This network (Figure 5) has a Panel-Version Facilitator, Operator Terminal, five controllers, and a repeater.

Size: px
Start display at page:

Download "This network (Figure 5) has a Panel-Version Facilitator, Operator Terminal, five controllers, and a repeater."

Transcription

1 This network (Figure 5) has a Panel-Version Facilitator, Operator Terminal, five controllers, and a repeater. Facilitator Panel Operator Terminal RS- Panel = EOL In W = across and W = across and DX900 AHU Side A: EOL Jumpers = In LAYOUT Figure 5: Facilitator Network With Panel, Five controllers, and Network Communications N Communications Bus

2 This network (Figure 6) has a PC-Version Facilitator in the middle of the and a branched repeater. DX900 Facilitator PC Converter = EOL In (W = across and W = across and ) AHU Side A: EOL Jumpers=In Side B: EOL Jumpers=In AHU LAYOUT Figure 6: Facilitator Network With PC in Middle of N and Branched 4 Network Communications N Communications Bus

3 Facilitator Panel Operator Terminal RS- Panel = EOL In W = across and W = across and Note: Since the repeater delays the signal between Sides A and B, a maximum of two repeaters can be cascaded (connected in series). A B Side A=N EOL Out Side B=N EOL In AHU A B Side A=N EOL In Side B=N EOL In A B Side A=N EOL Out Side B=N EOL In AHU Side A=N EOL In Side B=N EOL In B A LAYOUT4 This network (Figure 7) has the branching from multiple repeaters. The branch can be at either Side A or B. Multiple branches off one side are also allowed, as long as the device and distance limitations are followed. This network shows three segments. Figure 7: Facilitator Network with Several Branched s Wiring Guidelines The is wired to the N terminals on the converter (PC-Version only), Facilitator Panel, or controller. Be sure to follow these rules: Network Communications N Communications Bus 5

4 Enclosure MM-CVT0-x or Panel Companion Enclosure ASC Enclosure ASC REF Cable Housing REF Cable Housing REF Notes: Hard Ground Ground within " of enclosure's EXIT 560 pf Soft Ground Ground within " of enclosure's ENTRY Hard Ground Ground within " of enclosure's EXIT 560 pf Soft Ground Ground within " of enclosure's ENTRY Hard ground within " of each enclosure.. Soft ground outside the enclosure within " of each ASC with a 560 pf capacitor. SHIELD Always make sure the input wires you connect to the N terminals are twisted together and the output wires from the N terminals are twisted together. This is shown in Figures 8 and 9. Also, keep these wires twisted up to within an inch or two of the actual screw terminals. To maintain consistency throughout the, use the same color wires for the inputs and outputs (e.g., always use the orange wire for the input and the white wire for input). This helps to ensure a working the first time and makes troubleshooting easier should a problem occur. Always wire the input, and REF (reference) lines, regardless of the type of wire used. If the wire has three conductors, terminate the third wire (and any spare conductors) to REF. Shielded cable is generally not required, except in very high noise environments, such as near gas ignition systems and radar or magnetic resonance imaging equipment. If you must use shielded wire, wire the bus as shown in the following example (Figure 8). Figure 8: Using Shielded Wire on Wiring the PC Wire the to the converter of the PC. The converter has three wire terminals labeled,, and REF. Connect the converter to the COM (serial) port in back of the computer as shown in Figure 9. If this serial port has 9 pins instead of 5, use a 9-to-5-pin interface cable (DB9F-DB5M). Install the interface cable between the PC and the converter. Plug in the converter s transformer. 6 Network Communications N Communications Bus

5 Facilitator PC (backside) Parallel Port Serial Port Serial Port Video Port Note: If Serial Port requires a 9-pin connector, an interface cable from 9-pin to 5-pin is required. RS-to-N Converter Twisted Pair Telephone Cable Notes: We recommend stranded AWG or heavier wire. Experience has shown that solid 4/6 AWG wire is prone to breakage during installation. REF REF-IN REF-IN REF-OUT REF-OUT IN (-) OUT (-) IN (+) OUT (+) Twisted Twisted Wires that are labeled "OUT" and "REF-OUT" are only used if the must continue to another device. For two twisted pair cable, terminate one pair to (+) and (-), and terminate one or both wires of the other pair to REF. REF REF-IN REF-OUT IN (-) OUT (-) IN (+) OUT (+) Wire Twisted Cable NPCWIRE Figure 9: Wiring PC-Version Facilitator to Network Communications N Communications Bus 7

6 Wiring the Panel Circuit Board in Panel Power LED Twisted Pair Telephone Cable GRD REF REF-IN REF-IN REF-OUT REF-OUT IN (-) OUT (-) IN (+) OUT (+) Wire Twisted Cable Twisted Twisted W W4 P RS- Terminal Connector W J J4 Microprocessor W GRD REF REF-IN REF-OUT IN (-) OUT (-) IN (+) OUT (+) Notes: We recommend stranded AWG or heavier wire. Experience has shown that solid 4/6 AWG wire is prone to breakage during installation. P RS- Modem Connector P RS- Printer Connector N LED Diagnostics LED Wires that are labeled "OUT" and "REF-OUT" are only used if the must continue to another device. For two twisted pair cable, terminate one pair to (+) and (-), and terminate one or both wires of the other pair to REF. NPNWIRE Wire the to the terminal block on the Panel-Version Facilitator as shown in Figure 0. Be sure to maintain proper polarity. Figure 0: Wiring Panel-Version Facilitator to Wiring s Installing the The is wired to the dedicated N terminals on each controller. For details, refer to the appropriate controller technical bulletin under the s section. You can use the repeater in three different configurations: station, branch, or star. As these configurations show in Figures, and, the maximum length from the PC/Panel Facilitator to the farthest controller can be 5,000 feet. This is the farthest distance the signal can travel. Note, however, that the grand total of all segments can be much longer than 5,000 feet. For example, in Figure, the grand total is 4,000 feet. 8 Network Communications N Communications Bus

7 Panel Version PC Version OR 5,000' 5000' OR 50 Devices* A B A B s AHU * Includes both repeaters. REPEATCN The station configuration, shown in Figure, has repeaters wired in between the controllers. Figure : Station Configuration Network Communications N Communications Bus 9

8 The branch configuration, shown in Figure, has multiple repeaters wired together, and a separate branch of controllers off each repeater. Panel Version PC Version OR 000' 000' 500' 500' 000' 5000' 5000' 000' 4000' 000' Note: Branches can be at Side A or B. REPEATC AHU Figure : Network Branch Configuration 0 Network Communications N Communications Bus

9 Central Location Panel Version PC Version OR EOL In Note: Maximum cable distance between two repeaters is 5000 feet. ' 5000' A: EOL Out A: EOL Out A: EOL Out 4997' A: EOL In B: EOL In B: EOL In B: EO L In B: EOL In 5000' 5000' 5000' 5000' Self Terminated 5000' A: EOL In B: EOL In DX900 Self Terminated Self Terminated AHU Self Terminated REPEATST Self Terminated Figure shows the star configuration, in which the first three repeaters are installed in a central location and a controller is wired from each repeater. Figure : Star Configuration Network Communications N Communications Bus

10 The instructions for installing the repeater include setting the baud rate, wiring the, and wiring the power. Refer to Figure 4. Follow these steps:. Set the baud rate to 9600 baud by placing Switch 6 in the On position. Place all other switches in the Off position. Side B Repeat er J4 J EO L Jumpers Side B (Out) Com D D Com D D REF-OUT N OUT(-) N OUT(+) Side A REF-IN N IN(-) N IN(+) J J Ba ud Ra te Swit ches EO L Jumpers Side A (In) 0 VAC G W N GND LO HI Note: For two twisted pair cable, terminate one pair to (+) and (-), and the other pair to REF. REPEATIN Figure 4: Installing the. Mount the repeater in an enclosure, such as the BZ Mount the enclosure in an appropriate location.. Wire the repeater between two segments of the. If you are using this repeater in a branch, the side with the branch will have double the amount of wires terminated. 4. Connect 0 VAC wires to the repeater. Separate these by two inches from all low voltage wires. For more details on installing the repeater, refer to the manufacturer s literature. Setting the Termination Jumpers End-of-line termination jumpers are used on the PC and Panel Versions of Facilitator, and the repeater. All other devices have self termination. Use these procedures for setting the termination jumpers. Network Communications N Communications Bus

11 For PC Version The termination jumpers for the PC-Version Facilitator are located in the converter (Figure 5). To set the PC as the terminating device, set the jumpers to In by placing them on Pins and of W and W. To set the PC as the non-terminating device, set the jumpers to Out by placing them on Pins and of W and W. RS-to- Converter Jumper Positions: In: - on W and W Out: - on W and W W W CONJUMPR Figure 5: Setting Termination Jumpers for the PC Version For Panel Version The termination jumpers for the Panel-Version Facilitator are located on its circuit board (Figure 6). To set the Panel as the terminating device, set the jumpers to In by placing them on Pins and of W and W4. To set the PC as the non-terminating device, set the jumpers to Out by placing them on Pins and of W and W. Network Communications N Communications Bus

12 Circuit Board in Panel Power LED J J4 N EOL Jumpers In: - on W and W4 Out: - on W and W4 W W4 P RS- Terminal Connector W Microprocessor W P RS- Modem Connector P RS- Printer Connector N LED Diagnostics LED PNLJUMPR Figure 6: Setting the Jumpers for the Panel Version For To set the termination jumpers on the repeater, refer to Table and Figure 4. You need to remove the cover of the repeater to get at the jumpers. Note that sides A and B have separate termination settings. Determine the settings individually. Table : EOL Settings for s SIDE JUMPERS INSTRUCTIONS Side A J and J If at end of line, install both jumpers over pins and (EOL In). If not at end of line, install both jumpers over pins and (EOL Out). If not at end of line and repeater is only switch-terminating device on segment, install both jumpers over pins and (EOL In). Side B J and J4 If at end of line, install both jumpers over pins and (EOL In). If not at end of line, install both jumpers over pins and (EOL Out). If not at end of line and repeater is only switch-terminating device on segment, install both jumpers over pins and (EOL In). 4 Network Communications N Communications Bus

13 Installing the Surge Protectors Surge protection is recommended if the is wired between buildings, especially if your area experiences an above average number of thunderstorms annually. The protection is provided by a voltage surge suppressor, which is installed on the near the first controller. An example application is shown in Figure 7. A S C A S C A S C C P N Surge Protector Surge Protector A S C BUILDNGS Figure 7: Surge Protection Installation on the Network Communications N Communications Bus 5

14 The recommended surge protector is the Transient Eliminator, model TE/JC04C, manufactured by Advanced Protection Technologies (APT). The device protects the from lightning. It shunts both common and normal mode voltage surges to ground repeatedly without damage to components.! CAUTION: The surge protector is capable of protecting the from indirect lightning strikes, not direct lightning strikes. A direct strike may cause actual damage to the bus cable or surrounding property. An indirect lightning strike may cause induced voltage transients that could cause electronic malfunction without visible damage to equipment if the equipment was not protected. Use the surge protector with the standard wiring. Do not use it with any other type wiring, such as leased line. If you need surge protection for other wire types, contact APT or another transient noise protection company for other devices. One surge protector is required at each location where the enters a building from the outside. Unlike some surge protectors, this device does not need to be installed at the entry or exit point of the building. Instead, you should install it close to the first controller that receives the wires from the outside. Also, the protector does not require that you use wire different from the standard wiring, such as double-shielded twisted cable. Follow these installation steps, referring to Figure 8:. Mount the device per local codes and install as close as possible to the controller.. Connect the N segment from the outside to the unprotected side of the device.. Connect the N segment that will go to the controller to the protected side of the device. 4. Connect a AWG stranded green wire from Pin 0 to earth ground, provided the total length of the ground wire does not exceed 5 feet. If total length exceeds 5 feet, mount the suppressor near the location where the enters the building to obtain a better earth ground. 5. For hard ground installation, connect the shield to Pin 9. For soft ground installation, connect the shield to Pin 7 For more details on installation, refer to the manufacturer s literature. 6 Network Communications N Communications Bus

15 UNPROTECTED PROTECTED To surge protector in next building (either or) Hard Ground Soft Ground Hard Ground Soft Ground N REF To earth ground with AWG stranded green wire. To surge protector in next building N REF To ASC Keypin between terminals and Terminal Block on Surge Protector (To wire, remove block from main unit) Note: Mount surge protector as close to the equipment to be protected as possible. Hard ground the at only one location. SURGEWR Figure 8: Installing Surge Protection Device Network Communications N Communications Bus 7

16 8 Network Communications N Communications Bus

MS/TP Communications Bus for the BCProTM System Technical Bulletin

MS/TP Communications Bus for the BCProTM System Technical Bulletin MS/TP Communications Bus for the BCPro TM System Technical Bulletin Code No. LIT-12011908 Issued December 2017 Refer to the QuickLIT website for the most up-to-date version of this document. Document Introduction...3

More information

1993 SPECIFICATIONS CSJ , ETC. & SPECIAL SPECIFICATION ITEM 6132 ARTERIAL TRAFFIC MANAGEMENT SYSTEM

1993 SPECIFICATIONS CSJ , ETC. & SPECIAL SPECIFICATION ITEM 6132 ARTERIAL TRAFFIC MANAGEMENT SYSTEM 1993 SPECIFICATIONS CSJ 1685-05-068, ETC. & 1685-02-042 1.0 DESCRIPTION SPECIAL SPECIFICATION ITEM 6132 ARTERIAL TRAFFIC MANAGEMENT SYSTEM THIS ITEM DESCRIBES THE OPERATION AND INSTALLATION OF AN ARTERIAL

More information

MTII4200 Level Transmitter Installation, Operation & Maintenance Instructions

MTII4200 Level Transmitter Installation, Operation & Maintenance Instructions Specialists in Liquid Level Indication MTII4200 Level Transmitter Installation, Operation & Maintenance Instructions Section: M500 Bulletin: M500.31 Date: 05-17-16 Supersedes: 09-30-11 1. INTRODUCTION

More information

Installation OVERVIEW

Installation OVERVIEW Installation OVERVIEW The DEMCO GATE ACCESS CONTROL SYSTEM is designed to operate up to 4 gates, each with an IN KEYPAD and/or an OUT KEYPAD. Each gate is wired as illustrated in the drawing of a "TYPICAL

More information

Installing the DX LCD Display

Installing the DX LCD Display DX LCD Display User s Guide 3-1 Chapter 3 Installing the DX LCD Display Introduction Use the DX LCD Display as either a portable device, or permanently mount it in a panel or on the wall. For panel and

More information

ControlKeeper 4. General Information. Connecting Relay Loads. Installation Sheet. Getting Started. Power Supply Wiring. Mounting the Cabinet

ControlKeeper 4. General Information. Connecting Relay Loads. Installation Sheet. Getting Started. Power Supply Wiring. Mounting the Cabinet General Information ControlKeeper 4 Installation Sheet Model# CK4-120NO- Model# CK4-277NO The ControlKeeper-4 model is shipped in one package and is configured with either a 120V or a 277V transformer.

More information

Quick Start Installation Guide

Quick Start Installation Guide apc/l Quick Start Installation Guide Version A2 Document Part Number UM-201 May 2010 OVERVIEW The apc/l is an intelligent access control and alarm monitoring control panel which serves as a basic building

More information

Verasys BACnet MS/TP Communications

Verasys BACnet MS/TP Communications Verasys BACnet MS/TP Communications Technical Bulletin Code No. LIT-12012362 Issued February 2017 Refer to the QuickLIT website for the most up-to-date version of this document. Introduction................................................................3

More information

UC-2000 Installation Manual Unicorn Computers Technology Limited

UC-2000 Installation Manual Unicorn Computers Technology Limited UC2000 Installation Manual Copyright 2003. All rights reserved. Table of Contents Specifications 2 Enclosure for the UC2000 Controller 3 Unicorn Access Control System Configuration 4 UC2000 Controller

More information

TB21. NO - Relay. Relay. Common - Relay. NC - Relay. Input J23. Ground TB22 TB23. NO - Relay Common - Relay NC - Relay Input Ground.

TB21. NO - Relay. Relay. Common - Relay. NC - Relay. Input J23. Ground TB22 TB23. NO - Relay Common - Relay NC - Relay Input Ground. NXT x.0 Wiring and Layout Diagrams. NXT-x I/O Module Shielded CAT- Cabling Shielded -Conductor Cabling total cable length 00 feet max (0 m) Brown/Green/Orange w/o Stripe Brown/Green/Orange with Stripe

More information

Connecting a Cisco Output Module

Connecting a Cisco Output Module CHAPTER 5 Overview The optional Cisco Output Module (Figure 5-1) is attached to a Cisco Physical Access Gateway or Cisco Reader Module to provide additional connections for up to 8 outputs, each of which

More information

Secured Series: Hub Plus Kit Single Door Controller Package Installation Manual

Secured Series: Hub Plus Kit Single Door Controller Package Installation Manual Secured Series: Hub Plus Kit Single Door Controller Package Installation Manual This package is designed to simplify the connections to our Secured Series Hub Plus Controller. This will translate into

More information

3710 ACM 3750 PDC 3800 RTU. ISOCOM Communications Card Retrofit Instructions

3710 ACM 3750 PDC 3800 RTU. ISOCOM Communications Card Retrofit Instructions 3710 ACM 3750 PDC 3800 RTU ISOCOM Communications Card Retrofit Instructions Danger During normal operation of this device, hazardous voltages are present which can cause severe injury or death. These

More information

IC System TM Design Guide

IC System TM Design Guide IC System TM Design Guide July 2009 IC System Product Definitions... 3 Central Control Software... 3 ICI... 4 ICM... 5 ICSD... 5 Components of the IC System Interface (ICI)... 6 CPU Board... 6 Driver Board...

More information

MODEL 8000MP LEVEL SENSOR

MODEL 8000MP LEVEL SENSOR 1 MODEL 8000MP LEVEL SENSOR INSTRUCTIONS FOR INSTALLATION, OPERATION & MAINTENANCE VISIT OUR WEBSITE SIGMACONTROLS.COM 2 SERIES 8000MP LEVEL SENSOR 1. DESCRIPTION The Model 8000MP Submersible Level Sensor

More information

205 CPU NETWORK ADAPTER F2-UNICON

205 CPU NETWORK ADAPTER F2-UNICON 205 CPU NEWORK ADAPER F2-UNICON Network Adapter he F2-UNICON Network Adapter is used to place Automationdirect.com DL205 CPUs (except D2-230 and D2-250) on a RS-422 or RS-485 multi-drop network. he Network

More information

VertX. V100, V200 and V300. Installation Guide Barranca Parkway Irvine, CA USA. November Rev A.1

VertX. V100, V200 and V300. Installation Guide Barranca Parkway Irvine, CA USA. November Rev A.1 15370 Barranca Parkway Irvine, CA 92618 USA VertX V100, V200 and V300 Installation Guide November 2011 6080-930 Rev A.1. Contents Introduction... 3 Parts List... 3 Product Specifications... 3 Cable Specifications...

More information

MODELS PD230 AND PD1230 Installation Instructions

MODELS PD230 AND PD1230 Installation Instructions PNEUMERCATOR Liquid Level Control Systems MODELS PD20 AND PD20 Installation Instructions Model PD20 x2 Channel Lightning Surge Protector Model PD20 x2 Channel Lightning Surge Protector COPYRIGHT 2007 PNEUMERCATOR

More information

Control Techniques Variable-Speed Drive (VSD) Interface to E2 v and Above

Control Techniques Variable-Speed Drive (VSD) Interface to E2 v and Above TECHNICAL BULLETIN Part #: 026-4122 Revision 0 Date: 2/5/2007 Control Techniques Variable-Speed Drive (VSD) Interface to E2 v. 2.40 and Overview Beginning with version 2.40, the E2 RX, BX, and CX series

More information

DLS-E2 TELEMETERING UNIT BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL MODEL. (16 contact inputs & 16 open collector outputs)

DLS-E2 TELEMETERING UNIT BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL MODEL. (16 contact inputs & 16 open collector outputs) INSTRUCTION MANUAL TELEMETERING UNIT ( contact inputs & open collector outputs) MODEL DLS-qE DLS-E BEFORE USE... Thank you for choosing M-System. Before use, please check contents of the package you received

More information

MS-4000: ShootingStar Reader

MS-4000: ShootingStar Reader : ShootingStar Reader The ShootingStar Reader The ShootingStar Reader is intended for installation on a solid metal surface, in proximity applications where a vandal-proof reader is required. The reader

More information

Thermometer / Barometer System

Thermometer / Barometer System TBX USER S MANUAL Thermometer / Barometer System 616TA Pg.2of12 TABLE OF CONTENTS QUICK START GUIDE... 3 INTRODUCTION... 6 SPECIFICATIONS... 6 TERMINAL COMPARTMENT LAYOUT... 7 FEATURES... 8 OPERATION...

More information

CS485. User s Manual. Version ZYPEX, Inc.

CS485. User s Manual. Version ZYPEX, Inc. CS485 User s Manual Version 2.0 2003 ZYPEX, Inc. Table of Contents Product Description 1 CS485 Configuration & Setup 2 4-wire Operation 2 2-wire Operation 2 Dual Port Operation 2 Carrier Detect 2 Transmitter

More information

PXL-250 Tiger Controller

PXL-250 Tiger Controller PXL-0 Tiger Controller This quick start guide is made up of specification sheets, a DO/DON T list, basic installation drawings, first time power-on instructions, and short descriptions of key terms and

More information

Model 160. Model 186. Model 247. Surge Protective Devices. Installation & Operation Manual. Model 160. Model 186. Model 247 (EDCO RM-CX06-16R)

Model 160. Model 186. Model 247. Surge Protective Devices. Installation & Operation Manual. Model 160. Model 186. Model 247 (EDCO RM-CX06-16R) Surge Protective Devices Installation & Operation Manual Model 160 (16-Channel Coaxial) Model 186 (16 or 48 Channel Hi Speed Data Line Protector) Model 247 (120VAC Active Tracking Filter) Model 160 (EDCO

More information

COM32. Installation & Operation Manual

COM32. Installation & Operation Manual COM32 Installation & Operation Manual DANGER ElectricaI equipment contains hazardous voltages and high speed moving parts. Can cause death, serious injury or property damage. See safety instruction contained

More information

LN Series Input/Output (I/O) Extension Modules and LN Communicating Sensors Subnetwork for LN-VAVCF-12 and LN-PRGxxx-12 Application Note

LN Series Input/Output (I/O) Extension Modules and LN Communicating Sensors Subnetwork for LN-VAVCF-12 and LN-PRGxxx-12 Application Note LN Series Input/Output (I/O) Extension Modules and LN Communicating Sensors Subnetwork for LN-VAVCF-12 and LN-PRGxxx-12 Application Note LN-IOE400-0, LN-IOE410-0, LN-IOE420-0, LN-VAVCF-12, LN-PRGxxx-12

More information

Installation & Operation Guide

Installation & Operation Guide Installation & Operation Guide (Shown with optional Override Board Cover) KMD-5831 Programmable Loop Controller PLC-28 Direct Digital Controller 902-019-04B 1 Introduction This section provides a brief

More information

INSTRUCTION MANUAL DIGI-LOCK. Keyless Entry System. Installation. Programming. Troubleshooting. BASE Industries

INSTRUCTION MANUAL DIGI-LOCK. Keyless Entry System. Installation. Programming. Troubleshooting. BASE Industries INSTRUCTION MANUAL DIGI-LOCK Keyless Entry System Installation Programming Troubleshooting BASE Industries 45 Pomona Rd. Corona, CA. 9880 Revision F TABLE OF CONTENTS OWNER REGISTRATION CARD INTRODUCTION

More information

EA500. Installation Instructions Transponder

EA500. Installation Instructions Transponder EA500 EN Installation Instructions Transponder EA500 Installation Instructions 1.0 Overview EN 2 1.0 Overview The EA500 Transponder is the Security Escort module that provides communications between the

More information

SERVICE AND INSTALLATION INSTRUCTIONS

SERVICE AND INSTALLATION INSTRUCTIONS MAIN FEATURES INSTRUMENTS, INC. 468 Liberty Drive Wittenberg, WI 54499 U.S.A. SERVICE AND INSTALLATION INSTRUCTIONS EAGLE 2 TEL 715-253-2801 Ver. 04-16-2008 FAX 715-253-2811 www.imcinstruments.com D I

More information

Quick Start Installation Guide

Quick Start Installation Guide istar Pro Quick Start Installation Guide Version B0 Part Number UM-069 January 2005 OVERVIEW This guide defines all of the commonly used connection methods to the istar Pro. It outlines how to wire readers

More information

Rev CH Breaker Gateway Installation and Operation Manual

Rev CH Breaker Gateway Installation and Operation Manual 026-1710 Rev 1 05-15-07 CH Breaker Gateway Installation and Operation Manual 1640 Airport Road, Suite 104 Kennesaw, GA 31044 Phone: (770) 425-2724 Fax: (770) 425-9319 ALL RIGHTS RESERVED. The information

More information

IEI emerge MicroNode Install and Setup Guide. Contents

IEI emerge MicroNode Install and Setup Guide. Contents IEI emerge MicroNode Install and Setup Guide Contents Connecting power and the network to the MicroNode... 2 Using Power over Ethernet (PoE)... 3 or... 3 Using a 12 VDC power supply... 3 Connecting and

More information

FEATURES DESCRIPTION MODEL 110B. Power Supply

FEATURES DESCRIPTION MODEL 110B. Power Supply FEATURES Extends wiring distance of FT-10 LonWorks Networks. (2) channels using a single Model 110B. Up to 10 channels using (5) Model 110B. Low cost alternative to routers configured as repeaters. Wring

More information

Rev Cutler-Hammer Smart Breaker Panel Control Manual

Rev Cutler-Hammer Smart Breaker Panel Control Manual 026-70 Rev 0 6-0-03 Cutler-Hammer Smart Breaker Panel Control Manual 640 Airport Road, Suite 04 Kennesaw, GA 3044 Phone: (770) 425-2724 Fax: (770) 425-939 ALL RIGHTS RESERVED. The information contained

More information

USB to RS-485/RS-422 Interface Converter. User Manual

USB to RS-485/RS-422 Interface Converter. User Manual USB to RS-485/RS-422 Interface Converter User Manual CONTENTS I. Summary 3 II. Functions..3 III. Hardware installment and application... 3 IV. Performance parameters........4 V. Connector and signal.......4

More information

Connecting a Cisco Input Module

Connecting a Cisco Input Module CHAPTER 4 Overview The optional Cisco Input Module (Figure 4-1) is attached to a Cisco Physical Access Gateway or Cisco Reader Module to provide additional connections for up to ten input devices. Each

More information

This Datasheet for the IC670GBI002 24VDC BUS INTERFACE UNIT.

This Datasheet for the IC670GBI002 24VDC BUS INTERFACE UNIT. This Datasheet for the IC670GBI002 24VDC BUS INTERFACE UNIT http://www.qualitrol.com/shop/p-14508-ic670gbi002.aspx Provides the wiring diagrams and installation guidelines for this GE Field Control module.

More information

TCNM-ACBB1 Installation Manual

TCNM-ACBB1 Installation Manual The TCNM-ACBB1 is a connection box that can be used as an accessory to facilitate system connections for installation and device replacement of several Banner family reading devices. System cabling is

More information

USER MANUAL. MODEL 1000P Non-Powered Short Haul Modem. SALES OFFICE (301) TECHNICAL SUPPORT (301)

USER MANUAL. MODEL 1000P Non-Powered Short Haul Modem. SALES OFFICE (301) TECHNICAL SUPPORT (301) USER MANUAL MODEL 1000P Non-Powered Short Haul Modem C E R T I F I E D An ISO-9001 Certified Company Part #07M1000PA Doc. #022031UA Revised 2/17/98 SALES OFFICE (301) 975-1000 TECHNICAL SUPPORT (301) 975-1007

More information

Installing and Setting Up the Components

Installing and Setting Up the Components Chapter 3 Installing and Setting Up the Components This section of the AKC 55 manual will explain, for each network component: (1) Description and Identification (5) Network connections (2) Mounting (6)

More information

DATA CONNECT ENTERPRISE

DATA CONNECT ENTERPRISE DATA CONNECT ENTERPRISE User s Manual IG202T and IGV23 Modem Document Number 520-01005-001 Rev. A DATA CONNECT Contents Contents... iii Figures... iv Chapter 1 Introduction... 5 Features...6 Applications...7

More information

Installation and Operation Guide

Installation and Operation Guide Installation and Operation Guide Network -Isolator Contents Introduction...3 Installation...3 Mounting...3 Wiring and Terminal locks...4 Network Connections...4 Configuration/...7 Power Connection...7

More information

Integrity Instruments Application Notes. Release 1

Integrity Instruments Application Notes. Release 1 Integrity Instruments Application Notes Release 1 What is EIA/TIA/RS-485 What is EIA/TIA/RS-422 Half Duplex and Full Duplex Communication Asynchronous Communicatin Grounding EIA/TIA/RS-485/422 Shielding

More information

Installation & Operation Guide

Installation & Operation Guide Installation & Operation Guide Direct Digital VAV Controllers KMD-7001/7051 - VAV Terminal Units KMD-7002/7052 - Dual Duct VAV Units KMD-7003/7053 - Fan Induction Units 907-019-01C 1 Introduction This

More information

Measure Ø-N, Ø-Ø, Ø-Gnd with voltmeter to confirm application voltage prior to installation.

Measure Ø-N, Ø-Ø, Ø-Gnd with voltmeter to confirm application voltage prior to installation. Product No. 99-600-91 Rev. B Page 1 of 8 MCG Surge Protection Model 160MXT Installation Instructions Important Warranty Information MCG surge protectors are designed to work at specific voltages and configurations,

More information

"PC" Central Access Control System

PC Central Access Control System "PC" Central Access Control System CORPORATION TOY E ACCESS CONTROL SYSTEMS Hardware Guide FIELD LAYOUT OPTIONS The system may be fully controlled by either a personal computer or a "PC" Smart Cartridge.

More information

Overvoltage Protection

Overvoltage Protection Overvoltage Protection Weidmuller has a complete line of overvoltage protection devices to effectively stop the harmful effects of electrical overvoltage and electrical noise. There is strong potential

More information

Suprex RS-485 SPX-7500 Wired Reader-Extender

Suprex RS-485 SPX-7500 Wired Reader-Extender Suprex RS-485 SPX-7500 Wired Reader-Extender Product Manual SPX-7500_MAN_181206 Cypress Integration Solutions 35 Years of Access Control Ingenuity CypressIntegration.com 2018 Cypress Computer Systems 1778

More information

Connecting a Cisco Reader Module

Connecting a Cisco Reader Module CHAPTER 3 Overview The optional Cisco Reader Module (Figure 3-1) is similar to the Cisco Physical Access Gateway, providing the same ports for Weigand readers and other input and output devices. The Cisco

More information

SVP110 SURGE VOLTAGE PROTECTOR INSTRUCTION MANUAL

SVP110 SURGE VOLTAGE PROTECTOR INSTRUCTION MANUAL SVP110 SURGE VOLTAGE PROTECTOR INSTRUCTION MANUAL REVISION: 01/03/03 COPYRIGHT (c) 1995-2000 CAMPBELL SCIENTIFIC, INC. This is a blank page. WARRANTY AND ASSISTANCE The SVP110 SURGE VOLTAGE PROTECTOR is

More information

MD9 MULTIDROP INTERFACE INSTRUCTION MANUAL

MD9 MULTIDROP INTERFACE INSTRUCTION MANUAL MD9 MULTIDROP INTERFACE INSTRUCTION MANUAL REVISION: 01/05/03 COPYRIGHT (c) 1987-2003 CAMPBELL SCIENTIFIC, INC. This is a blank page. WARRANTY AND ASSISTANCE The MD9 MULTIDROP INTERFACE is warranted by

More information

EntraGuard Bronze. Quick Start Guide. Telephone Entry. 1.0 Specifications. 2.0 Unit Installation

EntraGuard Bronze. Quick Start Guide. Telephone Entry. 1.0 Specifications. 2.0 Unit Installation The EntraGuard Bronze is a residential telephone keypad entry system which allows a homeowner to communicate directly with visitors and provide access by using any phone extension in the home. Because

More information

WS115 BREAKOUT ADAPTER USER MANUAL

WS115 BREAKOUT ADAPTER USER MANUAL STATIC WATER LEVEL MEASUREMENT WS115 BREAKOUT ADAPTER USER MANUAL www.enoscientific.com Page 1 Eno Scientific 1606 Faucette Mill Rd Hillsborough, NC 27278 USA www.enoscientific.com 910-778-2660 Copyright

More information

6222 Two Door Module Technical Operations Manual

6222 Two Door Module Technical Operations Manual 6222 Two Door Module Technical Operations Manual TABLE OF CONTENTS Specifications...3 Overview...4 Operations...5 Custom Access Mode...5 Standard Access Mode...5 Offline Access Mode...5 Offline Memory...5

More information

HUBBELL SPIKESHIELD Wired-In Branch Panels Surge Protective Device (SPD)

HUBBELL SPIKESHIELD Wired-In Branch Panels Surge Protective Device (SPD) HUBBELL SPIKESHIELD Wired-In Branch Panels Surge Protective Device (SPD) Instruction Bulletin 8222-0513B Retain for future use. SPIKESHIELD Wired-In Branch Panels 8222-0513B 05/2012 Table of Contents Precautions...

More information

MicroTech Absorption Gateway for Absorption Chillers

MicroTech Absorption Gateway for Absorption Chillers Installation & Maintenance Data IM 620-1 Group: Controls Part Number: 585524Y Date: February 1998 MicroTech Absorption Gateway for Absorption Chillers MicroTech Absorption Gateway MicroTech a0170 1998

More information

Installation Instructions for the AUTOcard-SA System

Installation Instructions for the AUTOcard-SA System Installation Instructions for the AUTOcard-SA System IMPORTANT NOTICE The AUTOcard-SA system is a very reliable and easy to use system. However, damage could occur if it is installed incorrectly. In particular,

More information

The six major components of a structured wiring system are:

The six major components of a structured wiring system are: OBJECTIVES 1. Describe various ANSI/TIA/EIA standards for commercial buildings and residential settings. 2. Discuss the specific Technical Systems Bulletins that can affect telecommunications installations.

More information

CO-485USB USB to RS-485 CONVERTER TECHNICAL REFERENCE

CO-485USB USB to RS-485 CONVERTER TECHNICAL REFERENCE TABLE OF CONTENTS CO-485USB USB to CONVERTER TECHNICAL REFERENCE Specifications, Description and Technical Support... page 1 Connection Diagram... page 2 Set-Up & Testing... page 3 & 4 Power Supply Shunts...

More information

TECHNICAL PRODUCT DATASHEET

TECHNICAL PRODUCT DATASHEET FORM-ENG-0018 REV A 06-02-03 ISO 9001 CERTIFIED Phone: (352) 629-5020 or 800-533-3569 Fax: (352)-629-2902 SUITABLE FOR EXTERNAL DISTRIBUTION TECHNICAL PRODUCT DATASHEET ES-Key Climate Control Module P/N

More information

1. FEATURES AND BENEFITS

1. FEATURES AND BENEFITS Series S i x Programmable Controller GFK-0238A Communications Control Module Type 2 and Type 3 November 1988 IC600CB536 IC600CB537 General Description The Communications Control Module Type 2 (CCM2) and

More information

Installation Notes TII Model 341 Protector

Installation Notes TII Model 341 Protector Installation Notes TII Model 341 Protector (ATT-IS PEC 32918) for MERLIN Communications System In Range Out of Building (IROB) Station Installation By Trained Technician Only WARNING: Failure to follow

More information

Installation and Setup

Installation and Setup Installation and Setup 1 In This Chapter Installing the H PBC The Profibus Network Configuring the Controller Installing the H PBC Setting the Node Address Setting the Node Address Profibus DP is usually

More information

MANUAL INSTALLATION. Multi-Variable Monitor. MVM Series. Issue Date: 02/07/ Price Industries Limited. All rights reserved.

MANUAL INSTALLATION. Multi-Variable Monitor. MVM Series. Issue Date: 02/07/ Price Industries Limited. All rights reserved. MANUAL INSTALLATION Multi-Variable Monitor MVM Series Issue Date: 02/07/18 2018 Price Industries Limited. All rights reserved. TABLE OF CONTENTS Product Overview General...1 MVM Specifications...1 Included

More information

115/230 VAC Digital Input Module OHDI-01

115/230 VAC Digital Input Module OHDI-01 Drive IT Low Voltage AC Drives User s Manual 115/230 VAC Digital Input Module OHDI-01 OHD4 2 115/230 VAC Digital Input Module OHDI-01 Safety WARNING! All electrical installation and maintenance work on

More information

BACnet Flow Controller for Fan Filter Units

BACnet Flow Controller for Fan Filter Units MANUAL SERVICE + INSTALLATION BACnet Flow Controller for Fan Filter Units BFC Series v300 Issue Date: 08/23/17 2017 Price Industries Limited. All rights reserved. TABLE OF CONTENTS Product Overview General

More information

MS-7000: SuperStar Reader

MS-7000: SuperStar Reader The MS-7000 SuperStar Reader The MS-7000 SuperStar Reader is intended for installation in proximity applications where an extended read range is required. The reader provides an audio beeper and a multi

More information

Surgelogic Surge Protective Devices LC, XR, and XW Series

Surgelogic Surge Protective Devices LC, XR, and XW Series Surgelogic Surge Protective Devices LC, XR, and XW Series Catalog 1311CT0101R6/07 2007 Class 1311 CONTENTS Description..............................................Page Product Description...........................................

More information

4100/4120-Series Class A / Class B Zone Modules Installation Instructions

4100/4120-Series Class A / Class B Zone Modules Installation Instructions 4100/4120-Series Class A / Class B Zone Modules Installation Instructions Introduction This publication describes the installation procedure for the following modules. Model Description Required Back Box

More information

MODEL DRIVER Ic Ip VDC

MODEL DRIVER Ic Ip VDC Provides Mounting & Connections for Stepnet Module CANopen Stepping Driver FEATURES Develop & Debug Stepnet projects then transfer design to OEM pc board. MODEL DRIVER Ic Ip VDC -075-01 STM-075-07 5 7

More information

High Power over Ethernet Midspans PD Port Model PD Port Model

High Power over Ethernet Midspans PD Port Model PD Port Model Data and Power on a Single Line High Power over Ethernet Midspans PD-8006-6 Port Model PD-8012-12 Port Model User Guide Notice The information contained herein is believed to be accurate and reliable at

More information

SECURA KEY CARD ACCESS CONFIGURATION GUIDE Multi-Reader Systems with NOVA.16 (SK-MRCP) 16-Door Panel

SECURA KEY CARD ACCESS CONFIGURATION GUIDE Multi-Reader Systems with NOVA.16 (SK-MRCP) 16-Door Panel SECURA KEY CARD ACCESS CONFIGURATION GUIDE Multi-Reader Systems with (SK-MRCP) -Door Panel WITH RS- GATEWAY CONNECTED DIRECTLY TO A PC RS- GATEWAY POWER: EIGHT (8) SMART READERS EVENLY SPACED UP TO 000

More information

HyperLink Brand Weatherproof PTZ Camera Lightning and Surge Protector Model: AL-VDP Series

HyperLink Brand Weatherproof PTZ Camera Lightning and Surge Protector Model: AL-VDP Series HyperLink Brand Weatherproof PTZ Camera Lightning and Surge Protector Model: AL-VDP Series Applications Pan-Tilt-Zoom (PTZ) analog video cameras Features Individual protection circuits for analog video

More information

Operating Instructions

Operating Instructions Introduction To protect the signal lines of field devices and systems in the cabinet against lightning. Pepperl+Fuchs covers the complete range of Surge Protection Barriers. Housing types Depending on

More information

Optical Multiplexer. Quick Start Guide

Optical Multiplexer. Quick Start Guide Optical Multiplexer Quick Start Guide Part Number: 07M1195-QS, Rev. A Revised: February 12, 2009 Sales Office: +1 (301) 975-1000 Technical Support: +1 (301) 975-1007 E-mail: support@patton.com WWW: www.patton.com

More information

DIN Molded Cable Assemblies

DIN Molded Cable Assemblies DIN 43650 Telephone (973) 586-500 FAX (973) 596-590 DIN 43650 8mm For Solenoid Valve Applications Black PVC Cable & Connector DUAL JUMPED GROUND PINS Molded cable assemblies can be mounted with cable exiting

More information

MS-5000: MiniStar Reader

MS-5000: MiniStar Reader The MS-5000 MiniStar Reader The MS-5000 MiniStar Reader is intended for installation in a single gang electrical "J-Box," in proximity applications where an unobtrusive reader is required. It can also

More information

Telephony Multi-Taps. 9000T-TP Series

Telephony Multi-Taps. 9000T-TP Series 9000T-TP Series The 9000T-TP series 1 GHz twisted-pair power multi-tap taps off part of its input RF and AC, but lets the rest pass through. It divides the tapped-off signal and power into multiple outputs,

More information

SP SP-T-9

SP SP-T-9 INSTALLATION INSTRUCTIONS Revision B1 Rapid City, SD, USA, 04/2010 MODELS 201-100-SP 201-200-SP 201-200-SP-T-9 II_201-SP_B1 2880 North Plaza Drive, Rapid City, South Dakota 57702 (800) 843-8848 (605) 348-5580

More information

genesis TECHNICAL MANUAL Two-Door Controller GEN-045

genesis TECHNICAL MANUAL Two-Door Controller GEN-045 Two-Door Controller GEN-045 Genesis Electronics Australia Pty Ltd www.genesiselectronics.com.au info@genesiselectronics.com.au Australian Owned, Designed and Manufactured Distributed By:- Genesis reserves

More information

Code Dynamics, Inc. Port Splitter

Code Dynamics, Inc. Port Splitter Code Dynamics, Inc. Port Splitter Thank you for purchasing the Port Splitter. With this product, you can utilize a single Andover port for both the modem and PC connections. This device connects to the

More information

Installing the Cisco AS5400XM Universal Gateway

Installing the Cisco AS5400XM Universal Gateway CHAPTER 3 Installing the Cisco AS5400XM Universal Gateway This chapter guides you through the installation of the Cisco AS5400XM universal gateway and includes the following sections: Setting Up the Chassis,

More information

ECL Comfort 296 / 310 controllers Modbus networking guide

ECL Comfort 296 / 310 controllers Modbus networking guide Service Guide ECL Comfort 296 / 310 controllers Modbus networking guide 1.0 Contents 1.0 Contents......1 2.0 Introduction...2 3.0 Conclusion...2 4.0 Modbus network definitions...3 4.1 Multipoint serial

More information

Two Door Controller GEN-045

Two Door Controller GEN-045 Australian Owned, Designed and Manufactured Two Door Controller GEN-045 Genesis Electronics Australia Pty Ltd www.genesiselectronics.com.au Distributed by: Genesis reserves the right to change or modify

More information

Vorne Industries. Model 77/232 Serial Input Numeric 3" Display User's Manual

Vorne Industries. Model 77/232 Serial Input Numeric 3 Display User's Manual Vorne Industries Model 77/232 Serial Input Numeric 3" Display User's Manual 1445 Industrial Drive Itasca, IL 60143-1849 (630) 875-3600 Telefax (630) 875-3609 Page 2 Model 77/232 Serial Input Numeric 3"

More information

MS-3000 MicroStar Reader

MS-3000 MicroStar Reader MicroStar Reader The MicroStar Reader The MicroStar Reader is intended for installation on a window mullion or a door frame, on or off metal, in proximity applications where an unobtrusive reader is required.

More information

Disclaimer. Note that the Midspan is designed for indoor use only.

Disclaimer. Note that the Midspan is designed for indoor use only. Gigabit Power over Ethernet Midspans PD-6006G, PD-6012G & PD-6024G 6/12/24-Port Models IEEE 802.3af-compliant User Guide Notice The information contained herein is believed to be accurate and reliable

More information

Switching Control Sentinel (SCS) TM For all ABB independent pole operated circuit breakers

Switching Control Sentinel (SCS) TM For all ABB independent pole operated circuit breakers Switching Control Sentinel (SCS) TM For all ABB independent pole operated circuit breakers Switching Control Sentinel (SCS) for circuit breakers Voltage and current transients generated during switching

More information

Digital Lighting Systems, Inc. PD216. Two Channel Dimmer and Switch Packs PROTOCOL USER'S MANUAL. PD216-UM Rev. E - 02/03

Digital Lighting Systems, Inc. PD216. Two Channel Dimmer and Switch Packs PROTOCOL USER'S MANUAL. PD216-UM Rev. E - 02/03 Digital Lighting Systems, Inc. PD26 Two Channel Dimmer and Switch Packs PROTOCOL PD26 S2 S USER'S MANUAL PD26-UM Rev. E - 02/03 Digital Lighting Systems PD26 User's Manual - Page GENERAL DESCRIPTION The

More information

CardMaster Installation Manual rev NE 177th Place, Woodinville, WA fax

CardMaster Installation Manual rev NE 177th Place, Woodinville, WA fax CardMaster Installation Manual 11.05.30 rev 1 13450 NE 177th Place, Woodinville, WA 98072 www.cardlockvending.com 888-487-5040 fax 425-487-6644 3.0 Critical Do s and Don'ts Do not proceed without reading

More information

PREVENTING DOWNTIME OF E911 CENTERS

PREVENTING DOWNTIME OF E911 CENTERS P O W E R V A R White Paper # 600 PREVENTING DOWNTIME OF E911 CENTERS 1 4 5 0 L a k e s i d e D r i v e, Wa u k e g a n, I l l i n o i s 6 0 0 8 5 t e l e p h o n e : 8 4 7-5 9 6-7 0 0 0 f a x : 8 4 7-5

More information

N2 Dialer Module. Features and Benefits

N2 Dialer Module. Features and Benefits Metasys Network Sales Resource Manual 635 Application Specific Controllers Section Product Bulletin Issue Date 1194 N2 Dialer Module The N2 Dialer Module (NDM) provides a low-cost method of connecting

More information

Classic Brain Boards. Classic Brain Boards. Features. Description. Networking. Part Numbers

Classic Brain Boards. Classic Brain Boards. Features. Description. Networking. Part Numbers B2 Analog Brain Board Features Intelligent digital processors. Serial data link operates at selectable baud rates from 300 baud to 38.4 Kbaud Optomux units can be configured for either multidrop or repeat

More information

FX-2 Control Board ASY-360-XXX Setup and Configuration Guide

FX-2 Control Board ASY-360-XXX Setup and Configuration Guide FX-2 Control Board ASY-360-XXX Setup and Configuration Guide Micro Air Corporation Phone (609) 259-2636 124 Route 526. WWW.Microair.net Allentown NJ 08501 Fax (609) 259-6601 Table of Contents Introduction...

More information

R1M-GH BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL PC RECORDER MODEL. (thermocouple or DC input, 16 points)

R1M-GH BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL PC RECORDER MODEL. (thermocouple or DC input, 16 points) INSTRUCTION MANUAL PC RECORDER (thermocouple or DC input, points) MODEL BEFORE USE... Thank you for choosing M-System. Before use, please check contents of the package you received as outlined below. If

More information

CDN502 HIGH DENSITY I/O ADAPTER USER GUIDE

CDN502 HIGH DENSITY I/O ADAPTER USER GUIDE CDN502 HIGH DENSITY I/O ADAPTER USER GUIDE 13050201 (c) Copyright DIP Inc., 1996 DIP Inc. P.O. Box 9550 MORENO VALLEY, CA 92303 714-924-1730 CONTENTS DN502 PRODUCT OVERVIEW 1 DN502 INSTALLATION 1 POWER

More information

STATE OF NEW JERSEY BUREAUS OF ITS ENGINEERING AND SAFETY & DATA DEVELOPMENT DEPARTMENT OF TRANSPORTATION TRENTON, NEW JERSEY 08625

STATE OF NEW JERSEY BUREAUS OF ITS ENGINEERING AND SAFETY & DATA DEVELOPMENT DEPARTMENT OF TRANSPORTATION TRENTON, NEW JERSEY 08625 September 2011 STATE OF NEW JERSEY BUREAUS OF ITS ENGINEERING AND SAFETY & DATA DEVELOPMENT DEPARTMENT OF TRANSPORTATION TRENTON, NEW JERSEY 08625 MATERIAL SPECIFICATIONS FOR WEIGH-IN-MOTION SYSTEM The

More information

LED MOVING HEAD FLEX BEAM K8 RGBW. User Manual. Please read the instruction carefully before use

LED MOVING HEAD FLEX BEAM K8 RGBW. User Manual. Please read the instruction carefully before use LED MOVING HEAD FLEX BEAM K8 RGBW 1 User Manual Please read the instruction carefully before use CONTENTS 1. Safety Instructions... 3 2. Technical Specifications... 4 3. How To Set The Unit... 5 3.1 Front

More information