DESIGN GUIDE FOR INFINITY SYSTEMS
|
|
- Geoffrey Horton
- 6 years ago
- Views:
Transcription
1 Doc Rev B DESIGN GUIDE FOR INFINITY SYSTEMS WITH STAND ALONE OR MULTI-LINK LINK FIRMWARE
2 TABLE OF CONTENTS 1. CABINET DIMENSIONS WIRE CHART...3 A. CABLING TO THE MAIN PROCESSOR BOARD... 3 B. CABLING TO THE TELEPHONE INTER FACE BOARD... 4 C. CABLING BETWEEN UNITS WITH DUAL SHORT HAUL MODEMS... 4 D. CABLING BETWEEN UNITS WITHOUT DUAL SHORT-HAUL MODEMS... 4 E. CABLING FOR ADDITIONAL FEATURES...4 F. CABLING FOR FACTORY-SUPPLIED VIDEO CAMERA OPTION DIMENSIONAL DRAWINGS OF INFINITY...6 A. INFINITY L SURFACE MOUNT SYSTEM (SHOWN WITH OPTIONAL CCTV)... 6 B. INFINITY L FLUSH MOUNT SYSTEM... 7 C. INFINITY M SURFACE MOUNT SYSTEM (SHOWN WITH OPTIONAL CCTV)... 8 D. INFINITY M WITH CAMERA FLUSH MOUNT SYSTEM... 9 E. INFINITY S SURFACE MOUNT SYSTEM (SHOWN WITH OPTIONAL CCTV) F. INFINITY S FLUSH MOUNT SYSTEM G. INFINITY DI SURFACE MOUNT SYSTEM H. INFINITY DI FLUSH MOUNT SYSTEM I. INFINITY B SYSTEM J. CAMERA MOUNTING ILLUSTRATION OF PROCESSOR BOARDS...16 A. MAIN PROCESSOR BOARD (REVISIONS E THROUGH F ) B MODEL TELEPHONE INTERFACE BOARD C. AUXILIARY RELAY MODULE BOARD D POWER SUPPLY BOARD IMPORTANT: The Sentex Systems, Inc. warranty on this system is conditioned upon Sentex Systems, Inc. being paid in full for this equipment. The warranty will not be honored until such payment is received by Sentex Systems, Inc. Copyright 2002 All Rights Reserved This document is protected by copyright and may not be copied or adapted without prior written consent of Sentex Systems, Inc. This document contains the information proprietary to Sentex and such information may not be distributed without the prior written consent of Sentex. The software and firmware included in the Sentex Infinity system as they relate to this documentation are also protected by copyright and contain information proprietary to Sentex. Sentex Systems Chatsworth, CA Visit us at The purpose of this guide is to assist you in meeting any specification requirements you may encounter in installing an Infinity system. The information enclosed in this manual is to be used for reference purposes only and is not intended to be an installation or programming manual. Page 2 of 19 Doc Rev B
3 1. CABINET DIMENSIONS TYPE OF SYSTEM HEIGHT WIDTH DEPTH Infinity L or DI Surface Mount /16 4 1/4 Flush Mount Back Box 21 1/4 16 3/4 3 3/16 Flush Mount Bezel 23 11/ /16 Infinity M Surface Mount /4 4 1/4 Flush Mount Back Box 16 7/ /4 3 1/4 Flush Mount Bezel 18 3/4 14 1/2 Infinity S Surface Mount /4 3 1/4 Flush Mount Back Box 16 7/ /4 2 1/4 Flush Mount Bezel 18 3/4 14 1/2 Infinity B: /4 2. WIRE CHART PLEASE NOTE: If the wires you are pulling for this installation are going to be run through an indoor, weather-proof location, it is acceptable to use unshielded cable. If the wires are going to be run through an outdoor location, we recommend that you use shielded cable. Recommendations for both types of cable are provided where needed. A. CABLING TO THE MAIN PROCESSOR BOARD Cabling to the Main Processor Board Type of Wire Recommendations From the power transformer or power supply 2 conductor cable See chart below: 120 VAC outlet From the door strike or the door strike 2 conductor cable See specifications for power supply the device you are installing. DC POWER WIRE SIZE DISTANCE AC POWER WIRE SIZE 18 AWG 30' and under 14 AWG 16 AWG 30'-75' 12 AWG 12 AWG 75'-150' AWG 150'-250' PLEASE NOTE: If you are using the larger sizes of cable (i.e., 12 awg or 10 awg), you may experience problems inserting the wires into the terminal block. If you encounter this problem, you can connect a awg wire (with the use of a wire nut) to each end of the power cable, as long as the smaller gage wire is under 12 inches in length. Rev B Doc Page 3 of 19
4 B. CABLING TO THE TELEPHONE INTER FACE BOARD Cabling to the Telephone Interface Board Type of Wire Recommendations From the telephone company jack 2 conductor, Shielded-Belden # to 22 awg cable Unshielded-Belden #8740 C. CABLING BETWEEN UNITS WITH DUAL SHORT HAUL MODEMS (Multi-Link Systems only) Type of Wire Recommendations From LINE 2 on the first unit and 2 conductor, 16 to 24 awg Shielded-Belden #9501 LINE 1 on the second unit (5000 ft. max.) twisted pair cable Unshielded-Belden #8740 D. CABLING BETWEEN UNITS WITHOUT DUAL SHORT-HAUL MODEMS (Multi-Link Systems only) Type of Wire Recommendations From TB3 on the first unit and 5 conductor, Shielded-Belden #9929 TB2 on the second unit (50 ft. max.) 18 to 24 awg cable Unshielded-Belden #8445 E. CABLING FOR ADDITIONAL FEATURES On an Infinity System Type of Wire Recommendations From a computer terminal 3 conductor Use shielded cable only to the Main Processor Board (50 ft. max.) 16 to 24 awg cable Shielded-Belden #9925 From a printer 3 conductor Use shielded cable only to the Main Processor Board (50 ft. max.) 16 to 24 awg cable Shielded-Belden #9925 From a Stand-Alone Modem 3 conductor Use shielded cable only to the Main Processor Board (50 ft. max.) 18 to 24 awg cable Shielded-Belden #9925 From a Remote Keypad 7 conductor Use shielded cable only to the Main Processor Board (500 ft. max.) 20 to 24 awg cable Shielded-Belden #9932 From a Wiegand, Barium Ferrite, Proximity, or Clikcard card reader to the 5 conductor Use shielded cable only Main Processor Board (500 ft. max.) 24 awg cable Shielded-Belden #9929 On a Multi-Link System Type of Wire Recommendations Between a Computer Terminal 3 conductor Use shielded cable only and the first unit of the system (50 ft. max.) 18 to 24 awg cable Shielded-Belden #9925 Between A Computer Terminal 2 conductor, Use unshielded cable only and a Stand-Alone Short Haul Modem (50 ft. max.) 16 to 24 awg, Unshielded-Belden #8740 twisted pair cable Between a Printer and the 3 conductor Use shielded cable only first (or last) unit of the system (50 ft. max.) 18 to 24 awg cable Shielded-Belden #9925 Between a Printer and a 2 conductor, Use unshielded cable only Stand-Alone Short-Haul Modem (50 ft. max.) 16 to 24 awg, Unshielded-Belden #8740 twisted pair cable Between a Printer and 2 conductor Use shielded cable only the AUX port of a terminal (50 ft. max.) 18 to 24 awg cable Shielded-Belden #9501 Page 4 of 19 Doc Rev B
5 On a Multi-Link System (Continued) Type of Wire Recommendations Between an External Telephone Modem 3 conductor Use shielded cable only and the first unit of the system (50 ft. max.) 18 to 24 awg cable Shielded-Belden #9925 Between an External Telephone Modem 2 conductor, Use unshielded cable only and a Stand-Alone Short-Haul Modem (50 ft. max.) 16 to 24 awg, Unshielded-Belden #8740 twisted pair cable Between a Remote Keypad 7 conductor Use shielded cable only and a unit within the system (500 ft. max.) 20 to 24 awg cable Shielded-Belden #9932 Between a Wiegand, Barium Ferrite, Proximity, or Clikcard card reader 5 conductor Use shielded cable only and a unit within the system (500 ft. max.) 24 awg cable Shielded-Belden #9929 F. CABLING FOR FACTORY-SUPPLIED VIDEO CAMERA OPTION Cabling for Factory-Supplied Video Camera Option From the separate power transformer at the 120 VAC outlet Between the video output and a Video Monitor (1000 ft. max max length based on monitor with.25 volt p-p. composite signal sensitivity) Type of Wire Recommendations 2 conductor cable See chart below: Single Conductor 75 Ohm Cable: Belden #9240 or equiv. RG-59/u coaxial cable BNC Connectors: Amphenol # or equiv. DC POWER WIRE SIZE DISTANCE AC POWER WIRE SIZE 18 AWG 30' and under 18 AWG 18 AWG AWG 18 AWG AWG 16 AWG AWG 12 AWG AWG Rev B Doc Page 5 of 19
6 3. DIMENSIONAL DRAWINGS OF INFINITY A. INFINITY L SURFACE MOUNT SYSTEM (SHOWN WITH OPTIONAL CCTV) This line drawing is intended for dimensional reference purposes only and is not intended to be an actual drawing of the Infinity L system itself. NOTE: Camera is optional. Page 6 of 19 Doc Rev B
7 B. INFINITY L FLUSH MOUNT SYSTEM FLUSH MOUNT BOX This line drawing is intended for dimensional reference purposes only and is not intended to be an actual drawing of the Infinity L Flush Mount system itself. Rev B Doc Page 7 of 19
8 C. INFINITY M SURFACE MOUNT SYSTEM (SHOWN WITH OPTIONAL CCTV) 11 3/4" 2 X 20 LCD Display Enclosure Lock Speaker Camera Keypad # Postal Lock Microphone 16.0" 3 1/2" 4 1/4" 3/4 1564F1 FRONT VIEW SIDE VIEW This line drawing is intended for dimensional reference purposes only and is not intended to be an actual drawing of the Infinity M system itself. NOTE: Camera is optional. Page 8 of 19 Doc Rev B
9 D. INFINITY M FLUSH MOUNT SYSTEM 3 1/4" 2 1/4" 3 3/4" 5 1/4" 1.0" 7 1/4" 16 7/16" 7.0" 1.0" 1564F2 12 1/4" FRONT VIEW 7/8" 5 1/8" 5 1/8" 1 1/8" REAR VIEW FLUSH MOUNT BOX This line drawing is intended for dimensional reference purposes only and is not intended to be an actual drawing of the Infinity M Flush Mount system itself. Rev B Doc Page 9 of 19
10 E. INFINITY S SURFACE MOUNT SYSTEM 11 3/4" Small LCD Display Enclosure Lock Keypad # Microphone 16.0" Speaker Postal Lock 2 1/2" 3/4" 3 1/4" 1114F7 FRONT PANEL SIDE VIEW This line drawing is intended for dimensional reference purposes only and is not intended to be an actual drawing of the Infinity S system itself. Page 10 of 19 Doc Rev B
11 F. INFINITY S FLUSH MOUNT SYSTEM FLUSH MOUNT BOX This line drawing is intended for dimensional reference purposes only and is not intended to be an actual drawing of the Infinity S Flush Mount system itself. Rev B Doc Page 11 of 19
12 G. INFINITY DI SURFACE MOUNT SYSTEM This line drawing is intended for dimensional reference purposes only and is not intended to be an actual drawing of the Infinity DI system itself. Page 12 of 19 Doc Rev B
13 H. INFINITY DI FLUSH MOUNT SYSTEM FLUSH MOUNT BOX This line drawing is intended for dimensional reference purposes only and is not intended to be an actual drawing of the Infinity DI Flush Mount system itself. Rev B Doc Page 13 of 19
14 I. INFINITY B SYSTEM This line drawing is intended for dimensional reference purposes only and is not intended to be an actual drawing of the Infinity B system itself. Page 14 of 19 Doc Rev B
15 J. CAMERA MOUNTING This drawing is provided for your information only. Side View Rev B Doc Page 15 of 19
16 4. ILLUSTRATION OF PROCESSOR BOARDS A MAIN PROCESSOR BOARD (REVISION H ) KEYPAD LIGHT 12V AC/ 13.5V DC POWER GROUND SCREW CLEAR TO SEND RS232 OUT GROUND RS232 IN REQUEST TO SEND CLEAR TO SEND RS232 OUT GROUND RS232 IN REQUEST TO SEND LED A A READER DATA 1 A READER DATA 0 +5 VDC GROUND +12VDC READER POWER LED B B READER DATA 1 B READER DATA 0 +5 VDC GROUND STATUS LINE 3 COMMON STATUS LINE 4 HEATER A TB1 J19 J18 TB2 TB4 TB6 CTS OUT GND RS232 IN PORT 1 RTS TB3 CTS OUT GND RS232 IN PORT 2 IN HI RTS GRN RED LED A A RDR 1 A RDR 0 +5VDC GND TB5 LED B B RDR 1 B RDR 0 +5VDC GND TB7 +12VDC RDR POWER STATUS 3 COM STATUS 4 RED LO FAN B FAN A J17 J3 SMALL DISPLAY CONNECTOR J16 J1 LARGE DISPLAY CONNECTOR RS232 BAUD SEL MONTIOR CLEAR STATUS LINE 1 COMMON STATUS LINE 2 COMMON NOR. OPEN NOR. CLOSED COMMON NOR. OPEN NOR. CLOSED COMMON NOR. OPEN NOR. CLOSED COMMON NOR. OPEN NOR. CLOSED TB8 STATUS 1 COM STATUS 2 TB9 COM NO NC TB10 COM NO NC TB11 COM NO NC TB12 COM NO NC RELAY 2 RELAY 4 RELAY 1 RELAY 3 HANDHELD PROGRAMMER CONNECTION HAND HELD TERMINAL J14 MAIN KEYPAD A KEYPAD J7 CONTRAST ADJUSTMENT POT J9 TEMP SENSE CONTRAST ADJ REMOTE A KEYPAD TB14 REMOTE B KEYPAD TB F17 Page 16 of 19 Doc Rev B
17 B MODEL TELEPHONE INTERFACE BOARD Telephone Interface Board (SN ) LINE RING OFF HOOK CLICK DETECT CLICK LEVEL VR3 CLICK LEVEL SPEAKER LEVEL VR4 PANEL SPEAKER J1 Daughter Board (SN ) HANDSET TB1 LINE BAL 1 LINE BAL 2 MIC SENS PANEL MIC TELCO LINE 1564F3 GROUND Rev B Doc Page 17 of 19
18 C. AUXILIARY RELAY MODULE BOARD Page 18 of 19 Doc Rev B
19 D POWER SUPPLY BOARD WITH BOARD MOUNT CAMERA IMPORTANT NOTE: Do not use the same power supply for this board as for the telephone entry system. The power inputs must be isolated. Rev B Doc Page 19 of 19
INSTALLATION INSTRUCTIONS FOR THE MINI-KEY SYSTEM. Doc Rev B
INSTALLATION INSTRUCTIONS FOR THE MINI-KEY SYSTEM Doc. 6001051 Rev B Page 2 of 7 Doc 6001051 Rev B IMPORTANT NOTICES The Mini-Key system is a very reliable and easy to use system. However, damage could
More informationINSTALLATION INSTRUCTIONS FOR THE "LP" MODEL OVATION SYSTEM. Doc Rev B
INSTALLATION INSTRUCTIONS FOR THE "LP" MODEL OVATION SYSTEM Doc. 6001073 Rev B Page 2 of 31 Doc. 6001073 Rev B IMPORTANT NOTICE Make sure you know the local telephone tariff arrangements before installing
More informationDoc Rev B CROWN JEWEL TELEPHONE ENTRY SYSTEM INSTALLATION INSTRUCTIONS
Doc.. 6001145 Rev B CROWN JEWEL TELEPHONE ENTRY SYSTEM INSTALLATION INSTRUCTIONS TABLE OF CONTENTS IMPORTANT NOTICES... 3 INSTALLATION TIPS... 3 PART 1 PULLING CABLES... 4 A. WIRE INFORMATION... 4 B.
More informationDoc Rev B INSTALLATION INSTRUCTIONS FOR ALL. Infinity TELEPHONE ENTRY SYSTEMS (EXCEPT THOSE WITH MULTI-LINK FIRMWARE)
Doc. 6001019 Rev B INSTALLATION INSTRUCTIONS FOR ALL Infinity TELEPHONE ENTRY SYSTEMS (EXCEPT THOSE WITH MULTI-LINK FIRMWARE) TABLE OF CONTENTS IMPORTANT NOTICES...1 INSTALLATION TIPS...1 PART 1 ARRANGING
More informationInstallation Instructions for the AUTOcard-SA System
Installation Instructions for the AUTOcard-SA System IMPORTANT NOTICE The AUTOcard-SA system is a very reliable and easy to use system. However, damage could occur if it is installed incorrectly. In particular,
More informationQuick Start Installation Guide
apc/l Quick Start Installation Guide Version A2 Document Part Number UM-201 May 2010 OVERVIEW The apc/l is an intelligent access control and alarm monitoring control panel which serves as a basic building
More informationDoc Rev B INSTALLATION INSTRUCTIONS FOR THE OVATION SYSTEMS
Doc.. 6001072 Rev B INSTALLATION INSTRUCTIONS FOR THE "S" AND "V" MODEL OVATION SYSTEMS IMPORTANT NOTICE Make sure you know the local telephone tariff arrangements before installing this system. In some
More informationLandmark Upgrade Kit Installation Instructions
Landmark Upgrade Kit Installation Instructions REMOVING THE LANDMARK BOARD 1 REMOVE POWER FROM UNIT. 2 Disconnect ALL board connections by removing the associated blue blocks (see Figure 1). Include the
More informationGUIDE TO THE INFINITY
Doc 6001029 Rev C GUIDE TO THE INFINITY TELEPHONE ENTRY SYSTEM PART 1 THE INFINITY SYSTEM The Infinity system is one of the most powerful and flexible access control systems in existence today. Yet, its
More informationDoc Rev B INSTALLATION INSTRUCTIONS FOR THE "NO PHONE BILL" INTERFACE
Doc - 6001003 Rev B INSTALLATION INSTRUCTIONS FOR THE "NO PHONE BILL" INTERFACE IMPORTANT NOTICES The "No Phone Bill Interface" (hereafter referred to as the "NPBI") contains static sensitive parts. To
More informationSection A5. Standard Telephone Entry Systems. This Price Schedule is effective April 1, Date Page Comment
April 2015 PRICE SCHEDULE A 2.0 Section A5 This Price Schedule is effective April 1, 2015. Date Page Comment 4-1-15 All April, 2015 Price Schedule update. Prices and specifications subject to change without
More informationInstalling the DX LCD Display
DX LCD Display User s Guide 3-1 Chapter 3 Installing the DX LCD Display Introduction Use the DX LCD Display as either a portable device, or permanently mount it in a panel or on the wall. For panel and
More informationTX3 Series TELEPHONE ACCESS SYSTEMS. Installation and Operation Manual
TX3 Series TELEPHONE ACCESS SYSTEMS Installation and Operation Manual Version 1.00.5 Mircom 1 (110) 2 (110) Telephone Access System Installation and Operation Manual Version 1.00.5 Contents 1 Introduction
More informationINSTRUCTIONS FOR THE INSTALLATION OF THE INFINITY "L" DISPLAY HOOD (INTO PREVIOUSLY INSTALLED INFINITY "L" SYSTEMS)
Doc. 6001025 Rev B INSTRUCTIONS FOR THE INSTALLATION OF THE INFINITY "L" DISPLAY HOOD (INTO PREVIOUSLY INSTALLED INFINITY "L" SYSTEMS) Rev. B Doc. 6001025 Page 1 of 13 IMPORTANT NOTICE This document covers
More informationPXL-250 Tiger Controller
PXL-0 Tiger Controller This quick start guide is made up of specification sheets, a DO/DON T list, basic installation drawings, first time power-on instructions, and short descriptions of key terms and
More informationJanuary 2013 PRICE SCHEDULE A 2.0. Access Plus Telephone Entry & Access Control
January 2013 PRICE SCHEDULE A 2.0 Section A4 Date Page Comment 1 1 13 All January, 2013 Price Schedule update. 2 13 13 6 Removed 1812 092 from 1812 145 kit. Added 1812 092 to 1812 147 kit. 2 13 13 9 P/N
More informationPLEASE READ INSTRUCTIONS CAREFULLY BEFORE INSTALLATION!
TUC2 / TUCH2 Model Series Installation Instructions PLEASE READ INSTRUCTIONS CAREFULLY BEFORE INSTALLATION! APPLICATION The TUC2 provides temperature space monitoring with a backlit LCD. The TUCH2 provides
More informationCustom Controller Installation Instructions
MODEL CUSTOM CONTROLLER HARDWARE CODE MAX ALLOWABLE AMBIENT TEMP: 70 C (158 F) THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES. OPERATION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS: 1) THIS DEVICE MAY
More informationUC-2000 Installation Manual Unicorn Computers Technology Limited
UC2000 Installation Manual Copyright 2003. All rights reserved. Table of Contents Specifications 2 Enclosure for the UC2000 Controller 3 Unicorn Access Control System Configuration 4 UC2000 Controller
More information508 SERIES MICROPHONE STATIONS
INSTALLATION INSTRUCTIONS GENERAL DESCRIPTION The IED 508 Series microphone stations utilize either a two or three layer stacked printed circuit board design in which, with the exception of the desktop
More informationPROGRAMMING AND USE INSTRUCTIONS FOR THE OVATION SYSTEM
Doc. 6001012 Rev B PROGRAMMING AND USE INSTRUCTIONS FOR THE OVATION SYSTEM ALPHA COMMUNICATIONS 42 Central Drive Farmingdale NY 11735-1202 Phone: 631-777-5500 - Fax: 631-777-5599 IMPORTANT NOTICE If the
More informationOwner s Manual. 1833, 1834, 1835, 1837 PC Programmable Telephone Entry and Access Control Systems
Owner s Manual 1833, 1834, 1835, 1837 PC Programmable Telephone Entry and Access Control Systems DoorKing, Inc. 120 Glasgow Avenue Inglewood, California 90301 U.S.A. Phone: 310-45-0023 Fax: 310-41-158
More information6222 Two Door Module Technical Operations Manual
6222 Two Door Module Technical Operations Manual TABLE OF CONTENTS Specifications...3 Overview...4 Operations...5 Custom Access Mode...5 Standard Access Mode...5 Offline Access Mode...5 Offline Memory...5
More informationApril 2015 PRICE SCHEDULE A 2.0 Stand-Alone Access Control
Section A6 This Price Schedule is effective April 1, 2015. Date Page Comment 4-1-15 All April, 2015 Price Schedule update. 5-8-15 3 Removed model 1503. Added models 1509 / 1515 (Pg 15) to the TOC. 8-10-15
More informationSuprex RS-485 SPX-7500 Wired Reader-Extender
Suprex RS-485 SPX-7500 Wired Reader-Extender Product Manual SPX-7500_MAN_181206 Cypress Integration Solutions 35 Years of Access Control Ingenuity CypressIntegration.com 2018 Cypress Computer Systems 1778
More informationClick Save to return to the main Setup screen.
ON-SITE Setup Guide Thank you for purchasing the ON-SITE. This guide will assist you in the setup of the system. You can call for FREE technical support to get help anytime at 757-258-0910. Please note,
More informationOwner s Manual. Models 1503 and 1504 Basic Stand Alone Digital Keypad Entry Devices
Owner s Manual Models 1503 and 1504 Basic Stand Alone Digital Keypad Entry Devices DoorKing, Inc. 120 Glasgow Avenue Inglewood, California 90301 U.S.A. Phone: 310-645-0023 Fax: 310-641-1586 www.doorking.com
More informationOwner s Manual PC Programmable Multi-Door Access Controller
Owner s Manual PC Programmable Multi-Door Access Controller DoorKing, Inc. 0 Glasgow Avenue Inglewood, California 00 U.S.A. Phone: 0--00 Fax: 0-- www.doorking.com P/N -0 REV P, / Copyright 00 DoorKing,
More informationZodiac FR100 TM INSTALLATION MANUAL
Zodiac FR100 TM INSTALLATION MANUAL June 2014 Table of Contents INTRODUCTION... 3 SPECIFICATIONS... 4 Diodes... 5 Terminal Strips and Cable... 5 READER LAYOUT... 6 READER INSTALLATION... 7 Mounting Plate...
More informationHardware User s Manual. Digital Video Motion Detector DVMD1-X
Hardware User s Manual Digital Video Motion Detector DVMD1-X Version 010 Revision A July, 2004 2395 Kenwood Drive Boulder, CO 80303 (303) 543-0440 TECHNICAL SPECIFICATIONS VENDOR Radiant Inc. http://www.dvmd.com
More informationSmartLock Controller INSTALLATION MANUAL
SmartLock Controller INSTALLATI MANUAL November 2015 Table of Contents INTRODUCTI... 3 Diodes... 4 Terminal Strips and Cable... 5 SPECIFICATIS... 6 SMARTLOCK CTROLLER LAYOUT... 8 LED Indicators... 9 Mounting...
More informationSmartLock Pro INSTALLATION MANUAL
SmartLock Pro INSTALLATI MANUAL July 2010 Cutting edge simplicity Table of Contents INTRODUCTI... 3 Diodes... 3 Power Supply Notice... 3 Terminal Strips and Cable... 4 SPECIFICATIS... 5 SMARTLOCK CTROLLER
More informationCYPRESS " " EXP SPX Expansion interface! modules EXP-2000_MAN_0314
CYPRESS EXP-2000 SPX Expansion interface! modules The EXP-2000 provides additional Door/Panel interface points to most SPX products. The EXP-2000 uses a local RS-485 network through an SPX gateway device.
More information5000 Series Audio/Video System Installation & Service Manual
5000 Series Audio/Video System Installation & Service Manual 08-315G (3/25/13) Table of Contents Description...3 System Configuration...3 Cable Considerations...4 Matrix Installation...4 Matrix / System
More information2000 Series e/em Style Keypad Installation and Programming Manual
2000 Series e/em Style Keypad Installation and Programming Manual Document Number: 6054022 Revision: 0 Date: 12/21/06 Table of Contents Table of Contents Section 1: Introduction... 6 1 Product Description...6
More informationTwo Door Controller GEN-045
Australian Owned, Designed and Manufactured Two Door Controller GEN-045 Genesis Electronics Australia Pty Ltd www.genesiselectronics.com.au Distributed by: Genesis reserves the right to change or modify
More informationTAC I/NETTM 1284, 1280, Security Control Unit
TAC I/NETTM The SCU () family of modular, stand-alone controllers are basic building blocks of the I/NET Seven Security Management System, and provide a flexible mix of door control and alarm monitoring
More informationBioPointe Reader Installation Guide
BioPointe Reader Installation Guide What s in this Guide Installation Steps 1 Key Parts of the BioPointe Reader 2 Cabling Requirements 3 Power Connection 3 PXL-500W Wiegand Controller Connection 3 Serial
More informationACTentry A5 Kit. ACTentry A5 Entry Panel. Audio Door Entry with Access Control. Audio Door Entry & Access Control Kit Features
Audio Door Entry with Access Control ACTentry A5 Kit Audio Door Entry & Access Control Kit Each kit comprises a door entry panel intercom power supply unit ACTEntryA5ICOM-K ACTentry A5 Entry Panel Audio
More informationConnector and Cable Specifications
APPENDIX B This appendix describes the pinouts and cabling requirements for the interfaces and cables used on the Cisco ubr925 cable access router. All connectors for these interfaces are on the rear-panel,
More informationTELEPHONE ENTRY SYSTEMS PARTS U.S. PRICE LIST
TELEPHONE ENTRY SYSTEMS PARTS U.S. PRICE LIST EFFECTIVE DECEMBER 1, 2011 TELEPHONE ENTRY Spectrum........................................................2 Spectrum DI (Vista)................................................4
More informationNetGen Hardware Installation Guide. for NetGen Ethernet Door Controllers
NetGen Hardware Installation Guide for NetGen Ethernet Door Controllers 0613 Table of Contents BLUEWAVE SYSTEM OVERVIEW...2 THE WI-FI LOCK AND SECURITY COMPANY...2 NETGEN DOOR CONTROLLERS...2 INSTALLATION
More informationOwner s Manual PC Programmable Multi-Door Access Controller
Owner s Manual PC Programmable Multi-Door Access Controller DoorKing, Inc. 0 Glasgow Avenue Inglewood, California 00 U.S.A. Phone: 0--00 Fax: 0-- www.doorking.com P/N -0 REV W, 0/ Copyright 00 DoorKing,
More informationMounting and Connections
Receipt of the GPU-2000R When you receive the GPU-2000R, examine it carefully for shipping damage. If any damage or loss is evident, file a claim at once with the shipping agent and promptly notify the
More informationJanuary 2013 PRICE SCHEDULE A 2.0. PC Programmable Telephone Entry & Access Control
January 2013 PRICE SCHEDULE A 2.0 Section A3 Date Page Comment 10 1 13 All October, 2013 Price Schedule update. 1 25 13 18 Added part numbers to TagMaster products. 2 13 13 9 Removed wireless wiegand devices
More informationABB Drives. User s Manual RS-485 Adapter Board FRSA-00
ABB Drives User s Manual RS-485 Adapter Board FRSA-00 Table of Contents 1 INTRODUCTION... 2 1.1 Overview... 2 1.2 Technical Data of RS-485 Link... 2 1.3 RS-485 Bus Topology... 2 2 INSTALLATION... 2 2.1
More informationInstallation & Operation Guide
& Operation Guide KMD-7301/7301C Direct Digital Controller For Air Handling Applications 880-019-02C KMD 7301 and KMD 7301C Direct Digital Controller & Operation Guide Introduction This section provides
More informationSecurity Management System by Diebold, Inc. LINX System Hardware Installation Guide
Security Management System by Diebold, Inc. LINX System Hardware Installation Guide INSTALLATION GUIDE LINX Integrated Security System WSD 2000 Weatherized Status Display Table of Contents Introduction
More informationVertX. V100, V200 and V300. Installation Guide Barranca Parkway Irvine, CA USA. November Rev A.1
15370 Barranca Parkway Irvine, CA 92618 USA VertX V100, V200 and V300 Installation Guide November 2011 6080-930 Rev A.1. Contents Introduction... 3 Parts List... 3 Product Specifications... 3 Cable Specifications...
More informationJanuary 2013 PRICE SCHEDULE A 2.0 PC Programmable Telephone Entry & Access Control. PC Programmable Telephone Entry & Access Control
January 2013 PRICE SCHEDULE A 2.0 Section A3 Date Page Comment 10-1-13 All October, 2013 Price Schedule update. 1-25-13 18 Added part numbers to TagMaster products. 2-13-13 9 Removed wireless wiegand devices
More informationgenesis TECHNICAL MANUAL Two-Door Controller GEN-045
Two-Door Controller GEN-045 Genesis Electronics Australia Pty Ltd www.genesiselectronics.com.au info@genesiselectronics.com.au Australian Owned, Designed and Manufactured Distributed By:- Genesis reserves
More informationQuick Installation Guide MAC1000/MAC1000SR STANDALONE BIOMETRIC CONTROLLER
MAC1000/MAC1000SR STANDALONE BIOMETRIC CONTROLLER Table of contents 1 PRODUCT INTRODUCTION... 2 1.1 NAME AND FUNCTION OF EACH PART... 2 1.2 CABLE COLOR TABLE... 4 1.3 CABLE SELECTION... 6 2 IDENTIFYING
More informationQuick Start Installation Guide
RM-iCLASS Series Quick Start Installation Guide Version C0 Document Part Number UM-208 June 2009 OVERVIEW The RM-iClass Quick Start Installation Guide provides a summary of installation and connection
More informationSecured Series: Hub Plus Kit Single Door Controller Package Installation Manual
Secured Series: Hub Plus Kit Single Door Controller Package Installation Manual This package is designed to simplify the connections to our Secured Series Hub Plus Controller. This will translate into
More informationSERVICE AND INSTALLATION INSTRUCTIONS
MAIN FEATURES INSTRUMENTS, INC. 468 Liberty Drive Wittenberg, WI 54499 U.S.A. SERVICE AND INSTALLATION INSTRUCTIONS EAGLE 2 TEL 715-253-2801 Ver. 04-16-2008 FAX 715-253-2811 www.imcinstruments.com D I
More informationSection A3 PC Programmable Telephone Entry & Access Control For current pricing, please use our Dealer Portal. Date Page Comment
April 2015 Section A3 For current pricing, please use our Dealer Portal. http://doorking.com/dealer-distributor Date Page Comment 4-1-15 All April, 2015 reference guide update. Specifications subject to
More informationLPG STM 94442A User s Manual
1 LPG STM 94442A User s Manual This Manual belongs to: Company: 3 Table of Contents Features....... 4 Hardware Installation...5 Monitor Mounting Dimensions.....7 Monitor Specifications...8 Sender Specifications.....9
More informationThe information in this chapter will enable you to: Understand the product's basic functions & features
C H A P T E R ➀ Chapter Objective Product Description The information in this chapter will enable you to: Understand the product's basic functions & features Introduction The RP240 is designed to operate
More informationINSTRUCTION MANUAL DIGI-LOCK. Keyless Entry System. Installation. Programming. Troubleshooting. BASE Industries
INSTRUCTION MANUAL DIGI-LOCK Keyless Entry System Installation Programming Troubleshooting BASE Industries 45 Pomona Rd. Corona, CA. 9880 Revision F TABLE OF CONTENTS OWNER REGISTRATION CARD INTRODUCTION
More informationMR51e Reader Interface
J4 J TB6 TB5 TB4 TB3 VIN VO TB2 TB J7 2.75 [69.85] 0.2 [5.08] 2.35 [59.69] J3 MR5e Reader Interface Installation and Specifications. General: www.mercury-security.com 2355 MIRA MAR AVE. LONG BEACH, CA
More informationAP-16TB 8 ZONE AUDIO BASE STATION INSTALLATION AND OPERATING INSTRUCTIONS
6955 VALJEAN AVE, VAN NUYS, CA 91406 PH: (818)994-6498 / FAX: (818)994-6458 techsupport@louroe.com / www.louroe.com AP-16TB 8 ZONE AUDIO BASE STATION INSTALLATION AND OPERATING INSTRUCTIONS MODEL AP-16TB
More informationOperation Manual. Thank you for selecting Keyking products. Please read this manual thoroughly before use. Models: TC418/419 Standalone Controller
Operation Manual Thank you for selecting Keyking products. Please read this manual thoroughly before use. Models: TC418/419 Standalone Controller KEYKING GROUP Index Chapter 1: Summay...3 1.1 Outline...3
More informationINSTALLATION TIPS AND MAINTENANCE Manual Number
KD6 Z-SERIES DOME Buy Ultrak Cameras & Parts @ TLS Electronics INSTALLATION TIPS AND MAINTENANCE Manual Number 518854-2960 Ultrak 4465 Coonpath Road Carroll, OH 43112 (800) 443-6680 (740) 756-9222 FAX
More informationCardMaster Installation Manual rev NE 177th Place, Woodinville, WA fax
CardMaster Installation Manual 11.05.30 rev 1 13450 NE 177th Place, Woodinville, WA 98072 www.cardlockvending.com 888-487-5040 fax 425-487-6644 3.0 Critical Do s and Don'ts Do not proceed without reading
More informationQuick Start Guide. GV-Video Server
Quick Start Guide GV-Video Server Thank you for purchasing GV-Video Server. This guide is designed to assist the new user in getting immediate results from the GV-Video Server. For advanced information
More informationA Wholly Owned Subsidiary of Gunnebo AB 5000 Series Audio/Video System Installation & Service Manual
A Wholly Owned Subsidiary of Gunnebo AB 5000 Series Audio/Video System Installation & Service Manual 08-315 (4/28/16) Table of Contents Description...3 System Configuration...3 Cable Considerations...4
More informationCDN502 HIGH DENSITY I/O ADAPTER USER GUIDE
CDN502 HIGH DENSITY I/O ADAPTER USER GUIDE 13050201 (c) Copyright DIP Inc., 1996 DIP Inc. P.O. Box 9550 MORENO VALLEY, CA 92303 714-924-1730 CONTENTS DN502 PRODUCT OVERVIEW 1 DN502 INSTALLATION 1 POWER
More informationInstallation, Operation, and Service Manual SIEMENS HEALTHCARE INTEGRATED ELECTRICAL CABINET
Technical Publications SIEMENS HEALTHCARE INTEGRATED ELECTRICAL CABINET for ARTIS Q / Q.ZEN / ONE ARTIS ZEEGO / ZEEGO.ZEN ARTIS ZEE MULTIPURPOSE SINGLE PLANE IECAX480V125A Main Disconnect Panel Bevco Engineering
More informationMR50 READER INTERFACE
2.75 [69.9] 2.35 [59.7] U1 MR50 READER INTERFAE Installation and Specifications: 1. General: www.mercury-security.com 2355 MIRA MAR AVE. LONG BEAH, A 90815-1755, (562)986-9105 FAX (562) 986-9205 This device
More informationOwner s Manual PC Programmable Multi-Door Access Controller
Owner s Manual 1818 PC Programmable Multi-Door Access Controller DoorKing, Inc. 120 Glasgow Avenue Inglewood, California 90301 U.S.A. Phone: 310-645-0023 Fax: 310-641-1586 www.doorking.com P/N 1818-065
More informationSuprex RF Series CYPRESS. Operations Manual. Suprex Reader Extender - RF Wireless Interface EXP SPX Mhz SPX-5521_MAN_0316
CYPRESS Suprex RF Series Operations Manual Suprex Reader Extender - RF Wireless Interface EXP-2000 SPX-5521 900 Mhz SPX-5521_MAN_0316 Cypress Suprex SPX-5521 Series Overview This manual covers the operation
More informationQuick Start Guide. GV-Video Server
Quick Start Guide GV-Video Server Thank you for purchasing GV-Video Server. This guide is designed to assist new users in getting immediate results from the GV-Video Server. For advanced information on
More informationusing optional EMX 190 expansion modules), and makes access decisions based on its own distributed
Infinity ACX 700 Access Control Unit The Infinity ACX 700 is a programmable, stand-alone access controller that is a basic building block of the Infinity Security Management System. Each ACX 700 controls
More informationAdvanced Visual Solutions Ltd
Advanced Visual Solutions Ltd Unit 2, Eastman Way Hemel Hempstead, Hertfordshire HP2 7DU Telephone : ( 01442 ) 252280 Fax : ( 01442 ) 244578 Email : visionservices@btclick.com : Website : www.avsl.com
More informationInstallation Instructions (KF-2000)
VERSION 2005. 10 Installation Instructions (KF-2000) Keico Hightech, Inc. Installation Instructions KF-2000 Keico Hightech Ace Twin Tower I 12 th FL 212-1, Guro-Dong, Guro-Gu Phone +82-2-853-9000 Fax +82-2-830-7809
More informationCDN503 HIGH DENSITY I/O ADAPTER USER GUIDE
CDN503 HIGH DENSITY I/O ADAPTER USER GUIDE 13050301 (c) Copyright DIP Inc., 1996 DIP Inc. P.O. Box 9550 MORENO VALLEY, CA 92303 714-924-1730 CONTENTS DN503 PRODUCT OVERVIEW 1 DN503 INSTALLATION 1 POWER
More informationQuick Start Installation Guide
istar Pro Quick Start Installation Guide Version B0 Part Number UM-069 January 2005 OVERVIEW This guide defines all of the commonly used connection methods to the istar Pro. It outlines how to wire readers
More informationEPD. Installation/Owner s Manual. Model 1802 & 1802EPD Telephone Entry System. Surface Mount Flush Mount. UL Listed
Installation/Owner s Manual Use this manual for circuit board 86- Revision L or higher. Model 8 & 8EPD Telephone Entry System 8-65-D--4 Control a main entry point plus an additional entry point. 8. 3 ATING
More informationWRI400 WIRELESS READER INTERFACE
WRI400 WIRELESS READER INTERFACE Technical Services Training for the WRI400 Launched April 2011 March 12 Technical Services Engineering Support 1 Training Overview WRI400 Description Information Installation
More informationModel SAP612 Source Assign Panel User Manual
Model SAP612 Source Assign Panel User Manual 9350-6872-00 Rev E April 2007 PROPRIETARY NOTICE The product information and design disclosed herein were originated by and are the property of Telex Communications,
More informationSPX-7400_SPX-7410_MAN_161028
Suprex Fiber Optic SPX-7400 & SPX-7410 Suprex Reader-Extender Data Sheet SPX-7400 Series EXP-2000 SPX-7400_SPX-7410_MAN_161028 1 Cypress Suprex SPX-7400 & SPX-7410 Overview The Suprex Fiber Optic SPX-7400
More informationTek-ENTRY Telephone Entry System. Specification Sheets Submittal Package. as of 10/4/2010
Tek-ENTRY Telephone Entry System s Submittal Package as of 10/4/2010 Phone: (828) 524-9967 Toll-Free: (800) 327-8466 Tech Support: Option 2 Sales: Option 3 277 Industrial Park Road Franklin, NC 28734 tektone@tektone.net
More informationSECURA KEY CARD ACCESS CONFIGURATION GUIDE Multi-Reader Systems with NOVA.16 (SK-MRCP) 16-Door Panel
SECURA KEY CARD ACCESS CONFIGURATION GUIDE Multi-Reader Systems with (SK-MRCP) -Door Panel WITH RS- GATEWAY CONNECTED DIRECTLY TO A PC RS- GATEWAY POWER: EIGHT (8) SMART READERS EVENLY SPACED UP TO 000
More informationAlphaStatus Room Status System Installation and Use Instructions for the RSS400 Series Room Stations and Optional Master Station(s)
AlphaStatus Room Status System Installation and Use Instructions for the RSS400 Series Room Stations and Optional Master Station(s) APPLICATION The AlphaStatus system allows one or more RSS402, RSS403,
More informationInstalling Sentor. Hardware Installation
Remote base site monitoring and control Installing Sentor Hardware Installation Copyright 2000 Sentor Monitoring Systems Pty Ltd Contents: 1 Introduction... 1 2 Sentor GUI... 2 3 ST3000 Controller... 3
More informationINNOMETRIKS INC. Rhino Quick Start Guide
INNOMETRIKS INC Rhino Quick Start Guide Rhino Quick Start Guide Innometriks Inc Fallbrook, Ca. 92028 Phone 760-207-6908 Sales: Sales@innometriksinc.com General Information: Info@innometriksinc.com Customer
More informationPIB300 and PIB301 User Guide. Installation and operation instructions for Panel Interface Board
*P516-097* P516-097 PIB300 and PIB301 User Guide Installation and operation instructions for Panel Interface Board Para el idioma español, navegue hacia www.schlage.com/support Pour la portion française,
More informationMR52 READER INTERFACE
IN IN2 IN3 IN4 INPUTS IN5 IN6 IN7 IN8 C www.mercury-security.com 2355 MIRA MAR AVE. LONG BEACH, CA 9085-755, (562)986-905 FAX (562) 986-9205 MR52 READER INTERFACE Installation and Specifications: This
More informationAndover ContinuumTM Infinet II
Andover ContinuumTM Infinet II The i80 Series controllers are designed for control of Air Handling Units, Roof Top Units, and other mechanical plant equipment. Features 0 Choose the i80 model with the
More informationU-FLASH Setup Guide U-FLASH.
U-FLASH Setup Guide Thank you for purchasing the U-FLASH. This guide will assist you in the setup of the system. You can call for FREE technical support to get help anytime at 757-258-0910. Please note,
More informationUSBCNC USB Disk Key reader for CNC Controls Machine Mount instructions
USBCNC USB Disk Key reader for CNC Controls Machine Mount instructions 2008-2015 Calmotion LLC, All rights reserved Calmotion LLC 21720 Marilla St. Chatsworth, CA 91311 www.calmotion.com Introduction This
More informationGreyfield Audio/Video Frequently Asked Questions
Greyfield Audio/Video Frequently Asked Questions Audio Q. I have a system with multiple 5501 series audio consoles. Why do the consoles seem to have different outgoing volumes? A. Check the firmware revision
More informationMRDT Display Terminal
www.mercury-security.com 2355 MIRA MAR AVE. LONG BEACH, CA 90815-1755, (562)986-9105 FAX (562) 986-9205 MRDT Display Terminal Installation and Specifications: This device complies with part 15 of the FCC
More informationINSTALLATION MANUAL. ST-BTWD650IR2812 B or W Weatherproof Day/Night Infrared Color Camera
INSTALLATION MANUAL ST-BTWD650IR2812 B or W Weatherproof Day/Night Infrared Color Camera PACKAGE CONTENTS This package contains: One ST-BTWD650IR2812 camera with Black or White housing One extension tube
More informationAD-1 POWER SUPPLY. AD-1 listed AC ADAPTER. Supplies 12 Vdc to both AP-1TB and remote speaker/microphone.
6955 VALJEAN AVE, VAN NUYS, CA 91406 PH: (818)994-6498 / FAX: (818)994-6458 techsupport@louroe.com / www.louroe.com AP-1TB SINGLE ZONE TWO-WAY AUDIO BASE STATION INSTALLATION AND OPERATING INSTRUCTIONS
More informationicam7000s SERIES HARDWARE GUIDE Packing List CONTACTLESS CARD READER RECESS MOUNT (Optional) ISO/ANSI COMPLIANT EASY INSTALLATION What s in the Box
icam7000s SERIES HARDWARE GUIDE ADVANCED MULTIFACTOR BIOMETRIC IRIS READER VERSION 1.0 icam7000s-t (Titanium Color) icam7000s-b (Black Color) DUAL IRIS ISO/ANSI COMPLIANT FACE CAMERA EASY INSTALLATION
More informationSystem Galaxy Hardware Manual
System Galaxy Hardware Manual Version 2.4 June 19, 2004 System Galaxy Hardware Manual 1 Information in this document is subject to change without notice. No part of this document may be reproduced, copied,
More informationEPD. Installation/Owner s Manual. Model 1802 & 1802EPD Telephone Entry System. Surface Mount Flush Mount. UL Listed
Installation/Owner s Manual Use this manual for circuit board 86- Revision O or higher. Model 8 & 8EPD Telephone Entry System 8-65-G-3-5 Control a main entry point plus an additional entry point. 8. 3
More informationSK-ACPE User/Installation Manual
User/Installation Manual COPYRIGHT 0 TABLE OF CONTENTS. INTRODUCTION... Introduction to Card ID Numbers and Facility Codes Setting the Facility Codes. INSTALLATION... Physical Installation Wiring... Power
More informationKT-300 DOOR CONTROLLER INSTALLATION MANUAL DN KANTECH SYSTEMS INC.
KT-300 DOOR CONTROLLER INSTALLATION MANUAL NOVEMBER 1999 KT-300 - ENGLISH INSTALLATION MANUAL - INTRODUCTION Part of the DSC group, Kantech Systems Inc. embraces the group's corporate philosophy of providing
More information