Audia. AudiaFUSION. Manual

Size: px
Start display at page:

Download "Audia. AudiaFUSION. Manual"

Transcription

1 Audia AudiaFUSION Manual Biamp Systems 9300 S.W. Gemini Drive Beaverton, OR USA

2 IMPORTANT SAFETY INSTRUCTIONS

3 table of contents audiafusion FEATURES... 3 front panel Setup and Use System Indicators Chassis Indicators rear panel Serial Control Port Power Entrance... 6 NM Logic I/O... 6 Ethernet CobraNet Output Amplifier-to-Amplifier Failover Channel-to-Channel Failover AudiaFUSION & CARD specifications VAC Current Draw and Heat Output Block diagram warranty

4 audiafusion alarm activity signal 1 signal 2 status ais power AudiaFUSION is the newest member of the Audia family, bringing together open-architecture DSP, Multi-Channel Amplifier technology, and device- and load-monitoring capabilities. AudiaFUSION features an 8-channel modular amplifier, 16x16 I/O via CobraNet and DSP with support for channel-to-channel and device-to-device failover. AudiaFUSION can support up to 8 amplifier cards that are individually software configurable from watts for up to 2400 watts of power, with software-selectable 70V, 100V and low impedance outputs per card. Intuitive software provides audio system design via PC and allows easy selection, viewing and calibration of numerous audio components: mixers, combiners, matrixes, equalizers, filters, crossovers, dynamics, routers, delays, meters, generators, diagnostic tools, and more. Once a system design is compiled, it is downloaded into AudiaFUSION, where it can be controlled via AMX, Crestron, other third-party control system, or via computer running davinci control software. When installed in a system together, AudiaFLEX and Audia- FUSION processing resources are allocated as needed, making the whole system more efficient.. FEATURES Modular based design Amplification modules have software configurable power levels/load options 8 amplification modules per frame with 100W to 600 Watts per module (maximum of 2400W per chassis) 70 V or 100 V with direct drive capability, or low-impedance (4 or 8Ω) operation Maximum of 2400 watts of power in 3 rack unit device TCP/IP Network controllable LED Indication: Signal present Peak present Clip present Heat sink temperature fault Amplifier failure Fan stuck-rotor Internal amplifier module failover mode Entire device failover mode Software Monitoring Features: Peak present Heatsink temperature value, warning and fault Short circuit on output Amplifier failure Impedance min/max threshold warning Excessive clipping Fan stuck-rotor Seamless integration with CobraNet-enabled Audia systems CobraNet Interface (16 channels in/16 channels out) CobraNet latency 5-1/3, 2-2/3 or 1-1/3 ms, software configurable Dual Ethernet ports for redundancy Selectable 115/230 volt operation Control via RED-1, davinci or third party control systems CE marked, UL listed and RoHS compliant Covered by Biamp Systems five-year warranty 3

5 audiafusion front panel Setup and Use The Audia software provides the interface for configuring and programming AudiaFUSION. The information supplied by this manual relates to hardware installation, physical connections, and device and channel failover concerns. For more details on software setup, please consult the Audia software Help File. Figure 1. Front Panel alarm activity signal 1 signal 2 status ais power System Indicators The LED indicators on the front panel provide information about the function and operational status of the AudiaFUSION chassis and any installed amplifier modules. Columns one through eight correspond to the eight amplifier module slots. The remaining LEDs correspond to the AudiaFUSION chassis. Figure 2. System Indicators alarm activity signal 1 status signal 2 ais power Channel Indicators Chassis Indicators Channel Indicators Alarm is a two-color LED that illuminates when a channel fault has occurred. Two types of channel faults can be reported, depending on the severity of the problem. Amber indicates a Warning, which means that some aspect of the amplifier module is not performing within normal specification. Audio may still be passing, but if the condition causing the Warning is not corrected, channel failure may occur. Red indicates an Alarm, which means that some aspect of the amplifier module has failed and audio is no longer passing on that channel. Use the Audia software to determine the specific type of channel warning or alarm that has occurred. Activity is a two-color LED that illuminates in green when the channel is configured and actively passing audio and amber when the channel is configured and in standby. Standby only occurs when a channel has been designated as a secondary failover channel in the configuration. 4

6 audiafusion front panel Signal 1 is a tri-color LED that indicates audio signal presence on the channel. Green indicates that the audio signal level is between -50 dbfs and -3 dbfs, amber indicates a signal level between -3 dbfs and 0 dbfs, and red indicates clipping. Signal 2 has no function at this time and is in place for possible future use. Chassis Indicators Alarm is a two-color LED that illuminates when a chassis fault has occurred. Two types of chassis faults can be reported, depending on the severity of the problem. Amber indicates a Warning, which means that some aspect of the AudiaFUSION chassis is not performing within normal specification. Audio may still be passing, but if the condition causing the Warning is not corrected, chassis failure may occur. Red indicates an Alarm, which means that some aspect of the AudiaFUSION chassis has failed and audio may no longer be passing through the device. Use the Audia software to determine the specific type of chassis warning or alarm that has occurred. Activity is a tri-color LED that illuminates to show the configuration status of the AudiaFUSION unit. If the LED is dark, there is no configuration in the unit. A green LED indicates that the unit is configured, and an amber LED indicates that the unit is configured and in standby. Standby only occurs when a unit has been designated as a secondary failover device in the configuration. A red LED indicates a configuration load failure. Status is a tri-color LED that indicates the health of the AudiaFUSION hardware. A green LED indicates that the unit powered up normally. A flashing amber LED is shown briefly during the power-on self test and should turn solid green upon a successful start up. A red LED indicates that the unit experienced a problem during the power-on self test. AIS has no function at this time and is in place for possible future use. Power is a green LED that illuminates when power is applied to the unit. 5

7 RISK OF ELECTRICAL SHOCK. DO NOT OPEN. audiafusion rear panel Figure 3. Rear Panel Layout SERIAL CONTROL PORT BIAMP SYSTEMS MODEL AudiaFUSION FUSE 115V FUSE / V~ 50/60Hz 2400WAT T CAUTION V: T 12 H, 250V V: T 20 H, 250V NM-1 Secondary YEL: In use/conductor GRN: Link/Activity CobraNet Connections Only Primary Ethernet Logic I/O LEDs 52SJ Serial Control Port After initial programming and configuration, AudiaFUSION may be controlled by third-party control systems such as AMX or Crestron using the Serial Control Port. External devices may also be controlled or signaled via the Serial Control Port by utilizing Command String blocks within the Audia system design. The port is a DB9 female with pin 2 [RXD], pin 3 [TXD], and pin 5 [GND] connected. AudiaFUSION is an RS-232 DCE device. The default settings are 38400, 8, N, 1, None. The baud rate is adjustable in the Audia software using the Device Maintenance dialog window. The other serial port settings are not adjustable. Please note: There is no hardware flow control. Flow control must be managed in control software. Power Entrance The Power Entrance provides for connection of the appropriate power cord (included with unit). A switch selects the operating voltage for the power supply, V or V at 50/60 Hz. NM-1 NM-1 is the Network Module that is included with AudiaFUSION. It provides Ethernet connectivity for programming and control, the CobraNet interface for digital I/O, and logic ports for the device failover functionality. Reset Button Reset button, when held down for 5 seconds, performs a chassis restart. The Status indicator will flash amber during restart and will turn solid green once the process is complete. Logic I/O The Logic I/O connector on the NM-1 facilitates redundant device failover only. It is not a general-purpose contact closure interface. See the Amplifier-to-Amplifier Failover section below. Ethernet AudiaFUSION uses Ethernet for system programming and control. Programming is accomplished using Audia software provided with each unit. Audia software is for PC computers with Windows XP Professional/Vista operating system (required). The PC computer must have a network card installed that supports 10/100Base-T Ethernet. A 10/100Base-T Ethernet switch (not repeater hub) is required when networking multiple units. AudiaFUSION uses standard CAT5, CAT5e, CAT6, or CAT7 cabling, which has a specified maximum length of 100 meters. Additional Ethernet switches and/or fiber-optic cable can be used to further extend distances between units on a network. CobraNet The CobraNet interface in AudiaFUSION supports up to 32 simultaneous channels of digital audio (16-in, 16-out) over Fast Ethernet and is compatible with other CobraNet compliant devices. Therefore, AudiaFUSION can be networked with CobraNet products from other manufacturers, expanding the system configuration capabilities. A 10/100Base-T Ethernet switch (not repeater hub) is required when networking multiple units. CobraNet utilizes standard CAT5, CAT5e, CAT6, or CAT7 cabling, which has a specified maximum length of 100 meters. Additional Ethernet switches and/or fiber-optic cable can be used to further extend distances between units on a network. 6

8 audiafusion rear panel Please note that CobraNet limits network extensions to seven hops (one-way transmissions) within a network. The primary and secondary CobraNet ports are redundant. Each connector provides two LEDs that indicate Ethernet link and network activity (see table below). Table 1. CobraNet interface status LEDs Left LED Right LED Description None None No data connectivity.. Green None Link established. Green Flashing green Flashing amber Flashing amber Flashing amber Flashing amber Link established and CobraNet activity detected; the unit is acting as a CobraNet performer. Link established and CobraNet activity detected; the unit is operating as a CobraNet conductor. CobraNet fault. Check cabling and configuration for errors. is the Amplifier Module card. An AudiaFUSION chassis can be populated with up to eight cards. Output Use the yellow plug-in barrier strip connectors to connect loudspeaker level outputs. If stranded speaker wire is used, be sure to incorporate all strands into the connector, as stray strands can short to the adjacent terminal or chassis. Do not leave excessive bare wire outside the terminals, as this can lead to shorts. Please note: AudiaFUSION is a powerful amplifier and can damage loudspeakers. Please treat the outputs as you would AC mains power outlets. Always check the loudspeaker s continuous and peak power capabilities and match the amplifier settings accordingly. 7

9 audiafusion rear panel Amplifier-to-Amplifier Failover AudiaFUSION supports one-to-one automatic device failover in case of fault. Failover is triggered by one of the following conditions: Chassis alarm Channel alarm Loss of power Loss of CobraNet link Loss of Logic I/O Only alarms (e.g., heat sink alarm and channel failure alarm) trigger the failover mechanism. Warnings indicate abnormal system conditions that do not immediately impair audio and do not trigger the failover mechanism. The redundant amplifier must have the same configuration as the primary amplifier (i.e., amplifier module count, watts per module, load configuration). A wire failover link cable must be connected between the primary and the redundant amplifier as shown below. Connect ground to ground and logic 4 of the primary amplifier to logic 3 of the redundant amplifier; connect logic 3 of the primary amplifier to logic 4 of the redundant amplifier. Leave logic 1 and 2 disconnected. Primary AudiaFUSION Logic I/O Logic I/O Redundant AudiaFUSION The redundant amplifier can be wired in parallel to the existing speaker line or connected to a redundant speaker line (see figure below). Relays isolate the output terminals on the secondary AudiaFUSION unit. Relays are normally open. When a configuration is received, relays close on the primary AudiaFUSION and remain open on the redundant AudiaFUSION. On failover, the relay positions are reversed. Parallel Wiring Redundant Wiring Primary AudiaFUSION Primary AudiaFUSION Redundant AudiaFUSION Redundant AudiaFUSION After replacing the faulty amplifier, a power cycle is required to recover from failover. The primary device will resume control after the fail condition is cleared and the unit is re-powered. 8

10 audiafusion rear panel Channel-to-Channel Failover In addition to entire amplifier failover, AudiaFUSION supports channel-to-channel failover, which is triggered by one of the following conditions: Heat Sink alarm Short Circuit alarm* Channel Failure alarm The wire failover link cable is not required when wiring channel-to-channel failover. Parallel Wiring Redundant Wiring Redundant Primary The redundant channel can be wired in parallel to the existing speaker line (shown above) or connected to a redundant speaker line. The primary amplifier module will resume control after the fault condition is cleared and the unit is re-powered. * A Short Circuit alarm will cause failover only if the Persistent Short Circuit Delay time property in the AudiaFUSION is exceeded. 9

11 audiafusion specifications AudiaFUSION SPECIFICATIONS Inputs: Connection: 20 bits, 48 khz, supported CobraNet latency 5-1/3, 2-2/3 or 1-1/3 ms software configurable RJ45 with shielded Ethernet cable (Cat5, Cat5e, Cat6, or Cat7) Overall Dimensions: Height: Width: Depth: Weight: Chassis: card: 5.25 inches (133mm) 19 inches (483mm) inches (438mm) 50 lbs. (22.68 kg) 1.25 lbs. (0.57 kg) Environment: Ambient Operating Temperature Range: Ambient intake humidity: Altitude: degrees F (0 35 C) 0 100% non-condensing 0 10,000 Feet MSL Compliance: EU Directive 2002/95/EC, RoHS directive UL listed CE marked Power: 110~120 & 220~240 VAC 50/60Hz switch selectable 1. In chassis with fans running normally and unrestricted intake and exhaust Card SPECIFICATIONS Supported Loads: 4Ω 8Ω, 70-Volt Line, or 100-Volt line direct drive 6Ω not shown in GUI Frequency response: 20 Hz 20 khz frequency response flat (+/-1 db) Continuous operation: (in chassis with fans running normally and unrestricted intake and exhaust) 400 W: 1 khz continuous sine wave indefinitely 600 W: 1 khz continuous sine wave for at least 3 minutes 2400 Watt maximum per chassis Distortion and Noise: 0.3% THD+N (20 Hz 20k Hz) all loads and power levels Signal-to-Noise Ratio: (unweighted over 22 Hz 20 khz) 100W 200W 300W 400W 500W 600W Lowimpedance 70V 100V >95 db >100 db >101 db >98 db >101 db >102 db >99 db >101 db >102 db >101 db >102 db >103 db >102 db >102 db >103 db >102 db >103 db >104 db Intermodulation distortion (SMPTE): <0.2% Inter-channel Isolation: DC offset: >75 db (20 Hz-20 khz, full power out) <10mV 10

12 audiafusion specifications AudiaFUSION Block Diagram NETWORK MODULE AMPLIFIER CARD DSP SLOT 1 SLOT 2 SLOT 3 SLOT 4 SLOT 5 SLOT 6 SLOT 7 SLOT 8 DSP CLASS D AMPLIFIER DC DETECTION TEMPERATURE CobraNet Audio CobraNet IMPEDANCE MONITORING I V Ethernet Control 10/100 ETHERNET uc Serial I/O Logic I/O RS-232 LOGIC Display FAN CONTROL FAN 1 FAN 2 11

13 audiafusion specifications AudiaFUSION 115 VAC current draw and heat output To determine the AC line current draw and heat output for the configuration, start by finding the total power for the configured AudiaFUSION chassis. Then refer to the column that describes the type of audio levels the amplifier will be producing. If your configuration uses more amplifier modules than the number shown, add 0.1 amps and 37 BTU for each additional module in the chassis. Configured Output Power (watts) Idle 1/8 power pink noise 1/3 power pink noise Full power sine wave Number of cards* Amps BTU Amps BTU Amps BTU Amps BTU No cards NA NA NA NA NA NA * * * * * * 3325 For each additional used in a chassis adds 37 BTU or 10 watts to the heat output. For 230 VAC, multiply the current by 0.5. * Burst mode only. Protective limiting will reduce long-term AC current B 12

14 audiafusion warranty BIAMP SYSTEMS IS PLEASED TO EXTEND THE FOLLOWING 5-YEAR LIMITED WARRANTY TO THE ORIGINAL PURCHASER OF THE PROFESSIONAL SOUND EQUIPMENT DESCRIBED IN THIS MANUAL 1. BIAMP Systems warrants to the original purchaser of new products that the product will be free from defects in material and workmanship for a period of 5 YEARS from the date of purchase from an authorized BIAMP Systems dealer, subject to the terms and conditions set forth below. 2 If you notify BIAMP during the warranty period that a BIAMP Systems product fails to comply with the warranty, BIAMP Systems will repair or replace, at BIAMP Systems option, the nonconforming product. As a condition to receiving the benefits of this warranty, you must provide BIAMP Systems with documentation that establishes that you were the original purchaser of the products. Such evidence may consist of your sales receipt from an authorized BIAMP Systems dealer. Transportation and insurance charges to and from the BIAMP Systems factory for warranty service shall be your responsibility. 3. This warranty will be VOID if the serial number has been removed or defaced; or if the product has been altered, subjected to damage, abuse or rental usage, repaired by any person not authorized by BIAMP Systems to make repairs; or installed in any manner that does not comply with BIAMP Systems recommendations. 4. Electro-mechanical fans, electrolytic capacitors, gooseneck microphones, cords connecting handheld microphones, hard-drives, displays, and normal wear and tear of items such as paint, knobs, handles, keypads and covers are not covered under this warranty. All server-based devices are warranted for 3 years only. 5. This warranty is in lieu of all other warranties, expressed or implied. Biamp Systems disclaims all other warranties, expressed or implied, including, but not limited to, implied warranties of merchantability and fitness for a particular purpose. 6. The remedies set forth herein shall be the purchaser s sole and exclusive remedies with respect to any defective product. 7. No agent, employee, distributor or dealer of Biamp Systems is authorized to modify this warranty or to make additional warranties on behalf of Biamp Systems. Statements, representations or warranties made by any dealer do not constitute warranties by Biamp Systems. Biamp Systems shall not be responsible or liable for any statement, representation or warranty made by any dealer or other person. 8. No action for breach of this warranty may be commenced more than one year after the expiration of this warranty. 9. Biamp systems shall not be liable for special, indirect, incidental, or consequential damages, including lost profits or loss of use arising out of the purchase, sale, or use of the products, even if biamp Systems was advised of the possibility of such damages. 13

15 DoC DSPA EC Declaration of Conformity Biamp Systems Corporation, as manufacturer having sole responsibility, hereby declares that the following described product complies with the applicable provisions of the DIRECTIVES below except as noted herein. Any alterations to the product not agreed upon and directed by Biamp Systems Corporation will invalidate this declaration. Product Models: I/O Cards: Controls: Audia Series AEC-2HD Logic Box DSP Platforms:, -600C RED-1 AudiaFLEX IP-2, OP-2e Remote Control Bus Hub AudiaFUSION PA-2 Remote Panels; RP-L1, RP-L2, RP-S4 AudiaSOLO TI-2 Select 8, Volume 8, Volume/Select 8 VoIP-2 Voltage Control Box Product Description: Applicable EC Directives: Audio Digital Signal Processors and Control Accessories Applicable Harmonized Standards: LVD Directive (2006/95/EC) Safety EN 60065:2002 EMC Directive (2004/108/EC) Emissions EN :1996, Environment E2 Immunity EN :1996 R&TTE Directive (1999/5/EC) Terminal Equipment (AudiaFLEX with TI-2 only) Special Considerations for Product Environment or Compliance: Shielded cabling must be used for system connections. RED-1, use only CE marked Power over Ethernet (PoE) device. Technical Documentation File, Location and Contact: Biamp Systems, Inc. phone: (503) S.W. Gemini Drive fax: (503) Beaverton, OR USA biamp@biamp.com Authorized Representative: Larry Copley, Compliance Engineer Authorized Signature: Issued: March, 2010

16 compliance 15

17 IMPORTANT SAFETY INSTRUCTIONS 16

18 IMPORTANT SAFETY INSTRUCTIONS 17

19 IMPORTANT SAFETY INSTRUCTIONS 18

Vocia ELD-1. Operation Manual

Vocia ELD-1. Operation Manual Vocia Operation Manual Biamp Systems 9300 S.W. Gemini Drive, Beaverton, Oregon 97008 U.S.A. (503) 641-7287 www.biamp.com table of contents Vocia End of Line Device () features....3 setup and use...............................................................................

More information

Vocia. Page Active Relay Module (PARM-1) Operation Manual

Vocia. Page Active Relay Module (PARM-1) Operation Manual Vocia Page Active Relay Module (PARM-1) Operation Manual Biamp System 9300 SW Gemini Drive, Beaverton, OR 97008 U.S.A. (503) 641-7287 www.biamp.com table of contents Vocia Page Active Relay Module (PARM-1)

More information

RT Remote Translator and. WMC, IR-T, & RIK Controls

RT Remote Translator and. WMC, IR-T, & RIK Controls TM RT Remote Translator and WMC, IR-T, & RIK Controls Operation Manual TABLE OF CONTENTS Connections RS- Remote Controls Application Warranty CE Documents Safety Information pg. pg. pg. pg. pg. INTRODUCTION

More information

iconverter 2-Module Power Chassis

iconverter 2-Module Power Chassis iconverter 2-Module Power Chassis User Manual 38 Tesla, Irvine, CA 92618 USA Phone: (949) 250-6510; Fax: (949) 250-6514 Page 1 Warning The operating description in this Instruction Manual is for use by

More information

MAINTENANCE MANUAL. EDACS REDUNDANT POWER SUPPLY SYSTEM 350A1441P1 and P2 POWER MODULE CHASSIS 350A1441P3, P4, AND P5 POWER MODULES TABLE OF CONTENTS

MAINTENANCE MANUAL. EDACS REDUNDANT POWER SUPPLY SYSTEM 350A1441P1 and P2 POWER MODULE CHASSIS 350A1441P3, P4, AND P5 POWER MODULES TABLE OF CONTENTS MAINTENANCE MANUAL EDACS REDUNDANT POWER SUPPLY SYSTEM 350A1441P1 and P2 POWER MODULE CHASSIS 350A1441P3, P4, AND P5 POWER MODULES TABLE OF CONTENTS SPECIFICATIONS*... 2 INTRODUCTION... 3 DESCRIPTION...

More information

EIDX_M Series INSTALLATION GUIDE INTRODUCTION. A Line of Managed Ethernet Switching Hubs

EIDX_M Series INSTALLATION GUIDE INTRODUCTION. A Line of Managed Ethernet Switching Hubs EIDX_M Series A Line of Managed Ethernet Switching Hubs INTRODUCTION INSTALLATION GUIDE The EIDX_M Series of managed Industrial Ethernet switches provides the user with a sophisticated instrument with

More information

Automated Tuner System Power Distribution Hub

Automated Tuner System Power Distribution Hub User Guide Automated Tuner System Power Distribution Hub Model MT1020B MT1020-340 (Rev B) 12/11 User Guide Automated Tuner System Power Distribution Hub Model MT1020B 2900 Inland Empire Boulevard Ontario,

More information

PS8 - II. Professional Power Sequencer. User s Manual

PS8 - II. Professional Power Sequencer. User s Manual PS8 - II Professional Power Sequencer User s Manual IMPORTANT SAFETY INSTRUCTIONS READ FIRST This symbol, whenever it appears, alerts you to the presence of uninsulated dangerous voltage inside the enclosure.

More information

USB Ranger Fiber Optic USB 2.0 Extender. User Guide

USB Ranger Fiber Optic USB 2.0 Extender. User Guide USB Ranger 2224 Fiber Optic USB 2.0 Extender User Guide Thank you for purchasing the USB Ranger 2224. Please read this guide thoroughly. This document applies to Part Numbers: 00-00260, 00-00261, 00-00262,

More information

A Line of Fixed-Port Industrial Ethernet 10/100 Mbps Switches INSTALLATION GUIDE

A Line of Fixed-Port Industrial Ethernet 10/100 Mbps Switches INSTALLATION GUIDE EISwitch A Line of Fixed-Port Industrial Ethernet 10/100 Mbps Switches INTRODUCTION INSTALLATION GUIDE The EIS series Ethernet Interconnect Switch in the CTRLink family provides a solution for those industrial

More information

HPA4202 1/5. 2-Channel High Power Multi-Impedance Amplifier. General Description. Features. Applications. AtlasIED.com. HPA4202 Front.

HPA4202 1/5. 2-Channel High Power Multi-Impedance Amplifier. General Description. Features. Applications. AtlasIED.com. HPA4202 Front. 1/5 HPA4202 2-Channel High Power Multi-Impedance Amplifier Features 70.7V/100V and 2Ω, 4Ω, and 8Ω Output 100V 70.7V 8Ω 2 x 1200W 4Ω 2Ω 2 x 2500W 8Ω BRIDGED 1 x 3800W 4Ω BRIDGED 1 x 4800W Balanced Inputs

More information

Enhanced Mini-Chansim Model VCS-232

Enhanced Mini-Chansim Model VCS-232 Enhanced Mini-Chansim Model VCS-232 Operations Manual ViaSat Inc. 6155 El Camino Real Carlsbad, CA 92009 http://www.viasat.com SAFETY WARNING Always observe standard safety precautions during installation,

More information

DATA SHEET TESIRA TCM-1 AVB BEAMTRACKING CEILING MICROPHONE

DATA SHEET TESIRA TCM-1 AVB BEAMTRACKING CEILING MICROPHONE DATA SHEET TESIRA TCM-1 AVB BEAMTRACKING CEILING MICROPHONE The TCM-1 is an AVB ceiling microphone for use in Tesira systems. Comprising a pendant microphone and plenum box, each microphone includes Beamtracking

More information

USB 2.0 Ranger Port USB m CAT 5e/6/7 Extender System. User Guide

USB 2.0 Ranger Port USB m CAT 5e/6/7 Extender System. User Guide USB 2.0 Ranger 2304 4-Port USB 2.0 100m CAT 5e/6/7 Extender System User Guide Thank you for purchasing the USB 2.0 Ranger 2304. Please read this guide thoroughly. This document applies to Part Numbers:

More information

Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual

Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual Omnitron Systems Technology, Inc. 1 iconverter 19-Module Managed Power Chassis User s Manual 27 Mauchly, #201, Irvine, CA 92618 Phone: (949) 250-6510; Fax: (949) 250-6514 2 Omnitron Systems Technology,

More information

MTS-2000 USER S MANUAL

MTS-2000 USER S MANUAL MTS-2000 USER S MANUAL USER s MANUAL - March 2010 MTS-2000 METER TEST SYSTEM Pay special attention to the warnings and safety instructions that accompany the above symbol wherever it is found within this

More information

V-9908 MESSAGE/PAGE PANEL

V-9908 MESSAGE/PAGE PANEL Issue 4 V-9908 MESSAGE/PAGE PANEL Introduction These instructions contain the specifications and guidelines necessary to install, operate, and maintain the V-9908, /Page Panel. The V-9908 /Page Panel provides

More information

500 Business Center Drive Pittsburgh, PA USA CAGE 1BGJ7. SwitchMaster R5000 Series Ultra-Compact Ganged A/B Switching System

500 Business Center Drive Pittsburgh, PA USA CAGE 1BGJ7. SwitchMaster R5000 Series Ultra-Compact Ganged A/B Switching System Market Central www.secureswitch.com 500 Business Center Drive Pittsburgh, PA 15205 USA 412.494.2800 CAGE 1BGJ7 SwitchMaster R5000 Series Ultra-Compact Ganged A/B Switching System July, 2014 COMPLETE 2

More information

Zonit μats TM Users Guide μats1-lv Version 1.2

Zonit μats TM Users Guide μats1-lv Version 1.2 Zonit μats TM Users Guide μats1-lv Version 1.2 Table of Contents Product Overview...2 Pre-Installation Considerations...2 Product Features...3 Installation...4 Optional Accessories...4 μats TM Operational

More information

TitanONE Smart Mainframe Power Amplifier

TitanONE Smart Mainframe Power Amplifier 1/7 TitanONE Smart Mainframe Power Amplifier T112 General Description The AtlasIED TitanONE T112 Smart Mainframe Power Amplifier provides the latest signal automation, processing and amplification technologies

More information

CMSA-100 Manual. Cinema Media Server Automation

CMSA-100 Manual. Cinema Media Server Automation CMSA-100 Manual Cinema Media Server Automation 181 Bonetti Drive San Luis Obispo, CA 93401-7397 USA Phone: +1 805 549 0161 Fax: +1 805 549 0163 www.uslinc.com Table of Contents 1. Safety Notice... 3 2.

More information

USB Ranger 422 User Guide

USB Ranger 422 User Guide USB Ranger 422 User Guide Featuring ExtremeUSB Technology USB Ranger 422 Thank you for purchasing the USB Ranger. Please read this guide thoroughly before installation. This document applies to Part Numbers:

More information

USB Ranger 110/410 User Guide

USB Ranger 110/410 User Guide USB Ranger 110/410 User Guide Featuring ExtremeUSB Technology USB Ranger 110/410 Thank you for purchasing the USB Ranger. Please read this guide thoroughly before installation. This document applies to

More information

1x4 HDMI & Full 3D support over Single CAT5 Distribution Amplifier with Local Output. User Manual

1x4 HDMI & Full 3D support over Single CAT5 Distribution Amplifier with Local Output. User Manual SP-5105KC 1x4 HDMI & Full 3D support over Single CAT5 Distribution Amplifier with Local Output User Manual To avoid EMI issue, complete STP Cat6 cable is strongly recommended! rev: 131028 Made in Taiwan

More information

USB Ranger User Guide. Cat 5 USB 2.0 Extender with Remote Power. Powered by

USB Ranger User Guide. Cat 5 USB 2.0 Extender with Remote Power. Powered by USB Ranger 2212 Cat 5 USB 2.0 Extender with Remote Power User Guide Powered by Thank you for purchasing the USB Ranger 2212. Please read this guide thoroughly. This document applies to Part Numbers: 00-00252,

More information

OPR Power Series AC to DC POWER SUPPLY SERIES WITH REMOTE MANAGEMENT AND ALARM SYSTEMS. Model Nos. OPR065-48S / OPR065-48R. Manual

OPR Power Series AC to DC POWER SUPPLY SERIES WITH REMOTE MANAGEMENT AND ALARM SYSTEMS. Model Nos. OPR065-48S / OPR065-48R. Manual OPR Power Series AC to DC POWER SUPPLY SERIES WITH REMOTE MANAGEMENT AND ALARM SYSTEMS Model Nos. OPR065-48S / OPR065-48R Manual Revision F July 2009 Optimal Power Supplies LLC www.optimal-power.com i

More information

Vocia. VA-8600/VA-8600c. Manual

Vocia. VA-8600/VA-8600c. Manual Vocia VA-8600/VA-8600c Manual January 2012 Biamp Systems, 9300 SW Gemini Drive, Beaverton, Oregon 97008 U.S.A. (503) 641-7287 www.biamp.com IMPORTANT SAFETY INSTRUCTIONS 1) Read these instructions. 2)

More information

SM-10 SM-20-A. Sound Level Meters. Users Manual. For detailed specifications and ordering info go to

SM-10 SM-20-A. Sound Level Meters. Users Manual. For detailed specifications and ordering info go to SM-10 SM-20-A Sound Level Meters Users Manual For detailed specifications and ordering info go to www.testequipmentdepot.com SM-10 / SM-20-A Sound Level Meters English Users Manual SM10_Rev002 2009 Amprobe

More information

16/24 Port 10/100 Auto-Sensing Dual Speed Ethernet Switch

16/24 Port 10/100 Auto-Sensing Dual Speed Ethernet Switch 12 Omnitron Systems Technology, Inc. Omnitron Systems Technology, Inc. 1 FlexSwitch TM 600X 16/24 Port /0 -Sensing Dual Speed Ethernet Switch User s ual 27 Mauchly #201, Irvine, CA 92618 (949) 250-65 Fax:

More information

Installation Manual SM-RS Port RS232 Router with optional TCP/IP control

Installation Manual SM-RS Port RS232 Router with optional TCP/IP control Installation Manual SM-RS232 16-Port RS232 Router with optional TCP/IP control Control up to 16 RS232 compliant devices up to 50 feet away over UTP or from anywhere via TCP/IP (optional) What s in the

More information

HDX II Owner s Manual Modular Fiber Optic HDMI Extender

HDX II Owner s Manual Modular Fiber Optic HDMI Extender HDX II Owner s Manual Modular Fiber Optic HDMI Extender PureLink TM 535 East Crescent Avenue Ramsey, NJ 07446 USA Tel: +1.201.488.3232 Fax: +1.201.621.6118 E-mail: sales@purelinkav.com www.purelinkav.com

More information

SPM723 Programmable Stereo Preamp/Mixer Operation Manual

SPM723 Programmable Stereo Preamp/Mixer Operation Manual SPM723 Programmable Stereo Preamp/Mixer Operation Manual Biamp Systems, 10074 S.W. Arctic Drive, Beaverton, Oregon 97005 U.S.A. (503) 641-7287 www.biamp.com an affiliate of Rauland-Borg Corp. print update

More information

Vocia. VA-8600 Failover Module (VFOM-1) Installation Guide

Vocia. VA-8600 Failover Module (VFOM-1) Installation Guide Vocia VA-8600 Failover Module (VFOM-1) Installation Guide Biamp Systems, 9300 S.W. Gemini Drive, Beaverton, Oregon 97008, U.S.A. (503) 641-7287 www.biamp.com VA-8600 FAILOVER MODULE 1 (VFOM-1) The Vocia

More information

USER MANUAL. MODEL 1052 idsl Modem with RS-232 Interface. An ISO-9001 Certified Company SALES OFFICE (301) TECHNICAL SUPPORT (301)

USER MANUAL. MODEL 1052 idsl Modem with RS-232 Interface. An ISO-9001 Certified Company SALES OFFICE (301) TECHNICAL SUPPORT (301) USER MANUAL MODEL 1052 idsl Modem with RS-232 Interface An ISO-9001 Certified Company Part# 07M1052-B Doc# 058061UB Revised 5/24/02 SALES OFFICE (301) 975-1000 TECHNICAL SUPPORT (301) 975-1007 TABLE OF

More information

DVI ELR Extender over one CAT5

DVI ELR Extender over one CAT5 DVI ELR Extender over one CAT5 EXT-DVI-1CAT5-ELR User Manual Important Safety Instructions 1 Read these instructions 2 Keep these instructions 3 Heed all warnings 4 Follow all instructions 5 Do not use

More information

USER MANUAL MODEL 570/ Base-T (CAT-5) Surge Protectors SALES OFFICE (301) TECHNICAL SUPPORT (301)

USER MANUAL MODEL 570/ Base-T (CAT-5) Surge Protectors SALES OFFICE (301) TECHNICAL SUPPORT (301) USER MANUAL MODEL 570/580 100Base-T (CAT-5) Surge Protectors Part# 07M570/580-B Doc# 074091UB Revised 2/16/96 SALES OFFICE (301) 975-1000 TECHNICAL SUPPORT (301) 975-1007 1.0 WARRANTY INFORMATION Patton

More information

HCS-3600 / 3602 / 3604 Laboratory Grade & High RFI Immunity Switching Mode Power Supply with Rotary Encoder Control

HCS-3600 / 3602 / 3604 Laboratory Grade & High RFI Immunity Switching Mode Power Supply with Rotary Encoder Control HCS-3600 / 3602 / 3604 Laboratory Grade & High RFI Immunity Switching Mode Power Supply with Rotary Encoder Control 1. INTRODUCTION User Manual This family of efficient, upgraded SMPS with small form factor,

More information

EISB Series INSTALLATION GUIDE INTRODUCTION. A Line of Managed and Unmanaged Ethernet Switching Hubs

EISB Series INSTALLATION GUIDE INTRODUCTION. A Line of Managed and Unmanaged Ethernet Switching Hubs EISB Series A Line of Managed and Unmanaged Ethernet Switching Hubs INSTALLATION GUIDE INTRODUCTION The EISB Series of Ethernet switches give the user a choice between a simple, easy-to-install Plug and

More information

INSTRUCTION MANUAL CM-60. Monitor. Ultra Stereo Labs, Inc. 181 Bonetti Drive San Luis Obispo, CA Telephone

INSTRUCTION MANUAL CM-60. Monitor. Ultra Stereo Labs, Inc. 181 Bonetti Drive San Luis Obispo, CA Telephone CM-60 Monitor INSTRUCTION MANUAL Quality Cinema Products Ultra Stereo Labs, Inc. 181 Bonetti Drive San Luis Obispo, CA 93401 Telephone 805.549.0161 e-mail usl@uslinc.com One Year Limited Warranty Ultra

More information

Brocade ICX 6610 Switch

Brocade ICX 6610 Switch 6 May 2015 Brocade ICX 6610 Switch Technical Specifications 2015, Brocade Communications Systems, Inc. All Rights Reserved. ADX, Brocade, Brocade Assurance, the B-wing symbol, DCX, Fabric OS, HyperEdge,

More information

Innovative Circuit Technology Ltd.

Innovative Circuit Technology Ltd. Innovative Circuit Technology Ltd. Pro Series DC Power Supply INSTRUCTION MANUAL 855-343-001 Models: ICT690-12S/ICT690-12SB ICT690-24S/ICT690-24SB ICT690-48S/ICT690-48SB ICT1190-12S/ICT1190-12SB ICT1190-24S/ICT1190-24SB

More information

Dual Link DVI Extender

Dual Link DVI Extender 2x Dual Link DVI Extender EXT-2DVI-CATDL User Manual Release A4 2x Dual Link DVI Extender Important Safety Instructions 1. Read these instructions. 2. Keep these instructions. 3. Heed all warnings. 4.

More information

MX User Manual. Dual-View Video Processor. rev: Made in Taiwan

MX User Manual. Dual-View Video Processor. rev: Made in Taiwan MX-5022 Dual-View Video Processor User Manual rev: 151210 Made in Taiwan Safety and Notice The MX-5022 Dual-View Video Processor has been tested for conformance to safety regulations and requirements,

More information

LBC-PSW52. Link Bridge TM Presentation Scaling Switch with 5 Inputs and Two Mirrored Outputs

LBC-PSW52. Link Bridge TM Presentation Scaling Switch with 5 Inputs and Two Mirrored Outputs LBC-PSW52 Link Bridge TM Presentation Scaling Switch with 5 Inputs and Two Mirrored Outputs BCI reserves the right to make changes to the products described herein without prior notice or consent. No liability

More information

Operating Instruction Manual POWERED MIXER. Model MX-401. Toa Electric Co., Ltd. KOBE, JAPAN

Operating Instruction Manual POWERED MIXER. Model MX-401. Toa Electric Co., Ltd. KOBE, JAPAN Operating Instruction Manual POWERED MIXER Model MX-401 Toa Electric Co., Ltd. KOBE, JAPAN Contents General Description Features Front Panel [Names of components & their usage] Rear Panel [Names of components

More information

USB 2.0 Ranger High Speed Extender System. User Guide

USB 2.0 Ranger High Speed Extender System. User Guide USB 2.0 Ranger 2101 High Speed Extender System User Guide Powered by ExtremeUSB Thank you for purchasing the Ranger 2101. Please read this guide thoroughly. This document applies to Part Numbers: 00-00231

More information

TSD-DA28 2x8 Balanced Line Distribution Amplifier

TSD-DA28 2x8 Balanced Line Distribution Amplifier 2x8 Balanced Line Distribution Amplifier 1 Description The Atlas Sound 2x8 distribution amplifier is designed to provide clean, isolated signal distribution locally or to remote locations. The unit allows

More information

Aruba 3000 Multi-Service Mobility Controller Series. Installation Guide

Aruba 3000 Multi-Service Mobility Controller Series. Installation Guide Aruba 3000 Multi-Service Mobility Controller Series Installation Guide Copyright 2007 Aruba Wireless Networks, Inc. All rights reserved. Trademarks Aruba Networks is a registered trademark, and Mobility

More information

Plus-X 300. Installation and Operation Manual

Plus-X 300. Installation and Operation Manual Plus-X 300 Installation and Operation Manual Table of Contents Introduction... 1 Compatibility... 1 Installation... 1 Configuration... 2 Operation... 5 Getting Help... 6 Warranty... 6 Appendix A: Specifications...

More information

DVI ELR Extender over one CAT5

DVI ELR Extender over one CAT5 DVI ELR Extender over one CAT5 EXT-DVI-1CAT5-ELR User Manual Release A3 Important Safety Instructions 1. Read these instructions. 2. Keep these instructions. 3. Heed all warnings. 4. Follow all instructions.

More information

Vigil 3 Amplifiers. Installation Instructions

Vigil 3 Amplifiers. Installation Instructions Manual name: Vigil 3 Amplifier Installation Manual Issue: 1 ECR: N/A Date of issue: Dec 2016 Dec 2016 Baldwin Boxall Communications Limited Wealden Industrial Estate Farningham Road, Jarvis Brook Crowborough

More information

MX-5004MZ. User Manual. 4x1 HDMI 2.0a Quad-View Video Processor with 4K2K60 4:4:4. rev: Made in Taiwan

MX-5004MZ. User Manual. 4x1 HDMI 2.0a Quad-View Video Processor with 4K2K60 4:4:4. rev: Made in Taiwan MX-5004MZ 4x1 HDMI 2.0a Quad-View Video Processor with 4K2K60 4:4:4 User Manual rev: 160318 Made in Taiwan Safety and Notice The MX-5004MZ 4x1 HDMI 2.0a Quad-View Video Processor with 4K2K60 4:4:4 has

More information

MXA2080. Stereo Power Amplifier. Owner s Manual

MXA2080. Stereo Power Amplifier. Owner s Manual MXA2080 Stereo Power Amplifier Owner s Manual CONTENTS Introduction 2 Installation and Safety 2 Power Inlet 3 Smart My-Link Input/output 3 Line Input 3 Line Output 3 Loudspeaker Output 3 Remote Trigger

More information

EL5200 HDMI + USB 2.0 Extender HDMI and USB m Cat 5e KVM Extender System. User Guide

EL5200 HDMI + USB 2.0 Extender HDMI and USB m Cat 5e KVM Extender System. User Guide EL5200 HDMI + USB 2.0 Extender HDMI and USB 2.0 100m Cat 5e KVM Extender System User Guide Thank you for purchasing the EL5200 KVM Extender. Please read this guide thoroughly. FCC Radio Frequency Interference

More information

USB 2.0 Ranger Port USB m Cat 5e Extender System. User Guide

USB 2.0 Ranger Port USB m Cat 5e Extender System. User Guide USB 2.0 Ranger 2304 4-Port USB 2.0 100m Cat 5e Extender System User Guide Thank you for purchasing the USB 2.0 Ranger 2304. Please read this guide thoroughly. This document applies to Part Numbers: 00-00347,

More information

Remote Control for Inverter RC-200. Manual. Please read this manual before operating your RC-200 Remote Control

Remote Control for Inverter RC-200. Manual. Please read this manual before operating your RC-200 Remote Control Remote Control for Inverter RC-200 Owner's Manual Please read this manual before operating your RC-200 Remote Control Owner's Manual Index SECTION 1 Safety...3 SECTION 2 Description...3 SECTION 3 Layout

More information

Operating instruction Manual POWERED MIXER. Model MX-101. Toa Electric Co., Ltd. KOBE, JAPAN

Operating instruction Manual POWERED MIXER. Model MX-101. Toa Electric Co., Ltd. KOBE, JAPAN Operating instruction Manual POWERED MIXER Model MX-101 Toa Electric Co., Ltd. KOBE, JAPAN Contents Precautions... 1 General Description... 2 Features... 2 Front Panel (Names of components & their usage)...

More information

USB 3.0 Spectra Port USB m Multimode Fiber Extender System. User Guide

USB 3.0 Spectra Port USB m Multimode Fiber Extender System. User Guide USB 3.0 Spectra 3022 2-Port USB 3.0 100m Multimode Fiber Extender System User Guide Thank you for purchasing the USB 3.0 Spectra 3022. Please read this guide thoroughly. This document applies to Part Numbers:

More information

CTI 2551-A 8-CHANNEL ISOLATED THERMOCOUPLE INPUT MODULE INSTALLATION AND OPERATION GUIDE. Version 1.3 CTI Part # * *

CTI 2551-A 8-CHANNEL ISOLATED THERMOCOUPLE INPUT MODULE INSTALLATION AND OPERATION GUIDE. Version 1.3 CTI Part # * * CTI 2551-A 8-CHANNEL ISOLATED THERMOCOUPLE INPUT MODULE INSTALLATION AND OPERATION GUIDE Version 1.3 CTI Part #062-00305-013 *062-00305-011* 2551-AIOG 110106 $25 Copyright 2006 Control Technology Inc.

More information

USER MANUAL MODEL 515 DB-15 Surge Protector

USER MANUAL MODEL 515 DB-15 Surge Protector USER MANUAL MODEL 515 DB-15 Surge Protector Part# 07M515-A Doc# 074220U, Rev. B Revised 1/22/08 SALES OFFICE (301) 975-1000 TECHNICAL SUPPORT (301) 975-1007 http://www.patton.com 1.0 WARRANTY Patton Electronics

More information

TVA2.1 2-Channel Digital Amplifier Installation Manual

TVA2.1 2-Channel Digital Amplifier Installation Manual TVA2.1 2-Channel Digital Amplifier Installation Manual SAFETY INSTRUCTIONS WARNING: TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE THIS APPLIANCE TO RAIN OR MOISTURE. CAUTION: TO REDUCE THE

More information

User Manual rev: Made in Taiwan

User Manual rev: Made in Taiwan SP-1014 1x4 DVI Splitter over Single Cat.X with HDCP Support User Manual rev: 111209 Made in Taiwan The SP-1014 1x4 DVI Splitter over Single Cat.X with HDCP Support has been tested for conformance to safety

More information

USBTHERE User Guide USB204EXTFIB. Featuring ExtremeUSB Technology

USBTHERE User Guide USB204EXTFIB. Featuring ExtremeUSB Technology USBTHERE User Guide USB204EXTFIB Featuring ExtremeUSB Technology FCC Radio Frequency Interference Statement Warning The USBthere has been tested and found compliant with the limits for a Class A digital

More information

APT20. User Manual.

APT20. User Manual. APT20 User Manual www.audac.eu 2 Index Introduction 5 Precautions 6 Safety requirements 6 Caution servicing 6 EC Declaration of conformity 7 Waste of Electrical and Electronic Equipment (WEEE) 7 Caution

More information

Kramer Electronics, Ltd.

Kramer Electronics, Ltd. Kramer Electronics, Ltd. Preliminary USER MANUAL Model: 903 Personal Stereo Amplifier Contents Contents 1 Introduction 1 2 Getting Started 1 2.1 Quick Start 2 3 Overview 3 4 Your 903 Personal Stereo Amplifier

More information

DVI KVM. Extra Long Range Extender Over One CAT5. User Manual EXT-DVIKVM-ELR. Release A8

DVI KVM. Extra Long Range Extender Over One CAT5. User Manual EXT-DVIKVM-ELR. Release A8 DVI KVM Extra Long Range Extender Over One CAT5 EXT-DVIKVM-ELR User Manual Release A8 Important Safety Instructions 1 Read these instructions 2 Keep these instructions 3 Heed all warnings 4 Follow all

More information

POWER SERIES Plus Watt-VAR / Watt-Power Factor Digital Switchboard Meter User s Manual IM2492WVPF-1

POWER SERIES Plus Watt-VAR / Watt-Power Factor Digital Switchboard Meter User s Manual IM2492WVPF-1 POWER SERIES Plus Watt-VAR / Watt-Power Factor Digital Switchboard Meter User s Manual General Description The POWER SERIES Plus digital switchboard meters incorporate the latest DSP microprocessor technology.

More information

Audio. one CAT-5 EXT-DVI-1CAT5-SR. User Manual. Release A2

Audio. one CAT-5 EXT-DVI-1CAT5-SR. User Manual. Release A2 Audio DVI 3GSDI ELR Lite Embedder Extender over one CAT-5 EXT-DVI-1CAT5-SR User Manual Release A2 DVI ELR Lite Extender over one CAT-5 Important Safety Instructions 1. Read these instructions. 2. Keep

More information

WR-5e Remote Control

WR-5e Remote Control 1. Introduction WR-5e Remote Control The WR-5e is a microprocessor based serial data remote control unit for Ashly NE or NX products. Compatible products currently include Pema amplifiers, ne8800 and ne4800

More information

F2238A and F2245A Fiber-Optic EIA-530/MIL-STD Modem Technical Manual

F2238A and F2245A Fiber-Optic EIA-530/MIL-STD Modem Technical Manual F2238A and F2245A Fiber-Optic EIA-530/MIL-STD-188-114 Modem Technical Manual Revision C October 2013 VERSITRON, Inc. 83 Albe Drive / Suite C Newark, DE 19702 www.versitron.com PROPRIETARY DATA All data

More information

TETRIS 2500 High Impedance Active Probe. Instruction Manual

TETRIS 2500 High Impedance Active Probe. Instruction Manual TETRIS 2500 High Impedance Active Probe Instruction Manual Copyright 2018 PMK GmbH All rights reserved. Information in this publication supersedes that in all previously published material. Specifications

More information

PDS8u POWER DISTRIBUTION SYSTEM USER'S MANUAL

PDS8u POWER DISTRIBUTION SYSTEM USER'S MANUAL PDS8u POWER DISTRIBUTION SYSTEM USER'S MANUAL 1 IMPORTANT SAFETY INSTRUCTION READ FIRST This symbol, whenever it appears, alerts you to the presence of uninsulated dangerous voltage inside the enclosure-voltage

More information

USER MANUAL. DV-HAS HDMI Audio Separator LIT Bergen Boulevard, Woodland Park, NJ Tel FAX Web:

USER MANUAL. DV-HAS HDMI Audio Separator LIT Bergen Boulevard, Woodland Park, NJ Tel FAX Web: USER MANUAL DV-HAS HDMI Audio Separator 244 Bergen Boulevard, Woodland Park, NJ 07424 Tel 973-785-4347 FAX 973-785-3318 Web: www.fsrinc.com LIT1460 Proprietary Information All information in this manual

More information

Installation Manual for D1800 Series High Power PoE Midspan Power Supply

Installation Manual for D1800 Series High Power PoE Midspan Power Supply Installation Manual for D1800 Series High Power PoE Midspan Power Supply Dycon Power Solutions Ltd Tel: +44 (0)1443 471 900 Unit A - Cwm Cynon Business Park Mountain Ash CF45 4ER - UK www.dyconpower.com

More information

Line Impedance Stabilization Network (LISN)

Line Impedance Stabilization Network (LISN) Model 3816/2 Line Impedance Stabilization Network (LISN) User Manual ETS-Lindgren Inc. reserves the right to make changes to any product described herein in order to improve function, design, or for any

More information

MODEL 805 USER MANUAL

MODEL 805 USER MANUAL MODEL 805 USER MANUAL All Rights Reserved Page 1 of 12 UNPACKING & INSPECTION Save all packing materials they are required for returns and warranty service. Inspect the 805 and packing materials for any

More information

Owner s Manual. TSD-RL21 2x1 Mic/Line Mixer. TSD-RL21 2x1 Mic/Line Mixer with Remote Level

Owner s Manual. TSD-RL21 2x1 Mic/Line Mixer. TSD-RL21 2x1 Mic/Line Mixer with Remote Level Owner s Manual with Remote Level Owner s Manual Description The versatile Atlas Sound 2x1 mic/line mixer is ideal for applications where paging, public address, and BGM music is required. Use as a standalone

More information

Matrix for HDMI 1.3 EXT-HDMI User Manual. Release A6

Matrix for HDMI 1.3 EXT-HDMI User Manual. Release A6 Matrix for HDMI 1.3 EXT-HDMI1.3-444 User Manual Release A6 4x4 Matrix for HDMI 1.3 Important Safety Instructions 1. Read these instructions. 2. Keep these instructions. 3. Heed all warnings. 4. Follow

More information

Rhino Redundancy Module PSM24-REM360S. Operating Instructions

Rhino Redundancy Module PSM24-REM360S. Operating Instructions Rhino Redundancy Module PSM4-REM360S Operating Instructions RHINO REDUNDANCY MODULE PSM4-REM360S Description With this module and two power supplies of the PSM series (78, 90, 56, 80 and 360 watt models),

More information

SP-1009D. 1x9 Dual Link DVI Distribution Amplifier. User Manual. Made in Taiwan

SP-1009D. 1x9 Dual Link DVI Distribution Amplifier. User Manual. Made in Taiwan SP-1009D 1x9 Dual Link DVI Distribution Amplifier User Manual Made in Taiwan Safety and Notice The SP-1009D 1x9 Dual Link DVI Distribution Amplifier has been tested for conformance to safety regulations

More information

USB 3.0 Spectra

USB 3.0 Spectra USB 3.0 Spectra 3001-15 1-Port USB 3.0 15m Active Extension Cable User Guide Thank you for purchasing the Icron USB 3.0 Spectra 3001-15. Please read this guide thoroughly. This document applies to Part

More information

MA V 30W Mixer Amplifier Order code: CRAM02 MA V 60W Mixer Amplifier Order code: CRAM03 USER MANUAL

MA V 30W Mixer Amplifier Order code: CRAM02 MA V 60W Mixer Amplifier Order code: CRAM03 USER MANUAL www.cleveracoustics.co.uk MA 130 100V 30W Mixer Amplifier Order code: CRAM02 MA 160 100V 60W Mixer Amplifier Order code: CRAM03 USER MANUAL WARNING FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL CAREFULLY

More information

DCS-E 1kW Series, DLM-E 3kW & 4kW Power Supplies

DCS-E 1kW Series, DLM-E 3kW & 4kW Power Supplies DCS-E 1kW Series, DLM-E 3kW & 4kW Power Supplies M51A Option: Isolated Analog Programming Manual Power Supplies Elgar Electronics Corporation 9250 Brown Deer Road San Diego, CA 92121-2294 1-800-73ELGAR

More information

EASON TECHNOLOGY. IO8 & IO24 Break-Out Module

EASON TECHNOLOGY. IO8 & IO24 Break-Out Module EASON TECHNOLOGY IO8 & IO24 Break-Out Module p/n 50-00180-01 Revision1.2 Eason Technology, Inc. 7975 Cameron Dr. Bldg 300 Windsor, CA 95492 Phone (707) 837-0120 FAX (707) 837-2742 http://www.eason.com

More information

1x2 HDMI Splitter over Cat.X with HDBaseT-Lite, 4K2K, IR & RS-232

1x2 HDMI Splitter over Cat.X with HDBaseT-Lite, 4K2K, IR & RS-232 SP-5012V 1x2 HDMI Splitter over Cat.X with HDBaseT-Lite, 4K2K, IR & RS-232 User Manual rev: 140806 Made in Taiwan Safety and Notice The SP-5012V 1x2 HDMI Splitter over Cat.X with HDBaseT-Lite, 4K2K, IR

More information

INSTRUCTION MANUAL. Instruction Manual. Analog Multi-Tube Vortexer Digital Multi-Tube Vortexer

INSTRUCTION MANUAL. Instruction Manual. Analog Multi-Tube Vortexer Digital Multi-Tube Vortexer INSTRUCTION MANUAL Instruction Manual Analog Multi-Tube Vortexer Digital Multi-Tube Vortexer Table of Contents Package Contents............ 1 Warranty............ 1 Installation............ 2 Maintenance

More information

RT4B-110V/12A RECTIFIER

RT4B-110V/12A RECTIFIER The RT4B-110V/12A is a switched mode rectifier (SMR) module designed to provide up to 12A of output current into a 110V nominal system. It can be used with or without a cooling fan. With a fan it runs

More information

VIP-804 QUAD ENHANCED NETWORK AUDIO PORT

VIP-804 QUAD ENHANCED NETWORK AUDIO PORT ISSUE 6 VIP-804 QUAD ENHANCED NETWORK AUDIO PORT INTRODUCTION The VIP-804 Quad Enhanced Network Audio Port enables voice access to four zones of one-way paging over an IP network, allowing page zones to

More information

Back-UPS RS 550 Installation & Operation

Back-UPS RS 550 Installation & Operation Back-UPS RS 550 Installation & Operation Inventory Safety Do not install the UPS in direct sunlight, in excessive heat, humidity, or in contact with fluids. bu001a Do not connect a laser printer or hair

More information

Series 8000 RF Signal Switch Solution

Series 8000 RF Signal Switch Solution RF Signal Switch Solution Operation Manual Operation Manual, Part Number 07508000 006, Rev. B, Oct 7, 2014 All technical data and specifications in this publication are subject to change without prior

More information

Back-UPS RS APC Back-UPS RS 800VA 120V Black

Back-UPS RS APC Back-UPS RS 800VA 120V Black Back-UPS RS APC Back-UPS RS 800VA 120V Black APC Back-UPS RS, 540 Watts / 800 VA,Input 120V / Output 120V Includes: CD with software, Cord management straps, Free trial of anti-virus : firewall : email

More information

Installation, Testing, and Operating Procedures 30 AMP PORTABLE AND PERMANENT SERIES GFCI SINGLE and MULTIPHASE

Installation, Testing, and Operating Procedures 30 AMP PORTABLE AND PERMANENT SERIES GFCI SINGLE and MULTIPHASE IMPORTANT! Please read all the information on this sheet. SAVE THESE INSTRUCTIONS! NOTICE BEFORE USING READ INSTRUCTIONS COMPLETELY. TO BE INSTALLED BY A QUALIFIED ELECTRICIAN IN ACCORDANCE WITH NATIONAL

More information

Note: Unit is set at the factory for 120V operation. Be sure to change the fuse. (2A rating) before switching to 230V operation.

Note: Unit is set at the factory for 120V operation. Be sure to change the fuse. (2A rating) before switching to 230V operation. Note: Unit is set at the factory for 120V operation. Be sure to change the fuse (2A rating) before switching to 230V operation. (2) FCC Statement 1. This device complies with Part 15 of the FCC Rules.

More information

G3B/G3BD. Model Number Structure. Ordering Information. Solid State Relays Model Number Legend. List of Models

G3B/G3BD. Model Number Structure. Ordering Information. Solid State Relays Model Number Legend. List of Models Solid State Relays G3@-VD CSM_G3B_G3BD_DS_E_5_1 International Standards for G3B Series, Same Profile as MK Power Relays Shape-compatible with mechanical relays. Certified by UL, CSA, and VDE (models numbers

More information

Precise Fiber Couple Laser Light Source

Precise Fiber Couple Laser Light Source Precise Fiber Couple Laser Light Source User Guide User Guide Document No. AEO-LD1480-0001 1. SAFTEY REQUIREMENT... 2 Precise Laser Light Source Page 1 / 15 1.1 User esponsibility...3 2. Description..

More information

EI Series INSTALLATION GUIDE INTRODUCTION. A Line of Fixed-Port Industrial Ethernet Hubs

EI Series INSTALLATION GUIDE INTRODUCTION. A Line of Fixed-Port Industrial Ethernet Hubs EI Series A Line of Fixed-Port Industrial Ethernet Hubs INTRODUCTION INSTALLATION GUIDE The EI series of Industrial Ethernet hubs allow for the expansion of shared 10 Mbps Ethernet networks on the plant

More information

OPERATOR MANUAL OSD461A/OSD463A AUDIO FIBER OPTIC TRANSMISSION SYSTEM

OPERATOR MANUAL OSD461A/OSD463A AUDIO FIBER OPTIC TRANSMISSION SYSTEM OPERATOR MANUAL OSD461A/OSD463A AUDIO FIBER OPTIC TRANSMISSION SYSTEM OSD461A/OSD463A AUDIO FIBER OPTIC TRANSMISSION SYSTEM Document No. 101052 Rev. 01 PAGE 2 INDEX 1 1 TECHNICAL SUMMARY... 4 1.1 BRIEF

More information

User Guide. Model No.: GDI-CTDK201/203/208

User Guide. Model No.: GDI-CTDK201/203/208 User Guide Model No.: GDI-CTDK201/203/208 2 Important Safety Instructions and Warnings Please read before installation WARNING: CAUTION: To reduce the risk of fire or electrical shock, do not expose the

More information

CAT5 Extender User Manual

CAT5 Extender User Manual CAT5 Extender User Manual P73228 F1D084 Introduction Thank you for purchasing the Belkin Components CAT5 KVM Extender! The CAT5 KVM Extender allows users to control their computer or KVM switch from up

More information

UHDN 4P Duo. User Manual. 4-Port Dual Head Ultra 4K-60Hz HDMI KVM Switch with USB 2.0 and Audio Support. Manage 4 computers from a single workstation

UHDN 4P Duo. User Manual. 4-Port Dual Head Ultra 4K-60Hz HDMI KVM Switch with USB 2.0 and Audio Support. Manage 4 computers from a single workstation UHDN 4P Duo User Manual 4-Port Dual Head Ultra 4K-60Hz HDMI KVM Switch with USB 2.0 and Audio Support Manage 4 computers from a single workstation Made in U.S.A. www.smartavi.com 1 1-800-AVI-2131 TABLE

More information