SMARTSTART MOTOR STARTERS
|
|
- Oswin Peter Golden
- 6 years ago
- Views:
Transcription
1 SMARTSTART MOTOR STARTERS MCG 1
2 AT A GLANCE Covers all line voltages from V AC, single or three phase Transformer supplies a 24V AC coil voltage, no matter the line voltage 12V AC/DC - 250V AC/DC still accepted for outside control signal Wide overload range: 1-40A (up to 30HP at 480V AC line voltage) 2 Standard start/stop and remote (HOA) Pilot lights included True line-in and load-out installation Easy integration of remote and automation components Life-time technical support MCG 400 NW. ENTERPRISE DR. (2ND FLOOR), PORT SAINT LUCIE, FL
3 MCG SMARTSTART INDUSTRIAL STARTERS One starter. One part number. One solution. All-inclusive starter that reduces inventory by eliminating the need to purchase loose components. SMARTSTART Control Module integrates wide range overload, up to 600V AC voltage input, keypad, and automation I/O WHAT IS SMARTSTART? The patented SMARTSTART control module is an integrated, seamless solution that incorporates operator control, superior motor protection, and automation system compatibility in a rugged, compact unit. It offers a wide-range overload and an extensive array of automation and control features that vary between models. Some of these features include emergency shutdown, damper or valve control, status (proof of flow), fault and shutdown, and more. The SMARTSTART module also accepts an incoming voltage range from V AC. This is true plug and play; no changing transformers, no messing with terminal blocks. HOW DOES SMARTSTART WORK? SMARTSTART takes an active role in protecting your motor by measuring the motor inrush current and using it to gauge a safe operating range for your motor. In this way it intelligently detects if your motor overload isn t set correctly, protects against locked rotor, cycle fault, stall conditions, and more. The unique functionality of SMARTSTART saves time, labor, and stocking units. It also provides superior motor protection. This is why some of the top manufacturers in America trust SMARTSTART to protect and control their motors. MCG 3
4 SMARTSTART FEATURES RELIABLE AND COST-EFFECTIVE INSTALLATION Power failure reset options Direct V AC connection SmartStart 1-40A electronic protection Automation compatible Integrated keypad with remote Fully compatible with most automation systems Dry inputs - remote run, two external pilot devices, and limit switch input Wet inputs (12-250V AC) - remote run, shutdown Relay output - fault, proof of flow 24V DC output - power actuator Motor Inrush 6-10x FLA Current (amps) Locked Rotor Trip Stall Trip Max Time to Start Trip Wide range of programmable failure modes Pre-select behavior after power failure - restart last mode (no delay), restart with 10 second delay, and restart off FLA Standard Start Curve Start Time (seconds) Locked Rotor Current Motor Never Reaches FLA Typical Motor Stall Current Standard Motor Starting Current 4 MCG 400 NW. ENTERPRISE DR. (2ND FLOOR), PORT SAINT LUCIE, FL
5 INDUSTRIAL START/STOP WITH SMARTSTART MOTOR PROTECTION 30, 200~600V AC, 1-40A, AUTOMATION SYSTEM READY Easy integration into existing automation systems Comprehensive input/outputs for building management systems Reduced installation times Patent-pending motor protection Electronic protection including locked rotor, cycle fault, and maximum time to start FLA calibration indicators - ensures overload is correctly calculated Blackbox fault logging Records last 10 start conditions, including FLA setting, max inrush, run current, time to start, and safety start mode Retrievable in factory Included disconnect* Motor circuit protection disconnect provides short-circuit protection No fuses required Proactive alarms Alarms proactively react to preserve motor when operating out-of-range or during failed start-ups Active monitoring Active current monitoring trips faster than standard inverse trip curves, resulting in superior protection against locked rotor and stall conditions UL type 1, 4, and 3R enclosures Lockable enclosures 3R includes lockable keypad cover *Only for Combination version NEMA Sized MCG 5
6 SPECIFICATIONS Starter Type MCG - Industrial Start/Stop with SMARTSTART Across the line or Full Voltage Non-Reversing NEMA 1, 3R, OR 4 enclosed Voltage range: 3Ø, V AC Amperage range: 1-40A User Interface Start/Stop/Remote keypad with mode LEDs (N1 & 3R), Start/Stop/Remote switch & Run Pilot light (N4) Standard Control Operations Inputs Outputs Operational Environmental V Remote Apply V AC/DC to energize Dry Remote Shutdown Limit Switch Internal Pilot Device External Pilot Device Proof of flow current status Starter Fault Damper/Actuator Power fail modes N.O. Dry Contact Apply V AC/DC to energize N.O. Dry Contact N.O. Dry Contact (N1 & 3R only) N.O. Dry Contact (N1 & 3R only) N.O. Relay Contact Ratings: 110V DC, 0.3A Resistive, 125V DC, 0.5A GP 30V DC, 2.0A Resistive 120V AC 50/60Hz, 0.5A Resistive 125V AC 50/60Hz, 1.0A GP 240V AC 50/60Hz, 0.25A Resistive 24 V DC, 1A maximum Restart last mode, no delay (default) Restart with 10 second delay Restart Off - LED flashes last mode Ambient Operating Temp -5 to 140 F (-20 to 60 C) Ambient Storage Temp -5 to 185 F (-20 to 85 C) Relative Humidity 5% to 95% non-condensing (Nema 1) Motor Protection Adjustment / Description Default Setting Overload Current Setting Range 1-40A Per FLA Overload Trip Class Adjustable: Class 10 or 20, Trip current = 115% of FLA setting Class 10 Cycle Fault Trip if cycle rate exceeds 20 starts/minute Always On Stall Trips within 0.5 seconds (disabled during startup) Always On Smartstart Protection Adjustment / Description Default Setting Current Phase Unbalance Locked Rotor Out of Calibration On/Off Trips within 3 25% current unbalance. *Trip threshold changes to 80% unbalance when switched to Off Trips within 0.5 seconds Trips after 10 seconds if the FLA dial setting is incorrect (set above calculated FLA range), ie. Start current is outside of an acceptable range (fla setting * 5 < inrush < fla setting * 14). On Max Time to Start Regardless of FLA or I2t curve, always trip at start if starting current is outside of an acceptable range (inrush / 5) and still decreasing after 10 seconds. 6 MCG 400 NW. ENTERPRISE DR. (2ND FLOOR), PORT SAINT LUCIE, FL
7 UL TYPE 1 INDOOR ENCLOSURE STANDARD MOTOR STARTER - 3 PHASE, 200~600 V AC Three Phase HP Contactor 200V 230V 460V 600V NEMA Size Part Number MCG1-9/P MCG1-18/P MCG1-32/P P MCG1-40/P40 UL TYPE 1 INDOOR ENCLOSURE COMBINATION MOTOR STARTER - 3 PHASE, 200~600 V AC Three Phase HP Contactor NEMA Part Number 200V 230V 460V 600V Size 3/4 3/4 MCG1-9/P-G /2 1/ MCG1-9/P-G /4 3/ MCG1-9/P-G MCG1-9/P-G MCG1-9/P-G MCG1-18/P-G MCG1-18/P-G MCG1-18/P-G MCG1-32/P-G MCG1-32/P-G MCG1-32/P-G P MCG1-40/P-G40-40 UL TYPE 3R OUTDOOR ENCLOSURE STANDARD MOTOR STARTER - 3 PHASE, 200~600 V AC Three Phase HP Contactor NEMA Part Number 200V 230V 460V 600V Size MCG3R-9/P MCG3R-18/P MCG3R-32/P P MCG3R-40/P-40 UL TYPE 3R OUTDOOR ENCLOSURE COMBINATION MOTOR STARTER - 3 PHASE, 200~600 V AC Three Phase HP Contactor NEMA Part Number 200V 230V 460V 600V Size 3/4 3/4 MCG3R-9/P-G /2 1/ MCG3R-9/P-G /4 3/ MCG3R-9/P-G MCG3R-9/P-G MCG3R-9/P-G MCG3R-18/P-G MCG3R-18/P-G MCG3R-18/P-G MCG3R-32/P-G MCG3R-32/P-G MCG3R-32/P-G P MCG3R-40/P-G40-40 UL TYPE 4 INDOOR/OUTDOOR ENCLOSURE STANDARD MOTOR STARTER - 3 PHASE, 200~600 V AC Three Phase HP Contactor NEMxA Part Number 200V 230V 460V 600V Size MCG4-9/P MCG4-18/P MCG4-32/P P MCG4-40/P40 *Consult factory for NEMA 4X enclosure options MCG1-18/P-G17-40 Diconnect Amperage Overload Rating Contactor Size (9, 18, 32, etc.) Enclosure Rating (Type 1, 3R or 4) UL TYPE 4 OUTDOOR ENCLOSURE COMBINATION MOTOR STARTER - 3 PHASE, 200~600 V AC Three Phase HP 200V 230V 460V 600V 3/4 3/4 Contactor NEMA Size Part Number MCG4-9/P-G /2 1/ MCG4-9/P-G /4 3/4 2 3 MCG4-9/P-G MCG4-9/P-G MCG4-18/P-G MCG4-18/P-G MCG4-18/P-G MCG4-18/P-G MCG4-32/P-G MCG4-32/P-G MCG4-32/P-G P MCG4-40/P-G40-40 MCG 7
8 MCG (1/3R) WIRING SCHEMATICS ISS(1/3R) CONTROL WIRING Remote Run Voltage Inputs Shut Down VAC/DC Input VAC/DC Input ISS STARTER POWER WIRING FLA (A) Overload Setting Relay Outputs Status Common Fault OL Keypad PCB Power Pilot Devices Dry Input Actuator Control Contactor Coil Start Remote Remote Run Motor Limit Switch A1 A2 Normally Closed Input Normally Open Input Normally Open Input 24VDC, 1A Output Normally Open Input M 24V Output to contactor coil MCP (Optional) H1 H VAC Input L1 L2 L3 M T1 T2 T3 AUX CONT MTR H1 H4 3PH UL TYPE 1 DIMENSIONS All dimensions are in inches 7 5/8 13 9/ /8 6 3/8 8 1/16 UL TYPE 3R DIMENSIONS All dimensions are in inches 7 5/8 13 9/ /8 6 3/8 8 1/16 8 MCG 400 NW. ENTERPRISE DR. (2ND FLOOR), PORT SAINT LUCIE, FL
9 MCG4 WIRING SCHEMATICS ISS4 CONTROL WIRING POWER WIRING Remote Run Voltage Inputs Shut Down VAC/DC Input VAC/DC Input FLA (A) Keypad PCB Power Overload Setting Relay Outputs Pilot Devices Dry Input Actuator Control Contactor Coil Start Remote Remote Run Motor Limit Switch A1 A2 Status Common Fault STOP START REMOTE G Normally Open Input Normally Open Input M X A+ A- 24V Output to contactor coil X 24VDC, 1A Output MCP (Optional) OL H VAC Input L1 H4 L2 L3 M T1 T2 T3 AUX CONT MTR 3PH H1 H4 UL TYPE 4 DIMENSIONS All dimensions are in inches NON-COMBINATION* 10 7/16 7 MTG. 12 5/16 11 MTG. COMBINATION* 6 11/16 7 5/8 6 11/16 8 3/8 *Consult factory for NEMA 4X enclosure options *Combination dimensions are the same as non-combination dimensions except for the depth (shown above, 8 5/8 ). MCG 9
10 MCG offers a wide variety of industrial control and automation products as well as custom-built lighting contactors, enclosures, and motor starters. Flexibility allows MCG to create custom solutions for virtually any application. 10 MCG 400 NW. ENTERPRISE DR. (2ND FLOOR), PORT SAINT LUCIE, FL
11 MCG 11
12 400 NW. ENTERPRISE DR. (2ND FLOOR) PORT SAINT LUCIE, FL MCG 400 NW. ENTERPRISE DR. (2ND FLOOR), PORT SAINT LUCIE, FL A DIVISION OF
Smartstart Control Module
Smartstart TECHNOLOGY What is Smartstart? The patented Smartstart control module is an integrated, seamless solution that incorporates operator control, superior motor protection, and automation system
More informationIPS INTELLIGENT PUMP STARTER
IPS INTELLIGENT PUMP STARTER The IPS Intelligent Pump Starter features SMARTSTART motor protection, integrated electronic pump protection overload, and power metering and data logging options. Ø & Ø, 0/60
More informationEMS 1Ø, 120 ~ 230V, 1/10-25HP 3Ø, 200 ~ 600V, 1/2-300HP
ES, 120 ~ 230V, 1/10-25HP, 200 ~ 600V, 1/2-300HP ENERGY ANAGEENT STARTER T Smartstart THE OST INTELLIGENT STARTER YET Power metering, optional BACnet or odbus communications, and an intuitive interface
More informationENERGY MANAGEMENT SOFT-STARTER THE MOST INTELLIGENT SOFT-STARTER YET
ES-RV 3Ø, 208 ~ 480V, 2-250HP ENERGY ANAGEENT SOFT-STARTER THE OST INTELLIGENT SOFT-STARTER YET Retaining the incredible features from the original ES such as Power metering & odbus RTU communications,
More informationFRANKLIN CONTROL SYSTEMS HVAC SMART STARTERS
FRANKLIN CONTROL SYSTES HVAC SART STARTERS BUD CLARK COONS Location: Portland, OR FCS Product: ES Starters YOU LL FIND FCS STARTERS IN THE WORLD S SARTEST PROJECTS. Project Spotlight: Bud Clark Commons
More informationQ-LINK SMART BYPASS. SIZING INFORMATION TABLE Q-Link Variable Frequency Drive - 3-Phase 208 VAC 230 VAC VAC HP FLA HP FLA HP FLA TECHNOLOGIES
Q-LINK SMRT BYPSS 1 28, 208 480VC, 3Ø UL Type 1 Enclosure The is an integrated solution for critical applications without compromising for communications and motor protection. Unlike traditional bypasses,
More informationPump Data Sheet - Patterson HVAC Pumps Company: Intermountain Hydron Name: Cache County Mountain Crest Date: 09/24/2018
Pump Data Sheet - Patterson HVAC Pumps Company: Intermountain Hydron Name: Cache County Mountain Crest Date: 09/24/2018 Tags: P-8 1800RPM Premium Efficient Motor 460/3/60 Pump and Motor Weight: 183lbs
More informationSED2 Variable Frequency Drives with Electronic (E) Bypass Options
SED2 Variable Frequency Drives with Electronic (E) Options Description The E- Options are companion packages for the family of SED2 Variable Frequency Drives (s). For information on the family of SED2
More informationMODELS DPDT DPDT DPDT-60MS DPDT-60MS
INSTALLATION INSTRUCTIONS Revision B1 Rapid City, SD, USA, 03/2010 MODELS 201-100-DPDT 201-200-DPDT 201-100-DPDT-60MS 201-200-DPDT-60MS II_201-XXX-DPDT_B1 II-201-DPDT-B BE SURE POWER IS DISCONNECTED PRIOR
More informationOVERLOAD RELAYS POWER & ACTUATION PROVEN. series
POWER & ACTUATION OVERLOAD RELAYS series Need reliable, accurate overload and phase-loss protection for your motors? c3controls Series Bimetallic Overload Relays provide unmatched protection and can be
More informationQuantum III. Compact DC Drive Package. Slitter DC Drive Package. Quantum III
Compact DC Drive Package The delivers a DC drive package that integrates the intelligence of the Mentor II with a space saving design that incorporates many accessories typically required in the North
More informationPHASE MONITOR RELAYS Product Summary
Product Summary Phase Monitor Relays provide protection against premature equipment failure caused by voltage faults on 3 Phase systems. All Macromatic Phase Monitor Relays are designed to be compatible
More informationInstallation, Operation and Maintenance Manual
Document 481200 VGD-100 Vari-Green Drive Installation, Operation and Maintenance Manual Please read and save these instructions for future reference. Read carefully before attempting to assemble, install,
More informationSECTION SOLID-STATE REDUCED VOLTAGE STARTERS
SECTION 26 29 13.16 PART 1 - GENERAL 1.1 THE REQUIREMENT A. General: The CONTRACTOR shall provide solid-state reduced voltage motor starters, complete and operable, in accordance with the Contract Documents.
More informationQuick Start Guide TS A
Quick Start Guide TS 930 125-630A DANGER HAZARD OF ELECTRICAL SHOCK, EXPLOSION, OR ARC FLASH Read and understand this quick start guide before installing and operating the transfer switch The installer
More informationBT300 HVAC Drives Electronic Bypass (E-Bypass) Options
BT300 HVAC Drives Electronic Bypass (E-Bypass) Options Description The BT300 Electronic Bypass (E-Bypass) Options are companion packages for the family of BT300 Variable Frequency Drives (VFDs). For information
More informationSED2 Variable Frequency Drives Conventional Bypass (C-Bypass) Options
Submittal Sheet SED2 Variable Frequency Drives Conventional Bypass (C-Bypass) Options Description The Bypass Options are companion packages for the family of SED2 Variable Frequency Drives. For information
More informationS.W. Version SubMonitor Connect Installation & Operation Manual
S.W. Version 7.003 SubMonitor Connect Installation & Operation Manual Safety Instructions As with all electrical products, read the manual thoroughly before operating. Only qualified personnel should
More information3RM1 Hybrid Starters 6SIRIUS. contents. Industrial Controls Product Catalog 2017
3RM1 Hybrid Starters Industrial Controls Product Catalog 2017 Section contents 3RM1 Compact - Hybrid Starters Overview /2 General Data /3 Selection and ordering data /4 Accessories /5 - /9 Technical Data
More informationMODERNIZE YOUR DC CRANES. Convert Your DC Controls to State-of-the-Art Energy Efficient OmniPulse DDC Series 2 Drives
TM MODERNIZE YOUR DC CRANES Convert Your DC Controls to State-of-the-Art Energy Efficient OmniPulse DDC Series 2 Drives Magnetek, the leader in digital power and motion control systems, brings you the
More informationStandard Options. Model 4100 Position Indicating Meter. Three Phase Motor Control. Positran Transmitter
Standard Options Model 4100 Position Indicating Meter A percent-of-full-travel meter is supplied with a trim potentiometer resistor, terminal block and connectors. A potentiometer is required in the actuator
More informationGE Power Management. MMII Intelligent MCC Controller
A concept that will offer reduced overall installed cost and production efficiency through information availability to operators and maintenance. Presentation Overview 6 Applications 6 Protection and Control
More informationControls Enclosed Non-Combination Starters - PESW Series
NEMA 4/4X Non Metallic Enclosure Product Features WEG offers non-reversing and non-combination NEMA-4X magnetic starter up to 75HP at 460V. Featuring components that meet IEC design standards and UL horsepower
More informationSED2 VFD NEMA Type 3R Bypass/Air Conditioner
SED2 VFD NEMA Type 3R Bypass/Air Conditioner Description The NEMA Type 3R Bypass with Air Conditioner allows SED2 to be employed in a harsh environment. The SED2 is designed specifically for HVAC applications
More informationJK Series POWER DISTRIBUTION. Solid State Starters Medium Voltage A
POWER DISTRIBUTION JK Series Solid State Starters Medium Voltage 200-400-600-720A SOLID STATE STARTER JKSSS4+ Series The JKSSS Series of motor starter is the result of extensive research and development.
More informationSP SP-T-9
INSTALLATION INSTRUCTIONS Revision B1 Rapid City, SD, USA, 04/2010 MODELS 201-100-SP 201-200-SP 201-200-SP-T-9 II_201-SP_B1 2880 North Plaza Drive, Rapid City, South Dakota 57702 (800) 843-8848 (605) 348-5580
More informationTECHNICAL BROCHURE BCPNEMAST R0. NEMA Rated Three-Phase Starters BY EATON
TECHNICAL BROCHURE BCPNEMAST R0 NEMA Rated Three-Phase Starters BY EATON STANDARD FEATURES Series ECN - NEMA Rated Three-Phase Starters Adjustable Electronic Overloads C440 Series - Adjustable Class, Bi-metallic,
More informationPowered to Perform. Everyday Reliability. Exceptional Value. Expertise and Support
A decentralized solution. Many drive applications utilize control panels with complex wiring taking up large amounts of space. These control panels are often mounted away from the application requiring
More informationFor normal duty, design the VFD voltage level at 480 Volt, 3 Phase, 60 Hertz. (In Canada, 600 Volt, 3 Phase, 60 Hertz.)
Introduction The Variable Frequency Drive Design Guidelines provides design criteria and specifications used in the procurement and application of variable frequency drives (VFDs). Table of Contents 1.
More informationTable of Contents 1. Overview Installation...6
(2003-01-31) Table of Contents 1. Overview...1 1.1. Introduction... 1 1.2. Product Description... 1 1.2.1. Mechanical Actuator Assembly with M2CP Electrical Enclosure... 1 1.2.2. Variable Frequency Controller
More informationSED2 Variable Frequency Drives
SED2 Variable Frequency Drives Startup Procedure and Checklist Document No. 155-718 Table of Contents Prerequisites...1 Preparing for SED2 VFD Startup...1 HVAC Startup Procedure for SED2 with Bypass Option...4
More informationMini Contactors & Overloads
108 Mini s & Overloads GMC-12M Surface or DIN rail mountable UL508 compliant 1/ to 7-1/ 50/60Hz AC and DC versions available Direct-mounting overloads RoHS compliant Auxiliary contacts standard (1 N.0.)
More informationRFD-200 TM. Test a Wide Variety of Relays in their Outdo FEATURES AT A GLANCE. Auxiliary AC/DC Power Supply. RFD-200 S2 Ampere Meters
Ergonomic Design a Make Performance RFD-200 TM Vanguard s Model RFD-200 S2 is a portable relay test set that delivers performance verification testing of electromechanical, electronic, and microprocessorbased
More informationEnclosed DOL Motor Starter Type 4x, Plastic, 3-Phase
Enclosed DOL Starter Type x, Plastic, Phase C US LISTED ENCLOSED INDUSTRIAL CONTROL PANEL WIRING SPECIFICATIONS CONTROL/COIL VOLTAGE: LINE (LINE) START/STOP (STSR) START STOP //8 //8 Customer Supplied
More informationSED2 Variable Frequency Drives
Building Technologies SED2 Variable Frequency Drives More standard features Means better control of HVAC applications The global leader in Heating, Ventilation and Air Conditioning (HVAC) products and
More informationVariable Frequency Drive Design Guidelines
Variable Frequency Drive Design Guidelines The Variable Frequency Drive Design Standard provides design criteria and specifications used in the procurement and application of variable frequency drives
More informationLM10 to MM200 Retrofit
Grid Solutions LM10 to MM200 Retrofit Replace old LM10 Motor Controller relays with the Multilin TM MM200 Motor Management System The LM10 Motor Controller (discontinued in 2013) has been replaced by new
More informationTable of Contents. Safety. Attention. Warnings
Solstart Miniature Soft Starter 8-58A, 220-600V Instruction Manual Ver. 21.2. 2002 Table of Contents Page Subject 3 Starter Selection 4 Installation Notes 5 Wiring 6 Starter Settings & Start-up Procedure
More informationSLI 15 Inverter Series Data Sheet 1500 Watt, 1U Compact Inverters
Applications Telecom IT Industrial Safety in compliance with IEC60950:1999, 3 rd edition; EN60950:2000; UL60950, 3 rd edition; CSA Standard C22.2 No.60950-00, 3 rd edition Features New, compact design:
More informationThe PCI Series. Precise power control for complex SCR applications. Phase Angle Fired SCR Power Controls AMPS VAC
The PCI Series Phase Angle Fired SCR Power Controls 25-1200 AMPS 120-600 VAC Precise power control for complex SCR applications. ROBICON 1996 Distributed Worldwide by www.mcgoff-bethune.com Applications
More informationJockey Pump Controllers
BR081001EN Microprocessor Based with Color Touchscreen Product Description ACROSS THE LINE Controllers operate across-the-line. Full voltage is applied to the motor for starting by the use of a single
More information29 $ Manual Motor Starters FREESHIPPING. MOTOR CONTROLS 25. Features: MMS-32H Frame. MMS-63H Frame.
www.factorymation.com/motorcontrols MOTOR CONTROLS 25 Manual Motor Starters High interrupt capacity Din rail and surface mounting Lockable handle (OFF position) IP20 finger safe terminals Class 10 thermal
More informationEnclosed Non-Reversing Combination Controller, AC Operation - Type 1/12K/IP66 ➏➐. Non-Metallic Type 1/12K/IP66 Enclosure (KS7-C0C4R)
KWIKstarter/CX7 CX7 Non-Reversing Combination Controller, AC Enclosed Non-Reversing Combination Controller, AC Operation - Type 1/12K/IP66 ➏➐ Catalog Number ➍➏➑➒ ~ ~ ~ ~ 0.10 0.16 2.1 1 CX7-9-10- -AS0.16A-A10-PG
More informationINTEGRATED AUTOMATION ACTUATORS AND OPERATORS
25 34 13.13 - PART 1 - GENERAL 1.1 THE REQUIREMENT A. The CONTRACTOR shall provide complete Valve Actuators and Operators as shown on the drawings, control diagrams, herein, or in other Sections of the
More informationSS2200 Remote Controller
SS2200 Remote Controller General Purpose, DC Voltage General The SS2200 Remote Controller is a microprocessor-based programmable controller specifically designed to control single line and dual line centralized
More informationVLT 2800 DRIVE SPECIFICATIONS
VLT 2800 DRIVE SPECIFICATIONS Drive Input Power Input voltage 3 phase... 200 through 240, or 380 through 460; 3-phase all ratings 200 through 240, 1-phase through 2 HP Input voltage range for full output...
More information12-36 VDC/12-24 VAC Power Option 4-Digit Display, 0.56 (14.2 mm) or 1.20 (30.5 mm)
4-20 ma & Relay Output Features 4-20 ma, ± 10 V, TC & RTD Inputs 12-36 VDC/12-24 VAC Power Option 4-Digit Display, 0.56 (14.2 mm) or 1.20 (30.5 mm) 24 VDC @ 200 ma Transmitter Power Supply Options Type
More informationIMS Control & EPR, We keep your motors running ABB s new control & protection devices up to 18.5 kw / 20 hp
IMS Control & EPR, 2010 01 29 We keep your motors running ABB s new control & protection devices up to 18.5 kw / 20 hp October 27, 2010 1SBC101089D0201 ABB s new control and protection devices Up to 18.5
More informationIndustrial Electric Actuators AC and DC Voltages Nm/ inch lbs
Industrial Electric Actuators AC and DC Voltages 30-200Nm/265-1770 inch lbs Features Quarter turn (90 ) operation with mechanical travel stops Type 4X/IP67 weatherproof aluminum alloy enclosure Highly
More informationSet up and verify the operation of basic motor starters. Understand the purpose of a separate control circuit.
Exercise 3-1 Motor Starters EXERCISE OBJECTIVE Set up and verify the operation of basic motor starters. Understand the purpose of a separate control circuit. DISCUSSION OUTLINE The Discussion of this exercise
More informationQCPort Cover Control Trouble Shooting Guide
QCPort Cover Control Trouble Shooting Guide Technical Document Feb. 2006 Page 1 of 14 QCPort Cover Control Description Door Defeater Address/Options Bucket Latch Breaker Actuator Hasp Lock Keypad Overlay
More informationSORDS ELECTRIC ~ MA7200. Sensorless Vector AC Inverter.
www.sordselectric.com MA7200 Sensorless Vector AC Inverter Features and Benefits Sensorless Vector The MA7200 has precise speed and torque control for the most demanding system performance and simple set-up
More informationPowerFlex 400 AC Drive Guide Specification
PowerFlex 400 AC Drive Guide Specification Adjustable Frequency Drives with Bypass 3.0 50HP @ 208V AC 3.0 350HP @ 480V AC PART 1 GENERAL 1.01 Quality Assurance A. The manufacturer shall have minimum 5
More informationFor full product information, visit Use the SpeedSpec code or scan the QR Code for quick access to the specific web page.
R Safety Monitoring Relays For full product information, visit www.sti.com. Use the SpeedSpec code or scan the QR Code for quick access to the specific web page. Dual-Channel Safety Monitoring Relay Power
More informationAPPLICATION CONTROL GUIDELINES. IntelliROL Power Supply PN Revision Date: March 15, 2017
APPLICATION CONTROL GUIDELINES IntelliROL Power Supply PN 1176718 Revision Date: March 15, 2017 Table of Contents List of Tables...3 TGW Safety Recommendation...4 Warnings and Safety Instructions...5 Introduction...6
More informationInstallation, Operation, and Service Manual SIEMENS HEALTHCARE INTEGRATED ELECTRICAL CABINET
Technical Publications SIEMENS HEALTHCARE INTEGRATED ELECTRICAL CABINET for ARTIS Q / Q.ZEN / ONE ARTIS ZEEGO / ZEEGO.ZEN ARTIS ZEE MULTIPURPOSE SINGLE PLANE IECAX480V125A Main Disconnect Panel Bevco Engineering
More informationPC-200-LLC-GM INSTALLATION INSTRUCTIONS. Revision A1 Rapid City, SD, USA, 10/2009 II_PC-XXX-LLC-GM_A1
INSTALLATION INSTRUCTIONS Revision A1 Rapid City, SD, USA, 10/2009 MODELS PC-100-LLC-GM PC-200-LLC-GM II_PC-XXX-LLC-GM_A1 2880 North Plaza Drive, Rapid City, South Dakota 57702 (800) 843-8848 (605) 348-5580
More informationETM MD100 Drive System 1/2HP (370W) User Manual. Table of Contents. Drive Features
Table of Contents Drive Features... 1 Drive Specifications... 2 Certifications... 3 Installation - Drive Dimensions... 3 Motor Dimensions (mm)... 4 Drive Mounting... 4 Wiring... 5 I/O Terminals... 9 Menu...
More informationCompact Electric Actuators AC and DC Voltages 18 Nm/160 inch lbs
Compact Electric Actuators AC and DC Voltages 18 Nm/160 inch lbs Features Miniature industrial quality quarter turn (90 ) rotation Excellent power to size ratio only 4.6 H x 3 D Type 4X and IP67 weatherproof
More informationESC 201. Installation and Operating Instructions Manual. SG Jan 2015
ESC 201 Installation and Operating Instructions Manual SG-0002-03 Jan 2015 Table of Contents 1.0 FUNCTIONS... 5 2.0 FEATURES... 5 3.0 ESC 201 DESCRIPTION... 6 4.0 GENERAL OPERATIONS... 6 4.1 MANUAL MODE
More informationALTERNATING RELAYS & CONTROLLERS ARM Series
ALTERNATING RELAYS & CONTROLLERS ARM Series Process Control Equipment for Hazardous Locations 7M26 UL913 INCLUDES INTRINSICALLY SAFE INPUTS Integrated Duplex Controller SOSO Operation (Sequence-on, Simultaneous-off)
More informationFX 2 Instruction Manual
FX 2 Instruction Manual Climma Compact Version Annapolis MD USA 301 352 6962 info@veco-na.com Introduction: The FX2-DX digital controller operates onboard air conditioning equipment to provide room temperature
More informationJockey Pump Controllers
BR081001EN Microprocessor Based with Color Touchscreen Product Description ACROSS THE LINE Controllers operate across-the-line. Full voltage is applied to the motor for starting by the use of a single
More information9/7/2010. Chapter , The McGraw-Hill Companies, Inc. MOTOR SYMBOLS. 2010, The McGraw-Hill Companies, Inc.
Chapter 2 MOTOR SYMBOLS 1 Symbols are used to represent the different components of a motor control system. Symbols sometimes look nothing like the real thing, so we have to learn what the symbols mean.
More informationMODELS: STEAM FIRED YPC-ST-14SC & YPC-ST-16SL Thru YPC-ST-19S
Supersedes: 155.19-W1 (407) Form: 155.19-W1 (812) TWO-STAGE ABSORPTION CHILLERS WIRING DIAGRAMS CONTRACTOR ORDER NO. JCI CONTRACT NO. JCI ORDER NO. PURCHASER JOB NAME LOCATION ENGINEER REFERENCE DATE APPROVAL
More informationPHASETRONICS. SCR Power Control Specialists. EP1 Series Power Control Single Phase SCR Amps OPERATION & SERVICE MANUAL
PHASETRONICS Specialists EP1 Series Power Control Single Phase SCR 10-50 Amps OPERATION & SERVICE MANUAL Phasetronics, Inc. P.O. Box 5988 1600 Sunshine Drive Clearwater, FL 33765 (727)573-1900 FAX(727)573-1803
More informationMetering Devices, Protective Relays, Software and Connectivity. Pre-Wired Control Power, Voltage and CT Inputs
.3 Features and Benefits Saves installation time and cost One part number to order; no need to worry that any part has been left out Pick the meter or meters you need as it is designed to fit various Eaton
More informationC. New or replacement products installed in existing facilities shall be consistent with existing equipment.
September 2012, rev 00 26 2923 Variable Frequency Controllers PART 1. GENERAL 1.01 Description A. This specification is to cover a complete Variable Frequency motor Drive (VFD) consisting of a pulse width
More informationTrident and Trident X2 Digital Process and Temperature Panel Meter
Sign In New User ISO 9001:2008 Certified Quality System Home Products Online Tools Videos Downloads About Us Store Contact Policies Trident and Trident X2 Digital Process and Temperature Panel Meter Products
More information4/8/ nd Annual OTCO WW Workshop W/WW Product Overview ACQ550. ABB Slide 1
4/8/2015 52 nd Annual OTCO WW Workshop W/WW Product Overview ACQ550 Slide 1 Drive Basics Why Use Adjustable Speed Drives? Reduced Energy Consumption Improved Process Control / Efficiency Increased Product
More information24973 Circuit Breaker MINIATURE CIRCUIT BREAKER, 440VAC, 10A, CIRCUIT BREAKER TYPE: STANDARD
United States 24973 Circuit Breaker MINIATURE CIRCUIT BREAKER, 440VAC, 10A, CIRCUIT BREAKER TYPE: STANDARD Image not available Product Information Features and Specifications Approvals: IEC 60947-2 Rated
More informationPG Softstarter Installation Manual for 5A, 9A and 16A Controllers
PG Softstarter Installation Manual for 5A, 9A and 16A Controllers Important User Information The examples and diagrams in this manual are included solely for illustrative purposes. Because of the many
More informationEasy To Use OEMS Take Note
MA7200 Features Sensorless Vector Precise speed and torque control for the most demanding system performance. Simple set-up through autotuning function. The MA7200 can be operated in sensorless vector
More informationINSTALLATION INSTRUCTIONS. Revision C1 Rapid City, SD, USA, 02/2010 MODEL ALT-XXX-3-SW
INSTALLATION INSTRUCTIONS Revision C1 Rapid City, SD, USA, 02/2010 MODEL ALT-XXX-3-SW II-ALT-XXX-3-SW-B BE SURE POWER IS DISCONNECTED PRIOR TO INSTALLATION! FOLLOW NATIONAL, STATE AND LOCAL CODES. READ
More informationMAJOR VA Power Inverter
MAJOR500-500 VA Power Inverter The Major500 is a highly reliable, telecom quality, DC to AC power inverter. The Major500 features full electronic protection, high efficiency and low output noise. The built-in
More informationSLI 15 INVERTER SERIES, 1500 W
SLI 15 INVERTER SERIES, 1500 W FEATURES DESCRIPTION New, compact design: 1U height x 19" width x 14.94" depth; 19" rack-mountable High efficiency: up to 93% True sine wave output Parallelable output with
More informationTeSys IEC Contactors and Overload Relays
TeSys IEC Contactors and Overload Relays Making High-Fault Short-Circuit Current Ratings Simple Schneider Electric is an industry leader in IEC contactors and overload relays, and is recognized as the
More informationThe easy to use three-phase digital DC drive for regenerative and non-regenerative applications from HP
Digital DC Drives The easy to use three-phase digital DC drive for regenerative and non-regenerative applications from 1.5-600 HP The FlexPak 3000 digital DC drive features a unique ergonomic user interface
More informationPLT. Breaker-based transfer switch open, closed or soft transition amps. Specification sheet
Specification sheet PLT Breaker-based transfer switch open, closed or soft transition 800 3000 amps Description PLT breaker-based transfer switches are designed for operation and switching of electrical
More informationADJUSTABLE SPEED DRIVES. Q9 Series
ADJUSTABLE SPEED DRIVES Q9 Series Reliable & Configurable Reliable Toshiba has manufactured pulse-width modulated drives since 1981 and is one of the few companies that manufactures both motors and drives
More informationIntelligent Technologies
Intelligent Technologies QCPort Starter Network Adapter Product (QSNAP) Installation and User Manual Publication No. MN05001001E New Important Notice Please Read The product discussed in this literature
More informationWiring Diagrams UNITS WITH STARTING SERIAL NUMBER 3507Q
AQUASNAP 30RB060-390 Air-Cooled Liquid Chillers with COMFORTLINK Controls 60 Hz Wiring Diagrams UNITS WITH STARTING SERIAL NUMBER 3507Q INDEX* POWER SCHEMATICS 30RB Unit Size Voltage Figure Number Label
More informationPEAKTRONICS DHC-100 FEATURES. Digital High-Resolution Controller
PEAKTRONICS The Peaktronics is a high performance digital positioner intended to control AC actuators, providing 450 points of resolution with quarter turn actuators ranging from sec to 0 sec and rated
More informationInstallation Manual Updated May 2017
Code No. LIT-12012114 Installation Manual Updated May 2017 JC-VSD Factory Packaged (FP) Series II drive frames 4 8, Type 1 and 3R Johnson Controls variable speed drives Disclaimer of warranties and limitation
More informationFlomatic Smart Card TM Model FDHC-100 (Digital High-Resolution Controller) Configuration and Operation Manual
The Flomatic FDHC-100 is a high performance Digital positioner intended to control AC actuators, providing 450 points of resolution with quarter turn actuators ranging from 2 sec to 120 sec and rated for
More informationVersatile Safety Interlock Switch with Guard Door Locking
R Conforms to EN1088, EN60947-5-1, EN292, EN60204-1 UL and C-UL listed, BG approved Versatile Safety Interlock Switch with Guard Door Locking High locking force of 450 pounds locks guard door shut until
More information920 Remote Control (RC) Switches
920 Remote Control (RC) Switches ASCO is the global leader in power switching and controls ASCO 920 PRODUCT SPECIFICATIONS SWITCH ONLY (PANELBOARD MOUNTING) 1,2,3 () DIMENSIONS, IN.(MM) WIDTH HEIGHT DEPTH
More informationEnclosed Non-Reversing Combination Controller, AC Operation - Type 1/12K/IP66 ➏➐ (KS7-C0C4R) Discount Schedule F-1
KWIKstarter/CX7 CX7 Non-Reversing Combination Controller, AC Enclosed Non-Reversing Combination Controller, AC Operation - Type 1/12K/IP66 ➏➐ ~ ~ ~ ~ 0.10 0.16 2.1 1 CX7-9-10- -AS0.16A-A10-PG 551 Q4 ~
More informationCompact Coded Magnetic Safety Interlock Switch and Control Units
C Conforms to EN292, EN60204-1, EN954-1, EN1088, EN60947-5-3, EN947-5-3, EN50081, EN50082, EN61000-6-2 UL and C-UL listed, TUV certified Description R US Compact Coded Magnetic Safety Interlock Switch
More informationPower supplies CP-E, CP-S and CP-C range NEW! CP-E Range
Power supplies CP-E, CP-S and CP-C range CP-E Range The new CP-E range power supplies M odern switch mode AC to DC power supplies are a vital component in most information gathering systems, energy management,
More informationLED indicators for normal/fault operating conditions, setup mode, loss of analog signal, and solid-state motor control output.
INTRODUCTION The Digital Futronic module uses the latest integrated microcontroller technology to enable one electronics module to perform valve actuator modulating and positioning control from analog
More informationSED2 VFD NEMA Type 3R and 3R Harsh Environment (3RHE) Bypass Operating Instructions
SED2 VFD NEMA Type 3R and 3R Harsh Environment (3RHE) Bypass Operating Instructions Item Number 125-3377, Rev. FA SED2 VFD NEMA Type 3R and Type 3R Harsh Environment (3RHE) Bypass Operating Instructions
More informationMagnetic Circuit Protectors 153. Multi-Pole Circuit Protectors 154. APL/UPL, 205/295 Barriers 155. Configurations 156. Operating Characteristics 158
Magnetic Circuit Protectors 53 Multi-Pole Circuit Protectors 54 APL/UPL, 205/295 Barriers 55 Configurations 56 Operating Characteristics 58 Delay Curves 59 Specifications 64 APL/UPL Decision Tables 70
More informationSIEMENS HEALTHCARE INTEGRATED ELECTRICAL CABINET
Product Data Sheet Technical Publications SIEMENS HEALTHCARE INTEGRATED ELECTRICAL CABINET for ARTIS Q / Q.ZEN / ZEE BIPLANE IECAX480V225A Main Disconnect Panel Bevco Engineering Company, Inc. CONFIDENTIAL
More informationZC Series Zone Monitoring Controllers
ZC Series Zone Monitoring Controllers Installation Instructions MANUAL Reset Controllers Model Description Part Number ZC-1 1 Zone Controller 0421 ZC-2 2 Zone Controller 0422 ZC-3 3 Zone Controller 0423
More informationSR489 SR489. Generator Management Relay. Economical protection, metering, and monitoring functions for small and medium sized generators.
SR489 Generator Management Relay Economical protection, metering, and monitoring functions for small and medium sized generators. 1 Product Highlights Inputs / Outputs Generator Protection Power Metering
More informationICS Regent. Relay Output Modules. Low Power and High Power (T3446L and T3446H) PD-6017
ICS Regent PD-6017 Relay Output Modules Low Power and High Power (T3446L and T3446H) Issue 1, March, 06 Relay output modules provide control of eight user output loads. Two types of relay output modules
More informationCapacitor Switching Contactors
Capacitor Switching Contactors Types K3-..A.. and K3-..K.. Ideal for Power Factor and Harmonic Filter Systems Features that matter Patented design with significant damping of inrush current Long life tested
More information160 AA02SF1 AF DS-D17
Ordering Instructions The Standard Packaged Drive Program allows users to create drive packages based on their specific needs. A complete drive package may be specified by assembling a single catalog number
More informationFire Pump Controllers Jockey Pump Controllers
Fire Pump Controllers Jockey Pump Controllers Jockey Pump Controllers 1.7 Jockey Pump Controllers XTJP Jockey Pump Controllers - Feature Sheet... XTJP Dimension Drawings... XTJP Wiring Diagrams - 3 Phase...
More information