Serial ATA International Organization
|
|
- Lee Lyons
- 6 years ago
- Views:
Transcription
1 Serial ATA International Organization Version 1.0RC 5-December 2006 Serial ATA Interoperability Program Revision 1.1 CabCon MOI for Cable Insertion & Removal Force Testing MCI-02, MCI-03 & MCI-04 This document is provided "AS IS" and without any warranty of any kind, including, without limitation, any express or implied warranty of non-infringement, merchantability or fitness for a particular purpose. In no event shall SATA-IO or any member of SATA-IO be liable for any direct, indirect, special, exemplary, punitive, or consequential damages, including, without limitation, lost profits, even if advised of the possibility of such damages. This material is provided for reference only. The Serial ATA International Organization does not endorse the vendor equipment outlined in this document.
2 TABLE OF CONTENTS TABLE OF CONTENTS... 2 MODIFICATION RECORD... 3 ACKNOWLEDGMENTS... 4 INTRODUCTION... 5 REFERENCES... 6 TEST TITLE:MCI-02 : INSTERTION FORCE (LATCHING AND NON-LATCHING) MCI-03 : REMOVAL FORCE (NON-LATCHING)... 7 TEST TITLE: MCI-04 : RETENTION FORCE (LATCHING)...11 Serial ATA Logo Group 2 SATA CabCon MOI
3 MODIFICATION RECORD Revision Date Comments /12/06 INITIAL DRAFT RELEASE /23/06 Modified to new format, a number of edits, and some additional tests (cable pullout) added /15/06 Minor editorial /05/06 Added MCI-01 Visual and Dimensional inspections and MCI-04 Removal Force (Latching) Modified insertion and remove force and Cable pull out test setup /28/06 Removed MCI-01 & MCI-05 Revised MCI-02 & MCI-03 test set up Revised MCI-04 Title, test set up & procedure /19/06 Revised MCI-02 & MCI-03 test set up Added possible problems section /15/06 Add version 0.96, Revision 1.1, and MCI-02/03 & 04 to title page Updated resource requirements for MCI-02/03, add reference figures 1-3 for clamps and nominal host plug gage Replaced DUT with PUT Rewrote test setup to reflect IW#2 Insertion/removal tester settings and PUT alignment. Replaced Insertion/Removal Plot with example from IW#2 Moved Possible problems section from end of document to end of MCI-02/03 Revised resource requirements for MCI-04, gage replaced with Vendor supplied plug connector. Revised test setup for Vendor supplied plug connector Added Possible problems section Added Appendix A Future Improvements 1.0RC 12/5/06 Release Candidate Serial ATA Logo Group 3 SATA CabCon MOI
4 ACKNOWLEDGMENTS The Serial ATA Logo Group would like to acknowledge the efforts of the following individuals in the development of this document: Eric Lee Silicon Image, Inc Steven Wong Comax Technology Inc Jerry D. Kachlic Molex Inc Oliver Lee Electronics Testing Center, Taiwan Sophia Liu Electronics Testing Center, Taiwan Serial ATA Logo Group 4 SATA CabCon MOI
5 INTRODUCTION The tests contained in this document are organized in order to simplify the identification of information related to a test, and to facilitate in the actual testing process. Tests are separated into groups, primarily in order to reduce setup time in the lab environment, however the different groups typically also tend to focus on specific aspects of device functionality. The test definitions themselves are intended to provide a high-level description of the motivation, resources, procedures, and methodologies specific to each test. Formally, each test description contains the following sections: Purpose The purpose is a brief statement outlining what the test attempts to achieve. The test is written at the functional level. References This section specifies all reference material external to the test suite, including the specific subclauses references for the test in question, and any other references that might be helpful in understanding the test methodology and/or test results. External sources are always referenced by a bracketed number (e.g., [1]) when mentioned in the test description. Any other references in the test description that are not indicated in this manner refer to elements within the test suite document itself (e.g., Appendix 6.A, or Table ) Resource Requirements The requirements section specifies the test hardware and/or software needed to perform the test. This is generally expressed in terms of minimum requirements, however in some cases specific equipment manufacturer/model information may be provided. Last Modification This specifies the date of the last modification to this test. Discussion The discussion covers the assumptions made in the design or implementation of the test, as well as known limitations. Other items specific to the test are covered here as well. Test Setup The setup section describes the initial configuration of the test environment. Small changes in the configuration should not be included here, and are generally covered in the test procedure section (next). Procedure The procedure section of the test description contains the systematic instructions for carrying out the test. It provides a cookbook approach to testing, and may be interspersed with observable results. Observable Results This section lists the specific observables that can be examined by the tester in order to verify that the PUT is operating properly. When multiple values for an observable are possible, this section provides a short discussion on how to interpret them. The determination of a pass or fail outcome for a particular test is generally based on the successful (or unsuccessful) detection of a specific observable. Possible Problems This section contains a description of known issues with the test procedure, which may affect test results in certain situations. It may also refer the reader to test suite appendices and/or other external sources that may provide more detail regarding these issues. Serial ATA Logo Group 5 SATA CabCon MOI
6 REFERENCES The following documents are referenced in this text: [1] Serial ATA Revision 2.5, section , Table 5 [2] Serial ATA Interoperability Program Unified Test Document, Revision 1.0, Section 2.6.2, Section and Section [3] Serial ATA Interoperability Program Policy Document, Revision 1.0 [4] Instron In-Spec 2200 Portable Benchtop Tester user manual [5] EIA Visual and Dimensional Inspection [6] EIA Mating and Unmating Force Test Procedure for Electrical Connectors Serial ATA Logo Group 6 SATA CabCon MOI
7 Test Title:MCI-02: Insertion Force (Latching and Non-Latching) MCI-03: Retention Force (Non-Latching) Purpose: This test verifies that the Latching and Non-Latching cable do not exceed the maximum allowable insertion force and the Non-Latching cable meets the minimum required removal force. References: See main reference section Resource Requirements: Insertion/Removal force tester (Instron In-Spec 2200 Portable Benchtop Tester and In-Spec 2200 software, version 4.0 or last ) Cable Clamp Adaptor Reference Figure 1, SV-200LD-2 or equivalent Gage Clamp - Reference Figure 2, SV-200LD-1 or equivalent SATA nominal host plug Reference Figure 3, H3SATA , Rev. X1 or equivalent SD memory card for storing files Computer with SD memory card reader, Instron In-Spec 2200 File Converter Microsoft Excel or similar software. Last Modification: November 15, 2006 Discussion: Reference [2] specifies the number of cycles to be tested when performing the tests specified in reference [1]. Test Setup: The Cable Clamp Adaptor shall be attached to the end of the upper arm of the Insertion/Removal force tester. It is not necessary to tighten firmly. A small amount of side movement will not affect the measurements and will help the PUT to self align. Attach Gage Clamp to base of the Insertion/removal force tester. It is not necessary to tighten firmly. A small amount of side movement will not affect the measurements and will help the PUT to self align. Figure 1 - Cable Clamp Figure 2 - Gage Clamp Serial ATA Logo Group 7 SATA CabCon MOI
8 Test Procedure: Use this picture with the instructions below To configure the Instron In-Spec 2200 Portable Benchtop Tester, perform the following steps: Power on the tester, and wait for it to finish initialization. Go to the home screen of the controller (Sony Clie). Select "All" to view all the programs. Double click on the Instron program to start the program. Configure the software with the following settings: o PREFERENCES menu (click on the In-Spec in the upper left of the screen, then choose the Options menu, and choose Preferences to see this menu ) Time= minutes Extension = mm Load = Newtons Memory Stick Archive = ON Click on the Done button o Press the Control button (lower left of the screen) to configure the following settings: 12.5 mm/minute Preload = off Chan: = Ext Value = 5 mm Action = Reverse Set the number of cycles as specified for this test. AutoSave = on FileName = use the PUT s ID number, along with the run number (i.e. if the same PUT is retested later the run number would be incremented). An example is 00C_001_01. Click the Apply button to save the settings and then click the OK button. Serial ATA Logo Group 8 SATA CabCon MOI
9 o Press the Scale button to configure the following plot settings:: Horizontal scale = Extension 6 mm -1 mm Divs = 1 Vertical scale = Load +25 N -25 N Divs = 1 Select OK. o Align the PUT with the SATA nominal host plug. Mount the SATA Nominal Host Plug into the Gage Clamp centered below the Insertion/Removal force tester. Tighten the clamp to secure gage. Fully mate the PUT onto the SATA Nominal Host Plug. Use the up and down arrows at the top of the Instron In-Spec 2200 Portable Benchtop Tester to manually lower the Cable Clamp Adaptor into clamping position with the PUT and tighten the clamp. Use the up and down arrows at the top of the Instron In-Spec 2200 Portable Benchtop Tester to manually raise the PUT up 5 mm Reset the compression to zero for start point of the compression cycle. Balance the load cell configuration as follows: Press the bal button, to make the Load=0 N to balance the load cell (the bal button near the upper right of the screen) o In the upper right of the screen check it is set to Compression, so it will insert the connector when it starts. Then, press the button at the top of the Instron In-Spec 2200 Portable Benchtop Tester to begin the measurement. Wait for the measurement to finish (~40 seconds per cycle). Wait for the measurement to finish writing to the memory stick, and doing calculations. Then, to view the results: o Remove the SD memory card from the Instron tester and move the data file to a PC (Note: the card can simply be removed from the Instron while it is running (as long as it has finished writing to the file), it does not need to be shut off). o Use the Instron In-Spec 2200 File Converter (which may be called Handheld.exe ) to convert the *.pdb file into a.csv (text) file. Use the Time, Extension, Load option Use the Save As button to save the file with the same name, but a.csv file extension. o Open the file in Excel by double clicking on it (assuming Excel is configured to open *.csv files). o o Select all of the Extension and Load data with the following method: Select cells B3 and C3 Press Ctrl-Shift-Down_Arrow to select all the data below these cells. o Create a plot Click on the Chart Wizard button Select XY (Scatter) and the lower right Chart sub-type (data points connected by lines without markers). Select Finish to create the plot. Serial ATA Logo Group 9 SATA CabCon MOI
10 o Inspect the plot to locate the maximum insertion force, and minimum removal force and note it on the results form. NOTE: by holding the cursor over the plot Excel will display the force value associated with that point. For better accuracy it is recommended to zoom in on the chart to find the exact value. NOTE: the curve data between maximum insertion and minimum removal force can be ignored (this data is a result of sliding friction between the PUT and SATA nominal host plug ) Pass/Fail Criteria MCI-02 : Insertion Force (Latching and Non-Latching):45N max. MCI-03 : Removal Force (Non-Latching):10N min. through 20 cycles Typical Insertion/Removal Plot Newtons millimeters -25 Minimum removal force (NOTE: this is the max point of the INNERMOST curve. Maximum insertion force Possible Problems o Due to issues with the current SATA Nominal Host Plug, it is very difficult to align the PUT and set up the test travel without starting the test in the fully mated condition. This alignment method means that the 1 st insertion force is not captured. o The 1 st insertion force for the signal cable receptacle has not been seen as critical and the 2 nd insertion forces recorded have been well below the maximum. Serial ATA Logo Group 10 SATA CabCon MOI
11 Test Title: MCI-04 : Retention Force (Latching) Purpose: This test verifies that the latching cable meets the minimum retention force of the specification. References: See main reference section Resource Requirements: Cable Clamp Adaptor Reference Figure 1, SV-200LD-02 or equivalent Vendor supplied Latching plug connector Mass weight, 25N metal block Last Modification: November 15, 2006 Test Setup: o Place the Vendor supplied Latching plug connector into the Cable Clamp Adaptor o Mate PUT from MCI 02 to Vendor supplied Latching plug connector o Attach Mass Weight, 25N Metal Block onto cable (Note, cable should not be subjected to any bends below 25mm radius and care shall be used to avoid any kinks in the cable due to the test weight attachment) Test Procedure: o Suspend Mass Weight, 25N Metal Block freely in air from PUT for one minute minimum. Observable Results: o PUT is expected to support the Mass Weight. o PUT can be easily removed (un-latched) after test. Pass/Fail Criteria o No damage and no unintentional disconnect Possible problems o In the event of a test failure, it is difficult to determine which component is at fault. Replace the Vendor supplied Latching plug connector with an unused part and repeat the test procedure. Appendix A Areas for future improvement PUT Alignment o Improve alignment to capture 1 st insertion o Improvement of the Nominal Host Plug Gage Remove sharp edges on lead in chamfers to reduce wear Minimize insertion depth to reduce cycle time Guarantee there is full engagement of bump and recess without hard interference to gage Add latching wall to capture maximum insertion force of latching connector Latching test gage o Need Nominal Plug Gage for MCI-04 (Latching) Serial ATA Logo Group 11 SATA CabCon MOI
12 SATA Nominal Host Plug Figure 3 - H3SATA , Rev. x1 Serial ATA Logo Group 12 SATA CabCon MOI
13 Serial ATA Logo Group 13 SATA CabCon MOI
UNH IOL SERIAL ATTACHED SCSI (SAS) CONSORTIUM
UNH IOL SERIAL ATTACHED SCSI (SAS) CONSORTIUM SAS 3.0 Receiver Physical Layer Test Suite Version 1.00 Technical Document Last Updated: September 29, 2014 UNH IOL SAS Consortium 121 Technology Drive, Suite
More informationUNH-IOL PCIe CONSORTIUM
UNH-IOL PCIe CONSORTIUM PCIe Interoperability Test Suite v1.0 Technical Document Last Updated: September 26, 2013 2013 University of New Hampshire InterOperability Laboratory UNH IOL PCIe Consortium 121
More informationUNH IOL iscsi CONSORTIUM
UNH IOL iscsi CONSORTIUM Interoperability Test Suite Version 1.0 Technical Document Last Updated December 1, 2005 2005 University of New Hampshire UNH-IOL iscsi Consortium 121 Technology Drive, Suite 2
More informationSerial ATA International Organization
Serial ATA International Organization Revision 1.0 27 July 2006 Serial ATA Interoperability Program Digital MOI for LeCroy SATracer Bus Analyzer This document is provided "AS IS" and without any warranty
More informationUNH IOL iscsi CONSORTIUM
UNH IOL iscsi CONSORTIUM Interoperability Test Suite Version 1.2 Technical Document Last Updated January 4, 2007 2006 University of New Hampshire UNH-IOL iscsi Consortium 121 Technology Drive, Suite 2
More information40 AND 100 GIGABIT ETHERNET TESTING SERVICE
40 AND 100 GIGABIT ETHERNET TESTING SERVICE Clause 95 100GBASE-SR4 PMD Test Plan Version 1.1 Technical Document Last Updated: January 23, 2018 40 and 100 Gigabit Ethernet Testing Service 21 Madbury Road,
More informationProject Olympus Chassis Mechanical Specification
Project Olympus Chassis Mechanical Specification Author: Larry Cannon, Senior Mechanical Engineer, Microsoft Revision History Date Description 03/01/2017 Version 0.7 11/01/2017 Version 1.0 Release to
More informationSERIAL ATTACHED SCSI (SAS) CONSORTIUM
SERIAL ATTACHED SCSI (SAS) CONSORTIUM Clause 6 SAS SPL Link Layer Test Suite Version 1.3 Technical Document Last Updated: 6 September 2011 Serial Attached SCSI Consortium 121 Technology Drive, Suite 2
More informationUNH-IOL iscsi CONSORTIUM
UNH-IOL iscsi CONSORTIUM isns Interoperability Test Suite Version 1.0 Technical Document Last Updated: July 21, 2008 iscsi Consortium 121 Technology Drive, Suite 2 Durham, NH 03824 University of New Hampshire
More informationSERIAL ATTACHED SCSI (SAS) CONSORTIUM
SERIAL ATTACHED SCSI (SAS) CONSORTIUM Clause 8 SAS SPL Target Error Handling Test Suite Version0.3 Technical Document Last Updated: 6 September 2011 Serial Attached SCSI Consortium 121 Technology Drive,
More informationSerial ATA International Organization
Serial ATA International Organization Version: 1.0RC 1-Febuarary 2007 Serial ATA Interoperability Program Revision 1.1 Agilent Technologies, Inc. Method of Implementation (MOI) Document for SATA PHY, TSG
More informationSerial ATA Interoperability Program Revision 1.4 JDSU MOI for Device Digital Tests (ASR, GTR, NCQ, SSP, IPM and DOF)
15 October 2009 Version 1.00 Serial ATA Interoperability Program Revision 1.4 JDSU MOI for Device Digital Tests (ASR, GTR, NCQ, SSP, IPM and DOF) This document is provided "AS IS" and without any warranty
More informationAUTOMOTIVE ETHERNET CONSORTIUM
AUTOMOTIVE ETHERNET CONSORTIUM Clause 96 100BASE-T1 PHY Control Test Suite Version 1.0 Technical Document Last Updated: March 9, 2016 Automotive Ethernet Consortium 21 Madbury Rd, Suite 100 Durham, NH
More informationInfiniBand Trade Association
InfiniBand Trade Association Revision 1.06 4/11/2017 IBTA VNA MOI for FDR and EDR Cable Tests This material is provided for reference only. The InfiniBand Trade Association does not endorse the vendors
More informationUNH IOL iscsi CONSORTIUM
UNH IOL iscsi CONSORTIUM CHAP Test Suite for iscsi Initiators Version 3.1 Technical Document Last Updated May 17, 2016 2015 University of New Hampshire InterOperability Laboratory UNH-IOL iscsi Consortium
More informationFibre Channel Consortium
Fibre Channel Consortium FC-PI-5 Clause 5 Bit Error Rate Test Suite Version 1.0 Technical Document Last Updated: September 30, 2014 Fibre Channel Consortium 121 Technology Drive, Suite 2 Durham, NH 03824
More informationUNH-IOL. FC-1 Conformance Test Suite Version 4.3. Technical Document. Last Updated: February 23, 2008
UNH-IOL FIBRE CHANNEL CONSORTIUM FC-1 Conformance Test Suite Version 4.3 Technical Document Last Updated: February 23, 2008 Fibre Channel Consortium 121 Technology Drive, Suite 2 InterOperability Laboratory
More informationTrayless SATA Drive Bay 5.25" Trayless SATA Hot Swap Drive Bay
Trayless SATA Drive Bay 5.25" Trayless SATA Hot Swap Drive Bay HSB100SATBK Actual product may vary from photo FCC Compliance Statement This equipment has been tested and found to comply with the limits
More informationmicro QUAD SMALL FORM-FACTOR PLUGGABLE FOUR CHANNEL PLUGGABLE TRANSCEIVER, HOST CONNECTOR, & CAGE ASSEMBLY FORM FACTOR
1 2 3 4 5 6 7 8 9 10 11 microqsfp Draft Mechanical Specification Rev 1.0 Draft Mechanical Specification for micro QUAD SMALL FORM-FACTOR PLUGGABLE FOUR CHANNEL PLUGGABLE TRANSCEIVER, HOST CONNECTOR, &
More informationSerial ATA International Organization
SyntheSys Research, Inc. Serial ATA International Organization Version 1.0 June 4, 2009 Serial ATA Interoperability Program Revision 1.4 SyntheSys Research, Inc. MOI for RSG Tests (using BERTScope 7500B
More informationUNH-IOL NVMe Test Consortium
UNH-IOL NVMe Test Consortium Test Suite for NVMe Interoperability Version 1.2 Technical Document NOTICE: This is a living document. All contents are subject to change. Individual tests and/or test groups
More informationTeledyne LeCroy. Teledyne LeCroy MOI for DisplayPort PHY CTS 1.2b Source Testing
Teledyne LeCroy DisplayPort Standard April, 2016 Teledyne LeCroy MOI for DisplayPort PHY CTS 1.2b Source Testing This document is provided "AS IS" and without any warranty of any kind, including, without
More informationInfiniBand Trade Association
InfiniBand Trade Association Revision 1.02 4/11/2017 IBTA 32 Port VNA MOI for FDR and EDR Cable Tests This material is provided for reference only. The InfiniBand Trade Association does not endorse the
More informationTABLE OF CONTENTS SECTION 1 TABLETOP CONFIGURATION SECTION 2 TABLETOP CONFIGURATION ACCESSORIES SECTION 3 SLIDE CONFIGURATION
S6 USER S MANUAL TABLE OF CONTENTS SECTION 1 TABLETOP CONFIGURATION SECTION 2 TABLETOP CONFIGURATION ACCESSORIES SECTION 3 SLIDE CONFIGURATION SECTION 4 SLIDE CONFIGURATION ACCESSORIES SECTION 5 RACK MOUNT
More informationG12/G12x USER S MANUAL
G12/G12x USER S MANUAL TABLE OF CONTENTS SECTION 1 SLIDE CONFIGURATION SECTION 2 SLIDE CONFIGURATION ACCESSORIES SECTION 3 TABLETOP CONFIGURATION SECTION 4 TABLETOP CONFIGURATION ACCESSORIES SECTION 5
More informationSerial ATA International Organization
SyntheSys Research, Inc. Serial ATA International Organization Version 1.0 July 26, 2007 Serial ATA Interoperability Program Revision 1.1 SyntheSys Research, Inc. MOI, Method of Implementation, for PHY
More informationDevelopment SFF-TA-1007 Rev SFF specifications are available at SFF-TA-1007.
SFF specifications are available at http://www.snia.org/sff/specifications SFF-TA-1007 Specification for Rev 0.0.1 December 19, 2017 Secretariat: SFF TA TWG Abstract: This specification defines the mechanical
More informationSerial ATA International Organization
Serial ATA International Organization Revision 1.00RC2 22-June 2006 Serial ATA Interoperability Program Agilent Technologies, Inc. Method of Implementation (MOI) Document for SATA PHY, TSG & OOB Measurements
More information5.25in Trayless Hot Swap Mobile Rack for 3.5in Hard Drive HSB100SATBK
5.25in Trayless Hot Swap Mobile Rack for 3.5in Hard Drive HSB100SATBK *actual product may vary from photos DE: Bedienungsanleitung - de.startech.com FR: Guide de l'utilisateur - fr.startech.com ES: Guía
More informationInfoSafe Mobile Drive Enclosure
InfoSafe Mobile Drive Enclosure External USB 2.0 3.5 Hard Drive Enclosure with Active Cooling IDECASE35U2 Instruction Manual Actual product may vary from photo Use of Trademarks, Registered Trademarks,
More informationSerial ATA International Organization
SyntheSys Research, Inc. Serial ATA International Organization Version 1.0 June 3, 2010 Serial ATA Interoperability Program Revision 1.3 SyntheSys Research, Inc. MOI for PHY, TSG & OOB Tests (using BERTScope
More informationUser Manual for the SDAH01 Evaluation Kit for the HS3001 Humidity and Temperature Sensor. Description. Features. Kit Contents. SDAH01 Evaluation Kit
User Manual for the SDAH01 Evaluation Kit for the HS3001 Humidity and Temperature Sensor Description The SDAH01 Evaluation Kit is used to assess the HS3001 High- Performance Relative Humidity and Temperature
More informationAmphenol Amphenol Taiwan Corporation Sheet 1 of 9
Amphenol Amphenol Taiwan Corporation Sheet 1 of 9 Title: Part Number: Description: MINI SAS Connectors Product Specification G40 Series 0.80mm Pitch, Cable End and Board Mount Revisions Control Rev. ECN
More informationHANDYLINK APPLICATION SPECIFICATION
HANDYLINK I/O CONNECTORS 44828 SMT Receptacle 45560 SMT Cradle Connector Connector 45339 and 45593 Plug Connector Modules A1 HANDYLINK I/O CONNECTOR SYSTEM 2 of 26 Table of Contents Section Page Section
More informationUpgrading and Servicing Guide
Upgrading and Servicing Guide The information in this document is subject to change without notice. Hewlett-Packard Company makes no warranty of any kind with regard to this material, including, but not
More informationBroadband Automatic Disconnect Switch. User Manual
Reset/Test Primary/ Primary Broadband Automatic Disconnect Switch User Manual Local Power Remote Pwer Local 63V Fault Secondary Select Secondary 220V Normal 990-1929 09/2004 Introduction Introduction
More informationAccepted by EIA SFF-8348 Rev 1.0. SFF Committee SFF Specification for. 3.5" Form Factor w/combo Connector inc USB Micro-B Receptacle
SFF Committee SFF-8348 Specification for 3.5" Form Factor w/combo Connector inc USB Micro-B Receptacle The 3.5" specifications were Standardized as EIA-740 1999/07 Subsequent to that date, this specification
More informationApplication Specification IMPACT* Standard Connector Systems 05 NOV 10 Rev A
Application Specification IMPACT* Standard 114-13258 Connector Systems 05 NOV 10 Rev A NOTE i All numerical values are in metric units [with U.S. customary units in brackets]. Dimensions are in millimeters.
More informationEthernet. Clause 40 Auto-Crossover Test Suite v1.6. Technical Document. Last Updated: December 22, 2005, 11:07 a.m.
Ethernet Clause 40 Auto-Crossover Test Suite v1.6 Technical Document Last Updated: December 22, 2005, 11:07 a.m. Ethernet Consortium 121 Technology Drive, Suite 2 Durham, NH 03824 Research Computing Center
More informationUM NXP USB PD shield board user manual COMPANY PUBLIC. Document information
Rev. 0.3 19 June 2017 User manual COMPANY PUBLIC Document information Information Content Keywords Abstract OM13588, USB Type-C, PD (power delivery), Alt-mode-DP, Host, Dock This user manual presents demonstration
More informationReplacing a PCIe card
AFF A800 systems Replacing a PCIe card To replace a PCIe card, you must disconnect the cables from the cards, remove the SFP and QSFP modules from the cards before removing the riser, reinstall the riser,
More information10 Slim Digital Photo Frame Instructional Manual
10 Slim Digital Photo Frame Instructional Manual aluratek.com mnl M10447 model ASGK410B Copyright 2017 Aluratek, Inc. All Rights Reserved. Table of Contents Frame Features... Frame Control Close-up...
More informationUser Manual CL
User Manual CL-1200 Warning! This is a class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures. This equipment
More informationUpgrading and Servicing Guide
Upgrading and Servicing Guide The information in this document is subject to change without notice. Hewlett-Packard Company makes no warranty of any kind with regard to this material, including, but not
More informationAddonics T E C H N O L O G I E S
Addonics T E C H N O L O G I E S Jupiter Mobile Rack Model: AJMRI, AJMRSA User s Guide Version 1.0 FCC Warning Statement This equipment has been tested and found to comply with the limits for a class B
More informationEnterprise and Datacenter. SSD Form Factor. 1U Long Specification
Enterprise and Datacenter SSD Form Factor 1U Long Specification Revision 0.9 Draft November 9, 2017 Enterprise and Datacenter SSD Form Factor Working Group Please send comments to Anthony Constantine anthony.m.constantine@intel.com
More informationSFF specifications are available at SFF-TA Specification for
SFF specifications are available at http://www.snia.org/sff/specifications SFF-TA-1006 Specification for Rev 0.0.1 December 11, 2017 Secretariat: SFF TA TWG Abstract: This specification defines the mechanical
More informationPDS: Rev :A STATUS:Released Printed: Jan 04, 2012
of 2 A.0 Objective This specification defines the performance, test, quality and reliability requirements of the USB3.0 Standard- A Receptacle. 2.0 Scope This specification is applicable to the termination
More informationInstallation Note. Source Attenuators and Bias Tees Upgrade Kit. For E8362B/C PNA Series Microwave Network Analyzers. Network Analyzer Model Number
Installation Note Source Attenuators and Bias Tees Upgrade Kit For E8362B/C PNA Series Microwave Network Analyzers Network Analyzer Model Number Upgrade Kit Part Number E8362B/C E8362-60115 Agilent Part
More informationWireless LAN Consortium
Wireless LAN Consortium 802.11a/b/g/n/ac Rate vs. Range Test Suite Version 1.0 Technical Document Last Updated: November 13, 2014 Wireless LAN Consortium 121 Technology Drive, Suite 2 InterOperability
More informationGIGABIT ETHERNET CONSORTIUM
GIGABIT ETHERNET CONSORTIUM Clause 38 Optical PMD Test Suite Version 0.7 Technical Document Last Updated: August 19, 2008 11:30 AM Gigabit Ethernet Consortium 121 Technology Drive, Suite 2 Durham, NH 03824
More informationFiber Management Tray (FMT) User Manual
Fiber Management Tray (FMT) User Manual Fiber Management Tray Content Page INTRODUCTION............................................................................. 2 ADMONISHMENTS...........................................................................
More informationPCI Express Signal Quality Test Methodology
PCI Express Signal Quality Test Methodology Users Guide LeCroy SDA 6000 October 2003 Revision 0.7 Document Number: XXXX DISCLAIMER OF WARRANTIES THIS SPECIFICATION IS PROVIDED AS IS AND WITH NO WARRANTIES
More informationInstallation and Configuration Guide for Visual Voic Release 8.5
Installation and Configuration Guide for Visual Voicemail Release 8.5 Revised October 08, 2012 Americas Headquarters Cisco Systems, Inc. 170 West Tasman Drive San Jose, CA 95134-1706 USA http://www.cisco.com
More informationSerial ATA Hot Swap Drive Cage Upgrade Kit for: Intel Server Chassis SC5200 Intel Server Chassis SC5250-E
Serial ATA Hot Swap Drive Cage Upgrade Kit for: Intel Server Chassis SC5200 Intel Server Chassis SC5250-E A Guide for Technically Qualified Assemblers of Intel Identified Subassemblies/Products Order Number:
More informationHigh Speed Remote I/O Module
High Speed Remote I/O Module EXF-RC15 The Unitronics EXF-RC15 is a High Speed Remote I/O Module that offers three High Speed Counter inputs and four high speed outputs. Overall, the EXF-RC15 offers 9 digital
More informationReplacing a PCIe card
AFF A700s systems Replacing a PCIe card To replace a PCIe card, you must disconnect the cables from the cards in the riser, remove the riser, replace the riser, and then recable the cards in that riser.
More informationFlexible Mini PCI to PCI Bus Adapter
About this Document Flexible Mini PCI to PCI Bus Adapter Hardware Manual June 01, 2011 Revision 1.1 Page 1 About this Document Contents 1 About this Document... 4 1.1 Purpose... 4 1.2 Feedback... 4 1.3
More informationUniversity of New Hampshire InterOperability Laboratory Ethernet in the First Mile Consortium
University of New Hampshire InterOperability Laboratory As of July 26, 2004 the Ethernet in the First Mile Clause 57 OAM Conformance Test Suite version 0.4 has been superseded by the release of the Clause
More informationAddonics T E C H N O L O G I E S
Addonics T E C H N O L O G I E S Jupiter Cipher Mobile Rack For the following models: JCMRI64, JCMRI128 User s Guide Version 1.0 FCC Warning Statement This equipment has been tested and found to comply
More informationEquipment Operating Procedure. Model Number: Dage-Series-4000PA Machine Name: Shear Tester Date: 8/17/2013 Serial Number:
Equipment Operating Procedure Manufacturer: Dage Precision Location: PRC Assembly Laboratory Industries Model Number: Dage-Series-4000PA Machine Name: Shear Tester Date: 8/17/2013 Serial Number: 1922708
More informationWLAN The Wireless Local Area Network Consortium
WLAN The Wireless Local Area Network Consortium WPA Station MAC Layer Test Suite Version 2.5 Technical Document Last Updated: February 18, 2013 Wireless LAN Consortium 121 Technology Drive, Suite 2 Durham,
More informationATX12V 2.2 Power Supply for HP & Compaq Systems
ATX12V 2.2 Power Supply for HP & Compaq Systems 350 Watt ATX12V 2.2 Power Supply 400 Watt ATX12V 2.2 Power Supply ATXPW350HPCQ ATXPW400HPCQ Actual product may vary from photo FCC Compliance Statement This
More informationAPPLICATION NOTE. 3-lead CONTACT Package Usage. ATSHA204A, ATECC108A, and ATECC508A. Introduction. 3-lead CONTACT Package
APPLICATION NOTE 3-lead CONTACT Package Usage ATSHA204A, ATECC108A, and ATECC508A Introduction The Atmel CryptoAuthentication devices are often used in product accessory or product ecosystem management.
More informationCisco TelePresence Microsoft Lync 2010, Cisco VCS and Cisco AM GW
Cisco TelePresence Microsoft Lync 2010, Cisco VCS and Cisco AM GW Deployment Guide Cisco VCS X8.2 Microsoft Lync 2010 Cisco AM GW 1.1 D14652.09 June 2014 Contents Introduction 4 Prerequisites to setting
More informationEthernet. MDIO Auto-Negotiation Registers Test Suite For Twisted-Pair PHYs V1.0. Technical Document. Last Updated: Thursday March 19, :21 AM
Ethernet MDIO Auto-Negotiation Registers Test Suite V1.0 Technical Document Last Updated: Thursday March 19, 2015 10:21 AM University of New Hampshire 121 Technology Drive, Suite 2 Durham, NH 03824 10
More informationDesk Mount Articulating Dual Monitor Arm with Cable Management & Height Adjust
Desk Mount Articulating Dual Monitor Arm with Cable Management & Height Adjust ARMDUAL *actual product may vary from photos DE: Bedienungsanleitung - de.startech.com FR: Guide de l'utilisateur - fr.startech.com
More informationOracle <Insert Picture Here>
Slide 1 Oracle Slide 2 WZT-6509 version B Sun Fire Nehalem and Westmere Rack-Mount Server Installation and Replacement Welcome to the installation and replacement
More informationPADS2007. Alphanumeric Pins Transition Guide Mentor Graphics Corporation All Rights Reserved.
PADS2007 Alphanumeric Pins Transition Guide 2007 Mentor Graphics Corporation All Rights Reserved. This document contains information that is proprietary to Mentor Graphics Corporation. The original recipient
More informationVertiv Local Rack Access 18.5" LED LCD Console
Vertiv Local Rack Access 18.5" LED LCD Console With Integrated Keyboard, Touchpad and Dual USB 2.0 Ports Installer/User Guide Technical Support Site If you encounter any installation or operational issues
More informationCisco TelePresence TelePresence Server MSE 8710
Cisco TelePresence TelePresence Server MSE 8710 Installation Guide 61-0025-05 August 2013 Contents General information 3 About the Cisco TelePresence Server MSE 8710 3 Port and LED locations 3 LED behavior
More informationAddonics T E C H N O L O G I E S
Addonics T E C H N O L O G I E S Jupiter Combo Hard Drive For the following models: AJCHDIU, AJCHDIF, AJCHDIS AJCHDSAU, AJCHDSAF, AJCHDSAS User s Guide Version 1.0 FCC Warning Statement This equipment
More informationSystem Specification Version 3.31 MMCA Technical Committee
The MultiMediaCard System Specification Version 3.31 MMCA Technical Committee Revision History Version Date Section/ Page Changes compared to previous issue 1.0 09-09-96 all Initial version of system specification
More informationZonit μats TM Users Guide μats1-lv Version 1.2
Zonit μats TM Users Guide μats1-lv Version 1.2 Table of Contents Product Overview...2 Pre-Installation Considerations...2 Product Features...3 Installation...4 Optional Accessories...4 μats TM Operational
More informationPneumatic and Electric 2705 Commerce Pkwy., Auburn Hills, Michigan Ph: (248)
Pneumatic and Electric Control Handles Index Introduction Overview...1 Control Handle Series Control Handle Series.... Servo Controls... Trigger Controls Series................... Balancer Controls...
More informationPRODUCT SPECIFCATION GS MINI-SAS HD External Cable to Board Connector System. 1 of 14 F. Roger Cheng TYPE NUMBER
1 of 14 F TABLE OF CONTENTS 1.0 OBJECTIVE... 3 2.0 SCOPE... 3 3.0 APPLICABLE DOCUMENTS... 3 3.1 FCI SPECIFICATIONS... 3 3.2 OTHER STANDARDS AND SPECIFICATIONS... 3 3.3 FCI PRODUCT QUALIFICATION TEST REPORTS...
More information14 Digital Photo Frame Instructional Manual
14 Digital Photo Frame Instructional Manual aluratek.com mnl M10423 model ADMPF214B Copyright 2017 Aluratek, Inc. All Rights Reserved. Table of Contents Frame Features... Frame Control Close-up... Remote
More informationUSB 3.0 to SATA III 2.5 SDD/HDD Adapter Cable
USB 3.0 to SATA III 2.5 SDD/HDD Adapter Cable Model 202041 User Manual Table of Contents 1. INTRODUCTION... 1 1.1 Introduction 1.2 Copyright and Trademarks 1.3 FCC Compliance Statement 2. PRODUCT OVERVIEW
More informationWhen any of the following symbols appear, read the associated information carefully. Symbol Meaning Description
Vision OPLC V350-35-R34/V350-J-R34 Installation Guide The Unitronics V350-35-R34/V350-J-R34 offers the following onboard I/Os: 22 Digital Inputs, configurable via wiring to include 2 Analog and 3 HSC/Shaft-encoder
More informationIndustrial Rack-mount LCD KVM Drawer. User Manual. 8 -Port KVM Drawer 16-Port KVM Drawer
Industrial Rack-mount LCD KVM Drawer User Manual 8 -Port KVM Drawer 16-Port KVM Drawer TABLE OF CONTENTS 4 Packing Contents 4 Safety Instructions 6 Introduction 6 Feature 8 Specification 10 Panel Description
More informationUniversity of New Hampshire InterOperability Laboratory Ethernet Consortium
University of New Hampshire Ethernet Consortium As of July 2 nd, 2001 the Ethernet Consortium Clause # 28 Auto Negotiation State Machine Base Page Exchange Conformance Test Suite version 4.0.3 has been
More informationIntel Unite Plugin Guide for VDO360 Clearwater
Intel Unite Plugin Guide for VDO360 Clearwater INSTALLATION AND USER GUIDE Version 1.2 December 2017 Legal Disclaimers & Copyrights All information provided here is subject to change without notice. Contact
More informationzqsfp+stacked Connector and Cage Assembly
Product Specification 108-60102 May 27, 2015 Rev A1 zqsfp+stacked Connector and Cage Assembly 1. SCOPE 1.1. Content This specification defines performance, test and quality requirements for the zqsfp+stacked
More informationPCI Express x16 Graphics 150W-ATX Specification Revision 1.0
PCI Express x16 Graphics 150W-ATX Specification Revision 1.0 October 25, 2004 Revision Revision History Date 1.0 Initial release. 10/25/04 PCI-SIG disclaims all warranties and liability for the use of
More information31.2 EPD Display with LVDS system Board
31.2 EPD Display with LVDS system Board Table of Contents 1 Introduction... 1 (1) PACKAGE CONTENTS... 1 (2) Block Diagram of LVDS Driving Board... 3 (3) LVDS Specification... 5 (4) LVDS Timing Specification...
More informationINSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS Product Getac S400 Docking Station Revision Rev. A Form INST-613 7160-0505-00 & 7160-0505-00-P 7160-0505-02 & 7160-0505-02-P Printing Spec: PS-001 This instruction sheet is for
More informationInstallation Manual/Instructions
Installation Manual/Instructions UltraThin ipad Panel Mount Page 1 of 17 REVISION HISTORY REV NO. PAGE NO. DATE DESCRIPTION A ALL 03/01/17 Initial release Page 2 of 17 TABLE OF CONTENTS FOREWARD... 4 GENERAL
More informationCisco TelePresence MCU MSE 8510
Cisco TelePresence MCU MSE 8510 Installation Guide 61-0021-04 August 2013 Contents General information 3 About the Cisco TelePresence MCU MSE 8510 3 Port and LED locations 3 LED behavior 3 Installing the
More information4D Systems. Application Note: 4D-AN-G3001. in ViSi Environment. Document Date: 15 th December Document Revision: 1.0
4D Systems Application Note: Displaying an Image on GOLDELOX Modules in ViSi Environment Document Date: 15 th December 2012 Document Revision: 1.0 2012 4D Systems www.4dsystems.com.au Page 1 of 8 Description
More informationPackard Bell. EasyNote BU Series. Disassembly Guide
Packard Bell EasyNote BU Series Disassembly Guide Table of Contents Overview...3 Technician Notes...3 Disassembly Instructions...3 Reassembly Instructions...3 Required Tools...3 Battery...4 Memory...4
More informationIntroduction to Spreadsheets
Introduction to Spreadsheets Spreadsheets are computer programs that were designed for use in business. However, scientists quickly saw how useful they could be for analyzing data. As the programs have
More informationOptical Line Splitter Installation Instructions
Optical Line Splitter Installation Instructions TECP-96-171 Issue 1 9/2011 Content Page INTRODUCTION............................................................................. 1 1 INSTALLATION.........................................................................
More informationTower to Rack and Rack to Tower System Conversion Guide
Tower to Rack and Rack to Tower System Conversion Guide HP Workstation zx6000 HP Server rx2600 Manufacturing Part Number : A7857-90017 Edition E0802 Copyright 2002 Hewlett-Packard Company. Legal Notices
More informationBiesemeyer Fence Kit Installation Instructions:
Biesemeyer Fence Kit Installation Instructions: Please note this installation kit is designed solely for installation on a Biesemeyer Commercial Fence. Accurate Technology manufactures kits for other saw
More informationUpgrading and Servicing Guide
Upgrading and Servicing Guide The only warranties for Hewlett-Packard products and services are set forth in the express statements accompanying such products and services. Nothing herein should be construed
More informationASUS SpaceLink Access Point WL-300. Quick Start Guide
ASUS SpaceLink Access Point WL-300 Quick Start Guide Copyright Information No part of this manual, including the products and software described in it, may be reproduced, transmitted, transcribed, stored
More informationSerial ATA International Organization
Serial ATA International Organization Version 1.00 29 January 2007 Serial ATA Interoperability Program Revision 1.1 Pre-Test MOI This document is provided "AS IS" and without any warranty of any kind,
More informationSATA Hard Drive Backplane
SATSASBAY425 Instruction Manual SATA Hard Drive Backplane 4-Drive Removable 2.5 SAS/ SATA Mobile Rack Backplane FCC Compliance Statement This equipment has been tested and found to comply with the limits
More informationBioFuel Graphing instructions using Microsoft Excel 2003 (Microsoft Excel 2007 instructions start on page mei-7)
BioFuel Graphing instructions using Microsoft Excel 2003 (Microsoft Excel 2007 instructions start on page mei-7) Graph as a XY Scatter Chart, add titles for chart and axes, remove gridlines. A. Select
More information742S 742i SC742 CHASSIS USER'S GUIDE
742S 742i SC742 CHASSIS USER'S GUIDE 1.0a SC742 Chassis User s Guide The information in this User s Guide has been carefully reviewed and is believed to be accurate. The vendor assumes no responsibility
More information