NX21 USER MANUAL. Telemetry Unit. Version 1.5
|
|
- Shon Phillips
- 6 years ago
- Views:
Transcription
1 USER MANUAL Version 1.5 Nortech Management Ltd, United Kingdom NOV Doc Ref D_000344
2 Publication Notice Copyright Nortech Management Limited (NML). All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form or by any means, including photocopying, electronic, mechanical, recording or otherwise, without the prior written permission of the copyright holder. NML provide this document as is, without warranty of any kind either expressed or implied including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. NML may make changes or improvements in the software, equipment, or specifications described in this document at any time and without notice. These changes may be incorporated in new releases of this document. This publication could contain technical inaccuracies or typographical errors. NML shall not be liable for any damages (including, but not limited to, consequential, indirect or incidental, special damages or loss of profits or data) even if NML have been informed of their potential occurrence, arising out of or in connection with this document or its use. English Edition IBM PC is a trademark of International Business Machines Inc. Windows is a trademark of Microsoft Corporation. All other trademark names used in this manual are hereby acknowledged. Nortech Management Ltd, United Kingdom Page 2 of 17
3 Contents 1. NX21 RTU Description 4 Operation 4 Central Host User Interface 4 Communications 4 2. Product Hardware and Lifetime support 5 3. Photograph 6 4. Wiring Connections 7 5. Commissioning / Field Support Kit 8 6. RTU Specification 9 Clock 9 Inputs / Outputs 9 RTU Events 9 Binary Inputs 9 Analogue Inputs 9 Datalogging of Analogue Inputs 10 Log Sizes 10 Input monitoring during host calls 10 Temperature 10 Signal Strength 10 Calls between RTU and Host 10 Reconfiguration of the RTU settings Typical RTU Operation 11 Cold Start. 11 LEDs 11 Reason for the RTU to call the Host 11 Calls to the Host 11 Call Retry Algorithm 11 Incoming Calls Communication Methods 12 Local Only 12 GSM / GPRS Modem 12 Selecting GSM or GPRS connection type Wiring Diagram Mounting Drawing Specification 15 Battery Life 15 EMC Tests Options and Accessories 16 Transducer Power Supply Daughter Board 16 NXD8 1 in, 2 out daughter board 17 Nortech Management Ltd, United Kingdom Page 3 of 17
4 1. NX21 RTU Description Operation The NX21 RTU (Remote Terminal Unit) is suitable for alarm and condition monitoring applications as well as datalogging applications. The NX21 monitors equipment status via digital inputs and analogue inputs. The NX21 can be supplied with a long-life lithium battery pack allowing monitoring at sites where an auxiliary supply is not available. Operational life of up to 10 years is possible between battery replacement depending on the configuration of the RTU sampling and reporting settings. Typical applications include: General plant alarm panel monitoring Tank Level Monitoring Circuit Breaker operation monitoring Telecommunication base station monitoring Central Host User Interface For UK customers the NX21 can be remotely monitored from a set of Nortech webpages called Web ihost. These are accessed via a unique username and password. Once inside the Alarm displays, events histories and NX21 configuration can be viewed and managed. For larger customers a dedicated ihost System can be installed at their own premises. The functionality of the User Interface is described in a separate document. Communications As standard the NX21 will be supplied with a quad band GSM/GPRS modem and antenna. This provides low cost wide area wireless communications between the NX21 site and the Central Host. For datalogging applications where no remote gathering of data is required then the modem can be omitted. Nortech Management Ltd, United Kingdom Page 4 of 17
5 2. Product Hardware and Lifetime support The NX21 product is available with either a high density set of connectors (NX61 pcb option) or a set of screw terminals (NX21 pcb option). pcb designation NX21 Photograph Comment 2 part screw terminals. Quad band modem. External SIM card holder. NX61 High density connectors. Quad band modem. External SIM card holder. Depending on the part number selected the NX21 can be supplied in a number of different packages including enclosures, batteries, brackets, cabling etc. All pcb footprints mount inside the 130x130x75 mm enclosure. Note modems vary depending on the age of the unit. Nortech Management Ltd, United Kingdom Page 5 of 17
6 3. Photograph NX21 pcb variant No. Description 1 Test Button and 2 LEDs for TX/RX 2 16-bit Microprocessor 3 COM1 RTU configuration port 4 Analogue Inputs 5 Digital inputs Digital inputs GSM/GPRS modem 8 Antenna Connection 9 SIM Card Holder 10 Battery / DC power connection 11 Temp Transducer NX61 pcb variant Nortech Management Ltd, United Kingdom Page 6 of 17
7 4. Wiring Connections The RTU requires a power supply from either a Long-Life lithium battery pack (in which case there is no need for any auxiliary power supply) or from a constant DC source fed via a Nortech DC Supply Board. Digital Inputs are monitored using internal pull-ups, there is no opto isolation between the RTU and the equipment being monitored. Where opto-isolation is required for a particular application plug in daughter board are available. Analogue inputs are monitored via 0-25mA inputs and are therefore suitable for use with externally powered 4-20mA sensors. There is an 18V switched DC supply available as an optional extra which can be used to supply power to external 4-20mA sensors. A wiring diagram is included in this manual. Nortech Management Ltd, United Kingdom Page 7 of 17
8 5. Commissioning / Field Support Kit Connect the NX21 to the PC using the NXA-0100 serial cable plugged into the RJ45 socket as shown in the earlier photograph. Run the NX-FSK Field Support Kit software on the laptop. The Field Support Kit PC software allows users to interrogate the current status and settings of the NX21 as well as look at archived logs. NXA-0100 programming lead The Field Support Kit is described in a separate document. Nortech Management Ltd, United Kingdom Page 8 of 17
9 6. RTU Specification Clock The RTU has an internal Real Time Clock (RTC). The clock is synchronised with the Host during every communication. Date/time stamping in Event and System logs is to 0.1 second granularity. The RTC has a drift of 1/1,000,000. Inputs / Outputs There are 12 digital inputs. These are configured to operate as Binary Inputs. There are 2 analogue inputs with 8-bit resolution each with 4 threshold settings. RTU Events Power up from cold (Cold Start) will usually be configured to initiate a call to the host. Binary Inputs The RTU reports the current status of all binary inputs to the host during every call. The RTU is able to detect binary state changes of 250ms duration or longer. Once an event has been detected then the RTU can be configured to fast scan the binary inputs for up to 4 minutes during which time inputs changes of 10ms duration will be detected. Binary inputs are configured to detect OPEN or CLOSE or BOTH changes of state. Binary inputs can be configured as latched with an associated latched timer, in this mode when a change of state occurs the RTU will ignore further changes of state on that input until the timer has expired. When a monitored change of state occurs a date/time stamped binary input change log entry is made. Binary input change of state can be configured to initiate an immediate call to the host. Analogue Inputs The RTU reports the last reading of the 8-bit analogue value of each input to the host during every call. Each analogue input has 4 threshold levels associated with it. If during a reading a threshold level has been crossed since the last reading then the RTU adds a date/time stamped entry in the analogue threshold log. The hysteresis for threshold crossings is 5. The 8-bit value of corresponds to a 0-25mA level on the input. e.g. 200 = 19.61mA. Analogue inputs crossing threshold can be configured to be logged and initiate an immediate call to the host. It is possible to provide power to external 4-20mA type sensors via a switched output power line on the board. A Nortech DC-DC step up board is needed for this option. The powering of the external sensors can be synchronised with the reading of the analogue input levels. The 2 analogue inputs are read at configurable intervals in the range 1 to 4000 minutes. When the time for the analogue reading to occur is reached the analogues and the external switched power line are energised for a stabilise time prior to taking a readings. Nortech Management Ltd, United Kingdom Page 9 of 17
10 Datalogging of Analogue Inputs Analogue inputs can be configured for datalogging their value each time they are read. If enabled then the RTU stores the current level and the date/time the reading was taken. During the next contact with the Host these datalogs will be transferred. Log Sizes Logs are stored in non-volatile memory. With the standard memory the RTU can store: 100 Binary Logs 1500 Analogue threshold crossings and datalogs 100 RTU and communications events When a log fills then the 100 th (1500 th ) entry is stored as a buffer overrun and then the log loops back and overwrites the oldest data. Input monitoring during host calls Inputs continue to be monitored during calls to the Host. If a binary or analogue input event takes place during a call the Log entry is still be made. Temperature The RTU takes a temperature reading using it s on board sensor at the same time as the analogue inputs have been configured to be read. The last temperature reading taken is reported to the Host during every contact. Signal Strength The RTU monitors the GSM/GPRS signal strength during each call. The last measured signal strength is reported to the Host during every call. Calls between RTU and Host When the RTU calls the Host the Host software answers the call and initiates a transfer of data in both directions using a secure protocol. During contact with the Host the RTU acts as a slave serving information to requests by the Host acting as master. Information from the RTU is stored in the Hosts database where users may view it. Reconfiguration of the RTU settings The operational behaviour of the RTU including which inputs are enabled, how data is stored and reported to the Host and how often contact with the host is required are all configurable centrally from the Host without the need for a site visit. When a Host User makes changes to these settings at the Host the new settings will be loaded into the RTU during the next contact between the Host and the RTU. Nortech Management Ltd, United Kingdom Page 10 of 17
11 7. Typical RTU Operation Assumes a GSM modem is fitted. Cold Start. The RTU should be configured to monitor processor power up after periods without mains and battery back-up power, this is known as a Cold Start. The RTU will then initiate a call to the host when a Cold Start event takes place. LEDs The Processor LEDs are used to indicate current operation state of the NX21 along with communication state. Mode Green LED Red LED Normal Operation, OFF OFF Using modem, dialling, communicating etc... Follows TX End of a Successful call... 5s ON then OFF OFF Follows RX End of a failed call... OFF 5 s ON then flashing (see below) during retry algorithm. During retry algorithm... OFF Flashing 200ms ON, 2s OFF End of Retry Algorithm... same as normal operation. Flashing 200ms ON, 2s OFF OFF Reason for the RTU to call the Host When the user presses the test button the RTU initiates a call to the Host. When the Next Routine Call date/time is reached/exceeded the RTU initiates a call to the Host. When an event takes place that is configured to initiate a call to the host. Calls to the Host When the RTU initiates a call to the Host it waits the call in delay timer period before dialling. The RTU keeps track of, and reports to the Host, a set of call success statistics. Call Retry Algorithm If a call to the Host fails then the RTU retries to a total of 10 times over a period of approximately 20 minutes. The interval between retries varies between RTUs so that different RTUs don t have the same retry interval algorithm. If all 10 attempts fail then the RTU will start retrying again (another 10 attempts) 24 hours later. During this period if any other events occur requiring the RTU to call the Host it should do so in the normal manner. Incoming Calls When using the lithium battery pack the RTU switches off the modem except when required to call the Host. Therefore the Host is unable to initiate contact with the RTU. When an external DC power source is used the RTU keeps the modem powered up between calls and the Host can call ( poll ) the RTU which will answer the call. Nortech Management Ltd, United Kingdom Page 11 of 17
12 8. Communication Methods Local Only Plug in the Field Support Kit lead into COM1 and download onto PC the contents of the RTUs logs. GSM / GPRS Modem A GSM/GPRS modem can be directly fitted to COM 0 at Nortech. Serial communication and power is provided by this connection. The RTU communicates using the NX protocol over GSM and GPRS networks. Various settings need to be set in order for the RTU to use the GSM / GPRS modem, these will usually be configured by Nortech as part of the pre-delivery checks. A SIM card is needed to gain GSM / GPRS Network access. The SIM card needs to be CSD Data enabled and/or GPRS enabled. Selecting GSM or GPRS connection type The NX21 supports both Circuit Switched Data and GPRS connections types. The choice of which type to use is software switchable either as a factory configured option by Nortech or by the user using the Field Support Kit. Each option in turn has it s own settings which are used to connect to the Host. GPRS needs Host IP addresses setting, CSD needs Host phone numbers setting etc. The software switch is available from firmware v10 onwards. For help in deciding on which option to use please contact Nortech. Nortech Management Ltd, United Kingdom Page 12 of 17
13 9. Wiring Diagram Digital Inputs should be volt-free dry contacts. Analogue Inputs should be 4-20mA. Only use a lithium battery pack or DC power board supplied by Nortech. NX21 pcb variant NX61 pcb variant Nortech Management Ltd, United Kingdom Page 13 of 17
14 10. Mounting Drawing The NX21 can be supplied in a number of different enclosure sizes depending on the application. The standard enclosure is 130x130x75 mm and weighs approx 0.7 kg complete with the battery. Pressure equalisation vents and other features to combat condensation may be fitted on request. 130 x 130 x 75 enclosure Nortech Management Ltd, United Kingdom Page 14 of 17
15 11. Specification Battery Life The standard lithium battery pack is a 3.9V, 32Ah unit. The drain on the battery is affected by a number of factors including: Power supply being provided for external 4-20mA sensors. Number and length of GSM modem calls and call attempts. Configuration settings for analogue input scan interval and stabilise time. Configuration of scan duration and fast scan period of digital inputs. Input wiring impedance. Temperature. It is therefore not possible to give a firm indication of the battery expectancy without knowing details of the application and configuration settings selected. As a rough guide a battery life of between 5 and 10 years is achievable. EMC Tests Independent EMC testing has been carried out on the NX21 product and passed to the following standards. Emissions EN EN55022 Radiated Emissions Immunity EN EN ESD EN Radiated Immunity EN Power Frequency Magnetic Field Environmental Enclosure Rating: Where supplied the enclosure is suitable for outdoor use. Humidity: 0-95% non condensing RTU PCB: -20 to +70 degrees C. Nortech Management Ltd, United Kingdom Page 15 of 17
16 12. Options and Accessories Transducer Power Supply Daughter Board The daughter board allows external 4-20mA transducers to be powered directly from the NX21. The 18V power supply output is switched by the NX21 processor and is usually synchronised with taking analogue readings. Note: The power daughter board requires a larger enclosure. The NX21 with modem and antenna, battery and daughter board can be supplied in an enclosure 180 x 182 x 90 mm. Analog Power Board Connections Nortech Management Ltd, United Kingdom Page 16 of 17
17 NXD8 1 in, 2 out daughter board The NXD8 requires a specific version of firmware to operate. Digital inputs 2-8 are not monitored when the NXD8 is fitted. The NX21 + NXD8 takes a single relay input, monitors it using digital input 1 and controls an output relay which can be wired to external equipment. The output relay is controlled by the NX21 to follows the status of the input relay. NXD8 Photo 1 Legend: 1: Plug into NX21 2: Output relay 3: Wiring for Input and Output relays 3 2 NXD8 Wiring connections Pin 1 Input Relay must be volt free Pin 2 Pin 3 Output Relay volt free Pin 4 NXD8 installed on NX21 3 Legend: 1: Input and Output Relay connections 2: M3 mounting screw 3: Additional mounting point if required. 4: LED and button still accessible Pin 4 Pin 3 Pin 2 Pin 1 1 Nortech Management Ltd, United Kingdom Page 17 of 17
APP 700 Technical Specification
Issued: 12/12 Supersedes: 4/12 Description The APP 700 hardware series are especially designed for waste and clean water systems, both in construction and functionality. The RTUs¹ are developed to meet
More informationGCU401. Technical specification
GCU401 Technical specification Flygt Gateway Control Unit GCU401 Product The Flygt GCU 401 is a robust ultra-low Gateway Control Unit/ Alarm Unit/Data Logger, configurable to fit a wide range of applications
More informationKAUGJUHTIMISSÜSTEEMID TELECONTROL SYSTEMS MODEM TELEM-GSM/GPRS 3G. User manual
KAUGJUHTIMISSÜSTEEMID TELECONTROL SYSTEMS MODEM TELEM-GSM/GPRS 3G User manual Martem AS 2014 CONTENTS 1. Description...3 2. Features...3 3. Interfaces...3 4. Indication and switches...4 4.1 State LED indication...4
More informationATU800. Technical specification
ATU800 Technical specification ATU800 Series Table of Contents Product... 5 Denomination... 5 Power Supply... 5 Internal Batteries... 5 DC Version... 5 AC Version... 5 Approved Standard... 5 Environment...
More informationCopyright Extract from Conditions of Sale Safety Warning
KD420 User Manual Copyright 2004-2013 KK Systems Ltd. No reproduction of any part of this document, in any form, is allowed without prior written permission from KKSystems Ltd. All other copyrights and
More informationMillenium 3. General Characteristics. General environment characteristics for CB, CD, XD, XR and XE product types
Millenium 3 General Characteristics Millenium 3 Compact Range Millenium 3 Expandable Range Millenium 3 Communication Options Millenium 3 Range General environment characteristics for CB, CD, XD, XR and
More informationUp to two expansion cards can be added; these cards may either add an additional 4 analogue or 8 digital inputs.
SA380TX-L Hardware The basic TX-L unit features: 4 digital inputs 2 analogue inputs 1 RS485 port 24v 2W auxiliary power supply GSM modem. An Ethernet port can be fitted as an option when ordering. Up to
More informationLCI User Manual mantracourt.com
LCI User Manual mantracourt.com LCI Load Cell Junction Box with Fault Monitor Contents Chapter 1 Introduction to the LCI... 2 Chapter 2 Installing the LCI... 3 Chapter 3 Setting up the LCI... 4 Sequence
More informationTRACKER 240 SERIES. Load Cell and Weighing Indicators. A Precision Measurement Instrument with Outstanding Features
TRACKER 240 SERIES Load Cell and Weighing Indicators A Precision Measurement Instrument with Outstanding Features TRACKER 240 SERIES INDICATORS Ratiometric Measurement Tare and Auto Transducer Excitation
More informationCT-Interface & IRIS Touch 600 Range Installation Manual
CT-Interface & IRIS Touch 600 Range Installation Manual Coopers I-ON Panel Range Version 2.0 Table of Contents 1 System Overview... 3 2 IRIS Touch 640 PCB Layout... 3 3 Connections for Coopers I-ON Panel
More informationLCI Load Cell Junction Box with Fault Monitor
LCI Load Cell Junction Box with Fault Monitor User Manual www.mantracourt.co.uk The LCI Load Cell Failure Alarm Manual Chapter 1 Introduction to the LCI...2 Chapter 2 Installing the LCI...3 Figure 2.1
More informationPM174 PM174 IEEE1159 ADVANCED POWER QUALITY ANALYZER. Features
PM174 IEEE1159 ADVANCED POWER QUALITY ANALYZER The PM174 is a compact, multi-function, three-phase AC powermeter and power quality analyzer specially designed to meet the requirements of users ranging
More informationINTEGRATED SYSTEMS AND CONTROL, INC. User s Hardware Manual. PCMNET V 7. xx
INTEGRATED SYSTEMS AND CONTROL, INC. User s Hardware Manual PCMNET V 7. xx INTEGRATED SYSTEMS AND CONTROLS, INC. PCMNET Users Manual Revised 2/4/2005 2003-2005 Integrated Systems and Control. Inc. PO Box
More informationDKG-210 UNIVERSAL INTERNET GATEWAY UNIT
DKG-210 UNIVERSAL INTERNET GATEWAY UNIT AC & DC SUPPLY VERSIONS DESCRIPTION The DKG-210 is designed for internet monitoring and control of industrial devices using different protocols through the RAINBOW
More informationicp 1000 Wireless GSM Based Remote Monitoring Unit for Transformer Rectifier Unit
icp 1000 Wireless GSM Based Remote Monitoring Unit for Transformer Rectifier Unit The GSM based remote monitoring unit icp 1000, for Transformer Rectifier (TR) monitoring, is a highly accurate, compact,
More informationGC 055. GSM Remote Monitoring. Operating and installation instructions
GSM Remote Monitoring Operating and installation instructions GC 055 GSM, GPRS Programmable Communicator Transmits input conditions/controls outputs Measures analogue data Access control system/dallas
More informationProData DATA LOGGER. Chapter 03 ProData data logger. Ethernet. Pulse inputs and Pulse outputs. Modbus-Ethernet gateway. Thermistor input.
ProData DATA LOGGER Ethernet Pulse inputs and Pulse outputs Modbus-Ethernet gateway Thermistor input Memory 32 MB Threshold value monitoring 139 Smart and compact: Save energy costs through the universal
More informationDM650TM SENSOR / WALL MOUNTED TEMPERATURE DISPLAY
DM650TM UNIVERSAL RTD OR THERMOCOUPLE INPUT BATTERY POWERED USB AND NFC INTERFACE ALARM RELAY / USER SET DISPLAY MESSAGES 5000 POINT DATA LOGGER INTRODUCTION The DM650TM battery powered indicator accepts
More informationMIRRIN. Multi-Channel Load Logger MODEL: LL400 User Manual 1 GETTING STARTED INTRODUCTION CONNECTIONS
Contents MIRRIN Multi-Channel Load Logger MODEL: LL400 User Manual 1 GETTING STARTED... 3 1.1 INTRODUCTION... 3 1.2 CONNECTIONS... 3 1.3 KIT 5 1.3.1 Accessories... 5 1.3.2 Options... 5 1.4 POWER MODES...
More informationRM6000 GPRS Modem / Router
User Manual Version 6.30 AMG Systems Ltd March 2013 3 The Omega Centre Stratton Business Park Biggleswade Bedfordshire, UK SG18 8QB Tel: 44 (0) 1767 600777 sales@amgsystems.com 1. Introduction 2. RM6000
More informationRTU TELEM MODULES TELEM-DO8, TELEM-DI24 and TELEM-AI12 (REMOTE TERMINAL UNIT)
RTU TELEM MODULES TELEM-DO8, TELEM-DI24 and TELEM-AI12 (REMOTE TERMINAL UNIT) USER S MANUAL Technical documentation, programming, installation and setup instructions, drawings 2001 Table of contents 1.
More informationMicro Motion Model 7950 and Model 7951 Signal Converters
Product Data Sheet PS-001316, Rev. B April 2013 Micro Motion Model 7950 and Model 7951 Signal Converters Micro Motion Model 7950 and Model 7951 signal converters are the perfect complement to Micro Motion
More informationG303 RIO (REMOTE I/O) AND LOW END RTU
G3 TECHNOLOGIES, INC. G303 RIO (REMOTE I/O) AND LOW END RTU USER DOCUMENTATION / FUNCTIONAL SPEC. Introduction: The G303 is one of several RIO (Remote I/O) products from G3 Technologies designed to fill
More informationEP/2 Installation Instructions
1 2 3 4 7 ENTER 0 5 6 8 9 CLEAR + - LOGIC ONE EP/2 EP/2 Installation Instructions DOC. #569011000 A 7/30/04 PRINTED IN U.S.A. Regulatory Compliance Safety This device has been tested and found to be in
More informationProData data logger. Ethernet. Pulse inputs and Pulse outputs. Thermistor input. Modbus-Ethernet gateway. Memory 32 MB. Threshold value monitoring
Ethernet Pulse inputs and Pulse outputs Modbus-Ethernet gateway Thermistor input Memory 32 MB Threshold value monitoring ProData data logger 1 Smart and compact: Save energy costs through the universal
More informationis then retained absolutely without interruption.
Page 1 of 11 DC UPS uninterruptible power supplies - DC UPS module 6 A Compact design, only 50 mm wide Simple DIN rail mounting Absolutely interruption-free buffering of mains failures through immediately
More informationMM-IM. Large works automation And data gateway. PRODUCT DATASHEET
MM-IM Large works automation And data gateway. PRODUCT DATASHEET The MM-IM is a Remote Telemetry Unit (RTU) that provides a wide range of interfaces and protocols to allow integration with any typical
More informationScannex rt.buffer Overview
Scannex rt.buffer Overview Operation The Scannex rt.buffer is a rugged, low power 3G (UMTS/HSPA+) remote telemetry unit providing a flexible solution in marine and harsh environmental conditions, with
More informationIntech Micro 2300-A8VI analogue input station MODBUS RTU slave application supplementary manual.
Intech Micro 2300-A8VI analogue input station MODBUS RTU slave application supplementary manual. MODBUS supplementary manual to the 2300-A8VI Installation Guide. The 2300 series stations are designed to
More informationZ-GPRS2-SEAL THE SIMPLEST REMOTE MANAGEMENT SYSTEM FOR UNIVERSAL APPLICATIONS GSM/GPRS DATALOGGER WITH BUILT-IN I/O S AND TELECONTROL FUNCTIONS
e & Designed GSM / GPRS ETHERNET SMTP HTTP MODBUS TCP-IP USB MODBUS RTU THE SIMPLEST REMOTE MANAGEMENT SYSTEM FOR UNIVERSAL APPLICATIONS www.seneca.it taly 100% ad I in GSM/GPRS DATALOGGER WITH BUILT-IN
More informationDupline. Data Logger. Types G , G Product Description. Ordering Key G Type Selection. Input/Output Specifications
Dupline Data Logger Types G 800 006, G 800 106 Product Description Programmable channel generator with optional built-in GSM Modem Event and time based data logging functions for digital, analog and counter
More informationRTU32S RTU32S Series Small Compact Utility RTU
RTU32S RTU32S Series Small Compact Utility RTU Data Sheet 40270 v1.05 / July 7th, 2014 INTRODUCTION Brodersen Small Compact RTU32S Series with RTU/PLC functionality. The RTU32S series is based on an embedded
More informationBlackbox Controllers:
Blackbox Controllers: Level measurement made simple Compact low cost intelligent controllers Will operate on all db transducers up to 40m range Solids, powders and liquids level measurement Separation
More informationTG Technical specifications
TG2-500 Technical specifications TBox TG2-500 Specifications SPECIFICATIONS Standard: 3 wires 4G Modem -4E: Europe -4N: North America Backup battery charger TG2-500: COMMUNICATION PORTS TG2-500-4E: COMMUNICATION
More informationIP68. Autarkic Data Loggers - MT-051 / MT-713 / MT-723
Autarkic Data Loggers - MT-051 / MT-713 / MT-723 Use in the most demanding environments These data loggers are designed for use in difficult to reach and widely distributed locations. In places where neither
More informationJUMO ecotrans ph 03 Microprocessor transmitter/ switching device for ph/redox voltage and temperature
Page 1/7 JUMO ecotrans 03 Microprocessor transmitter/ switching device for /Redox voltage and temperature with a 2-line LCD for mounting on a 35 mm DIN rail Brief description Depending on the configuration,
More informationDATRAN XL4 PLUS RTU Quick Start Guide
DOC-QSG-XL4-PLUS-RTU DATRAN XL4 PLUS RTU Quick Start Guide Configuring the XL4 Plus RTU The XL4 Plus RTU is configured using software called QTech Workbench. Connection to your PC is via a USB cable (Type
More informationLLR-MOD Modbus Light Level and Occupancy Sensor
Product sheet SN1.418 Type LLR-MOD LLR-MOD Modbus Light Level and Occupancy Sensor The LLR-MOD sensors are designed to measure Light Level (LUX) in the room spaces and have built-in RS485 Modbus communication
More informationPCS Ferguson 8000 Series Overview Manual. The PCS Ferguson 8000 Series brand is trademarked by PCS Ferguson.
The PCS Ferguson 8000 Series brand is trademarked by PCS Ferguson. These documents and materials are copyrighted by PCS Ferguson. 2016 All rights reserved. For information contact: PCS Ferguson 3771 Eureka
More informationThe TRSUN is the complete solution for the remote monitoring of photovoltaic plants.
The TRSUN is the complete solution for the remote monitoring of photovoltaic plants. Monitoring of inverters and string combiner boxes (up to 64 devices); Complete configuration of the monitoring system
More informationApplication. Characteristics RTU540. Data Sheet Communication Unit 560CMD11. Communication Unit 560CMD11
Data Sheet Communication Unit 560CMD11 Communication Unit 560CMD11 The SLC works as master for the RTU560 serial peripheral bus (I/O-Interface/ Wired-OR-Bus ). The MPU is responsible for the other tasks.
More informationXEELAS NODE MANUAL X-COM VERSION 1.0
This document is the official manual for the Xeelas LoRa Node. In this document, all the functions and technical specifications are described. X-COM VERSION 1.0 XEELAS NODE MANUAL Manual for Software version
More informationINSTALLATION MANUAL Z-UMTS
INSTALLATION MANUAL Datalogger HSPA + with built-in I/O, telecontrol functions, embedded UPS and advanced programming language EN SENECA s.r.l. Headquarters: Via Austria, 26 35127 PADOVA ITALY Phone +39.049.8705355-8705359
More informationApplication. Characteristics RTU560. Data Sheet Communication Unit 560CMD11. Communication Unit 560CMD11
Communication Unit 560CMD11 The SLC works as master for the RTU560 serial peripheral bus (I/O-Interface/ Wired-OR-Bus ). The MPU is responsible for the other tasks. The MPU handles the absolute time and
More informationSM100. On-Line Switchgear Condition Monitoring
On-Line Switchgear Condition Monitoring On-Line Switchgear Condition Monitoring Introduction Weis is a specialist company with over 40 years of experience in the commissioning, testing & maintenance of
More informationUSER MANUAL FOR GS100/GS1003G
USER MANUAL FOR GS100/GS1003G 1 Table of Contents 1. INTRODUCTION... 3 2. FEATURES... 3 3. OPERATION... 3 4.CONNECTION DETAILS... 4 5.CONFIGURATION... 5 5.1 Hyper Terminal Setting... 5 5.2 GS100 Configuration...
More informationgridcomm GC1310 Master Light Controller Hardware Installation Guide
gridcomm GC1310 Master Light Controller Hardware Installation Guide GC1310 GC1318 Non LoRA option LoRA option GridComm Pte. Ltd. Page 1 of 16 GC-Net and the gridcomm logo are trademarks of gridcomm Pte
More informationHAT560NC SERIES (HAT560NC /HAT560NBC) ATS CONTROLLER USER MANUAL
HAT560NC SERIES (HAT560NC /HAT560NBC) ATS CONTROLLER USER MANUAL SMARTGEN (ZHENGZHOU) TECHNOLOGY CO., LTD. Chinese trademark English trademark SmartGen make your generator smart SmartGen Technology Co.,
More informationWall-/Pipe Mounted Universal Process Indicator
Data Sheet SS/_8 Wall-/Pipe Mounted Universal Process Indicator High visibility LED display the clearest view of your process status 0.1% measurement accuracy precise indication of process measurement
More informationSCADAPack 312E 313E. Smart RTUs for water
SCADAPack 312E 313E Smart RTUs for water 1 SCADAPack 312E and 313E Smart RTUs feature 32-bit processing, serial and US communications, integrated 12-30Vdc power supply, advanced power-management and a
More informationM1000 INTELLIGENT ZONE CONTROL SYSTEM
HARDWARE GUIDE DIMENSIONS & SPECIFICATIONS REV. 5.2 M1000 INTELLIGENT ZONE CONTROL SYSTEM ROOFTOP CONTROLLER 2 Table of Contents GENERAL INFORMATION... 3 PL-M1000 Rooftop Controller...3 Description...3
More informationT600 TACHOMETER MultiTasker - a measurement & monitoring instrument with 2 frequency and 1 analog inputs
TACHOMETER MultiTasker - a measurement & monitoring instrument with 2 frequency and 1 analog inputs Features High accuracy speed measurement: 0.002% for limits and 0.1% referenced to 20 ma 2 frequency
More informationMillenium II +: general characteristics
Millenium II +: general characteristics Starter kit Blind Temperature sensors Special starter kits Bare board Power supply Level detection Local extensions Accessories Standard Expandable Adjacent extensions
More informationBus Connection Unit 560BCU04
Bus Connection Unit 560BCU04 Application The Bus Connection Unit 560BCU04 R0001 is designed to make the RTU560s TSI, TSO, Alarm and Warning signals accessible to the outside. By using the bus connection
More informationECS ecompass Series. ECS ecompass Series. Strap down Electronic Compass. General Description. Features. Making Sense out of Motion
ECS ecompass Series Strap down Electronic Compass General Description Features High Accuracy Heading within 0.5 or better Tilt within 0.2 or better Wide Operating Range ±42 Pitch and Roll ±80 Dip angle
More informationOMNICOMM ON-BOARD TERMINALS
ON-BOARD TERMINALS QUALITY, RELIABILITY, PRECISION On-board terminals are a critical component of effective fleet management. They collect data from various sensors and the vehicle s on-board computer
More informationGSM communicator GD-06 Allegro Complete manual
GSM communicator GD-06 Allegro Complete manual The GD-06 ALLEGRO is a universal GSM dialer and controller. It can be used for both home and industrial automation purposes, for security applications or
More informationTHANK YOU FOR VOTING TEXECOM INSTALLATION MANUAL. Digi-modems. Issue 3
THANK YOU FOR VOTING TEXECOM INSTALLATION MANUAL Digi-modems Issue 3 Contents Com300 & Com2400 Installation Manual Contents 1. Regulatory Requirements... 3 General...3 Approval... 3 REN Rating... 3 2.
More informationProduct and Applications Description. Note. Example of Operation. Installation Instructions. Application Programs WARNING
Product and Applications Description Note If the application program is not loaded completely by the ETS, you had better interrupt the 24 V voltage supply of the I/O-module during the loading interval.
More informationTECHNICAL SPECIFICATION OF GPRS based MODEM (Part 1)
TECHNICAL SPECIFICATION OF GPRS based MODEM (Part 1) 1. SCOPE: The scope of work is on turn-key basis covering modem supplies, solution engineering. Supply of GPRS Modems for data acquisition from HT/
More informationNetbiter EC300 Series
Netbiter EC300 Series USER MANUAL SCM-1202-012 2.2 ENGLISH Important User Information Liability Every care has been taken in the preparation of this document. Please inform HMS Industrial Networks AB of
More informationRS-485 Fiber-Optic Link RS-485 to Multi-Mode Fiber-Optic converter ST Fiber Connectors DIN Rail Mount
Fiber-Optic Link to Multi-Mode Fiber-Optic converter ST Fiber Connectors DIN Rail Mount 101-0079 Installation Operation & Specifications Manual Auto-direcon control Supports BAUD rates up to 115,200 Fiber
More informationProduct Description. Contents. Fusion Series. New Information December 2003
Fusion Series Technical Data New Information December 2003 Durant Fusion Product Description The Durant Fusion from Eaton Electrical is an industrial control unit consisting of a high speed count control
More informationThe Programmable 4-Way Relay Card is an optional peripheral unit that provides four individually programmable relay output circuits.
Peripheral Relay The Programmable 4-Way Relay Card is an optional peripheral unit that provides four individually programmable relay output circuits. Up to 16 Cards can be connected to a multi-loop panel
More informationGSM-X. Communication module. Quick installation guide. Full manual is available on Firmware version 1.02 gsm-x_sii_en 08/18
GSM-X Communication module Quick installation guide Full manual is available on www.satel.eu Firmware version 1.02 gsm-x_sii_en 08/18 SATEL sp. z o.o. ul. Budowlanych 66 80-298 Gdańsk Poland tel. +48 58
More informationCLIMATIX STEQ, STCM DATASHEET FOR CONTROLLING, SWITCHING AND MONITORING FUNCTIONS. POWER SUPPLY RELAY OUTPUTS. Power supply. 4.
CLIMATIX STEQ, STCM DATASHEET FOR CONTROLLING, SWITCHING AND MONITORING FUNCTIONS. 4. Relays Power supply 2. Relays 8. Universal Inputs/ Process Bus (KNX) RS485 (Modbus) Tool (USB) Ethernet Tool (USB)/
More informationREQUIREMENTS FOR WIRELESS, WEB-BASED MONITORING EQUIPMENT AND SERVICES FOR PUMP STATION APPLICAITONS
REQUIREMENTS FOR WIRELESS, WEB-BASED MONITORING EQUIPMENT AND SERVICES FOR PUMP STATION APPLICAITONS MANUFACTURER REQUIREMENTS The Manufacturer of the equipment and provider of related services shall provide
More informationMEITRACK T333 User Guide
MEITRACK T333 User Guide Change History File Name MEITRACK T333 User Guide Created By Owen Cheng Project T333 Creation Date Update Date 2014-06-10 2017-04-06 Subproject User Guide Total Pages 16 Version
More informationC160 Wall-/Pipe Mounted Universal Process Indicator
Data sheet DS/ EN Rev. I Wall-/Pipe Mounted Universal Process Indicator reliable process indicator, wherever it s needed High visibility LED display the clearest view of your process status 0.1% measurement
More informationFIFOTRACK MOTORCYCLE/VEHICLE GPS TRACKER
FIFOTRACK MOTORCYCLE/VEHICLE GPS TRACKER Model: S20 Version: V1.1 www.fifotrack.com Copyright and Disclaimer All copyrights belong to Shenzhen fifotrack Solution Co., Ltd. You are not allowed to revise,
More informationOn-board wireless temperature and humidity logger
On-board wireless temperature and humidity logger v6.3 BT 1 Contents 1. Introduction... 4 2. Description of the operation... 4 3. Technical data... 6 4. Loggicar R package contents... 7 5. Logger overview...
More informationRS-485 MicroLinK HM Setup Software Installation Operation & Specifications Manual
RS-485 MicroLinK HM RS-485 HART Protocol Modem HART Device to Modbus Accumulator DIN Rail Mount 101-0035 Setup Software Installation Operation & Specifications Manual The RS-485 MicroLink-HM 101-0035 is
More informationSKF Multilog On-line System IMx-8. 24/7 condition monitoring to improve machine reliability
SKF Multilog On-line System IMx-8 24/7 condition monitoring to improve machine reliability SKF Multilog On-line System IMx-8 The SKF Multilog On-line System IMx-8 is a powerful solution for condition monitoring
More informationEnergy Client. Version Feb Electrocom Rødeledsvej 95 DK-5700 Svendborg Denmark Tel:
Energy Client Version 2.0.806 3. Feb. 2014 Electrocom Rødeledsvej 95 DK-5700 Svendborg Denmark Tel: +45 88 80 75 80 www.electrocom.dk p. 2 Introduction... 3 Installation... 4 LED, Switches and Reset...
More informationRTU32S RTU32S Series Small Compact Utility RTU
RTU32S RTU32S Series Small Compact Utility RTU Data Sheet 40270 v1.03 / February 10th, 2013 INTRODUCTION Brodersen Small Compact RTU32S Series with RTU/PLC functionality. The RTU32S series is based on
More informationUCM 94/1 3G/GPRS Modem for RTU32 Series
UCM 94/1 3G/GPRS Modem for RTU32 Series Data Sheet 40332 v1.00 / May 1 st, 2013 INTRODUCTION UCM 94/1 is an industrial 3G/UMTS/GPRS Modem designed for use with the Brodersen RTU32 Series. The UCM 94 support
More informationTinytag Re-Ed Volt/mV/mA and Count Manual
Gemini Data Loggers Tinytag Re-Ed Volt/mV/mA and Count Manual The name TINYTAG covers a range of miniature light-weight dataloggers used to aid the collection and monitoring of data. Tinytag Re-Educatable
More informationX-18s Users Manual. X-18s User Manual Revisions Revision Description Initial release. Xytronix Research & Design, Inc.
X-18s User Manual Revisions Revision Description 1.0 Page 2 Initial release Introduction Section 1: Introduction The X-18s expansion module is used with the X-600M controller. The X-18s has ten, high-current
More informationMX-1 GSM/GPRS M-BUS DATA LOGGER USER MANUAL
MX-1 GSM/GPRS M-BUS DATA LOGGER USER MANUAL JSC VILTRUS K. Donelaičio str. 62, Kaunas, Lithuania Phone: +370 640 65040 E-mail:sales@viltrus.com Web: www.viltrus.com CONTENTS 1 Abbreviations and explanations...
More informationPK2200 Series. Features. C-Programmable Controller. Specifications Board Size Enclosure Size Operating Temp.
C-Programmable Controller P00 Series The P00 Series of C-programmable controllers is based on the Zilog Z80 microprocessor. The P00 includes digital, serial, and high-current switching interfaces. The
More informationHardware manual. 1. Overview 2. Technical characteristics 3. Connections. ( Portal (../portal/portal.html)
1 (http://nethix.com) Portal (../portal/portal.html) WE110 (../we110/we110.html) WE120 (../we120/we120.html) WE300 (../we300/we300.html) WE500 (we500.html) Quick start guide (we500_qsg.html) Hardware manual
More informationiologik 2500 Series Quick Installation Guide
iologik 2500 Series Quick Installation Guide Smart Remote I/O Edition 5.0, December 2016 Technical Support Contact Information www.moxa.com/support Moxa Americas: Toll-free: 1-888-669-2872 Tel: 1-714-528-6777
More information2G / 3G DATALOGGERS. Submersible enclosure. Up to 6 year battery life. Easy installation. Flexibility.
2G / 3G DATALOGGERS Submersible enclosure Up to 6 year battery life IP67 or IP68 protected enclosure for hostile environments Powered by a 7,2V & 28Ah battery connector for external power supply Flexibility
More informationMEITRACK MVT340 User Guide
MEITRACK MVT340 User Guide Change History File Name MEITRACK MVT340 User Guide Created By Kyle Lv Project MVT340 Creation Date Update Date 2010-08-24 2017-03-23 Subproject User Guide Total Pages 12 Version
More informationModel SFS01-V2 IMPORTANT! MULTI-ATTEMPT AUTOMATIC ENGINE SMART SWITCH
MULTI-ATTEMPT AUTOMATIC ENGINE SMART SWITCH Model SFS01-V2 DESCRIPTION The Model SFS01-V2 is a Multi-attempt Automatic Engine Smart Switch designed to automatically [remotely] or manually start and stop
More informationDEEP SEA ELECTRONICS PLC
COMPLEX SOLUTIONS MADE SIMPLE. DEEP SEA ELECTRONICS PLC DSE4130 AUTOMATIC TRANSFER SWITCH CONTROL MODULE OPERATING MANUAL Deep Sea Electronics Plc Highfield House Hunmanby North Yorkshire YO14 0PH ENGLAND
More informationDinBox M36 Hardware Description Guide
DinBox M36 Hardware Description Guide This manual covers the different hardware settings when using the DinBox M36 equipment. Next to this you will find all the relevant technical information needed when
More informationProduct Catalog. Belgium Tel.: +32 (0) The Netherlands Tel.: +31 (0)
Product Catalog Table of Contents NGR-30 Gateway ZEM-61 Wireless 3-Phase Electricity Monitor ZEM-30 Wireless Single Phase Electricity Monitor TES-11 / HTS-10 Wireless Temperature / Humidity Sensor TES-21
More informationCA-A480-A Elevator Controller. Reference & Installation Manual
CA-A480-A Elevator Controller Reference & Installation Manual TABLE OF CONTENTS INTRODUCTION.................................................................. 4 Introduction.............................................................................................
More informationSingle and Double pole relays rated for 20 amps 120, 230, 277, and 347 volts
Contact Relay Panels come in panel sizes of 12, 24, 36, 42, and 48 relay variants. Contact Relay Panels are ideal for a wide range of control and energy management applications. The system s integrated
More informationManual# Installation Manual. 200E Series. DCU 210E/208E Engine Panel RP 210E/220E Remote Panel
Manual# 1006495 Installation Manual 200E Series DCU 210E/208E Engine Panel RP 210E/220E Remote Panel Installation Manual for the Marine Pro 200E Series ~~~ DCU 210E/208E Diesel Engine Control Unit RP 210E/220E
More informationVT825 / Environmental Monitoring unit. Environmental Infrastructure monitoring
Environmental Infrastructure monitoring VT825 / Environmental Monitoring unit The unit is used for IT environmental control in data-centers, remote facilities, offices, industrial facilities & remote shelters.
More informationEZmoto V4.1 Product description Rev. 2 30/07/2015
EZmoto V4.1 Product description Rev. 2 30/07/2015 1 Contents 1. Overview... 3 2. Hardware Interface Description... 3 2.1 Main features of the EZmoto... 3 2.2 Hardware block diagram... 4 2.3 Internal Hardware
More informationSR2B202BD compact smart relay Zelio Logic - 20 I O - 24 V DC - clock - display
Characteristics compact smart relay Zelio Logic - 20 I O - 24 V DC - clock - display Main Range of product Product or component type Complementary Local display Number or control scheme lines Cycle time
More informationComTroll 120 GLM GSM modem for sending SMS alarms from LineTroll fault Indicators
ComTroll 120 GLM GSM modem for sending SMS alarms from LineTroll fault Indicators User Manual For software versions from 2.22 and newer Page 1 This document describes the COMTROLL 120 GSM Communication
More informationPTU300 Combined Pressure, Humidity and Temperature Transmitter
PTU300 Combined Pressure, Humidity and Temperature Transmitter For Demanding Applications Features Barometric pressure, humidity, and temperature measurement in one transmitter RS-232C serial interface
More informationGSM/GPS/GPRS Vehicle/Motorcycle Motorbikes Tracking. User Manual V7.0
GSM/GPS/GPRS Vehicle/Motorcycle Motorbikes Tracking User Manual V7.0 Introduction Notes (ASICO INDUSTRIAL) 2005 Every effort has been made to ensure that the contents of this booklet are correct. However,
More informationPoseidon 4002 MANUAL
Poseidon 4002 MANUAL Poseidon 4002 MANUAL POWER input 12VDC supply (jack or terminals) INPUTS Binary inputs 1 6 (for contacts) OUTPUTS Two 50V rated switchover relay contacts ETHERNET 10 or 100/10 Mbps
More informationHouseLink HL-10E. Installation and Operation Manual Modbus TCP and XML
HouseLink HL-10E Installation and Operation Manual Modbus TCP and XML HouseLink HL-10E 4/25/2018 Table of Contents Installation Overview... 3 Components... 3 BinTrac Indicator... 3 Load Cell Bracket...
More informationInstallation Manual for D1800 Series High Power PoE Midspan Power Supply
Installation Manual for D1800 Series High Power PoE Midspan Power Supply Dycon Power Solutions Ltd Tel: +44 (0)1443 471 900 Unit A - Cwm Cynon Business Park Mountain Ash CF45 4ER - UK www.dyconpower.com
More information