Original operating instructions Safety relay with relay outputs with and without delay G1502S / / 2016

Size: px
Start display at page:

Download "Original operating instructions Safety relay with relay outputs with and without delay G1502S / / 2016"

Transcription

1 Original operating instructions Safety relay with relay outputs with and without delay UK G50S / 00 0 / 06

2 Contents Preliminary note...4. Symbols used...4 Safety instructions Items supplied Functions and features Requirements for the hardware configuration Product-independent requirements Product-dependent requirements Structure and operating principle Indicators and connections Block diagram Installation Electrical connection Supply voltage Feedback contacts / monitored or automatic start Output circuit... 8 Connection - Function - diagnosis Safety relay for fail-safe sensors/switches with PNP outputs Connection Function diagnosis Safety relay for clocked fail-safe sensors Connection Function diagnosis Two-hand control using electronic sensors/switches Connection Function diagnosis Two-hand control using mechanical switches with simultaneity monitoring Connection Function diagnosis...39

3 8.5 Safety relay for e-stop, for -channel fail-safe sensors/switches with contact output or for mechanical switches Connection Function diagnosis Programming Programming of the switch-off delay Scale drawing...48 Technical data...48uk Tests/approvals Terms and abbreviations...5 3

4 Preliminary note The instructions are part of the unit. They are intended for authorised persons according to the EMC, Low Voltage Directive and Machinery directives and safety regulations. The instructions contain information about the correct handling of the product. Read the instructions before use to familiarise yourself with operating conditions, installation and operation. Adhere to the safety instructions.. Symbols used Instruction > Reaction, result Cross-reference LED off LED on LED flashes LED flashes quickly Important note Non-compliance can result in malfunction or interference. Information Supplementary note. 4

5 Safety instructions Follow the operating instructions. Improper use may result in malfunctions of the unit. This can lead to personal injury and/or damage to property during operation of the machine. For this reason note all remarks on installation and handling given in these instructions. Also adhere to the safety instructions for the operation of the whole installation. In case of non-observance of notes or standards, specially when tampering with and/or modifying the unit, any liability and warranty is excluded. The unit must be installed, connected and put into operation by a qualified electrician trained in safety technology. The applicable technical standards for the corresponding application must be complied with. For installation the requirements according to EN 6004 must be observed. In case of malfunction of the unit please contact the manufacturer. Tampering with the unit is not allowed. Disconnect the unit externally before handling it. Also disconnect any independently supplied relay load circuits. After setup the system has to be subjected to a complete function check. Use the unit only in specified environmental conditions ( Technical data). In case of special operating conditions please contact the manufacturer. Use only as described below ( 4). UK 5

6 3 Items supplied safety relay G50S copy of the operating instructions safety relay, reference If one of the above-mentioned components is missing or damaged, please contact one of the ifm branch offices. 4 Functions and features The safety relay is a redundant system and suited for use as: Safety relay for fail-safe sensors/switches with PNP outputs (e.g. GM70S, chapter 8.). Safety relay for clocked fail-safe sensors (e.g. GM504S, chapter 8.). Relay for two-hand control to EN 574, type IIIC, with electronic sensors/ switches ( chapter 8.3). Relay for two-hand control to EN 574, type IIIC with mechanical switches / safety relay for mechanical switches or -channel fail-safe sensors/switches (e.g. ESPE to EN 6496-) with contact output with simultaneity monitoring ( chapter 8.4). Safety relay for e-stop, for two-channel fail-safe sensors/switches (e.g. ESPE to EN 6496-) with contact output without simultaneity monitoring (indefinite simultaneity) or for mechanical switches ( chapter 8.5). ifm electronic gmbh assumes no liability for the use of units made by external manufacturers. The safe state is when the output contacts 3-4, 3-4, 33-34, 43-44, or are open and the output contact 5-5 is closed. 4. Requirements for the hardware configuration The following requirements must be met when using the G50S safety relay: 4.. Product-independent requirements It must be ensured that the safety requirements of the respective application correspond to the requirements stated in these instructions. The specified technical data indicated in these instructions must be complied with. The principle of normally closed operation must be applied to all external safety circuits connected to the system. 6

7 The safety relays type G50S in operation have to be subjected to a self-test (switching off) within a period of maximum month. The self-test can be carried out by switching the supply voltage off and on or by a safety request. 4.. Product-dependent requirements In case of faults within the safety relay which result in the defined safe state, the safety relay must be replaced. Any faulty unit should be returned to the manufacturer. UK 7

8 5 Structure and operating principle 5. Indicators and connections A3 S33 S34 S43 S44 C 3 4 A Y4 Y5 Y6 Y7 C 3 4 A L- Y Y Power C T C C C A Supply voltage (L-, ), function terminals (Y, Y) A A3 Y4, Y5, Y6, Y7: Operating mode selection, auxiliary output S33, S34, S43, S44: Connection for safety inputs / output K LED yellow: Triggering the relay outputs channel K LED yellow: Triggering the relay outputs channel E E Power T C LED yellow: Input signal channel or TE (for clocked sensor) LED yellow: Input signal channel or A (for clocked sensor) LED green: Voltage supply LED red: /start-up LED red: / LED yellow: Triggering the relay output with switch-off delay 3, 4: Connection of relay output without delay, x normally open (closed when enabled) 8

9 C C3 C4 C5 C6 3, 4: Connection of relay output without delay, x normally open (closed when enabled) 33, 34: Connection of relay output without delay, x normally open (closed when enabled) 43, 44: Connection of signal output without delay, x normally open (closed when enabled) 5, 5: Connection of signal output without delay, x normally closed (open when enabled) 67, 68: Connection of relay output with switch-off delay, x normally open (closed when enabled) 77, 78: Connection of relay output with switch-off delay, x normally open (closed when enabled) UK 5. Block diagram C C C3 C4 C4 C5 C6 L- Y4 Y S34 S43 Y5 Y Y6 S33 S44 Y INPUT CIRCUIT OUTPUT CIRCUIT MCU (CONTROLLER) K3 MCU (CONTROLLER) K

10 6 Installation Mount the unit on a DIN rail in a housing protected against dust and humidity (min. IP54 - degree of soiling ). 7 Electrical connection Use 60/75 C copper conductors only. 7. Supply voltage The external supply unit must have a safe separation. In case of a fault the voltage can exceed the value of 60 V DC for a maximum of 00 ms, but must not exceed the value of 0 V DC. Connect supply voltage Manual reset RESET For safety reasons the unit can only be restarted by separation from the supply voltage in case of a fault. It is thus recommended to install a RESET switch in series with the circuit. After power on or a RESET the unit carries out self diagnostic functions. After this self diagnosis the unit is ready for operation. 0

11 7. Feedback contacts / monitored or automatic start Automatic start A L- Y Y Automatic activation without monitoring. Monitoring of the feedback contacts (normally closed) for automatic start The circuit is enabled when the feedback contacts are closed. Consider the current flowing through the feedback contacts ( Technical data). UK : feedback contact Monitored start Activate the relay outputs: Press and release the start button (> 50 ms). This function is not active when used as two-hand control. : start button Monitoring of the feedback contacts (normally closed) for monitored start Activate the relay outputs: Feedback contacts are closed Press and release the start button (> 50 ms). This function is not active when used as two-hand control. Consider the current flowing through the feedback contacts ( Technical data). : feedback contact : start button

12 7.3 Output circuit Last anschließen C 3 4 3,6 A Connect the load to be controlled to the relay outputs on C (3, 4), C (3, 4), C3 (33, 34), C5 (67, 68) or C6 (77, 78). Adhere to max. and min. contact rating ( Technical data). C 3 4 3,6 A C K3 3,6 A C K4 3,6 A C K5 3,6 A C The relay outputs C4 (43, 44 and 5, 5) provide a non safety-related signal. The signal corresponds to that triggering the relays at the outputs C (3, 4); C (3, 4) and C3 (33, 34). The total current, i.e. the max. current load of all output circuits of the safety relay (C-C6), must not exceed A.

13 A Y4 Y5 Y6 Y7 The signal output Y7 provides a non-safety related signal for communication to a plc. The signal corresponds to that triggering the relays at the outputs C5 (67, 68) and C6 (77,78). The output data is compatible with the input data of the current-sinking inputs of type,, 3 to EN 63-. : Input : SPS 8 Connection - Function - diagnosis The safety relay can be connected or used in different ways:. Safety relay for fail-safe sensors/switches with PNP outputs (e.g.gm70s).. Safety relay for clocked fail-safe sensors (e.g. GM504S). 3. Relay for two-hand control to EN 574 with electronic sensors. 4. Relay for two-hand control to EN 574 with mechanical switches / safety relay for mechanical switches or -channel fail-safe sensors/switches (e.g. ESPE to EN 6496-) with contact output with simultaneity monitoring. 5. Safety relay for e-stop, for two-channel fail-safe sensors/switches (e.g. ESPE to EN 6496-) with contact output without simultaneity monitoring (indefinite simultaneity) or for mechanical switches. UK 3

14 8. Safety relay for fail-safe sensors/switches with PNP outputs Example of fail-safe sensors/switches: Fail-safe inductive sensor GM70S Light barrier Light curtain (ESPE to EN 6496-) Laser scanner 8.. Connection Fail-safe sensor/switch with a current consumption of 50 ma: G50S : Fail-safe sensor/switch Fail-safe sensor/switch with a current consumption of > 50 ma: G50S : Fail-safe sensor/switch 4

15 8.. Function Input circuit Output status LED display Y td = s T UK Y T td = s * T Stop flashing: Activate inputs in correct time sequence ( fig. above) * During the switch-off delay (td > 0 s) 5

16 Input circuit Output status LED display Y td = s Y T td = s * T T T * During the switch-off delay (td > 0 s) 6

17 Input circuit Output status LED display Y td = s * UK Y T td = s * T T T * During the switch-off delay (td > 0 s) 7

18 8..3 diagnosis In case of a fault switch the safety relay off and on again! LED display Cause of the fault Troubleshooting T No voltage supply Overvoltage Connection A/A3 or A/A reversed Check power supply T Wire break Feedback contacts open Switch the safety relay off and on again T When voltage is applied: Feedback contacts open Check output circuit Check feedback contacts Exchange external contactor T Wiring fault Short circuit Inputs S34 and S43 when voltage is applied Switch the fail-safe sensor/ switch off and on again Short circuit S33/S43 T T Short circuit S33/S43 8

19 LED display Cause of the fault Troubleshooting Overvoltage Undervoltage Check power supply T Overvoltage Undervoltage Check power supply T UK Undervoltage Check power supply T T T T Short circuits T Input S43 active more than 0.5 s after input S34 ( 8..) Feedback contact error Short circuit S34/S44 Switch the fail-safe sensor/ switch off and on again 9

20 LED display Cause of the fault Troubleshooting T The rotary switch for programming the switch-off delay was changed y programming Program it again ( 9.) 0

21 8. Safety relay for clocked fail-safe sensors Example of fail-safe sensors/switches: Fail-safe inductive sensor GM504S Up to 0 clocked fail-safe sensors can be connected to one safety relay. 8.. Connection Connection of one fail-safe sensor/switch: G50S UK : Fail-safe sensor/switch Connection of fail-safe sensors/switches: G50S : Fail-safe sensor/switch : Fail-safe sensor/switch

22 The use of the safety splitter box 569 is recommended: G50S : Fail-safe sensor/switch : Fail-safe sensor/switch 3: 569 4: e.g. EVC04 5: e.g. EVC00 wh = white bk = black bn = brown bu = blue Connection of 3 to 0 fail-safe sensors/switches: G50S : Fail-safe sensor/switch : Fail-safe sensor/switch 3: Fail-safe sensor/switch 3

23 The use of the safety splitter box 569 is recommended: G50S UK : Fail-safe sensor/switch : Fail-safe sensor/switch 3: Fail-safe sensor/switch 3 4: 569 5: e.g. EVC04 6: e.g. EVC00 wh = white bk = black bn = brown bu = blue 3

24 8.. Function Input circuit Output status LED display Y T td = s Y T td = s * T : First or last fail-safe sensor/switch of a row of sensors/switches : td = max. 6 ms * During the switch-off delay (td > 0 s) 4

25 8..3 diagnosis In case of a fault switch the safety relay off and on again! LED display Cause of the fault Troubleshooting T T No voltage supply Overvoltage Connection A/A reversed Wire break Feedback contacts open Time-dependent contacts Check power supply Switch the safety relay off and on again UK T T When voltage is applied: Feedback contacts open Short circuit Connection A/A3 or A/A3 exchanged Short circuit S43/ or S44/L- Check output circuit Check feedback contacts Exchange external contactor T Short-circuit S34/S44 or S33/ S43 T Short circuit S34/ T 5

26 LED display Cause of the fault Troubleshooting Short circuit S43/ or S34/S44 T T Missing clock Wiring fault Connection A/A3 reversed Short circuit S43/L- Overvoltage Undervoltage Check power supply T Overvoltage Undervoltage Check power supply T Undervoltage Check power supply T T 6

27 LED display Cause of the fault Troubleshooting Short circuits T T UK T The rotary switch for programming the switch-off delay was changed y programming Program it again ( 9.) 7

28 8.3 Relay for two-hand control using electronic sensors/switches Example of electronic sensors/switches: Capacitive sensors For product selection see This wiring meets the requirements type IIIB to EN 574. Use up to type IIIC is possible using corresponding sensors/switches with two independent switching elements, internal plausibility check and protected or screened wires Connection Connection of two -wire DC: G50S : Electronic fail-safe sensor : Electronic fail-safe sensor 8

29 8.3. Function Input circuit Output status LED display Y td = s T UK Y T td = s * T : Electronic fail-safe sensor : Electronic fail-safe sensor * During the switch-off delay (td > 0 s) 9

30 Input circuit Output status LED display Y T td = s * T Y T td = s * T : Electronic fail-safe sensor : Electronic fail-safe sensor * During the switch-off delay (td > 0 s) 30

31 Input circuit Output status LED display Y T td = s * UK T : Electronic fail-safe sensor : Electronic fail-safe sensor * During the switch-off delay (td > 0 s) 3

32 8.3.3 diagnosis In case of a fault switch the safety relay off and on again! LED display Cause of the fault Troubleshooting T No voltage supply Overvoltage Connection A/A3 or A/A reversed Check power supply T Wire break Feedback contacts open Time-dependent contacts Switch the safety relay off and on again T When voltage is applied: Feedback contacts open Check output circuit Check feedback contacts Exchange external contactor T Wiring fault Missing link Y4/Y5 Short circuit Inputs S34 and S43 activated when voltage is applied Connections A3/A reversed Deactivate inputs and RESET or voltage failure T Missing link Y4/Y5 T Overvoltage Undervoltage Check power supply T 3

33 LED display Cause of the fault Troubleshooting Overvoltage Undervoltage Check power supply T Undervoltage Check power supply T UK T T Short circuits T T T Inputs S34 and S43 not activated within 0.5 s ( 8.3.) Feedback contact error Short circuit S34/S44 The rotary switch for programming the switch-off delay was changed y programming Deactivate inputs and activate them again Program it again ( 9.) 33

34 8.4 Relay for two-hand control using mechanical switches with simultaneity monitoring Two-hand control with mechanical switches / safety relay for mechanical switches or -channel fail-safe sensors/switches with contact output with simultaneity monitoring. The contacts of the mechanical switches must allow a minimum current of 6 ma Connection Connection of two mechanical fail-safe switches This wiring (with only one normally open contact per sensor/switch) meets the requirements of type IIIB to EN 574. Use up to type IIIC is possible using corresponding sensors/switches approved to EN annex K and protected or screened wires. G50S : Mechanical fail-safe switch : Mechanical fail-safe switch 34

35 Connection of mechanical switches according to type IIIC to EN 574 G50S UK : Mechanical switch (no positively driven contacts) : Mechanical switch (no positively driven contacts) Connection of a -channel fail-safe sensor/switch e.g. "electro-sensitive protective equipment" (ESPE) to EN G50S : Contact of the ESPE : Contact of the ESPE 35

36 8.4. Function Input circuit Output status LED display Y T td = s Y T td = s * T : N.O. contact activated * During the switch-off delay (td > 0 s) 36

37 Input circuit Output status LED display Y T td = s * UK T Y T td = s * T : Electronic fail-safe sensor : Electronic fail-safe sensor * During the switch-off delay (td > 0 s) 37

38 Input circuit Output status LED display Y T td = s * T : Electronic fail-safe sensor : Electronic fail-safe sensor * During the switch-off delay (td > 0 s) : N.O. contact activated 38

39 8.4.3 diagnosis In case of a fault switch the safety relay off and on again! LED display Cause of the fault Troubleshooting T T No voltage supply Overvoltage Connection A/A3 or A/A reversed Wire break Feedback contacts open Time-dependent contacts Check power supply Switch the safety relay off and on again UK T T When voltage is applied: Feedback contacts open Wiring fault Missing link Y4/Y5 Short circuit Contacts closed when voltage is applied Connection A/A3 reversed Check output circuit Check feedback contacts Exchange external contactor Open contacts and RESET or voltage failure T Overvoltage Undervoltage Check power supply T Overvoltage Undervoltage Check power supply T 39

40 LED display Cause of the fault Troubleshooting Undervoltage Check power supply T T T Short circuits T T T Inputs S34 and S43 not activated within 0.5 s ( 8.4.) Feedback contact error Short circuit S34/S44 The rotary switch for programming the switch-off delay was changed y programming Deactivate inputs and activate them again Program it again ( 9.) 40

41 8.5 Safety relay for e-stop, for -channel fail-safe sensors/ switches with contact output or for mechanical switches In this operating mode the simultaneity of the contacts is not monitored. The -channel fail-safe sensors/switches are for example "electro-sensitive protective equipment" (ESPE) to EN The contacts of the sensors/switches must allow a minimum current of 6 ma Connection Connection e-stop / -channel fail-safe sensors/switches: UK G50S : Fail-safe sensor/switch Connection of two mechanical switches: G50S : Mechanical switch : Mechanical switch 4

42 8.5. Function Input circuit Output status LED display Y T td = s Y T td = s * T : Fail-safe sensor/switch : Fail-safe sensor/switch 3: Order and time difference insignificant (indefinite simultaneity) * During the switch-off delay (td > 0 s) : N.O. contact activated 4

43 Input circuit Output status LED display Y T td = s * UK T Y T td = s * T : Fail-safe sensor/switch : Fail-safe sensor/switch * During the switch-off delay (td > 0 s) : N.O. contact activated 43

44 8.5.3 diagnosis In case of a fault switch the safety relay off and on again! LED display Cause of the fault Troubleshooting No voltage supply Overvoltage Check power supply T Short circuit Wire break T Short circuit Wire break T Short circuit Wire break T Feedback contacts open Wire break T T T When voltage is applied: Feedback contacts open Wiring fault Missing link Y4/Y5 Short circuit Check output circuit Check feedback contacts Exchange external contactor 44

45 LED display Cause of the fault Troubleshooting Connection A/A3 reversed T Missing link Y4/Y5 T UK Overvoltage Undervoltage Check power supply T Overvoltage Undervoltage Check power supply T Undervoltage Check power supply T T 45

46 LED display Cause of the fault Troubleshooting Short circuits T T T The rotary switch for programming the switch-off delay was changed y programming Program it again ( 9.) 46

47 9 Programming In all described operating modes ( ) a switch-off delay for the relay outputs on terminals C5 and C6 can be set. 9. Programming of the switch-off delay Set the rotary switch to position F. Switch the unit off and on again. > > Yellow LED [] flashes quickly: The unit is in the programming mode. Set the rotary switch to the desired position without delay: Pos. F A B C D E [s] UK : Programming mode > > After.5 seconds the yellow LED [] is permanently lit > > Programming is completed, the delay is stored permanently. When the unit is switched on again, it is ready for operation with the new delay. Do not change the position of the rotary switch any more. Protection against defeating: In case of subsequent changes the unit goes into the safe state and the LEDs [T] and [] indicate an error ( fault diagnosis). Program it again. On delivery the outputs are set without delay, i.e. the rotary switch is at position E. 47

48 0 Scale drawing ,5 LED : Rotary switch for switch-off delay : Screw terminal (supplied) Technical data G50S Safety relay with relay outputs Terminal block Phoenix Contact MSTBO Meets the requirements of: EN ISO 3849-: 008+AC009, category 4 PL e, SIL 3 (IEC 6508) Electrical design Output function Operating voltage Relay 3 safety-related NO contacts (floating) without delay; non safety-related signal outputs without delay ( x NO, x NC, floating contacts) safety-related NO contacts (floating) with switch-off delay signal output (positive switching) with delay 4 V DC (9...30) incl. 5 % residual ripple 48

49 Contact rating Minimum load current of the feedback contacts Short-circuit protection / overload protection Current consumption Function display Power-on delay time 6 A, 50 V AC / 4 V DC ( 6 ma) max. total current: A 0 ma The contacts are to be protected by means of fuses with a nominal current of < 3.6 A < 500 ma voltage (green), error ( x red), output status (3 x yellow), input ( x yellow) < 6 s Duration of switch-off test pulses 500 µs Response time [ms] acc. to input circuit chapter Ambient temperature Release Safety requirement C Protection rating IP 0 Housing materials Input characteristics (S34, S43) Output characteristics Mission Time (TM) PA "": > V, 6 ma "0": < 5 V, < 500 µa S33 push-pull short-circuit proof "0": I sink ~ 30 ma "": I source 50 ma, U > 8 V S44 "0": I R 300 µa "": I source 50 ma, U > 8 V Y7 "0": I R 300 µa "": I source 30 ma, 5 5 ma h PFH D 5,86 x 0-9 / h *) B0 D *) UK 49

50 Comments Additional comments concerning the culus approval (UL 508): Maximum ambient temperature 55 C (in the control cabinet) The safety functions were not assessed by UL. The approval has been made according to UL 508 for general applications. Use 60/75 C copper conductors only. For use in pollution degree environment Same polarity (phase) referred to the output contacts *) with h op = 4 h, d op = 365 days, t cycle = 3600 s Tests/approvals The G50S safety relay was tested and certified by TÜV-Nord. The safety relay was developed and tested in accordance with, for example, the following directives and standards: 006/4/EC Machinery Directive 004/08/EC EMC Directive 04/30/EU EMC Directive (effective from 0 April 06) EN 5078 (997) Electronic equipment for use in power installations EN ISO 3849-: 008+AC009 Safety of machinery, safety-related parts of control systems DIN EN 6004-:006 (where applicable) Electrical equipment of machines EN (03) Non-contact protective equipment - General requirements and tests EN 574:996+A: 008 Safety of machinery - Two-hand control devices - Functional aspects - Principles for design IEC 6508: 00 Functional safety of electrical/electronic/programmable electronic safety-related systems EN 606: 005+A: 03 Safety of machinery - Functional safety of safetyrelated electrical, electronic and programmable electronic control systems UL

51 3 Terms and abbreviations ESPE Electro-Sensitive Protective Equipment. Cat. Category Category Classification of the safety-related parts of a controller as regards their resistance to failures. CCF Common Cause Failure Common cause failure DC Diagnostic Coverage Diagnostic coverage. UK MTTF Mean Time to Failure Mean time to failure. MTTF d Mean Time To Dangerous Failure Mean time to dangerous failure. OSSD Output Signal Switching Device Output signal switch element, static safety-related output. PFH (PFH D ) Probability of (dangerous) Failure per Hour Probability of a (dangerous) failure per hour. PL Performance Level PL to EN ISO SIL Safety Integrity Level SIL -4 to IEC 6508 PLC Programmable Logic Controller Technical data and further information at 5

Original operating instructions Safety relay with relay outputs G1501S / / 2016

Original operating instructions Safety relay with relay outputs G1501S / / 2016 Original operating instructions Safety relay with relay outputs G50S UK 8023637 / 00 02 / 206 Contents Preliminary note...4. Symbols used...4 2 Safety instructions...5 3 Items supplied...6 4 Functions

More information

Original operating instructions Fail-safe inductive sensor GI711S / / 2010

Original operating instructions Fail-safe inductive sensor GI711S / / 2010 Original operating instructions Fail-safe inductive sensor GI7S 704583 / 0 06 / 200 Contents Preliminary note 3. Explanation of symbols 3 2 Safety instructions 4 2. Safety-related requirements regarding

More information

Original operating instructions Fail-safe inductive sensor GF711S / / 2013

Original operating instructions Fail-safe inductive sensor GF711S / / 2013 Original operating instructions Fail-safe inductive sensor GF7S 8528 / 5 / 23 Contents Preliminary note...3. Explanation of symbols...3 2 Safety instructions...4 2. Safety-related requirements regarding

More information

Operating instructions. Switching amplifier DN0210 DN / / 2015

Operating instructions. Switching amplifier DN0210 DN / / 2015 Operating instructions Switching amplifier DN0210 DN0220 UK 80011079 / 00 01 / 2015 Contents 1 Preliminary note...4 1.1 Symbols used...4 1.2 Warning signs used...4 2 Safety instructions...5 2.1 General...5

More information

Operating instructions. Speed monitor D / / 2014

Operating instructions. Speed monitor D / / 2014 Operating instructions Speed monitor D200 80005257 / 00 05 / 2014 Contents 1 Preliminary note...4 1.1 Symbols used...4 1.2 Warning signs used...4 2 Safety instructions...5 2.1 General...5 2.2 Target group...5

More information

Operating instructions. Standstill monitor A / / 2011

Operating instructions. Standstill monitor A / / 2011 Operating instructions Standstill monitor A300 UK 1 2 3 4 5 6 7 8 7390337 / 01 02 / 2011 1 2 3 4 5 6 7 8 switchpoint min max pulse/min power Made in Germany ifm electronic gmbh D 45127 Essen func. I II

More information

Original operating instructions Fail-safe inductive sensor GI712S

Original operating instructions Fail-safe inductive sensor GI712S Original operating instructions Fail-safe inductive sensor GI712S 80236527 / 00 12 / 2016 Contents 1 Preliminary note...3 1.1 Symbols used...3 1.2 Warning signs used...3 2 Safety instructions...4 2.1 Safety-related

More information

Original operating instructions Fail-safe inductive sensor GG711S

Original operating instructions Fail-safe inductive sensor GG711S Original operating instructions Fail-safe inductive sensor GG7S 8236522 / 2 / 26 Contents Preliminary note...3. Symbols used...3.2 Warning signs used...3 2 Safety instructions...4 2. Safety-related requirements

More information

System manual AS-i safety monitor AC041S /00 05/2013

System manual AS-i safety monitor AC041S /00 05/2013 System manual AS-i safety monitor AC041S UK 7390926/00 05/2013 Contents 1 Preliminary note...4 1.1 Symbols used...4 2 Safety instructions...5 3 Items supplied...6 4 Functions and features...6 5 Structure

More information

Original operating instructions Photoelectric safety sensors (safety light grid) with active / passive system OY90xS

Original operating instructions Photoelectric safety sensors (safety light grid) with active / passive system OY90xS Original operating instructions Photoelectric safety sensors (safety light grid) with active / passive system OY90xS UK 704818 / 01 10 / 2016 Contents 1 Preliminary note...4 1.1 Symbols used...4 1.2 Warning

More information

Operating instructions Evaluation system for flow sensors VS / / 2013

Operating instructions Evaluation system for flow sensors VS / / 2013 Operating instructions Evaluation system for flow sensors VS3000 7097 / 0 07 / 203 Contents Preliminary note...2 2 Safety instructions...3 3 Function and features... Mounting.... Mounting of the sensors...

More information

Installation instructions Diagnostic electronics for vibration sensors VSE / / 2007

Installation instructions Diagnostic electronics for vibration sensors VSE / / 2007 Installation instructions Diagnostic electronics for vibration sensors UK VSE00 70406 / 00 07 / 2007 Contents Safety instructions 3 Function and features 4 Mounting 4 Mounting of the sensors 5 Electrical

More information

Operating instructions Optical distance sensor. O5D15x / / 2014

Operating instructions Optical distance sensor. O5D15x / / 2014 Operating instructions Optical distance sensor O5D15x 706307 / 01 08 / 2014 Contents 1 Preliminary note...3 1.1 Symbols used...3 2 Safety instructions...3 3 Functions and features...4 3.1 Applications...4

More information

Operating instructions Optical distance sensor. OID25x / / 2014

Operating instructions Optical distance sensor. OID25x / / 2014 Operating instructions Optical distance sensor OID5x 70608 / 01 08 / 01 Contents 1 Preliminary note... 1.1 Symbols used... Safety instructions... Functions and features....1 Applications... Installation...5.1

More information

User's Manual. english

User's Manual. english BES M12EN-PFC40F-S04G-D11 BES M18EN-PFC80F-S04G-D11 BES M18MN-PFC50B-S04G-D11 BES M30EN-PFC15F-S04G-D11 BES M30MN-PFC10B-S04G-D11 Inductive Safety Sensors User's Manual english www.balluff.com Original

More information

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016 Operating instructions AS-i SmartLine module AC3200 AC3201 80237876/00 06/2016 Contents 1 Preliminary note...3 1.1 Symbols used...3 1.2 Warnings used...3 2 Safety instructions...3 2.1 General...3 2.2 Target

More information

Operating instructions Optical distance sensor. OID25x / / 2015

Operating instructions Optical distance sensor. OID25x / / 2015 Operating instructions Optical distance sensor OID25x 80228366 / 00 03 / 2015 Contents 1 Preliminary note...3 1.1 Symbols used...3 2 Safety instructions...3 3 Functions and features...4 3.1 Applications...4

More information

Operating instructions. Monitor FD / / 2013

Operating instructions. Monitor FD / / 2013 Operating instructions Monitor FD-1 UK 7390956 / 00 01 / 2013 Contents 1 Preliminary note...4 1.1 Symbols used...4 1.2 Warning signs used...4 2 Safety instructions...5 2.1 General...5 2.2 Target group...5

More information

Control unit SG-EFS 104/4L. EN Operating instructions. Innovative by tradition. Version SG-EFS 104/4L AC/DC 24 V

Control unit SG-EFS 104/4L. EN Operating instructions. Innovative by tradition. Version SG-EFS 104/4L AC/DC 24 V Innovative by tradition. Control unit SG-EFS 104/4L EN Operating instructions Version 2 1004128 SG-EFS 104/4L AC/DC 24 V Original instructions Mayser GmbH & Co. KG Örlinger Straße 1 3 89073 Ulm GERMANY

More information

Operating instructions Optical distance sensor. OID20x / / 2014

Operating instructions Optical distance sensor. OID20x / / 2014 Operating instructions Optical distance sensor OID0x 800005 / 00 08 / 01 Contents 1 Preliminary note... 1.1 Symbols used... 1. Warning signs used... Safety instructions... Functions and features...5.1

More information

SAFETY RELAY YRB-4EML-31S MAIN FEATURES

SAFETY RELAY YRB-4EML-31S MAIN FEATURES SAFETY RELAY TYPE 4 SAFETY PROTECTION DEVICE FOR SAFETY LIGHT CURTAINS/BARRIERS MAIN FEATURES For safety light curtains and access control barriers, emergency stop, door switch Safety Integrity Level (SIL)

More information

Original operating instructions. Fail-safe SmartPLC with Profinet slave interface AC402S /00 06/2016

Original operating instructions. Fail-safe SmartPLC with Profinet slave interface AC402S /00 06/2016 Original operating instructions Fail-safe SmartPLC with Profinet slave interface AC402S UK 80237419/00 06/2016 Contents 1 Preliminary note...4 1.1 Notes on this document...4 1.2 Symbols used...4 2 Safety

More information

PSR-MS60. Safety relay for emergency stop, safety door and light grid monitoring. Data sheet. 1 Description

PSR-MS60. Safety relay for emergency stop, safety door and light grid monitoring. Data sheet. 1 Description SILCL IEC 62061 Safety relay for emergency stop, safety door and light grid monitoring Data sheet 106171_en_01 PHOENIX CONTACT 2015-05-19 1 Description Intended Use The PSR-MS60 safety relay can be used

More information

Operating instructions. Monitor FS-2 / FS-2N / / 2013

Operating instructions. Monitor FS-2 / FS-2N / / 2013 Operating instructions Monitor FS-2 / FS-2N UK 7390959 / 00 01 / 2013 Contents 1 Preliminary note...4 1.1 Symbols used...4 1.2 Warning signs used...4 2 Safety instructions...5 2.1 General...5 2.2 Target

More information

Operating instructions Optical distance sensor. OID20x / / 2015

Operating instructions Optical distance sensor. OID20x / / 2015 Operating instructions Optical distance sensor OID20x 80228367 / 00 03 / 2015 Contents 1 Preliminary note...3 1.1 Symbols used...3 2 Safety instructions...3 3 Functions and features...4 3.1 Applications...4

More information

Operating instructions Diagnostic electronics for vibration sensors VSE002 / VXE002 / VXE003 VYE001 / VYE002 / VYE003 / VYE /01 05/2015

Operating instructions Diagnostic electronics for vibration sensors VSE002 / VXE002 / VXE003 VYE001 / VYE002 / VYE003 / VYE /01 05/2015 Operating instructions Diagnostic electronics for vibration sensors VSE00 / VXE00 / VXE00 VYE00 / VYE00 / VYE00 / VYE0 80677/0 05/05 Contents Preliminary note... Safety instructions... Functions and features...

More information

Operating instructions AC010S Compact AS-i E-STOP safety module

Operating instructions AC010S Compact AS-i E-STOP safety module Operating instructions AC010S Compact AS-i E-STOP safety module Sachnr. 7390636_/00 05/2007 Contents Safety instructions............................. 3 Installation / Setup............................

More information

PSR DC/ESP4/2X1/1X2

PSR DC/ESP4/2X1/1X2 PSR-...- 24DC/ESP4/2X1/1X2 Safety relay for emergency stop and safety door monitoring Data sheet 100516_en_05 PHOENIX CONTACT 2013-11-21 1 Description The safety relay can be used for emergency stop and

More information

Phone: Fax: Web: -

Phone: Fax: Web:  - In automated systems, sensors and actuators must interact with one another functionally and safely. The necessary coordination is performed by the programmable Safety Controller. The controller monitors

More information

to 12a Added Standard and Electrical requirements for UL table 1.1

to 12a Added Standard and Electrical requirements for UL table 1.1 Document changes and version status C-DIAS SAFETY DIGITAL INPUT MODULE CSDI 162 Change date Affected page(s) Changes/expansions/corrections Version 19.12.2013 12 to 12a Added Standard and Electrical requirements

More information

CONFIGURABLE SAFETY RELAYS

CONFIGURABLE SAFETY RELAYS CONFIGURABLE SAFETY RELAYS The cycle control function of the configurable MSI allows efficient semi-automatic processes Special features Single or double-cycle operation with 0 s / 0 min time monitoring

More information

Operating instructions Optical distance sensor O1D / / 2008

Operating instructions Optical distance sensor O1D / / 2008 Operating instructions Optical distance sensor O1D155 UK 704391 / 01 11 / 2008 Contents 1 Preliminary note...4 1.1 Symbols used...4 2 Safety instructions...4 3 Functions and features...5 3.1 Applications...5

More information

SECTION 16 LED DIAGNOSTIC FEATURES: EXPANSION UNITS: SCR-31P-i. SCR-73-i. SEU-31-i. SCR-31-42TD-i. SEU-31TD-i

SECTION 16 LED DIAGNOSTIC FEATURES: EXPANSION UNITS: SCR-31P-i. SCR-73-i. SEU-31-i. SCR-31-42TD-i. SEU-31TD-i SECTION 16 VIPER Safety Relays Type: SCR-i (with added diagnostics) SAFETY RELAY FUNCTION: IDEM s VIPER SCR-i range of Safety Relays have been designed in accordance with EN60204-1 for safety circuits

More information

PSR UC/ESAM4/3X1/1X2/B

PSR UC/ESAM4/3X1/1X2/B Safety relay for emergency stop and safety door monitoring Data sheet 105318_en_02 PHOENIX CONTACT 2014-06-13 1 Description The safety relay can be used in safety circuits according to EN 60240-1 and IEC

More information

Operating instructions Monitor FD-2 DR2005 DR / / 2007

Operating instructions Monitor FD-2 DR2005 DR / / 2007 Operating instructions Monitor FD-2 DR2005 DR2006 UK 1 2 3 4 5 6 7 8 9 10 11 12 7390342 / 01 07 / 2007 CH1CH2 CH3CH4RUNPRGTST KEY 13 14 15 16 17 18 19 20 21 22 23 24 Content 1 Safety instructions...4 2

More information

Safety Technique. SAFEMASTER C Multifunction Safety Module BH 5910

Safety Technique. SAFEMASTER C Multifunction Safety Module BH 5910 Safety Technique SAFEMASTER C Multifunction Safety Module BH 59 47 Block Diagram A+ A S S S4 S S S S4 S S S S4 S S4 S4 S44 S4 PTC Galvanic separation Monitoring logic Monitoring logic Galvanic separation

More information

Operating instructions. Monitor FR-1 / FR-1N / / 2013

Operating instructions. Monitor FR-1 / FR-1N / / 2013 Operating instructions Monitor FR-1 / FR-1N UK 7390953 / 00 01 / 2013 Contents 1 Preliminary note...4 1.1 Symbols used...4 1.2 Warning signs used...4 2 Safety instructions...5 2.1 General...5 2.2 Target

More information

AS-Interface Safety at Work

AS-Interface Safety at Work AS-Interface Safety at Work Safety Monitor, Coupling adjacent AS-i networks with the Safety Monitor provides the option of a cross-network E-Stop connection and a global restart, especially with large

More information

MSR178DP. Description. Features. Specifications

MSR178DP. Description. Features. Specifications MSR178DP Description The MSR178DP is a multi-function time-delay relay for use in safety circuits. It can be configured by the user to perform on-delay, offdelay or single-pulse modes. It is used for applications

More information

Installation instructions Inclination sensor EC2019 EC / / 2013

Installation instructions Inclination sensor EC2019 EC / / 2013 Installation instructions Inclination sensor UK EC219 EC245 739215 / 3 1 / 213 Inhalt 1 Safety instructions 3 2 Mounting 4 3 Electrical connection 4 4 Dimensions 4 5 Technical Data 5 6 Characteristics

More information

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors Safety relay for monitoring E-STOP pushbuttons, safety gates and light barriers. Approvals Block diagram Unit features Positive-guided relay outputs: 6 safety contacts (N/O), instantaneous 4 auxiliary

More information

Technical data. Dimensions: see page 116. ): 4 kv Rated insulation voltage (U i Over-voltage category: Power supply. Rated operating voltage (Un):

Technical data. Dimensions: see page 116. ): 4 kv Rated insulation voltage (U i Over-voltage category: Power supply. Rated operating voltage (Un): Safety module CS AR-91, according to EN 81 Safety modules for the lift automatic floor levelling operation according to EN 81 Main functions For safety applications up to SIL 3 / PL e Choice between automatic

More information

AS-i Safety Relay Output Module with Diagnostic Slave

AS-i Safety Relay Output Module with Diagnostic Slave AS-i Safety Relay Output Module with Diagnostic Slave User Manual...supports the requirements for AS-i Safety up to SIL3 Revision date: 2016-03-9 Subject to modifications without notice. Generally, this

More information

Polymer Electric. Operating Instructions. Control Unit SG-EFS 1X4 ZK2/1 8k2. Version 3

Polymer Electric. Operating Instructions. Control Unit SG-EFS 1X4 ZK2/1 8k2. Version 3 Operating Instructions Control Unit SG-EFS 1X4 ZK2/1 8k2 Version 3 1003100 SG-EFS 104 ZK2/1 8k2 24 V=/~ 7500354 SG-EFS 134 ZK2/1 8k2 230 V~ Original instructions GmbH & Co. KG Polymer Electric Örlinger

More information

PSR-SCP- 24DC/SSM/2X1 PSR-SPP- 24DC/SSM/2X1

PSR-SCP- 24DC/SSM/2X1 PSR-SPP- 24DC/SSM/2X1 PSR-SCP- DC/SSM/2X1 PSR-SPP- DC/SSM/2X1 Safety Relay With Downtime Monitoring INTERFACE Data Sheet PHOENIX CONTACT - 05/2006 Description The PSR-...- DC/SSM/2X1 safety relay can be used in safety circuits

More information

Operating instructions Memory plug E /02 11/2011

Operating instructions Memory plug E /02 11/2011 Operating instructions Memory plug E30398 UK 704930/02 11/2011 Contents 1 Preliminary note...3 1.1 Symbols used...3 1.2 Terms used...3 2 Safety instructions...4 3 Factory setting...4 4 Functions and features...5

More information

Bul. 440R Guardmaster Safety Relays (DI, DIS, SI, CI, EM, and EMD) Selection Guide

Bul. 440R Guardmaster Safety Relays (DI, DIS, SI, CI, EM, and EMD) Selection Guide Bul. 440R Guardmaster Safety Relays (DI, DIS, SI, CI, EM, and EMD) Selection Guide Description The new generation of Guardmaster Safety Relays addresses the broad scope of applications in the intricate

More information

Operating instructions Safety-monitoring module SE-304 C. 1. About this document. Content

Operating instructions Safety-monitoring module SE-304 C. 1. About this document. Content 6 Disassembly and disposal 6.1 Disassembly....4 6.2 Disposal...4 Operating instructions.............pages 1 to 6 Original 7 Appendix 7.1 EU Declaration of conformity...5 7.2 Mounting and inspection protocol...6

More information

ENGLISH. Terminals 13, 14, 23, 24, 43, 44, 53, Web: Phone: Toll Free:

ENGLISH. Terminals 13, 14, 23, 24, 43, 44, 53, Web:   Phone: Toll Free: Operating Manual ENGLISH 0266691 PRSU/M2SI Multifunctional Downstream Device ORIGINAL Before installing, operating or maintaining the device, read underst this manual. DANGER Dangerous tension. Danger

More information

AS-i Safety Relay Output Module with Diagnostic Slave

AS-i Safety Relay Output Module with Diagnostic Slave AS-i Safety Relay Output Module with Diagnostic Slave User Manual Revision date: 2013-01-30...supports the requirements for AS-i Safety up to SIL3 Subject to modifications without notice. Generally, this

More information

ETD-BL-1T-OFF-CC- 10S

ETD-BL-1T-OFF-CC- 10S Timer relay with off delay (with control contact) and adjustable time Data sheet 103617_en_03 1 Description PHOENIX CONTACT - 2013-09-16 Features Compact timer relay in 6.2 mm housing for controlling time

More information

Technical data. Housing Polyamide housing PA 66, self-extinguishing V0 acc. to UL 94. Supply Rated supply voltage (U n

Technical data. Housing Polyamide housing PA 66, self-extinguishing V0 acc. to UL 94. Supply Rated supply voltage (U n Safety module CS AT 0 Module for emergency stops, end position monitoring for movable guards with delayed contacts at the opening of the input channels, semiconductor outputs (e.g. light barriers and magnetic

More information

Operating instructions Safety-monitoring module AES 1235 AES About this document. Content

Operating instructions Safety-monitoring module AES 1235 AES About this document. Content 1. About this document DE Betriebsanleitung...............Seiten 1 bis 6 Übersetzung der Originalbetriebsanleitung 1.1 Function This operating instructions manual provides all the information you need

More information

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous Two-hand control unit for press controllers and safety circuits Approvals Unit features Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous 1 auxiliary contact (N/C), instantaneous 1

More information

Operating instructions Safe AS-i input module ASIM-C-M About this document. Content

Operating instructions Safe AS-i input module ASIM-C-M About this document. Content 7 Set-up and maintenance 7.1 Functional testing....10 7.2 Maintenance...10 EN Operating instructions.............pages 1 to 6 Original 8 Disassembly and disposal 8.1 Disassembly....10 8.2 Disposal...10

More information

Operating instructions RFID evaluation unit DTE / / 2016

Operating instructions RFID evaluation unit DTE / / 2016 Operating instructions RFID evaluation unit DTE101 80005398 / 01 06 / 2016 Contents 1 Preliminary note...4 1.1 Notes on this document...4 1.2 Symbols used...4 2 Safety instructions...4 2.1 General...4

More information

Operating instructions Safety-monitoring module AES 1235 AES About this document. Content

Operating instructions Safety-monitoring module AES 1235 AES About this document. Content 8 Appendix 8.1 Wiring examples...3 8.2 Integral System Diagnostics (ISD)....4 9 EU Declaration of conformity Operating instructions.............pages 1 to 6 Original x.000 / 11.2017 / v.a. - 101172890-

More information

PSR-SCP- 24DC/SDC4/2X1/B PSR-SPP- 24DC/SDC4/2X1/B

PSR-SCP- 24DC/SDC4/2X1/B PSR-SPP- 24DC/SDC4/2X1/B PSR-SCP- 24DC/SDC4/2X1/B PSR-SPP- 24DC/SDC4/2X1/B Safety Relay for Emergency Stop and Safety Door Circuits INTERFACE Data Sheet 102858_02_en PHOENIX CONTACT - 12/2006 Description The PSR-...- 24DC/SDC4/2X1/B

More information

Safety relays PNOZsigma

Safety relays PNOZsigma Safety relays PNOZsigma Configuration guide, safety relays PNOZsigma Technical catalogue 3.2 November 2008 edition Why does Pilz offer more? Because the integrality of our business activities is what sets

More information

Dimensions. Model Number. Electrical connection emitter. Features. Electrical connection receiver. Product information. Pinout OBE12M-R100-S2EP-IO-V31

Dimensions. Model Number. Electrical connection emitter. Features. Electrical connection receiver. Product information. Pinout OBE12M-R100-S2EP-IO-V31 OBEM-R00-SEP-IO-V Dimensions. 8.7. 7..9. M (x).. ø... 0 9.9 7. 7. Release date: 08-06-08 :0 Date of issue: 08-06-08 80998_eng.xml Model Number OBEM-R00-SEP-IO-V Thru-beam sensor with -pin, M8 x connector

More information

Operating instructions (short version) Safety monitor AS-Interface Safety at Work ASM E1-R2 ASM E2-R2/R2. 1. About this document.

Operating instructions (short version) Safety monitor AS-Interface Safety at Work ASM E1-R2 ASM E2-R2/R2. 1. About this document. 1. About this document Operating instructions.............pages 1 to 6 Translation of the original operating instructions 1.1 Function This operating instructions manual provides all the information you

More information

Added Standard and Electrical requirements for UL table Switching-off inductive loads 1.2

Added Standard and Electrical requirements for UL table Switching-off inductive loads 1.2 C-DIAS SAFETY CPU CSCP 012 Document changes and version status Change date Affected page(s) Changes/expansions/corrections Version 19.12.2013 14 Added Standard and Electrical requirements for UL table

More information

Performance Level PL d. Safety Category Type 3. Automatic reset / Manual reset. Very short reaction times. Connection of several signal transmitters

Performance Level PL d. Safety Category Type 3. Automatic reset / Manual reset. Very short reaction times. Connection of several signal transmitters E L E K T R O N I K Data sheet Safety Relais STM STK 41-322 RLU for Safety-contact-mat STM PL d ISO 13849 Typ 3 EN 61496 Kat. 3 ISO 13849 SIL 2 EN 61508 Performance Level PL d Safety Category Type 3 Automatic

More information

Operating instructions Control monitor for temperature sensors TR /00 04/2011

Operating instructions Control monitor for temperature sensors TR /00 04/2011 Operating instructions Control monitor for temperature sensors TR7432 704773/00 04/20 Contents Preliminary note3. ymbols used 3 2 afety instructions 3 3 Functions and features 4 4 Function 4 4. Communication,

More information

Operating instructions Optical distance sensor O1D / / 2012

Operating instructions Optical distance sensor O1D / / 2012 Operating instructions Optical distance sensor O1D106 UK 704204 / 01 08 / 2012 Contents 1 Preliminary note...4 1.1 Symbols used...4 1.2 Warning signs used...4 2 Safety instructions...4 3 Functions and

More information

PSR-PC50. SIL 3 coupling relay for safety-related switch on. Data sheet. 1 Description

PSR-PC50. SIL 3 coupling relay for safety-related switch on. Data sheet. 1 Description SIL 3 coupling relay for safety-related switch on Data sheet 105818_en_01 PHOENIX CONTACT 2014-08-18 1 Description The PSR-PC50 SIL coupling relay can be used for power adaptation and electrical isolation

More information

Two-hand control unit

Two-hand control unit Unit features Safety features Gertebild ][Bildunterschrift_Zweihand Two-hand control unit for press controllers and safety circuits Approvals Gertemerkmale Positive-guided relay outputs: 3 safety contacts

More information

Options for ABB drives. User s manual Emergency stop, stop category 0 (option +Q951) for ACS880-07/17/37 drives

Options for ABB drives. User s manual Emergency stop, stop category 0 (option +Q951) for ACS880-07/17/37 drives Options for ABB drives User s manual Emergency stop, stop category 0 (option +Q951) for ACS880-07/17/37 drives List of related manuals Drive hardware manuals and guides ACS880-07 drives (560 to 2800 kw)

More information

Making Hazardous Operations Safe and Productive

Making Hazardous Operations Safe and Productive NEW Safety Guard Switching Unit G9SX-GS Making Hazardous Operations Safe and Productive Making Hazardous Operations Safe and Productive This new addition to the model of Flexible Safety Unit G9SX series

More information

Quick reference guide 3D sensor O3D3xx

Quick reference guide 3D sensor O3D3xx Quick reference guide 3D sensor O3D3xx 80271080 / 00 11 / 2017 Contents 1 Preliminary note...3 1.1 Symbols used...3 1.2 Warnings used...3 2 Safety instructions...4 2.1 Safety note...4 3 Functions and features...4

More information

SR103AM. User Information for SR103AM. Correct Use

SR103AM. User Information for SR103AM. Correct Use Correct Use The is a universal emergency stop safety switching device with three safe relay outputs that can quickly and safely stop the moving parts of a machine or system in case of danger. Applications

More information

Datasheet - SRB 301LC/B-24V

Datasheet - SRB 301LC/B-24V 27.01.2016-00:27:16h Datasheet - SRB 301LC/B-24V Guard door monitors and Safety control modules for Emergency Stop applications / General Purpose safety controllers (Series PROTECT SRB) / SRB 301LC/B Fit

More information

HR1S-AC Safety Relay Modules

HR1S-AC Safety Relay Modules HRS-AC Relay Modules Transistor output provided. Removable terminal block (HRS-AC52P) allows for easy module replacement. Fault diagnosis function with dual safety circuits. Internal relay operations can

More information

AS-i Safety Relay Output Module with Diagnostic Slave and 1 EDM Input

AS-i Safety Relay Output Module with Diagnostic Slave and 1 EDM Input Safety + standard I/O in one module Safety relay output with galvanically isolated contact sets, approved up to 230 V IEC 61508 SIL 3, EN ISO 13849-1/PLe Kat 4, EN 62061 SIL 3 Protection category IP20

More information

ASM1, ASM1E, ASM2E. AS-i Safety Monitor. Subject to change without prior notice. Technische Änderungen vorbehalten /02

ASM1, ASM1E, ASM2E. AS-i Safety Monitor. Subject to change without prior notice. Technische Änderungen vorbehalten /02 ASM1, ASM1E, ASM2E AS-i Safety Monitor 50101229-2009/02 Technische Änderungen vorbehalten Subject to change without prior notice Information on the use of the connecting and operating instructions These

More information

PSR-SCP- 24DC/URM4/4X1/2X2/B PSR-SPP- 24DC/URM4/4X1/2X2/B

PSR-SCP- 24DC/URM4/4X1/2X2/B PSR-SPP- 24DC/URM4/4X1/2X2/B Safety Relay as a Contact Extension Block INTERFACE Data Sheet PHOENIX CONTACT - 05/2006 Description The PSR-...- 24DC/URM4/4X1/2X2/B safety relay can be used as a contact extension block in safety circuits

More information

Dimensions. Model Number. Electrical connection. Features. Pinout. Indicators/operating means. Product information OQT150-R100-2EP-IO-V31

Dimensions. Model Number. Electrical connection. Features. Pinout. Indicators/operating means. Product information OQT150-R100-2EP-IO-V31 Dimensions.5 8.7 5.5.5. M (x)..5 7. 5.. 0 5.9 7. 9.95 Reveiver Emitter ø. Model Number Triangulation sensor (SbR) with -pin, M8 x connector Features Miniature design with versatile mounting options Multi

More information

BETRIEBSANLEITUNG TECHNICAL INSTRUCTION INTERFACE PSE2-SC-02 (24 V AC/DC) Version 1.4

BETRIEBSANLEITUNG TECHNICAL INSTRUCTION INTERFACE PSE2-SC-02 (24 V AC/DC) Version 1.4 Safety regulations - The unit should be installed and operated by persons, who are familiar with these instructions and the current regulations for safety at work and accident prevention. Follow local

More information

Control unit SG-EFS 104/2W. EN Operating instructions. Innovative by tradition. Version SG-EFS 104/2W 24 V=/~

Control unit SG-EFS 104/2W. EN Operating instructions. Innovative by tradition. Version SG-EFS 104/2W 24 V=/~ Innovative by tradition. Control unit SG-EFS 104/2W EN Operating instructions Version 0.9 1005196 SG-EFS 104/2W 24 V=/~ Original instructions Mayser GmbH & Co. KG Örlinger Straße 1 3 89073 Ulm GERMANY

More information

SR101A. User Information for SR101A. Correct Use

SR101A. User Information for SR101A. Correct Use Correct Use is the low-cost emergency stop safety relay with which machines and systems can be safely switched off by disconnecting the power supply. Internal fault monitoring takes place during restarting

More information

QUINT-PS/ 1AC/24DC/ 5

QUINT-PS/ 1AC/24DC/ 5 Extract from the online catalog QUINT-PS/ 1AC/24DC/ 5 Order No.: 2866750 DIN rail power supply unit 24 V DC/5 A, primary switched-mode, 1- phase. The SFB technology (Selective Fuse Breaking Technology)

More information

G9SX-GS. Safety Guard Switching Unit. A Safety Measure for Hazardous Operations That Does Not Lower Productivity. Auto Switching Function

G9SX-GS. Safety Guard Switching Unit. A Safety Measure for Hazardous Operations That Does Not Lower Productivity. Auto Switching Function Safety Guard Switching Unit CSM DS_E_6_1 A Safety Measure for Hazardous Operations That Does Not Lower Productivity Two functions support two types of application: Auto switching: For applications where

More information

Non-Contact Safety System CES-AZ

Non-Contact Safety System CES-AZ Evaluation unit CE-AZ-AE-01B/ CE-AZ-UE-01B 1) 2) 1 read head can be connected 2 safety outputs (relay contacts with 2 internally connected NO contacts per output) tart button and feedback loop can be connected

More information

E-STOP relay, safety gate monitor

E-STOP relay, safety gate monitor Safety relay for monitoring E-STOP pushbuttons, safety gates and light barriers. Approvals Unit features Positive-guided relay outputs: 2 safety contacts (N/O), instantaneous 1 semiconductor output Connection

More information

Safety Switches CES-AR/CET-AR

Safety Switches CES-AR/CET-AR CES-A-L XXXXXX Safety Switches Component overview for non-contact safety switches Connection cable Safety switch Actuator Bolt CES-A-BBA Page 1 CES-A-BCA Page 1 Page 10 CES-AR-C01-... Page 10 CES-A-BPA

More information

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors Unit features Safety features Gertebild ][Bildunterschrift_NOT_Sch.tuer_Licht Safety relay for monitoring E-STOP pushbuttons, safety gates and light beam devices Approvals Gertemerkmale Positive-guided

More information

Operating instructions Pressure sensor. PN50xx / / 2010

Operating instructions Pressure sensor. PN50xx / / 2010 Operating instructions Pressure sensor PN50xx 704789 / 00 05 / 2010 Contents 1 Preliminary note...3 1.1 Symbols used...3 2 Safety instructions...3 3 Functions and features...4 4 Function...5 4.1 Processing

More information

Operating instructions. Monitor FS-1 / FS-1N / / 2013

Operating instructions. Monitor FS-1 / FS-1N / / 2013 Operating instructions Monitor FS-1 / FS-1N UK 7390958 / 00 01 / 2013 Contents 1 Preliminary note...4 1.1 Symbols used...4 1.2 Warning signs used...4 2 Safety instructions...5 2.1 General...5 2.2 Target

More information

Datasheet SRB301ST 24V (V.2)

Datasheet SRB301ST 24V (V.2) 26.10.2016 05:03:31h Datasheet SRB301ST 24V (V.2) Guard door monitors and Safety control modules for Emergency Stop applications / General Purpose safety controllers (Series PROTECT SRB) / SRB301ST Suitable

More information

Operating instructions Enabling switch (handle switch) ZSD5 ZSD6. 1. About this document. Content. 7 Appendix 7.1 Wiring example...

Operating instructions Enabling switch (handle switch) ZSD5 ZSD6. 1. About this document. Content. 7 Appendix 7.1 Wiring example... 7 ppendix 7.1 Wiring example...5 8 Declaration of conformity 8.1 EC Declaration of conformity...6 Operating instructions.............pages 1 to 6 Translation of the original operating instructions x.000

More information

QUINT-BUFFER/24DC/24DC/40

QUINT-BUFFER/24DC/24DC/40 Buffer module Data sheet 105496_en_01 PHOENIX CONTACT 2013-11-01 1 Description The QUINT BUFFER buffer module combines the electronic switchover unit and power storage in the same housing. The buffer module

More information

FACTORY AUTOMATION. MANUAL VAA-2E-G4-SE Original Instructions Version 1.1

FACTORY AUTOMATION. MANUAL VAA-2E-G4-SE Original Instructions Version 1.1 FACTORY AUTOMATION MANUAL VAA-2E-G4-SE Original Instructions Version 1.1 With regard to the supply of products, the current issue of the following document is applicable: The General Terms of Delivery

More information

Technical data. Safety parameters: see page 333. DC maximum residual ripple: 10% Supply voltage tolerance: DC consumption: Control circuit

Technical data. Safety parameters: see page 333. DC maximum residual ripple: 10% Supply voltage tolerance: DC consumption: Control circuit Safety module CS DM-01 Technical data Housing PA 6.6 polyamide housing, self-extinguishing, V0 acc. to UL 94 Protection degree IP40 (housing), IP20 (terminal strip) Dimensions see page 283, design A Two-hand

More information

Polymer Electric. Operating Instructions. Control Unit SG-RST 153. Version 0.3

Polymer Electric. Operating Instructions. Control Unit SG-RST 153. Version 0.3 Operating Instructions Control Unit SGRST 153 Version 0.3 1004931 SGRST 153 Original instructions GmbH & Co. KG Örlinger Straße 1 3 89073 Ulm GERMANY Tel.: +49 731 20610 Fax: +49 731 2061222 EMail: info.ulm@mayser.com

More information

Vital. Safety controller. Approvals: Control of: Features: Entire safety system based on the dynamic safety circuit.

Vital. Safety controller. Approvals: Control of: Features: Entire safety system based on the dynamic safety circuit. Safety controller Vital Approvals: TÜV Nord Vital 1 TÜV Rheinland Vital and 3 Control of: Entire safety system based on the dynamic safety circuit. Features: Vital is based on a single channel safety concept

More information

Datasheet - SRB 402EM-24V

Datasheet - SRB 402EM-24V Print - Create PDF - Create EXCEL file 20.04.2011-18:31:35h Datasheet - SRB 402EM-24V Output expanders / SRB 402EM Expander module for contact expansion 4 safety contacts, STOP 0 2 Signalling outputs (Minor

More information

Safety Technique. SAFEMASTER Light Curtain Controller With Selectable Operating Modes BH 5902/01MF2

Safety Technique. SAFEMASTER Light Curtain Controller With Selectable Operating Modes BH 5902/01MF2 Safety Technique SAFEMASTER Light Curtain Controller With Selectable Operating Modes BH 5902/01MF2 0237093 Block Diagram A1+ A2 S12 S14 S21 S22 S24 S23 S44 S43 13 23 33 PTC monitoring logic 1 galvanic

More information

Operating Instructions

Operating Instructions Innovative by tradition. Operating Instructions Control Unit SG-RSV 239 Version 1 1003986 SG-RSV 239/24 24 V= 1005372 SG-RSV 239/36 36 V= 1003271 SG-RSV 239 50-150 V= Mayser GmbH & Co. KG Örlinger Straße

More information

Options for ABB drives. User s manual Emergency stop, stop category 1 (option +Q964) for ACS880-07/17/37 drives

Options for ABB drives. User s manual Emergency stop, stop category 1 (option +Q964) for ACS880-07/17/37 drives Options for ABB drives User s manual Emergency stop, stop category 1 (option +Q964) for ACS880-07/17/37 drives List of related manuals Drive hardware manuals and guides ACS880-07 drives (560 to 2800 kw)

More information

Technical Data. Dimensions

Technical Data. Dimensions Model Number Features 50 mm flush -wire DC S Technical Data specifications Switching function Normally open (NO) Output type PNP Rated operating distance s n 50 mm Installation flush Output polarity DC

More information