1 Powerware 9125 (9910-E30) UPS Installation Guide for IBM Applications

2 Special Symbols The following are examples of symbols used on the UPS or accessories to alert you to important information: RISK OF ELECTRIC SHOCK - Indicates that a risk of electric shock is present and the associated warning should be observed. CAUTION: REFER TO OPERATOR S MANUAL - Refer to your operator s manual for additional information, such as important operating and maintenance instructions. This symbol indicates that you should not discard the UPS or the UPS batteries in the trash. This product contains sealed, lead-acid batteries and must be disposed of properly. For more information, contact your local recycling/reuse or hazardous waste center. This symbol indicates that you should not discard waste electrical or electronic equipment (WEEE) in the trash. For proper disposal, contact your local recycling/reuse or hazardous waste center. IBM, pseries, AIX, xseries, AS/400, OS/400, and RS/6000 are registered trademarks and iseries, OpenPower, and i5/os are trademarks of International Business Machines Corp. Eaton, Powerware, X-Slot, and LanSafe are registered trademarks and ConnectUPS is a trademark of Eaton Corporation or its subsidiaries and affiliates. Burndy is a registered trademark of Framatone Connectors International. ECopyright 2007 Eaton Corporation, Raleigh, NC, USA. All rights reserved. No part of this document may be reproduced in any way without the express written approval of Eaton Corporation.

3 Table of Contents 1 Installation Parts List UPS Internal Battery Connection Setup and Installation Tools Required Rack-Mount Setup Tower Setup EBM Installation PDM Installation UPS Installation Remote Emergency Power-off Installation Power Connections and Startup Typical Power Connections Load Segments Operation Turning the UPS On Starting the UPS on Battery Turning the UPS Off Initiating the Self-Test Operating Modes Normal Mode Battery Mode Bypass Mode Standby Mode Configuration Mode Communication Single-Port Card Communication Options i5, iseries, or AS/400 and Serial Server Interface Overview Serial (TTY) Interface Overview p5 or pseries with Logical Partitions Interface Overview Service and Support EATON Powerware 9125 (9910-E30) UPS Installation Guide for IBM Applications S Rev 1 i

4 TABLE OF CONTENTS This page intentionally left blank. ii EATON Powerware 9125 (9910-E30) UPS Installation Guide for IBM Applications S Rev 1

5 Chapter 1 Installation IBM part numbers are subject to change without notice. Parts List Table 1. E30 Base Configuration (42R8069) Quantity IBM MN IBM FC IBM PN Eaton PN Description 1 E30 42R E30 UPS 3000 VA, 2100W (in shipping carton or factory-installed in rack)* UPS Front Cover* Read Me First Card (2) Rack Mounting Bracket Kits*: S (2) Mounting Brackets ( ) S (4) Mounting Bracket Screws (M4 8) ( ) S (2) Mounting Handles ( ) S (4) Mounting Handle Screws (#8-32 1/2 ) ( ) Left Rail Assembly* Right Rail Assembly* 1 42R E30 Accessory Kit * If the UPS is factory-installed in an IBM rack, these items are pre-assembled. Table 2. E30 Application Matrix IBM MN IBM FC IBM PN Eaton PN Description i5/ iseriest Tower IEC i5/ iseries Tower NEMA p5/ pseries Tower IEC p5/ pseries Tower NEMA p5/ pseries Rack WW i5/ iseries Rack WW R NEMA PowerPass Distribution Module (PDM) 2939* 42R Relay-Serial Card and Cable Kit (DB-9, 1.8m/6 ft; DB-25, 9.1m/30 ft) * Maximum: One FC 2934 or 2939 per E30 UPS. NOTE IEC: IEC Countries (e.g., UK, Italy, etc.); NEMA: NEMA Countries (e.g. U.S. and Canada); WW: Worldwide EATON Powerware 9125 (9910-E30) UPS Installation Guide for IBM Applications S Rev 1 1

6 INSTALLATION Table 3. E30 Options Matrix IBM MN IBM FC IBM PN Eaton PN Description i5/ iseries Tower IEC i5/ iseries Tower NEMA p5/ pseries Tower IEC p5/ pseries Tower NEMA p5/ pseries Rack WW i5/ iseries Rack WW 2934* 39J ConnectUPSt-X Web/SNMP Card R Extended Battery Module (EBM) 42R EBM Accessory Kit Min: 0, Max: 1 Min: 0, Max: 4 1 per FC 6644 * Maximum: One FC 2934 or 2939 per E30 UPS. NOTE IEC: IEC Countries (e.g., UK, Italy, etc.); NEMA: NEMA Countries (e.g. U.S. and Canada); WW: Worldwide Table 4. E30 Accessory Kit (42R8070) Quantity Eaton PN Description Powerware 9125 Two-in-One UPS (2500/3000 VA) User s Guide Powerware 9125 (9910-E30) Installation Guide for IBM Applications IEC 320-C13 to C14, 10A Equipment Power Cords (2m/6.6 ft) IEC 320-C19 to C20, 16A Equipment Power Cord (4.5m/14.8 ft) Software Suite CD Serial Cable (DB-9 to DB-9, 1.8m/6 ft) Serial Cable (RJ-45 to DB-9, 1.8m/6 ft) Mounting Handles Mounting Handle Screws (#8-32 1/2 ) Pedestals PedestalMounting Screws (M4 10 mm) Rail Hardware Kit (metric): S (8) M5 12 Pan-Head Screws S (8) M5 10 Flat-Head Screws S (4) M5 16 Hex-Head Screws S (4) M5 Clip Nuts S (2) Square-Hole Adapter Plates 2 EATON Powerware 9125 (9910-E30) UPS Installation Guide for IBM Applications S Rev 1

7 INSTALLATION Table 5. E EBM Components (42R8071) Quantity IBM MN IBM FC IBM PN Eaton PN Description R E EBM 2U High (in shipping carton or factory-installed in rack)* EBM Front Cover* (2) Mounting Brackets* (4) Mounting Bracket Screws (M4 8)* Left Rail Assembly* Right Rail Assembly* 1 42R EBM Accessory Kit * If the EBM is factory-installed in an IBM rack, these items are pre-assembled. Table 6. E EBM Accessory Kit (42R8072) Quantity Eaton PN Description Powerware 9125 Two-in-One EBM (2500/3000 VA) User s Guide Mounting Handles Mounting Handle Screws (#8-32 1/2 ) Joining Brackets Joining BracketScrews (M4 10 mm) EBM Fixed Cover Plate Pan-Head Screws (M3 6 mm) Rail Hardware Kit (metric): S (8) M5 12 Pan-Head Screws S (8) M5 10 Flat-Head Screws S (4) M5 16 Hex-Head Screws S (4) M5 Clip Nuts S (2) Square-Hole Adapter Plates EATON Powerware 9125 (9910-E30) UPS Installation Guide for IBM Applications S Rev 1 3

8 INSTALLATION Table 7. FC 6570 PDM (42R4320) Quantity Eaton PN Description FC 6570 PDM Powerware 9125 PDM (2500/3000 VA) User s Guide Accessory Kit: S (1) 2.5m (8 ft) IEC 320-C19 to IEC 320-C20 Jumper Cable ( ) S (2) Joining Brackets ( ) S (4) Joining Bracket Screws (M4 10 mm) ( ) UPS Internal Battery Connection NOTE Check the battery recharge date on the shipping carton label. If the date has expired and the batteries were never recharged, do not use the UPS. Contact your service representative. To ensure proper battery operation before installing the UPS: 1. Verify that the UPS is off and unplugged. 2. Remove the UPS front cover (see Figure 1). Figure 1. Removing the Front Cover 3. Connect the internal battery connector (see Figure 2). Figure 2. Connecting the Internal Battery Connector 4 EATON Powerware 9125 (9910-E30) UPS Installation Guide for IBM Applications S Rev 1

9 INSTALLATION 4. Reinstall the UPS front cover (see Figure 3). Figure 3. Reinstalling the Front Cover Setup and Installation The E30 UPS is designed for flexible configurations and can be installed in a rack, as a standalone cabinet, or in a tower configuration. NOTE For UPS rack installations: If the UPS is pre-installed in an IBM rack, continue to UPS Installation on page 18. If you are installing the UPS in an IBM iseries (0550, 0551, 0554, or 0555 types) or pseries (7014 type) rack, continue to the following section, Tools Required. If you have another type of rack, contact your service representative (see page 49). NOTE For UPS standalone cabinet or tower installations: Continue to Tower Setup on page 11 to begin the UPS setup. Tools Required To assemble the components, the following tools may be needed: S Medium flat-bladed screwdriver S #2 Phillips screwdriver S 7and8mmwrenchorsocket Rack-Mount Setup The rail kit can be installed in 48-cm (19-inch) racks and needs only 2U of valuable rack space. NOTE Mounting rails are required for each individual cabinet and are located in the UPS and EBM cartons. All hardware is supplied. NOTE The UPS and any optional cabinets MUST be installed at the bottom of the rack. If placed in a rack with existing equipment, the rack must be reconfigured to allow the UPS installation at the bottom of the rack. EATON Powerware 9125 (9910-E30) UPS Installation Guide for IBM Applications S Rev 1 5

10 INSTALLATION Each rail kit requires one (1) of each item in the following list: S Left rail assembly (located in the UPS and EBM cartons) S Right rail assembly (located in the UPS and EBM cartons) S Rack mounting bracket kit (located in the UPS and EBM cartons) S Rail hardware kit (located in the E30 UPS and EBM accessory kits) To install the rail kit(s): 1. Loosen the assembly wing nuts on both rail assemblies and adjust the rail size for the depth of your rack (see Figure 4). Rear Hold-Down Bracket Front Rear Assembly Wing Nuts Figure 4. Adjusting the Rail Depth 2. Select the proper holes in the rail for positioning the UPS and any optional cabinets in the rack. 3. Secure the rail to the front of the rack with two pan-head screws and one adapter plate. Insert the screws through positions 3 and 4 oftherail(seefigure5). NOTE Do not tighten the screws until the UPS or EBM is installed. 6 EATON Powerware 9125 (9910-E30) UPS Installation Guide for IBM Applications S Rev 1

11 INSTALLATION Assembly Wing Nuts Adapter Plate Position 4 Position 3 Front Rail Pan-Head Screws Figure 5. Securing the Front of the Rail 4. Using two clip nuts and two hex-head screws, attach the rail to the rear of the rack (see Figure 6 and Figure 7). The bottom rail uses positions 2 and 4 for the rear hex-head screws. If you are installing additional rails, place the next rail 4 holes above the last installed screw. EATON Powerware 9125 (9910-E30) UPS Installation Guide for IBM Applications S Rev 1 7

12 INSTALLATION Position 10 Position 8 Second Rail Position 4 Position 2 First Rail Figure 6. Rear Rail Screw Positions Figure 7. Securing the Rear of the Rail 5. Repeat Steps 3 and 4 for the other rail. 6. Tighten the assembly wing nuts on both rail assemblies. 7. Place the UPS on a flat, stable surface with the front of the UPS facing toward you. 8 EATON Powerware 9125 (9910-E30) UPS Installation Guide for IBM Applications S Rev 1

13 INSTALLATION 8. Attach the supplied mounting handles to the mounting brackets and secure with the supplied #8-32 1/2 flat-head screws (see Figure 8). 9. Align the mounting brackets with the screw holes on the side of the UPS and secure with the supplied M4 8 flat-head screws (see Figure 8). 10. If installing optional cabinets, repeat Steps 7 through 9 for each cabinet. #8-32 1/2 flat-head screws Mounting Handle Mounting Bracket M4 8 flat-head screws Figure 8. Installing the Mounting Handles and Brackets CAUTION The UPS (37 kg/81.5 lb), EBM (42.5 kg/93 lb), and PDM (34.5 kg/76 lb) are heavy. A minimum of two people are required to lift the cabinets into the rack. NOTE The PDM must be installed above the UPS. The EBMs must be installed below the UPS as shown in Figure 9. PDM UPS EBM Figure 9. Rack-Mount UPS with PDM and EBM EATON Powerware 9125 (9910-E30) UPS Installation Guide for IBM Applications S Rev 1 9

14 INSTALLATION 11. Slide the UPS and any optional cabinets into the rack. 12. Secure the front of the cabinets to the rack using two pan-head screws on each side (see Figure 10). Position 6 Position 1 Figure 10. Securing the Front of the Cabinet 13. Loosen the wing nut on each rear hold-down bracket and slide the bracket over the rear of the cabinet. Tighten the wing nut. Rear Hold-Down Bracket Figure 11. Securing the Back of the Cabinet 14. Tighten the pan-head screws that secure both rails to the front of therack(seestep3onpage6). 15. Continue to EBM Installation on page 15, PDM Installation on page 17, or Power Connections and Startup on page EATON Powerware 9125 (9910-E30) UPS Installation Guide for IBM Applications S Rev 1

15 INSTALLATION Tower Setup The UPS and any optional cabinets (PDM or EBM) must be stabilized with pedestals or joining brackets. The setup varies depending on the number of cabinets you are installing: 1. For one cabinet, both sets of pedestals must be installed (provided in the E30 accessory kit). Complete Steps 2 through 4. For two cabinets, the pedestals and joining brackets must be installed. Skip to Step 5 or 6. For three or more cabinets, the pedestals are not installed. Skip to Step 8 to install the joining brackets. 2. Place the UPS horizontally, so that the left end of the cabinet is accessible (see Figure 12). 3. Align the pedestals over the holes on the end of the UPS as shown in Figure 12. Secure the pedestals with the screws provided in the accessory kit. Figure 12. Installing UPS Pedestals (for One Cabinet) 4. Carefully position the cabinet upright with the air vents at the top (see Figure 13). Continue to UPS Installation on page 18. EATON Powerware 9125 (9910-E30) UPS Installation Guide for IBM Applications S Rev 1 11

16 INSTALLATION Air Vents Figure 13. Pedestals with One Cabinet 5. UPS with EBM: Place the UPS horizontally so that the left end of the cabinet is accessible (see Figure 14). Figure 14. Installing UPS Pedestals Place the EBM upside down so that the right end of the cabinet is accessible (see Figure 15). Figure 15. Installing EBM Pedestals 12 EATON Powerware 9125 (9910-E30) UPS Installation Guide for IBM Applications S Rev 1

17 INSTALLATION 6. UPS with PDM: Place the PDM horizontally so that the left end of the cabinet is accessible (see Figure 16). Figure 16. Installing PDM Pedestals Place the UPS upside down so that the right end of the cabinet is accessible (see Figure 17). Figure 17. Installing UPS Pedestals 7. Position two of the pedestals over the edge of each cabinet so that the weight of the unit is evenly distributed. Secure the pedestals with the screws provided in the accessory kit. 8. Carefully position the cabinets upright with the air vents at the top (see Figure 18 or Figure 19). Air Vents UPS with EBM UPS with PDM Figure 18. Pedestals with Two Cabinets EATON Powerware 9125 (9910-E30) UPS Installation Guide for IBM Applications S Rev 1 13

18 INSTALLATION NOTE Pedestals are required for installations with one or two cabinets. Joining brackets are required for installations with two or more cabinets. Air Vents Figure 19. Tower Setup with Three Cabinets 9. Align each joining bracket with the adjacent corner screw holes and secure with the supplied screws (see Figure 20). UPS EBM Joining Bracket Joining Bracket Figure 20. Installing the Joining Brackets (Top View with Pedestals) 10. If installing additional cabinets, repeat Step 9 for each cabinet. 11. Continue to the following section, EBM Installation or PDM Installation on page EATON Powerware 9125 (9910-E30) UPS Installation Guide for IBM Applications S Rev 1

19 INSTALLATION EBM Installation CAUTION A small amount of arcing may occur when connecting an EBM to the UPS. This is normal and will not harm personnel. Insert the EBM cable into the UPS battery connector quickly and firmly. To install the optional EBM(s): 1. The UPS has a battery connector cover that must be removed before installing the EBM(s). Remove the cover from the rear panel as shown in Figure 21. NOTE Keep the battery connector cover and screws for future use. If the UPS is stored or used without an EBM, the battery connector cover must be installed as a safety precaution. Battery Connector Cover Screws Figure 21. Battery Connector Cover 2. Remove the cover from the EBM cable as shown in Figure 22. NOTE Keep the EBM cable cover and screws for future use. If the EBM is stored or removed from the UPS, the EBM cable cover must be installed as a safety precaution. EBM Cable with Cover Figure 22. EBM Cable Cover EATON Powerware 9125 (9910-E30) UPS Installation Guide for IBM Applications S Rev 1 15

20 INSTALLATION 3. Plug the EBM cable into the UPS battery connector (see Figure 23). 4. Attach the fixed cover plate (supplied in the EBM accessory kit) to the EBM cable as shown in Figure 23. UPS Battery Connector EBM Cable EBM Cable with Fixed Cover Plate EBM Battery Connector with Cover Fixed Cover Plate Figure 23. Typical EBM Installation 5. If additional EBMs are to be installed, remove the EBM battery connector cover. Remove the cover from the EBM cable of the second cabinet and plug the EBM cable into the battery connector on the first EBM. Attach the fixed cover plate to the EBM cable. Repeat for each additional EBM. Up to four EBMs may be connected to the UPS. 6. Continue to the following section, PDM Installation or UPS Installation on page EATON Powerware 9125 (9910-E30) UPS Installation Guide for IBM Applications S Rev 1

21 INSTALLATION PDM Installation To install the optional FC 6570 PDM: 1. Verify that the bypass switch on the PDM is in the NORMAL position (see Figure 24). 2. Select the input voltage (208 or 240V) using the Voltage Selector Switch according to the utility voltage: S Utility voltage V, select 208V S Utility voltage V, select 240V NOTE The output of the PDM is 120/240V while the UPS and utility inputs are V. 3. Verify that the power cord provided with the IBM equipment is detached from the UPS input connector. Retain the cord for future use. 4. Connect the jumper cable (provided in the PDM accessory kit) from the 16A UPS output receptacle into the UPS-output connector on the PDM. 5. Plug the attached PDM-to-UPS cord into the input connector on the UPS rear panel. Power Cord Input Connector Bypass Switch PDM-to-UPS Cord PDM Output Circuit Breaker Voltage Selector Switch UPS-Output Connector PDM Output Receptacles (Two L6-15R) Output Receptacles (Two 5-15R) Output Receptacles (Four 6-20R) UPS UPS Battery Connector UPS Output Receptacle (16A, IEC 320-C19) UPS Input Connector (16A, IEC-320) Figure 24. UPS and PDM Installation (FC 6570 PDM Model Shown) EATON Powerware 9125 (9910-E30) UPS Installation Guide for IBM Applications S Rev 1 17

22 INSTALLATION UPS Installation NOTE Do not make unauthorized changes to the UPS; otherwise, damage may occur to your equipment and void your warranty. To install the UPS: 1. If you are installing power management software, connect your computer to the UPS communication port or optional X-Slot card (see Table 15 on page 44). For the communication port, use only the serial cable supplied in the E30 accessory kit. Battery Connector with Cover REPO Port Circuit Breaker Communication Port X-Slot Communication Bay Output Receptacles (Four 10A, IEC 320-C13) UPS Output Receptacle (16A, IEC 320-C19) UPS Input Connector (16A, IEC-320) Figure 25. UPS Rear View 2. If an emergency power-off (disconnect) switch is required by local codes, see the following section, Remote Emergency Power-off Installation to install the REPO switch before powering on the UPS. 3. Continue to Power Connections and Startup on page 20. Remote Emergency Power-off Installation The E30 includes a REPO port that allows power to be switched off at the UPS output receptacles from a customer-supplied switch in a remote location. The REPO feature shuts down the protected equipment immediately and does not follow the orderly shutdown procedure initiated by any power management software. Any devices that are operating on battery power are also shut down immediately. When the REPO switch is reset, the equipment will not return to battery power until the UPS is manually restarted. 18 EATON Powerware 9125 (9910-E30) UPS Installation Guide for IBM Applications S Rev 1

23 INSTALLATION If the Off button is pressed after the REPO is activated, the UPS remains in Standby mode when restarted until the On button is pressed. WARNING The REPO circuit is an IEC safety extra low voltage (SELV) circuit. This circuit must be separated from any hazardous voltage circuits by reinforced insulation. CAUTION To ensure the UPS stops supplying power to the load during any mode of operation, the input power must be disconnected from the UPS when the emergency power-off function is activated. NOTE The REPO function activates when the REPO contacts close. NOTE If the REPO function is not needed, the REPO connector must remain installed in the REPO port on the UPS rear panel. NOTE For Europe, the emergency switch requirements are detailed in Harmonized document HD S1, Electrical Installation of the Buildings, Part 4: Protection for Safety, Chapter 46: Isolation and Switching. To install the REPO switch: 1. Verify that the UPS is off and unplugged. 2. Remove the REPO connector from the REPO port on the UPS rear panel. 3. Connect isolated, normally-open, dry contacts (rated to handle 60 Vdc maximum, 30 Vac RMS maximum, and 20 ma maximum) across the REPO device to Pin 1 and Pin 2 (see Figure 26). Use stranded, non-shielded wiring, size 0.75 mm mm 2 (18 20 AWG). NOTE A separate contact must simultaneously cause UPS input AC power to be removed. EATON Powerware 9125 (9910-E30) UPS Installation Guide for IBM Applications S Rev 1 19

24 INSTALLATION 4. Reconnect the REPO connector to the REPO port. Pin 1 Pin 2 Figure 26. REPO Connector 5. Verify that the externally-connected REPO switch is not activated to enable power to the UPS output receptacles. 6. Plug in the UPS and start the UPS by pressing the On button. 7. Activate the external REPO switch to test the REPO function. 8. De-activate the external REPO switch and restart the UPS. Power Connections and Startup The device power cord connection(s) determines if the setup can provide dual-redundant power to the protected device(s). See Figure 27 for a non-redundant powered device, Figure 28 for a dual-redundant powered device, or Figure 29 for a UPS providing non-redundant power to a device with redundant power supplies. Legend (Figure 27, Figure 28, and Figure 29) 1 UPS to utility (mains) power cord 2 Device to UPS power cord 3 Device to utility (mains) power cord 20 EATON Powerware 9125 (9910-E30) UPS Installation Guide for IBM Applications S Rev 1

25 INSTALLATION Server/Device UPS Mains 1 2 Figure 27. Connecting Server/Device with One Power Cord (Non-Redundant) to UPS Server/Device UPS TVSS Protected or Second UPS Mains Mains Figure 28. Connecting Server/Device with Two Power Cords (Dual-Redundant) to UPS Server/Device UPS 2 Mains 1 Figure 29. Connecting Server/Device with Two Power Cords (Redundant) to UPS 1. UPS Only: If you are installing a UPS and non-redundant power to the device(s) is desired, plug all the equipment into the UPS output receptacles using the power cords located in the power cord kit (see Figure 30 on page 24). Distribute the load evenly between the rows of receptacles on the UPS. If you are installing a UPS and dual-redundant power to the device(s) is desired, plug the minimum number of power cord(s) required to operate the device into the UPS output receptacles using the power cords located in the power cord kit (see Figure 31 on page 25). Then, plug the remaining (redundant) power cord(s) into a non-ups protected output receptacle (e.g., PDU or mains) or a second UPS. Distribute the load evenly between the rows of receptacles on the UPS. NOTE The redundant power source must be protected with Transient Voltage Surge Suppression (TVSS). EATON Powerware 9125 (9910-E30) UPS Installation Guide for IBM Applications S Rev 1 21

26 INSTALLATION 2. UPS and FC 6570 PDM: If you are installing a UPS and a PDM and non-redundant power to the device(s) is desired, plug all the equipment into the PDM output receptacles (see Figure 33 on page 28) using the original device power cords (see Table 8 for IBM plug types supported). Distribute the load evenly between the rows of receptacles on the PDM. If you are installing a UPS and a PDM and dual-redundant power to the device(s) is desired, plug the minimum number of power cord(s) required to operate the device into the PDM output receptacles (see Figure 33 on page 28) using the original device power cords (see Table 8 for IBM plug types supported). Then plug the remaining (redundant) power cord(s) into a non-ups protected output receptacle (e.g., PDU or mains) or a second UPS with a PDM using device power cords. Distribute the load evenly between the rows of receptacles on the PDM. NOTE The PDM allows a UPS to be removed for service while providing conditioned power to the protected device(s). NOTE The redundant power source must be protected with Transient Voltage Surge Suppression (TVSS). Table 8. FC 6570 PDM Plug Types Supported IBM Plug Type Description Quantity Supported 4 NEMA 5-15P 2 5 NEMA 6-15P 29 NEMA 6-20P 4 10 NEMA L6-15P 2 NOTE If the IBM plug type selected with the equipment to be protected is not contained in this table, change/order the plug type on the equipment to match the plug types supported. NOTE DO NOT protect laser printers with the UPS because of the exceptionally high power requirements of the heating elements. 22 EATON Powerware 9125 (9910-E30) UPS Installation Guide for IBM Applications S Rev 1

27 INSTALLATION 3. UPS Only: Plug the power cord provided with the IBM equipment into the input connector on the UPS rear panel (see Figure 30 on page 24). UPS with PDM: Plug the power cord provided with the IBM equipment into the input connector on the PDM rear panel (see Figure 33 on page 28). 4. Plug the other end of the power cord into a power outlet. All UPS front panel indicators flash briefly and the UPS conducts a self-test. When the self-test is complete, the μ indicator flashes, indicating the UPS is in Standby mode. 5. Press the On button. The μ indicator stops flashing and the bar graph indicators display the percentage of load being applied to the UPS. The UPS is now in Normal mode and supplying power to your equipment. To change the factory-set defaults, see Configuration Mode on page 37. NOTE The batteries charge to 90% capacity in approximately 3 hours. However, it is recommended that the batteries charge for 24 hours after installation or long-term storage. If you have questions about implementing non- or dual-redundant power, the following options are available: S View the circuit diagrams at and select Products > 9910 UPS for System i > E30 > Product Literature S Submit your question to Ask the Expert at S Submit your question to our FAQ database at and select General Knowledge > Frequently Asked Questions S Contact the IBM office or Business Partner servicing your account EATON Powerware 9125 (9910-E30) UPS Installation Guide for IBM Applications S Rev 1 23

28 INSTALLATION Typical Power Connections Table 9. Typical Power Connections (Figure 30) Item Description 1 IEC 320-C20 2 IEC 320-C19 3 IEC 320-C14 4 IEC 320-C13 5 Country-specific power (mains) cord IBM FC Plug Type Description NEMA L6-20P NEMA L6-20P CEE7 VII SABS CEI IEC309 (P+N+G) 16A SII SAA-AS IRAM Output power (UPS to device) cords, located in the E30 accessory kit Qty. 4 IEC 320-C13 to C14, 1.8m (6 ft) 1 IEC 320-C19 to C20, 2.7m (9 ft) IBM iseries or pseries Device IBM iseries or pseries Device(s) Eaton (6) Eaton (6) E W UPS 1 2 IBM 5 Mains Varies 5 Figure 30. E30 International (IEC) Tower and Worldwide Rack Non-Redundant Power 24 EATON Powerware 9125 (9910-E30) UPS Installation Guide for IBM Applications S Rev 1

29 INSTALLATION Table 10. Typical Power Connections (Figure 31) Item Description 1 IEC 320-C20 2 IEC 320-C19 3 IEC 320-C14 4 IEC 320-C13 5 Country-specific power (mains) cord IBM FC Plug Type Description NEMA L6-20P NEMA L6-20P CEE7 VII SABS CEI IEC309 (P+N+G) 16A SII SAA-AS IRAM Output power (UPS to device) cords, located in the E30 accessory kit Qty. 4 IEC 320-C13 to C14, 1.8m (6 ft) 1 IEC 320-C19 to C20, 2.7m (9 ft) 7 Varies: Device country-specific power (mains) cord Dual-redundant power options: 1. Device or PDU to mains (no UPS protection), then MUST have Transient Voltage Surge Suppression (TVSS) on mains. 2. Second E30. 7 Mains with TVSS IBM 1 Second E30 or PDU 7 IBM IBM iseries or pseries Device IBM iseries or pseries Device(s) Eaton (6) Eaton (6) E W UPS 2 IBM 5 Mains Varies 5 Figure 31. E30 International (IEC) Tower and Worldwide Rack Dual-Redundant Power EATON Powerware 9125 (9910-E30) UPS Installation Guide for IBM Applications S Rev 1 25

30 INSTALLATION Table 11. Typical Power Connections (Figure 32) Item Description 1 IEC 320-C20 2 IEC 320-C19 3 IEC 320-C14 4 IEC 320-C13 5 Country-specific power (mains) cord IBM FC Plug Type Description NEMA L6-20P NEMA L6-20P CEE7 VII SABS CEI IEC309 (P+N+G) 16A SII SAA-AS IRAM Output power (UPS to device) cords, located in the E30 accessory kit Qty. 4 IEC 320-C13 to C14, 1.8m (6 ft) 1 IEC 320-C19 to C20, 2.7m (9 ft) 7 Varies: Device country-specific power (mains) cord 26 EATON Powerware 9125 (9910-E30) UPS Installation Guide for IBM Applications S Rev 1

31 INSTALLATION Dual-redundant power options: 1. Device or PDU to mains (no UPS protection), then MUST have Transient Voltage Surge Suppression (TVSS) on mains. 2. Second E30. IBM iseries or pseries Device IBM iseries or pseries Device(s) Eaton (6) 2 IBM 7 7 Mains E W UPS 1 2 IBM 4 Eaton (6) Eaton (6) 3 4 OR 4 IBM 7 OR Eaton (6) PDU 7 IBM 5 7 Mains Varies 5 Mains Varies 7 (TVSS Protected) Figure 32. E30 International (IEC) Tower and Worldwide Rack Dual-Redundant Power EATON Powerware 9125 (9910-E30) UPS Installation Guide for IBM Applications S Rev 1 27

32 INSTALLATION Table 12. Typical Power Connections (Figure 33) Item Description Plug Type 1 IEC 320-C20 2 IEC 320-C19 3 NEMA 6-15P 4 NEMA 6-20P 5 NEMA 6-20R T (6-15P or 6-20P) 5/29 6 IEC 320-C14 7 IEC 320-C13 8 NEMA 5-15P 9 NEMA 5-15R 4 10 NEMA L6-15R NEMA L6-15P 12 Country-specific power (mains) cord IBM FC Plug Type Description NEMA L6-20P NEMA L6-20P IBM iseries or pseries Device(s) IBM iseries or pseries Device(s) IBM 3/4 2 IBM 11 7 IBM 11 7 IBM 3/ E30 UPS 2100W with FC 6570 PDM 1 2 IBM Mains IBM iseries or pseries Device(s) 6 7 IBM 8 9 Figure 33. E30 and FC 6570 PDM NEMA Countries Tower 28 EATON Powerware 9125 (9910-E30) UPS Installation Guide for IBM Applications S Rev 1

33 INSTALLATION Load Segments Load segments are sets of receptacles that can be controlled by power management software, providing an orderly shutdown and startup of your equipment. For example, during a power outage, you can keep key pieces of equipment running while you turn off other equipment. This feature allows you to save battery power. See your power management software manual for details (refer to the Software Suite CD or for the latest information). NOTE If power management software is not used, the individual load segments cannot be controlled. The E30 has two load segments as shown in Figure 34. UPS with PDM: The PDM plugs into Load Segment 2 on the UPS rear panel. NOTE When the PDM is in Bypass mode, all load segments are switched to utility power and cannot be controlled until the PDM bypass switch is returned to the NORMAL position. Load Segment 1 Figure 34. UPS Load Segments Load Segment 2 EATON Powerware 9125 (9910-E30) UPS Installation Guide for IBM Applications S Rev 1 29

34 INSTALLATION This page intentionally left blank. 30 EATON Powerware 9125 (9910-E30) UPS Installation Guide for IBM Applications S Rev 1

35 Chapter 2 Operation This section describes: S Turning the UPS on and off S Starting the UPS on battery S Initiating the self-test S Operating modes Turning the UPS On After the UPS is connected to a power outlet, it conducts a self-test and enters Standby mode. To turn on the UPS, press the On button on the front panel. The μ indicator illuminates solid and the bar graph indicators display the percentage of load being applied to the UPS. Starting the UPS on Battery To turn on the UPS without using utility power, press and hold the On button for at least four seconds. The UPS supplies power to your equipment and goes into Battery mode. When the UPS starts on battery, it does not conduct a self-test to conserve battery power. EATON Powerware 9125 (9910-E30) UPS Installation Guide for IBM Applications S Rev 1 31

36 OPERATION Turning the UPS Off NOTE Pressing the Off down immediately. button while the UPS is in Battery mode causes the UPS to shut To turn off the UPS: 1. Prepare your equipment for shutdown. 2. Press and hold the Off button for approximately three seconds. The UPS transfers to Standby mode (if utility power is available) and removes power from your equipment. 3. Unplug or remove utility power from the UPS; the UPS shuts down in five seconds. All front panel indicators flash briefly prior to shutdown. If you do not unplug or remove utility power from the UPS, it remains in Standby mode. Initiating the Self-Test NOTE The batteries must be fully charged and the UPS must not be in Battery mode to perform the self-test. Press and hold the button for three seconds to initiate the self-test. During the five-second test, the bar graph indicators cycle through twice. If the alarm beeps or a UPS alarm indicator stays on, refer to Troubleshooting in the Powerware 9125 Two-in-One UPS (2500/3000 VA) User s Guide. 32 EATON Powerware 9125 (9910-E30) UPS Installation Guide for IBM Applications S Rev 1

37 OPERATION Operating Modes The Powerware 9125 s front panel indicates the UPS status through the UPS indicators. Figure 35 shows the UPS front panel indicators and controls. Normal Mode Indicator Battery Mode Indicator Bypass Mode Indicator Test/Alarm Reset Button Alarm Indicators Bar Graph Indicators Indicator Legend Unlit Lit Flashing Off Button On Button Figure 35. UPS Front Panel EATON Powerware 9125 (9910-E30) UPS Installation Guide for IBM Applications S Rev 1 33

38 OPERATION Normal Mode During Normal mode, the μ indicator illuminates and the front panel displays the percentage of UPS load capacity being used by the protected equipment (see Figure 36). The UPS monitors and charges the batteries as needed and provides power protection to your equipment. <10% 10 25% 26 50% 51 75% % >100% Figure 36. Load Level Indicators When all of the bar graph indicators are illuminated and the flashes, power requirements exceed UPS capacity; refer to Troubleshooting in the Powerware 9125 Two-in-One UPS (2500/3000 VA) User s Guide for more information. indicator 34 EATON Powerware 9125 (9910-E30) UPS Installation Guide for IBM Applications S Rev 1

39 OPERATION Battery Mode When the UPS is operating during a power outage, the alarm beeps once per second and the indicator illuminates. The front panel displays the approximate percentage of battery capacity remaining (see Figure 37). When utility power returns, the UPS transfers to Normal mode operation while the battery recharges. >75% >50% >25% 3-Minute Warning Shutdown Imminent Figure 37. Battery Capacity Indicators If battery capacity becomes low while in Battery mode, the indicator flashes and the alarm sounds continuously, indicating approximately three minutes of battery time remaining. When shutdown is imminent, the indicator flashes. NOTE Depending on the UPS load, the 3-minute warning may occur before the batteries reach 25% capacity; the front panel immediately displays the 3-minute warning. These warnings are approximate, and the actual time to shutdown may vary significantly. Once these warnings are indicated, immediately complete and save your work to prevent data loss and similar difficulties. When utility power is restored after the UPS shuts down, the UPS automatically restarts. EATON Powerware 9125 (9910-E30) UPS Installation Guide for IBM Applications S Rev 1 35

40 OPERATION Bypass Mode In the event of a UPS overload or internal failure, the UPS transfers your equipment to utility power. Battery mode is not available; however, the utility power continues to be passively filtered by the UPS. The indicator illuminates. The UPS transfers to Bypass mode when: S The UPS has an overtemperature condition. S The UPS has an overload condition of 101 to 150% for 30 seconds. S The UPS detects a fault in the battery or UPS electronics. Standby Mode When the UPS is turned off and remains plugged into a power outlet, the UPS is in Standby mode. The μ indicator flashes and the bar graph indicators are off, indicating that power is not available to your equipment. The battery recharges when necessary. NOTE For V models, the output receptacles may remain electrically live (up to V). Unplug the UPS to ensure power is not available to the output receptacles. 36 EATON Powerware 9125 (9910-E30) UPS Installation Guide for IBM Applications S Rev 1

41 OPERATION Configuration Mode When the UPS is in Configuration mode, the bar graph indicators represent the configuration options. Use the control buttons (On button and button) to modify the UPS configuration. Figure 38 shows the LEDs and Table 13 explains the corresponding options. NOTE The UPS can be configured while in Battery mode. If the UPS transfers to battery power while in Configuration mode, the UPS remains in Configuration mode and indicates Battery mode on the front panel. 1. Press the On button and the button simultaneously for one beep. The UPS transfers to Configuration mode. The bar graph indicators flash briefly and then display the enabled options. 2. Press the On button to scroll through the options. Each time you press the button, the UPS beeps. The LED for the selected option indicates the current setting; flashing represents disabled options (see Figure 38 and Table 13). If you press the On button and nothing happens, the UPS is still in Operation mode. Repeat Step 1 to enter Configuration mode, and then perform Step Press the button ONCE to toggle the selected option on or off. Repeat Steps 2 and 3 for each option. Scrolling past the last LED returns to the first configuration option. NOTE The UPS exits Configuration mode automatically after two minutes of inactivity. 4. Press the On button and the button simultaneously to exit Configuration mode at any time. EATON Powerware 9125 (9910-E30) UPS Installation Guide for IBM Applications S Rev 1 37

42 OPERATION Bar Graph Indicators 3 Press the Test/Alarm Reset button to toggle an option on or off. Test/Alarm Reset Button On Button 2 Press the On button to scroll to the next option. Figure 38. Using Configuration Mode 1 & 4 Press the On and Test/Alarm Reset buttons simultaneously to toggle between Configuration and Operation modes. 38 EATON Powerware 9125 (9910-E30) UPS Installation Guide for IBM Applications S Rev 1

43 OPERATION Table 13. Configuration Mode LEDs and Options Bar Graph Indicators Option LED Status Explanation 230V Nominal Input Voltage 220V Nominal Input Voltage 240V Nominal Input Voltage Site Wiring Fault Alarm AC Input Failure Alarm On (default) Flashing On Flashing (default) On Flashing (default) On (default) Flashing* On (default) Flashing Selectingthisoption changesthenominal inputvoltage to 230V. 230V is disabled; one of the other input voltage options is selected. Selecting this option changes the nominal input voltage to 220V. 220V is disabled; one of the other input voltage options is selected. Selecting this option changes the nominal input voltage to 240V. 240V is disabled; one of the other input voltage options is selected. Alarm sounds when the polarity of the outlet is reversed or the ground connection is missing; have a qualified electrician repair the outlet wiring. Alarm DOES NOT sound when the polarity of the outlet is reversed or the ground connection is missing. * Site Wiring Fault is not available for 230V models; Flashing is the default. Alarm soundswhen thereisan AC inputfailure. Alarm DOES NOT sound when there is an AC input failure. EATON Powerware 9125 (9910-E30) UPS Installation Guide for IBM Applications S Rev 1 39

44 OPERATION This page intentionally left blank. 40 EATON Powerware 9125 (9910-E30) UPS Installation Guide for IBM Applications S Rev 1

45 Chapter 3 Communication This section includes S Single-Port Card information S Communication options Single-Port Card The E30 is factory-installed with a Single-Port Card, enabling connection to a PC for power management control. To establish communication between the UPS and a computer, connect your computer to the UPS communication port using the supplied communication cable. When the communication cable is installed, power management software can exchange data with the UPS. The software polls the UPS for detailed information on the status of the power environment. If a power emergency occurs, the software initiates the saving of all data and an orderly shutdown of the equipment. The cable pins are identified in Figure 39 and the pin functions are described in Table Figure 39. Communication Port EATON Powerware 9125 (9910-E30) UPS Installation Guide for IBM Applications S Rev 1 41

46 COMMUNICATION Table 14. Communication Port Pin Assignment Pin Number SignalName Function Direction from the UPS 1 Low Batt Low Battery relay contact Out 2 TxD Transmit to external device Out 3 RxD Receive from external device In 4 DTR PnP (Plug and Play) from external device (tied to Pin 6) In 5 GND Signal common (tied to chassis) 6 DSR To external device (tied to Pin 4) Out 7 RTS PnP from external device (default) or On Bypass relay contact (jumper-selectable) In / Out 8 AC Fail AC Fail relay contact Out 9 Power Source +V (8 to 24 volts DC power) Out The On-Bypass Relay Contact. You can enable the On-Bypass relay using the jumper on the Single-Port Card. The jumper default is disabled. To enable the On-Bypass relay: 1. Remove the Single-Port Card on the UPS rear panel. Retain the screws (see Figure 40). Figure 40. Removing the Single-Port Card 2. Move the J3 jumper to the AS/400 position to enable the On-Bypass relay as shown in Figure EATON Powerware 9125 (9910-E30) UPS Installation Guide for IBM Applications S Rev 1

47 COMMUNICATION On-Bypass Disabled On-Bypass Enabled NORM AS/400 On-Bypass Relay Jumper (J3) Figure 41. On-Bypass Relay Jumper 3. To prevent electrostatic discharge (ESD), place one hand on a metal surface such as the UPS rear panel. Align the Single-Port Card with the slot guides and slide the card into the slot until it is firmly seated. 4. Secure the Single-Port Card with the screws removed in Step 1. EATON Powerware 9125 (9910-E30) UPS Installation Guide for IBM Applications S Rev 1 43

48 COMMUNICATION Communication Options Table 15. Communication Options If you want the UPS to communicate with your computer, use Table 15 to determine which communication option is correct for your application. Application Software Suite CD and Serial Cable ConnectUPS-X Web/SNMP Card Kit (FC 2934) Relay-Serial Card and Cable Kit (FC 2939) IBM i5/iseries Server X IBM i5/iseries Server and Serial Server (Microsoft Windows, Linux,AIX, or other operating systems) IBM p5/pseries Server, OpenPowert, or xseries Server with Single Serial (TTY) Connection IBM p5/pseries Server, OpenPower, or xseries Server with LPARs and/or Network (WebServer) Connection (UPS as a node) X X X Follow the installation instructions with the Software Suite CD or the applicable card kit. This section shows the communication option overviews. For additional information and a current listing of supported operating systems, go to If you connect your computer to the UPS and use the Software Suite CD, you can configure the UPS to recognize the number of EBMs installed: 1. Verify that your computer is connected to the UPS communication port using the supplied cable. 2. Install the Virtual Front Panel software from the supplied Software Suite CD. 3. Configure the Virtual Front Panel software for the correct communication port (COM1 or COM2) on your PC. 4. Select the Battery tab, then select the number of EBMs you are using from the pull-down menu (you can choose up to four EBMs). 5. Click OK and close the software. 44 EATON Powerware 9125 (9910-E30) UPS Installation Guide for IBM Applications S Rev 1

49 COMMUNICATION i5, iseries, or AS/400 and Serial Server Interface Overview To connect the UPS to an i5, iseries, or AS/400 and a serial server you need: S An Eaton-supplied Relay-Serial Card, an AS/400 interface cable (labeled ), and a serial interface cable (labeled ), located in the FC 2939 carton labeled Cable Kit for IBM iseries and Windows or AIX/Linux Servers S For the i5 only: An IBM-supplied UPS interface cable (labeled 1827), included with the server S For the serial server only: Powerware LanSafe Power Management Software from the Software Suite CD, located in the E30 accessory kit Follow the instructions included with the Relay-Serial Card and Cable Kit to install the card and set UPS monitoring functions in i5/os and serial (TTY) server. Installation may include removal of an existing X-Slot card from the UPS. Follow the software installation instructions contained on the Software Suite CD to install the Powerware LanSafe software. If you have an i5, connect the cables as shown in Figure 42. Otherwise, see Figure 43 to connect the cables. Serial (TTY) Server IBM i5 Server P1-T1 UPS Port UPS Interface Cable (labeled 1827) Serial Interface Cable (labeled ) Communication Port AS/400 Interface Cable (labeled ) Relay-Serial Card UPS Figure 42. i5 and Serial Server Interface EATON Powerware 9125 (9910-E30) UPS Installation Guide for IBM Applications S Rev 1 45

50 COMMUNICATION Serial (TTY) Server Serial Interface Cable (labeled ) IBM iseries Server J14 UPS Port (location may vary by model) Communication Port AS/400 Interface Cable (labeled ) Relay-Serial Card UPS Figure 43. iseries or AS/400 and Serial Server Interface 46 EATON Powerware 9125 (9910-E30) UPS Installation Guide for IBM Applications S Rev 1

51 COMMUNICATION Serial (TTY) Interface Overview To serially (TTY) connect the UPS to a p5, pseries, RS/6000, OpenPower or other system you need: S An Eaton-supplied serial interface cable (labeled ), located in the E30 accessory kit S Powerware LanSafe Power Management Software from the Software Suite CD, located in the E30 accessory kit For p5 installations, you also need: S An IBM-supplied 2-port Asynchronous EIA adapter (FC 5723) installed on a p5 server (the pseries does not require an EIA adapter) S An IBM-supplied maintenance package for AIX 5.2L V5.2 (APAR IY66260); or the maintenance package for AIX 5.3L V5.3 (APAR IY62267) Follow the software installation instructions contained on the Software Suite CD to install the Powerware LanSafe software. Connect the serial cable as shown in Figure 44. IBM p5 Server Serial Interface Cable (labeled ) Communication Port 2-Port Asynchronous EIA Adapter (FC 5723) UPS Figure 44. Serial (TTY) Interface EATON Powerware 9125 (9910-E30) UPS Installation Guide for IBM Applications S Rev 1 47

52 COMMUNICATION p5 or pseries with Logical Partitions Interface Overview To connect the UPS to a p5 or pseries with LPARs you need: S An Eaton-supplied ConnectUPS-X Web/SNMP Card, located in the FC 2934 carton labeled ConnectUPS-X Web/SNMP Card Kit S NetWatch software from the Software Suite CD, located in the E30 accessory kit S A customer-supplied Ethernet cable S An available Ethernet port on the server Follow the instructions included with the ConnectUPS-X Web/SNMP Card Kit to install the card and set UPS monitoring functions. Installation may include removal of an existing X-Slot card from the UPS. Follow the software installation instructions contained on the Software Suite CD to install the NetWatch software onto each LPAR. Connect the Ethernet cable as shown in Figure 45. IBM p5 Server Ethernet Cable (customer-supplied) Ethernet Connectors The server must have an available Ethernet port. ConnectUPS-X Web/SNMP Card UPS Figure 45. p5 or pseries with LPARs Interface 48 EATON Powerware 9125 (9910-E30) UPS Installation Guide for IBM Applications S Rev 1

53 Chapter 4 Service and Support In the United States and Canada, call IBMSERV ( ). In Europe, the Middle East, and Africa (EMEA); Latin America; or Asia-Pacific, call the IBM office that services your account. Please have your serial, model, and part number ready when you call (see Figure 46). For additional information, see the appropriate user s guide for the UPS, Extended Battery Module (EBM), or PowerPass Distribution Module (PDM). Front Panel Label (S/N Bar Code 39) S991010P3AAA Serial Number Model Number Part Number Serial Number Rear Panel Label IBM/UPS Type-Model/Feature: 9910-E30 (P) IBM P/N: 42R8069 (IBM Part Number Bar Code 39) (Data: P42R8069 [4.5]) (S) Serial Number: P3AAA (Serial Number Bar Code 39) (Data: S991010P3AAA [4.3]) (2P) EC: H89696 (EC Number Bar Code 39) (Data: 2PH89696) [4.6]) Assembled in Taiwan Date of MFG: YYYYMMDD [4.9] Figure 46. Example of IBM Serial Number Labels Comments We welcome your comments about this manual. Please send your questions or suggestions for improvements to ibm.ups@powerware.com. EATON Powerware 9125 (9910-E30) UPS Installation Guide for IBM Applications S Rev 1 49

Powerware 9125 (9910-E64) UPS Installation Guide for IBM Applications

Powerware 9125 (9910-E64) UPS Installation Guide for IBM Applications Powerware 9125 (9910-E64) UPS Installation Guide for IBM Applications Special Symbols The following are examples of symbols used on the UPS or accessories to alert you to important information: RISK OF

More information

Powerware 5125 (9910-E33) UPS Installation Guide for IBM Applications

Powerware 5125 (9910-E33) UPS Installation Guide for IBM Applications Powerware 5125 (9910-E33) UPS Installation Guide for IBM Applications Special Symbols The following are examples of symbols used on the UPS or accessories to alert you to important information: RISK OF

More information

Powerware 5125 (9910-P33) UPS Installation Guide for IBM Applications

Powerware 5125 (9910-P33) UPS Installation Guide for IBM Applications Powerware 5125 (9910-P33) UPS Installation Guide for IBM Applications IBM, pseries, AIX, xseries, AS/400, OS/400, and RS/6000 are registered trademarks and iseries, OpenPower, and i5/os are trademarks

More information

Powerware 5115 (9910-P13 and P14) Communication Options for IBM Applications

Powerware 5115 (9910-P13 and P14) Communication Options for IBM Applications Powerware 5115 (9910-P13 and P14) Communication Options for IBM Applications Special Symbols The following are examples of symbols used on the UPS or accessories to alert you to important information:

More information

HP UPS R/T3000 G2. Overview. Precautions. Kit contents. Installation Instructions

HP UPS R/T3000 G2. Overview. Precautions. Kit contents. Installation Instructions HP UPS R/T3000 G2 Installation Instructions Overview The HP UPS R/T3000 G2 features a 2U rack-mount with convertible tower design and offers power protection for loads up to a maximum of 3300 VA/3000 W

More information

Eaton 9PX PowerPass Distribution Modules and Transformers 9PXTFMR5, 9PXPPDM2, 9PXTFMR11, and 9PXPPDM1 User's Guide

Eaton 9PX PowerPass Distribution Modules and Transformers 9PXTFMR5, 9PXPPDM2, 9PXTFMR11, and 9PXPPDM1 User's Guide Eaton 9PX PowerPass Distribution Modules and Transformers 9PXTFMR5, 9PXPPDM2, 9PXTFMR11, and 9PXPPDM1 User's Guide For use with 9PX 5000/6000/8000/11000 VA UPS Models FCC Part 15 Class A EMC Statements

More information

HP R/T2200 UPS. Overview. Precautions. Installation Instructions. The HP UPS R/T2200 features power protection for loads up to 2200 VA/1600 W.

HP R/T2200 UPS. Overview. Precautions. Installation Instructions. The HP UPS R/T2200 features power protection for loads up to 2200 VA/1600 W. HP R/T2200 UPS Installation Instructions Overview The HP UPS R/T2200 features power protection for loads up to 2200 VA/1600 W. For more information about any of the topics covered in this document, see

More information

hp uninterruptible power system r12000 xr models installation instructions

hp uninterruptible power system r12000 xr models installation instructions hp uninterruptible power system r000 xr models installation instructions Overview These instructions show how to install an uninterruptible power system (UPS). For detailed information about the UPS, refer

More information

powerware 5105 User s Guide VA

powerware 5105 User s Guide VA powerware 5105 User s Guide 450-1500 VA www.powerware.com Requesting a Declaration of Conformity The EC Declaration of Conformity is available upon request for products with a CE mark. For copies of the

More information

EATON 9130 UPS VA User's guide

EATON 9130 UPS VA User's guide ENGLISH EATON 9130 UPS 5000-6000 VA User's guide Copyright 2010 EATON All rights reserved. Service and support: Call your local service representative Class A EMC Statements Directives references This

More information

Powerware P64

Powerware P64 Powerware 91259 9910 - P64 High Performance High Reliability & Availability Flexible & Configurable Advanced Communications p64pres.ppt rev 4.16.04 1 P64 Features Double-conversion online High-power density

More information

HP UPS R/T3000 ERM. Overview. Precautions. Installation Instructions

HP UPS R/T3000 ERM. Overview. Precautions. Installation Instructions HP UPS R/T3000 ERM Installation Instructions Overview The ERM consists of two battery packs in a 2U chassis. The ERM connects directly to a UPS R/T3000 or to another ERM. Up to two ERM units can be connected.

More information

HP UPS R5500 User Guide

HP UPS R5500 User Guide HP UPS R5500 User Guide Part Number 351643-004A September 2007 (Fourth Edition) Copyright 2003, 2007 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without

More information

EATON Transformer Module

EATON Transformer Module www.eaton.com EATON Module Quick Start Standard Features When used with standard system, EATON Module provides isolated and Step-down 0/08/0 V AC outputs. Multiple Output receptacles: 0/08/0 V AC. 86-86000-0

More information

HP R/T3000 G2 UPS User Guide

HP R/T3000 G2 UPS User Guide HP R/T3000 G2 UPS User Guide Abstract This document includes installation, configuration, and operation information for the HP R/T3000 G2 UPS. This document is for the person who installs and maintains

More information

9910-UPS Rack Chart Updated Oct 05

9910-UPS Rack Chart Updated Oct 05 All devices and UPS in One rack? es One to Two* or Two or Four** 9188-7188 PDUs? es es If LPAR s or Web/SNMP connectivity (interface) required, select FC 934 If no LPAR s ensure p5 has #573 for serial

More information

Rack Installation Instructions

Rack Installation Instructions Rack Installation Instructions For System Storage EXP2512 and EXP2524 Express Storage Enclosures Use the instructions in this document to install an IBM System Storage EXP2512 Express Storage Enclosure

More information

Powerware 3105 UPS User s manual

Powerware 3105 UPS User s manual Powerware 3105 UPS 2005 Eaton Corporation All Rights Reserved The contents of this manual are the copyright of the publisher and may not be reproduced (even extracts) unless permission granted. Every care

More information

Powerware 3105 UPS User s manual

Powerware 3105 UPS User s manual Powerware 3105 UPS 2005 Eaton Corporation All Rights Reserved The contents of this manual are the copyright of the publisher and may not be reproduced (even extracts) unless permission granted. Every care

More information

IBM 9910 Uninterruptible Power Systems safeguard your equipment and data from power problems

IBM 9910 Uninterruptible Power Systems safeguard your equipment and data from power problems IBM United States Announcement 108-068, dated January 29, 2008 IBM 9910 Uninterruptible Power Systems safeguard your equipment and data from power problems Key prerequisites...2 Description...2 Publications...

More information

N3240 Installation and Setup Instructions

N3240 Installation and Setup Instructions IBM System Storage N3240 Installation and Setup Instructions Covering the N3240 model GA32-2203-01 Notices Mail comments to: IBM Corporation Attention Department GZW 9000 South Rita Road Tucson, AZ 85744-0001

More information

Powerware 9910-P11 and 9910-P16

Powerware 9910-P11 and 9910-P16 Powerware 9910-P11 and 9910-P16 High Performance High Reliability & Availability Flexible & Configurable Advanced Communications 2002 Eaton Corporation. All rights reserved. P11 and P16 Features Fourth-Generation

More information

Model 2380 Rack-Mount Kit

Model 2380 Rack-Mount Kit Keithley Instruments 28775 Aurora Road Cleveland, Ohio 44139 1-800-935-5595 http://www.tek.com/keithley Model 2380 Rack-Mount Kit Installation Instructions Introduction The Model 2380 Fixed Rack-Mount

More information

System Storage EXP3000 Rack Installation Instructions

System Storage EXP3000 Rack Installation Instructions System Storage EXP3000 Rack Installation Instructions Review the documentation that comes with your rack cabinet for safety and cabling information. When you install the IBM System Storage EXP3000 in a

More information

4-Post and Universal Telco Frame (UTF) Rack Mount Kit Installation Instructions

4-Post and Universal Telco Frame (UTF) Rack Mount Kit Installation Instructions 4-Post and Universal Telco Frame (UTF) Rack Mount Kit Installation Instructions Review the documentation that comes with your rack cabinet for safety and cabling information. Before installing your server

More information

UPS R3000 XR Maintenance and Service Guide

UPS R3000 XR Maintenance and Service Guide UPS R3000 XR Maintenance and Service Guide First Edition (September 2000) Part Number 221891-001 Spare Part Number 223932-001 Compaq Computer Corporation Notice 2000 Compaq Computer Corporation COMPAQ,

More information

Installation Job Aid for VSP 4850GTS

Installation Job Aid for VSP 4850GTS Installation Job Aid for VSP 4850GTS Notices Release 6.1.0.0 NN46251-308 Issue 02.01 November 2017 Notice paragraphs alert you about issues that require your attention. The following paragraphs describe

More information

Rack Installation Instructions

Rack Installation Instructions Rack Installation Instructions Review the documentation that comes with your rack cabinet for safety and cabling information. When installing your server in a rack cabinet, consider the following: v Two

More information

Model 2380 Rack-Mount Kit

Model 2380 Rack-Mount Kit Keithley Instruments 28775 Aurora Road Cleveland, Ohio 44139 1-800-935-5595 http://www.tek.com/keithley Model 2380 Rack-Mount Kit Installation Instructions Introduction The Model 2380 Fixed Rack-Mount

More information

Installation Job Aid for VSP 4450GTX-HT- PWR+

Installation Job Aid for VSP 4450GTX-HT- PWR+ Installation Job Aid for VSP 4450GTX-HT- PWR+ Notices Release 6.1.0.0 NN46251-305 Issue 02.01 November 2017 Notice paragraphs alert you about issues that require your attention. The following paragraphs

More information

IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS

IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS IMPORTANT SAFETY INSTRUCTIONS IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS WARNING (SAVE THESE INSTRUCTIONS): This manual contains important instructions that should be followed during installation

More information

N3150 Installation and Setup Instructions

N3150 Installation and Setup Instructions IBM System Storage N350 Installation and Setup Instructions Covering the N350 model GC27-426-0 Notices Mail comments to: IBM Corporation Attention Department GZW 9000 South Rita Road Tucson, AZ 85744-000

More information

4170 POS System Installation Guide

4170 POS System Installation Guide 4170 POS System 4170 Installation Guide Thank you for selecting UTC RETAIL s innovative Model 4170 Point of Sale solution! This Installation Guide will help you efficiently install the 4170 POS. The document

More information

Allworx 24x Service and Troubleshooting Guide

Allworx 24x Service and Troubleshooting Guide Allworx 24x Service and Troubleshooting Guide -PAGE INTENTIALLY LEFT BLANK- Table of Contents 1 Safety Instructions...1 1.1 Electrical...1 1.2 Electrostatic Discharge...1 2 Chassis Views...2 3 Exterior

More information

N3220 Installation and Setup Instructions

N3220 Installation and Setup Instructions IBM System Storage N3220 Installation and Setup Instructions Covering the N3220 model GA32-2202-01 Notices Mail comments to: IBM Corporation Attention Department GZW 9000 South Rita Road Tucson, AZ 85744-0001

More information

IBM. Rack Installation Instructions

IBM. Rack Installation Instructions IBM Rack Installation Instructions Review the documentation that comes with your rack cabinet for safety and cabling information. When installing your server in a rack cabinet, consider the following:

More information

Installation Job Aid for Ethernet Routing Switch 5900 Series

Installation Job Aid for Ethernet Routing Switch 5900 Series Installation Job Aid for Ethernet Routing Switch 5900 Series Notices NN47211-301 Issue 05.01 November 2017 Notice paragraphs alert you about issues that require your attention. The following paragraphs

More information

Series 3700 Screw Terminal Assemblies Installation Instructions

Series 3700 Screw Terminal Assemblies Installation Instructions Keithley Instruments, Inc. 28775 Aurora Road Cleveland, Ohio 44139 1-888-KEITHLEY www.keithley.com Series 3700 Screw Terminal Assemblies Installation Instructions Introduction This document contains handling

More information

EX RT 5/7/11 Systems Installation and User Manual

EX RT 5/7/11 Systems Installation and User Manual www.eaton.com EX RT 5/7/11 Systems Installation and User Manual EX RT 5/7/11 Systems Installation and User Manual Revision History EX RT 5/7/11 Systems Installation and User Manual, 86-86000-00 Revision:

More information

IBM 9910 Uninterruptible Power Systems safeguard your equipment and data from power problems

IBM 9910 Uninterruptible Power Systems safeguard your equipment and data from power problems IBM Latin America Hardware Announcement LG10-0100, dated May 18, 2010 IBM 9910 Uninterruptible Power Systems safeguard your equipment and data from power problems Table of contents 1 Overview 2 Product

More information

eserver Integration

eserver Integration 9125 - eserver TOPICS Preparation Startup Optional Features Help/Resources 9125Install - iseries Dec, 2000 Page 1 Step 1 - Remove UPS equipment from Cartons UPS must be placed near the installation site

More information

Installation and Maintenance

Installation and Maintenance CHAPTER 4 Installation and Maintenance Revised: April 19, 2010, Introduction This chapter explains how to install a SCE 1000 platform in a rack or in a general tabletop or workbench installation. Additionally,

More information

Junos WebApp Secure 5.0 Hardware Guide

Junos WebApp Secure 5.0 Hardware Guide Junos WebApp Secure 5.0 Hardware Guide Junos WebApp Secure 5.0 Hardware Guide This document contains a specification for the MWS1000 hardware appliance, as well as instructions for installation into a

More information

PowerNet RM SERIES 1500VA & 2200VA Line-interactive UPS USER MANUAL

PowerNet RM SERIES 1500VA & 2200VA Line-interactive UPS USER MANUAL PowerNet RM SERIES 1500VA & 2200VA Line-interactive UPS USER MANUAL Maruson Technology Corporation P.O. Box 1986, Walnut, CA 91788 USA Toll Free: 1-888-MARUSON Website: www.marusonusa.com E-Mail: Info@MarusonUSA.com

More information

TRC-190 User s Manual

TRC-190 User s Manual User s Manual Edition 3.2, May 2017 www.moxa.com/product 2017 Moxa Inc. All rights reserved. User s Manual The software described in this manual is furnished under a license agreement and may be used only

More information

TRC-190 User s Manual

TRC-190 User s Manual First Edition, November 2008 www.moxa.com/product 2008 Moxa Inc. All rights reserved. Reproduction without permission is prohibited. The software described in this manual is furnished under a license agreement

More information

E1135C PDU and Pod Upgrade Procedure

E1135C PDU and Pod Upgrade Procedure E4030-90010 Rev. B 12/2003 In this Document... Tools Needed, 2 Contents of the Upgrade Kits, 2 Installation Procedures, 4 Verifying the Power Option of the New PDU, 4 Removing the PDU from the Support

More information

OFFICE UPS MULTI-DEVICE PROTECTION UPS 500S/600S/750S

OFFICE UPS MULTI-DEVICE PROTECTION UPS 500S/600S/750S OFFICE UPS MULTI-DEVICE PROTECTION UPS 500S/600S/750S USER S MANUAL 1.Safety instructions Thank you for selecting this uninterrupted power source. It provides you with better protection for connected equipment.

More information

IBM 9910 Uninterruptible Power Systems safeguard your equipment and data from power problems

IBM 9910 Uninterruptible Power Systems safeguard your equipment and data from power problems IBM United States Hardware Announcement 110-077, dated May 18, 2010 IBM 9910 Uninterruptible Power Systems safeguard your equipment and data from power problems Table of contents 1 Overview 2 Product number

More information

Replacing the Power Supply

Replacing the Power Supply APPENDIX B This appendix includes information on how to replace the power supply for the Cisco AS550XM universal gateway and contains the following sections: Safety Recommendations, page B-1 Required Tools

More information

Installation Note for the Cisco ME 3800X and ME 3600X Switch Power Supply and Fan Modules

Installation Note for the Cisco ME 3800X and ME 3600X Switch Power Supply and Fan Modules Installation Note for the Cisco ME 3800X and ME 3600X Switch Power Supply and Fan Modules This document provides the installation and removal instructions for the AC and DC input power supply and fan modules

More information

TraceTek Leak Detection Master Module Installation Instructions TOOLS REQUIRED STORAGE

TraceTek Leak Detection Master Module Installation Instructions TOOLS REQUIRED STORAGE TTDM-128 TraceTek Leak Detection Master Module Installation Instructions TRACETEK APPROVALS AND CERTIFICATIONS TYPE NM General Signaling Equipment 76LJ GENERAL INFORMATION Please read these instructions

More information

The power behind competitiveness. Delta Infrasuite Power Management. Power Distribution Unit. User Manual.

The power behind competitiveness. Delta Infrasuite Power Management. Power Distribution Unit. User Manual. The power behind competitiveness Delta Infrasuite Power Management Power Distribution Unit User Manual www.deltapowersolutions.com Save This Manual This manual contains important instructions and warnings

More information

EATON 5S 850/1200/1600

EATON 5S 850/1200/1600 www.eaton.com EATON 5S 850/1200/1600 Installation and user manual Packaging EATON 5S 1 2 3 5 Caution! l Before installing the Eaton 5S, read the booklet 3 containing the safety instructions to be respected.

More information

Installation and Configuration Guide

Installation and Configuration Guide Installation and Configuration Guide Trademark Notices Comtrol, NS-Link, and DeviceMaster are trademarks of Comtrol Corporation. Microsoft and Windows are registered trademarks of Microsoft Corporation.

More information

Serial ATA Hot Swap Drive Cage Upgrade Kit for: Intel Server Chassis SC5200 Intel Server Chassis SC5250-E

Serial ATA Hot Swap Drive Cage Upgrade Kit for: Intel Server Chassis SC5200 Intel Server Chassis SC5250-E Serial ATA Hot Swap Drive Cage Upgrade Kit for: Intel Server Chassis SC5200 Intel Server Chassis SC5250-E A Guide for Technically Qualified Assemblers of Intel Identified Subassemblies/Products Order Number:

More information

Model: VA/230W UPS Backup System

Model: VA/230W UPS Backup System IMPORTANT SAFETY INSTRUCTIONS (SAVE THESE INSTRUCTIONS) This manual contains important safety instructions. Please read and follow all instructions carefully during installation and operation of unit.

More information

EXN4000 Storage Expansion Unit Installation and Setup Instructions

EXN4000 Storage Expansion Unit Installation and Setup Instructions IBM System Storage EXN4000 Storage Expansion Unit Installation and Setup Instructions GC27-2079-02 IBM System Storage EXN4000 Storage Expansion Unit Installation and Setup Instructions GC27-2079-02 Notices

More information

IBM 9910 UPSs for IBM iseries and pseries safeguard your equipment and data from power problems

IBM 9910 UPSs for IBM iseries and pseries safeguard your equipment and data from power problems Hardware Announcement April 20, 2004 IBM 9910 UPSs for IBM iseries and pseries safeguard your equipment and data from power problems Overview To meet the changing power protection needs of IBM servers,

More information

Power Supply and Fan Module Installation

Power Supply and Fan Module Installation 3 CHAPTER This chapter describes how to remove and install a new or replacement power supply or fan module in a Catalyst 3750-E or Catalyst 3560-E switch. See these sections: Installation Overview, page

More information

Cisco CRS 3-Phase AC Power Distribution Unit Installation Guide 2. Cisco CRS 3-Phase AC Power Distribution Unit 2

Cisco CRS 3-Phase AC Power Distribution Unit Installation Guide 2. Cisco CRS 3-Phase AC Power Distribution Unit 2 Cisco CRS 3-Phase AC Power Distribution Unit Installation Guide Cisco CRS 3-Phase AC Power Distribution Unit Installation Guide 2 Cisco CRS 3-Phase AC Power Distribution Unit 2 Revised: November 18, 2016,

More information

Quick Start. This document describes how to install the Juniper Networks PTX5000 Packet Transport

Quick Start. This document describes how to install the Juniper Networks PTX5000 Packet Transport PTX5000 Packet Transport Router Quick Start September 2017 Part Number: 530-066788 Revision 01 This document describes how to install the Juniper Networks PTX5000 Packet Transport Router. Contents Quick

More information

Installation Job Aid for Ethernet Routing Switch 3600 Series

Installation Job Aid for Ethernet Routing Switch 3600 Series Installation Job Aid for Ethernet Routing Switch 3600 Series Notices NN47213-303 Issue 03.01 November 2017 Notice paragraphs alert you about issues that require your attention. Following are descriptions

More information

UPS USER S GUIDE kva, 50 and 60 Hz.

UPS USER S GUIDE kva, 50 and 60 Hz. 9170 + 3 18 kva, 50 and 60 Hz UPS USER S GUIDE www.powerware.com Requesting a Declaration of Conformity Units that are labeled with a CE mark comply with the following harmonized standards and EU directives:

More information

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description Vision OPLC V350-35-R34/V350-J-R34 Installation Guide The Unitronics V350-35-R34/V350-J-R34 offers the following onboard I/Os: 22 Digital Inputs, configurable via wiring to include 2 Analog and 3 HSC/Shaft-encoder

More information

Configuration Questions:

Configuration Questions: Configuration Questions: 1 What equipment will be protected? Calculate using Table 1 What do I want the UPS to do? Shutdown server(s) interface? Provide extended battery (autonomy) runtime? 3 Where do

More information

Installation and Operation Back-UPS BR1000G-IN / BR1500G-IN

Installation and Operation Back-UPS BR1000G-IN / BR1500G-IN Installation and Operation Back-UPS BR1000G-IN / BR1500G-IN Important Safety Information Read the instructions carefully to become familiar with the equipment before trying to install, operate, service

More information

Installing the Cisco AS5400XM Universal Gateway

Installing the Cisco AS5400XM Universal Gateway CHAPTER 3 Installing the Cisco AS5400XM Universal Gateway This chapter guides you through the installation of the Cisco AS5400XM universal gateway and includes the following sections: Setting Up the Chassis,

More information

Perle MCR200 Installation Guide

Perle MCR200 Installation Guide Perle MCR200 Installation Guide P/N 5500322-10 Introduction The Perle MCR200 Chassis is a 2 slot chassis able to accommodate up to 2 Perle Media Converter modules or 1 Media Converter Module and an MCR-MGT

More information

System Storage DS3950 Quick Start Guide

System Storage DS3950 Quick Start Guide System Storage DS3950 Quick Start Guide This Quick Start Guide describes the basic procedure for installing, cabling, and configuring the IBM System Storage DS3950 storage subsystem (Machine Types 1814-94H

More information

This 4200-RM Rack Mount Kit is for installation in 4200-CAB series cabinets only.

This 4200-RM Rack Mount Kit is for installation in 4200-CAB series cabinets only. Keithley Instruments, Inc. 28775 Aurora Road Cleveland, Ohio 44139 (440) 248-0400 Fax: (440) 248-6168 www.keithley.com Model 4200-RM Rack Mount Kit Packing List Introduction NOTE This 4200-RM Rack Mount

More information

1000VA/1500VA/2000VA/3000VA

1000VA/1500VA/2000VA/3000VA USER MANUAL Line Interactive UPS 1000VA/1500VA/2000VA/3000VA Uninterruptible Power Supply System IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS This manual contains important instructions for 1000VA/1500VA/2000VA/3000VA

More information

POWER AVAILABILITY 2U POD USER MANUAL. Power Output Distribution 120 Volt

POWER AVAILABILITY 2U POD USER MANUAL. Power Output Distribution 120 Volt POWER AVAILABILITY 2U POD USER MANUAL Power Output Distribution 120 Volt TABLE OF CONTENTS IMPORTANT SAFETY INSTRUCTIONS.......................................... 1 GLOSSARY OF SYMBOLS..................................................

More information

Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual

Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual Omnitron Systems Technology, Inc. 1 iconverter 19-Module Managed Power Chassis User s Manual 27 Mauchly, #201, Irvine, CA 92618 Phone: (949) 250-6510; Fax: (949) 250-6514 2 Omnitron Systems Technology,

More information

Liebert MicroPOD 230V

Liebert MicroPOD 230V AC Power For Business-Critical Continuity Liebert MicroPOD 230V User Manual TABLE OF CONTENTS 1.0 IMPORTANT SAFETY INSTRUCTIONS...........................................1 2.0 GLOSSARY OF SYMBOLS..................................................2

More information

User Manual Back-UPS BE650MC

User Manual Back-UPS BE650MC User Manual Back-UPS BE650MC Inventory Back-UPS ES 650 bu075b This unit is intended for indoor use only. Do not operate this unit in direct sunlight, in contact with fluids, or where there is excessive

More information

Evolution 650/650 Rack 1U 850/850 Rack 1U 1150/1150 Rack 1U 1550/1550 Rack 1U Installation and user manual Pulsar Series

Evolution 650/650 Rack 1U 850/850 Rack 1U 1150/1150 Rack 1U 1550/1550 Rack 1U Installation and user manual Pulsar Series www.eaton.com _ Evolution 650/650 Rack 1U 850/850 Rack 1U 1150/1150 Rack 1U 1550/1550 Rack 1U Installation and user manual Pulsar Series 34008235EN/AC - Page 2 Introduction Thank you for selecting an EATON

More information

Powerware Software Connectivity Service. > Powerware Software Suite ensures data integrity; free updates on

Powerware Software Connectivity Service. > Powerware Software Suite ensures data integrity; free updates on Powerware 9120 Features True double conversion online technology give you protection from all nine power problems Simple installation and operation Intuitive LCD screen provides realtime updates of UPS

More information

Instruction Manual. Electrical Management System (EMS) EMS-HW30C & EMS-HW50C

Instruction Manual. Electrical Management System (EMS) EMS-HW30C & EMS-HW50C Instruction Manual Electrical Management System (EMS) EMS-HW30C & EMS-HW50C EMS-HW50C EMS-HW30C! CAUTION These instructions are intended to provide assistance with the installation of this product, and

More information

Prestige - eserver Integration

Prestige - eserver Integration Prestige - eserver TOPICS Preparation Startup Optional Features Help/Resources PrestInstall - eserver rev Apr 01 Page 1 Step 1 - Remove UPS equipment from Cartons UPS must be placed near the installation

More information

Configuration Questions:

Configuration Questions: Configuration Questions: 1 What equipment will be protected? Calculate using Table 1 What do I want the UPS to do? Shutdown server(s) interface? Provide extended battery (autonomy) runtime? 3 Where do

More information

Active UTP Transceiver Hub with Integral Isolated Camera Power

Active UTP Transceiver Hub with Integral Isolated Camera Power Active UTP Transceiver Hub with Integral Isolated Installation Guide HubWayEX16SP - UL Listed sixteen (16) Channel Active UTP Transceiver Hub with Integral Isolated Rev. 011810 More than just power. TM

More information

Dell Online Rack UPS 5600W. User's Guide. Dell 5600R OL HV-US, Dell 5600R OL HV K812N. w w w. d e l l. c o m s u p p o r t. d e l l.

Dell Online Rack UPS 5600W. User's Guide. Dell 5600R OL HV-US, Dell 5600R OL HV K812N. w w w. d e l l. c o m s u p p o r t. d e l l. Dell Online Rack UPS 5600W User's Guide Dell 5600R OL HV-US, Dell 5600R OL HV K812N w w w. d e l l. c o m s u p p o r t. d e l l. c o m Notes and Warnings NOTE: A NOTE indicates important information that

More information

Vision OPLC V TR6/V350-J-TR6

Vision OPLC V TR6/V350-J-TR6 Vision OPLC V350-35-TR6/V350-J-TR6 Installation Guide The Unitronics V350-35-TR6/V350-J-TR6 offers the following onboard I/Os: 8 Digital Inputs, configurable via wiring to include 2 Analog (current/voltage)

More information

Rack Installation Instructions

Rack Installation Instructions Rack Installation Instructions Review the documentation that comes with your rack cabinet for safety and cabling information. Before installing your server in a rack cabinet, review the following guidelines:

More information

Product Snapshot. The Powerware Uninterruptible Power System. Product Focus

Product Snapshot. The Powerware Uninterruptible Power System. Product Focus Powerware 9120 Uninterruptible Power System Product Focus Product Snapshot Power Rating: 700-3000VA Voltage: 120 and 230 Vac Frequency: 50/60 Hz (auto-sensing) Configuration: tower Features True double-conversion

More information

Powerware P60/61

Powerware P60/61 ware 51405 9910 P60/61 Runtime and Rack Connections P60 & P61 Runtime and Rack Connections v5.ppt Battery Runtime Matrix Battery Runtime (in minutes)* Standard (Std) Watts Internal Batteries 1 EBM 2 EBMs

More information

Installing and Configuring Rialto Analytic Appliances

Installing and Configuring Rialto Analytic Appliances Installing and Configuring Rialto Analytic Appliances Important Safety Information This manual provides installation and operation information and precautions for the use of this camera. Incorrect installation

More information

Model HM-535 Power Supply Installation and Service Instructions

Model HM-535 Power Supply Installation and Service Instructions Model HM-535 Power Supply Installation and Service Instructions 430-535 0104 2004 Heritage MedCall, Inc SENTRY INSTALLATION & SERVICE INSTRUCTIONS POWER SUPPLY UNIT Model HM-535 IMPORTANT SAFETY INSTRUCTIONS

More information

9910 P18. Advanced power protection for mission-critical System p, System x, Storage and Networking rack products and applications. P18.

9910 P18. Advanced power protection for mission-critical System p, System x, Storage and Networking rack products and applications. P18. 9910 P18 Advanced power protection for mission-critical System p, System x, Storage and Networking rack products and applications 2002 Eaton Corporation. All rights reserved. P18.ppt P18 snapshot High

More information

OPTICAL HEADEND PLATFORM OTOHP-CH 3RU CHASSIS OTOHP-PS POWER SUPPLY MODULE OTOHP-BP BLANK PANEL INSTRUCTION MANUAL

OPTICAL HEADEND PLATFORM OTOHP-CH 3RU CHASSIS OTOHP-PS POWER SUPPLY MODULE OTOHP-BP BLANK PANEL INSTRUCTION MANUAL OPTICAL HEADEND PLATFORM OTOHP-CH 3RU CHASSIS OTOHP-PS POWER SUPPLY MODULE OTOHP-BP BLANK PANEL INSTRUCTION MANUAL Phone: (209) 586-1022 (800) 545-1022 Fax: (209) 586-1026 OTOHP-CH Rev. X1 E-Mail: salessupport@olsontech.com

More information

Installation and user manual English Français Deutsch Italiano Español Nederlands Pulsar Series

Installation and user manual English Français Deutsch Italiano Español Nederlands Pulsar Series www.eaton.com Evolution S 1250 RT 2U S 1750 RT 2U 2000 RT 2U S 2500 RT 2U S 3000 RT 2U S 3000 RT 3U S EXB 1250/1750 RT 2U S EXB 2500/3000 RT 2U S EXB 2500/3000 RT 3U Installation and user manual English

More information

PS/IO Circuit Board Retrofit

PS/IO Circuit Board Retrofit S&C 6800 Series Automatic Switch Controls PS/IO Circuit Board Retrofit Table of Contents Section Page Introduction Qualified Persons.... 2 Read this Instruction Sheet.... 2 Retain this Instruction Sheet....

More information

INSTALLATION MANUAL SLI 50 INVERTER

INSTALLATION MANUAL SLI 50 INVERTER INSTALLATION MANUAL SLI 50 INVERTER www.unipowerco.com Manual No. SLI-50-48-3 2016 UNIPOWER LLC All Rights Reserved UNIPOWER LLC 3900 Coral Ridge Drive, Coral Springs, Florida 33065, USA sales@unipowerco.com

More information

PoE/FPR Kit for Auto-Sync Time Clock. The Auto-Sync Time Clock is a validated time system with a Web interface and auto discovery.

PoE/FPR Kit for Auto-Sync Time Clock. The Auto-Sync Time Clock is a validated time system with a Web interface and auto discovery. ASTCPOEK PoE/FPR Kit for Auto-Sync Time Clock The Auto-Sync Time Clock is a validated time system with a Web interface and auto discovery. The ASTCPOEK Kit provides Power over Ethernet with Full Power

More information

Product Snapshot. the Powerware Uninterruptible Power System. Double-conversion, online design offers superior reliability and protection

Product Snapshot. the Powerware Uninterruptible Power System. Double-conversion, online design offers superior reliability and protection Powerware 9125 Uninterruptible Power System Product Focus 700-6000 VA Powerware 9125 6000 VA Features Protects mission-critical applications from downtime, data loss and corruption, and process interruption

More information

GV3000/SE AC Drive ControlNet Network Communication Option Board M/N 2CN3000

GV3000/SE AC Drive ControlNet Network Communication Option Board M/N 2CN3000 GV3000/SE AC Drive ControlNet Network Communication Option Board M/N 2CN3000 Instruction Manual D2-3390-2 The information in this manual is subject to change without notice. Throughout this manual, the

More information

Model 2460-KIT. Screw Terminal Connector Kit. Description / September 2014 *P * 1

Model 2460-KIT. Screw Terminal Connector Kit. Description / September 2014 *P * 1 Keithley Instruments 28775 Aurora Road Cleveland, Ohio 44139 1-800-935-5595 http://www.keithley.com Model 2460-KIT Screw Terminal Connector Kit Description The Model 2460-KIT Screw Terminal Connector Kit

More information

Electrical Management System (EMS) EMS-HW30C & EMS-HW50C

Electrical Management System (EMS) EMS-HW30C & EMS-HW50C Electrical Management System (EMS) EMS-HW30C & EMS-HW50C Installation & Operating Guide for: Model EMS-HW30C Rated at 120V/30A and Model EMS-HW50C Rated at 240V/50A Surgio Says Lifetime Warranty on all

More information

Installing the IPS 4345 and IPS 4360

Installing the IPS 4345 and IPS 4360 CHAPTER 4 Installing the IPS 4345 and IPS 4360 Contents This chapter describes the Cisco IPS 4345 and the IPS 4360, and includes the following sections: Installation Notes and Caveats, page 4-1 Product

More information