Ethernet Media. Technical Data. Bulletin Numbers 1585, 1585A, 1585BP, 1585BT, 1585BX, 1585BZ, 1585D, 1585J
|
|
- Damon Griffin
- 6 years ago
- Views:
Transcription
1 Technical Data Ethernet Media Bulletin Numbers 585, 585A, 585BP, 585BT, 585BX, 585BZ, 585D, 585J Topic Page Summary of Changes Introduction Cable Spools Unshielded Twisted Pair Shielded Twisted Pair (Foil and Braided Shield) 600V Ethernet Cable 5 Cordsets and Patchcords 6 RJ5 6 RJ5 Gigabit 7 RJ5 Red 8 M Flex-rated 9 M Receptacle Flex-rated M X-code Flex-rated Gigabit M Red Patchcords and Field Attachable Die-cast Zinc RJ5 Connector, Variant Thermoplastic RJ5 Connector, Variant 6 Field Attachable 8 RJ5 Connector 8 M Insulation Displacement Connectors (IDC) 0 M to RJ5 Bulkhead Connector
2 Summary of Changes This publication contains updated nominal outer diameter specifications on pages 6, 7, 8, 9,,, and. Additional Resources These documents contain additional information concerning related products from Rockwell Automation. Resource Industrial Ethernet Media Brochure, publication 585-BR00 Description Provides an overview of Ethernet Media products that Rockwell Automation offers. You can view or download publications at To order paper copies of technical documentation, contact your local Allen-Bradley distributor or Rockwell Automation sales representative. Introduction As Ethernet is increasingly used in industrial control, survival of physical media in rugged or harsh environments is becoming a necessity. The high speed of network protocol allows it to be used in applications where other networks fall short. EtherNet/IP uses both standard Ethernet and TCP/IP technologies and an open application layer protocol that is called the Control and Information Protocol (CIP). This application layer is the same as used in DeviceNet and ControlNet networks. Rockwell Automation Cat 5e Ethernet cables are designed to supply a network connection with excellent reliability in harsh surroundings. By optimizing the balance of twisted-pair conductors inside a robust Thermoplastic Elastomer (TPE) jacket, data is protected from noise, chemicals, and mechanical issues to M I C E environmental protection levels. The cable is available in RJ5 patchcords for IP0 applications or in four-pin D-coded M patchcords for IP67 applications where high vibration, fluids, and other contaminants can threaten the reliability of a network. M D-code field attachable insulation displacement connectors (IDC) are available in both shielded and unshielded housings with male or female connectors. Male eight-pin RJ5 connectors are available in both a crimp termination and a toolless IDC connector for custom cabling. Rockwell Automation M to RJ5 bulkhead connectors provide an elegant transition for network architecture from an IP0 setting to an IP67 environment. The adapter can be used to connect remote junction boxes or implement an On- Machine solution with Armor I/O products. The Rockwell Automation Ethernet media portfolio provides connectivity with excellent reliability to maintain network integrity and reduces costly downtime from troubleshooting. Rockwell Automation Publication 585-TD00D-EN-P - April 07
3 Cable Spools Unshielded Twisted Pair Features - and 8-conductor styles Unshielded cable types, Cat 5e AWG conductors Twisted pairs maintain signal balance through cable to provide high noise immunity and return loss Designed to ODVA EtherNet/IP specifications and ISO IEC 70 Unshielded Ethernet Cable Spool Suitable for high noise environments M I C E Riser PVC cables are used for general-purpose environments TPE robotic cable is used for flex applications, transmission-tested to 0 million cycles Plenum PVC cable is used for air duct applications TPE cable meets channel transmission performance to 0 million flexes Attributes Bulletin 585 Certifications Cable Type Conductor Material Bend Radius Data Rate Operating Temperature Voltage UL Listed and CEC Unshielded - and -pair, Cat 5e Tinned copper stranded 0 million cycles at 0 x diameter (TPE cable) Up to GB/s C ( F) 00V Cable and Color Code Two-pair Four-pair White/Orange White/Green Orange Green White/Orange Orange White/Green Blue White/Blue Green White/Brown Brown Rockwell Automation Publication 585-TD00D-EN-P - April 07
4 Shielded Twisted Pair (Foil and Braided Shield) Attributes Bulletin 585 Certifications Conductor Material Insulation Material Bend Radius Data Rate Voltage UL Listed and CEC Tinned copper stranded High-density polyethylene 0 million cycles at 0 x diameter (TPE cable) Up to GB/s, Cat 5e 00V Shielded Ethernet Cable Spool Cable and Color Code Two-pair Four-pair White/Orange White/Green Orange Green White/Orange Orange White/Green Blue White/Blue Green White/Brown Brown Rockwell Automation Publication 585-TD00D-EN-P - April 07
5 600V Ethernet Cable Attributes Bulletin 585 Certifications Conductor Material Insulation Material Diameter Cable Rating UL and c-ul Listed Thin copper stranded Perfluoroalkoxy copolymer and polyolefin 8. ± 0.8 mm (0. ± 0.05 in.) UL, c-ul TYPE CMG; UL PLTC or UL AWM C 600V, TIA 568B RJ5 Cordset600V Cable and Color Code Four-pair Figure - RH5 IDC Connector 5. (.09) Ref 9. (.5) Ref View Shown with Cap. (0.56) Ref.9 (0.55) Ref 87 B PC 87 White/Orange Orange White/Green Blue White/Blue Green White/Brown Brown 6.6 (0.6) Ref View Shown without Cap 5. (.0) Ref.8 (0.05) Ref Pinout.68 (0.6) Ref Face View RJ5 Pinout 8-Pin Figure - RJ5 90 Left and Right Angle Patchcord (.5) 6. (.) (.5) 6. (.) Color Code A Orange White/Green Blue 5 White/Blue 6 Green 7 White/Brown 8 Brown TxData + TxData - Recv Data + Recv Data - Figure - RJ5 Cordset and Patchcord 8.9 (.9) Rockwell Automation Publication 585-TD00D-EN-P - April 07 5
6 Cordsets and Patchcords RJ5 Features Flex-rated TPE, PVC, and plenum cables for various applications Teal cable jacket Rugged strain relief and hitch mechanism to maintain network integrity RJ5 Cordset Suitable environments M I C E Attributes Certifications Connectors Pinout Bulletin 585J UL Listed RJ5 Male to RJ5 Male, Cat 5e Cable Type Unshielded - and 8-conductor, AWG, Industrial Cat 5e Shielded 8-conductor 6 AWG Industrial Cat 5e Enclosure Type Rating IP0 Nominal Outer Diameter 5.8 mm (0. in.) ±0% Operating Temperature C (- +0 F) Voltage 00V Face View RJ5 Pinout 8-Pin Color Code A Orange White/Green Blue 5 White/Blue 6 Green 7 White/Brown 8 Brown 8-Pin TxData + TxData - Recv Data + Recv Data Orange White/Green 5 6 Green 7 8 -Pin TxData + TxData - Recv Data + Recv Data - Figure - Cordsets/Patchcords 8.9 (.9) Example of Cordset Example of Patchcord 6 Rockwell Automation Publication 585-TD00D-EN-P - April 07
7 RJ5 Gigabit Features Flex-rated TPE cables for various applications Teal cable jacket Rugged strain relief and latch mechanism to maintain network integrity RJ5 Cordset, Cat 6 Suitable environments M I C E Attributes Bulletin 585J Certifications UL Listed Connectors RJ5 Male to RJ5 Male, Cat 6 Cable Type Shielded, 8-conductor, AWG, Industrial Cat 6 Enclosure Type Rating IP0 Nominal Outer Diameter 5.8 mm (0. in.) ±0% Operating Temperature C (- +0 F) Voltage 00V Pinout Face View RJ5 Pinout 8-Pin Pin Color Code Pin 8 Side A Plug Pin T568B Side B Plug Pin 000BASE-T BI_DA+ (Bi-directional pair +) Orange BI_DA- (Bi-directional pair -) White/Green BI_DB+ (Bi-directional pair +) Blue BI_DC+ (Bi-directional pair +) 5 White/Blue 5 BI_DC- (Bi-directional pair -) 6 Green 6 BI_DB- (Bi-directional pair -) 7 White/Brown 7 BI_DD+ (Bi-directional pair +) 8 Brown 8 BI_DD- (Bi-directional pair -) Figure 5 - Cordsets/Patchcords 8.9 (.9) Example of Cordset Example of Patchcord Rockwell Automation Publication 585-TD00D-EN-P - April 07 7
8 RJ5 Red Attributes Certifications Connectors Cable Type Bulletin 585J UL Listed RJ5 Male to RJ5 Male, Cat 5e Unshielded, - and 8-conductor, AWG, Industrial Cat 5e Shielded, 8-conductor, 6 AWG, Industrial Cat 5e Enclosure Type Rating IP0 Nominal Outer Diameter 5.8 mm (0. in.) ±0% Operating Temperature C (- +0 F) RJ5 Red Cordset Pinout Face View RJ5 Pinout 8-Pin Color Code Pin -Pin A Orange White/Green Blue 5 White/Blue 6 Green 7 White/Brown 8 Brown TxData + TxData - Recv Data + Recv Data - Orange White/Green 5 6 Green 7 8 TxData + TxData - Recv Data + Recv Data - Figure 6 - Cordsets/Patchcords 8.9 (.9) Example of Cordset Example of Patchcord.70 (.5) Right Angle Left Angle 8 Rockwell Automation Publication 585-TD00D-EN-P - April 07
9 M Flex-rated Features Over molded housing suitable for IP67 applications and harsh industrial environments where extreme vibration, shock, chemicals, and temperature are found. Flex-rated cable (must be tied down and not flexed within 6 in. of the connector). Custom termination of single-ended cordsets with one of several field attachable connectors. Designed to ODVA EtherNet/IP specifications and ISO IEC 70, IEC 698. Twisted pairs maintain signal balance through cable to provide high noise immunity and return loss. Suitable for noise environments M I C E. -Pin M D-Code Cordset General Attributes Cable Bulletin 585D Coupling Nut Material Nickel-plated brass Housing Material Polyurethane (PUR) Contact Material Gold-plated brass Enclosure Type Rating IP67 Nominal Outer Diameter 5.8 mm (0. in.) ±0% Bend Radius 0 x cable diameter Operating Temperature C ( F) Cable Style Cable Type Wire Size [AWG] Cable O.D. [mm (in.)] Cable Rating TPE, high flex, unshielded PUR, foil and braided shield, high flex, halogen free PVC, 600V rated, foil shield conductor, unshielded twisted pair (UTP), teal conductor, shielded twisted pair (STP), teal conductor, shielded twisted pair (STP), teal 5.6 (0.) Weld splatter, sunlight, and oil resistant; UL CM, CMX; c-ul CM; TIA 568B (0.) C(ETL)US TYPE CMX; TIA 568B 8. (0.) (UL) CMX, CMR; c-ul CMG; (UL) PLTC or AWM C 600V; TIA 568B Rockwell Automation Publication 585-TD00D-EN-P - April 07 9
10 Pinout Face View Pinout Face View RJ5 Pinout -Pin Face View RJ5 Pinout 8-Pin Color Code Pin -Pin A White-Orange White-Green Orange Green Orange White/Green Blue 5 White/Blue 6 Green 7 White/Brown 8 Brown TxData + TxData - Recv Data + Recv Data - Orange White/Green 5 6 Green 7 8 TxData + TxData - Recv Data + Recv Data - Figure 7 - Cordsets/Patchcords 7 (.85) Example of M to M Patchcord Example of Cordset Example of M to RJ5 Patchcord 0 Rockwell Automation Publication 585-TD00D-EN-P - April 07
11 M Receptacle Flex-rated Attribute Bulletin 585D Coupling Nut Material Nickel-plated brass Contact Material Gold-plated brass Cable Type Unshielded teal TPE, -conductor, stranded tinned wire, Industrial Cat 5e Enclosure Type Rating IP67 Nominal Outer Diameter 5.8 mm (0. in.) ±0% Mounting Front-mount Operating Temperature C ( F) Cable Rating TIA 568B, flex-rated, AWG, UL, c-ul Voltage 00V -Pin M D-Code Receptacle to RJ5 Patchcord Pinout Face View Pinout (Female) Face View RJ5 Pinout -Pin Color Code A White/Green Orange Green Orange White/Green Blue 5 White/Blue 6 Green 7 White/Brown 8 Brown TxData + TxData - Recv Data + Recv Data - Figure 8 - Cordsets/Patchcords 9 (.5) 9.5 (0.77) 9.5 (0.77) M (0.06) (0.9) (.) (0.08) (0.) (0.7) (0.5) Dia. Dia. 0/SW8 Dia. PG9 M x Length (see table) 5.5 (0.) Dia.. (.7) x G Dia. 8 (0.7) Dia. M PIN RJ5 PIN 6 x 6 SW7 G Rockwell Automation Publication 585-TD00D-EN-P - April 07
12 M X-code Flex-rated Gigabit Features Over-molded housing suitable for IP67 applications and harsh industrial environments where extreme vibration, shock, chemicals, and temperature are found. Flex-rated cable (must be tied down and not flexed within 6 in. of the connector). 8-Pin M X-code Cordset, Cat 6 Designed to EtherNet/IP specifications and ISO IEC 80, IEC 698. Twisted pairs maintain signal balance through cable to provide high noise immunity and low return loss. Suitable for noise environments M I C E. Wiring Diagram Attributes Coupling Nut Material Housing Material Contact Material Bulletin 585D Nickel-plated brass Polyurethane (PUR) Gold-plated brass GND Orange White/Green Green 5 White/Brown 6 Brown 7 White/Blue 8 Blue GND Cable Type Shielded teal PUR, twisted pairs, 6 AWG, Industrial Cat 6, sun light and oil resistant Nominal Outer Diameter 5.8 mm (0. in.) ±0% Connector pin assignment plug M Cat 6 pin side view A Bend Radius 0 x cable diameter Cable Rating Shielded: Standard TIA 568-B, ISO/IEC 80, flex-rated, 6 AWG, halogen-free, Type CMX 5 6 Enclosure Type Rating IP67 Operating Temperature C ( F) 7 8 Figure 9 - Cordsets/Patchcords 50 (.97) Example of M to M Patchcord Example of M to RJ5 Patchcord Rockwell Automation Publication 585-TD00D-EN-P - April 07
13 M Red Attributes Bulletin 585D Coupling Nut Material Nickel-plated brass Housing Material Polyurethane (PUR) Contact Material Gold-plated brass Nominal Outer Diameter 5.8 mm (0. in.) ±0% Enclosure Type Rating IP67 Bend Radius 0 x cable diameter -Pin M D-Code Cordset Pinout Face View Pinout Face View RJ5 Pinout -Pin Face View RJ5 Pinout 8-Pin Color Code Pin -Pin A White-Orange White-Green Orange Green Orange White/Green Blue 5 White/Blue 6 Green 7 White/Brown 8 Brown TxData + TxData - Recv Data + Recv Data - Orange White/Green 5 6 Green 7 8 TxData + TxData - Recv Data + Recv Data - Figure 0 - Cordsets/Patchcords 7 (.85) Example of M to M Patchcord Example of Cordset Example of M to RJ5 Patchcord Rockwell Automation Publication 585-TD00D-EN-P - April 07
14 Patchcords and Field Attachable Die-cast Zinc RJ5 Connector, Variant Attributes Bulletin 585BX and 585BZ Certifications UL Listed and c-ul Contact Material Copper alloy Housing Material Die-cast zinc Cable Diameter mm ( in.) Cable Rating 6 AWG, mm ( in.) Assembly Rating 50V,.5 A Mating Cycles 750 Voltage 00V Enclosure Type Rating IP67 Operating Temperature C ( F) Figure - Die-cast Zinc RJ5 Connector, Variant Dimensions Variant Connector -White/Orange -Orange -White/Green -Blue 5. (6.0) 5-White/Blue 6-Green 7-White/Brown 8-Brown 0 (.8) 60. (.7) 0 (.8) Dia. 0 (0.79) Dia. Figure - Male Housing 78.7 (.) 0. (0.79) 0. (.) Dia. 0. (0.79) For color coding ring Rockwell Automation Publication 585-TD00D-EN-P - April 07
15 Figure - Female Receptacle.6 (.0) Dia. 0. (.) 0.0 (.8) 7. (.9) 0. (.) Figure - Female Receptacle 5. (.).6 (.0) Dia..0 (.) 0.0 (.8).0 (.) Rockwell Automation Publication 585-TD00D-EN-P - April 07 5
16 Thermoplastic RJ5 Connector, Variant Attributes Bulletin 585BP and 585BT Certifications UL Listed and c-ul Contact Material Copper alloy Housing Material Polybutylene teraphthalate (PBT) Cable Diameter mm ( in.) Cable Rating 6 AWG, mm ( in.) Assembly Rating 50V,.5 A Voltage 00V Mating Cycles 750 Enclosure Type Rating IP66, IP67, NEMA 6 Operating Temperature C (- +67 F) Figure 5 - Thermoplastic RJ5 Connector, Variant Dimensions Variant Connector -White/Orange -Orange -White/Green -Blue 5. (6.0) 5-White/Blue 6-Green 7-White/Brown 8-Brown 0 (.8) 60. (.7) 0 (.8) Dia. 0 (0.79) Dia. Figure 6 - Male Housing 0. (.9) dia.. (.8) Acceptable Cable ( ) dia. UTP. Symbol (0.8).9 (.) 5.7 (.) 6 Rockwell Automation Publication 585-TD00D-EN-P - April 07
17 Figure 7 - Female Receptacle Thread -/6 x 8 UNF 0 (.8) RJ5 Outlet per IEC (0.97) (.) dia. (0.5) 7 (0.67) (.) Figure 8 - Female to Female Coupler 7.7 (.09) 5.8 (.) 0 (.8) Thread -/6 x 8 UNF. (0.). Max. (0.) Panel Thickness. (.75) Rockwell Automation Publication 585-TD00D-EN-P - April 07 7
18 Field Attachable RJ5 Connector Features IDC Connector Crimp Connector 6 AWG Conductors 6 AWG 60 shielding Standard crimp connector with rugged boot Reuse IDC connector up to five times Cat 5e No tools or conductor stripping required Cat 6 RJ5 Insulation Displacement Connector (IDC) RJ5 Crimp Attribute Certifications Connector Type Enclosure Type Rating Operating Temperature Bulletin 585J UL Listed RJ5 male IP C ( F) Pinout Face View RJ5 Pinout 8-Pin Color Code Pin -Pin A Orange White/Green Blue 5 White/Blue 6 Green 7 White/Brown 8 Brown TxData + TxData - Recv Data + Recv Data - Orange White/Green 5 6 Green 7 8 TxData + TxData - Recv Data + Recv Data - 8 Rockwell Automation Publication 585-TD00D-EN-P - April 07
19 Figure 9 - RJ5 Insulation Displacement Connector (IDC).9 (0.50).6 (0.6).6 (0.57) 6.6 (0.6) 9. (0.7) 5. (.0) Figure 0 - RJ5 Crimp Connector 8.6 (0.) 5.7 (.).68 (0.6) 8.8 (0.).8 (0.7) 7.7 (0.9) 6.60 (0.6).55 (0.89). (0.8) 7.9 (0.) 9.7 (0.8).5 (0.5) 8.6 (0.6) 6.0 (0.) 6.5 (0.6) Rockwell Automation Publication 585-TD00D-EN-P - April 07 9
20 M Insulation Displacement Connectors (IDC) Features Field installable with no hand tools needed Straight male or female shielded versions Allows easy modification of existing cable installations Insulation displacement technology for secure installation with excellent reliability Metal body unit excellent in shielding applications Field Attachable Attribute Coupling Nut Material Connector Shell Material Contact Material IDC Installations Conductor OD Assembly Rating Enclosure Type Rating Operating Temperature Installation Temperature Bulletin 585D Zinc die-cast Zinc die-cast or polyamide Gold-plated brass 0x, max. Unshielded: 6 AWG:.0.6 mm ( in.); Shielded: AWG:..6 mm ( in.) V, A IP C (- +85 F) C ( 85 F) Pinout Face View Pinout Face View M Pinout -Pin Color Code A White-Orange White-Green Orange Green 0 Rockwell Automation Publication 585-TD00D-EN-P - April 07
21 Figure - M Insulation Displacement Connectors Dimensions 5 (0.60) 0 (0.75) Complete length when assembled approx..5 (.7) M x Coupling Nut Connector Body O-Ring 5. (0.60) Dia. Wire Gauge Cable Stop Compression Ring Connector Shell Figure A 5.7 (.0) 7.8 (.88) 9.5 (0.76) Dia. M x SW Across flats 9.5 (0.76) M x Dia. SW Across flats Male SW7 Across flats Figure B SW7 Across flats Female Rockwell Automation Publication 585-TD00D-EN-P - April 07
22 M to RJ5 Bulkhead Connector Attributes Certifications Receptacle Shell Material Contact Material Wire Insulation Assembly Rating Enclosure Type Rating Operating Temperature Bulletin 585A UL Recognized for Canada and USA Nickel-plated brass Brass with nickel plating Oil-resistant PVC, AWG stranded copper, 00V, UL recognized V, A IP67, 00 psi (870 kpa) washdown C (- +85 F) Field Attachable Figure - M to RJ5 Bulkhead Connector Dimensions 5 (0.59) SW 0 Across Flats.6 (0.85) Shielding from housing over PCB to RJ5 6.5 (0.65) Dia. 5. (0.6) Panel Cut Out M 00Ω 00Ω RJ (0.87) M6 x.5 Nut O Ring M x 8.9 (.) 6. (.8) Rockwell Automation Publication 585-TD00D-EN-P - April 07
23 Notes: Rockwell Automation Publication 585-TD00D-EN-P - April 07
24 Rockwell Automation Support Use the following resources to access support information. Technical Support Center Local Technical Support Phone Numbers Direct Dial Codes Literature Library Product Compatibility and Download Center (PCDC) Knowledgebase Articles, How-to Videos, FAQs, Chat, User Forums, and Product Notification Updates. Locate the phone number for your country. Find the Direct Dial Code for your product. Use the code to route your call directly to a technical support engineer. Installation Instructions, Manuals, Brochures, and Technical Data. Get help determining how products interact, check features and capabilities, and find associated firmware Documentation Feedback Your comments will help us serve your documentation needs better. If you have any suggestions on how to improve this document, complete the How Are We Doing? form at Rockwell Automation maintains current product environmental information on its website at Allen-Bradley, Armor, LISTEN. THINK. SOLVE., On-Machine, Rockwell Automation, Rockwell Software are trademarks of Rockwell Automation, Inc. ControlNet, DeviceNet, and EtherNet/IP are trademarks of ODVA, Inc. Trademarks not belonging to Rockwell Automation are property of their respective companies. Rockwell Otomasyon Ticaret A.Ş., Kar Plaza İş Merkezi E Blok Kat:6 75 İçerenköy, İstanbul, Tel: +90 (6) Publication 585-TD00D-EN-P - April 07 Supersedes Publication 585-TD00C-EN-P - April 06 Copyright 07 Rockwell Automation, Inc. All rights reserved. Printed in the U.S.A.
Ethernet Media. Technical Data. Cable Spools 2. Cordsets & Patchcords 5. Patchcords & Field Attachables 12
Technical Data Ethernet Media Bulletin Numbers 585, 585A, 585BP, 585BT, 585BX, 585BZ, 585D, 585J Topic Page Cable Spools Cordsets & Patchcords 5 Patchcords & Field Attachables Cable Spools Unshielded Twisted
More informationEthernet Media. Technical Data. Cable Spools 2. Cordsets & Patchcords 5. Patchcords & Field Attachables 10
Technical Data Ethernet Media Bulletin Numbers 585, 585A, 585BP, 585BT, 585BX, 585BZ, 585D, 585J Topic Page Cable Spools Cordsets & Patchcords 5 Patchcords & Field Attachables 0 Cable Spools Unshielded
More informationContents 9-1. Network Media
Contents General Information Quick Selection Guide... page 9--2 Introduction... page 9--3 Ethernet Media Cordsets & Patchcords Cable Spools... page 9--4 Cordsets & Patchcords... page 9--5 Field Attachable
More informationEthernet Media. Introduction Quick Selection Ethernet Media. Systems. PannelConnect Connection. Connection. Safety.
Table of Contents Guide...7-2...7-3 Unshielded Twisted Pair...7-5 Shielded Twisted Pair...7-6 600V Ethernet Cable...7-7 Cordsets & Patchcords RJ45...7-9 M12 Flex-Rated...7-10 M12 Receptacle Flex-Rated...7-12
More informationEthernet Media. Introduction Quick Selection Ethernet Media. Systems. PannelConnect Connection. Connection. Safety.
Table of Contents Ethernet Quick Selection Guide...7-2...7-3 Cable Spools Unshielded Twisted Pair...7-5 Shielded Twisted Pair...7-6 600V Ethernet Cable...7-7 Cordsets & Patchcords RJ45...7-9 M12 Flex-Rated...7-10
More information10 million cycles at 20 x diameter (TPE cable)
Unshielded Twisted Pair Unshielded Ethernet Cable Spool robust thermoplastic elastomer (TPE) jacket, data is protected from noise, chemicals, and mechanical issues to Two and four pair TPE robotic flex
More information10 million cycles at 20 x diameter (TPE cable)
Ethernet Media Cable Spools Unshielded Twisted Pair Unshielded Spool Rockwell Automation s Cat5e shielded and unshielded cable is designed to supply a reliable network connection in harsh surroundings.
More information10 million cycles at 20 x diameter (TPE cable)
Ethernet Media Cable Spools Unshielded Twisted Pair Unshielded Spool Rockwell Automation s Cat5e shielded and unshielded cable is designed to supply a reliable network connection in harsh surroundings.
More informationIndustrial Ethernet Media
Industrial Ethernet Media Complete Solution for Ethernet Networks and Integrated Architecture PRODUCT SPOTLIGHT Ethernet networking is a growing solution for industry applications, and Rockwell Aumation
More informationBUS UNITRONIC BUS DeviceNet Gray
BUS UNITRONIC BUS DeviceNet Gray For DeviceNet bus systems; stationary applications; UNITRONIC UNITRONIC DeviceNet THIN UNITRONIC BUS DeviceNet cables provide reliable data and power transfer between industrial
More informationPowerMonitor 5000 USB Driver
Installation Instructions Original Instructions PowerMonitor 5000 USB Driver Bulletin Number 1426 Topic Page Overview 1 Summary of Changes 2 Download the USB Driver 2 Install Drivers 7 Configure the Connection
More informationFork Sensors. Technical Data. Plastic Fork Sensors
Technical Data Fork Sensors Catalog Numbers 5LSP2LNAP, 5LSP2LPAP, 5LSP2LNA2P, 5LSP2LPA2P, 5LSP2LNAP, 5LSP2LPAP, 5LSP2LNAP, 5LSP2LPAP, 5LSTLEAP, 5LSTLEA2P, 5LSTLEAP, 5LSTLEAP, 5LSTLEA5P, 5LSTLEA6P, 5LSTLEA7P
More informationEthernet Series. Etherplug Etherlink V Etherlink V Specifications Ethernet Series
Etherplug... 10-113 Etherlink V3...114-116 Etherlink V1... 117-120 Specifications..121-122 107 Mencom Corporation TEL: 770-534-455 www.mencom.com Etherplug Cordsets PVC & PUR Cable Pole PVC Version of
More informationAC Micro Style Cordsets and Receptacles
AC Micro Style Cordsets and Receptacles Description Rockwell Automation/Allen-Bradley offers a wide variety of connection products for interfacing field devices to I/O, junction boxes, PLCs, etc. Connection
More informationM12 connector D-coding M12 connector X-coding RJ45 IP20 connector PushPull RJ45 IP65 / IP67 connector
M12 connectors Directory Chapter Page General information....02 M12 connector D-coding....06 M12 connector X-coding....20 RJ45 IP20 connector....27 PushPull RJ45 IP65 / IP67 connector....46 Han 3 A RJ45
More informationARMORSTART POWER MEDIA SYSTEM QUICK REFERENCE GUIDE COLLECTION :
ARMORSTART POWER MEDIA SYSTEM QUICK REFERENCE GUIDE COLLECTION : Single page documents providing comprehensive system examples of the cable assemblies for ArmorStart, ArmorStart ST, ArmorStart LT, and
More informationCONEC Industrial Ethernet Circular Sealed RJ45 Connector System consists of a RJ45 Plug Kit, a Receptacle Kit and a Protective Cover Assembly.
Revised Sept-28-2009 Sealed Industrial Ethernet Circular IP67 Cat. 5e RJ45 Connector System Instructions CONEC Industrial Ethernet Circular Sealed RJ45 Connector System consists of a RJ45 Plug Kit, a Kit
More informationNever Beaten by Seasons
Never Beaten by Seasons Buccaneer For Data Frozen Winters! Torrential Springs! Blistering Summers! Dusty Autumns! The Buccaneer range of IP68 waterproof connectors for Ethernet, USB, Mini USB and FireWire.
More informationµcom-10gb + MAIN FEATURES FEATURES AND BENEFITS MARKETS & APPLICATIONS Harsh Environment 10Gb Ethernet Micro Connectors Amphenol Socapex
Harsh Environment 10Gb Ethernet Micro Connectors 15mm µcom-series is a new range of connectors designed to address the latest trends of the industry : miniaturization and high speed, with the highest resistance
More information07. har-link Interface Connectors
. Interface Connectors The highest data rates in combination with perfect shielding characterize the connector. This way data can be passed on optimally within the control cabinet. The locking mechanism
More informationComplete the Installation SKINTOP MS-SC. Color Code: Approvals: Nominal Outer Diameter
BUS UNITRONIC BUS PB For PROFIBUS-DP/FMS/FIP bus systems; stationary applications; 150 Ω UNITRONIC BUS PB UNITRONIC BUS PB FC UNITRONIC BUS PROFIBUS cables are designed for automation networks requiring
More informationComplete the Installation SKINTOP MS-SC. Approvals: Approx. SKINTOP Part
ETHERLINE HEAT 6722 Flexible special Ethernet cable for high-temperature applications ETHERLINE HEAT 6722 ETHERLINE HEAT 6722 ETHERLINE HEAT 6722 Insulation: polyolefin wrapped with special fire-retardant
More information6000 Series Buccaneer
Robust, instant connections for harsh environments 6000 Series Buccaneer - circular connectors that combine the ease of use of a push/pull coupling mechanism with proven environmental sealing. Available
More informationBetter all-round. DataVoice Circular connectors STX M12x1 IP67 Connector series for industrial applications. PoE+ 10 GBE. coded.
Better all-round. X coded D coded 10 GBE PoE+ DataVoice Circular connectors STX M12x1 IP67 Connector series for industrial applications STX M12x1 IP67 connector series With the STX M12x1 IP67 connector
More informationµcom-10gb + Amphenol MAIN FEATURES FEATURES AND BENEFITS MARKETS & APPLICATIONS Harsh Environment 10Gb Ethernet Micro Connectors
Harsh Environment 10Gb Ethernet Micro Connectors 15mm µcom-series is a new range of connectors designed to address the latest trends of the industry : miniaturization and high speed, with the highest resistance
More informationPHOTOSWITCH Distance Measurement Sensor
Installation Instructions Original Instructions Catalog Numbers 45DMS-B8LAT-D4, 45DMS-B8LGT-D5 Topic Description Save these instructions for future use. Description Features Sensor Configuration Precision
More informationIP68 Sealed - Mini USB Buccaneer
IP68 Sealed - IP68 Over moulded assembly provides IP68 cable seal Coupling ring, screw thread provides secure cable coupling Mini USB connector O ring maintains IP68 seal at connector interface Mini USB
More informationDeviceNet Media System
System Table of Contents General Information Quick Selection Guide...6-...6- Flat System KwikLink Lite...6-6 Cable Spools...6-7 Trunk-Line Connector, Drop-Line Connector, and Flat to Thin Round Converter,
More informationStandard Buccaneer - Ethernet
IP6 rated IP69K, Tested in accordance with DIN 40050/Part 9 IP6k9k or compliant PUR / PVC jacket on cable Shielded system or shielded coupler Shroud on RJ45 Screw coupling Rewireable flex connector PCB
More informationEPIC Circular Connectors CIRCON M23 Series
The M3 connectors have many inherent features which offer application advantages and provide significant benefits for the customer. These features make it one of the most application friendly connectors
More informationCC-Link. Simple communication programming - configuration software available but not required
(Control & Communication Link) is a field network system that processes control and information data at high speed while ensuring a deterministic response. Features include: Simple communication programming
More informationCat.8 Shielded Field Termination Plug Description
Description RiT s CAT8 Shielded field termination plug are cost-effective building blocks for your cabling system. Meticulously engineered to deliver exceptional performance while streamlining installations.
More informationInView Communication Modules
Installation Instructions InView Communication Modules Catalog Numbers 2706-PxM, 2706-PxK, 2706-PxP Topic Page About This Publication 1 Important User Information 2 Power Supply Requirements 3 Mount the
More informationArmorConnect Power and Control Media
Selection Guide ArmorConnect Power and Control Media Bulletins 280, 888, 889, 898 2 Bulletin 280, 888, 889, 898 Power Media Product Overview Media Description Features Trunk Cable Cordset - Cable with
More informationSensor Connectivity Introduction Global Plus Connector Cables Multi-Connector Blocks. Product Selection Guide...
.0 Introduction Product Selection Guide.................................... Product Description....................................... Standards and Certifications................................ Product
More informationIDC Field Wireable eurofast & picofast Connectors
Advanced Connection Solutions for Manufacturers Worldwide! IDC Field Wireable eurofast & picofast Connectors picofast Field Wireable IDC Connector eurofast Field Wireable IDC Connector Overview Connection
More informationIndustrial Ethernet Panel-Mount Adaptors for PROFINET or EtherNet/IP Applications
Industrial Ethernet Panel-Mount Adaptors for PROFINET or EtherNet/IP Applications Type 0981 ENC 100 RJ45/M12 adaptor, female receptacle connector M12, D coding, chassis side thread PG 9, RJ45 female connector,
More informationEtherNet Physical Media Connectivity
Part Number Keys Cordsets Receptacles EtherNet/IP Cordsets Field Wireables K3 K6 K13 K16 K24 EtherNet Features CAT 5E rated cables 2 pair and 4 pair cable option 8-pin and 4-pin D-coded connectors M12
More informationEthernet cabling. B Ethernet cabling. Ethernet cabling overview B 2. Cabling 4-poles IP 20 B.1 8 IP 65 / IP 67 B Cables B Tools B.
Ethernet cabling Contents Page B Ethernet cabling Ethernet cabling overview B 2 Cabling 4-poles B.1 8 B.1 22 Cables B.1 96 Tools B.1 104 Cabling 8-poles B.2 8 B.2 20 Cables B.2 90 Tools B.2 98 B 1 Profile
More informationNew Product Bulletin. Lumberg Automation EtherNet/IP Modules for Industrial Automation Applications
New Product Bulletin PB 327 Lumberg Automation EtherNet/IP Modules for Industrial Automation Applications These 16 digital I/O channels with universal input/output functionality for direct connections
More informationEPIC LS1 Series Circular Power & Mixed Power Connectors
EPIC LS1 Series Circular Power & Mixed Power Connectors EPIC LS1 Circular and Mixed Power Connectors are designed to DIN specification EN61984 and have a standard M23 threaded connection housing. They
More informationStandard Buccaneer - Ethernet
IP6 rated IP69K, Tested in accordance with DIN 40050/Part 9 IP6k9k or compliant PUR / PVC jacket on cable Shielded system or shielded coupler Shroud on RJ45 Screw coupling Rewireable flex connector PCB
More informationData sheet C6 A modul 90 jack
Illustrations Dimensional drawing Cut-out Page 1/7 See enlarged drawings at the end of document Product specification modular Cat.6 A termination unit RJ45 mounting version: module, 90 cable feed solid,
More information9/27/04 cci Cablecom Inc. 1
cci Cablecom Inc. 1 CCI Cablecom Inc. is a privately held, women owned corporation headquartered in Aurora, CO. We manufacture a variety of voice and datacom products. Cable applications Include: Local
More informationPanelView Plus to PanelView Plus 6 Catalog Number Conversions
Migration Guide PanelView Plus to PanelView Plus 6 Topic Page About This Publication 1 Platform Comparisons 3 Windows CE 6.0 Operating System 4 PanelView Plus 6-400 and 600 Terminal Selections 5 Catalog
More informationPanelView 5510 Terminal Specifications
Technical Data PanelView 5510 Terminal Specifications Catalog Numbers 2715P-B7CD, 2715P-B7CD-B, 2715P-T7CD, 2715P-T7CD-B, 2715P-T7WD, 2715P-T7WD-B, 2715P-T9WD, 2715P-T9WD-B, 2715P-B10CD, 2715P-B10CD-B,
More informationData sheet. Connection line M12 8-pole X-coded 2.0 m. Illustrations P/N 142M2X11020 EAN Product specification. Page 1/
Page 1/5 Illustrations Dimensional drawing See enlarged drawings at the end of document Product specification shielded M12 Ethernet connection line Cat.6A, 8 pole, X-coded M12 connector, straight on M12
More informationData sheet C6 A modul 1 port 180 M AP pure white
Illustrations Dimensional drawing Page 1/7 See enlarged drawings at the end of document Product specification surface-mount termination unit with C6modul 180 certified to GHMT Cat.6 re-embedded PVP component
More informationFISCHER MINIMAX TM SERIES
TECHNICAL SPECIFICATIONS FISCHER TM SERIES Fischer Connectors SA All rights reserved Web version 1.0-03.2016 Changes without prior notice FISCHER TM SERIES KEY FEATURES The Fischer MiniMax Series increases
More informationEN3 SERIES WEATHERTIGHT CONNECTORS NEW PRODUCT BULLETIN 602
FEATURES & BENEFITS Sealed to IP68 NEMA 250 (6P) Patented grommet & o-ring free design Available in ribbed or winged coupling ring Cable, panel & cable to cable options Gold plated contacts standard Solder,
More informationRS-232 Connector Pin Assignments
APPENDIXB This appendix lists the connector pin assignments for the CDEs, and includes the following sections: Serial Console-Interface, page B- Ethernet, page B- Cable Pin Assignments, page B- Serial
More information6000 Series Buccaneer. 30 twist locking Tamperproof lock prevents accidental un-mating. Cat 5e shielded coupler Maintains shielding
circular connectors that combine the ease of use of a push/pull coupling mechanism with proven environmental sealing. Available with metal or plastic bodies, the range supports both data (USB and Ethernet),
More informationControl Tower Stack Lights
Selection Guide Control Tower Stack Lights Bulletin Numbers 854J, 854K Control Tower Stack Lights What s Inside Topic Page Bulletin 854J - 40 mm Control Tower Stack Lights Product Overview 3 Product Selection
More informationM12 Field Wireable Connectors. M12 CAT.6A Field Wireable Connectors. M12 Field Wireable Connectors for PROFINET
M12 Connectors Application Advantage Shielded design ETHERLINE Ethernet Cable, Connectors & Tools M12 Field Wireable Connectors Male Female Temperature Range: Max. 85 C Nominal Voltage: Nominal Current:
More informationUSB Buccaneer BUCCANEER
Over moulded assembly provides IP68 cable seal Coupling ring, screw thread provides secure cable coupling USB adaptor Sealing Cap Clip Standard USB O ring maintains IP68 seal at interface Panel gasket
More informationDisconnect Switch and Circuit Breaker Mechanism Specifications Bulletin Number 1494
Technical Data Disconnect Switch and Circuit Breaker Mechanism Specifications Bulletin Number 1494 Topic Page 1494U Disconnect Switch Specifications 2 1494C, 1494F, 1494G, 1494R, 1494V Disconnect Switch
More informationHan-Brid. Contents Han-Brid Features Han-Brid Data interfaces Han-Brid Overview Han-Brid Cu
Contents Page Features... 19.02 Data interfaces... 19.03 Overview... 19.04 Cu... 19.06 F.O.... 19.08 Quintax 3 A... 19.10 RJ45 C... 19.12 USB / FireWire... 19.14 Han 4 A SC... 19.16 Hoods/Housings... 19.18
More informationM23 Connectors and cables
Contents Product Description: SAI M23 Connectors.2 Contact assignment.7 Technical data.8 Overview.10 M23 connector for signal transmission.12 M23 connector for power transmission.18 Moulded M23 cables.22
More information1756 ControlLogix Chassis Specifications
Technical Data 1756 ControlLogix Chassis Specifications Catalog Numbers 1756-A4/B, 1756-A7/B, 1756-A10/B, 1756-A13/B, 1756-A17/B, 1756-A4LXT, 1756-A5XT, 1756-A7LXT, 1756-A7XT Topic Page Standard ControlLogix
More information400 Series - Mini USB Buccaneer
IP68 Sealed IP68 rated IP69K, Tested in accordance with DIN 40050/Part 9 IP6k9k USB V2.0 performance Plug and play capability Shielded system Overmoulded cables Screw coupling PCB versions Dust and waterproof
More information07. har-link INTERFACE CONNECTORS
. INTERFACE CONNECTORS The highest data rates in combination with perfect shielding characterize the connector. This way data can be passed on optimally within the control cabinet. The locking mechanism
More informationPowerFlex 755 Common DC Input Drives, Frames Interlock Assembly and Precharge Assembly Left-front Cover Retrofit Kit
Installation Instructions PowerFlex 755 Common DC Input Drives, Frames 8...10 Interlock Assembly and Precharge Assembly Left-front Cover Retrofit Kit Catalog Numbers 20G14x, 21G14x Topic Page General Precautions
More informationPRODUCT INFORMATION. ETHERLINE Cat.5e FLEX. Info Industrial Ethernet cable Cat.5e Only for patch cable applications (max. 60 m)
Ethernet cable Category 5e, Class D for flexible use - verified up to 100 MHz Industrial Ethernet cable Cat.5e for flexible use halogenfree or PUR (AWM-approval) outer sheath material, design 2 or 4 x2xawg26/7
More informationLP-4CEUSXX Cat 5e Unshielded U/UTP Patch Cords
Cabling - Copper Solutions LP-4CEUSXX Cat 5e Unshielded U/UTP Patch Cords LP4CEUSXX_SS_ENB01W Features Unshielded snagless U/UTP Patch Cords. UL, CSA approved. ETL verified. Cat 5e patch cords are backward
More informationODU MINI-SNAP PC Product Description. ODU MINI-SNAP PC: The Connector with Push-Pull-Locking in Plastic
ODU MINI-SNAP PC Product Description ODU MINI-SNAP PC: The Connector with Push-Pull-Locking in Plastic Cylindrical Connectors are generally available with several locking mechanisms: The most frequently
More information1/2 microfast Connectivity
Part Number Keys Cordsets Receptacles Field Wireables Adapters E2 E4 E8 E16 E17 microfast Features y 2 to 6 pin y Up to 4 Amp, 250 Volt rated y IEC IP67 protection y NEMA 6P rated y Low current AC applications
More informationAMP NETCONNECT EtherSeal System Bringing Ethernet and Structured Cabling to Non-Office Environments.
EtherSeal System Bringing Ethernet and Structured Cabling to Non-Office Environments. From the factory floor to the hospital room, Ethernet is the network type of choice. More and more TCP/IP applications
More information07. har-link Interface Connectors
. Interface Connectors The highest data rates in combination with perfect shielding characterize the connector. This way data can be passed on optimally within the control cabinet. The locking mechanism
More informationD-Series High Reliability Circular Connectors
D-Series High Reliability Circular Connectors Technology Company, Inc. integramate D-Series Circular Connectors QA Technology integramate D-Series Connectors are high quality, plastic circular connectors
More informationRJF RB Ethernet connection system for harsh environment Industrial Ethernet
RJF RB Ethernet connection system for harsh environment Industrial Ethernet ROHS compliant RJFRB allows you to use an Ethernet Class D / Cat 5e and Class E / Cat 6 connection for 10 BaseT, 100 BaseTX or
More informationStarter and Circuit Breaker Application with PowerFlex 7000
Application Technique Starter and Circuit Breaker Application with PowerFlex 7000 Bulletins 7000A, 7000, 7000L Topic Page General Precautions 2 Document Scope 2 Purpose 3 Drive Associated MV Starters and
More informationHan R 23. Circular Connector. Certified acc. to DIN EN ISO 9001 in design/ development, production, installation and servicing.
Circular Connector Certified acc to DIN EN ISO 9001 in design/ development, production, installation and servicing Data Sheet 0039-4 Circular Connectors Features Size R 23 Outer diameter 26 mm High contact
More informationCat.8 Shielded Keystone Jack Description
Description RiT s CAT8 Shielded Keystone Jacks are cost-effective building blocks for your cabling system. Meticulously engineered to deliver exceptional performance while streamlining installations. Phosphor
More informationRugged USB Solutions USB3.0
Rugged USB Solutions USB3.0 NEW table of contents NEW USB3.0 Field installable USB3FTV (USB-A)... 88 USB3F TV - Transversally sealed receptacles... 92 USB3F TV - Hermetic receptacles... 95 USB3 receptacle
More informationData sheet. 25Gmodul. Illustrations P/N 130B11-25-E EAN Product specification. Page 1/ Dimensional drawing
Page 1/6 Illustrations Dimensional drawing Cut-out See enlarged drawings at the end of document Product specification certified by GHMT according to DTR-11801-9905 for 25GBASE-T in the Channel-Link with
More informationModular plugs, accessories and tooling
Modular plugs, accessories and tooling Introducing the new Cat 6A/6 modular plugs, slim-line boots and color clips CommScope modular plug portfolio CommScope offers a vast portfolio of Modular Plugs for
More informationPowerMonitor 1000 Unit Catalog Number Upgrade
Installation Instructions PowerMonitor 1000 Unit Catalog Number Upgrade Catalog Numbers 1408-UPT1-E3, 1408-UPT2-E3, 1408-UPE1-E3, 1408-UPE2-E3, 1408-UP485-ENT, 1408-UPT3-E3 Topic Important User Information
More informationPanelView Plus 7 Standard Terminals
Technical Data PanelView Plus 7 Standard Terminals Catalog Numbers 2711P-T4W21D8S, 2711P-T4W22D8S, 2711P-T4W21D8S-B, 2711P-T4W22D8S-B, 2711P-T6C21D8S, 2711P-T6C22D8S, 2711P-T6C21D8S-B, 2711P-T6C22D8S-B,
More information0.703 dia. [17.86] Cord Connector Contact Arrangements Shown from rear of connector DIMENSIONS ARE FOR REFERENCE ONLY
ONLINE CATALOG SWITCHCRAFT, INC. N. Elston Ave. Chicago, IL 00 77 79-700 FAX: 77 79-19 www.switchcraft.com EN MINI WEATHERTIGHT CONNECTOR SERIES EN CORD CONNECTOR 1.8 [9.8] 0. REF 0.70 dia. [17.8] PIN
More informationType Qty. Order No. IE-PI-HYB-10P
IP67 plug-in connector Hybrid plug inserts Cat.5 IP 20 For Variant 1, 4 and 14 housings Crimp Passive components C Category Degree of protection Plugging cycles Shielding Housing main material Wire cross-section,
More information6000 Series Buccaneer
Robust, instant connections for harsh environments 6000 Series Buccaneer - circular connectors that combine the ease of use of a push/pull coupling mechanism with proven environmental sealing. Available
More information4Cu-LSA Connection technology
4Cu-LSA technology LSA- technology: Patch panels, Telephone Patch Panels, RJ45, Tera, Office-Patch Panels, Data outlets, surface mounting, flush mount, underfloor, 60 Table of Contents Office DC FTTX Patch
More informationCX BD series. Main features MULTIPOLE CONNECTORS CX BD CN
MULTIPOLE CONNECTORS CX BD CN i CX BD series Main features To be able to use round shielded connectors series MIXO BUS (multiaxial, for balanced cables with multiple pairs) or coaxial connectors (for coaxial
More informationM12x1 Circular Connectors
M12x1 Circular Connectors Agenda 1. Introduction M12x1 Circular Connectors 2. M12x1 X-coded 3. M12x1 D-coded 4. Accessories and Nomenclature 3 / 2015 Product Presentation M12x1 Page 2 M12x1 Circular Connectors
More informationData sheet C6 A modul 2 port 180 M UP pure white
Illustrations Dimensional drawing Page 1/7 See enlarged drawings at the end of document Product specification flush-mounted termination unit with C6 A modul 180 certified to GHMT Cat.6 A re-embedded PVP
More informationTECHNICAL DATA SHEET Family code C2424SOLPCORD CAT 6 UTP Solid. version 1 LSNH PATCHCORD date page 1/5
page 1/5 Application: High Density Switch & Hub Working area cord and telecommunications equipment cord in Local Area Networking environments Support current and future Category 6 applications, such as:
More informationOperating voltages up to 40 kvdc Operating current up to 30 Amps Advanced contact technology Silver plated and gold plated contacts available High
Operating voltages up to 40 kvdc Operating current up to 30 Amps Advanced contact technology Silver plated and contacts available High performance insulation material General characteristics and technical
More informationD-Sub SEaled subminiature D connectors, 2.54 mm pitch
SE D-Sub SEaled subminiature D connectors, 2.54 mm pitch Page Technical characteristics.......................................... 02 IP 67 versions with turned solder cups......... 04 IP 67 versions with
More informationÖLFLEX CONNECT. Systems solutions made by Lapp 597 ÖLFLEX CONNECT CABLES 599 ÖLFLEX CONNECT SERVO 609 ÖLFLEX CONNECT CHAIN
Systems solutions made by Lapp 597 CABLES 599 SERVO 609 CHAIN 612 Industrial Ethernet & Fieldbus Cordsets 630 Remote Access Ports 595 Systems solutions made by Lapp CABLES 597 CABLES 598 Custom Assembly
More information11 PROFIBUS Fieldbus Connector
750-960 PROFIBUS Fieldbus Connector 634 54 mm> < < 45mm 5 < 36,7mm < 372 mm < 54 mm < 36 mm / 42 in < 5-6 mm / 022 in < 0 mm / 0394 in The fieldbus connector links a PROFIBUS device
More informationConnecting cables, Ethernet Technical data
Connecting cable NEBC-D12G4 Connecting cable M12 4-pin D-coded Cable lengths 0.5 10 m Suitable for Ethernet General technical data Electrical connection connector, 4-pin,, D-coded connector, RJ45, 8-pin
More informationConnection Systems Table of. Contents. Safety Switches. Operator. Interface. Logic. Power. Connection Systems Table of Contents
Table of Contents Connection Systems Overview...7-7-Table of Contents Safety Wiring Systems Safety Wired T-Port, DC Micro...7-6 Safety Wired Distribution Box, DC Micro...7-7 Safety Wired Distribution Box,
More informationField-terminated RJ45 connector with housing. Color housing: gray (RAL 7042). Color termination block: red.
FM45 Connector Cat. 6 A IP20, 4P, TIA 568-A/B, 10x R815651 966704105 10 Stk. 090.7437 / ähnliche Abbildung Instruction manual Field-terminated connector with housing. Color housing: gray (RAL 7042). Color
More informationfischer connectors 4032 Series HIGH-PERFORMANCE IN A VERSATILE PACKAGE MEDICAL PORTABLE EQUIPMENT DATA ACQUISITION INSTRUMENTATION Edition 1.
fischer connectors 4032 Series Plastic connectors Edition 1.2 MEDICAL PORTABLE EQUIPMENT DATA ACQUISITION HIGH-PERFORMANCE IN A VERSATILE PACKAGE INSTRUMENTATION PERFECT PACKAGE www.fischerconnectors.com
More informationInnovative system solutions flexible connection technology
426 Innovative system solutions flexible connection technology Systems for direct Ethernet device connection 1 Direct PC Board Connection 433 2 IP67 Protected Connectors Variant 1 436 3 IP67 Protected
More informationStandard Buccaneer BUCCANEER FOR POWER
IP8 rating tested at 1.05kg/sq cm (15lb/sq in) 10m depth for weeks and.8kg/sq cm (10lb/sq in) 100m depth for hours IPK, Tested in accordance with DIN 0050/Part IPkk Water and dustproof to IP8 when mated,,,,,,
More informationPA Physical Media Connectivity
PROFIBUS Cordsets Receptacles Terminating resistors Tees Field Wireables P24 P21 P28 P30 P34 Features Cable that meets the requirements of ISA/SP 50 and PROFIBUS-PA requirements for Type A Cable All cables
More informationRTX series EN
RTX series EN3716 10 CONTENTS RTX series Page RTX series Introduction... 10-4 Applications... 10-4 Product overview... 10-5 Technical characteristics... 10-6 & 10-7 How to order connectors... 10-8 Dimensions
More informationRJF TV Ethernet Connection System for Harsh Environment
RJF TV Ethernet Connection System for Harsh Environment ROHS compliant N & BZ RJFTV allows you to use an Ethernet Class D / Cat. 5e connection for 10 BaseT, 100 BaseTx or 1000 BaseT networks in harsh environments.
More informationpicofast 4 - Branch Molded Junctions, Standard Wiring
picofast 4 - Branch Molded Junctions, Standard Wiring Combine 4 Sensors into One Cable Tough Polyurethane Construction For 3-wire DC Sensors or Switches Application Specifications Wiring Diagram Housing
More information