BA/BS4S Temperature Sensor Installation & Operating Instructions
|
|
- Lee Richardson
- 6 years ago
- Views:
Transcription
1 Product Overview and Identification The BAPI-Stat 4 room temperature sensor features a large format LCD and slider setpoint adjustment. Additional options include button override and communication jack. The setpoint is available as a resistance or voltage output. The override is a momentary closure signal that can be configured in parallel with the sensor or setpoint, or as a separate momentary or latching contact output. A 3.5mm (1/8 ), RJ11 or RJ22 communication jack can also be mounted in the unit s base to provide direct access to the network. Fig 1. BAPI-Stat 4S with slider setpoint adjustment and optional and override button. Mounting JUNCTION BOX 1. Pull the wire through the wall and out of the junction box, leaving about six inches free. 2. Pull the wire through the hole in the base plate. 3. Secure the base to the box using the #6-32 x 1/2 inch mounting screw provided. 4. Terminate the unit according to the guidelines in the Termination section. 5. Attach Cover by latching it to the top of the base, rotating the cover down and snapping it into place. 6. Secure the cover by backing out the lock-down screws using a 1/16 Allen wrench until they are flush with the bottom of the cover. DRYWALL MOUNTING 1. Place the base plate against the wall where you want to mount the sensor. 2. Using a pencil, mark out the two mounting holes and the area where the wires will come through the wall. 3. Drill two 3/16 holes in the center of each marked mounting hole. Insert a drywall anchor into each hole. Fig. 2: Mounting hardware is provided for 4. Drill one 1/2 hole in the middle of the marked wiring area. both junction box and drywall installation (junction box installation shown). 5. Pull the wire through the wall and out of the 1/2 hole, leaving about six inches free. 6. Pull the wire through the hole in the base plate. 7. Secure the base to the drywall anchors using the #6 x 1 inch mounting screws provided. 8. Terminate the unit according to the guidelines in the Termination section. 9. Attach Cover by latching it to the top of the base, rotating the cover down and snapping it into place. 10. Secure the cover by backing out the lock-down screws using a 1/16 Allen wrench until they are flush with the bottom of the cover. NOTE: In a wall-mount application, the mixing of room air and air from within the wall cavity can lead to erroneous readings, condensation, and premature failure of the sensor. To prevent this condition, plug the conduit hole with insulation in the junction box. 1 of 6
2 Termination BAPI recommends using twisted pair of at least 22AWG and sealant filled connectors for all wire connections. Larger gauge wire may be required for long runs. All wiring must comply with the National Electric Code (NEC) and local codes. Do NOT run this device s wiring in the same conduit as AC power wiring. BAPI s tests show that fluctuating and inaccurate signal levels are possible when AC power wiring is present in the same conduit as the signal lines. Fig. 3 BAPI-Stat 4 Circuit Board Terminal GND Description Power Supply Ground (Common to the controller) V+ Power Supply Hot (See specifications for voltage details) FAN EXT OVR SEN1 & SEN2 Not Used BAPI-Man Occ/Un-Occ indicator Input. Ground terminal to fill in the BAPI-Man icon for Occupied. Sensor output per order (resistive). No polarity. *If the unit is a common ground configuration ( CG), see Grounding Note below. SET1 & SET2 A) Setpoint output per order (resistive). No polarity. *If the unit is a common ground configuration ( CG), see Grounding Note below. OVR1 & OVR2 B) Setpoint output per order (voltage). SET1 is +, SET2 is -. *If the unit is a common ground configuration ( CG), see Grounding Note below. Override output (Dry contact) The contact can be ordered as a momentary shunt across the sensor (-N) or as a momentary shunt across the setpoint (-P) or as a separate momentary contact (-J) or as a separate latching contact (-L#). *If the unit is a common ground configuration ( CG), see Grounding Note below. RSEN1 & RSEN2 Remote sensor option (-ES). No polarity. *If the unit is a common ground configuration ( CG), see Grounding Note below. A 10K-2 thermistor sensor must be ordered separately and the temperature value is displayed on the LCD. Note: If a temperature reading is needed at the controller, then a second sensor must be ordered and wired independently. *Grounding Note: Common Ground (-CG) or Differential Ground (-DF) configurations are selected per order. The Differential Ground configuration (-DF) indicates that SEN2, SET2, OVR2 and RSEN2 must all be wired separately (No internal common connection). The Common Ground configuration (-CG) indicates that SEN2, SET2, OVR2 and RSEN2 are connected to GND internally (All internally common). This is true of all Common Ground units except when ordered with the Override as a Latching Switch option (-L#). In this case, OVR2 is isolated and not internally connected to SEN2, SET2 and RSEN2. Optional Communication Jack Wiring Fig. 5: C35L Comm Jack Note: Male jack shown for clarity C11L/ C22L C35L C11L/C22L Wiring Comm Jack Pin Wire Color Fig. 4: Back Plate Fig. 6: C11L/C22L Comm Jack Green 2 of 6
3 Optional Test and Balance Switch (-TB) Optional Test and Balance Switch Low: Will set the sensor value low Norm: Thermistor/RTD will operate normally High: Will set the sensor value high Consult Factory for Additional Details Sensor Type Low Temp (40º F) High Temp (105º F) Resistance Value Resistance Value 1000Ω RTD 1.02KΩ (41.2º F) 1.15KΩ (101.5º F) 3000Ω Thermistor 7.87KΩ (39.8º F) 1.5KΩ (106.8º F) 10K-2 Thermistor 30.1KΩ (34.9º F) 4.75Ω (109.1º F) 10K-3 Thermistor 26.7KΩ (35.9º F) 5.11KΩ (108.4º F) 10K-3(11K) Thermistor 7.32KΩ (43.7º F) 3.65Ω (105.2º F) Display, Setpoint and Override Descriptions BAPI-Stat 4S sensor comes with a display and slider setpoint adjustment. An optional side override button is also available. Figure 7 shows a unit with the override button. NUMERICAL DISPLAY: The default display shows current temperature. When the slider setpoint is moved enough to change the setpoint by 0.5 degrees, the setpoint will be displayed for 3 to 4 seconds. The unit can also be set up to display setpoint only or for setpoint lockout. See Optional Technicians Adjustments on page 4 (Mode Menu P2). BAPI-MAN ICON: The BAPI-Man Icon shows the status of the room Solid for Occupied, Hollow for Unoccupied (Fig. 10). Note: The unit must receive a confirmation (ground) signal on the EXT OVR terminal for the BAPI-Man to remain visible on the screen. Pressing the Override button will light the BAPI-Man icon; however, if no confirmation signal is received, then the BAPI-Man will go blank (disappear) after 5 seconds. BAPI-Man Icon (See Figure 8) Fig 7. BAPI-Stat 4S with Display, Slider Setpoint, and Override Button Upon receiving a first confirmation (ground) signal on the EXT OVR terminal, the BAPI-Man will show occupied (Solid). The BAPI-Man will then show unoccupied (Hollow) whenever the confirmation signal is removed and occupied when the signal is returned. The only way to blank the BAPI-Man from the display at this point is to cycle power. SETPOINT: When the slide setpoint is moved enough to change the setpoint by 0.5 degrees, the setpoint will be displayed. Slide the setpoint up or down to the desired setpoint. OVERRIDE: When the override button is pressed, the BAPI-Man will be displayed as Solid for 3-5 seconds and the override output will shunt or short for 3 seconds depending on the override option selected. -N Option = Momentary Temperature Sensor Shunt to < 15Ω -P Option = Momentary Setpoint Shunt to <15Ω -J Option = Momentary Override as a Separate Shorting Contact Output on OVR1 & OVR2 -L# Option = Override as a Latching Switch (See Latching Override Operation on pg. 5.) Solid equals Occupied Engineering Units Override Button Temperature Display in.5 or.1 Increments Setpoint Slider Hollow equals Unoccupied Fig. 8: BAPI-Man Icon If the occupied input (EXT OVR) terminal is grounded, then the BAPI-Man will stay filled in, indicating an occupied state. If the input is open, then the BAPI-Man will revert to hollow, indicating unoccupied (or the icon will disappear completely if there has never been a ground on the EXT OVR terminal). 3 of 6
4 Optional Technician Adjustments (The sensor set-up is factory set per your order. Set-up adjustments are not required) The unit is shipped ready to install per the order and does not requires any special setup or programming. The following Setup or Program Menu Changes are available if the installer decides to change the factory settings. ENTERING PROGRAM MODE AND MAKING CHANGES: 1. Remove cover and install the shunt jumper across the J16 pins (see Fig. 9). 2. Use the Up and Down Switches on the back of the circuit board (Fig. 10) to advance to the parameter to adjust. (Moves up or down from page to page or from setting to setting.) 3. Use the Override button (or Enter Switch on the back of the circuit board if the unit is Fig. 9: J16 Program Jumper ordered without an Override, see Fig. 10) to select the menu parameter. This selects the currently displayed menu or selects the new parameter and stores it into memory. You can adjust and quit (remove J16) any time during this procedure. Be sure to press the Override button or Enter switch to store your selection or it will not be saved. MODE MENUS: The set-up mode consists of menu pages P0 through P4 for configuring the sensor. The following are the adjustments that can be done with the program jumper J16 installed. P0 - Temperature offset: (Changes the display only. An independent reference is recommended.) Use the Up and Down Switchs to adjust the temperature ±3º in.5º (F or C) increments. Push the Override button or Enter switch to store the offset value. P1 - ºF or ºC Display: Use the Up and Down Switches to select F or C display. Push the Override button or Enter switch to store the value. P2 - Display Options or Setpoint Lockout Options: SP = SPL = Setpoint Enabled (This is the default configuration). The unit displays the room temp except when the Setpoint is being adjusted by the Up and Down Pushbuttons. Setpoint Lockout. Disables the setpoint display but the setpoint slider operates normally. SDO = Setpoint Display Only. The unit only displays the setpoint, not the room temperature. SDN = Setpoint Display Disabled. Operates the same as the SPL mode described above. P3 - Latching Override Option: This selection only can be adjusted if you have ordered the Latching Override Option (-L#). This has selections 1-10 shown in Fig. 11 and described in the Latching Override Operation section on page 5. P4 - Temperature Increments - ºF or ºC: This selection adjusts the display resolution increments as.1º or.5º (in either F or C Mode) 0.1 = This will display all temperatures in 0.1 degree increments. 0.5 = This will display all temperatures in 0.5 degree increments. Non-Latching Override Operation Jumper Off - Run Mode Fig. 10: Setup Switch locations on the circuit board. Note: The Enter switch is only present if the unit is ordered without Override. Jumper On - Program Mode When the Override button is pressed, the BAPI-Man (Fig. 8) will be displayed as Solid for 3-5 seconds and the override output will shunt or short for 3 seconds depending on the override option selected. The various options are described below. -N Option = Momentary Temperature Sensor Shunt to < 15Ω -P Option = Momentary Setpoint Shunt to <15Ω -J Option = Momentary Override as a Separate Shorting Contact Output on OVR1 & OVR2 -L# Option = Override as a Latching Switch (See Latching Override Operation on pg. 5.) BAPI-MAN ICON: The BAPI-Man Icon shows the status of the room Solid for Occupied, Hollow for Unoccupied (Fig. 8). The unit must receive a confirmation (ground) signal on the EXT OVR terminal for the BAPI-Man to remain visible on the screen. Pressing the Override button will light the BAPI-Man icon; however, if no confirmation signal is received, then the BAPI-Man will go blank (disappear) after 5 seconds. Upon receiving a first confirmation (ground) signal on the EXT OVR terminal, the BAPI-Man will show occupied (Solid). The BAPI-Man will then show unoccupied (Hollow) whenever the confirmation signal is removed and occupied when the signal is returned. The only way to blank the BAPI-Man from the display at this point is to cycle power. Up Down Enter 4 of 6
5 Latching Override Operation In the Override as Latching Display Option (-L#), pressing the Override button closes the override relay contacts (Terminals OVR1 & OVR2). They will remain closed until the Override button is pressed again, then they will open and remain open until the Override button is pressed again. See Fig. 12 below for examples of Override as a Latching Switch circuits. Ten display options (Fig. 11) are available to indicate when the latching relay is open and when the latching relay is closed. BAPI-Man Icon On Options 2, 4, 6, 8 & 10, the BAPI-Man Icon is disabled and will not show on the display, even when the Override button is pushed. On Options 1, 3, 5 & 7, the BAPI-Man Icon is filled or solid for 3 to 5 seconds after the Override button is pushed, but it will only remain solid or filled when there is a ground signal to the EXT OVR terminal of the unit. For Option 9, the BAPI-Man Icon stays filled or solid when the relay is closed and hollow when the relay is open. For Option 10, the BAPI-Man Icon is disabled but the ON or OFF Dot on the display is controlled by the EXT OVR terminal. When there is a ground signal at the EXT OVR terminal, the ON dot is lit. Otherwise the OFF and hollow dot are lit. Note: The Override Terminals OVR1 and OVR2 are NOT latching in Option 10. These terminals close MOMENTARILY in this option. Latching Switch with External Load ANALOG OR DIGITAL INPUT OF CONTROLLER Latching Switch as Direct Controller Input Circuit Fig. 12: Latching Switch Wiring Diagrams In the Override as Latching Switch configuration, terminals OVR1 & OVR2 act as a latching switch with a maximum capacity of 24 VAC/VDC at 800 ma resistive. Pressing the Override button latches or unlatches the OVR1 & OVR2 terminals. These diagrams show how to wire the latching switch with an External Load and as a Direct Controller Input Fig. 11: Latching Switch Display Options The 10 Override as a Latching Switch display options are shown above for when the relay is open and when the relay is closed. Note 2: On Options 1, 3, 5 & 7, the BAPI-Man Icon is filled or solid for 3 to 5 seconds after the Override button is pushed, but it will only remain solid or filled when there is a ground signal to the EXT OVR terminal of the unit. 5 of 6
6 General Diagnostics POSSIBLE PROBLEM: Temperature reading is incorrect POSSIBLE SOLUTIONS: - Determine that the input is set up correctly in the controller s and building automation software. - Check wiring for proper termination - Check for corrosion at either the controller or the sensor. Clean off the corrosion, re-strip the interconnecting wire and reapply the connection. In extreme cases, replace the controller, interconnecting wire and/or sensor. - Label the terminals at the sensor end and the controller end. Disconnect the interconnecting wires from the controller and the sensor. With the wires separated at both ends, measure the resistance from wire-to-wire with a multimeter. The meter should read greater than 10 Meg-ohms, open or OL depending on the meter you have. Short the interconnecting wires together at one end. Go to the other end and measure the resistance from wire-to-wire with a multimeter. The meter should read less than 10 ohms (22 gauge or larger, 250 feet or less). If either test fails, replace the wire. - Determine that the temperature sensors wires are connected to the correct controller input terminals and are not loose. - Check the wires at the sensor for proper connections. - Measure the physical temperature at the temperature sensor s location using an accurate temperature standard. Disconnect the temperature sensor wires and measure the temperature sensor s resistance across the sensor output pins with an ohmmeter. Compare the temperature sensor s resistance to the appropriate temperature sensor table on the BAPI web site. If the measured resistance is different from the temperature table by more than 5% call BAPI technical support. Find BAPI s web site at click on the button labeled SENSORS on the left of the screen and then click on the type of sensor you have. Don t forget to reconnect the wires. - Make sure that the test and balance switch is in the correct position. - Make sure that the sensor leads are not touching Setpoint reading is incorrect Override is not working correctly - Make sure that the setpoint output is correct. Remove the setpoint output wire and check the output for the correct resistance or voltage output. See the product label for your specific range. Don t forget to reconnect the wire. - Check that the resistance across the override output is less than 5 ohms when the override switch is pushed. Specifications Power: 5 VDC, 15 to 40 VDC (24 VDC nominal) or 15 to 28 VAC (24 VAC nominal) for Resistive Setpoint Units Only 9 to 40 VDC (24VDC recommended) is required for 0 to 5V setpoint 15 to 40 VDC (24VDC recommended) is required for 0 to 10V setpoint AC power requires a separate pair of shielded wires Power Consumption: 7 ma max DC;.17 VA maximum AC Wiring: 22-14AWG Mounting: Standard 2 x 4 box or drywall direct (Screws provided) Outputs: Passive Sensor Thermistor, ±0.36ºF (±0.2ºC), [XP] ±0.18ºF (±0.1ºC) Platinum RTD, ±0.12%, [A] ±0.06% Nickel RTD, JCI curve External Sensor 10K-2 thermistor (-ES), (Purchased separately) Wired 25 maximum from sensor Setpoint Resistive or Voltage (0 to 10VDC limit) *Isolated Contact resistive Inputs: Dry contact (24V, <1mA) Occupied EXT OVR terminal Grounded Unoccupied EXT OVR terminal Open to Ground Display: LCD, Overall, 2 W x 1.1 H (Temp/Setpoint/Occupied) LCD 3.5 H BAPI-Man Icon Filled is occupied, Hollow is Unoccupied Display limits 0.1º (F/C) temp increments, Setpoints in 0.5º steps Display Setup Temp. & Setpoint, Temp. Only, or Setpoint Only Options: Factory set options Setpoint Slide POT Override Side button Override Operation: Factory Set Momentary shunt across sensor Momentary shunt across setpoint Momentary isolated contact* Latching isolated contact* Setup Options: Offset ±3º Temp Display Display in ºF or ºC Setpoint Resolution Other Options: Comm. jack Disabled or Setpoint display only Display in 0.1º or 0.5º increments 3.5mm phone jack, 3 wires, (-C35) RJ11 jack (-C11) or RJ22 jack (-C22), 4 wires Test & Balance 3 pos. switch (-TB), (Low/Normal/High) Common Gnd. Internal common connection (-CG) Differential Gnd. Each output terminal is isolated (-DF) Colored Plate Warm White (-WMW) or Gray (-GRY) Environmental Ambient: Temperature 32 to 122ºF (0 to 50ºC) Humidity 0 to 95% RH Non-condensing Encl. Material: ABS Plastic, UL94V-0 Agency: RoHS 6 of 6
BAPI-Stat 4MB Modbus Temp or Temp/Humidity Sensor
BAPI-Stat 4MB Modbus Temp or Temp/Humidity Sensor 34350_ins_BS4_modbus Product Identification and Overview The BAPI-Stat 4MB Modbus room temperature or temperature/ humidity sensor is available with optional
More informationPLEASE READ INSTRUCTIONS CAREFULLY BEFORE INSTALLATION!
TUC2 / TUCH2 Model Series Installation Instructions PLEASE READ INSTRUCTIONS CAREFULLY BEFORE INSTALLATION! APPLICATION The TUC2 provides temperature space monitoring with a backlit LCD. The TUCH2 provides
More informationZone Pressure Touch (ZPT) Sensor with Attached Tube (-AT) - Low Pressure Range Unit Installation and Operation Instructions
Product Identification BAPI s Touch Low Range Pressure Sensor with Attached Static Pressure Probe is an accurate, rugged and economical solution for measuring and reporting duct/building static pressure,
More informationZone Pressure Touch (ZPT) Sensor - Standard Range
Product Identification BAPI s Touch Pressure Sensor is an accurate, rugged and economical solution for measuring and reporting duct/ building static pressure, room-to-room differential pressure or air
More informationHT Series Wall Mount with Relay Setpoints, LCD, and Humidistat and Thermostat Control
Wall Mount with Relay Setpoints, LCD, and Humidistat and Thermostat Control NOTICE This product is not intended for life or safety applications. Do not install this product in hazardous or classified locations.
More informationTOXALERT MODEL AIR 2000
TOXALERT MODEL AIR 2000 NOTE: Toxalert s Model GVU-CO 2 Sensor is the same as the Air2000R. Microprocessor-based, Infrared Environmental CO 2 Sensor OPERATOR S MANUAL TOXALERT TM INTERNATIONAL INC. P.O.
More informationHT Series Wall Mount with Analog Setpoints, LCD, and Humidistat and Thermostat Control
Wall Mount with Analog Setpoints, LCD, and Humidistat and Thermostat Control NOTICE This product is not intended for life or safety applications. Do not install this product in hazardous or classified
More informationCTR21, CTR22, CTR23, and CTR24 Wall Modules
CTR21, CTR22, CTR23, and CTR24 Wall Modules FEATURES SPECIFICATION DATA The CTR21, CTR22, CTR23, and CTR24 family of wall modules include: Models with setpoint adjustment. Models with occupied/unoccupied
More informationCDD4 Series Room CO2 Transmitter Installation Instructions
CDD4 Series Room CO2 Transmitter Installation Instructions Introduction The CO2 transmitter uses Infrared Technology to monitor CO2 levels and outputs a linear 4-20 ma or 0-5/0-10 Vdc signal. Options include
More informationC7110C1001A / C7110D1009A WALL MODULES
HONEYWELL EXCEL 5000 OPEN SYSTEM GENERAL The C7110C1001A and C7110D1009A are combined CO2 / temperature wall modules designed for applications in indoor ventilation and air conditioning systems. In conjunction
More informationHardware Installation. Tracer MP581 Programmable Controller CNT-SVN01C-EN
Hardware Installation Tracer MP581 Programmable Controller CNT-SVN01C-EN Hardware Installation Tracer MP581 Programmable Controller CNT-SVN01C-EN November 2005 Tracer MP581 Programmable Controller Hardware
More informationZone Pressure Touch Sensor - Standard Range
Overview The Zone Pressure Touch (ZPT) Sensor is an accurate, rugged and economical solution for measuring and reporting duct/ building static pressure, room-to-room differential pressure or air velocities/volumes.
More informationUNT1100 Series. Binary Output Jumpers AO2 AO1 AO3 AO4 AOCM AOCM AOCM AOCM AO1. AI Switches Job Information N2 Address. Ref N2+ N2- ADDR 0 = ALL OPEN
1 2 8 4 AI6 R R Installation Bulletin UNT1100 Issue Date 0309 UNT1100 Series Introduction The Unitary (UNT) controller (UNT1100 Series) is a digital controller with applications for air handling units,
More informationPrecision humidity/temperature control/sensing
HIGH ACCURACY HUMIDITY/TEMPERATURE TRANSMITTER HAHT Series Precision humidity/temperature control/sensing FEATURES: Highly stable RH sensor element Humidity range: 0-100% Accuracy available 1% & 2% High
More informationInstallation Guide. Room Temperature Sensors. Mounting. Location and Cover Removal (All) STE-6011 Only. STE-6010/6013/6015 Only
Room Temperature Sensors STE-6010/6011/6013/6015 Mounting Location and Cover Removal (All) Install the sensor on an inside wall where it can sense the average room temperature and be away from direct sunlight,
More informationT7560A1036 Digital Wall Module
T7560A1036 Digital Wall Module HONEYWELL EXCEL 5000 OPEN SYSTEM BEFORE INSTALLATION All wiring must comply with local electrical codes and ordinances or as specified on installation wiring diagrams. T7560A1036
More informationCDD Carbon Dioxide Transmitter
Introduction The OSA CO2 transmitter uses Infrared Technology to monitor CO2 levels within a range of 0 2000 ppm and outputs a linear 4-20 ma or 0-5/0-10 Vdc signal. The enclosure is designed to operate
More informationRTT2 ROOM TEMPERATURE SWITCH. Mounting and operating instructions
Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS PRODUCT DESCRIPTION ARTICLE CODES INTENDED AREA OF USE TECHNICAL DATA STANDARDS OPERATIONAL DIAGRAMS WIRING AND CONNECTIONS
More informationCDD4 Duct Carbon Dioxide Transmitter
Drill or punch a 1-1/8 or 1-1/4 hole in the duct at the preferred location and insert the probe into the hole to mark the enclosure mounting holes. Remove the unit and drill the four mounting holes. Clean
More informationLTEC Heat Pump DDC Controller
Document No. 09 Rev., May, 00 LTEC Heat Pump DDC Controller Product Description These instructions explain how to install or replace a LTEC (LonMark Terminal Equipment Controller) HP (Heat Pump) DDC Controller
More informationMeasure & Control Temperature & CO2 levels with analog & digital I/O
MADE IN OZ HTC-DIGITAL-LCD PROGRAMMABLE TEMPERATURE CONTROLLER c/w YEARLY PROGRAMMABLE TIME SWITCH COMPATIBLE WITH A WIDE RANGE OF SENSORS ROOM O/A WALL DUCT PIPE Use Features Measure & Control Temperature
More informationNT10 Series RS485 Modbus RTU Networking LCD Fan Coil Thermostat
Features Modern Appearance Stylish rotary dial and buttons Large LCD with backlight Support Modbus RTU protocol Support standalone operation on RS485 communication failure Retention of temperature set-point
More informationNT50 Series RS485 Modbus RTU Networking LCD Fan Coil Thermostat
NT50 Series RS485 Modbus RTU Networking LCD Fan Coil Thermostat Features Modern Appearance Stylish rotary dial and buttons Large LCD with backlight Support Modbus RTU protocol Support standalone operation
More informationRТTH DUAL ROOM SWITCH
DUAL ROOM SWITCH FOR TEMPERATURE AND RELATIVE HUMIDITY Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS PRODUCT DESCRIPTION ARTICLE CODES INTENDED AREA OF USE TECHNICAL DATA
More informationInstallation and Operation Instructions I/CO 2, I/CO 2 -VDC, I/CO 2 -T
Installation and Operation Instructions I/CO 2, I/CO 2 -VDC, I/CO 2 -T READ THESE INSTRUCTIONS BEFORE YOU BEGIN INSTALLATION LOCATION The I/CO 2 transmitter is designed to mount over a standard single
More informationMODEL: R1M-GH. PC Recorders R1M Series
PC Recorders Series PC RECORDER (thermocouple or DC input, 16 points) Functions & Features Industrial recorder on PC 16-point thermocouple or DC inputs Easy system expansion via Modbus RTU Recorded data
More informationHWS Series Wall Mount with Relay Setpoints, LCD, and Humidistat Control
Wall Mount with Relay Setpoints, LCD, and Humidistat Control NOTICE This product is not intended for life or safety applications. Do not install this product in hazardous or classified locations. Read
More informationInstallation & Operation Guide
Installation & Operation Guide (Shown with optional Override Board Cover) KMD-5831 Programmable Loop Controller PLC-28 Direct Digital Controller 902-019-04B 1 Introduction This section provides a brief
More informationUCU Room Display. Operation Modes. Features. Applications DATASHEET
DATASHEET UCU Room Display The UCU Room Display provides dedicated visually appealing Room Control display for use with UCU10FC/K Unitary Controller. The display allows the user to view and adjust selected
More informationMODEL: R1M-P4. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)
PC Recorders Series PC RECORDER (4 totalized counter inputs, 8 contact inputs and outputs) Functions & Features Industrial recorder on PC Totalized counter inputs Counts stored in E 2 PROM Easy system
More informationProduct Manual SZ2141
Product Manual SZ11 Refrigeration Controller Communicating Controls Description The SZ11 is a microprocessor-based refrigeration controller and alarm interface designed to control three coolers or freezers
More informationTC-9102 Series Surface Mount Temperature Controllers
TC-9102 Series Surface Mount Temperature Controllers General Description & Applications The TC-9102 Series Temperature Controller offers a versatile solution for a wide variety of applications that may
More informationPS-AULDP Series. Overview. Applications. Features & Benefits. Datasheet. Ultra Low Air Differential Pressure Transmitters
PS-AULDP Series Datasheet Ultra Low Air Differential Pressure Transmitters Overview The PS-AULDP Series are ultra-low-pressure transmitters. These devices can be used to measure differential pressure between
More informationSERIES 59. Microprocessor Temperature Controller with Digital Display and RTD, Thermistor or Thermocouple Sensing
SERIES 59 Microprocessor Temperature Controller with Digital Display and RTD, Thermistor or Thermocouple Sensing FEATURES Microprocessor-based no cumbersome menus Large 3-digit LED display permits easy
More informationEP/2 Installation Instructions
1 2 3 4 7 ENTER 0 5 6 8 9 CLEAR + - LOGIC ONE EP/2 EP/2 Installation Instructions DOC. #569011000 A 7/30/04 PRINTED IN U.S.A. Regulatory Compliance Safety This device has been tested and found to be in
More informationDIGITAL PANEL THERMOMETER
Love Controls DIGITAL PANEL THERMOMETER LCI108-2x LCI108J-2x INSTRUCTIONS MANUAL EDITION: February 2001 INTRODUCTION TO THE LOVE CONTROLS LCI108 SERIES This manual does not constitute a formal agreement.
More informationDIGITAL PANEL THERMOMETER
Love Controls DIGITAL PANEL THERMOMETER LCI108-1x LCI108J-1x INSTRUCTION MANUAL EDITION: January 2001 INTRODUCTION TO THE LOVE CONTROLS LCI108 SERIES This manual does not constitute a formal agreement.
More informationMODEL: R1M-A1. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)
PC Recorders R1M Series PC RECORDER (contact input, 32 points) Functions & Features Industrial recorder on PC 32-point dry contact inputs Easy system expansion via Modbus RTU Recorded data exportable to
More informationMiG2 CONTROLLERS. 2 & 4 Stage General Purpose Controllers, with Air-conditioning Facilities
MiG2 CONTROLLERS 2 & 4 Stage General Purpose Controllers, with Air-conditioning Facilities The MiG2 controllers incorporate: 2 Inputs (Configurable as Resistive, 0 10V, 0 20mA or 4 20mA) 2 or 4 Relay Outputs
More informationRS-485 FClink Networking Room Thermostats with LCD for Fan Coil Units
NT10 Series Revision Date April 16, 2014 RS-485 FClink Networking Room Thermostats with LCD for Fan Coil Units Features Ultra slim wall-mount unit to match any decor Supports standalone operation on RS
More informationNEUROLOGIC RESEARCH CORPORATION MODEL 2500
NEUROLOGIC RESEARCH CORPORATION MODEL 2500 NETWORK HUMISTAT Compact, self-contained dehumidifier controller. 0.5 degrees C accuracy typical. RH sensor is digitally calibrated for 2% accuracy. Open communication
More informationLAUREL ELECTRONICS, INC.
LAUREL ELECTRONICS, INC. Laureate RTD Temperature Panel Meter / Controller Features Factory calibrated for 100Ω platinum, 10Ω copper & 120Ω nickel RTDs 2, 3 or 4-wire connection with lead resistance compensation
More informationASI Systems ML5740A Series
ML5740A Series Electric Linear Valve Actuators Non-Spring Return APPLICATION The ML5740A series actuators operate standard ASI Systems valves in heating, ventilating and air conditioning (HVAC) applications.
More informationASI Systems ML5720A Series
ML5720A Series Electric Linear Valve Actuators Non-Spring Return APPLICATION The ML5720A series actuators operate standard ASI Systems valves in heating, ventilating and air conditioning (HVAC) applications.
More information4 10/100/1000T Mini-GBIC with 4 IEEE 802.3at High Power PoE Industrial Wide Temperature Switch. User Manual SISTP LRT
4 10/100/1000T + 2 1000 Mini-GBIC with 4 IEEE 802.3at High Power PoE Industrial Wide Temperature Switch User Manual V1.0 September-2013 FCC Warning This Equipment has been tested and found to comply with
More informationRXTH DUAL ROOM SENSOR / SWITCH
DUAL ROOM SENSOR / SWITCH FOR TEMPERATURE AND RELATIVE HUMIDITY Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE
More informationInstallation, Start-up and Operating Instructions
Installation, Start-up and Operating Instructions EVOLUTION SMART SENSOR FOR ZONING Cancels: NEW II ZONESMS-0-1 7-04 NOTE: Read the entire instruction manual before starting the installation. This symbol
More informationLAUREL. Laureate RTD Temperature Panel Meter / Controller ELECTRONICS, INC. Features. Description. Specifications
LAUREL ELECTRONICS, INC. Laureate RTD Temperature Panel Meter / Controller Features Factory calibrated for 100Ω platinum, 10Ω copper & 120Ω nickel RTDs 2, 3 or 4-wire connection with lead resistance compensation
More informationAnalog Voltage Combination Module
Analog Voltage Combination Module T1F-8AD4DA-2 8-channel analog voltage input 4-channel analog voltage output The combination 8-in and 4-out voltage module uses a T1K-8B or T1K-8B-1 base, which is purchased
More informationMulti-Point Gas Detection and Control System
Multi-Point Gas Detection and Control System DESCRIPTION Wall mounted, microprocessor-based, multi-point, analog electronic control system for various gas, temperature and humidity detection, control and
More informationH7625B; H7635B,C; H7655B Duct-Mount and Outdoor-Mount Humidity/Temperature Sensors
H765B; H7635B,C; H7655B Duct-Mount and Outdoor-Mount Humidity/Temperature Sensors APPLICATION The H765B, H7635B, H7655B Duct-Mount and H7635C Outdoor-Mount Humidity/Temperature Sensors are universal Relative
More informationLOCAL DISPLAY UNIT (LDU)
LOCAL DISPLAY UNIT (LDU) The LDU200 is a LonWorks -based networked user interface panel used to display data and edit setpoint variables for vivariums, bio-containment, laboratory spaces, operating rooms,
More informationSLX Series. Application Specific Controllers (SLX-ASC-FCU-L, SLX-ASC-HPU-L, SLX-ASC-RTU-L, SLX-ASC-UV-L)
SLX Series Document No. 997-1000 Application Specific Controllers (SLX-ASC-FCU-L, SLX-ASC-HPU-L, SLX-ASC-RTU-L, SLX-ASC-UV-L) Free Programmable Controllers (SLX-PC-203, SLX-PC-300, SLX-PC-400, SLX-PC-500
More informationXT-9100 Technical Bulletin
System 9100 Technical Manual 636.4 Technical Bulletins Section Technical Bulletin Issue Date 0896 XT-9100 Technical Bulletin XT-9100 Extension Module/XP-910x Expansion Modules Page 3 Introduction 3 SX
More informationCustom Controller Installation Instructions
MODEL CUSTOM CONTROLLER HARDWARE CODE MAX ALLOWABLE AMBIENT TEMP: 70 C (158 F) THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES. OPERATION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS: 1) THIS DEVICE MAY
More informationModel HU-224/225. Technical Information TI.224/ Humidity Transduce r FOR ADDITIONAL INFORMATION SEE HU-224/225 DATA SHEET
Model /225 FOR ADDITIONAL INFORMATION SEE /225 DATA SHEET SPECIFICATIONS Accuracy*: ± 2% / ± 3% RH Range: 0-100% RH Hysteresis: ± 1% Supply Voltage:12-40 VDC 12-35 VAC (VDC output units only) Supply Current:
More informationMulti-Point Gas Detection and Control System
Multi-Point Gas Detection and Control System Specifications subject to change without notice. USA 40804 Page of 7 DESCRIPTION Wall mounted, microprocessor-based, multi-point, analog electronic control
More informationProduct Manual SZ2144
Product Manual SZ1 Refrigeration Monitor Communicating Controls Description The SZ1 is a microprocessor-based refrigeration monitor and alarm interface designed to monitor up to six coolers or freezers.
More informationWiring Inside the card reader you will see a circuit board. The connections are as follows:
Power Adaptor (12VDC, Max. Current: 1A) If you purchased the Cardlock Series power supply cut the head of the adaptor and strip the insulation. If your locking mechanism, electric strike or magnetic lock
More informationContent. Product Description
EY-modulo 4 EY-RU482F001 Room Operating Unit with Display for Fan Coil applications EY-RU483F001 Room Operating Unit with Display for VAV applications en Guidelines for the electrician Content 1 Product
More information96x48. gal/h. Digital panel meter 4½-digit DV4. Without setpoints. Sensor supply
gal/h Digital panel meter 4½digit DV4 Without setpoints Sensor supply status 22/05/06 panelmeteranalog_gb.doc page 9 Digital panel meter Direct voltage Direct current gal/h Direct voltage, direct current
More informationTECHNICAL PRODUCT DATASHEET
FORM-ENG-0018 REV A 06-02-03 ISO 9001 CERTIFIED Phone: (352) 629-5020 or 800-533-3569 Fax: (352)-629-2902 SUITABLE FOR EXTERNAL DISTRIBUTION TECHNICAL PRODUCT DATASHEET ES-Key Climate Control Module P/N
More informationNetworkable Dual Duct VAV Controller Specification and Installation Instructions
Controller Models EVCBM14NIT2S (Master controller / 2 TRIACs) EVCS14N (Slave controller) TRL Series Thermostat TRL24 (Room Sensor: Temp) TRLH24 (Room Sensor: Temp and %RH) TRLG24 (Room Sensor: Temp and
More informationMulti-Point Gas Detection and Control System
Multi-Point Gas Detection and Control System Specifications subject to change without notice. USA 50729 Page of 9 DESCRIPTION Wall mounted, microprocessor-based, multi-point, analog electronic control
More informationBACnet Flow Controller for Fan Filter Units
MANUAL SERVICE + INSTALLATION BACnet Flow Controller for Fan Filter Units BFC Series v300 Issue Date: 08/23/17 2017 Price Industries Limited. All rights reserved. TABLE OF CONTENTS Product Overview General
More informationStellar Instruments. SC1 Controller & Display System. General User s Manual. Copyright 2013 Stellar Instruments 1
Stellar Instruments SC1 Controller & Display System General User s Manual Copyright 2013 Stellar Instruments 1 Contents Section 1 General... 3 Section 2 Base Unit A (Multi-Event Programmable Timer)...
More informationTM-2100 Series Room Command Module
TM-2100 Series Room Command Module Product Bulletin Code No. 21.144 E Rev. B Issued 02 2007 The TM-2100 series of Room Command Modules are designed for use with the FCC series of DDC terminal unit controllers.
More informationNOTE: Controller must be mounted to minimum of 2 ft2 (0.2m2) 20 gauge metal panel with both sides radiating.
Series 194 7/11/2000 6:31 AM Page 1 CP Scan#1:Desktop Folder:hold:950 Catalog:Series 194.job: Series 194 Thermistor Sensing Temperature Controller With Remote Indicating Meter Option FEATURES Relay or
More informationRS-485 Modbus RTU Networking FCU Thermostats with 0(2)-10 VDC Fan Output
NTAF Series Issue Date March 1, 2018 RS-485 Modbus RTU Networking FCU Thermostats with 0(2)-10 VDC Fan Output Features Ultra slim wall-mount unit to match any décor Supports Modbus RTU protpcol Supports
More informationH7625A, H7635A Humidity/Temperature Sensors
H765A, H7635A Humidity/Temperature Sensors WALL-MOUNT MODELS APPLICATION The H765A, H7635A Wall-Mount Humidity/Temperature Sensors are universal Relative Humidity transmitters that can be powered with
More informationPGR-4700 MANUAL SENSITIVE GROUND-FAULT RELAY
Tel: +1-800-832-3873 E-mail: techline@littelfuse.com www.littelfuse.com/pgr-4700 PGR-4700 MANUAL SENSITIVE GROUND-FAULT RELAY REVISION 2-B-032218 Copyright 2018 by Littelfuse, Inc. All rights reserved.
More informationJunos WebApp Secure 5.0 Hardware Guide
Junos WebApp Secure 5.0 Hardware Guide Junos WebApp Secure 5.0 Hardware Guide This document contains a specification for the MWS1000 hardware appliance, as well as instructions for installation into a
More informationDD1590 Series Proximity Driver. Connection Technology Center, Inc. Vibration Analysis Hardware. DD1590 Series. Proximity Probe Driver.
Connection Technology Center, Inc. Vibration Analysis Hardware DD1590 Series Proximity Probe Driver Product Manual C:\Documents and Settings\mclarneys.ctc\Desktop\MNX10016 DD1590 PROXIMITY PROBE Manual.doc
More informationAllure EC-Smart-Comfort Series
Datasheet Allure EC-Smart-Comfort Series Communicating sensors with Smart-Light and Smart-Blind add-on modules Overview The Allure EC-Smart-Comfort series are versatile communicating sensor which provide
More informationclarity 3 Programmable Controller
clarity 3 Programmable Controller BACnet General Purpose Controllers (B-AAC) DESCRIPTION Taco Clarity 3 FPC series controllers are designed to control building systems and HVAC equipment. The integrated
More informationPROLON INSTALLATION AND START UP GUIDE
PROLON INSTALLATION AND START UP GUIDE Part 1: Project preparation & cabling Figure 1. System disposition and cabling 1- Using a floor plan, determine the system s zone controller locations as well as
More informationRXTP ROOM TEMPERATURE
ROOM TEMPERATURE CONTROLLER WITH PI CONTROL Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE 4 TECHNICAL DATA 4
More informationMODEL: R1M-D1. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)
PC Recorders R1M Series PC RECORDER (contact output, 32 points) Functions & Features Industrial recorder on PC 32-point open collector outputs Easy system expansion via Modbus RTU Recorded data exportable
More informationCDR-RH Room CO 2, Temperature and Humidity Sensors (Controllers)
Product sheet SN1.401 Type CDR-RH CDR-RH Room CO 2, Temperature and Humidity Sensors (Controllers) CDR-RH sensors are designed to detect carbon dioxide concentration, relative humidity and temperature
More informationR1M-GH THERMOCOUPLE & DC INPUT MODULE MODEL. Remote I/O R1M Series. (16 points)
Remote I/O R1M Series THERMOCOUPLE & DC INPUT MODULE (16 points) MODEL MODEL & SUFFIX CODE SELECTION R1MGH2T MODEL Modbus protocol I/O TYPE GH2 : Thermocouple or DC input, 16 points FIELD TERMINAL TYPE
More informationDWYER INSTRUMENTS, INC. Series AVUL Air Velocity Transmitter. Specifications - Installation and Operating Instructions.
Series AVUL Air Velocity Transmitter Specifications - Installation and Operating Instructions Bulletin P-AVUL 3-49/64 [95.71] 2-43/64 [67.92] 1/2 NPS 3-3/16 [80.81] 1-19/32 [40.59] 31/32 24.58 3-33/64
More informationINSTALLATION MANUAL. LC 200 Electronic Overload Guard. Software versione PW0501 R 0.3
INSTALLATION MANUAL LC 200 Electronic Overload Guard Software versione PW0501 R 0.3 CONTENTS MAIN FEATURES LC 200 TECHNICAL FEATURES Page 2 SYMBOLS Page 3 WARNINGS Page 3 IDENTIFICATION DATA PLATE Page
More informationCONTENTS. Chapter 1...Description. Chapter 2...Installation. Chapter 3...Operation. Chapter 4...Calibration. Chapter 5...
CONTENTS Chapter 1...Description Chapter 2...Installation Chapter 3...Operation Chapter 4...Calibration Chapter 5.....Doric Viewer Chapter 6.Specifications Description Chapter 1 The Series 5000 is designed
More informationModel CD-AW. Infrared Environmental CO2 Sensor. Operator's manual
Model CD-AW Infrared Environmental CO2 Sensor Operator's manual Copyright 2011 Date 10/11/11 CD-AW Initial draft 10/20/11 Page: i Table of Contents Preface... 1 Model Identification... 1 Introduction...
More informationTM-2100 Series Room Command Module
TM-2100 Series Room Command Module Product Bulletin Code No. 21.144 E Issued 02 2011 The TM-2100 series of Room Command Modules are designed for use with the FCC series of DDC terminal unit controllers.
More informationInstallation and Operation Guide
Installation and Operation Guide KMD 1162 NetSensor Contents Specifications... 2 Network Cable Preparation... 4 Rough-in preparation... 5 Installing the NetSensor... 5 Operation... 6 Maintenance... 7 Programming
More informationAmplifiers, Counters, Timers & Controls
Amplifiers, Counters, Timers & Controls Panel Meter 814 Counter/Timer/Rate Indicator 815-817 Speed Monitor 818-819 Signal Converter 820-822 Power Supplies/Amplifier 823-824 813 Panel Meter Panel Meter
More informationTX-I/O Product Range. Features. Description. Document No January 24, 2007
Document No. 149-476 January 24, 2007 TX-I/O Product Range Description TX-I/O is a line of I/O modules with associated power and communication modules for use within the APOGEE system. TX-I/O products
More informationComponent identification
IO-ATC8 I/O Expansion Module 8 Analog/Thermocouple Inputs The IO-ATC8 is an I/O Expansion Module that can be used in conjunction with specific Unitronics OPLC controllers. The module offers 8 inputs that
More informationRST ROOM TEMPERATURE TRANSMITTER. Mounting and operating instructions
Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE 4 TECHNICAL DATA 4 STANDARDS 4 OPERATIONAL DIAGRAM 5 WIRING AND
More informationSmartBlock I/O Module HE579MIX102 Isolated 6 Relay, 12 DC Inputs, 4 Analog Inputs
MAN0959-01 PAGE 1 Mix102 module ` SmartBlock I/O Module HE579MIX102 Isolated 6 Relay, 12 DC Inputs, 4 Analog Inputs 1 SPECIFICATIONS Digital DC Inputs Digital Relay Outputs Inputs per Module 12 Outputs
More informationINSTALLATION INSTRUCTIONS
www.altroniccontrols.com INSTALLATION INSTRUCTIONS EXACTA 21 MONITORING AND CONTROL SYSTEM CAUTION: The EXACTA 21 CONTROL SYSTEM is CSA CERTIFIED FOR use in Class I, GROUPS C & D, Division 2 hazardous
More informationGeneral Specifications. P2-08THM Analog Input
General Specifications Operating Temperature Storage Temperature Humidity Environmental Air Vibration Shock Field to Logic Side Isolation Heat Dissipation Enclosure Type Agency Approvals Module Keying
More informationPHS Series. PowerHUBB Node - Satellite
PHS Series PowerHUBB Node - Satellite Project Name NETWORK Catalog No. Date The Hubbell Control Solutions' (HCS) PowerHUBB node provides power distribution architecture and data connectivity to create
More informationMYRIAD QLC 4-CHANNEL MONITOR/CONTROLLER INSTRUCTION MANUAL
MYRIAD QLC 4-CHANNEL MONITOR/CONTROLLER INSTRUCTION MANUAL VISIT OUR WEBSITE SIGMACONTROLS.COM MYR QLC MANUAL 013114 2 TABLE OF CONTENTS INTRODUCTION 3 Ordering Information Specifications Features WIRING
More informationLED55WPG Programmable LED Driver
Dimmable Constant Current Rev 8-9-7 Electrical Specifications Input Voltage Range: Frequency: Power Factor: Inrush Current: Input Current (Max): -77 Vac Nom. (8-35 V Min/Max) 5/6 Hz Nom. (47-63 Hz Min/Max)
More informationField Installation Manual External Bolt-On Economizer for ComPac I Air Conditioners
Field Installation Manual External Bolt-On Economizer for ComPac I Air Conditioners Models: ComPac AVPA 42-48-60 The following instructions describe how to install the Marvair External Bolt-On Field Installed
More informationApplication Engineering
Application Engineering Application Engineering Commercial Comfort Controller (543-0175-00) Installation Guide May 2012 Contents Mounting... 1 Connections and Wiring... 1 Wiring Considerations... 1 Input
More information12-36 VDC/12-24 VAC Power Option 4-Digit Display, 0.56 (14.2 mm) or 1.20 (30.5 mm)
4-20 ma & Relay Output Features 4-20 ma, ± 10 V, TC & RTD Inputs 12-36 VDC/12-24 VAC Power Option 4-Digit Display, 0.56 (14.2 mm) or 1.20 (30.5 mm) 24 VDC @ 200 ma Transmitter Power Supply Options Type
More informationHARDWARE GUIDE. Water Loop Controller C1000 Series. Specifications and Operational Guide
HARDWARE GUIDE Water Loop Controller C1000 Series Specifications and Operational Guide www.proloncontrols.com info@proloncontrols.com 17 510, rue Charles, Suite 100, Mirabel, QC, J7J 1X9 REV. 6.1.6 PL-HRDW-WLC-C1000-C/F-EN
More information