1 ighting & HVAC Control System DOC# Controllers: AluxM1 AluxM4 AluxM5 Slave relays: AluxS1 AluxS2 AluxS3 AluxS4 Function: Switching off of lighting and HVAC units in un-occupied rooms or areas. Configuration: An AUX control system consists of a controller unit and up to 8 slave relays controlled or switched by the controller. The switching or control signal is low voltage and is done via a "daisy-chain" configuration connecting the slave relays to the controller. The controller receives input from one or more occupancy sensors and switches the slave relays according to its internal logic and customer specified settings. Movement or occupancy detection can be done utilizing occupancy sensors supplied by Deman or any other 3rd party 12 or 24V sensors. Slave relays available: inline unit plug-socket unit voltage free output unit high current unit. The inline and plug-socket slave relays switches power from overhead power ducts to light fittings while the voltage free output slave and high current slave relays are usually used for HVAC or other environmental control purposes. 01

2 Index Wiring example AluxM1 master AluxM4 mini master AluxM5 micro master AluxS1 inline slave AluxS2 high current slave AluxS3 HVAC slave AluxS4 plug/socket slave Product selection guide AluxM1 system example AluxM4 system example AluxM5 system example Related dokuments AUXQ20 Wiring examples 02

3 Wiring example E N M4 E N E N E N S1 S1 S1 E N E N E N (5) E N E N E N M4 Controller or master installed above ceiling. S1 Inline slave relay installed on or near light fitting. S3 HVAC slave relay installed on or near airconditioner, fan-coil unit or other HVAC unit. S3 c m o Occupancy sensor. ight fitting. Occupancy input on HVAC unit. Output from S3 is a change over voltage free contact. Signal cable from master to slave units. Telephone cable with RJ9 plugs on both ends. 12V switching signal. (5) 3core cable to occupancy sensor. 12V or 24V sensors can be utilized. N E air-con 03

4 AluxM1 master Design: delay time setting status indecation EDs output to slave relays (RJ9 sockets) plug in screw terminals Screw terminals: 12V out gnd sens in sens in light switch 12V / 24V DC supply GND Input 1 from sensor (voltage in) Input 2 from sensor (GND in) See wiring of Occupancy sensors Voltage free input from light switch. (closed = on) Bridge when not used. comms gnd ocal network connection HVAC out Voltage free NO output to HVAC controller. Maximum switching capacity: 48V 1Amp. Functioning: Input from occupancy sensor restarts internal timer. Slave relays are switched on when timer is running. Output to slave relays on side of unit. ight switch open causes slave relays to be switched off. Each M1 controller on a local net transmits its sensor input onto the net. All the M1 controllers on the net reacts to these inputs. At least one controller must have a sensor plugged in. Contact is closed when timer is running. Even with light switch open. Status indecation: power sensor lights 230V power to the unit is on. (green) Occupancy sensor input on. (yellow) 12V output to slave relays is on. Flashes if wiring to slave units shorted. (red) Delay time setting: By turning the timer "POT" with a screw driver the minimum on time period can be set from 0 to 32 minutes. Internal logic can lengthen this time if the need arises

5 AluxM1 master (continues) Output to slave relays: Two RJ9 sockets are available for wiring to the slave relays. (A maximum of 9 slave relays) Signal cable from master to slave units is a 4way telephone cable with RJ9 plugs on both ends. slave out slave out Switching signal to the slave relays is 12V. NOTE: The "daisy chain" wiring to the slave units must not loop back. Power in: 230V +- 15% 5VA Sensor supply: 12V or 24V 700mW max. Signal to slave relays: 9 relays max. HVAC out: Voltage free contact. Cotact rating 48V 1A. AluxM4 mini master Design: output to slave relays (RJ9 sockets) occupancy sensor plug status indecation EDs Functioning: Input from occupancy sensor restarts internal timer. Slave relays are switched on when timer is running. A self learning program adapts the timer setting to the environment. Power input:230v (+ 15% -15%) Switching capacity: 8 slave units. 5VA Sensor supply: 12 or 24V DC 700mW max. 05

6 AluxM4 mini master (continues) Occupancy sensor socket (See wiring of occupancy sensors.) Indication EDs power sensor 230V power to the unit is on. (green) Occupancy sensor input on. (yellow) lights 12V output to slave relays is on. Flashes if wiring to slave units shorted. (red) Output to slave relays. RJ9 sockets. Power cord with 5A plug. AluxM5 micro master Design: Power in N E Output to slave relays Power to light fitting N E Occupancy sensor plug Functioning: Input from occupancy sensor restarts internal timer. Slave relays are switched on when timer is running. Internal relay switches with slave relays. A self learning program adapts the timer setting to the occupancy environment. Power input:230v (+ 15% -15%) Switching capacity: 3 slave units. 3,5VA Sensor supply: 12V DC 700mW max. 06

7 AluxS1 inline slave relay screw terminals META BASE Design: RJ9 socket PASTIC CIP-ON COVER Wiring: N E slave in/out Power to light fitting. Non directional RJ9 socket for wiring to master and/or other slave units. Polarity insensitive. Switching : 230V AC 1A free hanging (2 off ECG each with 2x 85W lamps) 2A if fixed to a metal surface. AluxS2 high current slave relay Wiring: Power in Power to load N E N E RJ9 sockets for wiring to master and/or other slave units. Switching : 230V AC 15A 07

8 AluxS3 voltage free output slave relay META BASE RJ9 SOCKETS PASTIC CIP-ON COVER Slave wiring: Relay out NC COMM NO slave in/out RJ9 socket for wiring to master and/or other slave units. Polarity insensitive. Switching : 48V 1A max. AluxS4 plug socket slave relay Slave wiring: Socket side for 5A plug from light fitting Plug pins (5A configuration) to plug into lighting power duct RJ9 sockets for wiring to master and/or other slave units. Switching : 230V AC 3A 08

9 Product isting M1 AuxM1A21 Controller. 24V DC out to occupancy sensor M4 AuxM1A31 AuxM4A11 AuxM4A41 Controller. 12V DC out to occupancy sensor Mini Controller. 12V DC out to occupancy sensor Mini Controller. 24V DC out to occupancy sensor M5 AuxM5A10 Micro Controller 12V DC out to occupancy sensor S1 S2 S3 S4 AuxS1A11 AuxS2A10 AuxS3A10 AuxS4A20 Inline slave relay High current slave relay Voltage free output slave relay Plug-socket slave relay Cl-1806A10 Ceiling mount occupancy sensor 7m diameter sensing area H AuxH10 M1/M4 to slave relay & slave relay to slave relay 3m cable AuxH20 M1/M4 to slave relay & slave relay to slave relay 5m cable AuxH30 M1/M4 to slave relay & slave relay to slave relay 8m cable Aux2KH10 AuxS3 to HVAC controller 2m cable Aux3KH20 M1 to Suren sensor 2m cable Aux3KH30 M1 to Hubbel sensor 2m cable Aux3KH51 Aux3KH70 Aux3KH90 M4 to Suren sensor M4 to Hubbel sensor M4 to eviton sensor 2m cable 2m cable 2m cable 09

10 AluxM1 system example Controller with various slave relays 230V 5A plug duct M1 controller (6) SAVE UNITS (7) (8) S4A20 (9) (6) S1A11 S3A10 M1A12 OCA NET HVAC (5) HVAC I1 A10 IGHT FITTINGS IGHT SWITCH OCCUPANCY Voltage free output to air conditioning system (48V max.) Multi masters area network. External on/off switch (voltage free input). Power and signal connection to occupancy sensor. (12V or 24V sensors) (5) 230V power lead. (6) "Daisy chain" master to slave relays connecting cables (4 core telephone cables with RJ9 plugs) (12V system) (7) Inline slave relays. Switches 230V from power duct to light fittings. (8) Voltage free output slave relay. General purpose change over contact out. (48V max.) (9) Plug-socket slave relays. Switches 230V from power duct to light fittings. 10

11 AluxM4 system example Mini controller with plug-socket slave relays SAVE UNITS 230V 5A power duct 5A plug S4A20 M4 mini controller M4A10 I1 A10 OCCUPANCY SENSOR IGHT FITTINGS S2A10 (5) Power and signal connection to occupancy sensor (12V or 24V sensor) 230V power lead with 5A plug. Plugs into AluxS4A20 slave unit. "Daisy chain" master to slave relays connecting cables (4 core telephone cables with RJ9 plugs) (12V system) Plug-socket slave relays. Switches 220V to light fitting. (5) High current slave relay. AIR-CON. 11

12 AluxM5 system example Micro controller with plug-socket slave relays SAVE UNITS 230V 5A power duct S4A20 5A plug M5 micro controller M5A10 I1 A10 IGHT FITTINGS OCCUPANCY SENSOR S2A10 (5) Power and signal connection to occupancy sensor (12V or 24V sensor) 230V power lead with 5A plug. Plugs into AluxS4A20 slave unit. "Daisy chain" master to slave relays connecting cables (4 core telephone cables with RJ9 plugs) (12V system) Plug-socket slave relays. Switches 220V to light fitting. (5) High current slave relay. AIR-CON. 12

13 Deman Manufacturing (Pty)td 10 Steenbok street Koedoespoort 0186 Pretoria South Africa PO BOX Gezina 0031 Pretoria South Africa tel fax

Global Plasma Solutions. 10 Mall Terrace, Bldg C Savannah, GA (912) ph (877) fax

Global Plasma Solutions. 10 Mall Terrace, Bldg C Savannah, GA (912) ph (877) fax 10 Mall Terrace, Bldg C Savannah, GA 31406 (912) 356-0115 ph (877) 270-5353 fax GPS-RN IOM MANUAL 10 Mall Terrace, Bldg C Savannah, GA 31406 (912) 356-0115 ph (912) 356-0114 fax GPS-RN RTU/AHU INSTALLATION

More information

Temperature Controller

Temperature Controller 2 728 Temperature Controller ultizone Floor Heating Systems RRV817 ultizone model with up to 7 zone outputs by combining 2 RRV817 controllers. Used for central control of underfloor heating systems in

More information

Installation & Operation Guide

Installation & Operation Guide Installation & Operation Guide Direct Digital VAV Controllers KMD-7001/7051 - VAV Terminal Units KMD-7002/7052 - Dual Duct VAV Units KMD-7003/7053 - Fan Induction Units 907-019-01C 1 Introduction This

More information

DESIGO RX Individual room controllers. for fan-coil systems, chilled ceilings and radiators, with LONMARK-compatible bus communications

DESIGO RX Individual room controllers. for fan-coil systems, chilled ceilings and radiators, with LONMARK-compatible bus communications 3 834 DESIO RX Individual room controllers for fan-coil systems, chilled ceilings and radiators, with MARK-compatible bus communications RXC20.1 RXC21.1 The RXC20.1 and RXC21.1 controllers are used for

More information

EcoSystem to 0 10 V- Interface

EcoSystem to 0 10 V- Interface to Interface to Interface 369537i 1 03.22.19 The to Interface provides a control gateway from an link to a compatible lighting device, typically an ED driver. It allows for individual addressing of the

More information

AbstractAVR. Ledbuddy controller. Ledbuddy Panel User Manual 2009 Abstract AVR and Sabre Technology Tel:

AbstractAVR. Ledbuddy controller. Ledbuddy Panel User Manual 2009 Abstract AVR and Sabre Technology Tel: Ledbuddy Panel User Manual 2009 Abstract AVR and Sabre Technology Tel: 0116 278 8078 http://www.abstractavr.com AbstractAVR Ledbuddy controller Page 12 Introduction The LedBuddy is a simple yet powerful

More information

ETM-2050/ETM-2051 Service Manual

ETM-2050/ETM-2051 Service Manual Introduction Novar s Electronic Thermostat Modules (ETMs) are intelligent control modules that provide local, direct digital control of unitary, packaged, staged HVAC systems. This document: Describes

More information

OT EASY 60 II. LED control unit Operating instructions

OT EASY 60 II. LED control unit Operating instructions II LED control unit Operating instructions Contents Safety... 4 General instructions 4 Safety instructions 4 Intended use 4 Description... 5 Function and application 5 Function 5 Important definitions

More information

Installation & Operation Guide

Installation & Operation Guide Installation & Operation Guide (Shown with optional Override Board Cover) KMD-5831 Programmable Loop Controller PLC-28 Direct Digital Controller 902-019-04B 1 Introduction This section provides a brief

More information

Temperature controller Ducted systems

Temperature controller Ducted systems 2 725 Temperature controller Ducted systems Standard model without zoning functions RRV851 Multifunctional controller used for central control of ducted HVAC systems in combination with a QAX850 master

More information

TECHNICAL PRODUCT DATASHEET

TECHNICAL PRODUCT DATASHEET FORM-ENG-0018 REV A 06-02-03 ISO 9001 CERTIFIED Phone: (352) 629-5020 or 800-533-3569 Fax: (352)-629-2902 SUITABLE FOR EXTERNAL DISTRIBUTION TECHNICAL PRODUCT DATASHEET ES-Key Climate Control Module P/N

More information

Fieldbus System. New. New. Series EX260 IP67. Drives up to 32 solenoids. Daisy-chain wiring communication. Compact 28mm

Fieldbus System. New. New. Series EX260 IP67. Drives up to 32 solenoids. Daisy-chain wiring communication. Compact 28mm Fieldbus System (Output device for driving port solenoid valves) Compact 8mm (Actual size) Space-saving Installation Daisy-chain wiring communication New IP67 For units with D-sub connector, and when connected

More information

INTEGRATED SYSTEMS AND CONTROL, INC. User s Hardware Manual. PCMNET V 7. xx

INTEGRATED SYSTEMS AND CONTROL, INC. User s Hardware Manual. PCMNET V 7. xx INTEGRATED SYSTEMS AND CONTROL, INC. User s Hardware Manual PCMNET V 7. xx INTEGRATED SYSTEMS AND CONTROLS, INC. PCMNET Users Manual Revised 2/4/2005 2003-2005 Integrated Systems and Control. Inc. PO Box

More information

M1000 INTELLIGENT ZONE CONTROL SYSTEM

M1000 INTELLIGENT ZONE CONTROL SYSTEM HARDWARE GUIDE DIMENSIONS & SPECIFICATIONS REV. 5.2 M1000 INTELLIGENT ZONE CONTROL SYSTEM ROOFTOP CONTROLLER 2 Table of Contents GENERAL INFORMATION... 3 PL-M1000 Rooftop Controller...3 Description...3

More information

Model BB9 RS-232 Multi-Drop Box. Operating Bulletin. Innovative Flow and Pressure Solutions. Standard 8 pin Mini-DIN Connector

Model BB9 RS-232 Multi-Drop Box. Operating Bulletin. Innovative Flow and Pressure Solutions. Standard 8 pin Mini-DIN Connector Operating Bulletin Standard 8 pin Mini-DIN Connector Model BB9 RS-232 Multi-Drop Box Innovative Flow and Pressure Solutions 6 pin Locking Industrial Connector 1 12/15/2011 Rev.1 DOC-BB9MAN-RS232 2 Alicat

More information

Sensacell Troubleshooting Guide

Sensacell Troubleshooting Guide A ONLY SOME MODULES LIGHT UP B PANEL DOES NOT LIGHT UP Only some modules light up Panel does not light up Check jumpers and power wiring AC Power present at Power Supply input terminals? Check AC Line

More information

Installation & Operation and Maintenance

Installation & Operation and Maintenance Gas Safety Products Dual Current Monitor Installation & Operation and Maintenance Read these instructions carefully before operating or servicing Rev: 01 Date: 12-02-18 1 CONTENTS Chapter Content Page

More information

Starzone 4000 Master Control Panel Figure 2.1 Master Control Panel

Starzone 4000 Master Control Panel Figure 2.1 Master Control Panel Starzone 4000 Master Control Panel Figure 2.1 Master Control Panel The heart of the Starzone 4000 system is the Starzone Master controller (SZM-4000). Each AHU that is to be zoned will have its own SZM-4000

More information

Room unit with PPS2 interface

Room unit with PPS2 interface 1 642 Desigo RX Room unit with PPS2 interface for use with: QAX33.1 devices of the ranges Desigo RXC, RXB, RXL, and RXA (PPS2) Desigo PX Automation stations 1) devices with a PPS2 interface Room temperature

More information

POWERHOUSE. -- the finest in Digital Command Control -- PRODUCT MANUAL FOR PB-110A TEN AMP POWER STATION

POWERHOUSE. -- the finest in Digital Command Control -- PRODUCT MANUAL FOR PB-110A TEN AMP POWER STATION POWERHOUSE TM -- the finest in Digital Command Control -- PRODUCT MANUAL FOR PB-110A TEN AMP POWER STATION NCE Corporation 1260 CREEK STREET Suite 105 WEBSTER NEW YORK 14580 FAX : (716) 671-9337 E-mail:

More information

AS-Interface I/O Module

AS-Interface I/O Module AS-Interface I/O Module Construction The AS-Interface I/O module is designed as a compact, robust field module. It is composed of an electronic module (top) and a coupler module (base). Connectors (standard

More information

ADVANCED TECHNICAL MANUAL AAC1 SMALL SYSTEM CONTROL CONSOLE. Redefine your comfort zone.

ADVANCED TECHNICAL MANUAL AAC1 SMALL SYSTEM CONTROL CONSOLE. Redefine your comfort zone. ADVANCED TECHNICAL MANUAL AAC1 SMALL SYSTEM CONTROL CONSOLE ATM ACC1 Table of Contents Safety Precautions... 3 Overview... 4 Specifications... 4 Installation... 5 Control Console Operation... 9 2 Advanced

More information

4 Channel DMX Driver Instruction Manual

4 Channel DMX Driver Instruction Manual LEDstuff.co.nz 4 Channel DMX Driver Instruction Manual Quality LED Lighting Products The LEDstuff 4 Channel DMX Driver is a flexible module that is an ideal addition to an existing home automation or lighting

More information

BA/BS4S Temperature Sensor Installation & Operating Instructions

BA/BS4S Temperature Sensor Installation & Operating Instructions Product Overview and Identification The BAPI-Stat 4 room temperature sensor features a large format LCD and slider setpoint adjustment. Additional options include button override and communication jack.

More information

Product Information Fan Powered Terminal Unit For under floor ventilation system Type FAT PI/FAT/M/1

Product Information Fan Powered Terminal Unit For under floor ventilation system Type FAT PI/FAT/M/1 TROX Malaysia Sdn. Bhd. (278360-V) 20, Persiaran Bunga Tanjong 1, Senawang Land Industrial Park, 70400 Seremban, Negeri Sembilan Darul Khusus, Malaysia Telephone : (+6) 06-6788188 Telefax : (+6) 06-6788

More information

Andover ContinuumTM Infinet II

Andover ContinuumTM Infinet II Andover ContinuumTM Infinet II The i80 Series controllers are designed for control of Air Handling Units, Roof Top Units, and other mechanical plant equipment. Features 0 Choose the i80 model with the

More information

Content. Product Description

Content. Product Description EY-modulo 4 EY-RU482F001 Room Operating Unit with Display for Fan Coil applications EY-RU483F001 Room Operating Unit with Display for VAV applications en Guidelines for the electrician Content 1 Product

More information

Advantys ETB. DATA SHEET Advantys ETB IP 67 Ethernet Digital I/O Modules. Description. Features

Advantys ETB. DATA SHEET Advantys ETB IP 67 Ethernet Digital I/O Modules. Description. Features Advantys ETB DATA SHEET Advantys ETB IP 67 Ethernet Digital I/O Modules The Advantys ETB family of IP 67 digital I/O modules with direct connection to the Ethernet ( Modbus TCP/IP ) Communication Network.

More information

RTD-RA. realtime. Installation Instructions. English A B. Installation Instructions Control Systems LEDS ALL DIMENSIONS IN MM

RTD-RA. realtime. Installation Instructions. English A B. Installation Instructions Control Systems LEDS ALL DIMENSIONS IN MM RTD-RA Installation Instructions 37.50 LEDS 4 3 2 1 D English Installation Instructions 80.00 80.00 ALL DIMENSIS IN MM C realtime Control Systems A B LEDS 4 3 2 1 D S21 J3 J6 1 2 3 4 J5 5 6 7 0V S1 0V

More information

RXB39.1. Room controller RXB. Communicating room controller for fan-coil applications FC-13

RXB39.1. Room controller RXB. Communicating room controller for fan-coil applications FC-13 s 3 875 RXB Room controller Communicating room controller for fan-coil applications FC-13 RXB39.1 The RXB39.1 room controller is used for temperature control in individual rooms. For 2-pipe or 4-pipe fan-coil

More information

TAC Xenta 101-VF. 3-Speed Fan Coil Controller. TAC Xenta

TAC Xenta 101-VF. 3-Speed Fan Coil Controller. TAC Xenta TAC Xenta TAC Xenta 101-VF 3-Speed Fan Coil Controller TAC Xenta 101-VF is a zone controller intended primarily for fan coil applications with the ability to control fans with multiple speeds, with one

More information

application sheet RAKO CONTROLS WIRED RAK OVERVIEW

application sheet RAKO CONTROLS WIRED RAK OVERVIEW WDA-600 application sheet Introduction When installing a wired system dimmers are typically housed in RAK boxes with either 8 modular cards (RAK8) or 4 fixed type controls (RAK4). These are typically mounted

More information

Active Distributors ASi Safety, IP67

Active Distributors ASi Safety, IP67 x connectors for profile cable Periphery connection via M8 cable sockets M cable sockets (Figure similar) Figure Type Inputs, SIL 3, Cat. 4 9 mm 9 mm 9 mm 9 mm channels channels channels channels Inputs

More information

LRA1750, LRM1763, LCC172x Datasheet OccuSwitch Wireless System

LRA1750, LRM1763, LCC172x Datasheet OccuSwitch Wireless System 1/8 RM1763 Occuswitch Wireless sensor 8.1 mm 25 mm 56.4 mm General description The OccuSwitch Wireless family exists of a wireless sensor and an actuator (relay-box). Savings of up to 30% can be achieved

More information

Non-communicating room controllers

Non-communicating room controllers 3 882 DESIGO RXA Non-communicating room controllers RXA29.1 For fan-coil systems The RXA29.1 room controller are used for temperature control in individual rooms. For 2-pipe or 4-pipe fan-coil systems,

More information

Fiber optic converter audio and CAN TA OPERATION MANUAL

Fiber optic converter audio and CAN TA OPERATION MANUAL Fiber optic converter audio and CAN TA-110.1 IOA110-1 March 2009 LANEX S.A., Technical support: tel. ul.ceramiczna 8, 20-150 Lublin tel. +48 81 443 96 36 Contents 1. General Characteristics.... 5 1.1.

More information

Operating instructions ClassicLine module AC5204 / AC5209 / AC5212 AC5235 / AC5236 / AC5237 AC /00 07/2017

Operating instructions ClassicLine module AC5204 / AC5209 / AC5212 AC5235 / AC5236 / AC5237 AC /00 07/2017 Operating instructions ClassicLine module AC5204 / AC5209 / AC5212 AC5235 / AC5236 / AC5237 AC5274 7390889/00 07/2017 Contents 1 Functions and features...3 2 Operating and display elements...3 3 Installation...4

More information

SK Installation Instructions

SK Installation Instructions Guestroom HVAC Energy Management System SK200-001 Installation Instructions GENERAL SYSTEM COMPONENTS INTRODUCTION The S200 series hospitality HVAC Energy Management (HEM) System is specially designed

More information

Tracer Controls. Tracer MP501 Controller BAS-PRC008-EN. January 2005

Tracer Controls. Tracer MP501 Controller BAS-PRC008-EN. January 2005 Tracer Controls Tracer MP501 Controller January 2005 BAS-PRC008-EN Introduction The Tracer MP501 controller is a configurable, multi-purpose controller used to provide direct-digital control for heating,

More information

ADC7520 SERIES. 1600W Battery Chargers and Power Supplies

ADC7520 SERIES. 1600W Battery Chargers and Power Supplies ADC7520 SERIES 1600W Battery Chargers and Power Supplies Wide output adjustment range 0 72VDC Analog control by external 0-5VDC voltage Temp.comp charging, sense as on option Power fail relay alarm Master-Slave

More information

Basic principles PL. Sending units

Basic principles PL. Sending units asic principles P P technology P (Plusink) is a system for controlling light. The system is based on a conventional electrical installation. ommands are sent via P, and there is no need for either software

More information

Installation and Operation Instructions I/CO 2, I/CO 2 -VDC, I/CO 2 -T

Installation and Operation Instructions I/CO 2, I/CO 2 -VDC, I/CO 2 -T Installation and Operation Instructions I/CO 2, I/CO 2 -VDC, I/CO 2 -T READ THESE INSTRUCTIONS BEFORE YOU BEGIN INSTALLATION LOCATION The I/CO 2 transmitter is designed to mount over a standard single

More information

2M Outdoor Motorized Bullet Camera

2M Outdoor Motorized Bullet Camera 2M Outdoor Motorized Bullet Camera 8608586000010 Quick Installation Guide Please follow the installation steps below to set up your 2MP Bullet IP Camera. Check the package contents against the list below.

More information

Fitting Ah-ha to a machine using Gecko Stepper drives

Fitting Ah-ha to a machine using Gecko Stepper drives Fitting Ah-ha to a machine using Gecko Stepper drives Please note these instructions are for guidance. If you have any doubt on any particular point please check with us. If you have any difficulties in

More information

CTI CALL INFORMATION INTERFACE

CTI CALL INFORMATION INTERFACE CTI CALL INFORMATION INTERFACE MODEL CN-4750 SERIAL/ITEM 533/nnn OPERATOR MANUAL Issue 3, FEB, 2002 AUTHOR: PETER ZEUG PATENTS PENDING DESIGNED AND MANUFACTURED IN AUSTRALIA DESIGN TWO THOUSAND PTY LTD

More information

IQ-MP Gateway. Version apr Electrocom Rødeledsvej 95 DK-5700 Svendborg Denmark Tel :

IQ-MP Gateway. Version apr Electrocom Rødeledsvej 95 DK-5700 Svendborg Denmark Tel : IQ-MP Gateway Version 4.009 28. apr. 2011 Electrocom Rødeledsvej 95 DK-5700 Svendborg Denmark Tel : +45 8880 7580 www.electrocom.dk p. 2 Description The IQ-MP Gateway is a communications module, which

More information

SS-22 USER MANUAL. Revision 01 Original document 04 May 2006 Revision 02 Cosmetic changes 23 January 2008 CONTENTS

SS-22 USER MANUAL. Revision 01 Original document 04 May 2006 Revision 02 Cosmetic changes 23 January 2008 CONTENTS SS-22 User Manual Revision History Revision 01 Original document 04 May 2006 Revision 02 Cosmetic changes 23 January 2008 CONTENTS 1. INTRODUCTION... 3 2. FEATURES... 3 3. DESCRIPTION... 3 4. CONNECTIONS...

More information

Conductive Sensors 2 to 4-point level controller Type CL with teach-in

Conductive Sensors 2 to 4-point level controller Type CL with teach-in Conductive Sensors to 4-point level controller Type CL with teach-in Conductive level controller Teach-in of sensitivity operating resistance from 0Ω to 0KΩ Multiple combinations of filling and emptying

More information

Small distributed I/O module

Small distributed I/O module MLIO Summary Application Function Small distributed I/O module Small I/O module MLIO is a microprocessor-controlled, communiccative module for installation outside the control panel. It is used for topologies

More information

Time Counters mini "h", DC Version

Time Counters mini h, DC Version Type 633-DC Time Counters mini "h", DC Version Type 633.0 Type 633.7 Type 633.8 High shock resistance Miniature dimensions Electrical connections in standard grid Suitable for PCB mounting Machine-solderable

More information

the Interactive Catalog

the Interactive Catalog Interactive Catalog Supplements Catalog PDFs If you need detailed product information, or help choosing the right product for your application, see our Interactive Catalog Use the Interactive Catalog to

More information

CS-1 Active Full Range Integrated Commercial Audiovisual System

CS-1 Active Full Range Integrated Commercial Audiovisual System Active Full Range Integrated Commercial Audiovisual System User Manual SAFETY INSTRUCTIONS PLEASE READ THROUGH THIS MANUAL FIRST BEFORE OPERATING THE CS-1 SYSTEM. Thank you for purchasing this Beta3 product

More information

IP7-MZC Multi Zone Controller ZX4L Zone Expansion. Hardware Installation Manual

IP7-MZC Multi Zone Controller ZX4L Zone Expansion. Hardware Installation Manual IP7-MZC Multi Zone Controller ZX4L Zone Expansion Hardware Installation Manual IP7-MZC ZX4L This page left blank Table of Contents IP7-MZC Zone Controller System... 1 Overview... 1 Technical Specifications...

More information

Room Temperature Controller

Room Temperature Controller 3 023 Room Temperature Controller for four-pipe fan coil units RCC30 Outputs for on / off valve actuators Outputs for three-speed fan Control depending on room or return air temperature Operating modes:

More information

CoolPlug CooLinkHub HVAC Bridge. Quick Installation Guide

CoolPlug CooLinkHub HVAC Bridge. Quick Installation Guide CoolPlug CooLinkHub HVAC Bridge Quick Installation Guide Warning Read and understand the following Safety Guidelines and Warnings to ensure a safe installation Failure to follow WARNING may result in

More information

Manual Control Unit GFC 32

Manual Control Unit GFC 32 Manual Control Unit 1400004_EN/05.2017 Index 1. Main features 3 2. Technical features 3 3. Installation guidelines 4 4. Preliminary checks 5 5. Electrical connections 5 6. Settings 6 7. Remote control

More information

Counting ramp SP User s manual.

Counting ramp SP User s manual. Counting ramp SP2-143 User s manual www.schick-sa.com Table of content 1 Introduction 3 2 LED colours definitions 3 2.1 Normal operating mode 3 3 Installation 3 3.1 Fitting 3 3.2 Connections 3 3.3 Limit

More information

JNIOR Series 4. A Network I/O Resource Utilizing the JAVA Platform. JNIOR Series 4 with 4 Relay Output Expansion Module. Version 5.

JNIOR Series 4. A Network I/O Resource Utilizing the JAVA Platform. JNIOR Series 4 with 4 Relay Output Expansion Module. Version 5. JNIOR Series 4 A Network I/O Resource Utilizing the JAVA Platform JNIOR Series 4 with 4 Relay Output Expansion Module Version 5.0 NOTE: JNIOR JANOS 1.7 or greater required INTEG Process Group, Inc. 2919

More information

DLA. DMX512 Analyzer. DLA Users Manual SV2_00 B.lwp copyright ELM Video Technology, Inc.

DLA. DMX512 Analyzer. DLA Users Manual SV2_00 B.lwp copyright ELM Video Technology, Inc. DLA DMX512 Analyzer DLA DLA-HH 1 Table Of Contents IMPORTANT SAFEGUARDS... 2 DLA OVERVIEW... 3 CONNECTION... 3 OPERATION... 3 HARDWARE SETUP... 4 DLA-HH (PORTABLE) LAYOUT... 4 CHASSIS LAYOUT... 4 DLA MENU

More information

Quick Installation Guide MAC1000/MAC1000SR STANDALONE BIOMETRIC CONTROLLER

Quick Installation Guide MAC1000/MAC1000SR STANDALONE BIOMETRIC CONTROLLER MAC1000/MAC1000SR STANDALONE BIOMETRIC CONTROLLER Table of contents 1 PRODUCT INTRODUCTION... 2 1.1 NAME AND FUNCTION OF EACH PART... 2 1.2 CABLE COLOR TABLE... 4 1.3 CABLE SELECTION... 6 2 IDENTIFYING

More information

VARAN-INTERFACE VAC 012

VARAN-INTERFACE VAC 012 VARAN-INTERFACE VAC 012 This VARAN interface module is used for communication between a DIAS drive and a control over the VARAN bus. The VAC 012 is built into the DIAS-Drive and is also equipped with interface

More information

DUAL LOOP DETECTOR WITH MODBUS COMMUNICATIONS

DUAL LOOP DETECTOR WITH MODBUS COMMUNICATIONS LD220 DUAL LOOP DETECTOR WITH MODBUS COMMUNICATIONS USER MANUAL P.O.Box 24 STANFIELD 3613 SOUTH AFRICA Tel: +27 (031) 7028033 Fax: +27 (031) 7028041 Email: proconel@proconel.com Web: www.proconel.com 18/08/2005

More information

USR-TCP Hard version: V2.0 File version: V

USR-TCP Hard version: V2.0 File version: V Serial Device Server - RS232/RS485 to Ethernet converter USR-TCP232-300 Hard version: V2.0 File version: V1.1 2011-8-17 Serial Device Server - RS232/RS485 to Ethernet converter is an Equipment for convert

More information

Service Section. December 2003

Service Section. December 2003 Service Section December 2003 Network Interface Module (NIM) Family Transceiver Boards NIM NIM PC Ver 2 S-NIM G-WAY NIM TELE Transceiver Boards (TX Boards) Extend the communication distance between the

More information

PA2000 SERIES. USER MANUAL Rev. P CELL PHONE ENTRY SYSTEM. Platinum Access Systems Inc.

PA2000 SERIES. USER MANUAL Rev. P CELL PHONE ENTRY SYSTEM. Platinum Access Systems Inc. PA2000 SERIES CELL PHONE ENTRY SYSTEM USER MANUAL Rev. P Platinum Access Systems Inc. PRODUCT LINE PA2020 --- Cell Phone Entry System PA2022 --- Cell Phone Entry System (Flush Mount) PA2120 --- Cell Phone

More information

Non-communicating room controllers

Non-communicating room controllers 3 881 DESIO RXA on-communicating room controllers For fan-coil systems RXA20.1 RXA21.1 RXA22.1 The RXA20.1, RXA21.1 and RXA22.1 room controllers are used for temperature control in individual rooms. For

More information

Encoder signal/ Sensor signal. Number of monitored axes. sine/cosine, SSI, TTL (1) up to 2 independent axes. sine/cosine. up to 2 independent axes

Encoder signal/ Sensor signal. Number of monitored axes. sine/cosine, SSI, TTL (1) up to 2 independent axes. sine/cosine. up to 2 independent axes w AS-i Speed Monitor for sine/cosine encoder for HTL encoder for SSI encoder for TTL encoder for sensors for 2 fast electronic safe outputs 128 devices Supplied out of AS-i and external 24 V (figure similar)

More information

UNT1100 Series. Binary Output Jumpers AO2 AO1 AO3 AO4 AOCM AOCM AOCM AOCM AO1. AI Switches Job Information N2 Address. Ref N2+ N2- ADDR 0 = ALL OPEN

UNT1100 Series. Binary Output Jumpers AO2 AO1 AO3 AO4 AOCM AOCM AOCM AOCM AO1. AI Switches Job Information N2 Address. Ref N2+ N2- ADDR 0 = ALL OPEN 1 2 8 4 AI6 R R Installation Bulletin UNT1100 Issue Date 0309 UNT1100 Series Introduction The Unitary (UNT) controller (UNT1100 Series) is a digital controller with applications for air handling units,

More information

RTD-NET Installation Instructions

RTD-NET Installation Instructions LED3 SW1 LED4 RTD-NET Installation Instructions 0V +V POWER 15-24VDC English RTD-NET Installation Instructions 100.00 RTD-NET Control Interface realtime Control Systems REMC P1 P2 RS485 D-BUS DB DA GND

More information

AS-i / IO-Link Module, IO-Link Master with 4 IO-Link Ports

AS-i / IO-Link Module, IO-Link Master with 4 IO-Link Ports / IO-Link Module, /IO-Link Module, IO-Link Master with 4 s fourfold IO-Link Master in one housing Power supply of s (or ) (Figure similar) Figure Type Inputs digital 4 x + 4 x + 4 x Outputs digital M12

More information

16-Way Input 48-Way Output Card

16-Way Input 48-Way Output Card 16-Way Input 48-Way Output Card Features 16 Configurable Inputs Push Button, Switch Input Fast Input Response 48 Configurable Outputs OFF, ON, 0.5S ON / 0.5S OFF, 1S ON / 1S OFF Configurable Buzzer OFF,

More information

Quick Draw Electronics. Shooting Sports Timer User Manual. Model AIO-1

Quick Draw Electronics. Shooting Sports Timer User Manual. Model AIO-1 Quick Draw Electronics Shooting Sports Timer User Manual Model AIO-1 Rev. C October 2017 QUICKDRAW ELECTRONICS SHOOTING SPORT TIMER SYSTEM THE SYSTEM CONSISTS OF; 1 IMPACT SENSOR 1 LIGHT ASSEMBLY 1 ALL

More information

DC3IOB Revision User Guide Updated 3/29/10. Overview

DC3IOB Revision User Guide Updated 3/29/10. Overview Revision 080910 User Guide Updated 3/29/10 Overview The is a three axis DC brush motor drive with an integrated PLC. A range of motor drive currents are selectable with jumper blocks. The integrated PLC

More information

MegaPoints Controllers Feedback Module.

MegaPoints Controllers Feedback Module. MegaPoints Controllers Feedback Module. 24 channel feedback module for version 2 MultiPanel Processors. User guide Features include No soldering truly plug and play Various sensor types o DCC and analogue

More information

Installation & Operation Guide

Installation & Operation Guide & Operation Guide KMD-7301/7301C Direct Digital Controller For Air Handling Applications 880-019-02C KMD 7301 and KMD 7301C Direct Digital Controller & Operation Guide Introduction This section provides

More information

Conductive Sensors 2 to 4-point level controller Type CL with teach-in

Conductive Sensors 2 to 4-point level controller Type CL with teach-in Conductive Sensors to -point level controller Type CL with teach-in Conductive level controller Teach-in of sensitivity operating resistance from 0Ω to 0KΩ Multiple combinations of filling and emptying

More information

PC170 Control Box USER MANUAL 24V DC GEAR MOTOR FOR RESIDENTIAL

PC170 Control Box USER MANUAL 24V DC GEAR MOTOR FOR RESIDENTIAL PC170 Control Box 24V DC GEAR MOTOR FOR RESIDENTIAL USER MANUAL INDEX 1. CONTROL BOX 2. SETTING 2.1 SW1 DIP SWITCH SETTING 2.1.1 SLOWDOWN ADJUSTMENT (DIP 1. SLOW) 2.1.2 OVER-CURRENT ADJUSTMENT (DIP 2.OVER

More information

T7560A1036 Digital Wall Module

T7560A1036 Digital Wall Module T7560A1036 Digital Wall Module HONEYWELL EXCEL 5000 OPEN SYSTEM BEFORE INSTALLATION All wiring must comply with local electrical codes and ordinances or as specified on installation wiring diagrams. T7560A1036

More information

75F Smart VAV with Reheat

75F Smart VAV with Reheat A unique system-wide approach to maximizing performance PRODUCT OVERVIEW The wireless control solution reduces install cost, improves energy efficiency, and introduces remote control and diagnostic capabilities

More information

Product Catalog. Tracer Controller MP501 BAS-PRC008-EN. May 2012

Product Catalog. Tracer Controller MP501 BAS-PRC008-EN. May 2012 Product Catalog Tracer Controller MP501 May 2012 BAS-PRC008-EN Copyright 2012 Trane. All rights reserved. This document and the information in it are the property of Trane and may not be used or reproduced

More information

TEMPERATURE CONTROLLER 2 HEAT/ 2 COOL with Digital Room Temperature Display. Made in Australia 100% Australian Owned Company

TEMPERATURE CONTROLLER 2 HEAT/ 2 COOL with Digital Room Temperature Display. Made in Australia 100% Australian Owned Company TEMPERATURE CONTROLLER 2 HEAT/ 2 COOL with Digital Room Temperature Display HTC 5 Features Australian Made and designed Power can be either 24V or 240V AC 10 Amp (Resistive) Potential free relay contacts

More information

Telephone Line Monitor USER GUIDE

Telephone Line Monitor USER GUIDE Telephone Line Monitor USER GUIDE For Technical Assistance call the Manufacturers direct Ph 800 530 8645 8AM - 5PM West Coast Pacific Time NATCOMM USA LLC Responsible Supplier Code NC OPERATION Our Telephone

More information

ST Series - Part Numbering

ST Series - Part Numbering - Part Numbering Features Super-miniature size with multiple contact Safe insert system preventing pin damage Applications Professional A/V Measuring equipment Sensors Wireless radio Medical Part Numbering

More information

Room unit with PPS2 interface

Room unit with PPS2 interface 1 641 DESIGO RX Room unit with PPS2 interface for use with: QAX321 devices of the ranges DESIGO RXC, RXB, and RXA (PPS2) DESIGO PX Automation stations 1) devices with a PPS2 interface Room temperature

More information

clarity 3 Programmable Controller

clarity 3 Programmable Controller clarity 3 Programmable Controller BACnet General Purpose Controllers (B-AAC) DESCRIPTION Taco Clarity 3 FPC series controllers are designed to control building systems and HVAC equipment. The integrated

More information

QAX50.1 QAX50.5 QAX51.1 QAX51.5. Flexible room unit. Desigo RXC

QAX50.1 QAX50.5 QAX51.1 QAX51.5. Flexible room unit. Desigo RXC 1 648 Desigo RXC Flexible room unit for integrated operation of HVAC, lighting and blinds in individual rooms; with LONMARK -compatible bus communication QAX50.1 QAX50.5 QAX51.1 QAX51.5 Room temperature

More information

POWERHOUSE. -- the finest in Digital Command Control -- PRODUCT MANUAL FOR PB-205a DUAL 5AMP POWER STATION

POWERHOUSE. -- the finest in Digital Command Control -- PRODUCT MANUAL FOR PB-205a DUAL 5AMP POWER STATION POWERHOUSE TM -- the finest in Digital Command Control -- PRODUCT MANUAL FOR PB-205a DUAL 5AMP POWER STATION NCE Corporation 1260 CREEK STREET SUITE 100 WEBSTER NEW YORK 14580 FAX : (716) 671-9337 E-mail:

More information

CONTENTS CONTROLLERS room controllers room units control units PRODUAL 3 CATALOGUE

CONTENTS CONTROLLERS room controllers room units control units PRODUAL 3 CATALOGUE Catalogue 207 CONTENTS CONTROLLERS... 4 room controllers... 5 room units... 29 control units... 24 PRODUAL 3 CATALOGUE T U R KU I C T C ON T R OL L E R S Multifunctional controllers for optimal performance

More information

FCU-4 FAN COIL CONTROLLER

FCU-4 FAN COIL CONTROLLER FCU-4 FAN COIL CONTROLLER BACnet Enabled Description The FCU-4 is designed to provide complete control of fan coil units. The FCU-4 incorporates all the inputs and outputs to ensure that this advanced

More information

Manual Simatek Control Unit GFC 32

Manual Simatek Control Unit GFC 32 Manual Simatek Control Unit GFC 32 Original instructions 1400004_GB Ver. 2014.01.09 Index 1. Main features 3 2. Technical features 3 3. Installation guidelines 4 4. Preliminary checks 5 5. Electrical connections

More information

GUARD CENTURION OPERATING INSTRUCTIONS THE AUTOMATIC CHOICE

GUARD CENTURION OPERATING INSTRUCTIONS THE AUTOMATIC CHOICE GUARD CENTURION THE AUTOMATIC CHOICE OPERATING INSTRUCTIONS 0 In a In hurry? a hurry? The following KwikLearn procedure and connection diagram will enable you to start using your SmartGUARD system right

More information

Sirius Light Source Range

Sirius Light Source Range Light Source User Guide Sirius Light Source Range Models covered by this manual: UFOSIRCW UFOSIRCW-C UFOSIRCW-T UFOSIRCW-Cs UFOSIRCW-Ts UFOSIRSW UFOSIRSW-C UFOSIRSW-T UFOSIRSW-Cs UFOSIRSW-Cs UFOSIRNW UFOSIRNW-C

More information

C5S120 Installation and Connection Guide

C5S120 Installation and Connection Guide C5S120 Installation and Connection Guide Version: V1.1 1. Cautions Please note the following cautions. Mis-operation may lead to personal injury or equipment failure: 1) Do not energize the system before

More information

DFM44E Series. Installation Instructions. System Requirements: Win 95b/98/Me/2000/XP Resolution: 1024 x MB RAM

DFM44E Series. Installation Instructions. System Requirements: Win 95b/98/Me/2000/XP Resolution: 1024 x MB RAM DFM44E Series Installation Instructions Copyright 2003. Maxitrol Company. All Rights Reserved. System Requirements: Win 95b/98/Me/2000/XP Resolution: 1024 x 768 32MB RAM Read Before Installation DFME Amplifier

More information

Defining the Future in Motion Control

Defining the Future in Motion Control Defining the Future in Motion Control USER S MANUAL 1 DINIO7 user s manual Overview The DINIO7 is a DIN-rail mounted peripheral for the SmartMotor versions 3 and 4 product lines Hereafter, the SmartMotor

More information

RangerBOSS Network Ready Constant Monitor Model CM2800

RangerBOSS Network Ready Constant Monitor Model CM2800 RangerBOSS Network Ready Constant Monitor Model CM2800 Instruction Manual Contents 1 Description CM2800 1 Features 1 2 Installation Installation Instructions 2 Installation Diagram 3 3 Operation Wrist

More information

CT1 Series 2. General Purpose Timer. Installation Manual 1 st Edition

CT1 Series 2. General Purpose Timer. Installation Manual 1 st Edition CT1 Series 2 General Purpose Timer Installation Manual 1 st Edition FEATURES 4 Timing Ranges: - 1 to 127 seconds in 1 second increments. - 10 seconds to 21 minutes in 10 second increments. - 1 to 127 minutes

More information

PTC Model III. Programmable Turntable Controller. Automatic Power Router. Installation Instructions

PTC Model III. Programmable Turntable Controller. Automatic Power Router. Installation Instructions PTC Model III Programmable Turntable Controller A Automatic Power Router Installation Instructions New York Railway Supply 13225 Thornton Dr Westlake, TX 76262 (817) 233-5068 http://www.nyrs.com NYRS Inc2010,

More information

Digital Keypad Introduction

Digital Keypad  Introduction K2 Digital Keypad Introduction The K02 uses the latest microprocessor technology to operate door strikes and security systems that require a momentary (timed) or latching dry contact closure. All programming

More information

PI84 with socket GZM80 interface relays

PI84 with socket GZM80 interface relays RM84 + GZM80 Contact data Number and type of contacts Contact material Rated / max. switching voltage Min. switching voltage Rated load (capacity) Min. switching current Max. inrush current Rated current

More information