Mounting kits for space-saving mounting in racks and cubicles and on walls IP54 protected mounting capability in cubicles

Size: px
Start display at page:

Download "Mounting kits for space-saving mounting in racks and cubicles and on walls IP54 protected mounting capability in cubicles"

Transcription

1 Page Revision: - Issued: December 00 Data subject to change without notice )HDWXUHV 0RXQWLQJNLWV 0RXQWLQJNLWV Mounting kits for space-saving mounting in racks and cubicles and on walls IP54 protected mounting capability in cubicles &RPPXQLFDWLRQ DFFHVVRULHV Communication accessories for adaption of common electrical interfacing techniques 7HVWVZLWFKPRGXOH Fail-safe testing of terminals, using test switch RTXP 4 Time saving while - all connections for test are made from the front - easy to move between terminals of the same type /RFNLQJVZLWFK Possibility to lock settings with key switch UDFNPRXQWLQJ Use the 9" rack mounting kit to mount the terminal in a standard rack. Combine the rack mounting kit with the side-by-side mounting kit to mount terminals or terminal and test switch in the same rack position. &RQQHFWRUV Flexible connection of signals and voltages - Screw compression type or spring compression type 6RIWZDUHWRROV Software tools to - configure the terminal - set parameters - monitor the terminal and the system - visualize and evaluate disturbance recordings Supervision and control via high voltage terminals (HV/Control package) Provides on request information from REx 5xx terminals Collection of disturbances from high voltage terminals Consists of standard library functions for easy application engineering of a station HMI The 9" rack mounting kit is available in three designs, suitable for /, 3/4 or full width terminals and consists of two rack flanges () with appropriate mounting details () for fastening to the terminal.

2 Page xx ai Figure : The rack mounting kit )OXVKPRXQWLQJ Use the flush- or semi-flush mount kit for installation in a panel cut out. The flush mounting kits are available in three designs, suitable for /, 3/4 or full width terminals and consists of four fasteners (4) with appropriate mounting details and a sealing strip () for fastening to the terminal (5). The semiflush mounting kit adds a distance frame () and an additional sealing strip (3). To receive IP54 class protection, an additional sealing must be ordered with the terminal. This sealing is factory mounted. :DOOPRXQWLQJ Use the wall mounting kit to projection mount the terminal on a wall. The wall mounting kit consists of a mounting bar pair () and a terminal bracket pair (). Screws for fastening of the terminal are included, but not wall fasteners Figure 3: The wall mounting kit xx eps 4 Figure : xx eps The flush mounting kit 6LGHE\VLGH PRXQWLQJ Use the side-by-side mounting kit to mount two terminals or a terminal and its corresponding test switch next to each other.

3 Page 3 The side-by-side mounting kit consists of two mounting plates ()(3) and eight fasterners ()(4). The side-by-side mounted units is mounted in a rack or cubicle using the appropriate kit, in this example the rack mounting kit (5) xx ai Figure 4: The side-by-side mounting kit 3URWHFWLRQFRYHUIRUUHDUDUHD Protection cover for rear area consisting of a steel sheet with a slot for cable entrance at the bottom part. xx vsd Figure 5: Protection cover for rear area

4 Page 4 &RPPXQLFDWLRQ DFFHVVRULHV &RQYHUWHUV :KHQ\RXKDYHWKH Short range optical fiber modem Short range optical fiber modem V.35/V.36 co- or contradirectional galvanic interface DQGQHHGWRFRPPXQLFDWH ZLWKHTXLSPHQWXVLQJ V.35, V.36 or RS-3C WKHQVHOHFWWKH V.35/V.36/RS-3C optoelectrical interface converter X. or G.703 X./G.703 opto-electrical interface converter G.703 V.35/V.36/G.703 interface converter 7DEOH 7KH99WR*LQWHUIDFHFRQYHUWHU 'DWD 9DOXH Transfer rates Synchronous; kbit/s, co- or contradirectional Timing Internal; controlled by the converter External; controlled by DTE signalling Power supply AC 0-30 VAC 50/60 Hz +/-0% DC 48 VDC +/-0% Connectors G.703 Self locking push-in connector V.36 5 pin D-sub male AC supply voltage DC supply voltage Standard mains connector XLR male receptable 7DEOH 7KH9956&RSWRHOHFWULFDOLQWHUIDFHFRQYHUWHU 'DWD 9DOXH Transfer rates 64 kbit/s Timing Internal; controlled by the converter External; controlled by DTE signalling Loop; derived from optical signal Fiber type Multimode 50/5 µm 6.6/5 µm Optical budget 5 db at 850 nm Power supply AC 0-30 VAC 50/60 Hz +/-0% DC VDC

5 Page 5 'DWD 9DOXH Connectors V pin male D-sub V pin male D-sub RS-3C 5 pin male D-sub Optical ST type AC supply voltage Standard mains connector DC supply voltage XLR male receptable 7DEOH 7KH;*RSWRHOHFWULFDOLQWHUIDFHFRQYHUWHU 'DWD 9DOXH Transfer rates Synchronous; 64 kbit/s, co- or contradirectional Timing Internal; controlled by the converter External; controlled by DTE signalling Loop; derived from optical signal Fiber type Multimode 50/5 µm 6.6/5 µm Optical budget 5 db at 850 nm Power supply AC 0-30 VAC 50/60 Hz +/-0% DC VDC Connectors X. 5 pin male D-sub RS pin male D-sub G pin modular RJ-45 jack 0 pin divisable screw connector Optical ST type AC supply voltage Standard mains connector DC supply voltage XLR male receptable

6 Page 6 )URQWFRPPXQLFDWLRQ The special front connection cable is used to connect a PC COM-port to to the optical contact on the left side of the local HMI. The cable includes an optical contact, an opto/electrical converter and an electrical cable with a standard 9-pole D-sub contact. This ensures a disturbance immune and safe communication with the terminal. xx Figure 6: Front connection cable 7DEOH )URQWFRPPXQLFDWLRQ )XQFWLRQ 9DOXH Protocol SPA Communication speed for the cable Kbaud Slave number to 899 Remote change of active group allowed Yes Remote change of settings allowed Yes 7HVWVZLWFK PRGXOH 7HVWVZLWFK The test switch, RTXP 4, is used to make it possible to test a relay in a failsafe way. Inserting a test-plug handle into the test switch automatically makes all preparations for test in the proper sequence. Blocked trip circuits, shortcircuited CT s, opened voltage circuits makes the relay terminals available for secondary injection test. '&VZLWFK The DC-switch is used to switch the DC-supply of the terminal ON/OFF. The DC-switch is of Combiflex type and needs a separate case with a Combiflex terminal base to be mounted. One possibility is to mount it in the same case as the test switch. The test switch module consists of a RHGS case with a test switch, RTXP 4, and a two-seat Combiflex terminal base mounted. An optional DC-switch occupies one seat if selected. All connections to the test switch module are made with Combiflex socket leads. Test contacts -4 of the test switch have 0 A terminals. The signal contact of the test switch and the Combiflex terminal base have 0 A terminals. For more details about the Combitest system and Combiflex system see related documents.

7 Page 7 Test switch DC switch 3 Spare seat 4 RHGS 6 case 3 4 xxmrk00037-da_.vsd Figure 7: Example of a test switch module /RFNLQJVZLWFK IRUVHWWLQJV To prevent unwanted changes of setttings, a key switch is used. The switch locks the settings via a binary input. The key switch is of Combiflex type. To install it, a separate case including a Combiflex terminal base is needed. One possibility is to install the key switch in the same case as the test switch. &RQQHFWRUV The connectors are used for voltage signals and binary in- and output signals. Use the ferrules to connect two wires to the same terminal point of a connector. Note that.5 mm is the maximum dimension allowed on these wires. A special crimping tool from Phoenix is needed to apply the ferrule to the wires. Use the bridge connector to jumper terminal points in a connector. (xx eps) Figure 8: Voltage connector

8 Page 8 Ferrules Bridge connector xx Figure 9: xx Connected cables with ferrules &RQILJXUDWLRQ DQGPRQLWRULQJ WRROV &$3 Use CAP 540 through all stages of a project, from engineering, configuring, programming and parameter setting to testing, commissioning, documentation and maintenance. You can use it to adjust the default configuration, or to make a new configuration. Use REVAL for visualization of disturbance recordings. REVAL can handle the following formats: REVAL format - this is a compressed format used by the REOR 00 and RCRA 00 disturbance recorders and the REx 5xx series protection and control terminals COMTRADE format - this is a standard format for disturbance recordings according to IEEE EVE format - this format is used by the INDACTIC family of disturbance recorders In addition to this there is a format conversion function in REVAL. This function can convert between any of above mentioned formats. The function can also convert to the following formats: DADISP (Mathematical signal analysis tool) MATLAB (Mathematical signal analysis tool) User defined ASCII format See related documents for more details about the tool, PC requirements etc. 606 Use the SMS 50 Substation Monitoring as an overall substation monitoring system that gives essential information about your electrical transmission and distribution process. This information consists of all measured and calculated data, such as indications, settings and diagnostic information available from ABB s protection and control terminals. SMS 50 can be used either locally at the station or remotely via a modem.using a public telephone net-work or a standard TCP/IP network for remote use, SMS 50 provides you the most cost-efficient way to realise substation monitoring. The SMS 50 Substation Monitoring System is the successor of the proven SMS 00 substation monitoring packages.

9 Page 9 0LFUR6FDGDWRROV See related documents for more details about the tool, PC requirements etc. UGHULQJ 0RXQWLQJDFFHVVRULHV DPH )RUFDVHVL]H 4XDQWLW\ $UWLFOHQXPEHU Protection cover for rear area: consisting of a steel sheet with a slot for cable entrance at the bottom part, fixing screws and assembly instruction. Mounting kit for 9 installation: consisting of two mounting angles, fixing screws and assembly instruction. Mounting kit for wall-mounting: consisting of mounting angles, mounting bars, fixing screws and assembly instruction. Mounting kit for flush installation: 6U x / 6U x 3/4 6U x / 6U x / 6U x 3/4 6U x / All sizes 6U MRK AA MRK AB MRK AC MRK CA MRK BA MRK BB MRK DA consisting of 4 fastener, sealing strip, fixing screws and assembly instruction. Mounting kit for semi-flush installation: All sizes MRK Y consisting of a distance frame, a sealing strip and the same parts as the flush installation kit. Mounting kit for side-by-side installation: 6U x / 6U x 3/4 6U x / MRK AK MRK AL MRK AM consisting of fixing plates, fixing screws and assembly instructions. RWH$OONLWVDUHFRPSOHWHLQFOXGLQJVFUHZV. All sizes MRK Z &RQYHUWHUV V.36 to G.703 converter with 48 VDC power supply MRK AA V.35/V.36/RS3C converter for short range fiber optical modem X./G.703 converter for short range fiber optical modem MRK CA MRK DA )URQWFRPPXQLFDWLRQ Front connection cable for PC (Opto/9-pole D-sub) Quantity: MKC

10 Page 0 7HVWVZLWFKPRGXOH Test switch module RTXP 4 in RHGS case 5XOH,IWKH7HVWVZLWFKPRGXOHLVVHOHFWHGH[WHUQDO HDUWKLQJPXVWEHVHOHFWHG With external earthing On/off switch for the DC-supply MRK CA RK 96 5-BC RK AA 7HVWVZLWFK Test switch RTXP 4 without RHGS case With external earthing Mounting kit for RTXP 4 in 4U rack assembly RK BC MRK BT RWH/HDGVZLWK$&RPELIOH[VRFNHWRQRQHHQGDQGLQVXODWLRQVWULSSHGRQWKHRWKHUHQG PXVWEHXVHGWRFRQQHFWWKHWHVWVZLWFKWRWKHWHUPLQDO7RFRQQHFWWKHVLJQDOFRQWDFWRIWKH WHVWVZLWFKDQGWKH'&VZLWFKOHDGVZLWK$&RPELIOH[VRFNHWRQRQHHQGPXVWEHXVHG /RFNLQJVZLWFKIRU VHWWLQJV Key-switch (for locked settings) Quantity: MRK A RWH7RFRQQHFWWKHORFNLQJVZLWFKOHDGVZLWK$&RPELIOH[VRFNHWRQRQHHQGPXVWEH XVHG &RQQHFWRUV Female connector Female connector Ferrule Bridge connector 8 terminals of screw compression type, conductor area max x.5 mm or x.0 mm 8 terminals of spring compression type, conductor area max x.5 mm or x 0.5 mm For x.5 mm conductors in screw compression terminal For terminals in the current circuit Quantity: MKC Quantity: MKC Quantity: MKC Quantity: MKC Bridge connector For 3 terminals Quantity: MKC Bridge connector For 4 terminals Quantity: MKC

11 Page &RQILJXUDWLRQDQG PRQLWRULQJWRROV CAP 540*., Configuration, programming and setting tool package See related documents 6XEVWDWLRQ PRQLWRULQJV\VWHP SMS 50 Program for SMS applications See related documents 5HODWHG GRFXPHQWV 7HFKQLFDORYHUYLHZEURFKXUH Platform Combiflex Combitest CAP 540. SMS 50 LIB 50 MRK BEN MRK BEN MRK 5 00-BEN MRK 5 -BEN MRS75973-MBG MRK BEN 0DQXIDFWXUHU $%%$XWRPDWLRQ7HFKQRORJ\3URGXFWV$% Control & Force Measurement Substation Automation SE-7 59 Västerås Sweden Tel: +46 (0) Fax: +46 (0)

Relion 650 series. Accessories, 650 series IEDs versions 1.0 to 1.3, ANSI Product Guide

Relion 650 series. Accessories, 650 series IEDs versions 1.0 to 1.3, ANSI Product Guide Relion 650 series Accessories, 650 series IEDs versions 1.0 to 1.3, ANSI Product Guide Contents 1. Available accessories...3 2. Mounting kit for 3U... 3 3. Mounting kits for 6U...4 4. RHGS cases...6 5.

More information

RELION 670/650 SERIES and SAM /650 series and SAM600-IO ANSI Accessories

RELION 670/650 SERIES and SAM /650 series and SAM600-IO ANSI Accessories RELION 670/650 SERIES and SAM600 670/650 series and SAM600-IO ANSI Accessories Contents 1. Available accessories... 3 2. Mounting kits... 3 3. RHGS cases...6 4. Test switch module... 6 5. Key switch for

More information

Modular identification system

Modular identification system Modular identification system (xx00000675.tif).jpg Application To be able to locate a relay unit in a protective relay, the unit is identified with a unique item designation. Furthermore, the electrical

More information

Relion 670 series. Busbar protection REB670 Installation and commissioning manual

Relion 670 series. Busbar protection REB670 Installation and commissioning manual Relion 670 series Busbar protection REB670 Document ID: 1MRK 505 180-UEN Issued: June 2010 Revision: C Product version: 1.1 Copyright 2010 ABB. All rights reserved Copyright This document and parts thereof

More information

Installation and commissioning manual REL 505-C1*2.3 Overcurrent protection terminal

Installation and commissioning manual REL 505-C1*2.3 Overcurrent protection terminal Installation and commissioning manual REL 505-C1*2.3 Overcurrent protection terminal About this manual DocID: 1MRK 506 094-UEN Issue date: June 2001 Status: New Version: 2.3 Revision: 00 ABB Automation

More information

- Optional separate COMBITEST test switch for reliable and safe testing 1MRK BEN

- Optional separate COMBITEST test switch for reliable and safe testing 1MRK BEN 5' Page 1 Revision B Issued: November 2003 Data subject to change without notice Three-Phase Terminal Three One-Phase Terminals )HDWXUHV High speed general differential protection. Minimal operating time

More information

Terminal tool box CAP 540*1.2

Terminal tool box CAP 540*1.2 Page 1 Issued: January 2003 Revision: A Data subject to change without notice Features Engineering tool box including disturbance upload, parameter setting, monitoring and configuration of REx 5xx transmission

More information

Accessories / 7XV5662

Accessories / 7XV5662 Accessories / XV Communication Converter XV-0AA00/GG for X. / RS / G.0. *) Fig. / Communication converter for X./ RS and G.0. The communication converter CC-XG for coupling to a communication network is

More information

Residual overvoltage relay

Residual overvoltage relay Page 1 Issued: April 1999 Status: New Data subject to change without notice Features Definite-time residual overvoltage earthfault protection and supervision Two independent operation stages, e.g. one

More information

SPA-ZC 17. Bus connection module SPA-ZC 17. User s manual and Technical description. Tx SC Rx BB BM MB MM SPA / RS 485 POWER SLAVE 1 MASTER 0

SPA-ZC 17. Bus connection module SPA-ZC 17. User s manual and Technical description. Tx SC Rx BB BM MB MM SPA / RS 485 POWER SLAVE 1 MASTER 0 SPA-ZC 17 Bus connection module User s manual and Technical description 1 2 3 4 5 6 7 8 O N SPA / RS 485 SPA 1100000 RS 485 0011110 SLAVE 1 MASTER 0 Tx SC Rx 2 5 Uaux 80...265 V ~ 18...80 V SPA-ZC 17 RS

More information

Power Quality and Recording Field Upgrade Available SEL-734, Standard Power Quality, 32 MB Memory SEL-734P, Advanced Power Quality, 128 MB Memory*

Power Quality and Recording Field Upgrade Available SEL-734, Standard Power Quality, 32 MB Memory SEL-734P, Advanced Power Quality, 128 MB Memory* SEL-734 Advanced Metering System with ANSI and IEC Class 0.2 Accuracy Standard with: ANSI Type 2 Optical Port, 2 Rear EIA-232 Ports, ACSELERATOR QuickSet SEL-5030 Software, Modbus RTU Communications Protocol,

More information

Substation Automation Products. High impedance differential busbar protection REB650 Relion 650 series

Substation Automation Products. High impedance differential busbar protection REB650 Relion 650 series Substation Automation Products High impedance differential busbar protection REB650 Relion 650 series One IED for a wide range of high impedance differential protection applications ABB introduces a new,

More information

Converter Box Data Sheet

Converter Box Data Sheet Page 1 from 6 Functions of the converter box The converter box is used to adapt physically two interfaces and to separate them galvanicly. It is configured as follows: Two interface slots can be used to

More information

Sensitive Earth-fault Relay SPAJ 111 C. Product Guide

Sensitive Earth-fault Relay SPAJ 111 C. Product Guide Issued: April 1999 Status: Update Version: C/12.04.2006 Data subject to change without notice Features Sensitive low-set neutral overcurrent stage with definite time characteristic High-set neutral overcurrent

More information

Substation Automation Products. Generator protection REG670/650 Relion 670 and 650 series

Substation Automation Products. Generator protection REG670/650 Relion 670 and 650 series Substation Automation Products Generator protection REG670/650 Relion 670 and 650 series A new protection standard for your valuable assets Based on ABB s extensive experience, REG670 and REG650 IEDs (Intelligent

More information

TRC-190 User s Manual

TRC-190 User s Manual First Edition, November 2008 www.moxa.com/product 2008 Moxa Inc. All rights reserved. Reproduction without permission is prohibited. The software described in this manual is furnished under a license agreement

More information

Fiber optic converter audio and CAN TA OPERATION MANUAL

Fiber optic converter audio and CAN TA OPERATION MANUAL Fiber optic converter audio and CAN TA-110.1 IOA110-1 March 2009 LANEX S.A., Technical support: tel. ul.ceramiczna 8, 20-150 Lublin tel. +48 81 443 96 36 Contents 1. General Characteristics.... 5 1.1.

More information

Earth-fault Relay SPAJ 110 C. Product Guide

Earth-fault Relay SPAJ 110 C. Product Guide Issued: April 1999 Status: Updated Version: C/12.04.2006 Data subject to change without notice Features Low-set neutral overcurrent stage with definite time or inverse time characteristic High-set neutral

More information

Voltage regulator. SPAU 341 C 1MRS MBG Issued: July 1998 Status: Revised Version: C/ Data subject to change without notice

Voltage regulator. SPAU 341 C 1MRS MBG Issued: July 1998 Status: Revised Version: C/ Data subject to change without notice Issued: July 1998 Status: Revised Version: C/08.10.2003 Data subject to change without notice Features Comprehensive voltage regulation for power transformers with on-load tapchangers in distribution substations

More information

Feeder protection relay SPAA 121 C. Product Guide

Feeder protection relay SPAA 121 C. Product Guide Issued: April 1999 Status: Updated Version: C/06.03.2006 Data subject to change without notice Features Two-phase low-set phase overcurrent unit with definite time or inverse time characteristic Two-phase

More information

Installation and commissioning manual REC 561*2.3 Control terminal

Installation and commissioning manual REC 561*2.3 Control terminal Installation and commissioning manual REC 561*2.3 Control terminal About this manual DocID: 1MRK 511 093-UEN Issue date: June 2001 Status: New Version: 2.3 Revision: 00 ABB Automation Products AB 2001

More information

TRC-190 User s Manual

TRC-190 User s Manual User s Manual Edition 3.2, May 2017 www.moxa.com/product 2017 Moxa Inc. All rights reserved. User s Manual The software described in this manual is furnished under a license agreement and may be used only

More information

SPA-ZC 200/SPA-ZC 202 IEC /SPA-gateway Modules. Installation Manual

SPA-ZC 200/SPA-ZC 202 IEC /SPA-gateway Modules. Installation Manual Issued: 29.03.2001 Version: A/29.03.2001 Checked: M.K. Approved: We reserve the right to change data without prior notice. Contents: 1. Safety information...4 2. Introduction...5 2.1. Contents of delivery...5

More information

DATA CONNECT ENTERPRISE

DATA CONNECT ENTERPRISE DATA CONNECT ENTERPRISE User s Manual IG202T and IGV23 Modem Document Number 520-01005-001 Rev. A DATA CONNECT Contents Contents... iii Figures... iv Chapter 1 Introduction... 5 Features...6 Applications...7

More information

Sensitive definite time or inverse time earth-fault stage for back-up residual earthfault

Sensitive definite time or inverse time earth-fault stage for back-up residual earthfault Issued: April 1999 Status: Updated Version: B/09.11.2001 Data subject to change without notice Features Sensitive restricted earth-fault protection stage for fast, selective earth-fault protection Sensitive

More information

Installing the DX LCD Display

Installing the DX LCD Display DX LCD Display User s Guide 3-1 Chapter 3 Installing the DX LCD Display Introduction Use the DX LCD Display as either a portable device, or permanently mount it in a panel or on the wall. For panel and

More information

Relion 670 series. Busbar protection REB670 ANSI Installation and commissioning manual

Relion 670 series. Busbar protection REB670 ANSI Installation and commissioning manual Relion 670 series Busbar protection REB670 ANSI Document ID: 1MRK505210-UUS Issued: February 2015 Revision: D Product version: 1.2 Copyright 2012 ABB. All rights reserved Copyright This document and parts

More information

PHOENIX CONTACT - 11/2007. This data sheet is only valid in association with the IB IL SYS PRO UM E user manual.

PHOENIX CONTACT - 11/2007. This data sheet is only valid in association with the IB IL SYS PRO UM E user manual. INTERBUS Inline Bus Coupler; Remote Bus Connections Via D-SUB Connectors REMOTE IN BA UL RD RC DSUB LD AUTOMATIONWORX Data Sheet 6362_en_03 PHOENIX CONTACT - 11/2007 REMOTE OUT Description The bus coupler

More information

Relion 650 series. 650 series 2.1 IEC Installation manual

Relion 650 series. 650 series 2.1 IEC Installation manual Relion 650 series 650 series 2.1 IEC Document ID: 1MRK 514 025-UEN Issued: January 2016 Revision: - Product version: 2.1 Copyright 2016 ABB. All rights reserved Copyright This document and parts thereof

More information

Modular E1 or Fractional E1 Access Unit. Dial-out for alarm report The E1 main link can be supplied with the following options:

Modular E1 or Fractional E1 Access Unit. Dial-out for alarm report The E1 main link can be supplied with the following options: FEATURES E1 or Fractional E1 access unit Supports one data port with selectable sync data rates: n x 56, n x 64 kbps Optional sub-e1 drop & insert port for PABX connectivity Single slot supports MEGAPLEX

More information

FOMi-40 Fiber Optic Modem with Remote Management

FOMi-40 Fiber Optic Modem with Remote Management Data Sheet FOMi-40 Provides a secure and long-range data link of up to 100 km (62 mi) Selectable data rates from 56 to 2048 kbps Multimode or single mode operation Extended transmission range up to 100

More information

IM IM in the RS485 variants features: 9-pin Sub-D socket for connection to PROFIBUS DP

IM IM in the RS485 variants features: 9-pin Sub-D socket for connection to PROFIBUS DP IM 151-1 Design The IM 151-1 interface modules are directly snapped onto the standard mounting rail. IM 151-1 modules feature: DIP switch for setting the PROFIBUS DP station address (1 to 125) Diagnostics

More information

Protection Relay RE_ 610. Installation Manual

Protection Relay RE_ 610. Installation Manual RE_ 0 MRS-MUM Issued:..00 Version: E/0..00 RE_ 0 Contents Copyrights.... Introduction........ This manual........ Use of symbols........... Intended audience........ Product documentation........... Document

More information

Combined Overcurrent and Earth-fault Relay SPAJ 140 C. Product Guide

Combined Overcurrent and Earth-fault Relay SPAJ 140 C. Product Guide Combined Overcurrent and Earth-fault Product Guide Issued: April 1999 Status: Updated Version: C/18.04.2006 Data subject to change without notice Features Three-phase, low-set phase overcurrent unit with

More information

INTEGRATED SYSTEMS AND CONTROL, INC. User s Hardware Manual. PCMNET V 7. xx

INTEGRATED SYSTEMS AND CONTROL, INC. User s Hardware Manual. PCMNET V 7. xx INTEGRATED SYSTEMS AND CONTROL, INC. User s Hardware Manual PCMNET V 7. xx INTEGRATED SYSTEMS AND CONTROLS, INC. PCMNET Users Manual Revised 2/4/2005 2003-2005 Integrated Systems and Control. Inc. PO Box

More information

Part No. Description Product Life Cycle Phase *) unit, 24 VDC, spring terminals. unit, 24 VDC, spring terminals, XC version

Part No. Description Product Life Cycle Phase *) unit, 24 VDC, spring terminals. unit, 24 VDC, spring terminals, XC version Ordering Data DATA SHEET TU520 Terminal Unit 1 Ordering Data Part No. Description Product Life Cycle Phase *) 1SAP 214 400 R0001 1SAP 414 400 R0001 TU520-ETH, PROFINET I/O terminal unit, 24 VDC, spring

More information

Synchro-check relay. Application

Synchro-check relay. Application Issued: April 1999 Status: Updated Version: B/08.11.2001 Data subject to change without notice Features Two identical operation stages allowing the closing conditions of two separate circuit breakers to

More information

Combined Overcurrent and Earth-fault Relay SPAJ 141 C. Product Guide

Combined Overcurrent and Earth-fault Relay SPAJ 141 C. Product Guide Combined Overcurrent and Earth-fault Product Guide Issued: April 1999 Status: Updated Version: C/19.04.2006 Data subject to change without notice Features Three-phase, low-set phase overcurrent unit with

More information

MSR 2400R. Rugged Power System for Military and Heavy Duty Applications

MSR 2400R. Rugged Power System for Military and Heavy Duty Applications MSR 2400R Rugged Power System for Military and Heavy Duty Applications 2400 W modular power system Power supply or battery charging systems Parallel n+1 connection, up to 90A Series connection, up to 360VDC

More information

Optimux-4T1 Four-Channel T1 Multiplexer

Optimux-4T1 Four-Channel T1 Multiplexer Data Sheet Optimux-4T1 Any Traffic Over Fiber Multiplexes four T1 channels over a fiber optics link with various fiber interfaces: multimode, single-mode (up to 120 km), and single-mode over single fiber

More information

1. Carefully unpack the um260 s shipping carton and check the contents for damage.

1. Carefully unpack the um260 s shipping carton and check the contents for damage. um260 Installation Manual um260 Installation Chapter 4 um260 MICRO MONITOR INSTALLATION This section of the um260 Micro Monitor Installation Manual describes the requirements and procedures for installing

More information

MSR 2400W. Multi purpose Power System for Telecom and Industrial Applications. Nominal Output Voltage. Voltage Setting Range

MSR 2400W. Multi purpose Power System for Telecom and Industrial Applications. Nominal Output Voltage. Voltage Setting Range MSR 2400W Multi purpose Power System for Telecom and Industrial Applications 2400 W modular system All voltages available 0 144VDC per module U and I adjustable from 0 to max value Hot-swap plug-in modules

More information

Npefm!681F! !!!681F!Gjcfspqujd!Usbotdfjwfs! Gjcfspqujd!Ofuxpsl!Tpmvujpo!! Model 570E Features. The Fiberoptic Communications Specialists

Npefm!681F! !!!681F!Gjcfspqujd!Usbotdfjwfs! Gjcfspqujd!Ofuxpsl!Tpmvujpo!! Model 570E Features. The Fiberoptic Communications Specialists !!!681F!Gjcfspqujd!Usbotdfjwfs! Gjcfspqujd!Ofuxpsl!Tpmvujpo!! The Fiberoptic Communications Specialists The Model 570E offers high-speed serial communication to meet the challenging needs of distribution

More information

Advant OCS. The Compact and Cost Effective Advant Controller. Advant Controller 210. Open Control System

Advant OCS. The Compact and Cost Effective Advant Controller. Advant Controller 210. Open Control System Advant OCS Open Control System Advant Controller 210 The Compact and Cost Effective Advant Controller Advant Controller 210 is a small, cost-effective system belonging to the Advant Controller family.

More information

RTU560 Remote Terminal Unit Connections and Settings

RTU560 Remote Terminal Unit Connections and Settings Remote Terminal Unit Connections and Settings Communication Unit 560CMG10 Application, characteristics and technical data have to be taken from the hardware data sheet: 560CMG10 1KGT 150 645 Operation

More information

Fiber Optic Selector Guide for Analog & Digital Data Links, Contact Closures & Multiplexers

Fiber Optic Selector Guide for Analog & Digital Data Links, Contact Closures & Multiplexers Fiber Optic Selector Guide for Analog & Digital Data Links, Contact Closures & Multiplexers Analog Data Links Multi-Channel Contact Closures Multiplexers Digital Data Links - Contact Closures Power Supply

More information

RTU560 Connections and Settings DIN Rail RTU 560CIG10

RTU560 Connections and Settings DIN Rail RTU 560CIG10 Connections and Settings DIN Rail RTU 560CIG10 Application, characteristics and technical data have to be taken from the hardware data sheet: 560CIG10 1KGT 150 719 Operation The 560CIG10 is a DIN rail

More information

Relay setting toolbox

Relay setting toolbox Relay setting toolbox CAP 501 Issued: May 1999 Status: Updated Version B/06.11.2001 Data subject to change without notice Features General parameter setting support for ABB protection relays and terminales

More information

CMU 100 RS232 to Singlemode Fiber Optic Converter User Manual

CMU 100 RS232 to Singlemode Fiber Optic Converter User Manual CMU 100 RS232 to Singlemode Fiber Optic Converter User Manual CMU 100 / 1.1.S - 0 CMU 100 / 7.1.S - 0 Company: Device: Document: Code: Version: Date: Ediseja 21 CMU 100 / 1.1.S - 0 User manual CMUMU11S

More information

PTC/PT100 board 2.0 Option

PTC/PT100 board 2.0 Option PTC/PT100 board 2.0 Option Instruction Manual - English PTC/PT100 board 2.0 Option Instruction Manual - English Document number: 01-3873-01 Edition: r1 Date of release: 2006-10-30 Copyright Emotron AB

More information

APS SCALE SERIES DIMENSIONS

APS SCALE SERIES DIMENSIONS APS SCALE SERIES DIMENSIONS 4300 Section page 4 Model APS4300 Recommended Column/Base Combinations 14 Atlas Column 20 Atlas Column 30 Atlas Column Atlas Scale Series Dimensions: 4300 OPTIONS 4300 Section

More information

F2238A and F2245A Fiber-Optic EIA-530/MIL-STD Modem Technical Manual

F2238A and F2245A Fiber-Optic EIA-530/MIL-STD Modem Technical Manual F2238A and F2245A Fiber-Optic EIA-530/MIL-STD-188-114 Modem Technical Manual Revision C October 2013 VERSITRON, Inc. 83 Albe Drive / Suite C Newark, DE 19702 www.versitron.com PROPRIETARY DATA All data

More information

Kilomux-2100/2104. Data, Voice, Fax and LAN Integrating Modular Multiplexer

Kilomux-2100/2104. Data, Voice, Fax and LAN Integrating Modular Multiplexer Data Sheet Kilomux-2100/2104 Data, Voice, Fax and LAN Integrating Modular Multiplexer Maximized utilization of main-link bandwidth and high-quality low bit rate voice Fractional E1/T1, switched or leased

More information

IT power distribution Power distribution units (PDU) Basic. Versions available:

IT power distribution Power distribution units (PDU) Basic. Versions available: IT PDU Basic 1 U With its IT PDU Basic 1 U, BACHMANN provides a huge choice of PDUs in a high-quality aluminium profile. With their extremely compact size of just 1 height unit, mm in depth and 1" in width,

More information

Data communication and reporting unit

Data communication and reporting unit SRIO 500M Data communication and reporting unit User s manual and Technical description SRIO 500M FAULT ON 1 2 SERIAL IF 4 LOCAL 1 2 3 4 5 6 7 8 1 0 0542A 1MRS 750540-MUM EN Issued 1996-10-23 Modified

More information

REL 551*2.3 Line differential protection terminal

REL 551*2.3 Line differential protection terminal ,QVWDOODWLRQDQGFRPPLVVLRQLQJPDQXDO REL 551*2.3 Line differential protection terminal $ERXWWKLVPDQXDO Document No: 1MRK 506 078-UEN Issued: March 2003 Revision: B Copyright 2003 ABB. All rights reserved.

More information

Han-Brid. Contents Han-Brid Features Han-Brid Data interfaces Han-Brid Overview Han-Brid Cu

Han-Brid. Contents Han-Brid Features Han-Brid Data interfaces Han-Brid Overview Han-Brid Cu Contents Page Features... 19.02 Data interfaces... 19.03 Overview... 19.04 Cu... 19.06 F.O.... 19.08 Quintax 3 A... 19.10 RJ45 C... 19.12 USB / FireWire... 19.14 Han 4 A SC... 19.16 Hoods/Housings... 19.18

More information

CMU 100 RS485 to 7x, 6x, 5x, 4x Multimode Fiber Optic Star Coupler User Manual

CMU 100 RS485 to 7x, 6x, 5x, 4x Multimode Fiber Optic Star Coupler User Manual CMU 100 RS485 to 7x, 6x, 5x, 4x Multimode Fiber Optic Star Coupler User Manual CMU 100 / 2.5.6.6.6.6.6.6.6 12, CMU 100 / 8.5.6.6.6.6.6.6.6 12, CMU 100 / 2.5.6.6.6.6.6.6 12, CMU 100 / 8.5.6.6.6.6.6.6 12,

More information

SUNCLIX Connection technology for photovoltaics

SUNCLIX Connection technology for photovoltaics SUNCLIX Connection technology for photovoltaics Connection technology for photovoltaics Are you looking for innovative and reliable connection technology for your PV modules, inverters or the complete

More information

IP68 Sealed - Mini USB Buccaneer

IP68 Sealed - Mini USB Buccaneer IP68 Sealed - IP68 Over moulded assembly provides IP68 cable seal Coupling ring, screw thread provides secure cable coupling Mini USB connector O ring maintains IP68 seal at connector interface Mini USB

More information

Digital Lighting Systems, Inc.

Digital Lighting Systems, Inc. , Inc. PD402-DMX Four Channel Dimmer and Switch Packs 4 x 2.5 Amps @ 6VDC to 24 VDC DMX52 compatible DMX52 4 x 2.5 Amps Dimmer Pack C UL US LISTED Digital Lighting Systems, Inc. USER'S MANUAL User's Manual

More information

Relion 615 series Line Differential Protection and Control RED615 Ver. 2.0 Technical Presentation

Relion 615 series Line Differential Protection and Control RED615 Ver. 2.0 Technical Presentation Relion 615 series Line Differential Protection and Control RED615 Ver. 2.0 Technical Presentation ABB Oy Distribution Automation July 1, 2009 1MRS756504 B Slide 1 Contents RED615 Technical Presentation

More information

Jack Plates. Jack Plates & Accessories PREMIER. PT-625B1 Flush Jack. PREMIER PT-625B3 Flush Jack

Jack Plates. Jack Plates & Accessories PREMIER. PT-625B1 Flush Jack. PREMIER PT-625B3 Flush Jack Jack Plates PT-625B1 Flush Jack PT-625B1 Flush Jack Flush jack assembly is designed for flush mounting in a standard outlet box. It includes a 625F modular jack, 19A faceplate, 43A bracket, and mounting

More information

LON bus communication devices 1MRS MBG Page 1 Issued: April 1999 Status: New Data subject to change without notice

LON bus communication devices 1MRS MBG Page 1 Issued: April 1999 Status: New Data subject to change without notice LON bus communication devices Page 1 Issued: April 1999 Status: New Data subject to change without notice Features The LonWorks Network is an open system adapted for various application areas Peer-to-peer

More information

MODEL: R1M-P4. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)

MODEL: R1M-P4. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.) PC Recorders Series PC RECORDER (4 totalized counter inputs, 8 contact inputs and outputs) Functions & Features Industrial recorder on PC Totalized counter inputs Counts stored in E 2 PROM Easy system

More information

Accessory Guide Indoor AP Accessories

Accessory Guide Indoor AP Accessories Indoor AP Accessories INDOOR SKU Compatible Products Description Kit Contents 902-0120-0000 R720 R710 R700* R600* R610* R500* R510* R310 * fits AP, but does not support padlock security Multipurpose mounting

More information

INDUSTRIAL POE SWITCH

INDUSTRIAL POE SWITCH STEP X - Name of Step QUICK START GUIDE LIE1014A, LIE1080A, LIE1082A INDUSTRIAL POE SWITCH 24/7 TECHNICAL SUPPORT AT 877.877.2269 OR VISIT BLACKBOX.COM STEP 1 - Hardware Description LIE1014A LIE1080A TABLE

More information

Accessories / 7XV5461

Accessories / 7XV5461 Accessories / XV XV two-channel serial optical repeater (for mono-mode FO cable) Fig. / Optical repeater with integrated 0 nm/ nm wave length multiplexer for one single mono-mode FO-cable LSP.tif Function

More information

Mehta Tech, Inc. TRANSCAN IED For Multi-Function, Multi-Speed Recording

Mehta Tech, Inc. TRANSCAN IED For Multi-Function, Multi-Speed Recording Mehta Tech, Inc. TRANSCAN IED For Multi-Function, Multi-Speed Recording Two independent, simultaneously operating recorders in one package Triggering on input quantities and calculated values, such as

More information

TU531, TU532 Terminal Unit

TU531, TU532 Terminal Unit Ordering Data DATA SHEET TU531, TU532 Terminal Unit 1 Ordering Data Part No. Description Product Life Cycle Phase *) 1SAP 217 200 R0001 1SAP 217 000 R0001 1SAP 417 000 R0001 TU531, terminal unit, 230 VAC,

More information

PIX 535. PIX 535 Product Overview CHAPTER

PIX 535. PIX 535 Product Overview CHAPTER CHAPTER 7 PIX 535 This chapter describes the installation of the PIX 535, and includes the following sections: PIX 535 Product Overview Installing a PIX 535 PIX 535 Feature Licenses Installing Failover

More information

Accessory Guide ZoneFlex Indoor AP Accessories

Accessory Guide ZoneFlex Indoor AP Accessories ZoneFlex Indoor AP Accessories INDOOR SKU Compatible Products Description Kit Contents 902-0120-0000 ZoneFlex R720 ZoneFlex R710 ZoneFlex R700* ZoneFlex R600* ZoneFlex R610* ZoneFlex R500* ZoneFlex R510*

More information

CMU 100 Multimode Fiber Optic to Singlemode Fiber Optic Converter User Manual

CMU 100 Multimode Fiber Optic to Singlemode Fiber Optic Converter User Manual CMU 100 Multimode Fiber Optic to Singlemode Fiber Optic Converter User Manual CMU 100 / 1.6.S - 0 CMU 100 / 7.6.S - 0 Company: Device: Document: Code: Version: Date: Ediseja 21 CMU 100 / 1.6.S - 0 User

More information

Multi-Channel RS-232 Current Loop Interface Converter (CLIC)

Multi-Channel RS-232 Current Loop Interface Converter (CLIC) DECEMBER 1996 CL204A CL208A CL212A CL216A Multi-Channel RS-232 Current Loop Interface Converter (CLIC) CLIC 1/2A,SLO BLO,115VAC 1/4,SLO BLO,230VAC CUSTOMER SUPPORT INFORMATION Order toll-free in the U.S.:

More information

Secured Series: Hub Plus Kit Single Door Controller Package Installation Manual

Secured Series: Hub Plus Kit Single Door Controller Package Installation Manual Secured Series: Hub Plus Kit Single Door Controller Package Installation Manual This package is designed to simplify the connections to our Secured Series Hub Plus Controller. This will translate into

More information

High impedance protection relay

High impedance protection relay High impedance protection relay Page 1 Issued: April 1999 Status: New Data subject to change without notice Features High impedance type differential current earth-fault protection, so called restricted

More information

Remote RMM-1400 Intelligent Remote Site Management Device. Installation Guide

Remote RMM-1400 Intelligent Remote Site Management Device. Installation Guide Remote RMM-1400 Intelligent Remote Site Management Device Guide INSTALLATION GUIDE Westell Technologies Part # 030-300645 Rev. A Copyright 2015 by Westell Technologies. All Rights Reserved. Westell, Kentrox

More information

N-8000 SERIES IP INTERCOM SYSTEM

N-8000 SERIES IP INTERCOM SYSTEM N-8000 SERIES IP INTERCOM SYSTEM Cutting-edge TOA technology for greater versatility and improved sound quality IP Network-Compatible Intercom System with Packet Audio Technology The TOA N-8000 Packet

More information

2 Channel POTS DIN Fiber Link System

2 Channel POTS DIN Fiber Link System USER GUIDE The leader in rugged fiber optic technology. U-8 07A-040 Channel POTS DIN Fiber Link System SYSTEM INSTALLATION INFORMATION The RLH Channel Plain Old Telephone Service (POTS) DIN Fiber Link

More information

The PM1000 series is a universal 4 digit LED plug-on display for transmitters with 4-20mA 2 wire output and fitted with DIN43650 connector.

The PM1000 series is a universal 4 digit LED plug-on display for transmitters with 4-20mA 2 wire output and fitted with DIN43650 connector. PM1000 SERIES PLUG-ON DISPLAY BRIGHT LED DISPLAY INDICATION RANGE -999 TO +9999 FITS TO DIN 43650 CONNECTOR PLUG-ON TO ANY TRANSMITTER WITH 4-20MA OUTPUT EASY TO SCALE ON SITE ROBUST DESIGN SET POINT OPTION

More information

FiberLink 5002 Series

FiberLink 5002 Series MANUAL FiberLink 5002 Series RS-232 Digital Data Transmission System Installation and Operations Manual WWW.ARTEL.COM Contents Contents General Information... 3 Installation Guide... 4 Interface Connections...

More information

warning indication issued about 2 weeks before the battery charge becomes critical Real-time clock - with battery back-up Yes

warning indication issued about 2 weeks before the battery charge becomes critical Real-time clock - with battery back-up Yes System Freelance 800F AC 700F Module Description Data Sheet Central Processing Unit PM 783F Detailed data of the CPU (PM 783F) CPU Processor Program memory (Battery backed up) Internal memory Typical cycle

More information

P17 Tempra and Hypra Plugs and Sockets

P17 Tempra and Hypra Plugs and Sockets [ PLUGS AND SOCKETS ] Products and systems P17 Tempra and Hypra Plugs and Sockets For safe connection which you can depend on. Ensures the protection of personnel at electrical installation P17 Tempra

More information

Digital I/O Module. Impro (DIO) Digital I/O Module INSTALLATION MANUAL

Digital I/O Module. Impro (DIO) Digital I/O Module INSTALLATION MANUAL COMPONENT CODES: HMI700-1-0-NN-XX HMI701-1-0-NN-XX Digital I/O Module Impro (DIO) Digital I/O Module Specifications INSTALLATION MANUAL The DIO is a Cluster Expansion Module that works in conjunction with

More information

100% electricity. Automatic transfer switch controllers ATL series

100% electricity. Automatic transfer switch controllers ATL series 100% electricity Automatic transfer switch controllers ATL series Automatic transfer switch controllers Keep control around the clock General characteristics Rated auxiliary power supply: 220-230-240VAC

More information

SSV-T and SSC-T High Drop-out Relay. Range amps amps amps amps. Operating Frequency: Temperature Error:

SSV-T and SSC-T High Drop-out Relay. Range amps amps amps amps. Operating Frequency: Temperature Error: 41-766.7 SSV-T and SSC-T High Drop-out Relay device. A magnetic armature, to which leaf-spring mounted contacts are attached, is attracted to the magnetic core upon energization of the switch. When the

More information

Installing the Cisco AS5400XM Universal Gateway

Installing the Cisco AS5400XM Universal Gateway CHAPTER 3 Installing the Cisco AS5400XM Universal Gateway This chapter guides you through the installation of the Cisco AS5400XM universal gateway and includes the following sections: Setting Up the Chassis,

More information

Arc protection relay. Features Three-phase overcurrent function. Application

Arc protection relay. Features Three-phase overcurrent function. Application Arc protection relay REA 10_ Page 1 Issued: May 1999 Status: New Data subject to change without notice Features Three-phase overcurrent function Loop-type or radial sensor fibre for arc detection Two high-speed

More information

3500/22M Transient Data Interface Bently Nevada* Asset Condition Monitoring

3500/22M Transient Data Interface Bently Nevada* Asset Condition Monitoring 3500/22M Transient Data Interface Bently Nevada* Asset Condition Monitoring Description The 3500 Transient Data Interface (TDI) is the interface between the 3500 monitoring system and GE s System 1* machinery

More information

PRODIS -SSI Digital Process Meter for SSI position sensors. Instruction Manual. Please read carefully before installation and operation!

PRODIS -SSI Digital Process Meter for SSI position sensors. Instruction Manual. Please read carefully before installation and operation! Digital Process Meter for SSI position sensors Please read carefully before installation and operation! Contents Contents Specifications 2 Safety instructions 3 Description 4 Mechanical mounting 4 Operation

More information

TCP. Control and Protection Terminal Data sheet

TCP. Control and Protection Terminal Data sheet TCP Control and Protection Terminal Data sheet DSE_TCP_eng_AP No part of this publication may be reproduced by whatever means without the prior written permission of Ingeteam T&D. One of the main aims

More information

onlinecomponents.com

onlinecomponents.com Standard-type Connector- Conversion Units XWB CSM_XWB_DS_E Simplifies Connector and terminal block replacement, and requires less in-panel wiring. Mount to DIN Track or via screws. MIL Flat Cable Connectors

More information

USER MANUAL. MODEL 1000P Non-Powered Short Haul Modem. SALES OFFICE (301) TECHNICAL SUPPORT (301)

USER MANUAL. MODEL 1000P Non-Powered Short Haul Modem. SALES OFFICE (301) TECHNICAL SUPPORT (301) USER MANUAL MODEL 1000P Non-Powered Short Haul Modem C E R T I F I E D An ISO-9001 Certified Company Part #07M1000PA Doc. #022031UA Revised 2/17/98 SALES OFFICE (301) 975-1000 TECHNICAL SUPPORT (301) 975-1007

More information

PIX 515/515E. PIX 515/515E Product Overview CHAPTER

PIX 515/515E. PIX 515/515E Product Overview CHAPTER CHAPTER 4 PIX 515/515E This chapter describes how to install the PIX 515/515E, and includes the following sections: PIX 515/515E Product Overview Installing a PIX 515/515E PIX 515/515E Feature Licenses

More information

Quick Start Installation Guide

Quick Start Installation Guide apc/l Quick Start Installation Guide Version A2 Document Part Number UM-201 May 2010 OVERVIEW The apc/l is an intelligent access control and alarm monitoring control panel which serves as a basic building

More information

BreezeMAX Wi² and BreezeACCESS Wi² Quick Installation Guide

BreezeMAX Wi² and BreezeACCESS Wi² Quick Installation Guide This Quick Installation Guide is intended for experienced installers. For more information refer to the relevant sections in the BreezeMAX Wi² and BreezeACCESS Wi² System Manual. Wi² Package Content Check

More information

Serial Data DIN Fiber Link System

Serial Data DIN Fiber Link System USER GUIDE RLH Industries, Inc. The leader in rugged fiber optic technology. U-120 2017A-0420 DIN Fiber Link System COMPACT, RUGGED & TEMPERATURE HARDENED Introduction The DIN Fiber Link system transports

More information

Relay configuration and setting tool package

Relay configuration and setting tool package Issued: May 1999 Status: Updated Version: C/30.09.2002 Data subject to change without notice Features Function logic configuration tool according to IEC 61131-3 standard for ABB range of protection relays

More information

MULTIDYNE INNOVATIONS IN TELEVISION TESTING & DISTRIBUTION INSTRUCTION MANUAL FMX-125

MULTIDYNE INNOVATIONS IN TELEVISION TESTING & DISTRIBUTION INSTRUCTION MANUAL FMX-125 MULTIDYNE INNOVATIONS IN TELEVISION TESTING & DISTRIBUTION INSTRUCTION MANUAL FMX-125 FIBER OPTIC, BI-DIRECTIONAL DATA, CONTACT CLOSURE and AUDIO MULTIPLEXER SYSTEM Revision: 0, Date: October 28, 2013

More information

Contents Overview... 3 Features... 4 Applications... 4 Specifications... 5 Packing... 6 Appearance... 7 Front Panel... 7 Rear Panel...

Contents Overview... 3 Features... 4 Applications... 4 Specifications... 5 Packing... 6 Appearance... 7 Front Panel... 7 Rear Panel... User's Manual Contents Overview... 3 Features... 4 Applications... 4 Specifications... 5 Packing... 6 Appearance... 7 Front Panel... 7 Rear Panel... 8 Important Safety Instructions... 9 Installation...11

More information