Panel Meter Economical Panel Meter for Process, Temperature and Electrical Measurement

Size: px
Start display at page:

Download "Panel Meter Economical Panel Meter for Process, Temperature and Electrical Measurement"

Transcription

1 8 DN Multisignal Panel Meter Economical Panel Meter for Process, Temperature and Electrical Measurement DP20 TM DP20 meter shown smaller than actual size. OME s new multisignal panel meter delivers high-performance in a 8 DN size for panel mounts and integration in a wide range of applications. The DP20 accepts universal inputs, including thermocouple, RTD, process (m & Vdc), resistance, frequency and true RMS voltage and current. y configuration, it will work as an C and DC voltmeter (up to 600 V) and C and DC ammeter (up to 5 ) offering application flexibility for process control and industrial requirements. single universal power supply allows this unit to be suited for global use. The optional relays, analog output, and Modbus RTU serial communications provide customization, control and communication capability. dditional features of the economical DP20 panel meter include scaling, NEM 3 (P65) protection, and programmable decimal points. U Fast ccess Menu Front ey ccess to Modify the larm Setpoints and Max/Min Memory U External Control Function Contact at Multifunctional Terminal 5 (Second Scaling, Decimal Point Change, Hold the Reading Tare or ctivate the Max/Min Memory) U utomatic, Power Saving Eco Mode U larms or 2, ndependent, Configurable as Max/Min, with Setpoint and Hysteresis PPLCTONS U ssembly Line U Control Panel U Laboratory U Reading Offset Configure a Fixed Number of Counts to be dded to the Reading U Second Scaling Function Define Two Scalings for the Same Signal and Control (One is ctive with the External Control Option) U Recursive Display Filter for Noisy Signals and Configurable Steps for Minimum Predefined Changes on the Reading U Output and Control Options: or 2 Relay Outputs, nalog 4 to 20 m solated Output, Modbus RTU solated Serial Output U 5 Levels of rightness ntensity U Password Protection

2 Specifications Digits: 4 Reading: 9999 / -999 Decimal Point: Configurable LED Color: Red Digit Height: 4 mm (0.55") ccepted Signal Ranges: See tables at page 4 for more information C Voltages and C Currents: 600 Vac, 200 Vac, 20 Vac, 2 Vac, 200 mvac, 60 mvac, 5 ac, 20 mac (True RMS measure) (accepts phase-neutral and phase-phase measure) DC Voltages and DC Currents: ±600 Vdc, ±200 Vdc, ±20 Vdc, ±2 Vdc, ±200 mvdc, ±60 mvdc, ±5 dc, ±20 mdc Thermocouples:, J, E, N, L, R, S,, T and C (automatic cold junction compensation) Probes: Resistive Pt Probes: Pt00 with 2 and 3 wires, Pt500, Pt000 Resistive Ni Probes: Ni00, Ni200, Ni000 Resistive NTC Probes: See table at page 4 Resistive PTC Probes: Families TY-2, TY-20 and TY-220 Process: 4/20 m, 0/0 Vdc (+5 Vdc excitation voltage configurable at terminal 5) Resistances: Ranges 0/5 and 0/50 Potentiometers: With nominal values from 500 R up to 20 Frequency up to 00 Hz (minimum 5 Hz), Vac and ac ranges Thermal Drift Offset+Span: 50 ppm/ºc Readings: 3 readings/ second Refresh: 3 readings/ second Response Time: <300 msec. (0 % to 99 % of signal) Power U : 8 to 265 Vac/dc (isolated seconds) Output and Control Options or 2 Relays: analog output 4/20 m isolated Modbus RTU isolated serial output Protection: NEM 3 (P65) Consumption (Normal Mode): <.0 W (meter only) <2.5 W (meter with options) Consumption ( Eco Mode): <0.3 W (meter only) <.5 W (meter with options) Connections: Plug-in screw terminals Weight: <50 g (5.3 oz) Operation Temperature: 0 to 50 ºC (32 to 22ºF) 9 (3.58) (including terminal) 96 (3.78) Detail of the plug-in screw terminal. oth male and female terminals are included. 48 (.89) 44 (.74) Panel cut-out 92 (3.63) 6 (0.63) 75 (2.95) 8 (0.3) nternal Structure - for nput Range Selection Front filter Display module Optional modules Displays nternal jumpers Opt. Opt.2 Opt. Housing for signal range selection J H F E D C nput signal terminal not used can be stored in the following three no contact positions. Jumper for terminal 5 function selection J H F E D C 2

3 Connections and Rear View Option 2 (relay) Com. NO NC H Option 2 Option H C Option (relay) Com. NO NC C Option M (4/20 m) Vexc 4/20 m Common (active output -) (passive output C -C) Option S (Modbus RTU) Common Options Relay outputs Module and 2 Function relay output 3 contacts (NC, NO, Common) ~5 ac, ±5 dc C +Vdc / Phase (not connected) -Vdc / Neutral Vexc, Pt00 3 wires, pot+ external control neutral, 0 V, common ~Vac, ±Vdc, resistance, m, pot thermocouple+, Pt+, Ni+, PTC+, NTC+ Fuse nalog output Module M Function analog output isolated 4/20 m isolated 000 Vdc ~600 Vac, ~200 Vac ±600 Vdc, ±200 Vdc * Risk of electric shock. The E external control function shares terminal 4 with the common of the input signal connection. When measuring dangerous voltages ND using E external control contact, apply the appropriate protections to isolate the operator from dangerous voltages. s requested by security regulations EN-600-, add a protection fuse to the power line, with value: 250 m time-lag for power voltage > 50 Vac/dc 400 m time-lag for power voltage < 50 Vac/dc Modbus RTU output Module S Function Modbus RTU output bps, bps isolated 000 Vdc 3

4 nput Signal Ranges - Technical Specifications Vac ranges (Veff.) Oversignal Z in 800 Vac 2 M ~ 600 Vac 600 ~ 200 Vac Vac 2 M ~ 20 Vac <0.30% 50 Vac M ~ 2 Vac to -999 (up to 50 Hz) 00 Vac 00 ~ 200 mvac C 30 Vac 0 ~ 60 mvac 60.0 E 3 Vac M Vdc Ranges Oversignal Z in 800 Vdc 2 M ±600 Vdc 600 ±200 Vdc Vdc 2 M ±20 Vdc <0.20% 50 Vdc M ±2 Vdc to Vdc 00 ±200 mvdc C 30 Vdc 0 ±60 mvdc 60.0 E <0.25% 3 Vdc M ac ranges (eff.) Oversignal 7 ac max. 7 sec.) Z in ~ 5 ac mω <0.50% ~ 20 mac to -999 D (up to 50 Hz) 25 mac 4.7 R dc ranges Oversignal Z in ±5 dc ± <0.25% 7 dc 20 mω ±20 mdc ±20.00 to -999 D <0.5% (max. 7 sec.) 25 mdc 4.7 R Process Signals by Default Oversignal Z in 4/20 m 0/00.0 D <0.5% 25 m 4.7 R to * 0/0 Vdc 0/00.0 <0.20% 25 Vdc M *Place jumper at position -2 for +5 Vdc excitation voltage at terminal 5. Optionally, place jumper at position to work with external contact at terminal 5. NTC probes R25 (configurable)* Range of measure (% of reading) eta (configurable) 0 F, -60ºC to 50ºC <.5 % of reading * eta configurable (2000 to 5500). R25 configurable. Resistance measure from 00R to MR PTC probes Family TY-2 F TY-20 F, H, TY-220 F, H, Range in ºC (ºF) Total Error -55/50 (-67/302) < º Maximum oversignal is the maximum signal accepted by the instrument. Higher signal values may cause instrument damage. Lower values are not destructive but may be out of accuracy specifications. 4

5 nput Signal Ranges - Technical Specifications Thermocouples Range ºC (ºF) -00 to 350 (-48 to 2462) J -00 to 200 (-48 to 292) E E -00 to 000 (-48 to 832) N -00 to 300 (-48 to 2372) L -00 to 900 (-48 to 652) R 0 to 768 (32 to 324) S 0 to 768 (32 to 324) E, J T -00 to 400 (-48 to 752) C E 0 to 2300 (32 to 472) E, J 700 to 820 (292 to 3308) Total Error (Cold Junction ncluded) <3º <5º Pt and Ni Probes Range ºC (ºF) Total Error Current at Sensor Pt00 F, H, J to 700 (-328 to 292) < 900 u (3 wires) Pt00 F, H -200 to 700 (-328 to 292) < 900 u (2 wires) Pt500 F -50 to 630 (-238 to 66) <º < 90 u Pt000 F -90 to 630 (-30 to 66) < 90 u Ni00 F, H -60 to 80 (-76 to 356) < 900 u Ni200 F, H -60 to 20 (-76 to 248) < 900 u Ni000 F -60 to 80 (-76 to 356) < 90 u Resistance ranges 0 to F, H, 0 to to -999 F, (% of reading) <.5% of reading Potentiometers nominal value 500 R to 20 0/00.0 to <0.5% Frequency signals 5 Hz to 00 Hz 0/00.0 to -999 Vac or ac ranges (% reading) <0.5% of reading To Order Maximum oversignal is the maximum signal accepted by the instrument. Higher signal values may cause instrument damage. Lower values are not destructive but may be out of accuracy specifications. Model No. Description DP20 8 DN multisignal panel meter with universal 8/265 Vac/dc power supply DP20-8 DN multisignal digital panel meter with universal 8/265 Vac/dc power supply with relay output DP DN multisignal digital panel meter with universal 8/265 Vac/dc power supply with 2 relay outputs DP20-M 8 DN multisignal digital panel meter with universal 8/265 Vac/dc power supply with isolated 4 to 20 m analog output DP20-M-2 8 DN multisignal digital panel meter with universal 8/265 Vac/dc power supply with isolated 4 to 20 m analog output and relay output DP20-S 8 DN multisignal digital panel meter with universal 8/265 Vac/dc power supply with isolated Modbus RTU output DP20-S-2 8 DN multisignal digital panel meter with universal 8/265 Vac/dc power supply with isolated Modbus RTU output and relay output Comes complete with operator s manual. 5

User s Guide DP20. Economical Multisignal Meter for Process, Temperatures and Electrical signals. Shop online at omega.com

User s Guide DP20. Economical Multisignal Meter for Process, Temperatures and Electrical signals. Shop online at omega.com TM User s Guide Shop online at omega.com e-mail: info@omega.com For latest product manuals: www.omegamanual.info DP20 Economical Multisignal Meter for Process, Temperatures and Electrical signals U.S.A.

More information

User s Guide DP20. Economical Multisignal Meter for Process, Temperatures and Electrical signals. Shop online at omega.com

User s Guide DP20. Economical Multisignal Meter for Process, Temperatures and Electrical signals. Shop online at omega.com TM User s Guide Shop online at omega.com e-mail: info@omega.com For latest product manuals: www.omegamanual.info DP20 Economical Multisignal Meter for Process, Temperatures and Electrical signals U.S.A.

More information

L40 UNIVERSAL ANALOG INPUT DIGITAL PANEL METER OWNERS MANUAL

L40 UNIVERSAL ANALOG INPUT DIGITAL PANEL METER OWNERS MANUAL L40 UNIVERSAL ANALOG INPUT DIGITAL PANEL METER OWNERS MANUAL LAUREL Electronics Inc. 3183-G Airway Ave, Costa Mesa, CA, 92626, USA Tel: (714) 434-6131 Fax: (714) 434-3766 Website: www.laurels.com 1. ORDERING

More information

FEMA ELECTRÓNICA. Panel meter for process signals in ma and Vdc. Accepts both active and passive

FEMA ELECTRÓNICA. Panel meter for process signals in ma and Vdc. Accepts both active and passive Panel Meters Series M40 Panel meter 96x48mm FEMA ELECTRÓNICA Model M40-P for process signals ( ±20mA and ±10Vdc) Panel meter for process signals in ma and Vdc. Accepts both active and passive signals,

More information

Panel Meters Series M40 Model M40-A Amplicon.co m IT and Instrumentation for industry

Panel Meters Series M40 Model M40-A Amplicon.co m IT and Instrumentation for industry Panel Meters Series M40 Panel meter 96x48mm FEMA ELECTRÓNICA Model M40-A TrueRMS AC Voltages TrueRMS AC Currents Panel meter for TrueRMS measures of AC voltages and AC currents. Measure category in CAT-III

More information

12-36 VDC/12-24 VAC Power Option 4-Digit Display, 0.56 (14.2 mm) or 1.20 (30.5 mm)

12-36 VDC/12-24 VAC Power Option 4-Digit Display, 0.56 (14.2 mm) or 1.20 (30.5 mm) 4-20 ma & Relay Output Features 4-20 ma, ± 10 V, TC & RTD Inputs 12-36 VDC/12-24 VAC Power Option 4-Digit Display, 0.56 (14.2 mm) or 1.20 (30.5 mm) 24 VDC @ 200 ma Transmitter Power Supply Options Type

More information

96x48. gal/h. Digital panel meter 4½-digit DV4. Without setpoints. Sensor supply

96x48. gal/h. Digital panel meter 4½-digit DV4. Without setpoints. Sensor supply gal/h Digital panel meter 4½digit DV4 Without setpoints Sensor supply status 22/05/06 panelmeteranalog_gb.doc page 9 Digital panel meter Direct voltage Direct current gal/h Direct voltage, direct current

More information

PD765 TRIDENT. Trident Series Process & Temperature Meters.

PD765 TRIDENT. Trident Series Process & Temperature Meters. PD765 Trident Series Process & Temperature Meters TRIDENT PROCESS & Temp 4-20 ma, ± 10 V, TC & RTD Inputs 4-Digit Display, 0.56 (14.2 mm) or 1.20 (30.5 mm) Type 4X, NEMA 4X, IP65 Front 1/8 DIN Shallow

More information

SIGNAL CONVERTERS ELECTRONIC INSTRUMENTATION FOR INDUSTRY. Small catalogue. Tel. (+34)

SIGNAL CONVERTERS ELECTRONIC INSTRUMENTATION FOR INDUSTRY. Small catalogue.   Tel. (+34) SIGNAL CONVERTERS LARGE displays PANEL METERS ELECTRONIC INSTRUMENTATION FOR INDUSTRY Small catalogue 2013 www.fema.es Tel. (+34) 93.729.6004 info@fema.es SMALL CATALOguE 2013 ELECTRONIC INSTRUMENTATION

More information

PD765 TRIDENT. Trident Series Process & Temperature Meters.

PD765 TRIDENT. Trident Series Process & Temperature Meters. PD765 Trident Series Process & Temperature Meters TRIDENT PROCESS & Temp 4-20 ma, ± 10 V, TC & RTD Inputs 4-Digit Display, 0.56" (14.2 mm) or 1.20" (30.5 mm) Linear or Square Root with Low-Flow Cutoff

More information

Trident and Trident X2 Digital Process and Temperature Panel Meter

Trident and Trident X2 Digital Process and Temperature Panel Meter Sign In New User ISO 9001:2008 Certified Quality System Home Products Online Tools Videos Downloads About Us Store Contact Policies Trident and Trident X2 Digital Process and Temperature Panel Meter Products

More information

Small Catalog MANUFACTURING FOR INDUSTRIAL AUTOMATION DIGITAL PANEL METERS ISOLATORS & SIGNAL CONVERTERS YEARS YEARS.

Small Catalog MANUFACTURING FOR INDUSTRIAL AUTOMATION DIGITAL PANEL METERS ISOLATORS & SIGNAL CONVERTERS YEARS YEARS. MANUFACTURING FOR INDUSTRIAL AUTOMATION Small Catalog 2016-2017 45 YEARS 1969-2014 CE Product Q 5 Quality YEARS ISO9001 Extended Warranty DIGITAL PANEL METERS ISOLATORS & SIGNAL CONVERTERS Saelig Company,

More information

1/32-DIN TEMPERATURE CONTROLLER INSTALLATION, WIRING AND OPERATION MANUAL FORM 3882

1/32-DIN TEMPERATURE CONTROLLER INSTALLATION, WIRING AND OPERATION MANUAL FORM 3882 1/32-DIN TEMPERATURE CONTROLLER INSTALLATION, WIRING AND OPERATION MANUAL FORM 3882 This manual is intended for use in support of installation, commissioning and configuration of the 1/32-DIN Temperature

More information

User s manual. Programmable panel meter IPD

User s manual. Programmable panel meter IPD User s manual Programmable panel meter IPD Assembly Wall assembly: +0,5 +0,2 Window of 46 x 91 mm (2.5" x 3.5" ) Made with ABS (UL94-HB) -0-0 General cares in the installation The equipments must not be

More information

ProSense DPM2 Series. Digital Panel Meter. User Manual. for process, temperature and resistance input signals. Models: DPM2-AT-HL DPM2-AT-2R-HL

ProSense DPM2 Series. Digital Panel Meter. User Manual. for process, temperature and resistance input signals. Models: DPM2-AT-HL DPM2-AT-2R-HL User Manual ProSense DPM2 Series Digital Panel Meter for process, temperature and resistance input signals Models: DPM2-AT-HL DPM2-AT-2R-HL Scan or click the QR code for a series of Configuration and Programming

More information

The PM1000 series is a universal 4 digit LED plug-on display for transmitters with 4-20mA 2 wire output and fitted with DIN43650 connector.

The PM1000 series is a universal 4 digit LED plug-on display for transmitters with 4-20mA 2 wire output and fitted with DIN43650 connector. PM1000 SERIES PLUG-ON DISPLAY BRIGHT LED DISPLAY INDICATION RANGE -999 TO +9999 FITS TO DIN 43650 CONNECTOR PLUG-ON TO ANY TRANSMITTER WITH 4-20MA OUTPUT EASY TO SCALE ON SITE ROBUST DESIGN SET POINT OPTION

More information

SX90 Process Controller

SX90 Process Controller Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without

More information

ATR121 Controller with Dual Setpoint

ATR121 Controller with Dual Setpoint ATR121 Controller with Dual Setpoint Food industry Ovens/furnaces Refrigeration Sterilizers Environmental chambers Safety units Injection moulding Driers General Specifications Dimensions Supply Voltage

More information

LE ELECTRONICS Pvt. Ltd.

LE ELECTRONICS Pvt. Ltd. LE ELECTRONICS Pvt. Ltd. Monitoring Relays: LVM Line Voltage Monitors LCM - Line Current Monitors VMR Voltage Monitoring Relays CMR Current Monitoring Relays VCMR Voltage Current Monitoring Relays LFM

More information

Process & Temperature Digital Panel Meter

Process & Temperature Digital Panel Meter Process & Temperature Digital Panel Meter TRIDENT PD765 4-20 ma, ± 10 V, TC & RTD Inputs NEMA 4X, IP65 Front Shallow Depth Case 3.6" Behind Panel Universal Power Supply 85-265 VAC Two Relays Option with

More information

- SELF-TUNING PID ALGORITHM - INTUITIVE COLOR DISPLAY WITH TEXT MESSAGING - UNIVERSAL PROCESS AND TC/RTD INPUTS - MULTI- FUNCTION RAMP- DWELL/PROCESS

- SELF-TUNING PID ALGORITHM - INTUITIVE COLOR DISPLAY WITH TEXT MESSAGING - UNIVERSAL PROCESS AND TC/RTD INPUTS - MULTI- FUNCTION RAMP- DWELL/PROCESS ELK. ETK COMPACT BASIC CONTROL - SELF-TUNING PID ALGORITHM - INTUITIVE COLOR DISPLAY WITH TEXT MESSAGING - UNIVERSAL PROCESS AND TC/RTD INPUTS - MULTI- FUNCTION RAMP- DWELL/PROCESS TIMER - SOFT START OUTPUT

More information

LAUREL. Laureate RTD Temperature Panel Meter / Controller ELECTRONICS, INC. Features. Description. Specifications

LAUREL. Laureate RTD Temperature Panel Meter / Controller ELECTRONICS, INC. Features. Description. Specifications LAUREL ELECTRONICS, INC. Laureate RTD Temperature Panel Meter / Controller Features Factory calibrated for 100Ω platinum, 10Ω copper & 120Ω nickel RTDs 2, 3 or 4-wire connection with lead resistance compensation

More information

I-7520: RS-232 to RS-485. Input: RS-232 protocol Output:RS-485/RS-422 Speed: Self Tuner 'inside, auto switching baud rate, 300~ BPS

I-7520: RS-232 to RS-485. Input: RS-232 protocol Output:RS-485/RS-422 Speed: Self Tuner 'inside, auto switching baud rate, 300~ BPS I-7520 RS-232 to RS-485 Converter I-7510 RS-485 Repeater RS-232 RS-485 I-7000 SERIES Common Specifications Isolation voltage: 3000VDC Speed: 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115000 Dual watchdog

More information

TRACKER 220 SERIES. Digital Panel Indicators. A Complete Range of Universal Input Digital Panel Indicators for Temperature and Process Measurement

TRACKER 220 SERIES. Digital Panel Indicators. A Complete Range of Universal Input Digital Panel Indicators for Temperature and Process Measurement TRACKER 220 SERIES Digital Panel Indicators A Complete Range of Universal Input Digital Panel Indicators for Temperature and Process Measurement TRACKER 220 SERIES INDICATORS Universal Input Analogue Output

More information

The Tracker 220 Series A Complete Range of Universal Input Digital Panel Indicators for Temperature and Process Measurement

The Tracker 220 Series A Complete Range of Universal Input Digital Panel Indicators for Temperature and Process Measurement Acquisition Measurement Control The Tracker 220 Series A Complete Range of Universal Input Digital Panel Indicators for Temperature and Process Measurement TRACKER 220 SERIES INDICATORS Universal Input

More information

SINGLE-CHANNEL PROCESS INDICATOR series 8001

SINGLE-CHANNEL PROCESS INDICATOR series 8001 SINGLE-CHANNEL PROCESS INDICATOR series 8001 Analog Inputs - all inputs available in one unit - Pt100 RTD type DIN 43 760 or GOST 6651-78 (range from 0 to +600 C) - TC type: J - range from 0 to +600 C

More information

LAUREL ELECTRONICS, INC.

LAUREL ELECTRONICS, INC. LAUREL ELECTRONICS, INC. Laureate RTD Temperature Panel Meter / Controller Features Factory calibrated for 100Ω platinum, 10Ω copper & 120Ω nickel RTDs 2, 3 or 4-wire connection with lead resistance compensation

More information

DINALOG A 144 x 36 A1400 Light-Strip Indicator

DINALOG A 144 x 36 A1400 Light-Strip Indicator DINALOG A x 6 A00 Light-Strip Indicator -9-0-0 /.00 Front panel dimensions: x 6 mm Light-strip indicator with 7 high-contrast LEDs Red LED display color Digital display range for portrait format: 999 to

More information

D1000M SERIES FOR MODBUS SENSOR TO COMPUTER INTERFACE MODULES

D1000M SERIES FOR MODBUS SENSOR TO COMPUTER INTERFACE MODULES D1000M SERIES FOR MODBUS SENSOR TO COMPUTER INTERFACE MODULES D1000 FEATURES Complete sensor to RS-232/RS-485 interface. 500V rms analog input isolation. 15 bit measurement resolution. Continuous self-calibration;

More information

Temperature-Guard TG 50 Pt100/Pt Thermocouple J, K, N, S

Temperature-Guard TG 50 Pt100/Pt Thermocouple J, K, N, S Temperature-Guard TG 50 Pt100/Pt1000 - Thermocouple J, K, N, S Features M Input Pt100, Pt1000 and Thermocouples J, K, N, S M Measuring range programmable M Basic accuracy 0.1 % +/- 1 Digit M Simulator

More information

R1M-GH THERMOCOUPLE & DC INPUT MODULE MODEL. Remote I/O R1M Series. (16 points)

R1M-GH THERMOCOUPLE & DC INPUT MODULE MODEL. Remote I/O R1M Series. (16 points) Remote I/O R1M Series THERMOCOUPLE & DC INPUT MODULE (16 points) MODEL MODEL & SUFFIX CODE SELECTION R1MGH2T MODEL Modbus protocol I/O TYPE GH2 : Thermocouple or DC input, 16 points FIELD TERMINAL TYPE

More information

DIGITAL PANEL THERMOMETER

DIGITAL PANEL THERMOMETER Love Controls DIGITAL PANEL THERMOMETER LCI108-1x LCI108J-1x INSTRUCTION MANUAL EDITION: January 2001 INTRODUCTION TO THE LOVE CONTROLS LCI108 SERIES This manual does not constitute a formal agreement.

More information

THM501 PT100 MODBUS TEMPERATURE TRANSMITTER

THM501 PT100 MODBUS TEMPERATURE TRANSMITTER THM501 PT100 MODBUS TEMPERATURE TRANSMITTER INTRODUCTION The TekOn Electronics In Head 2-Wire Temperature Transmitters are specifically designed to meet the most rigorous requirements of operation in the

More information

Mini Digital Multimeter

Mini Digital Multimeter User's Guide Mini Digital Multimeter Model MN15 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Back to the Extech MN15/MN16 Series

More information

GUIDE PROGRAMMABLE PANEL METER M905

GUIDE PROGRAMMABLE PANEL METER M905 USER S GUIDE PROGRAMMABLE PANEL METER M905 Please read instructions carefully. 30727265 03/2018 Force Torque Pressure Acceleration - Standard Sensors and Custom Specials! MEAS France SAS, a TE Connectivity

More information

Series M. M40-P. Meter for process signals. User s Manual. Tel. (+34)

Series M. M40-P. Meter for process signals. User s Manual.   Tel. (+34) User s Manual ELECTRONICS FOR INDUSTRIAL AUTOMATION PANEL METERS. SIGNAL CONVERTERS. LARGE DISPLAYS Series M. M40-P Meter for process signals PANEL meters Panel meter for process signals in ma and Vdc.

More information

MIC-2 MKII, Multi-instrument DATA SHEET

MIC-2 MKII, Multi-instrument DATA SHEET MIC-2 MKII, Multi-instrument DATA SHEET Measurements All 3-phase AC measurements True RMS 4-Quadrant energy Power Quality Analysis Replaces analogue meters RS-485 Modbus RTU protocol TCP/IP Modbus (optional)

More information

/8 DIN Motorized Valve Controller

/8 DIN Motorized Valve Controller Data Sheet SS/_5 Boundless motorized valve controller no need for slidewire feedback; improves reliability Two sealed 5A control relays suitable for direct connection to the valve, reducing installation

More information

Digital Indicator Solutions

Digital Indicator Solutions Digital Indicator Solutions Loop-Powered Attachable Compact Attachable Loop-Powered Smart Compact System Loop-Powered Compact Smart System Intelligent Smart System "Intelligent" Options Dual & Display

More information

TC Type Range Conformity Error. J -210 C to +760 C (-347 F to F) ±0.09 C (±0.16 F) K -244 C to C (-408 F to F) ±0.1 C (±0.

TC Type Range Conformity Error. J -210 C to +760 C (-347 F to F) ±0.09 C (±0.16 F) K -244 C to C (-408 F to F) ±0.1 C (±0. LAUREL ELECTRONICS, INC. Laureate Thermocouple Panel Meter / Controller Features Factory calibrated for thermocouple types J, K, T, E, N, R, S Entire range of each thermocouple in one scale Highly accurate

More information

100mm Process Indicator Recorder

100mm Process Indicator Recorder Data Sheet SS/_3 100mm Process Indicator Recorder One or two pen continuous line 100mm recorder universal input for thermocouple, RTD, mv, ma and V Clear, 5-digit LED display high visibility, wide viewing

More information

User s Guide. LDB-RTU Meters for Modbus RTU. Shop online at omega.com. For latest product manuals:

User s Guide. LDB-RTU Meters for Modbus RTU. Shop online at omega.com.   For latest product manuals: TM User s Guide Shop online at omega.com e-mail: info@omega.com For latest product manuals: www.omegamanual.info LDB-RTU Meters for Modbus RTU omega.com info@omega.com U.S.A. Headquarters: Servicing North

More information

ProSense DPM3 Series Digital Panel Meter

ProSense DPM3 Series Digital Panel Meter User Manual ProSense DPM3 Series Digital Panel Meter for process, temperature and load cell input signals Models: DPM3-AT-H DPM3-AT-L DPM3-AT-2R-H DPM3-AT-2R-L DPM3-AT-4R-H DPM3-AT-4R-L DPM3-AT-A-H DPM3-AT-A-L

More information

UDC 1000 and UDC 1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS

UDC 1000 and UDC 1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS UDC 1000 and UDC 1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS EN0I-6041 12/99 PRODUCT SPECIFICATION SHEET OVERVIEW The UDC 1000 and UDC 1500 are microprocessor-based 1/16 DIN and 1/8 DIN controllers

More information

Modular Panel Meter Series EDM 35

Modular Panel Meter Series EDM 35 Modular Panel Meter Series EDM 35 CONTENTS Page 1. Introduction 2 1.1 Getting Started 2 1.2 Overall Description 3 1.3 Features 3 1.4 Block Schematic 4 2. Unit Description 4 2.1 Modules 4 2.2 Main Unit

More information

CONTENTS. Chapter 1...Description. Chapter 2...Installation. Chapter 3...Operation. Chapter 4...Calibration. Chapter 5...

CONTENTS. Chapter 1...Description. Chapter 2...Installation. Chapter 3...Operation. Chapter 4...Calibration. Chapter 5... CONTENTS Chapter 1...Description Chapter 2...Installation Chapter 3...Operation Chapter 4...Calibration Chapter 5.....Doric Viewer Chapter 6.Specifications Description Chapter 1 The Series 5000 is designed

More information

TRACKER 240 SERIES. Load Cell and Weighing Indicators. A Precision Measurement Instrument with Outstanding Features

TRACKER 240 SERIES. Load Cell and Weighing Indicators. A Precision Measurement Instrument with Outstanding Features TRACKER 240 SERIES Load Cell and Weighing Indicators A Precision Measurement Instrument with Outstanding Features TRACKER 240 SERIES INDICATORS Ratiometric Measurement Tare and Auto Transducer Excitation

More information

/8 DIN Universal Process Indicator

/8 DIN Universal Process Indicator Data Sheet SS/_ High visibility LED display the clearest view of your process status.% measurement accuracy precise indication of process measurement Analog and relay outputs as standard alarm and retransmission

More information

InBin-P Pressure switches from 5 Pa Pa

InBin-P Pressure switches from 5 Pa Pa InBin-P Pressure switches from 5 Pa...100 Pa Electrical, binary pressure or differential pressure switches with adjustable switch activation delay 24 VAC/DC supply voltage, potential free switching contact

More information

DMW. Digital Weighing Meter. Model Number Legend SALIENT FEATURES. Sensing

DMW. Digital Weighing Meter. Model Number Legend SALIENT FEATURES. Sensing Digital Meter Model Number Legend 1 2 3 1. Series 2. Output Type N: Indication Only R: 2 Relay Output M: 2 Relay Output + RS485 Modbus SALIENT FEATURES External Tare 96 x 48 Housing Dual Alarm Outputs

More information

JUMO Quantum PID100/PID200/PID300

JUMO Quantum PID100/PID200/PID300 Data sheet 702020 Page 1/12 JUMO Quantum PID100/PID200/PID300 Universal PID Controller Series Brief description The Quantum series is available in the three DIN formats 48 mm x 48 mm, 48 mm x 96 mm, and

More information

Digital Panel Meters Modular Indicator and Controller Type UDM35

Digital Panel Meters Modular Indicator and Controller Type UDM35 ISE, Inc 000 Royalton Rd. Cleveland, OH 4433 Tel: (440) 2373200 Fax: (440) 237744 http://iseinc.com Digital Panel Meters Modular Indicator and Controller Type UDM35 Front protection degree: IP67, NEMA4x

More information

High Voltage DC Meter

High Voltage DC Meter High Voltage DC Meter Javelin D PD644 0-300 VDC input NEMA 4X, IP65 front Scale in engineering units Sunlight readable LED display 4-20 ma analog output Two form C 3 A relays option RS-485 serial communications

More information

LAUREL. Laureate Digital Panel Meter for Process and Ratiometric Signals ELECTRONICS, INC. Features. Description

LAUREL. Laureate Digital Panel Meter for Process and Ratiometric Signals ELECTRONICS, INC. Features. Description LAUREL ELECTRONICS, INC. Laureate Digital Panel Meter for Process and Ratiometric Signals Features Reads process signals from ±200 mv to ±600V or ±2 ma to ±5A full scale Ratiometric mode for bridges and

More information

DINALOG A 96 x 24. Programmable quasi-analogue bar graph meters. Technical characteristics DINALOG A 96 x 24

DINALOG A 96 x 24. Programmable quasi-analogue bar graph meters. Technical characteristics DINALOG A 96 x 24 Bar graph displays For process control, automation, and laboratory applications Current, voltage, resistance, frequency and temperature Up to 0.5% resolution DINALOG A 96 x 24 Programmable quasi-analogue

More information

APPLICATION. Data acquisition Remote I/O I/O extension DESCRIPTION CONSTRUCTION

APPLICATION. Data acquisition Remote I/O I/O extension DESCRIPTION CONSTRUCTION RM 200 Modular I/O system open MODBUS Ethernet Plug-in I/O modules Suitable for CANopen/PROFIBUS-DP/MODBUS/Ethernet Modules for numerous sensors and signals 2, 4 or 8 channels, depending on module version

More information

Temperature Hawk HK35 & HK45 Series Advanced Digital Panel Meter

Temperature Hawk HK35 & HK45 Series Advanced Digital Panel Meter Temperature Hawk HK35 & HK45 Series Advanced Digital Panel Meter Easily Programmed from the Front Panel Software Functions Include: Password One or Two Set points Time Delay & Hysteresis Display Scaling

More information

DEIF A/S. MIC Multi-instrument G. Data sheet. Features. Accuracy. Measurements. Installation. Intelligent. Display. Communication DEIF A/S

DEIF A/S. MIC Multi-instrument G. Data sheet. Features. Accuracy. Measurements. Installation. Intelligent. Display. Communication DEIF A/S Multi-instrument 4921210107G Features Measurements All 3-phase AC measurements True RMS Replaces analogue meters Intelligent Suitable for all 3-phase network topologies Replaces transducers Accuracy U,

More information

Wall-/Pipe Mounted Universal Process Indicator

Wall-/Pipe Mounted Universal Process Indicator Data Sheet SS/_8 Wall-/Pipe Mounted Universal Process Indicator High visibility LED display the clearest view of your process status 0.1% measurement accuracy precise indication of process measurement

More information

INTRINSICALLY SAFE INSTRUMENTATION FOR HAZARDOUS AREAS

INTRINSICALLY SAFE INSTRUMENTATION FOR HAZARDOUS AREAS INTRINSICALLY SAFE INSTRUMENTATION FOR HAZARDOUS AREAS SHORT FORM 2002 SERIES D1000 Intrinsically Safe Galvanic Isolators SERIES D1000, for DIN Rail Mounting, provide the most simple and cost effective

More information

Mini Digital Multimeter Model MN15. User's Guide

Mini Digital Multimeter Model MN15. User's Guide Mini Digital Multimeter Model MN15 User's Guide Introduction Congratulations on your purchase of the Extech MN15 MultiMeter. The MN15 offers AC/DC Voltage, AC/DC Current, Resistance, Diode, and Continuity

More information

HIGH-VOLTAGE DC METER

HIGH-VOLTAGE DC METER HIGH-VOLTAGE DC METER Javelin D PD644 0-300 VDC input NEMA 4X, IP65 front Scale in engineering units Sunlight readable LED display 4-20 ma analog output Two form C 3 A relays option RS-485 serial communications

More information

C160 Wall-/Pipe Mounted Universal Process Indicator

C160 Wall-/Pipe Mounted Universal Process Indicator Data sheet DS/ EN Rev. I Wall-/Pipe Mounted Universal Process Indicator reliable process indicator, wherever it s needed High visibility LED display the clearest view of your process status 0.1% measurement

More information

General Specifications. P2-08THM Analog Input

General Specifications. P2-08THM Analog Input General Specifications Operating Temperature Storage Temperature Humidity Environmental Air Vibration Shock Field to Logic Side Isolation Heat Dissipation Enclosure Type Agency Approvals Module Keying

More information

Digital Panel Meters Modular signal s conditioner Type USC-DIN

Digital Panel Meters Modular signal s conditioner Type USC-DIN Digital Panel Meters Modular signal s conditioner Type DIN Linearization of V and A inputs up to 6 points Multiinput modular signal s conditioner 0.% RDG basic accuracy TRMS AC current and voltage measurements

More information

Laurel Electronics Customer Price List

Laurel Electronics Customer Price List Laurel Electronics 2017 Customer Price List Laurel Electronics, Inc. 3183-G Airway Ave., Costa Mesa, CA 92626-4611 USA Phone: (714) 434-6131 Fax: (714) 434-3766 E-mail: sales@laurels.com Website: www.laurels.com

More information

DM-918 OPERATIONS MANUAL AUTORANGING MULTIMETER

DM-918 OPERATIONS MANUAL AUTORANGING MULTIMETER DM-918 OPERATIONS MANUAL AUTORANGING MULTIMETER SAFETY INFORMATION The following safety information must be observed to ensure maximum personal safety during the operation of this meter: This meter is

More information

Remote I/O Modules EH-RIO2 Series

Remote I/O Modules EH-RIO2 Series Remote I/O Modules EH-RIO2 Series Fieldbus adapter: ProfiNET, EtherCAT, Modubus TCP / RTU, Profibus-DP, DeviceNet Separation of electronics module and terminal block for easy installation and maintenance

More information

DIGITAL PANEL THERMOMETER

DIGITAL PANEL THERMOMETER Love Controls DIGITAL PANEL THERMOMETER LCI108-2x LCI108J-2x INSTRUCTIONS MANUAL EDITION: February 2001 INTRODUCTION TO THE LOVE CONTROLS LCI108 SERIES This manual does not constitute a formal agreement.

More information

Safety Temperature Limiter TT-STL 50

Safety Temperature Limiter TT-STL 50 GmbH Postal address: House address Fon (+49) 0 22 42-8703-0 Postbox 1261 Löhestr. 37 Fax (+49) 0 22 42-8703-20 http: // www.tematec.de 53759 Hennef 53773 Hennef e-mail: team@tematec.de Safety Temperature

More information

Display and Monitoing Units

Display and Monitoing Units Display and Monitoing Units DISPLAY AND MONITOrING UNITS 13 The universal display unit HDA 5500 provides the means of visualizing and further processing the signals from our sensors. The unit is designed

More information

5B Series 16 Channel Backplane 5B01 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

5B Series 16 Channel Backplane 5B01 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM 5B Series 16 Channel Backplane 5B01 FEATURES Mix and Match 5B Series I/O Module Capability Factory Mutual (FM) Approved Approved for Use in Class I, Division2, Groups A, B, C, and D Locations. CE Certified:

More information

OPERATING INSTRUCTION

OPERATING INSTRUCTION OPERATING INSTRUCTION AUTORANGING MULTIMETER MAX Ω F C 10A MAX every 15 min. COM V SAFETY INFORMATION The following safety information must be observed to insure maximum personal safety during the operation

More information

MIC-2 Multi-instrument DATA SHEET

MIC-2 Multi-instrument DATA SHEET Measurements All 3-phase AC measurements True RMS 4-Quadrant energy Power Quality Analysis Replaces analogue meters RS-485 Modbus RTU protocol TCP/IP Modbus (optional) Profibus DP (optional) I/O modules

More information

S-14 S-14. Compact Digital Multimeter. Compact Digital Multimeter

S-14 S-14. Compact Digital Multimeter. Compact Digital Multimeter S-14 Compact Digital Multimeter S-14 Compact Digital Multimeter SAFETY INFORMATION The following safety information must be observed to insure maximum personal safety during the operation at this meter

More information

PowerFlex 40 Sample Specification

PowerFlex 40 Sample Specification PowerFlex 40 Sample Specification GENERAL REFERENCES REGULATORY REQUIREMENTS Designed to meet the following specifications: NFPA 70 - US National Electrical Code NEMA ICS 3.1 - Safety standards for Construction

More information

smart meters... 6 panel meters... 7 field displays... 8 display types loop powered displays TRANSMITTERS & CONVERTERS...

smart meters... 6 panel meters... 7 field displays... 8 display types loop powered displays TRANSMITTERS & CONVERTERS... 2 content DISPLAYS... 4 smart meters... 6 panel meters... 7 field displays... 8 display types... 10 loop powered displays... 12 TRANSMITTERS & CONVERTERS... transmitters... 15 converters... 18 serial data

More information

Digital Temperature Controllers MR301/302

Digital Temperature Controllers MR301/302 mikrorem d.o.o. m e r n o r e g u l a c i o n a o p r e m a Digital Temperature Controllers MR301/302 User's Manual doc. 0488A-01/12 "MIKROREM" d.o.o., Braće Spasić 4A, 32000 ČAČAK tel/fax: +381 (32) 370

More information

LAUREL. Laureate Digital Panel Meter for Load Cell & Microvolt Input ELECTRONICS, INC. Features. Description

LAUREL. Laureate Digital Panel Meter for Load Cell & Microvolt Input ELECTRONICS, INC. Features. Description Description LAUREL ELECTRONICS, INC. Features Laureate Digital Panel Meter for Load Cell & Microvolt Input 20, 50, 100, 250 & 500 mv ranges Span adjust from 0 to ±99,999, zero adjust from -99,999 to +99,999

More information

Dew point. Dew point set DS 400. Special features: Dew point set DS 400. Technical data DS 400. Technical data FA 410

Dew point. Dew point set DS 400. Special features: Dew point set DS 400. Technical data DS 400. Technical data FA 410 Dew point set DS 400 for stationary dew point monitoring of refrigeration or adsorption dryers. The touch screen graphic display enables an intuitive operation and shows the progress of the measured values.

More information

INSTRUCTIONS FOR MODEL 1000 DIGITAL PROCESS INDICATOR AND ALARM

INSTRUCTIONS FOR MODEL 1000 DIGITAL PROCESS INDICATOR AND ALARM INSTRUCTIONS FOR MODEL 1000 DIGITAL PROCESS INDICATOR AND ALARM LOVE CONTROLS DIVISION Dwyer Instruments, Incorporated PO Box 338 Michigan City, IN 46361-0338 (800) 828-4588 (219) 879-8000 FAX (219) 872-9057

More information

MIC-2 MKII & MIC-2 MKII DIN, Multi-instrument DATA SHEET

MIC-2 MKII & MIC-2 MKII DIN, Multi-instrument DATA SHEET & DIN, Multi-instrument DATA SHEET Measurements All 3-phase AC measurements True RMS 4-Quadrant energy Power Quality Analysis Replaces analogue meters RS-485 Modbus RTU protocol TCP/IP Modbus (optional)

More information

UNIVERSAL TEMPERATURE INDICATOR 2 TECHNICAL SPECIFICATIONS

UNIVERSAL TEMPERATURE INDICATOR 2 TECHNICAL SPECIFICATIONS T 96 UNIVERSAL TEMPERATURE INDICATOR INSTALLATION and OPERATION MANUAL SOFTWARE VERSION.x (includes R77 version) code 860F / edition 06/09 8 INSTALLATION Dimensions and cutout; panel mounting 05 0 08 96,5

More information

Temperature Measurement

Temperature Measurement Copyright 1999-2002. All rights reserved. Web design by Sullivan Creative -1000 to +3500 and -10000 to +35000 Count Thermocouple, RTD, and Thermistor Temperature Measurement in C or F without Recalibration

More information

Autoranging True RMS Multimeter User Manual

Autoranging True RMS Multimeter User Manual Autoranging True RMS Multimeter User Manual Please read this manual before switching the unit on. Important safety information inside. Contents Page 1. Safety Information... 4 2. Safety Symbols... 5 3.

More information

Cube67 - Modular I/O station

Cube67 - Modular I/O station Compact modules Cube67 DI16 C 8xM12 Cube67 DI8 C 4xM12 Cube67 DI8 C 8xM8 Digital inputs Art.-No. UL 56602 UL 56612 UL 56622 approx. 50 ma approx. ma Terminator integrated Configuration PIN 2 input/diagnostic

More information

OPERATING INSTRUCTION. Pen-Type Digital Multimeter

OPERATING INSTRUCTION. Pen-Type Digital Multimeter OPERATING INSTRUCTION Pen-Type Digital Multimeter International Safety Symbols This symbol, adjacent to another symbol or terminal, indicates the user must refer to the manual for further information.

More information

MXIO. Compact I/O module. Summary. Application Compact I/O module for data acquisition and HVAC control systems. Function

MXIO. Compact I/O module. Summary. Application Compact I/O module for data acquisition and HVAC control systems. Function MXIO Compact I/O module Summary The MXIO multiple I/O compact module is a microprocessor-controlled, communicative module with the I/O mix optimized for larger HVAC control applications. The module uses

More information

SINGLE-CHANNEL PROCESS CONTROLLERS & TEMP. DISPLAYS D3820/D3830 Series

SINGLE-CHANNEL PROCESS CONTROLLERS & TEMP. DISPLAYS D3820/D3830 Series The Digitec Series D3800 Panel Meters offer many features and performance capabilities to suit a wide range of industrial applications. The D3820 and D3830 are available in the ranges of 4-20mA, 0-10 VDC,

More information

PRODIS. PD-ADC Digital Process Meter for analog Sensors. Digital Process Meters. Datasheet

PRODIS. PD-ADC Digital Process Meter for analog Sensors. Digital Process Meters. Datasheet Digital Process Meters Digital Process Meter for analog Sensors Datasheet Copyright ASM GmbH Am Bleichbach 18-24 85452 Moosinning Germany The information presented in this data sheet does not form part

More information

H3 Series. Nanmac Corporation. Dual-Line 6-Digit Temperature Meter.

H3 Series. Nanmac Corporation. Dual-Line 6-Digit Temperature Meter. H3 Series Dual-Line 6-Digit Temperature Meter Temperature J, K, T, E, R, S, B, N, C Thermocouples 100 or 1000 Ω Platinum, 10 Ω Copper, 120 Ω Nickel RTDs 1 or 0.1 Resolution Averages up to 10 RTD Sensors

More information

PD Helios Dual-Line 6-Digit Temperature Meter. Actual Size Digit

PD Helios Dual-Line 6-Digit Temperature Meter.   Actual Size Digit PD2-7000 Helios Dual-Line 6-Digit Temperature Meter Actual Size Digit Temperature Large 1.80" Digits Dual-Line 6-Digit Display Readable from up to 100 Feet (30 Meters) Away Superluminous Sunlight Readable

More information

IN-uP4 Universal Input Indicator.

IN-uP4 Universal Input Indicator. IN-uP4 Universal Input Indicator. Installation Guide. IN-uP4 Installation Guide Index. Description. Page 3 Features. Page 3 Ordering Information. Page 3 Product Liability. Page 3 Specifications. Page 4

More information

The IQ240 panel mount load cell indicator is a precision digital indicator for load cell and strain gauge applications.

The IQ240 panel mount load cell indicator is a precision digital indicator for load cell and strain gauge applications. IQ240 Panel Mount Load Cell Indicator Data sheet English 1.01 Introduction The IQ240 panel mount load cell indicator is a precision digital indicator for load cell and strain gauge applications. The high

More information

West Instruments. The MLC compact multi-loop controller... MLC ends the control or integration compromise

West Instruments. The MLC compact multi-loop controller... MLC ends the control or integration compromise The MLC 9000+ compact multi-loop controller... MLC 9000+...ends the control or integration compromise Why the MLC 9000+? Use the MLC 9000+ as a discrete controller mounted behi either as a stand-alone

More information

Contents. Temperature & Process Measurement Indicators Setup Guide

Contents. Temperature & Process Measurement Indicators Setup Guide Contents Introduction... 2 Installation... 3 Connections... 5 Connecting the Sensor... 6 Powering the Instrument... 7 Operator Functions... 8 The Setup Menus... 9 Configuration Menu Map... 12 Menu Options...

More information

ESM H 77x35 DIN Size Heating Controller Digital, ON / OFF Temperature Controller

ESM H 77x35 DIN Size Heating Controller Digital, ON / OFF Temperature Controller Internal Buzzer ESM- 3711-H 77x35 DIN Size Heating Controller ESM-3711-H 77 x 35 DIN Size Digital, ON / OFF Temperature Controller - 3 Digits display - PTC Input or, J type Thermocouple Input or, K type

More information

Process displays For current and voltage

Process displays For current and voltage Features Voltage input TRMS-AC/DC up to 600 V Current input AC/DC 1 A, 5 A and shunt (precision resistor) 60 or 100 mv With 2 or 4 limits Display range can be linearised Min, Max, Hold functions 4 20 ma

More information

AMC 8 & IOC 8T. Analog Monitoring Card Type AMC 8 and Input / Output Card Type IOC 8T FEATURES

AMC 8 & IOC 8T. Analog Monitoring Card Type AMC 8 and Input / Output Card Type IOC 8T FEATURES Analog Monitoring Card Type AMC 8 and Input / Output Card Type IOC 8T FEATURES Two cards providing 8 channels of temperature and process monitoring for VM 600 systems 8 channels of software selectable

More information

Digital Clamp Meter User Manual

Digital Clamp Meter User Manual Compact AC, AC/DC Digital Clamp Meter User Manual Please read this manual before switching the unit on. Important safety information inside. Contents 1.Safety... 3 2.Safety Notes... 3 3.Warnings... 3 4.Cautions...

More information