Telrad CPE 7000 Outdoor Customer Premise Equipment Installation

Size: px
Start display at page:

Download "Telrad CPE 7000 Outdoor Customer Premise Equipment Installation"

Transcription

1 Telrad CPE 7000 Outdoor Customer Premise Equipment Installation Version: 1.2 Publication Date: 09-June-14

2 Revision History Date Version Description of Changes 25-April First release. 15-May Second revision 09-June Final Version Contents 1. Overview Introduction to the Telrad CPE Telrad CPE 7000: As Shipped... 4 Telrad CPE Error! Bookmark not defined. Telrad CPE 7000 ODU Status LEDs... 6 Telrad CPE 7000 IDU... 7 Static IP Addresses Mounting the Telrad CPE 7000 ODU Installing the Telrad CPE 7000 Cables and Grounds Approved and Unacceptable Building Ground Points Surge Suppressor Connecting the Surge Suppressor to the Building Ground Installing Cable & Ground from Surge Suppressor to ODU, Part Installing Cable & Ground from Surge Suppressor to ODU, Part Installing Cable from Surge Suppressor to IDU Connecting to a Computer, and Power Aligning the Telrad CPE Rescanning for Base Stations WMI State Parameter Alignment Options Alignment using the ODU LEDs Alignment using the WMI Quality of Installation Parameters Acceptance, Part Identifying the Base Station WiMAX Telrad CPE 7000 Installation 2

3 6. Connecting Your Customer s Computer to the CPE Overview The WiMAX Telrad CPE 7000 Installation guide is a supplement to the WiMAX Customer Premise Equipment Installation guide. It covers material specific to the Telrad CPE 7000 for Installers of Xplornet s WiMAX service. Refer to the WiMAX Customer Premise Installation guide for information about: Preparing for a site visit Performing a site survey General mounting guidelines and requirements Service activation Quality of Installation parameters Safety standards Refer to this guide for information about: Telrad CPE 7000 components, interfaces, and indicators Telrad CPE 7000 support for static IP addresses Telrad CPE 7000 mounting instructions Telrad CPE 7000 cabling and grounding Telrad CPE 7000 alignment Connecting your customer s computer to the Telrad CPE 7000 WiMAX Telrad CPE 7000 Installation 3

4 2. Introduction to the Telrad CPE 7000 Telrad CPE 7000: As Shipped The Telrad CPE 7000 is shipped in one box that contains: The outdoor unit, or ODU The indoor unit, or IDU A pole mounting kit IDU ODU Contents may not appear exactly as shown. WiMAX Telrad CPE 7000 Installation 4

5 Telrad CPE 7000 The Telrad CPE 7000 ODU incorporates: A modem for communications with the IDU Data processing and management software A high-gain antenna A radio transmitter/receiver for communications with the base station. The CPE is termed a dual-mode CPE because the radio can communicate with a base station via either the WiMAX or LTE standard. An integrated analog telephone adapter, or ATA. There is one RJ 11 phone port ( ): Provides a phone line from the ODU to the POE Adapter. The POE adapter has two RJ 11 ports to connect to the customer s phone. Note: at this time, the phone capabilities of the CPE7000 are not supported. The 100 BaseT ( ) port: o Supports Ethernet communications with the IDU o Supports a Power over Ethernet, or POE, connection the IDU supplies -56VDC over this link to power the ODU The ground screw: Connects the ODU to an approved building ground point. Grounding details are provided later in this document. Status LEDs: are covered in the next topic. The ODU can be located: Up to 18mi or 30km from the base station Up to 295ft or 90m from the IDU The total Ethernet run from ODU to the customer's equipment cannot exceed 328ft or 100m. WiMAX Telrad CPE 7000 Installation 5

6 Telrad CPE 7000 ODU Status LEDs There are 6 LED on the CPE 7000, three top LEDs provide the status of the CPE and three bottom LEDs provide the status of the link. When power is applied to the ODU, all the status LEDs light and a built-in test, or BIT, starts. When the BIT finishes, the blue LED in the upper left corner will come on which is the main power. The Yellow middle status led, TBD The green status LED on the upper right indicates if the Subscriber Identity Module (SIM) card is present. The SIM required for proper CPE operation and is used for LTE. Do not remove or exchange this card. LED Name Location Colour LED Behaviour Status Indication LED List Main Power Blue ON Power On OFF Power Off TBD Status Yellow Steady On TBD Blinking TBD Off TBD SIM Status Green Steady On SIM Detected Blinking when On- PUK/PIN Code Hook Off No SIM Detected The bottom three LEDs indicate the CINR of the signal after the CPE is connected to a base station. 4G Status LED: Link Status LED Behaviour and meaning 4G 1 Red Steady On CINR < 8dB 4G 2 Red/Yellow Steady On 8dB <CINR < 24dB 4G 3 Red/Yellow /Green Steady On 24dB <= CINR WiMAX Telrad CPE 7000 Installation 6

7 Telrad CPE 7000 IDU The Telrad CPE 7000 IDU comprises an AC adapter and a Power over Ethernet, or POE, adapter. The POE adapter is hard-wired to the AC adapter and has four ports: RJ-45 port labelled "TO/FROM OSU POE (RJ45)": o Supports a 100 BaseT Power over Ethernet link to the ODU o Sends and receives control signals to and from the ODU o Supplies power to the ODU NOTE: The BreezMAX PRO 6000 and CPE 7000 POE adaptors are not interchangeable Be very careful to connect ONLY the ODU to the POE port. The -56VDC can destroy customer equipment in milliseconds. RJ-14 port labelled TO/FROM OSU VOIP (RJ14) o Provides connection to the ATA in ODU with a phone line. The telephone can be used for VoIP services, if available. RJ-11 ports labelled 1 and 2 : Provides a connection from the IDU to up to two telephone set. The POE adapter Ethernet cable. The POE adapter has a built in Ethernet cable that goes from the adapter to the customer equipment such as a PC or router. WiMAX Telrad CPE 7000 Installation 7

8 Static IP Addresses Consider the following if the customer has ordered a static IP address: Static IP addresses are supported on the Telrad CPE 7000 Only one static IP is supported per CPE Use DHCP for all installation activities, up to and including service activation When service activation is complete, call the Dealer Support Group ( ) who work with you or the customer to configure the customer s computer for static IP To access the WMI once a CPE is provisioned with a static IP, you must configure your computer to use a static IP address: use a static IP in the range x (where x is greater than 1), a subnet mask of , and a default gateway of WiMAX Telrad CPE 7000 Installation 8

9 3. Mounting the Telrad CPE 7000 ODU Consider these points before mounting the Telrad CPE 7000: The ODU can be mounted on a J-arm platform, a tripod, or a ground pole using the mounting kit. The pole mounting kit can be used on poles whose diameter ranges in size from 1 to 4in or 2.5 to 10cm. The ODU must be mounted so that the sides are at a 45 angle with the pole; that is, so that the ODU looks like a diamond, not a square, when seen from the ground. The pole mounting kit is designed to provide the required 45 if and only if the pole is plumb. Any mast over 10ft or 3m must be guyed at three points. WiMAX Telrad CPE 7000 Installation 9

10 In most cases, it is easiest to attach the kit to the ODU before climbing to the mounting location. Referring to the illustration: 1. Spin a nut up the bolt until it reaches the head of the bolt. Repeat for the other bolt. 2. Slide a spring washer up to the nut. Repeat for the other bolt. 3. Slip the bolt through the hole in the pole-mount bracket and thread it into the ODU. Repeat for the other bolt. 4. Snug the bolts down. Do not over-tighten. 5. The model with have a round head ground screw; connect 12AWG ground wire to the ODU ground screw before mounting because the ground screw is not accessible once the ODU is mounted. Refer to Installing Cable and Ground from Surge Suppressor to ODU, Part 2 for details about grounding the ODU. 6. Once the mounting platform is installed, slip the ODU over the top of the pole and slide it into position. In general, mounting the ODU as high as possible usually provides the best signal quality. 7. Hold the ODU at the desired location on the pole and tighten the lock nuts sufficiently so that the ODU is held firmly, but you can still rotate it around the pole. WiMAX Telrad CPE 7000 Installation 10

11 4. Installing the Telrad CPE 7000 Cables and Grounds The diagram illustrates the wiring plan for the Telrad CPE 7000 CPE. The tasks you need to carry out to complete the wiring plan are listed below. Detailed instructions are provided in following topics. In all topics, cable is synonymous with Cat5e cable. In the diagrams, the Cat5e cable is shown as red for illustrative purposes only. Task List 1. Confirm that the mount location satisfies all requirements listed in the Location Requirements Checklist. 2. Review the grounding standards. 3. Install a surge suppressor. 4. Install a ground wire from the surge suppressor to an approved building ground point. 5. Install a Cat5e cable (with ground wire) between the surge suppressor and the ODU. WiMAX Telrad CPE 7000 Installation 11

12 6. If you are using a J-arm platform, install a dual ground lug on the mast bracket. If you are using a tripod or ground pole, install two ground straps on the pole, a hand's width apart. 7. Install a ground between the surge suppressor and the dual ground lug, or the lower ground strap. 8. Install a ground between the ground screw on the ODU and the dual ground lug, or the upper ground strap. 9. Install a Cat5e cable between the surge suppressor and the IDU. 10. There are two options for aligning the ODU: using the LEDs on the ODU, or using the Web Management Interface. Details about each alignment option are covered later in this document. Your choice determines the final cabling requirements: If you intend to use the LEDs on the ODU, then no more cabling is required. If you plan to use the Web Management Interface, install an Ethernet cable between the IDU POE adapter and your computer. 11. Power up the IDU. When all tasks are complete, you are ready to align the ODU. WiMAX Telrad CPE 7000 Installation 12

13 Approved and Unacceptable Building Ground Points A list of approved and unacceptable ground points is repeated here because the importance of proper grounding cannot be over-emphasized. Review the previous grounding topics for details. Approved ground points are: A building ground, also called an electrical service electrode. Service equipment enclosures. Never drill into an electrical service panel. A metal conduit or raceway of the electrical service. A grounded interior metal water pipe. An I-beam clamp on a grounded structural steel member. Unacceptable ground points are: Conduit on the load side of a building enclosure A cut-off switch or a condensation pipe on a Heating Ventilation Air Conditioning, or HVAC, system Steel roof trusses Metal roofs, metal roof screws, metal screens, or metal windows Vents or vent pipes Electrical outlets or light fixtures Gas pipes, gutters, exterior water faucets, unlicensed ground rods WiMAX Telrad CPE 7000 Installation 13

14 Surge Suppressor 1. Mounting holes These holes can be used for mounting the Surge Suppressor unit to a flat surface such as an outside wall. The distance between the centers of the holes is 4.25 inches (108mm). 2. RJ-45 connectors One side connects to the 7000 CPE, the other side connects to the AC adaptor s Ethernet connector. 3. Ground post use heavy gauge (12 AWG or 6 mm²) copper wire for connection. 4. Ground cable opening Route the 12 AWG (6 mm²) ground cable through this opening. 5. CAT-5 cable knockouts Route the two CAT-5 cables through these openings. 6. Conduit knockouts Two large knockouts, located on the back of the case near the bottom, are available for installations where cable is to be routed through building conduits. WiMAX Telrad CPE 7000 Installation 14

15 Connecting the Surge Suppressor to the Building Ground To connect the surge suppressor to the building ground: 1. Locate an approved building ground point: The surge suppressor must be installed within approximately 20ft or 6m of the building ground point. The distance refers to the total wire length, not the straight-line path. 2. Fasten the surge suppressor to a solid surface, as close to the planned point of entry as possible. 3. Connect Xplornet-approved 12AWG ground wire to the building ground point. 4. Run the wire to the surge suppressor. Run the wire along horizontal and vertical paths, keeping it out of sight as much as possible. Avoid sharp bends. Use Xplornet-approved single cable clips every 24in or 60cm to secure the wire to the building. 5. Cut the wire so that it can reach through ground cable opening to the nut on the same side. 6. Strip away about 1in or 3cm of insulation. WiMAX Telrad CPE 7000 Installation 15

16 7. Pass the wire through the ground cable opening. 8. Loosen the nut and wrap the stripped wire clockwise around the post, between the two washers. 9. Tighten the nut. WiMAX Telrad CPE 7000 Installation 16

17 Installing Cable & Ground from Surge Suppressor to ODU, Part 1 To install Ethernet cable and ground from the surge suppressor to the ODU: 1. The approved Cat5e Ethernet cable with integrated ground wire is available in three pre-terminated lengths: 50ft or 15m, 75ft or 23m, and 125ft or 38m. Though cable with integrated ground wire is recommended, you can use an equivalent cable without ground. In this case, use Xplornet-approved 12AWG ground wire in place of the integrated ground wire. Measure the distance between the surge suppressor and ODU and select the cable with the best fit. Measure along horizontal and vertical paths, but avoid sharp bends. Cutting and re-terminating the Cat5e cable is not allowed. 2. At the surge suppressor, separate a few inches of the integrated ground wire from the Cat5e cable. 3. Strip away about 1in or 3cm of insulation from the ground wire (either the integrated wire or a separate 12AWG ground wire). WiMAX Telrad CPE 7000 Installation 17

18 4. Plug the Cat5e cable into the left RJ-45 port. Make sure to remove the Cat5 cable knockout. 5. Loosen the nut on the ground terminal and wrap the stripped wire clockwise around the post, between the two washers. 6. Tighten the nut. 7. Run the cable to the ODU. Run the cable along horizontal and vertical paths, keeping it out of sight as much as possible. Avoid sharp bends. Use Xplornet-approved single cable clips every 24in or 60cm to secure the cable and integrated ground wire to the building. If you are using Xplornet-approved 12AWG ground wire rather than an integrated wire, use single cable clips on both the cable and wire. 8. Run the cable to the ODU POE port ( ). 9. Coil any excess Cat5e cable. When all connections have been made, secure the coil as close to the ODU as is practical. 10. At the ODU POE port, use an adjustable wrench to remove the sealing gland assembly from the ODU body. Referring to the illustration, the sealing gland assembly includes: o Sealing gland base (1) o Rubber bushing (2) o Sealing gland nut (3) o Sealing gland plug Keep the assembly warm until you are ready to reinstall it. The parts are difficult to work with when cold. WiMAX Telrad CPE 7000 Installation 18

19 The assembly must be reinstalled to weatherproof the ODU. However, it is often easier to wait until after you have aligned the ODU. Until then, plug the Cat5e cable directly into the POE port. 12. When you are ready to reinstall the sealing gland assembly: A. Remove the sealing gland plug and discard it. B. Remove the sealing gland nut from the sealing gland base. C. Push the rubber bushing out of its retainer in the sealing gland base. Push from the ODU side of the sealing gland base. D. Thread the sealing gland nut and sealing gland base over the Cat5e cable, in the order shown in the illustration. E. Reinstall the sealing gland base on the ODU. Do not over-tighten. F. Plug the Cat5e cable into the POE port. G. Fit the rubber bushing around the cable, between the sealing gland nut and the sealing gland base. The bushing is split to its center along its length to allow this fit. When using Cat5e cable with integrated ground wire, separate the integrated ground wire to the Dual Ground lug or the top ground strap if doing a pole or tripod mount. H. Push the rubber bushing along the cable and back into its retainer in the sealing gland base. This is a snug fit and may require some patience. I. Reinstall the sealing gland nut. Hand tight only, but firmly: you are sealing the unit. 13. Continue to Part 2 of this procedure which covers installation of the ground wires at the ODU. WiMAX Telrad CPE 7000 Installation 19

20 Installing Cable & Ground from Surge Suppressor to ODU, Part 2 In Part 1 of this procedure, you connected the Cat5e cable and ground wire to the surge suppressor, ran the cable and wire to the ODU, and connected the cable to the POE port of the ODU. In Part 2, you install the ground wires at the ODU. These instructions are designed to ground the ODU and the mounting platform, as required by the Canadian Electrical Code. 14. For a J-arm platform, install a dual ground lug at the J-arm mast bracket. Before fastening the dual ground lug to the mast bracket, scrape some paint from the area where the dual ground lug makes contact to ensure a good electrical connection. For a pole mount platform, install two ground straps around the pole, near the ODU, about a hand's width apart. Ensure that the ground strap material is the same as the pole material (galvanized steel, for example). A metal mismatch can cause a galvanic reaction that corrodes the metal. 15. Run Xplornet-approved 12AWG ground wire from the ground screw on the ODU to one of the terminals on the dual ground lug, or to the upper ground strap. As noted when you mounted the ODU, you must connect the ground wire to the ground screw before mounting the ODU. 16. Tighten the screws to secure the wire at both ends. 17. When using Cat5e cable with integrated ground wire, separate the ground wire from the cable back to the dual ground lug, or to the lower ground strap. 18. Cut the integrated ground wire or the 12AWG ground wire from the surge suppressor, to an appropriate length for connecting to the dual ground lug or lower ground strap. It is good practice to cut the wire about 6in or 15cm longer than the minimum required. 19. Strip about 1/2in or 1 cm of insulation from the wire. WiMAX Telrad CPE 7000 Installation 20

21 20. Insert the stripped wire into the unused terminal of the dual ground lug, or in the terminal of the lower ground strap. 21. Tighten the terminal screw. 22. Secure the Cat5e cable and ground wire to the mounting platform using cable ties every 6in or 15cm. WiMAX Telrad CPE 7000 Installation 21

22 Installing Cable from Surge Suppressor to IDU To install Cat5e cable from the surge suppressor to the IDU: 1. The Cat5E cable for the run from the surge suppressor to the IDU does not require a ground wire. Xplornet-approved Cat5e cable for the run to the IDU is available in three pre-terminated lengths: 25ft or 7.5m, 50ft or 15m, and 75ft or 23m. Measure the distance between the surge suppressor and IDU and select the cable with the best fit. Remember to allow for a drip loop. Cutting and re-terminating the Cat5e cable is not allowed. 2. At the surge suppressor, plug the Cat5e cable into the right RJ-45 port. a. Make sure to the Cat5 Cable Knockout is removed as illustrated in diagram above b. If installing where cable is being routed through building conduit, remove the Conduit Knock (6) at back of surge suppressor. If this method is use, do not remove the Cat5 Cable Knockout (5). 3. Run the cable to the point of entry, creating a U-shaped drip loop at the point of entry. 4. Feed the cable through the point of entry and on to the IDU location identified by the customer. WiMAX Telrad CPE 7000 Installation 22

23 As much as possible, run the cable so that it is straight and out of sight. Avoid sharp bends. Use Xplornet-approved single cable clips every 24in or 60cm to secure the cable to the building. 5. Coil excess cable inside the building, in an out-of-the-way location, preferably out of sight. 6. Unpack the IDU, place it in location, and plug the cable into the port marked "TO/FROM OSU POE (RJ45)". WiMAX Telrad CPE 7000 Installation 23

24 Connecting to a Computer, and Power At this point, only connect your computer to the IDU. Connect the customer's equipment only after activating the service. 1. To connect your computer (required if you are using the Web Management Interface alignment option): A. Plug one end of the supplied Ethernet cable into the Ethernet port on the IDU POE adapter. This is the port with the computer icon. Plug the other end into the Ethernet port on your computer. 2. Plug the AC adapter into a 120VAC power source. You are ready to align the ODU. WiMAX Telrad CPE 7000 Installation 24

25 5. Aligning the Telrad CPE 7000 This chapter explains how to align the Telrad CPE 7000 with a base station and verify that the signal quality is within acceptable limits. Rescanning for Base Stations When the Telrad CPE 7000 powers up, it scans for base stations and registers with the base station that provides the highest quality signal. If you move or redirect the ODU, the CPE generally remains registered with the original base station. Before beginning alignment, you must force the CPE to rescan for base stations. This is the only way to ensure that the CPE is registered with the best base station at its current location and direction. WiMAX Telrad CPE 7000 Installation 25

26 You must force the CPE to rescan for base stations anytime the CPE has been powered up and then moved to another location, or pointed in another direction at the same location. Simply power cycle the CPE to cause the unit to rescan. You can also use the Web Management Interface (WMI) to force the CPE to rescan. To use the WMI, the computer must first be configured for Dynamic Host Configuration Protocol, or DHCP. If you did not configure your computer for DHCP during site preparation, you must do so now. Refer to the DHCP topic of the Preparing for the Site Visit chapter. When you have configured your computer for DHCP: 1. Point the ODU in the new direction. 2. Connect the Cat5e cable that is part of the POE adapter to the Ethernet port on the computer. This physical connection corresponds to the Local Area Connection access type that you configured to use DHCP. To do this, first unplug the POE adapter and power down your computer, connect the Ethernet cable, then plug the adapter back in and start the computer. 3. At the computer, open a web browser. 4. In the browser address bar, enter: The WMI login window opens. 5. For User Name, enter: admin For Password, enter: xplornet4g 6. Click Login. The following window opens. WiMAX Telrad CPE 7000 Installation 26

27 7. Click the Power Cycle button (highlighted by red box in above diagram) 8. The CPE reboots and takes 2 minutes and 10 seconds to rescan. WiMAX Telrad CPE 7000 Installation 27

28 WMI State Parameters When power is applied to the ODU, it begins scanning for a base station. When it finds a base station, it starts establishing end-to-end communications through the network. The ODU progresses through several states as end-to-end communications are established. The Mobile Network Status page of the WMI uses the State parameter to show the current state. When you have mounted the ODU and are getting ready to align it, you can use the State value to guide your initial alignment of the ODU. While the ODU is searching for a base station, the State parameter value is generally scanning. When the ODU finds a base station, the State value changes and goes through a sequence of values; see the chart below. When end-to-end communications are established, the State changes to the final value of OPERATIONAL. To monitor the State value, if you have not already configured your computer for Dynamic Host Configuration Protocol, or DHCP, you must do so now. Refer to the DHCP topic in the Preparing for the Site Visit chapter. To monitor the State value: 1. At the computer, open a web browser. 2. In the browser address bar, enter: WiMAX Telrad CPE 7000 Installation 28

29 The WMI login window opens. 3. For Username, enter: admin For Password, enter: xplornet4g 4. Click OK. The Status page opens. 5. Click Mobile Network The Status window opens. 6. If the ODU has been moved since opening the WMI, rescan for base stations as described in the Rescanning for Base Stations procedure. 7. At the ODU, adjust the position of the ODU until the value of State is OPERATIONAL. If you cannot achieve an OPERATIONAL state: A. Verify the direction to the base station. B. Verify the line of sight path to the base station. C. Verify all cable connections and integrity. D. If necessary, call the Dealer Support Group to verify network availability: State Scanning DL Synchronization UL Acquisition Ranging Capabilities Negotiation Authorization Registration Operational Idle Aborted Description Part of the scanning process Part of the scanning process Part of the scanning process Part of the scanning process Part of the scanning process Part of the registering process Part of the registering process CPE is connected to the base station and is operational CPE is connected to the base station; however no data is being passed. Idle state will change to Operational once data is passed over the Air Link. Part of the scanning process WiMAX Telrad CPE 7000 Installation 29

30 Alignment Options The Telrad CPE 7000 provides two options for aligning the ODU: LEDs on the ODU WMI We look at each of these in detail in the next topics. LEDs WiMAX Telrad CPE 7000 Installation 30

31 WMI WiMAX Telrad CPE 7000 Installation 31

32 Alignment using the ODU LEDs 4G Status LED: Link Status When CPE is connected to a base station the LEDs indicate the CINR level 4G 1 Red Steady On CINR < 8dB 4G 2 Red/Yellow Steady On 8dB <CINR < 24dB 4G 3 Red/Yellow /Green Steady On 24dB <= CINR To align the ODU using the LEDs: 1. At the IDU, plug the AC adapter into a live 120VAC outlet. 2. At the ODU, confirm the line of sight path to the base station. 3. Direct the ODU towards the base station. 4. Rescan for base stations as described in the Rescanning for Base Stations procedure. 5. Observe the LEDs. Once the start-up built in test (BIT) has completed and the ODU has connected to a base station, the bottom three Link Status LEDs on the ODU indicate the carrier to interference-plus-noise ratio (CINR) of the signal from the base station. The above table shows the CINR level measured by each LED. 6. While monitoring the LEDs, move the ODU to the position where the green LED is on. (This indicates the best serving base station.) WiMAX Telrad CPE 7000 Installation 32

33 7. When you have found this position, tighten the ODU to the pole. You now need to verify that signal strength and quality are acceptable. The information you need to do this is provided later in this chapter, under Acceptance. WiMAX Telrad CPE 7000 Installation 33

34 Alignment using the WMI If you have not already configured your computer for DHCP during site preparation, you must do so now. Refer to the DHCP topic of the Preparing for the Site Visit chapter. When the computer is configured for DHCP: 1. If you are not already logged in to the WMI, open a web browser at the computer. 2. In the browser address bar, enter: The WMI login window opens. 3. For User Name, enter: admin For Password, enter: xplornet4g 4. Click OK. The Status page opens. 5. Click Mobile Network. The Status page opens WiMAX Telrad CPE 7000 Installation 34

35 6. Click the Auto button (at the bottom of the window). This causes the values to refresh every 5 seconds. 7. At the ODU, confirm the line of sight to the base station. 8. Direct the ODU towards the base station. 9. Rescan for base stations as described in the Rescanning for Base Stations procedure. 10. While monitoring the RSSI and CINR Reuse 1 levels, move the ODU to the position that provides the best levels. For RSSI, as an example: -50dBm is better than -60dBm. For CINR, as an example: 20dB is better than 15dB. Remember that the RSSI and CINR Reuse 1 values take a few seconds to refresh. 11. When you have found the best position, tighten the ODU to the platform. You now need to verify that signal strength and quality are acceptable. The information you need to do this is provided later in this chapter, under Acceptance. WiMAX Telrad CPE 7000 Installation 35

36 Quality of Installation Parameters All Xplornet Internet services are offered through a number of rate plans, with each rate plan tailored for a specific user group (for examples, EOWC or FBS). Rate plans are delivered at different bandwidths depending on the network infrastructure serving the customer. Each rate plan also offers several packages to provide flexibility in the service offerings for the rate plan. Quality of Installation (QoI) parameters has been defined for the WiMAX service and acceptable values for the QoI parameters are set for each rate plan. A service is unacceptable if a measured value fails to meet the specified value. The QoI parameters are provided as an appendix to the WiMAX Customer Premise Equipment Installation guide. One of the site preparation activities was to download the guide to your computer and to record your customer s Program and Rate Plan. You need to find your customer s rate plan in the QoI appendix now. WiMAX Program Name Channel Bandwidth QoI Parameter Rate Plan 1 Rate Plan 2 Rate Plan 3 Rate Plan 4 Minimum DL RSSI Level (dbm) Maximum DL RSSI Level (dbm) Minimum DL CINR Level (db) Minimum Downlink Level Minimum Uplink Level WiMAX Telrad CPE 7000 Installation 36

37 Acceptance, Part 1 If you have not already configured your computer for DHCP during site preparation, you must do so now. Refer to the DHCP topic in the Preparing for the Site Visit chapter. To determine the quality of installation: 1. Have the applicable QoI parameters available 2. In the browser address bar, enter: The WMI login window opens. 3. For User Name, enter: admin For Password, enter: xplornet4g 4. Click OK. The System Status page opens. 5. Click on Mobile Network. The Mobile Network Status page opens 6. At the ODU, point the ODU along the line of sight to the base station you chose during your site survey. WiMAX Telrad CPE 7000 Installation 37

38 7. Rescan for base stations as described in the Rescanning for Base Stations procedure. 8. At the WMI, check the Bandwidth parameter: 5000 khz is a 5MHz channel, 10000kHz is a 10MHz channel. 9. Also check the Center Frequency. 10. Locate the QoI parameters: The CINR Reuse 1 parameters. 11. Click the Auto button (at the bottom of the window). This causes the Mobile Network Status values to refresh every 5 seconds. 12. Return to the WMI browser window. 13. While monitoring the CINR Reuse 1 level, move the ODU to the position that provides the best levels. 14. Compare the levels with the minimum acceptable levels for the rate plan to which the customer has subscribed. Remember to select the correct bandwidth channel. 15. If the levels are as good as or better than the minimums, continue. Note: For CINR, as an example: 20 is better than 15. For RSSI, as an example: -50 is better than If the levels do not meet the minimum, follow the troubleshooting instructions provided in Part 2 of this procedure. 17. Is the RSSI level better than -40? (As an example, -39 is better than -40.) If yes, change the alignment so that the RSSI falls to -40 or slightly (for example, -41 or -42). This is necessary to avoid receiver saturation. In most cases, tilting the ODU down slightly resolves this situation. Do not rotate the ODU to the side to reduce RSSI as this can cause interference with neighboring base stations or CPEs. WiMAX Telrad CPE 7000 Installation 38

39 Rescan for base stations and repeat the alignment and acceptance procedures. If the quality is still unacceptable, or there is only one base station, contact the Dealer Support Group: or WiMAX Telrad CPE 7000 Installation 39

40 Identifying the Base Station To identify the base station that the CPE is registered to: 1. Login to the WMI as admin. The System Status window opens. 2. Click the Mobile Network Status tab. The Mobile Network Status window opens. 3. In the Mobile Network section, locate the BSID number. BSID stands for Base Station Identifier. The first six digits of the BSID are the same for all Xplornet base stations. The seventh to tenth digits identify the site. The last two digits identify the sector. Digits can be letters or numbers. 4. Download and open the Base Station ID list from Xplornet University Library section on WiMAX: 5. Scan the BSID column until you find the BSID. WiMAX Telrad CPE 7000 Installation 40

41 6. Connecting Your Customer s Computer to the CPE Once you have activated the service, you are only obligated to establish a connection to the Internet on your own computer and demonstrate connectivity to your customer. Connecting your customer's computer to the IDU and confirming Internet access are optional activities. They do promote goodwill but if your customer has a complex network or very old equipment, you may not be able to realize a positive outcome. If you choose to connect the customer s computer: 1. Ensure that the customer's computer is configured for DHCP operation. If it is not, refer to the DHCP topic of the Preparing for the Site Visit chapter. 2. When you have configured the computer for DHCP, plug the supplied Ethernet cable into the customer's computer and the IDU. 3. At the computer, open a web browser. 4. In the browser address bar, enter: The WMI login window opens. WiMAX Telrad CPE 7000 Installation 41

42 5. For User Name, enter: admin For Password, enter: xplornet4g Do not use the Installer-only login credentials with the customer s computer. 6. Click OK. The System Status window opens. If the parameters have values, the service is operating normally. If you choose to test for Internet access: 7. Open another browser window and try to surf the web. Use a web page with frequently updated content to ensure that the browser is actually surfing the web and not accessing old content saved on the computer. Remember at this time you will only be able to surf whitelisted pages. Make sure to give the customer the Customer Activity Centre Leave Behind hand out. If you can surf, you are done. If you cannot, and you are not familiar with relevant troubleshooting procedures, refer the customer to Xplornet Technical Support: ; support@xplornet.com. WiMAX Telrad CPE 7000 Installation 42

The Telrad LTE CPE 7000 Outdoor Customer Premise Equipment Installation

The Telrad LTE CPE 7000 Outdoor Customer Premise Equipment Installation The Telrad LTE CPE 7000 Outdoor Customer Premise Equipment Installation Version: 1.0 Publication Date: 12-Aug-14 Revision History Date Version Description of Changes 12-Aug 14 1.0 First release. 03-Sept-14

More information

R1 Extender. Quick Installation Guide

R1 Extender. Quick Installation Guide R1 Extender Quick Installation Guide V1.0 January 2009 Copyright Copyright 2008 all rights reserved. No part of this publication may be reproduced, adapted, stored in a retrieval system, translated into

More information

R2 Extender. Quick Installation Guide

R2 Extender. Quick Installation Guide R2 Extender Quick Installation Guide V 2.1.9 October 2009 Chapter 1 Introduction Page 1 Copyright Copyright 2009 all rights reserved. No part of this publication may be reproduced, adapted, stored in a

More information

Ruckus Wireless ZoneFlex g Outdoor Access Point. Getting Started Guide. Part Number (Revision B) Published October 2009

Ruckus Wireless ZoneFlex g Outdoor Access Point. Getting Started Guide. Part Number (Revision B) Published October 2009 Ruckus Wireless ZoneFlex 2741 802.11g Outdoor Access Point Getting Started Guide Part Number 800-70180-001 (Revision B) Published October 2009 www.ruckuswireless.com Contents 1 About This Getting Started

More information

R2 BaseStation. Quick Installation Guide

R2 BaseStation. Quick Installation Guide R2 BaseStation Quick Installation Guide V 1.0 March 2009 Page 1 Copyright Copyright 2009 all rights reserved. No part of this publication may be reproduced, adapted, stored in a retrieval system, translated

More information

QUICK START GUIDE FOR THE TRANZEO WIRELESS TR-CPE90

QUICK START GUIDE FOR THE TRANZEO WIRELESS TR-CPE90 QUICK START GUIDE FOR THE TRANZEO WIRELESS TR-CPE90 REVISION 1.3 FIRMWARE 8.0.2 JANUARY 3, 2006 FCC Information This equipment has been tested and found to comply with the limits for a Class B digital

More information

AN-80i. Advanced Broadband Wireless Infrastructure Solutions. Quick Install Guide

AN-80i. Advanced Broadband Wireless Infrastructure Solutions. Quick Install Guide Advanced Broadband Wireless Infrastructure Solutions Quick Install Guide 1 Safety Notices 1. Do not exceed the described limits on product labels. Position power cords to avoid damage. Do not overload

More information

QUICK START GUIDE FOR THE TRANZEO WIRELESS TR CPE-80

QUICK START GUIDE FOR THE TRANZEO WIRELESS TR CPE-80 QUICK START GUIDE FOR THE TRANZEO WIRELESS TR CPE-80 REVISION 1.1 THURSDAY, NOVEMBER 04, 2004 FCC Information This equipment has been tested and found to comply with the limits for a Class A digital devices

More information

AW58100HTP-PAIR USER S MANUAL

AW58100HTP-PAIR USER S MANUAL USER S MANUAL 5.8 GHz Outdoor 100 Mbps Ethernet Point-to-Point Radio System Industrial-grade, long-range wireless Ethernet systems AvaLAN W I R E L E S S The AW58100HTP-PAIR consists of two AW58100HTS

More information

LED Indicators on the Device. No LED State Description. No power to AP. Green On

LED Indicators on the Device. No LED State Description. No power to AP. Green On SP220-C02 802.11ac Outdoor Access Point Quick Setup Guide This Quick Setup Guide provides step-bystep instructions on how to set up your Outdoor Access Point. After completing the steps described in this

More information

ALTAI C1N SUPER WIFI CPE INSTALLATION GUIDE. Version 1.0 Date: September, Altai Technologies Ltd. All rights reserved

ALTAI C1N SUPER WIFI CPE INSTALLATION GUIDE. Version 1.0 Date: September, Altai Technologies Ltd. All rights reserved ALTAI C1N SUPER WIFI CPE INSTALLATION GUIDE Version 1.0 Date: September, 2013 Copyright 2007 Altai Technologies Limited ALL RIGHTS RESERVED. Altai Technologies Limited Unit 209, 2/F, East Wing, Building

More information

Ruckus Wireless ZoneFlex 7762 Dual Band n Outdoor Access Point. Installation Guide

Ruckus Wireless ZoneFlex 7762 Dual Band n Outdoor Access Point. Installation Guide Ruckus Wireless ZoneFlex 7762 Dual Band 802.11n Outdoor Access Point Installation Guide Part Number 800-70216-001 (Revision H) Published November 2011 www.ruckuswireless.com Contents 1 About This Installation

More information

AlphaGateway SMG-01PE Quick Start Guide

AlphaGateway SMG-01PE Quick Start Guide AlphaGateway SMG-01PE Quick Start Guide 9 Power-Passing Tap 2 AlphaGateway SMG 5 1 8 6 3 4 7 PoE Devices Security Camera Wi-Fi Radio 1. 1 RF Connector Test Port A -20dB test port allowing measurement of

More information

Quick Start Guide BEC G/LTE Outdoor Router

Quick Start Guide BEC G/LTE Outdoor Router Quick Start Guide BEC 6900 4G/LTE Outdoor Router RidgeWave 6900 4G/LTE Outdoor Router PLEASE READ THE QUICK START GUIDE AND FOLLOW THE STEPS CAREFULLY. THIS QUICK START GUIDE WILL HELP YOU INSTALL THE

More information

AW58300HTA AW58300HTS USER S MANUAL

AW58300HTA AW58300HTS USER S MANUAL AW58300HTA AW58300HTS USER S MANUAL 5.8 GHz Outdoor 300 Mbps Wireless Ethernet Access Point and Subscriber Unit Radios Industrial-grade, long-range wireless Ethernet systems AvaLAN W I R E L E S S The

More information

AW58300HTP-PAIR USER S MANUAL

AW58300HTP-PAIR USER S MANUAL USER S MANUAL 5.8 GHz Outdoor 300 Mbps Ethernet Point-to-Point Radio System Industrial-grade, long-range wireless Ethernet systems AvaLAN W I R E L E S S The AW58300HTP-PAIR consists of two AW58300HTS

More information

NetCommWireless. Quick Start Guide NTC-30 Series - Outdoor WiFi Router

NetCommWireless. Quick Start Guide NTC-30 Series - Outdoor WiFi Router NetCommWireless Quick Start Guide NTC-30 Series - Outdoor WiFi Router NetCommWireless Let s get this show on the road You must be excited to get started with your Outdoor WiFi Router. If all goes to plan,

More information

EAP110-Outdoor. Installation Guide. 300Mbps Wireless N Outdoor Access Point

EAP110-Outdoor. Installation Guide. 300Mbps Wireless N Outdoor Access Point EAP110-Outdoor Installation Guide 300Mbps Wireless N Outdoor Access Point Contents Overview 1 Typical Network Topology 4 Lightning and ESD Protection 5 Hardware Installation Mount EAP Connect Cables Power

More information

ZN-7100-DE500-G V ac Wireless Access Point Quick Setup Guide

ZN-7100-DE500-G V ac Wireless Access Point Quick Setup Guide Bottom View ZN-7100-DE500-G V4 802.11ac Wireless Access Point Quick Setup Guide This Quick Setup Guide provides step-bystep instructions on how to set up your ZN- 7100-DE500-G V4 Wireless Access Point.

More information

CAP300-Outdoor. Installation Guide. 300Mbps Wireless N Outdoor Access Point

CAP300-Outdoor. Installation Guide. 300Mbps Wireless N Outdoor Access Point CAP300-Outdoor Installation Guide 300Mbps Wireless N Outdoor Access Point Contents Overview 1 Typical Network Topology 4 Lightning and ESD Protection 5 Hardware Installation Mount CAP Connect Cables Power

More information

Installing the Camera

Installing the Camera CHAPTER 2 This chapter provides information and instructions for installing the Cisco Video Surveillance PTZ IP camera, and includes the following topics: Installation Guidelines, page 2-1 Warnings Before

More information

QUICK START GUIDE. NetCommWireless. Outdoor Dual Band WiFi N Access Point NP731

QUICK START GUIDE. NetCommWireless. Outdoor Dual Band WiFi N Access Point NP731 QUICK START GUIDE Outdoor Dual Band WiFi N Access Point NP731 WELCOME Thank you for choosing a NetComm Wireless NP731 Outdoor Dual Band WiFi N Access Point. This guide will help you set up, connect and

More information

Ruckus WirelessTM ZoneFlexTM n Wireless Bridge User Guide Part Number rev C Published October 2011

Ruckus WirelessTM ZoneFlexTM n Wireless Bridge User Guide Part Number rev C Published October 2011 Ruckus Wireless TM ZoneFlex TM 7731 802.11n Wireless Bridge User Guide Part Number 800-70285-001 rev C Published October 2011 www.ruckuswireless.com Contents About This Guide Document Conventions.................................................

More information

TASER Axon Dock Installation Manual IMPORTANT SAFETY INSTRUCTIONS

TASER Axon Dock Installation Manual IMPORTANT SAFETY INSTRUCTIONS TASER Axon Dock Installation Manual IMPORTANT SAFETY INSTRUCTIONS Read all warnings and instructions. Save these instructions. The most up-to-date warnings and instructions are available at www.taser.com

More information

BreezeMAX Wi² and BreezeACCESS Wi² Quick Installation Guide

BreezeMAX Wi² and BreezeACCESS Wi² Quick Installation Guide This Quick Installation Guide is intended for experienced installers. For more information refer to the relevant sections in the BreezeMAX Wi² and BreezeACCESS Wi² System Manual. Wi² Package Content Check

More information

ZN-7100-DE500-G V ac Wireless Access Point Quick Setup Guide

ZN-7100-DE500-G V ac Wireless Access Point Quick Setup Guide Bottom View ZN-7100-DE500-G V2 802.11ac Wireless Access Point Quick Setup Guide This Quick Setup Guide provides step-bystep instructions on how to set up your ZN- 7100-DE500-G V2 Wireless Access Point.

More information

Next Gen Sarix Enhanced IBE Series Bullet Cameras

Next Gen Sarix Enhanced IBE Series Bullet Cameras Next Gen Sarix Enhanced IBE Series Bullet Cameras Installation Manual C1334M 12/16 1 Contents Important Notices... 3 Regulatory Notices... 3 Radio and Television Interference... 3 Korean Class A EMC...

More information

Mounting Accessory Guide

Mounting Accessory Guide Apr. 12 2010 Table of Contents Mounting Accessory Guide 1 Overview 5 Introduction... 5 Types of Mounting Methods... 5 Surface... 5 Wall... 5 L-Type Wall Mount (PMAX-0308) 6 Heavy Duty Wall Mounts (PMAX-0305

More information

Ruckus Wireless ZoneFlex g Outdoor Access Point. User Guide. Part Number Published January

Ruckus Wireless ZoneFlex g Outdoor Access Point. User Guide. Part Number Published January Ruckus Wireless ZoneFlex 2741 802.11g Outdoor Access Point User Guide Part Number 800-70205-001 Published January 2009 www.ruckuswireless.com Contents About This Guide Document Conventions.................................................

More information

EWS660AP. Quick Installation Guide

EWS660AP. Quick Installation Guide Package contents - Managed indoor access point - Power adapter - RJ-45 Ethernet cable - Mounting bracket - Mounting kit - T-Rail mounting kit IP Adress configuration Step 1: Once your computer is on, ensure

More information

Quick Installation Guide

Quick Installation Guide 4.9-5.8GHz MIMO Bridge Point to Point Kit Package Contents: Two Netkrom AIRNET Outdoor Bridge Units Two Mounting brackets (include: 2 Wall/ Pole mounting system and 4 screw nuts) Two PoE Injectors Two

More information

Quick Installation Guide

Quick Installation Guide Quick Installation Guide AIRNET 54 Mb CPE Bridge Point to Point Kit Series Package Contents: 2 Netkrom CPE units Two Mounting bracket include: 2 stainless steel U-Bolt, 2 mounting brackets, 2 pipe Brackets

More information

Sarix Professional IMP Series 3.75 Indoor Dome. Quick Start Guide IMP121-1IS IMP221-1IS IMP321-1IS IMP521-1IS C2291M-B-EN (12/16)

Sarix Professional IMP Series 3.75 Indoor Dome. Quick Start Guide IMP121-1IS IMP221-1IS IMP321-1IS IMP521-1IS C2291M-B-EN (12/16) Sarix Professional IMP Series 3.75 Indoor Dome Quick Start Guide IMP121-1IS IMP221-1IS IMP321-1IS IMP521-1IS C2291M-B-EN (12/16) Sarix Professional IJP Series 2 Micro Indoor Dome Quick Start Guide IJP121-1IS

More information

3G/4G OUTDOOR ROUTER Instruction Manual

3G/4G OUTDOOR ROUTER Instruction Manual 3G/4G OUTDOOR ROUTER Instruction Manual SKU: MRE401 1. Introduction With an integrated mobile modem and Wi-Fi amplifier, the MRE401 outdoor router can receive 3G/4G mobile phone signals and establish a

More information

INSTALL INSTRUCTIONS RSXMR-9886-P-48

INSTALL INSTRUCTIONS RSXMR-9886-P-48 INSTALL INSTRUCTIONS RSXMR-9886-P-48 Installation Instructions RSXMR-9886-P-48 (CEQ. 20194) INSTALL INSTRUCTIONS RSXMR-9886-P-48 Contents Section Description Page 1 Copyright 2 1.1 Disclaimer 2 1.2 Warnings

More information

2M IR Mini Dome Quick Installation Guide

2M IR Mini Dome Quick Installation Guide 1 2M IR Mini Dome Quick Installation Guide Please follow the installation steps below to set up 2M IR Mini Dome IP Camera. Check the package contents against the list below. See P.1 Physical overview.

More information

Nevco Message Center Installation Manual Retain this manual in your permanent file. 08/27/ Rev. C

Nevco Message Center Installation Manual Retain this manual in your permanent file. 08/27/ Rev. C Nevco Message Center Installation Manual Retain this manual in your permanent file. 08/27/2014 135-0144 Rev. C Table of Contents INSTALLATION INSTRUCTIONS... 1 UNPACKING THE EQUIPMENT... 1 MESSAGE CENTER

More information

Installation Notes TII Model 341 Protector

Installation Notes TII Model 341 Protector Installation Notes TII Model 341 Protector (ATT-IS PEC 32918) for MERLIN Communications System In Range Out of Building (IROB) Station Installation By Trained Technician Only WARNING: Failure to follow

More information

IS-DM220/IR/HB IS-DM220

IS-DM220/IR/HB IS-DM220 IS-DM220/IR/HB IS-DM220 Installation Guide Indoor/Outdoor Ver. 1.2 00P6NX223ZXSEA2 Table of Contents 1. Indoor Camera Installation... 3 1.1 Hard Ceiling... 3 1.2 In-Ceiling (T-Bar) Mounting... 13 1.3 4S

More information

ReachFree ID Installation Instructions for Wash Select II. Unitec

ReachFree ID Installation Instructions for Wash Select II. Unitec ReachFree ID Installation Instructions for Wash Select II Unitec www.startwithunitec.com Proprietary Information and Materials of Unitec Inc. Such proprietary information and materials may not be disclosed

More information

Ruckus Wireless ZoneFlex 7782 Dual Band n Outdoor Access Point. Installation Guide

Ruckus Wireless ZoneFlex 7782 Dual Band n Outdoor Access Point. Installation Guide Ruckus Wireless ZoneFlex 7782 Dual Band 802.11n Outdoor Access Point Installation Guide Part Number 800-70387-001 Rev 01 Published July 2012 www.ruckuswireless.com Contents 1 About this Installation Guide.................................................

More information

Model#: IN-DO3MIRF 3MP Outdoor Dome with True Day/Night, IR, Basic WDR, Fixed lens

Model#: IN-DO3MIRF 3MP Outdoor Dome with True Day/Night, IR, Basic WDR, Fixed lens Model#: IN-DO3MIRF 3MP Outdoor Dome with True Day/Night, IR, Basic WDR, Fixed lens Hardware User Manual (PoE) 2013/03/06 Table of Contents Precautions... 3 Introduction... 4 Package Contents... 4 Safety

More information

Broadband Wireless Radio Platform. Quick Start Guide

Broadband Wireless Radio Platform. Quick Start Guide RDL-3000 Broadband Wireless Radio Platform Quick Start Guide This guide is provided to aid initial deployment of RDL-3000 systems. Refer to the RDL-3000 User Manual and the RDL-3000 Installation Guidelines

More information

MULTIBAND Dual Radio V4

MULTIBAND Dual Radio V4 Dual Radio V4 WI FI Compatibility Speed Package Contents: Multiband Dual Radio v4 Mounting Bracket (Include: 2 stainless & steel U-Bolt, 1 Bracket and 4 screw nuts) 100-240VAC 48VDC, 350 ma PoE Injector

More information

MASTERLINE Ultimate Hybrid High Voltage 4/12 (MLUH HV 4/12) blunt cut at BTS side

MASTERLINE Ultimate Hybrid High Voltage 4/12 (MLUH HV 4/12) blunt cut at BTS side INSTALLATION MANUAL HUBER+SUHNER AG Fiber Optics MASTERLINE Ultimate Hybrid High Voltage 4/12 (MLU HV 4/12) blunt cut at BTS side DOC-0000803885 Rev A June 18, 2018 Page 1 of 12 (MLUH HV 4/12) blunt cut

More information

Installing a Power over Ethernet injector

Installing a Power over Ethernet injector Installing a Power over Ethernet injector AlphaEclipse StreetSmart and RoadStar signs The instructions in this document explain how to install/replace a Power over Ethernet (PoE) injector in a StreetSmart

More information

Perle IDS-108F(XT) Unmanaged 10/100 Ethernet Switches. Installation Guide. P/N (Rev G)

Perle IDS-108F(XT) Unmanaged 10/100 Ethernet Switches. Installation Guide. P/N (Rev G) Perle IDS-108F(XT) Unmanaged 10/100 Ethernet Switches Installation Guide P/N 5500339-10 (Rev G) Overview This document contains instructions necessary for the installation and operation of the Perle IDS-108F

More information

Hardware overview. Package contents MSM710, documentation, power supply, self-adhesive rubber feet.

Hardware overview. Package contents MSM710, documentation, power supply, self-adhesive rubber feet. In MSM710 Controller Quickstart This Quickstart applies to both the MSM710 Access Controller (J9328A) and the MSM710 Mobility Controller (J9325A). This Quickstart introduces the HP ProCurve Networking

More information

SKYLEVEL INSTALLATION Manual

SKYLEVEL INSTALLATION Manual SKLEVEL INSTALLATION Manual Southwest Windpower, Inc. 80 West Route 66 Flagstaff, Arizona 8600 USA Phone: 928-779-9463 Fax: 928-779-485 www.skystreamenergy.com June 2009 Southwest Windpower, Inc. All Rights

More information

AW5800HTP-PAIR USER S MANUAL

AW5800HTP-PAIR USER S MANUAL USER S MANUAL 5.8 GHz Wireless Ethernet Bridge With Integrated Antennas Industrial-grade, long-range wireless Ethernet systems AvaLAN W I R E L E S S User s Manual Thank you for your purchase of the AW5800HTP-PAIR

More information

TECHKNOW, INC. Kiosk Order Confirmation System INSTALLATION MANUAL. Revision Date: July 11, 2012 Part # Version 3.2

TECHKNOW, INC. Kiosk Order Confirmation System INSTALLATION MANUAL. Revision Date: July 11, 2012 Part # Version 3.2 document Page 1 of 18 TECHKNOW, INC Kiosk Order Confirmation System INSTALLATION MANUAL Revision Date: July 11, 2012 Part # Version 3.2 Techknow, Inc. 393 Mayfield Road Duncan, SC 29334 www.gotechknow.com

More information

EAN Setup Guide. Global Telecom Indoor/Outdoor Unit SUPPORT: 1(888) OR

EAN Setup Guide. Global Telecom Indoor/Outdoor Unit SUPPORT: 1(888) OR EAN Setup Guide Global Telecom Indoor/Outdoor Unit SUPPORT: 1(888)458-8668 OR EANSUPPORT@NMU.EDU Table of Contents Box Contents.. 2 Getting Started... 3 Hardware Overview.. 3 Indoor Setup.. 4 Outdoor Setup...

More information

EVOLVE1-M MONITOR ARM

EVOLVE1-M MONITOR ARM EVOLVE1-M MONITOR ARM EVOLVE1-M Rev A 2/17 Model EVOLVE1-M-SLV Model EVOLVE1-M-BLK Model EVOLVE1-M-WHT ASSEMBLY AND ADJUSTMENT EVOLVE1-M MONITOR ARM PARTS AND TOOLS PLEASE REVIEW these instructions before

More information

Gigabit Ethernet Switch. Quick Installation Guide MS400834M

Gigabit Ethernet Switch. Quick Installation Guide MS400834M Gigabit Ethernet Switch Quick Installation Guide MS400834M Version 1.0 Gigabit Ethernet Switch Quick Installation Guide II Table of Contents Table of Contents... ii 1. Introduction... 1 1.1 Overview...

More information

Yeastar S100 VoIP PBX

Yeastar S100 VoIP PBX Yeastar S100 VoIP PBX Installation Guide Version: 1.1 Date: 2016/7/6 Content Welcome...3 Before You Start..4 Package Contents.4 Expansion Board 4 Yeastar S100 Overview...5 LED Indicators and Ports..6 Installation...8

More information

Nexxt Solutions - NexxtGate150 Access Point. Quick Installation Guide

Nexxt Solutions - NexxtGate150 Access Point. Quick Installation Guide Quick Installation Guide 1. Introduction Thank you for purchasing the Nexxt Solutions 2.4 GHz High-Power Wireless-N Access Point NexxtGate150. If any of the following items are mismatched, missing or damaged,

More information

QUICK START GUIDE. WK-2x Access Point. WK-2, WK-2-B, WK-2-C / ac Dual Band Access Version 1.1

QUICK START GUIDE. WK-2x Access Point. WK-2, WK-2-B, WK-2-C / ac Dual Band Access Version 1.1 QUICK START GUIDE WK-2x Access Point WK-2, WK-2-B, WK-2-C / 802.11ac Dual Band Access Version 1.1 Contents Package Contents 3 WK-2 Mounting Options 4 WK-2-C Mounting 14 Powering Up the Access Point 22

More information

Terragraph Installation Guide. March 8, 2017 Version 0.3

Terragraph Installation Guide. March 8, 2017 Version 0.3 Terragraph Installation Guide March 8, 2017 Version 0.3 Warnings WARNING: Shock Hazard. May result in serious injury or death. Turn off circuit power at circuit breaker or disconnect power at source receptacle

More information

Replacing the Power Supply

Replacing the Power Supply APPENDIX B This appendix includes information on how to replace the power supply for the Cisco AS550XM universal gateway and contains the following sections: Safety Recommendations, page B-1 Required Tools

More information

Bullet Camera Installation in an Outdoor Enclosure

Bullet Camera Installation in an Outdoor Enclosure Bullet Camera Installation in an Outdoor Enclosure This document explains how to install a Bullet Camera into an outdoor enclosure. Step 1: Install the Wi-Fi Antenna (Optional) If you will be installing

More information

Quick Start Guide. Mounting the Essential Plus and Elite

Quick Start Guide. Mounting the Essential Plus and Elite Quick Start Guide Congratulations on purchasing an Essential Plus or Elite access control system. This Quick Start Guide provides simple instructions on how to get the system up and running. For more detailed

More information

DIGITAL OBSERVATION GUARD LOW PROFILE PAN TILT KIT USER MANUAL

DIGITAL OBSERVATION GUARD LOW PROFILE PAN TILT KIT USER MANUAL DIGITAL OBSERVATION GUARD LOW PROFILE PAN TILT KIT USER MANUAL Version 2.1 June 4, 2013 0 Table of Contents Low Profile Pan Tilt Kit Description... 3 Low Profile Pan Tilt Unit Basic Operation... 4 Mounting

More information

Quick Installation Guide

Quick Installation Guide Outdoor AP/Bridge Package Contents: Airnet Outdoor Access Point Mounting Bracket (Include: 2 Mounting Brackets and 4 screw nuts) PoE Injector Power Cable RJ45 Waterproof Connector System CD-ROM Quick Hardware

More information

SAP Series IP Clock. Installation Manual V7.2. P. (+1) F. (+1)

SAP Series IP Clock. Installation Manual V7.2. P. (+1) F. (+1) Installation Manual V7. SAP Series IP Clock Current as of May 08 The Sapling Company, Inc. SAP Series IP Clocks Table of Contents Table of Contents Important Safety Instructions 3 Identify Your Clock 4

More information

ZAVIO Outdoor IR Mini Dome. Quick Installation Guide

ZAVIO Outdoor IR Mini Dome. Quick Installation Guide ZAVIO Outdoor IR Mini Dome Quick Installation Guide 0 Quick Installation Guide Please follow the installation steps below to set up your IP Camera. Check the package contents with the list below. See P.1

More information

SABRE and IOTA are trademarks of Addvalue Communications Pte Ltd.

SABRE and IOTA are trademarks of Addvalue Communications Pte Ltd. Copyright Copyright 2009 Addvalue Communications Pte Ltd. All rights reserved. This publication and its contents are proprietary to Addvalue Communications Pte Ltd. No part of this publication may be reproduced

More information

Remote RMM-1400 Intelligent Remote Site Management Device. Installation Guide

Remote RMM-1400 Intelligent Remote Site Management Device. Installation Guide Remote RMM-1400 Intelligent Remote Site Management Device Guide INSTALLATION GUIDE Westell Technologies Part # 030-300645 Rev. A Copyright 2015 by Westell Technologies. All Rights Reserved. Westell, Kentrox

More information

Model 1650 WiFi Wireless Setup Using Windows

Model 1650 WiFi Wireless Setup Using Windows Model 1650 WiFi Wireless Setup Using Windows WiFi wireless overview Bridge (receiver) Access point (transmitter) Rear view of sign If multiple signs are present each sign requires a WiFi Bridge unit but

More information

Flat Surfaced Ceiling Mounted Exterior Dome (Face Down) IN-DO2MIRVSLL, IN-DO4MF, IN-DO4M36A, IN-DO1MIRF, IN-DO2MIRF,

Flat Surfaced Ceiling Mounted Exterior Dome (Face Down) IN-DO2MIRVSLL, IN-DO4MF, IN-DO4M36A, IN-DO1MIRF, IN-DO2MIRF, Outdoor Dome Flat Surfaced Ceiling Mounted Exterior Dome (Face Down) Installation Guide For Models: IN-DO2MIRVSLL, IN-DO4MF, IN-DO4M36A, IN-DO1MIRF, IN-DO2MIRF, IN-DO3MIRF, IN-DO5MIRF, IN-DO1MIRV, IN-DO2MIRV,

More information

Further Information can be found at

Further Information can be found at Below is a step by step guide to assembling the Hurricane-Rig. Remember that this is a precision optical instrument. Excessive force can bend critical parts. If treated well it should give many years of

More information

Additional Help For additional installation instructions and videos, please visit our website at What s Included

Additional Help For additional installation instructions and videos, please visit our website at   What s Included Model 400, 40, 40 Additional Help For additional installation instructions and videos, please visit our website at www.current-usa.com What s Included Each LOOP Marine Bundle Kit includes: Item A B C D

More information

InnoMedia Business VoIP ATA Models

InnoMedia Business VoIP ATA Models InnoMedia Business VoIP ATA Models MTA8328-4, MTA8328-8, MTA8328-24 Quick Installation Guide Important Safety Instructions Protective Earthing Protective earthing is used as a safeguard. This equipment

More information

Yeastar S300 VoIP PBX. Installation Guide

Yeastar S300 VoIP PBX. Installation Guide Yeastar S300 VoIP PBX Installation Guide Version 1.0 Jun. 2016 Content Content...2 Welcome.3 Before You Start...4 Package Contents..4 Expansion Board 4 Yeastar S300 Overview.5 LED Indicators and Ports..6

More information

ACCREDITED SOLUTION. EXPLORER CPN Enclosure

ACCREDITED SOLUTION. EXPLORER CPN Enclosure ACCREDITED SOLUTION EXPLORER CPN Enclosure Document Name: EXPLORER - CPN Enclosure Revision: G Introduction: Typical Applications: Product Description: This document describes step-by-step how to mount

More information

Quick Start Guide. AR530&AR550 Series Industrial Switching Routers. Issue: 07 ( ) Part number: HUAWEI TECHNOLOGIES CO.

Quick Start Guide. AR530&AR550 Series Industrial Switching Routers. Issue: 07 ( ) Part number: HUAWEI TECHNOLOGIES CO. Quick Start Guide AR0&AR0 Series Industrial Switching Routers Issue: 0 (0--0) Part number: 0 HUAWEI TECHNOLOGIES CO., LTD Packing List AR0 series industrial switching router (with the product model on

More information

Quick Start Guide. Indoor Stand-Alone Access Point. SunSpot AC1200 and SunSpot N300.

Quick Start Guide. Indoor Stand-Alone Access Point. SunSpot AC1200 and SunSpot N300. Indoor Stand-Alone Access Point SunSpot AC00 and SunSpot N300 The SunSpot N300 and the SunSpot AC00 are single- and dual-band concurrent access points (AP s) respectively. The units are designed to be

More information

Installing the Client Adapter

Installing the Client Adapter CHAPTER 3 This chapter provides instructions for installing the client adapter. The following topics are covered in this chapter: Inserting a Client Adapter, page 3-2 Software, page 3-9 Installing the

More information

PIX 515/515E. PIX 515/515E Product Overview CHAPTER

PIX 515/515E. PIX 515/515E Product Overview CHAPTER CHAPTER 4 PIX 515/515E This chapter describes how to install the PIX 515/515E, and includes the following sections: PIX 515/515E Product Overview Installing a PIX 515/515E PIX 515/515E Feature Licenses

More information

Installation Instructions Revision 1.0 June 2009 Page 1 of 6

Installation Instructions Revision 1.0 June 2009 Page 1 of 6 Bulletin II 103282-EN Installation Instructions Revision 1.0 June 2009 Page 1 of 6 OneBase Dual Band and Twin TMA ETT19V2S12UB/ETW200VS12UB/ETW190VS12UB INTRODUCTION Andrew OneBase Tower Mounted Amplifiers

More information

WiFi Setup Guide. Overview. Before you start

WiFi Setup Guide. Overview. Before you start WiFi Setup Guide Connect WiFi units to Excite, RoadStar, or StreetSmart Signs that use Ooh!Media software Overview Two wireless units come with each WiFi kit. The unit labeled Bridge (receiver) will be

More information

RE.41.LGTW - L-gateway - Modular IoT Base Station Quick Installation Guide

RE.41.LGTW - L-gateway - Modular IoT Base Station Quick Installation Guide RE.41.LGTW - L-gateway - Modular IoT Base Station Quick Installation Guide Author Ivo van Ling Hardware Release 1.0 Quick Install Guide Version QIG_L-gateway_v1.20 Date 29-08-2016 Covering Product code

More information

AC300/AC400 SERIES DYNAMIC BRAKING and ADDITIONAL FORM C RELAY. INSTALLATION INSTRUCTIONS Document Number:

AC300/AC400 SERIES DYNAMIC BRAKING and ADDITIONAL FORM C RELAY. INSTALLATION INSTRUCTIONS Document Number: Minarik Variable Speed AC Motor Drives AC300/AC400 SERIES DYNAMIC BRAKING and ADDITIONAL FORM C RELAY INSTALLATION INSTRUCTIONS Document Number: 250-0297 These instructions apply to models rated: 7.5 25

More information

AP-Ext-N User Manual

AP-Ext-N User Manual AP-Ext-N User Manual Contact Terabeam www.terabeam.com 8000 Lee Highway Falls Church, VA 22042 Office: 703-205-0600 Fax: 703-205-0610 Sales: 1-888-297-9090 MNL-500275-001 Version 1.0 Jun 2005 LIMITED WARRANTY

More information

NetWay1DWP - Outdoor Single Port Hi-PoE Injector NetWay1DWPM - Outdoor Managed Single Hi-PoE Injector I.T.E. 43KC

NetWay1DWP - Outdoor Single Port Hi-PoE Injector NetWay1DWPM - Outdoor Managed Single Hi-PoE Injector I.T.E. 43KC Installation Guide NetWay1DWP - Outdoor Single Port Hi-PoE Injector NetWay1DWPM - Outdoor Managed Single Hi-PoE Injector I.T.E. 43KC Rev. 112713 Overview: Altroni NetWay1DWP Outdoor Single Port Midspan

More information

Quick Setup Guide AMG Skywave III AMG8300S series Wireless Radios Products

Quick Setup Guide AMG Skywave III AMG8300S series Wireless Radios Products Quick Setup Guide AMG Skywave III AMG8300S series Wireless Radios Products The guide is applicable for the following AMG Wireless IP radios: AMG8300S-02-2 2km 300Mbps (Pair) AMG8300S-06-2 6km 300Mbps (Pair)

More information

Installation Guide V290 (Color) This guide provides basic information for Unitronics LCD color touchscreen models V C30B and V T40B.

Installation Guide V290 (Color) This guide provides basic information for Unitronics LCD color touchscreen models V C30B and V T40B. Vision OPLC Installation Guide V290 (Color) This guide provides basic information for Unitronics LCD color touchscreen models V290-19-C30B and V290-19-T40B. General Description Vision OPLCs are programmable

More information

Installation Guide IP-DECT Base Station and IP-DECT Gateway

Installation Guide IP-DECT Base Station and IP-DECT Gateway Installation Guide IP-DECT Base Station and IP-DECT Gateway Contents 1 Introduction... 1 1.1 Abbreviations and Glossary... 1 2 Description... 2 2.1 IPBS1... 2 2.1.1 IPBS1 with Internal Antenna... 2 2.1.2

More information

Outdoor Motorized Dome. Quick Installation Guide 86085A

Outdoor Motorized Dome. Quick Installation Guide 86085A Outdoor Motorized Dome Quick Installation Guide 86085A3340020 Outdoor Motorized Dome Quick Installation Guide Please follow the installation steps below to set up Outdoor Motorized Dome IP Camera. Check

More information

Tactical Weather Station Set-Up Guide 1

Tactical Weather Station Set-Up Guide 1 Tactical Weather Station Set-Up Guide 1 This is a generic overview of a portable WEATHERPAK 3 meter tripod set-up. Your system may not include all of the components listed, or may have different components.

More information

Installation and Maintenance

Installation and Maintenance CHAPTER 4 Installation and Maintenance Revised: April 19, 2010, Introduction This chapter explains how to install a SCE 1000 platform in a rack or in a general tabletop or workbench installation. Additionally,

More information

Connect the drop cable to the ODU (PSU port) and LPU

Connect the drop cable to the ODU (PSU port) and LPU Installing the copper Cat5e Ethernet interface 2 Fit the parts into the body and lightly screw on the gland nut (do not tighten it): Connect the drop cable to the ODU (PSU port) and LPU 1 (a) Plug the

More information

60W Power over Ethernet Waterproof Adapter PoE IEEE BT Single Port Injector for Outdoor Application

60W Power over Ethernet Waterproof Adapter PoE IEEE BT Single Port Injector for Outdoor Application WWW.PHIHONG.COM 60W Power over Ethernet Waterproof Adapter PoE IEEE BT Single Port Injector for Outdoor Application Features Compliant with the IEEE802.3bt Standard Non-Vented Case with Mounting Bracket

More information

MBE Mounts and Adapters

MBE Mounts and Adapters MBE Mounts and Adapters MBE Series en Installation Guide MBE Mounts and Adapters Table of Contents en 3 Table of Contents 1 Important safety instructions 4 2 MBE Series Mounts and Adapters 6 2.1 Unpacking

More information

3G Cell Modem Installation and User Guide

3G Cell Modem Installation and User Guide 3G Cell Modem Installation and User Guide For BaseStation 1000 & BaseStation 3200 Irrigation Controllers in X and XS Cabinets April 24, 2017 Customer Service 1-866-294-5847 Baseline Inc. www.baselinesystems.com

More information

Installation Guide V290 (Color) This guide provides basic information for Unitronics LCD color touchscreen models V C30B and V T40B.

Installation Guide V290 (Color) This guide provides basic information for Unitronics LCD color touchscreen models V C30B and V T40B. Vision OPLC Installation Guide V290 (Color) This guide provides basic information for Unitronics LCD color touchscreen models V290-19-C30B and V290-19-T40B. General Description Vision OPLCs are programmable

More information

M215 (M215-60) Safety

M215 (M215-60) Safety M215 QUICK INSTALL GUIDE M215 (M215-60) Safety Important Safety Information This document contains important instructions to use during installation and maintenance of the Enphase M215 Microinverter. To

More information

Outdoor PTZ. Mounting on the Ceiling Using Pendant Mount. Installation Guide. For Models: I93, I94, I95, I96, KCM /12/03

Outdoor PTZ. Mounting on the Ceiling Using Pendant Mount. Installation Guide. For Models: I93, I94, I95, I96, KCM /12/03 Outdoor PTZ Mounting on the Ceiling Using Pendant Mount For Models: I93, I94, I95, I96, KCM-8211 2013/12/03 Table of Contents Mounting Solutions... 3 Straight Tube Installation Procedures... 4 Step 1:

More information

FortiCam FD40 Mounting Guide

FortiCam FD40 Mounting Guide FortiCam FD40 Mounting Guide 1 FORTINET DOCUMENT LIBRARY http://docs.fortinet.com FORTINET VIDEO GUIDE http://video.fortinet.com FORTINET BLOG https://blog.fortinet.com CUSTOMER SERVICE & SUPPORT https://support.fortinet.com

More information

Oracle <Insert Picture Here>

Oracle <Insert Picture Here> Slide 1 Oracle Slide 2 WZT-6509 version B Sun Fire Nehalem and Westmere Rack-Mount Server Installation and Replacement Welcome to the installation and replacement

More information

3-Port Ethernet over Fiber PoE+ Hardened Switches Installation Guide

3-Port Ethernet over Fiber PoE+ Hardened Switches Installation Guide Embedded 3-Port Ethernet over Fiber PoE+ Hardened Switches Installation Guide Models include: NetWaySP3WP - Includes Fiber Optic SFP 1G, 3-port PoE+ switch and power supply. - NEMA4/4X, IP66 rated Outdoor

More information