Metering Devices, Protective Relays, Software and Connectivity. Pre-Wired Control Power, Voltage and CT Inputs
|
|
- Claud Thompson
- 6 years ago
- Views:
Transcription
1 .3 Features and Benefits Saves installation time and cost One part number to order; no need to worry that any part has been left out Pick the meter or meters you need as it is designed to fit various Eaton power and energy meters, at varying price points Factory Wired Most electrical contractors are very familiar with wiring meters. However, it does take time to place the disconnect, CT shorting blocks, terminal blocks, control power transformer, etc. and associated wiring. It is not uncommon for errors to be introduced during the installation of multiple meters; it's just inherent in wiring. With Eaton s Enclosed Meter line, everything is wired at the factory: the shorting block, terminal blocks, etc., assuring that it s done right. Further, to ensure safety, Eaton s Enclosed Meter line includes a primary fusible disconnect for line voltage that can be turned off during meter maintenance. For applications with line voltages above the rated power supply of the meter, an optional control power transformer is supplied in the enclosure. Control voltage can also be supplied via a separate source that is wired to the field installation terminal block. CT inputs for the meter are wired directly to shorting terminal blocks for easy field installation. Factory wired products also save on installation time and costs. The meters are flush mounted on the enclosure door with all inputs/outputs factory-wired to terminal blocks. NEMA Rated NEMA 12 enclosure prevents dust and other materials from entering. Internal gaskets also prevent air irritants from harming the vital equipment inside. This quality enclosure meets most indoor application needs. NEMA 3R enclosure is constructed for either indoor or outdoor use to provide a degree of protection to personnel against access to hazardous parts; to provide a degree of protection of the equipment inside the enclosure against ingress of solid foreign objects (falling dirt); to provide a degree of protection with respect to harmful effects on the equipment due to the ingress of water (rain, sleet, snow); and that will be undamaged by the external formation of ice on the enclosure. NEMA 4X enclosure provides the same degree of protection as the NEMA 3R with the additional protection against windblown dust, splashing and hose directed water, and protection against corrosion. NEMA 12, Door Open Pre-Wired Control Power, Voltage and CT Inputs NEMA 12 Multi Unit Open and Folded Out Control power, voltage, CT and communications inputs Pre-Wired Fusible Disconnect Pre-Wired Neutral, Ground and Input/Output Terminal Blocks Pre-Wired Current Transformer Shorting Terminal Block Gateway Power Supply Fused Disconnect Meter Fusing PX Gateway Fused Control Power Transformer Ground CT Shorting Blocks Volume 3 Power Distribution and Control Assemblies CA E June V3-T-131
2 .3, Protective Relays, Software and Connectivity NEMA 3R Single Unit Closed and Open NEMA 4X Single Unit Closed and Open Catalog Number Selection Single Unit Enclosed Meter Multi Unit Enclosed Meter Note 1 Not available with IQ 35M. PXM2250MA B Meter Type PXM2250MA65105 PXM2250MA65115 PXM2250MA65145 PXM2260MA65105 PXM2260MA65115 PXM2260MA65145 PXM2270MA65105 PXM2270MA65115 PXM2270MA65145 IQ250MA65100 IQ250MA65110 IQ250MA65114 IQ260MA65100 IQ260MA65110 IQ260MA65114 IQ150MA6511 IQ150MA6512 Meter Type IQ35MA12 IQ150MA6511 IQ250MA65100 IQ260MA65100 NEMA Rating 2 = NEMA 12 3 = NEMA 3R 4 = NEMA 4X CPT Option A = 120/240 Vac (no CPT) B = 480 Vac (CPT) IQ150MA6511-2B 4 C NEMA Rating 2 = NEMA = NEMA 3R 4 = NEMA 4X CPT Option A =No CPT B =CPT 1 Number of Meters 4 = 4 meters Communications C = Includes PXG200E V3-T-132 Volume 3 Power Distribution and Control Assemblies CA E June
3 .3 Technical Data and Specifications Enclosed Meters Description Specification Enclosure rating NEMA 12, 3R, 4X Enclosure operating temperature Dimensions Meters Communications (multi unit only) 20 C to +40 C Note: Temperature range of meter is 20 C to 70 C. If applied outside, proper precautions should be taken to avoid exceeding the maximum and minimum temperature ratings of the meter. Single unit: NEMA 12 (8.00" wide x 16.30" high x 10.40" deep), NEMA 3R/4X (8.00" wide x 16.30" high x.60" deep) Multi unit: NEMA 12 (13.00" wide x 30.00" high x 15.20" deep) NEMA 3R (13.20" wide x 30.10" high x 14.60" deep) NEMA 4X (13.00" wide x 30.00" high x 14.00" deep) Single unit: IQ 150, IQ 250/260 and PXM 2000 models Multi unit: IQ 35M, IQ 150 and IQ 250/260 Power Xpert Gateway 200E Control voltage Up to 265V (IQ 35M/150/250/260 and PXM 2000), no CPT required Greater than 265V (IQ 150/250/260 and PXM 2000) CPT required Separate source control no CPT required Basic model Fusible disconnect primary voltage 6 point shorting block Ground terminal block Neutral terminal block 8 point terminal block for input/output modules for IQ 250/260 and PXM 2000 Wiring Wired for three-phase four-wire applications. Three-phase three-wire applications will need to change the wiring for both the voltage and current per the wiring diagram in the meter instruction manual. Certifications UL 508A and cul Source control No separate source control voltage required for applications below 265 Vac (IQ 35M/150/250/260 and PXM 2000) Rating 600V rated power voltage terminal block and wiring Pre-wire Pre-wired current transformer, shorting terminal block(s), neutral, ground, voltage, control power, fusible disconnect and input/output terminal block(s) Latch Optional features Padlocking latch provision Control power transformer single unit 50 VA, multi unit 200 VA control power supply for meter where monitored voltage is above 265 Vac (IQ 150/250/260 and PXM 2000) Note: Specifications are subject to change without notice and represent the maximum capabilities of the product with all options installed. This is not a complete feature list. Features and functionality may vary depending on selected options, firmware version and product model. Please refer to the technical data sheet and User Manual for detailed specifications. Volume 3 Power Distribution and Control Assemblies CA E June V3-T-133
4 .3, Protective Relays, Software and Connectivity Dimensions Approximate Dimensions in Inches (mm) NEMA 12 Single Unit Enclosure 10.3 (263.).60 (243.8) Top View 8.00 (203.2) 5.00 (127.0) (414.0) 14. (380.7) Right Side View Left Side View Rear View NEMA 12 Multi Unit Enclosure (330.2) 15.1 (385.8) (357.4) Top View 6.7 (177.0) Typ (385.8) ø (22.1) (762.0) (723.) Right Side View Rear View V3-T-134 Volume 3 Power Distribution and Control Assemblies CA E June
5 .3 Approximate Dimensions in Inches (mm) NEMA 3R/4X Single Unit Enclosure Top View This Drip Cap is on NEMA 3R Only.58 (243.3) 5.00 (127.0) (414.0) 14. (380.7) Right Side View Rear View NEMA 3R/4X Multi Unit Enclosure (335.3) (330.2) This Drip Cap is on NEMA 3R Only (371.) (356.4) Top View ø0.34 ø (266.7) (22.1) (763.8) (762.0) (685.8) (723.) Right Side View (no door) Rear View Volume 3 Power Distribution and Control Assemblies CA E June V3-T-135
6 .4, Protective Relays, Software and Connectivity Protective Relays Product Selection Guide Protective Relay Selection Chart Functions Contents Notes 1 The 50 and 51 protective functions can be controlled for reverse, forward or both directional protection. 2 The 50N, 51N, 50G and 51G protective functions can be controlled for reverse, forward or both directional protection. Description Product Selection Guide FP FP FP MP MP MD-3000 /Generator Differential Relay.... Digitrip VR-300 Multifunctional Voltage Relay DP-300 Current Differential Relay..... EDR ETR-4000 Transformer Relay Ground Fault Relay Universal RTD Module IQ 125 Volt DC Power Supply Page V3-T-140 V3-T-150 V3-T-158 V3-T-166 V3-T-176 V3-T-182 V3-T-185 V3-T-15 V3-T-1 V3-T-204 V3-T-215 V3-T-228 V3-T-232 V3-T-236 Section Page Number Number V3-T-185 V3-T-204 V3-T-158 V3-T-150 V3-T-140 V3-T-166 V3-T-176 V3-T-182 V3-T-15 V3-T-1 V3-T-215 Phase inst. OC 50 Phase TOC 51 Ground inst. OC (measured) 50G Ground TOC (measured) 51G Phase directional control 1 67 Ground directional control 2 67N Phase voltage restrained OC 51VR No. of curves (ANSI/IEC/thermal) Zone interlocking Thermal overload 4 Locked rotor 4S/51 Jam/stall 51R Undervoltage 27 Current unbalance 46 Negative sequence voltage 47 Power factor 55 Overvoltage 5 Frequency (over/under) 81 Forward/reverse VARs 32V V3-T-136 Volume 3 Power Distribution and Control Assemblies CA E June
7 Protective Relays.4 Functions, continued Section Page Number Number V3-T-185 V3-T-204 V3-T-158 V3-T-150 V3-T-140 V3-T-166 V3-T-176 V3-T-182 V3-T-15 V3-T-1 V3-T-215 Differential Forward/reverse power 32 Sync check 25 Reclosing 7 Loss of potential block LOP Cold load pickup Breaker failure 50BF 2 nd harmonic restrain 5 th harmonic restrain 4 th harmonic restrain 87 GD ground differential Control Functions Section Page Number Number V3-T-185 V3-T-204 V3-T-158 V3-T-150 V3-T-140 V3-T-166 V3-T-176 V3-T-182 V3-T-15 V3-T-1 V3-T-215 Remote open/close (Trip only) Programmable I/O Programmable logic control Multiple settings groups Number of starts limit Starts per hour Time between starts Emergency override Reduced voltage starting Trip lock out Notes 1 87B using zone selective interlocking. 2 87M or 87G (motor or generator differential). 3 87M, 87T or 87G (motor, transformer or generator differential). 4 87T (transformer differential). Volume 3 Power Distribution and Control Assemblies CA E June V3-T-137
8 .4, Protective Relays, Software and Connectivity Protective Relays Metering Functions Section Page Number Number V3-T-185 V3-T-204 V3-T-158 V3-T-150 V3-T-140 V3-T-166 V3-T-176 V3-T-182 V3-T-15 V3-T-1 V3-T-215 Amperes 1 Ampere demand Volts Phase angle (current and voltage) Current only Positive, negative and zero sequence Watts Watt Demand Watthour VARs VAR demand VAR-hour VA VA Demand VA-hour Frequency Trending (load profile) Minimum/maximum recording Max. only Monitoring Functions Section Page Number Number V3-T-185 V3-T-204 V3-T-158 V3-T-150 V3-T-140 V3-T-166 V3-T-176 V3-T-182 V3-T-15 V3-T-1 V3-T-215 Trip circuit monitor Breaker wear Failure to close Oscillography Sequence of events Trip target data Clock Number of starts Acceleration time RTD temperature Hottest RTD Note 1 Differential and restrain current only. V3-T-138 Volume 3 Power Distribution and Control Assemblies CA E June
9 Protective Relays.4 Communications Section Page Number Number V3-T-185 V3-T-204 V3-T-158 V3-T-150 V3-T-140 V3-T-182 V3-T-176 V3-T-182 V3-T-15 V3-T-1 V3-T-215 Local human machine interface Remote communication port RS-232 RS-485 Ethernet copper Frequency shift key Optional Addressable Protocols INCOM Modbus-RTU Modbus-TCP Construction Section Page Number Number V3-T-185 V3-T-204 V3-T-158 V3-T-150 V3-T-140 V3-T-166 V3-T-176 V3-T-182 V3-T-15 V3-T-1 V3-T-215 Panel mount case Drawout Optional Removable terminals Operating temperature range Power supply options Vac Optional Optional Optional Optional Optional Removable terminals C C C C C C C C C C C Vdc Vdc Vac Vac/Vdc Vac/Vdc Vac/Vdc Vac/Vdc Vac/Vdc Vac/Vdc AC current inputs AC voltage inputs Wye PTs Delta/open delta PTs Binary inputs Alarm outputs 2 Form C 1 Form C 2 Form C 2 Form C 2 Form C 3 2 Form C 1 Form C 1 NO 1 Form C Trip outputs Analog outputs Local display LEDs (local targets) Standards Section Page Number Number V3-T-185 V3-T-204 V3-T-158 V3-T-150 V3-T-140 V3-T-166 V3-T-176 V3-T-182 V3-T-15 V3-T-1 V3-T Vac Vac Vac Vdc Vac Vdc Vac Vdc ANSI IEC UL CE DT-3030 only CSA Vdc Vac Volume 3 Power Distribution and Control Assemblies CA E June V3-T-13
SECTION SWITCHBOARDS
SECTION 26 24 13 PART 1 - GENERAL 1.1 SUMMARY A. Work Included: 1. Switchboards 2. Commercial Metering Switchboards 3. Non-Utility Power Meters (Microprocessor-Based Metering Equipment) PART 2 - PRODUCTS
More informationStandards. Electromechanical Safety Switches. Industrial Safety Products 179
Standards IEC 60947-1 explains the general rules relating to Low voltage switchgear and controlgear. The purpose of this standard is to harmonize as much as possible the product performance and test requirements
More informationEDR-3000 Eaton Distribution Relay
EDR-3000 Eaton Distribution Relay Technical Data New Information Description Page 1. General Description.......................... 2 2. Applications............................... 2 3. Drilling Pattern.............................
More informationGE Power Management. MMII Intelligent MCC Controller
A concept that will offer reduced overall installed cost and production efficiency through information availability to operators and maintenance. Presentation Overview 6 Applications 6 Protection and Control
More informationSolar Combiner Enclosure
Installation Instructions Solar Combiner Enclosure Catalog Numbers 1000-SB006, 1000-SB012 Topic Page Description 1 Important Safety Instructions 3 Nameplate Data 4 Planning for Installation 4 Install the
More informationMulti Unit Enclosed Meter
Contents Description Page Introduction Preliminary comments and safety precautions............................... 2 Warranty and liability information................ 2 Safety precautions..............................
More informationFP-5000 Feeder Protection
Effective: April 2001 Page 1 New Information FP-00 Feeder Protection Contents Description Page FP-00 Description......... 2 Application Description...... 2 Features, Functions and Benefits..............
More informationJK Series POWER DISTRIBUTION. Solid State Starters Medium Voltage A
POWER DISTRIBUTION JK Series Solid State Starters Medium Voltage 200-400-600-720A SOLID STATE STARTER JKSSS4+ Series The JKSSS Series of motor starter is the result of extensive research and development.
More informationFP-5000 Series Multi-functional Microprocessor-based Feeder Protective Relay
FP-5000 Series Multi-functional Microprocessor-based Feeder Protective Relay The power of fusion. 1874 1886 1893 1899 1906 1908 1911 1934 1962 1963 1976 1983 1990 1999 There s a certain energy at Eaton.
More informationMaximize process uptime with the SEL-patented motor thermal model.
SEL-710 Motor Protection Relay Maximize process uptime with the SEL-patented motor thermal model. Optimize motor performance with separate thermal models for the stator and rotor. Monitor stator and ambient
More informationEDR-3000 Eaton Distribution Relay
Supersedes November 2014 Contents Description Page General Description.... 2 Applications.... 3 Dimensions.... 5 Wiring Diagram.... 6 Specifications... 7 Ordering Information....11 Applications Provides
More informationSACE Emax 2 Specification guide
SACE Emax 2 Specification guide Specification Number: 26 01 20.17 Product Name: LOW VOLTAGE POWER CIRCUIT BREAKERS PART 1 GENERAL NOTE: ( ) Indicates option or a selection is to be made for quantity or
More informationMay Delivers real-time, Web-enabled monitoring of electrical distribution and control equipment
Power Xpert Gateway 200E Power Xpert Gateway Screenshots Delivers real-time, Web-enabled monitoring of electrical distribution and control equipment Product snapshot The Power Xpert Gateway 200E (PXG 200E)
More informationMetering Devices IQ 300
Effective: May 2001 Page 1 New Information Contents Description Page General Description......... 2 Specifications.............. 3 Field Wiring Connections.... 4 Page 2 Effective: May 2001 Applications
More informationMaximum Reliability & Excellent Value. Features. UL Listed Withstand & Close-On Ratings. Series 300 Power Transfer Switches
Series 300 Power Transfer Switches Maximum Reliability & Excellent Value With a Series 300 Transfer Switch, you get a product backed by ASCO Power Technologies, the industry leader responsible for virtually
More informationIQ Products. 10 IQ Products
Power Management Products IQ Products Product....................................... Product History.......................................... Product History Time Line..................................
More informationSECTION ( ) LIGHTING CONTROL PANELBOARD
(26 24 16.02) LIGHTING CONTROL PANELBOARD PART 1 GENERAL 1.01 SCOPE A. The Contractor shall furnish and install Lighting Control Panelboards as specified and as shown on the contract drawings. B. The Lighting
More information5.1. Motor Protection and Monitoring. Contents. Product Overview. Monitoring Relays. D64R Series Digital Ground Fault Relays...
.1 Ground Fault Relays and Monitors Contents Description Current.................. Phase................... Voltage.................. Ground Fault Relays and Monitors D64R Series Digital Ground Fault Relays....
More informationIPS INTELLIGENT PUMP STARTER
IPS INTELLIGENT PUMP STARTER The IPS Intelligent Pump Starter features SMARTSTART motor protection, integrated electronic pump protection overload, and power metering and data logging options. Ø & Ø, 0/60
More informationThe City of Winnipeg Dry Type Transformers up to 600 V Primary Section Bid Opportunity No Page 1 of 2
The City of Winnipeg Dry Type Transformers up to 600 V Primary Section 26121601 Bid Opportunity No. 1196-2014 Page 1 of 2 Part 1 General 1.1 RELATED REQUIREMENTS.1 Section 26 05 01 - Common Work Results
More informationSR489 SR489. Generator Management Relay. Economical protection, metering, and monitoring functions for small and medium sized generators.
SR489 Generator Management Relay Economical protection, metering, and monitoring functions for small and medium sized generators. 1 Product Highlights Inputs / Outputs Generator Protection Power Metering
More information9.3. Metering Devices, Protective Relays, Software and Connectivity
.3, Protective Relays, Software and Connectivity Product Eaton s IQ Multipoint Energy Submeter II is a revenue class electronic submetering device that can be mounted in panelboards or switchboards. When
More information4.3. Switchboards. Contents Description Pow-R-Line Drawout Molded Case Circuit Breaker Switchboards Product Selection...
.3 Product Description Drawout molded case circuit breaker switchboard Front accessible Front connected Through-the-door design drawout mechanism through 600A Insulated case UL 89 breakers up to 200A Visual
More informationBT300 HVAC Drives Electronic Bypass (E-Bypass) Options
BT300 HVAC Drives Electronic Bypass (E-Bypass) Options Description The BT300 Electronic Bypass (E-Bypass) Options are companion packages for the family of BT300 Variable Frequency Drives (VFDs). For information
More information.2 Section General Commissioning (Cx) Requirements. .3 Section Common Work Requirements - Electrical
Issued for Review Section 26 28 16.01 Air Circuit Breakers Page 1 of 7 PART 1 GENERAL 1.1 GENERAL.1 This specification serves to define requirements for a replacement of low voltage circuit breaker of
More informationJockey Pump Controllers
BR081001EN Microprocessor Based with Color Touchscreen Product Description ACROSS THE LINE Controllers operate across-the-line. Full voltage is applied to the motor for starting by the use of a single
More informationJockey Pump Controllers
BR081001EN Microprocessor Based with Color Touchscreen Product Description ACROSS THE LINE Controllers operate across-the-line. Full voltage is applied to the motor for starting by the use of a single
More informationwww. ElectricalPartManuals. com MICROSHIELD O/Cä Multiphase Time-Overcurrent Relay Highlights
August 2000 Highlights ANSI and IEC Time Overcurrent Curves RMS Response Programmable Input and Output Contacts Optional Four Shot Recloser Small Size and Available Bezel Kits Easily Retrofit Electromechanical
More informationSTANDARD SUBMITTAL PACKAGE
STANDARD SUBMITTAL PACKAGE SBP1000-51( ) FTA1000 Full Voltage Starting Electric Fire Pump Controllers Product Description Description Firetrol FTA1000 Full Voltage Fire Pump Controllers are intended for
More informationMICROSHIELD O/Cä Multiphase Time-Overcurrent Relay
ABB Automation Inc. Descriptive Bulletin Substation Automation and Protection Division 41-126M Coral Springs, FL Allentown, PA August 2000 MICROSHIELD O/Cä Multiphase Time-Overcurrent Relay Device Number:
More informationPower Meter PowerMonitor 500
ROCKWELL AUTOMATION PROCUREMENT SPECIFICATION PROCUREMENT SPECIFICATION PowerMonitor 500 NOTICE: The specification guidelines in this document are intended to aid in the specification of products. Specific
More informationFunction permission: yes/no. Operating range: 0.10 to 30 xin (step 0.01) Operating time: 0.02 to 300 s (step 0.01 s) Activation level 100%
Operating range: 0.10 to 30 xin (step 0.01) 50P(2) Activation level 100% Deactivation level 95% Timer accuracy: 30 ms Operating range: 0.10 to 30 xin (step 0.01) 50N/G(2) Activation level 100% Deactivation
More informationPowered to Perform. Everyday Reliability. Exceptional Value. Expertise and Support
A decentralized solution. Many drive applications utilize control panels with complex wiring taking up large amounts of space. These control panels are often mounted away from the application requiring
More informationPowerFlex 400 AC Drive Guide Specification
PowerFlex 400 AC Drive Guide Specification Adjustable Frequency Drives with Bypass 3.0 50HP @ 208V AC 3.0 350HP @ 480V AC PART 1 GENERAL 1.01 Quality Assurance A. The manufacturer shall have minimum 5
More informationMotor Protection and Monitoring
Motor Protection and Monitoring Motor Protection Circuit Breaker.1 Monitoring Relays Product Overview Monitoring Relays........................ Current Monitoring Relays..................................
More informationSECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS
SECTION 262816 - ENCLOSED SWITCHES AND CIRCUIT BREAKERS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division
More information4/8/ nd Annual OTCO WW Workshop W/WW Product Overview ACQ550. ABB Slide 1
4/8/2015 52 nd Annual OTCO WW Workshop W/WW Product Overview ACQ550 Slide 1 Drive Basics Why Use Adjustable Speed Drives? Reduced Energy Consumption Improved Process Control / Efficiency Increased Product
More informationPLT. Breaker-based transfer switch open, closed or soft transition amps. Specification sheet
Specification sheet PLT Breaker-based transfer switch open, closed or soft transition 800 3000 amps Description PLT breaker-based transfer switches are designed for operation and switching of electrical
More informationLine A. Inverse parallel scrs. Load a FUSION. Line B SCR POWER. O delta CONTROLLERS. Line c. inverse parallel scrs. Load C. FUSION Brochure Rev 3.
Line A Inverse parallel scrs Load a Line B FUSION SCR POWER O delta CONTROLLERS Line c inverse parallel scrs Load C FEATURES Auto-Ranging Input Voltage 24-600 VAC, 45-65 Hz AC or DC Output AC Models: 50-1200
More informationThe Center of Automation with IEC Products. CENTERLINE Motor Control Center. Allen-Bradley Replacements
The Center of Automation with IEC Products CENTERLINE Motor Control Center Allen-Bradley Replacements 2 Continually enhanced since its introduction in 1971, CENTERLINE is the leading MCC in the North American
More informationModel KEP. Transfer Switch Standard Features. Automatic Transfer Switches Service Entrance Rated. Enclosed Contact Power Switching Units.
Model KEP Automatic Transfer Switches Service Entrance Rated Controller D Decision-Makerr MPAC 1500 Ratings Power Switching Device Molded case (MCCB) Insulated Case (ICCB) Current Voltage, Frequency 200
More informationGE Power Management. UR F60 Feeder Management Relay An integrated feeder protection and metering solution
UR An integrated feeder protection and metering solution Power to Manage your Facility Connectivity ModBus RTU MMS/UCA2 TM Protocols SI Compatibility Flexibility FlexCurves FlexLogic The first Relay designed
More informationModel KEP. Transfer Switch Standard Features. Automatic Transfer Switches Service Entrance Rated. Enclosed Contact Power Switching Units.
Model KEP Automatic Transfer Switches Service Entrance Rated Controller D Decision-Makerr MPAC 1500 Ratings Power Switching Device Current Voltage, Frequency Molded case (MCCB) Insulated Case (ICCB) 200
More informationFP6000. Type ID Units Writable Possible Values. Count. TCP Register
FP6000 Category System ID 1032 Vendor Name 32 ASCII no-units 1064 Model Name 32 ASCII no-units 1096 Display Name 32 ASCII no-units 1128 Device Type 32 ASCII no-units 1605 Field Replaceable Unit 1 UINT16
More informationFTA750 LIMITED SERVICE FIRE PUMP CONTROLLERS STANDARD SUBMITTAL PACKAGE
FTA750 LIMITED SERVICE FIRE PUMP CONTROLLERS STANDARD SUBMITTAL PACKAGE SBP750-51(B) FTA750 Full Voltage Starting Limited Service Electric Fire Pump Controllers Product Description Description Firetrol
More informationThe PCI Series. Precise power control for complex SCR applications. Phase Angle Fired SCR Power Controls AMPS VAC
The PCI Series Phase Angle Fired SCR Power Controls 25-1200 AMPS 120-600 VAC Precise power control for complex SCR applications. ROBICON 1996 Distributed Worldwide by www.mcgoff-bethune.com Applications
More informationProtect induction and synchronous motors with one relay.
SEL-710-5 Motor Protection Relay Protect induction and synchronous motors with one relay. Patented, accurate thermal protection improves motor availability for production. Synchronous motor protection
More informationMP-3000 Series Microprocessor-Based Motor Protective Relay
MP-3000 Series Microprocessor-Based Motor Protective Relay The power of fusion. 874 886 893 899 906 908 9 934 96 963 976 983 990 999 There s a certain energy at Eaton. It s the power of uniting some of
More informationEMS 1Ø, 120 ~ 230V, 1/10-25HP 3Ø, 200 ~ 600V, 1/2-300HP
ES, 120 ~ 230V, 1/10-25HP, 200 ~ 600V, 1/2-300HP ENERGY ANAGEENT STARTER T Smartstart THE OST INTELLIGENT STARTER YET Power metering, optional BACnet or odbus communications, and an intuitive interface
More information1.1. Contactors and Starters... Contents Description Relays and Timers... Miniature Controls... Manual Motor Protectors. XT IEC Power Control
. Contents Description Relays and Timers......................... Miniature Controls......................... Contactors and Starters.................... Thermal Overload Relays.................... C440/XT
More informationMP-4000 motor protection. Protection, control and diagnostics
MP-4000 motor protection Protection, control and diagnostics Multi-function motor protection Introducing Eaton s MP-4000 motor protection relay Eaton s MP-4000 motor protective relay combines all the features
More informationI.B. 29C893C. Instructions for Installation, Operation and Maintenance of Breaker Interface Module II
I.B. 29C893C Instructions for Installation, Operation and Maintenance of Breaker Interface Module II I.B. 29C893C Page iii WARRANTY AND LIABILITY INFORMATION NO WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING
More informationwww. ElectricalPartManuals. com Protective Relays PROTECTION AND CONTROL FUNCTIONS ADVANCED CAPABILITIES
Protective Relays Electrical Apparatus Capacitor Bank Protection Relay 165-440-900 Figure 1: Edison Idea Relay The capacitor bank protection relay is a member of Cooper Power Systems Edison Idea TM line
More informationInView Marquee Message Display
Installation Instructions InView Marquee Message Display Introduction These instructions show how to change the serial address and how to mount InView series signs with NEMA Types 4, 4X, and 12 enclosures.
More information750/760 Feeder Management Relay Instruction Manual
GE Digital Energy 750/760 Feeder Management Relay Instruction Manual Software Revision: 7.4x Manual P/N: 1601-0120-AK Manual Order Code: GEK-106471T GE Digital Energy 650 Markland Street Markham, Ontario
More informationMotor Protection Relay
Supersedes May 2016 Contents Description Page Key Features, Functions and Benefits.... 2 General Description.... 2 Features.... 3 Protection and Control Functions... 4 Monitoring and Metering.... 5 Communication
More informationEasy To Use OEMS Take Note
MA7200 Features Sensorless Vector Precise speed and torque control for the most demanding system performance. Simple set-up through autotuning function. The MA7200 can be operated in sensorless vector
More informationQuick Start Guide TS A
Quick Start Guide TS 930 125-630A DANGER HAZARD OF ELECTRICAL SHOCK, EXPLOSION, OR ARC FLASH Read and understand this quick start guide before installing and operating the transfer switch The installer
More informationMAINTENANCE MANUAL. EDACS REDUNDANT POWER SUPPLY SYSTEM 350A1441P1 and P2 POWER MODULE CHASSIS 350A1441P3, P4, AND P5 POWER MODULES TABLE OF CONTENTS
MAINTENANCE MANUAL EDACS REDUNDANT POWER SUPPLY SYSTEM 350A1441P1 and P2 POWER MODULE CHASSIS 350A1441P3, P4, AND P5 POWER MODULES TABLE OF CONTENTS SPECIFICATIONS*... 2 INTRODUCTION... 3 DESCRIPTION...
More informationSECTION 16496E ATS MOLDED CASE WITH ATC 900 CONTROLLER
ATS MOLDED CASE WITH ATC 900 CONTROLLER PART 1 GENERAL 01 02 03 04 SCOPE Furnish and install the low voltage automatic transfer switches having the ratings, features/accessories and enclosures as specified
More informationINTRODUCTION. The PL-50 MO and PM-250 families represent the. PM-250-H: Horizontal box. PM-250-V: Vertical box
INTRODUCTION The PL-50 MO units are available in the next mechanical version: The PL-50 MO and PM-250 families represent the different solutions that Team Arteche offers for motor protection. Both families
More informationSECTION SOLID-STATE REDUCED VOLTAGE STARTERS
SECTION 26 29 13.16 PART 1 - GENERAL 1.1 THE REQUIREMENT A. General: The CONTRACTOR shall provide solid-state reduced voltage motor starters, complete and operable, in accordance with the Contract Documents.
More informationSORDS ELECTRIC ~ MA7200. Sensorless Vector AC Inverter.
www.sordselectric.com MA7200 Sensorless Vector AC Inverter Features and Benefits Sensorless Vector The MA7200 has precise speed and torque control for the most demanding system performance and simple set-up
More informationType 4 Disconnect Enclosures
143 SAGINAW CONTROL & ENGINEERING STOCK PRICE LIST Saginaw Control & Engineering s are designed to work in a wide range of environments indoors or outdoors, and will house most standard types of disconnects
More informationRevolutionizing control wiring
SmartWire-DT Panel Wiring Solutions Revolutionizing control wiring 797-6925 Fax: (215) 221-1201 www.royalelectric.com SmartWire-DT Changing the way panels are wired. Reduce cost throughout the value chain.
More informationETM MD100 Drive System 1/2HP (370W) User Manual. Table of Contents. Drive Features
Table of Contents Drive Features... 1 Drive Specifications... 2 Certifications... 3 Installation - Drive Dimensions... 3 Motor Dimensions (mm)... 4 Drive Mounting... 4 Wiring... 5 I/O Terminals... 9 Menu...
More informationDistribution Protection Relay
contents Description Page Key Features, Functions and Benefits.......... 2 General Description........................ 2 Features................................. 3 Protection and Control Functions.............
More informationFTA1350 WYE-DELTA CLOSED FIRE PUMP CONTROLLERS STANDARD SUBMITTAL PACKAGE
FTA1350 WYE-DELTA CLOSED FIRE PUMP CONTROLLERS STANDARD SUBMITTAL PACKAGE NOTE: The drawings included herein are for standard controllers. Actual "as built" drawings may differ from those seen here. ASCO
More informationOne relay for safety and process continuity
Motor Management Relay One relay for safety and process continuity Improve safety at each motor control center (MCC) with secure, fast arc-flash detection. Use the enhanced thermal model for more precise
More informationCDW7. Standard: IEC Application. Standard and certification. International standard: IEC Approved certification: CB, CE, KEMA
Application Applied to power distribution of AC Hz/60Hz, rated operational voltage 400/ 690V, rated current 200A~6300A and lower For power distribution and protecting circuit and power supply equipment
More informationPART 1: GENERAL PART 2: PRODUCT. Effective: 12/29/10 Page 1 of 6 FECA-TE-104D
Specification Number: 23 09 33 Product Name: FRENIC-Eco AC Drives for Variable Torque Fan & Pump Applications (1-125Hp at 208/230V and 1-900Hp at 460V) PART 1: GENERAL 1.01 SUMMARY A. This specification
More informationFP5000. Refer to for the latest information on this constantly evolving product
FP5000 Refer to www.eatonelectrical.com for the latest information on this constantly evolving product FP5000 Product Overview Microprocessor design combines protection, metering and control into a single
More informationPowerXL DG1 Product Overview Eaton Corporation. All rights reserved.
PowerXL DG1 Product Overview Product line overview Machinery OEM drives DE1, DC1, DA1, M-Max HVAC drives H-Max General purpose industrial drives DG1, SVX High performance drives SPX, LCX, SPI Low harmonic
More informationREL52002 Easergy P3U30, 4L, 4U, 16DI/8DO, Uaux: V, DI: V, RS-485
Characteristics Easergy P3U30, 4L, 4U, 16DI/8DO, Uaux: 48-230V, DI: 220-230V, RS-485 Main Range of product Product or component type Relay application Device short name [Us] rated supply voltage Type of
More informationGE Multilin 350 Feeder Protection Relay Specifications
GE Multilin 350 Feeder Protection Relay Specifications The feeder protection relay shall provide primary protection of medium voltage distribution feeders. The relay shall be equipped with the following
More informationQuantum III. Compact DC Drive Package. Slitter DC Drive Package. Quantum III
Compact DC Drive Package The delivers a DC drive package that integrates the intelligence of the Mentor II with a space saving design that incorporates many accessories typically required in the North
More information24973 Circuit Breaker MINIATURE CIRCUIT BREAKER, 440VAC, 10A, CIRCUIT BREAKER TYPE: STANDARD
United States 24973 Circuit Breaker MINIATURE CIRCUIT BREAKER, 440VAC, 10A, CIRCUIT BREAKER TYPE: STANDARD Image not available Product Information Features and Specifications Approvals: IEC 60947-2 Rated
More informationSEM3 - Embedded Micro Metering Module
SEM - Embedded Micro Metering Module Quick Reference Guide and Installation Instructions Scan QR Code for more information usa.siemens.com/sem Installation! DANGER Hazardous Voltage. Will cause death or
More informationUsing the Bitronics 70 Series to Improve Local Monitoring and Control
Automate a Substation and Preserve the Electromechanical Relay Investment Part Two of Four Using the Bitronics 70 Series to Improve Local Monitoring and Control Paul Grabowski - Bitronics Senior Application
More informationDocument C0. Use for:
Date: July 27, 2015 Document C0 Use for: Connection of Electric Generation that will operate with an Open Transition (Category 1) between the Ameren System and the Generator or operate with a Synchronized
More informationIntegrated Multipoint Submetering
Integrated Multipoint Submetering Dwayne McGrody, Justin West February 14, 2017 2016 Eaton. All Rights Reserved.. Agenda What is Sub-metering? Energy Code Impact Why meter? Basic Metering Terms Multipoint
More informationMicroVersaTrip Plus & MicroVersaTrip PM Conversion Kits for Westinghouse Power Circuit Breakers
MicroVersaTrip Plus & MicroVersaTrip PM Conversion Kits for Westinghouse Power Circuit Breakers Easily replace electro-mechanical trip units with the latest electronic, digital trip unit technology Ensure
More informationAcquiSuite Ally 48 Advanced Branch Circuit Monitor
AcquiSuite Ally 48 Advanced Branch Circuit Monitor AMC48-MD AMC48-ED Split Core CT Split Core CT Ally Rogowski Rope CT DESCRIPTION The AcquiSuite Ally 48 is the perfect companion to the data acquisition
More informationWireless 0-1 ma Current Meter
The Leader in Low-Cost, Remote Monitoring Solutions Wireless 0-1 ma Current Meter 0-1 ma 0-1mA CURRENT METER General Description The Wireless 0-1 ma DC Current Meter is designed to work with the Flex-Core
More informationPump Data Sheet - Patterson HVAC Pumps Company: Intermountain Hydron Name: Cache County Mountain Crest Date: 09/24/2018
Pump Data Sheet - Patterson HVAC Pumps Company: Intermountain Hydron Name: Cache County Mountain Crest Date: 09/24/2018 Tags: P-8 1800RPM Premium Efficient Motor 460/3/60 Pump and Motor Weight: 183lbs
More informationType 4X S.S. Disconnect Enclosures
201 SAGINAW CONTROL & ENGINEERING STOCK PRICE LIST Saginaw Control & Engineering s Type 4X S.S.Disconnect Enclosures are designed to work in a wide range of environments indoors or outdoors, and house
More informationFM2. Economical and compact feeder protection for low voltage feeders. Digital Energy Multilin. Monitoring & Metering. Protection and Control
Key Benefits FM2 FEEDER Protection System Economical and compact feeder protection for low voltage feeders Comprehensive low voltage feeder management system - Integrated feeder protection and process
More information1.6. Counters, Panel Meters, Tachometers and Timers. Contents Description Fusion Integrated Machine Control Standards and Certifications...
.6 Contents Standards and Certifications............... Product Selection....................... Technical Data and Specifications........... Dimensions............................ Learn Online Page V3-T-04
More informationTransfer Switches Magnum-Based Designs
September 2011 Sheet 250 -Based Designs Floor-Standing General Description Floor-Standing Floor-Standing Transfer Switch General Description Taylor s transfer switches are designed for a variety of standby
More information3.3. Control Relays and Timers
. Contents Description easy500/700/800..... easy802/806 with SmartWire-DT.................... easyrelay and MFD Expansion Modules..... MFD-Titan Multi-Function s......... easyrelay Communication Modules........
More informationMotor Protection and Monitoring
Motor Protection and Monitoring Motor Protection Circuit Breaker Manual Motor Protector Overload Relay C440 C441, Motor Insight.1 Monitoring Relays Product Overview Monitoring Relays..............................
More informationMotor Protection and Monitoring
Motor Protection and Monitoring Motor Protection Circuit Breaker.1 Monitoring Relays Product Overview Monitoring Relays........................ Current Monitoring Relays..................................
More informationTransfer Switches 5.1 Transfer Switch Equipment Product Selection Guide... Product Description... Application Description...
.1 Transfer Switch Equipment Product Selection Guide.................................... Product Description....................................... Application Description......................................2
More informationwith Backlight Graphic LCD Screen
with Backlight Graphic LCD Screen ENERGY AND AUTOMATION POWER OF ENERGY SAVING For the control of energy distribution systems detecting when problems occur that could put the quality and availability of
More informationPower Xpert Branch Circuit Monitor
Technical Data TD150021E Power Xpert ranch ircuit Monitor Introduction The Power Xpert ranch ircuit Monitor (PX M) meter module strip provides SI 12.20 0.5% revenue class branch circuit metering in panelboard
More informationFeaturing Spectra RMS Breakers
8000-Line Motor Control Centers Featuring Spectra RMS Breakers Fully integrated capabilities make GE your complete motor control center supplier Order management Coordinated drawings Applications support
More informationADDITIONAL INFORMATION MODBUS INSTRUCTION MANUAL Request publication Request publication
BE1-GPS100 GENERATOR PROTECTION SYSTEM The BE1-GPS100 is a multifunction, programmable numerical protection, meter, and control relay. Functions provided include three phase voltage controlled, voltage
More informationU lity network. system Q sys. Interconnected P sys. P load Q load. P gen Q gen. Generator network
SIL-G Feeder & Generator Protection Relay RC FLSH Main characteristics The SIL-G is a relay for primary distribution which can protect a feeder by means of current and voltage functions. It is also provided
More informationSECTION ELECTRICAL CONTROL DEVICES
ELECTRICAL CONTROL DEVICES PART 1 GENERAL 01 02 03 04 05 SCOPE The Contractor shall furnish and install, where indicated on the drawings, equipment with electrical control devices installed as specified
More informationA New, Standalone 24 Vdc Field Power Supply Reduces Costs, Simplifies Connectivity for Distributed I/O Devices on Industrial Machinery
A New, Standalone 24 Vdc Field Power Supply Reduces Costs, Simplifies Connectivity for Distributed I/O Devices on Industrial Machinery While the use of distributed I/O control is increasing on industrial
More information