Powered off of phase A voltage ac/dc 1000 Vac and 1000 Vdc range Real time scope and DVM Connection verification On-board data analysis DESCRIPTION The Megger MPQ2000

More information

How Do You Reduce Energy Costs And Prolong The Life Of Your Equipment?

How Do You Reduce Energy Costs And Prolong The Life Of Your Equipment? How Do You Reduce Energy Costs And Prolong The Life Of Your Equipment? PowerLogic PM800 series power meters Buildings Industry Data Center DATA CENTER SOLUTIONS For More Information: (866) 787-3271 Sales@PTSdcs.com

More information

B+G E-Tech User Manual for SDM630 SDM630. Din Rail Smart Energy Meter for Single and Three Phase Electrical Systems USER MANUAL 2013 V1.

B+G E-Tech User Manual for SDM630 SDM630. Din Rail Smart Energy Meter for Single and Three Phase Electrical Systems USER MANUAL 2013 V1. SDM630 Din Rail Smart Energy Meter for Single and Three Phase Electrical Systems USER MANUAL 203 V. Important Safety Information is contained in the Maintenance section. Familiarize yourself with this

More information

Grid Automation Controller COM600 How it fits into the Smart Grid?

Grid Automation Controller COM600 How it fits into the Smart Grid? ABB Oy Distribution Automation Grid Automation Controller How it fits into the Smart Grid? May 27, 2014 Slide 1 1MRS756763 E Content Technical Presentation May 27, 2014 Slide 2 Description Grid Automation

More information

PMC-630 Series Advanced Multifunction Meter

PMC-630 Series Advanced Multifunction Meter IEC 62053-22 Class 0.5S Compliant 2MB Log Memory Power Quality Monitoring Waveform Recording SOE Log Setpoint Alarms RS-485 and I/O Capabilities I residual Monitoring Large, Bright, Backlit LCD Display

More information

SDM530CT-Modbus USER MANUAL 2015 V1.6. Three Phase Multi-function DIN rail meter. Eastron SDM530CT-Modbus User Manual

SDM530CT-Modbus USER MANUAL 2015 V1.6. Three Phase Multi-function DIN rail meter. Eastron SDM530CT-Modbus User Manual SDM530CT-Modbus Three Phase Multi-function DIN rail meter Measures kwh Kvarh, KW, Kvar, KVA, P, F, PF, Hz, dmd, V, A, etc. Bi-directional measurement IMP & EXP Two pulse outputs RS485 Modbus Din rail mounting

More information

UMG 20CM. 20 Channel Branch Circuit Monitoring Device with RCM

UMG 20CM. 20 Channel Branch Circuit Monitoring Device with RCM 20 Channel Branch Circuit Monitoring Device with RCM RCM Harmonics via analysis channel Alarm management GridVis Analysis software 20 current channels Interfaces / communication RS485 RTU Accuracy of measurement

More information

EMDX3 Multifunction meter Cat No ModbusTable LGR EN v1.01.xls

EMDX3 Multifunction meter Cat No ModbusTable LGR EN v1.01.xls GENERAL MODBUS TABLE ORGANIZATION Starting of the Starting of the Group s Group s System Version (Release) System Version (Build) Group Name (Text) Group Code Group Complexity Group Version 36096 8D00

More information

SDM120C. Single-Phase Energy Meters. RS485 Modbus RTU. User Manual V1.0

SDM120C. Single-Phase Energy Meters. RS485 Modbus RTU. User Manual V1.0 SDM120C Single-Phase Energy Meters RS485 Modbus RTU Measures kwh, Kvarh, KW, Kvar, KVA, PF, Hz, dmd, V, A, etc. Di-directional measurement IMP & EXP Two pulse outputs RS485 Modbus Din rail mounting 17.5mm

More information

UW Purchase Specification Section

UW Purchase Specification Section Page 1 of 9 PART 2 GENERAL 2.01 DESCRIPTION A. Purpose 1. This section covers electrical service meters and sub-meters for use in the Owner's power distribution systems. 2.02 QUALIFICATIONS A. Approved

More information

3 PHASE POWER ANALYZER

3 PHASE POWER ANALYZER SD card real time data recorder with harmonic measurement 3 PHASE POWER ANALYZER Model : DW-6095 Your purchase of this 3 PHASE POWER ANALYZER marks a step forward for you into the field of p r e c i s

More information

Simple Electrical Utility Cost Allocation Solutions

Simple Electrical Utility Cost Allocation Solutions Simple Electrical Utility Cost Allocation Solutions PowerLogic High Density Metering Advanced Submetering and Multi-Tenant Metering Buildings Retail Multi Residential Make the most of your energy. SM Low

More information

User Manual V2.6. SDM120-Modbus. Single-Phase Multifunction DIN rail Meter

User Manual V2.6. SDM120-Modbus. Single-Phase Multifunction DIN rail Meter SDM120-Modbus Single-Phase Multifunction DIN rail Meter Measures kwh, Kvarh, KW, Kvar, KVA, PF, Hz, dmd, V, A, etc. Bi-directional measurement IMP & EXP Two pulse outputs RS485 Modbus Din rail mounting

More information

Modbus Communication for Circuit Breakers

Modbus Communication for Circuit Breakers Modbus Communication for Circuit Breakers Modbus Communication for Circuit Breakers Compact NSX, Compact NS and Masterpact NT/NW Circuit Breakers Quick Start Guide 03/2011 COM-LVP38EN www.schneider-electric.com

More information

UMG 20CM. UMG 20CM 20 Channel Branch Circuit Monitoring Device with RCM. Harmonics via analysis channel RCM. Alarm management.

UMG 20CM. UMG 20CM 20 Channel Branch Circuit Monitoring Device with RCM. Harmonics via analysis channel RCM. Alarm management. RCM Harmonics via analysis channel Alarm management GridVis Analysis software 20 current channels 20 Channel Branch Circuit Monitoring Device with RCM Interfaces / communication RS485 RTU Accuracy of measurement

More information

INTEGRA DIGITAL METERING SYSTEMS

INTEGRA DIGITAL METERING SYSTEMS CROMPTON INSTRUMENTS INTEGRA DIGITAL METERING SYSTEMS INTEGRA DIGITAL METERING SYSTEMS The Integra digital metering product portfolio offers an extensive range of systems designed to suit any power monitoring

More information

Selection & Application Guide. SEM3 - Embedded Micro Metering Module. Scan QR Code for more information.

Selection & Application Guide. SEM3 - Embedded Micro Metering Module. Scan QR Code for more information. Selection & Application Guide SEM3 - Embedded Micro Metering Module Scan QR Code for more information www.usa.siemens.com/sem3 SEM3 - Embedded Micro Metering Module Siemens Embedded Micro Metering Module

More information

Designed For Reliability Manufactured To Last

Designed For Reliability Manufactured To Last 512/1024 samples/cycle IEC 62053-22 Class 0.2S Compliant IEC 61000-4-30 Class A Sag/Swell, Transient and Flicker Comprehensive Data Recording PQDIF & COMTRADE Compatible 5.7 Color LCD Display @ 640x480

More information

POWER PATROL SAVE MONEY - SAVE TIME - SIMPLIFY YOUR JOB. what s inside?

POWER PATROL SAVE MONEY - SAVE TIME - SIMPLIFY YOUR JOB. what s inside? POWER PATROL what s inside? Understanding your Energy Management Needs Why Rogowski Coils? Power Patrol vs. the Competition About the Power Patrol UNDERSTANDING YOUR APPLICATION REQUIREMENTS The first

More information

MultiCube. Modbus Data Tables. August Northern Design (Electronics) Ltd Bradford UK

MultiCube. Modbus Data Tables. August Northern Design (Electronics) Ltd Bradford UK MultiCube Modbus Data Tables August 2005 Modbus Data Tables Northern Design (Electronics) Ltd Bradford UK 1. Introduction This document is intended as a supplement to the MultiCube Modbus Options Installation

More information

with Backlight Graphic LCD Screen

with Backlight Graphic LCD Screen with Backlight Graphic LCD Screen ENERGY AND AUTOMATION POWER OF ENERGY SAVING For the control of energy distribution systems detecting when problems occur that could put the quality and availability of

More information

Si-TEC Xtend GSM DATA SHEET. Digital control range for grid parallel/bus tie. Key features. Description

Si-TEC Xtend GSM DATA SHEET. Digital control range for grid parallel/bus tie. Key features. Description Digital control range for grid parallel/bus tie Si-TEC Xtend GSM DATA SHEET Si-TEC Xtend GSM Master Control is available in 2 variations: 4 GSM Grid Grid Synchronising and Import/Export kw & kvar Control

More information

PM Multifunction meter Cat No. F3N200 - ModbusTable BT EN v1.01.xls

PM Multifunction meter Cat No. F3N200 - ModbusTable BT EN v1.01.xls PM Multifunction meter Cat No. FN200 - ModbusTable BT EN v.0.xls GENERAL MODBUS TABLE ORGANIZATION Starting of the Group s Starting of the Group s System Version (Release) System Version (Build) Group

More information

Leveraging DCIM to Increase Energy Efficiency and Savings

Leveraging DCIM to Increase Energy Efficiency and Savings August 6, 2013 Leveraging DCIM to Increase Energy Efficiency and Savings Siemens AG 2013 All rights reserved. usa.siemens.com/datacenters Contents Challenges of Today s Data Centers Turning Challenges

More information

OPERATING GUIDE endicator intelligent energy monitoring

OPERATING GUIDE endicator intelligent energy monitoring OPERATING GUIDE FOR THE ENDICATOR USER MANUAL, visit www.kele.com/endicator and click on the Related Documents tab. OPERATING GUIDE endicator intelligent energy monitoring The endicator energy monitor

More information

Power and accuracy. Versatile. One display can monitor up to 32 measuring modules information

Power and accuracy. Versatile. One display can monitor up to 32 measuring modules information Power and accuracy 0.2% or 0.5% class in power and active energy measurement Over 500 electric parameters display Both voltage and current harmonics spectrum graphics (to the 50 th ) Maximum and minimum

More information

EM6400 series Multi-Function meters

EM6400 series Multi-Function meters 6400 series Multi-Function meters 1 Digital display & Analog load bar indicators 2 Bright Red LED display 3 Global: CE, UL marks 4 Universal Demand Monitoring Quick and easy installation Turbo Key 6400

More information

Multilin EPM Energy and Demand Submeter with Wi-Fi. Monitoring & Metering. Communications. Key Benefits. Applications

Multilin EPM Energy and Demand Submeter with Wi-Fi. Monitoring & Metering. Communications. Key Benefits. Applications Multilin EPM 6100 Energy and Demand Submeter with Wi-Fi The EPM 6100 is a powerful tool that allows customers to monitor and manage their energy usage within factories, businesses and across campuses.

More information

Innovative monitoring of your data center with DIRIS Digiware

Innovative monitoring of your data center with DIRIS Digiware Innovative monitoring of your data center with DIRIS Digiware Why should you implement power monitoring within your data center? Improving the energy efficiency of your data center allows you to get an

More information

RGM180 Display Series

RGM180 Display Series Quick Start Guide RGM180 Display Series BG0509 REV.A2 RGM180 QUICKSTART LIMITED WARRANTY The manufacturer offers the customer a 24-month functional warranty on the instrument for faulty workmanship or

More information

PowerLogic ION8650 Energy and power quality meter User guide

PowerLogic ION8650 Energy and power quality meter User guide PowerLogic ION8650 Energy and power quality meter User guide 7EN02-0306-01 08/2012 ION8650 User Manual Safety information Safety information Important information Read these instructions carefully and

More information

Series 2400 Paralleling Switchgear

Series 2400 Paralleling Switchgear Series 2400 Paralleling Switchgear SERIES 2400 PARALLELING SWITCHGEAR TYPICAL SERIES 2400 MULTIPLE GENERATOR/UTILITY PARALLELING SWITCHGEAR Intelligent, Configurable Switchgear for Distributed Generation,

More information

Installation and Operation Manual

Installation and Operation Manual Series PM130 PLUS Powermeters PM130P/PM130EH Installation and Operation Manual BG0425 Rev. A1 LIMITED WARRANTY The manufacturer offers the customer a 24-month functional warranty on the instrument for

More information

MODBUS APPLICATION MANUAL DFC-0124

MODBUS APPLICATION MANUAL DFC-0124 MODBUS APPLICATION MANUAL DFC-0124-1 - COPYRIGHT NOTICE Any unauthorized use or copying of the contents or any part of this document is prohibited. This applies in particular to trademarks, model denominations,

More information

DKM-407 DIN RAIL TYPE NETWORK ANALYZER

DKM-407 DIN RAIL TYPE NETWORK ANALYZER DKM-407 User Manual DKM-407 DIN RAIL TYPE NETWORK ANALYZER DESCRIPTION The DKM-407 is a DIN rail mounted precision and low cost unit allowing measurement and remote monitoring of AC parameters of a distribution

More information

FSa0626 Project Notes

FSa0626 Project Notes FSa0626 Project Notes How to test the data 1. From the main menu of ruinet select A for Data Arrays Array Name Array Type Set to zero each time any data in the array is updated. Index Number To look at

More information

PQM - Power Quality Monitoring

PQM - Power Quality Monitoring UMG 96S PQM - Power Quality Monitoring The little field bus giant Universal flush-mounting measuring instruments of the UMG 96S product family are mainly designed for use in low and medium voltage distribution

More information

MID PRELIMINARY DATA SHEET. RI-D Series. Single Phase Multifunction Energy Meter (MID Certified) MID

MID PRELIMINARY DATA SHEET. RI-D Series. Single Phase Multifunction Energy Meter (MID Certified) MID PRELIMINARY DATA SHEET RI-D35-100 Series Single Phase Multifunction Energy Meter (MID Certified) MID direct connected Two pulse outputs LED pulse indication High definition LCD display with white backlight

More information

AcquiSuite Ally 12 & 48 Advanced Multi-Circuit Meter

AcquiSuite Ally 12 & 48 Advanced Multi-Circuit Meter AcquiSuite Ally 12 & 48 Advanced Multi-Circuit Meter Install Guide Revision C (12/18) DANGER HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Revision C (12/18) Turn off all power supplying equipment

More information

Sentron Systems Breaker

Sentron Systems Breaker Sentron Systems Breaker Energy Communicating Trip Unit Information and Instruction Guide System Status Rating Plug I = 1600 A r System Check Tripped Protective Alarm Frame Rating 2000 A Meter ESC Serial

More information

INTELLIGENT ENERGY / POWER METER OPERATING GUIDE VERSION 3 MAY, 2013

INTELLIGENT ENERGY / POWER METER OPERATING GUIDE VERSION 3 MAY, 2013 INTELLIGENT ENERGY / POWER METER OPERATING GUIDE VERSION 3 MAY, 2013 For the EnGenius User Manual, visit www.kele.com/engenius and click on the Related Documents tab. Operating Guide EnGenius Intelling

More information

EOS REMSDAQ CALLISTO NX TYPE E RTU

EOS REMSDAQ CALLISTO NX TYPE E RTU Document Number: EOS 05-9306 Network(s): Summary: ENGINEERING OPERATING STANDARD EOS 05-9306 REMSDAQ CALLISTO NX TYPE E RTU EPN, LPN, SPN This standard details the application, installation and operation

More information

SCC Inc. TS Series. Technical Instructions. Document No. TS-2000 March 15, 2016

SCC Inc. TS Series. Technical Instructions. Document No. TS-2000 March 15, 2016 SCC Inc. TS-MS Master Lead/Lag Panels for Boiler Management, and Building Management System Interface Technical Instructions March 15, 2016 Description A TS-MS Series Master Lead/Lag Panel sequences and

More information

Smart Energy & Power Quality Solutions. UMG 96S Universal flush-mounting measuring instrument

Smart Energy & Power Quality Solutions. UMG 96S Universal flush-mounting measuring instrument Smart Energy & Power Quality Solutions UMG 96S Universal flush-mounting measuring instrument UMG 96S UMG 96S Universal flushmounting measuring instrument Universal flush-mounting measuring instruments

More information

EM133 Multifunction Meter

EM133 Multifunction Meter EM133 Multifunction Meter Modbus Communications Protocol Reference Guide BG0493 Rev. A6 Every effort has been made to ensure that the material herein is complete and accurate. However, the manufacturer

More information

Clink II Integrated Motor Control System

Clink II Integrated Motor Control System link II Integrated Motor ontrol ystem Product ocus Optimising plant performance, efficiency and productivity implex and redundant configuration possible lexibility of communication protocols to higher

More information

SACE Emax 2 Specification guide

SACE Emax 2 Specification guide SACE Emax 2 Specification guide Specification Number: 26 01 20.17 Product Name: LOW VOLTAGE POWER CIRCUIT BREAKERS PART 1 GENERAL NOTE: ( ) Indicates option or a selection is to be made for quantity or

More information

EM133-R Residential Multifunction Meter

EM133-R Residential Multifunction Meter EM133- esidential Multifunction Meter Modbus Communications Protocol eference Guide BG0520 ev. A4 Every effort has been made to ensure that the material herein is complete and accurate. However, the manufacturer

More information

DIRIS Digiware Power metering and monitoring system for AC and DC electrical installations

DIRIS Digiware Power metering and monitoring system for AC and DC electrical installations DIRIS Digiware Power metering and monitoring system for AC and DC electrical installations DIRIS Digiware Power monitoring, accessible everywhere, for everyone The DIRIS Digiware system is a hub of technological

More information