UL 489 Cable-In / Cable-Out Branch Circuit Breaker
|
|
- Todd Cain
- 6 years ago
- Views:
Transcription
1 Product Overview UL 9 Cable-In / Cable-Out Branch Circuit Breaker PRODUCT OVERVIEW Optimum and Efficient Protection Features Complete range of UL 9 listed DIN rail mounted miniature circuit breakers up to A current rating Standard ratings of kaic at / Vac Select amperages available at 1 kaic at / Vac and kaic at 1 Vdc Current limiting design provides fast short-circuit interruption that reduces the let-through energy, which can damage the circuit Suitable for branch circuit device protection Thermal-magnetic overcurrent protection Two levels of short-circuit protection, categorized by C and D curves Trip-free design breaker can not be defeated by holding the handle in the ON position Captive screws cannot be lost SWD (switching duty) suitable for switching fluorescent lighting loads (I n A) Fulfill UL 9, CSA C. No. and also IEC 09- Standard Optimum product quality, tested reliability and safety standards for best protection of personnel, installations and plant. Eaton s WMZ DIN rail mountable circuit breaker is designed for use in branch service applications. Powerful Offering for Machine and System Builders The WMZ is available with C and D characteristics in accordance with UL 9, CSA C. No.; UL, CSA C. No. and IEC 09-. These devices are CE marked. Typical Applications Feeder and Branch Circuit Protection Convenience receptacle circuits (internal/external) Motor control circuits Load circuits leaving the equipment (external) HACR equipment (heating, air conditioning, refrigeration) (internal/external) PLC I/O points Computers Power supplies Control instrumentation Relays UPS Power conditioners For use in applications for which UL or CSA C. No. are also allowed Field-installable shunt trip and auxiliary switch subsequent mounting Separate version for ring-tongue connection (Type WMZT.T), terminal screws can be removed (on both sides) Module width of only 1. mm (per pole) Contact Position Indicator (red/green) Easy installation on DIN rail Possibility for sealing the toggle in ON or OFF position WMZ Complies with the Latest National and International Standards Standards Feeder and Branch Circuit Protection UL 9 Standard for molded-case circuit breakers (MCCB) for feeder and branch circuit protection. Products meet the requirements of the National Electrical Code (NEC ). CSA C. No. Standard for molded-case circuit breakers (MCCB) for feeder and branch circuit protection (corresponds closely to UL 9 Standard). Products meet the requirements of the Canadian Electrical Code (CEC). RoHS These devices are RoHS compliant. 9
2 Product Selection UL 9 Cable-In / Cable-Out Branch Circuit Breaker PRODUCT SELECTION Tripping Curves to Choose From Eaton WMZ branch circuit breakers are available with C and D tripping characteristics. C-curve devices are suitable for applications where medium levels of inrush current are expected. Applications include small transformers, lighting, pilot devices, control circuits and coils. C-curve devices provide a medium magnetic trip point. D-curve devices are suitable for applications where high levels of inrush current are expected. The high magnetic trip point prevents nuisance tripping in high inductive applications such as motors, transformers and power supplies. Eaton WMZ devices are current limiting, which means they interrupt fault currents within one half cycle of the fault. Current limiting devices offer superior protection by reducing peak let-through current and energy. Device Printing on Front and Side Installation options These branch circuit breakers are available in two terminal configurations: standard box terminals that accept multiple conductors and ring-tongue terminals, ideally suited to demanding requirements of the semi-conductor industry. All breakers mount on standard mm DIN rail. Bus connectors and feeder terminal facilitate mounting and wiring of multiple miniature circuit breaker arrays in control panel assemblies. These circuit breakers can also be reverse feed. tripping characteristic acc. to UL 9 a conventional non-tripping current I nt = I N (T= ) b conventional tripping current I t = 1. I N : t < 1 h (T= ) c.0 I N : t = 1 1 s (T= ) Conductor Type instantaneous tripping acc. to IEC 09-1 d type C: I N : t > 0.1 s I N : t < 0.1 s e type D: I N : t > 0.1 s I N : t < 0.1 s Calibration Temperature Breaker Status Indicator Rated Current Rated Voltage ing System WMZ T 1 C T Breaker Family WMZ = WMZ UL circuit breaker a Limited curve and ampere offerings. Breaker Type T = kaic H = 1 kaic a D = kaic/dc ab b 1 Vdc for single-pole, 0 Vdc for two-pole in series. c Not offered for Type WMZD. Number of Poles 1 = Single-pole = Two-pole = Three-pole c Protective Curve C = C Curve ( X I n ) D = D Curve ( X I n ) c X0 = A 01 = 1A X1 = A 0 = A 0 = A 0 = A 0 = A 0 = A 0 = A 0 = A Ampere Rating = A = A = A = A = A = A 0 = 0A = A = A Terminal T = Ring terminals [blank] = Standard box terminals
3 Product Selection UL 9 Cable-In / Cable-Out Branch Circuit Breaker PRODUCT SELECTION WMZT Product Selection UL approved (UL 9) and CSA Certified (CSA C. No. -0) as branch circuit breakers Interrupting capacity: ka ; ka IEC 09 WMZT UL 9 Circuit Breakers kaic Current limiting device Optional connections for ring-tongue terminals WMZT UL 9 Circuit Breakers with Ring-Tongue Terminals kaic Amperes Single-Pole C Curve ( X I n 1 0 WMZT1CX0 WMZT1C01 WMZT1CX1 WMZT1C0 WMZT1C0 WMZT1C0 WMZT1C0 WMZT1C0 WMZT1C0 WMZT1C0 WMZT1C WMZT1C WMZT1C WMZT1C WMZT1C WMZT1C WMZT1C0 WMZT1C WMZT1C D Curve ( X I n 1 0 WMZT1DX0 WMZT1D01 WMZT1DX1 WMZT1D0 WMZT1D0 WMZT1D0 WMZT1D0 WMZT1D0 WMZT1D0 WMZT1D0 WMZT1D WMZT1D WMZT1D WMZT1D WMZT1D WMZT1D WMZT1D0 WMZT1D WMZT1D WMZTCX0 WMZTC01 WMZTCX1 WMZTC0 WMZTC0 WMZTC00 WMZTC0 WMZTC0 WMZTC0 WMZTC0 WMZTC WMZTC WMZTC WMZTC WMZTC WMZTC WMZTC0 WMZTC WMZTC WMZTDX0 WMZTD01 WMZTDX1 WMZTD0 WMZTD0 WMZTD0 WMZTD0 WMZTD0 WMZTD0 WMZTD0 WMZTD WMZTD WMZTD WMZTD WMZTD WMZTD WMZTD0 WMZTD WMZTD Three-Pole WMZTCX0 WMZTC01 WMZTCX1 WMZTC0 WMZTC0 WMZTC0 WMZTC0 WMZTC0 WMZTC0 WMZTC0 WMZTC WMZTC WMZTC WMZTC WMZTC WMZTC WMZTC0 WMZTC WMZTC WMZTDX0 WMZTD01 WMZTDX1 WMZTD0 WMZTD0 WMZTD0 WMZTD0 WMZTD0 WMZTD0 WMZTD0 WMZTD WMZTD WMZTD WMZTD WMZTD WMZTD WMZTD0 WMZTD WMZTDz Amperes Single-Pole C Curve with Ring-Tongue Terminals ( X I n 1 0 WMZT1CX0T WMZT1C01T WMZT1CX1T WMZT1C0T WMZT1C0T WMZT1C0T WMZT1C0T WMZT1C0T WMZT1C0T WMZT1C0T WMZT1CT WMZT1CT WMZT1CT WMZT1CT WMZT1CT WMZT1CT WMZT1C0T WMZT1CT WMZT1CT WMZTCX0T WMZTC01T WMZTCX1T WMZTC0T WMZTC0T WMZTC0T WMZTC0T WMZTC0T WMZTC0T WMZTC0T WMZTCT WMZTCT WMZTCT WMZTCT WMZTCT WMZTCT WMZTC0T WMZTCT WMZTCT Three-Pole WMZTCX0T WMZTC01T WMZTCX1T WMZTC0T WMZTC0T WMZTC0T WMZTC0T WMZTC0T WMZTC0T WMZTC0T WMZTCT WMZTCT WMZTCT WMZTCT WMZTCT WMZTCT WMZTC0T WMZTCT WMZTCT D Curve with Ring-Tongue Terminals ( X I n 1 0 WMZT1DX0T WMZT1D01T WMZT1DX1T WMZT1D0T WMZT1D0T WMZT1D0T WMZT1D0T WMZT1D0T WMZT1D0T WMZT1D0T WMZT1DT WMZT1DT WMZT1DT WMZT1DT WMZT1DT WMZT1DT WMZT1D0T WMZT1DT WMZT1DT WMZTDX0T WMZTD01T WMZTDX1T WMZTD0T WMZTD0T WMZTD0T WMZTD0T WMZTD0T WMZTD0T WMZTD0T WMZTDT WMZTDT WMZTDT WMZTDT WMZTDT WMZTDT WMZTD0T WMZTDT WMZTDT WMZTDX0T WMZTD01T WMZTDX1T WMZTD0T WMZTD0T WMZTD0T WMZTD0T WMZTD0T WMZTD0T WMZTD0T WMZTDT WMZTDT WMZTDT WMZTDT WMZTDT WMZTDT WMZTD0T WMZTDT WMZTDT For our complete product offering, see the Distribution Products Catalog (CA001E). 11
4 UL 9 Cable-In / Cable-Out Branch Circuit Breaker PRODUCT SELECTION WMZH Product Selection UL approved (UL 9) and CSA Certified (CSA C. No. -0) as branch circuit breakers Interrupting capacity: 1 ka ; ka IEC 09 Current limiting device Optional connections for ring-tongue terminals WMZH UL 9 Circuit Breakers 1 kaic WMZH UL 9 Circuit Breakers with Ring-Tongue Terminals Amperes Single-Pole Three-Pole Amperes Single-Pole Three-Pole C Curve ( X I n C Curve ( X I n WMZH1C WMZH1C WMZH1C WMZH1C WMZHC WMZHC WMZHC WMZHC WMZHC WMZHC WMZHC WMZHC WMZH1CT WMZH1CT WMZH1CT WMZH1CT WMZHCT WMZHCT WMZHCT WMZHCT WMZHCT WMZHCT WMZHCT WMZHCT D Curve ( X I n D Curve ( X I n WMZH1D WMZH1D WMZH1D WMZH1D WMZHD WMZHD WMZHD WMZHD WMZHD WMZHD WMZHD WMZHD WMZH1DT WMZH1DT WMZH1DT WMZH1DT WMZHDT WMZHDT WMZHDT WMZHDT WMZHDT WMZHDT WMZHDT WMZHDT WMZD Product Selection UL approved (UL 9) and CSA Certified (CSA C. No. -0) as branch circuit breakers Interrupting capacity: ka at 1 Vdc WMZD UL 9 Circuit Breakers kaic at 1 Vdc per pole 1 Vdc for single-pole, 0 Vdc for two-pole in series Current limiting device Amperes Single-Pole C Curve ( X I n 0 WMZD1C0 WMZD1C0 WMZD1C0 WMZD1C0 WMZD1C0 WMZD1C0 WMZD1C0 WMZD1C WMZD1C WMZD1C WMZD1C WMZD1C WMZD1C WMZD1C0 WMZD1C WMZD1C WMZDC0 WMZDC0 WMZDC0 WMZDC0 WMZDC0 WMZDC0 WMZDC0 WMZDC WMZDC WMZDC WMZDC WMZDC WMZDC WMZDC0 WMZDC WMZDC 1
5 UL 9 Cable-In / Cable-Out Branch Circuit Breaker PRODUCT SELECTION WMZ UL 9 Breakers Accessory/Description Two-pole contact or auxiliary contact/ Trip indicating contact Auxiliary contact Shunt trip 1 Vac Shunt trip 1 1 Vac Padlock hasp Busbar single-pole terminals Busbar single-pole 1 terminals Busbar single-pole 1 terminals Busbar two-pole terminals Busbar two-pole 1 terminals Busbar two-pole 1 terminals Busbar three-pole terminals Busbar three-pole 1 terminals Busbar three-pole 1 terminals Three-pole busbar shroud Extension terminal mm ( 1 AWG) Bus connector conductors up to 0 mm (~1/0 AWG) a Contact sales office for availability. WMZSAUXTRIP WMZTAUX WMZTST WMZTST1 WMZPLK WMZT1PT WMZT1P1T WMZT1P1T WMZTPT WMZTP1T WMZTP1T WMZTPT WMZTP1T WMZTP1T WMZTPSHROUD WMZTEXT WMZTBCON a Tripping Signal Switch WMZSAUXTRIP, WMZTAUX Design according to IEC/EN 09--1, IEC/EN 19 Field installable The specified minimum voltages are per contact take into account particularly in case of series connection Self-cleaning contacts Contact material and design particularly suitable for extra low voltage WMZSAUXTRIP: the function of one of the two change-over contacts can be switched from auxiliary switch to tripping signal switch Tripping signal contact transmits message of electric tripping, not mechanical switch-off Test key for contact function electrical tripping WMZTAUX: will allow for > Y/ Vac rating Connection Diagram.11 WMZSAUXTRIP.1/.1.1/.1 1 WMZTAUX Same Polarity Dimensions Miniature Circuit Breakers WMZ 1.1 Single-Pole Three-Pole. (.0). (.0). (.0) (9.) (.1).0 (1.).0 (1.) 1.9 (.).0.0 (1.) (1.).09 (.1)
6 Technical Data UL 9 Cable-In / Cable-Out Branch Circuit Breaker TECHNICAL DATA Miniature Circuit Breakers WMZ Connection Diagrams Dimensions (mm) Single-Pole Three-Pole. Miniature Circuit Breakers WMZ Description Electrical Specification Design according to UL 9, CSA C. No., IEC 09- Rated voltage WMZT IEC 9- Rated voltage WMZD Rated voltage WMZH IEC 9- Rated frequency Rated breaking capacity WMZT IEC 9- Rated breaking capacity WMZH IEC 9- Characteristic Endurance Line voltage connection Mechanical Frame size Device height Device width Mounting Upper and lower terminals Terminal capacity Terminal fastening torque Mounting Calibration temperature UL 9, CSA C. No. IEC 09- kaic at /V from A to A kaic at Vac for A kaic at Vdc per pole kaic at / Vac kaic at 1 Vdc per pole (two poles maximum) kaic at 0 Vdc with two poles connected in series 1 kaic at /V at listed amperages kaic at / Vac 0/0 Hz ka ka 1 ka ka C, D,000 operations Suitable for reverse feed mm mm 1. mm per pole Quick fastening with two lock-in positions on IEC/EN 0 Open mouth/lift terminals Single-wire Two-wire AWG 1-1: 1 lb-in AWG -: lb-in AWG : lb-in Independent of position C 0 C AWG 1 AWG 1 Power Loss at l n Characteristic C Single- Two- Pole Pole I n [A] Three- Pole Characteristic D Single- Two- Pole Pole Three- Pole P [W] P [W] P [W] P [W] P [W] P [W
7 UL 9 Cable-In / Cable-Out Branch Circuit Breaker TECHNICAL DATA Let-Through Energy Characteristic C ( A), V Characteristic C (A), V Characteristic D ( A), V Characteristic D (A), V
8 Accessories UL 9 Cable-In / Cable-Out Branch Circuit Breaker ACCESSORIES Dimensions (mm) WMZT T WMZT 1T WMZTPSHROUD 99, 1, 1,, 1, x1,= 1, 11x1,=19,. WMZT 1T,, WMZTEXT 1,,, 1, 1x1,=99, 1, WMZTEXT Description UL 9 IEC/EN 09- # 1 AWG 0/ C Cu. mm 0/ C Cu in 1 mm Lockout Attachment WMZPLK Tested according to UL A # 1 AWG. Nm UL B # 1 AWG. Nm UL E # 1 AWG Nm Tightening torque of terminal screws
9 Technical Data UL 9 Cable-In / Cable-Out Branch Circuit Breaker Influence of Ambient Temperature T on Load Carrying Capacity I n (A) at Higher Ambient Temperature Device Market Current Rating I n (A) at C C C C 0 C C 0 C C 0 C TECHNICAL DATA Load Factor KT [I/I N ] Ambient Temperature T [ C] Maximum Load I L at ambient temperature T: I L (T) = I N K T (T) 1
10 UL 9 Cable-In / Cable-Out Branch Circuit Breaker ACCESSORIES Accessories Description WMZSAUXTRIP WMZTAUX Electrical Contact function CO 1NO + 1NC Rated voltage 0V 0V Frequency 0/0 Hz 0/0 Hz Rated current A A Rated thermal current I th A A Utilization category AC rated operational current I e A/0 Vac A/0 Vac Utilization category AC rated operational current I e A/0 Vac A/0 Vac Utilization category DC1 rated operational current I e A/1 Vdc A/1 Vdc 0.A/ Vdc Rated insulation voltage U I 0 Vac 0 Vac Minimum operational voltage per contact U min Vdc Vdc Minimum operational current I min ma DC ma AC/DC Rated peak withstand voltage U imp (1./0µ). kv kv Conditional short-circuit current I k with backup fuse A 1 ka 1 ka Max. backup fuse, overload and short circuit A gl Mechanical Tripping indicator electrical tripping Blue/white Frame size mm mm Device height 0 mm 0 mm Device width. mm (MU). mm (MU) Mounting Onto switching device Degree of protection, built-in IP IP Terminal protection Finger and hand touch safe according to BGV A, ÖVE-EN Terminals Lift terminals Lift terminals Terminal capacity 1 AWG. mm Finger and hand touch safe according to BGV A, ÖVE-EN Terminal screws M (posidrive Z0) M (posidrive Z0) Fastening torque of terminal screws lb-in Max. 1. Nm 1
1.2. Miniature Circuit Breakers and Supplementary Protectors. Contents. WMZ Circuit Breaker. UL 489 DIN Rail Miniature Circuit Breakers
.2 WMZ Circuit Breakers Contents Description WMZ Circuit Breaker Standards and Certifications.............. Selection................ Product Selection....................... Accessories...........................
More informationProduct Guide. UL 489 DIN rail miniature circuit breakers
Product Guide UL 489 DIN rail miniature circuit breakers UL 489 DIN rail miniature circuit breakers Product Overview................................................ 2 Product Selection WMZT 10 kaic at
More informationUL 489 DIN Rail Miniature Circuit Breakers
UL 489 DIN Rail Miniature Circuit Breakers Product Overview................................................ 2 Product Selection................................................ 4 Accessories.....................................................
More informationUL 489 DIN Rail Miniature Circuit Breakers
UL 9 DIN Rail Miniature Circuit Breakers Product Overview................................................ Product Selection................................................ Accessories.....................................................
More informationMiniature Circuit Breakers and Supplementary Protectors. Contents
. Optimum and Efficient Protection for Every Application Product Overview Features Optimum product quality, tested reliability and safety stand for best protection of personnel, installations and plant.
More informationUL 489 DIN rail branch circuit breakers
UL 9 DI rail branch circuit breakers FAZ-A circuit breakers Product Overview UL 9 DI rail branch circuit breakers FAZ-A circuit breakers PRODUCT OVERVIEW Optimum and efficient protection Optimum product
More information1.3. Miniature Circuit Breakers and Supplementary Protectors. Contents. WMZS Circuit Breaker. UL 1077 DIN Rail Supplementary Protectors
. Miniature Circuit Breakers and Supplementary Protectors UL 077 DIN Rail Supplementary Protectors WMZS Circuit Breakers Contents Description WMZS Circuit Breaker Standards and Certifications................
More informationClose Protection from Moeller. miniature branch circuit breakers miniature supplementary protectors
Close Protection from Moeller miniature branch circuit breakers miniature supplementary protectors FAZ branch circuit breakers General Information... Selection Tables Trip Characteristic C - Box terminals...
More informationProduct Guide. UL 1077 DIN Rail Supplementary Protectors
Product Guide UL 0 DIN Rail Supplementary Protectors UL 0 DIN Rail Supplementary Protectors Product Overview... Product Selection WMZS B Curve ( X I n Current Rating)..............................................
More informationApplying branch circuit breakers and supplementary protectors in North America
Product Application AP01102005E WMZT WMZS Applying branch circuit breakers and supplementary protectors in North America Introduction Eaton offers two types of miniature circuit breakers for use in North
More informationBulletin 1489 Circuit Breakers. Selection Guide
Bulletin 1489 s Selection Guide Overview/Description Bulletin 1489-A s Energy-limiting design protects downstream components better than conventional breakers during short circuits Field-mountable options
More information60103 Circuit Breaker
6003 Circuit Breaker United States MINIATURE CIRCUIT BREAKER, 20/240VAC, 2A, CIRCUIT BREAKER TYPE: STANDARD Image not available Product Information Features and Specifications Circuit Breaker Type: Standard
More informationFAZ Supplementary Protectors, FAZ Miniature Circuit Breakers, P2 Disconnect Switches Overview
FAZ Supplementary Protectors, FAZ Miniature Circuit Breakers, P2 Disconnect Switches Overview Supplementary Protectors / Miniature Circuit Breakers Page System overview 10/003 10/001 Supplementary protectors
More informationWMS SUPPLEMENTARY PROTECTORS
WMS Supplementary Protectors Overview WMS SUPPLEMENTARY PROTECTORS Product Specification The WMS Supplementary Protector is a dual-rated product for both AC and DC supplies, in accordance with UL 1077
More information1492-SP Supplementary Protectors
Dual terminals provide wiring/bus bar flexibility and clamp from both sides to improve connection reliability Approval marks are easily visible on dome Terminal design helps prevent wiring misses Scratch-
More informationMULTI 9 System Catalog UL Recognized NC100H Supplementary Protectors
B Curve NC100H Supplementary Protectors Rating 1P 2P 3P 4P 80 MG27164 MG27175 MG27186 MG27197 MULTI 9 System Catalog UL Recognized NC100H Supplementary Protectors C Curve NC100H Supplementary Protectors
More informationApplying branch circuit breakers and supplementary protectors in North America
Supersedes June 2017 FAZ-NA-L FAZ-NA FAZ Applying branch circuit breakers and supplementary protectors in North America Introduction Eaton offers three types of miniature circuit breakers for use in North
More informationMG24434 Supplementary Protector SUPPLEMENTARY PROTECTOR, 240VAC, 16A, CIRCUIT BREAKER TYPE: STANDARD
United States MG24434 Supplementary Protector SUPPLEMENTARY PROTECTOR, 240VAC, 16A, CIRCUIT BREAKER TYPE: STANDARD Product Information Features and Specifications For Use With: OEM Panels Approvals: UL
More informationSelection Guide. Control Circuit and Load Protection. Allen-Bradley 1489-M2C020
Selection Guide Control Circuit and Load Protection Circuit Protection Portfolio 1489-M Circuit Breakers Approved for branch circuit protection in the United States and Canada, and certified as Miniature
More informationMULTI 9 System Catalog UL Recognized C60N Supplementary Protectors
UL Recognized C60N Supplementary Protectors B Curve C60N Supplementary Protectors 1 MG24110 MG24125 MG24140 MG24155 15 MG17406 MG17436 MG17461 1.2 MG17402 MG17432 16 MG24118 MG24133 MG24148 MG24163 1.5
More information24973 Circuit Breaker MINIATURE CIRCUIT BREAKER, 440VAC, 10A, CIRCUIT BREAKER TYPE: STANDARD
United States 24973 Circuit Breaker MINIATURE CIRCUIT BREAKER, 440VAC, 10A, CIRCUIT BREAKER TYPE: STANDARD Image not available Product Information Features and Specifications Approvals: IEC 60947-2 Rated
More informationIssued February DATA SHEET 5SX2 MCB. Based on Siemens Industrial Control Catalog
Issued February 2011 DATA SHEET 5SX2 MCB Based on Siemens Industrial Control Catalog General Data Trip characteristics Tripping characteristics acc. to EN 60 898 Tripping characteristic A, -5 Type A characteristic
More informationApplication Switchgear for industrial and advanced commercial applications. U e V AC 277/480 Y V DC 60
DATASHEET - FAZ-C5/2-RT Miniature circuit breaker (MCB), 5A, 2p, C-Char, AC Part no. FAZ-C5/2-RT Catalog No. 102203 Eaton Catalog No. FAZ-C5/2-RT EL-Nummer 1691799 (Norway) Similar to illustration Delivery
More informationMULTI 9 System Catalog
MULTI 9 System Catalog Class 80 CONTENTS Page Schneider Electric Brands Section Introduction... Section UL Rated Protection Devices... Section IEC 097- Rated Protection Devices... Section IEC Rated Ground-fault
More informationSelection Guide. Control Circuit and Load Protection
Selection Guide Control Circuit and Load Protection Circuit Protection Portfolio 1489-M Circuit Breakers Approved for branch circuit protection in the United States and Canada, and certified as Miniature
More informationControl Circuit and Load Protection Products
Selection Guide Control Circuit and Load Protection Products Bulletin Numbers 188, 1489, 1492, 1692 Circuit Protection Portfolio 1489-M Circuit Breakers Approved for branch circuit protection in the United
More informationMini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protectors Specifications Bulletin Number 1492, 1692
Technical Data Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protectors Specifications Bulletin Number 1492, 1692 Topic Page 1489-M Miniature Circuit Breakers 1 1492-SP Supplementary Protectors
More informationSelection Guide. Control Circuit and Load Protection
Selection Guide Control Circuit and Load Protection Circuit Protection Portfolio 1489-M Circuit Breakers Approved for branch circuit protection in the United States and Canada, and certified as Miniature
More informationSection 4 Ground-Fault Protection Devices
Multi 9 System Catalog Section 4Ground-Fault Protection Devices Section 4Ground-Fault Protection Devices Selection Table The Multi 9 System includes one UL Listed and three IEC rated product families that
More informationJtec 10kA Miniature Circuit Breaker
Jtec 0kA Miniature Circuit Breaker EN 60898 The Jtec range has been enthusiastically adopted by a diverse range of customers seeking a cost effective 0kA performance. Jtec MCBs are available in a wide
More informationTeSys IEC Contactors and Overload Relays
TeSys IEC Contactors and Overload Relays Making High-Fault Short-Circuit Current Ratings Simple Schneider Electric is an industry leader in IEC contactors and overload relays, and is recognized as the
More informationResidual Current Devices. Residual Current Devices FRCmM-NA according to UL1053 & IEC/EN 61008
Residual Current Devices FRCmM-NA according to UL1053 & IEC/EN 61008 Wide range of compact types of RCDs serving as fault-current and additional protection according to UL1053 & IEC/EN 61008 standards,
More informationSupplementary Circuit Protectors Type GSB63
Supplementary Circuit Protectors Type GSB63 l Protection of circuits against short circuit and overload currents l UL1077 supplementary protection l 1,, 3 and 4 pole arrangements l 13 amperage sizes up
More informationAdd-on Residual Current Protection PBSM MW
SG_Bestell_MV_E.qxd 25.04.2005 09:39 Seite 36 Add-on Residual Current Protection PBSM MW By combining this device with a top-quality miniature circuit breaker of type PLS. (except PLSN) a top-quality RCBO
More informationAllen-Bradley 1492-RCDA4A40
Dual terminals provide wiring/bus bar flexibility and clamp from both sides to improve connection reliability Suitable for DIN Rail mounting Approval marks are easily visible on dome Terminal design helps
More informationOTEC Miniature Circuit Breakers (MCB) OTEC Miniature Circuit Breakers (MCB) OTEC Miniature Circuit Breakers (MCB) Areas of Application
Miniature Circuit Breakers Areas of Application Miniature circuit breakers (MCBs) of the N-System primarily protect cables and conductors against overload and short circuit. Thus, they also protect electrical
More informationApplication Switchgear for industrial and advanced commercial applications. U e V AC 240/ (per pole) I cs 7,5 ka
DATASHEET - FAZ-C16/1 Miniature circuit breaker (MCB), 16A, 1p, C-Char, AC Part no. FAZ-C16/1 Catalog No. 278561 Eaton Catalog No. FAZ-C16/1 EL-Nummer 0001695154 (Norway) Similar to illustration Delivery
More informationOVERLOAD RELAYS POWER & ACTUATION PROVEN. series
POWER & ACTUATION OVERLOAD RELAYS series Need reliable, accurate overload and phase-loss protection for your motors? c3controls Series Bimetallic Overload Relays provide unmatched protection and can be
More informationCombined RCD/MCB Devices FRBmM, 1+N-pole
Combined RCD/MCB Devices FRBmM, 1+N-pole SG13711 High-quality residual current device / miniature circuit breaker combination, line voltage-independent Contact position indicator red - green Fault current
More information29 $ Manual Motor Starters FREESHIPPING. MOTOR CONTROLS 25. Features: MMS-32H Frame. MMS-63H Frame.
www.factorymation.com/motorcontrols MOTOR CONTROLS 25 Manual Motor Starters High interrupt capacity Din rail and surface mounting Lockable handle (OFF position) IP20 finger safe terminals Class 10 thermal
More informationApplication Switchgear for industrial and advanced commercial applications. U e V AC 240/ (per pole)
DATASHEET - FAZ-C10/2 Miniature circuit breaker (MCB), 10A, 2p, C-Char, AC Similar to illustration Part no. FAZ-C10/2 Catalog No. 278756 Eaton Catalog No. FAZ-C10/2 EL-Nummer 1695166 (Norway) Delivery
More informationST 200 M data sheet System pro M compact miniature circuit breakers for supplementary protection acc. to UL 1077
MINIATURE CIRCUIT BREAKERS ST 200 M data sheet System pro M compact miniature circuit breakers for supplementary protection acc. to UL 1077 The ST 200 M miniature circuit breaker provides supplementary
More informationMulti 9 System Catalog
Multi 9 System Catalog Catalog 0860CT00 R07/4 04 Class 860 CONTENTS CONTENTS Description............................................. Page Description Page Introduction..................................................7
More informationMotor-protective circuit-breaker, 3p, Ir=16-25A, screw connection. Product range PKZM4 motor protective circuit-breakers up to 65 A
DATASHEET - PKZM4-25 Delivery program Motor-protective circuit-breaker, 3p, Ir=16-25A, screw connection Part no. PKZM4-25 Catalog No. 222352 Eaton Catalog No. XTPR025DC1NL EL-Nummer 0004355158 (Norway)
More informationDescription Basic devices with positive operation contacts. Standards IEC/EN 60947, EN , VDE 0660, UL, CSA
Delivery program Contactor relay, 3N/O+1N/C, DC current Part no. DILA-31(24VDC) Catalog No. 276379 Eaton Catalog No. XTRE10B31TD EL-Nummer 4130206 (Norway) Product range DILA relays Application Contactor
More informationMiniature Circuit Breakers for Railway Applications
Siemens AG 00 for Railway Applications BETA Low-Voltage Circuit Protection The miniature circuit breakers are used in fixed railway systems and rolling stock for protecting system components against overcurrent
More informationProtection Equipment
Protection Equipment Price groups 41B, 41E, 41F, 41G, 41H, 41J, 42F, 42J, 143, 401 /2 Introduction Motor starter protectors/ circuit breakers SIRIUS 3RV2 motor starter protectors up to 40 A / General data
More informationMini Contactors & Overloads
108 Mini s & Overloads GMC-12M Surface or DIN rail mountable UL508 compliant 1/ to 7-1/ 50/60Hz AC and DC versions available Direct-mounting overloads RoHS compliant Auxiliary contacts standard (1 N.0.)
More informationResidual Current Devices drcm Digital
Digital Line voltage independent RCCB for fault or additional protection with additional digital features. System Monitoring: Preventive information / warning before the RCD trips in case of leakage currents.
More information209/219/229 Multi-Pole Circuit Protectors 202 branch circuit applications such as EDP, air conditioners, panel boards
The 29, E-Frame circuit breaker combines power switching with accurate, reliable circuit protection 29/29/229 Magnetic Circuit Protectors 99 in a compact single or multipole 249 Power Selector Breaker
More informationDIN Series MINIATURE CIRCUIT BREAKERS, RESIDUAL CURRENT CIRCUIT BREAKERS. Introducing the DIN Series High-quality, high-performance circuit breakers
DIN Series MINIATURE CIRCUIT BREAKERS, RESIDUAL CURRENT CIRCUIT BREAKERS Introducing the DIN Series High-quality, high-performance circuit breakers Features (1) All models fully comply with IEC regulations
More informationJ7MN. Ordering Information. Motor Protection Circuit Breaker. Model Number Legend. MPCB system. Options. Motor Protection Circuit Breaker J7MN I-1
Motor Protection Circuit Breaker J7MN ) MPCB system Rotary and switch types Rated operational current 32 A, 63 A and 00 A Switching capacity up to 00 ka/400 V Fixed short-circuit release = 3 x I u Overload
More informationBulletin 1492-MC 1492-MCGA, -MCEA 1492-SP
Bulletin Control Circuit and Load Protection Product Overview Bulletin -MC -MCGA, -MCEA -SP Type Branch Ground Fault Detection Features /V, V & Y/V rating A interrupt / in. per pole wide... A @ UL Circuit
More informationMotor protection relays
Thermal overload relays for currents between 0.09 and 420A Electronic thermal overload relays for currents between 0.4 and A Electronic thermal overload relays with selectable tripping class: 5--20-30
More informationAThink future. Switch to green. Mini Panel Board. Cost-effective, space-saving board up to 400A.
www.moeller.co.uk Mini Panel Board Cost-effective, space-saving board up to 400A Product Catalogue and Selection Guide Mini Panel Board Miniature Circuit Breakers Moulded Case Circuit Breakers XBoard Consumer
More informationMULTI 9 System Catalog
MULTI 9 System Catalog Class 80 CONTENTS Schneider Electric Brands Description Page SectionIntroduction... Section UL 89 Listed Circuit Breakers and UL 77 Recognized SupplementaryProtectors... SectionIEC097-RatedProtectionDevices...
More informationApplication Instantaneous release response current 5-10 x In. Switching capacity Switching Capacity 15 ka (IEC/EN ) U e V AC 230/400
Overcurrentswitch,10A,3p,C-Char,AC Partno. FAZ-C10/3 Articleno. 278869 CatalogNo. FAZ-C10/3 Similar to illustration Deliveryprogramme Product range FAZ Application Instantaneous release response current
More informationSECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS
SECTION 262816 - ENCLOSED SWITCHES AND CIRCUIT BREAKERS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division
More informationFor Sales and Support call KMParts.com (866)
Overcurrentswitch,5A,1p,B-Char,AC Partno. FAZ-B5/1 Articleno. 278528 CatalogNo. FAZ-B5/1 Similar to illustration Deliveryprogram Basic function Miniature circuit breakers Number of poles 1 pole Tripping
More information9926 Series Branch Rated Circuit Breakers AC Version
Branch Rated AC Version Hydraulic Magnetic Single pole and double pole versions 20/240 VAC, 50/60 Hz Up to 25A Just 3 mm wide Mounts on 35mm DIN-rail UL 489 listed, CSA C22.2 No. 5-02, CE VDE Ordering
More informationNF44E-.. / NFZ44E-.. Contactor Relays AC / DC Operated - with Screw Terminals
Technical Datasheet 1SBC1010D0201 28/03/11 NFE-.. / NFZE-.. Contactor Relays AC / DC Operated - with Screw Terminals NF(Z) contactor relays are used for switching auxiliary and control circuits. NF(Z)
More informationSentron 3VT circuit breakers Simply Smart: First choice for power distribution
s Sentron 3VT circuit breakers Simply Smart: First choice for power distribution www.siemens.com/industry Sentron 3VT Molded Case Circuit-Breakers - 10-1600Amperes With the standard line of 3VT molded-case
More informationCS8 Industrial Control Relays
CS8 Industrial Control Relays Despite increasing complexity, control systems and installations must become increasingly compact. And the CS8 Miniature Relay System packs maximum performance into minimum
More informationIntroduction Circuit Protection
Introduction Circuit Protection Weidmuller s DIN-rail mounted circuit breakers are available for use in applications where circuit protection must be able to distinguish between circuit overloads and short
More information3RM1 Hybrid Starters 6SIRIUS. contents. Industrial Controls Product Catalog 2017
3RM1 Hybrid Starters Industrial Controls Product Catalog 2017 Section contents 3RM1 Compact - Hybrid Starters Overview /2 General Data /3 Selection and ordering data /4 Accessories /5 - /9 Technical Data
More informationResidual Current Devices FRCdM Type B, B+ and Bfq Digital
Residual Current Devices FRCdM Type B, B+ and Bfq Digital All-current sensitive RCCB for fault or additional protection Digital Features System Monitoring: Preventive information / warning before the RCD
More informationlow voltage GLOBAL CATALOGUE RANGE Motor Control Contactors - Thermal Overload Relay s - Manual Motor Starters
CTLOGUE GLOBL RNGE 2. Motor Control Contactors - Thermal Overload Relay s - Manual Motor Starters 2. 2. Product Overview. 2.2 Overload Relay Setting Range 2. - 2.8 Product Specifications 2.9-2. Contactor
More informationMiniaturecircuitbreaker(MCB),16A,3p,B-Char,AC. Application Switchgear for industrial and advanced commercial applications.
Miniaturecircuitbreaker(MCB),16A,3p,B-Char,AC Similar to illustration Partno. FAZ-B16/3 CatalogNo. 278847 EatonCatalogNo. FAZ-B16/3 EL-Nummer 1695123 Deliveryprogram Basic function Miniature circuit-breakers
More informationSupplemental Protectors
compact S200 Series Miniature circuit breakers S200, S200P, S200U, S200UP Description The S2 Series of miniature circuit breakers offer a compact solution to protection requirements. The S2 devices are
More informationSafety relay emergency stop/protective door, 24VDC/AC, 4 enabling paths
DATASHEET - ESR5-NO-41-24VAC-DC Safety relay emergency stop/protective door, 24VDC/AC, 4 enabling paths Part no. ESR5-NO-41-24VAC-DC Catalog No. 118701 EL-Nummer (Norway) 0004133317 Delivery program Product
More informationResidual Current Devices FRCdM Type B, B+ and Bfq Digital
Residual Current Devices FRCdM Type B, B+ and Bfq Digital Line-voltage independent, all-current sensitive RCCB for fault or additional protection with additional digital features System Monitoring: Preventive
More informationDisconnect Switches. Safe Switching and Disconnecting
IB105-UK_U1_U4_Pfade.indd 2-3 14.04.2005, 16:51:30 Disconnect Switches Safe Switching and Disconnecting Disconnect Switches from Salzer are hand-operated switchgear for main circuits and are offered as
More informationSquare D General Purpose Relays
Square D General Purpose Relays Class 850R miniature control relays 850RS4 standard 850RS24 low level 850RS34 hermetically sealed Catalog 204 Contents Class 850R miniature control relays bbspecifications....................................................
More informationIELR Rail-Mount Series Magnetic Circuit Protectors
IELR Rail-Mount IELR Rail-Mount Series Magnetic Circuit Protectors Introduction 92 Single Pole 93 Specifications 94 Operating Characteristics 95 Delay Curves 96 Approvals & Decision Tables 200 IELR Series
More informationIELR Series
IELR Series Rail-Mount Magnetic Circuit Protectors Introduction Poles Specifications Operating Characteristics Delay Curves Approvals Decision Tables 6 62 63 64 65 69 70 IELR Series Rail-Mount Hydraulic
More informationPowerPact Q-Frame Molded Case Circuit Breakers and Switches (Types QB, QD, QG and QJ)
PowerPact Q-Frame Molded Case Circuit Breakers and Switches (Types QB, QD, QG and QJ) Catalog Class 0CT00R/0 0 CONTENTS Description..............................................Page Description.............................................
More informationQUINT-PS/ 1AC/24DC/20/CO
Extract from the online catalog QUINT-PS/ 1AC/24DC/20/CO Order No.: 2320898 DIN rail power supply unit 24 V DC/20 A/CO, dip-coated circuit board, primary-switched, 1-phase. For the first time, SFB (selective
More informationCircuit Breakers Type CTI 25M, CTI 45MB
Data sheet Circuit Breakers Type CTI 25M, CTI 45MB Circuit breakers for short circuit and overload protection of motor applications cover the current range 0.1 45 A (AC-3 rating). The product range is
More informationSolid-State Switching Devices
Overview 3RF21 3RF20 3RF22 3RF23 SIRIUS 3RF2 solid-state switching devices Solid-state switching devices for resistive loads Solid-state relays Solid-state contactors Function modules Solid-state switching
More information920 Remote Control (RC) Switches
920 Remote Control (RC) Switches ASCO is the global leader in power switching and controls ASCO 920 PRODUCT SPECIFICATIONS SWITCH ONLY (PANELBOARD MOUNTING) 1,2,3 () DIMENSIONS, IN.(MM) WIDTH HEIGHT DEPTH
More informationASCO 920 Remote Control (RC) Switches
Maximum reliability and excellent value ASCO 920 Remote Control (RC) Switches ASCO 920 Remote Control Switch in Type Enclosure The ASCO 920 is designed as a feeder disconnect switch for load capacities
More informationPositive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous
Safety relay for monitoring E-STOP pushbuttons. Approvals Unit features Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous 1 auxiliary contact (N/C), instantaneous Safe separation of
More informationMicro Contactor MA Series
Relay-sized contactor, making it the world s smallest >3mm contact clearance acc. to IEC 60335-1 for Safety Applications Reversing contactor with mechanical interlock 3 Pole and 1 Aux. Contact NO or NC
More informationApproved Standards. Motor Protection Circuit Breaker (MPCB) J7MN. MPCB system (motor protection CLASS 10) Auxiliary contact modules.
Motor Protection Circuit Breaker (MPCB) J7MN MPCB system (motor protection CLSS 0) Rotary and switch types Rated operational current = 2, 25, 50 and 00 Switching capacity up to 2.5 = 00 k/400 V Fixed short-circuit
More informationIDE Load break switches for machine control Remotely trippable switch from 32 to 160 A
The solution for Load break switches > Industry. > Non critical buildings. > Public Access Sites. > High Rise Buildings. ide_021_a_1_cat ide_022_a_1_cat IDE 4x40 A External operation IDE 4x40 A Direct
More information3 Pole Contactors with AC operating coils
1 3 Pole Contactors with AC operating coils Characteristics General Characteristics Switching Current 9A ~ Rated insulation voltage (Ui) (Conforming to IEC 158-1) V 750 IEC 60947-4 V 1000 Conforming to
More informationMotor protection circuit breakers
R Motor protection circuit breakers Motor protection circuit breakers are used for start-up and protection of electric motors (industry, small machines, external use, agricultural machines, compressors,
More informationUS BROCHURE. Circuit protection according to UL 489 and UL 1077
US BROCHURE Circuit protection according to UL 489 and UL 1077 2 CIRCUIT PROTECTION UL 489 AND UL 1077 CIRCUIT PROTECTION UL 489 AND UL 1077 3 Table of contents 004 006 Introduction 007 008 Product selction
More informationTime Delay Values (E-Series)
Time Delay Values (ESeries) AC Instantaneous 00 0 INSTANTANEOUS CURVE NO. 20 00 0 DC D.C. INSTANTANEOUS CURVE NO. 0 0. 0..0.0.00 200 300 400 500 700 800 900 0 200.00 200 300 400 500 700 800 900 0 200 Short
More informationTechnical data. Dimensions: see page 116. ): 4 kv Rated insulation voltage (U i Over-voltage category: Power supply. Rated operating voltage (Un):
Safety module CS AR-91, according to EN 81 Safety modules for the lift automatic floor levelling operation according to EN 81 Main functions For safety applications up to SIL 3 / PL e Choice between automatic
More informationSOCOMEC SIRCOVER MANUALLY OPERATED CHANGEOVER SWITCHES
MANALL OPERATED CHANGEOER SWITCHES are manually operated multipolar changeover switches. They changeover between two low voltage power circuits under load and provide safety disconnection. Application:
More informationSafe monitoring relays
monitor for safe standstill monitoring Approvals Block diagram Unit features Positive-guided relay outputs: 2 safety contacts (N/O), instantaneous 1 auxiliary contact (N/C), instantaneous LED indicator
More informationRiLine Compact The smart power distribution system
RiLine Compact The smart power distribution system 2 Power distribution in a confined space Rittal are the leading suppliers of reliable power distribution and backup systems for controlgear. The new RiLine
More informationIhr autorisierter Distributor: Neumüller Elektronik GmbH
IELR Series Rail-Mount Magnetic Circuit Protectors Introduction Poles Specifications Operating Characteristics Delay Curves Approvals Decision Tables 6 62 63 64 65 69 70 Neumüller Elektronik GmbH Gewerbegebiet
More informationAThink future. Switch to green. MCCB Panel Boards 400A / 630A / 800A.
www.moeller.co.uk MCCB Panel Boards 400A / 630A / 800A Product Catalogue and Selection Guide MCCB Panel Boards Moulded Case Circuit Breakers and Accessories XBoard Consumer Units XPole Miniature Circuit
More informationE-STOP relays, safety gate monitors
Safety relay for monitoring E-STOP pushbuttons, safety gates and light barriers. Approvals Block diagram Unit features Positive-guided relay outputs: 6 safety contacts (N/O), instantaneous 4 auxiliary
More informationThermal-Magnetic Circuit Breaker 4220-T...
Thermal-Magnetic Circuit Breaker 40-T... Description Single, double and three pole thermal-magnetic circuit breakers with high rupture capacity to UL 489 (5 ka), EN/IEC 60934 (6kA) and UL 077 (5 ka). With
More informationElectronic timer CT-ARS.11
2CDC 251 088 F0t07 Features Rated control supply voltage 24 240 V AC/DC Single function OFF delay timer without auxiliary voltage One device includes 7 time ranges (0.05 s 10 min) 1 c/o (SPDT) contact
More informationCircuit Breakers, Type CTI 25M, CTI 45MB, CTI 100
MAKING MODERN LIVING POSSIBLE Data sheet Circuit Breakers, Type CTI 25M, CTI 45MB, CTI 100 Circuit breakers for short circuit and overload protection of motor applications cover together with the circuit
More informationQUINT-PS/1AC/24DC/10. Extract from the online catalog. Order No.:
Extract from the online catalog QUINT-PS/1AC/24DC/10 Order No.: 2866763 DIN rail power supply unit 24 V DC/10 A, primary-switched mode, 1- phase. The SFB technology (Selective Fusebreaking Technology)
More information