Infrastructure for the Architecture

Size: px
Start display at page:

Download "Infrastructure for the Architecture"

Transcription

1 Infrastructure for the Architecture Creating an electrical infrastructure that maximizes the reliability of your critical control circuits Component Solutions - Ethernet Network Power Solutions Technology Advancements As technology continues to evolve Ethernet networks are moving to the plant floor and equipment that was commonly used in the IT Server room is migrating to components within the industrial control cabinet. Network information is critical and maintaining power to the network will help insure that the information is successfully and reliably delivered. This document discusses strategies to maintain the integrity of network power within a harsh industrial environment. Application Issues Maintaining reliable network power was relatively easy in the IT server room. The atmosphere was clean, environmentally controlled and free of electrical noise and transients, typically the only additional component used was a Uninterruptible Power Supply (UPS). Now consider the manufacturing floor, components are typically operating under strenuous power and environment conditions resulting in a higher risk of component failure which could result in the unexpected shutdown of the Network. If the network power supply reaches end of life or happens to fail for any other reason, it is desirable to continue operating the networks until a planned shutdown when maintenance can be performed. Reliable and consistently available power to the network can be accomplished by design of the power supply circuit using redundancy, UPS and surge/filter products. It should be noted that there is a distinct difference between Rockwell Industrial UPS s products versus the common Commercial grade UPS products. The industrial UPS is specifically designed to meet the requirements of the strenuous power and environment conditions seen in an industrial application. Such as the ability to remotely turn on/off, easily replace batteries, hardwired input and output, dry-contacts to provide status to PLC or stack light, operate in high ambient temperatures and designed to easily install into an industrial control panel. These are features of an Industrial UPS that are not consistent with the typical commercial grade UPS products. Network Power Solutions Industrial Ethernet switches used on the plant floor are designed for 24VDC input power (typically control power) and typically require the use of a Class 2 power supply or a low-voltage limited energy circuit. NEC Class 2 circuit considers safety from a fire initiation standpoint and provides acceptable protection from electrical shock. The low voltage limited energy circuit requires that the open-circuit voltage does not exceed 42.4 Vdc and have an overcurrent protection of 5 amps 2. The concern of maintaining network power for critical applications can be most directly addressed with a redundant system. The redundancy can be achieved either by the Ethernet switch (Stratix 8000), two separate and isolated inputs for redundant power sources, or through the external power source that is supplying the Ethernet switch. In the case of the loss of power there is another solution that should be considered. When there is a loss of power, the Ethernet switch will power down unless precautions are taken. This is where the use of an industrial UPS will provide the ability to maintain power to the Ethernet switch and possibly other components inside the panel. With the use of a UPS, power to the network will still be available allowing ride-thru for short disruptions or an orderly shutdown for longer disruptions. There are more details describing each solution in the following Figures. Network Power Solutions Using Redundancy Redundant power is more than simply operating multiple power supplies in a parallel configuration. In the event one power supply fails with shorted outputs, it would trip the circuit protection of the other (redundant) power supply. To guard against this, a redundancy module is also needed that will allow isolation of the power supply outputs. Therefore a single fault failure of any power supply will not cause an interruption in network power This feature is not found on standard power supplies and many manufacturers do not provide a dedicated redundant power supply. The layout of a redundant system can be found in Figure 2 and Figure 2. Reference National Electrical Code Article 725 for more information 2 Reference UL508A for more information

2 Redundant Power for Single Input Ethernet Switches (Stratix 2000 or 6000) Note that in this solution the Stratix 2000 and Stratix 6000 do not have built in redundancy within the switch. Therefore the use of the redundancy module is to provide protection from each of the NEC Class 2 power supplies in the event that one of the power supplies fail. In this particular solution the 24VDC power is maintained to the Stratix in the event that one of the power supplies fail. There also is a set of dry contacts that will change state to indicate that the other power supply has failed and could be used to provide feedback to the controller or to turn on a signal light. This solution helps with the customer that is looking to add some level of reliability to their Network system. The addition of the surge protection device in front of the power supplies provides additional reliability by protecting the power supply in the event of surges seen by the 20V AC line. Figure 20V AC 606-XLERED 783-EMS08T 4983-DS20-40 Redundant Power for Dual Input Ethernet Switches (Stratix 8000) In this solution using the Stratix 8000 the redundancy module is built within the switch and provides isolation to the two separate power sources. Again the addition of the surge protection device in front of the power supplies provides additional reliability by protecting the power supply in the event of surges seen by the 20VAC line. Figure 2 20V DC 783-MS0T 4983-DC The surge devices displayed in the Figure is an example of a surge and surge with filter devices. The individual customer application will determine the selection of the appropriate surge product.

3 Network Power Solutions Using Back-Up Power Back-up is accomplished by using an industrial Uninterruptible Power Supply (UPS). This power source could be 20VAC or 24VDC depending on the particular application. The common components that are backed up are PLCs, Industrial Computer, HMI (Human Machine Interface), Power Supplies and any components that are a part of your control panel. Network switches have also become an essential component to industrial control cabinets. Recommended components for Back-up power to the Stratix Network switch can be found below in Figures 3 & 4. Back-Up AC-Voltage Power for Single Input Ethernet Switches (Stratix 2000 and 6000) In this solution the system is backed up by an industrial AC UPS. In the Figure below the power supply is powered by the UPS. Therefore in the event of an AC Mains power loss the power supply will still maintain AC power to provide the 24VDC to the Ethernet switch. This scenario is most likely used when a customer has a variety of equipment which needs to have back-up power. For example, in a typical panel may have a PLC, HMI screen and Industrial computer that is communicating through the Ethernet network and it is critical to maintain power to each of these components. However, there are other applications that may only require the 24VDC power to be maintained and customer could use a DC UPS. The DC UPS solution is described below in Figure 4. Figure V AC 609-U500NS 783-EMS08T Back-Up DC-Voltage Power for Dual Input Ethernet Switches (Stratix 8000) In this solution the use of the Stratix 8000 and DC UPS provides the ability to maintain power to the 24VDC control. This example is shown using a limited low-voltage energy circuit (refer to UL508A Control Circuits section 43 & 44). The power supply is certified as a SELV (Safety Extra Low Voltage) device, the UPS in combination with the fuse conforms to a low-voltage limited energy circuit with a maximum overcurrent device of 5 amps. Surge & Filter Figure 4 DC UPS 492 -H5 24VDC 783-MS0T 4983-DC XLS240-UPS 492-H5 606-XLS The surge devices displayed in the Figure is an example of a surge and surge with filter devices. The individual customer application will determine the selection of the appropriate surge product. 2 Note that the Surge & Filter capability is built into the UPS. 3

4 Network Power Solutions Using Redundancy, Back-Up Power and Surge& Filter The optimal solution is to utilize both Redundant DC Power sources and Back-Up power. With this type of solution the customer can maintain power to the Stratix switch during a loss of AC power as well as a failure with the DC power source. The layouts below describe solutions that combine both the redundant and back-up solutions which were discussed in the previous figures. Figure 5 AC UPS 2 20V AC Redundancy Module 606-XLERED 783-EMS08T 609-U500NS Figure 6 AC UPS MS0T 609-U500NS 2 Note that the Surge & Filter capability is built into the UPS. 4

5 20V AC Redundancy Module DC UPS 492 -H5 606-XLERED 783-EMS08T 4983-DS XLS240-UPS 492-H5 606-XLS Figure 7 - Integrated Back-UP and Redundant Power with DC UPS 20V AC DC UPS 492 -H5 783-MS0T Surge & Filter 4983-DC XLS240-UPS 606-XLS 492-H5 Figure 8 - Integrated Back-UP and Redundant Power with DC UPS Conclusion Maintaining reliable power to critical control and communication systems requires careful design consideration and product selection. Application of redundancy, back-up power and surge-filter products can be applied to provide increased levels of protection against supply power disruptions. The surge devices displayed in the Figure is an example of a surge and surge with filter devices. The individual customer application will determine the selection of the appropriate surge product. 5

6 Allen-Bradley, Rockwell Software, and Rockwell Automation are trademarks of Rockwell Automation Inc. Publication 606-AT00B-EN-P January 20 Copyright 20 Rockwell Automation, Inc. All Rights Reserved. Printed in USA.

PREVENTING DOWNTIME OF E911 CENTERS

PREVENTING DOWNTIME OF E911 CENTERS P O W E R V A R White Paper # 600 PREVENTING DOWNTIME OF E911 CENTERS 1 4 5 0 L a k e s i d e D r i v e, Wa u k e g a n, I l l i n o i s 6 0 0 8 5 t e l e p h o n e : 8 4 7-5 9 6-7 0 0 0 f a x : 8 4 7-5

More information

Electrical Demand Specification (Reference SOP: )

Electrical Demand Specification (Reference SOP: ) Project: Equipment Description: Location: Equipment No.: Project No: Protocol No.: Content Index 1. GENERAL...3 Design Standards...3 1.1. Standards...3 2. DESIGN...3 2.1. Safety...3 2.2. Circuit protection...3

More information

Product Overview. PowerFlex 520-Series AC Drives Feature. Modular Design. Packaging and Mounting. Optimized Performance

Product Overview. PowerFlex 520-Series AC Drives Feature. Modular Design. Packaging and Mounting. Optimized Performance Product Overview The PowerFlex 520-Series AC drive delivers an innovative design that is remarkably versatile and can accommodate systems ranging from standalone machines to simple system integration.

More information

Redundant Power Supplies. Keep Machines Up When Power Goes Down

Redundant Power Supplies. Keep Machines Up When Power Goes Down Redundant Power Supplies Keep Machines Up When Power Goes Down When your operation is critical, you need power you can count on. Redundant Power Systems are ideal for any equipment where the highest attainable

More information

Line reactors SINAMICS. SINAMICS G120P Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation 4

Line reactors SINAMICS. SINAMICS G120P Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation 4 Safety information 1 General 2 SINAMICS SINAMICS G120P Mechanical installation 3 Electrical installation 4 Technical specifications 5 Operating Instructions Control version V4.6 11/2013 A5E32845290B AA

More information

PanelView Plus/VersaView CE Terminals and Display Modules

PanelView Plus/VersaView CE Terminals and Display Modules Installation Instructions PanelView Plus/VersaView CE Terminals and Display Modules (Catalog Numbers 2711P-xxxxxx, 6182H-xxxxxx) English Inside: Overview...2 For More Information...2 Modular Components...3

More information

Higher Availability: Self-diagnostics. Automatically tests unit electronics and batteries. Designed to simplify maintenance and troubleshooting.

Higher Availability: Self-diagnostics. Automatically tests unit electronics and batteries. Designed to simplify maintenance and troubleshooting. UPS operation and display panel can rotate 90 degrees, which provides upright viewing for users. Liebert GXT3 UPS Includes These Outstanding Features: Flexibility: Rack/tower configuration. The versatile

More information

Power Quality. The Overlooked Productivity Variable

Power Quality. The Overlooked Productivity Variable Power Quality The Overlooked Productivity Variable Up to 70 percent of unexplained downtime is caused by power quality problems. Chances are that your facility is affected Have you experienced unexplained

More information

Allen-Bradley Drives

Allen-Bradley Drives (Cat. No. 1771-IE) Product Data The Analog Input Module (8-bit) (cat. no. 1771-IE) measures analog signals at its inputs and converts this data to 3-digit BCD values (0-255) for transfer to a PC processor.

More information

PowerFlex 750-Series AC Drives

PowerFlex 750-Series AC Drives PowerFlex -Series AC Drives Cost-effective Solution Designed for Ease of Use, Integration & Application Flexibility. The Allen-Bradley PowerFlex -Series of AC Drives is aimed at maximizing your investment

More information

CompactBlock Guard I/O EtherNet/IP Safety Modules

CompactBlock Guard I/O EtherNet/IP Safety Modules Installation Instructions CompactBlock Guard I/O EtherNet/IP Safety Modules Catalog Numbers 1791ES-IB8XOBV4, 1791ES-IB16 Topic Page Important User Information 2 North American Hazardous Location Approval

More information

MAJOR VA Power Inverter

MAJOR VA Power Inverter MAJOR500-500 VA Power Inverter The Major500 is a highly reliable, telecom quality, DC to AC power inverter. The Major500 features full electronic protection, high efficiency and low output noise. The built-in

More information

Tel: AC Power for Business-Critical Continuity TM

Tel: AC Power for Business-Critical Continuity TM Tel: +852-2690-4118 AC Power for Business-Critical Continuity TM Anticipating Technology Changes Through Adaptive Architecture Today, you need a power infrastructure that can work across your enterprise

More information

The PCI Series. Precise power control for complex SCR applications. Phase Angle Fired SCR Power Controls AMPS VAC

The PCI Series. Precise power control for complex SCR applications. Phase Angle Fired SCR Power Controls AMPS VAC The PCI Series Phase Angle Fired SCR Power Controls 25-1200 AMPS 120-600 VAC Precise power control for complex SCR applications. ROBICON 1996 Distributed Worldwide by www.mcgoff-bethune.com Applications

More information

Documentation Supplement for Marine Smart-UPS SRT5KRMXLIM, SRT6KRMXLIM External Battery Pack SRT192RMBPM

Documentation Supplement for Marine Smart-UPS SRT5KRMXLIM, SRT6KRMXLIM External Battery Pack SRT192RMBPM Documentation Supplement for Marine Smart-UPS SRT5KRMXLIM, External Battery Pack SRT192RMBPM Product Description The information in this documentation supplement applies to specific APC by Schneider Electric

More information

Technical Requirements for High-voltage DC Power Feeding Interfaces of ICT equipment

Technical Requirements for High-voltage DC Power Feeding Interfaces of ICT equipment Technical Requirements for High-voltage DC Power Feeding Interfaces of ICT equipment TR No. 176002 1.1.EDITION April 1st, 2015 Nippon Telegraph and Telephone Corporation Introduction This document describes

More information

POWERSOLVE ELECTRONICS LTD PSL400-XX series Conduction Cooled Power Supply Engineering Specification

POWERSOLVE ELECTRONICS LTD PSL400-XX series Conduction Cooled Power Supply Engineering Specification POWERSOLVE ELECTRONICS LTD PSL400-XX series Conduction Cooled Power Supply Engineering Specification 1. Scope 2. Electrical Specification 2.1. AC Input Requirements 2.1.1. Input Voltage 2.1.2. Input Frequency

More information

Installation and Wiring

Installation and Wiring Wiring 2 2 Plan for Safety Safety Techniques WARNING: Providing a safe operating environment for personnel and equipment is your responsibility and should be your primary goal during system planning and

More information

SMARTONLINE E3 UPS SYSTEMS

SMARTONLINE E3 UPS SYSTEMS SMARTONLINE E3 UPS SYSTEMS Extremely efficient protection for your most important equipment IDEAL OUTPUT POWER PROTECTS CRITICAL SYSTEMS On-line, double conversion operation continuously delivers precision-regulated,

More information

output devices. connected to the controller. data communications link. relay systems. user program. MECH1500Quiz1ReviewVersion2 Name: Class: Date:

output devices. connected to the controller. data communications link. relay systems. user program. MECH1500Quiz1ReviewVersion2 Name: Class: Date: Class: Date: MECH1500Quiz1ReviewVersion2 True/False Indicate whether the statement is true or false. 1. The number and type of I/Os cannot be changed in a fixed PLC. 2. In a PLC system, there is a physical

More information

Model HM-535 Power Supply Installation and Service Instructions

Model HM-535 Power Supply Installation and Service Instructions Model HM-535 Power Supply Installation and Service Instructions 430-535 0104 2004 Heritage MedCall, Inc SENTRY INSTALLATION & SERVICE INSTRUCTIONS POWER SUPPLY UNIT Model HM-535 IMPORTANT SAFETY INSTRUCTIONS

More information

(Cat. No P4 and 1777-P4)

(Cat. No P4 and 1777-P4) (Cat. No. 1772-P4 and 1777-P4) Product Data The 1772-P4 and 1777-P4 power supplies provide DC power for the logic circuits in PLC-2 family programmable controllers. These power supplies can accept a power

More information

RT12-240V/2.4kW Rectifier Specification

RT12-240V/2.4kW Rectifier Specification The RT12-240V/2.4kW is a switched mode rectifier (SMR) module that delivers up to 2.4kW of output power (and up to 11A output current) into a 240V nominal DC system. The RT12 suits AC supply voltages between

More information

RT4B-110V/12A RECTIFIER

RT4B-110V/12A RECTIFIER The RT4B-110V/12A is a switched mode rectifier (SMR) module designed to provide up to 12A of output current into a 110V nominal system. It can be used with or without a cooling fan. With a fan it runs

More information

RT4F-120V/20A-WAC RECTIFIER

RT4F-120V/20A-WAC RECTIFIER The RT4F-120V/20A-WAC is a switched mode rectifier/charger module designed to provide up to 20A of output current into a 120V nominal system. This charger has been designed for use in conjunction with

More information

How Power Problems Affect PLC Reliability

How Power Problems Affect PLC Reliability White Paper How Power Problems Affect PLC Reliability Michael A. Stout Vice President of Engineering Falcon Electric, Inc. www.falconups.com 2014 Falcon Electric, Inc. How Power Problems Affect PLC Reliability

More information

Who Needs Remote Power Management for Power Distribution, Power Measurement and Power Control of 48 VDC Equipment?

Who Needs Remote Power Management for Power Distribution, Power Measurement and Power Control of 48 VDC Equipment? Who Needs Remote Power Management for Power Distribution, Power Measurement and Power Control of 48 VDC Equipment? A Network Power Management White Paper Who Needs Remote Power Management for Power Distribution,

More information

APC Matrix-UPS 3kVA 208V/240V In 120/208/240V Out

APC Matrix-UPS 3kVA 208V/240V In 120/208/240V Out APC Matrix-UPS 3kVA 208V/240V In 120/208/240V Out APC Matrix-UPS, 2250 Watts / 3000 VA,Input 208V / Output 120V, 208V, Interface Port DB-9 RS-232, SmartSlot, Extended runtime model Includes: CD with software,

More information

PowerFlex 40 Sample Specification

PowerFlex 40 Sample Specification PowerFlex 40 Sample Specification GENERAL REFERENCES REGULATORY REQUIREMENTS Designed to meet the following specifications: NFPA 70 - US National Electrical Code NEMA ICS 3.1 - Safety standards for Construction

More information

CompactLogix Power Supplies Specifications

CompactLogix Power Supplies Specifications Technical Data CompactLogix Power Supplies Specifications 1768 CompactLogix Power Supplies Catalog Numbers 1768-PA3, 1768-PB3 1769 Compact I/O Power Supplies Catalog Numbers 1769-PA2, 1769-PB2, 1769-PA4,

More information

Ground Fault Current Protection Devices Prevent Costly Production Shutdowns

Ground Fault Current Protection Devices Prevent Costly Production Shutdowns Ground Fault Current Protection Devices Prevent Costly Production Shutdowns Figure.1 Altech s three new series deliver multiple capabilities. In all three series, ground fault sensitivity levels range

More information

Overview. Applications. Benefits. Ordering Information. Sensors OHD Thermal Guard

Overview. Applications. Benefits. Ordering Information. Sensors OHD Thermal Guard Sensors OHD Thermal Guard Overview The OHD Thermal Guard is developed for thermal problem countermeasures and safety standard conformity, which are becoming increasingly important for electronic devices

More information

Applying branch circuit breakers and supplementary protectors in North America

Applying branch circuit breakers and supplementary protectors in North America Product Application AP01102005E WMZT WMZS Applying branch circuit breakers and supplementary protectors in North America Introduction Eaton offers two types of miniature circuit breakers for use in North

More information

Surge & Filter Protection Addressing your industrial power quality needs.

Surge & Filter Protection Addressing your industrial power quality needs. Surge & Filter Protection Addressing your industrial power quality needs. BULLETIN 983 INTRODUCING SURGE & FILTER PROTECTION SURGE & FILTER PROTECTION Rockwell Automation is pleased to introduce the Bulletin

More information

Liebert GXT3 5kVA-10kVA UPS Compact UPS Systems For High Power Network Rack Applications. AC Power For Business-Critical Continuity

Liebert GXT3 5kVA-10kVA UPS Compact UPS Systems For High Power Network Rack Applications. AC Power For Business-Critical Continuity Liebert GXT3 5kVA-10kVA UPS Compact UPS Systems For High Power Network Rack Applications AC Power For Business-Critical Continuity Liebert GXT3, 5kVA-10kVA UPS Systems: Big Protection, Small Package Today

More information

Chassis Power Supplies

Chassis Power Supplies PDC24 / PAC Chassis Power Supplies (PDC24 / PAC) Issue 3 October 2005 INTRODUCTION PURPOSE Two Power Supply Units (PSUs) provide a dual-redundant source of 5.4Vand 12Vdc onto the backplane for the modules

More information

ADVANCED TECHNICAL MANUAL AAC1 SMALL SYSTEM CONTROL CONSOLE. Redefine your comfort zone.

ADVANCED TECHNICAL MANUAL AAC1 SMALL SYSTEM CONTROL CONSOLE. Redefine your comfort zone. ADVANCED TECHNICAL MANUAL AAC1 SMALL SYSTEM CONTROL CONSOLE ATM ACC1 Table of Contents Safety Precautions... 3 Overview... 4 Specifications... 4 Installation... 5 Control Console Operation... 9 2 Advanced

More information

Configurable Output Distribution. 120V / 208V / 240V 60Hz. User Manual English

Configurable Output Distribution. 120V / 208V / 240V 60Hz. User Manual English Configurable Output Distribution 120V / 208V / 240V 60Hz User Manual English TABLE OF CONTENTS IMPORTANT SAFETY INSTRUCTIONS.......................... 1 GLOSSARY OF SYMBOLS....................................

More information

RT4F-110V/25A RECTIFIER

RT4F-110V/25A RECTIFIER The RT4F-110V/25A is a hot-pluggable switched mode rectifier (SMR) module designed to provide up to 25A of output current into a 110V nominal system. Examples of such systems are 60 cells lead acid (136V

More information

POWERVAR SECURITY PLUS SERIES DETAILED UPS SPECIFICATION (8kVA 10kVA)

POWERVAR SECURITY PLUS SERIES DETAILED UPS SPECIFICATION (8kVA 10kVA) POWERVAR SECURITY PLUS SERIES DETAILED UPS SPECIFICATION (8kVA 10kVA) A55-00017 SEC PLUS 8-10 KVA MAREKTING SPECS REV. A 9/10 8kVA, 10kVA POWERVAR Isolated On-Line UPS Specifications Index 1.0 General

More information

selectivity module Selective monitoring of 24 V DC load circuits

selectivity module Selective monitoring of 24 V DC load circuits Siemens AG 07 Miniature circuitbreaker versus electronic selectivity module Selective monitoring of 4 V DC load circuits In modern plant and machine construction all 4 V DC loads whether rugged electro-mechanical

More information

RT9-48V/1.4kW Rectifier Specification

RT9-48V/1.4kW Rectifier Specification The RT9-48V/1.4kW is a switched mode rectifier (SMR) module that delivers up to 1.4kW of output power (and up to 30A output current) into a 48V nominal DC system. The RT9 suits AC supply voltages between

More information

ABL1RPM24100 regulated SMPS - single phase V input - 24 V output W

ABL1RPM24100 regulated SMPS - single phase V input - 24 V output W Characteristics regulated SMPS - single phase - 100..240 V input - 24 V output - 240 W Complementary Input voltage limits Network frequency limits Inrush current Main Range of product Product or component

More information

Zener Barriers Bulletin 937Z

Zener Barriers Bulletin 937Z Technical Data Zener Barriers Bulletin 937Z Topic Page Introduction 2 Mounting 2 Housing 3 Operating Principle 3 Specifications 6 Introduction Allen-Bradley Zener barriers are a cost-effective solution

More information

Backplane. Allen-Bradley. System integration. Backplane

Backplane. Allen-Bradley. System integration. Backplane Backplane System integration Allen-Bradley Backplane Backplanes designed for minimum overall life cycle costs Simple, reliable and professional design Using standard cost-optimised DIN-rail devices Flexible

More information

SLC Expansion Units Catalog Nos EI01, -El02,-El03, -El04, - IUS,-El06, -E107

SLC Expansion Units Catalog Nos EI01, -El02,-El03, -El04, - IUS,-El06, -E107 PRODUCT DA TA I YY J SLC 700 110 Expansion Units Catalog Nos. 1745-EI01, -El02,-El03, -El04, - IUS,-El06, -E107 e nit SLC 100 expansion units can be used with either the SLC 100 processor unit or SLC 150

More information

ABL1REM24100 regulated SMPS - single phase V input - 24 V output W

ABL1REM24100 regulated SMPS - single phase V input - 24 V output W Characteristics regulated SMPS - single phase - 100..240 V input - 24 V output - 240 W Complementary Input voltage limits Network frequency limits Inrush current Main Range of product Product or component

More information

Chrome DIN Rail Power Supply 24V 10W 1 Phase (Class II & NEC Class 2) / DRC-24V10W1A

Chrome DIN Rail Power Supply 24V 10W 1 Phase (Class II & NEC Class 2) / DRC-24V10W1A Highlights & Features Protection Class II, Double Isolation (No Earth connection is required) Universal AC input voltage and full power up to 55 C Power will not de-rate for the entire input voltage range

More information

Quick Start Guide. SEB-710 I/O Expansion board. Introduction

Quick Start Guide. SEB-710 I/O Expansion board. Introduction SEB-710 I/O Expansion board Revision 1.0 - (March, 2011) Saflec Systems (Pty) Ltd Quick Start Guide Introduction The SEB-710 is an I/O expansion device for additional inputs and outputs. It has eight relay

More information

BNS SERIES - COMPATIBLE SERIES AES SAFETY CONTROLLERS SELECTION CHART AVAILABLE STANDARD MODELS

BNS SERIES - COMPATIBLE SERIES AES SAFETY CONTROLLERS SELECTION CHART AVAILABLE STANDARD MODELS BNS SERIES - COMPATIBLE SERIES AES SAFETY CONTROLLERS SELECTION CHART AVAILABLE STANDARD MODELS Safety Controller Suitable for use with Coded-Magnet Sensor Part Numbers below BNS250... BNS33... BNS303...

More information

ATS-16 HV USER MANUAL. Automatic Transfer Switch 16A / 230Vac V090318

ATS-16 HV USER MANUAL. Automatic Transfer Switch 16A / 230Vac V090318 ATS-16 HV Automatic Transfer Switch 16A / 230Vac USER MANUAL V090318 SAFETY Intended use The ATS-16 HV device serves as a power source selector to provide improved power supply for connected loads. ATS-16

More information

RT4F-48V/50A-WAC RECTIFIER

RT4F-48V/50A-WAC RECTIFIER The RT4F-48V/50A-WAC is a switched mode rectifier (SMR) module designed to provide up to 58A of output current into a 48V nominal system, over a wide range of AC input voltage. This rectifier has been

More information

SECTION VARIABLE FREQUENCY MOTOR CONTROLLERS (VFD)

SECTION VARIABLE FREQUENCY MOTOR CONTROLLERS (VFD) SECTION 26 29 23 VARIABLE FREQUENCY MOTOR CONTROLLERS (VFD) PART 1 -GENERAL 1.1 SYSTEM DESCRIPTION A. Definitions: The Variable Speed AC Motor Drive (hereafter referred to as "VFD") shall be designed to

More information

MAINTENANCE MANUAL. EDACS REDUNDANT POWER SUPPLY SYSTEM 350A1441P1 and P2 POWER MODULE CHASSIS 350A1441P3, P4, AND P5 POWER MODULES TABLE OF CONTENTS

MAINTENANCE MANUAL. EDACS REDUNDANT POWER SUPPLY SYSTEM 350A1441P1 and P2 POWER MODULE CHASSIS 350A1441P3, P4, AND P5 POWER MODULES TABLE OF CONTENTS MAINTENANCE MANUAL EDACS REDUNDANT POWER SUPPLY SYSTEM 350A1441P1 and P2 POWER MODULE CHASSIS 350A1441P3, P4, AND P5 POWER MODULES TABLE OF CONTENTS SPECIFICATIONS*... 2 INTRODUCTION... 3 DESCRIPTION...

More information

S Reclosers Form 4C Microprocessor-Based Recloser Control KME (120V) and KME (240V) Analog Current Metering Accessory Design II

S Reclosers Form 4C Microprocessor-Based Recloser Control KME (120V) and KME (240V) Analog Current Metering Accessory Design II Reclosers Form 4C Microprocessor-Based Recloser Control KME4-88-1 (120V) and KME4-88-2 (240V) Analog Current Metering Accessory Design II Service Information S280-77-6 961015, 961016 Figure 1. Kyle KME4-88

More information

GuardLogix: Safety Gate Application with SensaGuard Switch

GuardLogix: Safety Gate Application with SensaGuard Switch Safety Application Example GuardLogix: Safety Gate Application with SensaGuard Switch Safety Rating: PLe, Cat. 4 to EN ISO 13849.1 2008 Introduction...2 Important User Information...2 General Safety Information...3

More information

Industrial Power Supplies

Industrial Power Supplies 75-600 Watt Features Switch mode power supplies for DIN-rail mounting 4 power ranges with 3, 6, 12 and 24 A output current (24 VDC models) Selectable 115/ 230 VAC input Very low ripple and noise EMI complies

More information

Two-hand relay modules SRB 201ZH 44 Schmersal Industrial switching systems

Two-hand relay modules SRB 201ZH 44 Schmersal Industrial switching systems SR 2ZH A 23 3 3 X S2 S A. K K2 PROTECT SR 2ZH Dimensions Two-hand module to DIN EN 574 (997) type III C Plug-in terminals 2 safety enabling outputs feedback output with NC function (floating contact) Electronic

More information

INSTALLATION, OPERATION & MAINTENANCE CRFF Series Wall Control Console. ECM Motors. ACC1-25 (Part # ) Revision:

INSTALLATION, OPERATION & MAINTENANCE CRFF Series Wall Control Console. ECM Motors. ACC1-25 (Part # ) Revision: INSTALLATION, OPERATION & MAINTENANCE CRFF Series Wall Control Console ACC1-25 (Part # 63971-002) ECM Motors Revision: 10.01.13 Page: 2 of 11 Table of Contents Safety Precautions...3 Overview...3 Specifications...4

More information

Applying branch circuit breakers and supplementary protectors in North America

Applying branch circuit breakers and supplementary protectors in North America Supersedes June 2017 FAZ-NA-L FAZ-NA FAZ Applying branch circuit breakers and supplementary protectors in North America Introduction Eaton offers three types of miniature circuit breakers for use in North

More information

Chrome DIN Rail Power Supply 5V 7.5W 1 Phase (Class II & NEC Class 2) / DRC-5V10W1AZ

Chrome DIN Rail Power Supply 5V 7.5W 1 Phase (Class II & NEC Class 2) / DRC-5V10W1AZ Highlights & Features Protection Class II, Double Isolation (No Earth connection is required) Universal AC input voltage and full power up to 55 C Power will not de-rate for the entire input voltage range

More information

ABL8REM24050 regulated SMPS - 1 or 2-phase V AC - 24 V - 5 A

ABL8REM24050 regulated SMPS - 1 or 2-phase V AC - 24 V - 5 A Characteristics regulated SMPS - 1 or 2-phase - 100..240 V AC - 24 V - 5 A Complementary Input voltage limits Network frequency Inrush current Main Range of product Product or component type Power supply

More information

USER MANUAL INSTALLATION MANUAL. Isolation transformers. ITR Isolation Transformer 7000 W 230V/32A

USER MANUAL INSTALLATION MANUAL. Isolation transformers. ITR Isolation Transformer 7000 W 230V/32A USER MANUAL INSTALLATION MANUAL Isolation transformers ITR000702000 Isolation Transformer 7000 W 230V/32A Victron Energy B.V. The Netherlands General phone: +31 (0)36 535 97 00 Customer support desk: +31

More information

Chrome DIN Rail Power Supply 12V 9.96W 1 Phase (Class II & NEC Class 2) / DRC-12V10W1A

Chrome DIN Rail Power Supply 12V 9.96W 1 Phase (Class II & NEC Class 2) / DRC-12V10W1A Highlights & Features Protection Class II, Double Isolation (No Earth connection is required) Universal AC input voltage and full power up to 55 C Power will not de-rate for the entire input voltage range

More information

PACSystems* RX3i IC695PSA040

PACSystems* RX3i IC695PSA040 August 2012 PACSystems* RX3i IC695PSA040 Power Supply, 120/240VAC or 125VDC, 40 Watts The PACSystems * RX3i power supply IC695PSA040 is a 40-Watt supply that operates from an input voltage source in the

More information

IC693PWR331 High Capacity Power Supply, 24 VDC Input

IC693PWR331 High Capacity Power Supply, 24 VDC Input IC693PWR331 High Capacity Power Supply, 24 VDC Input The Series 90-30 DC input High Capacity power supply (IC693PWR33) is a 30 watt wide range supply designed for 24 VDC nominal inputs. For applications

More information

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL:

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: 99 Washington Street Melrose, MA 02176 Fax 781-665-0780 TestEquipmentDepot.com IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: 61-609 The Service Information provides the following information: Precautions

More information

NOTE: All facility requirements must be met before 3D Systems Customer Support can schedule a trip to your facility to install the printer.

NOTE: All facility requirements must be met before 3D Systems Customer Support can schedule a trip to your facility to install the printer. Facility Guidelines This section provides details relating to site selection, site preparation and readiness of the facility to accept and install the ProJet Professional Printing System. Discuss appropriate

More information

ADAPTER SERIES SST-AD60-C

ADAPTER SERIES SST-AD60-C ADAPTER SERIES SST-AD60-C Compact, intelligent multi-voltage 60W USB Type-C adapter Maximum 60W 3A fast charging for USB Type-C equipped laptops, tablets, and mobile phones Intelligent detection and auto

More information

ControlLogix Communication Modules

ControlLogix Communication Modules ControlLogix Communication Modules Separate communication modules are available for different networks. Install multiple communication modules into the ControlLogix backplane to bridge or route control

More information

Railway & Industrial Power Solutions

Railway & Industrial Power Solutions Railway & Industrial Power Solutions belfuse.com/power-solutions DC-DC Converters for General Purpose Rail Applications RCM Series The RCM Series (Railway Chassis Mount) DC-DC converters are reliable power

More information

PACSystems RX3i IC695PSA140

PACSystems RX3i IC695PSA140 GFK2399A October 2005 PACSystems RX3i IC695PSA140 120/240VAC or 125VC, 40 Watts IC695PSA140 is a multipurpose 40Watt supply that operates from an input voltage source in the range of 85 to 264 VAC or 100

More information

GuardLogix: Dual Zone Gate Protection with E-stop and Trojan Interlock Switch

GuardLogix: Dual Zone Gate Protection with E-stop and Trojan Interlock Switch Safety Application Example GuardLogix: Dual Zone Gate Protection with E-stop and Trojan Interlock Switch Safety Rating: PLd, Cat. 3 to EN ISO 13849.1 2008 Introduction... 2 Important User Information...

More information

Installation Instructions

Installation Instructions Installation Instructions Cat. No. 1771-OND Series B This document provides information on: important pre-installation considerations power supply requirements installing the module setting the fault mode

More information

QUINT-BUFFER/24DC/24DC/40

QUINT-BUFFER/24DC/24DC/40 Buffer module Data sheet 105496_en_01 PHOENIX CONTACT 2013-11-01 1 Description The QUINT BUFFER buffer module combines the electronic switchover unit and power storage in the same housing. The buffer module

More information

RТTH DUAL ROOM SWITCH

RТTH DUAL ROOM SWITCH DUAL ROOM SWITCH FOR TEMPERATURE AND RELATIVE HUMIDITY Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS PRODUCT DESCRIPTION ARTICLE CODES INTENDED AREA OF USE TECHNICAL DATA

More information

4170 POS System Installation Guide

4170 POS System Installation Guide 4170 POS System 4170 Installation Guide Thank you for selecting UTC RETAIL s innovative Model 4170 Point of Sale solution! This Installation Guide will help you efficiently install the 4170 POS. The document

More information

Obtaining Documentation and Submitting a Service Request, page xvii Safety Warnings, page xvii Safety Guidelines, page xx

Obtaining Documentation and Submitting a Service Request, page xvii Safety Warnings, page xvii Safety Guidelines, page xx Preface Obtaining Documentation and Submitting a Service Request, page xvii Safety s, page xvii Safety Guidelines, page xx Obtaining Documentation and Submitting a Service Request For information on obtaining

More information

E-Series Site Preparation Guide

E-Series Site Preparation Guide E-Series Site Preparation Guide September 2017 215-11797_A0 doccomments@netapp.com Table of Contents 3 Contents Deciding whether to use this guide... 10 Specifications of the model 3040 40U cabinet...

More information

AVR Series 120V 700VA 350W Ultra-Compact Line-Interactive UPS with USB port

AVR Series 120V 700VA 350W Ultra-Compact Line-Interactive UPS with USB port AVR Series 120V 700VA 350W Ultra-Compact Line-Interactive UPS with USB port MODEL NUMBER: AVR700U Highlights 700VA ultra-compact 120V line interactive UPS Corrects brownouts and overvoltages from 83V to

More information

Industrial Power Supplies

Industrial Power Supplies 50-600 Watt Features Switch mode power supplies for DIN-rail mounting 6 power ranges with 2, 3, 6, 12, 20 and 24 A output current (24 VDC models) Selectable 115/ 230 VAC input Very low ripple and noise

More information

Chrome DIN Rail Power Supply 24V 10W 1 Phase (Class II & NEC Class 2) / DRC-24V10W1AZ

Chrome DIN Rail Power Supply 24V 10W 1 Phase (Class II & NEC Class 2) / DRC-24V10W1AZ Highlights & Features Protection Class II, Double Isolation (No Earth connection is required) Universal AC input voltage without power de-rating Efficiency > 80.0% @ 115Vac & 230Vac NEC Class 2 / Limited

More information

CompactBlock Guard I/O Modules ArmorBlock Guard I/O Modules POINT Guard I/O Modules

CompactBlock Guard I/O Modules ArmorBlock Guard I/O Modules POINT Guard I/O Modules Overview Overview Control and monitor your safety devices with Guard I/O. When used with Rockwell Automation safety controllers, Guard I/O communicates on EtherNet/IP or DeviceNet using CIP Safety protocol.

More information

10 kva 3/1 15 kva 3/1 20 kva 3/1 10 kva 3/3 15 kva 3/3 20 kva 3/3 30 kva 3/3 40 kva 3/3 UOUS SERV WARRANTY

10 kva 3/1 15 kva 3/1 20 kva 3/1 10 kva 3/3 15 kva 3/3 20 kva 3/3 30 kva 3/3 40 kva 3/3 UOUS SERV WARRANTY OF CONTINUOUS SERVICE YEARS WARRANTY B8000 FXS 10-40kVA BORRI B8000 FXS With disturbances to the electrical supply being one of the major causes of IT downtime, the UPS system is regarded as the most critical

More information

Battery charger. Power plants. Substations. Rail and infrastructure. Industry. Thyristor controlled with controller GMU

Battery charger. Power plants. Substations. Rail and infrastructure. Industry. Thyristor controlled with controller GMU Battery charger Thyristor controlled with controller GMU Power plants Substations Rail and infrastructure Industry Battery charger Thyristor controlled with controller GMU Battery back-up DC-power supply

More information

PowerFlex 750-Series AC Drives

PowerFlex 750-Series AC Drives PowerFlex 750-Series AC Drives Cost-effective Solution Designed for Ease of Use, Integration & Application Flexibility The Allen-Bradley PowerFlex 750-Series of AC Drives is aimed at maximizing your investment

More information

Energy Storage Systems Utilizing the SunDial Plus 30PV+S Inverter

Energy Storage Systems Utilizing the SunDial Plus 30PV+S Inverter APPLICATION NOTE 601 Energy Storage Systems Utilizing the SunDial Plus 30PV+S Inverter CONTENTS 1.0 Purpose and Scope.... 1 2.0 Disclaimer.... 1 3.0 Overall Energy Storage System... 1 4.0 Electrical Interfaces...

More information

Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protectors Specifications Bulletin Number 1492, 1692

Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protectors Specifications Bulletin Number 1492, 1692 Technical Data Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protectors Specifications Bulletin Number 1492, 1692 Topic Page 1489-M Miniature Circuit Breakers 1 1492-SP Supplementary Protectors

More information

Masibus Automation And Instrumentation Pvt. Ltd.

Masibus Automation And Instrumentation Pvt. Ltd. User Manual 16 CHANNEL DIGITAL INPUT MODULE MASDI DI16 16D Masibus Automation And Instrumentation Pvt. Ltd. B/30, GIDC Electronics Estate, Sector25, Gandhinagar382044, Gujarat, India Phone No : 91 79 23287275

More information

AVR Series 230V 550VA 300W Ultra-Compact Line-Interactive UPS with USB port, C13 Outlets

AVR Series 230V 550VA 300W Ultra-Compact Line-Interactive UPS with USB port, C13 Outlets AVR Series 230V 550VA 300W Ultra-Compact Line-Interactive UPS with USB port, C13 Outlets MODEL NUMBER: AVRX550U Highlights 550VA ultra-compact 230V line interactive UPS Corrects brownouts and overvoltages

More information

Installation, Testing, and Operating Procedures 30 AMP PORTABLE AND PERMANENT SERIES GFCI SINGLE and MULTIPHASE

Installation, Testing, and Operating Procedures 30 AMP PORTABLE AND PERMANENT SERIES GFCI SINGLE and MULTIPHASE IMPORTANT! Please read all the information on this sheet. SAVE THESE INSTRUCTIONS! NOTICE BEFORE USING READ INSTRUCTIONS COMPLETELY. TO BE INSTALLED BY A QUALIFIED ELECTRICIAN IN ACCORDANCE WITH NATIONAL

More information

LEVELUPS T3. SERIES kva ONLINE UPS 3:3 PHASE VFI TYPE. Highest Reliability and Robust Protection for Industrial Loads

LEVELUPS T3. SERIES kva ONLINE UPS 3:3 PHASE VFI TYPE. Highest Reliability and Robust Protection for Industrial Loads LEVELUPS T SERIES DATA CENTER MEDICAL TRANSPORT INDUSTRY EMERGENCY VFI TYPE PF= 0.9 Service UPS ONLINE TOWER POWER FACTOR SERVICE HIGHLIGHTS Built In Inverter Transformer for DC-AC Galvanic Protection

More information

SE Engineering, PC strives to be a leader in the power system engineering field by providing our customers with the highest level of quality,

SE Engineering, PC strives to be a leader in the power system engineering field by providing our customers with the highest level of quality, SE Engineering, PC strives to be a leader in the power system engineering field by providing our customers with the highest level of quality, integrity, and innovation. Our mission is to offer the safest,

More information

AVR Series 120V 700VA 350W Ultra-Compact Line-Interactive UPS with USB port

AVR Series 120V 700VA 350W Ultra-Compact Line-Interactive UPS with USB port AVR Series 120V 700VA 350W Ultra-Compact Line-Interactive UPS with USB port MODEL NUMBER: AVR700U Highlights 700VA ultra-compact 120V line interactive UPS Corrects brownouts and overvoltages from 83V to

More information

Chrome DIN Rail Power Supply 24V 30W 1 Phase (Class II & NEC Class 2) / DRC-24V30W1AZ

Chrome DIN Rail Power Supply 24V 30W 1 Phase (Class II & NEC Class 2) / DRC-24V30W1AZ Highlights & Features Protection Class II, Double Isolation (No Earth connection is required) Universal AC input voltage and full power up to 55 C Power will not de-rate for the entire input voltage range

More information

Safety Standards. Model Number:

Safety Standards. Model Number: PMC Highlights & Features Universal AC input range from 85Vac to 264Vac without power de-rating High operating ambient temperature, > 60 o C de-rating power High MTBF > 700,000 hrs. as per Telcordia SR-332

More information

SIPLUS S7-200 PS 203. Overview

SIPLUS S7-200 PS 203. Overview SIPLUS S7-200 PS 203 Overview Design and functionality of the power supply are optimally adapted to the SIPLUS S7-200 micro PLC Slim design Particularly suitable for low cabinet depths Note: SIPLUS extreme

More information

HP R/T2200 UPS. Overview. Precautions. Installation Instructions. The HP UPS R/T2200 features power protection for loads up to 2200 VA/1600 W.

HP R/T2200 UPS. Overview. Precautions. Installation Instructions. The HP UPS R/T2200 features power protection for loads up to 2200 VA/1600 W. HP R/T2200 UPS Installation Instructions Overview The HP UPS R/T2200 features power protection for loads up to 2200 VA/1600 W. For more information about any of the topics covered in this document, see

More information

ICS Regent. Relay Output Modules. Low Power and High Power (T3446L and T3446H) PD-6017

ICS Regent. Relay Output Modules. Low Power and High Power (T3446L and T3446H) PD-6017 ICS Regent PD-6017 Relay Output Modules Low Power and High Power (T3446L and T3446H) Issue 1, March, 06 Relay output modules provide control of eight user output loads. Two types of relay output modules

More information

R E C T I F I E R I N V E R T E R C O N V E R T E R MP7

R E C T I F I E R I N V E R T E R C O N V E R T E R MP7 Uninterruptible Power Supply Product Specifications Description The industrial UPS provides your critical equipment with uninterruptible 3 phase AC power. Using high frequency dual conversion technology,

More information