Product Design Assessment (PDA) Certificate for Component Details

Size: px
Start display at page:

Download "Product Design Assessment (PDA) Certificate for Component Details"

Transcription

1 Product Design Assessment (PDA) Certificate for Component Details HIMax X-CPU01 Processor X-SB01 System Bus X-COM01 PS1000 X-DI X-DI 3201 X-DI 3202 X-DI 3203 X-DI 3204 X-DI 3205 X-DI 1601 X-AI 3201 X-AI 3202 X-CI X-AO 1601 X-DO 3201 X-DO X-DO X-DO 1201 X-DO 1202 X-DI X-DI 3251 X-DI 3252 X-DO 3251 X-DO 1251 X-AI 1651 X-AI 3251 X-CI A-AO 1651 X-Base-Plate X-Fan 10/15/18 X-HART 3201 X-MIO 7/601 Communication Power Supply Unit Digital Input, 8.2 V DC Digital Input, 48 V DC, SOE (sequence of event) Digital Input, 8.2 V DC, proximity switches, SOE Digital Input, 120 V AC Analog Input, 4 20 ma Analog Input, 4 20 ma, SOE Counter, 0 20 khz Analog Output, 4 20 ma, pairwise galvanically isolated Digital Output, 24 V DC, 0.5A, line monitoring SC Digital Output, 24 V DC, 0.5A, line monitoring OC/SC Digital Output, 48 V DC, 0.5A, line monitoring OC/SC Relay Output, 230 V AC/DC, current measurement Digital Output, 24 V DC, 2 A, line monitoring SC Digital Input, 8.2 V DC, proximity switch, line monitoring OC/SC Digital Output, 24 V DC, 0.5A, protected outputs Digital Output, 230 V AC/DC Analog Input, 0/4 20 ma, ± 280 mv, galvanically isolated Analog Input, 0/4 20 ma, line monitoring OC/SC Counter, 0 20 khz Analog Output, 0/4 20 ma Base Plate, 10/15/18 Slots, redundant supply 2/3/4 fans, for X-Base-Plate HART Module, 24 V DC Over speed Trip Module Page 1 of 5

2 PDA Certificate No: Product/Equipment: 14-HG PDA Programmable Logic Controller HIMax H7014 Feed Line and Distribution, Fuse Board H7201 Feed Line and Distribution, Fuse Board H7202 H4135A H4011 H4012 H4116 H4007 H6210 H6200A H7505 Feed Line and Distribution, Fuse Board H devise, Relay with electronic housing H device, Switching Amplifier (Ex)i, SIL 3 H device, Switching Amplifier (Ex)i, SIL 3 H device, Relay with electronic housing, SIL 2 H device, Switching Amplifier (Ex)i, SIL 1 to SIL 4 HART multiplexer 8-fold HART, Analog repeater power supply H device, Interface converter H7506 H device, Bus terminal K7214 Distribution, 120A with 18 circuit breaker slots for 24 V DC H41q, H51q B Redundant Central Unit + 1 channel bus B Redundant Central Unit + redundant bus B9302 1/2 input-output busses F3221 F3222 F3224A F3236 F3237 Input, 16 channel binary, with safety isolation Input, 8 channel, with safety isolation Input, 4 channel Ex(i), with safety isolation Input, 16 channel binary, safety related Input, 8 channel, safety related F3238 Input, 8 channel Ex(i), safety related, SIL 3 F3240, F3248 Input, 16 channel, safety related, SIL 3 F3320 F3325 Output, 16 channel, with safety isolation Output, 6 channel supply unit Ex(i) for transmitter Page 2 of 5

3 H41q, H51q F3330, F3331 Output, 8 channel, safety related F3333, F3334 Output, 4 channel, safety related, SIL 3 F3335 F3348 F3349 F3422 F3430 F3322 F5220 F6215 F6217 F6220 F6221 F6705 F6706 F7126/30A Output, 4 channel Ex(i), safety related, SIL 3 Output, 8 channel, safety related, SIL 3 Output, 8 channel, with safety isolation Output, 8 channel relay module Output, 4 channel relay module, SIL 3 Supply Unit, 6 channel Ex(i) Counter, 2 channel, SIL 3 Analogue Input, 8 channel, with safety isolation Analogue Input, 8 channel, safety related, SIL 3 Analogue Input, 8 channel, thermocouple Ex(i), SIL 3 Analogue Input, 8 channel Ex(I), SIL 3 D/A Converter, 2 channel, SIL 3 D/A Converter, with safety isolation Power Supply, 24 V DC, out 5V DC F7131 Power Supply with back-up batteries F7132/33 Power Distribution, 4 channel F7 53 Coupling, with switch-off of watchdog signal F8621, -A Communication F8627/X Communication, Ethernet F8628/X F8650/52/A/E,X Communication, Profibus Central-Processor B9361 Power Supply, 5V DC Planar fold Input, SIL 4/ Cat fold Input, Ex(i), SIL4/ Cat fold Output, 25V DC, SIL 4/ Cat Output, 25V DC, SIL 4/ Cat Output, 60 V DC, SIL 4/ Cat fold relay amplifier, 24 V AC/DC fold relay amplifier, 48/60 V DC, 60 V AC fold relay amplifier, 110 V DC, 127 V AC fold relay amplifier, 220 V DC, 230 V AC fold relay amplifier, 220 V DC, 230 V AC Page 3 of 5

4 Planar fold AND element fold OR element /2-fold, AND/ OR element fold OR element fold Invert element fold selection element Time delay element fold time delay element Analogue limit monitor, 0/4 20 ma, 0/1 5V Communication, Modbus Communication, Profibus Communication, Ethernet, OPC Communication, Modbus Communication, Profibus Communication, Ethernet, OPC Reset module fold Fuse module fold Bypass module Sub-rack with bus, connection: pins for soldering Sub-rack with bus, connection: pins for soldering Sub-rack with bus, connection: pins for termi-point/ wire-wrap Sub-rack with bus, connection: pins for termi-point/ wire-wrap Sub-rack with bus, connection: pins for soldering Sub-rack with bus, connection: pins for soldering Sub-rack with bus, connection: pins for termi-point/ wire wrap Page 4 of 5

5 HIMatrix F30 Compact System, Digital Input, Digital Output F31 01 Compact System, Digital Input, Digital Output, Ethernet F31 02 F35 F60 F20 Compact System, Digital Input, Digital Output, Ethernet Compact System, Digital Input, Digital Output, Analogue Input CPU, Counter, Digital In-/Output, Analogue In-/Output Compact System Digital Input, Digital Output, Ethernet Page 5 of 5

TYPE APPROVAL CERTIFICATE

TYPE APPROVAL CERTIFICATE TYPE APPROVAL CERTIFICATE Certificate No: TAA000011N This is to certify: That the Programmable Electronic System with type designation(s) HIMA HIMAX and Planar4 System Issued to HIMA Paul Hildebrandt GmbH

More information

INTRINSICALLY SAFE INSTRUMENTATION FOR HAZARDOUS AREAS

INTRINSICALLY SAFE INSTRUMENTATION FOR HAZARDOUS AREAS INTRINSICALLY SAFE INSTRUMENTATION FOR HAZARDOUS AREAS SHORT FORM 2002 SERIES D1000 Intrinsically Safe Galvanic Isolators SERIES D1000, for DIN Rail Mounting, provide the most simple and cost effective

More information

List of Components Versions for Safetec SFT-9000 systems

List of Components Versions for Safetec SFT-9000 systems SAFETEC srl Certificate No.: 01/205/5591.00/17 Table 1a: SIL3-Certified HW Components Report-Number ST DIN-10 DIN-1007.00-XXXX ST DIN-11 DIN-1107.00-XXXX safety digital input card, 2x12 NAMUR inputs safety

More information

MTL8000-2/x Series Modular I/O

MTL8000-2/x Series Modular I/O -2/x Series Modular Overview Modules Modules - Overview - 2/2 components Use this option for general purpose or nonhazardous applications, or where the equipment and/or field wiring has to be mounted in

More information

MIC-2 MKII, Multi-instrument DATA SHEET

MIC-2 MKII, Multi-instrument DATA SHEET MIC-2 MKII, Multi-instrument DATA SHEET Measurements All 3-phase AC measurements True RMS 4-Quadrant energy Power Quality Analysis Replaces analogue meters RS-485 Modbus RTU protocol TCP/IP Modbus (optional)

More information

S800 I/O ABB Automation

S800 I/O ABB Automation S800 I/O 3BCNIIT F HW02-S800-V0102 Rev. 02/01 Page 1 S800 I/O S800 I/O 3 : Fieldbus Communication Interface (FCI) I/O Module Module Termination Unit (MTU), Compact or Extended version 3BCNIIT F HW02-S800-V0102

More information

Bedrock OSA Features and Benefits

Bedrock OSA Features and Benefits Bedrock OSA Features and Benefits Bedrock OSA Features and Benefits - 0217 Page 1 of 9 1. Backplane Module Interconnect, (BMI) Bedrock OSA BMI Features Sealed all-metal construction. Electronically passive,

More information

MIC-2 Multi-instrument DATA SHEET

MIC-2 Multi-instrument DATA SHEET Measurements All 3-phase AC measurements True RMS 4-Quadrant energy Power Quality Analysis Replaces analogue meters RS-485 Modbus RTU protocol TCP/IP Modbus (optional) Profibus DP (optional) I/O modules

More information

MXIO. Compact I/O module. Summary. Application Compact I/O module for data acquisition and HVAC control systems. Function

MXIO. Compact I/O module. Summary. Application Compact I/O module for data acquisition and HVAC control systems. Function MXIO Compact I/O module Summary The MXIO multiple I/O compact module is a microprocessor-controlled, communicative module with the I/O mix optimized for larger HVAC control applications. The module uses

More information

MIC-2 MKII & MIC-2 MKII DIN, Multi-instrument DATA SHEET

MIC-2 MKII & MIC-2 MKII DIN, Multi-instrument DATA SHEET & DIN, Multi-instrument DATA SHEET Measurements All 3-phase AC measurements True RMS 4-Quadrant energy Power Quality Analysis Replaces analogue meters RS-485 Modbus RTU protocol TCP/IP Modbus (optional)

More information

Redundant System Redundant System P9-1-1

Redundant System Redundant System P9-1-1 .. P-- Overview - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - P-- idcs-8830/idcs-8830r - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

More information

AIAS. Technical description

AIAS. Technical description Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains AIAS - and Efficient Heating Demand Products Controlled Tunnel Ventilation Fans 1 / 4 AIAS Technical description 2 / 9 AIAS -

More information

LB Remote I/O. CEAG Sicherheitstechnik GmbH 256

LB Remote I/O. CEAG Sicherheitstechnik GmbH 256 LB Remote I/O Description LB Remote I/O modules are used as signal conditioning units between field devices and control systems. They plug into a backplane system which is mounted on a standard DIN rail.

More information

Intrinsic Safety Control Drawing

Intrinsic Safety Control Drawing s Intrinsic Safety Control Drawing system in total PLC PC Not hazardous area PROFIBUS DP Associated Apparatus Class I, DIV 2, GP A...D Class I, ZN 1, IIC T4 PROFIBUS-DP Ex i Terminating resistor Class

More information

xlogic SuperRelay is a compact and expandable CPU replacing mini PLCs, multiple timers, relays and counters.

xlogic SuperRelay is a compact and expandable CPU replacing mini PLCs, multiple timers, relays and counters. SuperRelay S UPERR ELAY, THE PERFECT ALTERNATIVE TO LOW COST PLCs AND BASIC RELAYS IN THIS BROCHURE: ELC 18 Standard Models ELC 18 Economy Models ELC 12 Standard Models ELC 16 Expansion Modules ELC SMS

More information

DATA ACQUISITION PRODUCT-ETHERNET

DATA ACQUISITION PRODUCT-ETHERNET 2-channel Analog Output Module, with DO Number of Output Channel: 2 Resolution: 12-bit Input type: 0~5V/10V, 0~20mA, 4~ ~20mA (tripartite isolation) DAM-E3062 1-channel Analog Output Module, with DO Number

More information

DATA SHEET Applicable for offshore or nearshore

DATA SHEET Applicable for offshore or nearshore AWC 400 Advanced Wind Turbine Controller DATA SHEET Applicable for offshore or nearshore environments Unrivalled robustness 5-year warranty Open programming in ANSI C/C and IEC63-3 DEIF A/S Frisenborgvej

More information

SAFETY. HIMax Safety Manual

SAFETY. HIMax Safety Manual SAFETY HIMax Safety Manual All HIMA products mentioned in this manual are protected by the HIMA trademark. Unless otherwise noted, this also applies to other manufacturers and their respective products

More information

Features and Benefits. Certifications

Features and Benefits. Certifications iopac 8600 Series Rugged modular programmable controllers Features and Benefits Modular CPU/power/backplane design that supports 85M/86M modules Tag-centric design with ready-to-run services Supports C/C++

More information

MXPLC. Compact PLC process station. Summary. Application HVAC control systems, data acquisition, interfacing 3 rd party systems.

MXPLC. Compact PLC process station. Summary. Application HVAC control systems, data acquisition, interfacing 3 rd party systems. MXPLC Compact PLC process station Summary The MXPLC is a programmable process station with integrated I/O module with the I/O mix optimized for larger HVAC control applications. The multi-interface process

More information

Table of Contents. Chapter 1: Getting Started. Chapter 2: Specifications

Table of Contents. Chapter 1: Getting Started. Chapter 2: Specifications Chapter 1: Getting Started Introduction...1 2 The Purpose of this Manual...1 2 About Getting Started...1 2 Supplemental Manuals and Other Help...1 2 Technical Support...1 2 Conventions Used...1 3 Key Topics

More information

Accessories. Embedded Control. Order number: Flash-RAM memory module, 128 K x 16 (for 680I) Accessories

Accessories. Embedded Control. Order number: Flash-RAM memory module, 128 K x 16 (for 680I) Accessories Order number: 680.428.03 Flash-RAM memory module, 128 K x 16 (for 680I) This module combines the benefits of both modules. Save your data in the permanently built-in RAM. The flash-eproms are programmed

More information

8600 RTU Serial Port Status Cable Assembly for PCM v1.8 25x86 LP Drawings

8600 RTU Serial Port Status Cable Assembly for PCM v1.8 25x86 LP Drawings 8600 RTU Serial Port Status Cable Assembly for PCM-4862 1 v1.8 25x86 LP Drawings 8600 RTU Serial Port Status Cable Assembly for PCA-6135L 2 v1.8 25x86 LP Drawings 2572 RS-232 Status Board Connection 3

More information

Data sheet VIPA CPU 115DP (115-6BL22)

Data sheet VIPA CPU 115DP (115-6BL22) Data sheet VIPA CPU 115DP (115-6BL22) Technical data Order no. Type 115-6BL22 VIPA CPU 115DP General information Note - Features Work memory [KB]: 16 Load memory [KB]: 24 Onboard 16x DI / 12x DO / 4x DIO

More information

MARINE CERTIFIED PRODUCTS BY PEPPERL+FUCHS

MARINE CERTIFIED PRODUCTS BY PEPPERL+FUCHS FIELDBUS Power Hub with Power Supply Modules KLD2-FBPS-1.25.360 HD2-FBPS-1.25.360 HD2-FBPS-1.500 HD2-FBPS-1.23.500 HD2-FBPS-1.17.500 Fieldbus Power Supply, 25 V/360 ma, stand-alone, DIN-rail mountable

More information

Data sheet CC 03, Commander Compact (603-1CC21)

Data sheet CC 03, Commander Compact (603-1CC21) Data sheet CC 03, Commander Compact (603-1CC21) Technical data Order. Type 603-1CC21 CC 03, Commander Compact General information Note - Features Display: 2 x 20 characters Interface: MP²I User memory:

More information

Multi-instrument Communication, MIC-2 MKII DIN Quick Start Guide

Multi-instrument Communication, MIC-2 MKII DIN Quick Start Guide Multi-instrument Communication, MIC-2 MKII DIN Quick Start Guide Warnings and legal information Installation and terminals Communication I/O options Alarming Utility software More information Specifications

More information

WAGO-I/O-SYSTEM. Fieldbus Technology. for Use in Hazardous Areas

WAGO-I/O-SYSTEM. Fieldbus Technology. for Use in Hazardous Areas WAGO-I/O-SYSTEM Fieldbus Technology for Use in Hazardous Areas For Use in Hazardous Areas The WAGO-I/O-SYSTEM 0 is a modular, fi eldbus-independent I/O system for decentralized automation. This system,

More information

xlogic! CPU Built-in Ethernet

xlogic! CPU Built-in Ethernet xlogic! CPU Built-in Ethernet Reduce cost for you: the well-proven logic module now also with Micro Automation Version:V 1.0 Easy Electronic Co., Ltd Standard for communication with further xlogic/x-messenger

More information

Intrinsically Safe Barriers

Intrinsically Safe Barriers Intrinsically Safe Barriers Description Page No. Safety Barriers 464-472 Din Rail Isolated Barriers 473-488 477 Intrinsically Safe Barriers Product Overview We have simplified intrinsic safety! Cooper

More information

7415 x. Made in Germany. fluid sensors and diagnostic systems. position sensors and object recognition bus, identification and control systems

7415 x. Made in Germany. fluid sensors and diagnostic systems. position sensors and object recognition bus, identification and control systems 7 x Made in Germany 00 fluid sensors and diagnostic systems position sensors and object recognition bus, identification and control systems Easy adjustment and parameter setting. Clear CD display with

More information

Product and Applications Description. Note. Example of Operation. Installation Instructions. Application Programs WARNING

Product and Applications Description. Note. Example of Operation. Installation Instructions. Application Programs WARNING Product and Applications Description Note If the application program is not loaded completely by the ETS, you had better interrupt the 24 V voltage supply of the I/O-module during the loading interval.

More information

restart: hima/factory_automation/presses HIMA The development of press automation is complete.

restart: hima/factory_automation/presses HIMA The development of press automation is complete. The development of press automation is complete. Paul Hildebrandt GmbH + Co KG P.O. Box 1261 68777 Brühl Germany Telephone: (+49 62 02) 7 09-0 Telefax: (+49 62 02) 7 09-1 07 E-mail: info@hima.com Internet:

More information

Controller Modules Main Feature Part Number MOXoc Dynamic CPU 1x Ethernet MX

Controller Modules Main Feature Part Number MOXoc Dynamic CPU 1x Ethernet MX MOX Open Controller MOX Open Controller Controller Modules Main Feature Part Number MOXoc Dynamic CPU 1x Ethernet MX601-5004 MOXoc Dynamic CPU +RDN 1x Ethernet, Optical RDN Link, SOE Sync Port MX601-5002

More information

Engineering Guideline. pac-carriers Type for Honeywell system Experion Series C I/O

Engineering Guideline. pac-carriers Type for Honeywell system Experion Series C I/O Engineering Guideline pac-carriers Type 995 for Honeywell system Experion Series C I/O pac-carrier Type 995 Engineering Guideline/Honeywell 04..009 pac-carrier Type 995 Integration of conventional process

More information

HIMax Safety Manual SAFETY

HIMax Safety Manual SAFETY HIMax Safety Manual SAFETY All HIMA products mentioned in this manual are protected by the HIMA trade-mark. Unless noted otherwise, this also applies to other manufacturers and their respective products

More information

BẢNG GIÁ PLC SIEMENS S7-300 Áp dụng từ 01/01/ Giá chưa bao gồm thuế VAT

BẢNG GIÁ PLC SIEMENS S7-300 Áp dụng từ 01/01/ Giá chưa bao gồm thuế VAT BẢNG GIÁ PLC SIEMENS S7-300 Áp dụng từ 01/01/2011 - Giá chưa bao gồm thuế VAT NO I SIMATIC S7-300 Central Processing Unit 1 6ES7312-1AE13-0AB0 SIMATIC S7-300, CPU 312 CPU WITH MPI INTERFACE, INTEGRATED

More information

Wago Ethernet Driver Help Kepware Technologies

Wago Ethernet Driver Help Kepware Technologies 1 Kepware Technologies Table of Contents Table of Contents 4 Overview 4 Device Setup 5 P/IP 5 Block Sizes 5 Slot Configuration 7 Digital Input Modules 7 Digital Output Modules 8 Analog Input Modules 9

More information

Programmable Systems The H41q and H51q System Families

Programmable Systems The H41q and H51q System Families Programmable Systems The H41q and H51q System Families Catalog HIMA Paul Hildebrandt GmbH + Co KG Industrial Automation HI 800 263 DEA Caution The safety-related H41q/H51q systems as described in this

More information

CONTROL TECHNOLOGY INC Middlebrook Pike, Knoxville, TN Phone FAX

CONTROL TECHNOLOGY INC Middlebrook Pike, Knoxville, TN Phone FAX , Phone 865.584.0440 Product Family: 2500 Series Programmable Controller System 2500-40F Face 40 Terminal Block 2500P-ACP1 Application Coprocessor 2500-ADP1 Analog Wiring Adapter 2500-ADP2-DISC Discrete

More information

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs E031026 000823 Process modules Digital input PMI for inputs for 120 V AC inputs PMI Input E4, E5, GND L- PMI 120 V AC Input E4, E5, Common C E6, E7, GND L- E6, E7, Common C LEDs for the inputs operation

More information

TSXPAY262 Preventa safety module - 24 V DC - standard format - < 5 W

TSXPAY262 Preventa safety module - 24 V DC - standard format - < 5 W Characteristics Preventa safety module - 24 V DC - standard format - < 5 W Main Range of product Product or component type Complementary [Us] rated supply voltage Supply voltage limits Activation threshold

More information

EXOcompact Third Generation Manual

EXOcompact Third Generation Manual EXOcompact Third Generation Manual DISCLAIMER The information in this manual has been carefully checked and is believed to be correct. AB Regin however, makes no warranties as regards the contents of this

More information

Safety Barriers. CEAG safety barriers can be used for all kinds of instrumentation applications.

Safety Barriers. CEAG safety barriers can be used for all kinds of instrumentation applications. Safety Barriers Description Safety barriers limit the energy fed to an intrinsically safe circuit so that neither sparks nor thermal effects (hot surfaces) can cause an explosion. CEAG safety barriers

More information

HC900 Process Controller Modules Specifications

HC900 Process Controller Modules Specifications HC900 Process Controller Modules Specifications 51-52-03-41, June 15 Overview The Honeywell HC900 Process Controller is an advanced loop and logic controller offering a modular design sized to satisfy

More information

Module 4. Programmable Logic Control Systems. Version 2 EE IIT, Kharagpur 1

Module 4. Programmable Logic Control Systems. Version 2 EE IIT, Kharagpur 1 Module 4 Programmable Logic Control Systems Version 2 EE IIT, Kharagpur 1 Lesson 22 The PLC Hardware Environment Version 2 EE IIT, Kharagpur 2 Instructional Objectives After learning the lesson students

More information

Data sheet CPU 315SB/DPM (315-2AG12)

Data sheet CPU 315SB/DPM (315-2AG12) Data sheet CPU 315SB/DPM (315-2AG12) Technical data Order no. 315-2AG12 CPU 315SB/DPM General information Note - Features SPEED-Bus - SPEED7 technology 1 MB work memory Memory extension (max. 2 MB) PROFIBUS-DP

More information

SPX 1hr product overview Eaton Corporation. All rights reserved.

SPX 1hr product overview Eaton Corporation. All rights reserved. SPX 1hr product overview 2012 Eaton Corporation. All rights reserved. Eaton Product Offering Machinery OEM Drives DE1, DC1, DE1, DA1, M-Max HVAC Drives H-Max 0.25HP 25HP 1HP 250HP General Purpose Industrial

More information

Programmable Logic Controllers. and Components for Industrial Automation. altus. evolution in automation.

Programmable Logic Controllers. and Components for Industrial Automation. altus. evolution in automation. Programmable Logic Controllers and Components for Industrial Automation altus www.altus.com.br evolution in automation Segmentation Every automation system features unique characteristics that require

More information

Product Brochure PMA KS Multi-function Controller.

Product Brochure PMA KS Multi-function Controller. Product Brochure PMA KS 98-2 Multi-function Controller Overview Automation made easy PMA s multi-function instrument KS 98-2 combines PID control, process monitoring, sequence control, data logging and

More information

SICAM RTUs Ready for the Future

SICAM RTUs Ready for the Future SICAM RTUs Ready for the Future, RC-AT EM DG PRO LM siemens.com SICAM RTUs News Overview SICAM A8000 Series SICAM Engineering SICAM AK3 Page 2 SICAM RTUs News Overview SICAM A8000 Series SICAM Engineering

More information

AUDIO MANAGEMENT SYSTEM

AUDIO MANAGEMENT SYSTEM AUDIO MANAGEMENT SYSTEM Network-enabled for extended system installations in various locations and for efficient centralized control, the SX-2000 Series sets a new standard for high-performance, no-compromise

More information

HIMax Nonstop safety for everyone who thinks ahead

HIMax Nonstop safety for everyone who thinks ahead HIMax Nonstop safety for everyone who thinks ahead HIMax Safety is a must. Productivity as well High plant productivity thanks to intelligent safety solutions Do you wish safety solutions that neither

More information

CO General Specifications GS48D62Z00-00E-N GENERAL. ProSafe-COM extended communication system

CO General Specifications GS48D62Z00-00E-N GENERAL. ProSafe-COM extended communication system General Specifications GS48D62Z00-00E-N CO-962-00 ProSafe-COM extended communication system GENERAL Figure 1 ProSafe-COM extended communication system is a multiple protocol communication interface connecting

More information

Terminal Block Catalog Numbers 1719-TB6, 1719-TB6S, 1719-TB8, 1719-TB8S, 1719-TB8Sx2, 1719-TB8x2

Terminal Block Catalog Numbers 1719-TB6, 1719-TB6S, 1719-TB8, 1719-TB8S, 1719-TB8Sx2, 1719-TB8x2 Technical Data Communication Adapter Catalog Number 1719-AENTR I/O Module Catalog Numbers 1719-IJ, 1719-IBN8B, 1719-IF4HB, 1719-IR4B, 1719-IT4B, 1719-OB2, 1719-OB2L, 1719-CF4H Power Supply Catalog Number

More information

DTMF Device/ Relay Remote Controller

DTMF Device/ Relay Remote Controller DTMF Device/ Relay Remote Controller This high quality board is designed to get DTMF input from Internet / Mobile / Wireless receivers/ Computer for operation of 4 relays. AC 250 V AC rated Relays can

More information

SCADAPack. I/O Expansion & Communication Modules

SCADAPack. I/O Expansion & Communication Modules SCADAPack I/O Expansion & Communication Modules 1 Welcome to the SCADAPack family of I/O Expansion and Communication modules, providing flexible I/O and telemetry options. With the addition of I/O Expansion

More information

S900 Remote I/O System Intrinsic safety in the field ABB

S900 Remote I/O System Intrinsic safety in the field ABB S900 Remote I/O System Intrinsic safety in the field ABB 2 S900 REMOTE I/O SYSTEM INTRINSIC SAFETY IN THE FIELD The S900 Remote I/O System 01 Example of Field housing FH660S in stainless steel with complete

More information

IO-DI8-TO8 I/O Expansion Module 8 Inputs, 8 Outputs

IO-DI8-TO8 I/O Expansion Module 8 Inputs, 8 Outputs IO-DI8-TO8 I/O Expansion Module 8 Inputs, 8 Outputs The IO-DI8-TO8 is an I/O expansion module that can be used in conjunction with specific Unitronics OPLC controllers. The module offers 8 digital inputs,

More information

General information. Supply voltage

General information. Supply voltage Data sheet SIMATIC S7-300, CPU 313C-2DP COMPACT CPU WITH MPI, 16 DI/16 DO, 3 FAST COUNTERS (30 KHZ), INTEGRATED DP INTERFACE, INTEGRATED 24V DC POWER SUPPLY, 128 KBYTE WORKING MEMORY, FRONT CONNECTOR (1

More information

2014 Drives Pricelist

2014 Drives Pricelist 0.37 to 560 kw, ACS850 Supply voltage 380-500 V Motor control method - Direct torque control (DTC) or scalar control What is an ABB machinery drive? ABB machinery drives are designed to meet the production

More information

PAC BI-DP BIM and 8701-CA-BI Carrier

PAC BI-DP BIM and 8701-CA-BI Carrier June 2013 PAC8000 8507-BI-DP BIM and 8701-CA-BI Carrier PROFIBUS DP Bus Interface Module and Carrier The 8507-BI-DP Bus Interface Module (BIM) provides the communications link between the PAC8000 series

More information

SR Mini HG SYSTEM. FAREX SR Mini HG SYSTEM. General Description. Features. Up to 320 control loops* 2 in one system. Flexible installation

SR Mini HG SYSTEM. FAREX SR Mini HG SYSTEM. General Description. Features. Up to 320 control loops* 2 in one system. Flexible installation FAEX S Mini HG SYSTEM S Mini HG SYSTEM General Description The S Mini HG SYSTEM is a DIN-ail mounted multi-loop control system. This product consists of block-type compact modules so that the configuration

More information

XPSMF35. Product data sheet Characteristics. Preventa safety PLC compact - Profibus DP protocol. Main. Complementary. Safety module name

XPSMF35. Product data sheet Characteristics. Preventa safety PLC compact - Profibus DP protocol. Main. Complementary. Safety module name Product data sheet Characteristics XPSMF3542 Preventa safety PLC compact - Profibus DP protocol Main Range of product Product or component type Safety module name Safety module application Nov 13, 2018

More information

iopac 8500 Series Rugged modular RTU controllers Overview Programmable Controllers High Sampling Rate Analog Input Prerecord Feature

iopac 8500 Series Rugged modular RTU controllers Overview Programmable Controllers High Sampling Rate Analog Input Prerecord Feature Programmable Controllers iopac 8500 Series Award-winning Product Rugged modular RTU controllers Dedicated ARM (RISC) CPUs for the main system and each I/O module Millisecond timestamp granularity for digital

More information

VersaPoint I/O. Proficy Machine Edition. Publication Reference Chart

VersaPoint I/O. Proficy Machine Edition. Publication Reference Chart Distributed I/O The VersaPoint Distributed I/O system provides compact flexibility and allows users to install just the right amount of I/O needed for each application. Adhering to open communications

More information

Data sheet CPU 115 (115-6BL02)

Data sheet CPU 115 (115-6BL02) Data sheet CPU 115 (115-6BL02) Technical data Order no. 115-6BL02 Type CPU 115 General information Note - Features 16 (20) inputs 16 (12) outputs from which are 2 PWM 50 khz outputs 16 kb work memory,

More information

ICP DAS. ICP DAS 2015 M2M WLAN Wireless Solutions

ICP DAS. ICP DAS 2015 M2M WLAN Wireless Solutions ICP DAS 2015 M2M WLAN Wireless Solutions Industrial Computer Industrial Product Data Computer Acquisition Product System Data Acquisition System PAC WLAN Wireless Solutions Wi-Fi Products WLAN Converter

More information

SCADAPack ES. Smart RTU

SCADAPack ES. Smart RTU Smart RTU 1 Meeting the demands for high-speed distributed control and automation systems, Schneider Electric offers the SCADAPack ES as an advanced Smart RTU. Our highest performance Smart RTU built on

More information

NTX Series Product Comparison

NTX Series Product Comparison NTX Function Primary design application Pole-top/pad-mount switch automation; small substation installations Small substation installations with medium serial and Ethernet port requirements Some legacy

More information

HIMax. Maintenance Manual MAINTENANCE

HIMax. Maintenance Manual MAINTENANCE d HIMax Maintenance Manual MAINTENANCE All HIMA products mentioned in this manual are protected by the HIMA trade-mark. Unless noted otherwise, this also applies to other manufacturers and their respective

More information

Intech Micro 2300-A8VI analogue input station MODBUS RTU slave application supplementary manual.

Intech Micro 2300-A8VI analogue input station MODBUS RTU slave application supplementary manual. Intech Micro 2300-A8VI analogue input station MODBUS RTU slave application supplementary manual. MODBUS supplementary manual to the 2300-A8VI Installation Guide. The 2300 series stations are designed to

More information

KeControl C5 and KeConnect C5. The flexible control generation

KeControl C5 and KeConnect C5. The flexible control generation KeControl C5 and KeConnect C5 The flexible control generation KEBA C5 Control Generation For all those who expect more from an automation system With the ultramodern C5 control generation KEBA sets new

More information

Multi-instrument Communication, MIC-2 MKII DIN Quick Start Guide

Multi-instrument Communication, MIC-2 MKII DIN Quick Start Guide Multi-instrument Communication, MIC-2 MKII DIN Quick Start Guide Warnings and legal information Installation and terminals Communication I/O options Alarming Utility software More information Specifications

More information

SCADAPack ES. Smart RTU

SCADAPack ES. Smart RTU Smart RTU 1 Meeting the demands for high-speed distributed control and automation systems, Schneider Electric offers the as an advanced Smart RTU. Our highest performance Smart RTU built on a native DNP3

More information

TURCK Process Automation IS Interface Technology. Interface Modules. IM Series Cabinet

TURCK Process Automation IS Interface Technology. Interface Modules. IM Series Cabinet Process Automation IS Interface Technology Interface Modules TURCK's IM series of Isolating Intrinsically Safe Barriers is designed to be a simple and safe way to solve the problems associated with the

More information

FEATURES DESCRIPTION FEATURES

FEATURES DESCRIPTION FEATURES FEATURES Two High Speed Counters Two Pulse Train Outputs Two Pulse Width Modulation Outputs 24 Sinking or Sourcing Inputs 16 Outputs 1 RS232 Port 2 RS485 Ports Supports Modbus RTU Protocol Communicate

More information

Innovation for system integration

Innovation for system integration Innovation for system integration PERFORMANCE MADE SMARTER PR backplane A user-friendly and reliable mounting solution between the DCS/PLC/SIS system and isolators/i.s. interfaces TEMPERATURE I.S. INTERFACES

More information

Compact 800 Our control applications are simple and effective

Compact 800 Our control applications are simple and effective Compact 800 Our control applications are simple and effective The only control products you need for your automation applications Compact 800 is a range of products that can be used individually or combined

More information

RS 485 Mini Modbus 1AO

RS 485 Mini Modbus 1AO RS 485 Mini Modbus 1AO Version 1.0 14/08/2014 Manufactured for Thank you for choosing our product. This manual will help you with proper support and proper operation of the device. The information contained

More information

Ver. 01. FnIO S-Series. Integrated Systems for the Speed and Quality

Ver. 01. FnIO S-Series. Integrated Systems for the Speed and Quality Ver. 01 FnIO S-Series Integrated Systems for the Speed and Quality Convenience Economics Stability Considered Design for User. Compact Size : We applied Ultra-small size RTB(Removable Terminal Block) and

More information

vacon nx user manual basic i/o boards expander i/o boards adapter i/o boards ac drives

vacon nx user manual basic i/o boards expander i/o boards adapter i/o boards ac drives vacon nx ac drives basic i/o boards expander i/o boards adapter i/o boards user manual vacon 2 General information. GENERAL INFORMATION VACON NX range embodies a wide selection of expander and adapter

More information

Drawn by Matthew Fox & Peter Vieira. Revised by Andrew Geck. Drawing List LEGEND. DC Power. AC Power. Control/DAQ. Current Transformer

Drawn by Matthew Fox & Peter Vieira. Revised by Andrew Geck. Drawing List LEGEND. DC Power. AC Power. Control/DAQ. Current Transformer LEGED DC Power AC Power Control/DAQ Current Transformer DC Circuit Breaker Circuit Breaker w/ Shunt Trip and AUX Feedback Disconnect / Switch Fan (Axial) Drawn by Matthew Fox & Peter Vieira Fuse ormally

More information

Intech Micro 2300-RO4 analogue input station MODBUS RTU slave application supplementary manual.

Intech Micro 2300-RO4 analogue input station MODBUS RTU slave application supplementary manual. Intech Micro 2300-RO4 analogue input station MODBUS RTU slave application supplementary manual. MODBUS supplementary manual to the 2300-RO4 Installation Guide. The 2300 series stations are designed to

More information

Multifunction controller GHM-ONE MSR9696H. Multifunction controller. Features. ... professional Instruments M ADE IN GERMANY

Multifunction controller GHM-ONE MSR9696H. Multifunction controller. Features. ... professional Instruments M ADE IN GERMANY GHM-ONE MSR9696H Quick and easy to put ideas into practice The creation of applications is child s play with the MSR 9696H. Based on the concept of connecting of existing function blocks, the user creates

More information

Backplane. Allen-Bradley. System integration. Backplane

Backplane. Allen-Bradley. System integration. Backplane Backplane System integration Allen-Bradley Backplane Backplanes designed for minimum overall life cycle costs Simple, reliable and professional design Using standard cost-optimised DIN-rail devices Flexible

More information

MOTION COORDINATOR MC403 / MC403-Z Quick Connection Guide

MOTION COORDINATOR MC403 / MC403-Z Quick Connection Guide 8 DIGITAL INPUTS INCLUDING 6 X REGISTRATION INPUTS AND 4 BI-DIRECTIONAL I/O 2 ANALOGUE INPUTS AND 2 VOLTAGE OUTPUT AND WDOG RELAY CAN PORT FOR TRIO CAN I/O, DEVICENET SLAVE, CANOPEN OR USER PROGRAMMABLE

More information

Data sheet CPU 315SB/DPM (315-2AG12)

Data sheet CPU 315SB/DPM (315-2AG12) Data sheet CPU 315SB/DPM (315-2AG12) Technical data Order no. 315-2AG12 CPU 315SB/DPM General information Note - Features SPEED-Bus - SPEED7 technology 1 MB work memory Memory extension (max. ) PROFIBUS-DP

More information

Termination Board FC-GPCS-RIO16-PF. Features. Assembly. Function. Connection USIO/UPIO 24 V DC (I), 24 V DC (II) Fault. Zone 0, 1, 2 Div.

Termination Board FC-GPCS-RIO16-PF. Features. Assembly. Function. Connection USIO/UPIO 24 V DC (I), 24 V DC (II) Fault. Zone 0, 1, 2 Div. Features Assembly System board for Honeywell Universal Safety IO System board for Honeywell Universal Process IO For 6-channel cards USIO and UPIO For 6 modules Recommended modules: HiC8R (DI), HiC85R

More information

Backplane. System integration. Backplane

Backplane. System integration. Backplane Backplane System integration Backplane Backplanes designed for minimum overall life cycle costs Simple, reliable and professional design Using standard cost-optimised DIN-rail devices Flexible connection

More information

3 CU240E-2 6SL3244-0BB12-1BA1 3 CU240E-2 DP 6SL3244-0BB12-1PA1. RS485/USS 6 3 (opt. per 2 DI) 3 CU240E-2 F 6SL3244-0BB13-1BA1

3 CU240E-2 6SL3244-0BB12-1BA1 3 CU240E-2 DP 6SL3244-0BB12-1PA1. RS485/USS 6 3 (opt. per 2 DI) 3 CU240E-2 F 6SL3244-0BB13-1BA1 Control Units CU240B-2, CU240E-2 Overview Safety Integrated functions The basic version of the CU240E-2 series (CU240E-2 and CU240E-2 DP) includes the safety function Safe Torque Off (STO) (certified according

More information

Sturdy and Powerful ACOS 750

Sturdy and Powerful ACOS 750 Sturdy and Powerful ACOS 750 The Scalable Automation and Telecontrol Device for Every Challenge ACOS 750 A Powerful Allrounder in the ACOS 7 Series IDS automation and telecontrol technology of the ACOS

More information

S-series Electronic Marshalling

S-series Electronic Marshalling DeltaV Distributed Control System Product Data Sheet July 2017 S-series Electronic Marshalling I/O anywhere you need it Single channel granularity Reduces installed cost of system Fully redundant architecture

More information

SIMATIC S7-200 PRICE LIST

SIMATIC S7-200 PRICE LIST BẢNG GIÁ PLC SIEMENS S7-200 SIMATIC S7-200 PRICE LIST Part number SIMATIC S7-200 CLASSIC (GERMANY ORIGIN) SIMATIC S7-200 Central Processing Unit 6ES7211-0AA23-0XB0 6ES7211-0BA23-0XB0 6ES7212-1AB23-0XB0

More information

ABB Product Group PLC ABB Programmable Logic Control AC500 Presentation

ABB Product Group PLC ABB Programmable Logic Control AC500 Presentation 3ADR025066N020 ABB Product Group PLC ABB Programmable Logic Control AC500 Presentation 13 May 2013 Slide 1 Compatible platform interchangeable modules Single programming software World-class operations

More information

6ES7212-1BD30-0XB0. permissible range, lower limit (DC) permissible range, upper limit (DC)

6ES7212-1BD30-0XB0. permissible range, lower limit (DC) permissible range, upper limit (DC) 6ES7212-1BD30-0XB0 Page 1 Product data sheet 6ES7212-1BD30-0XB0 SIMATIC S7-1200, CPU 1212C, COMPACT CPU, AC/DC/RLY, ONBOARD I/O: 8 DI 24V DC; 6 DO RELAY 0,5A; 2 AI 0-10V DC, POWER SUPPLY: AC 85-264 V AC

More information

CLIMATIX STEQ, STCM DATASHEET FOR CONTROLLING, SWITCHING AND MONITORING FUNCTIONS. POWER SUPPLY RELAY OUTPUTS. Power supply. 4.

CLIMATIX STEQ, STCM DATASHEET FOR CONTROLLING, SWITCHING AND MONITORING FUNCTIONS. POWER SUPPLY RELAY OUTPUTS. Power supply. 4. CLIMATIX STEQ, STCM DATASHEET FOR CONTROLLING, SWITCHING AND MONITORING FUNCTIONS. 4. Relays Power supply 2. Relays 8. Universal Inputs/ Process Bus (KNX) RS485 (Modbus) Tool (USB) Ethernet Tool (USB)/

More information

Integrated Control Panels Utnytt dine digitale muligheter Basic Automation TIA Portal. Siemens AG 2017

Integrated Control Panels Utnytt dine digitale muligheter Basic Automation TIA Portal. Siemens AG 2017 Integrated Control Panels Utnytt dine digitale muligheter Basic Automation TIA Portal Siemens AG 2017 www.siemens.com/panelbuilding Example of a network topology Actuators & Sensors in TIA Portal S7 1500

More information

Data sheet CPU 315SN/NET (315-4NE12)

Data sheet CPU 315SN/NET (315-4NE12) Data sheet CPU 315SN/NET (315-4NE12) Technical data Order no. 315-4NE12 CPU 315SN/NET General information Note - Features SPEED-Bus - SPEED7 technology 1 MB work memory Memory extension (max. 2 MB) PROFIBUS-DP

More information

Termination Board FC-GPCS-SAI16-PF. Features. Assembly. Function. Connection. SAI-1620m HART 24 V DC (I), 24 V DC (II) Fault. Zone 0, 1, 2 Div.

Termination Board FC-GPCS-SAI16-PF. Features. Assembly. Function. Connection. SAI-1620m HART 24 V DC (I), 24 V DC (II) Fault. Zone 0, 1, 2 Div. Features Assembly System board for Honeywell Safety Manager For 6-channel AI card SAI-60m For 6 modules Recommended module: HiC05 (AI) 4 V DC supply Hazardous area: pluggable screw terminals, blue Non-hazardous

More information