DESIGN GUIDE. Guidance for Designing your InterConnect System

Size: px
Start display at page:

Download "DESIGN GUIDE. Guidance for Designing your InterConnect System"

Transcription

1 DESIGN GUIDE Guidance for Designing your InterConnect System

2 How to Configure a System The following steps help you to determine which VPC products are necessary to complete your system based on your I/O requirements. The steps and using the InterConnect Designer will enable you to properly choose the right equipment to best suit your needs. Step 1. Determine the System s I/O Requirements. A. Number of signal points B. Number of power points C. Number of coaxial points D. Number of other contacts E. Total modules and wired adapters Choosing the signal, power and coaxial points will allow you to determine the modules needed. If you are using cable assemblies, the required modules are already determined. Reference Module Loading Guidance. Step 2. Determine the Receiver. A. Determine the size of the receiver by evaluating the rack height, depth and how many modules you will need plus room for expansion. VPC recommends 20% of the module positions remain open for future growth. B. Determine the mounting style by evaluating accessibility and portability needs. Reference Receiver and Chassis Mounting. Step 3. Determine the Receiver Accessories. A. Receiver Mounting Panel B. Vertical Hinge Mounting Frame (VHMF) C. Plug and Play Mounting Plate D. Receiver Protective Cover E. Slide Kits F. Chassis Mount Kits Reference Receiver and Chassis Mounting and Cable Management.

3 How to Configure a System Step 4. Determine the ITA. A. Determine the Interchangeable Test Adapter (ITA) based on the size of the receiver you have chosen in Step 2. Step 5. Determine the ITA Modules and Contacts. A. The modules for the ITA are the mating modules for the receiver modules you selected in Step 1. B. The ITA contacts mate to the receiver contacts and are dictated by your system s I/O requirements. Step 6. Determine the ITA Accessories. A. ITA Protective Cover B. ITA Patchcords C. ITA Enclosure Reference Wire+ Options.

4 Module Loading Guidance To achieve maximum electrical engagement of the contacts and performance of the VPC interface, it is recommended to load modules with coaxial contacts to the outside of the receiver and ITA frames and modules loaded with signal contacts to the center. VPC also recommends allowing room for expansion, by leaving 20% of the module space in your receiver and ITA open for future growth. When configuring a large-scale system, consult VPC for assistance in determining loading force for maximum performance. COAXIAL POWER SIGNAL BLANK SIGNAL POWER COAXIAL Figure 1. Loading Key.

5 Receiver and Chassis Mounting VPC offers several mounting options for your mass interconnect system. Review the features and benefits below to determine which mounting option will work best for your application. Pull-Thru Visit www. to explore all our mounting options. Slide Mount Pull-Thru Rack/Direct Panel Mount Vertical Hinge Mount Easy access to instrumentation and cables Short wire lengths Chassis and/or instrumentation mounting on different plane than receiver Table Top Must be rack mounted Offer ability to secure cables in place (no movement) Slide Mount Rack Mount Table Top Mount Vertical Hinge Mount

6 Cable Management VPC solutions are designed to accommodate an array of ATE chassis sizes/configurations, including PXI, SCXI, GPIB, LXI, PCI, VXI and AXIe applications. These solutions are available in various wired configurations, including Rack/Direct Panel Mount, Slide Mount, Pull- Thru and Vertical Hinged Mount. Regardless of the type of configuration you choose, cable routing and strain relief are important considerations to make in managing your cabling. For more detailed cable management information, visit /cable or contact VPC to discuss your cable management needs with an application engineer. Strain Relief With any configuration type, strain relief is critical in developing a reliable and consistent tester. VPC offers several strain relief options. Module Strain Relief: The most common method is to attach strain relief plates directly to the modules (Figure 1). Wire or cable bundles are secured to the plate with wire ties, preventing forces exerted on the cables from transferring directly to the contact termination which can cause damage and loss of signal integrity. Cable Tie Down Bar: A second method is to use cable tie-down bars on the receiver side. Figure 1. Module Strain Relief. These bars are included with the G18 Vertical Hinged Mounting Frame and are designed into the instrument bracket or cable tray kits used with slide-mount receivers (Figure 2). When slide mounting your receiver, cables connecting to the receiver should be secured to the strain relief on the instrument bracket. This prevents the cables from being damaged when the slides are extended. Cables routed to instrumentation not placed on the instrument bracket should be secured to the strain relief on the instrument bracket. Figure 2. Cable Tie Down Bar on Instrument Bracket.

7 Cable Management Measuring and Routing Cable Direct Panel Mount Direct Panel Mount systems enable the instrument chassis to be placed directly behind the VPC receiver. When using the direct panel mount method, keep a space of 8-10" from the front of the chassis to prevent tight bends in the cable. To determine the proper cable length required, measure the distance from the front face of the instrument to the module location in the receiver, allowing for bends in the cable for proper cable routing. Cable Tie Down Bar Slide Mount Slide Mount Slide mount configurations, popular for use with PXIbased testers, offer short cable lengths, easy access to instrumentation, and the ability to connect to secondary instrumentation. In addition, the cabling remains static and electrically consistent when accessing instrumentation. When slide-mounting your receiver, consider whether or not the instrument chassis will be placed on an instrument bracket. The recommended cable length is 20" when the instrument bracket is used with a slide-mounted receiver. This length can change if the instrument is being wired to a receiver module on the opposite side of the tester (Figure 3). Figure 3. Slide Mount Configuration Routing. The cables used to connect the instrumentation located somewhere other than the instrument bracket to the receiver must be long enough to allow the slides to extend fully without putting tension on the cables (Figure 3). To determine the appropriate cable length, measure the vertical distance from the receiver to the instrument, then measure the distance from the front of the rack to the receiver with the slides fully extended, taking any bends and special routing into consideration. Vertical Hinged Mount Vertical Hinged Mounting Frames (VHMF) enable the instrument chassis to be placed directly behind the VHMF. When using a VHMF, keep a space of 8-10" from the front of the chassis to prevent tight bends in the cables when the VHMF is closed. To determine the proper cable length required, measure the distance from the front face of the instrument to the module location in the receiver with the VHMF in the open position (Figure 4), allowing for bends in the cable for proper cable routing and allowing extra length in the cable to prevent tight bends when the VHMF is closed. Module Strain Relief Vertical Hinged Mounting Frame /cable Figure 4. Vertical Hinged Mounting Frame Configuration.

8 Wire+ Options When choosing the VPC Wire+ solution to work with your test instrumentation, you may be presented with options for Pull Thru, PCB, and Wire. Read on to learn how to choose: PCB Adapter PCB Adapters offer the convenience of flexibility and the benefit of performance in a lower cost solution. VPC PCB adapters are available in both TriPaddle and QuadraPaddle formats. They allow you to incorporate double ended COTS cables for reduced wiring and ease of integration. VPC offers a wide array of common PXI connectors such as Ribbon Cable Connectors, VHDCI, and SCSI. PCB Adapters are also available in the iseries formats for low I/O applications (i2 Micro icon shown on right). Pull Thru Pull thru solutions should be selected for systems in which a pull thru receiver is being used. Visit our Pull Thru solutions page to see what VPC offers. Haven t picked a receiver yet? Contact your local sales team member to assist in selecting the right system for your application. Wired Wired Solutions provide engineered, finished, and quality tested cable assemblies and patchcords to connect directly into your test instrumentation. Using wire enables system flexibility to access and maintain your setup. Contacts are individually replaceable and your I/O can be modified by adding, removing, or relocating patchcords. Custom cables can also be engineered to combine multiple instruments into one receiver module Contact your local sales team member to find out how. TriPaddle Signal Connection for higher amperage needs. TriPaddle is rated up to 10 Amps. QuadraPaddle Signal Connection for higher density needs. QuadraPaddle is rated up to 5 Amps.

Rapid InterConnect Solutions

Rapid InterConnect Solutions Rapid InterConnect Solutions Rapid InterConnect Solutions The G12 Mass InterConnect from VPC meets the performance demands of today s Electronics Test Industry and offers a low profile solution for rapid

More information

3.3 Integrate Reconfigurable Mass Interconnect Solutions. Evaluating Platforms for Performance and Reusability

3.3 Integrate Reconfigurable Mass Interconnect Solutions. Evaluating Platforms for Performance and Reusability 3.3 Integrate Reconfigurable Mass Interconnect Solutions Evaluating Platforms for Performance and Reusability 157 What is a MASS INTERCONNECT? Creates Order From Chaos 158 Mass Interconnect Standardize

More information

TABLE OF CONTENTS SECTION 1 TABLETOP CONFIGURATION SECTION 2 TABLETOP CONFIGURATION ACCESSORIES SECTION 3 SLIDE CONFIGURATION

TABLE OF CONTENTS SECTION 1 TABLETOP CONFIGURATION SECTION 2 TABLETOP CONFIGURATION ACCESSORIES SECTION 3 SLIDE CONFIGURATION S6 USER S MANUAL TABLE OF CONTENTS SECTION 1 TABLETOP CONFIGURATION SECTION 2 TABLETOP CONFIGURATION ACCESSORIES SECTION 3 SLIDE CONFIGURATION SECTION 4 SLIDE CONFIGURATION ACCESSORIES SECTION 5 RACK MOUNT

More information

G12/G12x USER S MANUAL

G12/G12x USER S MANUAL G12/G12x USER S MANUAL TABLE OF CONTENTS SECTION 1 SLIDE CONFIGURATION SECTION 2 SLIDE CONFIGURATION ACCESSORIES SECTION 3 TABLETOP CONFIGURATION SECTION 4 TABLETOP CONFIGURATION ACCESSORIES SECTION 5

More information

SCXI-1345 Shielded Cable

SCXI-1345 Shielded Cable NATIONAL INSTRUMENTS The Software is the Instrument Installation Guide SCXI-1345 This guide describes how to install the SCXI-1345 shielded cable with an adapter board between an SCXI module and a data

More information

Rack Mount Interconnect Center (RIC3)

Rack Mount Interconnect Center (RIC3) Rack Mount Interconnect Center (RIC) The RIC provides the best overall value for exceptional fiber management. The RIC enclosure offers superior fiber density (up to 88 fibers in just U) without sacrificing

More information

Mass InterConnect Solutions

Mass InterConnect Solutions Test & Measurement Mass InterConnect Solutions...creating order out of wiring chaos. PRODUCT BROCHURE Why VPC? VPC offers over 50 years of unparalleled experience and expertise in the field of Mass InterConnect

More information

Series 3700 Screw Terminal Assemblies Installation Instructions

Series 3700 Screw Terminal Assemblies Installation Instructions Keithley Instruments, Inc. 28775 Aurora Road Cleveland, Ohio 44139 1-888-KEITHLEY www.keithley.com Series 3700 Screw Terminal Assemblies Installation Instructions Introduction This document contains handling

More information

Introducing PXI Instrumentation Into An Existing VXI Based Tester

Introducing PXI Instrumentation Into An Existing VXI Based Tester Introducing PXI Instrumentation Into An Existing VXI Based Tester Kevin Paton Teradyne, Inc. North Reading MA Kevin.Paton@teradyne.com Abstract With the large number of PXI form factor instruments that

More information

Fibre Enlosures and Splicing

Fibre Enlosures and Splicing Fibre Enlosures and Splicing Siemon s fibre enclosures provide feature-rich and easily implemented options for managing critical fibre connectivity. With versions supporting up to 88 fibre ports, Siemon

More information

CW INDUSTRIES IDC SELECTION GUIDE

CW INDUSTRIES IDC SELECTION GUIDE CW INDUSTRIES IDC SELECTION GUIDE An ISO Company that Delivers World Class Quality About CW IDC Connectors CW mass terminated Insulation Displacement Connectors are specifically designed to provide a reliable

More information

FIBRE ENCLOSURES AND SPLICING ACCESSORIES

FIBRE ENCLOSURES AND SPLICING ACCESSORIES F/ F/ Assemblies, 8.0 W W W. S I E M O N. C O M SECTION CONTENTS Rack Mount Interconnect Centre.............. 8. 8. Wall Mount Interconnect Centre...............8. 8.5 F/ Mini Wall Mount Interconnect Centre...............8.5

More information

Section 15 Cable Demarcation Enclosure

Section 15 Cable Demarcation Enclosure Cable Demarcation Enclosure: Section 15 Section 15 Cable Demarcation Enclosure Table of Contents Page Cable Demarcation Enclosure...15-2 Cable Demarcation Enclosure Maximum Protection The enclosure is

More information

BRIC MODULE BRIC ANALOG BACKPLANE BUS MATRIX INPUTS DAUGHTER CARD #3 RESOURCE DISTRIBUTOR DAUGHTER CARD #2

BRIC MODULE BRIC ANALOG BACKPLANE BUS MATRIX INPUTS DAUGHTER CARD #3 RESOURCE DISTRIBUTOR DAUGHTER CARD #2 0-569 Amp BRIC nd Generation PXI Switching Resource Distributor & Bus Matrix Inputs Module Designed to Support the Requirements of the ARINC 608A Specification Integrated PXI A Matrix Module With Built

More information

INSTRUCTION MANUAL RA 55 RACK ADAPTER RACK ADAPTER FOR MST SERIES POWER MODULES

INSTRUCTION MANUAL RA 55 RACK ADAPTER RACK ADAPTER FOR MST SERIES POWER MODULES INSTRUCTION MANUAL RA 55 RACK ADAPTER RACK ADAPTER FOR MST SERIES POWER MODULES KEPCO INC. An ISO 9001 Company. MODEL RA 55 RACK ADAPTER ORDER NO. REV. NO. IMPORTANT NOTES: 1) This manual is valid for

More information

Huntron Access DH. Open Architecture Dual Head Prober for Fixtureless Diagnostic Testing

Huntron Access DH. Open Architecture Dual Head Prober for Fixtureless Diagnostic Testing Huntron Access DH Open Architecture Dual Head Prober for Fixtureless Diagnostic Testing Productivity Challenges of Manually Probing High Density Circuits Vision, Dexterity and Distractions continually

More information

Keysight Technologies TS-8989 System Integration Guide. Application Note

Keysight Technologies TS-8989 System Integration Guide. Application Note Keysight Technologies TS-8989 System Integration Guide Application Note Introduction In today s manufacturing environment, floor space is an increasingly invaluable variable in the cost of test equation.

More information

1. Unpacking the System

1. Unpacking the System 1. Unpacking the System To prevent shipping damage the system is packed in multiple boxes. Chassis The chassis in shipped in one box by itself. The chassis is shipped assembled. Inside the chassis you

More information

This Datasheet for the IC697CHS790. Rack, 9 Slots, Rear Mount.

This Datasheet for the IC697CHS790. Rack, 9 Slots, Rear Mount. This Datasheet for the IC697CHS790 Rack, 9 Slots, Rear Mount. http://www.cimtecautomation.com/parts/p-14771-ic697chs790.aspx Provides the wiring diagrams and installation guidelines for this GE Series

More information

Data Centre Solutions MPO Connectivity with OM3 or OM4 fibre

Data Centre Solutions MPO Connectivity with OM3 or OM4 fibre Data Centre Solutions MPO Connectivity with OM3 or OM4 fibre With this product line 3M offers state of the art connectivity for data centre cabling. The patented modular construction combines highest port

More information

Rack Installation Instructions

Rack Installation Instructions Rack Installation Instructions Review the documentation that comes with your rack cabinet for safety and cabling information. Before installing your server in a rack cabinet, review the following guidelines:

More information

SETTING THE STANDARD FOR HIGH SPEED TESTING

SETTING THE STANDARD FOR HIGH SPEED TESTING SETTING THE STANDARD FOR HIGH SPEED TESTING SETTING A NEW STANDARD Introducing VTAC Right Angle inserts. Following the success of VPC s VTAC High Speed Data (HSD) contact, our engineering team developed

More information

Datasheet. Fiber Optic Modular Patch Panel Features

Datasheet. Fiber Optic Modular Patch Panel Features Features Very high density, supports up to 24 duplex LC adapters (48 fibers), MT-RJ adapters (48 fibers) and simplex SC adapters (24 fibers) in 1U of rack space Pullout drawer enables ease of access to

More information

Installing a Power over Ethernet injector

Installing a Power over Ethernet injector Installing a Power over Ethernet injector AlphaEclipse StreetSmart and RoadStar signs The instructions in this document explain how to install/replace a Power over Ethernet (PoE) injector in a StreetSmart

More information

Product information 19" 3U Global Patch Panel 48xRJ45/u, Cat. 6, partly populated R302361

Product information 19 3U Global Patch Panel 48xRJ45/u, Cat. 6, partly populated R302361 Product information 19" 3U Global Patch Panel 48xRJ45/u, Cat. 6, partly populated R302361 1 Pcs. 19" 3U Global patch panel/u incl. cable tie shelf 12 connection module holders Global/u 3 Global blind covers

More information

ICLS Installation Guidelines

ICLS Installation Guidelines ICLS Installation Guidelines 6 1 1 2 Control Pack / Row Pack 1 2 / Install these components in a easily accessible place near the main input power for the room. The default location is near the main room

More information

16 way 19 1½U enclosure with rear cable management tray NPGZM-16-NJ. ½U high front mounting cable management tray

16 way 19 1½U enclosure with rear cable management tray NPGZM-16-NJ. ½U high front mounting cable management tray Features: Connects 75 ohm coaxial and 120 ohm twisted pair cabling systems Supports all G.703 data rates up to 34 Mbps Snap-in modules are easy to install and maintain Field expandable and upgradable Various

More information

RMG Series Rack Mount Fiber Enclosures

RMG Series Rack Mount Fiber Enclosures The RMG Series rack mount fiber enclosures is as an integral part of the TE Connectivity product portfolio. The RMG Series fiber enclosure provides rugged and durable protection for patching or splicing

More information

V-Built Custom Preconfigured Solutions

V-Built Custom Preconfigured Solutions WWW.SIEMON.COM V-Built Custom Preconfigured Solutions 8 One Part Number, One Price Ready to Roll Available with any Siemon cabinet, rack or enclosure, Siemon s V-Built Custom Preconfigured Solutions are

More information

MPS-Lite. A range of Blank and Connectorized panels in 3 standard widths to fit a 2RU / 3.50 vertical space, plus Adapters to accommodate them.

MPS-Lite. A range of Blank and Connectorized panels in 3 standard widths to fit a 2RU / 3.50 vertical space, plus Adapters to accommodate them. MPS-Lite A range of Blank and Connectorized panels in 3 standard widths to fit a 2RU / 3.50 vertical space, plus Adapters to accommodate them. A size panel (0.90 x 3.50 ) + more B Size panels (1.80 x 3.50

More information

Cable Routing Procedures for Dell PowerEdge R630 Systems

Cable Routing Procedures for Dell PowerEdge R630 Systems Cable Routing Procedures for Dell PowerEdge R630 Systems This Dell Technical White Paper explains the best practices for routing and securing the cables exiting the back of the R630 systems. Rail Solutions

More information

Rack Installation Instructions

Rack Installation Instructions Rack Installation Instructions For System Storage EXP2512 and EXP2524 Express Storage Enclosures Use the instructions in this document to install an IBM System Storage EXP2512 Express Storage Enclosure

More information

Rack Mount Cabinet with Fiber Mgmt System, accepts up to 3 Adapter Plates. Rack Mount Cabinet with Fiber Mgmt System, accepts up to 6 Adapter Plates

Rack Mount Cabinet with Fiber Mgmt System, accepts up to 3 Adapter Plates. Rack Mount Cabinet with Fiber Mgmt System, accepts up to 6 Adapter Plates SEPTEMBER 2009 RACK MOUNT CABINETS Be sure to read and completely understand this procedure before applying product. Be sure to select the proper Optical Cable Corporation product before application. Product

More information

ATM SERIES ATM Series

ATM SERIES ATM Series SERIES Series CONNECTOR SOLUTIONS 21 Series Overview Series connectors are a high-performance, cost-effective solution specifically designed for smaller AWG applications, while still maintaining the strengths

More information

Plug & Play Universal Low-Loss Systems A LANscape Pretium Solutions Product

Plug & Play Universal Low-Loss Systems A LANscape Pretium Solutions Product Applications Data Center LAN/SAN Enterprise Building Backbone -to-the-desk Description Plug & Play Universal Systems are preterminated optical fiber cabling systems designed to dramatically improve performance

More information

Multifunction DAQ Accessory and Cable Selection Guides

Multifunction DAQ Accessory and Cable Selection Guides Multifunction DAQ Accessory and Cable Selection Guides NI Cable Design Advantages The cables designated EP are the most commonly used data acquisition device cables. Each type of cable is designed to work

More information

^2UMAC-CPCIAccessory Cx Family

^2UMAC-CPCIAccessory Cx Family ^1 HARDWARE REFERENCE MANUAL ^2UMAC-CPCIAccessory Cx Family ^3 Compact UBUS Backplane Boards ^4 4Ax-603617-xHxx ^5 January 28, 2003 Single Source Machine Control Power // Flexibility // Ease of Use 21314

More information

The Shop Interface Unit allows MxPro 4 control panels to send and receive alarm signals from other equipment.

The Shop Interface Unit allows MxPro 4 control panels to send and receive alarm signals from other equipment. Shop Interface Unit Features The Shop Interface Unit allows MxPro 4 control panels to send and receive alarm signals from other equipment. Input signals can be received from clean-contact inputs, with

More information

The FTR series interconnection trays are an economical way to manage fiber terminations and

The FTR series interconnection trays are an economical way to manage fiber terminations and Hubbell s FCR series of rack mounted enclosures are the ideal solution for installations requiring fiber patching or fiber slack storage within a 19 or 23 wide rack or cabinet (unit comes with use adjustable

More information

INSTRUCTION MANUAL RA 60 SERIES RACK ADAPTER RA 60, RA 62, AND RA 63. 1) This manual is valid for the following Model and associated serial numbers:

INSTRUCTION MANUAL RA 60 SERIES RACK ADAPTER RA 60, RA 62, AND RA 63. 1) This manual is valid for the following Model and associated serial numbers: INSTRUCTION MANUAL RA 60 SERIES RACK ADAPTER RA 60, RA 62, AND RA 63 KEPCO INC. An ISO 9001 Company. MODEL RA 60 SERIES RACK ADAPTER ORDER NO. REV. NO. IMPORTANT NOTES: 1) This manual is valid for the

More information

2 PIECE BOARD-TO-BOARD

2 PIECE BOARD-TO-BOARD 2 PIECE BOARD-TO-BOARD 201-01-123 1. SPECIFICATION DISTRIBUTION No restrictions for issue 2. SCOPE This specification contains the application notes for the 9159 two part connectors. 3. PRODUCTS 10-9159

More information

LED. Sign Module. Assembly Manual

LED. Sign Module. Assembly Manual LED Sign Module Assembly Manual 6/14/2002 3:10 PM 6 2 3 3 E. S a w g ra s s R d S a ra s o ta, F L. 3 4 2 4 0 (9 4 1 )3 7 7-5 7 7 5 F A X(9 4 1 )3 7 8-4 2 2 6 www.acscontrol.com Table of Contents Table

More information

TrueNet TFP Series Rack Mount Fiber Panels

TrueNet TFP Series Rack Mount Fiber Panels TFP Series Rack Mount Fiber Panels The rack mount TrueNet Fiber Panel (TFP) is an integral part of the TrueNet Fiber product portfolio. The TFP fiber panels can be ordered in one, two and five rack unit

More information

Cable Routing Procedures for Dell PowerEdge T710 Systems

Cable Routing Procedures for Dell PowerEdge T710 Systems Cable Routing Procedures for Dell PowerEdge T710 Systems A Dell Technical White Paper Dell Datacenter Infrastructure Engineering By Chris Kitten and Jose L. Flores March 2011 THIS WHITE PAPER IS FOR INFORMATIONAL

More information

Installation Guide. Retrofit Kit for USB Ready Intraoral Systems

Installation Guide. Retrofit Kit for USB Ready Intraoral Systems Installation Guide Retrofit Kit for USB Ready Intraoral Systems Table of Contents Wall-Mount Retrofit Kit... 2 Introduction... 2 Connecting the Articulating and Horizontal Arm Cables... 2 Installing the

More information

Installing IDS-4235 and IDS-4250

Installing IDS-4235 and IDS-4250 CHAPTER 4 This chapter describes IDS-4235 and IDS-4250 and how to install them. It also describes the accessories and how to install them. IDS-4235 and IDS-4250 are being replaced by IPS-4240 and IPS-4255.

More information

APC by Schneider Electric Solutions for Cisco Unified Computing System (UCS) Blade Applications

APC by Schneider Electric Solutions for Cisco Unified Computing System (UCS) Blade Applications APC by Schneider Electric Solutions for Cisco Unified Computing System (UCS) Blade Applications The Cisco Unified Computing System is a next-generation data center platform that unites compute, network,

More information

Cable Routing Procedures for Dell PowerEdge T320 & T420 Systems

Cable Routing Procedures for Dell PowerEdge T320 & T420 Systems Cable Routing Procedures for Dell PowerEdge T320 & T420 Systems This Dell Technical White Paper explains the best practices for routing and securing the cables exiting the back of the T320 & T420 systems.

More information

DAQ Accessories Selection Guide

DAQ Accessories Selection Guide DAQ Accessories Selection Guide NI Cable Design Advantages National Instruments offers many different high-performance shielded cables that have been specially designed for specific NI multifunction DAQ

More information

PLC Racks IC697CHS782/783

PLC Racks IC697CHS782/783 5 1 PLC Racks IC697CHS782/783 (IC697CHS782/783) datasheet Features Accepts 3rd Party VME modules which require 0.8 spacing. Accepts all IC697 PLC module types. Rear mount rack mounts in a 10 (254 mm) deep

More information

Installing Power Modules

Installing Power Modules This chapter contains the procedures for installing cards and modules into the chassis after the chassis has been installed into a rack. This chapter also describes how to connect cables to RSP, RP, alarm,

More information

SKYLEVEL INSTALLATION Manual

SKYLEVEL INSTALLATION Manual SKLEVEL INSTALLATION Manual Southwest Windpower, Inc. 80 West Route 66 Flagstaff, Arizona 8600 USA Phone: 928-779-9463 Fax: 928-779-485 www.skystreamenergy.com June 2009 Southwest Windpower, Inc. All Rights

More information

E1135C PDU and Pod Upgrade Procedure

E1135C PDU and Pod Upgrade Procedure E4030-90010 Rev. B 12/2003 In this Document... Tools Needed, 2 Contents of the Upgrade Kits, 2 Installation Procedures, 4 Verifying the Power Option of the New PDU, 4 Removing the PDU from the Support

More information

INTERCONNECT SOLUTIONS

INTERCONNECT SOLUTIONS INTERCONNECT SOLUTIONS Products Overview Connect with Us... Experience Makes the Difference Who We Are We have been designing and manufacturing interconnect products for over 40 years. Today we supply

More information

Splice Trays An Evolant Solutions Product

Splice Trays An Evolant Solutions Product Applications For use with indoor or outdoor splice hardware Protects and manages fibers and fiber splices Used at field splice, transition splice and end splice locations Description splice trays use proven

More information

19 Rackmount Cases A3211. Enrich Your Product Line and Build Your Brand Awareness

19 Rackmount Cases A3211. Enrich Your Product Line and Build Your Brand Awareness 19 Rackmount Cases A3211 Enrich Your Product Line and Build Your Brand Awareness 0303-00283 USER S MANUAL Table of Contents 1. Introduction. 1 2. Standard parts. 2 2-1 Disassembly of the Top Cover...2

More information

RACKS AND CABLE MANAGEMENT

RACKS AND CABLE MANAGEMENT F/ F/ Assemblies, 11.0 W W W. S I E M O N. C O M SECTION CONTENTS RS3 Rack System........ 11.2 11.3 RS3 Series Horizontal Managers........... 11.3 F/ RS Rack System............................. 11.4 Extended

More information

INSTRUCTION MANUAL RA 59 RACK ADAPTER. 1) This manual is valid for the following Model and associated serial numbers: MODEL SERIAL NO. REV. NO.

INSTRUCTION MANUAL RA 59 RACK ADAPTER. 1) This manual is valid for the following Model and associated serial numbers: MODEL SERIAL NO. REV. NO. INSTRUCTION MANUAL RA 59 RACK ADAPTER KEPCO INC. An ISO 9001 Company. MODEL RA 59 RACK ADAPTER ORDER NO. REV. NO. IMPORTANT NOTES: 1) This manual is valid for the following Model and associated serial

More information

Cable Dressing and Wiring Workmanship Standard

Cable Dressing and Wiring Workmanship Standard Page 1 of 7 Cable Dressing and Wiring Workmanship Standard Raydon Corporation All rights reserved Page 2 of 7 Revision * A M D Page No. REVISION LOG Paragraph No. Revision Date Affected CRB Control No.

More information

Assembly Instructions

Assembly Instructions Assembly Instructions Flat Screen Garage End User & IT Computer Cable Management May 2013 nylon zip-tie #2 (for computer wires) rear-access beam door (open) Figure 1 nylon zip-tie #1 (for #1 motor control

More information

EMC 10/4 "CE" Mechanical Upgrade Procedure

EMC 10/4 CE Mechanical Upgrade Procedure EMC 10/4 "CE" Mechanical Upgrade Procedure Kit Part Number: 009663-01 This procedure upgrades a non-ce compliant machine to the mechanical requirements of a CE compliant machine. Properly upgraded machines

More information

GX7100 SERIES CHASSIS AND CONTROLLERS 3U / 6U PXI CHASSIS DESCRIPTION CONFIGURATION FEATURES PROGRAMMING AND SOFTWARE APPLICATIONS

GX7100 SERIES CHASSIS AND CONTROLLERS 3U / 6U PXI CHASSIS DESCRIPTION CONFIGURATION FEATURES PROGRAMMING AND SOFTWARE APPLICATIONS 3U / 6U PXI CHASSIS Slots for one 6U (embedded) or 3U (remote) PXI controller, six 6U or 3U instruments, and seven 3U instruments Built-in peripherals (hard disk drive and a DVD-RW drive) for embedded

More information

pickeringtest.com A 2Amp BRIC 2nd Generation PXI Switching 3U PXI Multi Slot Matrix Module

pickeringtest.com A 2Amp BRIC 2nd Generation PXI Switching 3U PXI Multi Slot Matrix Module 40-565A 2Amp BRIC 2nd Generation PXI Switching 3U PXI Multi Slot Matrix Module Integrated PXI 2Amp Matrix Module With Built In High Performance Screened Analog Bus Maximum Current 2A Hot or Cold Switching

More information

Mains termination. (The gland termination plate is mounted immediately behind the mains termination as shown.)

Mains termination. (The gland termination plate is mounted immediately behind the mains termination as shown.) The following kits are available to mount components of the panel in a 19-inch rack. The rack must be purchased separately. daptors are either 3U or 6U heights, as indicated. = earth blade. Mains termination.

More information

LSX Optical Distribution Frame

LSX Optical Distribution Frame LSX Optical Distribution Frame Introduction...79 Things to Consider When Ordering...80 Fiber Distributing Frame...81 Preterminated Fiber Termination Panels with Multifiber Cable-IFC..82 Adapter-Only Fiber

More information

Pretium Rack-mountable 1U Housing Hardware

Pretium Rack-mountable 1U Housing Hardware revision history Issue Date Reason for Change table of contents STANDARD RECOMMENDED PROCEDURE 003-649 ISSUE 5 JANUARY 2009 PAGE 1 OF 10 Pretium Rack-mountable 1U Housing Hardware p/n 003-649, Issue 5

More information

HANDYLINK APPLICATION SPECIFICATION

HANDYLINK APPLICATION SPECIFICATION HANDYLINK I/O CONNECTORS 44828 SMT Receptacle 45560 SMT Cradle Connector Connector 45339 and 45593 Plug Connector Modules A1 HANDYLINK I/O CONNECTOR SYSTEM 2 of 26 Table of Contents Section Page Section

More information

The Series 79 Micro-Crimp Connector

The Series 79 Micro-Crimp Connector The Series 79 Micro-Crimp Connector Covered in This Session 1. The architecture of the MicroCrimp connector, including supported contacts, layouts, and connector styles. 2. The purpose for blind-mate applications.

More information

System Storage EXP3000 Rack Installation Instructions

System Storage EXP3000 Rack Installation Instructions System Storage EXP3000 Rack Installation Instructions Review the documentation that comes with your rack cabinet for safety and cabling information. When you install the IBM System Storage EXP3000 in a

More information

Headline. Improving Development Time of Complex Microwave Test Adapters by Incorporating COTS Components OVERVIEW RELIABLE DATA FIRST TIME EVERY TIME

Headline. Improving Development Time of Complex Microwave Test Adapters by Incorporating COTS Components OVERVIEW RELIABLE DATA FIRST TIME EVERY TIME Improving Development Time of Complex Microwave Test Adapters by Incorporating COTS Components OVERVIEW Creating a unique test system design dedicated to a specific target test article can often be costly,

More information

464K PRELIMINARY 3-STAGE SOLID STATE SWITCH SYSTEMS 464K SALIENT FEATURES SYSTEM OPERATION 464K DESCRIPTION

464K PRELIMINARY 3-STAGE SOLID STATE SWITCH SYSTEMS 464K SALIENT FEATURES SYSTEM OPERATION 464K DESCRIPTION 3-STAGE SOLID STATE SWITCH SYSTEMS PRELIMINARY SALIENT FEATURES SYSTEM OPERATION 3-stage non-blocking solid state switch matrix High density: 65,536 equivalent crosspoints in one mainframe Built-in self

More information

Page. Foreword. We sincerely hope that you enjoy using our product! P2 - INDEX

Page. Foreword. We sincerely hope that you enjoy using our product! P2 - INDEX Page 2... Index, Foreword 3... Product Overview 4... Preparation for Assembly 5-6... Installing the Motherboard 7... PCB Wiring Diagram 8... Fitting the Optical & Hard Drives 9... Installing the PCI Card

More information

Cable Routing Procedures for Dell PowerEdge FX2/FX2s Systems

Cable Routing Procedures for Dell PowerEdge FX2/FX2s Systems Cable Routing Procedures for Dell PowerEdge FX2/FX2s Systems This Dell Technical White Paper explains the best practices for routing and securing the cables exiting the back of the FX2/FX2s systems. Rail

More information

AMP-LATCH RIBBON CABLE INTERCONNECT SOLUTIONS

AMP-LATCH RIBBON CABLE INTERCONNECT SOLUTIONS AMP-LATCH RIBBON CABLE INTERCONNECT SOLUTIONS Quick Reference Guide AMP-LATCH connectors are ribbon cable-to-board devices used to make the transition between ribbon cable and pc board circuitry. They

More information

OMEGA MODULAR PATCH PANEL EMPTY ENCLOSURE

OMEGA MODULAR PATCH PANEL EMPTY ENCLOSURE OMEGA MODULAR PATCH PANEL EMPTY ENCLOSURE The Omega MPP enclosure is based on a 19" frame, with 4 empty module slots for MPP modules. Highly flexible : any mix between twisted pair and optical fiber modules.

More information

7403 K321. Display Wall Mount. Kit Instructions. Issue A

7403 K321. Display Wall Mount. Kit Instructions. Issue A 7403 K321 Display Wall Mount Kit Instructions Issue A ii Revision Record Issue Date Remarks A Nov 2008 First issue 1 Introduction This kit is used in to secure a 7403 Display Head on a vertical surface.

More information

Scope adapters and probes. Surface mount QFP Logic Analyzer adapters

Scope adapters and probes. Surface mount QFP Logic Analyzer adapters Logic Analyzer Adapters Logic Analyzer and scope adapters are designed to give access to each signal pin on a high-density IC. Some variations are specifically adapted to connect to a specific logic analyzer

More information

3M Fiber Distribution Units 8400 Series

3M Fiber Distribution Units 8400 Series Communication Markets Division 3M Fiber Distribution Units 400 Series Flexible options to meet growing needs in limited spaces 3M offers a full line of patch panel designs to simplify your cable management

More information

Flexibility and High Density

Flexibility and High Density Flexibility and High Density High Density High Durability High Diversity DataVoice Modular Patch Panel HD³ Flexibility and high density for optimum results. Space is expensive, especially in data centres

More information

Pandora Assembly Instructions With Diamond Systems PC/104 CPUs (Athena, Elektra and Prometheus) November, 2006

Pandora Assembly Instructions With Diamond Systems PC/104 CPUs (Athena, Elektra and Prometheus) November, 2006 Pandora Assembly Instructions With Diamond Systems PC/104 CPUs (Athena, Elektra and Prometheus) November, 2006 Diamond Systems Corp. (650) 810-2500 www.diamondsystems.com This document describes how to

More information

GX7300 SERIES CHASSIS AND CONTROLLERS 20 SLOT, 3U PXI CHASSIS DESCRIPTION FEATURES CONFIGURATION

GX7300 SERIES CHASSIS AND CONTROLLERS 20 SLOT, 3U PXI CHASSIS DESCRIPTION FEATURES CONFIGURATION 20 SLOT, 3U PXI CHASSIS 20 slots supporting a 3U (embedded or remote) PXI controller and 19 3U PXI or ccpi instruments Built-in peripherals (hard disk drive, and a DVD-RW drive) for embedded controller

More information

Page

Page Page 2... 3... 4... 5-6... 7... 8... 9-11... 12... 13... 14-15... Index, Foreword Product Overview Preparation for Assembly Installing the Motherboard Installing Case Fan & Optional IRRC Wiring Diagram

More information

High Density Switch Mainframe and Cards

High Density Switch Mainframe and Cards Cost-effective, high density switch mainframe and cards High density, half-rack switching mainframe, just 2U (3.5 in) high Differential 6 32 matrix card Differential quad 1 40 multiplexer card Analog backplane

More information

THE SOURCE FOR FIBEROPTIC PRODUCTS

THE SOURCE FOR FIBEROPTIC PRODUCTS PRODUCT CATALOG THE SOURCE FOR FIBEROPTIC PRODUCTS Fiberoptic Interconnect Hardware Century Fiber Optics commitment to service, quality and customer satisfaction is unique in the industry. The knowledgeable

More information

rfi.com.au FIBRE OPTIC ENCLOSURES AND ACCESSORIES

rfi.com.au FIBRE OPTIC ENCLOSURES AND ACCESSORIES rfi.com.au FIBRE OPTIC ENCLOSURES AND ACCESSORIES Product Catalogue Oct 2018 Rack Mount Enclosures Rack Mount Enclosures: SLIDING OCC s rack mountable sliding fibre optic enclosures support the use of

More information

3 Angled Connector Housing (MC) Installation

3 Angled Connector Housing (MC) Installation Angled Connector Housing (MC) Installation Instructions July 1999 4-7047-2554-7 MC Frame Figure 1 Angled Connector Housing (MC) General This document describes the installation of the stubbed MC Angled

More information

LE 2 C CABLE-FREE READ-HEAD LINEAR ENCODER

LE 2 C CABLE-FREE READ-HEAD LINEAR ENCODER LE 2 C CABLE-FREE READ-HEAD LINEAR ENCODER USER GUIDE UG202 COPYRIGHT Copyright 2004 Netzer Precision Motion Sensors Ltd. Changes are periodically made to the information contained in this guide. The changes

More information

INSTALLATION INSTRUCTIONS. ACB-100 Audio Control Board. This document describes the installation procedure for the ACB-100 Audio Control Board.

INSTALLATION INSTRUCTIONS. ACB-100 Audio Control Board. This document describes the installation procedure for the ACB-100 Audio Control Board. INSTALLATION INSTRUCTIONS MicroComm DXI -00 Audio Control Board. Intent & Scope This document describes the installation procedure for the -00 Audio Control Board. 2. Description The -00 Audio Control

More information

FITTING INSTRUCTIONS

FITTING INSTRUCTIONS & This option connects a GL3000 or GL3300 console as a channel expander to a second console with just one or two interconnecting cables. Kit Part No: GL3000-SL1 Single option to install SYS-LINK to one

More information

GX7100 SERIES CHASSIS AND CONTROLLERS 3U / 6U PXI CHASSIS DESCRIPTION CONFIGURATION FEATURES PROGRAMMING AND SOFTWARE APPLICATIONS

GX7100 SERIES CHASSIS AND CONTROLLERS 3U / 6U PXI CHASSIS DESCRIPTION CONFIGURATION FEATURES PROGRAMMING AND SOFTWARE APPLICATIONS 3U / 6U PXI CHASSIS Slots for one 6U (embedded) or 3U (remote) PXI controller, six 6U or 3U instruments, and seven 3U instruments Built-in peripherals (hard disk drive and a DVD-RW drive) for embedded

More information

Spec Sheet. TrueNet TFP Series Rack Mount Fiber Panels. Features: Applications and Benefits:

Spec Sheet. TrueNet TFP Series Rack Mount Fiber Panels. Features: Applications and Benefits: ADC introduces the TFP Series rack mount fiber panels as an integral part of the TrueNet Fiber product portfolio. The TFP Series fiber panels can be ordered in one, two and five rack unit sizes and are

More information

HC900 Controller. Controller CPU and Scanner Module Installation and Replacement

HC900 Controller. Controller CPU and Scanner Module Installation and Replacement HC900 Controller and Scanner Module Installation and Replacement Scanner 1 Scanner 2 (for redundant controller) 900C51 - (current revision number) 900C52 - (current revision number) 900C31 - (current revision

More information

RittalXpress TS IT Enclosure Assemble-to-Order Program

RittalXpress TS IT Enclosure Assemble-to-Order Program RittalXpress TS IT Enclosure Assemble-to-Order Program DESIGN YOUR DATA CENTER BY THE NUMBERS. Count down to success: 4, 3, 2, 1... Complete four easy steps, your order can be shipped in three days and

More information

Installation Guide for Mazak Mazatrol M - Plus, M-2, M32, T-Plus, T2

Installation Guide for Mazak Mazatrol M - Plus, M-2, M32, T-Plus, T2 1 Installation Guide for Mazak Mazatrol M - Plus, M-2, M32, T-Plus, T2 Tsubis Part Number: LCD12-0046 Power Down 1. Power down the controller. 2. Power down the complete machine by turning off the rear

More information

Technical Note. Configuring Functional ATE Systems. Developing Your ATE System. Online at

Technical Note. Configuring Functional ATE Systems. Developing Your ATE System. Online at Many years ago, when a company's product was in the manufacturing cycle and needed to be tested, it was common for product verification to be performed manually by test technicians or operators. Test procedures

More information

3M I/O Connector Mounting Options and Hardware

3M I/O Connector Mounting Options and Hardware M I/O Connector Mounting Options and Hardware Hardware Guide Date Modified: July 20, 2009 Part Number Type Mounting Hardware Applications - Table 1 Mini D Ribbon (MDR) Conn. s D Sub Conn. s D Ribbon Conn.

More information

FCI-TTI Fine Pitch Mezzanine Presentation. Conan 1.0mm BergStak 0.8mm MezzoStak 0.5mm

FCI-TTI Fine Pitch Mezzanine Presentation. Conan 1.0mm BergStak 0.8mm MezzoStak 0.5mm FCI-TTI Fine Pitch Mezzanine Presentation Conan 1.0mm BergStak 0.8mm MezzoStak 0.5mm 1 FCI-TTI Fine Pitch Mezzanine Conan 1.0mm 2 Contents Fine Pitch Mezzanine Presentation Conan 1.0mm Pages 2-15 BergStak

More information

PRELIMINARY APPLICATION SPECIFICATION

PRELIMINARY APPLICATION SPECIFICATION SEARAY BOARD TO BOARD INTERCONNECT SYSTEM 4970 / 466 SMT Plug Connector (shown with kapton pad for pick and place) 4971 / 467 SMT Receptacle Connector (shown with kapton pad for pick and place) SEARAY

More information

Racal Instruments 1257A. Scalable RF Interface Unit. Product Information. The Racal Instruments 1257A is a Commercial-Off-The

Racal Instruments 1257A. Scalable RF Interface Unit. Product Information. The Racal Instruments 1257A is a Commercial-Off-The Racal Instruments 1257A Scalable RF Interface Unit The is a sixth-generation RFIU design with four Commercial Off-The-Shelf (COTS) options from 1U to 4U. It comes with a new easy-to-use LXI Core 2011-compliant

More information

EASTERN LABS. Instructions Model RM /25/2007. Operation. Junction Box Assembly. Different Types of Switch Installations

EASTERN LABS. Instructions Model RM /25/2007. Operation. Junction Box Assembly. Different Types of Switch Installations EASTERN LABS Instructions Model RM-1205 04/25/2007 Operation Junction Box Assembly Different Types of Switch Installations Counter Mounting Suggestions Operation Total Counter Mix Counter Thru counter

More information