Data Sheet Rev DALLIS Serial Data
|
|
- Arron Owen
- 6 years ago
- Views:
Transcription
1 Lawo AG, Germany Phone: Web: Data Sheet Rev DALLIS Serial Data Port serial multi-format data converter 9/ Serial Data bidirectional data Ports, data rates up to 00 bps Supports RS, RS, MIDI Uses channel of audio for data transport per port Isolated I/O Copyright/Disclaimer All rights reserved. Permission to reprint or electronically reproduce any document or graphic in whole or in part for any reason is expressly prohibited, unless prior written consent is obtained from the Lawo AG. All trademarks and registered trademarks belong to their respective owners. It cannot be guaranteed that all product names, products, trademarks, requisitions, regulations, guidelines, specifications and norms are free from trade mark rights of third parties. All entries in this document have been thoroughly checked, however no guarantee for correctness can be given. Lawo AG cannot be held responsible for any misleading or incorrect information provided throughout this manual. Lawo AG reserves the right to change specifications at any time without notice Lawo AG, March 0
2 9/ Related Products Product Description Name DALLIS Frame RU RU, IO slots/hp, master card slots 90/0 DALLIS Frame RU RU, IO slots/hp, master card slots, phantom power slot 90/0 DALLIS Master ATM Port ATM, MMF. µm/00 nm, connector Duplex-SC, 0 channels I/O 9/0 DALLIS Master MADI Port MADI, MMF/SMF, 00 nm, connector Duplex-SC, channels I/O 9/X DALLIS Master MADI Ports MADI (redundant fibre), MMF/SMF, 00 nm, connectors Duplex-SC, 9/X channels I/O General T A = C. System sample frequency f s= khz or f s=9 khz unless otherwise noted. Parameter Conditions Min. Typ. Max. Unit Serial Ports Multi Format I/O # Standards RS RS MIDI Mode of operation System sample rates f s.//./9 khz Data rate. kbps Resolution requires transparent audio path ( MSBs) bits Cooling requirement Power dissipation V, all ports in RS mode. W Mechanical data Height RU Width HP Depth incl. locking devices mm Weight 9 g Power Supply T A = C. System sample frequency f s= khz or f s=9 khz unless otherwise noted. Parameter Conditions Min. Typ. Max. Unit Operating supply voltage DC. V Nominal supply current V, all ports in RS mode 0. A Nominal power consumption V, all ports in RS mode. W /9 Rev
3 9/ Multi Format Data Inputs T A = C. System sample frequency f s= khz or f s=9 khz unless otherwise noted. Parameter Conditions Min. Typ. Max. Unit Electrical specification Connector type RJ Data rate. kbit/s Delay RXD to Backplane out f s = khz. µs f s = 9 khz µs Receivers, RS mode Input voltage range RXD relative to ISOGND V Input threshold 0 (Space) relative to ISOGND.. V Input threshold (Mark) relative to ISOGND. 0. V Input resistance kω Maximum ground differential V GND V ISOGND 0 0 V Receivers, RS mode Input voltage range RXD+, RXD, relative to ISOGND V Differential threshold voltage min. noise margin of 0mV when no cable connected 00 0 mv Input Resistance Bus termination always on 00 Ω Maximum Ground Differential V GND V ISOGND 0 0 V Receivers, MIDI mode Input voltage range RXD+ relative to RXD 0. V Input current through optocoupler 0 ma Reverse voltage RXD+ relative to RXD V Multi Format Data Outputs T A = C. System sample frequency f s= khz or f s=9 khz unless otherwise noted. Parameter Conditions Min. Typ. Max. Unit Electrical specification Data rate. kbit/s Delay Backplane in to TXD f s = khz µs f s = 9 khz µs Transmitters, RS mode Output voltage swing TXD relative to ISOGND, load kω ± ±. V Driver Load kω Cable length data rate. kbit/s m Transmitters, RS mode Differential output voltage R Term = 00Ω. V Common mode output voltage TXD+, TXD, relative to ISOGND. V Short circuit output current prior to foldback current-limiting 0 +0 ma Cable length data rate. kbit/s 00 m Transmitters, MIDI mode Output voltage TXD+ relative to GND V Short circuit output current ma Cable length m /9 Rev
4 9/ Auxiliary Data T A = C. Master cards 9/0X, 9/X. Parameter Conditions Result Data In to Backplane Out Channel status data f s, no linear PCM audio, word length = Bit, Origin = Data, others default ) User data bit always 0 Validity bit always invalid Backplane In to Data Out Channel status data User data bit Validity bit ) Professional; Channel; CRC correct; all others 0 don t care don t care don t care Indicators Indicator Status Condition ACTIVE green flashing normal operation, no errors detected static green an internal error has occurred off no power or an internal error has occurred Jumpers Used to set data format for each port individually. RS RS MIDI Reserved (RS, future option) /9 Rev
5 9/ Further particulars/explanatory notes Introduction This DALLIS I/O-card was designed to provide a transparent bidirectional path for different types of serial data streams using PCM audio channels. Thereby, data rates up to 00 kbit/s are supported. The serial data is sampled, packed as audio and handled by the routing system like a regular audio source. Audio sent into the router will be marked as non PCM audio to avoid undesirable noise when accidentally routed to an analog output. To avoid ground loops with non-audio equipment the serial ports are isolated to the system audio ground. Warning Always carefully set the port jumpers to the desired port mode. Some of these modes generate voltages that may damage connected equipment, when electrical formats do not match! Also the 9/ may be damaged when applying stresses beyond the allowed range per port mode! Supported system sample rates Some text passages refer to sample rates as basic condition with respect to certain parameters. Please note that in this regard fs= khz also comprises fs=. khz and fs= 9 khz also comprises fs=. khz. The manufacturer's tests at fs= khz or fs= 9 khz are designed to represent all sample rates. Grounding All ports have an individual isolated signal ground with respect to the DALLIS audio ground potential. Maximum offset voltage between any applied signal ground and DALLIS audio ground is ±0V. When connecting a 9/ input to an isolated output, the signal ground must be tied to chassis ground at one end to avoid floating. Otherwise the maximum offset voltage might be violated, leading to incorrect function of the port. Connectors / Indicators SERIAL DATA 9/ /9 Rev
6 9/ Block diagram RJ el. Interface SAMPLE & PACK isolated UNPACK & RESTORE WCLK RJ el. Interface SAMPLE & PACK.... isolated UNPACK & RESTORE /9 Rev
7 9/ Port Modes The 9/ Serial Data card supports different electrical port formats RS ning RJ Comment RJ fe 9/ Transmitted data isolated TX GND 9/ Received data isolated GND isolated RX GND isolated GND connect to remote GND connect to remote GND RS wiring scheme to DTE fe RJ RJ Data Terminal Equipment e.g. Com Port of PC 9 DTE 9/ DTE 9/ Gnd Isognd = do not connect,,,, 9/ RS wiring scheme to DCE Data Communications Equipment DCE 9/ 9/ DCE 9/ e.g. Modem Gnd Isognd, 9,,, = do not connect RJ RJ /9 Rev
8 9/ RS ning RJ Comment RJ fe 9/ Transmitted data + 9/ Transmitted data - 9/ Received data + isolated GND 9/ Received data - isolated GND connect to remote GND connect to remote GND RS/Sony 9 wiring scheme Master to 9/ RJ RJ Sony 9 pin controlling device Master 9 Chassis Data + 9/ Data - 9/ TX GND Isognd RX GND Isognd Data - 9/ Data + 9/ Chassis 9/ = do not connect, RS/Sony 9 wiring scheme Slave to 9/ RJ RJ Sony 9 pin controlled device Slave 9 Chassis Data + 9/ Data - 9/ RX GND Isognd TX GND Isognd Data - 9/ Data + 9/ Chassis 9/, = do not connect /9 Rev
9 9/ MIDI ning RJ Comment RJ fe 9/ MIDI out + 9/ MIDI out - 9/ MIDI in + GND 9/ MIDI in - GND = Audio GND! = Audio GND! MIDI wiring scheme MIDI OUT to 9/ DIN RJ RJ MIDI out controlling device DIN SHLD MIDI + 9/ MIDI - 9/ Shield = do not connect,,,,, 9/ MIDI wiring scheme MIDI IN to 9/ RJ RJ MIDI in controlled device DIN SHLD SHLD GND MIDI + 9/ MIDI - 9/ SHLD GND = do not connect,,,, 9/ Note: A 9/ port in MIDI mode may also be used to interface with MIDI IN and MIDI OUT simultaneously. Please do not connect the cable shield at the receiving side. 9/9 Rev
DALLIS Product Information
Product Information To obtain the latest documentation and software downloads, please visit: www.lawo.com/downloads Copyright All rights reserved. Permission to reprint or electronically reproduce any
More informationManual Fiber Optic Interfaces
Manual Fiber Optic Interfaces Type 81210, 81211 61210, 61211 65210, 65211 41210 Release 1.4 Subject to error and alteration 31 06/2007 by Wiesemann & Theis GmbH Subject to error and alteration: Since it
More informationRS485 MODBUS Module 8I8O
Expansion Module 8 digital inputs, 8 digital outputs Version 2.2 12/01/2014 Manufactured for Thank you for choosing our product. This manual will help you with proper support and proper operation of the
More informationicex-cmtm General specs and Installation guide
icex-cmtm General specs and Installation guide 1. General view 2. Specifications 2.1. Common specs: Ethernet 1 x 10/100Base/T, RJ45 connector with traffic and link LED Serial Interface 1 x RS232/485 USB
More informationRS485 MODBUS Module 16I-M
Version 2.0 12/02/2013 Manufactured for Thank you for choosing our product. This manual will help you with proper support and proper operation of the device. The information contained in this manual have
More informationLVX Control Unit. Features:
Date 2013-02-28 Control Unit Features: Most parameters can be defined as required for your interfaces. You decide which information is output and how. Fast cycle times, just a few µs/beam. Maximum beam-count
More informationProduct type designation. General information. Supply voltage. Input current
Data sheet SIMATIC S7-300, CPU 312C COMPACT CPU WITH MPI, 10 DI/6 DO, 2 FAST COUNTERS (10 KHZ), INTEGRATED 24V DC POWER SUPPLY, 64 KBYTE WORKING MEMORY, FRONT CONNECTOR (1 X 40PIN) AND MICRO MEMORY CARD
More informationRS485 MODBUS Module 8I8RO
Expansion Module 8 digital inputs, 8 relay outputs Version 1.0 3.12.2014 Manufactured for Thank you for choosing our product. This manual will help you with proper support and proper operation of the device.
More informationSIMATIC. ET 200S distributed I/O Digital electronic module 4DO DC24V/0.5A ST (6ES7132-4BD02-0AA0) Preface. Properties 2. Diagnostics 3.
Preface 1 Properties 2 SIMATIC Diagnostics 3 ET 200S distributed I/O Digital electronic module 4DO DC24V/0.5A ST (6ES7132-4BD02- Manual 01/2008 A5E01254028-01 Safety Guidelines This manual contains notices
More informationACP 1703 Ax 1703 CM Fieldbus Interface Ring (3x FO, 1x el.)
ACP 1703 Ax 1703 CM-0821 Fieldbus Interface Ring (3x FO, 1x el.) Bus interface for an optical field bus or multi-point traffic as optical ring or optical star Features: 3 optical transmitter and receiver
More informationSER-4485-SI-M USER S MANUAL
SER-4485-SI-M USER S MANUAL 2017 May Edition Titan Electronics Inc. Web: www.titan.tw The computer programs provided with the hardware are supplied under a license. The software provided should be used
More informationIntegrity Instruments
Integrity Instruments P.O. Box 451 Order Phone 800-450-2001 Pine River Minnesota Fax Phone 218-587-3414 56474 USA Tech Phone 218-587-3120 http://www.integrityusa.com 485-25A High Speed RTS Enabled RS-232
More informationPB4350DAC1 - D/A Module User s Guide
PB4350DAC1 - D/A Module User s Guide Copyright The data in this document may not be altered or amended without special notification from ETAS GmbH. ETAS GmbH undertakes no further obligation in relation
More informationSerial Interface Modules TTL to RS232/RS485/RS422
USERS MANUAL Serial Interface Modules TTL to RS232/RS485/RS422 The modules converts serial TTL signals to RS232 or RS485/RS422. They are available in several different configuration such as directly mountable
More informationRS 232 to Fibre Optic Modems ELO E240, ELO E241, ELO E242. Operation manual
RS 232 to Fibre Optic Modems ELO E240, ELO E241, ELO E242 Operation manual 1.0 Introduction...3 1.1 Use of the modem...3 2.0 Operation principles...3 3.0 Installation...3 3.1 RS-232 Interface Connection...4
More informationIC-485S /IC-485SI. If anything is damaged or missing, contact your dealer.
User Manual IC-485S /IC-485SI Read this guide thoroughly and follow the installation and operation procedures carefully in order to prevent any damage to the units and/or any devices that connect to them.
More informationRS485 MODBUS Module 6RO
Version 2.0 12/02/2013 Manufactured for Thank you for choosing our product. This manual will help you with proper support and proper operation of the device. The information contained in this manual have
More informationRS 485 Mini Modbus 1AO
RS 485 Mini Modbus 1AO Version 1.0 14/08/2014 Manufactured for Thank you for choosing our product. This manual will help you with proper support and proper operation of the device. The information contained
More informationAccessories IC690ACC900
(IC690ACC900) datasheet Features Provides the IC69* programmable controllers with an interface to devices that use the RS- interface. Allows connection to programming computer without a Work Station Interface
More informationTRP-C06H User s Manual
TRP-C06H User s Manual 2-Port RS-232 to RS-422/485 Isolated Converter Printed Feb.2007 Rev 1.1 Trycom Technology Co., Ltd 1F, No.2-11, Sihu street, Hinge Township, Taipei, Taiwan ROC Tel: 886-2-86781191,
More informationRS485 MODBUS Module 8AO
Version 1.3 12/02/2013 Manufactured for Thank you for choosing our product. This manual will help you with proper support and proper operation of the device. The information contained in this manual have
More informationE&M (Ear and Mouth) Interface For OM200 SONET-OC3 Multiplexer
-& & (ar and outh) Interface For SONT-OC3 ultiplexer Chassis Chassis sizes of 2, 4, 6, and 16 slot. Optical data rate of 155bps Single or multimode fiber versions Point-to-point topology Add/drop topology
More informationSerial PROFIBUS Interface
Installation Manual Serial PROFIBUS Interface Version: EN-062016-2.3 Copyright 2016 Softing Industrial Automation GmbH Disclaimer of liability The information contained in these instructions corresponds
More informationProduct type designation. General information. Supply voltage
Data sheet SIMATIC S7-300, CPU 313C-2DP COMPACT CPU WITH MPI, 16 DI/16 DO, 3 FAST COUNTERS (30 KHZ), INTEGRATED DP INTERFACE, INTEGRATED 24V DC POWER SUPPLY, 128 KBYTE WORKING MEMORY, FRONT CONNECTOR (1
More informationSIMATIC. ET 200S distributed I/O Digital electronic module 4DO DC24V/0.5 A ST (6ES7132-4BD01-0AA0) Preface. Properties 1. Diagnostics 2.
SIMATIC ET 200S distributed I/O Digital electronic module 4DO DC24V/0.5 A ST (6ES7132-4BD01- SIMATIC Preface Properties 1 Diagnostics 2 ET 200S distributed I/O Digital electronic module 4DO DC24V/0.5 A
More informationThis data sheet is only valid in association with the IL SYS INST UM E user manual.
Inline analog input terminal, 4 inputs for connecting voltage signals Data sheet 8081_en_01_C01 PHOENIX CONTACT 2015-04-14 1 Description The terminal is designed for use within an Inline station. It is
More informationIssue 03/2013. The Electronic Load
Issue 03/2013 ZS Electronic Loads, PL Series Interface overview RS-232 USB / GPIB LAN System bus Analog X Analog isolated / X Standard ption / not available PL506 PL1006 Voltage Current Resistance 3) Model
More informationSCB-C08 USB to RS232/422/485 Converter
SCB-C08 USB to RS232/422/485 Converter USB Interface RS-232 signal RS-422 signal: RS-485 signal: Cable Type Transmission distance Signal LED Direct power from USB port Power consumption: Compliant with
More informationGeneral Specifications. P2-SCM Serial Communications
General Specifications Module Type Intelligent Modules per Base I/O Points Used Field Wiring Connector Operating Temperature Storage Temperature Humidity Environmental Air Vibration Shock Field to Logic
More informationMED102A. Industrial Serial to Single-mode Fiber Converter
MED102A - 0708 pg. 1 / 5 MED102A Industrial Serial to Single-mode Fiber Converter Data Rates up to 115.2 kbps 9 Mile (15 km) Range 10 to 48 VDC Input Voltage Wide Operating Temperature 2000V Isolation
More informationRC702-FX Ethernet over SDH User Manual
RC702-FX Ethernet over SDH User Manual Raisecom Technology Co., Ltd 1. Caution Please carefully read the following precautions before installing and deploying RC702-FX equipment, and operate strictly according
More informationMEV Limited USB232/485 INSTRUCTION MANUAL
MEV Limited USB232/485 INSTRUCTION MANUAL USB TO RS232 / RS485 SERIAL COMMUNICATIONS INTERFACE WITH ISOLATION OPTION Issue 5 LIST OF CONTENTS 1 INTRODUCTION 1 1.1 The Products Described in this Manual
More informationIBS IL 24 BK RB-T-2MBD
IBS IL 24 BK RB-T-2MBD INTERBUS Inline Terminal for Connecting a Remote Bus Branch Data Sheet 6766A 01/2003 $! $ * This data sheet is only valid in association with the "Configuring and Installing the
More informationGeneral information. Supply voltage
Data sheet SIMATIC S7-300, CPU 313C-2DP COMPACT CPU WITH MPI, 16 DI/16 DO, 3 FAST COUNTERS (30 KHZ), INTEGRATED DP INTERFACE, INTEGRATED 24V DC POWER SUPPLY, 128 KBYTE WORKING MEMORY, FRONT CONNECTOR (1
More informationMoxa TCC-100 Series User s Guide
Moxa TCC-100 Series User s Guide Eighth Edition, February 2009 www.moxa.com/product 2009 Moxa Inc. All rights reserved. Reproduction without permission is prohibited. Moxa TCC-100 Series User s Guide The
More informationProgrammable CMOS LVDS Transmitter/Receiver
SPECIFICATION 1. FEATURES Technology TSMC 0.13um CMOS 3.3 V analog power supply 1.2 V digital power supply 1.2V CMOS input and output logic signals 8-step (3-bit) adjustable transmitter output current
More informationDirectOut Technologies
DirectOut Technologies D.O.TEC ANDIAMO.MC Info Remote Protocols Version 1.0 Copyright Note DirectOut Technologies Copyright All rights reserved. Permission to reprint or electronically reproduce any document
More informationTRP-C08. USB to RS232/422/485 Isolated Converter. User s Manual. Printed Sep.2014 Rev 1.4
TRP-C08 USB to RS232/422/485 Isolated Converter User s Manual Printed Sep.2014 Rev 1.4 Trycom Technology Co.,Ltd No.35, Zhongxing Rd., Guishan Township, Taoyuan County 333, Taiwan. Tel : 886-3-350-3351
More informationAmarjeet Singh. January 30, 2012
Amarjeet Singh January 30, 2012 Website updated - https://sites.google.com/a/iiitd.ac.in/emsys2012/ Lecture slides, audio from last class Assignment-2 How many of you have already finished it? Final deadline
More informationGFK-2415A March Type of sensor connection
VersaMax IP Expansion Module has four analog differential inputs that can be configured as current or voltage inputs. It connects to a local bus that is interfaced to a Profibus-DP / PROFINET network by
More informationThe AMG5715A1B9 is designed to be powered using an AMG2001 standalone power supply.
AMG5715A1B9 Instruction Manual Single Channel Video Transmit Unit with one Bi-directional Data Channel, two Uni-directional Alarms and one Bidirectional Audio Channel for a Singlemode Fibre Link The AMG5715A1B9
More informationGE Fanuc IC694ALG221. Rx3i PacSystem
GE Fanuc IC694ALG221 http://www.pdfsupply.com/automation/ge-fanuc/rx3i-pacsystem/ic694alg221 Rx3i PacSystem Input module, analog 4 point current. IC694A IC694AL IC694ALG 919-535-3180 sales@pdfsupply.com
More informationInterface Converter. Installation Manual IC485S IC485SGB IC485SEU. RS-232 to RS-485/422 Serial Interface Converter
Interface Converter RS-232 to RS-485/422 Serial Interface Converter Installation Manual GB EU 1 Overview Changing line signals is no longer a problem. StarTech.com s / GB / EU converts RS-232 serial interfaces
More informationData sheet CPU 115 (115-6BL02)
Data sheet CPU 115 (115-6BL02) Technical data Order no. 115-6BL02 Type CPU 115 General information Note - Features 16 (20) inputs 16 (12) outputs from which are 2 PWM 50 khz outputs 16 kb work memory,
More informationHEC. General Operating, Maintenance and Installation Manual
HEC General Operating, Maintenance and Installation Manual D-91056 Erlangen Phone: +49 9131 7677 47 Fax: +49 9131 7677 78 Internet : http://www.ipcomm.de Email: info@ipcomm.de Edition November 2005 Version
More informationCommercial-grade Interface Converter User Manual
Suzhou Huarui Thermal Control Co.,Ltd Commercial-grade Interface Converter User Manual Read this manual carefully before installation and use! The document is the exclusive property of SUZHOU HUARUI Thermal
More informationT1K MODBUS Base Controller Specifications
Base Controller 1 2 In This Chapter.... Base Controller Setting the DIP Switches Setting the Rotary Address Switches Port Pin out and Wiring RJ12 Serial Port Pin out and Wiring 2 2 Base Controller General
More informationSDM-8AO. Expansion Module 8 analog outputs. Manufactured for
Version 1.0 16.05.2014 Manufactured for Thank you for choosing our product. This manual will help you with proper support and proper operation of the device. The information contained in this manual have
More informationABB Drives. User s Manual Modbus Adapter Module FMBA-01
ABB Drives User s Manual Modbus Adapter Module FMBA-01 Modbus Adapter Module FMBA-01 User s Manual 3AFE68586704 REV A EN EFFECTIVE: 27.06.2005 2005 ABB Oy. All Rights Reserved. 5 Safety instructions
More informationPrisma II Platform. Optoelectronics
Optoelectronics Prisma II Platform Description In optical transmission systems, the network platform forms the foundation of the product family. The Prisma II platform provides network operators with the
More informationGeneral information. Engineering with. Supply voltage. Load voltage L+ Input current. Power losses. Memory. Work memory.
Product data sheet SIMATIC S7-300, CPU 314C-2DP COMPACT CPU WITH MPI, 24 DI/16 DO, 4AI, 2AO, 1 PT100, 4 FAST COUNTERS (60 KHZ), INTEGRATED DP INTERFACE, INTEGRATED 24V DC POWER SUPPLY, 64 KBYTE WORKING
More informationManual Industry Interfaces
Manual Industry Interfaces W&T Release. Type 0, 0 0, 00 0, 0 0, 0 Industry Interfaces 0/0 by Wiesemann & Theis GmbH Subject to errors and changes: Since we can make mistakes, none of our statements should
More informationCS485. User s Manual. Version ZYPEX, Inc.
CS485 User s Manual Version 2.0 2003 ZYPEX, Inc. Table of Contents Product Description 1 CS485 Configuration & Setup 2 4-wire Operation 2 2-wire Operation 2 Dual Port Operation 2 Carrier Detect 2 Transmitter
More informationFCC Information. RoHS This product is RoHS compliant. SJ/T The following contains information that relates to China.
FCC Information This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection
More informationVersaMax IP I/O Module
Module accepts four digital input signals and provides four digital outputs. It connects to a local bus that is interfaced to a Profibus-DP / PROFINET network by a Profibus Interface Unit (IC677PBI001)
More informationAccessories / 7XV5662
Accessories / XV Communication Converter XV-0AA00/GG for X. / RS / G.0. *) Fig. / Communication converter for X./ RS and G.0. The communication converter CC-XG for coupling to a communication network is
More informationABB Drives. User s Manual. Modbus Adapter Module RMBA-01
ABB Drives User s Manual Modbus Adapter Module RMBA-01 Modbus Adapter Module RMBA-01 User s Manual 3AFE 64498851 REV A EN EFFECTIVE: 1.3.2002 2002 ABB Oy. All Rights Reserved. Safety instructions Overview
More informationwarning indication issued about 2 weeks before the battery charge becomes critical Real-time clock - with battery back-up Yes
System Freelance 800F AC 700F Module Description Data Sheet Central Processing Unit PM 783F Detailed data of the CPU (PM 783F) CPU Processor Program memory (Battery backed up) Internal memory Typical cycle
More informationSDM-8I8O. Expansion Module 8 digital inputs, 8 digital outputs. Manufactured for
Version 1.2 20.01.2014 Manufactured for Thank you for choosing our product. This manual will help you with proper support and proper operation of the device. The information contained in this manual have
More informationIB ST 24 AO 4/EF. INTERBUS-ST analog output module, 4 outputs, 0-10 V, ±10 V, 0-20 ma, 4-20 ma. Data sheet. 1 Description
INTERBUS-ST analog output module, 4 outputs, 0-10 V, ±10 V, 0-20 ma, 4-20 ma Data sheet 105597_en_01 PHOENIX CONTACT 2014-10-24 1 Description The module is designed for use within an ST station. It is
More information3710 ACM 3750 PDC 3800 RTU. ISOCOM Communications Card Retrofit Instructions
3710 ACM 3750 PDC 3800 RTU ISOCOM Communications Card Retrofit Instructions Danger During normal operation of this device, hazardous voltages are present which can cause severe injury or death. These
More informationRexroth Inline terminal with one analog output
Electric Drives Hydraulics Linear Motion and Assembly Technologies Pneumatics Service Rexroth Inline terminal with one analog output R911170602 Edition 01 R-IB IL AO 1/SF-PAC 1 analog output 2-wire technology
More informationW&T. Universal Fiber Optic Interface Converter W&T. Manual. Universal FO Interface Converter. Model Release 1.0. Subject to error and alteration
Manual Universal FO Interface Converter Model 81215 Release 1.0 Subject to error and alteration 13 10/2012 by Wiesemann & Theis GmbH Subject to error and alteration: Since it is possible that we make mistakes,
More informationMoxa TCC-100 Series Hardware Installation Guide
Moxa TCC-100 Series Hardware Installation Guide Twelfth Edition, January 2015 www.moxa.com/product 2015 Moxa Inc. All rights reserved. P/N: 1802001000319 Moxa TCC-100 Series Hardware Installation Guide
More informationRTU560 Connections and Settings DIN Rail RTU 560CIG10
Connections and Settings DIN Rail RTU 560CIG10 Application, characteristics and technical data have to be taken from the hardware data sheet: 560CIG10 1KGT 150 719 Operation The 560CIG10 is a DIN rail
More informationINSTALLATION MANUAL. LC 200 Electronic Overload Guard. Software versione PW0501 R 0.3
INSTALLATION MANUAL LC 200 Electronic Overload Guard Software versione PW0501 R 0.3 CONTENTS MAIN FEATURES LC 200 TECHNICAL FEATURES Page 2 SYMBOLS Page 3 WARNINGS Page 3 IDENTIFICATION DATA PLATE Page
More informationThe Wireless Connectivity Expert
The Wireless Connectivity Expert 48511 Warm Springs Blvd., Suite 206, Fremont CA 94539 Tel: (510) 490-8024 Fax: (510) 623-7268 Website: http://www.actisys.com/ E-mail: irda-info@actisys.com ACT-IR100SD
More informationICF-1150 Series Quick Installation Guide
ICF-1150 Series Quick Installation Guide Second Edition, March 2012 2012 Moxa Inc. All rights reserved. P/N: 1802011500011 Overview Introduction The ICF-1150 series fiber converters are equipped with a
More informationAdvant OCS. The Compact and Cost Effective Advant Controller. Advant Controller 210. Open Control System
Advant OCS Open Control System Advant Controller 210 The Compact and Cost Effective Advant Controller Advant Controller 210 is a small, cost-effective system belonging to the Advant Controller family.
More information515RTAAIC Interface Converter
515RTAAIC Interface Converter Product User Manual Version 1.2 Real Time Automation, Inc. 1 1-800-249-1612 Trademarks CompactLogix, ControlLogix, & PLC-5 are registered trademarks of Rockwell Automation,
More information2562 QUICK START GUIDE
2562 QUICK START GUIDE CTI P/Ns: 2562 Quick Start Guide: 062-00348-010 2562 Installation and Operation Guide: 062-00332-011 Summary: The 2562 is designed to translate a digital word from the programmable
More informationChannel Switch CS. General Operating, Maintenance and Installation Manual
Channel Switch CS General Operating, Maintenance and Installation Manual D-91056 Erlangen Phone: +49 9131 7677 47 Fax: +49 9131 7677 74 Internet: http://www.ipcomm.de Email: info@ipcomm.de Edition September
More informationSupply voltage. Input current. Encoder supply. Memory SIMATIC S7-200, CPU 221 COMPACT UNIT, DC POWER SUPPLY 6 DI DC/4 DO DC, 4 KB CODE/2 KB DATA,
Data sheet SIMATIC S7-200, CPU 221 COMPACT UNIT, DC POWER SUPPLY 6 DI DC/4 DO DC, 4 KB CODE/2 KB DATA, Supply voltage Rated value (DC) 24 V DC Load voltage L+ Rated value (DC) permissible range, lower
More informationPCAN-MicroMod Analog 1 Application-specific PCAN-MicroMod Motherboard. User Manual. Document version ( )
PCAN-MicroMod Analog 1 Application-specific PCAN-MicroMod Motherboard User Manual Document version 1.11.3 (2017-09-12) Relevant products Product Name Model Part number PCAN-MicroMod Analog 1 Including
More informationBB-303 Manual Baseboard for TMCM-303
BB-303 Manual Baseboard for TMCM-303 Trinamic Motion Control GmbH & Co. KG Sternstraße 67 D 20357 Hamburg, Germany http://www.trinamic.com BB-303 Manual (V1.04 / Jul 9th, 2007) 2 Contents 1 Features...
More information-C5RS-LC RS232 EXTENDER
XTENDEX Series ST-C5RS-LC RS232 EXTENDER Installation and Operation Manual ST-C5RS-LC RS232 Extender Man249 Rev. 10/30/17 TRADEMARK XTENDEX is a registered trademark of Network Technologies Inc in the
More informationHP 48 I/O Technical Interfacing Guide
HP 48 I/O Technical Interfacing Guide HP 48 I/0 Technical Interfacing Guide CONTENTS INTRODUCTION... 3 WIRED SERIAL I/O HARDWARE... 3 CABLE WIRING... 3 SERIAL FORMAT... 5 Example: an 'H' (48 hex)... 5
More informationSerial to RS422/485 Converter SER 485 PRO( SI) User Manual
Serial to RS422/485 Converter SER 485 PRO( SI) User Manual Edition: April 2008 Tel: +49 40 528 401 0 Fax: +49 40 528 401 99 Web: www.visionsystems.de Support: service@visionsystems.de The software described
More informationNetwork audio encoder / decoder with I/O for professional and broadcast applications
Exstreamer 500 PRODUCT MANUAL Network audio encoder / decoder with I/O for professional and broadcast applications Document version 01.00 Release date 28. June 2012 Hardware Rev. 1.x 2010 Barix AG, all
More informationUSB-COM Plus ISO (USB-COMi SI-M)
VS Vision Systems GmbH / Part Number 603 Features 1 x RS232/422/485 port USB 2.0 Full Speed interface 2.5kV isolation per serial port USB and serial ports ESD protected Robust metal case Jumperless, DIP
More informationSDM-6RO. Expansion Module 6 relay outputs. Manufactured for
Version 1.0 5.02.2014 Manufactured for Thank you for choosing our product. This manual will help you with proper support and proper operation of the device. The information contained in this manual have
More informationVersaPoint I/O Module
Output 24VDC Positive Logic 0.5A 14 Points Module is used to output 24VDC digital signals. Module Specifications Housing dimensions (width x height x depth) Connection style Operating temperature 48.8mm
More informationTCF-142-RM Series Hardware Installation Guide
TCF-142-RM Series Hardware Installation Guide Third Edition, March 2015 2015 Moxa Inc. All rights reserved. P/N: 1802001420622 *1802001420622* Overview Introduction The TCF-142-RM series fiber converters
More informationAXL E IOL AO1 U M12 R
Axioline E IO-Link/analog converter for connecting an analog actuator, 0 V... 10 V, rectangular version Data sheet 8588_en_03 PHOENIX CONTACT 2014-09-22 1 Description The IO-Link/analog converter is an
More informationPCAN-MicroMod Analog 2 Application-specific PCAN-MicroMod Motherboard. User Manual. Document version ( )
PCAN-MicroMod Analog 2 Application-specific PCAN-MicroMod Motherboard User Manual Document version 1.12.2 (2017-09-12) Relevant products Product Name Model Part number PCAN-MicroMod Analog 2 Including
More informationVL BPC MINI. A configurable industrial computer platform Intel Atom Z510PT CMAT IPC Module Option [I28] AUTOMATION Data Sheet 2930_en_A.
A configurable industrial computer platform Intel Atom Z0PT CMAT IPC Module Option [I8] AUTOMATION Data Sheet 90_en_A Description PHOENIX CONTACT 0-0-0 Features The VL BPC MINI is an embedded box PC and
More informationI-7520: RS-232 to RS-485. Input: RS-232 protocol Output:RS-485/RS-422 Speed: Self Tuner 'inside, auto switching baud rate, 300~ BPS
I-7520 RS-232 to RS-485 Converter I-7510 RS-485 Repeater RS-232 RS-485 I-7000 SERIES Common Specifications Isolation voltage: 3000VDC Speed: 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115000 Dual watchdog
More informationUSER MANUAL. G.shdsl+ modem with G.703 interface TAHOE 671 FREEDOM OF COMMUNICATION
USER MANUAL G.shdsl+ modem with G.703 interface TAHOE 671 FREEDOM OF COMMUNICATION TABLE OF CONTENTS 1. Introduction... 1 2. Interfaces... 2 3. Modem configuration using built-in keyboard and LCD.4 4.
More informationFLM DI 8 M12. Function. Fieldline Modular Device With Eight Digital Inputs. Data Sheet
Fieldline Modular Device With Eight Digital Inputs Data Sheet 697000 02/2004 This data sheet is only valid in association with the FLS FLM SYS INST UM E user manual or the user manual for your bus system
More informationTS2043 Preliminary CMOS IC
UNISONIC TECHNOLOGIES CO., LTD TS2043 Preliminary CMOS IC TOUCH PANEL CONTROLLER DESCRIPTION The UTC TS2043 is a highly integrated 12-bit SAR analog-to-digital (A/D) converter designed for touch panel
More informationData sheet VIPA CPU 115DP (115-6BL22)
Data sheet VIPA CPU 115DP (115-6BL22) Technical data Order no. Type 115-6BL22 VIPA CPU 115DP General information Note - Features Work memory [KB]: 16 Load memory [KB]: 24 Onboard 16x DI / 12x DO / 4x DIO
More informationET 200S distributed I/O system 4DO DC24V/2A ST digital electronic module (6ES7132-4BD32-0AA0)
4DO DC24V/2A ST digital electronic module (6ES7132-4BD32- SIMATIC Preface 1 Properties 2 Diagnostics 3 ET 200S distributed I/O system 4DO DC24V/2A ST digital electronic module (6ES7132-4BD32- Manual 10/2015
More informationCraft Port Tiny RS-232 Transceiver for Portable Applications ADM101E. Data Sheet FUNCTIONAL BLOCK DIAGRAM
Data Sheet FEATURES 460 kbit/s Transmission Rate Single 5 V Power Supply Compatible with RS-232 Input/Output Levels 0.1 μf Charge Pump Capacitors One Driver and One Receiver On-Board DC-DC Converter ±4.2
More informationGYM Bilgi Teknolojileri
www.fibridge-tr.com bilgi@gym-tech.net GYM Bilgi Teknolojileri E1 and V.35 Modem User Manual (Version 1.0) Beijing Fibridge Co., Ltd Table of Content 1. Overview... 1 2. Features... 1 3. Specification...
More informationData sheet CC 03, Commander Compact (603-1CC21)
Data sheet CC 03, Commander Compact (603-1CC21) Technical data Order. Type 603-1CC21 CC 03, Commander Compact General information Note - Features Display: 2 x 20 characters Interface: MP²I User memory:
More informationPCAN-MicroMod Mix 2 Application-specific PCAN-MicroMod Motherboard. User Manual. Document version ( )
PCAN-MicroMod Mix 2 Application-specific PCAN-MicroMod Motherboard User Manual Document version 1.11.3 (2017-09-12) Relevant products Product Name Model Part number PCAN-MicroMod Mix 2 Including casing
More informationW&T Manual Interface modules W&T
Manual Subject to error and alteration Model 18801, 18811 18802, 18812 18803, 18813, 18833 18601, 18611 18602, 18612 18613, 18633 18401, 18411 18402, 18412 Release 1.7 43 09/2013 by Wiesemann und Theis
More informationSLD-mCS/sCS-series Miniature High Power Broadband Light Source Modules
SLD-mCS/sCS-series Miniature High Power Broadband Light Source Modules Technical Product Specification Document ID: SL.RD.01.001.170215 March 2017 Revision: 002 ATTENTION ELECTROSTATIC SENSITIVE DEVICES
More informationRER 123 Bus Connection Module. Technical Description
Bus Connection 1MRS751143-MUM Issued: 06.11.1998 Version: E/08.07.2005 Bus Connection 1. About this manual...4 1.1. Copyrights...4 1.2. Trademarks...4 1.3. Guarantee...4 2. Safety information...5 3. General...6
More informationILBPB24DO32. Inline Block IO Module for PROFIBUS With 32 Digital Outputs. AUTOMATIONWORX Data Sheet 6889_en_04. Description
Inline Block IO Module for PROFIBUS With 32 Digital Outputs AUTOMATIONWORX Data Sheet 6889_en_04 Description PHOENIX CONTACT - 03/2007 & & ' ) The ILB PB 24 DO32 module is designed for use within a PROFIBUS
More information