1 TM Rectangular Flat Pack Unique Coded Installation Instructions Certifications IMPORTANT: SAVE THESE INSTRUCTIONS FOR FUTURE USE
2 2 TM Installation Instructions ENGLISH: This instruction sheet is available in multiple languages at Select publication language and type "" in the search field. GERMAN: Dieses Instruktionsblatt kann in mehreren Sprachen unter gelesen werden. Bitte Ihre Sprache anwählen und "" im Suchfeld eintippen. FRENCH: Ces instructions sont disponibles dans différentes langues à l'adresse suivante Sélectionner la langue puis taper dans le champ de recherche. ITALIAN: La presente scheda d'istruzione è disponibile in varie lingue sul sito Selezionare la lingua desiderata e digitare "" nel campo di ricerca. SPANISH: Puede encontrar esta hoja de instrucciones en varios idiomas en Seleccione el idioma de publicación y escriba "" en el campo de búsqueda. PORTUGUESE: Esta folha de instruções está disponível em várias línguas em Seleccione a língua de publicação e entre com "" no espaço de busca. POLISH: Ta kartka z instrukcjami jest dostepna w wielu jezykach na stronie: Wybierz jezyk publikacji i wpisz w polu poszukiwania "". Table of Contents Installation Instructions 3 Warnings 3 Technical Specification 3 Operating Characteristics 3 Outputs (internally fused) 3 Environmental 3 Protection 4 Dimensions 4 Mode of Operation 4 Status Indicators 4 Mounting Information 4 Nut Torque Specification 4 Minimum Distance Between Sensors 5 Misalignment Curve 5 Wiring Diagram 5 Recommended Mating Cable 5 Diagnostics 5 Troubleshooting 6 Application Wiring Examples 8 List of Recommended Relays 12 Maintenance 12 Repair 12 Declaration of Conformity 12
3 Installation Instructions TM Installation Instructions 3 Installation must be in accordance with the following steps and stated specifications and should be carried out by suitable competent personnel. The unit is not to be used as a mechanical stop. Guard stops and guides must be fitted. Adherence to the recommended maintenance instructions forms part of the warranty. This device is intended to be part of the safety related control system of a machine. Before installation, a risk assessment should be performed to determine whether the specifications of this device are suitable for all foreseeable operational and environmental characteristics of the machine to which it is to be fitted. Refer to Technical Specifications for Certification information and ratings. ATTENTION: WARNING: The presence of spare actuators compromise the integrity of the safety systems. Personal injury or death, property damage or economic loss can result. Appropriate management controls, working procedures and alternative protective measures should be introduced to control their use and availability. Do not defeat, tamper, remove or bypass this unit. Severe injury to personnel could result. Technical Specification Safety Ratings CAT4/SIL3 Safety Certifications TÜV, CE Safety Standards IEC , IEC61508, EN954 Certifications culus Standards UL 508 PFHd Operating Characteristics Sensing Distance, Assured Make (mm) 15 Typical misalignment See misalignment curve Maximum output current (all outputs, ma) 200 Input Current 50 ma (no load supply current) Operational Current, Min. 1 ma DC Off-state Current < 0.5 ma DC Maximum # of switches, connected in series Unlimited. See unit response time section Operating Voltage 24V DC +10% / -15% Class 2 SELV power supply Frequency of operating cycle 1 Hz Response Time (Off) 54 ms Case Material Valox DR 48 Actuator Material Valox DR 48 Outputs (Guard door closed, Actuator in place) Outputs Description Status Safety 2 x PNP, 0.2 A max. ON (+24vdc) Auxiliary 1 x PNP, 0.2 A max. OFF (0vdc) Environmental Operating Temperature C ( F) Operating Humidity 5% -95% relative Washdown rating NEMA 3, 4X, 12,13, IP 69K Shock & Vibration IEC g, 11 ms/iec Hz Radio Frequency IEC IEC
4 4 TM Installation Instructions Protection Short-Circuit Protection Incorporated Current limitation Incorporated Overload Protection Incorporated False Pulse Protection Incorporated Transient Noise Protection Incorporated Reverse Polarity Protection Incorporated Overvoltage protection Incorporated Thermal shutdown/restart Incorporated Electrical Life 10 x 10 6 Dimensions - mm (inches) (0.73) (0.984) (0.813) (0.73) (0.984) (0.813) 4.57 (0.18) (0.42) (3.47) (2.689) (3.07) (3.47) (2.282) (3.25) 72.9 (2.87) (2.462) (3.07) (0.42) 7.11 (0.28) 5.08 ( 0.2)) 4.57 (0.18) 5.08 ( 0.2) 4.57 (0.18) 6.78 (0.267) 4.57 (0.18) 4.57 (0.18) (0.528) 9.96 (0.392) QD CONNECTOR VERSION M12 x ( 0.38) Mode of Operation Status indicators: Status/Diag LED illuminates Green - Door/Guard closed, safety outputs active. Status/Diag LED illuminates : - Door/Guard open, safety outputs off. Status/Diag LED flashes or Green: - Unit failure. See Diagnostic section below. Status/Diag LED flashes Amber when Sensor is approaching max. sensing distance. Mounting Information Use non-removable screws, bolts, or nuts to mount the switch and actuator. Do not over torque the mounting hardware. Position the switch and actuator so they are aligned with each other. Mount the switch and actuator to removable guard, door or gate. Keep the switch and actuator within the sensing range shown in the sensing/misalignment curve. Nut Torque Specification Switch/Actuator: 2.26 N M (20 in lbs) Minimum Distance Between Sensors mm mm
5 Sensing/Misalignment Curve TM Installation Instructions 5 Sensinng Distance (mm) Misalignment (mm) Note: There must be a minimum spacing of 9mm (0.35 ) if the actuator and sensor face approaches laterally.this will prevent false triggering due to the side lobes areas. Typical Wiring Diagram Description Plastic 8-Pin Micro (M12) 3-N/A 8-Safety A+ 4-Safety B+ 5-Safety A Grey Safety A Safety A+ Safety B 8-Pin Cordset Safety B+ 889D-F8AB-* White Aux A or cable version 24V DC+ Gnd Green N/A * Replace symbol with 2 (2m), 5 (5m) or 10 (10m) for standard cable lengths. Diagnostic 2-24V DC+ 1-Aux A 7-Gnd 6-Safety B Unit Indicators (per IEC 60073) State Status Troubleshooting Off Not Powered NA Status/Diag Not Safe, OSSD not active NA LED Green Safe, OSSD active NA Green flash Power up test or OSSD Check 24V DC or OSSD inputs inputs not valid (yellow and red wire) Flash 1 Hz Flash Recoverable Fault Recoverable fault check OSSD 4 Hz Flash Non-recoverable Fault outputs are not shorted to, 24V DC or each other. Cycle power. Amber 1 Hz Flash margin indicator Sensor is reaching max. sensing Flash safe, OSSD active distance; re-align sensor with actuator
6 6 TM Installation Instructions Commissioning Power the Sensor Connect the sensor to 24Vdc. See "Typical Wiring Diagram" section for help. Note: The sensor "Status/Diag" LED will begin to blink Green eight times then repeat, indicating that the sensor has not yet learned an actuator. The sensor can be commissioned to either have the ability to learn another actuator or be locked for a one time learn only. See Teaching in the actuator section. Teaching in the actuator (Ability to learn an additional actuator) Note: The sensor can learn a new actuator up to eight times. The "Status/Diag" LED will blink the number of actuators left that an sensor can learn. Initially teaching in the actuator The sensor will automatically start the learning process as soon as an actuator is brought into the sensing range. Important! The actuator must not be removed from the sensing field during the learning procedure or the ability to learn additional actuator will be disabled. Learning Sequence 1.Target present: "Status/Diag" LED blinking Green 1Hz rate 2. Verifying actuator: "Status/Diag" LED blinking Green/RED 1Hz rate (15sec) 3. Program Sensor: "Status/Diag" LED blinking Green/RED 4Hz rate (15sec) 4. Program Complete: "Status/Diag" LED blinking Green (# of learns left) (15 sec) 5. Ready state: "Status/Diag" LED solid Green 6. Learn is complete Note: A sensor can be locked so it can not learn another actuator; see teaching in the actuator (one time learn only) section. Teaching in the actuator (One time learn only; Unit locked) Initially teaching in the actuator The sensor will automatically start the learning process as soon as an actuator is brought into the sensing range. Learning Sequence 1. Target present: "Status/Diag" LED blinking Green 1Hz rate 2. Verifying actuator: "Status/Diag" LED blinking Green/RED 1Hz rate (15sec) 3. Program Sensor: "Status/Diag" LED blinking Green/RED 4Hz rate (15sec) 4. Program Locking: "Status/Diag" LED blinking Green (# of learn left) (15 sec)
7 TM Installation Instructions 7 During the Program Locking Stage, perform the following steps: a. Remove the actuator from the sensing field, until the "Status/Diag" LED changes to solid. b. Replace the actuator back into the sensing field and the "Status/Diag" LED will continue blinking Green (# of learns left). Note: The program locking sequence must be completed within the 15 second program locking window. 5. Ready state: "Status/Diag" LED solid Green 6. Learn is complete Learning a new actuator: To learn a replacement actuator; bring the actuator to be taught into the sensing range of the safety switch. The learn sequence is same as the sequence for commissioning the first actuator. Note: A sensor can be locked so it can not learn another actuator by removing the actuator from the sensing field during the 15 sec "Program Complete" sequence. A sensor can not re-learn a previously learned actuator or a standard actuator. Unique Coded Diagnostic: Error codes for learning process - Repeat until unit is power cycled Status/Diag LED - Flashes (4Hz) Green ---Green ---Green-Green ---Green-Green-Green ---Green-Green-Green-Green ---Green-Green-Green-Green-Green Error Code OSSD inputs not valid Can not learn a standard Actuator Actuator already learned Bad RFID; Target moved out of range Exceeded learning 8 actuators Unit locked: Can not learn another actuator
8 8 TM Installation Instructions Magnetic Holding Force Graph FORCE (N) Distance (mm) The magnetic force is measured from the face of actuator to the face of the sensor.
9 TM Installation Instructions 9 Troubleshooting Series Circuit Actuator 5 Switch 5 White +0 V +0 V Yel +0 V +0 V Actuator 5 is in sensing range. Switch 5 is functioning properly. Series inputs are 0V. OSSDs are de-energized to 0V. Green LED is Flashing to indicate Series inputs are not 24V. Actuator 4 Switch 4 White Yel Yel 24VDC Power Supply XL120D Actuator 4 is in sensing range. Switch 4 is functioning properly. Switch 1 RTN Series inputs are 0 V. OSSDs are de-energized to 0V. Green LED is Flashing to indicate Series inputs are not 24V. +24 Actuator 3 Switch 3 White +0 V +0 V Yel +24 V +24 V Actuator 3 is in sensing range. Switch 3 has fault. See Table Above LED is flashing Actuator 1 Actuator 2 Switch 2 White Yel +24 V +24 V White Recoverable fault OSSD s are OFF Actuator 2 is in sensing range. Switch 2 is functioning properly OSSDs are energize to 24 V Green LED is ON. Actuator 1 is in sensing range. Switch 1 is functioning properly OSSDs are energize to 24 V Green LED is ON.
10 10 TM Installation Instructions Unit Response Time (does not include safety relay response time) White Yel Sensor 1 Sensor 2 24V DC Power Supply RT Yel White White Yel A1 S11 S52 S R-N23126 S21 S22 S34 A Actuator 1 Actuator 2 Actuator 3 Sensor 3 OFF ON Initial Conditions: All actuators are in sensing distance. Actuator 1 is out of sensing range. Actuator 2 and 3 are in sensing range. Actuator 1 is moved out of sensing range. Sensor 2 drops the 24 volts (red and yellow) from Sensor 1 OSSD outputs. Green LED flashes. Sensor 3 drops the 24 volts (red and yellow) from Sensor 2 OSSD outputs. Green LED flashes. 0 ms 54 ms 72 ms 90 ms Actuator 1 is moved into sensing range. Sensor 1 OSSD outputs are energized. Sensor 2 OSSD inputs (red and yellow) transition to 24V DC from Sensor 1 OSSD outputs. Sensor 2 OSSD outputs are energized Sensor 3 OSSD inputs (red and yellow) transition to 24V DC from Sensor 2 OSSD outputs. Sensor 3 OSSD outputs are energized. 0 ms 360 ms 378 ms 396 ms
11 Application Wiring Examples TM Installation Instructions 11 Unit 3 Unit 2 Unit 1 Reset A1 S11 S52 S MSR127RP S21 S22 S34 A MSR127RP with 3 sensors in series, monitored manual reset, driving 100S or 700S safety controllers A1 S11 S52 S MSR127TP S21 S22 S34 A Unit 1 Reset A1 S11 S52 S MSR127RP S21 S22 S34 A MSR127RP with 1 sensor, monitored manual reset, driving 100S or 700S safety controllers. MSR127RP with 1 sensor, automatic reset, driving 100S or 700S safety controllers Unit 1 GuardShield Unit 3 Unit 2 Unit 1 Reset A1 S11 S52 S MSR127RP S21 S22 S34 A MSR127RP with 3 sensors and 1 440L light curtain in series, monitored manual reset, driving 100S or 700S safety relays. Note: Light curtain must be last (farthest from MSR127).
12 12 TM Installation Instructions Application Wiring Examples GuardShield Unit 3 Unit 2 Unit 1 A1 S11 S52 S MSR127TP S21 S22 S34 A Unit 3 Unit 2 Unit 1 MSR127TP with 3 sensors and 1 440L light curtain in series, automatic reset, driving 100S or 700S safety contactors. Note: Light curtain must be last (farthest from MSR127) A1 S11 S52 S MSR127TP S21 S22 S34 A MSR127TP with 3 sensors in series, automatic reset, driving 100S or 700S relays.
13 Application Wiring Examples TM Installation Instructions 13 S12 S42 K3 S12 S42 K3 S20 S50 K4 S20 S50 K4 S62 S62 GuardShield S12 S20 S51 Y40 Y41 S12 S20 S11 S21 S31 S Y42 A1 440R-H R-H R-H23177 MSR221P MSR211P MSR230P S42 S50 S62 S42 S50 S62 S34 Y1 Y2 Y Y32 Y33 Y30 A2 MSR200 series with 3 sensors and 1 440L light curtain, automatic reset, driving 100S or 700S safety contactors. Note: Light curtain can be attached to any input GuardShield S12 S20 S51 Y40 Y41 S12 S20 S11 S21 S31 S Y42 A1 440R-H R-H R-H23177 MSR221P MSR211P MSR230P S42 S50 S62 S42 S50 S62 S34 Y1 Y2 Y Y32 Y33 Y30 A2 Reset MSR200 series with 3 sensors and 1 440L light curtain, manual reset, driving 100S or 700S safety contactors. Note: Light curtain can be attached to any input.
14 14 TM Installation Instructions Application Wiring Examples S12 S42 K3 S12 S42 K3 S20 S50 K4 S20 S50 K4 S62 S62 S12 S20 S51 Y40 Y41 S12 S20 S11 S21 S31 S Y42 A1 440R-H R-H R-H23177 MSR221P MSR211P MSR230P S42 S50 S62 S42 S50 S62 S34 Y1 Y2 Y Y32 Y33 Y30 A2 MSR200 series with 4 sensors, automatic reset, driving 100S or 700S safety contactors. S12 S20 S51 Y40 Y41 S12 S20 S11 S21 S31 S Y42 A1 440R-H R-H R-H23177 MSR221P MSR211P MSR230P S42 S50 S62 S42 S50 S62 S34 Y1 Y2 Y Y32 Y33 Y30 A2 Reset MSR200 series with 4 sensors, manual reset, driving 100S or 700S safety contactors.
15 List of recommended relays TM Installation Instructions 15 MSR126, MSR127, MSR123, MSR124, MSR131, MSR138, MSR211, MSR121, MSR200 Family (Except MSR210), MSR300 Family, SmartGuard, 1791 DS DeviceNet Safety I/O. Relay must have light curtain inputs. Check the machine is isolated and stopped whenever the interlocked guard door is open. IMPORTANT: After installation and commissioning, the actuator, switch and switch lid fixing screws should be coated with tamper evident varnish or similar compound. Maintenance Every week. Check the correct operation of the switching circuit. Also check for signs of abuse or tampering. Inspect the switch casing for damage Repair If there is any malfunction or damage, no attempts at repair should be made. The unit should be replaced before machine operation is allowed. Declaration of Conformity This is to declare that the products shown on this document conforms with the Essential Health and Safety Requirements (EHSR s) of the European Machinery Directive (73/23/EEC as amended by 93/68/EEC). These products also conform to EN , EN 1088, EN292, EN and have Third Party Approval. For a comprehensive certificate please visit:
16 2 TM Installation Instructions R
Magnetically Coded Non Contact Switch (MC2) Installation Instructions
Magnetically Coded Non Contact Switch (MC2) Installation Instructions 44N-Z21W1PA 44N-Z21W1PB 44N-Z21W1PH 3 Metre Cable 1 Metre Cable 8-Pin micro (M) Pigtail Certifications IMPORTANT: SAVE THESE INSTRUCTIONS
More informationSpecifications. Functional Safety Data Note: For up-to-date information, visit Certifications.
Safety Non-Contact General 1-2-Opto-electronics 3-Interlock Logic Description When it comes to machine safety, Rockwell Automation knows that protection of personnel and equipment is your main concern.
More informationSensaGuard 18 mm Barrels
Installation Instructions Original Instructions SensaGuard 18 mm Barrels Catalog Numbers Low-Level Coding: 440N-Z1S16A, 440N-Z1S16B, 440N-Z1S16H, 440N-Z1S16J, 440N-Z1S17A, 440N-Z1S17B, 440N-Z1S17H, 440N-Z1S6A,
More informationSensaGuard. Description. Features. Benefits. Specifications
SensaGuard Description When it comes to machine safety, Rockwell Automation knows that protection of personnel and equipment is your main concern. At the same time, flexibility and productivity are points
More information3-56. General 1-2-Opto-electronics 3-Interlock. Switches. Operator. Interface. Logic Power. Safety Switches Non-Contact Switches SensaGuard
Safety General 1-2-Opto-electronics 3-Interlock Logic Description When it comes to machine safety, ockwell Automation knows that protection of personnel and equipment is your main concern. At the same
More informationTLSZR/L-GD2 Guard Locking Switch Installation Instructions
Guard Locking Switch Installation Instructions IMPORTANT IMPORTANT WICHTIG IMPORTANTE IMPORTANTE IMPORTANTE Do not attempt to install this device unless the installation instructions have been studied
More informationNHP SAFETY REFERENCE GUIDE
NHP SAFETY REFERENCE GUIDE GSR SAFETY FUNCTION DOCUMENTS SensaGuard Non-contact Interlock Switch with E-stop Table of Contents: Important User Information 45 General Safety Information 45 Introduction
More informationTongue Switches Visit our website: Interlock. Switches. Safety Switches. Trojan 5 & 6. Specifications.
1-2 -Interlock Safety 4 Description The Trojan family is a universal tongue-operated (or key-operated) safety-interlock switch designed to fit at the leading edge of sliding, hinged or lift-off guards.
More informationOriginal operating instructions Fail-safe inductive sensor GF711S / / 2013
Original operating instructions Fail-safe inductive sensor GF7S 8528 / 5 / 23 Contents Preliminary note...3. Explanation of symbols...3 2 Safety instructions...4 2. Safety-related requirements regarding
More informationMSR178DP. Description. Features. Specifications
MSR178DP Description The MSR178DP is a multi-function time-delay relay for use in safety circuits. It can be configured by the user to perform on-delay, offdelay or single-pulse modes. It is used for applications
More informationSafeC S to MSR127 Conversion
Application Note SafeC S to MSR127 Conversion IMPORTANT: A risk assessment must be completed to assure that all tasks and hazards are considered and confirm that the example circuit will provide adequate
More informationOriginal operating instructions Fail-safe inductive sensor GI711S / / 2010
Original operating instructions Fail-safe inductive sensor GI7S 704583 / 0 06 / 200 Contents Preliminary note 3. Explanation of symbols 3 2 Safety instructions 4 2. Safety-related requirements regarding
More informationLifeline 5 Cable-pull Safety Switch
Installation Instructions Original Instructions Cable-pull Safety Switch Catalog Numbers 440E-LL5SS8, 440E-LL5SS5, 440E-LL5SE8, 440E-LL5SE5, 440E-LL5SN8, 440E-LL5SN5 Topic Additional Resources 1 Introduction
More informationMagnetically Actuated Safety Interlock Switches
Rev. 7.07 C US Conforms to EN1088, EN292, EN6020-1 CSA approved MA Series Magnetically Actuated Safety Interlock es Large selection choose from a large selection of contact configurations housed in plastic
More informationBul. 440R Guardmaster Safety Relays (DI, DIS, SI, CI, EM, and EMD) Selection Guide
Bul. 440R Guardmaster Safety Relays (DI, DIS, SI, CI, EM, and EMD) Selection Guide Description The new generation of Guardmaster Safety Relays addresses the broad scope of applications in the intricate
More informationNon-contact Machine Safeguarding with RFID Technology. LED offers diagnostics for switch status, margin alignment, and fault finding
Interlock SensaGuard Non-Contact 440N RFID unique (high) or standard (low) coded actuators PLe Cat 4 per ISO 3849- (safety performance is maintained when connected in series) Flat pack and barrel (plastic
More informationSafety Contacts: AC models MA-1 thru 5, 10, 12, 13, 16 1 N/C MA-13, 16, 21 2 N/C DC models MA-12, 13, 14, 16 1 N/C MA-13, 15, 16, 20, 21 2 N/C
r Safety Interlock Switches MA Series MA Magnetically Actuated Safety Interlock Switches Large selection choose from a large selection of contact configurations housed in plastic to satisfy most application
More informationFor full product information, visit Use the SpeedSpec code or scan the QR Code for quick access to the specific web page.
R Safety Interlock Switches MA Series MA For full product information, visit www.sti.com. Use the SpeedSpec code or scan the QR Code for quick access to the specific web page. Magnetically Actuated Safety
More informationOriginal operating instructions Fail-safe inductive sensor GI712S
Original operating instructions Fail-safe inductive sensor GI712S 80236527 / 00 12 / 2016 Contents 1 Preliminary note...3 1.1 Symbols used...3 1.2 Warning signs used...3 2 Safety instructions...4 2.1 Safety-related
More informationThe SMART Non-contact Safety Sensor SRF With an innovative diagnostic system
The SMART With an innovative diagnostic system Actual size shown Very compact: small in size, flexible in use Very Smart: suitable for Industry 4.0 with its intelligent diagnostic system Cost Saving: four-wire
More informationOriginal operating instructions Fail-safe inductive sensor GG711S
Original operating instructions Fail-safe inductive sensor GG7S 8236522 / 2 / 26 Contents Preliminary note...3. Symbols used...3.2 Warning signs used...3 2 Safety instructions...4 2. Safety-related requirements
More informationMSR42 Micro 400 Controller/Muting Module
MSR42 Micro 400 Controller/Muting Module Description The MSR42 multi-function safety relay is the control module for the GuardShield Micro 400 safety light curtain, but can also be used with any light
More informationSALES NUMBER NUMBER OF BEAMS PROTECTIVE HEIGHT
SECTION 21 182 Safety Light Curtains Type: SLC-F Finger (14mm) FEATURES: Resolution: 14mm Protective height: 160mm to 1040mm Type 4 according to IEC61496-1 and -2 ORDERING INFORMATION: SALES OF BEAMS PROTECTIVE
More informationOperating instructions AS-i SmartLine module AC3200 AC /00 06/2016
Operating instructions AS-i SmartLine module AC3200 AC3201 80237876/00 06/2016 Contents 1 Preliminary note...3 1.1 Symbols used...3 1.2 Warnings used...3 2 Safety instructions...3 2.1 General...3 2.2 Target
More informationMagnetically Actuated Safety Interlock Switches
Conforms to EN10, EN292, EN020-1 CSA and BG approved Actual Size Magnetically Actuated Safety Interlock Switches Large selection choose from a large selection of contact configurations housed in plastic,
More informationSafety Light Curtains GuardShield Remote Teach
Specifications Presence Sensing Safety Devices Description The system provides a remote means of changing a fixed blanking configuration within the GuardShield safety light curtain. This keyswitch box
More informationOriginal operating instructions Safety relay with relay outputs with and without delay G1502S / / 2016
Original operating instructions Safety relay with relay outputs with and without delay UK G50S 803638 / 00 0 / 06 Contents Preliminary note...4. Symbols used...4 Safety instructions...5 3 Items supplied...6
More informationUsing GuardShield Light Curtains (Safe 4, Micro 400, or 440L), with ArmorBlock Guard I/O and SmartGuard Controller
Safety Application Example Using GuardShield Light Curtains (Safe 4, Micro 400, or 440L), with ArmorBlock Guard I/O and SmartGuard Controller Light Curtain with On-machine Components Safety Rating: Category
More informationTLSZR/L-GD2 Guard Locking Switch
Installation Instructions Original Instructions TLSZR/L-GD Guard Locking Switch Catalog Numbers 440G-TZS1UPRH, 440G-TZS1UPLH, 440G-TZS1UTRH, 440G-TZS1UTLH WICHTIG E Do not attempt to install this device
More informationOriginal operating instructions Safety relay with relay outputs G1501S / / 2016
Original operating instructions Safety relay with relay outputs G50S UK 8023637 / 00 02 / 206 Contents Preliminary note...4. Symbols used...4 2 Safety instructions...5 3 Items supplied...6 4 Functions
More informationCompactBlock Guard I/O Modules ArmorBlock Guard I/O Modules POINT Guard I/O Modules
Overview Overview Control and monitor your safety devices with Guard I/O. When used with Rockwell Automation safety controllers, Guard I/O communicates on EtherNet/IP or DeviceNet using CIP Safety protocol.
More informationFSO Webnair FSO Safety Functions Module. ABB Group February 11, 2015 Slide 1
FSO Webnair FSO Safety Functions Module February 11, 2015 Slide 1 Competence Requirements for ABB Commissioner / Service Engineer of ACS880 Drives with FSO The integrated Safety Function Module (FSO; option
More informationCopyright 2011 Rockwell Automation, Inc. All rights reserved. Next Generation Guardmaster Safety Relay Platform Overview
Next Generation Guardmaster Safety Relay Platform Overview RA Safety Relays MSR Minotaur Safety Relay MSR6 Rockwell Automation s first electromechanical safety relay series MSR100 2nd generation of electromechanical
More informationXCSRC10M12 Safety RFID contactless switch - Single model - Unique pairing
Product data sheet Characteristics XCSRC10M12 Safety RFID contactless switch - Single model - Unique pairing Main Range of product Product or component type Component name Preventa Safety detection Preventa
More informationSpecifications. Description. Degree of Protection. Input Voltage (Relay type) Input Voltage (Solid-State type) Electrical Design Life (Relay type)
General Principles 9-10-Safety Logic Power General Purpose 800Z-GF2Q5 Heavy Industrial 800Z-HF1 General Purpose 800Z-GL3Q5B Heavy Industrial 800Z-HL1Y Bulletin 800Z Zero-Force are designed for use by machine
More informationGuardmaster 440G-LZ Guard Locking Switch User Manual
Guardmaster 440G-LZ Guard Locking Switch User Manual Important User Information Solid-state equipment has operational characteristics differing from those of electromechanical equipment. Safety Guidelines
More informationOperating instructions. Speed monitor D / / 2014
Operating instructions Speed monitor D200 80005257 / 00 05 / 2014 Contents 1 Preliminary note...4 1.1 Symbols used...4 1.2 Warning signs used...4 2 Safety instructions...5 2.1 General...5 2.2 Target group...5
More informationMaking Hazardous Operations Safe and Productive
NEW Safety Guard Switching Unit G9SX-GS Making Hazardous Operations Safe and Productive Making Hazardous Operations Safe and Productive This new addition to the model of Flexible Safety Unit G9SX series
More informationOperating instructions. Switching amplifier DN0210 DN / / 2015
Operating instructions Switching amplifier DN0210 DN0220 UK 80011079 / 00 01 / 2015 Contents 1 Preliminary note...4 1.1 Symbols used...4 1.2 Warning signs used...4 2 Safety instructions...5 2.1 General...5
More informationFor full product information, visit Use the SpeedSpec code or scan the QR Code for quick access to the specific web page.
R Safety Monitoring Relays For full product information, visit www.sti.com. Use the SpeedSpec code or scan the QR Code for quick access to the specific web page. Dual-Channel Safety Monitoring Relay Power
More informationD6030S - D6030D INSTRUCTION MANUAL. D SIL 3 Switch/Proximity Detector Repeater Relay Output. Models D6030S, D6030D
D600S - D600D INSTRUCTI MANUAL SIL Switch/Proximity Detector Repeater Relay, DIN Rail, Models D600S, D600D D600 - SIL Switch/Proximity Detector Repeater Relay G.M. International ISM0- Characteristics General
More informationApplication Technique. Safety Function: Safety Camera with E-stop
Application Technique Safety Function: Safety Camera with E-stop Products: Guardmaster Dual-input Safety Relay, Guardmaster SC300 Safety Camera Safety Rating: PLd, Cat. 3 to EN ISO 13849-1: 2008 2 Safety
More informationFACTORY AUTOMATION. MANUAL VAA-2E-G4-SE Original Instructions Version 1.1
FACTORY AUTOMATION MANUAL VAA-2E-G4-SE Original Instructions Version 1.1 With regard to the supply of products, the current issue of the following document is applicable: The General Terms of Delivery
More informationPresence Sensing Safety Devices
Presence Sensing Devices GuardShield POC Type 4 440L Point of Operation Control (POC) for finger or hand protection Heavy-duty IP65 housing Large operating range 0.3 6 m (0.98 52.49 ft) Dip switch selectable
More informationSafety. Detection. Control. MAGNUS RFID ENG - REV
03 2017 1 Next generation RFID safety sensor 03 2017 2 03 2017 3 Next generation sensors for machine safety RFID safety sensors PL e, SIL 3 The application of Magnus RFID sensors can be extremely wide
More informationSECTION 16 LED DIAGNOSTIC FEATURES: EXPANSION UNITS: SCR-31P-i. SCR-73-i. SEU-31-i. SCR-31-42TD-i. SEU-31TD-i
SECTION 16 VIPER Safety Relays Type: SCR-i (with added diagnostics) SAFETY RELAY FUNCTION: IDEM s VIPER SCR-i range of Safety Relays have been designed in accordance with EN60204-1 for safety circuits
More informationCM Series. Most Diverse and Flexible Line of Coded Magnetic Safety Interlock Switches and Controllers. Description. Safety Interlock Switches
R Safety Interlock Switches CM Series CM For full product information, visit www.sti.com. Use the SpeedSPEC Code for quick access to the specific web page. Most Diverse and Flexible Line of Coded Magnetic
More informationCompact Coded Magnetic Safety Interlock Switch and Control Units
C Conforms to EN292, EN60204-1, EN954-1, EN1088, EN60947-5-3, EN947-5-3, EN50081, EN50082, EN61000-6-2 UL and C-UL listed, TUV certified Description R US Compact Coded Magnetic Safety Interlock Switch
More informationCompact Magnetic Non-contact Safety Switches. Model Number Structure
Compact Non-contact Safety Switches Coded Non-contact switches are designed to interlock hinge, sliding or removal guard doors. All coded Non-contact switches have a LED for easy diagnosis. Coded actuator
More informationNot recommended for use in applications where there is high probability for exposure to liquid (e.g., cutting fluid) on the sensing surface area.
Bulletin Z Product Overview Bulletin Z Bulletin Z Zero-Force Touch Buttons are ideally suited for use in two-hand machine control systems and highly repetitive applications. Ergonomic Design The contour
More informationDescription. Features. Ultrasonic Sensors 873P Analog or Discrete Output INTRODUCTION. 873P Analog Output18 mm. 873P Discrete Output30 mm
INTRODUCTION 873P Analog Output18 mm 873P Discrete Output30 mm Description Bulletin 873P Ultrasonic Sensors are self contained solid state devices designed for noncontact sensing of solid and liquid objects.
More informationUser's Manual. english
BES M12EN-PFC40F-S04G-D11 BES M18EN-PFC80F-S04G-D11 BES M18MN-PFC50B-S04G-D11 BES M30EN-PFC15F-S04G-D11 BES M30MN-PFC10B-S04G-D11 Inductive Safety Sensors User's Manual english www.balluff.com Original
More informationXUSL4E14F046N XUSL type 4 - Finger protection - Std sensing range - Hp = 460 mm, R=14mm
Characteristics XUSL type 4 - Finger protection - Std sensing range - Hp = 460 mm, R=14mm Main Range of product Nov 18, 2017 Preventa Safety detection Product or component type Safety light curtain type
More informationVersatile Safety Interlock Switch with Guard Door Locking
R Conforms to EN1088, EN60947-5-1, EN292, EN60204-1 UL and C-UL listed, BG approved Versatile Safety Interlock Switch with Guard Door Locking High locking force of 450 pounds locks guard door shut until
More informationXPSMCMMX inputs 2 output pairs expansion module with screw term
Characteristics 8 inputs 2 output pairs expansion module with screw term Main Range of product Product or component type Device short name Electrical connection [Us] rated supply voltage Number of inputs
More informationPSR-MS60. Safety relay for emergency stop, safety door and light grid monitoring. Data sheet. 1 Description
SILCL IEC 62061 Safety relay for emergency stop, safety door and light grid monitoring Data sheet 106171_en_01 PHOENIX CONTACT 2015-05-19 1 Description Intended Use The PSR-MS60 safety relay can be used
More informationEH-RIO IP67 Profibus-DP I/O modules
Installation Instructions EH-RIO IP67 Profibus-DP I/O modules (RIO-PBXDP8M12, -PBXDP8M8, -PBYTP8M12, -PBYTP8M8, -PBXYP8M12, -PBXYP8M8) M12 Style Connectors M8 Style Connectors 43819 The EH-RIO IP67 Profibus-DP
More informationINSTRUCTION MANUAL. SIL 3 Switch/Proximity Detector Repeater Relay Output, Termination Board Models D6032S, D6032D
D603S D603D INSTRUCTI MANUAL SIL 3 Switch/Proximity Detector Repeater Relay, Termination Board Models D603S, D603D D603 SIL 3 Switch/Proximity Detector Repeater Relay G.M. International ISM0400 General
More informationApplication Technique. Safety Function: SensaGuard Non-contact Interlock Switch
Application Technique Safety Function: SensaGuard Non-contact Interlock Switch Products: SensaGuard Switch, GuardLogix Controller Safety Rating: CAT. 4, PLe to EN ISO 13849-1: 2008 2 Safety Function: SensaGuard
More informationOnline data sheet. TR4-SDM03P TR4 Direct NON-CONTACT SAFETY SWITCHES
Online data sheet TR4-SDM03P TR4 Direct A B C D E F H I J K L M N O P Q R S T Detailed technical data Features System part Sensor principle Ordering information Other models and accessories Number of safe
More informationOperating instructions. Standstill monitor A / / 2011
Operating instructions Standstill monitor A300 UK 1 2 3 4 5 6 7 8 7390337 / 01 02 / 2011 1 2 3 4 5 6 7 8 switchpoint min max pulse/min power Made in Germany ifm electronic gmbh D 45127 Essen func. I II
More informationNHP SAFETY REFERENCE GUIDE
NHP SAFETY REFERENCE GUIDE GSR SAFETY FUNCTION DOCUMENTS E-Stop Safety Function Table of Contents: Introduction 6-18 Important User Information 6-18 General Safety Information 6-19 Safety Function Realization
More informationTongue Switches Trojan 5 & 6
Interlock Switches Description The Trojan family is a universal tongue (or key) actuated safety interlock switch designed to fit at the leading edge of sliding, hinged or lift-off guards. The dual key
More informationDeviceNet ArmorBlock Network Powered 16-input Module
Installation Instructions DeviceNet ArmorBlock Network Powered 16-input Module Catalog number 1732D-IBDPM12MND, Series A Table of Contents Topic Page Important User Information 2 Environment and Enclosure
More informationQ45U Ultrasonic Sensors
s Piezoelectric Proximity Mode Sensors with Push button Programming of Sensing Window Limits Features Ultrasonic proximity detection from 100 to 1400 millimeters (4 to 55 inches) Push button TEACH mode
More informationXUSL4E14F121N XUSL type 4 - Finger protection - Std sensing range - Hp = 1210mm, R=14mm
Characteristics XUSL type 4 - Finger protection - Std sensing range - Hp = 1210mm, R=14mm Complementary Detection system Response time Kit composition [EAA] effective aperture angle Emission Main Range
More informationMA Series. Safety, Technology & Innovation. Description. Approvals. Operation. Applications. Declaration of Conformity
, Technology & Innovation MA Series Operating Instructions for MA-11 Switches KEEP THIS GUIDE FOR FUTURE REFERENCE This information is designed to help suitably qualified personnel install and operate
More informationOriginal operating instructions. Fail-safe SmartPLC with Profinet slave interface AC402S /00 06/2016
Original operating instructions Fail-safe SmartPLC with Profinet slave interface AC402S UK 80237419/00 06/2016 Contents 1 Preliminary note...4 1.1 Notes on this document...4 1.2 Symbols used...4 2 Safety
More informationT4HD: Installation Supplement R8.1.13
THD: Installation Supplement R8.. Smartscan Incorporated 08 Eight Mile Road Livonia MI 8 Tel: (8)77-900 Fax: (8) 77-7 Web: www.smartscaninc.com Smartscan Incorporated Livonia, Michigan THD The use of this
More informationSpecifications. Safety Ratings. Standards. Safety Classification. Certifications. Outputs. Safety Contacts. Auxiliary Contacts
Safety TLS- General 1-2-Opto-electronics 3-Interlock Logic Description The TLS- is a positive mode, tongue operated guard locking interlock switch that locks a machine guard closed until power is isolated
More informationSpecifications. Safety Ratings. Standards. Safety Classification. Certifications. Safety Contacts. Locking Type. Power Supply. Operating Radius, Min
TLS- General 1-2-Opto-electronics 3-Interlock Logic Description The TLS- is a positive mode, tongue operated guard locking interlock switch that locks a machine guard closed until power is isolated and
More informationXPSMCMDO Digital output pairs expansion modules with screw term
Characteristics 2 Digital output pairs expansion modules with screw term Main Range of product Product or component type Device short name Electrical connection [Us] rated supply voltage Number of inputs
More informationG9SX-GS. Safety Guard Switching Unit. A Safety Measure for Hazardous Operations That Does Not Lower Productivity. Auto Switching Function
Safety Guard Switching Unit CSM DS_E_6_1 A Safety Measure for Hazardous Operations That Does Not Lower Productivity Two functions support two types of application: Auto switching: For applications where
More informationMuting Applications with the MSR300 Table of Contents
Application Note Muting Applications with the MSR00 Table of Contents ) Purpose... ) References... ) Muting Input Module... ) Muting Sensors... 5) Muting Lamp Module... 6) Reset... 7) Saving the Configuration
More informationBulletin 800Z Zero-Force Touch Buttons
Bulletin 800Z Zero-Force Touch Buttons IEC and NEMA Style General Purpose Range Heavy Industrial Range Protection Class 4/4X/3 and 4/3 IP66 Internationally Rated Ergonomically Designed Touch Buttons Table
More informationGuardmaster Safety Relays DI, DIS, SI, CI, GLP, EM, And EMD
Guardmaster Safety Relays DI, DIS, SI, CI, GLP, EM, And EMD Description The new generation of Guardmaster safety relays addresses the broad scope of applications in the intricate safety world with a range
More informationCompact Magnetic Non-contact Safety Switches. Model Number Structure
Compact Non-contact Safety Switches FS-TGR-N@C Coded Non-contact switches are designed to interlock hinge, sliding or removal guard doors. All coded Non-contact switches have a LED for easy diagnosis.
More informationOperating Instructions
Key Adapter CKS-K-AS2A-U-C20-PC (Unicode) EN Contents 1. About this document... 3 1.1. Scope...3 1.2. Target group...3 1.3. Key to symbols...3 1.4. Supplementary documents...3 2. Correct use... 4 3. Description
More informationSafety Mats & Area Guarding
Safety Mats & Area Guarding MC Controllers MC MC, MC and MC Series Safety Mat Controllers The MC Series safety mat controllers are used in conjunction with a four-wire, normally open, safety mat where
More informationZelio Control-modular measurement and control relays 1
Presentation, description 1 106439 RM35 TM111MW Presentation Motor temperature measurement and 50MW and RM35 TM250MW monitor the following, on 3-phase supplies: correct sequencing of phases L1, L2 and
More information1. Introduction. 2. Design. Safety and Emergency Stop Circuit Design Standard. Safety and Emergency Stop Circuit Design Standard.
Safety and Emergency Stop Circuit Design Standard The Safety and Emergency Stop Circuit Design Standard provide design criteria and specifications for safety and emergency stop circuits used in General
More informationSAFETY RELAY YRB-4EML-31S MAIN FEATURES
SAFETY RELAY TYPE 4 SAFETY PROTECTION DEVICE FOR SAFETY LIGHT CURTAINS/BARRIERS MAIN FEATURES For safety light curtains and access control barriers, emergency stop, door switch Safety Integrity Level (SIL)
More informationPowerFlex 400 AC Drive Guide Specification
PowerFlex 400 AC Drive Guide Specification Adjustable Frequency Drives with Bypass 3.0 50HP @ 208V AC 3.0 350HP @ 480V AC PART 1 GENERAL 1.01 Quality Assurance A. The manufacturer shall have minimum 5
More information42JS & 42JT VisiSight
JS & JT VisiSight mm Rectangular General Specifications Certifications culus Listed and CE Marked for all applicable directives 7-Encoders PHOTOSWITCH Photoelectric Shock g with ms pulse duration, meets
More informationBulletin 871L & 872L Limit Switch Style
Bulletin 871L & 872L Description Bulletin 871L and 872L inductive proximity sensors are selfcontained, general purpose, solid state devices designed to sense the presence of metal objects (ferrous and
More informationNE1A/DST1. DeviceNet Safety System
System Omron now offers a DeviceNet compatible Safety System, that can be used 3-ways: as a Standalone controller, as a Safety network expandable with remote I/O blocks, or combined with DeviceNet to form
More informationIRB-MON O P E R A T I N G I N S T R U C T I O N S UNIVERSAL SAFETY PHOTOEYE U L M O N I T O R E D DEVICE
O P E R A T I N G I N S T R U C T I O N S IRB-MON UNIVERSAL SAFETY PHOTOEYE U L 3 2 5-2 0 1 6 M O N I T O R E D DEVICE 4564 Johnston Parkway, Cleveland, Ohio 44128 P. 800 426 9912 F. 216 518 9884 Sales
More informationDatasheet - AZM300Z-ST-1P2P-A
08.04.2015-16:04:56h Datasheet - AZM300Z-ST-1P2P-A Solenoid interlock / AZM300 Suitable for mounting to profile systems Thermoplastic enclosure 3 different directions of actuation Compact design 3 LEDs
More informationDriveGuard. Safe-Off Option for PowerFlex 70 AC Drives. User Manual.
DriveGuard Safe-Off Option for PowerFlex 70 AC Drives User Manual www.abpowerflex.com Important User Information Solid state equipment has operational characteristics differing from those of electromechanical
More informationFor full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.
R Safety Interlock Switches TL8012-S TL8012 For full product information, visit www.sti.com. Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page. Versatile Safety Interlock
More informationDigital ac/dc (24V) Input Module
Installation Instructions Digital ac/dc (24V) Input Module Catalog Number 1771-IND, Series C Topic Page Important User Information 2 Before You Begin 3 Power Requirements 3 Prevent Electrostatic Discharge
More informationControl unit SG-EFS 104/4L. EN Operating instructions. Innovative by tradition. Version SG-EFS 104/4L AC/DC 24 V
Innovative by tradition. Control unit SG-EFS 104/4L EN Operating instructions Version 2 1004128 SG-EFS 104/4L AC/DC 24 V Original instructions Mayser GmbH & Co. KG Örlinger Straße 1 3 89073 Ulm GERMANY
More informationGV-EL124S Electric Strike
GV-EL124S Electric Strike Featured with a built-in door status sensor, the GV-EL124S is a fail-secure electric strike, but it is field convertible from fail secure to fail safe. It can be mounted either
More informationDeviceNet ArmorBlock Network Powered 16-input Module, Series A
Installation Instructions DeviceNet ArmorBlock Network Powered 16-input Module, Series A Catalog Number 1732D-IB161212D Topic Page Important User Information 2 Environment and Enclosure 3 Prevent Electrostatic
More informationAllen-Bradley Automation
Product Data 1791D CompactBlock I/O for DeviceNet 1791D CompactBlock I/O modules contain I/O circuits, a built-in power supply, and a built-in DeviceNet I/O adapter. CompactBlock I/O modules are ideal
More informationBulletin 871D Cylinder Position Inductive Style
Bulletin 871D Cylinder Position Inductive Style Description Bulletin 871D cylinder position inductive proximity sensors are self-contained solid state devices. These devices are designed for sensing metal
More informationNHP SAFETY REFERENCE GUIDE
NHP SAFETY REFERENCE GUIDE GSR SAFETY FUNCTION DOCUMENTS 2 Hand Control Safety Function 800Z Zero Force Buttons / MSR125 Safety Relay / GSR SI Safety Relay Table of Contents: Introduction 6-3 Important
More information3-14. General 1-2-Opto-electronics 3-Interlock. Switches. Operator. Interface. Logic Power. Safety Switches Tongue Switches Cadet 3.
General 1-2-Opto-electronics 3-Interlock Description The Cadet 3 is a tongue-operated (or key-operated) safety interlock switch designed to fit at the leading edge of sliding, hinged or lift-off guards.
More informationDeviceNet ArmorBlock Network and Auxiliary Powered I/O Module
Installation Instructions DeviceNet ArmorBlock Network and Auxiliary Powered I/O Module Catalog Number 1732D-8X81212D Topic Page Important User Information 2 Environment and Enclosure 3 Prevent Electrostatic
More information1. Summary. 2. Contacts. Safety Controls Guidelines. Table of Contents
The provide design criteria and specifications for safety circuit in compliance with ISO 13849-1 PL d Safety of machinery, used in General Mills manufacturing facilities. Table of Contents 1. Summary 2.