CINT W Triple Output Industrial Series

Size: px
Start display at page:

Download "CINT W Triple Output Industrial Series"

Transcription

1 CINT3 W Triple Output Features 2 x 4 x.3 Package Suitable for U Applications W w/air, 8W convection cooled Universal Input 9-264Vac Efficiency 87% typical Approved to CSA/EN/IEC/UL695-, 2 nd Edition Power Fail Signal Remote Sense 3 Year Warranty RoHS Compliant Description The CINT3 Series are industrial grade, high efficiency, triple output power supplies in a small 2 x 4 size. The CINT3 family is ideal for Industrial and ITE applications requiring multiple outputs and small footprint. Compliant to IEC695-2 nd edition, the CINT3 models feature outputs of 5/±2V, 5/±5V, 5/±24V, includes a Power Fail/DC OK signal, and meet Class B Conducted EMI. Model Selection Model Output Current** Ripple & Total OVP Number Volts* w/2lfm air Convection Noise*** Regulation Threshold CINT3A58K CINT3A78K CINT3A98K V 5V 4.A.A.% pk-pk ±2% 7.5V max. V2 2V 6.A 4.5A.% pk-pk ±3% 5%-35% V3-2V.A.A 2.% pk-pk ±% 5%-35% V 5V 4.A.A.% pk-pk ±2% 7.5V max. V2 5V 4.5A 3.5A.% pk-pk ±3% 5%-35% V3-5V.A.A 2.% pk-pk ±% 5%-35% V 5V 2.A 8.A.% pk-pk ±2% 7.5V max. V2 24V 4.A 3.A.% pk-pk ±3% 5%-35% V3-24V.A.A 2.% pk-pk ±% 5%-35% Notes: * 5V output is adjustable with +/-% range ** Total convection power is 8 Watts. *** Measured with noise probe directly across output terminals, and load terminated with.µf ceramic and µf low ESR capacitors. Ripple & Noise of V2 at no load is 2% maximum. General Specifications AC Input -24Vac, ±%, 47-63Hz, 2 37Vdc Turn On Time Less than 2 (inversely proportional to input voltage and thermistor temperature) Input Current 5Vac:.5A, 23Vac:.75A Hold-up Time 6mS typical at W, 2Vac input CINT3 REV.2, 9-SEP-4

2 CINT3 W Triple Output General Specifications (continued) Inrush Current 264Vac, cold start: will not exceed 45A Signals AC Power Fail, DC OK Input Fuses F, F2: 2.5A, 25Vac fuses provided on all models Overload Protection 5%-3% above rating for V2 & V3, %- 2% for V. Hiccup Mode Earth Leakage Current <29µA@264Vac, 6Hz, NC Short Circuit Protection Provided - no damage will occur if the output is shorted. Efficiency 87% typical at 23Vac Overvoltage Protection See models chart for trip range. Output Power W continuous with 2 lfm airflow, 8W convection cooled See chart for specific voltage model ratings. Switching Frequency PFC: 75kHz typical Transient Response 5µS typ. for return to within.5% of nominal, 5% load step. i/ t <.2A/µS. Max Volt Deviation = 3% Isolation Input-Output: 4Vac Input-Ground: 8Vac Output-Ground: 5Vac Ripple and Noise See models chart Operating Temperature - C to +7 C Output Voltage See models chart Temperature Derating Derate output power linearly above 5 C to 5% at 7 C Voltage Adjustability +/-% from nominal on 5V output Storage Temperature -4 C to +85 C Minimum Load Not required Altitude Operating: -5 to, ft. Non-operating: -5 to 4, ft. Total Regulation See models chart Relative Humidity 5% to 95%, non-condensing Vibration Operating:.3g²/Hz,.5grms overall, 3 axes, min/axis Non-Operating:.26g²/Hz, 5.grms overall, 3 axes, hr/axis Shock Operating: Half-sine, 2gpk, ms, 3 axes, 6 shocks total Non-Operating: Half-sine, 4 gpk, ms, 3 axes, 6 shocks total Dimensions W: 2. x L: 4. x H:.3 Safety Standards EN/CSA/UL/IEC 695-, 2 nd Edition Weight 2g MTBF 245, hours, 25 C Ambient, Vac input Auxiliary Signals AC Power Fail: Remote Sense: During normal operation, stays HIGH. Signal goes LOW with at least 6mS warning before loss of DC output from AC failure. (5V output, optional) Will compensate for.5v drop min. Will operate without remote sense connected. Reverse connection protected. DC OK: Open collector logic signal goes and stays HIGH ms to 5mS after main output reaches regulation. Notes:. Specifications are for convection rating at factory settings at 5 Vac input, 25 C ambient unless otherwise stated. 2. For DC input an external DC safety rated fuse must be used. CINT3 REV.2, 9-SEP-4 2

3 CINT3 W Triple Output EMI/EMC Compliance Conducted Emissions Radiated Emissions Static Discharge Immunity Radiated RF Immunity EFT/Burst Immunity Line Surge Immunity Conducted RF Immunity Power Frequency Magnetic Field Immunity Voltage Dip Immunity Line Harmonic Emissions Flicker Test EN55/22 Class B, FCC Part 5, Subpart B, Class B EN55/22 Class A; FCC Part 5, Subpart A, Class A EN6-4-2, Criteria A, 6kV Contact Discharge, 8kV air discharge EN6-4-3, 3V/m. Criteria A EN6-4-4, 2kV/5kHz, Criteria A EN6-4-5, kv differential, 2kV common-mode, Criteria A EN6-4-6, 3Vrms, Criteria A EN6-4-8, 3A/m, Criteria A EN6-4-, % Vin,.5cycle; 4% Vin, 5 cycles; 7% Vin, 25 cycles; Criteria A EN6-3-2, Class A, B, C, & D EN6-3-3, Complies (dmax<6%) Mechanical Drawing Notes:. All dimensions in inches (mm), tolerance is ± Mounting holes should be grounded for EMI purpose 3. Mounting J is safety ground connection 4. This power supply requires mounting on metal standoffs.2 (5 m) in height. CINT3 REV.2, 9-SEP-4 3

4 CINT3 W Triple Output Connector Information Input Connector J PIN ) AC NEUTRAL PIN 2) EMPTY PIN 3) AC LINE Mating Connector: Molex Pins= AMP # Pins= Ground J.87 FASTON TAB Mating Connector: Molex -92 DC Output Connector J2 PIN ) +V PIN 4) GND PIN 7) V2 PIN 2) +V PIN 5) GND PIN 8) V3 PIN 3) GND PIN 6) GND Mating Connector: Amp # Pins=Amp # Signal Connector J3 PIN ) Power Fail/DC OK PIN 2) GND PIN 3) +Remote Sense PIN 4) Remote Sense Mating Connector: Amp # Pin= Amp #37589 Isolation Specifications Parameter Conditions/Description Min Nom Max Units Insulation Safety Rating Electric Strength Test Voltage Leakage Current Input/Ground Input/Output Output/Ground Input/Ground Input/Output Output/Ground Basic Reinforced Operational - - Parameter Conditions/Description Max Vac Vac Vac Earth Leakage Current Touch Current Normal Condition (NC) Single Fault Condition (SFC) Normal Condition (NC) Single Fault Condition (SFC) 29µA 42µA 9µA 7µA Input Specifications All specifications apply over specified input voltage, output load, and temperature range, unless otherwise noted. Parameter Conditions/Description Min Nom Max Units Input Voltage 9 5/ Vac Input Frequency 47 5/6 63 Hz Input Current 5Vac/max load.5 A Input Current 23Vac/max load.75 A Inrush Current 264Vac, cold start, 25 C A Efficiency Vi nom, Io nom CINT3A58K CINT3A78K CINT3A98K - 87% - % Output Specifications Parameter Conditions/Description Min Nom Max Units Output Current V Output Current V2 Output Current V3 Output Current V Output Current V2 Output Current V3 Output Current V Output Current V2 Output Current V3 CINT3A58K CINT3A78K CINT3A98K ADC ADC ADC CINT3 REV.2, 9-SEP-4 4

5 CINT3 W Triple Output Output Specifications (continued) Parameter Conditions/Description Min Nom Max Units Static Line Regulation V Vi min-vi max, Vi nom, -% Io max -2-2 % Vo nom Static Line Regulation V2 Vi min-vi max, Vi nom, -% Io2 max -3-3 % Vo nom Static Line Regulation V3 Vi min-vi max, Vi nom, -% Io3 max - - % Vo nom Static Load Regulation V (Droop Characteristic) Static Load Regulation V2 (Droop Characteristic) Static Load Regulation V3 (Droop Characteristic) Vi min-vi max, Vi nom, -% Io max -2-2 % Vo nom Vi min-vi max, Vi nom, -% Io2 max -3-3 % Vo nom Vi min-vi max, Vi nom, -% Io3 max - - % Vo nom Hold-Up Time Vin = 2Vac, Po = W ms Dynamic Load Regulation V, V2, V3 Load change =5%, di/dt =.2A/µS 3 % Vo nom Start-Up Time Vin = 5Vac, Io nom - 2 S Ripple & Noise V 2MHz bandwidth % % Vo nom Ripple & Noise V2 2MHz bandwidth % % Vo nom Ripple & Noise V3 2MHz bandwidth 2% % Vo nom Protection All specifications apply over specified input voltage, output load, and temperature range, unless otherwise noted. Parameter Conditions/Description Min Nom Max Units Input Fuse T2.5A/25V internal fuse in both line & neutral Not user accessible Input Transient Protection 2KV(CM) and KV(DM) surge 2 KV (CM) Short Circuit Protection Overload Protection Hiccup Mode Hiccup Mode Overvoltage Protection Latching Type, recycle AC input to reset See models chart for trip ranges Characteristic Curves (Note: All waveforms below are based on CINT3A58K model) Output vs. Temperature 8W convection cooled and W continuous with 2 LFM airflow. Derate output power to 5% at 7 C. Output Power (W) Temperature ( C) Convection 2LFM Cooling CINT3 REV.2, 9-SEP-4 5

6 CINT3 W Triple Output Ripple & Noise To verify that the output ripple and noise does not exceed the level specified in the product specification. Measured using a scope probe socket with.µf ceramic and a µf electrolytic capacitor connected in parallel across it, BW limit with 2MHz. Output Transient Response V 5% load step within the regulation limits of minimum and maximum load, di/dt<.2a/µsec. Recovery time not specified as there is no laps in regulation with a 5% Load Step. Maximum voltage deviation is 3%. Output Transient Response V2 5% load step within the regulation limits of minimum and maximum load, di/dt<.2a/µsec. Recovery time not specified as there is no laps in regulation with a 5% Load Step. Maximum voltage deviation is 3%. CINT3 REV.2, 9-SEP-4 6

7 CINT3 W Triple Output Output Transient Response V3 5% load step within the regulation limits of minimum and maximum load, di/dt<.2a/µsec. Recovery time not specified as there is no laps in regulation with a 5% Load Step. Maximum voltage deviation is 3%. Output Overload Characteristic V Supply shall protect itself against Overload conditions. The Power Supply shall recover from Overload Conditions without operator intervention. Output Overload Characteristic V2 CINT3 REV.2, 9-SEP-4 7

8 CINT3 W Triple Output Output Overload Characteristic V3 Output Short Circuit Characteristic V Supply shall protect itself against Short Circuit conditions. The Power Supply shall recover from short circuit conditions without operator intervention. Output Short Circuit Characteristic V2 CINT3 REV.2, 9-SEP-4 8

9 CINT3 W Triple Output Output Short Circuit Characteristic V3 Output Overvoltage Characteristic V Supply shall protect itself against over voltage conditions. The Power Supply shall latch and require AC input recycle to reset. AC input 9V 6Hz AC input 264V 5Hz Output Overvoltage Characteristic V2 CINT3 REV.2, 9-SEP-4 9

10 CINT3 W Triple Output Output Overvoltage Characteristic V3 Startup Time Hold-up Time Start up time is <2seconds Hold up time is 6mS minimum Power Fail Signal Timing Active Low TTL logic signal goes high - 5 ms after main output; it goes low at least 6 ms before loss of regulation. Data Sheet 22 SL Power Electronics Corp. The information and specifications contained herein are believed to be correct at the time of publication. However, SL Power accepts no responsibility for consequences arising from reproduction errors or inaccuracies. Specifications are subject to change without notice. CINT3 REV.2, 9-SEP-4

CINT W Single Output Industrial Series

CINT W Single Output Industrial Series Features 2 x 4 x 1.3 Package For 1U Applications 175W w/air, 12W convection cooled Universal Input 9264 VAC Average Efficiency meets Level V Requirements Approved to CSA/EN/IEC/UL695, 2nd Edition 12V fan

More information

ME to 30W Single Output External Power Medical Series. Features

ME to 30W Single Output External Power Medical Series. Features Features Meets UL/EN/IEC60601-1-2, 4th edition for EMC * Approved to EN/IEC/UL60601-1, 3rd edition 2 MOPP input-output isolation Meets DoE Efficiency Level VI Requirements No load input power Average Efficiency

More information

LPS. ME20 20W Single Output External Power Medical Series. Features

LPS. ME20 20W Single Output External Power Medical Series. Features Features ME20 Meets UL/EN/IEC60601-1-2, 4th ed. for EMC * LPS Approved to EN/IEC/UL60601-1, 3rd edition with isolation levels which satisfy the 2 MOPP requirements. Meets DoE Efficiency Level VI Requirements

More information

300 WATT, PFC, OPEN FRAME POWER SUPPLIES TABLE 1. OUTPUT RATINGS AND SPECIFICATIONS, RMW 300W SERIES

300 WATT, PFC, OPEN FRAME POWER SUPPLIES TABLE 1. OUTPUT RATINGS AND SPECIFICATIONS, RMW 300W SERIES INSTRUCTION MANUAL KEPCO An ISO 9001 Company. 300 WATT, PFC, OPEN FRAME POWER SUPPLIES RMW 300W SERIES I INTRODUCTION SCOPE OF MANUAL. This instruction manual covers the installation and operation of the

More information

Electrical Specifications VAC/390 VDC, Universal (Derate from 100% at 100V AC to 77% at 80V AC)

Electrical Specifications VAC/390 VDC, Universal (Derate from 100% at 100V AC to 77% at 80V AC) 180 Watt Industrial Features 4 x 2 x 0.75 Inches Form factor 180 Watts with Forced Air Cooling Efficiencies upto 92% -40 to 70 degree operating temperature* 12V / 0.5A Fan Output, Thermal Shut-Down feature

More information

MVAD040 Series 40W 2" x 4" AC-DC Power Supply Converter

MVAD040 Series 40W 2 x 4 AC-DC Power Supply Converter www.murata-ps.com MVAD040 Series DESCRIPTION The MVAD040 series switching power supplies utilize advanced component and circuit technologies to deliver high effi ciency. Designed for Medical, Telecom,

More information

Safety Standards. Model Number: Unit Weight:

Safety Standards. Model Number: Unit Weight: MEA-250A24C Highlights & Features Meet Efficiency Level VI Safety Approvals to IEC 60601-1 3.1 Ed. & IEC 60950-1 Compliant with IEC 60601-1-2 3 th and 4 th Ed. Requirements IP22 ingress protection rating

More information

Watts. xppower.com. General. Input. Output. Environmental. EMC & Safety. Compact Size. IT & Medical Approvals.

Watts. xppower.com. General. Input. Output. Environmental. EMC & Safety. Compact Size. IT & Medical Approvals. 4- Watts ECM Series Compact Size xppower.com IT & Medical Approvals Convection-cooled Class I and II Construction DC Input Version Available (DCM Series) PoE Isolation Version Available (POE Series) 3

More information

Watts. xppower.com. General. Input. Environmental. EMC & Safety. Output. IT & Medical Approvals. Energy Efficiency Level V, CEC2008 & EISA 2007

Watts. xppower.com. General. Input. Environmental. EMC & Safety. Output. IT & Medical Approvals. Energy Efficiency Level V, CEC2008 & EISA 2007 AC-DC 85-50 Watts AHM Series IT & Medical Approvals xppower.com Energy Efficiency Level V, CEC008 & EISA 007

More information

400AUS24 B MDS AUS. MDS Medical AC-DC Open Frame 24Volt, 400Watt / MDS-400AUS24 B. General Description. Model Information. Model Numbering ```

400AUS24 B MDS AUS. MDS Medical AC-DC Open Frame 24Volt, 400Watt / MDS-400AUS24 B. General Description. Model Information. Model Numbering ``` 400AUS24 B Highlights & Features Safety Approvals to IEC 60601-1 3.1rd ed. & IEC 60950-1 Compliant with IEC 60601-1-2 4th Ed. Requirements Low touch current (

More information

ORDERING INFORMATION SEE PAGE 6

ORDERING INFORMATION SEE PAGE 6 400W High Density Medical/Industrial Grade Open Frame Power Supplies Medical Safety Approval 60601-1 3rd Edition 2 MOPP Class 2 for home use medical applications (BSM400) Single output with 5V Auxiliary

More information

60 Watt Medical (MWLT)

60 Watt Medical (MWLT) 60 Watt Medical (MWLT) Features 4 x 2 x 1.2 inches Ultra high efficiency > 85% 50-65 W from 1 to 3 outputs Low leakage current < 250 µa Nemko, UL & CSA approvals to IEC60601 EN55022-B, CISPR22-B, FCC Part15

More information

40 & 60 Watt Models. Low Leakage Current. EN61000 Compliant. Single & Multiple Outputs. Cover Kits Available

40 & 60 Watt Models. Low Leakage Current. EN61000 Compliant. Single & Multiple Outputs. Cover Kits Available ECM40-60 40 & 60 Watt Models Small Size 2.0 x 4.0 x 1.2 Low Leakage Current Industrial & Medical Approvals Full Load Available Convection Cooled Wide Operating Temperature 0 C to +70 C Level B Conducted

More information

Electrical Specifications VAC/390 VDC, Universal (Derate from 100% at 100V AC to 77% at 80V AC)

Electrical Specifications VAC/390 VDC, Universal (Derate from 100% at 100V AC to 77% at 80V AC) 180 Watt Medical Features 4 x 2 x 0.75 Inches Form factor 180 Watts with Forced Air Cooling Approval to EN60601 3rd Edition Efficiencies upto 92% -40 to 70 degree operating temperature* Dual fusing 12V

More information

Safety Standards. Model Number:

Safety Standards. Model Number: 060BAS12 A Highlights & Features Meet Efficiency Level VI Safety Approvals to IEC 60601-1 3rd ed. & IEC 60950-1 Compliant with IEC 60601-1-2 4th Ed. Requirements Low touch current (

More information

Universal Power Supplies

Universal Power Supplies , Features Universal input: 90 264 VAC or 120 30 VDC Active power factor correction (>0.95) High efficiency up to 93% Load share function for up to 3 units in parallel Adjustable output voltage EMI/EMC

More information

LFWLP350 SERIES 350 Watt Open Frame Power Supply Measures: 5.00 x 3.00 x 1.00

LFWLP350 SERIES 350 Watt Open Frame Power Supply Measures: 5.00 x 3.00 x 1.00 Features 5 x 3 x 1 Inches Form factor 350 Watts with Forced Air Cooling & 200 Watts Convection Cooling Efficiencies upto 94% -40 to 70 degree operating temperature* 12V / 0.5A Fan Output, Thermal Shut-Down

More information

LFWLP225 SERIES 225 Watt Open Frame Power Supply Measures: 4.00 x 2.00 x 1.00

LFWLP225 SERIES 225 Watt Open Frame Power Supply Measures: 4.00 x 2.00 x 1.00 Features 4 x 2 x 1 Inches Form factor 225 Watts with Forced Air Cooling Efficiencies upto 94% -40 to 70 degree operating temperature* 12V / 0.5A Fan Output, Thermal Shut-Down feature 3.37m Hours, Telcordia

More information

Safety Standards. Model Number:

Safety Standards. Model Number: 060AAS19 B Highlights & Features Meet Efficiency Level VI Safety Approvals to IEC 60601-1 3.1rd ed. & IEC 60950-1 Compliant with IEC 60601-1-2 4th Ed. Requirements Low touch current (

More information

Safety Standards. Model Number:

Safety Standards. Model Number: 040APS15 B Highlights & Features Safety Approvals to IEC 60601-1 3.1rd ed. & IEC 60950-1 Compliant with IEC 60601-1-2 4th Ed. Requirements Low touch current (

More information

Safety Standards. Model Number:

Safety Standards. Model Number: 090AAS15 F/B Highlights & Features Meet Efficiency Level VI Safety Approvals to IEC 60601-1 3.1rd ed. & IEC 60950-1 Compliant with IEC 60601-1-2 4th Ed. Requirements Low touch current (

More information

Safety Standards. Model Number:

Safety Standards. Model Number: 100APS24 B Highlights & Features Safety Approvals to IEC 60601-1 3.1rd ed. & IEC 60950-1 Compliant with IEC 60601-1-2 4th Ed. Requirements Low touch current (

More information

Electrical Specifications VAC/390 VDC, Universal (Derate from 100% at 100V AC to 95% at 85V AC)

Electrical Specifications VAC/390 VDC, Universal (Derate from 100% at 100V AC to 95% at 85V AC) 225 Watt Industrial Features 4 x 2 x 1 Inches Form factor 225 Watts with Forced Air Cooling Efficiencies upto 94% -40 to 70 degree operating temperature* 12V / 0.5A Fan Output, Thermal Shut-Down feature

More information

Safety Standards. Model Number:

Safety Standards. Model Number: 080AAS12 A Highlights & Features Safety Approvals to IEC 60601-1 3.1rd ed. & IEC 60950-1 Compliant with IEC 60601-1-2 4th Ed. Requirements Low touch current (

More information

Electrical Specifications. Input Current 115 VAC: 1 A max. 230 VAC: 0.5 A max.

Electrical Specifications. Input Current 115 VAC: 1 A max. 230 VAC: 0.5 A max. MLP75 Medical Features 3 x 2 x 1 Inches Form factor 75 Watts Convection Approval to EN60601 3 rd Edition Efficiencies upto 93% -40 to 70 degree operating temperature Dual fusing Thermal Shut-Down feature

More information

Safety Standards. Model Number:

Safety Standards. Model Number: 150AAS12 F/B Highlights & Features Meet DOE Level VI and ErP Lot 7 Safety Approvals to IEC 60601-1 3.1rd ed. & IEC 60950-1 Compliant with IEC 60601-1-2 4th Ed. Requirements Low touch current (

More information

Safety Standards. Model Number:

Safety Standards. Model Number: 060AAS15 B Highlights & Features Meet Efficiency Level VI Safety Approvals to IEC 60601-1 3.1rd ed. & IEC 60950-1 Compliant with IEC 60601-1-2 4th Ed. Requirements Low touch current (

More information

400AUS24 B MDS AUS. MDS Medical AC-DC Open Frame 24Volt, 400Watt / MDS-400AUS24 B. General Description. Model Information. Model Numbering ```

400AUS24 B MDS AUS. MDS Medical AC-DC Open Frame 24Volt, 400Watt / MDS-400AUS24 B. General Description. Model Information. Model Numbering ``` 400AUS24 B Highlights & Features Safety Approvals to IEC 60601-1 3rd ed. & IEC 60950-1 Risk management report available Low touch current (

More information

Application Package Dimension Output Input Output Output Protection Option Code Code Power Voltage Quantity Voltage Type (W) (VAC) (VDC)

Application Package Dimension Output Input Output Output Protection Option Code Code Power Voltage Quantity Voltage Type (W) (VAC) (VDC) Automation Datacom IPC Industry Measurement Telecom Automobile Boat Charger Medical PV Railway PART NUMBER STRUCTURE T A H 450 U S 12 - F2 Application Package Dimension Output Input Output Output Protection

More information

AC-DC POWER SUPPLIES UNIVERSAL INPUT, 65 WATT MEDICAL APPLICATIONS MUI65 SERIES

AC-DC POWER SUPPLIES UNIVERSAL INPUT, 65 WATT MEDICAL APPLICATIONS MUI65 SERIES AC-DC POWER SUPPLIES UNIVERSAL INPUT, 65 WATT MEDICAL APPLICATIONS 2MOPP Medical FEATURES Universal Input Range Operating Temperature Range: -25º to 80ºC (with derating) Compact Package: 2.00 3.00 1.16

More information

Electrical Specifications VAC/390 VDC, Universal (Derate from 100% at 100V AC to 90% at 90V AC)

Electrical Specifications VAC/390 VDC, Universal (Derate from 100% at 100V AC to 90% at 90V AC) WLP350 Industrial Features 5 x 3 x 1 Inches Form factor 350 Watts with Forced Air Cooling & 200 Watts Convection Cooling Efficiencies upto 94% -40 to 70 degree operating temperature* 12V / 0.5A Fan Output,

More information

12-15VDC (12V±5%) 24-28VDC (24V±5%)

12-15VDC (12V±5%) 24-28VDC (24V±5%) Features Description Universal AC input (85-264VAC) Long 7 year warranty Protections: SCP, OVP, OCP, OTP 1% full load burn-in test DC OK indicator LED with relay contacts cooling by free air convection,

More information

PART NUMBER STRUCTURE. P-DUKE Technology Co., Ltd Page 1

PART NUMBER STRUCTURE. P-DUKE Technology Co., Ltd Page 1 Automation Datacom IPC Industry Measurement Telecom Automobile Boat Charger Medical PV Railway PART NUMBER STRUCTURE T A H 450 U S 12 - F2 Application Package Dimension Output Input Output Output Protection

More information

040APS12 B MDS. MDS Medical AC-DC Open Frame 12Volt, 40Watt / MDS-040APS12 B ``` Highlights & Features. Safety Standards.

040APS12 B MDS. MDS Medical AC-DC Open Frame 12Volt, 40Watt / MDS-040APS12 B ``` Highlights & Features. Safety Standards. 040APS12 B Highlights & Features Safety Approvals to IEC 60601-1 3rd ed. & IEC 60950-1 Risk management report available Low touch current (

More information

100BPS15 B. MDS Medical AC-DC Open Frame 15Volt, 100Watt / MDS-100BPS15 B ``` Highlights & Features. Safety Standards.

100BPS15 B. MDS Medical AC-DC Open Frame 15Volt, 100Watt / MDS-100BPS15 B ``` Highlights & Features. Safety Standards. TECHNICAL DATASHEET 100BPS15 B Highlights & Features rd rd Safety Approvals to IEC60601-1 3 & 3.1 and IEC60950-1 Compact size 2 x4 Class B EMI and 4th Edition Immunity Compliant Low touch current (

More information

LFMWLP225 SERIES 225 Watt Open Frame Power Supply Measures: 4.00 x 2.00 x 1.00

LFMWLP225 SERIES 225 Watt Open Frame Power Supply Measures: 4.00 x 2.00 x 1.00 Features 4 x 2 x 1 Inches Form factor 225 Watts with Forced Air Cooling Approval to EN60601 3 rd Edition Efficiencies upto 94% -40 to 70 degree operating temperature* Dual fusing 12V / 0.5A Fan Output,

More information

Safety Standards. Model Number:

Safety Standards. Model Number: 065APS12 B Highlights & Features Safety Approvals to IEC 60601-1 3.1rd ed. & IEC 60950-1 Compliant with IEC 60601-1-2 4th Ed. Requirements Low touch current (

More information

5 x 8.5 x 1.61 Inch Form Factor. Convection Cooling Rated. Approved to EN Dual Fusing. Current Sharing. Open Frame. Peak Power Capability

5 x 8.5 x 1.61 Inch Form Factor. Convection Cooling Rated. Approved to EN Dual Fusing. Current Sharing. Open Frame. Peak Power Capability The MCC600 Series of open-frame medical power supplies, with its wide universal 85-264 VAC input range, is available at 600 W of output power and a variety of single output voltages. The MCC series is

More information

12-15VDC (12V±5%) 24-28VDC (24V±5%)

12-15VDC (12V±5%) 24-28VDC (24V±5%) Features DIN Rail Description Universal AC input (85-264VAC) Long 7 year warranty Protections: SCP, OVP, OCP, OTP 1% full load burn-in test DC OK indicator LED with relay contacts cooling by free air convection,

More information

efo Series Wide range AC/DC Single Output 1000W Rugged Power Supply Electrical Specification for: Telkoor Part Number:

efo Series Wide range AC/DC Single Output 1000W Rugged Power Supply Electrical Specification for: Telkoor Part Number: Electrical Specification for: efo1000-124 Series Wide range AC/DC Single Output 1000W Rugged Power Supply Telkoor Part Number: 900-1124-1000 GENERAL SCALE RELEASE DATE 05/08/2012 SHEET 1 OF 6 Rev Level

More information

PART NUMBER STRUCTURE. P-DUKE Technology Co., Ltd Page 1

PART NUMBER STRUCTURE. P-DUKE Technology Co., Ltd Page 1 Medical Automation Datacom IPC Industry Measurement Telecom Automobile Boat Charger PV Railway PART NUMBER STRUCTURE M A H 450 U S 12 - F2 Application Package Dimension Output Input Output Output Protection

More information

060AAS19 B MDS. MDS Medical AC-DC Adapter 19Volt, 60Watt / MDS-060AAS19 B. Highlights & Features. Safety Standards. Model Number: General Description

060AAS19 B MDS. MDS Medical AC-DC Adapter 19Volt, 60Watt / MDS-060AAS19 B. Highlights & Features. Safety Standards. Model Number: General Description 060AAS19 B Highlights & Features Safety Approvals to IEC 60601-1 3rd ed. & IEC 60950-1 Risk management report available Low touch current (

More information

MPO-120S Series. Single Output, 180W Compact, Open Frame AC/DC Power Supplies. Key Features:

MPO-120S Series. Single Output, 180W Compact, Open Frame AC/DC Power Supplies.   Key Features: MPO-120S Series Single, 180W Compact, Open Frame AC/DC Power Supplies Key Features: 180W Power Universal 90-264 AC Power Factor Correction EN 60950 Approved High Efficiency Five Single Models Meets EN

More information

Constant Voltage Mode

Constant Voltage Mode FEATURES: AC Input 1~277VAC Built-in Active PFC Function Protection: SCP / OVP / OTP Flicker Free High Operating Ambient Temp.: -3 ~+6 Surge protection: L-N 4KV, L-FG/N-FG 8KV Safety: UL 875 / PSE EMI:

More information

These power supplies are ideal for telecom, datacom, industrial equipment and other applications.

These power supplies are ideal for telecom, datacom, industrial equipment and other applications. The ABC60 Series of AC-DC open-frame power supplies, with its wide universal 90-264 VAC input range and high power density, is available at 60 W of output power and a variety of single and multiple output

More information

Electrical Specification for: efo Wide range AC/DC Single 12V Output 400W Power Supply Telkoor Part Number: CUSTOMER SIZE CAGE CO

Electrical Specification for: efo Wide range AC/DC Single 12V Output 400W Power Supply Telkoor Part Number: CUSTOMER SIZE CAGE CO Electrical Specification for: efo400-112 Wide range AC/DC Single 12V Output 400W Power Supply Telkoor Part Number: 900-4136-0000 GENERAL SCALE RELEASE DATE PRELIMINARY SHEET 1 OF 5 REVISION HISTORY Rev

More information

4 x 2 x 0.75 Inches Form factor. 180 Watts with Forced Air Cooling. Approved to EN/IEC Efficiencies up to 92% Standby Power < 0.

4 x 2 x 0.75 Inches Form factor. 180 Watts with Forced Air Cooling. Approved to EN/IEC Efficiencies up to 92% Standby Power < 0. The MBC180 Series of ultra low open frame medical power supplies feature a wide universal AC input range of 85 V 264 VAC, offering output power 180 W with 13 CFM of forced air cooling or up to 120 W with

More information

Enclosed Power Supplies

Enclosed Power Supplies , 15 150 Watt Features Very compact metal cased power supplies High operating temperature up to 70 C Low no load power consumption

More information

TECHNICAL DATASHEET MDS Medical AC-DC Open Frame 065APS24 B Highlights & Features Safety Standards Model Number: Unit Weight Dimensions (W x L x H):

TECHNICAL DATASHEET MDS Medical AC-DC Open Frame 065APS24 B Highlights & Features Safety Standards Model Number: Unit Weight Dimensions (W x L x H): 065APS24 B Highlights & Features Safety Approvals to IEC 60601-1 3rd ed. & IEC 60950-1 Risk management report available Low touch current (

More information

275 Watt Medical Ultra low profile

275 Watt Medical Ultra low profile 127 x 76 x 19 mm Form factor 275 Watts with Forced Air Cooling Approval to EN60601 3rd Edition Efficiencies upto 92% -40 to 70 degree operating temperature* Dual fusing Electrical Specifications 12V /

More information

Safety Standards. Model Number:

Safety Standards. Model Number: 040APS Highlights & Features Compliant to IEC 60601-1 3rd edition IT and medical safety approvals Low earth leakage Current (

More information

PART NUMBER STRUCTURE. P-DUKE Technology Co., Ltd Page 1

PART NUMBER STRUCTURE. P-DUKE Technology Co., Ltd Page 1 Medical Automation Datacom IPC Industry Measurement Telecom Automobile Boat Charger PV Railway PART NUMBER STRUCTURE M A F 150 U S 12 B - Application Package Dimension Output Input Output Output Protection

More information

CPCI - 6U - AC - 600W

CPCI - 6U - AC - 600W Electrical Specification for: CPCI - 6U - AC - 600W Telkoor Part Number: 900-6115-0000 SCALE RELEASE DATE 13/12/08 SHEET 1 OF 7 REVISION HISTORY Rev Level Rev Date Change Made Reason for Change Effective

More information

CLP0224 SERIES 200 Watt Open Frame Power Supply Measures: 4.00 x 2.00 x 1.40

CLP0224 SERIES 200 Watt Open Frame Power Supply Measures: 4.00 x 2.00 x 1.40 CLP0224 Open Frame Power Supply Applications Industrial equipment Telecommunications equipment Features Compact size 50.8 mm x 101.6 mm x 35.6 mm (2 in x 4 in x 1.4 in) with density of 18 W/in 3 Universal

More information

SPECIFICATION. For SWITCHING POWER SUPPLY M/N: MPD-F113-V

SPECIFICATION. For SWITCHING POWER SUPPLY M/N: MPD-F113-V SPECIFICTION For SWITCHING POWER SUPPLY M/N: MPD-F113-V Revision History REV. Oct. 1 st 2012 REV. Dec. 6 th 2012 REV. Jun. 4 th 2013 REV. Nov. 25 th 2015 Established Revised EMS performance and added mechanical

More information

Safety Standards. Model Number:

Safety Standards. Model Number: 100APS15 B Highlights & Features Safety Approvals to IEC 60601-1 3.1rd ed. & IEC 60950-1 Compliant with IEC 60601-1-2 4th Ed. Requirements Low touch current (

More information

C1U-W Tx Series

C1U-W Tx Series www.murata-ps.com PRODUCT OVERVIEW The C1U-W-1200 is a 1200 Watt universal AC input, power-factor-corrected (PFC) front-end power supply for general applications. The main output is 12V with a standby

More information

MPU-120S Series. Single Output, 180W Compact, U-Channel AC/DC Power Supplies. Key Features:

MPU-120S Series. Single Output, 180W Compact, U-Channel AC/DC Power Supplies.   Key Features: MPU-120S Series Single, 180W Compact, U-Channel AC/DC Power Supplies Key Features: 180W Power Universal 90-264 AC Power Factor Correction EN 60950 Approved Compact U-Channel Five Single Models Meets EN

More information

IEC/EN/UL60950 & CE certified, EN55032 Class B

IEC/EN/UL60950 & CE certified, EN55032 Class B Features Regulated Converter Universal input VAC 4W PCB mount package

More information

SFP450-12BG AC-DC Front-End Data Sheet 12V Output, 450 Watts

SFP450-12BG AC-DC Front-End Data Sheet 12V Output, 450 Watts Features RoHS compliant for all six substances Wide input voltage range (90-264 VAC) with PFC High power density, 9 Watts/cubic inch 1U or 2U height configurations Active current share with ORing FET I

More information

Series AMEL20-AZ 20 Watt AC-DC / DC-DC Converter

Series AMEL20-AZ 20 Watt AC-DC / DC-DC Converter FEATURES: Click on Series name for product info on aimtec.com Models Single output Model Input Voltage (/Hz) Input Voltage (VDC) Max wattage (W) Voltage (V) Current max (A) Maximum capacitive load (µf)

More information

VER05 Series. xxx Series. 5 Watt. AC-DC Power Supplies. Models & Ratings. Input. Output

VER05 Series. xxx Series. 5 Watt.   AC-DC Power Supplies. Models & Ratings. Input. Output 5 Watt xxx Series Energy Efficiency Level VI Barrel Jack & USB Versions Interchangeable Mains Connectors Included Universal Input Output Voltages from 5.0 V to 12.0 V Class II Construction Low Cost B R

More information

Features. Regulated Converter. RAC35-G/OF 35 Watt 4 x 2 Open Frame RAC35- SG/OF. AC/DC Converter

Features. Regulated Converter. RAC35-G/OF 35 Watt 4 x 2 Open Frame RAC35- SG/OF. AC/DC Converter Features Regulated Converter Description Universal input -264VAC Efficiency up to 86% Short circuit and over voltage/current protected UL/EN9 certified, CE marked Conformal coated product The RAC35-xxG/OF

More information

CPCI - 6U - DC - 350W

CPCI - 6U - DC - 350W Electrical Specification for: CPCI - 6U - DC - 350W Telkoor Part Number: 900-6001-0000 Approvals Name Date Written by: S. Sadot 13/3/08 Engineering: M. Heller 13/3/08 Sales & Marketing: B. Steinfeld 13/3/08

More information

REVISION HISTORY Rev Level Rev Date Change Made Reason for Change Effective Approved By A 13/12/08 Specification Release 13/12/08 S. Sadot A1 13/02/09

REVISION HISTORY Rev Level Rev Date Change Made Reason for Change Effective Approved By A 13/12/08 Specification Release 13/12/08 S. Sadot A1 13/02/09 Electrical Specification for: CPCI - 6U - DC - 600W Telkoor Part Number: 900-6113-0000 SCALE RELEASE DATE 13/12/08 SHEET 1 OF 7 REVISION HISTORY Rev Level Rev Date Change Made Reason for Change Effective

More information

ECF40 Series. 40 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details

ECF40 Series. 40 Watts.   AC-DC Power Supplies. Models & Ratings. Mechanical Details 40 Watts 40 W Convection Rating 1.5 by 3 Footprint Low 1.1 Profile High Efficiency Medical and ITE pprovals High Power Density Less than 0.15 W No Load Input Power 3 Year Warranty The ECF40 series is designed

More information

PMT. Model Number: Model Number Input Voltage Range Output Voltage Output Current PMT-5V350W1A (Selectable by Switch)

PMT. Model Number: Model Number Input Voltage Range Output Voltage Output Current PMT-5V350W1A (Selectable by Switch) PMT Highlights & Features AC input range selectable by switch Full Aluminium casing for light weight and corrosion resistant handling Built-in automatic fan speed control circuit Wide operating temperature

More information

Note1: Typ. efficiency is 230VAC and full load 12VDC 24VDC 48VDC ms 8ms 16ms 80ms

Note1: Typ. efficiency is 230VAC and full load 12VDC 24VDC 48VDC ms 8ms 16ms 80ms Features Regulated Converters Universal Input 9-264V Efficiency Up To 86% Short Circuit And Over Voltage/Current Protected UL/EN695 Certified, CE Marked Conformal Coated Product RECOM Connector Set Available

More information

MPM-U653-DCF-B M/N: MPM-U653-DCF-B. 650W Medical AC / DC SPECIFICATION FOR SWITCHING POWER SUPPLY. Revision History

MPM-U653-DCF-B M/N: MPM-U653-DCF-B. 650W Medical AC / DC SPECIFICATION FOR SWITCHING POWER SUPPLY. Revision History SPECIFICATION FOR SWITCHING POWER SUPPLY M/N: Revision History Version Date Change Items Rev. 1.0 July.21. 2017 Established. Page 1 Models & Ratings FEATURES 650W medical power supply with force air cooling.

More information

SPECIFICATION M/N: MPD-F For SWITCHING POWER SUPPLY. Revision History

SPECIFICATION M/N: MPD-F For SWITCHING POWER SUPPLY. Revision History SPECIFICTION For SWITCHING POWER SUPPLY M/N: MPD-F3- Revision History REV. Jan. 7 th 200 REV. Mar. 4 th 200 REV. Mar. 7 th 200 REV. Mar. 28 th 20 REV. Nov. 25 th 20 REV. Jul. 5 th 202 REV. Jun. 4 th 203

More information

Ripple & Noise (max) (See Note 2) 5V output: 100mVp-p; 12V - 27V outputs: 150mVp-p; 48V output: 200mVp-p

Ripple & Noise (max) (See Note 2) 5V output: 100mVp-p; 12V - 27V outputs: 150mVp-p; 48V output: 200mVp-p FEATURES 3 Year Warranty 100% Full Load Burn-In Tested Universal AC Input / Full Range Built-In Remote Sense Function Built-In Remote ON/OFF Control Current Sharing up to 2000W (3+1) Forced Air Cooling

More information

SPECIFICATION M/N: MPD-F For SWITCHING POWER SUPPLY

SPECIFICATION M/N: MPD-F For SWITCHING POWER SUPPLY SPECIFICTION For SWITCHING POWER SUPPLY M/N: MPD-F113-2 Revision History REV. Mar. 10 th 2011 Revised the value of inrush current. REV. Mar. 15 th 2011 Conformed the solution of EMI class B. REV. Mar.

More information

The SFP BG meets international safety requirements and is CE marked to the Low Voltage Directive (LVD). Datacom Distributed Power Systems

The SFP BG meets international safety requirements and is CE marked to the Low Voltage Directive (LVD). Datacom Distributed Power Systems Ideal server form factor optimizes, space, efficiency, and load variations High efficiency maximized between 30-80% load conditions Unconditionally stable under any load condition Wide input voltage range

More information

PART NUMBER STRUCTURE. P-DUKE Technology Co., Ltd Page 1

PART NUMBER STRUCTURE. P-DUKE Technology Co., Ltd Page 1 Medical Automation Datacom IPC Industry Measurement Telecom Automobile Boat Charger PV Railway PART NUMBER STRUCTURE M A D 100 U S 12 B - Application Package Dimension Output Input Output Output Protection

More information

Series MPM-X12Y 120W PFC MEDICAL POWER ADAPTER

Series MPM-X12Y 120W PFC MEDICAL POWER ADAPTER FEATURES 120W medical adapter with active PFC Green power CEC/Energy star group complied Designed to meet medical standard type BF rated Conductive EMI meets CISPR/FCC class B Wall mount mechanical construction

More information

48V 2KW 1U AC-DC Power Supply PS Electrical Specification for: Telkoor Model:

48V 2KW 1U AC-DC Power Supply PS Electrical Specification for: Telkoor Model: Electrical Specification for: Telkoor Model: 48V 2KW 1U AC-DC Power Supply PS-2048 SCALE RELEASE DATE 26/06/11 SHEET 1 OF 11 REVISION HISTORY Rev Level Rev Date Change Made Reason for Change Effective

More information

Efficiency (typ.) (Range) VDC VDC ma ma(typ.) ma (typ.) ma(typ.) VDC μf % MKW15-12S05M. Output Current Input Current Reflected Ripple

Efficiency (typ.) (Range) VDC VDC ma ma(typ.) ma (typ.) ma(typ.) VDC μf % MKW15-12S05M. Output Current Input Current Reflected Ripple FEATURES Industrial Standard 2" X 1" Package Wide 2:1 Input Range Fully Regulated Output I/O Isolation 40VAC with Reinforced Insulation, rated for 300VAC Working Low Leakage Current < 5µA Operating Ambient

More information

C1U-W Tx Series AC/DC Front End Power Supply

C1U-W Tx Series AC/DC Front End Power Supply www.murata-ps.com PRODUCT OVERVIEW The C1U-W-1200 is a 1200 Watt universal AC input, power-factor-corrected (PFC) front-end power supply for general applications. The main output is 48V with a standby

More information

Efficiency (typ.) Load VDC VDC ma ma(typ.) ma(typ.) μf %

Efficiency (typ.)  Load VDC VDC ma ma(typ.) ma(typ.) μf % FEATURES Smallest Encapsulated 10W Industrial Standard DIP16 Package Ultrawide 4:1 Input Voltage Range Fully Regulated Output Voltage I/O Isolation 1500VDC Operating Ambient Temp. Range 40 to 88 Low No

More information

ENGINEERING SPECIFICATION SHEET. Table of Contents 1 SCOPE ELECTRICAL SPECIFICATION...5

ENGINEERING SPECIFICATION SHEET. Table of Contents 1 SCOPE ELECTRICAL SPECIFICATION...5 Table of Contents 1 SCOPE...5 2 ELECTRICAL SPECIFICATION...5 2.1 INPUT REQUIREMENT... 5 2.1.1 Input voltage range... 5 2.1.2 Input frequency range... 5 2.1.3 AC inrush current... 5 2.1.4 Input current...

More information

The APR YE meets UL/CSA and all international safety requirements. It is SELV. Min Typ Max 90

The APR YE meets UL/CSA and all international safety requirements. It is SELV. Min Typ Max 90 APR-12-12-YE 12V Output, 12 Watts AC Front End FEATURES Wide input voltage range (9-264VAC) with active power factor correction Active current share Full protection; overvoltage, overcurrent and overtemperature

More information

-AC Input- Voltage/Current...AC V, 47-63Hz, 5.5A Max, 1 Phase. Fusing...AC 6.3A, 250V internal line fuse provided, non-user serviceable. Power F

-AC Input- Voltage/Current...AC V, 47-63Hz, 5.5A Max, 1 Phase. Fusing...AC 6.3A, 250V internal line fuse provided, non-user serviceable. Power F 1580 North Kellogg Drive Anaheim, Calif. 92807 Phone: (714) 917-0749 Fax: (714) 917-0786 HTL MODEL SERIES 200W 400W, Single and Multiple Outputs Features: 1 U High Hot Swap Power Supplies N + 1 Redundant

More information

VEL05 Series. xxx Series. 5 Watt. AC-DC Power Supplies. Models & Ratings. Input

VEL05 Series. xxx Series. 5 Watt.  AC-DC Power Supplies. Models & Ratings. Input 5 Watt xxx Series Energy Efficiency Level VI Barrel Jack & USB Versions Fixed Mains Connectors Universal Input Output Voltages from 5.0 V to 12.0 V Class II Construction Low Cost B R A N D The VEL05 series

More information

HEC-100RTN-48QSCA Rev A1.0

HEC-100RTN-48QSCA Rev A1.0 HEC100RTN48QSCA Rev A1.0 A. Features High Efficiency (Up to 90%). Active Power Factor Correction (Typical 0.96). Isolation Class I (With FG) AllRound Protection: OVP/SCP/OTP/OPP. Fully isolated Metal case

More information

PMT. Safety Standards. Model Number:

PMT. Safety Standards. Model Number: PMT Highlights & Features AC input range selectable by switch Full aluminium casing for light weight and corrosion resistant handling Built-in automatic fan speed control circuit MTBF > 700,000 hrs. as

More information

POWERBOX Medline 150 EBM04 Series W Single Output AC/DC Medical Switch Mode Adaptor, Desktop Style

POWERBOX Medline 150 EBM04 Series W Single Output AC/DC Medical Switch Mode Adaptor, Desktop Style Features Fulfills IEC60601-1-2:2014 (EMC 4th edition) Low safety ground leakage current Wide input range 90 to 264 VAC Optional output connectors 100% burn-in Overvoltage protection Overcurrent protection

More information

Output Voltage* (nom.)(adjustable)

Output Voltage* (nom.)(adjustable) Industrial Power Supplies TBLC Series, 6 90 W Low profile case, module depth only 55 mm Suitable for mounting in domestic installation panels Very high efficiency and low standby power -> compliance to

More information

PMT. Safety Standards. Model Number:

PMT. Safety Standards. Model Number: PMT Highlights & Features AC input voltage range selectable by switch Full aluminium casing for light weight and corrosion resistant handling Built-in automatic fan speed control circuit MTBF > 700,000

More information

GE Data Sheet 2.0. CLP0448 Open Frame Power Supply Vac input; 48/54Vdc output; 450W Output Power. Features. Applications.

GE Data Sheet 2.0. CLP0448 Open Frame Power Supply Vac input; 48/54Vdc output; 450W Output Power. Features. Applications. 2.0 Applications Industrial equipment Telecommunications equipment Description Features Compact size 76.2 mm x 127 mm x 35 mm (3 in x 5 in x 1.38 in) with density of 21.4 W/in 3 Universal AC Input Range

More information

Model Number: Model Number Input Voltage Range Rated Output Voltage Rated Output Current PMT-24V100W2AA Vac 24Vdc 4.50A

Model Number: Model Number Input Voltage Range Rated Output Voltage Rated Output Current PMT-24V100W2AA Vac 24Vdc 4.50A PMT2 Highlights & Features Safety approvals : IEC60950-1,IEC 60335-1, IEC 61558-1 and IEC 61558-2-16 High line AC input range: 170-264Vac No load power consumption < 0.21W Low profile design : 30mm height

More information

EPT W 5V 2.4A ±5% EPT W 7V 1.71A ±5% EPT W 9V 1.5A ±5% EPT W 12V 1.25A ±5% EPT W 15V 1.0A ±5%

EPT W 5V 2.4A ±5% EPT W 7V 1.71A ±5% EPT W 9V 1.5A ±5% EPT W 12V 1.25A ±5% EPT W 15V 1.0A ±5% 15 Watts US DoE Energy efficiency level VI Interchangeable input plugs Class II Single outputs 5 to 48V EN55022 Level B conducted & radiated 5 Year warranty The EPT15 range of wall plug adaptors are compliant

More information

Chrome Class II DIN Rail Power Supply 24V 10W 1 Phase (NEC Class 2 & Household) / DRC-24V10W1HZ

Chrome Class II DIN Rail Power Supply 24V 10W 1 Phase (NEC Class 2 & Household) / DRC-24V10W1HZ Highlights & Features Protection Class II, Double Isolation (No Earth connection is required) Household appliance approvals IEC/EN 60335-1 4kV Electrical Fast Transient / Burst Universal AC input voltage

More information

Series MPM-815H 150W PFC MEDICAL ATX POWER SUPPLY

Series MPM-815H 150W PFC MEDICAL ATX POWER SUPPLY 50W PFC MEDICAL ATX POWER SUPPLY FEATURES +5V Stand-by and Remote ON/OFF U, 50W convection cooled with ATX Input Active PFC for medical purpose Power good / Power fail signal Thermal protection EN 6060-,

More information

Universal input VAC <150mW No load power consumption

Universal input VAC <150mW No load power consumption Features Regulated Converter Description Universal input 85-64VAC

More information

48V 1.5KW 1U AC-DC Power Supply Electrical Specification for: Telkoor Model: 0/ 7 SHEET 1 OF 1

48V 1.5KW 1U AC-DC Power Supply Electrical Specification for: Telkoor Model: 0/ 7 SHEET 1 OF 1 Electrical Specification for: 48V 1.5KW 1U AC-DC Power Supply Telkoor Model: 900-1548-0000 0/ 7 SHEET 1 OF 1 REVISION HISTORY Rev Level A B Rev Date Change Made Reason for Change Effective Approved 22/06

More information

GSP750 Series. 750 Watts. AC-DC Power Supplies. Models & Ratings. Input

GSP750 Series. 750 Watts.   AC-DC Power Supplies. Models & Ratings. Input C-DC Power Supplies 750 Watts 900 W Peak Power Rating for 100 ms Universal 80-264 VC Input IT & Medical Safety pprovals 1.0 W Standby Power -40 C to +70 C Operation Remote On/Off 5 V/3 Standby Output 3

More information