1 RMB-3 Peripheral Unit Installation Guide INSTALLATION GUIDE Westell Technologies Part # Rev. A

2 Copyright 2017 by Westell Technologies. All Rights Reserved. The material discussed in this publication is the proprietary property of Westell Technologies, which retains all rights to reproduction and distribution of this publication. Kentrox is a registered trademark of Westell. All other product names are trademarks or registered trademarks of their respective owners. Information published here is current as of this document s date of publication, but is subject to change without notice. You may verify product information by contacting our headquarters. Westell is an Equal Opportunity/Affirmative Action employer. Westell, Inc. 750 North Commons Drive Aurora, IL USA Toll Free: (800) International: +1 (630) Fax: +1 (630) Technical Support: , option 2 (8 a.m.-6 p.m. Eastern time; follow prompts for after-hours service) Technical support support@westell.com Online Support Portal (Product Documentation Library): (Register for access. Click on Documentation Library. ) Page 1

3 RMB-3 Peripheral Unit Installation Guide This installation guide explains how to install RMB-3 peripheral units. RMB-3 peripheral units are managed by Remote RMX-3200, Remote RMM-1400, Remote RMM-800, or Remote RMC-700 devices. Instructions for configuration of this product are detailed in the following documents: Remote RMX-3200 Command Reference Guide Remote RMX-3200 Configuration Guide Remote RMM-1400 Command Reference Guide Remote RMM-1400 Configuration Guide Remote RMM-800 and Remote RMC-700 Command Reference Guide Remote RMM-800 and Remote RMC-700 Configuration Guide Refer to Product Documentation to access these and other Westell documents. Guide to this document RMB-3 Product Components Cautions and Warnings Customer Assistance Required Items Installation Technical Specifications Page 2

4 RMB-3 Product Components RMB-3 Product Components Front Panel Components, left side Ground bar seat (see inset below) Protection Module Positions Ground bar stud positions (lug attaches here) Chassis Ground (ring terminal attaches here) Dry Contact Inputs Protection Module ground bar Installs onto RMB-3 case Module Mounting Studs 1-4 Surge Protection Modules Install on ground bar face and plug into 4 dry contact inputs 5-Pin Gas Discharge Tube Protectors Up to 4 Plug Into Each Protection Module Front Panel Components, right side Dry Contact Inputs Ethernet ports 4-20 ma Analog Current Input Common 24VDC Power Output 5VDC Power Output Wrist Strap Pierced Lug Terminal Relay Outputs See Pinouts on page 4 Dry Contact Inputs SiteBus Connection 0-10 VDC Analog Voltage Input Common 24VDC Power Output 5VDC Power Output DC Input Power LED DC Power Input Page 3

5 RMB-3 Product Components Pinouts SiteBus Port Ethernet Ports Illuminates when a link is established Blinks when data transfer is active Pin Signal Pin Signal Direction 1 No connection 1 RX+ Input RX- Input 3 No connection 3 TX+ Output 4 data 4 Termination 5 ground 5 Termination 6 No connection 6 TX- Output 7 No connection 7 Termination 8 No connection 8 Termination Dry Contact Inputs RMB-3 provides 24 dry-contact bistate inputs with ground terminals. The inputs numbered 1 through four groups of four -- line the bottom left of the RMB-3 front panel. Each of these 16 inputs can be shielded from inter-building lightning strikes with gas discharge tube protectors plugged into Surge Protection Modules that install over these inputs (see Figure 1). Inputs 17 through 24 are on the RMB-3 front panel left of the two Ethernet ports, and are not surge-protected. A two-position connector is used to connect wires to each dry contact. Surge Protection Modules Surge Protection Modules add inter-building lightning surge protection to up to 16 dry-contact inputs on each RMB-3. One to four optional Surge Protection Modules can be installed to safeguard drycontact inputs The optional Protection Module Ground Bar must be installed first in the case recess above inputs The Surge Protection Modules can be seated in any of four positions above inputs The modules slide over pairs of studs protruding from the ground bar, and are secured with screws in each stud. Male connectors protruding from the lower back of each Protection Module plug into four dry-contact inputs. The Gas Discharge Protectors plug into the upper front of the Protection Module. A two-position cable entry plug goes into dry-contact input openings on the lower front of each module to connect wires. A label supplied with the Protection Modules marks each input number on the lower face of the Protection Module. Page 4

6 RMB-3 Product Components Figure 1 shows an RMB-3 with two Surge Protection Modules and eight Gas Discharge Protectors installed. Note: The Gas Discharge Protectors supplied with the RMB-3 might be black or another color other than red, unlike those shown in the photographs in this guide. Chassis ground connection Protection Module ground bar Gas Discharge Tube Protectors Ground bar studs Torx screws Ground bar studs (lug connection) Two Protection Modules (Cable entry plugs installed on Protection Modules) Two Unused Protection Module seats (Cable entry plugs uninstalled) Ethernet Ports Figure 1 Left side of RMB-3 with two Protection Modules installed The Ethernet ports are labeled 1 and 2. One is used to connect the RMB-3 to its host Remote. The other Ethernet port accommodates daisy-chaining to additional RMB- 3s or other network devices, expanding the I/O capacity. Any ethernet cables leaving the enclosure should be surge-protected. Green LEDs on each Ethernet port show connection status. See Pinouts on page 4. SiteBus Connection The RMB-3 s SiteBus Connection can be used to connect to digital temperature and humidity sensors or other one-wire sensors. Up to 12 one-wire sensors can be connected to the SiteBus interface. Analog Current Input A single 4-20 ma analog current input labeled I is in the left position of the upper four-position cable entry plug (labeled 1) between the SiteBus Connection and the upper Relay Output. The analog current input is to the left of the Common entry (labeled C). See Front Panel Components, right side. Page 5

7 RMB-3 Product Components Analog Voltage Input A single 0-10 VDC analog voltage input labeled V is in the left position of the lower four-position cable entry plug (labeled 2) between the SiteBus Connection and the lower Relay Output. The analog voltage input is to the left of the Common entry (labeled C). See Front Panel Components, right side. 24 VDC Power Outputs Dual 24VDC Power Outputs are in the center right positions of the upper and lower four-position cable inputs between the SiteBus Connection and the Relay Outputs. The upper 24VDC Power Output is labeled, and the lower 24VDC Power Output is labeled 24. In each block, the 24 VDC Power Outputs are between the Common inputs (labeled C) and the 5V Power Outputs. See Front Panel Components, right side. 5VDC Power Outputs Dual 5VDC Power Outputs are in the right positions of the upper and lower fourposition cable inputs between the SiteBus Connection and the Relay Outputs immediately to the right of the 24VDC Power Outputs. The upper 5VDC Power Output is labeled, and the lower 5VDC Power Output is labeled 5. See Front Panel Components, right side. Control Relay Outputs Dual Control Relay Outputs occupy the upper and lower three-position cable inputs immediately to the right of the upper and lower four-position cable inputs described above. Each is labeled NC (normally closed), C (common), and NO (normally open). See Front Panel Components, right side. Wrist Strap Lug Terminal Connection A hex lug connection for a grounding wrist strap is on the right edge of the front of the RMB-3. DC Power Input The DC Power Input is at the lower right corner of the front of the RMB-3. The power wires connect to a two-position cable input secured with screws on each side. See Front Panel Components, right side. The RMB-3 requires a maximum of 8.3W while providing 100 ma at 24VDC and 50 ma at 5VDC. The green LED to the left of the DC power input illuminates when the RMB-3 is powered. Page 6

8 Cautions and Warnings Cautions and Warnings Grounding and Electrical Safety Installation CAUTION: Westell equipment and peripherals contain electrostatic sensitive components. Proper handling, shipping, and storage precautions must be exercised. CAUTION: For Westell equipment to operate safely and correctly, there must be a safety ground strap between the equipment ground bolts and the office ground. CAUTION: The RMB-3 has two ground connections if the Protection Module ground bar is installed (refer to Figure 1). The chassis ground stud protrudes into the recess from the left side of the chassis (outfitted with a vinyl insulated ring terminal secured with a 5/16 OD Keps nut). If the Protection Module ground bar is installed, the two protruding studs on the lower left face of the RMB-3 need to be connected to a ground lug. Both of these grounds can be connected to the same ground bus. Environment CAUTION: In the event that RMB-3 has been subjected to adverse environmental conditions, a service inspection of RMB-3 should be made to ensure safe operation. Restricted Access Locations CAUTION: The RMB-3 is for use in restricted access locations only. FCC The Federal Communications Commission has set limits for emitted radio interference, and RMB-3 is constructed with this electromagnetic interference (EMI) limitation in mind. RMB-3 is classified under FCC regulations as a Class A device, that is, a device for use in commercial environments and not in residential areas. This device has been tested and shown to comply with the following FCC rule: Part 15 Subpart J. Operation of this equipment in a residential area may cause interference to radio and TV Page 7

9 Cautions and Warnings reception, requiring the user to take whatever steps are necessary to correct the interference. Information is available from the FCC describing possible corrective actions. To maintain low EMI levels, we suggest that you use only metal connectors and shielded cable grounded to the frame. Specifications are subject to change without notice. Page 8

10 Customer Assistance Customer Assistance All customers, partners, and resellers who have a valid Westell Support and Services Agreement have complete access to the technical support resources. Pre-sales Support Westell offers pre-sales technical support from 9 a.m. to 5 p.m. Eastern time, Monday - Friday. Representatives are standing by to assist with customer account information and product ordering and answer questions regarding Westell products and solutions. Phone number: , option 1 Before you call or Before you contact Westell for assistance, please have the following information available: The versions of hardware and software you are currently running The error number and exact wording of any messages that appeared on your screen What happened and what you were doing when the problem occurred How you tried to solve the problem Technical Support support is available. You may send at any time during the day; however, responses will be provided only during normal business hours, in accordance with your Service and Support Agreement. To contact Technical Support, send to: support@westell.com Telephone Technical Support Available to qualified Westell customers or partners who have not been able to resolve their technical issue by using our online services. To qualify for support, you must have a valid Support and Services Agreement. Phone number: , option 2 Normal Business Hours: 8 a.m. to 6 p.m. Eastern time After-Hours Support: Available to qualified customers who are experiencing serviceaffecting outages that cannot wait until the next business day. To qualify for after-hours support, you must have a valid 24x7 Support and Services Agreement. Call the number above, option 2, and follow the prompts for after-hours service. Page 9

11 Customer Assistance Product Documentation You can access and view the most current versions of Westell product documentation on our web site at: Select Support Portal from the Services & Support menu. The Documentation Library is part of the Support Portal. Page 10

12 Required Items Required Items Tools Materials #1 Phillips screwdriver #2 Phillips screwdriver 2mm flathead screwdriver (Phoenix 2 mm, recommended) 3mm flathead screwdriver (Phoenix 3 mm, recommended) T10 Torx (aka star ) screwdriver Crimping tool Wire cutter Wire stripper Grounding wrist strap 5/16 nut driver Screws, sized to fit your rack Screws and lock washers to secure mounting brackets to RMB-3 Wire for input power connections (16 AWG solid or stranded insulated) Wire for ground connections (14 AWG, copper conductor) Ground lugs for rack or other earth ground Antioxidant Various required rack cables and cable assemblies Page 11

13 Installation Installation Step 1: Install Host Remote The host Remote RMX-3200, Remote RMM-1400, Remote RMM-800, or Remote RMC- 700 needs to be installed prior to installation of the RMB-3. Follow the installation steps specified in the Installation Guide for the appropriate Remote model and/or the Westell Remote Installation Video series. Refer to Product Documentation to access installation guides and videos. (Optional) Step 2: Install Surge Protection Module Ground Bar Use of surge protection modules on RMB-3 is a recommended option. If surge protection modules are to be used, their underlying ground bar (Westell part # RMB- 3GB) needs to be installed first. This task is easier before the RMB-3 is mounted in a rack, particularly if other equipment is mounted. The ground bar s flat side fits against the rear of the recess on the left side of the RMB-3 cabinet. The protrusion with the ground lug connections seats on the lower left end of the recess. Secure the ground bar to the case with four T10 (star) screws through openings in the long side and one T10 screw between the two ground lug connections. Step 3: Attach Chassis Ground Wire Notes: For ground connections, use 14AWG or larger conductor. Apply an appropriate antioxidant to the bare conductors before crimping the connector to the connector mating surface. Attach the chassis ground wire of appropriate length to the chassis ground stud protruding inward from the left side of the RMB-3 cabinet using the ring terminal and 5/16 Keps nut. Orient the ring terminal pointing out from the cabinet as shown on the left side of Figure 1 and Figure 2. Tip: Tighten the chassis ground connection with a nut driver before installing any Surge Protection Modules. (Optional) Step 4: Install Surge Protection Modules One to four Surge Protection Modules can be installed on the four seats above dry contact connections 1-16 (see Front Panel Components, left side and Figure 1) using these steps: Line up the four male dry contact cable entry plugs on the lower rear of the module with the corresponding female dry contact inputs. At the same time, line up the two openings in the top rear of the module with the pair of studs protruding from the ground bar. Page 12

14 Installation Tip: Place the RMB-3 on its back side, face up, on a firm flat surface so the modules can be installed by pushing them straight down onto the RMB-3. Gently slide the module together with the RMB-3 until it is fully seated against the cabinet and ground bar. The dry contact connectors must be fully engaged and the ground bar studs must slide into the upper openings. Secure the module against the ground bar with two 1/4 #2 Phillips screws in the ground bar studs through the upper openings. Attach two-position cable entry plugs in the dry contact inputs on the front of the module. Stick the appropriate label (Westell part # ) to each module above the cable inputs to identify the dry contacts by the correct numbers. Insert 5-pin Gas Discharge Tube Protectors into position above each dry contact which will be in use. Note: Protection modules add approximately 1.1 inches (2.95 cm) to the depth of the RMB-3. Step 5: Mount RMB-3 The RMB-3 is designed for installation in a 19-inch or 23-inch equipment rack using mounting flanges which attach to each side of the device. For 19-inch racks, orient the flanges with the long side against the RMB-3 as shown in Figure 2. The flanges can be shifted forward or backward and/or flipped to mount the RMB-3 flush with the rack front, forward, or recessed. Attach each flange securely with three screws and lock washers. For 23-inch racks, orient the flanges with the short side against the RMB-3. Follow the same steps as above. Mount the RMB-3 in the desired rack location with four screws. Figure 2 RMB-3 with mounting flanges oriented for flush mount in 19-inch rack Step 6: Connect Grounds Notes: For ground connections, use 14AWG or larger conductor. Apply an appropriate antioxidant to the bare conductors before crimping the connector to the connector mating surface. Page 13

15 Installation Connect the Chassis Ground using the ring terminal provided (see Front Panel Components, left side, and/or Figure 1). Connect the Ground Bar ground using the two-hole copper compression lug provided. Make both connections to a suitable ground such as the frame ground of a rack system or a reliable earth ground. CAUTION: The chassis ground must be connected to the same earthing electrode conductor as the DC supply system or to a bonding jumper (from an earthing terminal or bus) connected to the earthing electrode of the DC supply system. The chassis must be located in the same immediate area (such as adjacent cabinets) as other equipment connected to the same DC power system and earthing electrode conductor. The DC system cannot be earthed elsewhere. The DC power source must be located in the same premises as the chassis. No switching or disconnecting devices can occur between the earthed conductor of the DC source and the earthing electrode conductor. Step 7: Connect Remote to RMB-3 Use a standard CAT5 Ethernet cable (such as Westell part number CAB182-10) to connect a Westell Remote Ethernet port to the Ethernet port on RMB-3. Green LEDs on each Ethernet port show connection status. See Pinouts on page 4. Once the RMB-3 connection to the Remote is successful, the RMB-3 can be put into service as described in chapter Configuring the Peripheral Management Subsystem in your Remote model Configuration Guide. Step 8: Connect other RMB-3 Inputs and Outputs RMB-3 dry-contact connections, analog current and analog voltage connections, and relay connections all use cable entry terminals that plug into the front of the RMB-3 or its seated Protection Modules. All removable connectors support 16 to 20 gauge wire, stranded or solid. Westell recommends stranded conductor wiring for all inputs and outputs for reliability of connections which may be removed on occasion. Wires are inserted in the appropriate input and secured by tightening the corresponding screw on top of the plug. It may be easiest to unplug the terminal to insert and secure the wires. The installer can, as needed, gently pry a terminal out of its input using a small flathead screwdriver. Once the wires are secured, plug the terminal back into the correct input, and test the connection by gently tugging on each wire. Page 14

16 Installation CAUTION: Please contact Westell (Telephone Technical Support or Technical Support) prior to connecting any external wetting voltage source to the RMB-3. Make sure a functional 5-Pin Gas Discharge Tube Protector is installed above each drycontact input in use in Protection Modules. Refer to Surge Protection Modules. Connections to the Ethernet and SiteBus ports are made using a standard CAT5 Ethernet cables. The RMB-3 is designed so that one Ethernet port connects to the host Remote, and the other connects to another RMB-3 or other network device. RMB-3s can be daisy-chained together in this manner to expand I/O capacity as needed. The SiteBus port accommodates one-wire digital temperature and humidity sensors. Step 9: Connect DC Power Input WARNING: Turn off the power feed before connecting wires. CAUTION: A readily accessible disconnect device (suitably approved and rated) must be incorporated in the field wiring. Connect the input power feed to the two-position DC power input connector in the lower right corner of the RMB-3 (see Front Panel Components, right side) using the steps listed below. Be careful to observe polarity. Notes: Connect power connector to a reliably grounded +/-20 to 60 VDC safety extra-low voltage (SELV) source. Use 16 AWG copper conductors. Typical circuit fuse: 3 A To connect wires: 1. Turn off power feed. 2. Strip ends of wire 5/16 in. (7 mm). 3. (optional) Using a small flathead screwdriver, loosen screws on sides of power connector on the bottom right front of RMB-3. Remove the power connector as necessary. 4. Apply an appropriate antioxidant to the conductor surfaces. Then insert wires into the correct connector inputs and tighten the screws on top of the connector. 5. Replace and tighten the connector in the DC power input as necessary. Page 15

17 Installation When the above steps are complete, turn on the power supply. The green LED left of the DC power input illuminates when the RMB-3 is powered. Page 16

18 Technical Specifications Technical Specifications Specification Weight Size Mounting Operating Environment (Ambient) Power Input/Output Ports SiteBus Temperature Sensor Description Approx. 2.3 lb (1.035 kg) With ground bar and 4 Protection Modules: Approx. 3.3 lbs. (1.5 kg) Height: 1.67 in. (4.175 cm) Width: in. (42.38 cm) Depth: 3.9 in. (9.75 cm) Depth with Protection Modules: 5 in. (12.7 cm) Mounts in a standard 19-in. or 23-in. rack Temperature: -30 to 60 C (-22 to 140 F) Relative humidity: 0% to 95% (non-condensing) 8.3W max while providing VDC and 50 5VDC 24 dry-contact digital inputs. 16 dry-contact digital inputs with optional inter-building lightning surge protection provided by plug-in modules 1 analog voltage input: Range: 0 to 10 VDC (positive voltage only) Input impedance: greater than or equal to 1 mega Ohm Accuracy: +/-2% of full-scale 1 analog current input: Range: 4 to 20 ma DC Input impedance: 100 Ohm Accuracy: +/-2% of full-scale 2 control relay outputs: Contact rating: 30 VDC at 2 A resistive Contact type: Form C 1 SiteBus One Wire Interface: Up to 12 One Wire sensors 2 24VDC Power Outputs: 8.3W maximum while providing 100ma 2 5VDC Power Outputs: 8.3W maximum while providing 50ma Range: -55 to 125 C (-67 to 257 F) Accuracy: +/- 0.5 C from -10 to 85 C Page 17

RMB Peripheral Units Installation Guide

RMB Peripheral Units Installation Guide RMB Peripheral Units Installation Guide Part Number 65-000101 2011 by Kentrox, Inc. All rights reserved. Copyright 2011 by Kentrox, Inc. All Rights Reserved. The material discussed in this publication

More information

Remote RMM-1400 Intelligent Remote Site Management Device. Installation Guide

Remote RMM-1400 Intelligent Remote Site Management Device. Installation Guide Remote RMM-1400 Intelligent Remote Site Management Device Guide INSTALLATION GUIDE Westell Technologies Part # 030-300645 Rev. A Copyright 2015 by Westell Technologies. All Rights Reserved. Westell, Kentrox

More information

INSTALLATION GUIDE. Remote RMM-700 Intelligent Site Management Device. Installation Guide WESTELL.COM

INSTALLATION GUIDE. Remote RMM-700 Intelligent Site Management Device. Installation Guide WESTELL.COM Remote RMM-700 Intelligent Site Management Device Guide INSTALLATION GUIDE Westell Technologies April 2015 Part # 030-300653 Rev. A Copyright 2015 by Westell, Inc. All Rights Reserved. Westell, Kentrox,

More information

INSTALLATION GUIDE. Remote RMM-800 Intelligent Site Management Device. Installation Guide WESTELL.COM

INSTALLATION GUIDE. Remote RMM-800 Intelligent Site Management Device. Installation Guide WESTELL.COM Remote RMM-800 Intelligent Site Management Device Guide INSTALLATION GUIDE Westell Technologies July 2016 Part # 030-300731 Rev. C Copyright 2016 by Westell, Inc. All Rights Reserved. Westell, Kentrox,

More information

AI130 AIswitch Series 130 Chassis Installation Guide

AI130 AIswitch Series 130 Chassis Installation Guide AI130 AIswitch Series 130 Chassis Installation Guide Part Number QR-130 Rev 3 2007 by Kentrox, Inc. All rights reserved. Copyright 2007 by Kentrox, Inc. All Rights Reserved. The material discussed in this

More information

AI port High Speed Asynchronous Line Card Installation Guide

AI port High Speed Asynchronous Line Card Installation Guide AI232 32-port High Speed Asynchronous Line Card Installation Guide Part Number QR-232 Rev 3 2008 by Kentrox, Inc. All rights reserved. Copyright 2008 by Kentrox, Inc. All Rights Reserved. The material

More information

AI180I AIswitch Series 180 Integrated Chassis Installation Guide

AI180I AIswitch Series 180 Integrated Chassis Installation Guide AI180I AIswitch Series 180 Integrated Chassis Installation Guide Part Number QR-180I Rev 5 2008 by Kentrox, Inc. All rights reserved. Copyright 2008 by Kentrox, Inc. All Rights Reserved. The material discussed

More information

TRC-190 User s Manual

TRC-190 User s Manual User s Manual Edition 3.2, May 2017 www.moxa.com/product 2017 Moxa Inc. All rights reserved. User s Manual The software described in this manual is furnished under a license agreement and may be used only

More information

Remote RMX-3200 Intelligent Site Management Device. Installation Guide

Remote RMX-3200 Intelligent Site Management Device. Installation Guide Remote RMX-3200 Intelligent Site Management Device Installation Guide INSTALLATION GUIDE Westell Technologies Part # 030-300637 Rev. A Copyright 2015 by Westell Technologies. All Rights Reserved. Westell,

More information

Junos WebApp Secure 5.0 Hardware Guide

Junos WebApp Secure 5.0 Hardware Guide Junos WebApp Secure 5.0 Hardware Guide Junos WebApp Secure 5.0 Hardware Guide This document contains a specification for the MWS1000 hardware appliance, as well as instructions for installation into a

More information

Replacing the Power Supply

Replacing the Power Supply APPENDIX B This appendix includes information on how to replace the power supply for the Cisco AS550XM universal gateway and contains the following sections: Safety Recommendations, page B-1 Required Tools

More information

TRC-190 User s Manual

TRC-190 User s Manual First Edition, November 2008 www.moxa.com/product 2008 Moxa Inc. All rights reserved. Reproduction without permission is prohibited. The software described in this manual is furnished under a license agreement

More information

Installation of the POTS splitter card requires the following steps: Determining the cables you need. Installing the POTS splitter chassis

Installation of the POTS splitter card requires the following steps: Determining the cables you need. Installing the POTS splitter chassis 5910 High Density Lifeline POTS Splitter Installation Instructions Document Number 5910-A2-GZ40-00 May 2005 About the 5910 POTS Splitter The 5910 is a double-density POTS splitter that separates the (Digital

More information

Site Preparation CHAPTER

Site Preparation CHAPTER CHAPTER 3 Site Preparation This chapter describes the steps to take and the considerations you should keep in mind prior to installing the modules in an open rack. It also contains information that applies

More information

Installation Note for the Cisco ME 3800X and ME 3600X Switch Power Supply and Fan Modules

Installation Note for the Cisco ME 3800X and ME 3600X Switch Power Supply and Fan Modules Installation Note for the Cisco ME 3800X and ME 3600X Switch Power Supply and Fan Modules This document provides the installation and removal instructions for the AC and DC input power supply and fan modules

More information

Power Supply Installation

Power Supply Installation Power Supply Module Overview, on page Installation Guidelines, on page 4 Installing or Replacing an AC Power Supply, on page 6 Installing a DC Power Supply, on page 7 Finding the Power Supply Module Serial

More information

Power Supply and Fan Module Installation

Power Supply and Fan Module Installation 3 CHAPTER This chapter describes how to remove and install a new or replacement power supply or fan module in a Catalyst 3750-E or Catalyst 3560-E switch. See these sections: Installation Overview, page

More information

Perle MCR200 Installation Guide

Perle MCR200 Installation Guide Perle MCR200 Installation Guide P/N 5500322-10 Introduction The Perle MCR200 Chassis is a 2 slot chassis able to accommodate up to 2 Perle Media Converter modules or 1 Media Converter Module and an MCR-MGT

More information

Dual-Feed 80A Auto Low Voltage Disconnect Panel - 80LVD02

Dual-Feed 80A Auto Low Voltage Disconnect Panel - 80LVD02 Dual-Feed 80A Auto Low Voltage Disconnect Panel - 80LVD02 User Manual 1.1 Overview Telect s 80A, -48 Vdc Low-Voltage Disconnect (LVD) panel is a rack-mounted component with coil-operated contactors. These

More information

User s Guide CPSMC0200-2x0 Dual-Slot PointSystem Chassis

User s Guide CPSMC0200-2x0 Dual-Slot PointSystem Chassis User s Guide CPSMC0200-2x0 Dual-Slot PointSystem Chassis The Transition Networks CPSMC0200-2x0 series dual-slot PointSystem chassis is designed for installation of one or two selectable Transition Networks

More information

Quick Start. This document describes how to install the Juniper Networks PTX5000 Packet Transport

Quick Start. This document describes how to install the Juniper Networks PTX5000 Packet Transport PTX5000 Packet Transport Router Quick Start September 2017 Part Number: 530-066788 Revision 01 This document describes how to install the Juniper Networks PTX5000 Packet Transport Router. Contents Quick

More information

M5 and M10 Routers Power Supply and Power Cord Component Replacement Instructions

M5 and M10 Routers Power Supply and Power Cord Component Replacement Instructions M5 and M10 Routers Power Supply and Power Cord Component Replacement Instructions Part No. 530-003244-01 Revision 1 27 July 2000 This document describes how to remove and replace the AC and DC power supplies,

More information

FLEX Ex Spring Clamp Terminal Base

FLEX Ex Spring Clamp Terminal Base Installation Instructions FLEX Ex Spring Clamp Terminal Base (Cat. No. 1797-TB3S) 1 10 11 4 Only remove this cover plug if connecting another terminal base unit. 3 5 6 12 2 7 8 9 41253 Component Identification

More information

Installation Job Aid for Ethernet Routing Switch 3600 Series

Installation Job Aid for Ethernet Routing Switch 3600 Series Installation Job Aid for Ethernet Routing Switch 3600 Series Notices NN47213-303 Issue 03.01 November 2017 Notice paragraphs alert you about issues that require your attention. Following are descriptions

More information

OPTICAL HEADEND PLATFORM OTOHP-CH 3RU CHASSIS OTOHP-PS POWER SUPPLY MODULE OTOHP-BP BLANK PANEL INSTRUCTION MANUAL

OPTICAL HEADEND PLATFORM OTOHP-CH 3RU CHASSIS OTOHP-PS POWER SUPPLY MODULE OTOHP-BP BLANK PANEL INSTRUCTION MANUAL OPTICAL HEADEND PLATFORM OTOHP-CH 3RU CHASSIS OTOHP-PS POWER SUPPLY MODULE OTOHP-BP BLANK PANEL INSTRUCTION MANUAL Phone: (209) 586-1022 (800) 545-1022 Fax: (209) 586-1026 OTOHP-CH Rev. X1 E-Mail: salessupport@olsontech.com

More information

WIRESPEED ADSL MODEM (MODEL 2000) User Guide

WIRESPEED ADSL MODEM (MODEL 2000) User Guide WIRESPEED ADSL MODEM (MODEL 2000) User Guide Copyright 2001 Westell, Inc. All rights reserved. 030-300187 Rev. A Printed in the United States of America December 2001 CONTENTS 1. PRODUCT DESCRIPTION...

More information

TCNM-ACBB1 Installation Manual

TCNM-ACBB1 Installation Manual The TCNM-ACBB1 is a connection box that can be used as an accessory to facilitate system connections for installation and device replacement of several Banner family reading devices. System cabling is

More information

Connecting Power and Ground

Connecting Power and Ground This chapter explains how to connect the power and ground for NCS 2006 shelf. The sections are: Power and Ground Description, page 1 NTP-L12 Installing Power and Ground to the NCS 2006 Shelf, page 2 Power

More information

Release Notes. Electrostatic Discharge and Grounding Guide for Cisco NCS 2000 Series. Prerequisites. Preparing Your Location

Release Notes. Electrostatic Discharge and Grounding Guide for Cisco NCS 2000 Series. Prerequisites. Preparing Your Location First Published: 2017-01-31 Text Part Number: Electrostatic Discharge and Grounding Guide for Cisco NCS 2000 Series Prerequisites This document uses illustrations to explain the workflow that we recommend

More information

Installing the Cisco AS5400XM Universal Gateway

Installing the Cisco AS5400XM Universal Gateway CHAPTER 3 Installing the Cisco AS5400XM Universal Gateway This chapter guides you through the installation of the Cisco AS5400XM universal gateway and includes the following sections: Setting Up the Chassis,

More information

Installing the Cisco 2524 and Cisco 2525 Routers

Installing the Cisco 2524 and Cisco 2525 Routers CHAPTER 3 Installing the Cisco 2524 and Cisco 2525 Routers This chapter guides you through the installation of the Cisco 2524 and Cisco 2525 routers and includes the following sections: Required Tools

More information

1. Carefully unpack the um260 s shipping carton and check the contents for damage.

1. Carefully unpack the um260 s shipping carton and check the contents for damage. um260 Installation Manual um260 Installation Chapter 4 um260 MICRO MONITOR INSTALLATION This section of the um260 Micro Monitor Installation Manual describes the requirements and procedures for installing

More information

Enclosure TS-530 User Manual

Enclosure TS-530 User Manual Enclosure TS-530 User Manual 16525 East Laser Drive Fountain Hills, AZ 85268 TEL 480.837.5200 FAX 480.837.5300 info@embeddedx86.com http://www.embeddedx86.com/ Technologic Systems, Inc. COPYRIGHT 1998-200

More information

MC 11 EB-2 Power supply cabinet with external bus, AC version

MC 11 EB-2 Power supply cabinet with external bus, AC version MC 11 EB-2 Power supply cabinet with external bus, AC version USER/MAINTENANCE MANUAL 1 SLOT 0 SLOT 1 SLOT 2 SLOT 3 SLOT 4 SLOT 5 SLOT 6 SLOT 7 SLOT 8 SLOT 9 SLOT 10 SLOT 11 EB-2 (a) MC11 (b) (c) Figures

More information

Installing And Programming The Analog Terminal Interface On The DXP, DXP Plus, and FX Series Digital Communications Systems

Installing And Programming The Analog Terminal Interface On The DXP, DXP Plus, and FX Series Digital Communications Systems R Installing And Programming The Analog Terminal Interface On The DXP, DXP Plus, and FX Series Digital Communications Systems The Analog Terminal Interface The ATI-D-1PT is a multipurpose, on-premise accessory

More information

Cisco CRS 3-Phase AC Power Distribution Unit Installation Guide 2. Cisco CRS 3-Phase AC Power Distribution Unit 2

Cisco CRS 3-Phase AC Power Distribution Unit Installation Guide 2. Cisco CRS 3-Phase AC Power Distribution Unit 2 Cisco CRS 3-Phase AC Power Distribution Unit Installation Guide Cisco CRS 3-Phase AC Power Distribution Unit Installation Guide 2 Cisco CRS 3-Phase AC Power Distribution Unit 2 Revised: November 18, 2016,

More information

Follow the procedure below for unpacking the carton in which the device is shipped. DW-GTW-AC-E1060 Four anti-slide bumpers for desktop installation

Follow the procedure below for unpacking the carton in which the device is shipped. DW-GTW-AC-E1060 Four anti-slide bumpers for desktop installation 1 Introduction This document provides a hardware description of the DW-GTW-AC-E1060 (hereafter referred to as device) and step-by-step procedures for mounting and cabling the device. The device supports

More information

Installation Notes for the Catalyst 3750-X and 3560-X Switch Power Supply Modules

Installation Notes for the Catalyst 3750-X and 3560-X Switch Power Supply Modules Installation Notes for the Catalyst 3750-X and 3560-X Switch Power Supply Modules Published: April, 2010 Revised: April, 2013 For information about using the power supply modules with a switch, see the

More information

Installation Notes TII Model 341 Protector

Installation Notes TII Model 341 Protector Installation Notes TII Model 341 Protector (ATT-IS PEC 32918) for MERLIN Communications System In Range Out of Building (IROB) Station Installation By Trained Technician Only WARNING: Failure to follow

More information

This simple chassis houses one media-converter module and features an external AC power supply and also a terminal block for DC power input.

This simple chassis houses one media-converter module and features an external AC power supply and also a terminal block for DC power input. LMC5103A-R2 1-slot Multipower Desktop Chassis (Module Not Included) This simple chassis houses one media-converter module and features an external AC power supply and also a terminal block for DC power

More information

Mercury Helios ASSEMBLY MANUAL & USER GUIDE

Mercury Helios ASSEMBLY MANUAL & USER GUIDE Mercury Helios ASSEMBLY MANUAL & USER GUIDE TABLE OF CONTENTS INTRODUCTION...1 1.1 MINIMUM SYSTEM REQUIREMENTS 1.1.1 Apple Mac Requirements 1.1.2 PC Requirements 1.1.3 Supported PCIe Cards NOTE: Boot Camp

More information

Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual

Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual Omnitron Systems Technology, Inc. 1 iconverter 19-Module Managed Power Chassis User s Manual 27 Mauchly, #201, Irvine, CA 92618 Phone: (949) 250-6510; Fax: (949) 250-6514 2 Omnitron Systems Technology,

More information

Bluetooth Shielding Instructions

Bluetooth Shielding Instructions Mac mini 2012 Bluetooth Shielding Instructions 1 INTRODUCTION 1.1 STATIC PRECAUTIONS 1.2 TOOLS REQUIRED 2 DISASSEMBLY 3 SHIELDING 4 FAQ 4.1 FAQ 5 CUSTOMER SERVICE 5.1 Before Contacting Customer Service

More information

HX WCS Indoor DAS Remote Unit Quick Installation Sheet

HX WCS Indoor DAS Remote Unit Quick Installation Sheet HX WCS Indoor DAS Remote Unit Quick Installation Sheet CMA-447-AEN GENERAL INFORMATION 1. The HX WCS remote is an upgrade unit and is installed in conjunction with an existing HX and/or MA1000/ MA2000

More information

Installation Job Aid for Ethernet Routing Switch 5900 Series

Installation Job Aid for Ethernet Routing Switch 5900 Series Installation Job Aid for Ethernet Routing Switch 5900 Series Notices NN47211-301 Issue 05.01 November 2017 Notice paragraphs alert you about issues that require your attention. The following paragraphs

More information

OWC Mercury Helios 2 ASSEMBLY MANUAL & USER GUIDE

OWC Mercury Helios 2 ASSEMBLY MANUAL & USER GUIDE OWC Mercury Helios 2 ASSEMBLY MANUAL & USER GUIDE TABLE OF CONTENTS 1. INTRODUCTION...1 1.1 MINIMUM SYSTEM REQUIREMENTS 1.1.1 Apple Mac Requirements 1.1.2 PC Requirements 1.1.3 Supported PCIe Cards 1.2

More information

CPCI-PS24 24V-Power Supply

CPCI-PS24 24V-Power Supply 24V-Power Supply Hardware Manual to Product I.2301.21 esd electronic system design gmbh Vahrenwalder Str. 207 30165 Hannover Germany http://www.esd.eu Phone: +49 (0) 511 3 72 98-0 Fax: +49 (0) 511 3 72

More information

User Guide CPSMP VAC Power Supply Module: PointSystem CPSMC Accessory CPSMC Accessory. Contents.

User Guide CPSMP VAC Power Supply Module: PointSystem CPSMC Accessory CPSMC Accessory. Contents. User Guide CPSMP-205 110 240 VAC Power Supply Module: PointSystem CPSMC1800-200 Accessory CPSMC1900-100 Accessory Contents Contents...1 Description...1 Cautions and Warnings...2 Definitions...2 Power supply

More information

InnoMedia Business VoIP ATA Models

InnoMedia Business VoIP ATA Models InnoMedia Business VoIP ATA Models MTA8328-4, MTA8328-8, MTA8328-24 Quick Installation Guide Important Safety Instructions Protective Earthing Protective earthing is used as a safeguard. This equipment

More information

LOOP-IP 6100 Series High Speed Ethernet Interface Unit Users Manual for: Loop-IP 6100-DS3 Loop-IP 6100-DS3R Loop-IP 6100-E3 Loop-IP 6100-E3R

LOOP-IP 6100 Series High Speed Ethernet Interface Unit Users Manual for: Loop-IP 6100-DS3 Loop-IP 6100-DS3R Loop-IP 6100-E3 Loop-IP 6100-E3R LOOP-IP 6100 Series High Speed Ethernet Interface Unit Users Manual for: Loop-IP 6100-DS3 Loop-IP 6100-DS3R Loop-IP 6100-E3 Loop-IP 6100-E3R LOOP TELECOMMUNICATION INTERNATIONAL, INC. 8F, NO. 8, HSIN ANN

More information

PACSystems RX7i IC698CHS009/119

PACSystems RX7i IC698CHS009/119 January 2010 The RX7i rack can be used for all RX7i CPU and I/O configurations, Series 90-70 I/O, and VME modules. Backplane connectors are spaced on 0.8" (20.3mm) centers to accommodate single-width RX7i

More information

SySTIUM TECHNOLOGIES. Assembly Guide. Model 133i

SySTIUM TECHNOLOGIES. Assembly Guide. Model 133i Assembly Guide Model 133i Radio Frequency Interference Notice (USA) This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules,

More information

Obtaining Documentation and Submitting a Service Request, page xvii Safety Warnings, page xvii Safety Guidelines, page xx

Obtaining Documentation and Submitting a Service Request, page xvii Safety Warnings, page xvii Safety Guidelines, page xx Preface Obtaining Documentation and Submitting a Service Request, page xvii Safety s, page xvii Safety Guidelines, page xx Obtaining Documentation and Submitting a Service Request For information on obtaining

More information

Installation and Maintenance

Installation and Maintenance CHAPTER 4 Installation and Maintenance Revised: April 19, 2010, Introduction This chapter explains how to install a SCE 1000 platform in a rack or in a general tabletop or workbench installation. Additionally,

More information

This Datasheet for the IC670GBI002 24VDC BUS INTERFACE UNIT.

This Datasheet for the IC670GBI002 24VDC BUS INTERFACE UNIT. This Datasheet for the IC670GBI002 24VDC BUS INTERFACE UNIT http://www.qualitrol.com/shop/p-14508-ic670gbi002.aspx Provides the wiring diagrams and installation guidelines for this GE Field Control module.

More information

The Programmable 4-Way Relay Card is an optional peripheral unit that provides four individually programmable relay output circuits.

The Programmable 4-Way Relay Card is an optional peripheral unit that provides four individually programmable relay output circuits. Peripheral Relay The Programmable 4-Way Relay Card is an optional peripheral unit that provides four individually programmable relay output circuits. Up to 16 Cards can be connected to a multi-loop panel

More information

EXN4000 Storage Expansion Unit Installation and Setup Instructions

EXN4000 Storage Expansion Unit Installation and Setup Instructions IBM System Storage EXN4000 Storage Expansion Unit Installation and Setup Instructions GC27-2079-02 IBM System Storage EXN4000 Storage Expansion Unit Installation and Setup Instructions GC27-2079-02 Notices

More information

Analog Monitor Installation Manual

Analog Monitor Installation Manual Analog Monitor Installation Manual Part Number: 144-23919 Copyright 2011 Magnetek 1. Preface and Safety Magnetek manufactures products used as components in a wide variety of industrial systems and equipment.

More information

TN-5308 Quick Installation Guide

TN-5308 Quick Installation Guide TN-5308 Quick Installation Guide Moxa ToughNet Switch Edition 6.0, February 2017 Technical Support Contact Information www.moxa.com/support Moxa Americas: Toll-free: 1-888-669-2872 Tel: 1-714-528-6777

More information

S4112-ON Series. Setup Guide

S4112-ON Series. Setup Guide S4112-ON Series Setup Guide Notes, cautions, and warnings NOTE: A NOTE indicates important information that helps you make better use of your product. CAUTION: A CAUTION indicates either potential damage

More information

Installation Guide V290 (Color) This guide provides basic information for Unitronics LCD color touchscreen models V C30B and V T40B.

Installation Guide V290 (Color) This guide provides basic information for Unitronics LCD color touchscreen models V C30B and V T40B. Vision OPLC Installation Guide V290 (Color) This guide provides basic information for Unitronics LCD color touchscreen models V290-19-C30B and V290-19-T40B. General Description Vision OPLCs are programmable

More information

E2460GS Oscilloscope Upgrade Kit

E2460GS Oscilloscope Upgrade Kit Installation Instructions for E2460GS Oscilloscope Upgrade Kit Agilent 1670G-Series Logic Analyzers This kit upgrades either the Agilent Technologies 1670G, Agilent 1671G, Agilent 1672G, or the Agilent

More information

16-Port Chassis Media Converter System Manual

16-Port Chassis Media Converter System Manual 16-Port Chassis Media Converter System Manual 17732-B 16-Port Media Converter (ST Connectors, Shown) INTRODUCTION This system manual describes the ADC 16-Port Media Converter with SC and ST connectors,

More information

ISOLATION RELAY RACK ISOLATION KIT 19 RACK MOUNT RELAY RACK ISOLATION KIT, SLOTTED UNEQUAL FLANGE RACK ISOLATION KIT 23 RACK MOUNT

ISOLATION RELAY RACK ISOLATION KIT 19 RACK MOUNT RELAY RACK ISOLATION KIT, SLOTTED UNEQUAL FLANGE RACK ISOLATION KIT 23 RACK MOUNT ISOLATION Info: 9070 = Isolation RELAY RACK ISOLATION KIT 19 RACK MOUNT 9070-1019 19" Rack Mount 23 RACK MOUNT 9070-1023 23" Rack Mount RELAY RACK ISOLATION (KIT) RELAY RACK ISOLATION KIT, SLOTTED 19 RACK

More information

Analog Input Installation Manual

Analog Input Installation Manual Analog Input Installation Manual August 2011 Part Number: 144-23917 Copyright 2011 Magnetek 1. Preface and Safety Magnetek manufactures products used as components in a wide variety of industrial systems

More information

USER MANUAL MODEL 2017P MODEL 2017P60. RS-232 to 20mA and. RS-232 to 60mA Current Loop Converters

USER MANUAL MODEL 2017P MODEL 2017P60. RS-232 to 20mA and. RS-232 to 60mA Current Loop Converters USER MANUAL MODEL 2017P RS-232 to 20mA and MODEL 2017P60 RS-232 to 60mA Current Loop Converters 07M2017P-E Doc# 073051UE Revised 5/7/96 SALES OFFICE (301) 975-1000 TECHNICAL SUPPORT (301) 975-1007 1.0

More information

Installing a Power over Ethernet injector

Installing a Power over Ethernet injector Installing a Power over Ethernet injector AlphaEclipse StreetSmart and RoadStar signs The instructions in this document explain how to install/replace a Power over Ethernet (PoE) injector in a StreetSmart

More information

60W Power over Ethernet Waterproof Adapter PoE IEEE BT Single Port Injector for Outdoor Application

60W Power over Ethernet Waterproof Adapter PoE IEEE BT Single Port Injector for Outdoor Application WWW.PHIHONG.COM 60W Power over Ethernet Waterproof Adapter PoE IEEE BT Single Port Injector for Outdoor Application Features Compliant with the IEEE802.3bt Standard Non-Vented Case with Mounting Bracket

More information

Installation Instructions

Installation Instructions Installation Instructions (Cat. No. 1794-TBN) 6 1 5 9 4 2 3 10 6 7 8 Component Identification 1 Female flexbus connector 2 Terminal base unit (1794-TBN) 3 Male flexbus connector 4 Keyswitch Set to the

More information

(Cat. No A1B, -A2B, -A3B, -A3B1, -A4B Series B) Installation Data. Make sure you have these items:

(Cat. No A1B, -A2B, -A3B, -A3B1, -A4B Series B) Installation Data. Make sure you have these items: (Cat. No. 1771-A1B, -A2B, -A3B, -A3B1, -A4B Series B) Installation Data Make sure you have these items: Important: Make sure you meet these minimum spacing requirements. 2 3 4 Each enclosure must contain

More information

Altivar 61/71 Adjustable Speed Drives Heatsink Fan Kits VZ3V1212 and VZ3V1216

Altivar 61/71 Adjustable Speed Drives Heatsink Fan Kits VZ3V1212 and VZ3V1216 Altivar 61/71 Adjustable Speed Drives Heatsink Fan Kits VZ3V1212 and VZ3V1216 Instruction Bulletin 30072-452-48 Retain for future use. 30072-452-48 Altivar 61/71 Heatsink Fan Kits VZ3V1212 and VZ3V1216

More information

Installing the Cisco VG224 Voice Gateway

Installing the Cisco VG224 Voice Gateway CHAPTER 3 This chapter contains the procedures for installing your Cisco VG224 voice gateway and consists of the following sections: Safety Recommendations, page 3-2 Site Log, page 3-3 Keeping Track Checklist,

More information

Install the Cisco ONS CL

Install the Cisco ONS CL 1 CHAPTER This chapter provides procedures for installing the Cisco ONS 15310-CL shelf, cards, and fiber-optic cable. To view a summary of the tools and equipment required for installation, see the Required

More information

Preparing to Install the VG248

Preparing to Install the VG248 CHAPTER 2 To ensure normal system operation, plan your site configuration and prepare your site before installation. Before installing the VG248, review these sections: Preparing the Installation Site,

More information

3M Wrist Strap and Ground Monitor 773. User s Guide

3M Wrist Strap and Ground Monitor 773. User s Guide 3M Wrist Strap and Ground Monitor 773 User s Guide Table of Contents Section Page Safety Information... 2 1 Description... 4 Overview... 4 Performance... 4 2 Installation... 5 Supplied Parts... 5 Wire

More information

User s Guide. Mobile Rack Device Mounting Kit for Echo Express III-R and xmac Pro Server. Quick Start Guide Video Available Online!

User s Guide. Mobile Rack Device Mounting Kit for Echo Express III-R and xmac Pro Server. Quick Start Guide Video Available Online! User s Guide Mobile Rack Device Mounting Kit for Echo Express III-R and xmac Pro Server Quick Start Guide Video Available Online! Visit http://www.sonnettech.com/product/ mobilerackkit.html Click the Video

More information

C5C Cross-Connect System

C5C Cross-Connect System C5C Cross-Connect System I N S T A L L A T I O N I N S T R U C T I O N High-Density Connection Blocks 1.0 General Product Information The C5C cross-connect system is comprised of a high-density connection

More information

28-Position 23 Rack Mounting Model RM23-20X

28-Position 23 Rack Mounting Model RM23-20X 001-0048 Rev.00 28-Position 23 Rack Mounting Model RM23-20X SECTION PAGE # 1. GENERAL... 1 2. APPLICATIONS... 1 3. INSTALLATION... 1 4. TESTING... 3 5. CUSTOMER SERVICES... 3 6. WARRANTY AND REPAIRS...

More information

UNT1100 Series. Binary Output Jumpers AO2 AO1 AO3 AO4 AOCM AOCM AOCM AOCM AO1. AI Switches Job Information N2 Address. Ref N2+ N2- ADDR 0 = ALL OPEN

UNT1100 Series. Binary Output Jumpers AO2 AO1 AO3 AO4 AOCM AOCM AOCM AOCM AO1. AI Switches Job Information N2 Address. Ref N2+ N2- ADDR 0 = ALL OPEN 1 2 8 4 AI6 R R Installation Bulletin UNT1100 Issue Date 0309 UNT1100 Series Introduction The Unitary (UNT) controller (UNT1100 Series) is a digital controller with applications for air handling units,

More information

LVN5200A-R2, rev. 1, Hardware Installation Guide

LVN5200A-R2, rev. 1, Hardware Installation Guide LVN5200A-R2 LVN5250A-R2 LVN5200A-R2, rev. 1, Hardware Installation Guide Customer Support Information Order toll-free in the U.S.: Call 877-877-BBOX (outside U.S. call 724-746-5500) FREE technical support

More information

TABLE OF CONTENTS INTRODUCTION...1 DEVICE SETUP...4 SUPPORT RESOURCES...9

TABLE OF CONTENTS INTRODUCTION...1 DEVICE SETUP...4 SUPPORT RESOURCES...9 TABLE OF CONTENTS INTRODUCTION...1 1.1 Minimum System Requirements 1.2 Package Contents 1.3 About This Manual 1.4 Rear View 1.4.1 Rear Features 1.5 Usage Notes DEVICE SETUP...4 2.1 Quick Start 2.2 Assembly

More information

Basketball Shot Clock Set LX2180 Manual

Basketball Shot Clock Set LX2180 Manual Basketball Shot Clock Set LX2180 Manual 72 Industrial Boulevard Wrightsville, GA 31096 Phone: (800) 445-7843 Fax: (800) 864-0212 www.electro-mech.com LX2180 Revision 5 February 8, 2013 Table of Contents

More information

Navigator II INstallatIoN MaNUal For static and PaN/tIlt configurations

Navigator II INstallatIoN MaNUal For static and PaN/tIlt configurations Navigator II Installation MANUAL For Static and Pan/Tilt Configurations Document Number: 432-0001-00-12, rev 100 FLIR Systems, Inc., 2008. All rights reserved worldwide. No parts of this manual, in whole

More information

Installation Guide V290 (Color) This guide provides basic information for Unitronics LCD color touchscreen models V C30B and V T40B.

Installation Guide V290 (Color) This guide provides basic information for Unitronics LCD color touchscreen models V C30B and V T40B. Vision OPLC Installation Guide V290 (Color) This guide provides basic information for Unitronics LCD color touchscreen models V290-19-C30B and V290-19-T40B. General Description Vision OPLCs are programmable

More information

This installation guide describes how to install and connect signals to the NI TBX-2808 screw terminal accessory for use with NI SwitchBlock cards.

This installation guide describes how to install and connect signals to the NI TBX-2808 screw terminal accessory for use with NI SwitchBlock cards. INSTALLATION INSTRUCTIONS NI TBX-2808 Screw Terminal Accessory for the NI SwitchBlock This installation guide describes how to install and connect signals to the NI TBX-2808 screw terminal accessory for

More information

T775S Series 2000 Expansion Module

T775S Series 2000 Expansion Module T775S Series 000 Expansion Module INSTALLATION INSTRUTIONS PRODUT DESRIPTION The T775S008 Relay Expansion Module is a four relay device for use with the T775L007 and T775P00 Series 000 Electronic Stand-Alone

More information

SMI-100 Stack Monitoring Interface Installation & Operation Manual

SMI-100 Stack Monitoring Interface Installation & Operation Manual SMI-100 Stack Monitoring Interface Installation & Operation Manual Aquion Energy, Inc. 32 39th Street Pittsburgh, PA 15201 +1 412.904.6400 aquionenergy.com AQ-OP-00015_C 12.23.16 2016 Aquion Energy, Inc.

More information

hp uninterruptible power system r12000 xr models installation instructions

hp uninterruptible power system r12000 xr models installation instructions hp uninterruptible power system r000 xr models installation instructions Overview These instructions show how to install an uninterruptible power system (UPS). For detailed information about the UPS, refer

More information

SLATE. Digital I/O Module INSTALLATION INSTRUCTIONS R8001D4001

SLATE. Digital I/O Module INSTALLATION INSTRUCTIONS R8001D4001 SLATE Digital I/O Module R8001D4001 INSTALLATION INSTRUCTIONS Scan for more information Application SLATE brings configurable safety and programmable logic together into one single platform. The platform

More information

Dell Storage MD1400 Enclosures Hardware Owner's Manual

Dell Storage MD1400 Enclosures Hardware Owner's Manual Dell Storage MD1400 Enclosures Hardware Owner's Manual Notes, cautions, and warnings NOTE: A NOTE indicates important information that helps you make better use of your computer. CAUTION: A CAUTION indicates

More information

Replacing the PanelMate Power Pro 1785 Series, PanelMate epro 7585x-8 and 7685x-8 Series Backlight Assembly

Replacing the PanelMate Power Pro 1785 Series, PanelMate epro 7585x-8 and 7685x-8 Series Backlight Assembly Replacing the PanelMate Power Pro 1785 Series, PanelMate epro 7585x-8 and 7685x-8 Series Assembly Introduction The Replacement Kit provides a replacement backlight for the PanelMate Power Pro 1785 Series,

More information

PowerLogic High Density Metering System 1-Meter Enclosure

PowerLogic High Density Metering System 1-Meter Enclosure PowerLogic High Density Metering System 1-Meter Enclosure Installation Guide 63230-508-211A1 Safety information PowerLogic High Density Metering System 1-Meter Enclosure Important information Read these

More information

TB21. NO - Relay. Relay. Common - Relay. NC - Relay. Input J23. Ground TB22 TB23. NO - Relay Common - Relay NC - Relay Input Ground.

TB21. NO - Relay. Relay. Common - Relay. NC - Relay. Input J23. Ground TB22 TB23. NO - Relay Common - Relay NC - Relay Input Ground. NXT x.0 Wiring and Layout Diagrams. NXT-x I/O Module Shielded CAT- Cabling Shielded -Conductor Cabling total cable length 00 feet max (0 m) Brown/Green/Orange w/o Stripe Brown/Green/Orange with Stripe

More information

Hypercable injecteur HPOE - Industrial IEEE 802.3at Gigabit PoE Injector. User Manual. v.1.0 Jun Mail :

Hypercable injecteur HPOE -  Industrial IEEE 802.3at Gigabit PoE Injector. User Manual. v.1.0 Jun Mail : Industrial IEEE 802.3at Gigabit PoE Injector User Manual v.1.0 Jun-2011 FCC Warning This Equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15

More information

D-Link Switch User Manual. Table of Contents

D-Link Switch User Manual. Table of Contents Table of Contents About This Guide... 1 Terms/Usage... 1 Copyright and Trademarks... 1 Product Introduction... 2 Package Contents... 2 Product Overview... 2 Front Panel... 2 Rear Panel... 2 Indicator LEDs...

More information

LARGE S URGE-PROTECTOR S HELTER

LARGE S URGE-PROTECTOR S HELTER LARGE S URGE-PROTECTOR S HELTER The weather-resistant Large Surge-Protector Shelter (simply referred to as the shelter in this manual) provides protection from the elements for Surge Protectors (not included)

More information

Installation Job Aid for Avaya Virtual Services Platform 8400

Installation Job Aid for Avaya Virtual Services Platform 8400 Installation Job Aid for Avaya Virtual Services Platform 8400 Support Release 4.2 NN47227-305 Issue 01.06 June 2015 Go to the Avaya Support website at http://support.avaya.com for the most up-to-date documentation,

More information

Multi-Mount for Mac Pro " to 5.25" Drive Bay Converter Bracket. Assembly & Installation Manual

Multi-Mount for Mac Pro  to 5.25 Drive Bay Converter Bracket. Assembly & Installation Manual Multi-Mount for Mac Pro 2009-2010 3.5" to 5.25" Drive Bay Converter Bracket Assembly & Installation Manual Introduction 1 INTRODUCTION 1.1 System Requirements 1.1.1 Computer Requirements 1.1.2 Hard Drive

More information

This Datasheet for the IC660BBD110. Block 115Vac Input 16 Circuits.

This Datasheet for the IC660BBD110. Block 115Vac Input 16 Circuits. This Datasheet for the IC660BBD110 Block 115Vac Input 16 Circuits http://www.cimtecautomation.com/parts/p-14435-ic660bbd110.aspx Provides the wiring diagrams and installation guidelines for this GE Series

More information

Installation Job Aid for VSP 4850GTS

Installation Job Aid for VSP 4850GTS Installation Job Aid for VSP 4850GTS Notices Release 6.1.0.0 NN46251-308 Issue 02.01 November 2017 Notice paragraphs alert you about issues that require your attention. The following paragraphs describe

More information