HomeWorks Remote Power Feed-Through Panels

Size: px
Start display at page:

Download "HomeWorks Remote Power Feed-Through Panels"

Transcription

1 power feed-through panels are available in two different sizes, each of which may be either surface-mounted or recess-mounted, in an electrical closet or other equipment room. The number of remote power panels and the types of components within them may be specified to fit the size, lighting plan, and design of a home. power panels may be distributed throughout the home for added flexibility during installation of the line-voltage wiring. power feed-through panels may contain HomeWorks remote power modules and HomeWorks processors and module interfaces. A few of the possible configurations are shown below. Five- Feed-Through Panel (Model # HWI-PNL-5) Accommodates the following combination of components: s (up to 5) Eight- Feed-Through Panel (Model # HWI-PNL-8) Accommodates one of the following combinations of components: Up to 5 remote power modules Note: HWI-PNL-5 cannot house a HomeWorks Processor s s or Supply Processor or interface Up to 2 processors or interfaces, 2 power supplies, and/or wire landing boards (WLB) Up to 8 remote power modules 1 Up to 8 remote power modules 1 1 Filter choke assembly or 0-10V modules may be installed in place of module 8. 1 Lutron 24/7 Technical Support

2 Model Number Capacity Regulatory Approvals Environment Cooling Heat Generated Fully Loaded Line-Voltage Connections DIN Rail Terminal Ground Bar Terminals Miswire Protection Mounting Dimensions Construction Shipping Weight HWI-PNL-8: Eight- Feed-Through Panel. Eight RPMs (HW-RPM-4A, HW-RPM-4U, HW-RPM-4FSQ, HW-RPM-4M, and HW-RPM-4R) in any combination and one module interface and one HomeWorks Processor, Supply, and/or wire landing board (WLB). See Fig. 3, pg. 3. UL, CSA, NOM Ambient operating temperature : 0 C to 40 C, 32 F to 104 F Ambient operating humidity: 0-90% humidity, non-condensing. Indoor use only. Passive cooling. Mount in a place where the vented cover will not be blocked. 750 BTUs per hr. maximum. Use copper wire only, supply conductors 60 / 75 C. DIN rail-mounted terminal blocks provided for line-voltage remote power module wiring MI and power supply. Terminal blocks should be tightened to 3.5 to 5.0 in.-lbs. (0.40 to 0.57 N m). See Fig. 2, pg. 3. Terminal blocks will accept one 18 to 10 AWG (1.0 to 2.5 mm 2 ) wire or two 18 to 16 AWG (1.0 to 1.5 mm 2 ) wires. Terminal blocks should be tightened to 3.5 to 5.0 in.-lbs. (0.40 to 0.57 N m). All terminal blocks are shipped with bypass jumpers installed. After verifying that each circuit is wired correctly, remove the bypass jumpers for system operation. 24 ground termination points. All terminal blocks are shipped with bypass jumpers installed. May be surface-mounted or flush-mounted. Panel fits between standard 16 in (406 mm) on-center stud framing. When flush mounting, to accomodate the depth of the panel in (10.5 cm) use 2x6 framing. If 2x4 framing is used the drywall must be built out or a frame must be constructed. Panel must be mounted vertically (+/- 7 degrees from vertical). Allow at least 12 in (30 cm) air space at top and bottom and a minimum of 12 in (30 cm) clearance in front of panel, or allow air space as required by local codes (whichever is greater). power panels will hum slightly and internal relays will click while in use. Mount where such noise is acceptable. Mount the panel so that line-voltage wiring will be at least 6 feet (1.8 m) from audio or electronic equipment and its wiring in (36.5 cm) x 59 in (150 cm) x in (10.5 cm) See Fig. 1, pg. 3. Enclosure: 16-gauge galvanized sheet metal (unpainted). Cover: Painted (black) metal cover with ventilation holes. Cover is attached using eight phillips-head screws. 25 lbs. (11.4 kg) without RPMs 2 Lutron 24/7 Technical Support

3 2 1 2 in (6 cm) 3/8 in (1 cm) 8 in (20 cm) 3/8 in (1 cm) Preferred Wiring Entry in (106 cm) 59 in (150 cm) 5/16 in dia. (8 mm) 5/8 in dia. (16 mm) Keyholes for surface mounting Locations (8 max.) Terminal Up -7º +7º in (37 cm) 11 in (22 cm) Mount Panel Vertically Screws for recess mounting in (38.5 cm) in (36.5 cm) Note: The panel is in (10.5 cm) deep past cover mounting tabs. Figure 1 Panel Dimensions and Mounting Alternate Wiring Entry Control Wiring Entry (NEC Class 2) Figure 2 Wiring Entry s s or Supply Processor or interface Up to 2 processors or interfaces, 2 power supplies, and/or wire landing boards (WLB) Up to 8 remote power modules 1 Up to 8 remote power modules 1 1 Filter choke assembly or 0-10V modules may be installed in place of module 8. Figure 3 Panel Configurations 3 Lutron 24/7 Technical Support

4 Model Number Capacity Regulatory Approvals Environment Cooling Heat Generated Fully Loaded Line-Voltage Connections DIN Rail Terminal Ground Bar Terminals Miswire Protection Mounting Dimensions Construction Shipping Weight HWI-PNL-5: Five- remote power feed-through panel. Five RPMs (HW-RPM-4A, HW-RPM-4U, HW-RPM-4FSQ, HW-RPM-4M, and HW-RPM-4R) in any combination and one module interface. See Fig. 2, pg. 5. UL, CSA, NOM Ambient operating temperature : 0 C to 40 C, 32 F to 104 F Ambient operating humidity: 0-90% humidity, non-condensing. Indoor use only. Passive cooling. Mount in a place where the vented cover will not be blocked. 475 BTUs per hr. maximum. Use copper wire only, supply conductors 60 / 75 C. DIN rail-mounted terminal blocks provided for line-voltage remote power module wiring, MI and power supply. Terminal blocks should be tightened to 3.5 to 5.0 in.-lbs. (0.40 to 0.57 N m). See Fig. 2, 3 pg. 5. Terminal blocks will accept one 18 to 10 AWG (1.0 to 2.5 mm 2 ) wire or two 18 to 16 AWG (1.0 to 1.5 mm 2 ) wires. Terminal blocks should be tightened to 3.5 to 5.0 in.-lbs. (0.40 to 0.57 N m). All terminal blocks are shipped with bypass jumpers installed. After verifying that each circuit is wired correctly, remove the bypass jumpers for system operation. 24 ground termination points. All terminal blocks are shipped with bypass jumpers installed. May be surface-mounted or flush-mounted. Panel fits between standard 16 in (406 mm) on-center stud framing. Panel must be mounted vertically (+/- 7 degrees from vertical). Allow at least 12 in (30 cm) air space at top and bottom and a minimum of 12 in (30 cm) clearance in front of panel, or allow air space as required by local codes (whichever is greater). power panels will hum slightly and internal relays will click while in use. Mount where such noise is acceptable. Mount the panel so that line-voltage wiring will be at least 6 feet (1.8 m) from audio or electronic equipment and its wiring in (36.5 cm) x 32 in (81 cm) x in (9.8 cm) See Fig. 1, pg. 5. Enclosure: 16-gauge galvanized sheet metal (unpainted). Cover: Painted (black) metal cover with ventilation holes. Cover is attached using six phillips-head screws. 18 lbs. (8.6 kg) without RPMs 4 Lutron 24/7 Technical Support

5 in (36.5 cm) 7 in (18 cm) 5/16 in dia. (8 mm) Preferred Wiring Entry 32 in (81 cm) 29 in (74 cm) 5/8 in dia. (16 mm) Keyholes for surface mounting Up -7º +7º Screws for recess mounting in (38.54 cm) Note: The panel is in (9.8 cm) deep past cover mounting tabs. Mount Panel Vertically in (19 cm) Figure 1 Panel Dimensions and Mounting Alternate Wiring Entry Figure 2 Wiring Entry Control Wiring Entry (IEC PELV/NEC CLASS 2) Terminal Locations (5 max) HWI-MI Up to 5 s Figure 3 Panel Configuration 5 Lutron 24/7 Technical Support

Wallbox Power Module. 4/8 Series Remote Dimming Controls Grafik Eye /WPM Link N/A INTRODUCTION SPECIFICATION & DESIGN FRONT ROOM BACK ROOM APPENDIX

Wallbox Power Module. 4/8 Series Remote Dimming Controls Grafik Eye /WPM Link N/A INTRODUCTION SPECIFICATION & DESIGN FRONT ROOM BACK ROOM APPENDIX Wallbox Power Module 4/8 Series Remote Dimming Controls Grafik Eye /WPM Link N/A W a l l b o x P o w e r M o d u l e (hwi-wpm-6d-120) HomeWorks Wallbox Power Modules (WPM) control six independent zones

More information

Power Boosters and 120 V Interfaces

Power Boosters and 120 V Interfaces Power Boosters and Interfaces 4/8/ Wireless Series Power Interfaces N/A N/A Power Boosters and Interfaces work with specific load types and/or increase the zone capacity of Wired Vareo Local Lighting Controls,

More information

HomeWorks QS Processor

HomeWorks QS Processor product specifications 369376d 06.03.15 The processor provides control and communication to system components. The Ethernet links allow communication to the software, integration with third party systems

More information

Back Room Equipment INTRODUCTION SPECIFICATION & DESIGN FRONT ROOM BACK ROOM APPENDIX

Back Room Equipment INTRODUCTION SPECIFICATION & DESIGN FRONT ROOM BACK ROOM APPENDIX Back Room Equipment http://resi.lutron.com Technical Support: product@lutron.com 89 P5 Processors HomeWorks processors comprise the major communication hub of a HomeWorks system. Each processor has communication

More information

HomeWorks QS Processor

HomeWorks QS Processor product specifications 369-376 The processor provides control and communication to system components. The Ethernet links allow communication to the software, integration with third party systems and communication

More information

Sivoia QS Wireless Smart Panel

Sivoia QS Wireless Smart Panel Sivoia QS Wireless 085355b 1 0.16.17 The Sivoia QS Wireless simplifies wiring and organizes installations with multiple Sivoia QS Wireless window treatments. The Sivoia QS Wireless is designed to be hardwired

More information

UL Listed Retrofit Solution for Savant-LiteTouch Systems 1.0 Overview

UL Listed Retrofit Solution for Savant-LiteTouch Systems 1.0 Overview UL Listed Retrofit Solution for Savant-LiteTouch Systems 1.0 Overview This application note demonstrates a retrofit solution for centralized Savant/LiteTouch Lighting systems involving a HomeWorks QS system.

More information

10-Output Configurable Smart Panel

10-Output Configurable Smart Panel 10-Output The 10-Output simplifies wiring and organizes installations with multiple Sivoia QS window treatments and other system devices and interfaces. 085593a 1 11.02.17 WIN-PS-5CC-R The 10-Output is

More information

Quantum Light Management Hub (QP3) for Quantum Select

Quantum Light Management Hub (QP3) for Quantum Select for Select The Quantum provides a centralized connection point for Lutron power panels and QS devices. 369423f 1 10.06.16 Features Designed to control, manage, and monitor any Energi Savr NodeTM units,

More information

Installation and Maintenance

Installation and Maintenance CHAPTER 4 Installation and Maintenance Revised: April 19, 2010, Introduction This chapter explains how to install a SCE 1000 platform in a rack or in a general tabletop or workbench installation. Additionally,

More information

Junos WebApp Secure 5.0 Hardware Guide

Junos WebApp Secure 5.0 Hardware Guide Junos WebApp Secure 5.0 Hardware Guide Junos WebApp Secure 5.0 Hardware Guide This document contains a specification for the MWS1000 hardware appliance, as well as instructions for installation into a

More information

Dual-Feed 80A Auto Low Voltage Disconnect Panel - 80LVD02

Dual-Feed 80A Auto Low Voltage Disconnect Panel - 80LVD02 Dual-Feed 80A Auto Low Voltage Disconnect Panel - 80LVD02 User Manual 1.1 Overview Telect s 80A, -48 Vdc Low-Voltage Disconnect (LVD) panel is a rack-mounted component with coil-operated contactors. These

More information

EcoSystem to 0 10 V- Interface

EcoSystem to 0 10 V- Interface to Interface to Interface 369537i 1 03.22.19 The to Interface provides a control gateway from an link to a compatible lighting device, typically an ED driver. It allows for individual addressing of the

More information

Switching Power Supply S82J. Ordering Information. Open-Frame, Covered-Frame, or Enclosed-Frame Type with Capacity Up to 600 W

Switching Power Supply S82J. Ordering Information. Open-Frame, Covered-Frame, or Enclosed-Frame Type with Capacity Up to 600 W Switching Power Supply Open-Frame, Covered-Frame, or Enclosed-Frame Type with Capacity Up to 600 W Models range from 10 to 600 W UL 508 approval on 100-W 150-W, 300-W, and 600-W models Wide range of output

More information

CS XL XM. EcoSystem Bus Supply

CS XL XM. EcoSystem Bus Supply EcoSystem An EcoSystem lighting network containing more than one ballast, module, or driver requires an EcoSystem. This supply powers one or two independent EcoSystem buses with up to 64 ballasts or ballast

More information

Voltage Current Front-mounting bracket

Voltage Current Front-mounting bracket Switching Power Supply S8PS Compact DIN-Rail Mounting Industrial Power Supplies with Capacities Up to 600 W Models range from 0 W to 600 W. Universal input: voltage range 0 to 240 VAC. Power Factor Correction

More information

QuantumR Light Management Hub

QuantumR Light Management Hub Quantum 369375e 1 04.02.2015 QuantumR Light Management Hub The Quantum light management hub provides a centralized connection point for Lutron EcoSystem digital ballast modules, Lutron power panels, GRAFIK

More information

QSE-CI-DMX Control Interface

QSE-CI-DMX Control Interface Control Interface The performs different functions depending on the system in which it is operating. The channels (maximum of 32) are mapped to HomeWorks zones and can be programmed as 1-channel lighting,

More information

QuantumR Light Management Hub (QP2)

QuantumR Light Management Hub (QP2) Quantum 369375f 1 11.05.15 QuantumR Hub (QP2) The Quantum light management hub provides a centralized connection point for Lutron EcoSystem digital ballast modules, Lutron power panels, and QS devices

More information

Control different load types with one device

Control different load types with one device Multipurpose Controllers DMC2 Multipurpose Modular Controller Control different load types with one device The Philips Dynalite DMC2 provides multichannel control via two interchangeable output modules.

More information

Free Energy Band RCC30U Room Temperature Controller for Four-pipe Fan Coil Unit

Free Energy Band RCC30U Room Temperature Controller for Four-pipe Fan Coil Unit Document No. 155-324 Free Energy Band RCC30U Room Temperature Controller for Four-pipe Fan Coil Unit Description Features Application Product Number Room temperature controller for four-pipe fan coil units.

More information

PHS Series. PowerHUBB Node - Satellite

PHS Series. PowerHUBB Node - Satellite PHS Series PowerHUBB Node - Satellite Project Name NETWORK Catalog No. Date The Hubbell Control Solutions' (HCS) PowerHUBB node provides power distribution architecture and data connectivity to create

More information

USER MANUAL INSTALLATION MANUAL. Isolation transformers. ITR Isolation Transformer 7000 W 230V/32A

USER MANUAL INSTALLATION MANUAL. Isolation transformers. ITR Isolation Transformer 7000 W 230V/32A USER MANUAL INSTALLATION MANUAL Isolation transformers ITR000702000 Isolation Transformer 7000 W 230V/32A Victron Energy B.V. The Netherlands General phone: +31 (0)36 535 97 00 Customer support desk: +31

More information

MicroTech II TM Remote I/O Panel Installation Manual

MicroTech II TM Remote I/O Panel Installation Manual Installation Manual IM 783-0 MicroTech II TM Remote I/O Panel Installation Manual Group: Controls Part Number: IM 783-0 Date: February 2004 Supersedes: New 2004 McQuay International Page 2 IM-783 Table

More information

15U Wall-Mount Server Rack Cabinet - 20 in. Deep - Hinged

15U Wall-Mount Server Rack Cabinet - 20 in. Deep - Hinged 15U Wall-Mount Server Rack Cabinet - 20 in. Deep - Hinged Product ID: RK1520WALHM This 15U server or network rack cabinet lets you mount your EIA-310 compliant equipment to the wall, in a secure enclosure

More information

Engine Control Unit, ECU 100 Engine control Engine monitoring and protection Easy-to-read graphical display Integrated emulation software solution

Engine Control Unit, ECU 100 Engine control Engine monitoring and protection Easy-to-read graphical display Integrated emulation software solution DATA SHEET Engine Control Unit, ECU 100 Engine control Engine monitoring and protection Easy-to-read graphical display Integrated emulation software solution DEIF A/S Frisenborgvej 33 DK-7800 Skive Tel.:

More information

Energi Savr Node with DALI for Quantum

Energi Savr Node with DALI for Quantum Energi Savr Node Digital Fixture Controller - CPN6916 Energi Savr Node with for Quantum 369794c 1 08.25.17 The Energi Savr Node family is a group of intelligent, modular products for the control of lighting

More information

2G Engine Installation

2G Engine Installation Issue 3, April 2015 2G Engine Installation General The Redwood engine powers and communicates with Redwood gateways, sensors, and wall switches. The engine offers sophisticated controls that significantly

More information

PACSystems RX7i IC698CHS009/119

PACSystems RX7i IC698CHS009/119 January 2010 The RX7i rack can be used for all RX7i CPU and I/O configurations, Series 90-70 I/O, and VME modules. Backplane connectors are spaced on 0.8" (20.3mm) centers to accommodate single-width RX7i

More information

Hassle-free equipment installation

Hassle-free equipment installation 22U 36in Knock-Down Server Rack Cabinet with Casters StarTech ID: RK2236BKF This server rack provides 22U of storage space in a sleek secure cabinet for storing EIA-310 compliant 19 rackmount devices such

More information

HomeWorksR QS 1-Link Processor

HomeWorksR QS 1-Link Processor product specifications 36905a 2.3.6 HomeWorksR QS -Link rocessor The HomeWorksR QS processor provides control and communication to HomeWorksR QS system components. The Ethernet link allows communication

More information

SIEMENS HEALTHCARE INTEGRATED ELECTRICAL CABINET

SIEMENS HEALTHCARE INTEGRATED ELECTRICAL CABINET Product Data Sheet Technical Publications SIEMENS HEALTHCARE INTEGRATED ELECTRICAL CABINET for ARTIS Q / Q.ZEN / ZEE BIPLANE IECAX480V225A Main Disconnect Panel Bevco Engineering Company, Inc. CONFIDENTIAL

More information

SLATE. Digital I/O Module INSTALLATION INSTRUCTIONS R8001D4001

SLATE. Digital I/O Module INSTALLATION INSTRUCTIONS R8001D4001 SLATE Digital I/O Module R8001D4001 INSTALLATION INSTRUCTIONS Scan for more information Application SLATE brings configurable safety and programmable logic together into one single platform. The platform

More information

ZBRN1 access point- 2 RJ V AC/DC-4 displays-5 LEDs-Eth-Modbus-wireless radio

ZBRN1 access point- 2 RJ V AC/DC-4 displays-5 LEDs-Eth-Modbus-wireless radio Characteristics access point- 2 RJ45-24..240V AC/DC-4 displays-5 LEDs-Eth-Modbus-wireless radio Product availability : Stock - Normally stocked in distribution facility Price* : 400.00 USD Main Range of

More information

HomeWorks QS Visor Controls

HomeWorks QS Visor Controls The HomeWorks QS Visor Controls allow lights, shades / draperies, and other equipment to be controlled from the car with just a touch of a button on a Visor Control Transmitter or a HomeLink compatible

More information

Installation RA5112-C-16A-C20. Basic Rack Power Distribution Unit

Installation RA5112-C-16A-C20. Basic Rack Power Distribution Unit Installation RA5112-C-16A-C20 Basic Rack Power Distribution Unit Contents Before You Begin........................1 Safety and grounding information..........1 How to Install the Rack PDU...............2

More information

VL BPC MINI. A configurable industrial computer platform. Data sheet 2930_en_F. 1 Description. 2 Features

VL BPC MINI. A configurable industrial computer platform. Data sheet 2930_en_F. 1 Description. 2 Features A configurable industrial computer platform Data sheet 90_en_F Description PHOENIX CONTACT 0-08- Features The VL BPC MINI is an embedded box PC and is part of the Valueline family of industrial computers.

More information

BTU-4D/BTU-4D-I Digital Temperature Unit & Sensors. Installation and Operation Manual

BTU-4D/BTU-4D-I Digital Temperature Unit & Sensors. Installation and Operation Manual BTU-4D/BTU-4D-I Digital Temperature Unit & Sensors Installation and Operation Manual BTU-4D/BTU-4D-I Installation and Operation Manual Rev E Table of Contents Introduction... 1 TEMP OUTDOOR Sensor... 1

More information

Custom Controller Installation Instructions

Custom Controller Installation Instructions MODEL CUSTOM CONTROLLER HARDWARE CODE MAX ALLOWABLE AMBIENT TEMP: 70 C (158 F) THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES. OPERATION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS: 1) THIS DEVICE MAY

More information

PLC Racks IC697CHS782/783

PLC Racks IC697CHS782/783 5 1 PLC Racks IC697CHS782/783 (IC697CHS782/783) datasheet Features Accepts 3rd Party VME modules which require 0.8 spacing. Accepts all IC697 PLC module types. Rear mount rack mounts in a 10 (254 mm) deep

More information

Article No. 6GK59230PS003AA2 6GK59240PS001AA2 Product Name. Power Supply SCALANCE PS924 PoE Input: 120/230V AC; Output: 54V/ 1.

Article No. 6GK59230PS003AA2 6GK59240PS001AA2 Product Name. Power Supply SCALANCE PS924 PoE Input: 120/230V AC; Output: 54V/ 1. Product Name Type of power supply Electrical data Input Waveform of the input Supply Power Supply SCALANCE PS924 PoE Input: 120/230V AC; Output: 54V/ 1.6A DC; NEC Class 2 single-phase AC Power Supply SCALANCE

More information

PanelView Plus/VersaView CE Terminals and Display Modules

PanelView Plus/VersaView CE Terminals and Display Modules Installation Instructions PanelView Plus/VersaView CE Terminals and Display Modules (Catalog Numbers 2711P-xxxxxx, 6182H-xxxxxx) English Inside: Overview...2 For More Information...2 Modular Components...3

More information

S66 Series Electronic Fan Speed Control

S66 Series Electronic Fan Speed Control FANs 121, 125, 1628.3 Product/Technical Bulletin S66 Issue Date 0918 S66 Series Electronic Fan Speed Control The S66 Series Electronic Fan Speed Control is designed to modulate the speed of single-phase,

More information

Site Preparation CHAPTER

Site Preparation CHAPTER CHAPTER 3 Site Preparation This chapter describes the steps to take and the considerations you should keep in mind prior to installing the modules in an open rack. It also contains information that applies

More information

Installation Job Aid for Ethernet Routing Switch 3600 Series

Installation Job Aid for Ethernet Routing Switch 3600 Series Installation Job Aid for Ethernet Routing Switch 3600 Series Notices NN47213-303 Issue 03.01 November 2017 Notice paragraphs alert you about issues that require your attention. Following are descriptions

More information

Surge Protective Devices. STV25K Series. Instruction Manual

Surge Protective Devices. STV25K Series. Instruction Manual Surge Protective Devices STV25K Series Instruction Manual Contents 1.0 Installation & Operation... 4 1.1 Environment... 4 1.2 Mechanical Dimensions... 4 1.3 DIN Rail Mounting... 5 1.4 Supplemental Enclosures...

More information

DIN Rail. user manual Models , & INT /503556/ UM

DIN Rail. user manual Models , & INT /503556/ UM DIN Rail Power Supply user manual Models 503549, 503556 & 503563 INT-503549/503556/503563-UM-0208-01 Thank you for purchasing the INTELLINET NETWORK SOLUTIONS DIN Rail Power Supply, Model 503549 (45 W

More information

Page Housing Plastic Metal Mounting DIN Rail or surface mount Panel or bracket mount Wattage Range 10W to 240W 7.5W to 240W 10W to 300W

Page Housing Plastic Metal Mounting DIN Rail or surface mount Panel or bracket mount Wattage Range 10W to 240W 7.5W to 240W 10W to 300W Selection Guide Selection Guide PS5R Slim Line PS5R PS3L Operator Interfaces Communication & Networking PLCs NEW Models Appearance Automation Software Page 107 113 118 Housing Plastic Metal Mounting DIN

More information

Savant Call Server: SCS-3000

Savant Call Server: SCS-3000 The Savant Call Server (SCS-3000) is a key communications building block in a Savant system. The Savant Call Server allows you to make panel-topanel calls from any intercom-ready ios devices (iphone, ipod

More information

REDUNDANCY MODULE TSP-REM360 AND TSP-REM600

REDUNDANCY MODULE TSP-REM360 AND TSP-REM600 REDUNDANCY MODULE TSP-REM360 AND TSP-REM600 Operating Instructions Seite 1 Dimensions drawings: TSP-REM360 Weight: 0.882lb Gewicht: 0.40kg Seite 2 Dimensions drawings: TSP-REM600 Bottom view Top view Side

More information

MicroTech II Remote I/O Panel Installation Manual

MicroTech II Remote I/O Panel Installation Manual MicroTech II Remote I/O Panel Installation Manual Installation Manual IM 783-2 Group: Controls Part Number: IM 783 Date: November 2006 Supersedes: IM 783-1 Table of Contents Notice... 3 Reference Documents...

More information

ATSU01N209LT soft starter for asynchronous motor - ATSU01-9 A V KW

ATSU01N209LT soft starter for asynchronous motor - ATSU01-9 A V KW Characteristics soft starter for asynchronous motor - ATSU01-9 A - 200..480V - 1.5..4 KW Complementary Assembly style Function available Power supply voltage limits Main Range of product Product or component

More information

UNT1100 Series. Binary Output Jumpers AO2 AO1 AO3 AO4 AOCM AOCM AOCM AOCM AO1. AI Switches Job Information N2 Address. Ref N2+ N2- ADDR 0 = ALL OPEN

UNT1100 Series. Binary Output Jumpers AO2 AO1 AO3 AO4 AOCM AOCM AOCM AOCM AO1. AI Switches Job Information N2 Address. Ref N2+ N2- ADDR 0 = ALL OPEN 1 2 8 4 AI6 R R Installation Bulletin UNT1100 Issue Date 0309 UNT1100 Series Introduction The Unitary (UNT) controller (UNT1100 Series) is a digital controller with applications for air handling units,

More information

User s Manual. ACS550-PD 3R Irrigation Packaged Drive Supplement to ACS550-U1 User s Manual

User s Manual. ACS550-PD 3R Irrigation Packaged Drive Supplement to ACS550-U1 User s Manual User s Manual ACS550-PD 3R Irrigation Packaged Drive Supplement to ACS550-U1 User s Manual 2 ACS550-PD 3R Irrigation Packaged Drive ACS550 Drive Manuals GENERAL MANUALS ACS550-U1 User s Manual (1 200 HP)

More information

Installation, Operation, and Service Manual SIEMENS HEALTHCARE INTEGRATED ELECTRICAL CABINET

Installation, Operation, and Service Manual SIEMENS HEALTHCARE INTEGRATED ELECTRICAL CABINET Technical Publications SIEMENS HEALTHCARE INTEGRATED ELECTRICAL CABINET for ARTIS Q / Q.ZEN / ONE ARTIS ZEEGO / ZEEGO.ZEN ARTIS ZEE MULTIPURPOSE SINGLE PLANE IECAX480V125A Main Disconnect Panel Bevco Engineering

More information

TSP-BCM48, TSP-BCM48A. Operating Instruction Manual. Page 1 of 13

TSP-BCM48, TSP-BCM48A. Operating Instruction Manual.  Page 1 of 13 Battery Controller Module TSP-BCM24, TSP-BCM24A TSP-BCM48, TSP-BCM48A Operating Instruction Manual http://www.tracopower.com Page 1 of 13 Dimensions drawings: TSP-BCM24 & TSP-BCM48 Weight: 0.816lb Gewicht:

More information

ZBRN1 access point- 2 RJ V AC/DC-4 displays-5 LEDs-Eth-Modbus-wireless radio

ZBRN1 access point- 2 RJ V AC/DC-4 displays-5 LEDs-Eth-Modbus-wireless radio Characteristics access point- 2 RJ45-24..240V AC/DC-4 displays-5 LEDs-Eth-Modbus-wireless radio Main Range of product Product or component type Device short name Product specific application Function of

More information

ASCO 920 Remote Control (RC) Switches

ASCO 920 Remote Control (RC) Switches Maximum reliability and excellent value ASCO 920 Remote Control (RC) Switches ASCO 920 Remote Control Switch in Type Enclosure The ASCO 920 is designed as a feeder disconnect switch for load capacities

More information

Semi-hermetic Air-cooled Condensing Units

Semi-hermetic Air-cooled Condensing Units Semi-hermetic Air-cooled Condensing Units For Indoor and Outdoor Applications DFA-002-1 R22 R404A R507 R22 DFA Indoor Model Standard Features Bitzer OCTAGON series compressors up to 7 ½ HP. Dual adjustable

More information

Power Base AI. Power Base AI. Technical Sheets

Power Base AI. Power Base AI. Technical Sheets Power Base AI Power Base AI Technical Sheets odular Electrical System System Overview Haworth s Power Base AI modular electrical system provides a flexible, reconfigurable power distribution infrastructure

More information

Quick Start. This document describes how to install the Juniper Networks PTX5000 Packet Transport

Quick Start. This document describes how to install the Juniper Networks PTX5000 Packet Transport PTX5000 Packet Transport Router Quick Start September 2017 Part Number: 530-066788 Revision 01 This document describes how to install the Juniper Networks PTX5000 Packet Transport Router. Contents Quick

More information

RadioRA 2 Visor Controls

RadioRA 2 Visor Controls RadioRA 2 Visor Controls allow lights, shades / draperies, and other equipment to be controlled from the car with just a touch of a button on the Visor Control Transmitter or HomeLink compatible visor

More information

ATS22D88S6U. ATS22D88S6U soft starter-ats22-control110v-power 208V(25hp)/230V(30hp)/460V(60hp)/575V(75hp) Product data sheet Characteristics.

ATS22D88S6U. ATS22D88S6U soft starter-ats22-control110v-power 208V(25hp)/230V(30hp)/460V(60hp)/575V(75hp) Product data sheet Characteristics. Characteristics soft starter-ats22-control110v-power 208V(25hp)/230V(30hp)/460V(60hp)/575V(75hp) Main Range of product Altistart 22 Product or component type Product destination Product specific application

More information

Setting method Indication Control Output Model method mode Thermocouple (with sensor burnout detection circuit)

Setting method Indication Control Output Model method mode Thermocouple (with sensor burnout detection circuit) Temperature Controller DIN-sized (48 x 48 mm) Temperature Controller With Digital Setting Compact, low-cost Temperature Controller Incorporates proportional adjustment and reset adjustment function. Incorporates

More information

PROLINE ExtERNal ComPONENts. PROLINE tops and Bases

PROLINE ExtERNal ComPONENts. PROLINE tops and Bases Spec-00428 E763.422.2211 763.422.2600 PROLINE ExtERNal ComPONENts PROLINE Tops and Bases PROLINE ExtERNal ComPONENts PROLINE tops and Bases Solid tops Solid Tops are used to close the top opening on an

More information

Installation Notes TII Model 341 Protector

Installation Notes TII Model 341 Protector Installation Notes TII Model 341 Protector (ATT-IS PEC 32918) for MERLIN Communications System In Range Out of Building (IROB) Station Installation By Trained Technician Only WARNING: Failure to follow

More information

ATS22C21S6U softstarter-ats22-control110vpower208v(60hp)/230v(75hp)/460v(150hp)/575v(200hp)

ATS22C21S6U softstarter-ats22-control110vpower208v(60hp)/230v(75hp)/460v(150hp)/575v(200hp) Characteristics softstarter-ats22-control110vpower208v(60hp)/230v(75hp)/460v(150hp)/575v(200hp) Main Range of product Altistart 22 Product or component type Product destination Product specific application

More information

Installing the Tracer MP503 Input/Output Module Ordering number: ,

Installing the Tracer MP503 Input/Output Module Ordering number: , Installing the Tracer MP503 Input/Output Module Ordering number: 4950 0490, 4950 0590 Product overview The Tracer MP503 input/output (I/O) module is a field-installed device used to monitor inputs and

More information

Hi-lume 1% EcoSystem Constant-Voltage 24 V- LED Driver with Soft-on, Fade-to-Black Dimming Technology

Hi-lume 1% EcoSystem Constant-Voltage 24 V- LED Driver with Soft-on, Fade-to-Black Dimming Technology 50016452a Dimming Driver Hi-lume 1% EcoSystem Constant-Voltage 24 V- Driver with Soft-on, Fade-to-Black Dimming Technology The CE-rated Hi-lume 1% Constant-Voltage Driver (LDE1) is a high-performance driver

More information

920 Remote Control (RC) Switches

920 Remote Control (RC) Switches 920 Remote Control (RC) Switches ASCO is the global leader in power switching and controls ASCO 920 PRODUCT SPECIFICATIONS SWITCH ONLY (PANELBOARD MOUNTING) 1,2,3 () DIMENSIONS, IN.(MM) WIDTH HEIGHT DEPTH

More information

rcc.1081 Installation Instructions

rcc.1081 Installation Instructions rcc.1081 Installation Instructions Table of Contents Introduction...1 Specifications...2 Mounting...3 Wiring...5 Wiring Method...7 BACnet Network Wiring...8 Setting BACnet Address...9 Setting the BACnet

More information

PGR-4300 MANUAL GENERATOR GROUND-FAULT RELAY

PGR-4300 MANUAL GENERATOR GROUND-FAULT RELAY Tel: +1-800-832-3873 E-mail: techline@littelfuse.com www.littelfuse.com PGR-4300 MANUAL GENERATOR GROUND-FAULT RELAY REVISION 3-B-041318 Copyright 2018 by Littelfuse, Inc. All rights reserved. Document

More information

PHOENIX CONTACT Features

PHOENIX CONTACT Features Electronic monitoring relay for temperature monitoring Data sheet 107385_en_00 1 Description PHOENIX CONTACT - 2016-05-10 Features Safety and system availability requirements are constantly on the increase

More information

6 Port Unmanaged Industrial Gigabit Ethernet Switch w/ 4 PoE+ Ports and Voltage Regulation - DIN Rail / Wall-Mountable

6 Port Unmanaged Industrial Gigabit Ethernet Switch w/ 4 PoE+ Ports and Voltage Regulation - DIN Rail / Wall-Mountable 6 Port Unmanaged Industrial Gigabit Ethernet Switch w/ 4 PoE+ Ports and Voltage Regulation - DIN Rail / Wall-Mountable Product ID: IES61002POE The IES61002POE 6-Port Industrial PoE+ switch lets you connect

More information

Model Number Structure

Model Number Structure Analogue Temperature Controller E5C2 DIN-sized (48 x 48 mm) Temperature Controller with Analog Setting Compact, low-cost Temperature Controller. Incorporates proportional control and reset adjustment function.

More information

RM17TG. Main. Product or component type. Product specific application. Relay monitored parameters. Switching capacity in VA

RM17TG. Main. Product or component type. Product specific application. Relay monitored parameters. Switching capacity in VA Characteristics phase control relay RM17-T - range 183..484 V AC Main Range of product Product or component type Relay type Product specific application Relay name Relay monitored parameters Switching

More information

Hardware Installation. Tracer MP581 Programmable Controller CNT-SVN01C-EN

Hardware Installation. Tracer MP581 Programmable Controller CNT-SVN01C-EN Hardware Installation Tracer MP581 Programmable Controller CNT-SVN01C-EN Hardware Installation Tracer MP581 Programmable Controller CNT-SVN01C-EN November 2005 Tracer MP581 Programmable Controller Hardware

More information

Hi-lume Premier 0.1% EcoSystem LED Driver

Hi-lume Premier 0.1% EcoSystem LED Driver Hi-lume Premier 0.1% EcoSystem LED Driver s provide a high performance solution for any space, in any application. They provide smooth, continuous dimming down to 0.1% of full output current, and fade

More information

System Storage EXP3000 Rack Installation Instructions

System Storage EXP3000 Rack Installation Instructions System Storage EXP3000 Rack Installation Instructions Review the documentation that comes with your rack cabinet for safety and cabling information. When you install the IBM System Storage EXP3000 in a

More information

Haworth Power Technical Sheets January 2018

Haworth Power Technical Sheets January 2018 Haworth Power Technical Sheets January 2018 Includes Accessories This page intentionally left blank. Table of Contents Desk Top Port Power Tap Cord Power Tap Conduit Enchanced Power Module Flip Top Unit

More information

Operating Instructions

Operating Instructions Introduction To protect the signal lines of field devices and systems in the cabinet against lightning. Pepperl+Fuchs covers the complete range of Surge Protection Barriers. Housing types Depending on

More information

LCP128 Dimming & Switching System

LCP128 Dimming & Switching System Dimming & Switching System lcp230240-1 05.09.05 System Overview is a combination dimming and switching system that provides a complete lighting control solution. The system consists of panels and control

More information

PHS Series. PowerHUBB Node - Satellite

PHS Series. PowerHUBB Node - Satellite PHS Series PowerHUBB Node - Satellite Project Name NETWORK Catalog No. Date The Hubbell Control Solutions' (HCS) PowerHUBB node provides power distribution architecture and data connectivity to create

More information

RadioRA 2 Visor Controls

RadioRA 2 Visor Controls RadioRA 2 Visor Controls allow lights, shades / draperies, and other equipment to be controlled from the car with just a touch of a button on a Visor Control Transmitter or a HomeLink compatible visor

More information

DMC2. Installation Guide Version 1.0. Area for main photograph. Area for insert photo. W: 46.1mm up to 79 mm H: 46.1mm

DMC2. Installation Guide Version 1.0. Area for main photograph. Area for insert photo. W: 46.1mm up to 79 mm H: 46.1mm Area for main photograph Area for insert photo W: 46.1mm up to 79 mm H: 46.1mm X: 12.6mm absolute on page Y: 132.6mm abs on page This insert has a shadow DMC2 Installation Guide Version 1.0 Contents DMC2

More information

LXM32SD18M2 motion servo drive - Lexium 32-single phase supply voltage 115/230V - 0.5/1.kW

LXM32SD18M2 motion servo drive - Lexium 32-single phase supply voltage 115/230V - 0.5/1.kW Product data sheet Characteristics LXM32SD18M2 motion servo drive - Lexium 32-single phase supply voltage 115/230V - 0.5/1.kW Main Range of product Lexium 32 Product or component type Device short name

More information

ATS22D75S6 soft starter-ats22-control 220V-power 230V(18.5kW)/ V(37kW)/500V(45kW)

ATS22D75S6 soft starter-ats22-control 220V-power 230V(18.5kW)/ V(37kW)/500V(45kW) Characteristics soft starter-ats22-control 220V-power 230V(18.5kW)/400...440V(37kW)/500V(45kW) Price* : 683.00 GBP Main Range of product Altistart 22 Product or component type Product destination Product

More information

Yes Additional interface boards may be required.

Yes Additional interface boards may be required. Revision E February 2017 Solutions for Upgrading from HomeWorks Illumination to HomeWorks QS The following guide has been developed to assist those interested in upgrading an existing HomeWorks Illumination

More information

Engine Control Unit, ECU 100 Engine control Engine monitoring and protection Easy-to-read graphical display Integrated emulation software solution

Engine Control Unit, ECU 100 Engine control Engine monitoring and protection Easy-to-read graphical display Integrated emulation software solution DATA SHEET Engine Control Unit, ECU 100 Engine control Engine monitoring and protection Easy-to-read graphical display Integrated emulation software solution DEIF A/S Frisenborgvej 33 DK-7800 Skive Tel.:

More information

Energi Savr NodeTM Programming Interface

Energi Savr NodeTM Programming Interface NodeTM QSE-CI-AP-D NodeTM The QSE-CI-AP-D is a programming interface designed to be used with NodeTM units. It is compatible with the entire NodeTM product family (models starting with QSN- and QSNE-),

More information

2.) Cabinet setup and preset data shall, as standard, be fully user programmable on a per cabinet or system wide basis.

2.) Cabinet setup and preset data shall, as standard, be fully user programmable on a per cabinet or system wide basis. A21 DIMMER CABINET SPECIFICATION. GENERAL. A.) Overview. 1.) The dimmer cabinets shall be fully digital, designed specifically for architectural and entertainment lighting applications, and shall consist

More information

RM22TG. Product data sheet Characteristics. three-phase control relay Vac, 2 C/O. Main. Complementary. Network number of phases

RM22TG. Product data sheet Characteristics. three-phase control relay Vac, 2 C/O. Main. Complementary. Network number of phases Characteristics three-phase control relay 183 528Vac, 2 C/O Main Range of product Product or component type Relay type Network number of phases Relay name Relay monitored parameters Time delay type Switching

More information

VL BPC 100. Valueline configurable box PC. Data sheet 3063_en_E. 1 Description. 2 Features

VL BPC 100. Valueline configurable box PC. Data sheet 3063_en_E. 1 Description. 2 Features Valueline configurable box PC Data sheet 0_en_E Description PHOENIX CONTACT 0-07- Features The VL BPC 000 is a configurable box PC that can be mounted either directly on a wall or on a DIN rail. The VL

More information

ABL8BBU24400 battery control module V DC - 24 V - 40 A - for regulated SMPS

ABL8BBU24400 battery control module V DC - 24 V - 40 A - for regulated SMPS Characteristics battery control module - 24..28.8 V DC - 24 V - 40 A - for regulated SMPS Main Range of product Product or component type Input voltage Output voltage Maximum output current Complementary

More information

Temperature. Power requirements. Weight. Dimensions

Temperature. Power requirements. Weight. Dimensions Installing the Tracer Summit BMTX Building Control Unit Ordering numbers: BMTX001AAB000, BMTX001AAB010, BMTX001AAB001, BMTX001AAB011, BMTX001BAB000, BMTX001BAB010, BMTX001BAB001, BMTX001BAB011, BMTX001DAB000

More information

Rugged MediaConverter

Rugged MediaConverter Rugged MediaConverter Installation Guide RuggedCom Inc. 30 Whitmore Road, Woodbridge, Ontario Canada L4L 7Z4 Web: http://www.ruggedcom.com/ Tel: (905) 856-5288 Fax: (905) 856-1995 Toll Free: (888) 264-0006

More information

ATS01N232RT soft starter for asynchronous motor - ATS01-32 A V

ATS01N232RT soft starter for asynchronous motor - ATS01-32 A V Characteristics soft starter for asynchronous motor - ATS01-32 A - 460..480 V Complementary Assembly style Function available Power supply voltage limits Main Range of product Altistart 01 Product or component

More information

Analog Voltage Combination Module

Analog Voltage Combination Module Analog Voltage Combination Module T1F-8AD4DA-2 8-channel analog voltage input 4-channel analog voltage output The combination 8-in and 4-out voltage module uses a T1K-8B or T1K-8B-1 base, which is purchased

More information

DeltaV Bulk Power Supplies

DeltaV Bulk Power Supplies DeltaV Distributed Control System Product Data Sheet DeltaV Bulk Power Supplies DeltaV 5 A, 10A, 20 A, 40 A Bulk Power Supplies. DeltaV 20 A, 40 A and 80 A Bulk Power Supply Redundancy Modules. Easy to

More information

HCS Newsletter No. 43, Dated Thursday, 04 December, 2003 HCS DataLine Cabinets and Enclosures

HCS Newsletter No. 43, Dated Thursday, 04 December, 2003 HCS DataLine Cabinets and Enclosures HCS - Made in Turkey With Pride! HCS Newsletter No. 43, Dated Thursday, 04 December, 2003 HCS DataLine Cabinets and Enclosures HCS, the only Turkish manufacturer of state-of-the-art LAN cabling systems

More information