Excel Power Distribution

Save this PDF as:
 WORD  PNG  TXT  JPG

Size: px
Start display at page:

Download "Excel Power Distribution"

Transcription

1 Excel Power Distribution Section 7 In this Section: Pages Power Distribution Units 154 Efficiency Measurements 154 Excel Modular PDU Range 155 Excel Standard PDUs 156 Excel Intelligent PDU Family 158 Excel Desktop Power Distribution Units

2 Excel Power Distribution Power Distribution Units Power Distribution Units (PDUs) are an important and often overlooked part of an infrastructure design and installation. At their simplest they deliver the power required for the equipment within the rack, more advanced units can provide management information on power consumption and local environmental conditions such as temperature and humidity. It is important to consider the PDU requirement at the rack installation stage rather than as an afterthought at the equipment installation stage. Making sufficient provision for the power will ensure the longevity and best use of the rack. PDUs can be fitted in various different ways within the rack: front; rear; horizontal rack mount; vertical side mount. This may be dependent on Available space in the rack Position of equipment Position of the power input for specific equipment What capacity and how many PDU s should there be? For a rack that will be dedicated for equipment consideration should be made for dual power supply. In this case at least two PDUs will be required to provide the primary and secondary power supplies. This is typical for data centre and high importance communication rooms. Where racks are used to serve smaller locations and house a mixture of equipment and cabling then the requirement may be less. However, as networks and installations evolve over time the requirements change. There are a variety of types of sockets including IEC C13 & C19 type used throughout the world. Additionally there are country specific types, such as the UK (BS1363), Schuko and NFC French styles. Excel has Standard, Modular, Monitored and Managed PDUs to suit all requirements. Efficiency Measurements The more energy that is used in a data centre (or other facility) results in higher bills. These account for major ongoing costs in operation. Efficiency measurements are required to establish the performance of the data centre. Depending on the organisation or current trends these can be carried out in many different ways. The following two make the same comparison, just expressed in different ways. Power Usage Effectiveness Power Usage Effectiveness (PUE) compares the energy used directly for the computer equipment with the total power used in the facility. The calculation is a simple formula: Total Facility Energy PUE = IT Equipment Energy Total Facility Energy is a measure of all energy used including that consumed by the IT equipment. This includes, measuring the energy consumed as electricity, gas etc. IT Equipment Energy only relates to the energy used for the direction operation of the equipment. All energy measurements must be in the same units (or converted), for example kwh (kilowatt hours). The resulting number does not have units. The aim is to reduce the PUE, with a PUE of 1 meaning only the IT Equipment uses energy. The typical PUE is difficult to quantify. However, the aim should always to be below 2. Data Centre Infrastructure Efficiency Data Centre Infrastructure Efficiency (DCIE) is the inverse of PUE and is expressed as a percentage. Therefore the formula is: IT Equipment Energy DCIE = Total Facility Energy Using and recording the information that is supplied from the Excel Intelligent PDUs can help calculate the IT Equipment Energy usage, which in turn allows the PUE or DCIE to be calculated. Once the baseline figure is calculated steps can be put in place and the improvements may be measured. 154

3 Excel Modular PDU Range The Excel range of modular PDU s introduce flexibility and design options to suit your power requirements. A range of socket modules are available which snap into the housing quickly, easily and securely without the need for tooling. First choose the empty housing hardware: Part Number No. of Modules Housed Input Connectivity Output Connectivity Voltage Current Rating (Amps) Optional 250V 32A Optional 250V 16A Optional 250V 13A Optional 250V 32A Optional 250V 16A Optional 250V 13A Then pick your choice of power modules to go into your chosen housing. You can mix and match socket styles to suit your requirements and be safe in the knowledge that you can change them at a future date with the snap in connectivity. The Excel power modules may be added or removed safely without turning the power off. Installations of modular housing with empty positions is safe and makes provision for future power requirements without having to commit to the socket connectivity. See below for the list of modules available. Part Number No. of Sockets Feature Output Connectivity Voltage Total Current Rating (Amps) Fused 250V 16A Fused 250V 10A Fused 250V 16A Fused 250V 10A Fused 250V 16A Fused 250V 16A CONNECTIVITY KEY 3 pin - BS1363 Commando Style IEC C13 - IEC60320 C19 - IEC60320 Universal - GST18 Schuko French IEC

4 Excel Power Distribution Excel Standard PDUs The Excel Standard PDUs are available in a variety of sizes and socket types. The horizontal PDUs have the mounting brackets at the front to allow attachment to the 19 profiles. The vertical PDUs have the mounting brackets at the rear to allow mounting to single 19 profile, side supports or flat surface. Note that vertical PDU s are sometimes referred to as Zero U, due to mounting outside of the vertical equipment mounting rails. A range of input connectivity plugs are available to support different installation environments. The IEC Commando style plugs are utilised in Data Centres and other locations where the total current load for the PDU will exceed the standard domestic plug rating (UK BS1363, Schuko, French NFC. etc). It is becoming more common in rack installations to use either the C13 or C19 IEC output sockets. Within the range there are also PDUs with C14 and C20 Input Plugs so that a PDU may be connected direct to a rack mounted UPS (Uninterruptible power supply). Part Number No. of Sockets Switched Filtered Mounting Orientation Input Connectivity Output Connectivity Voltage Current Rating (Amps) D13-4H-EXL 4 ü Horizontal 250V 13A D13-5H-EXL 5 ü Horizontal 250V 13A D13-6-EXL 6 ü Vertical 250V 13A D13-6H-EXL 6 ü Horizontal 250V 13A D13-8-EXL 8 ü Vertical 250V 13A D13-10-EXL 10 ü Vertical 250V 13A D13-12-EXL 12 ü Vertical 250V 13A D13-6HF-EXL 6 ü ü D13-8F-EXL 8 ü ü D13-10F-EXL 10 ü ü D13-12F-EXL 12 ü ü Horizontal 250V 13A Vertical 250V 13A Vertical 250V 13A Vertical 250V 13A D16-6H-EXL 6 ü Horizontal 250V 16A D16-8-EXL 8 ü Vertical 250V 16A D16-10-EXL 10 ü Vertical 250V 16A D16-12-EXL 12 ü Vertical 250V 16A D32-8-EXL 8 ü Vertical 250V 32A D32-10-EXL 10 ü Vertical 250V 32A D32-12-EXL 12 ü Vertical 250V 32A ü Vertical 12 & 4 250V 32A ü Vertical 16 & 4 250V 32A ü Vertical 20 & 4 250V 32A D13-6HIEC-EXL 6 Horizontal 250V 13A 156

5 Part Number No. of Sockets Switched Filtered Mounting Orientation D13-6HIECF-EXL 6 ü Input Connectivity Output Connectivity Voltage Horizontal 250V 13A Current Rating (Amps) D13-8IECF-EXL 8 ü Vertical 250V 13A D13-10IEC-EXL 10 Vertical 250V 13A D13-12IEC-EXL 12 Horizontal 250V 13A ü Horizontal 250V 10A ü Vertical 250V 10A ü Vertical 250V 10A ü Vertical 250V 10A ü Horizontal 250V 16A ü Vertical 250V 16A ü Vertical 250V 16A ü Vertical 250V 16A ü Horizontal 250V 10A ü Vertical 250V 10A ü Vertical 250V 10A ü Vertical 250V 10A Horizontal 250V 16A Horizontal 250V 16A ü Horizontal 250V 16A ü Horizontal 250V 16A Horizontal 250V 16A Horizontal 250V 16A For the full range of PDU s available please visit 157

6 Excel Power Distribution Excel Intelligent PDU Family The Excel Intelligent PDU Family offers a high specification portfolio of power distribution units that are designed to suit any environment, where monitoring or managing of information is required. Excel is able to offer a PDU with up to 48 sockets with any combination of socket type including UK, Schuko, C13, C19 etc. We design and build everything in the UK, and have developed a wide range of products that cover the whole scale from overall monitored products to individual socket monitoring and individual socket switching. With a turnaround of approx days from order to manufacture and delivery, the Excel Intelligent PDU range provides total flexibility to allow you to build a solution that fits your individual requirement. From our experience there isn t an Intelligent PDU of one size fits all so we provide you with a simple build configuration to get exactly what you need. Our range of products has been developed so they can work as individual masters or run as a master and slave system. We can have one master with up to 31 slaves, all from one IP address, reducing the requirement for multiple IP addresses. The Excel Intelligent PDU range also comes with free software making it a highly competitive solution allowing the user to monitor and report on up to 50 IP addresses with the software. In theory it is possible to have up to 1600 PDU s each with up to 48 outlets per PDU, all from one free software licence. The Excel Intelligent PDU range provides billing quality accuracy to better than 1%, allowing the unit to be used in co-location centres for the monitoring and charging of power used. Our system is designed for use in both single and 3 phase systems and to that end is designed with one monitoring board, but with a meter board at the beginning where the input power flows through, allowing them to sample the power 4000 times per second. This enables the units to measure the power at every point on the sine wave providing a very accurate result. Most Intelligent PDUs available only sample between 200 and 250 volts, so results are not as accurate, particularly with RMS voltages. The meter board allows the unit to economically meter a 3 phase system, as it uses 3 meter boards, one per phase. If required the PDU can be split into 3 separate sections (for use in co-location facilities) and group the results for 3 separate users on the same power strip. Other possibilities are to measure both A and B feeds through one monitoring system. 158

7 Excel Intelligent PDU Family The Excel Intelligent PDU Product Range The Excel Intelligent PDU range is a highly flexible solution. All versions have a built-in Environmental centre which covers a series of functions. As standard the units have a local display this can be supplemented by an additional remote display that can be mounted on the front of a rack for easy reading. Excel INT1 Includes the necessary network and environmental ports plus a local RGB display. The information provided is as follows: Local display via the RGB shows per phase: Kilowatts Voltage Overall amps (current) Cumulative Kw/hours True Power Factor Overall PMS Unit shows per phase remotely: Kilowatts Frequency kwa Voltage Overall amps (current) Cumulative Kw/hours BTU,s K/Joules Kg CO2 True Power Factor The unit can also provide the following optional environmental and security capabilities: 8 x temperature sensors (daisy chained through a single port) 1 x temperature and humidity sensor port 1 x door lock port 1 x key pad port 1 x door sensor port 1 x close contact port to allow connection of 3 devices Remote display port Excel INT2 As above plus monitoring at socket level. Amps kwh VA Watts Excel INT3 Includes both individual socket monitoring and individual socket switching As INT2 with the following additional features: Per socket shows remotely: o Amps (current) o Cumulative Kw/hours Per socket switching Measurement Accuracy The Meter board measures the complete AC waveform 4000 times a second to provide a class II billing quality measurement of RMS Volts, RMS Amps, Kilowatts, Power Factor, Frequency, and Internal PDU Temperature. Additional measurements of Peak Volts, Peak Amps, and kva are also available. These values are used to calculate kwh, BTU s, Kilograms of Co2, Kilojoules, and Energy Cost. 159

8 Excel Power Distribution Excel Intelligent PDU Family Building your Excel Intelligent PDU Please follow these basic steps to build your Excel Intelligent PDU Management Level Choose from: INT1 - Local and remote overall powering INT2 - Local and remote overall and per socket monitoring INT3 - Local and remote overall and per socket monitoring and switching Phase & Orientation 1V = Single Phase Vertical 3V = 3 Phase Vertical 1H = Single Phase Horizontal 3H = 3 Phase Horizontal Input & Power C14 = 10A C20 = 16A UK = 13A SCH = 16A Com16 = 16A Commando Com32 = 32A Commando X = Open Ended (i.e. no connector fitted, suitable for hard wiring) Outlets - Quantity & Type UKL = UK 13A Left UKR = UK 13A Right SCH = Schuko C13 = 10A C19 = 16A Total number of sockets per PDU needs to be in multiples of 4 (these can be mixed i.e. 10 x C13 and 2 x C19 units) Additional Outlet Options 2nd, 3rd or 4th outlet selection Lead Length Add the length of lead required Add T if required at the top of the unit and B if at the bottom NB. The standard length is 3 metres 160

9 Excel Intelligent PDU Family Communications Protocol s The Excel Intelligent PDU has embedded HTML web pages, which can be viewed as either HTTP or the more secure HTTPs. The web pages allow a user to Monitor and control the power usage of a PDU, as well as providing the interface to set up the PDU and commission it for use. The PDU can also communicate via SNMP V1, 2, and 3, enabling the user to integrate the PDU s with their own software choice using a MIB file. RGB Display As standard the PDU comes with a built in RGB Display, the display shows IP Address, kwh, and Volts, Amps, power factor and kilowatts per phase. In the event of an alarm condition the display changes colour and flashes giving a visual representation of a problem. An optional remote display can be fitted to the rack door or in a prominent position where the inbuilt display may be obscured at the rear of a rack. Socket Types C13 - IEC Pin - BS1363 BS1363 & C13 - IEC60320 C19 - IEC60320 Schuko 161

10 Excel Power Distribution IntelligentPDU PDUs Available Local & remote overall power monitoring Local & remote overall and per socket monitoring Local & remote overall and per socket monitoring, and power switching Socket Types Any socket combination: C13, C19 and Schuko Locking Single or three phase Amp Up to 48 sockets on one PDU Features UK design and manufacturer Short leads times Daisy chain up to 32 units together - 1 IP address Environmental ports - 8 temperature sensors and humidity sensor 3 volt free contacts Door control for up to 2 doors Remote LCD display Accuracy 1IP Control Web browser SNMP Mod-Bus Software (Free) Optional card reader port www 162

11 Excel Desktop Power Distribution Units Excel Desktop Power Distribution Units offer a convenient addition to the work place. Available with either UK or Schuko power sockets and options for 6c apertures to accept data outlets and USB power in a stylish anodised aluminium finish, the PDUs are easily fitted to the desktop with the supplied clamps. The Excel Desktop PDUs eliminate the need to scramble under the desk to connect up laptop and other power supplies. With the option of the 6c Apertures and the USB power points it increases the flexibility of any work area for the resident or casual occupant. The USB outlets supply up to 2.1 amps permitting phones and tablets to be charged. An illuminated master power switch is fitted to each PDU. The power leads are supplied separately to ensure that the correct length is selected. Features Desktop mounting USB Power Option Optional 6c Apertures UK or Schuko Power Sockets Removable Power Cord Illuminated Master Power Switch Part Number UK Sockets Schuko Sockets USB Power 6c Apertures Length Height Depth mm 78 mm 91 mm mm 78 mm 91 mm mm 78 mm 91 mm mm 78 mm 91 mm mm 78 mm 91 mm mm 78 mm 91 mm mm 78 mm 91 mm mm 78 mm 91 mm mm 78 mm 91 mm mm 78 mm 91 mm mm 78 mm 91 mm mm 78 mm 91 mm mm 78 mm 91 mm mm 78 mm 91 mm 163

12 Excel Power Distribution 164

PDU. InfraPower POWER AUSTI AUSTIN AUSTIN AUSTIN 3 PHASE WSI WI WS W MD BASIC. Enclosure Power Management Solutions

PDU. InfraPower POWER AUSTI AUSTIN AUSTIN AUSTIN 3 PHASE WSI WI WS W MD BASIC. Enclosure Power Management Solutions PDU A AUSTI POWER 3 PHASE WSI WI WS W MD BASIC Temperature & Humidity Sensors A pair of sensors can be connected to one single W series PDU meter. 3 PHASE Free Management Software Manager enhances the

More information

New Product Release. Integrated Intelligent Power Distribution.

New Product Release. Integrated Intelligent Power Distribution. Integrated Intelligent Power Distribution. i-pdu has been developed to seamlessly integrate with Cooper B-Line s i-box and i-pal systems (access control and environmental monitoring system) providing the

More information

Power Monitoring in the Data Centre

Power Monitoring in the Data Centre Power Monitoring in the Data Centre Fixed or Wireless Steve Strange RCDD ANIXTER INTERNATIONAL Agenda Energy Consumption Case Study Reasons to Monitor Power Monitoring Environmental Monitoring Asset Tags

More information

Power Distribution Unit

Power Distribution Unit 414 Simple assembly Compact design Toolless clip attachment in the TS-IT Flexible mounting at the required height in the zero-u space lso suitable for individual installation on the enclosure frame Reliable

More information

YourPDU. by Schleifenbauer. This PDF has been optimised for viewing with Acrobat Reader. Click here to download it for free.

YourPDU. by Schleifenbauer. This PDF has been optimised for viewing with Acrobat Reader. Click here to download it for free. This PDF has been optimised for viewing with Acrobat Reader. Click here to download it for free. Your PDU 3..7 1. 2. Our advanced technology offers you accurate measurements and detailed data, so that

More information

PDU Inspired by Your Data Center. W IEC PDU Series

PDU Inspired by Your Data Center. W IEC PDU Series PDU Inspired by Your Data Center W IEC PDU Series Intelligent kwh PDU - W series Power Efficiency Management With today s increasing demand for high technology power management solutions, PDU kwh measurement

More information

Power Distribution. For technical support call Online catalog available at leviton.com 461

Power Distribution. For technical support call Online catalog available at leviton.com 461 INDEX FLX Series... 463 Switched Series... 464 Metered Series... 465 P1000 Series... 466 5500 & 5505 Series... 467 4500 Series... 468 For technical support call 800-824-3005 Online catalog available at

More information

SmartZone Rack Energy Kits Energy and Environmental Monitoring for Small Data Centers

SmartZone Rack Energy Kits Energy and Environmental Monitoring for Small Data Centers SmartZone Rack Energy Kits Energy and Environmental Monitoring for Small Data Centers SmartZone Rack Energy Kits Energy and Environmental Monitoring for Small Data Centers SmartZone Rack Energy Kits Features:

More information

Product Catalogue 2015 Power Distribution Monitoring & Remote I/O Radio Time Systems Isolators

Product Catalogue 2015 Power Distribution Monitoring & Remote I/O Radio Time Systems Isolators Product Catalogue 2015 Power Distribution Monitoring & Remote I/O Radio Time Systems Isolators Good. Great. GUDE. v2.5.5 Product Catalogue of Gude Analog- und Digitalsysteme Dear customer, Koeln, January

More information

ECO PDU Power Distribution Unit

ECO PDU Power Distribution Unit ECO PDU Distribution Unit PE6108/PE6208/PE8108/PE8208 ATEN has developed a new generation of green energy power distribution units (PDUs) to effectively increase the efficiency of data center power usage.

More information

KVM SYSTEMS KVM SYSTEMS

KVM SYSTEMS KVM SYSTEMS KVM SYSTEMS 7 LCD KVM Drawer Page 6-3 Analog KVM Switch with DB15 Ports Page 6-5 IP KVM Switch with DB15 Ports Page 6-7 IP KVM Switch with Cat 5/6 Ports Page 6-9 KVM Switch Accessories Page 6-12 KVM SYSTEMS

More information

SmartPro LCD 120V 1200VA 700W Line- Interactive UPS, AVR, 2U Rack/Tower, LCD, USB, DB9 Serial, 8 Outlets

SmartPro LCD 120V 1200VA 700W Line- Interactive UPS, AVR, 2U Rack/Tower, LCD, USB, DB9 Serial, 8 Outlets SmartPro LCD 120V 1200VA 700W Line- Interactive UPS, AVR, 2U Rack/Tower, LCD, USB, DB9 Serial, 8 Outlets MODEL NUMBER: SMART1200LCD Highlights Supports a half-load (350W) up to 14.3 min. during power outage

More information

Liebert MPH TM Managed Rack-PDU Systems monitoring and control

Liebert MPH TM Managed Rack-PDU Systems monitoring and control Liebert MPH TM Managed Rack-PDU Systems monitoring and control The Liebert MPH TM Managed Rack PDU is a power supply system with monitoring and control functions. The housing consists of a robust sheet

More information

Smart Monitoring System compact, secure, efficient

Smart Monitoring System compact, secure, efficient Smart Monitoring System compact, secure, efficient Transparency for more efficiency Continuously record and monitor the energy consumption of plant and machinery Visualise data on a display or through

More information

Knürr PowerTrans. Power Distribution Rack. Central connection unit for power supplies for individual server racks to

Knürr PowerTrans. Power Distribution Rack. Central connection unit for power supplies for individual server racks to Knürr PowerTrans Power Distribution Rack Central connection unit for power supplies for individual server racks. 2.66 to 2.69 2.65 Knürr PowerTrans Knürr PowerTrans Power Distribution Rack Knürr PowerTrans

More information

Modular PDU Smart metering for your IT

Modular PDU Smart metering for your IT Modular PDU Smart metering for your IT Extremely flexible The modular PDU 2 Rittal modular PDU Modern IT equipment is constantly evolving, requiring permanent adjustments to the IT infrastructure. With

More information

Product Brochure. Eaton epdu G3 Managed

Product Brochure. Eaton epdu G3 Managed Product Brochure Eaton epdu G3 Managed Advanced power management and precision control The Eaton epdu third generation (G3) Managed models build on Eaton s existing state-of-the-art epdu G3 technology

More information

Energy Management Solutions

Energy Management Solutions Energy Management Solutions Metered ipdu (EN1000 Series): Networked, realintroducing the world s most innovative intelligent Power Distribution time input and circuit breaker level monitoring for early

More information

SmartPro LCD 120V 1500VA 900W Line- Interactive UPS, AVR, 2U Rack/Tower, LCD, USB, DB9 Serial, 8 Outlets

SmartPro LCD 120V 1500VA 900W Line- Interactive UPS, AVR, 2U Rack/Tower, LCD, USB, DB9 Serial, 8 Outlets SmartPro LCD 120V 1500VA 900W Line- Interactive UPS, AVR, 2U Rack/Tower, LCD, USB, DB9 Serial, 8 Outlets MODEL NUMBER: SMART1500LCD Highlights Supports a half-load (450W) up to 11.8 min. during power outage

More information

Metered Rack PDU Rack PDU, Metered, Zero U, 10A, 230V, (16) C13

Metered Rack PDU Rack PDU, Metered, Zero U, 10A, 230V, (16) C13 Metered Rack PDU Rack PDU, Metered, Zero U, 10A, 230V, (16) C13 APC Metered Rack PDU, Input: 230V, Input Connections: IEC-320 C14, Cord Length: 10 feet ( 3.05 meters ), Output: 230V, Output Connections:

More information

Power Distribution Units for Data Centers

Power Distribution Units for Data Centers WWW.SIEMON.COM Power Distribution Units for Data Centers PowerMax Power Distribution Units Siemon s PowerMax line of PDUs range from basic and metered for simple, reliable and cost-effective power distribution,

More information

Intelligent Power Distribution

Intelligent Power Distribution Eaton epdu Intelligent Power Distribution Maximise and manage your rack power Maximise and manage your rack power Two key trends have emerged in the data centre: the demand from today s IT equipment for

More information

Intelligent Power Distribution

Intelligent Power Distribution Eaton epdu Intelligent Power Distribution Maximise and manage your rack power Maximise and manage your rack power Two key trends have emerged in the data centre: the demand from today s IT equipment for

More information

ECO PDU PE7108/PE7208

ECO PDU PE7108/PE7208 PE7108/PE7208 ATEN has developed a new generation of green energy power distribution units (PDUs) to effectively increase the efficiency of data center power usage. The PE7108 / PE7208 eco PDUs are intelligent

More information

- Custom solutions alongside standard range. - Innovation, reliability and service are OEC s core values

- Custom solutions alongside standard range. - Innovation, reliability and service are OEC s core values - Custom solutions alongside standard range - Innovation, reliability and service are OEC s core values - OEC is part of Dool Industries, a family owned company established in 1975 - Operating from Groningen,

More information

ECO PDU PE5108/PE5208

ECO PDU PE5108/PE5208 1 NRGence Energy Intelligence Solutions PE5108/PE5208 ATEN has developed a new generation of green energy power distribution units (PDUs) to effectively increase the efficiency of data center power usage.

More information

Managed Rack PDU MPH2 More efficient Simpler Better

Managed Rack PDU MPH2 More efficient Simpler Better Managed Rack PDU MPH2 More efficient Simpler Better MPH2 Managed Rack PDU The newly developed Managed Rack PDU MPH2 TM is a power supply system with monitoring and control functions. Standout features

More information

SmartOnline 240/208/120V 8kVA 5.6kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 4U Rack/Tower, Split-Phase input, Bypass Switch

SmartOnline 240/208/120V 8kVA 5.6kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 4U Rack/Tower, Split-Phase input, Bypass Switch SmartOnline 240/208/120V 8kVA 5.6kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 4U Rack/Tower, Split-Phase input, Bypass Switch MODEL NUMBER: SU8000RT4U Description Tripp Lite 8kVA SmartOnline

More information

G5 PDU Installation Guide

G5 PDU Installation Guide G5 PDU Installation Guide 1 Contents Before You Begin... 3 Overview... 3 Important Safety Information... 3 Required Tools... 5 Section 1 Introduction... 6 Classification Overview... 6 Features... 7 Form

More information

PM Series Power Meter

PM Series Power Meter PM Series Power Meter Quick Setup Guide - PMC-1000, PMC- 1001, PMM-1000, PMB-1960 Safety Information DANGER! HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Follow safe electrical work practices. See

More information

QuickSpecs. HP Performance Optimized Datacenter (POD) 20ce. Overview. Retired

QuickSpecs. HP Performance Optimized Datacenter (POD) 20ce. Overview. Retired Overview The HP Performance-Optimized Data Center (HP POD) is a containerized datacenter equipped with power infrastructure, cooling and IT power distribution. The HP POD can be deployed within weeks instead

More information

Emerson Network Power Rack PDU Solutions Rack Power Distribution For Critical IT Equipment. AC Power For Business-Critical Continuity

Emerson Network Power Rack PDU Solutions Rack Power Distribution For Critical IT Equipment. AC Power For Business-Critical Continuity Emerson Network Power Rack PDU Solutions Rack Power Distribution For Critical IT Equipment AC Power For Business-Critical Continuity Enhanced Performance And Management Of Dynamic IT Spaces IT space is

More information

SmartPro 230V 1.5kVA 1.35kW Line-Interactive Sine Wave UPS, Extended Run, SNMP, Webcard, 2U Rack/Tower, USB, DB9 Serial

SmartPro 230V 1.5kVA 1.35kW Line-Interactive Sine Wave UPS, Extended Run, SNMP, Webcard, 2U Rack/Tower, USB, DB9 Serial SmartPro 230V 1.5kVA 1.35kW Line-Interactive Sine Wave UPS, Extended Run, SNMP, Webcard, 2U Rack/Tower, USB, DB9 Serial MODEL NUMBER: SMX1500XLRT2U Highlights 1.5kVA / 1500VA / 1350W line interactive 2U

More information

IBM 1U Switched and Monitored Power Distribution Units IBM System x at-a-glance guide

IBM 1U Switched and Monitored Power Distribution Units IBM System x at-a-glance guide IBM 1U Switched and Monitored Power Distribution Units IBM System x at-a-glance guide The IBM 1U Switched and Monitored Power Distribution Units (PDUs) make it quick and simple to deploy, protect, and

More information

Configurable power distribution

Configurable power distribution Configurable power distribution 60 150 kva The easy-to-deploy for data centers with custom requirements Configured to order, factoryassembled power distribution for IT equipment in any size data center

More information

Rackmount LCD Console - 1U - 17in Screen - US Keyboard p

Rackmount LCD Console - 1U - 17in Screen - US Keyboard p Rackmount LCD Console - 1U - 17in Screen - US Keyboard - 1080p Product ID: RKCOND17HDEU This 1U LCD console offers a space-saving solution for managing and monitoring your DVI or VGA servers and KVM switches

More information

CS-12HDE444C8 (Master) Key Features. CL-12HDE444C8 (Link)

CS-12HDE444C8 (Master) Key Features. CL-12HDE444C8 (Link) CS-12HDE444C8 (Master) CL-12HDE444C8 (Link) The Server Technology Smart PDU provides local LED input current monitoring, allowing IT personnel to determine safe levels of loading on a per-phase basis while

More information

BCM2 Series Branch Circuit Monitors Quick Setup Guide

BCM2 Series Branch Circuit Monitors Quick Setup Guide BCM2 Series Branch Circuit Monitors Quick Setup Guide Safety Information DANGER! HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Follow safe electrical work practices. See NFPA 70E in the USA, or applicable

More information

SmartPro 230V 1kVA 500W Line-Interactive UPS, Tower, LCD, USB, 6 Outlets

SmartPro 230V 1kVA 500W Line-Interactive UPS, Tower, LCD, USB, 6 Outlets SmartPro 230V 1kVA 500W Line-Interactive UPS, Tower, LCD, USB, 6 Outlets MODEL NUMBER: SMX1000LCD Highlights Corrects under- and overvoltages from 171V to 266V 6 C13 outlets 3 surge-only Interactive LCD

More information

Intelligent infrastructure monitoring for software-defined data centers. Intelligent Power Manager Infrastructure Simplified IT-centric monitoring

Intelligent infrastructure monitoring for software-defined data centers. Intelligent Power Manager Infrastructure Simplified IT-centric monitoring Intelligent infrastructure monitoring for software-defined data centers Intelligent Power Manager Infrastructure Simplified IT-centric monitoring Make more effective management decisions with intelligent

More information

Smart-UPS APC Smart-UPS 750VA USB & Serial RM 1U 120V

Smart-UPS APC Smart-UPS 750VA USB & Serial RM 1U 120V Smart-UPS APC Smart-UPS 750VA USB & Serial RM 1U 120V APC Smart-UPS, 480 Watts / 750 VA,Input 120V / Output 120V, Interface Port DB-9 RS-232, SmartSlot, USB, Rack Height 1 U Includes: CD with software,

More information

Uninterruptible Power Supplies

Uninterruptible Power Supplies Xi Series 1-6kVA True On-Line UPS Features Rack-Mount/Standalone Format Universal Battery Design (Optional 10 year batteries) Dual Mains Input Dual Position Backlit LCD LCD Load Segment Control 2.5kVA

More information

Power Distribution Units for Data Centers

Power Distribution Units for Data Centers BRC_PowerMax_INT_Draft_I.qxp_Layout 1 9/11/17 2:00 PM Page 2 Power Distribution Units for Data Centers WWW.SIEMON.COM PowerMax Power Distribution Units 2 Siemon s PowerMax line of PDUs range from basic

More information

OmniSmart 1500VA 2U Rack/Tower Line-Interactive 120V UPS with LCD display and USB port

OmniSmart 1500VA 2U Rack/Tower Line-Interactive 120V UPS with LCD display and USB port OmniSmart 1500VA 2U Rack/Tower Line-Interactive 120V UPS with LCD display and USB port MODEL NUMBER: OMNI1500LCD Highlights 1500VA / 1.5kVA 2U rack/tower 120V line interactive UPS with LCD display Corrects

More information

20 Amp PanView iq TM (PViQ TM ) Switched and Environmental Power Outlet Units

20 Amp PanView iq TM (PViQ TM ) Switched and Environmental Power Outlet Units 20 Amp PanView iq TM (PViQ TM ) Switched and Environmental Power Outlet Units specifications PViQ Power Outlet Units shall integrate with the Panduit PIM Software Platform to enable intelligent management

More information

Thunderbolt 3 to USB 3.1 Controller Adapter - 1x USB-C, 3x USB-A

Thunderbolt 3 to USB 3.1 Controller Adapter - 1x USB-C, 3x USB-A Thunderbolt 3 to USB 3.1 Controller Adapter - 1x USB-C, 3x USB-A Product ID: TB33A1C This Thunderbolt 3 to USB 3.1 controller adapter offers twice the performance of a traditional 4-port USB 3.1 hub, enabling

More information

SmartPro LCD 120V 1000VA 500W Line- Interactive UPS, AVR, Tower, USB, TEL/DSL/Coax Protection, 8 Outlets

SmartPro LCD 120V 1000VA 500W Line- Interactive UPS, AVR, Tower, USB, TEL/DSL/Coax Protection, 8 Outlets SmartPro LCD 120V 1000VA 500W Line- Interactive UPS, AVR, Tower, USB, TEL/DSL/Coax Protection, 8 Outlets MODEL NUMBER: SMART1000LCD Highlights Supports a basic desktop PC up to 60 min. during power outage

More information

PQube 3. Power Quality, Energy & Environment Monitoring. New Low-Cost, High-Precision

PQube 3. Power Quality, Energy & Environment Monitoring. New Low-Cost, High-Precision New Low-Cost, High-Precision Power Quality, Energy & Environment Monitoring PQube 3 Power Quality Class A Energy Revenue Grade class 0.2s Accuracy Additional AC, DC, and Environment Sensor Channels World

More information

USB VGA KVM Console Extender w/ Serial & Audio Over Cat5 UTP ft

USB VGA KVM Console Extender w/ Serial & Audio Over Cat5 UTP ft USB VGA KVM Console Extender w/ Serial & Audio Over Cat5 UTP - 1000 ft Product ID: SV565UTPUSA The SV565UTPUSA USB VGA KVM Console Extender w/ Serial & Audio Over Cat5 UTP (1000 ft) lets you control a

More information

QuickSpecs. HPE Metered and Switched Power Distribution Units (PDU) Overview

QuickSpecs. HPE Metered and Switched Power Distribution Units (PDU) Overview HPE Metered and Switched Power Distribution Units (PDU) Overview Looking for a power distribution unit that meets the demands of high temperature operating environments and provides monitoring and switching

More information

Technical System Catalogue CMC III Monitoring System

Technical System Catalogue CMC III Monitoring System Technical System Catalogue CMC III Monitoring System CMC III monitoring system CMC III Processing Unit 3 6 1 5 7 4 8 9 10 11 Computer Multi Control (CMC) is an alarm system for network and server enclosures,

More information

SmartOnline V 3kVA 2.7kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 3U Rack, LCD display, USB, DB9 Serial

SmartOnline V 3kVA 2.7kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 3U Rack, LCD display, USB, DB9 Serial SmartOnline 100-127V 3kVA 2.7kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 3U Rack, LCD display, USB, DB9 Serial MODEL NUMBER: SU3000RTXLCD3U Description Tripp Lite Smart Online UPS systems

More information

Prisma II Platform. Optoelectronics

Prisma II Platform. Optoelectronics Optoelectronics Prisma II Platform Description In optical transmission systems, the network platform forms the foundation of the product family. The Prisma II platform provides network operators with the

More information

PE8216/PE8324. Energy Intelligence Solutions

PE8216/PE8324. Energy Intelligence Solutions PE8216/PE8324 As part of its NRGence line, ATEN has developed a new generation of green energy power distribution units (eco PDUs) to effectively increase the efficiency of data center power usage. The

More information

CS-10H0A413H3 (Master) Key Features. CL-10H0A413H3 (Link)

CS-10H0A413H3 (Master) Key Features. CL-10H0A413H3 (Link) CS-10H0A413H3 (Master) CL-10H0A413H3 (Link) The Server Technology Smart PDU provides local LED input current monitoring, allowing IT personnel to determine safe levels of loading on a per-phase basis while

More information

C2W36CE-DQME2M99 (Master) C2X36CE-DQME2M99 (Expansion) Key Features

C2W36CE-DQME2M99 (Master) C2X36CE-DQME2M99 (Expansion) Key Features C2W36CE-DQME2M99 (Master) C2X36CE-DQME2M99 (Expansion) The Server Technology PRO2 Switched PDU provides control of outlet power and local LED input current monitoring, allowing IT personnel to determine

More information

Electronic SD1, AS 8, ASR 14, ASR 20

Electronic SD1, AS 8, ASR 14, ASR 20 Electronic SD1, AS 8, ASR 14, ASR 20 2 Electronic SD1, AS 8, ASR 14, ASR 20 Contents Page List of contents..................................................... 3 Function and characteristics.........................

More information

SmartOnline 120V 3kVA 2.7kW Double- Conversion UPS, 2U Rack/Tower, Extended Run, Network Card Slot, LCD, USB, DB9 Serial

SmartOnline 120V 3kVA 2.7kW Double- Conversion UPS, 2U Rack/Tower, Extended Run, Network Card Slot, LCD, USB, DB9 Serial SmartOnline 120V 3kVA 2.7kW Double- Conversion UPS, 2U Rack/Tower, Extended Run, Network Card Slot, LCD, USB, DB9 Serial MODEL NUMBER: SU3000RTXLCD2U Highlights 3000VA / 3kVA / 2700W on-line double-conversion

More information

ECO PDU. Features. PE5220sA

ECO PDU. Features. PE5220sA ECO PDU PE5220s As part of its NRGence line, ATEN has developed a new generation of green energy power distribution units (PDUs) to effectively increase the efficiency of data center power usage. The NRGence

More information

THE OFFICIAL TRADE JOURNAL OF BICSI

THE OFFICIAL TRADE JOURNAL OF BICSI ICT TODAY THE OFFICIAL TRADE JOURNAL OF BICSI January/February 2017 Volume 38, Number 1 + PLUS + Information Security and ESS in the Age of the Internet of Things + Grounding System Design and Testing

More information

UPS. centric Hot scalable modular 3-phase UPS Delivers 25 up to 200 kva/kw INFINITE POWER. Mission Critical Applications

UPS. centric Hot scalable modular 3-phase UPS Delivers 25 up to 200 kva/kw INFINITE POWER. Mission Critical Applications INFINITE POWER Mission Critical Applications UPS UNINTERRUPTIBLE POWER SUPPLY centric Hot scalable modular 3-phase UPS Delivers 25 up to 200 kva/kw Rack-mountable modules designed for blades, data-center,

More information

UMG 20CM. 20 Channel Branch Circuit Monitoring Device with RCM

UMG 20CM. 20 Channel Branch Circuit Monitoring Device with RCM 20 Channel Branch Circuit Monitoring Device with RCM RCM Harmonics via analysis channel Alarm management GridVis Analysis software 20 current channels Interfaces / communication RS485 RTU Accuracy of measurement

More information

SmartPro 120V 1.05kVA 705W Line-Interactive UPS, Tower, 120V, USB port

SmartPro 120V 1.05kVA 705W Line-Interactive UPS, Tower, 120V, USB port SmartPro 120V 1.05kVA 705W Line-Interactive UPS, Tower, 120V, USB port MODEL NUMBER: SMART1050 Highlights 1.05kVA / 1050VA line interactive tower UPS system 120V output, Corrects brownouts and overvoltages

More information

SmartPro 230V 5kVA 3.75kW Line-Interactive Sine Wave UPS, 3U, Extended Run, Network Card Options, USB, DB9

SmartPro 230V 5kVA 3.75kW Line-Interactive Sine Wave UPS, 3U, Extended Run, Network Card Options, USB, DB9 SmartPro 230V 5kVA 3.75kW Line-Interactive Sine Wave UPS, 3U, Extended Run, Network Card Options, USB, DB9 MODEL NUMBER: SMX5000XLRT3U Highlights 5kVA / 5000VA line interactive 3U rack/tower UPS; Sine

More information

Rittal Cooling Solutions A. Tropp

Rittal Cooling Solutions A. Tropp 1 Rittal Cooling Solutions Presented by Adam Tropp 2 Agenda Cooling Strategies Aisle Containment Chimney Solution Airstream Management Rittal Liquid Cooling Packages Data Monitoring 3 Cooling strategies.

More information

Socomec Netys PR RT U P S TOWER / RACK MOUNT

Socomec Netys PR RT U P S TOWER / RACK MOUNT Socomec Netys PR RT Ideal solution for protecting small servers, networking devices and peripherals. Assures service continuity to critical applications. Designed for professional applications: the sinevawe

More information

Intelligent-Remote Monitoring (3) Power Circuit Environmental Port (4) Power Outlet Level (5) PDU De-Rated Power Watts (W) PDU Nominal.

Intelligent-Remote Monitoring (3) Power Circuit Environmental Port (4) Power Outlet Level (5) PDU De-Rated Power Watts (W) PDU Nominal. Enclosure Power Distribution Units (PDUs) (continued) PDU Selection: Basic, with ocal Monitoring and Intelligent Highly secure access with admin, control and view-only accounts Intuitive Ethernet-based

More information

All power outlet units include 10' power cords, mounting brackets, screws, unit packaging:

All power outlet units include 10' power cords, mounting brackets, screws, unit packaging: 30, 50, and 60 Amp PanView iq TM (PViQ TM ) Switched with Per Outlet Monitoring specifications PViQ Power Outlet Units shall integrate with the Panduit PIM Software Platform to enable intelligent management

More information

6222 Two Door Module Technical Operations Manual

6222 Two Door Module Technical Operations Manual 6222 Two Door Module Technical Operations Manual TABLE OF CONTENTS Specifications...3 Overview...4 Operations...5 Custom Access Mode...5 Standard Access Mode...5 Offline Access Mode...5 Offline Memory...5

More information

Basic In-Line Metered Metered Input. Metered Outlet Switched Managed. Power distribution for IT equipment. epdu. G3 Platform. New

Basic In-Line Metered Metered Input. Metered Outlet Switched Managed. Power distribution for IT equipment. epdu. G3 Platform. New Power distribution for IT equipment Basic In-Line Metered Metered Input Metered Outlet Managed epdu G3 Platform range extension 2017/2018 Outlet grip functionality on standard IEC cable Universal Mounting

More information

Safe share. Application, installation and technical guide for ADRN Service Slice v1.0. ADRN Service Slice 1

Safe share. Application, installation and technical guide for ADRN Service Slice v1.0. ADRN Service Slice 1 Application, installation and technical guide for ADRN Service Slice v1.0 ADRN Service Slice 1 1. Introduction This document is provided to the Network and Security technical teams at the Customer Client

More information

Dell MD1280 Storage Enclosure Getting Started Guide

Dell MD1280 Storage Enclosure Getting Started Guide Dell MD1280 Storage Enclosure Getting Started Guide Regulatory Model: SP-2584, E11J Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your computer.

More information

SmartPro LCD 120V 1.5kVA 900W Line-Interactive UPS, AVR, 2U Rack/Tower, LCD Display, USB, DB9 Serial

SmartPro LCD 120V 1.5kVA 900W Line-Interactive UPS, AVR, 2U Rack/Tower, LCD Display, USB, DB9 Serial SmartPro LCD 120V 1.5kVA 900W Line-Interactive UPS, AVR, 2U Rack/Tower, LCD Display, USB, DB9 Serial MODEL NUMBER: SMART1500LCD Highlights 1500VA / 1.5kVA 2U rack/tower 120V line interactive UPS with LCD

More information

SmartOnline 120V 3kVA 2.4kW Double- Conversion UPS, Tower, Extended Run, Network Card Options, USB, DB9 Serial

SmartOnline 120V 3kVA 2.4kW Double- Conversion UPS, Tower, Extended Run, Network Card Options, USB, DB9 Serial SmartOnline 120V 3kVA 2.4kW Double- Conversion UPS, Tower, Extended Run, Network Card Options, USB, DB9 Serial MODEL NUMBER: SU3000XL Highlights 3000VA / 3kVA / 2400 watt online double-conversion tower

More information

Table of Contents. 1. Introduction Package Contents Function Installation Web Interface... 4

Table of Contents. 1. Introduction Package Contents Function Installation Web Interface... 4 User Manual Table of Contents 1. Introduction... 1 2. Package Contents... 2 3. Function... 3 4. Installation... 2 5. Web Interface... 4 1. Introduction The ServerLink PDU is a network ready device designed

More information

Product brochure. Eaton epdu G3. Simplify installation. Enhance operation. Maximize control.

Product brochure. Eaton epdu G3. Simplify installation. Enhance operation. Maximize control. Product brochure Eaton epdu G3 Simplify installation. Enhance operation. Maximize control. Power distribution made better by Eaton The Eaton epdu G3 rack mounted power distribution units (PDUs) provide

More information

VT608 / Switched PDU with 8 outlets

VT608 / Switched PDU with 8 outlets Switched PDU with Monitoring VT608 / Switched PDU with 8 outlets Device is used for load management and allows to switch on/off or reboot up to 8 outlets. It has built-in temperature sensor, can connect

More information

AVR Series 120V 750VA 450W Ultra-Compact Line-Interactive UPS with USB port

AVR Series 120V 750VA 450W Ultra-Compact Line-Interactive UPS with USB port AVR Series 120V 750VA 450W Ultra-Compact Line-Interactive UPS with USB port MODEL NUMBER: AVR750U Highlights 750VA ultra-compact 120V line interactive UPS Corrects brownouts and overvoltages from 83V to

More information

Powering HP BladeSystem c7000 Enclosures

Powering HP BladeSystem c7000 Enclosures Powering HP BladeSystem c7000 Enclosures HOWTO Abstract... 2 Power draw of HP BladeSystem c7000 Enclosure... 2 Power Distribution...2 Uninterruptible Power Supplies... 6 For more information... 9 Call

More information

IT monitoring. CMC III Monitoring system CMC III system representation CMC III system overview CMC III Processing Unit/Compact...

IT monitoring. CMC III Monitoring system CMC III system representation CMC III system overview CMC III Processing Unit/Compact... IT monitoring Monitoring system system representation...446 system overview...448 Processing Unit/Compact...450 sensors/accessories control units/ sensors...45 Interface for CMC II sensors...45 Access

More information

Smart-UPS XL APC Smart-UPS XL 2200VA RM 3U 120V

Smart-UPS XL APC Smart-UPS XL 2200VA RM 3U 120V Smart-UPS XL APC Smart-UPS XL 2200VA RM 3U 120V APC Smart-UPS XL, 1850 Watts / 1850 VA,Input 120V / Output 120V, Interface Port DB-9 RS-232, USB, SmartSlot, Extended runtime model, Rack Height 3 U Includes:

More information

3300 kw, Tier 3, Chilled Water, 70,000 ft 2

3300 kw, Tier 3, Chilled Water, 70,000 ft 2 [Reference Design 22] 3300 kw, Tier 3, Chilled Water, 70,000 ft 2 DESIGN OVERVIEW Data Center IT Capacity 1100 kw per Data Hall 3 Independent Data Halls Design Application Range This design can be applied

More information

SmartPro 230V 3kVA 2.7kW Line-Interactive Sine Wave UPS, 2U, Extended Run, Network Card Options, LCD, USB, DB9

SmartPro 230V 3kVA 2.7kW Line-Interactive Sine Wave UPS, 2U, Extended Run, Network Card Options, LCD, USB, DB9 SmartPro 230V 3kVA 2.7kW Line-Interactive Sine Wave UPS, 2U, Extended Run, Network Card Options, LCD, USB, DB9 MODEL NUMBER: SMX3000XLRT2UA Highlights 3kVA / 3000VA / 2700W line interactive 2U rack/tower

More information

SmartOnline 208 & 120V 5kVA 4.5kW Double- Conversion UPS, 6U Rack/Tower, Extended Run, Network Card Slot, USB, DB9 Serial

SmartOnline 208 & 120V 5kVA 4.5kW Double- Conversion UPS, 6U Rack/Tower, Extended Run, Network Card Slot, USB, DB9 Serial SmartOnline 208 & 120V 5kVA 4.5kW Double- Conversion UPS, 6U Rack/Tower, Extended Run, Network Card Slot, USB, DB9 Serial MODEL NUMBER: SU5000RT4UTF Highlights 5kVA / 5000VA / 4500 watt online double-conversion

More information

Tripp Lite PDUs POWER DISTRIBUTION UNITS. Reliable rack power distribution for high-density IT environments. Introduction 2-3.

Tripp Lite PDUs POWER DISTRIBUTION UNITS. Reliable rack power distribution for high-density IT environments. Introduction 2-3. POWER DISTRIBUTION UNITS Tripp Lite rack power distribution for high-density IT environments. Introduction 2-3 Basic 4 Metered 5 Monitored 6 Switched 7 ATS 8 Hot-Swap 8 INTRODUCTION Tripp Lite Rack increase

More information

4 Port DVI VGA Dual Monitor KVM Switch USB with Audio & USB 2.0 Hub

4 Port DVI VGA Dual Monitor KVM Switch USB with Audio & USB 2.0 Hub 4 Port DVI VGA Dual Monitor KVM Switch USB with Audio & USB 2.0 Hub Product ID: SV431DDVDUA The SV431DDVDUA 4-port DVI VGA dual monitor KVM switch lets you control 4 Dual Display computers using a single

More information

Quick Start Installation Guide

Quick Start Installation Guide apc/l Quick Start Installation Guide Version A2 Document Part Number UM-201 May 2010 OVERVIEW The apc/l is an intelligent access control and alarm monitoring control panel which serves as a basic building

More information

Data Sheet FUJITSU PRIMECENTER M2 19-inch Racks

Data Sheet FUJITSU PRIMECENTER M2 19-inch Racks Data Sheet FUJITSU PRIMECENTER M2 19-inch Racks Data Sheet FUJITSU PRIMECENTER M2 19-inch Racks 19-inch Industry Standard Rack Systems The trend to consolidation as a result of virtualization and optimization

More information

BC Personal 120V 450VA 280W Standby UPS, Tower, USB port, 3 Outlets

BC Personal 120V 450VA 280W Standby UPS, Tower, USB port, 3 Outlets BC Personal 120V 450VA 280W Standby UPS, Tower, USB port, 3 Outlets MODEL NUMBER: BCPERS450 Highlights 450VA tower 120V standby UPS Maintains AC output during power failures USB port, Status LEDs NEMA

More information

HP UPS R/T3000 G2. Overview. Precautions. Kit contents. Installation Instructions

HP UPS R/T3000 G2. Overview. Precautions. Kit contents. Installation Instructions HP UPS R/T3000 G2 Installation Instructions Overview The HP UPS R/T3000 G2 features a 2U rack-mount with convertible tower design and offers power protection for loads up to a maximum of 3300 VA/3000 W

More information

PowerSwitches MultiPower 7.8

PowerSwitches MultiPower 7.8 MultiPower 7.8 Central power sources & devices for remote power switching G&D IF IT S KVM The company Guntermann & Drunck is regarded as a leading manufacturer of digital and analogue KVM equipment used

More information

AVR Series 120V 550VA 300W Ultra-Compact Line-Interactive UPS with USB port

AVR Series 120V 550VA 300W Ultra-Compact Line-Interactive UPS with USB port AVR Series 120V 550VA 300W Ultra-Compact Line-Interactive UPS with USB port MODEL NUMBER: AVR550U Highlights 550VA ultra-compact 120V line interactive UPS Corrects brownouts and overvoltages from 83V to

More information

PRODUCT PRESENTATION PROTECT C (6-10kVA) DATA & IT, C-UPS

PRODUCT PRESENTATION PROTECT C (6-10kVA) DATA & IT, C-UPS PRODUCT PRESENTATION PROTECT C (6-10kVA) DATA & IT, C-UPS Office, SoHo, IT segment Compact UPS Home, SoHo Surge protection AEG S COMMERCIAL COMPACT-UPS PRODUCT PORTFOLIO AND FIELD APPLICATION PROTECT BASIC

More information

SmartPro 120V 3kVA 2.88kW Line-Interactive Sine Wave UPS, 2U, Extended Run, Network Card Options, LCD, USB, DB9

SmartPro 120V 3kVA 2.88kW Line-Interactive Sine Wave UPS, 2U, Extended Run, Network Card Options, LCD, USB, DB9 SmartPro 120V 3kVA 2.88kW Line-Interactive Sine Wave UPS, 2U, Extended Run, Network Card Options, LCD, USB, DB9 MODEL NUMBER: SMART3000RMXL2U Highlights 3kVA / 3000VA / 2880W line interactive 2U rack/tower

More information

PQube 3. Power Quality, Energy & Environment Monitoring. New Low-Cost, High-Precision

PQube 3. Power Quality, Energy & Environment Monitoring. New Low-Cost, High-Precision Power Sensors Ltd New Low-Cost, High-Precision Power Quality, Energy & Environment Monitoring PQube 3 Power Quality Class A Edition 3 Energy Revenue Grade class 0.2/0.2s Accuracy Additional AC, DC, and

More information

10-Port USB 3.0 Hub with Charge and Sync Ports - 2 x 1.5A Ports

10-Port USB 3.0 Hub with Charge and Sync Ports - 2 x 1.5A Ports 10-Port USB 3.0 Hub with Charge and Sync Ports - 2 x 1.5A Ports Product ID: ST103008U2C This 10-port USB 3.0 hub enhances your system s capabilities by providing fast-charging for mobile devices, plus

More information

Agilent I/O Hardware for PC-to-Instrument Connection Data Sheet

Agilent I/O Hardware for PC-to-Instrument Connection Data Sheet Agilent I/O Hardware for PC-to-Instrument Connection Data Sheet Agilent connectivity software Choose the best way to connect your PC to GPIB and RS-232 instruments Take advantage of PC-standard interfaces

More information

Power distribution solutions for the ProLiant DL580 G2 server

Power distribution solutions for the ProLiant DL580 G2 server Power distribution solutions for the ProLiant DL580 G2 server Introduction... 2 Symbols in text... 2 Executive summary... 2 Glossary... 2 ProLiant DL580 G2 server power requirements... 3 Power distribution

More information

Smart-UPS On-Line. 2 nd Generation 3-10 kva Offer Technical Overview

Smart-UPS On-Line. 2 nd Generation 3-10 kva Offer Technical Overview Smart-UPS On-Line 2 nd Generation 3-10 kva Offer Technical Overview Generation Comparison Feature SURT SRT Double Conversion On-Line Topology Rack Tower Convertible Smart Slot Automatic Bypass Hot Swap

More information

Smart-UPS APC Smart-UPS 2200VA RM 3U 120V/230V In 120V Out

Smart-UPS APC Smart-UPS 2200VA RM 3U 120V/230V In 120V Out Smart-UPS APC Smart-UPS 2200VA RM 3U 120V/230V In 120V Out APC Smart-UPS, 1600 Watts / 2200 VA,Input 120V, 230V / Output 120V, Interface Port DB-9 RS-232, SmartSlot, Rack Height 3 U Includes: CD with software,

More information