1 SMARTbox IO Agent User Guide Cloud Fieldbus PSSYSTEC GMBH HEINBERGSTR NEUSÄSS
2
3 PSsystec SMARTbox IO Agent User s Guide Contents Overview...4 Interface...5 Connect the Smartbox to your Cumulocity Account...5 Use the biult-in IOs...6 Manage Software...7 Use the built-in location functionality...7 Use the built-in tracking functionality...8 Change Tenant and URL by SMS...9 Remotely execute text commands via device shell...9 Debug the device...10 Connect Modbus devices with Cloud fieldbus...10 Help for setup the items in device database...12 PSsystec SMARTbox IO Agent User Guide 3
4 Overview Smartbox, based on the Telit Chipset HE910 is a ready to use solution for connecting Modbus devices to the Cumulocity Fieldbus Cloud. It provides a Master Slave Communication on RS485 for connecting up to 20 devices as well as 10 Sensors (Current, Temperature, Pressure). Easy configure the SetUp of building automation fielddevices like pumps, e-meters, Airhandling units in the Cumulocity Fieldbus cloud or connect different sensortypes to the box. Using the Smartrest protocol the terminal comes up with a low traffic solution for decentralized applications. For the Smartbox there is a customized user interface available made for easy handling the sensors and showing graphs for consumption and temperatures. For further information: please refer to the datasheet provided by PSsystec For installing the agent and SW releases, please refer to Release notes folder of device guide in Cumulocity or go to For getting the device please contact Cumulocity Hardware support or Pssystec (kontakt@pssystecgmbh.de) 4 PSsystec SMARTbox IO Agent User Guide
5 Interface Connect SMARTbox IO to the power supply 24VDC. The start-up of the unit will take 60 seconds: Wire your network: Wire the sensors: Connect the Smartbox to your Cumulocity Account Configure the terminal: By default the terminal supports cloud fieldbus from Cumulocity. To use it you should: Subscribe your account to the Cloud Fieldbus app by contacting support. Configure the terminal: 1. Power on the Terminal. 2. Configure the Terminal s APN by sending an SMS to Terminal s SIM card with the following syntax: GPRS=APN,username,password (e.g. GPRS==public4.m2minternet.com,,) PSsystec SMARTbox IO Agent User Guide 5
6 Registering the Terminal in Cumulocity: In the cumulocity Cloud Fieldbus app go to the menu and there find Devices Registration. Enter the Terminal s IMEI as an ID. The IMEI is printed on the devices itself: After accepting the device you should be able to see it in the All Devices list within 30 seconds. Use the biult-in IOs Sensors - max. 10: IO Board V1 U1/ U2 DIN [voltage free] / 0-20mA [supplied by Smartbox] / 0-10V U3/ U4/ U5/ U6 DIN [voltage free] / 0-20mA [supplied by Smartbox] U7/ U8/ U9/ U10 PT1000 IO Board V2 U1...U6 DIN [voltage free] /NTC/PT100/PT1000/ 0-10V OR 0..20mA U7..U10 DIN [voltage free] /NTC/PT100/PT1000 Relay Switch 1 x 230V - 2A U1...U10 Input sensor type NTC PT V 0-10V 4-20mA (incl. power supply input) DIN 0-5V (incl. power supply input) PTC PT500 6 PSsystec SMARTbox IO Agent User Guide
7 Relay Switch PT100 DIN_COUNT DIN_FREQ Output 0-10V KHz 1 x 230V - 2A To activate the specific sensorboard proceed as follows: 1. Upload the sensor-model in device database. Download the sensorboard model Type A here 2. Edit the model if you need it (refer to Configuring Fieldbus device types) but keep the addresses 3. Connect the sensor board in Modbus tab on adress 1 4. Include the fieldbus widget in the cockpit related to the device and activate all items. You can now configure the inputs as Temperature sensor or Digitalinputs- as described in the table above Manage Software The installed software on the SMARTbox can be remotely managed using the standard software and management feature from Cumulocity, as described in the Device management user s guide. You can get the latest Software version in the Release notes folder of Device guide in Cumulocity or go to: Since version 2.0 or higher all version are up compatible. Use the built-in location functionality The terminal features cell location and is available in Location tab on terminal level. Devices are shown as pins that you can click to see the name of the device. Clicking the name of the device takes you to the detailed view of the device. In Smartbox Mini you have 3 Options: 1. Using the built in Cell Location. The terminal identifies 3 cells in the near environment and derives the location (default) 2. Using the hardware Option with a built in- GPS (this is an extra option). Set c8y.gps=1 then GPS is enabled. Setting c8y.gps=0 Cell location is enabled. 3. Activate a regular identification of the location. In Configuration tab you can set: 1. c8y.locationcycle=60; define in min, how often the location should be checked. 0 means the cycled checking is disabled. If a value >0 is set, also the tracking is enabled PSsystec SMARTbox IO Agent User Guide 7
8 Use the built-in tracking functionality Devices can record the history of their movements in Cumulocity. Using the tracking tab, you can select a time period and visualize the movements of the device during this time period. Movements are shown as red lines on the map. Next to the map, the individual recordings with their time are listed ( location update events ). When you click a recording, a pin on the map will show the location at the time of the recording. Activate a regular identification of the location. In Configuration tab you can set. If the value of c8y.locationcycle is greater 0 then tracking is enabled. 8 PSsystec SMARTbox IO Agent User Guide
9 Depending on the type of device and the integration into Cumulocity, you can also configure device-side geo-fencing and motion detection. Additionally, when the feature is activated, Cell ID information can be used to determine the position of the device. Currently, the services from Combain and Google are supported. The user can see the tracks based on both data, or filter out GPS based data or Cell ID based data. Change Tenant and URL by SMS Change tenant Change URL Note: To change tenant: Send an SMS to the SMARTbox by typing DELETE. The device will delete the stored crediantels and performs an restart. After this you will be able to register the device in an other tenant but with same Url (.ram.m2m.telekom.com). To change URL: Send an SMS to the SMARTbox by typing URL=<newurl> e.g. URL=test-ram.m2m.telekom.com. Note: By executing this command, also the crediantels will be deleted from the device. don t forget to delete the device in your registered tenant to prevent scrap in your tenant. Remotely execute text commands via device shell The device shell enables you to read and write configuration parameters to interactively work with remote devices. You can send AT commands in the respective language of the device and view the results of the commands. You can sent any At Command. Check here in Chapter AT commands:: Frequently used commands are available by clicking the Get predefined button. Multiple get, set and execute commands can be sent using a semicolon as separator. PSsystec SMARTbox IO Agent User Guide 9
10 Debug the device For debug service: Install the Telit USB driver on your PC: The PC will recognize 6 new USB Ports Open an Terminal program Connect your PC on Telit High Speed Modem USB Port with USB port on the Smartbox You will get details of the running machine. Connect Modbus devices with Cloud fieldbus Support Modbus RTU: Type Baudrate Parity Stopbits Functioncodes Datapoints Polling Rate on Bus Modbus RTU (Master) 4800, 9600, 19200, 38400, (Change during Runtime possible) Even, ODD, NONE (Change during Runtime possible) 2,1 (Change during Runtime possible) Funct.1 (Read Single Coils) Funct.2 (Read Input Status) Funct.3 (Read Holding Registers) Funct.4 (Read Input Registers) Funct.5 (Write Coil) Funct.6 (Write Holding Register) Max 10 Slaves with each 100 datapoints 300ms To connect a Modbus/RTU device: Physically wire the Modbus/RTU device through RS/485 to the terminal. Give the device a unique Modbus address according to the instructions provided with the Modbus device (e.g. by setting a jumper on the device). Check the serial communication settings of the device according to the instructions provided with the device (i.e. baud rates and communication protocol). These have to match with all devices on the bus. Navigate to the terminal in Cumulocity and click on the Modbus tab. Change the communication settings shown in the section Serial Communication to match the settings on the bus, if needed. Change the transmit rate and the polling rate according to your requirements. The polling rate is the frequency at which the Modbus devices are polled for changes. The transmit rate is the frequency where measurements are sent to Cumulocity. Click Save changes if you made changes. To start communication between the terminal and the Modbus device, click Add new device. Enter a name for the device and select the type of the device from the drop-down box. To add new device types, see Configuring Fieldbus device types below. Set the Modbus address of the connected device. Click Add. Cumulocity will now send a notification to the Modbus terminal that a new device is ready to be managed. This may take a few seconds. 10 PSsystec SMARTbox IO Agent User Guide
11 PSsystec SMARTbox IO Agent User Guide 11
12 Help for setup the items in device database 12 PSsystec SMARTbox IO Agent User Guide
13 PSsystec SMARTbox IO Agent User Guide 13
14 PSSYSTEC GMBH HEINBERGSTR NEUSÄSS
SMARTbox Cube IO Agent User Guide. Cloud Fieldbus PSSYSTEC GMBH HEINBERGSTR NEUSÄSS
SMARTbox Cube IO Agent User Guide Cloud Fieldbus PSSYSTEC GMBH HEINBERGSTR. 27 86 356 NEUSÄSS WWW.PSSYSTEC-GMBH.DE SMARTbox CubeIO Smartbox, based on the Telit Chipset HE910 is a ready to use solution
More informationApplication Manual. Cloud Fieldbus. PSsystec SMARTbox Agent User s Guide
Application Manual Cloud Fieldbus Overview Smartbox Modbus, based on the Telit Chipset HE910 is a ready to use solution for connecting Sensors and in parallel Modbus devices to the Cumulocity. It provides
More informationVersion 1.0c May 6, 2010 ATK3
Version 1.0c May 6, 2010 ATK3 Contents 1 Hardware 2 1.1 Inputs............................... 2 1.2 Outputs.............................. 3 1.3 RS485............................... 3 1.4 Ethernet..............................
More informationDKG-210 UNIVERSAL INTERNET GATEWAY UNIT
DKG-210 UNIVERSAL INTERNET GATEWAY UNIT AC & DC SUPPLY VERSIONS DESCRIPTION The DKG-210 is designed for internet monitoring and control of industrial devices using different protocols through the RAINBOW
More informationSDM-6RO. Expansion Module 6 relay outputs. Manufactured for
Version 1.0 5.02.2014 Manufactured for Thank you for choosing our product. This manual will help you with proper support and proper operation of the device. The information contained in this manual have
More informationIntech Micro 2300-A8VI analogue input station MODBUS RTU slave application supplementary manual.
Intech Micro 2300-A8VI analogue input station MODBUS RTU slave application supplementary manual. MODBUS supplementary manual to the 2300-A8VI Installation Guide. The 2300 series stations are designed to
More informationNetBiter I/O Extender User Manual
User Manual Part no. 0920-9999-009 IntelliCom Innovation AB Pilefeltsgatan 73 SE-302 50 Halmstad SWEDEN Phone +46 35 17 29 90 Fax +46 35 17 29 09 email info@intellicom.se www www.intellicom.se Revision
More informationReal Time Clock with Temperature Sensor and RS485/Modbus Comunications
Real Time Clock with Temperature Sensor and RS485/Modbus Comunications April 29, 2014 Power 8 20 VDC @ less than 100 MA. Battery connect jumper RS485 Bus Load Jumpers Model: RTC-TI2C Page 1 of 6 Features:
More informationKTA-250 Anemometer Alarm Card
Connects to Davis Instruments DS7911 Anemometer Monitor both the wind speed and direction Interface to PLCs using the Modbus protocol Communicate via RS232 or 2-wire RS485 Interface to PLCs/Instruments
More informationMOD-IO9 Modbus Input / Output Modules, Wall Mounted
Product sheet MOD3.9 Type MOD-IO9 MOD-IO9 Modbus Input / Output Modules, Wall Mounted MOD-IO9 and MOD-IO9-AI have been designed to be a compact wall mounted Modbus RTU input and output module. The module
More informationIntech Micro 2300-RTD6 analogue input station MODBUS RTU slave application supplementary manual.
Intech Micro 2300-RTD6 analogue input station MODBUS RTU slave application supplementary manual. MODBUS supplementary manual to the 2300-RTD6 Installation Guide. The 2300 series stations are designed to
More informationSATEL I-LINK 100 MB I/O-converter User Guide, Version 1.1
TABLE OF CONTENTS TABLE OF CONTENTS... 1 IMPORTANT NOTICE... 2 PRODUCT CONFORMITY... 3 WARRANTY AND SAFETY INSTRUCTIONS... 4 1 GENERAL... 5 1.1 SATEL I-LINK 100 MODBUS I/O- CONVERTER... 5 2 SPECIFICATIONS...
More informationRTU300 SERIES HARDWARE MANUAL
RTU300 SERIES HARDWARE MANUAL RTU310/RTU320/RTU330/RTU340/RTU350 RTU Series 10 / 2017 MIKRODEV_HM_RTU300_EN V1.0 CONTENT 1 RTU300 GENERAL INFORMATION... 7 1.1 Physical Interfaces... 7 1.2 General Device
More informationIntech Micro 2300-RO4 analogue input station MODBUS RTU slave application supplementary manual.
Intech Micro 2300-RO4 analogue input station MODBUS RTU slave application supplementary manual. MODBUS supplementary manual to the 2300-RO4 Installation Guide. The 2300 series stations are designed to
More informationUser Manual Revision English
Document code: MN67561_ENG Revision 1.001 Page 1 of 12 User Manual Revision 1.001 English Gateway ProfiBus Slave to Serial Communication Master (Order Code: HD67561) for Website information: www.adfweb.com?product=hd67561
More informationSC168MBM 16x8 Characters MODBUS MASTER LCD
Product Description SC168MBM is a programmable LCD that serve as MASTER RTU MODBUS device. It reads and display registers values from MODBUS Slave devices through its RS485 port. The LCD can be configured
More informationRS485 MODBUS Module 6RO
Version 2.0 12/02/2013 Manufactured for Thank you for choosing our product. This manual will help you with proper support and proper operation of the device. The information contained in this manual have
More informationRS485 MODBUS Module 8AO
Version 1.3 12/02/2013 Manufactured for Thank you for choosing our product. This manual will help you with proper support and proper operation of the device. The information contained in this manual have
More informationGPRS/SerialGateway. GPRS/Serial Gateway. User Manual
GPRS/Serial Gateway User Manual 1 TABLE OF CONTENTS SECTION 1 GENERAL INFORMATION...5 1.1 General Information... 5 1.2 Proper Use and Safety Conditions... 6 1.3 Connections and Micro SIM Card Placement...
More informationELSETA IOMOD 8DI8DO. User manual. Elseta 3/2017 V1.0
ELSETA User manual Elseta 3/2017 V1.0 COPYRIGHTS AND TRADEMARKS Elseta is UAB Aedilis trademark that identifies UAB Aedilis manufactured products. All of the products copyright belongs to "Aedilis. These
More informationSDM-8AO. Expansion Module 8 analog outputs. Manufactured for
Version 1.0 16.05.2014 Manufactured for Thank you for choosing our product. This manual will help you with proper support and proper operation of the device. The information contained in this manual have
More informationRS485 MODBUS Module 8I8O
Expansion Module 8 digital inputs, 8 digital outputs Version 2.2 12/01/2014 Manufactured for Thank you for choosing our product. This manual will help you with proper support and proper operation of the
More informationAirCare General Purpose ModBus Interface ACM1001. OptiDrive Modbus Module Product Specification. For assistance call
OptiDrive Modbus Module Product Specification AirCare General Purpose ModBus Interface ACM1001 Features Modbus RTU network interface Works with any Invertek OptiDrive Closed loop control optio - External
More informationRemote I/O Modules EH-RIO2 Series
Remote I/O Modules EH-RIO2 Series Fieldbus adapter: ProfiNET, EtherCAT, Modubus TCP / RTU, Profibus-DP, DeviceNet Separation of electronics module and terminal block for easy installation and maintenance
More informationWE CONNECT REAL WORLD STRUCTURAL MONITORING SMART SENSORS SOFTWARE CLOUD WIRELESS INTERFACE TO THE
WE CONNECT REAL WORLD TO THE STRUCTURAL MONITORING SENSORS WIRELESS INTERFACE SOFTWARE CLOUD Rev.10 del 3/10/017 Redatto da: R&D e MKT Approvato da: CEO Smart structural WIRELESS Interface NI00 devices
More informationATK3 I/O Module (Modbus Slave)
ATK3 I/O Module (Modbus Slave) 2011-01-13 The ATK3 I/O Module by ElectroCom Table of contents 2011-01-13...1 The ATK3 I/O Module by ElectroCom...1 1 Hardware...2 1.1 Inputs...3 1.2 Outputs...3 1.2.1 Relay...3
More informationSubmittal Data Sheet WAGO Node for itm
The WAGO Node integrates ancillary equipment into the Intelligent Touch Manager (itm) DCM601A71 with the use of DI, DO, AI and AO signals. It provides monitoring and control of non-daikin equipment via
More informationSDM-8I8O. Expansion Module 8 digital inputs, 8 digital outputs. Manufactured for
Version 1.2 20.01.2014 Manufactured for Thank you for choosing our product. This manual will help you with proper support and proper operation of the device. The information contained in this manual have
More informationMX-1 GSM/GPRS M-BUS DATA LOGGER USER MANUAL
MX-1 GSM/GPRS M-BUS DATA LOGGER USER MANUAL JSC VILTRUS K. Donelaičio str. 62, Kaunas, Lithuania Phone: +370 640 65040 E-mail:sales@viltrus.com Web: www.viltrus.com CONTENTS 1 Abbreviations and explanations...
More informationUSER MANUAL. Modbus IHP24-A IHP24-AF IHP24-B IHP24-BF IHP24-F IHP24-I 1/26
USER MANUAL Modbus IHP24-A IHP24-AF IHP24-B IHP24-BF IHP24-F IHP24-I 1/26 Table of contents 1 General... 3 1.1 Safety instructions... 3 2 Purpose... 4 3 Specifications... 5 3.1 Electrical specifications
More informationNF760 Batch Controller
NF760 Batch Controller Overview The NF760 Batch Controller is suited to flow applications where precise measurement and control of batch quantities is required. Batch total, flow rate, accumulated total
More informationTR600 with RS485 Appendix 1
c ZIEHL industrie elektronik GmbH + Co KG Daimlerstraße 13, D 74523 Schwäbisch Hall + 49 791 504-0, info@ziehl.de, www.ziehl.de Temperature Relays and MINIKA Mains Monitoring Digital Panelmeters MINIPAN
More informationICP DAS. ICP DAS 2015 M2M WLAN Wireless Solutions
ICP DAS 2015 M2M WLAN Wireless Solutions Industrial Computer Industrial Product Data Computer Acquisition Product System Data Acquisition System PAC WLAN Wireless Solutions Wi-Fi Products WLAN Converter
More informationiologik R1200 Series User s Manual
User s Manual Edition 3.2, November 2017 www.moxa.com/product 2017 Moxa Inc. All rights reserved. User s Manual The software described in this manual is furnished under a license agreement and may be used
More informationRS485 MODBUS Module 16I-M
Version 2.0 12/02/2013 Manufactured for Thank you for choosing our product. This manual will help you with proper support and proper operation of the device. The information contained in this manual have
More informationFeatures and Benefits. Certifications
iologik R1200 Series RS-485 remote I/O Features and Benefits Dual RS-485 remote I/O with built-in repeater Supports the installation of multidrop communications parameters Install communications parameters
More informationWarranty. Warning. Copyright. Contact Us
M-6026U-32 16-channel Universal Input and 16-channel Universal Output Version: 1.0.0 Date: Dec. 2017 Edited by Horse Chien M-6026U-32 User Manual Version 1.0.0 Dec. 2017-1 - Warranty All products manufactured
More informationRS485 MODBUS Module 8I8RO
Expansion Module 8 digital inputs, 8 relay outputs Version 1.0 3.12.2014 Manufactured for Thank you for choosing our product. This manual will help you with proper support and proper operation of the device.
More informationRS 485 Mini Modbus 1AO
RS 485 Mini Modbus 1AO Version 1.0 14/08/2014 Manufactured for Thank you for choosing our product. This manual will help you with proper support and proper operation of the device. The information contained
More informationPen Drive USB Datalogger!
SINGLE PHASE POWER METER Isolated V/I converter -RS485 Modbus - Datalogger Single-phase power meter RMS, and Voltage/Current Isolated. Signal Converter 1000 VDC / 600 VAC, 10 A AC/DC, Variable frequency
More informationTRAINING GUIDE LEVEL 3 MODBUS WRITE IMPORT COMMAND
OleumTechTM TRAINING GUIDE LEVEL 3 MODBUS WRITE IMPORT COMMAND MUST BE FAMILIAR WITH LEVEL 1 TRAINING MATERIALS BEFORE MOVING FORWARD Doc ID# 80-6010-001b TABLE OF CONTENTS 1. WHAT IS NEW WRITE IMPORT
More informationiologik R1200 Series User s Manual
User s Manual Edition 3.3, February 2018 www.moxa.com/product 2018 Moxa Inc. All rights reserved. User s Manual The software described in this manual is furnished under a license agreement and may be used
More informationiologik R1200 Series User s Manual
User s Manual First Edition, April 2013 www.moxa.com/product 2013 Moxa Inc. All rights reserved. User s Manual The software described in this manual is furnished under a license agreement and may be used
More informationWebNMS IoT Cloud Gate Deployment Guide
Table of Contents Introduction... 3 IoT Structure... 3 Cloudgate Gateway Device... 7 System Requirements... 7 Prepare the CloudGate Device... 11 Compatible Sensors... 23 Analog sensors... 23 Digital Input
More informationCAS Danfoss AK-SC-255 XML Interface Modbus (RTU and TCP) and BACnet and HTML Gateway
CAS-2700-15 Danfoss AK-SC-255 XML Interface Modbus (RTU and TCP) and BACnet and HTML Gateway Description The Danfoss XML Rest Driver allows the Gateway connect to a Danfoss systems and poll for real time
More informationOcean Controls KTA-224 Modbus IO Module
Ocean Controls Ocean Controls 8 Relay outputs (5A, 250VAC contacts) 4 Opto-Isolated Inputs with counters 3 Analog Inputs (10 bit) jumperselectable for 0-5V or 0-20mA 4 Input Counters RS485 or USB (virtual
More informationOpen Smart Metering Gateway EWIO-9180-M. Energy consumption monitoring and energy monitoring in buildings, on machines, installations and systems
Open Smart Metering Gateway EWIO-9180-M Energy consumption monitoring and energy monitoring in buildings, on machines, installations and systems Open Smart Metering C Logline Powerful components for energy
More informationList of Contents 1. INTRODUCTION DEFINITIONS AND ABBREVIATIONS REFERENCES TECHNICAL DATA GENERAL MODBUS RTU...
MAGX2 RTU User Guide -0- V1.5 23-01-2018 List of Contents 1. INTRODUCTION... 2 1.1 DEFINITIONS AND ABBREVIATIONS... 2 1.2 REFERENCES... 2 2. TECHNICAL DATA... 3 2.1 GENERAL MODBUS RTU... 4 3. COMMISSIONING...
More informationE2 Modbus RTU Register Map Revision History Version Comments Author Date 1.02 Previous version PAE 11/06/ Revised to new format PAE 09/03/09
Application Note Title AN-ODE-01 E2 Modbus RTU Register Map Revision History Version Comments Author Date 1.02 Previous version PAE 11/06/08 1.03 Revised to new format PAE 09/03/09 General This document
More informationModbus RTU Serial Communication User Manual
Modbus RTU Serial Communication User Manual Version: BA-2017.07.05 ASV Stübbe GmbH & Co.KG Print-No.: 301244 Hollwieser Straße 5 MA EN Rev001 32602 Vlotho Germany Phone: +49 (0) 5733-799-0 Fax: +49 (0)
More informationDocument Name: User Manual for SC10MK, Modbus RTU to Modbus TCP Converter
Document Name: User Manual for SC10MK, Modbus RTU to Modbus TCP Converter Login for the first time, please use http://192.168.1.100 To key in user name and password is for identifying authorization. Default
More informationUser Manual Revision 1.02
User Manual Revision 1.02 Manufactured by Contents 1. Introduction... 4 2. Disclaimer and Warranty... 4 3. Specifications... 5 4. Features... 5 5. Quick Start Guide... 6 5.1 Hardware... 6 5.2 Software...
More informationCAS OPW Fuel Management Systems Gateway Modbus (RTU and TCP) and BACnet IP and Web (HTML, REST, JSON, XML, CSV, COSM)
CAS-2700-40 OPW Fuel Management Systems Gateway Modbus (RTU and TCP) and BACnet IP and Web (HTML, REST, JSON, XML, CSV, COSM) Description The OPW Fuel Management Systems Gateway uses the Veeder Root TLS
More informationBQ & BQ370-01N MODBUS ANALOG INPUT DEVICE USER MANUAL
BQ370-01 & BQ370-01N MODBUS ANALOG INPUT DEVICE USER MANUAL (Modbus PT Temperature Sensor Reader) Document Version 1.2.0 Content Content 2 About BQ370 Device Family 3 About Device 3 Device Properties 4
More informationMDC 700 Series User Manual
MDC 700 Series User Manual November 2014, Version 1.00 The MDC 700 series module is a Modbus Data Concentrator that has the ability to communicate with up to 127 Modbus slave devices using Modbus RTU protocol.
More informationMXIO. Compact I/O module. Summary. Application Compact I/O module for data acquisition and HVAC control systems. Function
MXIO Compact I/O module Summary The MXIO multiple I/O compact module is a microprocessor-controlled, communicative module with the I/O mix optimized for larger HVAC control applications. The module uses
More informationUsing Ontrol dedicated IO devices with the R-ION. 1/12 R-ION with dedicated I/O Device
Using Ontrol dedicated IO devices with the R-ION 1/12 R-ION with dedicated I/O Device R/MIO and R/TIO Devices R/MIO and R/TIO are dedicated input/output modules only for use with the R-ION room controllers.
More informationINTEGRATED SYSTEMS AND CONTROL, INC. User s Hardware Manual. PCMNET V 7. xx
INTEGRATED SYSTEMS AND CONTROL, INC. User s Hardware Manual PCMNET V 7. xx INTEGRATED SYSTEMS AND CONTROLS, INC. PCMNET Users Manual Revised 2/4/2005 2003-2005 Integrated Systems and Control. Inc. PO Box
More informationMP211 HARDWARE MANUAL
MP211 HARDWARE MANUAL MP211 PLC Series 10 / 2017 MIKRODEV_HM_MP211_EN V1.1 CONTENTS 1 MP211 GENERAL INFORMATION... 6 1.1 Physical Interfaces... 6 1.2 General Device Specifications... 7 2 INSTALLATION INFORMATION...
More informationUSER GUIDE PEL / PEL-M
V2.0.0 (05.09.2014) 1 (6) COMMISSIONING Mounting - The transmitter should be installed above the measuring point to avoid condensation problems. - The duct overpressure is detected by connecting the measuring
More informationGEN II Wireless GSM/GPRS Data Acquisition System
Real time and historic data is sent via GPRS to the main server where it is written to a MySQL database Server MySQL Database SMS alarm messages sent to mobile phones Email alerts and reports sent to specified
More informationSCC Inc. LMV5 Series. Installation Instructions. Document No. LV February 12, 2018
Installation Instructions February 12, 2018 OCI415.30 for use with LMV5... Linkageless Burner Management Systems OCI415.30 Description The OCI415.30 provides the LMV5... family of flame controllers with
More informationFeatures. Target Applications. V1.6 TBS07 RS485 to SDI-12 Converter
The is an interface box for connecting a PC, data logger or telemetry unit to one or more sensors with SDI-12 interface. The connects to a data logger, telemetry unit or other device with RS485 interface
More informationAsset Management. Facility Management. Total Solutions. Supply Chain Management. Utilities. Series 4500
Asset Facility Total Solutions Supply Chain Utilities Series 4500 Series 4500 - RTU32 Controller POWERFUL RTU AND INDUSTRIAL CONTROLLER The new Brodersen RTU32 Controller is a powerful RTU offering real
More informationLoRaWAN Wzzard Utility Quick Guide. v /11/1
LoRaWAN Wzzard Utility Quick Guide v1.0 2018/11/1 1. Connect LRPv2 Connect LoRaWAN LRPv2 node and your desktop with MicroUSB. An USB virtual COM port will be created in Windows system. If Windows can t
More informationIn addition, REWIND can be used to set a connection with the monitoring software SICES SUPERVSIOR.
REWIND: Electronic device that, using GSM/GPRS technology and being connected to a genset, a tower light, a tank, etc., automatically sends data to a central software called SI.MO.NE (Sices Monitor Network).
More informationProfiMessage. NEW Modular. Secure. Adaptable.
ProfiMessage NEW Modular. Secure. Adaptable. ProfiMessage Modular data acquisition Modular and secure ProfiMessage is the new modular system for data acquisition, monitoring and automation of machinery,
More informationMXPLC. Compact PLC process station. Summary. Application HVAC control systems, data acquisition, interfacing 3 rd party systems.
MXPLC Compact PLC process station Summary The MXPLC is a programmable process station with integrated I/O module with the I/O mix optimized for larger HVAC control applications. The multi-interface process
More informationELSETA IOMOD 8DI8DO. User manual. Elseta V1.0
ELSETA IOMOD 8DI8DO User manual Elseta V1.0 /2017 COPYRIGHTS AND TRADEMARKS Elseta is UAB Aedilis trademark that identifies UAB Aedilis manufactured products. All of the products copyright belongs to "Aedilis.
More informationDatasheet Romod I/O Modules SL
Datasheet Romod I/O Modules SL This library allows you to use Romod I/O devices from the manufacturer Romutec (www.romutec.de) via RS485 COM-Port on supported CODESYS PLC runtimes. The devices can be easily
More information+ (5~27 VDC) GND. Bluetooth V4.2 BLE RS-422/485 Serial Adapter. Model: BLE-485C. 1. Package content: BLE RS-422/485 adapter
Bluetooth V4.2 BLE RS-422/485 Serial Adapter 1. Package content: BLE RS-422/485 adapter Model: BLE-485C Package Contents: BLE 422/485 adapter x 1 Screw x2, Screw nut x 2 A4 User manual x 1 Mini USB Cable
More informationenod4 Weighing controller for automated systems
Titre enod4 Weighing controller for automated systems 1 Presentation What is enod4? enod4 is a weighing module especially designed for integration into an automated system It transforms any strain gauge
More informationCorrection Reissue. Product Discontinuation Notices. Discontinuation Notice of Programmable Controllers CPM1A series and CPM2A series.
PRODUCT NEWS Crection Reissue Product Discontinuation Notices Programmable Controllers Issue Date March 3, 2014 No. 2013041CE(2) Discontinuation Notice of Programmable Controllers CPM1A series and CPM2A
More informationModbus RTU components. for automation in buildings, installations and systems
Modbus RTU components for automation in buildings, installations and systems Module MR-DI4 1108341319 MR-DI10 1108311319 MR-DO4 1108361321 MR-DOA4 110836132101 4 outputs digital (relay) MR-TO4 11083013
More informationisma-b-mg-ip User Manual Global Control 5 Sp. z o.o. Poland, Warsaw
isma-b-mg-ip User Manual Global Control 5 Sp. z o.o. Poland, Warsaw www.gc5.pl Table of content 1 Introduction... 4 1.1 Revision history... 5 1.2 Safety rules... 5 1.3 Technical specifications... 6 1.4
More informationEXD-TEVI Economizer Controller for Tandem Compressors
Technical Bulletin EXD-TEVI is a stand-alone controller for enhanced wet vapor injection for Copeland tandem Scroll compressors in heating applications. Features EXD-TEVI Emerson solution for specified
More informationG0313 Modbus to FF Gateway User Manual
G0313 Modbus to FF Gateway User Manual Microcyber Corporation Caution 1. Please don t take off/install gateway at random. 2. Please check if the power of gateway meets the power request in the User Manual.
More informationDCT 531. Industrial Pressure Transmitter with RS485 Modbus RTU. Stainless Steel Sensor
DCT 5 Industrial Pressure Transmitter with RS85 Modbus RTU Stainless Steel Sensor accuracy according to IEC 60770: : 0.5 % FSO option: 0.5 % FSO Nominal pressure from 0... 00 mbar up to 0... 00 bar output
More informationMillenium 3 logic controllers
Millenium 3 logic controllers Type Part number Power supply Inputs Outputs With display Without display CD12 88970041 24 V c 8 digital (of which 4 are analogue) 4 x 8 A relays 88970042 24 V c 8 digital
More informationBQ351 MODBUS IO DEVICE USER MANUAL
BQ351 MODBUS IO DEVICE USER MANUAL Document Version 1.2.0 Content Content 2 About Device 3 Device Properties 3 Device Layout 4 Sample Connection 6 DIP Switch and Address Settings 7 DIP Switch Modes 7 Supported
More informationWEA-Base. User manual for load cell transmitters. UK WEA-Base User manual for load cell transmitters Version 3.4 UK
WEA-Base User manual for load cell transmitters 1 Contents 1. Technical data... 3 2. Assembly... 4 2.1 Power supply... 4 2.2 Load cells... 4 2.3 RS-485... 4 2.4 Relays... 5 2.5 Digital input... 5 2.6 Analogue
More informationTrident and Trident X2 Digital Process and Temperature Panel Meter
Sign In New User ISO 9001:2008 Certified Quality System Home Products Online Tools Videos Downloads About Us Store Contact Policies Trident and Trident X2 Digital Process and Temperature Panel Meter Products
More informationConto D1 MODBUS COMMUNICATION PROTOCOL
ENERGY METER Conto D1 MODBUS COMMUNICATION PROTOCOL 4/03/15 Pagina 1 di 7 FIRMWARE CONTENTS 1.0 ABSTRACT 2.0 DATA MESSAGE DESCRIPTION 2.1 Parameters description 2.2 Data format 2.3 Description of CRC calculation
More informationUSER GUIDE PEL 8K / PEL 8K-M
V2.0.0 (24.10.2014) 1 (7) COMMISSIONING Mounting - The transmitter should be installed above the measuring point to avoid condensation problems. - The duct overpressure is detected by connecting the measuring
More informationDupline. Data Logger. Types G , G Product Description. Ordering Key G Type Selection. Input/Output Specifications
Dupline Data Logger Types G 800 006, G 800 106 Product Description Programmable channel generator with optional built-in GSM Modem Event and time based data logging functions for digital, analog and counter
More informationIQ3/XNC M-Bus Master
IQ3/XNC M-Bus Master Installation, configuration and error handling Version 2.8b 15. mar. 2011 Electrocom Rødeledsvej 95 DK-5700 Svendborg Denmark Tel : +45 8880 7580 www.electrocom.dk p. 2 1. XNC M-Bus
More informationRTU32S RTU32S Series Small Compact Utility RTU
RTU32S RTU32S Series Small Compact Utility RTU Data Sheet 40270 v1.03 / February 10th, 2013 INTRODUCTION Brodersen Small Compact RTU32S Series with RTU/PLC functionality. The RTU32S series is based on
More informationJazz-J. Jazz. Features:
An All-in-One that is as affordable as a "smart relay" - full-function PLC combined with a textual HMI and keyboard, with up to 40 onboard I/Os Meet the New Jazz 2 series Advantages: Faster performance
More informationE2 Modbus RTU Register Map
Application Note AN ODE 01 E2 Modbus RTU Register Map Author: Peter Evans, Invertek Drives Ltd Revision: 1.02 11 June 2008 Software Version: 1.02 General This document details the Modbus RTU memory mapping
More informationZLJ\YP[`7YVIL, :[HUKHYK
:LUZVY *VU[YVS :LUZVY *VU[YVS (JJLZZ *VU[YVS (JJLZZ *VU[YVS ZLJ\YP[`7YVIL, :[HUKHYK ZLJ\YP[`7YVIL, :[HUKHYK Monitor the physical environment and receive alerts of any disturbances, such as unauthorized
More informationUSR-GPRS User Manual
USR-GPRS232-730 User Manual File Version: V1.0.0.0 Contents USR-GPRS232-730 User Manual...1 Brief Introduction...3 Features...3 1. Get Start...1 1.1. DTU Application...1 1.1.1. Application Diagram...1
More informationCAS Veeder TCP - TLS 300, 350, 450. Gateway
CAS-2700-03 Veeder TCP - TLS 300, 350, 450 Modbus (RTU and TCP) and BACnet and HTML Gateway Description The Veeder TCP Driver allows the Gateway to poll Veeder TLS Panel s for status, real time and configuration
More informationioselect Z-NET Z-SG Bridge Input Isolating I/O Module
-wire Bridge Connection Excitation for to 30 Ω Load Cells 00 Volt (3-way) Isolation Excellent Accuracy (0.0%) DIP Switch Configuration Digital Input Tare Calibration RS8 Modbus RTU Superior Flexible Power:
More informationFlexiSoft Software Release Note
Date: 10 th Nov 2016 Software Version: 2.32 FlexiSoft Software Release Note RN-SW-V2.32 1. New Software Version: FlexiSoft version 2.32 is now available. You can download it from our website using following
More informationGateway MODBUS-to-Opentherm MB-OTG Technical manual. Revision 1 SETECNA. Rel. Date 1 14/09/2016. Page: 1 di 10. Rev /09/2016
Page: 1 di 10 Gateway MODBUS-to-Opentherm MB-OTG Revision 1 Rel. Date 1 Page: 2 di 10 Table of Contents 1 Introduction... 3 2 Installation... 4 3 Integration... 5 3.1 Communication to the MODBUS, Parameter
More informationPT2060 Monitor. PT2060/91 SIM System Interface Module. Specifications. Electrical. Messtechnik
PT2060/ System Interface Module ProvibTech s PT2060/ module is a communication and system interface module. This module is used to: module. The two phase reference channels can be used to provide phase
More informationBrewTroller Phoenix. Owners Manual. Updated - March 14, 2016 BREWTROLLER PHOENIX 1
BrewTroller Phoenix Owners Manual Updated - March 14, 2016 BREWTROLLER PHOENIX 1 2016 BrewTroller All Rights Reserved. Product warranty or service will not be extended if: (1) the product is repaired,
More informationWiFi to RS-422/485 adapter user manual
WiFi to RS-422/485 adapter user manual WiFi to RS-232 adapter Package Contents: WiFi RS-422/485 adapter x 1 2 dbi dipole antenna x 1 A4 User manual x 1 USB Cable x 1 White Box Dimension: 11 x 6 x 5 (cm)
More informationTM172PBG42R Modicon M172 Performance Blind 42 I/Os, Ethernet, Modbus
Product data sheet Characteristics TM172PBG42R Modicon M172 Performance Blind 42 I/Os, Ethernet, Modbus Product availability : Stock - Normally stocked in distribution facility Price* : 427.58 USD Main
More informationThis is the procedure to use the Clone module as a serial converter: To enable communication you must set the following parameters in the drive.
AC10 Clone module 1002-00-00 There are a number of different ways in which the Clone Module can be used with AC10 drive. It can be used to Clone a drive or it can be used as a USB to serial converter to
More information